Response deprivation, reinforcement, and economics
Allison, James
1993-01-01
Reinforcement of an instrumental response results not from a special kind of response consequence known as a reinforcer, but from a special kind of schedule known as a response-deprivation schedule. Under the requirements of a response-deprivation schedule, the baseline rate of the instrumental response permits less than the baseline rate of the contingent response. Because reinforcement occurs only if the schedule deprives the organism of the contingent response, reinforcement cannot result from any intrinsic property of the contingent response or any property relative to the instrumental response. Two typical effects of response-deprivation schedules—facilitation of the instrumental response and suppression of the contingent response—are discussed in terms of economic concepts and models of instrumental performance. It is suggested that response deprivation makes the contingent response function as an economic good, the instrumental response as currency. PMID:16812695
Semi-empirical and phenomenological instrument functions for the scanning tunneling microscope
NASA Astrophysics Data System (ADS)
Feuchtwang, T. E.; Cutler, P. H.; Notea, A.
1988-08-01
Recent progress in the development of a convenient algorithm for the determination of a quantitative local density of states (LDOS) of the sample, from data measured in the STM, is reviewd. It is argued that the sample LDOS strikes a good balance between the information content of a surface characteristic and effort required to obtain it experimentally. Hence, procedures to determine the sample LDOS as directly and as tip-model independently as possible are emphasized. The solution of the STM's "inverse" problem in terms of novel versions of the instrument (or Green) function technique is considered in preference to the well known, more direct solutions. Two types of instrument functions are considered: Approximations of the basic tip-instrument function obtained from the transfer Hamiltonian theory of the STM-STS. And, phenomenological instrument functions devised as a systematic scheme for semi-empirical first order corrections of "ideal" models. The instrument function, in this case, describes the corrections as the response of an independent component of the measuring apparatus inserted between the "ideal" instrument and the measured data. This linear response theory of measurement is reviewed and applied. A procedure for the estimation of the consistency of the model and the systematic errors due to the use of an approximate instrument function is presented. The independence of the instrument function techniques from explicit microscopic models of the tip is noted. The need for semi-empirical, as opposed to strictly empirical or analytical determination of the instrument function is discussed. The extension of the theory to the scanning tunneling spectrometer is noted, as well as its use in a theory of resolution.
Wind-instrument reflection function measurements in the time domain.
Keefe, D H
1996-04-01
Theoretical and computational analyses of wind-instrument sound production in the time domain have emerged as useful tools for understanding musical instrument acoustics, yet there exist few experimental measurements of the air-column response directly in the time domain. A new experimental, time-domain technique is proposed to measure the reflection function response of woodwind and brass-instrument air columns. This response is defined at the location of sound regeneration in the mouthpiece or double reed. A probe assembly comprised of an acoustic source and microphone is inserted directly into the air column entryway using a foam plug to ensure a leak-free fit. An initial calibration phase involves measurements on a single cylindrical tube of known dimensions. Measurements are presented on an alto saxophone and euphonium. The technique has promise for testing any musical instrument air columns using a single probe assembly and foam plugs over a range of diameters typical of air-column entryways.
Filacchione, Gianrico; Capaccioni, Fabrizio; Altieri, Francesca; Carli, Cristian; Ficai Veltroni, Iacopo; Dami, Michele; Tommasi, Leonardo; Aroldi, Gianluca; Borrelli, Donato; Barbis, Alessandra; Baroni, Marco; Pastorini, Guia; Mugnuolo, Raffaele
2017-09-01
Before integration aboard European Space Agency BepiColombo mission to Mercury, the visible and near infrared hyperspectral imager underwent an intensive calibration campaign. We report in Paper I about the radiometric and linearity responses of the instrument including the optical setups used to perform them. Paper II [F. Altieri et al., Rev. Sci. Instrum. 88, 094503 (2017)] will describe complementary spectral response calibration. The responsivity is used to calculate the expected instrumental signal-to-noise ratio for typical observation scenarios of the BepiColombo mission around Mercury. A description is provided of the internal calibration unit that will be used to verify the relative response during the instrument's lifetime. The instrumental spatial response functions as measured along and across the spectrometer's slit direction were determined by means of spatial scans performed with illuminated test slits placed at the focus of a collimator. The dedicated optical setup used for these measurements is described together with the methods used to derive the instrumental spatial responses at different positions within the 3.5 ° field of view and at different wavelengths in the 0.4-2.0 μm spectral range. Finally, instrument imaging capabilities and Modulated Transfer Function are tested by using a standard mask as a target.
A Study of Morrison's Iterative Noise Removal Method. Final Report M. S. Thesis
NASA Technical Reports Server (NTRS)
Ioup, G. E.; Wright, K. A. R.
1985-01-01
Morrison's iterative noise removal method is studied by characterizing its effect upon systems of differing noise level and response function. The nature of data acquired from a linear shift invariant instrument is discussed so as to define the relationship between the input signal, the instrument response function, and the output signal. Fourier analysis is introduced, along with several pertinent theorems, as a tool to more thorough understanding of the nature of and difficulties with deconvolution. In relation to such difficulties the necessity of a noise removal process is discussed. Morrison's iterative noise removal method and the restrictions upon its application are developed. The nature of permissible response functions is discussed, as is the choice of the response functions used.
Calibration of Herschel SPIRE FTS observations at different spectral resolutions
NASA Astrophysics Data System (ADS)
Marchili, N.; Hopwood, R.; Fulton, T.; Polehampton, E. T.; Valtchanov, I.; Zaretski, J.; Naylor, D. A.; Griffin, M. J.; Imhof, P.; Lim, T.; Lu, N.; Makiwa, G.; Pearson, C.; Spencer, L.
2017-01-01
The SPIRE Fourier Transform Spectrometer on-board the Herschel Space Observatory had two standard spectral resolution modes for science observations: high resolution (HR) and low resolution (LR), which could also be performed in sequence (H+LR). A comparison of the HR and LR resolution spectra taken in this sequential mode revealed a systematic discrepancy in the continuum level. Analysing the data at different stages during standard pipeline processing demonstrates that the telescope and instrument emission affect HR and H+LR observations in a systematically different way. The origin of this difference is found to lie in the variation of both the telescope and instrument response functions, while it is triggered by fast variation of the instrument temperatures. As it is not possible to trace the evolution of the response functions using housekeeping data from the instrument subsystems, the calibration cannot be corrected analytically. Therefore, an empirical correction for LR spectra has been developed, which removes the systematic noise introduced by the variation of the response functions.
Pilot dynamics for instrument approach tasks: Full panel multiloop and flight director operations
NASA Technical Reports Server (NTRS)
Weir, D. H.; Mcruer, D. T.
1972-01-01
Measurements and interpretations of single and mutiloop pilot response properties during simulated instrument approach are presented. Pilot subjects flew Category 2-like ILS approaches in a fixed base DC-8 simulaton. A conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Reduced and interpreted pilot describing functions and remmant are given for pitch attitude, flight director, and multiloop (longitudinal) control tasks. The response data are correlated with simultaneously recorded eye scanning statistics, previously reported in NASA CR-1535. The resulting combined response and scanning data and their interpretations provide a basis for validating and extending the theory of manual control displays.
How discriminating are discriminative instruments?
Hankins, Matthew
2008-05-27
The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.
Planck 2013 results. VII. HFI time response and beams
NASA Astrophysics Data System (ADS)
Planck Collaboration; Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J. J.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Bowyer, J. W.; Bridges, M.; Bucher, M.; Burigana, C.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chary, R.-R.; Chiang, H. C.; Chiang, L.-Y.; Christensen, P. R.; Church, S.; Clements, D. L.; Colombi, S.; Colombo, L. P. L.; Couchot, F.; Coulais, A.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A. A.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K. M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J. E.; Haissinski, J.; Hansen, F. K.; Hanson, D.; Harrison, D.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Hornstrup, A.; Hou, Z.; Hovest, W.; Huffenberger, K. M.; Jaffe, A. H.; Jaffe, T. R.; Jones, W. C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T. S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Laureijs, R. J.; Lawrence, C. R.; Leonardi, R.; Leroy, C.; Lesgourgues, J.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P. M.; Macías-Pérez, J. F.; MacTavish, C. J.; Maffei, B.; Mandolesi, N.; Maris, M.; Marshall, D. J.; Martin, P. G.; Martínez-González, E.; Masi, S.; Massardi, M.; Matarrese, S.; Matsumura, T.; Matthai, F.; Mazzotta, P.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; Noviello, F.; Novikov, D.; Novikov, I.; Osborne, S.; Oxborrow, C. A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polegre, A. M.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G. W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savini, G.; Scott, D.; Shellard, E. P. S.; Spencer, L. D.; Starck, J.-L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sureau, F.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Tavagnacco, D.; Terenzi, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L. A.; Wandelt, B. D.; Yvon, D.; Zacchei, A.; Zonca, A.
2014-11-01
This paper characterizes the effective beams, the effective beam window functions and the associated errors for the Planck High Frequency Instrument (HFI) detectors. The effective beam is theangular response including the effect of the optics, detectors, data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the cosmic microwave background angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: a) the optical response of the telescope and feeds; b) the processing of the time-ordered data and deconvolution of the bolometric and electronic transfer function; and c) the merging of several surveys to produce maps. The time response transfer functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determined to better than 0.5% at each HFI frequency band. Observations of Jupiter and Saturn limit near sidelobes (within 5°) to about 0.1% of the total solid angle. Time response residuals remain as long tails in the scanning beams, but contribute less than 0.1% of the total solid angle. The bias and uncertainty in the beam products are estimated using ensembles of simulated planet observations that include the impact of instrumental noise and known systematic effects. The correlation structure of these ensembles is well-described by five error eigenmodes that are sub-dominant to sample variance and instrumental noise in the harmonic domain. A suite of consistency tests provide confidence that the error model represents a sufficient description of the data. The total error in the effective beam window functions is below 1% at 100 GHz up to multipole ℓ ~ 1500, and below 0.5% at 143 and 217 GHz up to ℓ ~ 2000.
Recommendations for portable supplemental meteorological instrumentation for incident response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, R.M.; Tichler, J.L.
The Nuclear Regulatory Commission (NRC) staff requested technical assistance in recommending portable supplementary meteorological instrumentation which can be deployed to nuclear power plant sites in response to incidents. A supplementary meteorological system (SMS), whose primary function is to collect, analyze and disseminate supplemental meteorological information, is recommended. Instrument specifications are discussed along with maintenance and staffing requirements. A cost evaluation of the components is made. 5 refs., 1 fig.
Buckner, Tyler W; Batt, Katharine; Quon, Doris; Witkop, Michelle; Recht, Michael; Kessler, Craig; Baumann, Kimberly; Hernandez, Grace; Wang, Michael; Cooper, David L; Kempton, Christine L
2018-04-01
Pain, functional impairment, anxiety, and depression associated with joint disease may affect health-related quality of life (HRQoL) in people with hemophilia. To report detailed patient-reported outcomes (PRO) assessments related to HRQoL in participants in the Pain, Functional Impairment, and Quality of Life (P-FiQ) study. Pain and HRQoL were assessed via PRO instruments in US adult males with hemophilia A or B and a history of joint pain or bleeding. PRO instruments included EQ-5D-5L with visual analog scale, Brief Pain Inventory v2 Short Form, SF-36v2, and Hemophilia Activities List. Instrument domain and item responses were described. Responses were collected from 381 adult males with a median age of 34 years. Pain was observed across instruments and affected daily activities and quality of life. Respondents reported functional impairment that limited the kind of work and activities they participated in, with activities involving the lower extremities being most affected. A high prevalence of mental health disorders was identified across instruments. Pain and HRQoL were evaluated using multiple PRO instruments, which vary in timescales of assessment and levels of detail. More consistent clinical assessments and patient dialog regarding pain and aspects of HRQoL may help drive improved outcomes. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
42 CFR 493.1413 - Standard; Technical consultant responsibilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
... consultant responsibilities. The technical consultant is responsible for the technical and scientific... of performance of instrument maintenance and function checks; (v) Assessment of test performance...
42 CFR 493.1413 - Standard; Technical consultant responsibilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... consultant responsibilities. The technical consultant is responsible for the technical and scientific... of performance of instrument maintenance and function checks; (v) Assessment of test performance...
Characterization of the LANDSAT sensors' spatial responses
NASA Technical Reports Server (NTRS)
Markham, B. L.
1984-01-01
The characteristics of the thematic mapper (TM) and multispectral scanner (MSS) sensors on LANDSATs 4 and 5 affecting their spatial responses are described, and functions defining the response of the system to an arbitrary input spatial pattern are derived, i.e., transfer functions (TF) and line spread functions (LSF). These design LSF's and TF's were modified based on prelaunch component and system measurements to provide improved estimates. Prelaunch estimates of LSF/FT's are compared to in-orbit estimates. For the MSS instruments, only limited prelaunch scan direction square-wave response (SWR) data were available. Design estimates were modified by convolving in Gaussian blur till the derived LSF/TF's produced SWR's comparable to the measurements. The two MSS instruments were comparable at their temperatures of best focus; separate calculations were performed for bands 1 and 3, band 2 and band 4. The pre-sample nadir effective instantaneous field's of view (EIFOV's) based on the .5 modulation transfer function (MTF) criteria vary from 70 to 75 meters in the track direction and 79 to 82 meters in the scan direction. For the TM instruments more extensive prelaunch measurements were available. Bands 1 to 4, 5 and 7, and 6 were handled separately as were the two instruments. Derived MTF's indicate nadir pre-sample EIFOV's of 32 to 33 meter track (bands 1 to 5, 7) and 36 meter scan (bands 1 to 5, 7) and 1245 meter track (band 6) and 141 meter scan (band 6) for both TM's.
Computer-Aided Instruction in Automated Instrumentation.
ERIC Educational Resources Information Center
Stephenson, David T.
1986-01-01
Discusses functions of automated instrumentation systems, i.e., systems which combine electrical measuring instruments and a controlling computer to measure responses of a unit under test. The computer-assisted tutorial then described is programmed for use on such a system--a modern microwave spectrum analyzer--to introduce engineering students to…
Vestibular Function Measurement Devices
Miles, Richard D.; Zapala, David A.
2015-01-01
Vestibular function laboratories utilize a multitude of diagnostic instruments to evaluate a dizzy patient. Caloric irrigators, oculomotor stimuli, and rotational chairs produce a stimulus whose accuracy is required for the patient response to be accurate. Careful attention to everything from cleanliness of equipment to threshold adjustments determine on a daily basis if patient data are going to be correct and useful. Instrumentation specifications that change with time such as speed and temperature must periodically be checked using calibrated instruments. PMID:27516710
Marfeo, Elizabeth E.; Ni, Pengsheng; Bogusz, Kara; Meterko, Mark; McDonough, Christine M.; Chan, Leighton; Rasch, Elizabeth K.; Brandt, Diane E.; Jette, Alan M.
2014-01-01
Objectives To use item response theory (IRT) data simulations to construct and perform initial psychometric testing of a newly developed instrument, the Social Security Administration Behavioral Health Function (SSA-BH) instrument, that aims to assess behavioral health functioning relevant to the context of work. Design Cross-sectional survey followed by item response theory (IRT) calibration data simulations Setting Community Participants A sample of individuals applying for SSA disability benefits, claimants (N=1015), and a normative comparative sample of US adults (N=1000) Interventions None. Main Outcome Measure Social Security Administration Behavioral Health Function (SSA-BH) measurement instrument Results Item response theory analyses supported the unidimensionality of four SSA-BH scales: Mood and Emotions (35 items), Self-Efficacy (23 items), Social Interactions (6 items), and Behavioral Control (15 items). All SSA-BH scales demonstrated strong psychometric properties including reliability, accuracy, and breadth of coverage. High correlations of the simulated 5- or 10- item CATs with the full item bank indicated robust ability of the CAT approach to comprehensively characterize behavioral health function along four distinct dimensions. Conclusions Initial testing and evaluation of the SSA-BH instrument demonstrated good accuracy, reliability, and content coverage along all four scales. Behavioral function profiles of SSA claimants were generated and compared to age and sex matched norms along four scales: Mood and Emotions, Behavioral Control, Social Interactions, and Self-Efficacy. Utilizing the CAT based approach offers the ability to collect standardized, comprehensive functional information about claimants in an efficient way, which may prove useful in the context of the SSA’s work disability programs. PMID:23542404
Angst, F; Aeschlimann, A; Steiner, W; Stucki, G
2001-01-01
OBJECTIVE—To compare the responsiveness of the condition-specific Western Ontario and McMaster Universities osteoarthritis (OA) index (WOMAC) and the generic Short Form-36 (SF-36) in patients with OA of the legs undergoing a comprehensive inpatient rehabilitation intervention. METHODS—A prospective follow up study of consecutively referred inpatients of a rehabilitation clinic was made. The patients included fulfilled the American College of Rheumatology criteria for knee or hip OA and underwent both passive and, particularly, active physical therapy for three to four weeks. Responsiveness assessment was performed using the standardised response mean (SRM), effect size, and Guyatt's responsiveness statistic between admission and discharge (end of rehabilitation) and then again between admission and three months later. For pain and function the SRMs were stratified by sex and OA joint. Effects were tested by the t test and SRMs of different scales were compared by the jack knife test. RESULTS—At the three month follow up, complete data were obtained for 223 patients. In general, the three responsiveness statistics showed a similar order of responsiveness. For both instruments, the pain scales were more responsive than the function scales. The responsiveness of the pain scale of both instruments was comparable (SRM=0.723 for WOMAC and SRM=0.528 for SF-36 at the end of rehabilitation; SRM=0.377 for WOMAC and SRM=0.468 for SF-36 at the three month follow up). In the measurement of function, the WOMAC was significantly more responsive than the SF-36 (SRMs, end of rehabilitation: 0.628 v 0.249; three month follow up: 0.235 v −0.001). Responsiveness tended to be higher in women and in knee OA than in men and hip OA. CONCLUSIONS—Both instruments, the WOMAC and the SF-36, capture improvement in pain in patients undergoing comprehensive inpatient rehabilitation intervention. Functional improvement can be detected better by the WOMAC than by the SF-36. All the other scales of both instruments were more weakly responsive. PMID:11502609
A preview of a modular surface light scattering instrument with autotracking optics
NASA Technical Reports Server (NTRS)
Meyer, William V.; Tin, Padetha; Mann, J. Adin, Jr.; Cheung, H. Michael; Rogers, Richard B.; Lading, Lars
1994-01-01
NASA's Advanced Technology Development (ATD) program is sponsoring the development of a new generation of surface light scattering hardware. This instrument is designed to non-invasively measure the surface response function of liquids over a wide range of operating conditions while automatically compensating for a sloshing surface. The surface response function can be used to compute surface tension, properties of monolayers present, viscosity, surface tension gradient and surface temperature. The instrument uses optical and electronic building blocks developed for the laser light scattering program at NASA Lewis along with several unique surface light scattering components. The emphasis of this paper is the compensation for bulk surface motion (slosh). Some data processing background information is also included.
Comparing the responsiveness of functional outcome assessment measures for trauma registries.
Williamson, Owen D; Gabbe, Belinda J; Sutherland, Ann M; Wolfe, Rory; Forbes, Andrew B; Cameron, Peter A
2011-07-01
Measuring long-term disability and functional outcomes after major trauma is not standardized across trauma registries. An ideal measure would be responsive to change but not have significant ceiling effects. The aim of this study was to compare the responsiveness of the Glasgow Outcome Scale (GOS), GOS-Extended (GOSE), Functional Independence Measure (FIM), and modified FIM in major trauma patients, with and without significant head injuries. Patients admitted to two adult Level I trauma centers in Victoria, Australia, who survived to discharge from hospital, were aged 15 years to 80 years with a blunt mechanism of injury, and had an estimated Injury Severity Score >15 on admission, were recruited for this prospective study. The instruments were administered at baseline (hospital discharge) and by telephone interview 6 months after injury. Measures of responsiveness, including effect sizes, were calculated. Bootstrapping techniques, and floor and ceiling effects, were used to compare the measures. Two hundred forty-three patients participated, of which 234 patients (96%) completed the study. The GOSE and GOS were the most responsive instruments in this major trauma population with effect sizes of 5.3 and 4.4, respectively. The GOSE had the lowest ceiling effect (17%). The GOSE was the instrument with greatest responsiveness and the lowest ceiling effect in a major trauma population with and without significant head injuries and is recommended for use by trauma registries for monitoring functional outcomes and benchmarking care. The results of this study do not support the use of the modified FIM for this purpose.
Uncertainty analysis of signal deconvolution using a measured instrument response function
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartouni, E. P.; Beeman, B.; Caggiano, J. A.
2016-10-05
A common analysis procedure minimizes the ln-likelihood that a set of experimental observables matches a parameterized model of the observation. The model includes a description of the underlying physical process as well as the instrument response function (IRF). Here, we investigate the National Ignition Facility (NIF) neutron time-of-flight (nTOF) spectrometers, the IRF is constructed from measurements and models. IRF measurements have a finite precision that can make significant contributions to the uncertainty estimate of the physical model’s parameters. Finally, we apply a Bayesian analysis to properly account for IRF uncertainties in calculating the ln-likelihood function used to find the optimummore » physical parameters.« less
Response function of modulated grid Faraday cup plasma instruments
NASA Technical Reports Server (NTRS)
Barnett, A.; Olbert, S.
1986-01-01
Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager plasma science experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. Multisensor analysis of solar wind data indicates that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.
Determining the neural substrates of goal-directed learning in the human brain.
Valentin, Vivian V; Dickinson, Anthony; O'Doherty, John P
2007-04-11
Instrumental conditioning is considered to involve at least two distinct learning systems: a goal-directed system that learns associations between responses and the incentive value of outcomes, and a habit system that learns associations between stimuli and responses without any link to the outcome that that response engendered. Lesion studies in rodents suggest that these two distinct components of instrumental conditioning may be mediated by anatomically distinct neural systems. The aim of the present study was to determine the neural substrates of the goal-directed component of instrumental learning in humans. Nineteen human subjects were scanned with functional magnetic resonance imaging while they learned to choose instrumental actions that were associated with the subsequent delivery of different food rewards (tomato juice, chocolate milk, and orange juice). After training, one of these foods was devalued by feeding the subject to satiety on that food. The subjects were then scanned again, while being re-exposed to the instrumental choice procedure (in extinction). We hypothesized that regions of the brain involved in goal-directed learning would show changes in their activity as a function of outcome devaluation. Our results indicate that neural activity in one brain region in particular, the orbitofrontal cortex, showed a strong modulation in its activity during selection of a devalued compared with a nondevalued action. These results suggest an important contribution of orbitofrontal cortex in guiding goal-directed instrumental choices in humans.
Amplitude Frequency Response Measurement: A Simple Technique
ERIC Educational Resources Information Center
Satish, L.; Vora, S. C.
2010-01-01
A simple method is described to combine a modern function generator and a digital oscilloscope to configure a setup that can directly measure the amplitude frequency response of a system. This is achieved by synchronously triggering both instruments, with the function generator operated in the "Linear-Sweep" frequency mode, while the oscilloscope…
NASA Astrophysics Data System (ADS)
Pagonis, D.; Deming, B.; Krechmer, J. E.; De Gouw, J. A.; Jimenez, J. L.; Ziemann, P. J.
2017-12-01
Recently it has been shown that gas-phase organic compounds partition to and from the walls of Teflon environmental chambers. This process is fast, reversible, and can be modeled as absorptive partitioning. Here these studies were extended to investigate gas-wall partitioning inside Teflon tubing by introducing step function changes in the concentration of compounds being sampled and measuring the delay in the response of a proton transfer reaction-mass spectrometer (PTR-MS). We find that these delays are significant for compounds with a saturation vapor concentration (c*) below 106 μg m-3, and that the Teflon tubing and the PTR-MS both contribute to the delays. Tubing delays range from minutes to hours under common sampling conditions and can be accurately predicted by a simple chromatography model across a range of tubing lengths and diameters, flow rates, compound functional groups, and c*. This method also allows one to determine the volatility-dependent response function of an instrument, which can be convolved with the output of the tubing model to correct for delays in instrument response time for these "sticky" compounds. This correction is expected to be of particular interest to researchers utilizing and developing chemical ionization mass spectrometry (CIMS) techniques, since many of the multifunctional organic compounds detected by CIMS show significant tubing and instrument delays. These results also enable better design of sampling systems, in particular when fast instrument response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. Additional results presented here extend this method to quantify the relative sorptive capacities for other commonly used tubing materials, including PFA, FEP, PTFE, PEEK, glass, copper, stainless steel, and passivated steel.
Ni, Pengsheng; McDonough, Christine M; Jette, Alan M; Bogusz, Kara; Marfeo, Elizabeth E; Rasch, Elizabeth K; Brandt, Diane E; Meterko, Mark; Haley, Stephen M; Chan, Leighton
2013-09-01
To develop and test an instrument to assess physical function for Social Security Administration (SSA) disability programs, the SSA-Physical Function (SSA-PF) instrument. Item response theory (IRT) analyses were used to (1) create a calibrated item bank for each of the factors identified in prior factor analyses, (2) assess the fit of the items within each scale, (3) develop separate computer-adaptive testing (CAT) instruments for each scale, and (4) conduct initial psychometric testing. Cross-sectional data collection; IRT analyses; CAT simulation. Telephone and Internet survey. Two samples: SSA claimants (n=1017) and adults from the U.S. general population (n=999). None. Model fit statistics, correlation, and reliability coefficients. IRT analyses resulted in 5 unidimensional SSA-PF scales: Changing & Maintaining Body Position, Whole Body Mobility, Upper Body Function, Upper Extremity Fine Motor, and Wheelchair Mobility for a total of 102 items. High CAT accuracy was demonstrated by strong correlations between simulated CAT scores and those from the full item banks. On comparing the simulated CATs with the full item banks, very little loss of reliability or precision was noted, except at the lower and upper ranges of each scale. No difference in response patterns by age or sex was noted. The distributions of claimant scores were shifted to the lower end of each scale compared with those of a sample of U.S. adults. The SSA-PF instrument contributes important new methodology for measuring the physical function of adults applying to the SSA disability programs. Initial evaluation revealed that the SSA-PF instrument achieved considerable breadth of coverage in each content domain and demonstrated noteworthy psychometric properties. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Horvath, P.
1979-01-01
Inverse filters were designed to correct the effect of instrumental response, coupling of the seismometer to the ground, and near surface structures. The least squares technique was used to determine the instrumental constants and the transfer functions of the long period lunar seismographs. The influence of noise and the results of these calculations are discussed.
NASA Technical Reports Server (NTRS)
Ackermann, M.; Ajello, M.; Albert, A.; Allafort, A.; Atwood, W. B.; Axelsson, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.;
2012-01-01
The Fermi Large Area Telescope (Fermi-LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy -ray telescope, covering the energy range from 20 MeV to more than 300 GeV. During the first years of the mission the LAT team has gained considerable insight into the in-flight performance of the instrument. Accordingly, we have updated the analysis used to reduce LAT data for public release as well as the Instrument Response Functions (IRFs), the description of the instrument performance provided for data analysis. In this paper we describe the effects that motivated these updates. Furthermore, we discuss how we originally derived IRFs from Monte Carlo simulations and later corrected those IRFs for discrepancies observed between flight and simulated data. We also give details of the validations performed using flight data and quantify the residual uncertainties in the IRFs. Finally, we describe techniques the LAT team has developed to propagate those uncertainties into estimates of the systematic errors on common measurements such as fluxes and spectra of astrophysical sources.
NASA Astrophysics Data System (ADS)
Plemmons, Dayne A.; Flannigan, David J.
2017-09-01
We determine the instrument response of an ultrafast electron microscope equipped with a conventional thermionic electron gun and absent modifications beyond the optical ports. Using flat, graphite-encircled LaB6 cathodes, we image space-charge effects as a function of photoelectron-packet population and find that an applied Wehnelt bias has a negligible effect on the threshold levels (>103 electrons per pulse) but does appear to suppress blurring at the upper limits (∼105 electrons). Using plasma lensing, we determine the instrument-response time for 700-fs laser pulses and find that single-electron packets are laser limited (1 ps), while broadening occurs well below the space-charge limit.
ERIC Educational Resources Information Center
Tiffin, Paul A.; Kaplan, Carole; Place, Maurice
2011-01-01
A pool of 75 items relating to family functioning was created and piloted in a sample of 12-18 year olds (N = 673). The responses were subjected to an exploratory factor analysis which indicated the presence of three significant latent traits. The results were then used to inform the development of a rating instrument with five subscales labelled…
Physiologic measures of sexual function in women: a review.
Woodard, Terri L; Diamond, Michael P
2009-07-01
To review and describe physiologic measures of assessing sexual function in women. Literature review. Studies that use instruments designed to measure female sexual function. Women participating in studies of female sexual function. Various instruments that measure physiologic features of female sexual function. Appraisal of the various instruments, including their advantages and disadvantages. Many unique physiologic methods of evaluating female sexual function have been developed during the past four decades. Each method has its benefits and limitations. Many physiologic methods exist, but most are not well-validated. In addition there has been an inability to correlate most physiologic measures with subjective measures of sexual arousal. Furthermore, given the complex nature of the sexual response in women, physiologic measures should be considered in context of other data, including the history, physical examination, and validated questionnaires. Nonetheless, the existence of appropriate physiologic measures is vital to our understanding of female sexual function and dysfunction.
NASA Astrophysics Data System (ADS)
Herman, Jay R.
2010-12-01
Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone Ω, U(Ω/200)-RAF, where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 nm) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.
NASA Technical Reports Server (NTRS)
Herman, Jay R.
2010-01-01
Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone OMEGA, U(OMEGA/200)(sup -RAF), where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 run) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.
Tokuda, Yasuharu; Okubo, Tomoya; Ohde, Sachiko; Jacobs, Joshua; Takahashi, Osamu; Omata, Fumio; Yanai, Haruo; Hinohara, Shigeaki; Fukui, Tsuguya
2009-06-01
The Short Form-8 (SF-8) questionnaire is a commonly used 8-item instrument of health-related quality of life (QOL) and provides a health profile of eight subdimensions. Our aim was to examine the psychometric properties of the Japanese version of the SF-8 instrument using methodology based on nominal categories model. Using data from an adjusted random sample from a nationally representative panel, the nominal categories modeling was applied to SF-8 items to characterize coverage of the latent trait (theta). Probabilities for response choices were described as functions on the latent trait. Information functions were generated based on the estimated item parameters. A total of 3344 participants (53%, women; median age, 35 years) provided responses. One factor was retained (eigenvalue, 4.65; variance proportion of 0.58) and used as theta. All item response category characteristic curves satisfied the monotonicity assumption in accurate order with corresponding ordinal responses. Four items (general health, bodily pain, vitality, and mental health) cover most of the spectrum of theta, while the other four items (physical function, role physical [role limitations because of physical health], social functioning, and role emotional [role limitations because of emotional problems] ) cover most of the negative range of theta. Information function for all items combined peaked at -0.7 of theta (information = 18.5) and decreased with increasing theta. The SF-8 instrument performs well among those with poor QOL across the continuum of the latent trait and thus can recognize more effectively persons with relatively poorer QOL than those with relatively better QOL.
Abma, Femke I; van der Klink, Jac J L; Terwee, Caroline B; Amick, Benjamin C; Bültmann, Ute
2012-01-01
During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in occupational health practice and research, the measurement properties (eg, reliability, validity, responsiveness) must be evaluated. The objective of this study is to appraise critically and compare the measurement properties of self-reported health-related work-functioning instruments among workers with CMD. A systematic review was performed searching three electronic databases. Papers were included that: (i) mainly focused on the development and/or evaluation of the measurement properties of a self-reported health-related work-functioning instrument; (ii) were conducted in a CMD population; and (iii) were fulltext original papers. Quality appraisal was performed using the consensus-based standards for the selection of health status measurement instruments (COSMIN) checklist. Five papers evaluating measurement properties of five self-reported health-related work-functioning instruments in CMD populations were included. There is little evidence available for the measurement properties of the identified instruments in this population, mainly due to low methodological quality of the included studies. The available evidence on measurement properties is based on studies of poor-to-fair methodological quality. Information on a number of measurement properties, such as measurement error, content validity, and cross-cultural validity is still lacking. Therefore, no evidence-based decisions and recommendations can be made for the use of health-related work functioning instruments. Studies of high methodological quality are needed to properly assess the existing instruments' measurement properties.
An investigation of soil-structure interaction effects observed at the MIT Green Building
Taciroglu, Ertugrul; Çelebi, Mehmet; Ghahari, S. Farid; Abazarsa, Fariba
2016-01-01
The soil-foundation impedance function of the MIT Green Building is identified from its response signals recorded during an earthquake. Estimation of foundation impedance functions from seismic response signals is a challenging task, because: (1) the foundation input motions (FIMs) are not directly measurable, (2) the as-built properties of the super-structure are only approximately known, and (3) the soil-foundation impedance functions are inherently frequency-dependent. In the present study, aforementioned difficulties are circumvented by using, in succession, a blind modal identification (BMID) method, a simplified Timoshenko beam model (TBM), and a parametric updating of transfer functions (TFs). First, the flexible-base modal properties of the building are identified from response signals using the BMID method. Then, a flexible-base TBM is updated using the identified modal data. Finally, the frequency-dependent soil-foundation impedance function is estimated by minimizing the discrepancy between TFs (of pairs instrumented floors) that are (1) obtained experimentally from earthquake data and (2) analytically from the updated TBM. Using the fully identified flexible-base TBM, the FIMs as well as building responses at locations without instruments can be predicted, as demonstrated in the present study.
Adaptation of the Practice Environment Scale for military nurses: a psychometric analysis.
Swiger, Pauline A; Raju, Dheeraj; Breckenridge-Sproat, Sara; Patrician, Patricia A
2017-09-01
The aim of this study was to confirm the psychometric properties of Practice Environment Scale of the Nursing Work Index in a military population. This study also demonstrates association rule analysis, a contemporary exploratory technique. One of the instruments most commonly used to evaluate the nursing practice environment is the Practice Environment Scale of the Nursing Work Index. Although the instrument has been widely used, the reliability, validity and individual item function are not commonly evaluated. Gaps exist with regard to confirmatory evaluation of the subscale factors, individual item analysis and evaluation in the outpatient setting and with non-registered nursing staff. This was a secondary data analysis of existing survey data. Multiple psychometric methods were used for this analysis using survey data collected in 2014. First, descriptive analyses were conducted, including exploration using association rules. Next, internal consistency was tested and confirmatory factor analysis was performed to test the factor structure. The specified factor structure did not hold; therefore, exploratory factor analysis was performed. Finally, item analysis was executed using item response theory. The differential item functioning technique allowed the comparison of responses by care setting and nurse type. The results of this study indicate that responses differ between groups and that several individual items could be removed without altering the psychometric properties of the instrument. The instrument functions moderately well in a military population; however, researchers may want to consider nurse type and care setting during analysis to identify any meaningful variation in responses. © 2017 John Wiley & Sons Ltd.
[Construct validity of a Portuguese version of the Female Sexual Function Index].
Pacagnella, Rodolfo de Carvalho; Martinez, Edson Zangiacomi; Vieira, Elisabeth Meloni
2009-11-01
This study aimed to evaluate the construct validity of a version of the Female Sexual Function Index (FSFI). The version was inserted into a multidimensional questionnaire and applied face-to-face to 235 sterilized women. Non-response rate was 1.7%. The sample proved to be highly homogeneous, with low income and education. Cronbach's alpha of 0.948 indicated high internal consistency. Factor analysis showed that the instrument was measuring four factors: desire/arousal, lubrication, orgasm/satisfaction, and pain. This may reflect characteristics of the instrument itself, female sexual response, or even the sample's cultural peculiarities, which can affect understanding of the questions or concepts with which the instrument deals. This study emphasizes the need for further research in the general population to determine the psychometric properties of the FSFI, such as its factor composition and definition of appropriate cut-off points for the Brazilian population.
The response function of modulated grid Faraday cup plasma instruments
NASA Technical Reports Server (NTRS)
Barnett, A.; Olbert, S.
1986-01-01
Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager Plasma Science (PLS) experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. The theoretical formulas were tested by multi-sensor analysis of solar wind data. The tests indicate that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.
Ackermann, M.; Ajello, M.; Albert, A.; ...
2012-10-12
The Fermi Large Area Telescope (Fermi-LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy γ-ray telescope, covering the energy range from 20 MeV to more than 300 GeV. During the first years of the mission, the LAT team has gained considerable insight into the in-flight performance of the instrument. Accordingly, we have updated the analysis used to reduce LAT data for public release as well as the instrument response functions (IRFs), the description of the instrument performance provided for data analysis. In this study, we describe the effects thatmore » motivated these updates. Furthermore, we discuss how we originally derived IRFs from Monte Carlo simulations and later corrected those IRFs for discrepancies observed between flight and simulated data. We also give details of the validations performed using flight data and quantify the residual uncertainties in the IRFs. In conclusion, we describe techniques the LAT team has developed to propagate those uncertainties into estimates of the systematic errors on common measurements such as fluxes and spectra of astrophysical sources.« less
Enke, Christie
2013-02-19
Methods and instruments for high dynamic range analysis of sample components are described. A sample is subjected to time-dependent separation, ionized, and the ions dispersed with a constant integration time across an array of detectors according to the ions m/z values. Each of the detectors in the array has a dynamically adjustable gain or a logarithmic response function, producing an instrument capable of detecting a ratio of responses or 4 or more orders of magnitude.
Performance of the PROMIS in Patients After Anterior Cruciate Ligament Reconstruction
Scott, Elizabeth J.; Westermann, Robert; Glass, Nathalie A.; Hettrich, Carolyn; Wolf, Brian R.; Bollier, Matthew J.
2018-01-01
Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) is designed to advance patient-reported outcome (PRO) instruments by utilizing question banks for major health domains. Purpose: To compare the responsiveness and construct validity of the PROMIS physical function computer adaptive test (PF CAT) with current PRO instruments for patients before and up to 2 years after anterior cruciate ligament (ACL) reconstruction. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Initially, 157 patients completed the PROMIS PF CAT, Short Form–36 Health Survey (SF-36 physical function [PF] and general health [GH]), Marx Activity Rating Scale (MARS), Knee injury and Osteoarthritis Outcome Score (KOOS activities of daily living [ADL], sport, and quality of life [QOL]), and EuroQol–5 dimensions questionnaire (EQ-5D) at 6 weeks, 6 months, and 2 years after ACL reconstruction. Correlations between instruments, ceiling and floor effects, effect sizes (Cohen d), and standardized response means to describe responsiveness were evaluated. Subgroup analyses compared participants with and without additional arthroscopic procedures using linear mixed models. Results: At baseline, 6 weeks, and 6 months, the PROMIS PF CAT showed excellent or excellent-good correlations with the SF-36 PF (r = 0.75-0.80, P < .01), KOOS-ADL (r = 0.63-0.70, P < .01), and KOOS-sport (r = 0.32-0.69, P < .01); excellent-good correlation with the EQ-5D (r = 0.60-0.71, P < .01); and good correlation with the KOOS-QOL (r = 0.52-0.58, P < .01). As expected, there were poor correlations with the MARS (r = 0.00-0.24, P < .01) and SF-36 GH (r = 0.16-0.34, P < .01 ). At 2 years, the PROMIS PF CAT showed good to excellent correlations with all PRO instruments (r = 0.42-0.72, P < .01), including the MARS (r = 0.42, P < .01), indicating frequent return to preinjury function. The PROMIS PF CAT had the fewest ceiling or floor effects of all instruments tested, and patients answered, on average, 4 questions. There was no significant difference in baseline physical function scores between subgroups; at follow-up, all groups showed improvements in scores that were not statistically different. Conclusion: The PROMIS PF CAT is a valid tool to assess outcomes after ACL reconstruction up to 2 years after surgery, demonstrating the highest responsiveness to change with the fewest ceiling and floor effects and a low time burden among all instruments tested. The PROMIS PF CAT is a beneficial alternative for assessing physical function in adults before and after ACL reconstruction. PMID:29854864
Performance of the PROMIS in Patients After Anterior Cruciate Ligament Reconstruction.
Scott, Elizabeth J; Westermann, Robert; Glass, Nathalie A; Hettrich, Carolyn; Wolf, Brian R; Bollier, Matthew J
2018-05-01
The Patient-Reported Outcomes Measurement Information System (PROMIS) is designed to advance patient-reported outcome (PRO) instruments by utilizing question banks for major health domains. To compare the responsiveness and construct validity of the PROMIS physical function computer adaptive test (PF CAT) with current PRO instruments for patients before and up to 2 years after anterior cruciate ligament (ACL) reconstruction. Cohort study (diagnosis); Level of evidence, 2. Initially, 157 patients completed the PROMIS PF CAT, Short Form-36 Health Survey (SF-36 physical function [PF] and general health [GH]), Marx Activity Rating Scale (MARS), Knee injury and Osteoarthritis Outcome Score (KOOS activities of daily living [ADL], sport, and quality of life [QOL]), and EuroQol-5 dimensions questionnaire (EQ-5D) at 6 weeks, 6 months, and 2 years after ACL reconstruction. Correlations between instruments, ceiling and floor effects, effect sizes (Cohen d ), and standardized response means to describe responsiveness were evaluated. Subgroup analyses compared participants with and without additional arthroscopic procedures using linear mixed models. At baseline, 6 weeks, and 6 months, the PROMIS PF CAT showed excellent or excellent-good correlations with the SF-36 PF ( r = 0.75-0.80, P < .01), KOOS-ADL ( r = 0.63-0.70, P < .01), and KOOS-sport ( r = 0.32-0.69, P < .01); excellent-good correlation with the EQ-5D ( r = 0.60-0.71, P < .01); and good correlation with the KOOS-QOL ( r = 0.52-0.58, P < .01). As expected, there were poor correlations with the MARS ( r = 0.00-0.24, P < .01) and SF-36 GH ( r = 0.16-0.34, P < .01 ). At 2 years, the PROMIS PF CAT showed good to excellent correlations with all PRO instruments ( r = 0.42-0.72, P < .01), including the MARS ( r = 0.42, P < .01), indicating frequent return to preinjury function. The PROMIS PF CAT had the fewest ceiling or floor effects of all instruments tested, and patients answered, on average, 4 questions. There was no significant difference in baseline physical function scores between subgroups; at follow-up, all groups showed improvements in scores that were not statistically different. The PROMIS PF CAT is a valid tool to assess outcomes after ACL reconstruction up to 2 years after surgery, demonstrating the highest responsiveness to change with the fewest ceiling and floor effects and a low time burden among all instruments tested. The PROMIS PF CAT is a beneficial alternative for assessing physical function in adults before and after ACL reconstruction.
Inflammatory Cytokines as Preclinical Markers of Adverse Responses to Chemical Stressors
Abstract: The in vivo cytokine response to chemical stressors is a promising mainstream tool used to assess potential systemic inflammation and immune function changes. Notably, new instrumentation and statistical analysis provide the selectivity and sensitivity to rapidly diff...
Dealing with non-unique and non-monotonic response in particle sizing instruments
NASA Astrophysics Data System (ADS)
Rosenberg, Phil
2017-04-01
A number of instruments used as de-facto standards for measuring particle size distributions are actually incapable of uniquely determining the size of an individual particle. This is due to non-unique or non-monotonic response functions. Optical particle counters have non monotonic response due to oscillations in the Mie response curves, especially for large aerosol and small cloud droplets. Scanning mobility particle sizers respond identically to two particles where the ratio of particle size to particle charge is approximately the same. Images of two differently sized cloud or precipitation particles taken by an optical array probe can have similar dimensions or shadowed area depending upon where they are in the imaging plane. A number of methods exist to deal with these issues, including assuming that positive and negative errors cancel, smoothing response curves, integrating regions in measurement space before conversion to size space and matrix inversion. Matrix inversion (also called kernel inversion) has the advantage that it determines the size distribution which best matches the observations, given specific information about the instrument (a matrix which specifies the probability that a particle of a given size will be measured in a given instrument size bin). In this way it maximises use of the information in the measurements. However this technique can be confused by poor counting statistics which can cause erroneous results and negative concentrations. Also an effective method for propagating uncertainties is yet to be published or routinely implemented. Her we present a new alternative which overcomes these issues. We use Bayesian methods to determine the probability that a given size distribution is correct given a set of instrument data and then we use Markov Chain Monte Carlo methods to sample this many dimensional probability distribution function to determine the expectation and (co)variances - hence providing a best guess and an uncertainty for the size distribution which includes contributions from the non-unique response curve, counting statistics and can propagate calibration uncertainties.
Improved effectiveness of performance monitoring in amateur instrumental musicians☆
Jentzsch, Ines; Mkrtchian, Anahit; Kansal, Nayantara
2014-01-01
Here we report a cross-sectional study investigating the influence of instrumental music practice on the ability to monitor for and respond to processing conflicts and performance errors. Behavioural and electrophysiological indicators of response monitoring in amateur musicians with various skill levels were collected using simple conflict tasks. The results show that instrumental musicians are better able than non-musicians to detect conflicts and errors as indicated by systematic increases in the amplitude of the error-related negativity and the N200 with increasing levels of instrumental practice. Also, high levels of musical training were associated with more efficient and less reactive responses after experience of conflicts and errors as indicated by reduced post-error interference and post-conflict processing adjustments. Together, the present findings suggest that playing a musical instrument might improve the ability to monitor our behavior and adjust our responses effectively when needed. As these processes are amongst the first to be affected by cognitive aging, our evidence could promote musical activity as a realistic intervention to slow or even prevent age-related decline in frontal cortex mediated executive functioning. PMID:24056298
Validation study of a web-based assessment of functional recovery after radical prostatectomy.
Vickers, Andrew J; Savage, Caroline J; Shouery, Marwan; Eastham, James A; Scardino, Peter T; Basch, Ethan M
2010-08-05
Good clinical care of prostate cancer patients after radical prostatectomy depends on careful assessment of post-operative morbidities, yet physicians do not always judge patient symptoms accurately. Logistical problems associated with using paper questionnaire limit their use in the clinic. We have implemented a web-interface ("STAR") for patient-reported outcomes after radical prostatectomy. We analyzed data on the first 9 months of clinical implementation to evaluate the validity of the STAR questionnaire to assess functional outcomes following radical prostatectomy. We assessed response rate, internal consistency within domains, and the association between survey responses and known predictors of sexual and urinary function, including age, time from surgery, nerve sparing status and co-morbidities. Of 1581 men sent an invitation to complete the instrument online, 1235 responded for a response rate of 78%. Cronbach's alpha was 0.84, 0.86 and 0.97 for bowel, urinary and sexual function respectively. All known predictors of sexual and urinary function were significantly associated with survey responses in the hypothesized direction. We have found that web-based assessment of functional recovery after radical prostatectomy is practical and feasible. The instrument demonstrated excellent psychometric properties, suggested that validity is maintained when questions are transferred from paper to electronic format and when patients give responses that they know will be seen by their doctor and added to their clinic record. As such, our system allows ready implementation of patient-reported outcomes into routine clinical practice.
Validation study of a web-based assessment of functional recovery after radical prostatectomy
2010-01-01
Background Good clinical care of prostate cancer patients after radical prostatectomy depends on careful assessment of post-operative morbidities, yet physicians do not always judge patient symptoms accurately. Logistical problems associated with using paper questionnaire limit their use in the clinic. We have implemented a web-interface ("STAR") for patient-reported outcomes after radical prostatectomy. Methods We analyzed data on the first 9 months of clinical implementation to evaluate the validity of the STAR questionnaire to assess functional outcomes following radical prostatectomy. We assessed response rate, internal consistency within domains, and the association between survey responses and known predictors of sexual and urinary function, including age, time from surgery, nerve sparing status and co-morbidities. Results Of 1581 men sent an invitation to complete the instrument online, 1235 responded for a response rate of 78%. Cronbach's alpha was 0.84, 0.86 and 0.97 for bowel, urinary and sexual function respectively. All known predictors of sexual and urinary function were significantly associated with survey responses in the hypothesized direction. Conclusions We have found that web-based assessment of functional recovery after radical prostatectomy is practical and feasible. The instrument demonstrated excellent psychometric properties, suggested that validity is maintained when questions are transferred from paper to electronic format and when patients give responses that they know will be seen by their doctor and added to their clinic record. As such, our system allows ready implementation of patient-reported outcomes into routine clinical practice. PMID:20687938
Lee, Augustine C; Driban, Jeffrey B; Price, Lori Lyn; Harvey, William F; Rodday, Angie Mae; Wang, Chenchen
2017-09-01
Patient-Reported Outcomes Measurement Information System (PROMIS) instruments can provide valid, interpretable measures of health status among adults with osteoarthritis (OA). However, their ability to detect meaningful change over time is unknown. We evaluated the responsiveness and minimally important differences (MIDs) for 4 PROMIS Short Forms: Physical Function, Pain Interference, Depression, and Anxiety. We analyzed adults with symptomatic knee OA from our randomized trial comparing Tai Chi and physical therapy. Using baseline and 12-week scores, responsiveness was evaluated according to consensus standards by testing 6 a priori hypotheses of the correlations between PROMIS and legacy change scores. Responsiveness was considered high if ≥5 hypotheses were confirmed, and moderate if 3 or 4 were confirmed. MIDs were evaluated according to prospective change for people achieving previously-established MID on legacy comparators. The lowest and highest MIDs meeting a priori quality criteria formed a MID range for each PROMIS Short Form. Among 165 predominantly female (70%) and white (57%) participants, mean age was 61 years and body mass index was 33. PROMIS Physical Function had 5 confirmed hypotheses and Pain Interference, Depression, and Anxiety had 3 or 4. MID ranges were: Depression = 3.0 to 3.1; Anxiety = 2.3 to 3.4; Physical Function = 1.9 to 2.2; and Pain Interference = 2.35 to 2.4. PROMIS Physical Function has high responsiveness, and Depression, Anxiety, and Pain Interference have moderate responsiveness among adults with knee OA. We established the first MIDs for PROMIS in this population, and provided an important standard of reference to better apply or interpret PROMIS in future trials or clinical practice. This study examined whether PROMIS Short Form instruments (Physical Function, Pain Interference, Depression, and Anxiety) were able to detect change over time among adults with knee OA, and provided minimally important change estimates for each measure. This standard of reference can help apply or interpret these instruments in the future. Copyright © 2017. Published by Elsevier Inc.
Music therapy assessment for severely emotionally disturbed children: a pilot study.
Layman, Deborah L; Hussey, David L; Laing, Sarah J
2002-01-01
The purpose of this study was to pilot a music therapy assessment instrument for severely emotionally disturbed children. The subjects in this pilot were 20 children, 13 male and 7 female, at a residential treatment center in Cleveland, Ohio. After conducting an extensive literature review, the authors developed a music therapy assessment instrument measuring 4 relevant domains: behavioral/social functioning, emotional responsiveness, language/communication abilities, and music skills. Responses were coded into 3 categories: defensive/withdrawn, target behavior, and disruptive/intrusive. Results demonstrated that subjects displayed significantly more behaviors in the disruptive/intrusive domain. High inter-rater reliability scores of 91.5% for percent agreement and .808 for Cohen's kappa were achieved utilizing this assessment instrument.
NASA Technical Reports Server (NTRS)
Daniels, Janet L.; Smith, G. Louis; Priestley, Kory J.; Thomas, Susan
2014-01-01
Validation of in-orbit instrument performance is a function of stability in both instrument and calibration source. This paper describes a method using lunar observations scanning near full moon by the Clouds and Earth Radiant Energy System (CERES) instruments. The Moon offers an external source whose signal variance is predictable and non-degrading. From 2006 to present, these in-orbit observations have become standardized and compiled for the Flight Models -1 and -2 aboard the Terra satellite, for Flight Models-3 and -4 aboard the Aqua satellite, and beginning 2012, for Flight Model-5 aboard Suomi-NPP. Instrument performance measurements studied are detector sensitivity stability, pointing accuracy and static detector point response function. This validation method also shows trends per CERES data channel of 0.8% per decade or less for Flight Models 1-4. Using instrument gimbal data and computed lunar position, the pointing error of each detector telescope, the accuracy and consistency of the alignment between the detectors can be determined. The maximum pointing error was 0.2 Deg. in azimuth and 0.17 Deg. in elevation which corresponds to an error in geolocation near nadir of 2.09 km. With the exception of one detector, all instruments were found to have consistent detector alignment from 2006 to present. All alignment error was within 0.1o with most detector telescopes showing a consistent alignment offset of less than 0.02 Deg.
ERIC Educational Resources Information Center
Fahlgren, Maria
2017-01-01
This paper examines the process of instrumental genesis through which students develop their proficiency in making use of movable points and slider bars--two tools that dynamic mathematics software provides for working with variable coordinates and parameters in the field of functions. The paper analyses students' responses to task sequences…
Instrumentation Guidelines for the Advanced National Seismic System
Working Group on Instrumentation, Siting
2008-01-01
This document provides guidelines for the seismic-monitoring instrumentation used by long-term earthquake-monitoring stations that will sense ground motion, digitize and store the resulting signals in a local data acquisition unit, and optionally transmit these digital data. These guidelines are derived from specifications and requirements for data needed to address the nation's emergency response, engineering, and scientific needs as identified in U.S. Geological Survey Circular 1188 (1999). Data needs are discussed in terms of national, regional, and urban scales of monitoring in section 3. Functional performance specifications for instrumentation are introduced in section 4.3 and discussed in detail in section 6 in terms of instrument classes and definitions described in section 5. System aspects and testing recommendations are discussed in sections 7 and 8, respectively. Although U.S. Geological Survey Circular 1188 (1999) recommends that the Advanced National Seismic System (ANSS) include portable instrumentation, performance specifications for this element are not specifically addressed in this document. Nevertheless, these guidelines are largely applicable to portable instrumentation. Volcano monitoring instrumentation is also beyond the scope of this document. Guidance for ANSS structural-response monitoring is discussed briefly herein but details are deferred to the ANSS document by the ANSS Structural Response Monitoring Committee (U.S. Geological Survey, 2005). Aspects of station planning, siting, and installation other than instrumentation are beyond the scope of this document.
NASA Astrophysics Data System (ADS)
Puszka, Agathe; Planat-Chrétien, Anne; Berger, Michel; Hervé, Lionel; Dinten, Jean-Marc
2014-02-01
We demonstrate the loss of depth sensitivity induced by the instrument response function on reflectance time-resolved diffuse optical tomography through the comparison of 3 detection systems: on one hand a photomultiplier tube (PMT) and a hybrid PMT coupled with a time-correlated single-photon counting card and on the other hand a high rate intensified camera. We experimentally evaluate the depth sensitivity achieved for each detection module with an absorbing inclusion embedded in a turbid medium. The different interfiber distances of 5, 10 and 15 mm are considered. Finally, we determine a maximal depth reached for each detection system by using 3D tomographic reconstructions based on the Mellin-Laplace transform.
Ni, Pengsheng; McDonough, Christine M.; Jette, Alan M.; Bogusz, Kara; Marfeo, Elizabeth E.; Rasch, Elizabeth K.; Brandt, Diane E.; Meterko, Mark; Chan, Leighton
2014-01-01
Objectives To develop and test an instrument to assess physical function (PF) for Social Security Administration (SSA) disability programs, the SSA-PF. Item Response Theory (IRT) analyses were used to 1) create a calibrated item bank for each of the factors identified in prior factor analyses, 2) assess the fit of the items within each scale, 3) develop separate Computer-Adaptive Test (CAT) instruments for each scale, and 4) conduct initial psychometric testing. Design Cross-sectional data collection; IRT analyses; CAT simulation. Setting Telephone and internet survey. Participants Two samples: 1,017 SSA claimants, and 999 adults from the US general population. Interventions None. Main Outcome Measure Model fit statistics, correlation and reliability coefficients, Results IRT analyses resulted in five unidimensional SSA-PF scales: Changing & Maintaining Body Position, Whole Body Mobility, Upper Body Function, Upper Extremity Fine Motor, and Wheelchair Mobility for a total of 102 items. High CAT accuracy was demonstrated by strong correlations between simulated CAT scores and those from the full item banks. Comparing the simulated CATs to the full item banks, very little loss of reliability or precision was noted, except at the lower and upper ranges of each scale. No difference in response patterns by age or sex was noted. The distributions of claimant scores were shifted to the lower end of each scale compared to those of a sample of US adults. Conclusions The SSA-PF instrument contributes important new methodology for measuring the physical function of adults applying to the SSA disability programs. Initial evaluation revealed that the SSA-PF instrument achieved considerable breadth of coverage in each content domain and demonstrated noteworthy psychometric properties. PMID:23578594
An Externally Dispersed Interferometer for Sensitive Doppler Extrasolar Planet Searches
NASA Astrophysics Data System (ADS)
Ge, Jian; Erskine, David J.; Rushford, Mike
2002-09-01
A new kind of instrument for sensitive Doppler extrasolar planet searches, called an externally dispersed interferometer, is described in this paper. It is a combination of an optical Michelson-type interferometer and an intermediate-resolution grating spectrometer. The interferometer measures Doppler radial velocity (RV) variations of starlight through the phase shifts of moiré fringes, created by multiplication of the interferometer fringes with stellar absorption lines. The intermediate-resolution spectrograph disperses the moiré fringes into thousands of parallel-wavelength channels. This increases the instrument bandwidth and fringe visibility by preventing fringe cross-talk between neighboring spectral lines. This results in a net increase in the signal-to-noise ratio over an interferometer used alone with broadband light. Compared to current echelle spectrometers for extrasolar planet searches, this instrument offers two unique instrument properties: a simple, stable, well-defined sinusoidal instrument response function (point-spread function) and magnification of Doppler motion through moiré fringe techniques. Since instrument noise is chiefly limited by the ability to characterize the instrument response, this new technique provides unprecedented low instrumental noise in an economical compact apparatus, enabling higher precision for Doppler RV measurements. In practice, the moiré magnification can be 5-10 times depending on the interferometer comb angle. This instrument has better sensitivity for smaller Doppler shifts than echelle spectrometers. The instrument can be designed with much lower spectral resolving power without losing Doppler sensitivity and optimized for higher throughput than echelle spectrometers to allow a potential survey for planets around fainter stars than current magnitude limits. Lab-based experiments with a prototype instrument with a spectral resolution of R~20,000 demonstrated ~0.7 m s-1 precision for short-term RV measurements. A fiber-fed version of the prototype with R~5600 was tested with starlight at the Lick 1 m telescope and demonstrated ~7 m s-1 RV precision at 340 Å bandwidth. The increased velocity noise is attributed to the lower spectral resolution, lower fringe visibility, and uncontrolled instrument environment.
NASA Technical Reports Server (NTRS)
Greene, E. P.
1976-01-01
The requirements for mission-operations data management will accelerate sharply when the Space Transportation System (i.e., Space Shuttle) becomes the primary vehicle for research from space. These demands can be satisfied most effectively by providing a higher-level source encoding function within the spaceborne vehicle. An Instrument Telemetry Packet (ITP) concept is described which represents an alternative to the conventional multiplexed telemetry frame approach for acquiring spaceborne instrument data. By providing excellent data-integrity protection at the source and a variable instrument bandwidth capability, this ITP concept represents a significant improvement over present data acquisition procedures. Realignments in the ground telemetry processing functions are described which are intended to take advantage of the ITP concept and to make the data management system more responsive to the scientific investigators.
Swift Burst Alert Telescope (BAT) Instrument Response
NASA Technical Reports Server (NTRS)
Parsons, A.; Hullinger, D.; Markwardt, C.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Krimm, H.; Tueller, J.; Fenimore, E.; Palmer, D.
2004-01-01
The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. In this talk, we describe the BAT instrument response as determined to an accuracy suitable for gamma-ray burst studies. We will also discuss the public data analysis tools developed to calculate the BAT response to sources at different energies and locations in the FOV. The level of accuracy required for the BAT instrument response used for the hard x-ray survey is significantly higher because this response must be used in the iterative clean algorithm for finding fainter sources. Because the bright sources add a lot of coding noise to the BAT sky image, fainter sources can be seen only after the counts due to the bright sources are removed. The better we know the BAT response, the lower the noise in the cleaned spectrum and thus the more sensitive the survey. Since the BAT detector plane consists of 32768 individual, 4 mm square CZT gamma-ray detectors, the most accurate BAT response would include 32768 individual detector response functions to separate mask modulation effects from differences in detector efficiencies! We describe OUT continuing work to improve the accuracy of the BAT instrument response and will present the current results of Monte Carlo simulations as well as BAT ground calibration data.
Smart and functional polymer materials for smart and functional microfluidic instruments
NASA Astrophysics Data System (ADS)
Gray, Bonnie L.
2014-04-01
As microfluidic systems evolve from "chip-in-the-lab" to true portable lab-on-a-chip (LoC) or lab-in-a-package (LiP) microinstrumentation, there is a need for increasingly miniaturized sensors, actuators, and integration/interconnect technologies with high levels of functionality and self-direction. Furthermore, as microfluidic instruments are increasingly realized in polymer-based rather than glass- or silicon- based platforms, there is a need to realize these highly functional components in materials that are polymer-compatible. Polymers that are altered to possess basic functionality, and even higher-functioning "smart" polymer materials, may help to realize high-functioning and selfdirecting portable microinstrumentation. Stimuli-responsive hydrogels have been recognized for over a decade as beneficial to the development of smart microfluidics systems and instrumentation. In addition, functional materials such as conductive and magnetic composite polymers are being increasingly employed to push microfluidics systems to greater degrees of functionality, portability, and/or flexibility for wearable/implantable systems. Functional and smart polymer materials can be employed to realize electrodes, electronic routing, heaters, mixers, valves, pumps, sensors, and interconnect structures in polymer-based microfluidic systems. Stimuli for such materials can be located on-chip or in a small package, thus greatly increasing the degree of portability and the potential for mechanical flexibility of such systems. This paper will examine the application of functional polymer materials to the development of high-functioning microfluidics instruments with a goal towards self-direction.
Creating a Computer Adaptive Test Version of the Late-Life Function & Disability Instrument
Jette, Alan M.; Haley, Stephen M.; Ni, Pengsheng; Olarsch, Sippy; Moed, Richard
2009-01-01
Background This study applied Item Response Theory (IRT) and Computer Adaptive Test (CAT) methodologies to develop a prototype function and disability assessment instrument for use in aging research. Herein, we report on the development of the CAT version of the Late-Life Function & Disability instrument (Late-Life FDI) and evaluate its psychometric properties. Methods We employed confirmatory factor analysis, IRT methods, validation, and computer simulation analyses of data collected from 671 older adults residing in residential care facilities. We compared accuracy, precision, and sensitivity to change of scores from CAT versions of two Late-Life FDI scales with scores from the fixed-form instrument. Score estimates from the prototype CAT versus the original instrument were compared in a sample of 40 older adults. Results Distinct function and disability domains were identified within the Late-Life FDI item bank and used to construct two prototype CAT scales. Using retrospective data, scores from computer simulations of the prototype CAT scales were highly correlated with scores from the original instrument. The results of computer simulation, accuracy, precision, and sensitivity to change of the CATs closely approximated those of the fixed-form scales, especially for the 10- or 15-item CAT versions. In the prospective study each CAT was administered in less than 3 minutes and CAT scores were highly correlated with scores generated from the original instrument. Conclusions CAT scores of the Late-Life FDI were highly comparable to those obtained from the full-length instrument with a small loss in accuracy, precision, and sensitivity to change. PMID:19038841
Rowe, Penny M; Neshyba, Steven P; Walden, Von P
2011-03-14
An analytical expression for the variance of the radiance measured by Fourier-transform infrared (FTIR) emission spectrometers exists only in the limit of low noise. Outside this limit, the variance needs to be calculated numerically. In addition, a criterion for low noise is needed to identify properly calibrated radiances and optimize the instrument bandwidth. In this work, the variance and the magnitude of a noise-dependent spectral bias are calculated as a function of the system responsivity (r) and the noise level in its estimate (σr). The criterion σr/r<0.3, applied to downwelling and upwelling FTIR emission spectra, shows that the instrument bandwidth is specified properly for one instrument but needs to be restricted for another.
Tian, Feng; Ni, Pengsheng; Mulcahey, M J; Hambleton, Ronald K; Tulsky, David; Haley, Stephen M; Jette, Alan M
2014-11-01
To use item response theory (IRT) methods to link scores from 2 recently developed contemporary functional outcome measures, the adult Spinal Cord Injury-Functional Index (SCI-FI) and the Pedi SCI (both the parent version and the child version). Secondary data analysis of the physical functioning items of the adult SCI-FI and the Pedi SCI instruments. We used a nonequivalent group design with items common to both instruments and the Stocking-Lord method for the linking. Linking was conducted so that the adult SCI-FI and Pedi SCI scaled scores could be compared. Community. This study included a total sample of 1558 participants. Pedi SCI items were administered to a sample of children (n=381) with SCI aged 8 to 21 years, and of parents/caregivers (n=322) of children with SCI aged 4 to 21 years. Adult SCI-FI items were administered to a sample of adults (n=855) with SCI aged 18 to 92 years. Not applicable. Five scales common to both instruments were included in the analysis: Wheelchair, Daily Routine/Self-care, Daily Routine/Fine Motor, Ambulation, and General Mobility functioning. Confirmatory factor analysis and exploratory factor analysis results indicated that the 5 scales are unidimensional. A graded response model was used to calibrate the items. Misfitting items were identified and removed from the item banks. Items that function differently between the adult and child samples (ie, exhibit differential item functioning) were identified and removed from the common items used for linking. Domain scores from the Pedi SCI instruments were transformed onto the adult SCI-FI metric. This IRT linking allowed estimation of adult SCI-FI scale scores based on Pedi SCI scale scores and vice versa; therefore, it provides clinicians with a means of tracking long-term functional data for children with an SCI across their entire lifespan. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Altieri, F; Filacchione, G; Capaccioni, F; Carli, C; Dami, M; Tommasi, L; Aroldi, G; Borrelli, D; Barbis, A; Baroni, M; Pastorini, G; Ficai Veltroni, I; Mugnuolo, R
2017-09-01
The Visible and near Infrared Hyperspectral Imager (VIHI) is the VIS-IR spectrometer with imaging capabilities aboard the ESA BepiColombo mission to Mercury. In this second paper, we report the instrument spectral characterization derived by the calibration campaign carried out before spacecraft integration. Complementary measurements concerning radiometric and linearity responses, as well as geometric performances, are described in Paper I [G. Filacchione et al., Rev. Sci. Instrum. 88, 094502 (2017)]. We have verified the VIHI spectral range, spectral dispersion, spectral response function, and spectral uniformity along the whole slit. Instrumental defects and optical aberrations due to smiling and keystone effects have been evaluated, and they are lower than the design requirement (<1/3 pixel). The instrumental response is uniform along the whole slit, while spectral dispersion is well represented by a second order curve, rather than to be constant along the spectral dimension.
NASA Technical Reports Server (NTRS)
Klein, R.
1972-01-01
A set of specially prepared digital tapes is reported which contain synchronized measurements of pilot scanning behavior, control response, and vehicle response obtained during instrument landing system approaches made in a fixed-base DC-8 transport simulator. The objective of the master tape is to provide a common data base which can be used by the research community to test theories, models, and methods for describing and analyzing control/display relations and interactions. The experimental conditions and tasks used to obtain the data and the detailed format of the tapes are described. Conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Continuous pilot eye fixations and scan traffic on the panel were measured. Both flight director and standard localizer/glide slope types of approaches were made, with both fixed and variable instrument range sensitivities.
ERIC Educational Resources Information Center
Mbachu, Comfort Ebere; Dorgu, Theresa Ebiere
2014-01-01
Education is seen as an instrument "per excellence" for effecting national development. Education is seen as a means of developing potentialities and capacity building. Any educational Curriculum that aims at developing human potentials must target at functionality. Functionality here refers to curriculum that is designed to teach…
Instrument performance enhancement and modification through an extended instrument paradigm
NASA Astrophysics Data System (ADS)
Mahan, Stephen Lee
An extended instrument paradigm is proposed, developed and shown in various applications. The CBM (Chin, Blass, Mahan) method is an extension to the linear systems model of observing systems. In the most obvious and practical application of image enhancement of an instrument characterized by a time-invariant instrumental response function, CBM can be used to enhance images or spectra through a simple convolution application of the CBM filter for a resolution improvement of as much as a factor of two. The CBM method can be used in many applications. We discuss several within this work including imaging through turbulent atmospheres, or what we've called Adaptive Imaging. Adaptive Imaging provides an alternative approach for the investigator desiring results similar to those obtainable with adaptive optics, however on a minimal budget. The CBM method is also used in a backprojected filtered image reconstruction method for Positron Emission Tomography. In addition, we can use information theoretic methods to aid in the determination of model instrumental response function parameters for images having an unknown origin. Another application presented herein involves the use of the CBM method for the determination of the continuum level of a Fourier transform spectrometer observation of ethylene, which provides a means for obtaining reliable intensity measurements in an automated manner. We also present the application of CBM to hyperspectral image data of the comet Shoemaker-Levy 9 impact with Jupiter taken with an acousto-optical tunable filter equipped CCD camera to an adaptive optics telescope.
Visual-Accommodation Trainer/Tester
NASA Technical Reports Server (NTRS)
Randle, Robert J., Jr.
1986-01-01
Ophthalmic instrument tests and helps develop focusing ability. Movable stage on a fixed base permits adjustment of effective target position as perceived by subject. Various apertures used to perform tests and training procedures. Ophthalmic instrument provides four functions: it measures visual near and far points; provides focus stimulus in vision research; measures visual-accommodation resting position; can be used to train for volitional control of person's focus response.
NASA Technical Reports Server (NTRS)
Remer, Lorraine A.; Lau, William (Technical Monitor)
2002-01-01
The PRIDE data set of MODIS aerosol retrievals co-located with sunphotometer measurements provides the basis of MODIS validation in a dust environment. The sunphotometer measurements include AERONET automatic instruments, land-based Microtops instruments, ship-board Microtops instruments and the AATS-6 aboard the Navajo aircraft. Analysis of these data indicate that the MODIS retrieval is within pre-launch estimates of uncertainty within the spectral range of 600-900 nm. However, the MODIS algorithm consistently retrieves smaller particles than reality thus leading to incorrect spectral response outside of the 600-900 nm range and improper size information. Further analysis of MODIS retrievals in other dust environments shows the inconsistencies are due to nonspherical effects in the phase function. These data are used to develop an ambient phase function for dust aerosol to be used for remote sensing purposes.
Evaluation of impairment of the upper extremity.
Blair, S J; McCormick, E; Bear-Lehman, J; Fess, E E; Rader, E
1987-08-01
Evaluation of impairment of the upper extremity is the product of a team effort by the physician, occupational therapist, physical therapist, and rehabilitation counselor. A careful recording of the anatomic impairment should be made because this is critical in determining the subsequent functional activities of the extremity. The measurement criteria for clinical and functional evaluation includes condition assessment instruments. Some assess the neurovascular system, others assess movements including the monitoring of articular motion and musculotendinous function. Sensibility assessment instruments measure sympathetic response and detect single joint stimulus, discrimination, quantification, and recognition abilities. A detailed description of each assessment is recorded and physical capacity evaluation is only one component of the entire vocational evaluation. This evaluation answers questions regarding the injured worker's ability to return to his previous job. The work simulator is a useful instrument that allows rehabilitation and testing of the injured upper extremity. Job site evaluation includes assessment criteria for work performance, work behavior, and work environment.
Application of Least Mean Square Algorithms to Spacecraft Vibration Compensation
NASA Technical Reports Server (NTRS)
Woodard , Stanley E.; Nagchaudhuri, Abhijit
1998-01-01
This paper describes the application of the Least Mean Square (LMS) algorithm in tandem with the Filtered-X Least Mean Square algorithm for controlling a science instrument's line-of-sight pointing. Pointing error is caused by a periodic disturbance and spacecraft vibration. A least mean square algorithm is used on-orbit to produce the transfer function between the instrument's servo-mechanism and error sensor. The result is a set of adaptive transversal filter weights tuned to the transfer function. The Filtered-X LMS algorithm, which is an extension of the LMS, tunes a set of transversal filter weights to the transfer function between the disturbance source and the servo-mechanism's actuation signal. The servo-mechanism's resulting actuation counters the disturbance response and thus maintains accurate science instrumental pointing. A simulation model of the Upper Atmosphere Research Satellite is used to demonstrate the algorithms.
Dynamic studies of small animals with a four-color diffuse optical tomography imager
NASA Astrophysics Data System (ADS)
Schmitz, Christoph H.; Graber, Harry L.; Pei, Yaling; Farber, Mark; Stewart, Mark; Levina, Rita D.; Levin, Mikhail B.; Xu, Yong; Barbour, Randall L.
2005-09-01
We present newly developed instrumentation for full-tomographic four-wavelength, continuous wave, diffuse optical tomography (DOT) imaging on small animals. A small-animal imaging stage was constructed, from materials compatible with in-magnet studies, which offers stereotaxic fixation of the animal and precise, stable probe positioning. Instrument performance, based on calibration and phantom studies, demonstrates excellent long-term signal stability. DOT measurements of the functional rat brain response to electric paw stimulation are presented, and these demonstrate high data quality and excellent sensitivity to hemodynamic changes. A general linear model analysis on individual trials is used to localize and quantify the occurrence of functional behavior associated with the different hemoglobin state responses. Statistical evaluation of outcomes of individual trials is employed to identify significant regional response variations for different stimulation sites. Image results reveal a diffuse cortical response and a strong reaction of the thalamus, both indicative of activation of pain pathways by the stimulation. In addition, a weaker lateralized functional component is observed in the brain response, suggesting presence of motor activation. An important outcome of the experiment is that it shows that reactions to individual provocations can be monitored, without having to resort to signal averaging. Thus the described technology may be useful for studies of long-term trends in hemodynamic response, as would occur, for example, in behavioral studies involving freely moving animals.
Development of the Computer-Adaptive Version of the Late-Life Function and Disability Instrument
Tian, Feng; Kopits, Ilona M.; Moed, Richard; Pardasaney, Poonam K.; Jette, Alan M.
2012-01-01
Background. Having psychometrically strong disability measures that minimize response burden is important in assessing of older adults. Methods. Using the original 48 items from the Late-Life Function and Disability Instrument and newly developed items, a 158-item Activity Limitation and a 62-item Participation Restriction item pool were developed. The item pools were administered to a convenience sample of 520 community-dwelling adults 60 years or older. Confirmatory factor analysis and item response theory were employed to identify content structure, calibrate items, and build the computer-adaptive testings (CATs). We evaluated real-data simulations of 10-item CAT subscales. We collected data from 102 older adults to validate the 10-item CATs against the Veteran’s Short Form-36 and assessed test–retest reliability in a subsample of 57 subjects. Results. Confirmatory factor analysis revealed a bifactor structure, and multi-dimensional item response theory was used to calibrate an overall Activity Limitation Scale (141 items) and an overall Participation Restriction Scale (55 items). Fit statistics were acceptable (Activity Limitation: comparative fit index = 0.95, Tucker Lewis Index = 0.95, root mean square error approximation = 0.03; Participation Restriction: comparative fit index = 0.95, Tucker Lewis Index = 0.95, root mean square error approximation = 0.05). Correlation of 10-item CATs with full item banks were substantial (Activity Limitation: r = .90; Participation Restriction: r = .95). Test–retest reliability estimates were high (Activity Limitation: r = .85; Participation Restriction r = .80). Strength and pattern of correlations with Veteran’s Short Form-36 subscales were as hypothesized. Each CAT, on average, took 3.56 minutes to administer. Conclusions. The Late-Life Function and Disability Instrument CATs demonstrated strong reliability, validity, accuracy, and precision. The Late-Life Function and Disability Instrument CAT can achieve psychometrically sound disability assessment in older persons while reducing respondent burden. Further research is needed to assess their ability to measure change in older adults. PMID:22546960
NASA Technical Reports Server (NTRS)
Esposito, J. A.; Bertsch, D. L.; Chen, A. W.; Dingus, B. L.; Fichtel, C. E.; Hartman, R. C.; Hunter, S. D.; Kanbach, G.; Kniffen, D. A.; Lin, Y. C.;
1998-01-01
The Energetic Gamma-Ray Experiment Telescope (EGRET) on the Compton Gamma-Ray Observatory has been operating for over seven years since its launch in 1991 April. This span of time far exceeds the design lifetime of two years. As the instrument has aged, several changes have occurred due to spark chamber gas exchanges as well as some hardware degradation and failures, all of which have an influence on the instrument sensitivity. This paper describes post-launch measurements and analysis that are done to calibrate the instrument response functions. The updated instrument characteristics are incorporated into the analysis software.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, X. Y.; Chen, Z. J.; Zhang, X.
The 2.5 MeV neutron spectrometer TOFED (Time-Of-Flight Enhanced Diagnostics) has been constructed to perform advanced neutron emission spectroscopy diagnosis of deuterium plasmas on EAST. The instrument has a double-ring structure which, in combination with pulse shape digitization, allows for a dual kinematic selection in the time-of-flight/recoil proton energy (tof/E{sub p}) space, thus improving the spectrometer capability to resolve fast ion signatures in the neutron spectrum, in principle up to a factor ≈100. The identification and separation of features from the energetic ions in the neutron spectrum depends on the detailed knowledge of the instrument response function, both in terms ofmore » the light output function of the scintillators and the effect of undesired multiple neutron scatterings in the instrument. This work presents the determination of the light output function of the TOFED plastic scintillator detectors and their geometrical assembly. Results from dedicated experiments with γ-ray sources and quasi-monoenergetic neutron beams are presented. Implications on the instrument capability to perform background suppression based on double kinematic selection are discussed.« less
The 1995 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers
Early, Edward; Thompson, Ambler; Johnson, Carol; DeLuisi, John; Disterhoft, Patrick; Wardle, David; Wu, Edmund; Mou, Wanfeng; Sun, Yongchen; Lucas, Timothy; Mestechkina, Tanya; Harrison, Lee; Berndt, Jerry; Hayes, Douglas S.
1998-01-01
Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the second North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held June 12 to 23, 1995 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology (NIST) and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency; the National Science Foundation; the Smithsonian Environmental Research Center; the Department of Agriculture; and the Atmospheric Environment Service, Canada. Instruments were characterized for wavelength uncertainty, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with a NIST standard lamp operating in a specially designed field calibration unit. The spectral irradiance responsivity, determined once indoors and twice outdoors, demonstrated that while the responsivities changed upon moving the instruments, they were relatively stable when the instruments remained outdoors. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamp and three different convolution functions to account for the different bandwidths of the instruments, the measured solar irradiances generally agreed to within 3 %. PMID:28009371
MIT Participation in the Data Analysis of the XRS and XIS Instruments on the Astro-E2 Mission
NASA Technical Reports Server (NTRS)
Bautz, Mark
2005-01-01
Since the inception of this grant six weeks ago, we have completed the initial activation of the Suzaku X-ray Imaging Spectrometer (XIS) (on 13 August) and we have supported initial calibration observations. The instrument is performing very well in all respects. We have characterized the spectral resolution and effective area of each XIS sensor. We are especially excited about the scientific opportunities provided by the XIS'S back- illuminated sensor, which exhibits spectral resolution in the sub-keV band unmatched by any X-ray CCD currently in orbit. As specified in our proposal, we have established a web site (http://space.mit.edu/XIS) on which we maintain an up-to-date summary of instrument performance characteristics. Gain, spectral resolution and system noise, as well as residual background rates, are currently available on this site. Although the particle background level is low compared with Chandra and XMM, we are currently evaluating methods to reduce it still further. Techniques under study include use of 5x5 mode information and alternative grade selection methods. Although the primary responsibility for development of instrument response functions rests with our Japanese colleagues, we are incorporating our latest measurements of spectral resolution into some temporary response functions which we hope to make available to the Suzaku General Observer Facility and the Science Working Group(SWG). We are also preparing proposals for use of SWG observing time.
NASA Astrophysics Data System (ADS)
Luchowski, R.; Kapusta, P.; Szabelski, M.; Sarkar, P.; Borejdo, J.; Gryczynski, Z.; Gryczynski, I.
2009-09-01
Förster resonance energy transfer (FRET) can be utilized to achieve ultrashort fluorescence responses in time-domain fluorometry. In a poly(vinyl) alcohol matrix, the presence of 60 mM Rhodamine 800 acceptor shortens the fluorescence lifetime of a pyridine 1 donor to about 20 ps. Such a fast fluorescence response is very similar to the instrument response function (IRF) obtained using scattered excitation light. A solid fluorescent sample (e.g a film) with picosecond lifetime is ideal for IRF measurements and particularly useful for time-resolved microscopy. Avalanche photodiode detectors, commonly used in this field, feature color- dependent-timing responses. We demonstrate that recording the fluorescence decay of the proposed FRET-based reference sample yields a better IRF approximation than the conventional light-scattering method and therefore avoids systematic errors in decay curve analysis.
NASA Astrophysics Data System (ADS)
Ninkov, Zoran
Stellar images taken with telescopes and detectors in space are usually undersampled, and to correct for this, an accurate pixel response function is required. The standard approach for HST and KEPLER has been to measure the telescope PSF combined ("convolved") with the actual pixel response function, super-sampled by taking into account dithered or offset observed images of many stars (Lauer [1999]). This combined response function has been called the "PRF" (Bryson et al. [2011]). However, using such results has not allowed astrometry from KEPLER to reach its full potential (Monet et al. [2010], [2014]). Given the precision of KEPLER photometry, it should be feasible to use a pre-determined detector pixel response function (PRF) and an optical point spread function (PSF) as separable quantities to more accurately correct photometry and astrometry for undersampling. Wavelength (i.e. stellar color) and instrumental temperature should be affecting each of these differently. Discussion of the PRF in the "KEPLER Instrument Handbook" is limited to an ad-hoc extension of earlier measurements on a quite different CCD. It is known that the KEPLER PSF typically has a sharp spike in the middle, and the main bulk of the PSF is still small enough to be undersampled, so that any substructure in the pixel may interact significantly with the optical PSF. Both the PSF and PRF are probably asymmetric. We propose to measure the PRF for an example of the CCD sensors used on KEPLER at sufficient sampling resolution to allow significant improvement of KEPLER photometry and astrometry, in particular allowing PSF fitting techniques to be used on the data archive.
Barei, David P; Agel, Julie; Swiontkowski, Marc F
2007-01-01
The development of patient-oriented health status measurements has resulted in the emergence of several generic condition-specific and anatomic-specific instruments. These instruments are generally designed to measure the function of the individual as a whole from the individual's own point of view. They are not intended to replace traditional physician-oriented clinical outcome measures, such as complication rates, ranges of motion, or time to fracture union; instead, they are an attempt to measure the results of a treatment or condition from the patient's perspective. Over the past decade, the Musculoskeletal Function Assessment (MFA) instrument has been developed and used as one of the primary generic musculoskeletal functional assessment tools, in part because of its validity, reliability, and responsiveness. Despite the numerous publications reporting the MFA/SMFA, we are unaware of any publications that have used those results to subsequently affect patient care. We hope that this special interest article highlights the current underutilization of the available data and encourages the orthopedic community to maximize the clinical and research potential of the MFA/SMFA (Short Musculoskeletal Function Assessment).
The three principles of action: a Pavlovian-instrumental transfer hypothesis
Cartoni, Emilio; Puglisi-Allegra, Stefano; Baldassarre, Gianluca
2013-01-01
Pavlovian conditioned stimuli can influence instrumental responding, an effect called Pavlovian-instrumental transfer (PIT). During the last decade, PIT has been subdivided into two types: specific PIT and general PIT, each having its own neural substrates. Specific PIT happens when a conditioned stimulus (CS) associated with a reward enhances an instrumental response directed to the same reward. Under general PIT, instead, the CS enhances a response directed to a different reward. While important progress has been made into identifying the neural substrates, the function of specific and general PIT and how they interact with instrumental responses are still not clear. In the experimental paradigm that distinguishes specific and general PIT an effect of PIT inhibition has also been observed and is waiting for an explanation. Here we propose an hypothesis that links these three PIT effects (specific PIT, general PIT and PIT inhibition) to three aspects of action evaluation. These three aspects, which we call “principles of action”, are: context, efficacy, and utility. In goal-directed behavior, an agent has to evaluate if the context is suitable to accomplish the goal, the efficacy of his action in getting the goal, and the utility of the goal itself: we suggest that each of the three PIT effects is related to one of these aspects of action evaluation. In particular, we link specific PIT with the estimation of efficacy, general PIT with the evaluation of utility, and PIT inhibition with the adequacy of context. We also provide a latent cause Bayesian computational model that exemplifies this hypothesis. This hypothesis and the model provide a new framework and new predictions to advance knowledge about PIT functioning and its role in animal adaptation. PMID:24312025
The Impact of Missing Data on the Detection of Nonuniform Differential Item Functioning
ERIC Educational Resources Information Center
Finch, W. Holmes
2011-01-01
Missing information is a ubiquitous aspect of data analysis, including responses to items on cognitive and affective instruments. Although the broader statistical literature describes missing data methods, relatively little work has focused on this issue in the context of differential item functioning (DIF) detection. Such prior research has…
Seoane, Fernando; Ferreira, Javier; Alvarez, Lorena; Buendia, Ruben; Ayllón, David; Llerena, Cosme; Gil-Pita, Roberto
2013-01-01
Advances in textile materials, technology and miniaturization of electronics for measurement instrumentation has boosted the development of wearable measurement systems. In several projects sensorized garments and non-invasive instrumentation have been integrated to assess on emotional, cognitive responses as well as physical arousal and status of mental stress through the study of the autonomous nervous system. Assessing the mental state of workers under stressful conditions is critical to identify which workers are in the proper state of mind and which are not ready to undertake a mission, which might consequently risk their own life and the lives of others. The project Assessment in Real Time of the Stress in Combatants (ATREC) aims to enable real time assessment of mental stress of the Spanish Armed Forces during military activities using a wearable measurement system containing sensorized garments and textile-enabled non-invasive instrumentation. This work describes the multiparametric sensorized garments and measurement instrumentation implemented in the first phase of the project required to evaluate physiological indicators and recording candidates that can be useful for detection of mental stress. For such purpose different sensorized garments have been constructed: a textrode chest-strap system with six repositionable textrodes, a sensorized glove and an upper-arm strap. The implemented textile-enabled instrumentation contains one skin galvanometer, two temperature sensors for skin and environmental temperature and an impedance pneumographer containing a 1-channel ECG amplifier to record cardiogenic biopotentials. With such combinations of garments and non-invasive measurement devices, a multiparametric wearable measurement system has been implemented able to record the following physiological parameters: heart and respiration rate, skin galvanic response, environmental and peripheral temperature. To ensure the proper functioning of the implemented garments and devices the full series of 12 sets have been functionally tested recording cardiogenic biopotential, thoracic impedance, galvanic skin response and temperature values. The experimental results indicate that the implemented wearable measurement systems operate according to the specifications and are ready to be used for mental stress experiments, which will be executed in the coming phases of the project with dozens of healthy volunteers. PMID:23857264
Seoane, Fernando; Ferreira, Javier; Alvarez, Lorena; Buendia, Ruben; Ayllón, David; Llerena, Cosme; Gil-Pita, Roberto
2013-07-12
Advances in textile materials, technology and miniaturization of electronics for measurement instrumentation has boosted the development of wearable measurement systems. In several projects sensorized garments and non-invasive instrumentation have been integrated to assess on emotional, cognitive responses as well as physical arousal and status of mental stress through the study of the autonomous nervous system. Assessing the mental state of workers under stressful conditions is critical to identify which workers are in the proper state of mind and which are not ready to undertake a mission, which might consequently risk their own life and the lives of others. The project Assessment in Real Time of the Stress in Combatants (ATREC) aims to enable real time assessment of mental stress of the Spanish Armed Forces during military activities using a wearable measurement system containing sensorized garments and textile-enabled non-invasive instrumentation. This work describes the multiparametric sensorized garments and measurement instrumentation implemented in the first phase of the project required to evaluate physiological indicators and recording candidates that can be useful for detection of mental stress. For such purpose different sensorized garments have been constructed: a textrode chest-strap system with six repositionable textrodes, a sensorized glove and an upper-arm strap. The implemented textile-enabled instrumentation contains one skin galvanometer, two temperature sensors for skin and environmental temperature and an impedance pneumographer containing a 1-channel ECG amplifier to record cardiogenic biopotentials. With such combinations of garments and non-invasive measurement devices, a multiparametric wearable measurement system has been implemented able to record the following physiological parameters: heart and respiration rate, skin galvanic response, environmental and peripheral temperature. To ensure the proper functioning of the implemented garments and devices the full series of 12 sets have been functionally tested recording cardiogenic biopotential, thoracic impedance, galvanic skin response and temperature values. The experimental results indicate that the implemented wearable measurement systems operate according to the specifications and are ready to be used for mental stress experiments, which will be executed in the coming phases of the project with dozens of healthy volunteers.
Temporal variations in Global Seismic Stations ambient noise power levels
Ringler, A.T.; Gee, L.S.; Hutt, C.R.; McNamara, D.E.
2010-01-01
Recent concerns about time-dependent response changes in broadband seismometers have motivated the need for methods to monitor sensor health at Global Seismographic Network (GSN) stations. We present two new methods for monitoring temporal changes in data quality and instrument response transfer functions that are independent of Earth seismic velocity and attenuation models by comparing power levels against different baseline values. Our methods can resolve changes in both horizontal and vertical components in a broad range of periods (∼0.05 to 1,000 seconds) in near real time. In this report, we compare our methods with existing techniques and demonstrate how to resolve instrument response changes in long-period data (>100 seconds) as well as in the microseism bands (5 to 20 seconds).
Fries, J F; Bruce, B; Bjorner, J; Rose, M
2006-01-01
Objectives Patient reported outcomes (PROs) have become standard study endpoints. However, little attention has been given to using item improvement to advance PRO performance which could improve precision, clarity, patient relevance, and information content of “physical function/disability” items and thus the performance of resulting instruments. Methods The present study included1860 physical function/disability items from 165 instruments. Item formulations were assessed by frequency of use, modified Delphi consensus, respondent judgement of clarity and importance, and item response theory (IRT). Data from 1100 rheumatoid arthritis, osteoarthritis, and normal ageing subjects, using qualitative item review, focus groups, cognitive interviews, and patient survey were used to achieve a unique item pool that was clear, reliable, sensitive to change, readily translatable, devoid of floor and ceiling limitations, contained unidimensional subdomains, and had maximal information content. Results A “present tense” time frame was used most frequently, better understood, more readily translated, and more directly estimated the latent trait of disability. Items in the “past tense” had 80–90% false negatives (p<0.001). The best items were brief, clear, and contained a single construct. Responses with four to five options were preferred by both experts and respondents. The term physical function may be preferable to the term disability because of fewer floor effects. IRT analyses of “disability” suggest four independent subdomains (mobility, dexterity, axial, and compound) with factor loadings of 0.81–0.99. Conclusions Major improvement in performance of items and instruments is possible, and may have the effect of substantially reducing sample size requirements for clinical trials. PMID:17038464
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.
2001-01-01
Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.
Using Model-Based Reasoning for Autonomous Instrument Operation - Lessons Learned From IMAGE/LENA
NASA Technical Reports Server (NTRS)
Johnson, Michael A.; Rilee, Michael L.; Truszkowski, Walt; Bailin, Sidney C.
2001-01-01
Model-based reasoning has been applied as an autonomous control strategy on the Low Energy Neutral Atom (LENA) instrument currently flying on board the Imager for Magnetosphere-to-Aurora Global Exploration (IMAGE) spacecraft. Explicit models of instrument subsystem responses have been constructed and are used to dynamically adapt the instrument to the spacecraft's environment. These functions are cast as part of a Virtual Principal Investigator (VPI) that autonomously monitors and controls the instrument. In the VPI's current implementation, LENA's command uplink volume has been decreased significantly from its previous volume; typically, no uplinks are required for operations. This work demonstrates that a model-based approach can be used to enhance science instrument effectiveness. The components of LENA are common in space science instrumentation, and lessons learned by modeling this system may be applied to other instruments. Future work involves the extension of these methods to cover more aspects of LENA operation and the generalization to other space science instrumentation.
Statistical methods for biodosimetry in the presence of both Berkson and classical measurement error
NASA Astrophysics Data System (ADS)
Miller, Austin
In radiation epidemiology, the true dose received by those exposed cannot be assessed directly. Physical dosimetry uses a deterministic function of the source term, distance and shielding to estimate dose. For the atomic bomb survivors, the physical dosimetry system is well established. The classical measurement errors plaguing the location and shielding inputs to the physical dosimetry system are well known. Adjusting for the associated biases requires an estimate for the classical measurement error variance, for which no data-driven estimate exists. In this case, an instrumental variable solution is the most viable option to overcome the classical measurement error indeterminacy. Biological indicators of dose may serve as instrumental variables. Specification of the biodosimeter dose-response model requires identification of the radiosensitivity variables, for which we develop statistical definitions and variables. More recently, researchers have recognized Berkson error in the dose estimates, introduced by averaging assumptions for many components in the physical dosimetry system. We show that Berkson error induces a bias in the instrumental variable estimate of the dose-response coefficient, and then address the estimation problem. This model is specified by developing an instrumental variable mixed measurement error likelihood function, which is then maximized using a Monte Carlo EM Algorithm. These methods produce dose estimates that incorporate information from both physical and biological indicators of dose, as well as the first instrumental variable based data-driven estimate for the classical measurement error variance.
NASA Astrophysics Data System (ADS)
Crawford, C. J.; Chickadel, C. C.; Hall, D. K.; Jennings, D. E.; Jhabvala, M. D.; Kim, E. J.; Jessica, L.; Lunsford, A.
2017-12-01
The NASA Terrestrial Hydrology Program sponsored a ground and airborne snow experiment (SnowEx) to the Grand Mesa area and Senator Beck Basin in western Colorado during February 2017. This communication summarizes efforts to develop traceable instrument calibration requirements for SnowEx Grand Mesa in support of thermal infrared (TIR) and visible-to-shortwave infrared (VSWIR) snow measurement science. Cross-calibration outcomes for TIR instruments (7-10 µm and 8-14 µm response functions) indicate that an at-sensor measurement accuracy of within 1.5 degrees Celsius was achieved across ground and airborne sensors using laboratory and field blackbody sources. A cross-calibration assessment of VSWIR spectrometers (0.35 to 2.5 µm response functions) using a National Institutes of Standard Technology (NIST) traceable source indicates an at-sensor measurement accuracy of within 5% for visible-near infrared spectral radiance (W/cm-2/sr-1/nm) and irradiance (W/m-2/nm), and within 20% for shortwave infrared measurements before a radiometric cross-calibration correction was applied. Additional validation is undertaken to assess the ground and airborne SnowEx Grand Mesa TIR and VSWIR instrument cross-calibration quality by benchmarking against on-orbit image acquisitions of the snow surface on February 14th and 15th, 2017 from Landsat Enhanced Thematic Mapper Plus (ETM+), Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), and Sentinel-2A Multi-Spectral Instrument (MSI).
NASA's Applied Sciences: Natural Disasters Program
NASA Technical Reports Server (NTRS)
Kessler, Jason L.
2010-01-01
Fully utilize current and near-term airborne and spaceborne assets and capabilities. NASA spaceborne instruments are for research but can be applied to natural disaster response as appropriate. NASA airborne instruments can be targeted specifically for disaster response. Could impact research programs. Better flow of information improves disaster response. Catalog capability, product, applicable disaster, points of contact. Ownership needs to come from the highest level of NASA - unpredictable and irregular nature of disasters requires contingency funding for disaster response. Build-in transfer of applicable natural disaster research capabilities to operational functionality at other agencies (e.g., USFS, NOAA, FEMA...) at the outset, whenever possible. For the Decadal Survey Missions, opportunities exist to identify needs and requirements early in the mission design process. Need to understand additional needs and commitments for meeting the needs of the disaster community. Opportunity to maximize disaster response and mitigation from the Decadal Survey Missions. Additional needs or capabilities may require agency contributions.
Measuring Workplace Climate in Community Clinics and Health Centers.
Friedberg, Mark W; Rodriguez, Hector P; Martsolf, Grant R; Edelen, Maria O; Vargas Bustamante, Arturo
2016-10-01
The effectiveness of community clinics and health centers' efforts to improve the quality of care might be modified by clinics' workplace climates. Several surveys to measure workplace climate exist, but their relationships to each other and to distinguishable dimensions of workplace climate are unknown. To assess the psychometric properties of a survey instrument combining items from several existing surveys of workplace climate and to generate a shorter instrument for future use. We fielded a 106-item survey, which included items from 9 existing instruments, to all clinicians and staff members (n=781) working in 30 California community clinics and health centers, receiving 628 responses (80% response rate). We performed exploratory factor analysis of survey responses, followed by confirmatory factor analysis of 200 reserved survey responses. We generated a new, shorter survey instrument of items with strong factor loadings. Six factors, including 44 survey items, emerged from the exploratory analysis. Two factors (Clinic Workload and Teamwork) were independent from the others. The remaining 4 factors (staff relationships, quality improvement orientation, managerial readiness for change, and staff readiness for change) were highly correlated, indicating that these represented dimensions of a higher-order factor we called "Clinic Functionality." This 2-level, 6-factor model fit the data well in the exploratory and confirmatory samples. For all but 1 factor, fewer than 20 survey responses were needed to achieve clinic-level reliability >0.7. Survey instruments designed to measure workplace climate have substantial overlap. The relatively parsimonious item set we identified might help target and tailor clinics' quality improvement efforts.
Measuring Workplace Climate in Community Clinics and Health Centers
Friedberg, Mark W.; Rodriguez, Hector P.; Martsolf, Grant; Edelen, Maria Orlando; Vargas-Bustamante, Arturo
2018-01-01
Background The effectiveness of community clinics and health centers’ efforts to improve the quality of care might be modified by clinics’ workplace climates. Several surveys to measure workplace climate exist, but their relationships to each other and to distinguishable dimensions of workplace climate are unknown. Objective To assess the psychometric properties of a survey instrument combining items from several existing surveys of workplace climate and to generate a shorter instrument for future use. Methods We fielded a 106-item survey, which included items from 9 existing instruments, to all clinicians and staff members (n=781) working in 30 California community clinics and health centers, receiving 628 responses (80% response rate). We performed exploratory factor analysis of survey responses, followed by confirmatory factor analysis of 200 reserved survey responses. We generated a new, shorter survey instrument of items with strong factor loadings. Results Six factors, including 44 survey items, emerged from the exploratory analysis. Two factors (Clinic Workload and Teamwork) were independent from the others. The remaining 4 factors (Staff Relationships, Quality Improvement Orientation, Managerial Readiness for Change, and Staff Readiness for Change) were highly correlated, indicating that these represented dimensions of a higher-order factor we called “Clinic Functionality.” This two-level, six-factor model fit the data well in the exploratory and confirmatory samples. For all but one factor, fewer than 20 survey responses were needed to achieve clinic-level reliability >0.7. Conclusion Survey instruments designed to measure workplace climate have substantial overlap. The relatively parsimonious item set we identified might help target and tailor clinics’ quality improvement efforts. PMID:27326549
NASA Technical Reports Server (NTRS)
Delp, P.; Crossman, E. R. F. W.; Szostak, H.
1972-01-01
The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.
Core outcome measurement instruments for clinical trials in nonspecific low back pain
Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A.; Buchbinder, Rachelle; Corbin, Terry P.; Costa, Leonardo O.P.; Foster, Nadine E.; Grotle, Margreth; Koes, Bart W.; Kovacs, Francisco M.; Lin, C.-W. Christine; Maher, Chris G.; Pearson, Adam M.; Peul, Wilco C.; Schoene, Mark L.; Turk, Dennis C.; van Tulder, Maurits W.; Terwee, Caroline B.; Ostelo, Raymond W.
2018-01-01
Abstract To standardize outcome reporting in clinical trials of patients with nonspecific low back pain, an international multidisciplinary panel recommended physical functioning, pain intensity, and health-related quality of life (HRQoL) as core outcome domains. Given the lack of a consensus on measurement instruments for these 3 domains in patients with low back pain, this study aimed to generate such consensus. The measurement properties of 17 patient-reported outcome measures for physical functioning, 3 for pain intensity, and 5 for HRQoL were appraised in 3 systematic reviews following the COSMIN methodology. Researchers, clinicians, and patients (n = 207) were invited in a 2-round Delphi survey to generate consensus (≥67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In round 1, consensus was achieved on the Oswestry Disability Index version 2.1a for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In round 2, a consensus was reached on an NRS version with a 1-week recall period (96% agreement). Various participants requested 1 free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: Oswestry Disability Index version 2.1a or 24-item Roland-Morris Disability Questionnaire for physical functioning, NRS for pain intensity, and SF12 or 10-item PROMIS Global Health form for HRQoL. Further studies need to fill the evidence gaps on the measurement properties of these and other instruments. PMID:29194127
[Quenched fluorescein: a reference dye for instrument response function of TCSPC].
Pan, Hai-feng; Ding, Jing-xin; Liang, Rong-rong; Tao, Zhan-dong; Liu, Meng-wei; Zhang, San-jun; Xu, Jian-hua
2014-08-01
Measuring the instrument response function (IRF) and fitting by reconvolution algorithms are routines to improve time resolution in fluorescence lifetime measurements. Iodide ions were successfully used to quench the fluorescence of fluorescein in this study. By systematically adding saturated NaI water solution in basic fluorescein solution, the lifetimes of fluorescein were reduced from 4 ns to 24 ps. The quenched lifetime of fluorescein obtained from the analysis of Time-Correlated Single Photon Counting (TCSPC) measurement agrees well with that from femtosecond frequency up-conversion measurement. In time resolved excitation spectra measurements, the IRF should be measured at various detection wavelengths providing scattring materials are used. This study could not only reduce the complexity of IRF measurement, but also avoid the existing color effect in system. This study should have wide applications in time resolved fluorescence spectroscopy and fluorescence lifetime imaging.
End-to-end test of the electron-proton spectrometer
NASA Technical Reports Server (NTRS)
Cash, B. L.
1972-01-01
A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.
Psychometric Principles in Measurement for Geoscience Education Research: A Climate Change Example
NASA Astrophysics Data System (ADS)
Libarkin, J. C.; Gold, A. U.; Harris, S. E.; McNeal, K.; Bowles, R.
2015-12-01
Understanding learning in geoscience classrooms requires that we use valid and reliable instruments aligned with intended learning outcomes. Nearly one hundred instruments assessing conceptual understanding in undergraduate science and engineering classrooms (often called concept inventories) have been published and are actively being used to investigate learning. The techniques used to develop these instruments vary widely, often with little attention to psychometric principles of measurement. This paper will discuss the importance of using psychometric principles to design, evaluate, and revise research instruments, with particular attention to the validity and reliability steps that must be undertaken to ensure that research instruments are providing meaningful measurement. An example from a climate change inventory developed by the authors will be used to exemplify the importance of validity and reliability, including the value of item response theory for instrument development. A 24-item instrument was developed based on published items, conceptions research, and instructor experience. Rasch analysis of over 1000 responses provided evidence for the removal of 5 items for misfit and one item for potential bias as measured via differential item functioning. The resulting 18-item instrument can be considered a valid and reliable measure based on pre- and post-implementation metrics. Consideration of the relationship between respondent demographics and concept inventory scores provides unique insight into the relationship between gender, religiosity, values and climate change understanding.
The analysis and interpretation of very-long-period seismic signals on volcanoes
NASA Astrophysics Data System (ADS)
Sindija, Dinko; Neuberg, Jurgen; Smith, Patrick
2017-04-01
The study of very long period (VLP) seismic signals became possible with the widespread use of broadband instruments. VLP seismic signals are caused by transients of pressure in the volcanic edifice and have periods ranging from several seconds to several minutes. For the VLP events recorded in March 2012 and 2014 at Soufriere Hills Volcano, Montserrat, we model the ground displacement using several source time functions: a step function using Richards growth equation, Küpper wavelet, and a damped sine wave to which an instrument response is then applied. This way we get a synthetic velocity seismogram which is directly comparable to the data. After the full vector field of ground displacement is determined, we model the source mechanism to determine the relationship between the source mechanism and the observed VLP waveforms. Emphasis of the research is on how different VLP waveforms are related to the volcano environment and the instrumentation used and on the processing steps in this low frequency band to get most out of broadband instruments.
Lantz, Kathleen; Disterhoft, Patrick; Early, Edward; Thompson, Ambler; DeLuisi, John; Berndt, Jerry; Harrison, Lee; Kiedron, Peter; Ehramjian, James; Bernhard, Germar; Cabasug, Lauriana; Robertson, James; Mou, Wanfeng; Taylor, Thomas; Slusser, James; Bigelow, David; Durham, Bill; Janson, George; Hayes, Douglass; Beaubien, Mark; Beaubien, Arthur
2002-01-01
The fourth North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 15 to 25, 1997 at Table Mountain outside of Boulder, Colorado, USA. Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. The main purpose of the Intercomparison was to assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks. This Intercomparison was coordinated by NIST and NOAA, and included participants from the ASRC, EPA, NIST, NSF, SERC, USDA, and YES. The UV measuring instruments included scanning spectroradiometers, spectrographs, narrow band multi-filter radiometers, and broadband radiometers. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity. The spectral irradiance responsivity was determined two to three times outdoors to assess temporal stability. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST traceable standard lamp, and a simple convolution technique with a Gaussian slit-scattering function to account for the different bandwidths of the instruments, the measured solar irradiance from the spectroradiometers excluding the filter radiometers at 16.5 h UTC had a relative standard deviation of ±4 % for wavelengths greater than 305 nm. The relative standard deviation for the solar irradiance at 16.5 h UTC including the filter radiometer was ±4 % for filter functions above 300 nm. PMID:27446717
Stock, S R; Cole, D C; Tugwell, P; Streiner, D
1996-06-01
Both epidemiologic studies of the factors that contribute to the development of work-related musculoskeletal disorders of the neck and upper limb and intervention studies that test the effectiveness of workplace ergonomic and organizational changes are needed to provide empiric evidence for preventive strategies. This study reviews the relevance and comprehensiveness of existing functional status instruments for epidemiologic studies of work-related neck and upper limb disorders. Twelve domains were identified as the major areas of life affected by workers' neck and upper extremity disorder(s): work, household and family responsibilities, self-care, transportation/driving, sexual activity, sleep, social activities, recreational activities, mood, self-esteem, financial effects, and iatrogenic effects of assessments and treatment. Fifty-two functional status instruments were identified. Of these, 21 met the specified criteria as potentially relevant and were rated on the 3-point scale for relevance and comprehensiveness for each domain. None of the instruments covered all 12 domains adequately.
Vaucher, Paul; Cardoso, Isabel; Veldstra, Janet L.; Herzig, Daniela; Herzog, Michael; Mangin, Patrice; Favrat, Bernard
2014-01-01
When facing age-related cerebral decline, older adults are unequally affected by cognitive impairment without us knowing why. To explore underlying mechanisms and find possible solutions to maintain life-space mobility, there is a need for a standardized behavioral test that relates to behaviors in natural environments. The aim of the project described in this paper was therefore to provide a free, reliable, transparent, computer-based instrument capable of detecting age-related changes on visual processing and cortical functions for the purposes of research into human behavior in computational transportation science. After obtaining content validity, exploring psychometric properties of the developed tasks, we derived (Study 1) the scoring method for measuring cerebral decline on 106 older drivers aged ≥70 years attending a driving refresher course organized by the Swiss Automobile Association to test the instrument's validity against on-road driving performance (106 older drivers). We then validated the derived method on a new sample of 182 drivers (Study 2). We then measured the instrument's reliability having 17 healthy, young volunteers repeat all tests included in the instrument five times (Study 3) and explored the instrument's psychophysical underlying functions on 47 older drivers (Study 4). Finally, we tested the instrument's responsiveness to alcohol and effects on performance on a driving simulator in a randomized, double-blinded, placebo, crossover, dose-response, validation trial including 20 healthy, young volunteers (Study 5). The developed instrument revealed good psychometric properties related to processing speed. It was reliable (ICC = 0.853) and showed reasonable association to driving performance (R2 = 0.053), and responded to blood alcohol concentrations of 0.5 g/L (p = 0.008). Our results suggest that MedDrive is capable of detecting age-related changes that affect processing speed. These changes nevertheless do not necessarily affect driving behavior. PMID:25346674
Linearization of Positional Response Curve of a Fiber-optic Displacement Sensor
NASA Astrophysics Data System (ADS)
Babaev, O. G.; Matyunin, S. A.; Paranin, V. D.
2018-01-01
Currently, the creation of optical measuring instruments and sensors for measuring linear displacement is one of the most relevant problems in the area of instrumentation. Fiber-optic contactless sensors based on the magneto-optical effect are of special interest. They are essentially contactless, non-electrical and have a closed optical channel not subject to contamination. The main problem of this type of sensors is the non-linearity of their positional response curve due to the hyperbolic nature of the magnetic field intensity variation induced by moving the magnetic source mounted on the controlled object relative to the sensing element. This paper discusses an algorithmic method of linearizing the positional response curve of fiber-optic displacement sensors in any selected range of the displacements to be measured. The method is divided into two stages: 1 - definition of the calibration function, 2 - measurement and linearization of the positional response curve (including its temperature stabilization). The algorithm under consideration significantly reduces the number of points of the calibration function, which is essential for the calibration of temperature dependence, due to the use of the points that randomly deviate from the grid points with uniform spacing. Subsequent interpolation of the deviating points and piecewise linear-plane approximation of the calibration function reduces the microcontroller storage capacity for storing the calibration function and the time required to process the measurement results. The paper also presents experimental results of testing real samples of fiber-optic displacement sensors.
Item response theory, computerized adaptive testing, and PROMIS: assessment of physical function.
Fries, James F; Witter, James; Rose, Matthias; Cella, David; Khanna, Dinesh; Morgan-DeWitt, Esi
2014-01-01
Patient-reported outcome (PRO) questionnaires record health information directly from research participants because observers may not accurately represent the patient perspective. Patient-reported Outcomes Measurement Information System (PROMIS) is a US National Institutes of Health cooperative group charged with bringing PRO to a new level of precision and standardization across diseases by item development and use of item response theory (IRT). With IRT methods, improved items are calibrated on an underlying concept to form an item bank for a "domain" such as physical function (PF). The most informative items can be combined to construct efficient "instruments" such as 10-item or 20-item PF static forms. Each item is calibrated on the basis of the probability that a given person will respond at a given level, and the ability of the item to discriminate people from one another. Tailored forms may cover any desired level of the domain being measured. Computerized adaptive testing (CAT) selects the best items to sharpen the estimate of a person's functional ability, based on prior responses to earlier questions. PROMIS item banks have been improved with experience from several thousand items, and are calibrated on over 21,000 respondents. In areas tested to date, PROMIS PF instruments are superior or equal to Health Assessment Questionnaire and Medical Outcome Study Short Form-36 Survey legacy instruments in clarity, translatability, patient importance, reliability, and sensitivity to change. Precise measures, such as PROMIS, efficiently incorporate patient self-report of health into research, potentially reducing research cost by lowering sample size requirements. The advent of routine IRT applications has the potential to transform PRO measurement.
Vaingankar, Janhavi Ajit; Subramaniam, Mythily; Chong, Siow Ann; Abdin, Edimansyah; Orlando Edelen, Maria; Picco, Louisa; Lim, Yee Wei; Phua, Mei Yen; Chua, Boon Yiang; Tee, Joseph Y S; Sherbourne, Cathy
2011-10-31
Instruments to measure mental health and well-being are largely developed and often used within Western populations and this compromises their validity in other cultures. A previous qualitative study in Singapore demonstrated the relevance of spiritual and religious practices to mental health, a dimension currently not included in exiting multi-dimensional measures. The objective of this study was to develop a self-administered measure that covers all key and culturally appropriate domains of mental health, which can be applied to compare levels of mental health across different age, gender and ethnic groups. We present the item reduction and validation of the Positive Mental Health (PMH) instrument in a community-based adult sample in Singapore. Surveys were conducted among adult (21-65 years) residents belonging to Chinese, Malay and Indian ethnicities. Exploratory and confirmatory factor analysis (EFA, CFA) were conducted and items were reduced using item response theory tests (IRT). The final version of the PMH instrument was tested for internal consistency and criterion validity. Items were tested for differential item functioning (DIF) to check if items functioned in the same way across all subgroups. EFA and CFA identified six first-order factor structure (General coping, Personal growth and autonomy, Spirituality, Interpersonal skills, Emotional support, and Global affect) under one higher-order dimension of Positive Mental Health (RMSEA=0.05, CFI=0.96, TLI=0.96). A 47-item self-administered multi-dimensional instrument with a six-point Likert response scale was constructed. The slope estimates and strength of the relation to the theta for all items in each six PMH subscales were high (range:1.39 to 5.69), suggesting good discrimination properties. The threshold estimates for the instrument ranged from -3.45 to 1.61 indicating that the instrument covers entire spectrums for the six dimensions. The instrument demonstrated high internal consistency and had significant and expected correlations with other well-being measures. Results confirmed absence of DIF. The PMH instrument is a reliable and valid instrument that can be used to measure and compare level of mental health across different age, gender and ethnic groups in Singapore.
Increasing Library Effectiveness
ERIC Educational Resources Information Center
Klement, Susan
1977-01-01
Libraries could benefit from the businesslike approach of an entrepreneur. Characteristics of entrepreneurial behavior of value to libraries include: moderate risk-taking as a function of skill, not chance; energetic instrumental activity; insistence upon individual responsibility; knowledge of results of decisions; anticipation of future…
CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review.
Li, Haitao; Liu, Xiaowen; Li, Lin; Mu, Xiaoyi; Genov, Roman; Mason, Andrew J
2016-12-31
Modern biosensors play a critical role in healthcare and have a quickly growing commercial market. Compared to traditional optical-based sensing, electrochemical biosensors are attractive due to superior performance in response time, cost, complexity and potential for miniaturization. To address the shortcomings of traditional benchtop electrochemical instruments, in recent years, many complementary metal oxide semiconductor (CMOS) instrumentation circuits have been reported for electrochemical biosensors. This paper provides a review and analysis of CMOS electrochemical instrumentation circuits. First, important concepts in electrochemical sensing are presented from an instrumentation point of view. Then, electrochemical instrumentation circuits are organized into functional classes, and reported CMOS circuits are reviewed and analyzed to illuminate design options and performance tradeoffs. Finally, recent trends and challenges toward on-CMOS sensor integration that could enable highly miniaturized electrochemical biosensor microsystems are discussed. The information in the paper can guide next generation electrochemical sensor design.
CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review
Li, Haitao; Liu, Xiaowen; Li, Lin; Mu, Xiaoyi; Genov, Roman; Mason, Andrew J.
2016-01-01
Modern biosensors play a critical role in healthcare and have a quickly growing commercial market. Compared to traditional optical-based sensing, electrochemical biosensors are attractive due to superior performance in response time, cost, complexity and potential for miniaturization. To address the shortcomings of traditional benchtop electrochemical instruments, in recent years, many complementary metal oxide semiconductor (CMOS) instrumentation circuits have been reported for electrochemical biosensors. This paper provides a review and analysis of CMOS electrochemical instrumentation circuits. First, important concepts in electrochemical sensing are presented from an instrumentation point of view. Then, electrochemical instrumentation circuits are organized into functional classes, and reported CMOS circuits are reviewed and analyzed to illuminate design options and performance tradeoffs. Finally, recent trends and challenges toward on-CMOS sensor integration that could enable highly miniaturized electrochemical biosensor microsystems are discussed. The information in the paper can guide next generation electrochemical sensor design. PMID:28042860
Method and apparatus for measuring response time
Johanson, Edward W.; August, Charles
1985-01-01
A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.
Method and apparatus for measuring response time
Johanson, E.W.; August, C.
1983-08-11
A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.
Andrew, Emily; Nehme, Ziad; Bernard, Stephen; Smith, Karen
2016-10-01
Although a number of validated health-related quality of life (HR-QOL) instruments exist for critical care populations, a standardised approach to assessing the HR-QOL of out-of-hospital cardiac arrest (OHCA) survivors has not been developed. We sought to compare the responses of 12-month OHCA survivors to three HR-QOL and functional recovery instruments, and assess instrument validity. The Victorian Ambulance Cardiac Arrest Registry invited 12-month OHCA survivors to participate in telephone follow-up between January 2011 and December 2015. Responders provided answers to the 12 Item Short Form Health Survey (SF-12), Three-Level EuroQol-5D (EQ-5D-3L) and the Glasgow Outcome Scale-Extended (GOSE). The SF-12 was also used to derive the SF-6D. Responses were used to assess the interpretability and construct validity of the instruments. A total of 1188 patients and proxies responded. Large ceiling effects were observed for the EQ-5D-3L (patients=46%, proxies=23%). Substantial variability was also observed in SF-6D responses for patients who reported full health according to the EQ-5D-3L. For patient responders, the strongest correlations were observed between the EQ-5D-3L index score and SF-6D (ρ=0.65, p<0.001), and between the SF-6D and SF-12 physical component (ρ=0.69, p<0.001). The distribution of the SF-6D and EQ-5D-3L differed significantly for patients reporting a lower or upper moderate GOSE outcome and lower or upper good recovery (p<0.001 for all comparisons). The EQ-5D-3L demonstrated limited interpretability due to the presence of ceiling effects. However, the measurement properties of the SF-12, SF-6D and GOSE suggest that these may be useful measures of HR-QOL and functional recovery in OHCA survivors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Physiological responses to environmental factors related to space flight
NASA Technical Reports Server (NTRS)
Pace, N.; Grunbaum, B. W.; Kodama, A. M.; Mains, R. C.; Rahlmann, D. F.
1975-01-01
Physiological procedures and instrumentation developed for the measurement of hemodynamic and metabolic parameters during prolonged periods of weightlessness are described along with the physiological response of monkeys to weightlessness. Specific areas examined include: cardiovascular studies; thyroid function; blood oxygen transport; growth and reproduction; excreta analysis for metabolic balance studies; and electrophoretic separation of creatine phosphokinase isoenzymes in human blood.
INTERPRETING PHYSICAL AND BEHAVIORAL HEALTH SCORES FROM NEW WORK DISABILITY INSTRUMENTS
Marfeo, Elizabeth E.; Ni, Pengsheng; Chan, Leighton; Rasch, Elizabeth K.; McDonough, Christine M.; Brandt, Diane E.; Bogusz, Kara; Jette, Alan M.
2015-01-01
Objective To develop a system to guide interpretation of scores generated from 2 new instruments measuring work-related physical and behavioral health functioning (Work Disability – Physical Function (WD-PF) and WD – Behavioral Function (WD-BH)). Design Cross-sectional, secondary data from 3 independent samples to develop and validate the functional levels for physical and behavioral health functioning. Subjects Physical group: 999 general adult subjects, 1,017 disability applicants and 497 work-disabled subjects. Behavioral health group: 1,000 general adult subjects, 1,015 disability applicants and 476 work-disabled subjects. Methods Three-phase analytic approach including item mapping, a modified-Delphi technique, and known-groups validation analysis were used to develop and validate cut-points for functional levels within each of the WD-PF and WD-BH instrument’s scales. Results Four and 5 functional levels were developed for each of the scales in the WD-PF and WD-BH instruments. Distribution of the comparative samples was in the expected direction: the general adult samples consistently demonstrated scores at higher functional levels compared with the claimant and work-disabled samples. Conclusion Using an item-response theory-based methodology paired with a qualitative process appears to be a feasible and valid approach for translating the WD-BH and WD-PF scores into meaningful levels useful for interpreting a person’s work-related physical and behavioral health functioning. PMID:25729901
Updates in the IR responsivity of VIR, the spectrometer of the Dawn mission.
NASA Astrophysics Data System (ADS)
Ammannito, Eleonora; Mc Cord, Thomas B.; De Sanctis, Maria Cristina.; Combe, Jean-Philippe
VIR-MS (Visual and Infrared Mapping Spectrometer) is the imaging spectrometer of the Dawn mission (1,2). Here, first we describe the computation of a new instrument responsivity based on the internal calibration data acquired during the operations at Vesta, and then we describe its effect on the dataset and on the results published so far. VIR-MS was built in Italy by a scientific-industrial (IAPS/INAF in Rome (Italy) and Selex ES in Campi Bisenzio (Fi, Italy)) consortium financially supported by the Italian Space Agency. VIR-MS is an high spatial resolution spectrometer (FOV of 64mrad, IFOV of 250 µrad) in the 0.25-5 µm range with an IFOV of 250 µrad and a spectral sampling of about 2 nm in the visible range and 10 nm in the IR range. The results of the on-ground calibration held in the Selex calibration facility in September 2005 were already presented and discussed in a paper (2). This version has been used to calibrate the data available on the Planetary Data System (PDS) Small Bodies Node, dataset used in all the papers published so far. However, after the operations at the asteroid Vesta, we have identified some artifacts in the instrument responsivity in the 2.5-3.5 µm region, which is where several absorption bands of OH and H2O occur. Those artifacts were systematic, and therefore they did not prevent the detection of relative spectral variations associated to OH and H2O. Actually, the only paper published in which are discussed spectra in this range (3) used a different calibration method described in the paper itself. This method used a simple correction of the response function based on an empirical calibration correction that is appropriate to recover the signal in that specific range. However, the absolute absorption band depth of OH and H2O could not be calculated. To compute a new instrument responsivity we used the internal lamp of the spectrometer. This lamp, made of a tungsten filament, is characterized by a blackbody-like emission at about 2400K (4). Since the spectrum of the infrared radiation emitted by the tungsten filaments is featureless, a polystyrene filter was inserted for a wavelength calibration of the IR channel. The idea was to use the black body radiation of this lamp to retrieve a relative Instrument Responsivity in the 2.5-3.5 µm region. First we calibrated the signal from internal calibration lamp with the on-ground responsivity, and then we retrieved the equivalent temperature of the radiation fitting a Planck curve. The next step was to compute the Planck function at the equivalent temperature. The new Instrument Responsivity is the result of the ratio between the raw signal of the lamp and the Planck function. This ratio must be multiplied by a factor to take into account the integration time used to acquire the signal, the transmittance of the polystyrene filter, and the viewing geometry. The new instrument responsivity function minimizes most calibration residuals that was showing as artifact peaks between 2.5 and 2.9 µm in the previous calibration. It now allows the use of VIR spectra to identify absorption bands of OH and H2O, without requiring additional empirical corrections. As calibration is always an on-going process, we are looking forward to enable the interpretation of absolute absorption band depths, which is a required step for the calculation of surface material abundances. References: (1) C.T. Russell & C.A. Raymond, Space Sci. Rev., 163, 3 2011 (2) M.C. De Sanctis, A. Coradini, E. Ammannito, E., et al. Space Sci. Rev.,163, 329, 2011 (3) M.C. DeSanctis, J-Ph. Combe et al APJL 758:L36, 2013 (4)R. Melchiorri, G. Piccioni, A. Mazzoni, Rev. Sci. Instrum. 74(8), 3796-3801 2003
Robots in food systems: a review and assessment of potential uses.
Adams, E A; Messersmith, A M
1986-04-01
Management personnel in foodservice, food processing, and robot industries were surveyed to evaluate potential job functions for robots in the food industry. The survey instrument listed 64 different food-related job functions that participants were asked to assess as appropriate or not appropriate for robotic implementation. Demographic data were collected from each participant to determine any positive or negative influence on job function responses. The survey responses were statistically evaluated using frequencies and the chi-square test of significance. Sixteen of the 64 job functions were identified as appropriate for robot implementation in food industries by both robot manufacturing and food managers. The study indicated, first, that food managers lack knowledge about robots and robot manufacturing managers lack knowledge about food industries. Second, robots are not currently being used to any extent in the food industry. Third, analysis of the demographic data in relation to the 16 identified job functions showed no significant differences in responses.
44 CFR 351.11 - Functions of committees.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., training, emergency instrumentation, transportation, information, education and Federal response. The FRPCC... observe exercises to evaluate adequacy of the plans. Each Federal agency member of the RACs will support....11 Section 351.11 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT...
Virtual Instrumentation for a Fiber-Optics-Based Artificial Nerve
NASA Technical Reports Server (NTRS)
Lyons, Donald R.; Kyaw, Thet Mon; Griffin, DeVon (Technical Monitor)
2001-01-01
A LabView-based computer interface for fiber-optic artificial nerves has been devised as a Masters thesis project. This project involves the use of outputs from wavelength multiplexed optical fiber sensors (artificial nerves), which are capable of producing dense optical data outputs for physical measurements. The potential advantages of using optical fiber sensors for sensory function restoration is the fact that well defined WDM-modulated signals can be transmitted to and from the sensing region allowing networked units to replace low-level nerve functions for persons desirous of "intelligent artificial limbs." Various FO sensors can be designed with high sensitivity and the ability to be interfaced with a wide range of devices including miniature shielded electrical conversion units. Our Virtual Instrument (VI) interface software package was developed using LabView's "Laboratory Virtual Instrument Engineering Workbench" package. The virtual instrument has been configured to arrange and encode the data to develop an intelligent response in the form of encoded digitized signal outputs. The architectural layout of our nervous system is such that different touch stimuli from different artificial fiber-optic nerve points correspond to gratings of a distinct resonant wavelength and physical location along the optical fiber. Thus, when an automated, tunable diode laser sends scans, the wavelength spectrum of the artificial nerve, it triggers responses that are encoded with different touch stimuli by way wavelength shifts in the reflected Bragg resonances. The reflected light is detected and a resulting analog signal is fed into ADC1 board and DAQ card. Finally, the software has been written such that the experimenter is able to set the response range during data acquisition.
NASA Astrophysics Data System (ADS)
Sauvé, Alexandre; Montier, Ludovic
2016-12-01
Context: Bolometers are high sensitivity detector commonly used in Infrared astronomy. The HFI instrument of the Planck satellite makes extensive use of them, but after the satellite launch two electronic related problems revealed critical. First an unexpected excess response of detectors at low optical excitation frequency for ν < 1 Hz, and secondly the Analog To digital Converter (ADC) component had been insufficiently characterized on-ground. These two problems require an exquisite knowledge of detector response. However bolometers have highly nonlinear characteristics, coming from their electrical and thermal coupling making them very difficult to model. Goal: We present a method to build the analytical transfer function in frequency domain which describe the voltage response of an Alternative Current (AC) biased bolometer to optical excitation, based on the standard bolometer model. This model is built using the setup of the Planck/HFI instrument and offers the major improvement of being based on a physical model rather than the currently in use had-hoc model based on Direct Current (DC) bolometer theory. Method: The analytical transfer function expression will be presented in matrix form. For this purpose, we build linearized versions of the bolometer electro thermal equilibrium. A custom description of signals in frequency is used to solve the problem with linear algebra. The model performances is validated using time domain simulations. Results: The provided expression is suitable for calibration and data processing. It can also be used to provide constraints for fitting optical transfer function using real data from steady state electronic response and optical response. The accurate description of electronic response can also be used to improve the ADC nonlinearity correction for quickly varying optical signals.
The Sandia transportable triggered lightning instrumentation facility
NASA Technical Reports Server (NTRS)
Schnetzer, George H.; Fisher, Richard J.
1991-01-01
Development of the Sandia Transportable Triggered Lightning Instrumentation Facility (SATTLIF) was motivated by a requirement for the in situ testing of a munitions storage bunker. Transfer functions relating the incident flash currents to voltages, currents, and electromagnetic field values throughout the structure will be obtained for use in refining and validating a lightning response computer model of this type of structure. A preliminary shakedown trial of the facility under actual operational conditions was performed during summer of 1990 at the Kennedy Space Center's (KSC) rocket-triggered lightning test site. A description is given of the SATTLIF, which is readily transportable on a single flatbed truck of by aircraft, and its instrumentation for measuring incident lightning channel currents and the responses of the systems under test. Measurements of return-stroke current peaks obtained with the SATTLIF are presented. Agreement with data acquired on the same flashes with existing KSC instrumentation is, on average, to within approximately 7 percent. Continuing currents were measured with a resolution of approximately 2.5 A. This field trial demonstrated the practicality of using a transportable triggered lightning facility for specialized test applications.
Tadić, Valerija; Cooper, Andrew; Cumberland, Phillippa; Lewando-Hundt, Gillian; Rahi, Jugnoo S
2016-01-01
To report piloting and initial validation of the VQoL_CYP, a novel age-appropriate vision-related quality of life (VQoL) instrument for self-reporting by children with visual impairment (VI). Participants were a random patient sample of children with VI aged 10-15 years. 69 patients, drawn from patient databases at Great Ormond Street Hospital and Moorfields Eye Hospital, United Kingdom, participated in piloting of the draft 47-item VQoL instrument, which enabled preliminary item reduction. Subsequent administration of the instrument, alongside functional vision (FV) and generic health-related quality of life (HRQoL) self-report measures, to 101 children with VI comprising a nationally representative sample enabled further item reduction and evaluation of psychometric properties using Rasch analysis. Construct validity was assessed through Pearson correlation coefficients. Item reduction through piloting (8 items removed for skewness and individual item response pattern) and validation (1 item removed for skewness and 3 for misfit in Rasch) produced a 35-item scale, with fit values within acceptable limits, no notable differential item functioning, good measurement precision, ordered response categories and acceptable targeting in Rasch. The VQoL_CYP showed good construct validity, correlating strongly with HRQoL scores, moderately with FV scores but not with acuity. Robust child-appropriate self-report VQoL measures for children with VI are necessary for understanding the broader impacts of living with a visual disability, distinguishing these from limited functioning per se. Future planned use in larger patient samples will allow further psychometric development of the VQoL_CYP as an adjunct to objective outcomes assessment.
Sadiqi, Said; Lehr, A Mechteld; Post, Marcel W; Jacobs, Wilco C H; Aarabi, Bizhan; Chapman, Jens R; Dunn, Robert N; Dvorak, Marcel F; Fehlings, Michael G; Rajasekaran, S; Vialle, Luiz R; Vaccaro, Alexander R; Oner, F Cumhur
2016-08-01
There is no outcome instrument specifically designed and validated for spine trauma patients without complete paralysis, which makes it difficult to compare outcomes of different treatments of the spinal column injury within and between studies. The paper aimed to report on the evidence-based consensus process that resulted in the selection of core International Classification of Functioning, Disability, and Health (ICF) categories, as well as the response scale for use in a universal patient-reported outcome measure for patients with traumatic spinal column injury. The study used a formal decision-making and consensus process. The sample includes patients with a primary diagnosis of traumatic spinal column injury, excluding completely paralyzed and polytrauma patients. The wide array of function and health status of patients with traumatic spinal column injury was explored through the identification of all potentially meaningful ICF categories. A formal decision-making and consensus process integrated evidence from four preparatory studies. Three studies aimed to identify relevant ICF categories from three different perspectives. The research perspective was covered by a systematic literature review identifying outcome measures focusing on the functioning and health of spine trauma patients. The expert perspective was explored through an international web-based survey among spine surgeons from the five AOSpine International world regions. The patient perspective was investigated in an international empirical study. A fourth study investigated various response scales for their potential use in the future universal outcome instrument. This work was supported by AOSpine. AOSpine is a clinical division of the AO Foundation, an independent medically guided non-profit organization. The AOSpine Knowledge Forums are pathology-focused working groups acting on behalf of AOSpine in their domain of scientific expertise. Combining the results of the preparatory studies, the list of ICF categories presented at the consensus conference included 159 different ICF categories. Based on voting and discussion, 11 experts from 6 countries selected a total of 25 ICF categories as core categories for patient-reported outcome measurement in adult traumatic spinal column injury patients (9 body functions, 14 activities and participation, and 2 environmental factors). The experts also agreed to use the Numeric Rating Scale 0-100 as response scale in the future universal outcome instrument. A formal consensus process integrating evidence and expert opinion led to a set of 25 core ICF categories for patient-reported outcome measurement in adult traumatic spinal column injury patients, as well as the response scale for use in the future universal disease-specific outcome instrument. The adopted core ICF categories could also serve as a benchmark for assessing the content validity of existing and future outcome instruments used in this specific patient population. Copyright © 2016 Elsevier Inc. All rights reserved.
Unravelling Responses for the Canadian National Seismic Network
NASA Astrophysics Data System (ADS)
Mulder, T. L.
2009-12-01
There are a number of attendant difficulties any network must deal with that range from defining the transfer function to instrument naming conventions to choices of final local file format representation. These choices ultimately result in the ease of conversion to other data formats and therefore directly impact useability. In particular, the ease of data exhange and use of established software that is dependent on standard data types is impacted. This becomes particularly critical with large (terabyte) dataset processing and when integrating external datasets into analysis procedures. Transfer functions, often referred to as instrument responses, are a key component in describing instrumentation. The transfer function describes the complete response of the seismic system. The seismic system is designed to be a linear system that can be decomposed into discrete components. Analogue or digital convolution can be represented as multiplication in the frequency domain. The two basic elements of a seismic system are the sensor and datalogger. The analogue sensor can be represented mathmatically as poles and zeroes. The datalogger can be further broken down into its discrete analogue and digital components: the preamp, A/D converter, and fir filters. The Canadian seismic network (CNSN) digitizers have an additional complication. To save telemetry band-width, the 32 bit signal from the digitizer has a transmission gain removed. The transmission gain (txgain) represents the number of the least significant bits truncated from the sample (2^txgain) after which the data is compressed and transmitted. While telemetry band-width is not the issue it was, now that many sites have ip connectivity, this user programmable transmission gain is still in use and can vary from station to station. The processes receiving the transmitted data do not restore the pre-transmission scaling, consequently the archived waveform files can vary in bit weight over time from station to station depending on the value of the transmission gain. Consequently the transmission gain must be factored into the transfer function. This presentation describes the process for generating the transfer function based on the constituent components discussed here. A matlab routine run on the database generates the transfer function plots for the network.
Bost, James E; Williams, Brian A; Bottegal, Matthew T; Dang, Qianyu; Rubio, Doris M
2007-12-01
We evaluated the validity and responsiveness of three instruments: the numeric rating scale (NRS) pain score, the 8-item Short-Form Health Survey (SF-8), and the 40-item Quality of Recovery from Anesthesia (QoR) Survey in 154 outpatients undergoing anterior cruciate ligament reconstruction (ACLR). The objective was to provide a robust psychometric basis for outcome survey selection for surgical outpatients undergoing regional anesthesia without general anesthesia. Patients undergoing ACLR with a standardized spinal anesthesia plan were randomized to receive a perineural catheter with either placebo injection-infusion, or injection-infusion with levobupivacaine. Patients completed the NRS, SF-8, and QoR instruments for four postoperative days to evaluate pain, physical function, and mental function. Regarding pain, neither the NRS nor the QoR offered advantages over the SF-8. Regarding physical function, the QoR physical independence composite offered no advantage over the SF-8 physical component summary. The QoR physical comfort composite assessed short-term changes in treatment-related side effects, and thus provided information not covered by the SF-8. Regarding mental function, the SF-8 mental component summary and QoR emotional state composite showed little change over the four days, although the latter measure showed higher responsiveness to change. For ACLR outpatients receiving regional anesthesia, the SF-8 is sufficient to assess postoperative pain and physical function. Adding the QoR physical comfort composite will help assess short-term side effects.
NASA Technical Reports Server (NTRS)
Zeller, Mary V.; Lei, Jih-Fen
2002-01-01
The Instrumentation and Controls Division is responsible for planning, conducting and directing basic and applied research on advanced instrumentation and controls technologies for aerospace propulsion and power applications. The Division's advanced research in harsh environment sensors, high temperature high power electronics, MEMS (microelectromechanical systems), nanotechnology, high data rate optical instrumentation, active and intelligent controls, and health monitoring and management will enable self-feeling, self-thinking, self-reconfiguring and self-healing Aerospace Propulsion Systems. These research areas address Agency challenges to deliver aerospace systems with reduced size and weight, and increased functionality and intelligence for future NASA missions in advanced aeronautics, economical space transportation, and pioneering space exploration. The Division also actively supports educational and technology transfer activities aimed at benefiting all humankind.
Instrumenting Beliefs in Threshold Public Goods
2016-01-01
Understanding the causal impact of beliefs on contributions in Threshold Public Goods (TPGs) is particularly important since the social optimum can be supported as a Nash Equilibrium and best-response contributions are a function of beliefs. Unfortunately, investigations of the impact of beliefs on behavior are plagued with endogeneity concerns. We create a set of instruments by cleanly and exogenously manipulating beliefs without deception. Tests indicate that the instruments are valid and relevant. Perhaps surprisingly, we fail to find evidence that beliefs are endogenous in either the one-shot or repeated-decision settings. TPG allocations are determined by a base contribution and beliefs in a one shot-setting. In the repeated-decision environment, once we instrument for first-round allocations, we find that second-round allocations are driven equally by beliefs and history. Moreover, we find that failing to instrument prior decisions overstates their importance. PMID:26859492
Health- and vision-related quality of life in intellectually disabled children.
Cui, Yu; Stapleton, Fiona; Suttle, Catherine; Bundy, Anita
2010-01-01
To investigate the psychometric properties of instruments for the assessment of self-reported functional vision performance and health-related quality of life in children with intellectual disabilities (IDs). Two instruments [Autoquestionnaire Enfant Image (AUQUEI), LV Prasad-Functional Vision Questionnaire (LVP-FVQ)] designed for the assessment of functional vision and health-related quality of life were adapted and administered to 168 school children with ID, aged 8 to 18 years. Rasch analysis was used to determine the appropriateness of the rating scales of these instruments and to identify any redundant items. Redundant items were excluded based on descriptive statistics and Rasch analysis, leaving 17 of 23 items in the revised AUQUEI and 16 of 22 in the LVP-FVQ. The AUQUEI items showed disordered thresholds on the rating scale. A modified step calibration (collapsed from four categories to three categories) resulted in ordered response thresholds for all items. The adjusted instrument produced an overall fit to the model (mean item infit = 1.06, SD = 0.32; mean item outfit = 1.11, SD = 0.35), indicating good construct validity. After Rasch analysis, the AUQUEI showed good content validity (person separation = 2.18; item reliability = 0.99; Cronbach alpha = 0.89). Increased similarity of person and item means and SDs on the logit scale after modification would indicate that the instrument was more applicable to the target population in its modified form. In contrast, the LVP-FVQ had a low person separation (1.35), suggesting that a more appropriate instrument is needed for assessment of vision-related quality of life in children with ID. The psychometric properties of two instruments were explored using Rasch analysis. By rescaling and reduction of items, the instruments were modified for use in a population of children with at least mild to moderate ID. However, an alternative instrument is needed for the assessment of vision-related quality of life in intellectually disabled children with normal vision or mild visual abnormalities.
White, Isabella D; Sangha, Amrit; Lucas, Grace; Wiseman, Theresa
2016-12-01
Practitioners and researchers require an outcome measure that accurately identifies the range of common treatment-induced changes in sexual function and well-being experienced by women after cervical or endometrial cancer. This systematic review critically appraised the measurement properties and clinical utility of instruments validated for the measurement of female sexual dysfunction (FSD) in this clinical population. A bibliographic database search for questionnaire development or validation papers was completed and methodological quality and measurement properties of selected studies rated using the Consensus-based Standards for the selection of health Measurement Instrument (COSMIN) checklist. 738 articles were screened, 13 articles retrieved for full text assessment and 7 studies excluded, resulting in evaluation of 6 papers; 2 QoL and 4 female sexual morbidity measures. Five of the six instruments omitted one or more dimension of female sexual function and only one instrument explicitly measured distress associated with sexual changes as per DSM V (APA 2013) diagnostic criteria. None of the papers reported measurement error, responsiveness data was available for only two instruments, three papers failed to report on criterion validity, and test-retest reliability reporting was inconsistent. Heterosexual penile-vaginal intercourse remains the dominant sexual activity focus for sexual morbidity PROMS terminology and instruments lack explicit reference to solo or non-coital sexual expression or validation in a non-heterosexual sample. Four out of six instruments included mediating treatment or illness items such as vaginal changes, menopause or altered body image. Findings suggest that the Female Sexual Function Index (FSFI) remains the most robust sexual morbidity outcome measure, for research or clinical use, in sexually active women treated for cervical or endometrial cancer. Development of an instrument that measures sexual dysfunction in women who are infrequently/not sexually active due to treatment consequences is still required to identify women in need of sexual rehabilitation. Copyright © 2016 Elsevier Inc. All rights reserved.
2012-11-01
Experimental Physics Laboratory, Kavli Institute for Particle Astrophysics and Cosmology , Department of Physics and SLAC National Accelerator...Laboratory, Stanford University, Stanford, CA 94305, USA; echarles@slac.stanford.edu 3 Department of Physics, Center for Cosmology and Astro-Particle Physics
The development of antisocial behavior: what can we learn from functional neuroimaging studies?
Crowe, S L; Blair, R J R
2008-01-01
The recent development of low-risk imaging technologies, such as functional magnetic resonance imaging (fMRI), have had a significant impact on the investigation of psychopathologies in children and adolescents. This review considers what we can infer from fMRI work regarding the development of conduct disorder (CD) and oppositional defiant disorder (ODD). We make two central assumptions that are grounded in the empirical literature. First, the diagnoses of CD and ODD identify individuals with heterogeneous pathologies; that is, different developmental pathologies can receive a CDD or ODD diagnosis. This is indicated by the comorbidities associated with CD/ODD, some of which appear to be mutually exclusive at the biological level (e.g., posttraumatic stress disorder [PTSD] and psychopathic tendencies). Second, two populations of antisocial individuals can be identified: those that show an increased risk for only reactive aggression and those that show an increased risk for both reactive and instrumental aggression. We review the fMRI data indicating that particular comorbidities of CD/ODD (i.e., mood and anxiety conditions such as childhood bipolar disorder and PTSD) are associated with either increased responsiveness of neural regions implicated in the basic response to threat (e.g., the amygdala) or decreased responsiveness in regions of frontal cortex (e.g., ventromedial frontal cortex) that are implicated in the regulation of the basic threat response. We suggest why such pathology would increase the risk for reactive aggression and, in turn, lead to the association with a CD/ODD diagnosis. We also review the literature on psychopathic tendencies, a condition where the individual is at significantly elevated risk for both reactive and instrumental aggression. We show that in individuals with psychopathic tendencies, the functioning of the amygdala in stimulus-reinforcement learning and of the ventromedial frontal cortex in the representation of reinforcement expectancies is impaired. We suggest why such pathology would increase the risk for reactive and instrumental aggression and thus also lead to the association with a CD/ODD diagnosis.
Cheng, Su-Fen; Lee-Hsieh, Jane; Turton, Michael A; Lin, Kuan-Chia
2014-06-01
Little research has investigated the establishment of norms for nursing students' self-directed learning (SDL) ability, recognized as an important capability for professional nurses. An item response theory (IRT) approach was used to establish norms for SDL abilities valid for the different nursing programs in Taiwan. The purposes of this study were (a) to use IRT with a graded response model to reexamine the SDL instrument, or the SDLI, originally developed by this research team using confirmatory factor analysis and (b) to establish SDL ability norms for the four different nursing education programs in Taiwan. Stratified random sampling with probability proportional to size was used. A minimum of 15% of students from the four different nursing education degree programs across Taiwan was selected. A total of 7,879 nursing students from 13 schools were recruited. The research instrument was the 20-item SDLI developed by Cheng, Kuo, Lin, and Lee-Hsieh (2010). IRT with the graded response model was used with a two-parameter logistic model (discrimination and difficulty) for the data analysis, calculated using MULTILOG. Norms were established using percentile rank. Analysis of item information and test information functions revealed that 18 items exhibited very high discrimination and two items had high discrimination. The test information function was higher in this range of scores, indicating greater precision in the estimate of nursing student SDL. Reliability fell between .80 and .94 for each domain and the SDLI as a whole. The total information function shows that the SDLI is appropriate for all nursing students, except for the top 2.5%. SDL ability norms were established for each nursing education program and for the nation as a whole. IRT is shown to be a potent and useful methodology for scale evaluation. The norms for SDL established in this research will provide practical standards for nursing educators and students in Taiwan.
On-ground calibration of the BEPICOLOMBO/SIMBIO-SYS at instrument level
NASA Astrophysics Data System (ADS)
Rodriguez-Ferreira, J.; Poulet, F.; Eng, P.; Longval, Y.; Dassas, K.; Arondel, A.; Langevin, Y.; Capaccioni, F.; Filacchione, G.; Palumbo, P.; Cremonese, G.; Dami, M.
2012-04-01
The Mercury Planetary Orbiter/BepiColombo carries an integrated suite of instruments, the Spectrometer and Imagers for MPO BepiColombo-Integrated Observatory SYStem (SIMBIO-SYS). SIMBIO-SYS has 3 channels: a stereo imaging system (STC), a high-resolution imager (HRIC) and a visible-near-infrared imaging spectrometer (VIHI). SIMBIO-SYS will scan the surface of Mercury with these three channels and determine the physical, morphological and compositional properties of the entire planet. Before integration on the S/C, an on-ground calibration at the channels and at the instrument levels will be performed so as to describe the instrumental responses as a function of various parameters that might evolve while the instruments will be operating [1]. The Institut d'Astrophysique Spatiale (IAS) is responsible for the on-ground instrument calibration at the instrument level. During the 4 weeks of calibration campaign planned for June 2012, the instrument will be maintained in a mechanical and thermal environment simulating the space conditions. Four Optical stimuli (QTH lamp, Integrating Sphere, BlackBody with variable temperature from 50 to 1200°C and Monochromator), are placed over an optical bench to illuminate the four channels so as to make the radiometric calibration, straylight monitoring, as well as spectral proofing based on laboratory mineral samples. The instrument will be mounted on a hexapod placed inside a thermal vacuum chamber during the calibration campaign. The hexapod will move the channels within the well-characterized incoming beam. We will present the key activities of the preparation of this calibration: the derivation of the instrument radiometric model, the implementation of the optical, mechanical and software interfaces of the calibration assembly, the characterization of the optical bench and the definition of the calibration procedures.
Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley
2012-08-01
Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than another when applied to subjects with knee OA. We believe that all 3 instruments are appropriate outcome measures to examine change in functional status of patients with knee OA.
NASA Technical Reports Server (NTRS)
Daniels, Janet L.; Smith, G. Louis; Priestley, Kory J.; Thomas, Susan
2014-01-01
The validation of in-orbit instrument performance requires stability in both instrument and calibration source. This paper describes a method of validation using lunar observations scanning near full moon by the Clouds and Earth Radiant Energy System (CERES) instruments. Unlike internal calibrations, the Moon offers an external source whose signal variance is predictable and non-degrading. From 2006 to present, in-orbit observations have become standardized and compiled for the Flight Models-1 and -2 aboard the Terra satellite, for Flight Models-3 and -4 aboard the Aqua satellite, and beginning 2012, for Flight Model-5 aboard Suomi-NPP. Instrument performance parameters which can be gleaned are detector gain, pointing accuracy and static detector point response function validation. Lunar observations are used to examine the stability of all three detectors on each of these instruments from 2006 to present. This validation method has yielded results showing trends per CERES data channel of 1.2% per decade or less.
Techniques for active passivation
Roscioli, Joseph R.; Herndon, Scott C.; Nelson, Jr., David D.
2016-12-20
In one embodiment, active (continuous or intermittent) passivation may be employed to prevent interaction of sticky molecules with interfaces inside of an instrument (e.g., an infrared absorption spectrometer) and thereby improve response time. A passivation species may be continuously or intermittently applied to an inlet of the instrument while a sample gas stream is being applied. The passivation species may have a highly polar functional group that strongly binds to either water or polar groups of the interfaces, and once bound presents a non-polar group to the gas phase in order to prevent further binding of polar molecules. The instrument may be actively used to detect the sticky molecules while the passivation species is being applied.
Buck, Harleah G; Harkness, Karen; Ali, Muhammad Usman; Carroll, Sandra L; Kryworuchko, Jennifer; McGillion, Michael
2017-04-01
Caregivers (CGs) contribute important assistance with heart failure (HF) self-care, including daily maintenance, symptom monitoring, and management. Until CGs' contributions to self-care can be quantified, it is impossible to characterize it, account for its impact on patient outcomes, or perform meaningful cost analyses. The purpose of this study was to conduct psychometric testing and item reduction on the recently developed 34-item Caregiver Contribution to Heart Failure Self-care (CACHS) instrument using classical and item response theory methods. Fifty CGs (mean age 63 years ±12.84; 70% female) recruited from a HF clinic completed the CACHS in 2014 and results evaluated using classical test theory and item response theory. Items would be deleted for low (<.05) or high (>.95) endorsement, low (<.3) or high (>.7) corrected item-total correlations, significant pairwise correlation coefficients, floor or ceiling effects, relatively low latent trait and item information function levels (<1.5 and p > .5), and differential item functioning. After analysis, 14 items were excluded, resulting in a 20-item instrument (self-care maintenance eight items; monitoring seven items; and management five items). Most items demonstrated moderate to high discrimination (median 2.13, minimum .77, maximum 5.05), and appropriate item difficulty (-2.7 to 1.4). Internal consistency reliability was excellent (Cronbach α = .94, average inter-item correlation = .41) with no ceiling effects. The newly developed 20-item version of the CACHS is supported by rigorous instrument development and represents a novel instrument to measure CGs' contribution to HF self-care. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Tam, James; Ahmad, Imad A Haidar; Blasko, Andrei
2018-06-05
A four parameter optimization of a stability indicating method for non-chromophoric degradation products of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), 1-stearoyl-sn-glycero-3-phosphocholine and 2-stearoyl-sn-glycero-3-phosphocholine was achieved using a reverse phase liquid chromatography-charged aerosol detection (RPLC-CAD) technique. Using the hydrophobic subtraction model of selectivity, a core-shell, polar embedded RPLC column was selected followed by gradient-temperature optimization, resulting in ideal relative peak placements for a robust, stability indicating separation. The CAD instrument parameters, power function value (PFV) and evaporator temperature were optimized for lysophosphatidylcholines to give UV absorbance detector-like linearity performance within a defined concentration range. The two lysophosphatidylcholines gave the same response factor in the selected conditions. System specific power function values needed to be set for the two RPLC-CAD instruments used. A custom flow-divert profile, sending only a portion of the column effluent to the detector, was necessary to mitigate detector response drifting effects. The importance of the PFV optimization for each instrument of identical build and how to overcome recovery issues brought on by the matrix effects from the lipid-RP stationary phase interaction is reported. Copyright © 2018 Elsevier B.V. All rights reserved.
Peña-Haro, Salvador; García-Prats, Alberto; Pulido-Velazquez, Manuel
2014-11-15
Economic instruments can be used to control groundwater nitrate pollution due to the intensive use of fertilizers in agriculture. In order to test their efficiency on the reduction of nitrate leaching, we propose an approach based on the combined use of production and pollution functions to derive the impacts on the expected farmer response of these instruments. Some of the most important factors influencing nitrate leaching and crop yield are the type of soil and the climatic conditions. Crop yield and nitrate leaching responses to different soil and climatic conditions were classified by means of a cluster analysis, and crops located in different areas but with similar response were grouped for the analysis. We use a spatial economic optimization model to evaluate the potential of taxes on nitrogen fertilizers, water prices, and taxes on nitrate emissions to reduce nitrate pollution, as well as their economic impact in terms of social welfare and farmers' net benefits. The method was applied to the Mancha Oriental System (MOS) in Spain, a large area with different soil types and climatic conditions. We divided the study area into zones of homogeneous crop production and nitrate leaching properties. Results show spatially different responses of crop growth and nitrate leaching, proving how the cost-effectiveness of pollution control instruments is contingent upon the spatial heterogeneities of the problem. Copyright © 2014 Elsevier B.V. All rights reserved.
Using item response theory to address vulnerabilities in FFQ.
Kazman, Josh B; Scott, Jonathan M; Deuster, Patricia A
2017-09-01
The limitations for self-reporting of dietary patterns are widely recognised as a major vulnerability of FFQ and the dietary screeners/scales derived from FFQ. Such instruments can yield inconsistent results to produce questionable interpretations. The present article discusses the value of psychometric approaches and standards in addressing these drawbacks for instruments used to estimate dietary habits and nutrient intake. We argue that a FFQ or screener that treats diet as a 'latent construct' can be optimised for both internal consistency and the value of the research results. Latent constructs, a foundation for item response theory (IRT)-based scales (e.g. Patient Reported Outcomes Measurement Information System) are typically introduced in the design stage of an instrument to elicit critical factors that cannot be observed or measured directly. We propose an iterative approach that uses such modelling to refine FFQ and similar instruments. To that end, we illustrate the benefits of psychometric modelling by using items and data from a sample of 12 370 Soldiers who completed the 2012 US Army Global Assessment Tool (GAT). We used factor analysis to build the scale incorporating five out of eleven survey items. An IRT-driven assessment of response category properties indicates likely problems in the ordering or wording of several response categories. Group comparisons, examined with differential item functioning (DIF), provided evidence of scale validity across each Army sub-population (sex, service component and officer status). Such an approach holds promise for future FFQ.
NASA Astrophysics Data System (ADS)
Bau, Sébastien; Witschger, Olivier; Gensdarmes, François; Thomas, Dominique
2009-05-01
An increasing number of experimental and theoretical studies focus on airborne nanoparticles (NP) in relation with many aspects of risk assessment to move forward our understanding of the hazards, the actual exposures in the workplace, and the limits of engineering controls and personal protective equipment with regard to NP. As a consequence, generating airborne NP with controlled properties constitutes an important challenge. In parallel, toxicological studies have been carried out, and most of them support the concept that surface-area could be a relevant metric for characterizing exposure to airborne NP [1]. To provide NP surface-area concentration measurements, some direct-reading instruments have been designed, based on attachment rate of unipolar ions to NP by diffusion. However, very few information is available concerning the performances of these instruments and the parameters that could affect their responses. In this context, our work aims at characterizing the actual available instruments providing airborne NP surface-area concentration. The instruments (a- LQ1-DC, Matter Engineering; b-AeroTrak™ 9000, TSI; c- NSAM, TSI model 3550;) are thought to be relevant for further workplace exposure characterization and monitoring. To achieve our work, an experimental facility (named CAIMAN) was specially designed, built and characterized.
Mumbardó-Adam, C; Guàrdia-Olmos, J; Giné, C; Raley, S K; Shogren, K A
2018-04-01
A new measure of self-determination, the Self-Determination Inventory: Student Report (Spanish version), has recently been adapted and empirically validated in Spanish language. As it is the first instrument intended to measure self-determination in youth with and without disabilities, there is a need to further explore and strengthen its psychometric analysis based on item response patterns. Through item response theory approach, this study examined item observed distributions across the essential characteristics of self-determination. The results demonstrated satisfactory to excellent item functioning patterns across characteristics, particularly within agentic action domains. Increased variability across items was also found within action-control beliefs dimensions, specifically within the self-realisation subdomain. These findings further support the instrument's psychometric properties and outline future research directions. © 2017 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.
Development and psychometric validation of a child Racial Attitudes Index (RAI).
Clark, Khaya D; Yovanoff, Paul; Tate, Charlotte Ursula
2017-12-01
The Racial Attitudes Index (RAI) measures a child's racial attitudes. Designed for children aged 5-9 years, the RAI is delivered over the Internet using Audio Computer Assisted Self-Interviewing (ACASI). Unlike traditional binary forced-choice instruments, the RAI uses an expanded response format permitting a more nuanced understanding of patterns of children's racial attitudes. In addition to establishing psychometric evidence of the RAI technical adequacy, hypotheses about RAI item response patterns were tested. The racial attitudes of 336 Black and White children in grades K-3 were assessed using a forced-choice instrument (Preschool Racial Attitudes Measure II) and the RAI. Findings from this study indicate measures obtained with the RAI are technically adequate, and the measure functions invariantly across racial groups. Also, patterns of children's racial attitudes measured with the RAI are more nuanced than those obtained using the forced-choice response format.
Method for Ground-to-Satellite Laser Calibration System
NASA Technical Reports Server (NTRS)
Lukashin, Constantine (Inventor); Wielicki, Bruce A. (Inventor)
2015-01-01
The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.
Method for Ground-to-Space Laser Calibration System
NASA Technical Reports Server (NTRS)
Lukashin, Constantine (Inventor); Wielicki, Bruce A. (Inventor)
2014-01-01
The present invention comprises an approach for calibrating the sensitivity to polarization, optics degradation, spectral and stray light response functions of instruments on orbit. The concept is based on using an accurate ground-based laser system, Ground-to-Space Laser Calibration (GSLC), transmitting laser light to instrument on orbit during nighttime substantially clear-sky conditions. To minimize atmospheric contribution to the calibration uncertainty the calibration cycles should be performed in short time intervals, and all required measurements are designed to be relative. The calibration cycles involve ground operations with laser beam polarization and wavelength changes.
Prospective EUV observations of hot DA white dwarfs with the EUV Explorer
NASA Technical Reports Server (NTRS)
Finley, David S.; Malina, Roger F.; Bowyer, Stuart
1987-01-01
The Extreme Ultraviolet Explorer (EUVE) will perform a high sensitivity EUV all-sky survey. A major category of sources which will be detected with the EUVE instruments consists of hot white dwarfs. Detailed preliminary studies of synthetic EUV observations of white dwarfs have been carried out using the predicted EUVE instrumental response functions. Using available information regarding space densities of white dwarfs and the distribution of neutral hydrogen in the interstellar medium, the numbers of DA white dwarfs which will be detectable in the different EUV bandpasses have been estimated.
Even Shallower Exploration with Airborne Electromagnetics
NASA Astrophysics Data System (ADS)
Auken, E.; Christiansen, A. V.; Kirkegaard, C.; Nyboe, N. S.; Sørensen, K.
2015-12-01
Airborne electromagnetics (EM) is in many ways undergoing the same type rapid technological development as seen in the telecommunication industry. These developments are driven by a steadily increasing demand for exploration of minerals, groundwater and geotechnical targets. The latter two areas demand shallow and accurate resolution of the near surface geology in terms of both resistivity and spatial delineation of the sedimentary layers. Airborne EM systems measure the grounds electromagnetic response when subject to either a continuous discrete sinusoidal transmitter signal (frequency domain) or by measuring the decay of currents induced in the ground by rapid transmission of transient pulses (time domain). In the last decade almost all new developments of both instrument hardware and data processing techniques has focused around time domain systems. Here we present a concept for measuring the time domain response even before the transient transmitter current has been turned off. Our approach relies on a combination of new instrument hardware and novel modeling algorithms. The newly developed hardware allows for measuring the instruments complete transfer function which is convolved with the synthetic earth response in the inversion algorithm. The effect is that earth response data measured while the transmitter current is turned off can be included in the inversion, significantly increasing the amount of available information. We demonstrate the technique using both synthetic and field data. The synthetic examples provide insight on the physics during the turn off process and the field examples document the robustness of the method. Geological near surface structures can now be resolved to a degree that is unprecedented to the best of our knowledge, making airborne EM even more attractive and cost-effective for exploration of water and minerals that are crucial for the function of our societies.
Billings, Martha E; Rosen, Carol L; Auckley, Dennis; Benca, Ruth; Foldvary-Schaefer, Nancy; Iber, Conrad; Zee, Phyllis C; Redline, Susan; Kapur, Vishesh K
2014-12-01
Measures of health-related quality of life (HRQL) specific for sleep disorders have had limited psychometric evaluation in the context of randomized controlled trials (RCTs). We investigated the psychometric properties of the Functional Outcomes of Sleep Questionnaire (FOSQ) and Sleep Apnea Quality of Life Instrument (SAQLI). We evaluated the FOSQ and SAQLI construct and criterion validity, determined a minimally important difference, and assessed for associations of responsiveness to baseline subject characteristics and continuous positive airway pressure (CPAP) adherence in a RCT population. Secondary analysis of data collected in a multisite RCT of home versus laboratory-based diagnosis and treatment of obstructive sleep apnea (HomePAP trial). Individuals enrolled in the HomePAP trial (n = 335). N/A. The FOSQ and SAQLI subscores demonstrated high reliability and criterion validity, correlating with Medical Outcomes Study 36-Item Short Form Survey domains. Correlations were weaker with the Epworth Sleepiness Scale (ESS). Both the FOSQ and SAQLI scores improved after 3 mo with CPAP therapy. Averaging 4 h or more of CPAP use was associated with an increase in the FOSQ beyond the minimally important difference. Baseline depressive symptoms and sleepiness predicted FOSQ and SAQLI responsiveness; demographic, objective obstructive sleep apnea (OSA) severity and sleep habits were not predictive in linear regression. The FOSQ and SAQLI are responsive to CPAP intervention, with the FOSQ being more sensitive to differences in CPAP adherence than the SAQLI. These instruments provide unique information about health outcomes beyond that provided by changes in physiological measures of OSA severity (apnea-hypopnea index). Portable Monitoring for Diagnosis and Management of Sleep Apnea (HomePAP) URL: http://clinicaltrials.gov/show/NCT00642486. NIH clinical trials registry number: NCT00642486. © 2014 Associated Professional Sleep Societies, LLC.
SeaWiFS Technical Report Series. Volume 40; SeaWiFS Calibration Topics
NASA Technical Reports Server (NTRS)
Barnes, Robert A.; Eplee, Robert E., Jr.; Yeh, Eueng-nan; Esaias, Wayne E.
1997-01-01
For Earth-observing satellite instruments, it was standard to consider each instrument band to have a spectral response that is infinitely narrow, i.e., to have a response from a single wavelength. The SeaWiFS bands, however, have nominal spectral bandwidths of 20 and 40 nm. These bandwidths effect the SeaWiFS measurements on orbit. The effects are also linked to the manner in which the instrument was calibrated and to the spectral shape of the radiance that SeaWiFS views. The spectral shape of that radiance will not be well known on orbit. In this technical memorandum, two source spectra are examined. The first is a 12,000 K Planck function, and the second is based on the modeling results of H. Gordon at the University of Miami. By comparing these spectra, the best available corrections to the SeaWiFS measurements for source spectral shape, plus estimates of the uncertainties in these corrections, can be tabulated.
Evaluation of submarine strain-gage systems for monitoring coastal sediment migration
NASA Technical Reports Server (NTRS)
Shideler, G. L.; Mcgrath, D. G.
1973-01-01
Single and multiple strain-gage systems were respectively evaluated as in situ point and areal sensors for monitoring sand-height variations in coastal environments. Static loading tests indicate that gage response pressure is linear for sand heights up to 24 inches. Response pressures are a function of both sand height and aggregate density, with density being influenced by both sediment texture and degree of compaction. Poorer sediment sorting and greater compaction result in higher response pressures. Field tests in a beach foreshore environment indicate that the gage systems are effective qualitative instruments for monitoring long-period migration trends of beach sediments; whereas, short-period responses are not sufficiently reliable. The durability and compactness of the gage systems must be substantially increased for effective field operations. It is recommended that the systems' qualitative potentials be further developed, whereas their development as quantitative instruments be terminated. Further development should emphasize the construction of remote recording systems designed for semipermanent installation.
Pacheco-Labrador, Javier; Martín, M. Pilar
2015-01-01
Field spectroradiometers integrated in automated systems at Eddy Covariance (EC) sites are a powerful tool for monitoring and upscaling vegetation physiology and carbon and water fluxes. However, exposure to varying environmental conditions can affect the functioning of these sensors, especially if these cannot be completely insulated and stabilized. This can cause inaccuracy in the spectral measurements and hinder the comparison between data acquired at different sites. This paper describes the characterization of key sensor models in a double beam spectroradiometer necessary to calculate the Hemispherical-Conical Reflectance Factor (HCRF). Dark current, temperature dependence, non-linearity, spectral calibration and cosine receptor directional responses are modeled in the laboratory as a function of temperature, instrument settings, radiation measured or illumination angle. These models are used to correct the spectral measurements acquired continuously by the same instrument integrated outdoors in an automated system (AMSPEC-MED). Results suggest that part of the instrumental issues cancel out mutually or can be controlled by the instrument configuration, so that changes induced in HCFR reached about 0.05 at maximum. However, these corrections are necessary to ensure the inter-comparison of data with other ground or remote sensors and to discriminate instrumentally induced changes in HCRF from those related with vegetation physiology and directional effects. PMID:25679315
Elboim-Gabyzon, Michal; Agmon, Maayan; Azaiza, Faisal; Laufer, Yocheved
2015-04-24
The Late-Life Function and Disability Instrument (LLFDI) provides a comprehensive, reliable, and valid assessment of physical function and disability in community-dwelling adults. There does not appear to be a validated, comprehensive instrument for assessing function and disability in Arabic. The objective of the present study was to translate and culturally adapt the LLFDI to Arabic, and to determine its test-retest reliability and validity. The LLFDI was translated to Arabic through a forward and backward translation process, and approved by a bilingual committee of experts. Sixty-one (26 male and 35 female) Arabic speaking, healthy, older adults, ages 65-88, living in northern Israel participated in the study. To determine test-retest reliability, the questionnaire was administered twice to 41 subjects with a 6 to 8day interval. Construct validity was examined by correlating the LLFDI responses with the 10-item physical function (PF-10) subscales of the General Health Survey (SF-36), with the physical component of SF-36 (SF-36 PCS), and with two performance measures, the Berg Balance Scale (BBS) and Time Up and Go (TUG) test. Additionally, gender and fall related differences in the LLFDI were also examined. Internal consistency (Cronbach's alpha) was good to excellent (0.77 to 0.97). Test-retest agreement was good to very good (function component: 0.86-0.93, disability component: 0.77-0.93). Correlation with the SF-36 PCS and PF-10 was moderate to strong for both LLFDI components (function, r = 0.53-0.65 and r = 0.57-0.63, and LLFDI disability, r = 0.57-0.76 and 0.53-0.73, respectively). Significant, moderate-to-strong correlations between the LLFDI and BBS (r = 0.73-0.87) and a significant, moderate, negative correlation between LLFDI and TUG test (r = -0.59- -0.68) were noted. The standard error of measure was 6-12%, and the smallest real difference was 18-33%. Discriminative validity for both gender and fall status were also demonstrated. The Arabic version of the LLFDI is a highly reliable and valid instrument for assessing function and disability in community dwelling, Arab older adults. The translated instrument has a discriminative ability between genders and between fallers and non-fallers. The translated instrument may be used in clinical settings and for research purposes.
Marfeo, Elizabeth E; Ni, Pengsheng; Haley, Stephen M; Bogusz, Kara; Meterko, Mark; McDonough, Christine M; Chan, Leighton; Rasch, Elizabeth K; Brandt, Diane E; Jette, Alan M
2013-09-01
To use item response theory (IRT) data simulations to construct and perform initial psychometric testing of a newly developed instrument, the Social Security Administration Behavioral Health Function (SSA-BH) instrument, that aims to assess behavioral health functioning relevant to the context of work. Cross-sectional survey followed by IRT calibration data simulations. Community. Sample of individuals applying for Social Security Administration disability benefits: claimants (n=1015) and a normative comparative sample of U.S. adults (n=1000). None. SSA-BH measurement instrument. IRT analyses supported the unidimensionality of 4 SSA-BH scales: mood and emotions (35 items), self-efficacy (23 items), social interactions (6 items), and behavioral control (15 items). All SSA-BH scales demonstrated strong psychometric properties including reliability, accuracy, and breadth of coverage. High correlations of the simulated 5- or 10-item computer adaptive tests with the full item bank indicated robust ability of the computer adaptive testing approach to comprehensively characterize behavioral health function along 4 distinct dimensions. Initial testing and evaluation of the SSA-BH instrument demonstrated good accuracy, reliability, and content coverage along all 4 scales. Behavioral function profiles of Social Security Administration claimants were generated and compared with age- and sex-matched norms along 4 scales: mood and emotions, behavioral control, social interactions, and self-efficacy. Using the computer adaptive test-based approach offers the ability to collect standardized, comprehensive functional information about claimants in an efficient way, which may prove useful in the context of the Social Security Administration's work disability programs. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Perera, Subashan; Nace, David A; Resnick, Neil M; Greenspan, Susan L
2017-04-11
The Nursing Home Physical Performance Test (NHPPT) was developed to measure function among nursing home residents using sit-to-stand, scooping applesauce, face washing, dialing phone, putting on sweater, and ambulating tasks. Using item response theory, we explore its measurement characteristics at item level and opportunities for improvements. We used data from long-term care women. We fitted a graded response model, estimated parameters, and constructed probability and information curves. We identified items to be targeted toward lower and higher functioning persons to increase the range of abilities to which the instrument is applicable. We revised the scoring by making sit-to-stand and sweater items harder and dialing phone easier. We examined changes to concurrent validity with activities of daily living (ADL), frailty, and cognitive function. Participants were 86 years old, had more than three comorbidities, and a NHPPT of 19.4. All items had high discrimination and were targeted toward the lower middle range of performance continuum. After revision, sit-to-stand and sweater items demonstrated greater discrimination among the higher functioning and/or greater spread of thresholds for response categories. The overall test showed discrimination over a wider range of individuals. Concurrent validity correlation improved from 0.60 to 0.68 for instrumental ADL and explained variability (R2) from 22% to 36% for frailty. NHPPT has good measurement characteristics at the item level. NHPPT can be improved, implemented in computerized adaptive testing, and combined with self-report for greater utility, but a definitive study is needed. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
A Chemiluminescence Detector for Ozone Measurement.
ERIC Educational Resources Information Center
Carroll, H.; And Others
An ozone detector was built and evaluated for its applicability in smog chamber studies. The detection method is based on reaction of ozone with ethylene and measurement of resultant chemiluminescence. In the first phase of evaluation, the detector's response to ozone was studied as a function of several instrument parameters, and optimum…
Experimental evidence for partial spatial coherence in imaging Mueller polarimetry.
Ossikovski, Razvigor; Arteaga, Oriol; Yoo, Sang Hyuk; Garcia-Caurel, Enric; Hingerl, Kurt
2017-11-15
We demonstrate experimentally the validity of the partial spatial coherence formalism in Mueller polarimetry and show that, in a finite spatial resolution experiment, the measured response is obtained through convolving the theoretical one with the instrument function. The reported results are of primary importance for Mueller imaging systems.
A Rasch Analysis of the Junior Metacognitive Awareness Inventory with Singapore Students
ERIC Educational Resources Information Center
Ning, Hoi Kwan
2018-01-01
The psychometric properties of the 2 versions of the Junior Metacognitive Awareness Inventory were examined with Singapore student samples. Other than 2 misfitting items and an underutilized response scale, Rasch analysis demonstrated that the instruments have good measurement precision, and no differential item functioning was detected across…
Evaluation of Verbal Behavior in Older Adults
Gross, Amy C.; Fuqua, R. Wayne; Merritt, Todd A.
2013-01-01
Approximately 5% of older adults have a dementia diagnosis, and language deterioration is commonly associated with this disorder (Kempler, 2005). Several instruments have been developed to diagnose dementia and assess language capabilities of elderly adults. However, none of these instruments take a functional approach to language assessment as described by Skinner (1957). The purpose of this study was to develop and evaluate a function-based assessment for language deficits of older adults. Thirty-one participants were categorized into a control group (n = 15) and a dementia group (n = 16) based on their score on the Dementia Rating Scale-2. Individuals with dementia performed significantly worse on the tact assessment than those without dementia. Participants from both groups performed better on measures of tacts than intraverbals or mands, even though topographically identical responses were required in these assessments. The data provide support for Skinner's conceptualization of functionally independent verbal operants. PMID:23814369
UFFO/ Lomonosov: The Payload for the Observation of Early Photons from Gamma Ray Bursts
NASA Astrophysics Data System (ADS)
Park, I. H.; Panasyuk, M. I.; Reglero, V.; Chen, P.; Castro-Tirado, A. J.; Jeong, S.; Bogomolov, V.; Brandt, S.; Budtz-Jørgensen, C.; Chang, S.-H.; Chang, Y. Y.; Chen, C.-R.; Chen, C.-W.; Choi, H. S.; Connell, P.; Eyles, C.; Gaikov, G.; Garipov, G.; Huang, J.-J.; Huang, M.-H. A.; Jeong, H. M.; Kim, J. E.; Kim, M. B.; Kim, S.-W.; Lee, H. K.; Lee, J.; Lim, H.; Lin, C.-Y.; Liu, T.-C.; Nam, J. W.; Petrov, V.; Ripa, J.; Rodrigo, J. M.; Svertilov, S.; Wang, M.-Z.; Yashin, I.
2018-02-01
The payload of the UFFO (Ultra-Fast Flash Observatory)-pathfinder now onboard the Lomonosov spacecraft (hereafter UFFO/ Lomonosov) is a dedicated instrument for the observation of GRBs. Its primary aim is to capture the rise phase of the optical light curve, one of the least known aspects of GRBs. Fast response measurements of the optical emission of GRB will be made by a Slewing Mirror Telescope (SMT), a key instrument of the payload, which will open a new frontier in transient studies by probing the early optical rise of GRBs with a response time in seconds for the first time. The SMT employs a rapidly slewing mirror to redirect the optical axis of the telescope to a GRB position prior determined by the UFFO Burst Alert Telescope (UBAT), the other onboard instrument, for the observation and imaging of X-rays. UFFO/Lomonosov was launched successfully from Vostochny, Russia on April 28, 2016, and will begin GRB observations after completion of functional checks of the Lomonosov spacecraft. The concept of early GRB photon measurements with UFFO was reported in 2012. In this article, we will report in detail the first mission, UFFO/Lomonosov, for the rapid response to GRB observations.
NASA Astrophysics Data System (ADS)
Fernandes, P. A.; Lynch, K. A.; Zettergren, M. D.; Hampton, D. L.; Fisher, L. E.; Powell, S. P.
2013-12-01
The MICA sounding rocket launched on 19 Feb. 2012 into several discrete, localized arcs in the wake of a westward traveling surge. In situ and ground-based observations provide a measured response of the ionosphere to preflight and localized auroral drivers. In this presentation we focus on in situ measurements of the thermal ion distribution. We observe thermal ions flowing both up and down the auroral field line, with upflows concentrated in Alfvénic and downward current regions. The in situ data are compared with recent ionospheric modeling efforts (Zettergren et al., this session) which show structured patterns of ion upflow and downflow consistent with these observations. In the low-energy thermal plasma regime, instrument response to the measured thermal ion population is very sensitive to the presence of the instrument. The plasma is shifted and accelerated in the frame of the instrument due to flows, ram, and acceleration through the payload sheath. The energies associated with these processes are large compared to the thermal energy. Rigorous quantitative analysis of the instrument response is necessary to extract the plasma properties which describe the full 3D distribution function at the instrument aperture. We introduce an instrument model, developed in the commercial software package SIMION, to characterize instrument response at low energies. The instrument model provides important insight into how we would modify our instrument for future missions, including fine-tuning parameters such as the analyzer sweep curve, the geometry factor, and the aperture size. We use the results from the instrument model to develop a forward model, from which we can extract anisotropic ion temperatures, flows, and density of the thermal plasma at the aperture. Because this plasma has transited a sheath to reach the aperture, we must account for the acceleration due to the sheath. Modeling of this complex sheath is being conducted by co-author Fisher, using a PIC code created with the Spacecraft Plasma Interaction Software (SPIS). Once we have coupled the instrument and forward models to this sophisticated sheath model, we can rigorously extract the properties of the background thermal plasma. These thermal plasma measurements are used to address questions of ionospheric-thermospheric coupling. These questions for MICA and its modeling efforts include the following: is the state of the ionosphere during the rocket flight a remnant of the westward traveling surge, or is it a direct response to localized drivers? How do the calculated ion flows compare to the flows derived from the electric field data, and what do these flows tell us about the state of the ionosphere? How do the MICA measurements of ion upflows and downflows tie into the broader sounding rocket ion parallel flow study presented by Lynch et al. (this session) and into the Zettergren and Semeter, [2012] 2D, ionospheric fluid/electrostatic model?
Pampel, Michael; Jakstat, Holger A; Ahlers, Oliver M
2014-01-01
Playing a wind instrument can be either a reason for overuse or a protecting factor against certain diseases. Some individuals have many findings but low morbidity while others have few findings but high morbidity. This contradictory phenomenon should be researched. The temporomandibular system (TMS) is a functional unit which comprises the mandible, associated muscles and bilateral joints with the temporal bone. The TMS is responsible for the generation of sound when wind instruments are played. Over the long-term and with intensive usage, this causes changes in the musculature and in the temporomandibular joint (TMJ) of wind musicians, often resulting in temporomandibular disorders (TMD). The aim of this study is to examine evidence that TMD constitute an occupational disease in wind musicians. TMD patients and wind musicians were examined by dental clinical functional analysis. 102 male subjects were divided into three groups: "healthy" individuals, wind musicians, and patients with TMD. Dental Examination was carried out based on focused inclusion of the research diagnostic criteria - TMD [1,7]. Findings were evaluated for statistical significance by first transferring data into a digital database [2,15], then generating T-Test und Wilcoxon-Test when non-Gaussian distribution appears and applying the Mann-Whitney rank sum test using Sigmaplot Version 1.1 software (Systat Software Inc, Washington, USA). The evaluation revealed that wind instrument musicians show a high incidence of developing TMD as the researchers found almost 100% morbidity regarding parafunctional habits and preauricular muscle pain of each adult and highly active musician. The result is highly significant (p< 0.001) for protrusion distance of the mandible. A higher prevalence of functional disorders of the musculoskeletal system has previously been demonstrated in wind musicians. New research results and the typical functions of various wind instruments provide evidence that playing a wind instrument generates occupational risks to the TMS.
[Cardiovascular circulation feedback control treatment instrument].
Ge, Yu-zhi; Zhu, Xing-huan; Sheng, Guo-tai; Cao, Ping-liang; Liu, Dong-sheng; Wu, Zhi-ting
2005-07-01
The cardiovascular circulation feedback control treatment instrument (CFCTI) is an automatic feedback control treatment system, which has the function of monitoring, alarming, trouble self-diagnosis and testing on the line in the closed loop. The instrument is designed based on the successful clinical experiences and the data are inputted into the computer in real-time through a pressure sensor and A/D card. User interface window is set up for the doctor's choosing different medicine. The orders are outputted to control the dose of medicine through the transfusion system. The response to medicine is updated continually. CFCTI can avoid the man-made errors and the long interval of sampling. Its reliability and accuracy in rescuing the critical patients are much higher than the traditional methods.
The control unit of the near infrared spectrograph of the Euclid space mission: detailed design
NASA Astrophysics Data System (ADS)
Toledo-Moreo, Rafael; Colodro-Conde, Carlos; Gómez-Sáenz-de-Tejada, Jaime; Pérez-Lizán, David; Díaz-García, José Javier; Tubío-Araujo, Óscar; Raichs, Cayetano; Catalán, Jordi; Rebolo-López, Rafael
2016-07-01
The Near Infrared Spectrograph and Photometer (NISP) is one of the instruments on board the ESA EUCLID mission. The Universidad Politécnica de Cartagena and Instituto de Astrofísica de Canarias are responsible of the Instrument Control Unit of the NISP (NI-ICU) in the Euclid Consortium. The NI-ICU hardware is developed by CRISA (Airbus Defence and Space), and its main functions are: communication with the S/C and the Data Processing Unit, control of the Filter and Grism Wheels, control of the Calibration Unit and thermal control of the instrument. This paper presents the NI-ICU status of definition and design at the end of the detailed design phase.
Spatial sampling considerations of the CERES (Clouds and Earth Radiant Energy System) instrument
NASA Astrophysics Data System (ADS)
Smith, G. L.; Manalo-Smith, Natividdad; Priestley, Kory
2014-10-01
The CERES (Clouds and Earth Radiant Energy System) instrument is a scanning radiometer with three channels for measuring Earth radiation budget. At present CERES models are operating aboard the Terra, Aqua and Suomi/NPP spacecraft and flights of CERES instruments are planned for the JPSS-1 spacecraft and its successors. CERES scans from one limb of the Earth to the other and back. The footprint size grows with distance from nadir simply due to geometry so that the size of the smallest features which can be resolved from the data increases and spatial sampling errors increase with nadir angle. This paper presents an analysis of the effect of nadir angle on spatial sampling errors of the CERES instrument. The analysis performed in the Fourier domain. Spatial sampling errors are created by smoothing of features which are the size of the footprint and smaller, or blurring, and inadequate sampling, that causes aliasing errors. These spatial sampling errors are computed in terms of the system transfer function, which is the Fourier transform of the point response function, the spacing of data points and the spatial spectrum of the radiance field.
Aerosol optical depth determination in the UV using a four-channel precision filter radiometer
NASA Astrophysics Data System (ADS)
Carlund, Thomas; Kouremeti, Natalia; Kazadzis, Stelios; Gröbner, Julian
2017-03-01
The determination of aerosol properties, especially the aerosol optical depth (AOD) in the ultraviolet (UV) wavelength region, is of great importance for understanding the climatological variability of UV radiation. However, operational retrievals of AOD at the biologically most harmful wavelengths in the UVB are currently only made at very few places. This paper reports on the UVPFR (UV precision filter radiometer) sunphotometer, a stable and robust instrument that can be used for AOD retrievals at four UV wavelengths. Instrument characteristics and results of Langley calibrations at a high-altitude site were presented. It was shown that due to the relatively wide spectral response functions of the UVPFR, the calibration constants (V0) derived from Langley plot calibrations underestimate the true extraterrestrial signals. Accordingly, correction factors were introduced. In addition, the instrument's spectral response functions also result in an apparent air-mass-dependent decrease in ozone optical depth used in the AOD determinations. An adjusted formula for the calculation of AOD, with a correction term dependent on total column ozone amount and ozone air mass, was therefore introduced. Langley calibrations performed 13-14 months apart resulted in sensitivity changes of ≤ 1.1 %, indicating good instrument stability. Comparison with a high-accuracy standard precision filter radiometer, measuring AOD at 368-862 nm wavelengths, showed consistent results. Also, very good agreement was achieved by comparing the UVPFR with AOD at UVB wavelengths derived with a Brewer spectrophotometer, which was calibrated against the UVPFR at an earlier date. Mainly due to non-instrumental uncertainties connected with ozone optical depth, the total uncertainty of AOD in the UVB is higher than that reported from AOD instruments measuring in UVA and visible ranges. However, the precision can be high among instruments using harmonized algorithms for ozone and Rayleigh optical depth as well as for air mass terms. For 4 months of comparison measurements with the UVPFR and a Brewer, the root mean squared AOD differences were found < 0.01 at all the 306-320 nm Brewer wavelengths.
Respiratory function in wind instrument players.
Zuskin, Eugenija; Mustajbegovic, Jadranka; Schachter, E N; Kern, Josipa; Vitale, Ksenija; Pucarin-Cvetkovic, Jasna; Chiarelli, A; Milosevic, M; Jelinic, Jagoda Doko
2009-01-01
The playing of wind instruments has been associated with changes in respiratory function. To investigate the effect of playing wind instruments on lung function and respiratory symptoms. The present study included 99 wind instrument players and a group of 41 string instrument players as a control from 3 major orchestras in Zagreb, Croatia. Data on chronic respiratory symptoms were recorded in all studied subjects. Lung function was measured in wind instrument players by recording maximum expiratory flow-volume curves. Wind instrument players demonstrated significantly higher prevalences of sinusitis, nasal catarrh and hoarseness compared to control musicians. One wind instrument player developed asthma associated with his work. Odds ratios for wind instrument players were significant for chronic cough, chronic phlegm and chronic bronchitis by smoking habit (p<0.05 or p<0.01) but not for length of employment. Ventilatory capacity data indicate that wind instrument players had significantly greater FEV1 (smokers and nonsmokers) as well as FEF50 (nonsmokers) (p<0.05) compared to predicted values. Regression analysis of pulmonary function tests in wind instrument players demonstrate a significant link between FEV1 and FEF50 and length of employment. Those wind instrument players with longer employment had the greatest increases in lung function. Our data suggest that musicians playing wind instruments may be susceptible to chronic upper airway symptoms. Interestingly wind instrument playing may be associated with higher than expected lung function parameters.
Li, Xiaoli; Liu, Xiaomin
2014-01-01
In the last two decades, functional near-infrared spectroscopy (fNIRS) is getting more and more popular as a neuroimaging technique. The fNIRS instrument can be used to measure local hemodynamic response, which indirectly reflects the functional neural activities in human brain. In this study, an easily implemented way to establish DAQ-device-based fNIRS system was proposed. Basic instrumentation components (light sources driving, signal conditioning, sensors, and optical fiber) of the fNIRS system were described. The digital in-phase and quadrature demodulation method was applied in LabVIEW software to distinguish light sources from different emitters. The effectiveness of the custom-made system was verified by simultaneous measurement with a commercial instrument ETG-4000 during Valsalva maneuver experiment. The light intensity data acquired from two systems were highly correlated for lower wavelength (Pearson's correlation coefficient r = 0.92, P < 0.01) and higher wavelength (r = 0.84, P < 0.01). Further, another mental arithmetic experiment was implemented to detect neural activation in the prefrontal cortex. For 9 participants, significant cerebral activation was detected in 6 subjects (P < 0.05) for oxyhemoglobin and in 8 subjects (P < 0.01) for deoxyhemoglobin. PMID:25180044
Wiitavaara, Birgitta; Heiden, Marina
2017-06-02
The purpose was to investigate how physical function is assessed in people with musculoskeletal disorders (MSD) in the neck. Specifically, we aimed to determine: (1) Which questionnaires are used to assess physical function in people with MSD in the neck? (2) What do those questionnaires measure? (3) What are the measurement properties of the questionnaires? A systematic review was performed to identify questionnaires and psychometric evaluations. The content of the questionnaires was categorized according to the International Classification of Function, Disability and Health, and the psychometric properties were quality-rated using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. Ten questionnaires and 32 articles evaluating measurement properties were analyzed. Most questionnaires covered only the components body functions and activity and participation, more often activity participation than body function. Internal consistency was adequate in most questionnaires, whereas responsiveness was generally low. Neck Disability Index was most evaluated, but the evaluations of all questionnaires tended to cover most properties in the checklist. The questionnaires differed substantially in items and extent to which their psychometric properties had been evaluated. Focus of measurement was on activities in daily life rather than physical function as such. Implications for Rehabilitation To provide early diagnostics and effective treatment for patients with neck disorders, valid and reliable instruments that measure relevant aspects of the disorders are needed. This paper presents an overview of content and quality of questionnaires used to assess physical function in neck disorders, which may facilitate informed decisions about which measurement instruments to use when evaluating the course of neck disorders. Most of the questionnaires need more testing to judge the quality, however the NDI was the most frequently tested questionnaire. The COnsensus-based Standards for the selection of health Measurement INstruments checklist is a useful tool in relation to psychometric testing of questionnaires, but clear definitions of interpretation of the quality criteria in each study would enhance comparability of results.
Reliability of the Foot Function Index:: A report of the AOFAS Outcomes Committee..
Agel, Julie; Beskin, James L; Brage, Michael; Guyton, Gregory P; Kadel, Nancy J; Saltzman, Charles L; Sands, Andrew K; Sangeorzan, Bruce J; SooHoo, Nelson F; Stroud, Chris C; Thordarson, David B
2005-11-01
There currently is no widely used, validated, self-administered instrument for measuring musculoskeletal functional status in individuals with nonsystemic foot disorders. The purpose of this paper was to report on the assessment of reliability of one of these instruments. We wanted to determine if the Foot Function Index (FFI), which has been validated in rheumatoid patients without fixed foot deformity or prior foot surgery, would be reliable for a population of patients with foot complaints without systemic disease. Patients were recruited from five orthopaedic offices where the physicians were members of the American Orthopaedic Foot and Ankle Society. Patients were asked to complete the FFI at the time of their initial office visit and then were given a second copy to complete and return by mail 1 week after their visit. Ninety-six patients completed the first questionnaire, and 54 patients completed the second. Reliability in this population was acceptable with an average of 23.5% of the patients providing retest values within one point of the initial response and an average of 45.3% of the patients providing the same response, for a total of 68.8% of all respondents answering within one point between their initial and second questionnaire. In two of the three categories, there were frequent nonresponses or no applicable responses. Four questions, two in the pain section and two in the activity limitation section, generated 20% or more of the nonapplicable answers. The FFI appears to be a reasonable tool for low functioning individuals with foot disorders. It may not be appropriate for individuals who function at or above the level of independent activities of daily living.
An instrumental variable random-coefficients model for binary outcomes
Chesher, Andrew; Rosen, Adam M
2014-01-01
In this paper, we study a random-coefficients model for a binary outcome. We allow for the possibility that some or even all of the explanatory variables are arbitrarily correlated with the random coefficients, thus permitting endogeneity. We assume the existence of observed instrumental variables Z that are jointly independent with the random coefficients, although we place no structure on the joint determination of the endogenous variable X and instruments Z, as would be required for a control function approach. The model fits within the spectrum of generalized instrumental variable models, and we thus apply identification results from our previous studies of such models to the present context, demonstrating their use. Specifically, we characterize the identified set for the distribution of random coefficients in the binary response model with endogeneity via a collection of conditional moment inequalities, and we investigate the structure of these sets by way of numerical illustration. PMID:25798048
NASA Technical Reports Server (NTRS)
Biddle, A. P.; Reynolds, J. M.
1986-01-01
The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.
A Quantitative Evaluation of Dissolved Oxygen Instrumentation
NASA Technical Reports Server (NTRS)
Pijanowski, Barbara S.
1971-01-01
The implications of the presence of dissolved oxygen in water are discussed in terms of its deleterious or beneficial effects, depending on the functional consequences to those affected, e.g., the industrialist, the oceanographer, and the ecologist. The paper is devoted primarily to an examination of the performance of five commercially available dissolved oxygen meters. The design of each is briefly reviewed and ease or difficulty of use in the field described. Specifically, the evaluation program treated a number of parameters and user considerations including an initial check and trial calibration for each instrument and a discussion of the measurement methodology employed. Detailed test results are given relating to the effects of primary power variation, water-flow sensitivity, response time, relative accuracy of dissolved-oxygen readout, temperature accuracy (for those instruments which included this feature), error and repeatability, stability, pressure and other environmental effects, and test results obtained in the field. Overall instrument performance is summarized comparatively by chart.
Modeling the Proton Radiation Belt With Van Allen Probes Relativistic Electron-Proton Telescope Data
NASA Technical Reports Server (NTRS)
Kanekal, S. G.; Li, X.; Baker, D. N.; Selesnick, R. S.; Hoxie, V. C.
2018-01-01
An empirical model of the proton radiation belt is constructed from data taken during 2013-2017 by the Relativistic Electron-Proton Telescopes on the Van Allen Probes satellites. The model intensity is a function of time, kinetic energy in the range 18-600 megaelectronvolts, equatorial pitch angle, and L shell of proton guiding centers. Data are selected, on the basis of energy deposits in each of the nine silicon detectors, to reduce background caused by hard proton energy spectra at low L. Instrument response functions are computed by Monte Carlo integration, using simulated proton paths through a simplified structural model, to account for energy loss in shielding material for protons outside the nominal field of view. Overlap of energy channels, their wide angular response, and changing satellite orientation require the model dependencies on all three independent variables be determined simultaneously. This is done by least squares minimization with a customized steepest descent algorithm. Model uncertainty accounts for statistical data error and systematic error in the simulated instrument response. A proton energy spectrum is also computed from data taken during the 8 January 2014 solar event, to illustrate methods for the simpler case of an isotropic and homogeneous model distribution. Radiation belt and solar proton results are compared to intensities computed with a simplified, on-axis response that can provide a good approximation under limited circumstances.
Modeling the Proton Radiation Belt With Van Allen Probes Relativistic Electron-Proton Telescope Data
NASA Astrophysics Data System (ADS)
Selesnick, R. S.; Baker, D. N.; Kanekal, S. G.; Hoxie, V. C.; Li, X.
2018-01-01
An empirical model of the proton radiation belt is constructed from data taken during 2013-2017 by the Relativistic Electron-Proton Telescopes on the Van Allen Probes satellites. The model intensity is a function of time, kinetic energy in the range 18-600 MeV, equatorial pitch angle, and L shell of proton guiding centers. Data are selected, on the basis of energy deposits in each of the nine silicon detectors, to reduce background caused by hard proton energy spectra at low L. Instrument response functions are computed by Monte Carlo integration, using simulated proton paths through a simplified structural model, to account for energy loss in shielding material for protons outside the nominal field of view. Overlap of energy channels, their wide angular response, and changing satellite orientation require the model dependencies on all three independent variables be determined simultaneously. This is done by least squares minimization with a customized steepest descent algorithm. Model uncertainty accounts for statistical data error and systematic error in the simulated instrument response. A proton energy spectrum is also computed from data taken during the 8 January 2014 solar event, to illustrate methods for the simpler case of an isotropic and homogeneous model distribution. Radiation belt and solar proton results are compared to intensities computed with a simplified, on-axis response that can provide a good approximation under limited circumstances.
Eechaute, Christophe; Vaes, Peter; Van Aerschot, Lieve; Asman, Sara; Duquet, William
2007-01-18
The assessment of outcomes from the patient's perspective becomes more recognized in health care. Also in patients with chronic ankle instability, the degree of present impairments, disabilities and participation problems should be documented from the perspective of the patient. The decision about which patient-assessed instrument is most appropriate for clinical practice should be based upon systematic reviews. Only rating scales constructed for patients with acute ligament injuries were systematically reviewed in the past. The aim of this study was to review systematically the clinimetric qualities of patient-assessed instruments designed for patients with chronic ankle instability. A computerized literature search of Medline, Embase, Cinahl, Web of Science, Sport Discus and the Cochrane Controlled Trial Register was performed to identify eligible instruments. Two reviewers independently evaluated the clinimetric qualities of the selected instruments using a criteria list. The inter-observer reliability of both the selection procedure and the clinimetric evaluation was calculated using modified kappa coefficients. The inter-observer reliability of the selection procedure was excellent (k = .86). Four instruments met the eligibility criteria: the Ankle Joint Functional Assessment Tool (AJFAT), the Functional Ankle Outcome Score (FAOS), the Foot and Ankle Disability Index (FADI) and the Functional Ankle Ability Measure (FAAM). The inter-observer reliability of the quality assessment was substantial to excellent (k between .64 and .88). Test-retest reliability was demonstrated for the FAOS, the FADI and the FAAM but not for the AJFAT. The FAOS and the FAAM met the criteria for content validity and construct validity. For none of the studied instruments, the internal consistency was sufficiently demonstrated. The presence of floor- and ceiling effects was assessed for the FAOS but ceiling effects were present for all subscales. Responsiveness was demonstrated for the AJFAT, FADI and the FAAM. Only for the FAAM, a minimal clinical important difference (MCID) was presented. The FADI and the FAAM can be considered as the most appropriate, patient-assessed tools to quantify functional disabilities in patients with chronic ankle instability. The clinimetric qualities of the FAAM need to be further demonstrated in a specific population of patients with chronic ankle instability.
Double difference method in deep inelastic neutron scattering on the VESUVIO spectrometer
NASA Astrophysics Data System (ADS)
Andreani, C.; Colognesi, D.; Degiorgi, E.; Filabozzi, A.; Nardone, M.; Pace, E.; Pietropaolo, A.; Senesi, R.
2003-02-01
The principles of the Double Difference (DD) method, applied to the neutron spectrometer VESUVIO, are discussed. VESUVIO, an inverse geometry spectrometer operating at the ISIS pulsed neutron source in the eV energy region, has been specifically designed to measure the single particle dynamical properties in condensed matter. The width of the nuclear resonance of the absorbing filter, used for the neutron energy analysis, provides the most important contribution to the energy resolution of the inverse geometry instruments. In this paper, the DD method, which is based on a linear combination of two measurements recorded with filter foils of the same resonance material but of different thickness, is shown to improve significantly the instrumental energy resolution, as compared with the Single Difference (SD) method. The asymptotic response functions, derived through Monte-Carlo simulations for polycrystalline Pb and ZrH 2 samples, are analysed in both DD and SD methods, and compared with the experimental ones for Pb sample. The response functions have been modelled for two distinct experimental configurations of the VESUVIO spectrometer, employing 6Li-glass neutron detectors and NaI γ detectors revealing the γ-ray cascade from the ( n,γ) reaction, respectively. The DD method appears to be an effective experimental procedure for Deep Inelastic Neutron Scattering measurements on VESUVIO spectrometer, since it reduces the experimental resolution of the instrument in both 6Li-glass neutron detector and γ detector configurations.
DOT National Transportation Integrated Search
1973-04-01
Eighteen instrument-rated pilots were flown in two-hour simulated solo missions during which the frequency of traffic, ATC warnings, and ATC clearances were varied, while the visibility of the target was held constant at 100%. : In order to observe t...
NASA Technical Reports Server (NTRS)
Barnes, Robert A.; Brown, Steven W.; Lykke, Keith R.; Guenther, Bruce; Xiong, Xiaoxiong (Jack); Butler, James J.
2010-01-01
Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance response in a two-step method. In the first step, the spectral response of the instrument is determined using a nearly monochromatic light source, such a lamp-illuminated monochromator. Such sources only provide a relative spectral response (RSR) for the instrument, since they do not act as calibrated sources of light nor do they typically fill the field-of-view of the instrument. In the second step, the instrument views a calibrated source of broadband light, such as lamp-illuminated integrating sphere. In the traditional method, the RSR and the sphere spectral radiance are combined and, with the instrument's response, determine the absolute spectral radiance responsivity of the instrument. More recently, an absolute calibration system using widely tunable monochromatic laser systems has been developed, Using these sources, the absolute spectral responsivity (ASR) of an instrument can be determined on a wavelength-hy-wavelength basis. From these monochromatic ASRs. the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as integrating spheres. Here we describe the laser-based calibration and the traditional broad-band source-based calibration of the NPP VIIRS sensor, and compare the derived calibration coefficients for the instrument. Finally, we evaluate the impact of the new calibration approach on the on-orbit performance of the sensor.
Rasch Analysis of the Student Refractive Error and Eyeglass Questionnaire
Crescioni, Mabel; Messer, Dawn H.; Warholak, Terri L.; Miller, Joseph M.; Twelker, J. Daniel; Harvey, Erin M.
2014-01-01
Purpose To evaluate and refine a newly developed instrument, the Student Refractive Error and Eyeglasses Questionnaire (SREEQ), designed to measure the impact of uncorrected and corrected refractive error on vision-related quality of life (VRQoL) in school-aged children. Methods. A 38 statement instrument consisting of two parts was developed: Part A relates to perceptions regarding uncorrected vision and Part B relates to perceptions regarding corrected vision and includes other statements regarding VRQoL with spectacle correction. The SREEQ was administered to 200 Native American 6th through 12th grade students known to have previously worn and who currently require eyeglasses. Rasch analysis was conducted to evaluate the functioning of the SREEQ. Statements on Part A and Part B were analyzed to examine the dimensionality and constructs of the questionnaire, how well the items functioned, and the appropriateness of the response scale used. Results Rasch analysis suggested two items be eliminated and the measurement scale for matching items be reduced from a 4-point response scale to a 3-point response scale. With these modifications, categorical data were converted to interval level data, to conduct an item and person analysis. A shortened version of the SREEQ was constructed with these modifications, the SREEQ-R, which included the statements that were able to capture changes in VRQoL associated with spectacle wear for those with significant refractive error in our study population. Conclusions While the SREEQ Part B appears to be a have less than optimal reliability to assess the impact of spectacle correction on VRQoL in our student population, it is also able to detect statistically significant differences from pretest to posttest on both the group and individual levels to show that the instrument can assess the impact that glasses have on VRQoL. Further modifications to the questionnaire, such as those included in the SREEQ-R, could enhance its functionality. PMID:24811844
Development and Validation of a Quality-of-Life Instrument for Infantile Hemangiomas.
Chamlin, Sarah L; Mancini, Anthony J; Lai, Jin-Shei; Beaumont, Jennifer L; Cella, David; Adams, Denise; Drolet, Beth; Baselga, Eulalia; Frieden, Ilona J; Garzon, Maria; Holland, Kristin; Horii, Kimberly A; Lucky, Anne W; McCuaig, Catherine; Metry, Denise; Morel, Kimberly D; Newell, Brandon D; Nopper, Amy J; Powell, Julie; Siegel, Dawn; Haggstrom, Anita N
2015-06-01
Infantile hemangiomas (IH) are common tumors for which there is no validated disease-specific instrument to measure the quality of life in infants and their parents/caregivers during the critical first months of life. This study prospectively developed and validated a quality-of-life instrument for patients with IH and their parents/caregivers and correlated demographic and clinical features to the effects on the quality of life. A total of 220 parents/caregivers completed the 35-item Infantile Hemangioma Quality-of-Life (IH-QoL) instrument and provided demographic information. The dimensionality of the items was evaluated using factor analysis, with results suggesting four factors: child physical symptoms, child social interactions, parent emotional functioning, and parent psychosocial functioning. Each factor fit the Rasch measurement model with acceptable fit index (mean square <1.4) and demonstrated excellent internal consistency, with alpha ranging from 0.76 to 0.88. The final instrument consists of four scales with a total of 29 items. Content validity was verified by analyzing parents' responses to an open-ended question. Test-retest reliability at a 48-hour interval was supported by a total IH-QoL intraclass correlation coefficient of 0.84. Certain clinical characteristics of hemangioma, including those located on the head and neck, in the proliferative stage, and requiring treatment, are associated with a greater impact on QoL.
Horwitz, Daniel S; Richard, Raveesh D; Suk, Michael
2014-01-01
Orthopaedic journals, such as the Journal of Orthopaedic Trauma, frequently publish studies reporting functional outcome instruments, but little information has been provided regarding the validity and overall strength of these instruments. This study analyzes the trends in reported functional outcome instruments in articles published in the Journal of Orthopaedic Trauma over a 5-year period and examines the utilization rate, "overall" strength, and validity of these functional outcome instruments for the populations being studied. Articles that were published in the Journal of Orthopaedic Trauma from January 2006 to December 2010 were reviewed, and each article was assigned to 1 of 4 different categories, based on the subspecialty focus and body region. The total number of articles reporting the use of functional outcome instruments, articles with at least 1 functional outcome instrument found in the AO Handbook, and the total number of functional outcome instruments reported were recorded. Each functional outcome instrument was assigned to 1 of 3 categories (generic, nonvalidated, validated), and each validated instrument was also examined to determine whether the category of interest for which it was used was one in which it was previously validated in. A total of 171 articles (34%) of the articles initially reviewed met the inclusion criteria. The average number of articles per year that reported functional outcome instruments was 56% (range, 47%-65%), and the average number of articles that reported at least 1 validated outcome instrument was 51% (range, 44%-61%). The average percentage of validated scores that were appropriately used within the category of interest was 23% (range, 13%-41%). Even though the 56% utilization rate of functional outcome instruments in The Journal of Orthopaedic Trauma is much higher than other journals, it is still low given the importance of measuring and attaining excellent functional outcomes. It is clear that future effort should be given to validating outcome measures for correct evaluation of orthopaedic trauma patients.
Adam, R.; Ade, P. A. R.; Aghanim, N.; ...
2016-09-20
The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full mission TOI is included in the Planck 2015 release. This study describes the HFI TOI and beam processing for the 2015 release. HFI calibration and map making are described in a companion paper. The mainmore » pipeline has been modified since the last release (2013 nominal mission in intensity only), by including a correction for the nonlinearity of the warm readout and by improving the model of the bolometer time response. The beam processing is an essential tool that derives the angular response used in all the Planck science papers and we report an improvement in the effective beam window function uncertainty of more than a factor of 10 relative to the2013 release. Noise correlations introduced by pipeline filtering function are assessed using dedicated simulations. Finally, angular cross-power spectra using data sets that are decorrelated in time are immune to the main systematic effects.« less
NASA Astrophysics Data System (ADS)
Planck Collaboration; Adam, R.; Ade, P. A. R.; Aghanim, N.; Arnaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bertincourt, B.; Bielewicz, P.; Bock, J. J.; Bonavera, L.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Boulanger, F.; Bucher, M.; Burigana, C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chary, R.-R.; Chiang, H. C.; Christensen, P. R.; Clements, D. L.; Colombi, S.; Colombo, L. P. L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; Davis, R. J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T. A.; Eriksen, H. K.; Falgarone, E.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A. A.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Ghosh, T.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K. M.; Gratton, S.; Gruppuso, A.; Gudmundsson, J. E.; Hansen, F. K.; Hanson, D.; Harrison, D. L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Hornstrup, A.; Hovest, W.; Huffenberger, K. M.; Hurier, G.; Jaffe, A. H.; Jaffe, T. R.; Jones, W. C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T. S.; Kneissl, R.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C. R.; Le Jeune, M.; Leahy, J. P.; Lellouch, E.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P. M.; Macías-Pérez, J. F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P. G.; Martínez-González, E.; Masi, S.; Matarrese, S.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Moreno, R.; Morgante, G.; Mortlock, D.; Moss, A.; Mottet, S.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; Noviello, F.; Novikov, D.; Novikov, I.; Oxborrow, C. A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Pearson, T. J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Pratt, G. W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Renzi, A.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savelainen, M.; Savini, G.; Scott, D.; Seiffert, M. D.; Shellard, E. P. S.; Spencer, L. D.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Wade, L. A.; Wandelt, B. D.; Watson, R.; Wehus, I. K.; Yvon, D.; Zacchei, A.; Zonca, A.
2016-09-01
The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full mission TOI is included in the Planck 2015 release. This paper describes the HFI TOI and beam processing for the 2015 release. HFI calibration and map making are described in a companion paper. The main pipeline has been modified since the last release (2013 nominal mission in intensity only), by including a correction for the nonlinearity of the warm readout and by improving the model of the bolometer time response. The beam processing is an essential tool that derives the angular response used in all the Planck science papers and we report an improvement in the effective beam window function uncertainty of more than a factor of 10 relative to the2013 release. Noise correlations introduced by pipeline filtering function are assessed using dedicated simulations. Angular cross-power spectra using data sets that are decorrelated in time are immune to the main systematic effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adam, R.; Ade, P. A. R.; Aghanim, N.
The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full mission TOI is included in the Planck 2015 release. This study describes the HFI TOI and beam processing for the 2015 release. HFI calibration and map making are described in a companion paper. The mainmore » pipeline has been modified since the last release (2013 nominal mission in intensity only), by including a correction for the nonlinearity of the warm readout and by improving the model of the bolometer time response. The beam processing is an essential tool that derives the angular response used in all the Planck science papers and we report an improvement in the effective beam window function uncertainty of more than a factor of 10 relative to the2013 release. Noise correlations introduced by pipeline filtering function are assessed using dedicated simulations. Finally, angular cross-power spectra using data sets that are decorrelated in time are immune to the main systematic effects.« less
Manipulating neural activity in physiologically classified neurons: triumphs and challenges
Gore, Felicity; Schwartz, Edmund C.; Salzman, C. Daniel
2015-01-01
Understanding brain function requires knowing both how neural activity encodes information and how this activity generates appropriate responses. Electrophysiological, imaging and immediate early gene immunostaining studies have been instrumental in identifying and characterizing neurons that respond to different sensory stimuli, events and motor actions. Here we highlight approaches that have manipulated the activity of physiologically classified neurons to determine their role in the generation of behavioural responses. Previous experiments have often exploited the functional architecture observed in many cortical areas, where clusters of neurons share response properties. However, many brain structures do not exhibit such functional architecture. Instead, neurons with different response properties are anatomically intermingled. Emerging genetic approaches have enabled the identification and manipulation of neurons that respond to specific stimuli despite the lack of discernable anatomical organization. These approaches have advanced understanding of the circuits mediating sensory perception, learning and memory, and the generation of behavioural responses by providing causal evidence linking neural response properties to appropriate behavioural output. However, significant challenges remain for understanding cognitive processes that are probably mediated by neurons with more complex physiological response properties. Currently available strategies may prove inadequate for determining how activity in these neurons is causally related to cognitive behaviour. PMID:26240431
McNamee, J E; Lipman, E L; Hicks, F
1995-09-01
To provide a preliminary report of data from 2 support groups for single mothers, all of whom were mothers of children attending a child outpatient psychiatric clinic. The groups' 2 purposes were: 1. to assess the feasibility of adding structured evaluation to a common clinical intervention; 2. to improve single mothers' parenting skills through raised levels of self-esteem, increased capacity for family functioning and reduced levels of depression. Three structured evaluation instruments were used to measure the domains of self-esteem, family functioning and depression. These instruments were given to both groups of women on 3 occasions: 1. before the group; 2. after the group; 3. at a follow-up session 4 months after group termination. Open-ended questions were also asked at group termination. The questionnaire response rate was 100%; overall response rate for the 3 open-ended questions was 89%. Comparisons of pre-group and post-group scores showed that there was a significant increase in self-esteem (p < 0.01) and significant improvements in family functioning (p < 0.05) and depression (p < 0.01). It is possible to introduce a structured evaluation component into a common clinical intervention, and this support group seemed to assist single mothers' parenting skills. Methodologic concerns and future directions are discussed.
Condensation nuclei measurement in the stratosphere for the NASA ACE program
NASA Astrophysics Data System (ADS)
Wilson, James Charles
1994-11-01
A condensation nucleus counter which operated at stratospheric pressures was developed, designed, and constructed. It was calibrated in the laboratory. Its response as a function of particle size and concentration was reported. This was the first time that the response of such an instrument was verified in the laboratory. An inlet was constructed which provided near isokinetic sampling. The resulting instrument, the U-2 CNC, was deployed on NASA U-2 aircraft in the study of the climatic effects of aerosol. These studies occurred in March, April, May, July, November, and December of 1992 and in April, May, June, and December of 1983. The U-2 CNC was used in the study of the aerosol cloud resulting from the eruption of El Chichon. It permitted the observation of new particle formation in the stratosphere.
Condensation nuclei measurement in the stratosphere for the NASA ACE program
NASA Technical Reports Server (NTRS)
Wilson, James Charles
1994-01-01
A condensation nucleus counter which operated at stratospheric pressures was developed, designed, and constructed. It was calibrated in the laboratory. Its response as a function of particle size and concentration was reported. This was the first time that the response of such an instrument was verified in the laboratory. An inlet was constructed which provided near isokinetic sampling. The resulting instrument, the U-2 CNC, was deployed on NASA U-2 aircraft in the study of the climatic effects of aerosol. These studies occurred in March, April, May, July, November, and December of 1992 and in April, May, June, and December of 1983. The U-2 CNC was used in the study of the aerosol cloud resulting from the eruption of El Chichon. It permitted the observation of new particle formation in the stratosphere.
Agile Mcal, the Mini-Calorimeter
NASA Astrophysics Data System (ADS)
Bastia, Paolo; Poulsen, Jens Michael; Monzani, Franco; Radaelli, Paolo; Marchesi, Paolo; Labanti, Claudio; Marisaldi, Martino; Fuschino, Fabio; Bulgarelli, Andrea
2006-04-01
AGILE is a scientific mission dedicated to gamma-ray astrophysics in space, and the mini-calorimeter MCAL is one of four detector systems on the satellite. The MCAL instrument is sensitive in the energy range: 300 keV - 100 MeV. It has two main functions: one autonomous mode for detection of impulsive cosmic events and the other as “a slave” supporting the energy measurements of the pair-conversion tracker. The AGILE Small Mission is funded by the Italian Space Agency (ASI), and the INAF-IASF section at Bologna has the scientific responsibility for MCAL. LABEN develops the MCAL instrument with its detectors and electronics. This paper gives an overview of the detectors on AGILE, and then it gives details on the design of MCAL, and finally we report on the tests at instrument level.
NASA Technical Reports Server (NTRS)
Smith, Craig K.; Kim, Edward; Leslie, R. Vincent; Lyu, Joseph; McCormick, Lisa M.; Anderson, Kent
2017-01-01
The Advanced Technology Microwave Sounder (ATMS) is a space-based, cross-track radiometer for operational atmospheric temperature and humidity sounding, utilizing 22 channels over a frequency range from 23 to 183 gigahertz. The ATMS for the Joint Polar Satellite System-1 has undergone two rounds of re-work in 2014-2015 and 2016, following performance issues discovered during and following thermal vacuum chamber (TVAC) testing at the instrument and observatory level. Final shelf-level testing, including measurement of pass band characteristics and spectral response functions, was completed in December 2016. Final instrument-level TVAC testing and calibration occurred during February 2017. Here we will describe the instrument-level TVAC calibration process, and illustrate with results from the final TVAC calibration effort.
Evaluation of a noninvasive method for monitoring percutaneous absorption of lidocaine in vivo.
Kushla, G P; Zatz, J L
1990-10-01
The pharmacodynamic measurement of in vivo skin penetration of lidocaine was explored with an instrument used in dentistry to determine tooth pulp vitality. The instrument delivers a low-current, pulsatile electrical waveform of increasing intensity with time. The readings, which are reproducible, are in arbitrary units on a scale of 0-80. Testing of naive sites showed variation as a function of location, even over relatively small distances. The response at a marked site over a 12-hr period generally was consistent in five subjects. Following intradermal administration of 1 or 2% lidocaine hydrochloride injection in one subject, the instrument reached its maximum value within 2 min. This was followed by a sustained plateau and then a gradual falloff of the effect. Topical formulations containing 5% lidocaine base and corresponding blank formulations were applied under occlusion within Hilltop chambers to intact skin on the forearms of human volunteers for 3 hr. While the response to a 40% propylene glycol formulation was not significantly different from the corresponding control, a cream exhibited slow development of profound anesthesia that lasted for several hours following chamber removal.
1980-02-19
instrumental in the initiation of the "Thousand Aviator Study" and particu- larly to those responsible for the 1963-1965 follow-up. Without the work...in a person’s response to noise exposure. Because of the obvious value of a valid, reliable, and easy-to-administer test of individual noise...their cardio- vascular functioning through physical exercise . And Willson, Chung, Gannon, Roberts, and Mason (29), addressing ths oame general question
Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsen, A. S., E-mail: Ajsen@fysik.dtu.dk; Salewski, M.; Korsholm, S. B.
2014-11-15
The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR.
Detection of low-amplitude in vivo intrinsic signals from an optical imager of retinal function
NASA Astrophysics Data System (ADS)
Barriga, Eduardo S.; T'so, Dan; Pattichis, Marios; Kwon, Young; Kardon, Randy; Abramoff, Michael; Soliz, Peter
2006-02-01
In the early stages of some retinal diseases, such as glaucoma, loss of retinal activity may be difficult to detect with today's clinical instruments. Many of today's instruments focus on detecting changes in anatomical structures, such as the nerve fiber layer. Our device, which is based on a modified fundus camera, seeks to detect changes in optical signals that reflect functional changes in the retina. The functional imager uses a patterned stimulus at wavelength of 535nm. An intrinsic functional signal is collected at a near infrared wavelength. Measured changes in reflectance in response to the visual stimulus are on the order of 0.1% to 1% of the total reflected intensity level, which makes the functional signal difficult to detect by standard methods because it is masked by other physiological signals and by imaging system noise. In this paper, we analyze the video sequences from a set of 60 experiments with different patterned stimuli from cats. Using a set of statistical techniques known as Independent Component Analysis (ICA), we estimate the signals present in the videos. Through controlled simulation experiments, we quantify the limits of signal strength in order to detect the physiological signal of interest. The results of the analysis show that, in principle, signal levels of 0.1% (-30dB) can be detected. The study found that in 86% of the animal experiments the patterned stimuli effects on the retina can be detected and extracted. The analysis of the different responses extracted from the videos can give an insight of the functional processes present during the stimulation of the retina.
Kounali, Daphne Z; Button, Katherine S; Lewis, Glyn; Ades, Anthony E
2016-09-01
We present a meta-analytic method that combines information on treatment effects from different instruments from a network of randomized trials to estimate instrument relative responsiveness. Five depression-test instruments [Beck Depression Inventory (BDI I/II), Patient Health Questionnaire (PHQ9), Hamilton Rating for Depression 17 and 24 items, Montgomery-Asberg Depression Rating] and three generic quality of life measures [EuroQoL (EQ-5D), SF36 mental component summary (SF36 MCS), and physical component summary (SF36 PCS)] were compared. Randomized trials of treatments for depression reporting outcomes on any two or more of these instruments were identified. Information on the within-trial ratios of standardized treatment effects was pooled across the studies to estimate relative responsiveness. The between-instrument ratios of standardized treatment effects vary across trials, with a coefficient of variation of 13% (95% credible interval: 6%, 25%). There were important differences between the depression measures, with PHQ9 being the most responsive instrument and BDI the least. Responsiveness of the EQ-5D and SF36 PCS was poor. SF36 MCS performed similarly to depression instruments. Information on relative responsiveness of several test instruments can be pooled across networks of trials reporting at least two outcomes, allowing comparison and ranking of test instruments that may never have been compared directly. Copyright © 2016 Elsevier Inc. All rights reserved.
Nieuwesteeg, Anke; Hartman, Esther; Pouwer, Frans; Emons, Wilco; Aanstoot, Henk-Jan; Van Mil, Edgar; Van Bakel, Hedwig
2014-06-10
In young children with type 1 diabetes mellitus (T1DM), parents have complete responsibility for the diabetes-management. In toddlers and (pre)schoolers, the tasks needed to achieve optimal blood glucose control may interfere with normal developmental processes and could negatively affect the quality of parent-child interaction. Several observational instruments are available to measure the quality of the parent-child interaction. However, no observational instrument for diabetes-specific situations is available. Therefore, the aim of the present study was to develop a qualitative observation instrument, to be able to assess parent-child interaction during diabetes-specific situations. First, in a pilot study (n = 15), the observation instrument was developed in four steps: (a) defining relevant diabetes-specific situations; (b) videotaping these situations; (c) describing all behaviors in a qualitative observation instrument; (d) evaluating usability and reliability. Next, we examined preliminary validity (total n = 77) by testing hypotheses about correlations between the observation instrument for diabetes-specific situations, a generic observation instrument and a behavioral questionnaire. The observation instrument to assess parent-child interaction during diabetes-specific situations, which consists of ten domains: "emotional involvement", "limit setting", "respect for autonomy", "quality of instruction", "negative behavior", "avoidance", "cooperative behavior", "child's response to injection", "emphasis on diabetes", and "mealtime structure", was developed for use during a mealtime situation (including glucose monitoring and insulin administration). The present study showed encouraging indications for the usability and inter-rater reliability (weighted kappa was 0.73) of the qualitative observation instrument. Furthermore, promising indications for the preliminary validity of the observation instrument for diabetes-specific situations were found (r ranged between |.24| and |.45| for significant correlations and between |.10| and |.23| for non-significant trends). This observation instrument could be used in future research to (a) test whether parent-child interactions are associated with outcomes (like HbA1c levels and psychosocial functioning), and (b) evaluate interventions, aimed at optimizing the quality of parent-child interactions in families with a young child with T1DM.
NASA Technical Reports Server (NTRS)
Liang, Steven Y.; Dornfeld, David A.; Nickerson, Jackson A.
1987-01-01
The coloring effect on the acoustic emission signal due to the frequency response of the data acquisition/processing instrumentation may bias the interpretation of AE signal characteristics. In this paper, a frequency domain deconvolution technique, which involves the identification of the instrumentation transfer functions and multiplication of the AE signal spectrum by the inverse of these system functions, has been carried out. In this way, the change in AE signal characteristics can be better interpreted as the result of the change in only the states of the process. Punch stretching process was used as an example to demonstrate the application of the technique. Results showed that, through the deconvolution, the frequency characteristics of AE signals generated during the stretching became more distinctive and can be more effectively used as tools for process monitoring.
Rêgo Segundo, Alan Kardek; Martins, José Helvecio; Monteiro, Paulo Marcos de Barros; de Oliveira, Rubens Alves; Freitas, Gustavo Medeiros
2015-10-05
The scarcity of drinking water affects various regions of the planet. Although climate change is responsible for the water availability, humanity plays an important role in preserving this precious natural resource. In case of negligence, the likely trend is to increase the demand and the depletion of water resources due to the increasing world population. This paper addresses the development, design and construction of a low cost system for measuring soil volumetric water content (θ), electrical conductivity (σ) and temperature (T), in order to optimize the use of water, energy and fertilizer in food production. Different from the existing measurement instruments commonly deployed in these applications, the proposed system uses an auto-balancing bridge circuit as measurement method. The proposed models to estimate θ and σ and correct them in function of T are compared to the ones reported in literature. The final prototype corresponds to a simple circuit connected to a pair of electrode probes, and presents high accuracy, high signal to noise ratio, fast response, and immunity to stray capacitance. The instrument calibration is based on salt solutions with known dielectric constant and electrical conductivity as reference. Experiments measuring clay and sandy soils demonstrate the satisfactory performance of the instrument.
Kertesz, Stefan. G.; Pollio, David E.; Jones, Richard N.; Steward, Jocelyn; Stringfellow, Erin J.; Gordon, Adam J.; Johnson, Nancy K.; Kim, Theresa A.; Granstaff, Unita; Austin, Erika L.; Young, Alexander S.; Golden, Joya; Davis, Lori L.; Roth, David L.; Holt, Cheryl L.
2015-01-01
Background Homeless patients face unique challenges in obtaining primary care responsive to their needs and context. Patient experience questionnaires could permit assessment of patient-centered medical homes for this population, but standard instruments may not reflect homeless patients' priorities and concerns. Objectives This report describes (a) the content and psychometric properties of a new primary care questionnaire for homeless patients and (b) the methods utilized in its development. Methods Starting with quality-related constructs from the Institute of Medicine, we identified relevant themes by interviewing homeless patients and experts in their care. A multidisciplinary team drafted a preliminary set of 78 items. This was administered to homeless-experienced clients (n=563) across 3 VA facilities and 1 non-VA Health Care for the Homeless Program. Using Item Response Theory, we examined Test Information Function curves to eliminate less informative items and devise plausibly distinct subscales. Results The resulting 33-item instrument (Primary Care Quality-Homeless, PCQ-H) has four subscales: Patient-Clinician Relationship (15 items), Cooperation among Clinicians (3 items), Access/Coordination (11 items) and Homeless-Specific Needs (4 items). Evidence for divergent and convergent validity is provided. Test Information Function (TIF) graphs showed adequate informational value to permit inferences about groups for 3 subscales (Relationship, Cooperation and Access/Coordination). The 3-item Cooperation subscale had lower informational value (TIF<5) but had good internal consistency (alpha=0.75) and patients frequently reported problems in this aspect of care. Conclusions Systematic application of qualitative and quantitative methods supported the development of a brief patient-reported questionnaire focused on the primary care of homeless patients and offers guidance for future population-specific instrument development. PMID:25023918
Tadić, Valerija; Cooper, Andrew; Cumberland, Phillippa; Lewando-Hundt, Gillian; Rahi, Jugnoo S
2013-12-01
To develop a novel age-appropriate measure of functional vision (FV) for self-reporting by visually impaired (VI) children and young people. Questionnaire development. A representative patient sample of VI children and young people aged 10 to 15 years, visual acuity of the logarithm of the minimum angle of resolution (logMAR) worse than 0.48, and a school-based (nonrandom) expert group sample of VI students aged 12 to 17 years. A total of 32 qualitative semistructured interviews supplemented by narrative feedback from 15 eligible VI children and young people were used to generate draft instrument items. Seventeen VI students were consulted individually on item relevance and comprehensibility, instrument instructions, format, and administration methods. The resulting draft instrument was piloted with 101 VI children and young people comprising a nationally representative sample, drawn from 21 hospitals in the United Kingdom. Initial item reduction was informed by presence of missing data and individual item response pattern. Exploratory factor analysis (FA) and parallel analysis (PA), and Rasch analysis (RA) were applied to test the instrument's psychometric properties. Psychometric indices and validity assessment of the Functional Vision Questionnaire for Children and Young People (FVQ_CYP). A total of 712 qualitative statements became a 56-item draft scale, capturing the level of difficulty in performing vision-dependent activities. After piloting, items were removed iteratively as follows: 11 for high percentage of missing data, 4 for skewness, and 1 for inadequate item infit and outfit values in RA, 3 having shown differential item functioning across age groups and 1 across gender in RA. The remaining 36 items showed item fit values within acceptable limits, good measurement precision and targeting, and ordered response categories. The reduced scale has a clear unidimensional structure, with all items having a high factor loading on the single factor in FA and PA. The summary scores correlated significantly with visual acuity. We have developed a novel, psychometrically robust self-report questionnaire for children and young people-the FVQ_CYP-that captures the functional impact of visual disability from their perspective. The 36-item, 4-point unidimensional scale has potential as a complementary adjunct to objective clinical assessments in routine pediatric ophthalmology practice and in research. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farawila, Y.; Gohar, Y.; Maynard, C.
1989-04-01
KAOS/LIB-V: A library of processed nuclear responses for neutronics analyses of nuclear systems has been generated. The library was prepared using the KAOS-V code and nuclear data from ENDF/B-V. The library includes kerma (kinetic energy released in materials) factors and other nuclear response functions for all materials presently of interest in fusion and fission applications for 43 nonfissionable and 15 fissionable isotopes and elements. The nuclear response functions include gas production and tritium-breeding functions, and all important reaction cross sections. KAOS/LIB-V employs the VITAMIN-E weighting function and energy group structure of 174 neutron groups. Auxiliary nuclear data bases, e.g., themore » Japanese evaluated nuclear data library JENDL-2 were used as a source of isotopic cross sections when these data are not provided in ENDF/B-V files for a natural element. These are needed mainly to estimate average quantities such as effective Q-values for the natural element. This analysis of local energy deposition was instrumental in detecting and understanding energy balance deficiencies and other problems in the ENDF/B-V data. Pertinent information about the library and a graphical display of the main nuclear response functions for all materials in the library are given. 35 refs.« less
Incorporating Data Link Messaging into a Multi-function Display for General Aviation Aircraft
NASA Technical Reports Server (NTRS)
Adams, Catherine A.; Murdoch, Jennifer L.
2006-01-01
One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness over conventional instrument flight rules (IFR) procedures.
ERIC Educational Resources Information Center
Mulligan, Marilyn
The underlying theme of this review is that fine motor assessment for skills acquired during the first year of life includes a description of the coordination of reach and grasp behaviors into functional understanding, purposeful retention of an object, and manipulatian. The developmental sequence of these responses is listed in various…
Measuring Social Well-Being in People with Chronic Illness
ERIC Educational Resources Information Center
Hahn, Elizabeth A.; Cella, David; Bode, Rita K.; Hanrahan, Rachel T.
2010-01-01
Although social well-being (SWB) is recognized as an integral component of health, it is rarely included in health-related quality of life (HRQL) instruments. Two SWB dimensions were identified by literature review: social support (SWB-SS) and social function (SWB-SF). As part of a larger project to develop item response theory-derived item banks…
Seismic instrumentation of buildings
Çelebi, Mehmet
2000-01-01
The purpose of this report is to provide information on how and why we deploy seismic instruments in and around building structures. The recorded response data from buildings and other instrumented structures can be and are being primarily used to facilitate necessary studies to improve building codes and therefore reduce losses of life and property during damaging earthquakes. Other uses of such data can be in emergency response situations in large urban environments. The report discusses typical instrumentation schemes, existing instrumentation programs, the steps generally followed in instrumenting a structure, selection and type of instruments, installation and maintenance requirements and data retrieval and processing issues. In addition, a summary section on how recorded response data have been utilized is included. The benefits from instrumentation of structural systems are discussed.
Rodríguez-Vidal, Arturo; Martínez-Flores, Héctor Eduardo; González Jasso, Eva; Velázquez de la Cruz, Gonzalo; Ramírez-Jiménez, Aurea K; Morales-Sánchez, Eduardo
2017-06-01
The quality of extruded snacks can be affected not only by processing conditions, but also by some factors like the concentration and type of ingredients incorporated in their formulation and the working conditions used. Although the process conditions have been established with measurable textural properties, sensory qualities have not been correlated with these responses in expanded extruded snacks made with added functional ingredients. Therefore, in this study the effect of adding textured soy flour (TSF) and whole wheat flour (WWF) to refined wheat flour in the production of extruded snacks and expanded with hot air was evaluated. A response surface design using two levels with five central points was applied to obtain the best combinations of functional ingredients added, holding the parameters of the extrusion process and moisture of treatments. Some texture characteristics and sensory analysis were used as response variables, such as, hardness, fracturability, toughness, crispness, granularity, and chewiness. Likewise, the rate of expansion was evaluated. The results showed that the level of substitution of WWF, especially levels of 15%, had a significant effect on the hardness perceived by the panelist during sensory evaluation. The TSF at concentrations of ≥15%, favored the fracturability and crispness of the samples. It was found that the best expansion index was with the combination of 5% TSF and 15% WWF. Although a correlation between instrumental and sensory tests carried out on the extruded snacks expanded was not found. The physical characteristics of the extruded snacks such as expansion, hardness, and density are important parameters in terms of consumer acceptability of the final product as well as their functional properties. In other words, the appearance and texture are two of the most important attributes that can be seen in snack foods. In particular, the texture can be measured by intrinsic tests: objective (instrumental) and subjective (sensory). That is because the instrumental analysis provides parameters such as firmness, brittleness, consistency, chewiness, among others, when subjected to different stress, strain, and strain rates at the snacks. Similarly, sensory analysis, allows us to see features that include mechanical attributes (concerning the reaction to the applied force), geometric attributes (concerning the shape, size, and orientation of the particles within the food), and attributes related to the perception of moisture or fat content. © 2016 Wiley Periodicals, Inc.
Research concerning the net flux of radiation in the atmosphere of Jupiter
NASA Technical Reports Server (NTRS)
Tomasko, M. G.
1996-01-01
The plan of the NFR (Net Flux of Radiation) team is for the data from the two solar channels (B and E) of NFR to be reduced with the goal of determining the solar heating rate. In order to determine the solar heating rate from the NFR measurements, effects due to the instrument's spatial and spectral response functions, to the temperature variation of the instrument (and associated drift of calibration), to the setting sun, and to the rotation of the probe (initially at a rate comparable to the NFR sampling frequency), all must be well modelled. In the past year, a forward modeling routine was created to simulate NFR data return in the B and E channels. The effects of varying parameters describing the atmospheric model (such as cloud location and thickness) and the descent profile (such as rotation rate) were investigated and an inversion routine was developed. For the forward modeling, existing radiative transfer codes were used to determine intensity fields within the Jovian atmosphere. A routine was developed to determine instantaneous instrument response by integrating the intensity field over the instrument response functions. A second routine was developed to determine the actual output of the NFR by integrating along an arbitrary descent trajectory. Near the top of the atmosphere, the upflux data alone are used to constrain the cloud structure of he atmosphere. To accomplish this, models are used to describe the variation in up flux between consecutive measurements in terms of variations of cloud opacity and variations in known parameters such as the solar zenith angle. This allows us to develop a zero-order model of cloud structure. Lower in the atmosphere, at levels where there is little or no azimuthal structure to the net flux measurements, both the up flux and net flux are used to derive layer transmission and reflection functions, which then determine layer opacity and single scattering albedo. A preliminary analysis of the data began in December 1995. In these data we could see the rapid oscillations expected at the beginning of the data due to probe rotation and the sun passing through the edge of the field of view. In addition, the time when this oscillation stopped was clearly visible. This sets the rough optical depth above the probe at this time.
Intercalibration between HIRS/2 and HIRS/3 channel 12 based on physical considerations
NASA Astrophysics Data System (ADS)
Gierens, Klaus; Eleftheratos, Kostas; Sausen, Robert
2018-02-01
High-resolution Infrared Radiation Sounder (HIRS) brightness temperatures at channel 12 (T12) can be used to assess the water vapour content of the upper troposphere. The transition from HIRS/2 to HIRS/3 in 1999 involved a shift in the central wavelength of channel 12 from 6.7 to 6.5 µm, causing a discontinuity in the time series of T12. To understand the impact of this change in the measured brightness temperatures, we have performed radiative transfer calculations for channel 12 of HIRS/2 and HIRS/3 instruments, using a large set of radiosonde profiles of temperature and relative humidity from three different sites. Other possible changes within the instrument, apart from the changed spectral response function, have been assumed to be of minor importance, and in fact, it was necessary to assume as a working hypothesis that the spectral and radiometric calibration of the two instruments did not change during the relatively short period of their common operation. For each radiosonde profile we performed two radiative transfer calculations, one using the HIRS/2 channel response function of NOAA 14 and one using the HIRS/3 channel response function of NOAA 15, resulting in negative differences of T12 (denoted as ΔT12 := T12/15 - T12/14) ranging between -12 and -2 K. Inspection of individual profiles for large, medium and small values of ΔT12 pointed to the role of the mid-tropospheric humidity. This guided us to investigate the relation between ΔT12 and the channel 11 brightness temperatures which are typically used to detect signals from the mid-troposphere. This allowed us to construct a correction for the HIRS/3 T12, which leads to a pseudo-channel 12 brightness temperature as if a HIRS/2 instrument had measured it. By applying this correction we find an excellent agreement between the original HIRS/2 T12 and the HIRS/3 data inferred from the correction method with R = 0.986. Upper-tropospheric humidity (UTH) derived from the pseudo HIRS/2 T12 data compared well with that calculated from intersatellite-calibrated data, providing independent justification for using the two intercalibrated time series (HIRS/2 and HIRS/3) as a continuous HIRS time series for long-term UTH analyses.
Building Quakes: Detection of Weld Fractures in Buildings using High-Frequency Seismic Techniques
NASA Astrophysics Data System (ADS)
Heckman, V.; Kohler, M. D.; Heaton, T. H.
2009-12-01
Catastrophic fracture of welded beam-column connections in buildings was observed in the Northridge and Kobe earthquakes. Despite the structural importance of such connections, it can be difficult to locate damage in structural members underneath superficial building features. We have developed a novel technique to locate fracturing welds in buildings in real time using high-frequency information from seismograms. Numerical and experimental methods were used to investigate an approach for detecting the brittle fracture of welds of beam-column connections in instrumented steel moment-frame buildings through the use of time-reversed Green’s functions and wave propagation reciprocity. The approach makes use of a prerecorded catalogue of Green’s functions for an instrumented building to detect high-frequency failure events in the building during a later earthquake by screening continuous data for the presence of one or more of the events. This was explored experimentally by comparing structural responses of a small-scale laboratory structure under a variety of loading conditions. Experimentation was conducted on a polyvinyl chloride frame model structure with data recorded at a sample rate of 2000 Hz using piezoelectric accelerometers and a 24-bit digitizer. Green’s functions were obtained by applying impulsive force loads at various locations along the structure with a rubber-tipped force transducer hammer. We performed a blind test using cross-correlation techniques to determine if it was possible to use the catalogue of Green’s functions to pinpoint the absolute times and locations of subsequent, induced failure events in the structure. A finite-element method was used to simulate the response of the model structure to various source mechanisms in order to determine the types of elastic waves that were produced as well as to obtain a general understanding of the structural response to localized loading and fracture.
Lao-Kaim, Nick P; Fonville, Leon; Giampietro, Vincent P; Williams, Steven C R; Simmons, Andrew; Tchanturia, Kate
2015-01-01
People with Anorexia Nervosa exhibit difficulties flexibly adjusting behaviour in response to environmental changes. This has previously been attributed to problematic behavioural shifting, characterised by a decrease in fronto-striatal activity. Additionally, alterations of instrumental learning, which relies on fronto-striatal networks, may contribute to the observation of inflexible behaviour. The authors sought to investigate the neural correlates of cognitive flexibility and learning in Anorexia Nervosa. Thirty-two adult females with Anorexia Nervosa and thirty-two age-matched female control participants completed the Wisconsin Card Sorting Task whilst undergoing functional magnetic resonance imaging. Event-related analysis permitted the comparison of cognitive shift trials against those requiring maintenance of rule-sets and allowed assessment of trials representing learning. Although both groups performed similarly, we found significant interactions in the left middle frontal gyrus, precuneus and superior parietal lobule whereby blood-oxygenated-level dependent response was higher in Anorexia Nervosa patients during shifting but lower when maintaining rule-sets, as compared to healthy controls. During learning, posterior cingulate cortex activity in healthy controls decreased whilst increasing in the Anorexia Nervosa group, whereas the right precuneus exhibited the opposite pattern. Furthermore, learning was associated with lower blood-oxygenated-level dependent response in the caudate body, as compared to healthy controls. People with Anorexia Nervosa display widespread changes in executive function. Whilst cognitive flexibility appears to be associated with aberrant functioning of the fronto-parietal control network that mediates between internally and externally directed cognition, fronto-striatal alterations, particularly within the caudate body, were associated with instrumental learning. Together, this shows how perseverative tendencies could be a substrate of multiple high-order processes that may contribute to the maintenance of Anorexia Nervosa.
Oude Voshaar, Martijn A H; Ten Klooster, Peter M; Glas, Cees A W; Vonkeman, Harald E; Taal, Erik; Krishnan, Eswar; Bernelot Moens, Hein J; Boers, Maarten; Terwee, Caroline B; van Riel, Piet L C M; van de Laar, Mart A F J
2015-12-01
To evaluate the content validity and measurement properties of the Patient-Reported Outcome Measurement Information System (PROMIS) physical function item bank and a 20-item short form in patients with RA in comparison with the HAQ disability index (HAQ-DI) and 36-item Short Form Health Survey (SF-36) physical functioning scale (PF-10). The content validity of the instruments was evaluated by linking their items to the International Classification of Functioning, Disability and Health (ICF) core set for RA. The measures were administered to 690 RA patients enrolled in the Dutch Rheumatoid Arthritis Monitoring registry. Measurement precision was evaluated using item response theory methods and construct validity was evaluated by correlating physical function scores with other clinical and patient-reported outcome measures. All 207 health concepts identified in the physical function measures referred to activities that are featured in the ICF. Twenty-three of 26 ICF RA core set domains are featured in the full PROMIS physical function item bank compared with 13 and 8 for the HAQ-DI and PF-10, respectively. As hypothesized, all three physical function instruments were highly intercorrelated (r 0.74-0.84), moderately correlated with disease activity measures (r 0.44-0.63) and weakly correlated with age (rs 0.07-0.14). Item response theory-based analysis revealed that a 20-item PROMIS physical function short form covered a wider range of physical function levels than the HAQ-DI or PF-10. The PROMIS physical function item bank demonstrated excellent measurement properties in RA. A content-driven 20-item short form may be a useful tool for assessing physical function in RA. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Sakschewski, Mark; Eggert, Sabina; Schneider, Susanne; Bögeholz, Susanne
2014-09-01
The concept of energy is one key component of science education curricula worldwide. While it is still being taught in many science classrooms from a mainly conceptual knowledge perspective, the need to frame the concept of energy as a socioscientific issue and implement it in the context of citizenship education and education for sustainable development, is getting more and more explicit. As we will be faced with limited fossil fuels and the consequences of global climate change in the future, students have to be supported in becoming literate citizens who are able to reach informed energy-related decisions. In this article, we focus on students' reasoning and decision-making processes about socioscientific energy-related issues. In more detail, we developed a paper-and-pencil measurement instrument to assess secondary school students' competencies in this domain. The functioning of the measurement instrument was analysed with a sample of 850 students from grades 6, 8, 10 and 12 using item response theory. Findings show that the measurement instrument functions in terms of reliability and validity. Concerning student ability, elaborate reasoning and decision-making was characterised by the use of trade-offs and the ability to weigh arguments and to reflect on the structure of reasoning and decision-making processes. The developed measurement instrument provides a complement for existing test instruments on conceptual knowledge about the concept of energy. It aims to contribute to a change in teaching about energy, especially in physics education in the sense of education for sustainable development.
Angst, Felix; Verra, Martin L; Lehmann, Susanne; Gysi, Françoise; Benz, Thomas; Aeschlimann, André
2012-02-01
To determine and compare the sensitivity to change of the condition-specific cervical Northern American Spine Society (NASS) and the generic Short Form 36 (SF-36). Prospective cohort study. One hundred and seventy five patients after whiplash injury. Four-week inpatient interdisciplinary pain management programme. MAIN MEASURES, ANALYSIS: Responsiveness of the NASS and the SF-36 was quantified by effect size and standardized response mean and compared within the same construct by the modified Jacknife test. Ability to detect improvement was compared using sensitivities determined from receiver operating characteristics curves. In pain, the NASS was comparable responsive to the SF-36 at the one-month follow-up (n = 175): effect sizes: 0.62 (NASS) versus 0.61 (SF-36), P = 0.914. The NASS was less responsive than the SF-36 in function: 0.23 versus 0.63, P < 0.001 and in pain+function: 0.35 versus 0.58 (P = 0.001). These relationships remained consistent using standardized response means, at the six-month follow-up (n = 103), and in the comparison of the sensitivities. Sensitivities at one month, pain: 70% (NASS) versus 62% (SF-36), P = 0.234; function: 65% versus 80%, P = 0.002; pain+function: 68% versus 78%, P = 0.035. The six-month data were similar. The generic SF-36 was more responsive in function and equally responsive in pain when compared to the condition-specific NASS. The SF-36 can be recommended as a responsive instrument for measurement of pain and function in chronic whiplash syndrome.
Lugo, Josefina; Nápoles, Misleidy; Pérez, Inés; Ordaz, Niurka; Luzardo, Mario; Fernández, Leticia
2014-01-01
INTRODUCTION Although modern technology has extended the survival of breast cancer patients, treatment's adverse effects impact their health-related quality of life. Currently, no instrument exists capable of identifying the range of problems affecting breast cancer patients receiving radiotherapy in Cuba's socioeconomic and cultural context. OBJECTIVES Construct and validate an instrument to measure the effects of breast cancer and radiotherapy on health-related quality of life in Cuban patients. METHODS The study was conducted at the Oncology and Radiobiology Institute, Havana, Cuba, from January 2010 through December 2011. Inclusion criteria were: adult female, histological diagnosis of breast cancer, treated with ambulatory radiotherapy, and written informed consent; patients unable to communicate orally or in writing, or who had neurologic or psychiatric conditions were excluded. Development phase: focus groups guided by a list of questions were carried out with 50 women. The patients reported 61 problems affecting their health-related quality-of-life. A nominal group (six oncologists and two nurses) identified the same problems. A syntactic analysis of the information was performed to create items for study and measurement scales. Content validity was determined by a nominal group of seven experts using professional judgment. Another 20 patients were selected to evaluate face validity. Validation phase: the instrument was applied to 230 patients at three different points: before radiotherapy, at the end of radiotherapy and four weeks after radiotherapy was concluded. Reliability, construct validity, discriminant validity, predictive validity, interpretability and response burden were evaluated. RESULTS The final instrument developed had 33 items distributed in 4 domains: physical functioning, psychological functioning, social and family relationships, and physical and emotional adverse effects of disease and treatment. There were two discrete items: perceived general health and perceived health-related quality of life. Content validity and face validity were assessed as acceptable, by experts and patients respectively. Homogeneity, construct validity, and discriminant validity were satisfactory. The best results were obtained with test-retest reliability, predictive validity, and interpretability; the low rate of unanswered questions indicated that the instrument did not produce excessive patient response burden. CONCLUSION The new instrument fulfilled the requirements for measuring impact of breast cancer and of radiotherapy on health-related quality of life in these Cuban patients, validating its usefulness for inclusion in clinical trial protocols.
Kelley, Daniel J; Johnson, Sterling C
2007-01-01
Background With rapid advances in functional imaging methods, human studies that feature functional neuroimaging techniques are increasing exponentially and have opened a vast arena of new possibilities for understanding brain function and improving the care of patients with cognitive disorders in the clinical setting. There is a growing need for medical centers to offer clinically relevant functional neuroimaging courses that emphasize the multifaceted and multidisciplinary nature of this field. In this paper, we describe the implementation of a functional neuroimaging course focusing on cognitive disorders that might serve as a model for other medical centers. We identify key components of an active learning course design that impact student learning gains in methods and issues pertaining to functional neuroimaging that deserve consideration when optimizing the medical neuroimaging curriculum. Methods Learning gains associated with the course were assessed using polychoric correlation analysis of responses to the SALG (Student Assessment of Learning Gains) instrument. Results Student gains in the functional neuroimaging of cognition as assessed by the SALG instrument were strongly associated with several aspects of the course design. Conclusion Our implementation of a multidisciplinary and active learning functional neuroimaging course produced positive learning outcomes. Inquiry-based learning activities and an online learning environment contributed positively to reported gains. This functional neuroimaging course design may serve as a useful model for other medical centers. PMID:17953758
Matthews, Grant
2004-12-01
The Geostationary Earth Radiation Budget (GERB) experiment is a broadband satellite radiometer instrument program intended to resolve remaining uncertainties surrounding the effect of cloud radiative feedback on future climate change. By use of a custom-designed diffraction-aberration telescope model, the GERB detector spatial response is recovered by deconvolution applied to the ground calibration point-spread function (PSF) measurements. An ensemble of randomly generated white-noise test scenes, combined with the measured telescope transfer function results in the effect of noise on the deconvolution being significantly reduced. With the recovered detector response as a base, the same model is applied in construction of the predicted in-flight field-of-view response of each GERB pixel to both short- and long-wave Earth radiance. The results of this study can now be used to simulate and investigate the instantaneous sampling errors incurred by GERB. Also, the developed deconvolution method may be highly applicable in enhancing images or PSF data for any telescope system for which a wave-front error measurement is available.
Disentangling the Roles of Approach, Activation and Valence in Instrumental and Pavlovian Responding
Huys, Quentin J. M.; Cools, Roshan; Gölzer, Martin; Friedel, Eva; Heinz, Andreas; Dolan, Raymond J.; Dayan, Peter
2011-01-01
Hard-wired, Pavlovian, responses elicited by predictions of rewards and punishments exert significant benevolent and malevolent influences over instrumentally-appropriate actions. These influences come in two main groups, defined along anatomical, pharmacological, behavioural and functional lines. Investigations of the influences have so far concentrated on the groups as a whole; here we take the critical step of looking inside each group, using a detailed reinforcement learning model to distinguish effects to do with value, specific actions, and general activation or inhibition. We show a high degree of sophistication in Pavlovian influences, with appetitive Pavlovian stimuli specifically promoting approach and inhibiting withdrawal, and aversive Pavlovian stimuli promoting withdrawal and inhibiting approach. These influences account for differences in the instrumental performance of approach and withdrawal behaviours. Finally, although losses are as informative as gains, we find that subjects neglect losses in their instrumental learning. Our findings argue for a view of the Pavlovian system as a constraint or prior, facilitating learning by alleviating computational costs that come with increased flexibility. PMID:21556131
Assessing health status and quality-of-life instruments: attributes and review criteria.
Aaronson, Neil; Alonso, Jordi; Burnam, Audrey; Lohr, Kathleen N; Patrick, Donald L; Perrin, Edward; Stein, Ruth E
2002-05-01
The field of health status and quality of life (QoL) measurement - as a formal discipline with a cohesive theoretical framework, accepted methods, and diverse applications--has been evolving for the better part of 30 years. To identify health status and QoL instruments and review them against rigorous criteria as a precursor to creating an instrument library for later dissemination, the Medical Outcomes Trust in 1994 created an independently functioning Scientific Advisory Committee (SAC). In the mid-1990s, the SAC defined a set of attributes and criteria to carry out instrument assessments; 5 years later, it updated and revised these materials to take account of the expanding theories and technologies upon which such instruments were being developed. This paper offers the SAC's current conceptualization of eight key attributes of health status and QoL instruments (i.e., conceptual and measurement model; reliability; validity; responsiveness; interpretability; respondent and administrative burden; alternate forms; and cultural and language adaptations) and the criteria by which instruments would be reviewed on each of those attributes. These are suggested guidelines for the field to consider and debate; as measurement techniques become both more familiar and more sophisticated, we expect that experts will wish to update and refine these criteria accordingly.
The PROMIS physical function correlates with the QuickDASH in patients with upper extremity illness.
Overbeek, Celeste L; Nota, Sjoerd P F T; Jayakumar, Prakash; Hageman, Michiel G; Ring, David
2015-01-01
To assess disability more efficiently with less burden on the patient, the National Institutes of Health has developed the Patient Reported Outcomes Measurement Information System (PROMIS) Physical Function-an instrument based on item response theory and using computer adaptive testing (CAT). Initially, upper and lower extremity disabilities were not separated and we were curious if the PROMIS Physical Function CAT could measure upper extremity disability and the Quick Disability of Arm, Shoulder and Hand (QuickDASH). We aimed to find correlation between the PROMIS Physical Function and the QuickDASH questionnaires in patients with upper extremity illness. Secondarily, we addressed whether the PROMIS Physical Function and QuickDASH correlate with the PROMIS Depression CAT and PROMIS Pain Interference CAT instruments. Finally, we assessed factors associated with QuickDASH and PROMIS Physical Function in multivariable analysis. A cohort of 93 outpatients with upper extremity illnesses completed the QuickDASH and three PROMIS CAT questionnaires: Physical Function, Pain Interference, and Depression. Pain intensity was measured with an 11-point ordinal measure (0-10 numeric rating scale). Correlation between PROMIS Physical Function and the QuickDASH was assessed. Factors that correlated with the PROMIS Physical Function and QuickDASH were assessed in multivariable regression analysis after initial bivariate analysis. There was a moderate correlation between the PROMIS Physical Function and the QuickDASH questionnaire (r=-0.55, p<0.001). Greater disability as measured with the PROMIS and QuickDASH correlated most strongly with PROMIS Depression (r=-0.35, p<0.001 and r=0.34, p<0.001 respectively) and Pain Interference (r=-0.51, p<0.001 and r=0.74, p<0.001 respectively). The factors accounting for the variability in PROMIS scores are comparable to those for the QuickDASH except that the PROMIS Physical Function is influenced by other pain conditions while the QuickDASH is not. The PROMIS Physical Function instrument may be used as an upper extremity disability measure, as it correlates with the QuickDASH questionnaire, and both instruments are influenced most strongly by the degree to which pain interferes with achieving goals. Level III, diagnostic study. See the Instructions for Authors for a complete description of levels of evidence.
Qualifying Spirit and Opportunity to Martian Landing Loads with Centrifuge Testing
NASA Technical Reports Server (NTRS)
Coleman, Michelle R.; Davis, Greg
2004-01-01
This viewgraph presentation reviews the drop test used to test the Mars lander. The objective of the test was to demonstrate the structural and functional integrity of the development test Model (DTM). Rover Basepetal when subjected to the landing event. The test module was instrumented with accelerometers to measure the kinematic response of the test article during impact.
ERIC Educational Resources Information Center
Hellweg, Susan A.
A study was designed to examine an underlying assumption regarding the use of the semantic differential in measuring the credibility and homophily of a communicator, namely, that responses to an ideal source position themselves at one extreme end of the scale, reflecting the monotonic function of the instrument such that the highest response…
Developing a measure of local agency adaptation to emergencies: a metric.
Schuh, Russell G; Tony Eichelberger, R; Stebbins, Samuel; Pomer, Bruce; Duran, Luis; Mahoney, John F; Keane, Christopher; Lin, Chyongchiou J; Potter, Margaret A
2012-11-01
Local public health agencies often must respond to health-related emergencies or disasters, while continuing to fulfill all public health functions for which they are funded. This article reports the development and initial pilot test of a method for measuring the nature and degree of a public health agency's response to such an emergency or disaster. How the instrument was developed as well as the initial results from the pilot study of four local public health systems (LPHSs) are presented and discussed. The instrument measured the extent to which each function and division of each of the four LPHSs were affected and provided a metric that could be used across LPHSs to indicate the burden experienced by each due to the emergency. Results obtained from the pilot study indicate that size and complexity of an LPHS was not predictive of its ability to respond to the emergency. These results support the use of the framework and associated measurement procedures to provide valuable information to managers responsible for such LPHSs. Such information should provide a foundation for comparing variations in performance and outcomes to various types of emergencies that vary in their severity and focus. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Huber, Martin; Blumthaler, Mario; Schreder, Josef
2002-01-01
Within the frame of the Austrian UV Monitoring Network, repeated recalibrations of Solar Light Sunburn Meters between December 1997 and March 2000 have shown significant temporal changes in the instruments' relative spectral response function as well as in their absolute calibration. Therefore, laboratory investigations of the effects of ambient temperature and internal relative humidity on the behavior of two Sunburn Meters have been performed. Despite internal temperature stabilization, both instruments show significant dependence of their spectral response function on ambient temperature. When the outside temperature of the detector's housing varies between 13 degree(s)C and 44 degree(s)C, spectral sensitivity changes by up to 10% in the UVB range and by up to a factor of 2 in the UVA range, depending on internal relative humidity. As a consequence, output voltage variations of 10% are observed when the detector is mounted in front of a 1000 W halogen lamp and its internal relative humidity is changed while its ambient temperature is kept constant. Whereas temperature effects take place within several hours, instabilities due to variations in internal relative humidity show typical time constants in the order of several days.
Strauss, Gregory P; Keller, William R; Buchanan, Robert W; Gold, James M; Fischer, Bernard A; McMahon, Robert P; Catalano, Lauren T; Culbreth, Adam J; Carpenter, William T; Kirkpatrick, Brian
2012-12-01
The current study examined the psychometric properties of the Brief Negative Symptom Scale (BNSS), a next-generation rating instrument developed in response to the NIMH sponsored consensus development conference on negative symptoms. Participants included 100 individuals with a DSM-IV diagnosis of schizophrenia or schizoaffective disorder who completed a clinical interview designed to assess negative, positive, disorganized, and general psychiatric symptoms, as well as functional outcome. A battery of anhedonia questionnaires and neuropsychological tests were also administered. Results indicated that the BNSS has excellent internal consistency and temporal stability, as well as good convergent and discriminant validity in its relationships with other symptom rating scales, functional outcome, self-reported anhedonia, and neuropsychological test scores. Given its brevity (13-items, 15-minute interview) and good psychometric characteristics, the BNSS can be considered a promising new instrument for use in clinical trials. Copyright © 2012 Elsevier B.V. All rights reserved.
The N2N instrument to evaluate healthy work environments: an Italian validation.
Palese, Alvisa; Dante, Angelo; Tonzar, Laura; Balboni, Bernardo
2014-02-01
The aims of the study were to (a) validate N2N Healthy Work Environment tool, (b) assess the healthiness of work environments as perceived by nurses themselves and (c) identify the factors associated with Italian nurses' perception of work environment healthiness. The linguistic and cultural adaptation of USA-N2N Healthy Work Environments was achieved through a process of forward/backward translation. Content validity was assessed by three expert nurses. The stability of the instrument was checked with a test/retest evaluation. The instrument psychometric properties, the confirmatory factor analysis as well the healthiness of the work environment and its determinant factors were evaluated with a sample of 294 nurses. The content and face validity of the N2N Healthy Work Environment instrument was confirmed. The instrument demonstrated good internal consistency (α of 0.82), excellent stability values (ρ > 0.70) and high levels of acceptability (response rate: 96.4 %). The confirmatory factor analysis has corroborated the existence of two factors as documented in the original instrument (Mays et al. in J Nurs Manag 19:18-26, 2011). Eighty-seven (29.6 %) nurses perceived the work environment where they work as "healthy". Working under a functional model of care delivery (χ(2) 24.856, p 0.000) and being responsible for one project or more (χ(2) 5.256, p 0.021) were associated with healthy environments. The instrument--valid and reliable, short in the number of items, easy to understand and based on international standards--allows a systematic assessment of the healthiness of the environment and might provide not only the opportunity to evaluate the effects of new organizational models and interventions, but also the possibility to activate a process of self-analysis and a process of ongoing review. The instrument can be used to systematically check the healthiness of Italian working environments, allowing for organizational diagnosis, targeted interventions and international comparisons.
ERIC Educational Resources Information Center
Berg, Craig; Boote, Stacy
2017-01-01
Prior graphing research has demonstrated that clinical interviews and free-response instruments produce very different results than multiple-choice instruments, indicating potential validity problems when using multiple-choice instruments to assess graphing skills (Berg & Smith in "Science Education," 78(6), 527-554, 1994). Extending…
Financial Responsibilities for Underground Injection Well Owners or Operators
This page provides information on UIC financial responsibility requirements, qualifying financial instrumentsRoles and responsibilities for operators and UIC Directors UIC Director’s and review procedures for financial responsibility instruments.
Modulating the Levels of Plant Hormone Cytokinins at the Host-Pathogen Interface.
Naseem, Muhammad; Shams, Shabana; Roitsch, Thomas
2017-01-01
Cytokinins are adenine and non-adenine derived heterogeneous class of regulatory molecules that participate in almost every aspect of plant biology. They also affect plant defense responses as well as help microbial pathogens to establish pathogenesis. The functional approaches that ensure desired and subtle modulations in the levels of plant cytokinins are highly instrumental in assessing their functions in plant immunity. Here, we describe a detailed working protocol regarding the enhanced production of cytokinins from plants that harbor isopentenyltransferase (IPT) enzyme gene under the control of 4xJERE (jasmonic acid and elicitor-responsive element) pathogen-inducible promoter. Our devised expression system is a context-dependent solution when it comes to investigating host-pathogen interactions under the modulated conditions of plant cytokinins.
Rose, Matthias; Bjorner, Jakob B; Gandek, Barbara; Bruce, Bonnie; Fries, James F; Ware, John E
2014-05-01
To document the development and psychometric evaluation of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) item bank and static instruments. The items were evaluated using qualitative and quantitative methods. A total of 16,065 adults answered item subsets (n>2,200/item) on the Internet, with oversampling of the chronically ill. Classical test and item response theory methods were used to evaluate 149 PROMIS PF items plus 10 Short Form-36 and 20 Health Assessment Questionnaire-Disability Index items. A graded response model was used to estimate item parameters, which were normed to a mean of 50 (standard deviation [SD]=10) in a US general population sample. The final bank consists of 124 PROMIS items covering upper, central, and lower extremity functions and instrumental activities of daily living. In simulations, a 10-item computerized adaptive test (CAT) eliminated floor and decreased ceiling effects, achieving higher measurement precision than any comparable length static tool across four SDs of the measurement range. Improved psychometric properties were transferred to the CAT's superior ability to identify differences between age and disease groups. The item bank provides a common metric and can improve the measurement of PF by facilitating the standardization of patient-reported outcome measures and implementation of CATs for more efficient PF assessments over a larger range. Copyright © 2014. Published by Elsevier Inc.
On Calibrations Using the Crab Nebula as a Standard Candle
NASA Technical Reports Server (NTRS)
Weisskopf, Martin; Guainazzi, Matteo; Jahoda, Keith; Shaposhnikov, Nikolai; ODell, Stephen; Zavlin, Vyacheslav; Wilson-Hodge, Colleen; Elsner, Ronald
2009-01-01
Inspired by a recent paper (Kirsch et al. 2005) on possible use of the Crab Nebula as a standard candle for calibrating X-ray response func tions, we examine possible consequences of intrinsic departures from a single (absorbed) power law upon such calibrations. We limited our analyses to three more modern X-ray instruments -- the ROSAT/PSPC, th e RXTE/PCA, and the XMM-Newton/EPIC-pn. The results are unexpected an d indicate a need to refine two of the three response functions studi ed. The implications for Chandra will be discussed.
Canela, Carlos; Schleifer, Roman; Dube, Anish; Hengartner, Michael P; Ebner, Gerhard; Seifritz, Erich; Liebrenz, Michael
2016-03-01
Occupational capacity evaluations have previously been subject to criticism for lacking in quality and consistency. To the authors' knowledge, there is no clear consensus on the best way to formally assess functioning within capacity evaluations. In this review we investigated different instruments that are used to assess functioning in occupational capacity evaluations. Systematic review of the literature. Though several instruments that assess functional capacity were found in our search, a specific validated instrument assessing occupational capacity as part of a larger psychiatric evaluation was not found. The limitations of the existing instruments on assessing functional capacity are discussed. Medical experts relying on instruments to conduct functional capacity evaluations should be cognizant of their limitations. The findings call for the development and use of an instrument specifically designed to assess the functional and occupational capacity of psychiatric patients, which is also likely to improve the quality of these reports. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Ahlers, B.; Hutchinson, I.; Ingley, R.
2017-11-01
A spectrometer for combined Raman and Laser Induced Breakdown Spectroscopy (LIBS) is amongst the different instruments that have been pre-selected for the Pasteur payload of the ExoMars rover. It is regarded as a fundamental, next-generation instrument for organic, mineralogical and elemental characterisation of Martian soil, rock samples and organic molecules. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities [1]. The combined Raman / LIBS instrument has been recommended as the highest priority mineralogy instrument to be included in the rover's analytical laboratory for the following tasks: Analyse surface and sub-surface soil and rocks on Mars, identify organics in the search for life and determine soil origin & toxicity. The synergy of the system is evident: the Raman spectrometer is dedicated to molecular analysis of organics and minerals; the LIBS provides information on the sample's elemental composition. An international team, under ESA contract and with the leadership of TNO Science and Industry, has built and tested an Elegant Bread Board (EBB) of the combined Raman / LIBS instrument. The EBB comprises a specifically designed, extremely compact, spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. The EBB also includes lasers, illumination and imaging optics as well as fibre optics for light transfer. A summary of the functional and environmental requirements together with a description of the optical design and its expected performance are described in [2]. The EBB was developed and constructed to verify the instruments' end-to-end functional performance with natural samples. The combined Raman / LIBS EBB realisation and test results of natural samples will be presented. For the Flight Model (FM) instrument, currently in the design phase, the Netherlands will be responsible for the design, development and verification of the spectrometer unit, while the UK provides the detector. The differences between the EBB and the FM will be demonstrated.
Stamm, Tanja A; Cieza, Alarcos; Machold, Klaus P; Smolen, Josef S; Stucki, Gerold
2004-12-15
To compare the content of clinical, occupation-based instruments that are used in adult rheumatology and musculoskeletal rehabilitation in occupational therapy based on the International Classification of Functioning, Disability and Health (ICF). Clinical instruments of occupational performance and occupation in adult rehabilitation and rheumatology were identified in a literature search. All items of these instruments were linked to the ICF categories according to 10 linking rules. On the basis of the linking, the content of these instruments was compared and the relationship between the capacity and performance component explored. The following 7 instruments were identified: the Canadian Occupational Performance Measure, the Assessment of Motor and Process Skills, the Sequential Occupational Dexterity Assessment, the Jebson Taylor Hand Function Test, the Moberg Picking Up Test, the Button Test, and the Functional Dexterity Test. The items of the 7 instruments were linked to 53 different ICF categories. Five items could not be linked to the ICF. The areas covered by the 7 occupation-based instruments differ importantly: The main focus of all 7 instruments is on the ICF component activities and participation. Body functions are covered by 2 instruments. Two instruments were linked to 1 single ICF category only. Clinicians and researchers who need to select an occupation-based instrument must be aware of the areas that are covered by this instrument and the potential areas that are not covered at all.
de Boer, A Siebe; Tjioe, Roderik J C; Van der Sijde, Fleur; Meuffels, Duncan E; den Hoed, Pieter T; Van der Vlies, Cornelis H; Tuinebreijer, Wim E; Verhofstad, Michael H J; Van Lieshout, Esther M M
2017-08-03
The American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale is among the most commonly used instruments for measuring outcome of treatment in patients who sustained a complex ankle or hindfoot injury. It consists of a patient-reported and a physician-reported part. A validated, Dutch version of this instrument is currently not available. The aim of this study was to translate the instrument into Dutch and to determine the measurement properties of the AOFAS Ankle-Hindfoot Scale Dutch language version (DLV) in patients with a unilateral ankle fracture. Multicentre (two Dutch hospitals), prospective observational study. In total, 142 patients with a unilateral ankle fracture were included. Ten patients were lost to follow-up. Patients completed the subjective (patient-reported) part of the AOFAS Ankle-Hindfoot Scale-DLV. A physician or trained physician-assistant completed the physician-reported part. For comparison and evaluation of the measuring characteristics, the Foot Function Index and the Short Form-36 were completed by the patient. Descriptive statistics (including floor and ceiling effects), reliability (ie, internal consistency), construct validity, reproducibility (ie, test-retest reliability, agreement and smallest detectable change) and responsiveness were determined. The AOFAS-DLV and its subscales showed good internal consistency (Cronbach's α >0.90). Construct validity and longitudinal validity were proven to be adequate (76.5% of predefined hypotheses were confirmed). Floor effects were not present. Ceiling effects were present from 6 months onwards, as expected. Responsiveness was adequate, with a smallest detectable change of 12.0 points. The AOFAS-DLV is a reliable, valid and responsive measurement instrument for evaluating functional outcome in patients with a unilateral ankle fracture. This implies that the questionnaire is suitable to compare different treatment modalities within this population or to compare outcome across hospitals. The Netherlands Trial Register (NTR5613; 05-jan-2016). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
[Functional neuroanatomy of implicit learning: associative, motor and habit].
Correa, M
The present review focuses on the neuroanatomy of aspects of implicit learning that involve stimulus-response associations, such as classical and instrumental conditioning, motor learning and habit formation. These types of learning all require a progression in the acquisition of procedural information about 'how to do things' instead of 'what things are'. These forms of implicit learning share the neural substrate formed mainly by brain circuits involving basal ganglia, prefrontal cortex and amygdala. The relationship between pavlovian and instrumental learning is shown in the transference and autoshaping studies. There has been a resurgence of interest in habit learning because of the suggestion that addiction is a process that progresses from a reinforced response to a habit in which the stimulus-response association is supraselected and becomes independent of voluntary cognitive control. Dopamine has demonstrated to be involved in the acquisition of these procedures. The different forms of procedural learning studied here all are characterized by stimulus-response-reinforcement associations, but there are differences between them in terms of the degree to which some of these associations or components are strengthened. These different patterns of association are partially regulated by the degree of involvement of the frontal-striatal-amygdala circuits.
Chiarotto, Alessandro; Maxwell, Lara J; Terwee, Caroline B; Wells, George A; Tugwell, Peter; Ostelo, Raymond W
2016-10-01
Physical functioning is a core outcome domain to be measured in nonspecific low back pain (NSLBP). A panel of experts recommended the Roland-Morris Disability Questionnaire (RMDQ) and Oswestry Disability Index (ODI) to measure this domain. The original 24-item RMDQ and ODI 2.1a are recommended by their developers. The purpose of this study was to evaluate whether the 24-item RMDQ or the ODI 2.1a has better measurement properties than the other to measure physical functioning in adult patients with NSLBP. Bibliographic databases (MEDLINE, Embase, CINAHL, SportDiscus, PsycINFO, and Google Scholar), references of existing reviews, and citation tracking were the data sources. Two reviewers selected studies performing a head-to-head comparison of measurement properties (reliability, validity, and responsiveness) of the 2 questionnaires. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist was used to assess the methodological quality of these studies. The studies' characteristics and results were extracted by 2 reviewers. A meta-analysis was conducted when there was sufficient clinical and methodological homogeneity among studies. Nine articles were included, for a total of 11 studies assessing 5 measurement properties. All studies were classified as having poor or fair methodological quality. The ODI displayed better test-retest reliability and smaller measurement error, whereas the RMDQ presented better construct validity as a measure of physical functioning. There was conflicting evidence for both instruments regarding responsiveness and inconclusive evidence for internal consistency. The results of this review are not generalizable to all available versions of these questionnaires or to patients with specific causes for their LBP. Based on existing head-to-head comparison studies, there are no strong reasons to prefer 1 of these 2 instruments to measure physical functioning in patients with NSLBP, but studies of higher quality are needed to confirm this conclusion. Foremost, content, structural, and cross-cultural validity of these questionnaires in patients with NSLBP should be assessed and compared. © 2016 American Physical Therapy Association.
Bornstein, Daniel B; Pate, Russell R; Beets, Michael W; Saunders, Ruth P; Blair, Steven N
2015-06-01
Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement in physical activity coalitions. The study was carried out in three phases: (a) developing a draft survey, (b) assessing the content validity of the draft survey, and (c) assessing the underlying factor structure, reliability, and validity of the survey. A cross-sectional design was employed. In Phase 1, a team of experts in survey development produced a draft survey. In Phase 2, the content validity of the draft survey was evaluated by a panel of individuals with expertise in physical activity coalitions. In Phase 3, the survey was administered to 120 individuals on local-, state-, and national-level physical activity coalitions. Responses were subjected to an exploratory factor analysis in order to determine the survey's underlying factor structure, reliability, and validity. Phases 1 and 2yielded a survey instrument with demonstrated content validity. Phase 3 yielded a three-factor model with three subscales: Strategic Alignment, Organizational Alignment, and Providing Input. Each subscale demonstrated high internal consistency reliability and construct validity. The survey instrument developed here demonstrated sound psychometric properties and provides new insight into organizational member involvement in physical activity coalitions. This instrument may be an important tool in developing a more complete picture of coalition functioning in physical activity coalitions specifically and health-based coalitions overall. © 2014 Society for Public Health Education.
Barnes, Douglas; Linton, Judith L; Sullivan, Elroy; Bagley, Anita; Oeffinger, Donna; Abel, Mark; Damiano, Diane; Gorton, George; Nicholson, Diane; Romness, Mark; Rogers, Sarah; Tylkowski, Chester
2008-01-01
The Pediatric Outcomes Data Collection Instrument (PODCI) was developed in 1994 as a patient-based tool for use across a broad age range and wide array of musculoskeletal disorders, including children with cerebral palsy (CP). The purpose of this study was to establish means and SDs of the Parent PODCI measures by age groups and Gross Motor Function Classification System (GMFCS) levels for ambulatory children with CP. This instrument was one of several studied in a prospective, multicenter project of ambulatory patients with CP between the aged 4 and 18 years and GMFCS levels I through III. Participants included 338 boys and 221 girls at a mean age of 11.1 years, with 370 diplegic, 162 hemiplegic, and 27 quadriplegic. Both baseline and follow-up data sets of the completed Parent PODCI responses were statistically analyzed. Age was identified as a significant predictor of the PODCI measures of Upper Extremity Function, Transfers and Basic Mobility, Global Function, and Happiness With Physical Condition. Gross Motor Function Classification System levels was a significant predictor of Transfers and Basic Mobility, Sports and Physical Function, and Global Function. Pattern of involvement, sex, and prior orthopaedic surgery were not statistically significant predictors for any of the Parent PODCI measures. Mean and SD scores were calculated for age groups stratified by GMFCS levels. Analysis of the follow-up data set validated the findings derived from the baseline data. Linear regression equations were derived, with age as a continuous variable and GMFCS levels as a categorical variable, to be used for Parent PODCI predicted scores. The results of this study provide clinicians and researchers with a set of Parent PODCI values for comparison to age- and severity-matched populations of ambulatory patients with CP.
Chong, Hyun Ju; Han, Soo Jeong; Kim, Yong Jae; Park, Hye Young; Kim, Soo Ji
2014-01-01
While a number of studies have tested the therapeutic effectiveness of playing musical instruments, such as the electronic keyboard using Musical Instrument Digital Interface (MIDI), it is still unclear whether outcomes of electronic keyboard playing are related to hand function tests. The purpose of this study was to investigate the correlation between MIDI-keyboard playing and hand function tests, including grip strength, Box and Block test (BBT), and Jensen-Taylor Hand Function Test (JTHF). A total of 66 stroke patients were recruited from medical centers and were classified into acute (n = 21), subacute (n = 28), and chronic (n = 17) recovery stages. The participants' mean age was 60.5 years. The MIDI-keyboard playing protocol based on sequential key pressing was implemented. All hand function tests were performed by certified occupational therapists. MIDI scores from participants at all three recovery stages were significantly correlated with BBT and grip strength. Overall, MIDI-keyboard playing scores demonstrated moderate to high correlations with hand function tests except for participants at the chronic stage and the JTHF, which showed no correlation. These findings suggest that MIDI-keyboard playing has great potential as an assessment tool of hand function, especially hand dexterity in acute and subacute stroke patients. Further studies are needed to refine the specific keyboard playing tasks that increase responsiveness to traditional hand function tests.
Jafari, Peyman; Bagheri, Zahra; Ayatollahi, Seyyed Mohamad Taghi; Soltani, Zahra
2012-03-13
Item response theory (IRT) is extensively used to develop adaptive instruments of health-related quality of life (HRQoL). However, each IRT model has its own function to estimate item and category parameters, and hence different results may be found using the same response categories with different IRT models. The present study used the Rasch rating scale model (RSM) to examine and reassess the psychometric properties of the Persian version of the PedsQL™ 4.0 Generic Core Scales. The PedsQL™ 4.0 Generic Core Scales was completed by 938 Iranian school children and their parents. Convergent, discriminant and construct validity of the instrument were assessed by classical test theory (CTT). The RSM was applied to investigate person and item reliability, item statistics and ordering of response categories. The CTT method showed that the scaling success rate for convergent and discriminant validity were 100% in all domains with the exception of physical health in the child self-report. Moreover, confirmatory factor analysis supported a four-factor model similar to its original version. The RSM showed that 22 out of 23 items had acceptable infit and outfit statistics (<1.4, >0.6), person reliabilities were low, item reliabilities were high, and item difficulty ranged from -1.01 to 0.71 and -0.68 to 0.43 for child self-report and parent proxy-report, respectively. Also the RSM showed that successive response categories for all items were not located in the expected order. This study revealed that, in all domains, the five response categories did not perform adequately. It is not known whether this problem is a function of the meaning of the response choices in the Persian language or an artifact of a mostly healthy population that did not use the full range of the response categories. The response categories should be evaluated in further validation studies, especially in large samples of chronically ill patients.
Electrophysiology of connection current spikes.
Fish, Raymond M; Geddes, Leslie A
2008-12-01
Connection to a 60-Hz or other voltage source can result in cardiac dysrhythmias, a startle reaction, muscle contractions, and a variety of other physiological responses. Such responses can lead to injury, especially if significant ventricular cardiac dysrhythmias occur, or if a person is working at some height above ground and falls as a result of a musculoskeletal response. Physiological reactions are known to relate to intensity and duration of current exposure. The connection current that flows is a function of the applied voltage at the instant of connection, and the electrical impedance encountered by the voltage source in contact with the skin or other body tissues. In this article we describe a rarely investigated phenomenon, namely a contact, or connection, current spike that is many times higher than the steady-state current. This current spike occurs when an electrical connection is made at a non-zero voltage time in a sine wave or other waveform. Such current spikes may occur when electronic or manual switching or connecting of conductors occurs in electronic instrumentation connected to a patient. These findings are relevant to medical devices and instrumentation and to electrical safety in general.
Spanjer, Jerry; Groothoff, Johan W; Brouwer, Sandra
2011-01-01
To systematically review the quality of the psychometric properties of instruments for assessing functional limitations in workers applying for disability benefit. Electronic searches of Medline, Embase, CINAHL and PsycINFO were performed to identify studies focusing on the psychometric properties of instruments used to assess functional limitations in workers' compensation claimants. Two independent reviewers applied the inclusion criteria to select relevant articles and then evaluated the psychometric qualities of the instruments found. Of the 712 articles that were identified, 10 studies met the inclusion criteria, reporting on four instruments: the Roland-Morris Disability Questionnaire (RMDQ), the Patient-Specific Functional Scale (PSFS), the Isernhagen Work System (IWS) and the Multiperspective Multidimensional Pain Assessment Protocol (MMPAP). The questionnaires (RMDQ and PSFS) did not focus specifically on the work situation and measured three to eight functional limitations. The psychometric qualities of the IWS were poor to moderate. For the MMPAP, only predictive validity was measured. The instruments assessed a range varying between 3 and 34 physical functional limitations. No instruments were found for assessing mental limitations in workers' compensation claimants. Studies on four instruments specifically focusing on assessing physical functional limitations in workers applying for disability benefit were found. All four instruments have limitations regarding their psychometric qualities or contents. Since the RMDQ has the best demonstrated psychometric qualities and takes little time to complete it, we recommend the RMDQ for clinicians in rehabilitation. For the assessment of functional limitations in workers applying for disability benefit a combination of questionnaires, performance tests or interviews together with the judgment by physicians looks the most promising.
Molecular substrates of action control in cortico-striatal circuits.
Shiflett, Michael W; Balleine, Bernard W
2011-09-15
The purpose of this review is to describe the molecular mechanisms in the striatum that mediate reward-based learning and action control during instrumental conditioning. Experiments assessing the neural bases of instrumental conditioning have uncovered functional circuits in the striatum, including dorsal and ventral striatal sub-regions, involved in action-outcome learning, stimulus-response learning, and the motivational control of action by reward-associated cues. Integration of dopamine (DA) and glutamate neurotransmission within these striatal sub-regions is hypothesized to enable learning and action control through its role in shaping synaptic plasticity and cellular excitability. The extracellular signal regulated kinase (ERK) appears to be particularly important for reward-based learning and action control due to its sensitivity to combined DA and glutamate receptor activation and its involvement in a range of cellular functions. ERK activation in striatal neurons is proposed to have a dual role in both the learning and performance factors that contribute to instrumental conditioning through its regulation of plasticity-related transcription factors and its modulation of intrinsic cellular excitability. Furthermore, perturbation of ERK activation by drugs of abuse may give rise to behavioral disorders such as addiction. Copyright © 2011 Elsevier Ltd. All rights reserved.
James Paget Henry--a retrospective.
Meehan, J P; Meehan, W P
1997-01-01
James Paget Henry really began his productive research career at the outset of the second world war. His studies of acceleration and the anoxia of high altitude were supported by the development of then new techniques of measuring and recording critical physiologic parameters such as vascular pressures, respiratory functions and haemoglobin saturation. His inquisitive mind made productive use of the instruments that had to be made by skilled instrument makers working in university shops. Much of this instrumentation has now found its way into the clinical arena where it is now the main armamentarium of cardiac diagnostic and respiratory function laboratories. His work in the space program preceeded that of the Russians but did not get recognition until Sputnik awakened the world to the possibilities of space flight. His development of the concept of a cardiovascular basis for fluid volume control and the supportive investigative work undertaken constitute a milestone in the annals of experimental physiology. The chimpanzees used in Project Mercury were found to be hypertensive which was related to the method of capture used by the commercial suppliers. This lead Jim to study the effect of early experience on resting blood pressure, an effort that soon developed into provocative studies of the biological basis of the stress response.
Research pressure instrumentation for NASA Space Shuttle main engine, modification no. 5
NASA Technical Reports Server (NTRS)
Anderson, P. J.; Nussbaum, P.; Gustafson, G.
1984-01-01
The advantages of silicon piezoresistive strain sensing technology are being used to achieve the objectives of state of the art pressure sensors for SSME applications. The integration of multiple functions on a single chip is the key attribute being exploited. Progress is reported in transducer packaging and materials; silicon resistor characterization at cryogenic temperatures; chip mounting; and frequency response optimization.
An Application of the Rasch Measurement Theory to an Assessment of Geometric Thinking Levels
ERIC Educational Resources Information Center
Stols, Gerrit; Long, Caroline; Dunne, Tim
2015-01-01
The purpose of this study is to apply the Rasch model to investigate both the Van Hiele theory for geometric development and an associated test. In terms of the test, the objective is to investigate the functioning of a classic 25-item instrument designed to identify levels of geometric proficiency. The dataset of responses by 244 students (106…
Crossley, Matthew J; Horvitz, Jon C; Balsam, Peter D; Ashby, F Gregory
2016-01-01
The basal ganglia are a collection of subcortical nuclei thought to underlie a wide variety of vertebrate behavior. Although a great deal is known about the functional and physiological properties of the basal ganglia, relatively few models have been formally developed that have been tested against both behavioral and physiological data. Our previous work (Ashby FG, Crossley MJ. J Cogn Neurosci 23: 1549-1566, 2011) showed that a model grounded in the neurobiology of the basal ganglia could account for basic single-neuron recording data, as well as behavioral phenomena such as fast reacquisition that constrain models of conditioning. In this article we show that this same model accounts for a variety of appetitive instrumental conditioning phenomena, including the partial reinforcement extinction (PRE) effect, rapid and slowed reacquisition following extinction, and renewal of previously extinguished instrumental responses by environmental context cues. Copyright © 2016 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Pound, M. W.; Wolfire, M. G.; Amarnath, N. S.
2003-12-01
The Dust InfraRed ToolBox (DIRT - a part of the Web Infrared ToolShed, or WITS, located at http://dustem.astro.umd.edu) is a Java applet for modeling astrophysical processes in circumstellar shells around young and evolved stars. DIRT has been used by the astrophysics community for about 5 years. Users can automatically and efficiently search grids of pre-calculated models to fit their data. A large set of physical parameters and dust types are included in the model database, which contains over 500,000 models. We are adding new functionality to DIRT to support new missions like SIRTF and SOFIA. A new Instrument module allows for plotting of the model points convolved with the spatial and spectral responses of the selected instrument. This lets users better fit data from specific instruments. Currently, we have implemented modules for the Infrared Array Camera (IRAC) and Multiband Imaging Photometer (MIPS) on SIRTF.
Mathier, Michael A; Shen, You-Tang; Shannon, Richard P
2002-12-01
The aim of this study was to explore the characteristics and mechanisms of the cardiovascular effects of cocaine in dilated cardiomyopathy. We studied the cardiovascular responses to acute intravenous cocaine (1 mg/kg) in 8 conscious, chronically instrumented dogs before and after the development of dilated cardiomyopathy induced by rapid ventricular pacing. To help elucidate the role of altered baroreflex function in mediating the cardiovascular effects of cocaine, we also studied responses in 3 conscious, chronically instrumented dogs that had undergone surgical sinoaortic baroreceptor denervation. Cocaine produced greater increases in heart rate (+57 +/- 8% from 112 +/- 5 beats/min versus +28 +/- 3% from 100 +/- 4 beats/min; P <.01), first derivative of left ventricular pressure (+30 +/- 5% from 1,714 +/- 147 mm Hg/sec versus +15 +/- 3% from 3,032 +/- 199 mm Hg/sec; P <.01), coronary vascular resistance (+28 +/- 5% from 2.3 +/- 0.3 mm Hg/mL/min versus +11 +/- 5% from 2.2 +/- 0.3 mm Hg/mL/min; P <.05) and plasma norepinephrine concentration (+130 +/- 31% from 462 +/- 102 pg/mL versus +86 +/- 32% from 286 +/- 77 pg/mL; P <.05) in dogs with dilated cardiomyopathy as compared to controls. In addition, responses were much more rapid in onset following the development of dilated cardiomyopathy. Chronotropic and inotropic responses to cocaine were similarly rapid and exaggerated in dogs after baroreceptor denervation. Cocaine produces rapid and exaggerated chronotropic, inotropic, and coronary vasoconstrictor responses in conscious dogs with pacing-induced dilated cardiomyopathy. Alterations in arterial baroreflex function may play a role in these observations, which in turn may underlie the clinically observed association between cocaine and heart failure.
ERIC Educational Resources Information Center
Weaver, Molly A.
This master's thesis reports on a study of the frequency and modes of student responses that demonstrate musical learning in the elementary instrumental music class. Some advances must be made toward more definitive evaluation practices in elementary school instrumental music if instrumental programs are to be justified in terms of improved…
Engel, Lisa; Chui, Adora; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R
2018-03-07
To critically appraise the measurement property evidence (ie, psychometric) for 8 observation-based financial management assessment instruments. Seven databases were searched in May 2015. Two reviewers used an independent decision-agreement process to select studies of measurement property evidence relevant to populations with adulthood acquired cognitive impairment, appraise the quality of the evidence, and extract data. Twenty-one articles were selected. This review used the COnsensus-based Standards for the selection of health Measurement Instruments review guidelines and 4-point tool to appraise evidence. After appraising the methodologic quality, the adequacy of results and volume of evidence per instrument were synthesized. Measurement property evidence with high risk of bias was excluded from the synthesis. The volume of measurement property evidence per instrument is low; most instruments had 1 to 3 included studies. Many included studies had poor methodologic quality per measurement property evidence area examined. Six of the 8 instruments reviewed had supporting construct validity/hypothesis-testing evidence of fair methodologic quality. There is a dearth of acceptable quality content validity, reliability, and responsiveness evidence for all 8 instruments. Rehabilitation practitioners assess financial management functions in adults with acquired cognitive impairments. However, there is limited published evidence to support using any of the reviewed instruments. Practitioners should exercise caution when interpreting the results of these instruments. This review highlights the importance of appraising the quality of measurement property evidence before examining the adequacy of the results and synthesizing the evidence. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Conceptual design of a stray light facility for Earth observation satellites
NASA Astrophysics Data System (ADS)
Stockman, Y.; Hellin, M. L.; Marcotte, S.; Mazy, E.; Versluys, J.; François, M.; Taccola, M.; Zuccaro Marchi, A.
2017-11-01
With the upcoming of TMA or FMA (Three or Four Mirrors Anastigmat) telescope design in Earth Observation system, stray light is a major contributor to the degradation of the image quality. Numerous sources of stray light can be identified and theoretically evaluated. Nevertheless in order to build a stray light model of the instrument, the Point Spread Function(s) of the instrument, i.e., the flux response of the instrument to the flux received at the instrument entrance from an infinite distant point source needs to be determined. This paper presents a conceptual design of a facility placed in a vacuum chamber to eliminate undesired air particles scatter light sources. The specification of the clean room class or vacuum will depend on the required rejection to be measured. Once the vacuum chamber is closed, the stray light level from the external environment can be considered as negligible. Inside the chamber a dedicated baffle design is required to eliminate undesired light generated by the set up itself e.g. retro reflected light away from the instrument under test. This implies blackened shrouds all around the specimen. The proposed illumination system is a 400 mm off axis parabolic mirror with a focal length of 2 m. The off axis design suppresses the problem of stray light that can be generated by the internal obstruction. A dedicated block source is evaluated in order to avoid any stray light coming from the structure around the source pinhole. Dedicated attention is required on the selection of the source to achieve the required large measurement dynamic.
New perspectives for studying organics and the composition of Mars’ atmosphere with ExoMars / NOMAD
NASA Astrophysics Data System (ADS)
Liuzzi, Giuliano; Villanueva, Geronimo Luis; Mumma, Michael J.; Carine Vandaele, Ann; Thomas, Ian; Smith, Michael D.; Daerden, Frank; Ristic, Bojan; Patel, Manish; Bellucci, Giancarlo; Lopez-Moreno, Jose; NOMAD Team
2017-10-01
The ESA/Roscosmos Exomars Trace Gas Orbiter (TGO) mission carries a series of instruments, whose operativity is aimed to achieve unprecedented accuracy in the detection and characterization of spatial distribution and temporal cycles of a broad set of trace species, organics and key isotopologues on Mars. Besides this, the mission is designed for some other specific objectives, such as the mapping of CH4 and D/H isotopologic ratio.In this work, we essentially focus on one of the key payloads of ExoMars, the Nadir and Occultation for Mars Discovery (NOMAD) instrument. This is a grating spectrometer whose design is based on that of the SPICAV/SOIR instrument, already flown on board of Venus Express, and can operate both at the infrared (IR) and visible/UV wavelengths. In addition, the IR channel can be operated both in Solar Occultation (SO) mode, and in Limb Nadir Occultation (LNO), enabling the possibility of a characterization of both the vertical structure of the atmosphere and the mapping of the above cited atmospheric compounds on a global scale.To be prepared to exploit the outstanding possibilities and the high feasibility of the instrument to these science objectives, we have worked on the calibration of the instrument both in SO and LNO modes. Using a large subset of the calibration measurements acquired during the Mars Capture Orbit-1 phase (MCO-1), we have reckoned both the wavenumber calibration across all the spectral interval of the instrument, and characterized the response function of the Acousto-Optical Tunable Filter (AOTF) which selects diffraction orders. The results have been also used to elaborate a model of the instrumental response, and a quantitative model of the observed signal. Based on this, we also present some actual retrieval results on SO and LNO datasets acquired in November 2016 and March 2017, which will serve as a proxy for the forthcoming science operations (starting early 2018).Acknowledgments NASA’s Mars Exploration Program supported this work.
Hu, Jianwei; Gauld, Ian C.
2014-12-01
The U.S. Department of Energy’s Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) project is nearing the final phase of developing several advanced nondestructive assay (NDA) instruments designed to measure spent nuclear fuel assemblies for the purpose of improving nuclear safeguards. Current efforts are focusing on calibrating several of these instruments with spent fuel assemblies at two international spent fuel facilities. Modelling and simulation is expected to play an important role in predicting nuclide compositions, neutron and gamma source terms, and instrument responses in order to inform the instrument calibration procedures. As part of NGSI-SF project, this work was carried outmore » to assess the impacts of uncertainties in the nuclear data used in the calculations of spent fuel content, radiation emissions and instrument responses. Nuclear data is an essential part of nuclear fuel burnup and decay codes and nuclear transport codes. Such codes are routinely used for analysis of spent fuel and NDA safeguards instruments. Hence, the uncertainties existing in the nuclear data used in these codes affect the accuracies of such analysis. In addition, nuclear data uncertainties represent the limiting (smallest) uncertainties that can be expected from nuclear code predictions, and therefore define the highest attainable accuracy of the NDA instrument. This work studies the impacts of nuclear data uncertainties on calculated spent fuel nuclide inventories and the associated NDA instrument response. Recently developed methods within the SCALE code system are applied in this study. The Californium Interrogation with Prompt Neutron instrument was selected to illustrate the impact of these uncertainties on NDA instrument response.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Jianwei; Gauld, Ian C.
The U.S. Department of Energy’s Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) project is nearing the final phase of developing several advanced nondestructive assay (NDA) instruments designed to measure spent nuclear fuel assemblies for the purpose of improving nuclear safeguards. Current efforts are focusing on calibrating several of these instruments with spent fuel assemblies at two international spent fuel facilities. Modelling and simulation is expected to play an important role in predicting nuclide compositions, neutron and gamma source terms, and instrument responses in order to inform the instrument calibration procedures. As part of NGSI-SF project, this work was carried outmore » to assess the impacts of uncertainties in the nuclear data used in the calculations of spent fuel content, radiation emissions and instrument responses. Nuclear data is an essential part of nuclear fuel burnup and decay codes and nuclear transport codes. Such codes are routinely used for analysis of spent fuel and NDA safeguards instruments. Hence, the uncertainties existing in the nuclear data used in these codes affect the accuracies of such analysis. In addition, nuclear data uncertainties represent the limiting (smallest) uncertainties that can be expected from nuclear code predictions, and therefore define the highest attainable accuracy of the NDA instrument. This work studies the impacts of nuclear data uncertainties on calculated spent fuel nuclide inventories and the associated NDA instrument response. Recently developed methods within the SCALE code system are applied in this study. The Californium Interrogation with Prompt Neutron instrument was selected to illustrate the impact of these uncertainties on NDA instrument response.« less
Monitoring Instrument Performance in Regional Broadband Seismic Network Using Ambient Seismic Noise
NASA Astrophysics Data System (ADS)
Ye, F.; Lyu, S.; Lin, J.
2017-12-01
In the past ten years, the number of seismic stations has increased significantly, and regional seismic networks with advanced technology have been gradually developed all over the world. The resulting broadband data help to improve the seismological research. It is important to monitor the performance of broadband instruments in a new network in a long period of time to ensure the accuracy of seismic records. Here, we propose a method that uses ambient noise data in the period range 5-25 s to monitor instrument performance and check data quality in situ. The method is based on an analysis of amplitude and phase index parameters calculated from pairwise cross-correlations of three stations, which provides multiple references for reliable error estimates. Index parameters calculated daily during a two-year observation period are evaluated to identify stations with instrument response errors in near real time. During data processing, initial instrument responses are used in place of available instrument responses to simulate instrument response errors, which are then used to verify our results. We also examine feasibility of the tailing noise using data from stations selected from USArray in different locations and analyze the possible instrumental errors resulting in time-shifts used to verify the method. Additionally, we show an application that effects of instrument response errors that experience pole-zeros variations on monitoring temporal variations in crustal properties appear statistically significant velocity perturbation larger than the standard deviation. The results indicate that monitoring seismic instrument performance helps eliminate data pollution before analysis begins.
BW, Pence; Barroso, J.; Leserman, J.; Harmon, J.L.; Salahuddin, N.
2008-01-01
In the era of life-prolonging antiretroviral therapy, chronic fatigue is one of the most prevalent and disabling symptoms of people living with HIV/AIDS, yet its measurement remains challenging. No instruments have been developed specifically to describe HIV-related fatigue. We assessed the reliability and construct validity of the HIV-Related Fatigue Scale (HRFS), a 56-item self-report instrument developed through formative qualitative research and designed to measure the intensity and consequences of fatigue as well as the circumstances surrounding fatigue in people living with HIV. The HRFS has three main scales, which measure fatigue intensity, the responsiveness of fatigue to circumstances and fatigue-related impairment of functioning. The functioning scale can be further divided into subscales measuring impairment of activities of daily living, impairment of mental functioning and impairment of social functioning. Each scale demonstrated high internal consistency (Cronbach’s alpha=0.93, 0.91 and 0.97 for the intensity, responsiveness and functioning scales, respectively). The HRFS scales also demonstrated satisfactory convergent validity when compared to other fatigue measures. HIV-Related Fatigue Scales were moderately correlated with quality of nighttime sleep (rho = 0.46, 0.47 and 0.35) but showed only weak correlations with daytime sleepiness (rho = 0.20, 0.33 and 0.18). The scales were also moderately correlated with general mental and physical health as measured by the SF-36 Health Survey (rho ranged from 0.30 to 0.68 across the 8 SF-36 subscales with most >0.40). The HRFS is a promising tool to help facilitate research on the prevalence, etiology and consequences of fatigue in people living with HIV. PMID:18608084
Pence, B W; Barroso, J; Leserman, J; Harmon, J L; Salahuddin, N
2008-08-01
In the era of life-prolonging antiretroviral therapy, chronic fatigue is one of the most prevalent and disabling symptoms of people living with HIV/AIDS, yet its measurement remains challenging. No instruments have been developed specifically to describe HIV-related fatigue. We assessed the reliability and construct validity of the HIV-Related Fatigue Scale (HRFS), a 56-item self-report instrument developed through formative qualitative research and designed to measure the intensity and consequences of fatigue as well as the circumstances surrounding fatigue in people living with HIV. The HRFS has three main scales, which measure fatigue intensity, the responsiveness of fatigue to circumstances and fatigue-related impairment of functioning. The functioning scale can be further divided into subscales measuring impairment of activities of daily living, impairment of mental functioning and impairment of social functioning. Each scale demonstrated high internal consistency (Cronbach's alpha=0.93, 0.91 and 0.97 for the intensity, responsiveness and functioning scales, respectively). The HRFS scales also demonstrated satisfactory convergent validity when compared to other fatigue measures. HIV-Related Fatigue Scales were moderately correlated with quality of nighttime sleep (rho=0.46, 0.47 and 0.35) but showed only weak correlations with daytime sleepiness (rho=0.20, 0.33 and 0.18). The scales were also moderately correlated with general mental and physical health as measured by the SF-36 Health Survey (rho ranged from 0.30 to 0.68 across the 8 SF-36 subscales with most >0.40). The HRFS is a promising tool to help facilitate research on the prevalence, etiology and consequences of fatigue in people living with HIV.
Is more better than less? An analysis of children's mental health services.
Foster, E M
2000-01-01
OBJECTIVE: To assess the dose-response relationship for outpatient therapy received by children and adolescents-that is, to determine the impact of added outpatient visits on key mental health outcomes (functioning and symptomatology). DATA SOURCES/STUDY SETTING: The results presented involve analyses of data from the Fort Bragg Demonstration and are based on a sample of 301 individuals using outpatient services. STUDY DESIGN: This article provides estimates of the impact of outpatient therapy based on comparisons of individuals receiving differing treatment doses. Those comparisons involve standard multiple regression analyses as well as instrumental variables estimation. The latter provides a means of adjusting comparisons for unobserved or unmeasured differences among individuals receiving differing doses, differences that would otherwise be confounded with the impact of treatment dose. DATA COLLECTION/EXTRACTION METHODS: Using structured diagnostic interviews and behavior checklists completed by the child and his or her caretaker, detailed data on psychopathology, symptomatology, and psychosocial functioning were collected on individuals included in these analyses. Information on the use of mental health services was taken from insurance claims and a management information system. Services data were used to describe the use of outpatient therapy within the year following entry into the study. PRINCIPAL FINDINGS/CONCLUSIONS: Instrumental variables estimation indicates that added outpatient therapy improves functioning among children and adolescents. The effect is statistically significant and of moderate practical magnitude. These results imply that conventional analyses of the dose-response relationship may understate the impact of additional treatment on functioning. This finding is robust to choice of functional form, length of time over which outcomes are measured, and model specification. Dose does not appear to influence symptomatology. PMID:11130814
Computer simulation of multiple pilots flying a modern high performance helicopter
NASA Technical Reports Server (NTRS)
Zipf, Mark E.; Vogt, William G.; Mickle, Marlin H.; Hoelzeman, Ronald G.; Kai, Fei; Mihaloew, James R.
1988-01-01
A computer simulation of a human response pilot mechanism within the flight control loop of a high-performance modern helicopter is presented. A human response mechanism, implemented by a low order, linear transfer function, is used in a decoupled single variable configuration that exploits the dominant vehicle characteristics by associating cockpit controls and instrumentation with specific vehicle dynamics. Low order helicopter models obtained from evaluations of the time and frequency domain responses of a nonlinear simulation model, provided by NASA Lewis Research Center, are presented and considered in the discussion of the pilot development. Pilot responses and reactions to test maneuvers are presented and discussed. Higher level implementation, using the pilot mechanisms, are discussed and considered for their use in a comprehensive control structure.
Aversive pavlovian responses affect human instrumental motor performance.
Rigoli, Francesco; Pavone, Enea Francesco; Pezzulo, Giovanni
2012-01-01
IN NEUROSCIENCE AND PSYCHOLOGY, AN INFLUENTIAL PERSPECTIVE DISTINGUISHES BETWEEN TWO KINDS OF BEHAVIORAL CONTROL: instrumental (habitual and goal-directed) and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm), have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioral experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behavior, and psychopathology.
Aversive Pavlovian Responses Affect Human Instrumental Motor Performance
Rigoli, Francesco; Pavone, Enea Francesco; Pezzulo, Giovanni
2012-01-01
In neuroscience and psychology, an influential perspective distinguishes between two kinds of behavioral control: instrumental (habitual and goal-directed) and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm), have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioral experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behavior, and psychopathology. PMID:23060738
Suchday, Sonia; Wylie-Rosett, Judith
2014-01-01
Social support has been shown to act as a buffer for cardiovascular responses to stress. However, little is known about how social support and networks are related to cardiovascular responses to immigration stress recall. The current study evaluated the impact of structural and functional support on cardiovascular reaction following immigrant stress recall provocation as well as the moderation effect of interdependent self-construal among first-generation Chinese immigrants. One hundred fifty Chinese immigrants were recruited in the New York Chinatown area. Participants completed questionnaires assessing their levels of social support and networks, and interdependent self-construal. Following adaptation, participants recalled a recent post-immigration stress-provoking situation. Cardiovascular measures were taken during adaptation, stressor task, and recovery period. Hierarchical multiple regression analysis was performed. Social network size and type, as well as perceived emotional support were positively predictive of systolic blood pressure (SBP) reactivity changes. Instrumental support seeking was a positive predictor of SBP and diastolic blood pressure (DBP) reactivity. The moderation effect between instrumental support seeking and interdependent self-construal were significantly predictive of DBP reactivity and recovery, suggesting that perceptions about themselves in relation to others is a crucial factor for determining whether support seeking is beneficial or not. Social support was not a direct buffer on cardiovascular responses to stress among Chinese immigrants. Chinese values of interdependence and collectivism may partly explain the disconfirming results. Still, when interdependent self-construal was taken into account, Chinese immigrants who had less interdependent self-construal, but solicited more instrumental support, had faster adaptation to stress over the long term. PMID:24288021
Clinical utility of measures of breathlessness.
Cullen, Deborah L; Rodak, Bernadette
2002-09-01
The clinical utility of measures of dyspnea has been debated in the health care community. Although breathlessness can be evaluated with various instruments, the most effective dyspnea measurement tool for patients with chronic lung disease or for measuring treatment effectiveness remains uncertain. Understanding the evidence for the validity and reliability of these instruments may provide a basis for appropriate clinical application. Evaluate instruments designed to measure breathlessness, either as single-symptom or multidimensional instruments, based on psychometrics foundations such as validity, reliability, and discriminative and evaluative properties. Classification of each dyspnea measurement instrument will recommend clinical application in terms of exercise, benchmarking patients, activities of daily living, patient outcomes, clinical trials, and responsiveness to treatment. Eleven dyspnea measurement instruments were selected. Each instrument was assessed as discriminative or evaluative and then analyzed as to its psychometric properties and purpose of design. Descriptive data from all studies were described according to their primary patient application (ie, chronic obstructive pulmonary disease, asthma, or other patient populations). The Borg Scale and the Visual Analogue Scale are applicable to exertion and thus can be applied to any cardiopulmonary patient to determine dyspnea. All other measures were determined appropriate for chronic obstructive pulmonary disease, whereas the Shortness of Breath Questionnaire can be applied to cystic fibrosis and lung transplant patients. The most appropriate utility for all instruments was measuring the effects on activities of daily living and for benchmarking patient progress. Instruments that quantify function and health-related quality of life have great utility for documenting outcomes but may be limited as to documenting treatment responsiveness in terms of clinically important changes. The dyspnea measurement instruments we studied meet important standards of validity and reliability. Discriminative measures have limited clinical utility and, when used for populations or conditions for which they are not designed or validated, the data collected may not be clinically relevant. Evaluative measures have greater clinical utility and can be applied for outcome purposes. Measures should be applied to the populations and conditions for which they were designed. The relationship between clinical therapies and the measurement of dyspnea as an outcome can develop as respiratory therapists become more comfortable with implementing dyspnea measurement instruments and use the data to improve patient treatment. Dyspnea evaluation should be considered for all clinical practice guidelines and care pathways.
Rollet, S; Autischer, M; Beck, P; Latocha, M
2007-01-01
The response of a tissue equivalent proportional counter (TEPC) in a mixed radiation field with a neutron energy distribution similar to the radiation field at commercial flight altitudes has been studied. The measurements have been done at the CERN-EU High-Energy Reference Field (CERF) facility where a well-characterised radiation field is available for intercomparison. The TEPC instrument used by the ARC Seibersdorf Research is filled with pure propane gas at low pressure and can be used to determine the lineal energy distribution of the energy deposition in a mass of gas equivalent to a 2 microm diameter volume of unit density tissue, of similar size to the nuclei of biological cells. The linearity of the detector response was checked both in term of dose and dose rate. The effect of dead-time has been corrected. The influence of the detector exposure location and orientation in the radiation field on the dose distribution was also studied as a function of the total dose. The microdosimetric distribution of the absorbed dose as a function of the lineal energy has been obtained and compared with the same distribution simulated with the FLUKA Monte Carlo transport code. The dose equivalent was calculated by folding this distribution with the quality factor as a function of linear energy transfer. The comparison between the measured and simulated distributions show that they are in good agreement. As a result of this study the detector is well characterised, thanks also to the numerical simulations the instrument response is well understood, and it's currently being used onboard the aircrafts to evaluate the dose to aircraft crew caused by cosmic radiation.
Marfeo, Elizabeth E; Ni, Pengsheng; Chan, Leighton; Rasch, Elizabeth K; Jette, Alan M
2014-07-01
The goal of this article was to investigate optimal functioning of using frequency vs. agreement rating scales in two subdomains of the newly developed Work Disability Functional Assessment Battery: the Mood & Emotions and Behavioral Control scales. A psychometric study comparing rating scale performance embedded in a cross-sectional survey used for developing a new instrument to measure behavioral health functioning among adults applying for disability benefits in the United States was performed. Within the sample of 1,017 respondents, the range of response category endorsement was similar for both frequency and agreement item types for both scales. There were fewer missing values in the frequency items than the agreement items. Both frequency and agreement items showed acceptable reliability. The frequency items demonstrated optimal effectiveness around the mean ± 1-2 standard deviation score range; the agreement items performed better at the extreme score ranges. Findings suggest an optimal response format requires a mix of both agreement-based and frequency-based items. Frequency items perform better in the normal range of responses, capturing specific behaviors, reactions, or situations that may elicit a specific response. Agreement items do better for those whose scores are more extreme and capture subjective content related to general attitudes, behaviors, or feelings of work-related behavioral health functioning. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1979-01-01
The results of the Coastal Zone Color Scanner protoflight tests are examined in detail while some of the test results are evaluated with respect to expected performance. Performance characteristics examined include spectral response, signal to noise ratio as a function of radiance input, radiance response, the modulation transfer function, and the field of view and coregistration. The results of orbital sequence tests are also included. The in orbit performance or return of radiometric data in the six spectral bands is evaluated along with the data processing sequence necessary to derive the final data products. Examples of the raw data are given and the housekeeping or diagnostic data which provides information on the day to day health or status of the instrument are discussed.
Adams, Catherine A; Murdoch, Jennifer L; Consiglio, Maria C; Williams, Daniel M
2007-07-01
One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots' subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness (SA) over conventional instrument flight rules (IFR) procedures.
Earth observing system instrument pointing control modeling for polar orbiting platforms
NASA Technical Reports Server (NTRS)
Briggs, H. C.; Kia, T.; Mccabe, S. A.; Bell, C. E.
1987-01-01
An approach to instrument pointing control performance assessment for large multi-instrument platforms is described. First, instrument pointing requirements and reference platform control systems for the Eos Polar Platforms are reviewed. Performance modeling tools including NASTRAN models of two large platforms, a modal selection procedure utilizing a balanced realization method, and reduced order platform models with core and instrument pointing control loops added are then described. Time history simulations of instrument pointing and stability performance in response to commanded slewing of adjacent instruments demonstrates the limits of tolerable slew activity. Simplified models of rigid body responses are also developed for comparison. Instrument pointing control methods required in addition to the core platform control system to meet instrument pointing requirements are considered.
Ward, Irene; Pivko, Susan; Brooks, Gary; Parkin, Kate
2011-11-01
To demonstrate sensitivity to change of the Stroke Rehabilitation Assessment of Movement (STREAM) as well as the concurrent and predictive validity of the STREAM in an acute rehabilitation setting. Prospective cohort study. Acute, in-patient rehabilitation department within a tertiary-care teaching hospital in the United States. Thirty adults with a newly diagnosed, first ischemic stroke. Clinical assessments were conducted on admission and then again on discharge from the rehabilitation hospital with the STREAM (total STREAM and upper extremity, lower extremity, and mobility subscales), Functional Independence Measure (FIM), and Stroke Impact Scale-16 (SIS-16). Sensitivity to change was determined with the Wilcoxon signed rank test and by the calculation of standardized response means. Spearman correlations were used to assess concurrent validity of the total STREAM and STREAM subscales with the FIM and SIS-16 on admission and discharge. We determined predictive validity for all instruments by correlating admission scores with actual and predicted length of stay and by testing associations between admission scores and discharge destination (home vs subacute facility). Not applicable. For all instruments, there was statistically significant improvement from admission to discharge. The standardized response means for the total STREAM and STREAM subscales were large. Spearman correlations between the total STREAM and STREAM subscales and the FIM and SIS-16 were moderate to excellent, both on admission and discharge. Among change scores, only the SIS-16 correlated with the total STREAM. All 3 instruments were significantly associated with discharge destination; however, the associations were strongest for the total STREAM and STREAM subscales. All instruments showed moderate-to-excellent correlations with predicted and actual length of stay. The STREAM is sensitive to change and demonstrates good concurrent and predictive validity as compared with the FIM and SIS-16 in the acute inpatient rehabilitation population. Copyright © 2011 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Use of the late-life function and disability instrument to assess disability in major depression.
Karp, Jordan F; Skidmore, Elizabeth; Lotz, Meredith; Lenze, Eric; Dew, Mary Amanda; Reynolds, Charles F
2009-09-01
To determine whether there was greater disability in subjects with depression than in those without, the correlation between disability and depression severity and quality of life, and whether improvement in disability after antidepressant pharmacotherapy was greater in those who responded to antidepressant treatment. Disability in subjects with and without depression from two different studies was compared for 22 weeks. Correlations were performed for the subjects with depression between disability and depression, anxiety, health-related quality of life (HRQOL), and medical comorbidity. T-tests were used to compare disability between subjects who did and did not respond to antidepressant treatment and change in disability after pharmacotherapy. Late-life depression research clinic. The 313 subjects were recruited from primary care and the community and were aged 60 and older; 244 subjects were participants in a depression treatment protocol, and 69 subjects without depression participated in a separate longitudinal observational study of the mental and cognitive health of depression-free older adults. The Late-Life Function and Disability Instrument (LL-FDI), a measure of instrumental activity of daily living, personal role, and social role functioning. Subjects with depression scored lower than controls for domains measuring limitation (can do) and frequency (does do) of activities. Both disability domains correlated with depression severity, anxiety, HRQOL, and cognition. Disability improved with antidepressant treatment; for partial responders who continued to receive higher-dose antidepressant treatment out to 22 weeks, there was continued improvement, although not to the level of comparison subjects without depression. The LL-FDI appears to discriminate subjects with depression from those without, correlates with depression severity, and demonstrates sensitivity to antidepressant treatment response. We recommend further investigation of the LL-FDI and similar disability instruments for assessing depression-related disability.
NASA Technical Reports Server (NTRS)
Vostreys, R. W.
1981-01-01
Sounding rockets, artificial Earth satellites, and space probes launched betweeen January 1 and December 31, 1980 are listed. Data tabulated for the rocket launchings show launching site, instruments carried, date of launch, agency rocket identification, sponsoring country, experiment discipline, peak altitude, and the experimenter or institution responsible. Tables for satellites and space probes show COSPAR designation, spacecraft name, country, launch date, epoch date, orbit type, apoapsis, periapsis and inclination period. The functions and responsibilities of the World Data Center and the areas of scientific interest at the seven subcenters are defined. An alphabetical listing of experimenters using the sounding rockets is also provided.
Farmery, A D; Hahn, C E
2000-08-01
Tidal ventilation gas-exchange models in respiratory physiology and medicine not only require solution of mass balance equations breath-by-breath but also may require within-breath measurements, which are instantaneous functions of time. This demands a degree of temporal resolution and fidelity of integration of gas flow and concentration signals that cannot be provided by most clinical gas analyzers because of their slow response times. We have characterized the step responses of the Datex Ultima (Datex Instrumentation, Helsinki, Finland) gas analyzer to oxygen, carbon dioxide, and nitrous oxide in terms of a Gompertz four-parameter sigmoidal function. By inversion of this function, we were able to reduce the rise times for all these gases almost fivefold, and, by its application to real on-line respiratory gas signals, it is possible to achieve a performance comparable to the fastest mass spectrometers. With the use of this technique, measurements required for non-steady-state and tidal gas-exchange models can be made easily and reliably in the clinical setting.
Donati, Maria Anna; Chiesi, Francesca; Izzo, Viola A; Primi, Caterina
2017-01-01
As there is a lack of evidence attesting the equivalent item functioning across genders for the most employed instruments used to measure pathological gambling in adolescence, the present study was aimed to test the gender invariance of the Gambling Behavior Scale for Adolescents (GBS-A), a new measurement tool to assess the severity of Gambling Disorder (GD) in adolescents. The equivalence of the items across genders was assessed by analyzing Differential Item Functioning within an Item Response Theory framework. The GBS-A was administered to 1,723 adolescents, and the graded response model was employed. The results attested the measurement equivalence of the GBS-A when administered to male and female adolescent gamblers. Overall, findings provided evidence that the GBS-A is an effective measurement tool of the severity of GD in male and female adolescents and that the scale was unbiased and able to relieve truly gender differences. As such, the GBS-A can be profitably used in educational interventions and clinical treatments with young people.
Auditory evoked functions in ground crew working in high noise environment of Mumbai airport.
Thakur, L; Anand, J P; Banerjee, P K
2004-10-01
The continuous exposure to the relatively high level of noise in the surroundings of an airport is likely to affect the central pathway of the auditory system as well as the cognitive functions of the people working in that environment. The Brainstem Auditory Evoked Responses (BAER), Mid Latency Response (MLR) and P300 response of the ground crew employees working in Mumbai airport were studied to evaluate the effects of continuous exposure to high level of noise of the surroundings of the airport on these responses. BAER, P300 and MLR were recorded by using a Nicolet Compact-4 (USA) instrument. Audiometry was also monitored with the help of GSI-16 Audiometer. There was a significant increase in the peak III latency of the BAER in the subjects exposed to noise compared to controls with no change in their P300 values. The exposed group showed hearing loss at different frequencies. The exposure to the high level of noise caused a considerable decline in the auditory conduction upto the level of the brainstem with no significant change in conduction in the midbrain, subcortical areas, auditory cortex and associated areas. There was also no significant change in cognitive function as measured by P300 response.
Lesher, Danielle Ann-Marie; Mulcahey, M J; Hershey, Peter; Stanton, Donna Breger; Tiedgen, Andrea C
We sought to identify outcome instruments used in rehabilitation of the hand and upper extremity; to determine their alignment with the constructs of the International Classification of Functioning, Disability and Health (ICF) and the Occupational Therapy Practice Framework: Domain and Process; and to report gaps in the constructs measured by outcome instruments as a basis for future research. We searched CINAHL, MEDLINE, OTseeker, and the Cochrane Central Register of Controlled Trials using scoping review methodology and evaluated outcome instruments for concordance with the ICF and the Framework. We identified 18 outcome instruments for analysis. The findings pertain to occupational therapists' focus on body functions, body structures, client factors, and activities of daily living; a gap in practice patterns in use of instruments; and overestimation of the degree to which instruments used are occupationally based. Occupational therapy practitioners should use outcome instruments that embody conceptual frameworks for classifying function and activity. Copyright © 2017 by the American Occupational Therapy Association, Inc.
Performance assessment of FY-3C/MERSI on early orbit
NASA Astrophysics Data System (ADS)
Hu, Xiuqing; Xu, Na; Wu, Ronghua; Chen, Lin; Min, Min; Wang, Ling; Xu, Hanlie; Sun, Ling; Yang, Zhongdong; Zhang, Peng
2014-11-01
FY-3C/MERSI has some remarkable improvements compared to the previous MERSIs including better spectral response function (SRF) consistency of different detectors within one band, increasing the capability of lunar observation by space view (SV) and the improvement of radiometric response stability of solar bands. During the In-orbit verification (IOV) commissioning phase, early results that indicate the MERSI representative performance were derived, including the signal noise ratio (SNR), dynamic range, MTF, B2B registration, calibration bias and instrument stability. The SNRs at the solar bands (Bands 1-4 and 6-20) was largely beyond the specifications except for two NIR bands. The in-flight calibration and verification for these bands are also heavily relied on the vicarious techniques such as China radiometric calibration sites(CRCS), cross-calibration, lunar calibration, DCC calibration, stability monitoring using Pseudo Invariant Calibration Sites (PICS) and multi-site radiance simulation. This paper will give the results of the above several calibration methods and monitoring the instrument degradation in early on-orbit time.
Formisano, Rita; D’Ippolito, Mariagrazia; Risetti, Monica; Riccio, Angela; Caravasso, Chiara Falletta; Catani, Sheila; Rizza, Federica; Forcina, Antonio; Buzzi, Maria Gabriella
Summary The aim of this study was to review the usefulness of clinical and instrumental evaluation in individuals with disorders of consciousness (DOC). Thirteen subjects with severe acquired brain injury (ABI) and a diagnosis of DOC were evaluated using the Coma Recovery Scale in its revised version (CRS-R) and a new global disability index, the Post-Coma Scale (PCS). These instruments were administered both by a neutral examiner (professional) and by a professional in the presence of a caregiver. All patients were also scored using the International Classification of Functioning, Disability and Health (ICF). A statistically significant correlation between CRS-R and PCS was demonstrated. However, there also emerged significant differences in responsiveness between professional versus caregiver+professional assessment using the two scales. The emotional stimulation provided by significant others (caregivers) during administration of DOC evaluation scales may improve the assessment of responsiveness. PMID:21693084
Reinforcement and substitution in humans: a multiple-response analysis1
Bernstein, Daniel J.; Ebbesen, Ebbe B.
1978-01-01
Three adult human subjects engaged in activities such as reading, sewing, artwork, and candlemaking while living alone in a laboratory apartment 24 hours per day for several weeks. After a baseline period in which the activities were fully available, access to a particular activity (contingent response) was made dependent on engaging in another less-preferred activity (instrumental response). The contingencies produced substantial increases in instrumental responding, and responding decreased toward baseline levels when the dependency was removed. Under the contingent conditions, time earned for the concurrent activity was always less than the baseline level. To determine the contribution of this reduction to the instrumental increase, access to the contingent activity was restricted in the absence of any dependency. The results indicated that increases among responses that filled the newly available time could be selective, e.g., artwork increased when reading was restricted but candlemaking did not. It was concluded that the reductions in the contingent response that accompany contingencies usually do not exclusively determine instrumental increases, but selective increases can contribute to the increase in time devoted to the instrumental response. PMID:16812105
Measuring the dependence of the decay curve on the electron energy deposit in NaI(Tl)
NASA Astrophysics Data System (ADS)
Choong, W.-S.; Bizarri, G.; Cherepy, N. J.; Hull, G.; Moses, W. W.; Payne, S. A.
2011-08-01
We report on the first measurement of the decay times of NaI(Tl) as a function of the deposited electron energy. It has been suggested that the decay curve depends on the ionization density, which is correlated with the electron energy deposit in the scintillator. The ionization creates excitation states, which can decay radiatively and non-radiatively through a number of competing processes. As a result, the rate at which the excitation decays depends on the ionization density. A measurement of the decay curve as a function of the ionization density will allow us to probe the kinetic rates of the competing processes. The Scintillator Light Yield Non-proportionality Characterization Instrument (SLYNCI) measures the electron response of scintillators utilizing fast sampling ADCs to digitize the raw signals from the detectors, and so can provide a measurement of the light pulse shape from the scintillator. Using data collected with the SLYNCI instrument, the intrinsic scintillation profile is extracted on an event-by-event basis by deconvolving the raw signal with the impulse response of the system. Scintillation profiles with the same electron energy deposit are summed to obtain decay curves as a function of the deposited electron energy. The decay time constants are obtained by fitting the decay curves with a two-component exponential decay. While a slight dependence of the decay time constants on the electron energy deposit is observed, the results are not statistically significant.
MAISIE: a multipurpose astronomical instrument simulator environment
NASA Astrophysics Data System (ADS)
O'Brien, Alan; Beard, Steven; Geers, Vincent; Klaassen, Pamela
2016-07-01
Astronomical instruments often need simulators to preview their data products and test their data reduction pipelines. Instrument simulators have tended to be purpose-built with a single instrument in mind, and at- tempting to reuse one of these simulators for a different purpose is often a slow and difficult task. MAISIE is a simulator framework designed for reuse on different instruments. An object-oriented design encourages reuse of functionality and structure, while offering the flexibility to create new classes with new functionality. MAISIE is a set of Python classes, interfaces and tools to help build instrument simulators. MAISIE can just as easily build simulators for single and multi-channel instruments, imagers and spectrometers, ground and space based instruments. To remain easy to use and to facilitate the sharing of simulators across teams, MAISIE is written in Python, a freely available and open-source language. New functionality can be created for MAISIE by creating new classes that represent optical elements. This approach allows new and novel instruments to add functionality and take advantage of the existing MAISIE classes. MAISIE has recently been used successfully to develop the simulator for the JWST/MIRI- Medium Resolution Spectrometer.
Burgess, Philip M; Harris, Meredith G; Coombs, Tim; Pirkis, Jane E
2017-04-01
Functioning is one of the key domains emphasised in the routine assessment of outcomes that has been occurring in specialised public sector mental health services across Australia since 2002, via the National Outcomes and Casemix Collection. For adult consumers (aged 18-64), the 16-item Life Skills Profile (LSP-16) has been the instrument of choice to measure functioning. However, review of the National Outcomes and Casemix Collection protocol has highlighted some limitations to the current approach to measuring functioning. A systematic review was conducted to identify, against a set of pre-determined criteria, the most suitable existing clinician-rated instruments for the routine measurement of functioning for adult consumers. We used two existing reviews of functioning measures as our starting point and conducted a search of MEDLINE and PsycINFO to identify articles relating to additional clinician-rated instruments. We evaluated identified instruments using a hierarchical, criterion-based approach. The criteria were as follows: (1) is brief (<50 items) and simple to score, (2) is not made redundant by more recent instruments, (3) relevant version has been scientifically scrutinised, (4) considers functioning in a contemporary way and (5) demonstrates sound psychometric properties. We identified 20 relevant instruments, 5 of which met our criteria: the LSP-16, the Health of the Nation Outcome Scales, the Illness Management and Recovery Scale-Clinician Version, the Multnomah Community Ability Scale and the Personal and Social Performance Scale. Further work is required to determine which, if any, of these instruments satisfy further criteria relating to their appropriateness for assessing functioning within relevant service contexts, acceptability to clinicians and consumers, and feasibility in routine practice. This should involve seeking stakeholders' opinions (e.g. about the specific domains of functioning covered by each instrument and the language used in individual items) and testing completion rates in busy service settings.
The Cherenkov Telescope Array production system for Monte Carlo simulations and analysis
NASA Astrophysics Data System (ADS)
Arrabito, L.; Bernloehr, K.; Bregeon, J.; Cumani, P.; Hassan, T.; Haupt, A.; Maier, G.; Moralejo, A.; Neyroud, N.; pre="for the"> CTA Consortium, 2017-10-01 The Cherenkov Telescope Array (CTA), an array of many tens of Imaging Atmospheric Cherenkov Telescopes deployed on an unprecedented scale, is the next-generation instrument in the field of very high energy gamma-ray astronomy. An average data stream of about 0.9 GB/s for about 1300 hours of observation per year is expected, therefore resulting in 4 PB of raw data per year and a total of 27 PB/year, including archive and data processing. The start of CTA operation is foreseen in 2018 and it will last about 30 years. The installation of the first telescopes in the two selected locations (Paranal, Chile and La Palma, Spain) will start in 2017. In order to select the best site candidate to host CTA telescopes (in the Northern and in the Southern hemispheres), massive Monte Carlo simulations have been performed since 2012. Once the two sites have been selected, we have started new Monte Carlo simulations to determine the optimal array layout with respect to the obtained sensitivity. Taking into account that CTA may be finally composed of 7 different telescope types coming in 3 different sizes, many different combinations of telescope position and multiplicity as a function of the telescope type have been proposed. This last Monte Carlo campaign represented a huge computational effort, since several hundreds of telescope positions have been simulated, while for future instrument response function simulations, only the operating telescopes will be considered. In particular, during the last 18 months, about 2 PB of Monte Carlo data have been produced and processed with different analysis chains, with a corresponding overall CPU consumption of about 125 M HS06 hours. In these proceedings, we describe the employed computing model, based on the use of grid resources, as well as the production system setup, which relies on the DIRAC interware. Finally, we present the envisaged evolutions of the CTA production system for the off-line data processing during CTA operations and the instrument response function simulations.
Wen, Weiping; Kalkan, Erol
2017-01-01
Deconvolution and cross‐correlation techniques are used for system identification of a 20‐story steel, moment‐resisting frame building in downtown Anchorage, Alaska. This regular‐plan midrise structure is instrumented with a 32‐channel accelerometer array at 10 levels. The impulse response functions (IRFs) and correlation functions (CFs) are computed based on waveforms recorded from ambient vibrations and five local and regional earthquakes. The earthquakes occurred from 2005 to 2014 with moment magnitudes between 4.7 and 6.2 over a range of azimuths at epicenter distances of 13.3–183 km. The building’s fundamental frequencies and mode shapes are determined using a complex mode indicator function based on singular value decomposition of multiple reference frequency‐response functions. The traveling waves, identified in IRFs with a virtual source at the roof, and CFs are used to estimate the intrinsic attenuation associated with the fundamental modes and shear‐wave velocity in the building. Although the cross correlation of the waveforms at various levels with the corresponding waveform at the first floor provides more complicated wave propagation than that from the deconvolution with virtual source at the roof, the shear‐wave velocities identified by both techniques are consistent—the largest difference in average values is within 8%. The median shear‐wave velocity from the IRFs of five earthquakes is 191 m/s for the east–west (E‐W), 205 m/s for the north–south (N‐S), and 176 m/s for the torsional responses. The building’s average intrinsic‐damping ratio is estimated to be 3.7% and 3.4% in the 0.2–1 Hz frequency band for the E‐W and N‐S directions, respectively. These results are intended to serve as reference for the undamaged condition of the building, which may be used for tracking changes in structural integrity during and after future earthquakes.
GPS Radiation Measurements: Instrument Modeling and Simulation (Project w14_gpsradiation)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, John P.
The following topics are covered: electron response simulations and typical calculated response. Monte Carlo calculations of the response of future charged particle instruments (dosimeters) intended to measure the flux of charged particles in space were performed. The electron channels are called E1- E11 – each of which is intended to detect a different range of electron energies. These instruments are on current and future GPS satellites.
NASA Technical Reports Server (NTRS)
Barnes, Robert A.; Brown, Steven W.; Lykke, Keith R.; Guenther, Bruce; Butler, James J.; Schwarting, Thomas; Turpie, Kevin; Moyer, David; DeLuccia, Frank; Moeller, Christopher
2015-01-01
Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance responsivity in a two-step method. In the first step, the relative spectral response (RSR) of the instrument is determined using a nearly monochromatic light source such as a lamp-illuminated monochromator. These sources do not typically fill the field-of-view of the instrument nor act as calibrated sources of light. Consequently, they only provide a relative (not absolute) spectral response for the instrument. In the second step, the instrument views a calibrated source of broadband light, such as a lamp-illuminated integrating sphere. The RSR and the sphere absolute spectral radiance are combined to determine the absolute spectral radiance responsivity (ASR) of the instrument. More recently, a full-aperture absolute calibration approach using widely tunable monochromatic lasers has been developed. Using these sources, the ASR of an instrument can be determined in a single step on a wavelength-by-wavelength basis. From these monochromatic ASRs, the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as lamp-illuminated integrating spheres. In this work, the traditional broadband source-based calibration of the Suomi National Preparatory Project (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) sensor is compared with the laser-based calibration of the sensor. Finally, the impact of the new full-aperture laser-based calibration approach on the on-orbit performance of the sensor is considered.
Barnes, Robert A.; Brown, Steven W.; Lykke, Keith R.; Guenther, Bruce; Butler, James J.; Schwarting, Thomas; Moyer, David; Turpie, Kevin; DeLuccia, Frank; Moeller, Christopher
2016-01-01
Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance responsivity in a two-step method. In the first step, the relative spectral response (RSR) of the instrument is determined using a nearly monochromatic light source such as a lamp-illuminated monochromator. These sources do not typically fill the field-of-view of the instrument nor act as calibrated sources of light. Consequently, they only provide a relative (not absolute) spectral response for the instrument. In the second step, the instrument views a calibrated source of broadband light, such as a lamp-illuminated integrating sphere. The RSR and the sphere absolute spectral radiance are combined to determine the absolute spectral radiance responsivity (ASR) of the instrument. More recently, a full-aperture absolute calibration approach using widely tunable monochromatic lasers has been developed. Using these sources, the ASR of an instrument can be determined in a single step on a wavelength-by-wavelength basis. From these monochromatic ASRs, the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as integrating spheres. In this work, the traditional broadband source-based calibration of the Suomi National Preparatory Project (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) sensor is compared with the laser-based calibration of the sensor. Finally, the impact of the new full-aperture laser-based calibration approach on the on-orbit performance of the sensor is considered. PMID:26836861
Paule, Merle G; Green, Leonard; Myerson, Joel; Alvarado, Maria; Bachevalier, Jocelyne; Schneider, Jay S; Schantz, Susan L
2012-03-01
A variety of behavioral instruments are available for assessing important aspects of cognition in both animals and humans and, in many cases, the same instruments can be used in both. While nonhuman primates are phylogenetically closest to humans, rodents, pigeons and other animals also offer behaviors worthy of note. Delay Discounting procedures are as useful as any in studies of impulsivity and may have utility in shedding light on processes associated with drug abuse. Specific memory tests such as Visual Paired Comparisons tasks (similar to the Fagan test of infant intelligence) can be modified to allow for assessment of different aspects of memory such as spatial memory. Use of these and other specific memory tasks can be used to directly monitor aspects of cognitive development in infant animals, particularly in nonhuman primates such as monkeys, and children and to draw inferences with respect to possible neuroanatomical substrates sub-serving their functions. Tasks for assessing working memory such as Variable Delayed Response (VDR), modified VDR and Spatial Working Memory tasks are now known to be affected in Parkinson's disease (PD). These and other cognitive function tasks are being used in a monkey model of PD to assess the ability of anti-Parkinson's disease therapies to ameliorate these cognitive deficits without diminishing their therapeutic effects on motor dysfunction. Similarly, in a rat model of the cognitive deficits associated with perinatal exposure to polychlorinated biphenyls (PCBs), clear parallels with children can be seen in at least two areas of executive function: cognitive flexibility and response inhibition. In the rat model, discrimination reversal tasks were utilized to assess cognitive flexibility, a function often assessed in humans using the Wisconsin Card Sorting Task. Response inhibition was assessed using performance in a Differential Reinforcement of Low Response Rates (DRL) task. As the data continue to accumulate, it becomes more clear that our attempts to adapt animal-appropriate tasks for the study of important aspects of human cognition have proven to be very fruitful. Published by Elsevier Inc.
10 CFR 55.41 - Written examination: Operators.
Code of Federal Regulations, 2013 CFR
2013-01-01
... elements, control rods, core instrumentation, and coolant flow. (3) Mechanical components and design..., and functions of reactivity control mechanisms and instrumentation. (7) Design, components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and...
10 CFR 55.41 - Written examination: Operators.
Code of Federal Regulations, 2014 CFR
2014-01-01
... elements, control rods, core instrumentation, and coolant flow. (3) Mechanical components and design..., and functions of reactivity control mechanisms and instrumentation. (7) Design, components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and...
Eriks-Hoogland, Inge E; Brinkhof, Martin W G; Al-Khodairy, Abdul; Baumberger, Michael; Brechbühl, Jörg; Curt, Armin; Mäder, Mark; Stucki, Gerold; Post, Marcel W M
2011-11-01
The aims of this study were to provide a selection of biomedical domains based on the comprehensive International Classification of Functioning, Disability, and Health (ICF) core sets for spinal cord injury (SCI) and to present an overview of the corresponding measurement instruments. Based on the Biomedical Domain Set, the SCI literature, the International Spinal Cord Society international data sets, and the Spinal Cord Injury Rehabilitation Evidence project publications were used to derive category specifications for use in SCI research. Expert opinion was used to derive a priority selection. The same sources were used to determine candidate measurement instruments for the specification of body functions and body structures using an example, and guiding principles were applied to select the most appropriate biomedical measurement instrument(s) for use in an SCI research project. Literature searches were performed for 41 second-level ICF body functions categories and for four second-level ICF body structures categories. For some of these categories, only a few candidate measurement instruments were found with limited variation in the type of measurement instruments. An ICF-based measurement set for biomedical aspects of functioning with SCI was established. For some categories of the ICF core sets for SCI, there is a need to develop measurement instruments.
Measurement equivalence and differential item functioning in family psychology.
Bingenheimer, Jeffrey B; Raudenbush, Stephen W; Leventhal, Tama; Brooks-Gunn, Jeanne
2005-09-01
Several hypotheses in family psychology involve comparisons of sociocultural groups. Yet the potential for cross-cultural inequivalence in widely used psychological measurement instruments threatens the validity of inferences about group differences. Methods for dealing with these issues have been developed via the framework of item response theory. These methods deal with an important type of measurement inequivalence, called differential item functioning (DIF). The authors introduce DIF analytic methods, linking them to a well-established framework for conceptualizing cross-cultural measurement equivalence in psychology (C.H. Hui and H.C. Triandis, 1985). They illustrate the use of DIF methods using data from the Project on Human Development in Chicago Neighborhoods (PHDCN). Focusing on the Caregiver Warmth and Environmental Organization scales from the PHDCN's adaptation of the Home Observation for Measurement of the Environment Inventory, the authors obtain results that exemplify the range of outcomes that may result when these methods are applied to psychological measurement instruments. (c) 2005 APA, all rights reserved
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
NASA Astrophysics Data System (ADS)
Lind, Johan U.; Busbee, Travis A.; Valentine, Alexander D.; Pasqualini, Francesco S.; Yuan, Hongyan; Yadid, Moran; Park, Sung-Jin; Kotikian, Arda; Nesmith, Alexander P.; Campbell, Patrick H.; Vlassak, Joost J.; Lewis, Jennifer A.; Parker, Kevin K.
2017-03-01
Biomedical research has relied on animal studies and conventional cell cultures for decades. Recently, microphysiological systems (MPS), also known as organs-on-chips, that recapitulate the structure and function of native tissues in vitro, have emerged as a promising alternative. However, current MPS typically lack integrated sensors and their fabrication requires multi-step lithographic processes. Here, we introduce a facile route for fabricating a new class of instrumented cardiac microphysiological devices via multimaterial three-dimensional (3D) printing. Specifically, we designed six functional inks, based on piezo-resistive, high-conductance, and biocompatible soft materials that enable integration of soft strain gauge sensors within micro-architectures that guide the self-assembly of physio-mimetic laminar cardiac tissues. We validated that these embedded sensors provide non-invasive, electronic readouts of tissue contractile stresses inside cell incubator environments. We further applied these devices to study drug responses, as well as the contractile development of human stem cell-derived laminar cardiac tissues over four weeks.
Trask, Sydney; Thrailkill, Eric A; Bouton, Mark E
2017-04-01
An occasion setter is a stimulus that modulates the ability of another stimulus to control behavior. A rich history of experimental investigation has identified several important properties that define occasion setters and the conditions that give rise to occasion setting. In this paper, we first consider the basic hallmarks of occasion setting in Pavlovian conditioning. We then review research that has examined the mechanisms underlying the crucial role of context in Pavlovian and instrumental extinction. In Pavlovian extinction, evidence suggests that the extinction context can function as a negative occasion setter whose role is to disambiguate the current meaning of the conditioned stimulus; the conditioning context can also function as a positive occasion setter. In operant extinction, in contrast, the extinction context may directly inhibit the response, and the conditioning context can directly excite it. We outline and discuss the key results supporting these distinctions. Copyright © 2016 Elsevier B.V. All rights reserved.
Arias González, Víctor B; Crespo Sierra, María Teresa; Arias Martínez, Benito; Martínez-Molina, Agustín; Ponce, Fernando P
2015-09-23
The Connor-Davidson Resilience Scale (CD-RISC) is inarguably one of the best-known instruments in the field of resilience assessment. However, the criteria for the psychometric quality of the instrument were based only on classical test theory. The aim of this paper has focused on the calibration of the CD-RISC with a nonclinical sample of 444 adults using the Rasch-Andrich Rating Scale Model, in order to clarify its structure and analyze its psychometric properties at the level of item. Two items showed misfit to the model and were eliminated. The remaining 22 items form basically a unidimensional scale. The CD-RISC has good psychometric properties. The fit of both the items and the persons to the Rasch model was good, and the response categories were functioning properly. Two of the items showed differential item functioning. The CD-RISC has an obvious ceiling effect, which suggests to include more difficult items in future versions of the scale.
Towards an Analogue Neuromorphic VLSI Instrument for the Sensing of Complex Odours
NASA Astrophysics Data System (ADS)
Ab Aziz, Muhammad Fazli; Harun, Fauzan Khairi Che; Covington, James A.; Gardner, Julian W.
2011-09-01
Almost all electronic nose instruments reported today employ pattern recognition algorithms written in software and run on digital processors, e.g. micro-processors, microcontrollers or FPGAs. Conversely, in this paper we describe the analogue VLSI implementation of an electronic nose through the design of a neuromorphic olfactory chip. The modelling, design and fabrication of the chip have already been reported. Here a smart interface has been designed and characterised for thisneuromorphic chip. Thus we can demonstrate the functionality of the a VLSI neuromorphic chip, producing differing principal neuron firing patterns to real sensor response data. Further work is directed towards integrating 9 separate neuromorphic chips to create a large neuronal network to solve more complex olfactory problems.
A novel instrumentation circuit for electrochemical measurements.
Yin, Li-Te; Wang, Hung-Yu; Lin, Yang-Chiuan; Huang, Wen-Chung
2012-01-01
In this paper, a novel signal processing circuit which can be used for the measurement of H(+) ion and urea concentration is presented. A potentiometric method is used to detect the concentrations of H(+) ions and urea by using H(+) ion-selective electrodes and urea electrodes, respectively. The experimental data shows that this measuring structure has a linear pH response for the concentration range within pH 2 and 12, and the dynamic range for urea concentration measurement is in the range of 0.25 to 64 mg/dL. The designed instrumentation circuit possesses a calibration function and it can be applied to different sensing electrodes for electrochemical analysis. It possesses the advantageous properties of being multi-purpose, easy calibration and low cost.
Calibration Challenges and Improvements for Terra and Aqua MODIS Level-1B Data Product Qualit
NASA Astrophysics Data System (ADS)
Xiong, X.; Angal, A.; Chen, H.; Geng, X.; Li, Y.; Link, D.; Salomonson, V.; Twedt, K.; Wang, Z.; Wilson, T.; Wu, A.
2017-12-01
Terra and Aqua MODIS instruments launched in 1999 and 2002, respectively, have provided the remote sensing community and users worldwide a series of high quality long-term data records. They have enabled a broad range of scientific studies of the Earth's system and changes in its key geophysical and environmental parameters. To date, both MODIS instruments continue to operate nominally with all on-board calibrators (OBC) functioning properly. MODIS reflective solar bands (RSB) are currently calibrated by a solar diffuser (SD) and solar diffuser stability monitor (SDSM) system, coupled with regularly scheduled lunar observations and trending results from selected ground reference targets. The thermal emissive bands (TEB) calibration is performed using an on-board blackbody (BB) on a scan-by-scan basis. The sensor's spectral and spatial characteristics are periodically tracked by the on-board spectroradiometric calibration assembly (SRCA). On-orbit changes in sensor responses or performance characteristics, often in non-deterministic ways, underscore the need for dedicated calibration efforts to be made over the course of the sensor's entire mission. For MODIS instruments, this task has been undertaken by the MODIS Characterization Support Team (MCST). In this presentation, we provide an overview of MODIS instrument operation and calibration activities with a focus on recent challenging issues. We describe the efforts made and methodologies developed to address various challenging issues, including on-orbit characterization of sensor response versus scan angle (RVS) and polarization sensitives in the reflective solar spectral region, and electronic crosstalk impact on sensor calibration. Also discussed are the latest improvements made into the MODIS Level-1B data products as well as lessons that could benefit other instruments (e.g. VIIRS) for their on-orbit calibration and characterization.
Lima, Elaine; Teixeira-Salmela, Luci F; Simões, Luan; Guerra, Ana C C; Lemos, Andrea
2016-03-15
While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.
Lima, Elaine; Teixeira-Salmela, Luci F.; Simões, Luan; Guerra, Ana C. C.; Lemos, Andrea
2016-01-01
Background While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. Objective To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Method Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. Results A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. Conclusion The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed. PMID:26982452
de Paula, Jonas J.; Diniz, Breno S.; Bicalho, Maria A.; Albuquerque, Maicon Rodrigues; Nicolato, Rodrigo; de Moraes, Edgar N.; Romano-Silva, Marco A.; Malloy-Diniz, Leandro F.
2015-01-01
Cognitive functioning influences activities of daily living (ADL). However, studies reporting the association between ADL and neuropsychological performance show inconsistent results regarding what specific cognitive domains are related to each specific functional domains. Additionally, whether depressive symptoms are associated with a worse functional performance in older adults is still under explored. We investigated if specific cognitive domains and depressive symptoms would affect different aspects of ADL. Participants were 274 older adults (96 normal aging participants, 85 patients with mild cognitive impairment, and 93 patients probable with mild Alzheimer’s disease dementia) with low formal education (∼4 years). Measures of ADL included three complexity levels: Self-care, Instrumental-Domestic, and Instrumental-Complex. The specific cognitive functions were evaluated through a factorial strategy resulting in four cognitive domains: Executive Functions, Language/Semantic Memory, Episodic Memory, and Visuospatial Abilities. The Geriatric Depression Scale measured depressive symptoms. Multiple linear regression analysis showed executive functions and episodic memory as significant predictors of Instrumental-Domestic ADL, and executive functions, episodic memory and language/semantic memory as predictors of Instrumental-Complex ADL (22 and 28% of explained variance, respectively). Ordinal regression analysis showed the influence of specific cognitive functions and depressive symptoms on each one of the instrumental ADL. We observed a heterogeneous pattern of association with explained variance ranging from 22 to 38%. Different instrumental ADL had specific cognitive predictors and depressive symptoms were predictive of ADL involving social contact. Our results suggest a specific pattern of influence depending on the specific instrumental daily living activity. PMID:26257644
Baylor, Carolyn; Yorkston, Kathryn; Eadie, Tanya; Kim, Jiseon; Chung, Hyewon; Amtmann, Dagmar
2015-01-01
Purpose The purpose of this study was to calibrate the items for the Communicative Participation Item Bank (CPIB) using Item Response Theory (IRT). One overriding objective was to examine if the IRT item parameters would be consistent across different diagnostic groups, thereby allowing creation of a disorder-generic instrument. The intended outcomes were the final item bank and a short form ready for clinical and research applications. Methods Self-report data were collected from 701 individuals representing four diagnoses: multiple sclerosis, Parkinson’s disease, amyotrophic lateral sclerosis and head and neck cancer. Participants completed the CPIB and additional self-report questionnaires. CPIB data were analyzed using the IRT Graded Response Model (GRM). Results The initial set of 94 candidate CPIB items were reduced to an item bank of 46 items demonstrating unidimensionality, local independence, good item fit, and good measurement precision. Differential item function (DIF) analyses detected no meaningful differences across diagnostic groups. A 10-item, disorder-generic short form was generated. Conclusions The CPIB provides speech-language pathologists with a unidimensional, self-report outcomes measurement instrument dedicated to the construct of communicative participation. This instrument may be useful to clinicians and researchers wanting to implement measures of communicative participation in their work. PMID:23816661
FY94 CAG trip reports, CAG memos and other products: Volume 2. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-12-15
The Yucca Mountain Site Characterization Project (YMP) of the US DOE is tasked with designing, constructing, and operating an Exploratory Studies Facility (ESF) at Yucca Mountain, Nevada. The purpose of the YMP is to provide detailed characterization of the Yucca Mountain site for the potential mined geologic repository for permanent disposal of high-level radioactive waste. Detailed characterization of properties of the site are to be conducted through a wide variety of short-term and long-term in-situ tests. Testing methods require the installation of a large number of test instruments and sensors with a variety of functions. These instruments produce analog andmore » digital data that must be collected, processed, stored, and evaluated in an attempt to predict performance of the repository. The Integrated Data and Control System (IDCS) is envisioned as a distributed data acquisition that electronically acquires and stores data from these test instruments. IDCS designers are responsible for designing and overseeing the procurement of the system, IDCS Operation and Maintenance operates and maintains the installed system, and the IDCS Data Manager is responsible for distribution of IDCS data to participants. This report is a compilation of trip reports, interoffice memos, and other memos relevant to Computer Applications Group, Inc., work on this project.« less
Guerrero-Molina, Mónica; Moreno-Manso, Juan Manuel; Guerrero-Barona, Eloísa; Cruz-Márquez, Beatriz
2017-06-01
This work analyzes how the assumption of responsibility by aggressors convicted for gender-based violence is related to sexist attitudes, self-esteem and perceived functional social support. Similarly, the predictive capacity of these variables is studied with respect to the aggressors' minimization of the harm done and a lack of attributing responsibility to themselves. The participants in the research were males condemned to prison sentences for crimes related with gender-based violence in Spain. The instruments applied were the Attribution of Responsibility and Minimization of Harm Scale, the Ambivalent Sexism Inventory (ASI), the Rosenberg Self-Esteem Scale (RSE), the Functional Social Support Questionnaire (FSSQ), and the Social Desirability Scale (SDS). The study concludes that sexist attitudes are related with a greater lack of attribution of responsibility, as well as with a greater tendency to minimize the harm done by the aggression. In addition, the aggressors with low self-esteem use self-defense as a strategy to justify the violence. Similarly, the presence of an adequate social support network for the aggressor increases the attribution of responsibility on the part of those convicted for gender-based violence.
Site Response for Micro-Zonation from Small Earthquakes
NASA Astrophysics Data System (ADS)
Gospe, T. B.; Hutchings, L.; Liou, I. Y. W.; Jarpe, S.
2017-12-01
We have developed a method to obtain absolute geologic site response from small earthquakes using inexpensive instrumentation that enables us to perform micro-zonation inexpensively and in a short amount of time. We record small earthquakes (M<3) at several sites simultaneously and perform inversion to obtain actual absolute site response. The key to the inversion is that recordings at several stations from an earthquake have the same moment, source corner frequency and whole path Q effect on their spectra, but have individual Kappa and spectral amplification as a function of frequency. When these source and path effects are removed and corrections for different propagation distances are performed, we are left with actual site response. We develop site response functions from 0.5 to 25.0 Hz. Cities situated near active and dangerous faults experience small earthquakes on a regular basis. We typically record at least ten small earthquakes over time to stabilize the uncertainly. Of course, dynamic soil modeling is necessary to scale our linear site response to non-linear regime for large earthquakes. Our instrumentation is very inexpensive and virtually disposable, and can be placed throughout a city at a high density. Operation only requires turning on a switch, and data processing is automated to minimize human labor. We have installed a test network and implemented our full methodology in upper Napa Valley, California where there is variable geology and nearby rock outcrop sites, and a supply of small earthquakes from the nearby Geysers development area. We test several methbods of obtaining site response. We found that rock sites have a site response of their own and distort the site response estimate based upon spectral ratios with soil sites. Also, rock sites may not even be available near all sites throughout a city. Further, H/V site response estimates from earthquakes are marginally better, but vertical motion also has a site response of its own. H/V spectral ratios of noise don't provide accurate site response estimates either. Vs30 only provides one amplification number and doesn't account for the variable three-dimensional structure beneath sites. We conclude that absolute site response obtained directly from earthquakes is the best, and possibly, the only way to get accurate site response estimates.
SeaWiFS technical report series. Volume 15: The simulated SesWiFS data set, version 2
NASA Technical Reports Server (NTRS)
Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Gregg, Watson W.; Patt, Frederick S.; Woodward, Robert H.
1994-01-01
This document describes the second version of the simulated SeaWiFS data set. A realistic simulated data set is essential for mission readiness preparations and can potentially assist in all phases of ground support for a future mission. The second version improves on the first version primarily through additional realism and complexity. This version incorporates a representation of virtually every aspect of the flight mission. Thus, it provides a high-fidelity data set for testing several aspects of the ground system, including data acquisition, data processing, data transfers, calibration and validation, quality control, and mission operations. The data set is constructed for a seven-day period, 25-31 March 1994. Specific features of the data set include Global Area coverage (GAC), recorded Local Area Coverage (LAC), and realtime High Resolution Picture Transmission (HRPT) data for the seven-day period. A realistic orbit, which is propagated using a Brouwer-Lyddane model with drag, is used to simulate orbit positions. The simulated data corresponds to the command schedule based on the orbit for this seven-day period. It includes total (at-satellite) radiances not only for ocean, but for land, clouds, and ice. The simulation also utilizes a high-resolution land-sea mask. It includes the April 1993 SeaWiFS spectral responses and sensor saturation responses. The simulation is formatted according to July 1993 onboard data structures, which include corresponding telemetry (instrument and spacecraft) data. The methods are described and some examples of the output are given. The instrument response functions made available in April 1993 have been used to produce the Version 2 simulated data. These response functions will change as part of the sensor improvements initiated in July-August 1993.
Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds
NASA Technical Reports Server (NTRS)
Bhatt, Rajendra; Angal, Amit; Doelling, David R.; Xiong, Xiaoxiong; Wu, Aisheng; Haney, Conor O.; Scarino, Benjamin R.; Gopalan, Arun
2016-01-01
The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earths surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.
Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds
NASA Technical Reports Server (NTRS)
Bhatt, Rajendra; Angal, Amit; Doelling, David R.; Xiong, Xiaoxiong; Wu, Aisheng; Haney, Conor O.; Scarino, Benjamin R.; Gopalan, Arun
2016-01-01
The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earth's surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.
Response versus scan-angle corrections for MODIS reflective solar bands using deep convective clouds
NASA Astrophysics Data System (ADS)
Bhatt, Rajendra; Angal, Amit; Doelling, David R.; Xiong, Xiaoxiong; Wu, Aisheng; Haney, Conor O.; Scarino, Benjamin R.; Gopalan, Arun
2016-05-01
The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the degradation of the SD over time, provides the baseline for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the background, respectively. The MODIS instrument views the Earth's surface using a two-sided scan mirror, whose reflectance is a function of the angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different AOIs. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two AOIs. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from the pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for select short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent at the beginning of the earth-view scan.
Oude Voshaar, Martijn A H; Ten Klooster, Peter M; Vonkeman, Harald E; van de Laar, Mart A F J
2017-11-01
Traditional patient-reported physical function instruments often poorly differentiate patients with mild-to-moderate disability. We describe the development and psychometric evaluation of a generic item bank for measuring everyday activity limitations in outpatient populations. Seventy-two items generated from patient interviews and mapped to the International Classification of Functioning, Disability and Health (ICF) domestic life chapter were administered to 1128 adults representative of the Dutch population. The partial credit model was fitted to the item responses and evaluated with respect to its assumptions, model fit, and differential item functioning (DIF). Measurement performance of a computerized adaptive testing (CAT) algorithm was compared with the SF-36 physical functioning scale (PF-10). A final bank of 41 items was developed. All items demonstrated acceptable fit to the partial credit model and measurement invariance across age, sex, and educational level. Five- and ten-item CAT simulations were shown to have high measurement precision, which exceeded that of SF-36 physical functioning scale across the physical function continuum. Floor effects were absent for a 10-item empirical CAT simulation, and ceiling effects were low (13.5%) compared with SF-36 physical functioning (38.1%). CAT also discriminated better than SF-36 physical functioning between age groups, number of chronic conditions, and respondents with or without rheumatic conditions. The Rasch assessment of everyday activity limitations (REAL) item bank will hopefully prove a useful instrument for assessing everyday activity limitations. T-scores obtained using derived measures can be used to benchmark physical function outcomes against the general Dutch adult population.
The laval questionnaire: a new instrument to measure quality of life in morbid obesity.
Therrien, Fanny; Marceau, Picard; Turgeon, Nathalie; Biron, Simon; Richard, Denis; Lacasse, Yves
2011-08-15
Our recent review of the literature uncovered eleven obesity-specific quality of life questionnaires, all with incomplete demonstration of their measurement properties. Our objective was to validate a new self-administered questionnaire specific to morbid obesity to be used in clinical trials. The study was carried out at the bariatric surgery clinic of Laval Hospital, Quebec City, Canada. This study followed our description of health-related quality of life in morbid obesity from which we constructed the Laval Questionnaire. Its construct validity and responsiveness were tested by comparing the baseline and changes at 1-year follow-up in 6 domain scores (symptoms, activity/mobility, personal hygiene/clothing, emotions, social interactions, sexual life) with those of questionnaires measuring related constructs (SF-36, Impact of Weight on Quality of Life-Lite, Rosenberg Self-Esteem Scale and Beck Depression Inventory-II). 112 patients (67 who got bariatric surgery, 45 who remained on the waiting list during the study period) participated in this study. The analysis of the discriminative function of the questionnaire showed moderate-to-high correlations between the scores in each domain of our instrument and the corresponding questionnaires. The analysis of its evaluative function showed (1) significant differences in score changes between patients with bariatric surgery and those without, and (2) moderate-to-high correlations between the changes in scores in the new instrument and the changes in the corresponding questionnaires. Most of these correlations met the a priori predictions we had made regarding their direction and magnitude. The Laval Questionnaire is a valid measure of health-related quality of life in patients with morbid obesity and is responsive to treatment-induced changes.
NASA Astrophysics Data System (ADS)
Nehm, Ross H.; Ha, Minsu; Mayfield, Elijah
2012-02-01
This study explored the use of machine learning to automatically evaluate the accuracy of students' written explanations of evolutionary change. Performance of the Summarization Integrated Development Environment (SIDE) program was compared to human expert scoring using a corpus of 2,260 evolutionary explanations written by 565 undergraduate students in response to two different evolution instruments (the EGALT-F and EGALT-P) that contained prompts that differed in various surface features (such as species and traits). We tested human-SIDE scoring correspondence under a series of different training and testing conditions, using Kappa inter-rater agreement values of greater than 0.80 as a performance benchmark. In addition, we examined the effects of response length on scoring success; that is, whether SIDE scoring models functioned with comparable success on short and long responses. We found that SIDE performance was most effective when scoring models were built and tested at the individual item level and that performance degraded when suites of items or entire instruments were used to build and test scoring models. Overall, SIDE was found to be a powerful and cost-effective tool for assessing student knowledge and performance in a complex science domain.
NASA Astrophysics Data System (ADS)
Romani, Aldo; Grazia, Chiara; Anselmi, Chiara; Miliani, Costanza; Brunetti, Brunetto Giovanni
2011-06-01
In this paper a new compact and portable instrument for combined reflectance, time-resolved and steady-state fluorescence is presented. All the optical parts of the apparatus, carefully described in the text, were chosen after an extensive market survey in order to obtain the best performances coupled with the smallest dimensions. This instrument through the use of a dedicated multiple fiber optic probe, allows the complete photophysical behaviors of investigated materials to be collected from the same point of the analyzed surface. In this way, the resultant instrumental setup is a portable device, usable in situ for non destructive and non invasive diagnostic purposes in the field of cultural heritage. Preliminary results concerning organic dyes characterization, which is the main application of luminescence-based diagnostic techniques in artworks, are presented and compared with those previously obtained using separate devices. Concerning reflectance data, improvements in the deep detectable UV spectral range have been achieved switching from the integrating sphere of the old instrument to bifurcated optical fibers used as probe in the new one. Special attention was devoted to test the instrument capability in order to obtain the true emission spectrum, corrected for the selfabsorption effect, for which good results were found. This particular experimental procedure is strongly recommended, by a diagnostic point of view, to avoid distortions in the instrumental responses, namely the spectral shape and emission maximum wavelength of a fluorophore as function of the color saturation.
Telescience Testbed Program: A study of software for SIRTF instrument control
NASA Technical Reports Server (NTRS)
Young, Erick T.
1992-01-01
As a continued element in the Telescience Testbed Program (TTP), the University of Arizona Steward Observatory and the Electrical and Computer Engineering Department (ECE) jointly developed a testbed to evaluate the Operations and Science Instrument System (OASIS) software package for remote control of an instrument for the Space Infrared Telescope Facility (SIRTF). SIRTF is a cryogenically-cooled telescope with three focal plane instruments that will be the infrared element of NASA's Great Observatory series. The anticipated launch date for SIRTF is currently 2001. Because of the complexity of the SIRTF mission, it was not expected that the OASIS package would be suitable for instrument control in the flight situation, however, its possible use as a common interface during the early development and ground test phases of the project was considered. The OASIS package, developed at the University of Colorado for control of the Solar Mesosphere Explorer (SME) satellite, serves as an interface between the operator and the remote instrument which is connected via a network. OASIS provides a rudimentary windowing system as well as support for standard spacecraft communications protocols. The experiment performed all of the functions required of the MIPS simulation program. Remote control of the instrument was demonstrated but found to be inappropriate for SIRTF at this time for the following reasons: (1) programming interface is too difficult; (2) significant computer resources were required to run OASIS; (3) the communications interface is too complicated; (4) response time was slow; and (5) quicklook of image data was not possible.
NASA Astrophysics Data System (ADS)
Vincent, M.; Xolin, P.; Gevrey, A.-M.; Thiebaud, F.; Engels-Deutsch, M.; Ben Zineb, T.
2017-04-01
This paper presents an experimental and numerical study showing that single crystal shape memory alloy (SMA) Cu-based endodontic instruments can lead to equivalent mechanical performances compared to NiTi-based instruments besides their interesting biological properties. Following a previous finite element analysis (FEA) of single crystal CuAlBe endodontic instruments (Vincent et al 2015 J. Mater. Eng. Perform. 24 4128-39), prototypes with the determined geometrical parameters were machined and experimentally characterized in continuous rotation during a penetration/removal (P/R) protocol in artificial canals. The obtained mechanical responses were compared to responses of NiTi endodontic files in the same conditions. In addition, FEA was conducted and compared with the experimental results to validate the adopted modeling and to evaluate the local quantities inside the instrument as the stress state and the distribution of volume fraction of martensite. The obtained results highlight that single crystal CuAlBe SMA prototypes show equivalent mechanical responses to its NiTi homologous prototypes in the same P/R experimental conditions.
Sex Differences in Tibial Bone Strength
NASA Technical Reports Server (NTRS)
Arnaud, Sara B.; Hutchinson, T. M.; Torikoshi, S.; Hutchinson, K. J.; Hargens, Alan R.; Steele, C. R.
1995-01-01
We have used an instrument (MRTA or Mechanical Response Tissue Analyzer) that measures bending stiffness (EI) non-Invasively to evaluate the strength of the tibia, a long bone in the weightbearing skeleton highly vulnerable to mineral loss during space flight. In healthy men, we found asymmetry in EI consistent with the bone's support function (L greater than R). In this study, we analyzed EI in women and compared the results to those in men.
Infrasound Sensor Calibration and Response
2012-09-01
infrasound calibration chamber. Under separate funding a number of upgrades were made to the chamber. These include a Geotech Smart24 digitizer and...of upgrades were made to the chamber. These include a Geotech Smart24 digitizer and workstation, an LVDT sensor for piston phone phase measurement, a...20 samples per second on a GeoTech Instruments DL 24 digitizer. Fifty cycles of data were fit with the Matlab function NLINFIT that gave the peak
Sousa, Liliana B; Simões, Mário R; Firmino, Horácio; Peisah, Carmelle
2014-02-01
Mental health professionals are frequently involved in mental capacity determinations. However, there is a lack of specific measures and well-defined procedures for these evaluations. The main purpose of this paper is to provide a review of financial and testamentary capacity evaluation procedures, including not only the traditional neuropsychological and functional assessment but also the more recently developed forensic assessment instruments (FAIs), which have been developed to provide a specialized answer to legal systems regarding civil competencies. Here the main guidelines, papers, and other references are reviewed in order to achieve a complete and comprehensive selection of instruments used in the assessment of financial and testamentary capacity. Although some specific measures for financial abilities have been developed recently, the same is not true for testamentary capacity. Here are presented several instruments or methodologies for assessing financial and testamentary capacity, including neuropsychological assessment, functional assessment scales, performance based functional assessment instruments, and specific FAIs. FAIs are the only specific instruments intended to provide a specific and direct answer to the assessment of financial capacity based on legal systems. Considering the need to move from a diagnostic to a functional approach in financial and testamentary capacity evaluations, it is essential to consider both general functional examination as well as cognitive functioning.
Abma, Femke I; van der Klink, Jac J L; Bültmann, Ute
2013-03-01
The promotion of a sustainable, healthy and productive working life attracts more and more attention. Recently the Work Role Functioning Questionnaire (WRFQ) has been cross-culturally translated and adapted to Dutch. This questionnaire aims to measure the health-related work functioning of workers with health problems. The aim of this study is to evaluate the reliability, validity (including five new items) and responsiveness of the WRFQ 2.0 in the working population. A longitudinal study was conducted among workers. The reliability (internal consistency, test-retest reliability, measurement error), validity (structural validity-factor analysis, construct validity by means of hypotheses testing) and responsiveness of the WRFQ 2.0 were evaluated. A total of N = 553 workers completed the survey. The final WRFQ 2.0 has four subscales and showed very good internal consistency, moderate test-retest reliability, good construct validity and moderate responsiveness in the working population. The WRFQ was able to distinguish between groups with different levels of mental health, physical health, fatigue and need for recovery. A moderate correlation was found between WRFQ and related constructs respectively work ability and work productivity. A weak relationship was found with general self-rated health, work engagement and work involvement. The WRFQ 2.0 is a reliable and valid instrument to measure health-related work functioning in the working population. Further validation in larger samples is recommended, especially for test-retest reliability, responsiveness and the questionnaire's ability to predict the future course of health-related work functioning.
An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery.
Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Shamdani, Amir Hossein; Smith, Julian; Zhong, Yongmin
2014-03-01
Robotic-assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic instruments but also have other important advantages, including restoring the surgeon's hand-eye coordination and improving the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Various solutions for restoring this feature have been proposed. An actuated modular force feedback-enabled laparoscopic instrument was proposed that is able to measure tip-tissue lateral interaction forces as well as normal grasping forces. The instrument has also the capability to adjust the grasping direction inside the patient body. In order to measure the interaction forces, strain gauges were employed. A series of finite element analyses were performed to gain an understanding of the actual magnitude of surface strains where gauges are applied. The strain gauge bridge configurations were calibrated. A series of experiments was conducted and the results were analysed. The modularity feature of the proposed instrument makes it interchangeable between various tip types of different functionalities (e.g. cutter, grasper, dissector). Calibration results of the strain gauges incorporated into the tube and at the base of the instrument presented the monotonic responses for these strain gauge configurations. Experimental results from tissue probing and tissue characterization experiments verified the capability of the proposed instrument in measuring lateral probing forces and characterizing artificial tissue samples of varying stiffness. The proposed instrument can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations. Copyright © 2013 John Wiley & Sons, Ltd.
Aqil, Muhammad; Jeong, Myung Yung
2018-04-24
The robust characterization of real-time brain activity carries potential for many applications. However, the contamination of measured signals by various instrumental, environmental, and physiological sources of noise introduces a substantial amount of signal variance and, consequently, challenges real-time estimation of contributions from underlying neuronal sources. Functional near infra-red spectroscopy (fNIRS) is an emerging imaging modality whose real-time potential is yet to be fully explored. The objectives of the current study are to (i) validate a time-dependent linear model of hemodynamic responses in fNIRS, and (ii) test the robustness of this approach against measurement noise (instrumental and physiological) and mis-specification of the hemodynamic response basis functions (amplitude, latency, and duration). We propose a linear hemodynamic model with time-varying parameters, which are estimated (adapted and tracked) using a dynamic recursive least square algorithm. Owing to the linear nature of the activation model, the problem of achieving robust convergence to an accurate estimation of the model parameters is recast as a problem of parameter error stability around the origin. We show that robust convergence of the proposed method is guaranteed in the presence of an acceptable degree of model misspecification and we derive an upper bound on noise under which reliable parameters can still be inferred. We also derived a lower bound on signal-to-noise-ratio over which the reliable parameters can still be inferred from a channel/voxel. Whilst here applied to fNIRS, the proposed methodology is applicable to other hemodynamic-based imaging technologies such as functional magnetic resonance imaging. Copyright © 2018 Elsevier Inc. All rights reserved.
Health related quality of life in disorders of defecation: the Defecation Disorder List
Voskuijl, W; van der Zaag-Loon..., H J; Ketel, I; Grootenhuis, M; Derkx, B; Benninga, M
2004-01-01
Background: Constipation and encopresis frequently cause problems with respect to emotional wellbeing, and social and family life. Instruments to measure Health Related Quality of Life (HRQoL) in these disorders are not available. Methods: A disease specific HRQoL instrument, the "Defecation Disorder List" (DDL) for children with constipation or functional non-retentive faecal soiling (FNRFS) was developed using accepted guidelines. For each phase of the process, different samples of patients were used. The final phase of development included 27 children. Reliability was assessed in two ways: internal consistency of domains with Cronbach's alpha, and test-retest reliability with intra-class correlation coefficients (ICC). To assess validity, comparable items and domains were correlated with Tacqol, a generic HRQoL instrument for children (TNO-AZL). Results: In the final phase of the development, 27 children completed the instrument. It consisted of 37 items in four domains. The response rate was 96%. Reliability was good for all domains, with Cronbach's alpha values ranging from 0.61 to 0.76. Measures of test-retest stability were good for all four domains with ICCs ranging from 0.82 to 0.92. Validity based on comparison with the Tacqol instrument was moderate. Conclusion: The DDL is promising as a measure of HRQoL in childhood defecation disorders. PMID:15557046
TREMOR: A wireless MEMS accelerograph for dense arrays
Evans, J.R.; Hamstra, R.H.; Kundig, C.; Camina, P.; Rogers, J.A.
2005-01-01
The ability of a strong-motion network to resolve wavefields can be described on three axes: frequency, amplitude, and space. While the need for spatial resolution is apparent, for practical reasons that axis is often neglected. TREMOR is a MEMS-based accelerograph using wireless Internet to minimize lifecycle cost. TREMOR instruments can economically augment traditional ones, residing between them to improve spatial resolution. The TREMOR instrument described here has dynamic range of 96 dB between ??2 g, or 102 dB between ??4 g. It is linear to ???1% of full scale (FS), with a response function effectively shaped electronically. We developed an economical, very low noise, accurate (???1%FS) temperature compensation method. Displacement is easily recovered to 10-cm accuracy at full bandwidth, and better with care. We deployed prototype instruments in Oakland, California, beginning in 1998, with 13 now at mean spacing of ???3 km - one of the most densely instrumented urban centers in the United States. This array is among the quickest in returning (PGA, PGV, Sa) vectors to ShakeMap, ???75 to 100 s. Some 13 events have been recorded. A ShakeMap and an example of spatial variability are shown. Extensive tests of the prototypes for a commercial instrument are described here and in a companion paper. ?? 2005, Earthquake Engineering Research Institute.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, H.; Dean, J.; Privas, E.
2015-03-15
Nuclear plant operators (power generation, decommissioning and reprocessing operations) are required to monitor releases of tritium species for regulatory compliance and radiation protection purposes. Tritium monitoring is performed using tritium-in-air gas monitoring instrumentation based either on flow-through ion chambers or proportional counting systems. Tritium-in-air monitors are typically calibrated in dry conditions but in service may operate at elevated levels of relative humidity. The NPL (National Physical Laboratory) radioactive gas-in-air calibration system has been used to study the effect of humidity on the response to tritium of two tritium-in-air ion chamber based monitors and one proportional counting system which uses amore » P10/air gas mixture. The response of these instruments to HTO vapour has also been evaluated. In each case, instrument responses were obtained for HT in dry conditions (relative humidity (RH) about 2%), HT in 45% RH, and finally HTO at 45% RH. Instrumentation response to HT in humid conditions has been found to slightly exceed that in dry conditions. (authors)« less
The function and response of an improved stratospheric condensation nucleus counter
NASA Technical Reports Server (NTRS)
Wilson, J. C.; Hyun, J. H.; Blackshear, E. D.
1983-01-01
An improved condensation nucleus counter (CNC) for use in the stratosphere is described. The University of Minnesota CNC (UMCNC) has a sequential saturator and condenser and uses n-butyl alcohol as the working fluid. The use of a coaxial saturator flow, with aerosol in the center and filtered, alcohol-laden air around it, speeds the response of this instrument and improves its stability as pressure changes. The counting efficiency has been studied as a function of particle size and pressure. The UMCNC provides an accurate measure of submicron aerosol concentration as long as the number distribution is not dominated by sub-0.02 micron diameter aerosol. The response of the UMCNC is compared with that of other stratospheric condensation nucleus counters, and the results of a (near) comparison with a balloon-borne condensation nucleus counter are presented. The UMCNC has operated 14 times on a NASA U-2 aircraft at altitudes from 8 to 21.5 km.
West, Courtney; Landry, Karen; Graham, Anna; Graham, Lori; Cianciolo, Anna T; Kalet, Adina; Rosen, Michael; Sherman, Deborah Witt
2015-01-01
SGEA 2015 CONFERENCE ABSTRACT (EDITED). Evaluating Interprofessional Teamwork During a Large-Scale Simulation. Courtney West, Karen Landry, Anna Graham, and Lori Graham. CONSTRUCT: This study investigated the multidimensional measurement of interprofessional (IPE) teamwork as part of large-scale simulation training. Healthcare team function has a direct impact on patient safety and quality of care. However, IPE team training has not been the norm. Recognizing the importance of developing team-based collaborative care, our College of Nursing implemented an IPE simulation activity called Disaster Day and invited other professions to participate. The exercise consists of two sessions: one in the morning and another in the afternoon. The disaster scenario is announced just prior to each session, which consists of team building, a 90-minute simulation, and debriefing. Approximately 300 Nursing, Medicine, Pharmacy, Emergency Medical Technicians, and Radiology students and over 500 standardized and volunteer patients participated in the Disaster Day event. To improve student learning outcomes, we created 3 competency-based instruments to evaluate collaborative practice in multidimensional fashion during this exercise. A 20-item IPE Team Observation Instrument designed to assess interprofessional team's attainment of Interprofessional Education Collaborative (IPEC) competencies was completed by 20 faculty and staff observing the Disaster Day simulation. One hundred sixty-six standardized patients completed a 10-item Standardized Patient IPE Team Evaluation Instrument developed from the IPEC competencies and adapted items from the 2014 Henry et al. PIVOT Questionnaire. This instrument assessed the standardized or volunteer patient's perception of the team's collaborative performance. A 29-item IPE Team's Perception of Collaborative Care Questionnaire, also created from the IPEC competencies and divided into 5 categories of Values/Ethics, Roles and Responsibilities, Communication, Teamwork, and Self-Evaluation, was completed by 188 students including 99 from Nursing, 43 from Medicine, 6 from Pharmacy, and 40 participants who belonged to more than one component, were students at another institution, or did not indicate their institution. The team instrument was designed to assess each team member's perception of how well the team and him- or herself met the competencies. Five of the items on the team perceptions questionnaire mirrored items on the standardized patient evaluation: demonstrated leadership practices that led to effective teamwork, discussed care and decisions about that care with patient, described roles and responsibilities clearly, worked well together to coordinate care, and good/effective communication. Internal consistency reliability of the IPE Team Observation Instrument was 0.80. In 18 of the 20 items, more than 50% of observers indicated the item was demonstrated. Of those, 6 of the items were observed by 50% to 75% of the observers, and the remaining 12 were observed by more than 80% of the observers. Internal consistency reliability of the IPE Team's Perception of Collaborative Care Instrument was 0.95. The mean response score-1 (strongly disagree) to 4 (strongly agree)-was calculated for each section of the instrument. The overall mean score was 3.57 (SD = .11). Internal consistency reliability of the Standardized Patient IPE Team Evaluation Instrument was 0.87. The overall mean score was 3.28 (SD = .17). The ratings for the 5 items shared by the standardized patient and team perception instruments were compared using independent sample t tests. Statistically significant differences (p < .05) were present in each case, with the students rating themselves higher on average than the standardized patients did (mean differences between 0.2 and 0.6 on a scale of 1-4). Multidimensional, competency-based instruments appear to provide a robust view of IPE teamwork; however, challenges remain. Due to the large scale of the simulation exercise, observation-based assessment did not function as well as self- and standardized patient-based assessment. To promote greater variation in observer assessments during future Disaster Day simulations, we plan to adjust the rating scale from "not observed," "observed," and "not applicable" to a 4-point scale and reexamine interrater reliability.
Rosenfeld, C R; Gant, N F
1981-01-01
Vascular refractoriness to the systemic pressor effects of angiotension II (AII) develops normally during human pregnancy. To ascertain if the ewe might provide a suitable animal model to study the mechanisms responsible for this response (unique to pregnancy) we studied this phenomenon in unanesthetized, chronically instrumented nonpregnant and pregnant sheep, 68-143 d gestation. In these studies dose-response curves were established for changes in both mean arterial pressure and uterine blood flow. The pressor response to continuous infusions of AII increases as a function of the dose of AII in both nonpregnant and pregnant animals (P less than 0.001), R = 0.943 and 0.879, respectively. However, the pregnant animals were refractory to the pressor effects of AII, requiring 0.016 microgram of AII/min per kg to elicit a 20 mm HG rise in mean arterial pressure, in contrast to 0.009 for nonpregnant animals. The slope and intercept for the regression lines are different at P less than 0.001. In pregnant animals the dose-response curve for uterine blood flow was also determined. Increases in uterine blood flow were observed at doses of AII less than 0.016 microgram/min per kg, while larger doses resulted in a progressively greater reduction in blood flow. It appears likely that the ewe may serve as an animal model suitable for the further study of the unique pregnancy-modified systemic and uteroplacental vascular responses elicited by AII. PMID:7462427
Validation of a quality-of-life instrument for patients with nonmelanoma skin cancer.
Rhee, John S; Matthews, B Alex; Neuburg, Marcy; Logan, Brent R; Burzynski, Mary; Nattinger, Ann B
2006-01-01
To validate a disease-specific quality-of-life instrument--the Skin Cancer Index--intended to measure quality-of-life issues relevant to patients with nonmelanoma skin cancer. Internal reliability, convergent and divergent validity with existing scales, and factor analyses were performed in a cross-sectional study of 211 patients presenting with cervicofacial nonmelanoma skin cancer to a dermatologic surgery clinic. Factor analyses of the Skin Cancer Index confirmed a multidimensional scale with 3 distinct subscales-emotional, social, and appearance. Excellent internal validity of the 3 subscales was demonstrated. Substantial evidence was observed for convergent validity with the Dermatology Life Quality Index, Rosenberg Self-Esteem Scale, Lerman's Cancer Worry Scale, and Medical Outcomes Survey Short-Form 12 domains for vitality, emotion, social function, and mental health. These findings validate a new disease-specific quality-of-life instrument for patients with cervicofacial nonmelanoma skin cancer. Studies on the responsiveness of the Skin Cancer Index to clinical intervention are currently under way.
QuickPol: Fast calculation of effective beam matrices for CMB polarization
NASA Astrophysics Data System (ADS)
Hivon, Eric; Mottet, Sylvain; Ponthieu, Nicolas
2017-02-01
Current and planned observations of the cosmic microwave background (CMB) polarization anisotropies, with their ever increasing number of detectors, have reached a potential accuracy that requires a very demanding control of systematic effects. While some of these systematics can be reduced in the design of the instruments, others will have to be modeled and hopefully accounted for or corrected a posteriori. We propose QuickPol, a quick and accurate calculation of the full effective beam transfer function and of temperature to polarization leakage at the power spectra level, as induced by beam imperfections and mismatches between detector optical and electronic responses. All the observation details such as exact scanning strategy, imperfect polarization measurements, and flagged samples are accounted for. Our results are validated on Planck high frequency instrument (HFI) simulations. We show how the pipeline can be used to propagate instrumental uncertainties up to the final science products, and could be applied to experiments with rotating half-wave plates.
Instrument technology for remote-surface exploration, prospecting and assaying, part 2
NASA Technical Reports Server (NTRS)
Brereton, R. G.
1977-01-01
The capability to specify new instrument/mechanism technology needs, for effective remote surface exploration, prospecting and assaying (EPA), requires first, an understanding of the functions or major elements of such a task, and second an understanding of the scientific instruments and support mechanisms that may be involved. An analog or task model was developed from which the various functions, operational procedures, scientific instruments, and support mechanisms for an automated mission could be derived. The task model led to the definition of nine major functions or categories of discrete operational elements that may have to be accomplished on a mission of this type. Each major function may stand alone as an element of an EPA mission, but more probably a major function will require the support of other functions, so they are inter-related.
2012-01-01
Background Item response theory (IRT) is extensively used to develop adaptive instruments of health-related quality of life (HRQoL). However, each IRT model has its own function to estimate item and category parameters, and hence different results may be found using the same response categories with different IRT models. The present study used the Rasch rating scale model (RSM) to examine and reassess the psychometric properties of the Persian version of the PedsQLTM 4.0 Generic Core Scales. Methods The PedsQLTM 4.0 Generic Core Scales was completed by 938 Iranian school children and their parents. Convergent, discriminant and construct validity of the instrument were assessed by classical test theory (CTT). The RSM was applied to investigate person and item reliability, item statistics and ordering of response categories. Results The CTT method showed that the scaling success rate for convergent and discriminant validity were 100% in all domains with the exception of physical health in the child self-report. Moreover, confirmatory factor analysis supported a four-factor model similar to its original version. The RSM showed that 22 out of 23 items had acceptable infit and outfit statistics (<1.4, >0.6), person reliabilities were low, item reliabilities were high, and item difficulty ranged from -1.01 to 0.71 and -0.68 to 0.43 for child self-report and parent proxy-report, respectively. Also the RSM showed that successive response categories for all items were not located in the expected order. Conclusions This study revealed that, in all domains, the five response categories did not perform adequately. It is not known whether this problem is a function of the meaning of the response choices in the Persian language or an artifact of a mostly healthy population that did not use the full range of the response categories. The response categories should be evaluated in further validation studies, especially in large samples of chronically ill patients. PMID:22414135
CRiSP: An Instrument for Assessing Student Perceptions of Classroom Response Systems
ERIC Educational Resources Information Center
Richardson, Alice M.; Dunn, Peter K.; McDonald, Christine; Oprescu, Florin
2015-01-01
This paper describes the development and validation of an instrument for evaluating classroom response systems (CRS). While a number of studies evaluating CRS have been published to date, no standardised instrument exists as a means of evaluating the impact of using the CRS. This means that comparing the different systems, or evaluating the…
Cortical Signal Analysis and Advances in Functional Near-Infrared Spectroscopy Signal: A Review.
Kamran, Muhammad A; Mannan, Malik M Naeem; Jeong, Myung Yung
2016-01-01
Functional near-infrared spectroscopy (fNIRS) is a non-invasive neuroimaging modality that measures the concentration changes of oxy-hemoglobin (HbO) and de-oxy hemoglobin (HbR) at the same time. It is an emerging cortical imaging modality with a good temporal resolution that is acceptable for brain-computer interface applications. Researchers have developed several methods in last two decades to extract the neuronal activation related waveform from the observed fNIRS time series. But still there is no standard method for analysis of fNIRS data. This article presents a brief review of existing methodologies to model and analyze the activation signal. The purpose of this review article is to give a general overview of variety of existing methodologies to extract useful information from measured fNIRS data including pre-processing steps, effects of differential path length factor (DPF), variations and attributes of hemodynamic response function (HRF), extraction of evoked response, removal of physiological noises, instrumentation, and environmental noises and resting/activation state functional connectivity. Finally, the challenges in the analysis of fNIRS signal are summarized.
Cortical Signal Analysis and Advances in Functional Near-Infrared Spectroscopy Signal: A Review
Kamran, Muhammad A.; Mannan, Malik M. Naeem; Jeong, Myung Yung
2016-01-01
Functional near-infrared spectroscopy (fNIRS) is a non-invasive neuroimaging modality that measures the concentration changes of oxy-hemoglobin (HbO) and de-oxy hemoglobin (HbR) at the same time. It is an emerging cortical imaging modality with a good temporal resolution that is acceptable for brain-computer interface applications. Researchers have developed several methods in last two decades to extract the neuronal activation related waveform from the observed fNIRS time series. But still there is no standard method for analysis of fNIRS data. This article presents a brief review of existing methodologies to model and analyze the activation signal. The purpose of this review article is to give a general overview of variety of existing methodologies to extract useful information from measured fNIRS data including pre-processing steps, effects of differential path length factor (DPF), variations and attributes of hemodynamic response function (HRF), extraction of evoked response, removal of physiological noises, instrumentation, and environmental noises and resting/activation state functional connectivity. Finally, the challenges in the analysis of fNIRS signal are summarized. PMID:27375458
Garofalo, Sara; Robbins, Trevor W
2017-01-01
The present study investigates human aversive Pavlovian-to-Instrumental Transfer (PIT) and possible influences of outcome devaluation and instrumental overtraining on this effect. PIT measures the extent to which a Pavlovian conditioned stimulus (CS) can increase instrumental responses independently paired with the same (outcome-specific transfer) or a different (general transfer) reinforcer. Two measures of PIT were obtained: the percentage of instrumental responses and the vigor of such responses. Thirty-eight volunteers performed a standard PIT task sequence. Results showed a double dissociation between outcome-specific and general transfer: the first selectively expressed in the amount of responses, the second in the vigor measure solely. Furthermore, outcome-specific transfer was enhanced by overtraining, but not affected by devaluation. General transfer, on the other hand, was affected by neither overtraining, nor devaluation. A positive correlation between general transfer and sensitivity to punishments was found. Findings are discussed in terms of hypothetically different underlying neurobehavioral mechanisms and their relations to habits and goal-directed behavior.
Trzcińska, Agata; Sekścińska, Katarzyna
2016-01-01
The psychological model of thinking about money assumes that implicit reminders of money lead to self-sufficient motivation. Previous research has demonstrated that children react to money in similar ways to adults. The priming of young children with money related concepts or images has negatively affected their social behavior and social preferences, leading them to make more individualist and less pro-social choices and be less willing to help others. The aim of this research was to investigate the positive influence of money activation on children’s behavior. The participants were 6–8 year old children who do not yet fully understand the instrumental function of money due to their young age. Two experimental studies were performed, the first of which analyzed the effect of perseverance and performance on a challenging task and the second investigated preferences with respect to delaying gratification. Sixty-one children aged 6 took part in the first study and forty-six scout camp participants 6–8 years of age were involved in the second experiment. The results support the hypotheses concerning the effects of money activation stating that (1) money activation influences children’s perseverance and effectiveness in difficult individual tasks, and that (2) it increases children’s preferences for delayed gratification. These results suggest that money has a symbolic power which may exert both positive and negative effects on children’s behavior. Since children between the ages of 6 and 8 do not understand the instrumental function of money fully, certain symbolic meanings of money may have been responsible for the money priming effects. The findings suggest that the symbolic function of money is more primal than its instrumental function and that it probably develops at an earlier stage in life. PMID:27199842
Trzcińska, Agata; Sekścińska, Katarzyna
2016-01-01
The psychological model of thinking about money assumes that implicit reminders of money lead to self-sufficient motivation. Previous research has demonstrated that children react to money in similar ways to adults. The priming of young children with money related concepts or images has negatively affected their social behavior and social preferences, leading them to make more individualist and less pro-social choices and be less willing to help others. The aim of this research was to investigate the positive influence of money activation on children's behavior. The participants were 6-8 year old children who do not yet fully understand the instrumental function of money due to their young age. Two experimental studies were performed, the first of which analyzed the effect of perseverance and performance on a challenging task and the second investigated preferences with respect to delaying gratification. Sixty-one children aged 6 took part in the first study and forty-six scout camp participants 6-8 years of age were involved in the second experiment. The results support the hypotheses concerning the effects of money activation stating that (1) money activation influences children's perseverance and effectiveness in difficult individual tasks, and that (2) it increases children's preferences for delayed gratification. These results suggest that money has a symbolic power which may exert both positive and negative effects on children's behavior. Since children between the ages of 6 and 8 do not understand the instrumental function of money fully, certain symbolic meanings of money may have been responsible for the money priming effects. The findings suggest that the symbolic function of money is more primal than its instrumental function and that it probably develops at an earlier stage in life.
Psychometric properties of the WHODASII in rehabilitation patients.
Pösl, Miriam; Cieza, Alarcos; Stucki, Gerold
2007-11-01
To evaluate function and disability, the WHO has developed the WHO Disability Assessment Schedule II (WHODASII), an instrument arising from the same conceptual basis as the International Classification of Functioning, Disability, and Health (ICF). The general objective of this study was to investigate whether the WHODASII--German version-is a valid instrument to measure functioning and disability across various conditions. Specific aims were (1) to assess its psychometric properties (reliability, validity, and sensitivity to change) based on the traditional test theory and (2) to compare its sensitivity to change after a rehabilitative intervention to the Short Form 36 (SF-36). This was a multi-center study with convenience samples of patients with different chronic conditions undergoing rehabilitation. Patients completed the WHODASII and the SF-36 before and after a rehabilitation treatment. Health professionals rated in cooperation with the patients the pain of the patients based on the ICF category "sensation of pain." 904 patients were included in the study. The Cronbach's range from 0.70 to 0.97 for the different subscales of WHODASII. With exception of the subscale Activities, the exploratory-factor structure of the WHODASII corresponds highly with the original structure. The effect size (ES) of the WHODASII total score ranged from 0.16 to 0.69 depending on the subgroup. The ES of the SF-36 summary scores ranged from 0.03 to 1.40. The WHODAS II (German version) is a useful instrument for measuring functioning and disability in patients with musculoskeletal diseases, internal diseases, stroke, breast cancer, and depressive disorder. The results of this study support the reliability, validity, dimensionality, and responsiveness of the German version of the WHODASII. However, the reproducibility in test-retest samples of stable patients, as well as the question to what extent a summary score can be constructed, requires further investigation.
Extinction and the associative structure of heterogeneous instrumental chains.
Thrailkill, Eric A; Bouton, Mark E
2016-09-01
Drug abuse, overeating, and smoking are all examples of instrumental behaviors that often involve chains or sequences of behavior. A behavior chain is minimally composed of a procurement response that is required in order for a subsequent consumption response to be reinforced. Despite the translational importance of behavior chains, few studies have attempted to understand what binds them together and takes them apart. This article surveys the development of the heterogeneous instrumental chain method and introduces recent findings that have used extinction to analyze the associative content of (what is learned in) the chain. Chained responses that are occasion-set by their own discriminative stimuli may be directly associated; extinction of the procurement response weakens its associated consumption response, and extinction of the consumption response weakens its associated procurement response. Extinction itself involves learning to inhibit the response. Extinguished chained responses are subject to renewal when they are tested either back in the acquisition context or in a new context. In addition, a consumption response that is extinguished outside its chain is renewed when returned to the context of the preceding response in the chain. Research on heterogeneous behavior chains can provide important insights into an important but often overlooked aspect of instrumental learning. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gillet, Gordon; Alvarez, José Luis; Beltrán, Juan; Bourget, Pierre; Castillo, Roberto; Diaz, Álvaro; Haddad, Nicolás; Leiva, Alfredo; Mardones, Pedro; O'Neal, Jared; Ribes, Mauricio; Riquelme, Miguel; Robert, Pascal; Rojas, Chester; Valenzuela, Javier
2010-07-01
This presentation provides interesting miscellaneous information regarding the instrumentation activities at Paranal Observatory. It introduces the suite of 23 instruments and auxiliary systems that are under the responsibility of the Paranal Instrumentation group, information on the type of instruments, their usage and downtime statistics. The data is based on comprehensive data recorded in the Paranal Night Log System and the Paranal Problem Reporting System whose principles are explained as well. The work organization of the 15 team members around the high number of instruments is laid out, which includes: - Maintaining older instruments with obsolete components - Receiving new instruments and supporting their integration and commissioning - Contributing to future instruments in their developing phase. The assignments of the Instrumentation staff to the actual instruments as well as auxiliary equipment (Laser Guide Star Facility, Mask Manufacturing Unit, Cloud Observation Tool) are explained with respect to responsibility and scheduling issues. The essential activities regarding hardware & software are presented, as well as the technical and organizational developments within the group towards its present and future challenges.
NASA Technical Reports Server (NTRS)
Kester, DO; Bontekoe, Tj. Romke
1994-01-01
In order to make the best high resolution images of IRAS data it is necessary to incorporate any knowledge about the instrument into a model: the IRAS model. This is necessary since every remaining systematic effect will be amplified by any high resolution technique into spurious artifacts in the images. The search for random noise is in fact the never-ending quest for better quality results, and can only be obtained by better models. The Dutch high-resolution effort has resulted in HIRAS which drives the MEMSYS5 algorithm. It is specifically designed for IRAS image construction. A detailed description of HIRAS with many results is in preparation. In this paper we emphasize many of the instrumental effects incorporated in the IRAS model, including our improved 100 micron IRAS response functions.
NASA Astrophysics Data System (ADS)
Gómez-Sáenz-de-Tejada, Jaime; Toledo-Moreo, Rafael; Colodro-Conde, Carlos; Pérez-Lizán, David; Fernández-Conde, Jesús; Sánchez-Prieto, Sebastián.
2016-07-01
The Near Infrared Spectrograph and Photometer (NISP) is one of the instruments on board the ESA EUCLID mission. The Boot Software (BSW) is in charge of initialization and communications after a reset occurs at hard- ware level. The Universidad Politecnica de Cartagena and Instituto de Astrofisica de Canarias are responsible of the Instrument Control Unit of the NISP (NI-ICU) in the Euclid Consortium. The NI-ICU BSW is developed by Universidad de Alcaĺa, and its main functions are: communication with the S/C for memory management, self-tests and start of a patchable Application Software (ASW). This paper presents the NI-ICU BSW status of definition and design at the end of the Technical Specification phase.
Structural power flow measurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Falter, K.J.; Keltie, R.F.
Previous investigations of structural power flow through beam-like structures resulted in some unexplained anomalies in the calculated data. In order to develop structural power flow measurement as a viable technique for machine tool design, the causes of these anomalies needed to be found. Once found, techniques for eliminating the errors could be developed. Error sources were found in the experimental apparatus itself as well as in the instrumentation. Although flexural waves are the carriers of power in the experimental apparatus, at some frequencies longitudinal waves were excited which were picked up by the accelerometers and altered power measurements. Errors weremore » found in the phase and gain response of the sensors and amplifiers used for measurement. A transfer function correction technique was employed to compensate for these instrumentation errors.« less
STEREO/SEPT particle observations during the CIR event on 2011 August 9
NASA Astrophysics Data System (ADS)
Dresing, N.; Heber, B.; Klassen, A.; Kühl, P.; Boettcher, S. I.; Gomez-Herrero, R.; Wraase, S.
2017-12-01
Among others, shocks are known to be accelerators of energetic charged particles. However, many questions regarding the acceleration efficiency and the required conditions are not fully understood. In particular, the acceleration of electrons by shocks is often questioned. Recurrent energetic particle events are caused by the passage of Corotating Interaction Regions (CIRs) that have been extensively analysed by different instrumentation close to Earth. Measurements of the Solar Electron and Proton Telescope aboard the Solar TErrestrial RElations Observatory are utilized in the solar heliospheric community to investigate electron events. Due to its measurement principle, the magnet foil technique, ions can contribute to the electron channel. This effect is well known. During recurrent energetic particle events the averaged helium to proton ration is enhanced to more than 10%. The energy per nucleon spectra are nearly the same for protons and helium. Although the electron intensity profile is influenced by an ion contamination during the shock crossings it is not obvious that electrons are not enhanced during such periods. Computation using a GEANT4 simulation of the SEPT instrument resulted in response function for ions and electrons. These response functions have been utilzed to analyze the recurrent energetic particle event that was was measured by STEREO B on August 9, 2011. Assuming a constant helium to proton ratio and energy spectra described by a Band function we found that electron and ion measurement can be explained by the contribution of helium and protons with an helium to proton ratio of about 16%. Thus no electron enhancements are needed to explain the SEPT measurements.
Convolution kernels for multi-wavelength imaging
NASA Astrophysics Data System (ADS)
Boucaud, A.; Bocchio, M.; Abergel, A.; Orieux, F.; Dole, H.; Hadj-Youcef, M. A.
2016-12-01
Astrophysical images issued from different instruments and/or spectral bands often require to be processed together, either for fitting or comparison purposes. However each image is affected by an instrumental response, also known as point-spread function (PSF), that depends on the characteristics of the instrument as well as the wavelength and the observing strategy. Given the knowledge of the PSF in each band, a straightforward way of processing images is to homogenise them all to a target PSF using convolution kernels, so that they appear as if they had been acquired by the same instrument. We propose an algorithm that generates such PSF-matching kernels, based on Wiener filtering with a tunable regularisation parameter. This method ensures all anisotropic features in the PSFs to be taken into account. We compare our method to existing procedures using measured Herschel/PACS and SPIRE PSFs and simulated JWST/MIRI PSFs. Significant gains up to two orders of magnitude are obtained with respect to the use of kernels computed assuming Gaussian or circularised PSFs. A software to compute these kernels is available at
Vertical Soil Profiling Using a Galvanic Contact Resistivity Scanning Approach
Pan, Luan; Adamchuk, Viacheslav I.; Prasher, Shiv; Gebbers, Robin; Taylor, Richard S.; Dabas, Michel
2014-01-01
Proximal sensing of soil electromagnetic properties is widely used to map spatial land heterogeneity. The mapping instruments use galvanic contact, capacitive coupling or electromagnetic induction. Regardless of the type of instrument, the geometrical configuration between signal transmitting and receiving elements typically defines the shape of the depth response function. To assess vertical soil profiles, many modern instruments use multiple transmitter-receiver pairs. Alternatively, vertical electrical sounding can be used to measure changes in apparent soil electrical conductivity with depth at a specific location. This paper examines the possibility for the assessment of soil profiles using a dynamic surface galvanic contact resistivity scanning approach, with transmitting and receiving electrodes configured in an equatorial dipole-dipole array. An automated scanner system was developed and tested in agricultural fields with different soil profiles. While operating in the field, the distance between current injecting and measuring pairs of rolling electrodes was varied continuously from 40 to 190 cm. The preliminary evaluation included a comparison of scan results from 20 locations to shallow (less than 1.2 m deep) soil profiles and to a two-layer soil profile model defined using an electromagnetic induction instrument. PMID:25057135
Ptolemy operations at the surface of a comet, from planning to reality
NASA Astrophysics Data System (ADS)
Morse, A. D.; Andrews, D. J.; Morgan, G. H.; Sheridan, S.; Barber, S. J.; Wright, I. P.
2016-08-01
Ptolemy is a Gas Chromatograph-Isotope Ratio-Mass Spectrometer (GC-IR-MS) aboard the Philae lander element of the Rosetta mission to comet 67P/Churyumov-Gerasimenko. Developed to determine the chemical and stable light isotopic composition of cometary material, Ptolemy was conceived as a highly flexible instrument able to accommodate changes in operational functionality via software modification. This was considered essential to allow for different modes of operation not only in response to rapid/unexpected changes and opportunities, but also to longer-term shifts in priorities as the overall mission plan (and indeed cometary science in general) changed during the decades from initial concept to landing. Against the backdrop of events of the Philae landing, this paper describes the methods of instrument operation and rational behind them used to achieve the Ptolemy scientific results during the period 12-14th November 2014. In particular we demonstrate the importance of a flexible modular approach to the instrument architecture enabling complex instrument operations, especially in a situation where the environment of exploration is effectively unknown and some of the engineering solutions were being tested in the field for the first time.
Quality Control of The Norwegian Uv Monitoring Network.
NASA Astrophysics Data System (ADS)
Johnsen, B.; Mikkelborg, O.; Dahlback, A.; Høiskar, B. A.; Kylling, A.; Edvardsen, K.; Olseth, J. A.; Kjeldstad, B.; Ørbæk, J. B.
A Norwegian UV-monitoring network of GUV multiband radiometers has been operating at locations between 59°N to 79°N since 1995-96. The purpose of the network is to obtain data of high scientific quality, to be used in further assessments related to health- and environmental issues. Maintenance of measurement quality is given priority. Spectral response functions, crucial for calibrations, have been obtained for each instrument. Calibrations are traceable to the Nordic intercomparison of UV radiometers held in Sweden in June 2000. Instruments are inspected daily or weekly. Once a year the instruments are compared to travelling standards operating side by side to the local network radiometers. This enables determination of the longterm drift in instrument responses. For the six years period of operation, the steadiest instrument performed stable within +/-3%, whereas the least steady had a response drop by 23%. Comparisons with a true cosine performing spectroradiometer demonstrate close agreement (+/- 2%) for solar zenith angles less than 80°. Good cosine performance, high spectral sensitivity and weatherproof design demonstrate that the GUV radiometers are particularly suitable for UV monitoring at high latitudes. Complete records of corrected daily CIE-effective doses and online measurements are presented on http://uvnett.nrpa.no/. Gaps in measurement series have been corrected for with a clear sky radiative transfer model and hourly UV sky transmittances estimated from pyranometer data. Measurement data and information about the monitoring network may be found by visiting websites at respectively NRPA, NILU and The University of Oslo; http://www.nrpa.no, http://www.nilu.no/uv, http://www.fys.uio.no/plasma/ozone/. At this stage the quality of the network has reached a satisfactory level and it is possible to move on using UV data in further assessments. Trend analyses and UV forecasting are topics for future work. The network is supported by the ministries of Health and Environment and is administered by The Norwegian Radiation Protection Authority and The Norwegian Pollution Control Authority, the latter through The Norwegian Institute for Air Research.
Space Weathering Perspectives on Europa Amidst the Tempest of the Jupiter Magnetospheric System
NASA Technical Reports Server (NTRS)
Cooper, J. F.; Hartle, R. E.; Lipatov, A. S.; Sittler, E. C.; Cassidy, T. A.; Ip. W.-H.
2010-01-01
Europa resides within a "perfect storm" tempest of extreme external field, plasma, and energetic particle interactions with the magnetospheric system of Jupiter. Missions to Europa must survive, functionally operate, make useful measurements, and return critical science data, while also providing full context on this ocean moon's response to the extreme environment. Related general perspectives on space weathering in the solar system are applied to mission and instrument science requirements for Europa.
The Behavioral Pharmacology of Effort-related Choice Behavior: Dopamine, Adenosine and Beyond
Salamone, John D; Correa, Merce; Nunes, Eric J; Randall, Patrick A; Pardo, Marta
2012-01-01
For many years, it has been suggested that drugs that interfere with dopamine (DA) transmission alter the “rewarding” impact of primary reinforcers such as food. Research and theory related to the functions of mesolimbic DA are undergoing a substantial conceptual restructuring, with the traditional emphasis on hedonia and primary reward yielding to other concepts and lines of inquiry. The present review is focused upon the involvement of nucleus accumbens DA in effort-related choice behavior. Viewed from the framework of behavioral economics, the effects of accumbens DA depletions and antagonism on food-reinforced behavior are highly dependent upon the work requirements of the instrumental task, and DA-depleted rats show a heightened sensitivity to response costs, especially ratio requirements. Moreover, interference with accumbens DA transmission exerts a powerful influence over effort-related choice behavior. Rats with accumbens DA depletions or antagonism reallocate their instrumental behavior away from food-reinforced tasks that have high response requirements, and show increased selection of low reinforcement/low cost options. Nucleus accumbens DA and adenosine interact in the regulation of effort-related functions, and other brain structures (anterior cingulate cortex, amygdala, ventral pallidum) also are involved. Studies of the brain systems regulating effort-based processes may have implications for understanding drug abuse, as well as symptoms such as psychomotor slowing, fatigue or anergia in depression and other neurological disorders. PMID:22287808
The behavioral pharmacology of effort-related choice behavior: dopamine, adenosine and beyond.
Salamone, John D; Correa, Merce; Nunes, Eric J; Randall, Patrick A; Pardo, Marta
2012-01-01
For many years, it has been suggested that drugs that interfere with dopamine (DA) transmission alter the "rewarding" impact of primary reinforcers such as food. Research and theory related to the functions of mesolimbic DA are undergoing a substantial conceptual restructuring, with the traditional emphasis on hedonia and primary reward yielding to other concepts and lines of inquiry. The present review is focused upon the involvement of nucleus accumbens DA in effort-related choice behavior. Viewed from the framework of behavioral economics, the effects of accumbens DA depletions and antagonism on food-reinforced behavior are highly dependent upon the work requirements of the instrumental task, and DA-depleted rats show a heightened sensitivity to response costs, especially ratio requirements. Moreover, interference with accumbens DA transmission exerts a powerful influence over effort-related choice behavior. Rats with accumbens DA depletions or antagonism reallocate their instrumental behavior away from food-reinforced tasks that have high response requirements, and show increased selection of low reinforcement/low cost options. Nucleus accumbens DA and adenosine interact in the regulation of effort-related functions, and other brain structures (anterior cingulate cortex, amygdala, ventral pallidum) also are involved. Studies of the brain systems regulating effort-based processes may have implications for understanding drug abuse, as well as symptoms such as psychomotor slowing, fatigue or anergia in depression and other neurological disorders.
The development of an instrument to assess chemistry perceptions
NASA Astrophysics Data System (ADS)
Wells, Raymond R.
The instrument, developed in this study, attempted to correct the deficiencies of previous instruments. Statements of belief and opinion can be validly included under the construct of chemistry perceptions. Further, statements that might be better characterized as science attitudes, math attitudes, or attitudes toward a specific course or program were not included. Eliminating statements of math anxiety and test anxiety insured that responses to statements of anxiety were perceptions of anxiety solely related to chemistry. The results of the expert judges' responses to the Validation of Proposed Perception Statements forms were detailed to establish construct and content validity. The nature of Likert scale construction and calculation of internal consistency also supported the validity of the instrument. A pilot Chemistry Perception Questionnaire (CPQ) was then constructed based on agreement of the appropriate subscale and mean importance of the perception statements. The pilot CPQ results were subjected to an item analysis based on three sets of statistics: the frequency of each response and the percentage of respondents making each response for each perception statement, the mean and standard deviations for each item, and the item discrimination index which correlated the item scores with the subscale scores. With no zero or negative correlations to the subscale scores, it was not necessary to replace any of the perception statements contained in the pilot instrument. Therefore, the piloted Chemistry Perception Questionnaire became the final instrument. Factor analysis confirmed the multidimensionality of the instrument. The instrument was administered twice with a separation interval of approximately one month in order to perform a test-retest reliability analysis. One hundred and forty-one pairs were matched and results detailed. The correlation between forms, for the total instrument, was 0.9342. The mean coefficient alpha, for the total instrument, was 0.9495. With test-retest correlations and alphas exceeding 0.70 for all seven subscales and the total instrument, it was determined that the Chemistry Perception Questionnaire instrument achieved reasonably high reliability estimations.
A Reminder of Extinction Reduces Relapse in an Animal Model of Voluntary Behavior
ERIC Educational Resources Information Center
Nieto, Javier; Uengoer, Metin; Bernal-Gamboa, Rodolfo
2017-01-01
One experiment with rats explored whether an extinction-cue prevents the recovery of extinguished lever-pressing responses. Initially, rats were trained to perform one instrumental response (R1) for food in Context A, and a different instrumental response (R2) in Context B. Then, responses were extinguished each in the alternate context (R1 in…
NASA Astrophysics Data System (ADS)
Irwanto, Rohaeti, Eli; LFX, Endang Widjajanti; Suyanta
2017-05-01
This research aims to develop instrument and determine the characteristics of an integrated assessment instrument. This research uses 4-D model, which includes define, design, develop, and disseminate. The primary product is validated by expert judgment, tested it's readability by students, and assessed it's feasibility by chemistry teachers. This research involved 246 students of grade XI of four senior high schools in Yogyakarta, Indonesia. Data collection techniques include interview, questionnaire, and test. Data collection instruments include interview guideline, item validation sheet, users' response questionnaire, instrument readability questionnaire, and essay test. The results show that the integrated assessment instrument has Aiken validity value of 0.95. Item reliability was 0.99 and person reliability was 0.69. Teachers' response to the integrated assessment instrument is very good. Therefore, the integrated assessment instrument is feasible to be applied to measure the students' analytical thinking and science process skills.
Exploiting IoT Technologies and Open Source Components for Smart Seismic Network Instrumentation
NASA Astrophysics Data System (ADS)
Germenis, N. G.; Koulamas, C. A.; Foundas, P. N.
2017-12-01
The data collection infrastructure of any seismic network poses a number of requirements and trade-offs related to accuracy, reliability, power autonomy and installation & operational costs. Having the right hardware design at the edge of this infrastructure, embedded software running inside the instruments is the heart of pre-processing and communication services implementation and their integration with the central storage and processing facilities of the seismic network. This work demonstrates the feasibility and benefits of exploiting software components from heterogeneous sources in order to realize a smart seismic data logger, achieving higher reliability, faster integration and less development and testing costs of critical functionality that is in turn responsible for the cost and power efficient operation of the device. The instrument's software builds on top of widely used open source components around the Linux kernel with real-time extensions, the core Debian Linux distribution, the earthworm and seiscomp tooling frameworks, as well as components from the Internet of Things (IoT) world, such as the CoAP and MQTT protocols for the signaling planes, besides the widely used de-facto standards of the application domain at the data plane, such as the SeedLink protocol. By using an innovative integration of features based on lower level GPL components of the seiscomp suite with higher level processing earthworm components, coupled with IoT protocol extensions to the latter, the instrument can implement smart functionality such as network controlled, event triggered data transmission in parallel with edge archiving and on demand, short term historical data retrieval.
Steeghs, Liana; van Vliet, Sandra J; Uronen-Hansson, Heli; van Mourik, Andries; Engering, Anneke; Sanchez-Hernandez, Martha; Klein, Nigel; Callard, Robin; van Putten, Jos P M; van der Ley, Peter; van Kooyk, Yvette; van de Winkel, Jan G J
2006-02-01
Neisseria meningitidis lipopolysaccharide (LPS) has been identified as a major determinant of dendritic cell (DC) function. Here we report that one of a series of meningococcal mutants with defined truncations in the lacto-N-neotetraose outer core of the LPS exhibited unique strong adhesion and internalization properties towards DC. These properties were mediated by interaction of the GlcNAc(beta1-3)-Gal(beta1-4)-Glc-R oligosaccharide outer core of lgtB LPS with the dendritic-cell-specific ICAM-3 grabbing non-integrin (DC-SIGN) lectin receptor. Activation of DC-SIGN with this novel oligosaccharide ligand skewed T-cell responses driven by DC towards T helper type 1 activity. Thus, the use of lgtB LPS may provide a powerful instrument to selectively induce the desired arm of the immune response and potentially increase vaccine efficacy.
XIMPOL: a new x-ray polarimetry observation-simulation and analysis framework
NASA Astrophysics Data System (ADS)
Omodei, Nicola; Baldini, Luca; Pesce-Rollins, Melissa; di Lalla, Niccolò
2017-08-01
We present a new simulation framework, XIMPOL, based on the python programming language and the Scipy stack, specifically developed for X-ray polarimetric applications. XIMPOL is not tied to any specific mission or instrument design and is meant to produce fast and yet realistic observation-simulations, given as basic inputs: (i) an arbitrary source model including morphological, temporal, spectral and polarimetric information, and (ii) the response functions of the detector under study, i.e., the effective area, the energy dispersion, the point-spread function and the modulation factor. The format of the response files is OGIP compliant, and the framework has the capability of producing output files that can be directly fed into the standard visualization and analysis tools used by the X-ray community, including XSPEC which make it a useful tool not only for simulating physical systems, but also to develop and test end-to-end analysis chains.
Alosco, Michael L; Brickman, Adam M; Spitznagel, Mary Beth; Narkhede, Atul; Griffith, Erica Y; Cohen, Ronald; Sweet, Lawrence H; Josephson, Richard; Hughes, Joel; Gunstad, John
2016-01-01
Heart failure patients require assistance with instrumental activities of daily living in part because of the high rates of cognitive impairment in this population. Structural brain insult (eg, reduced gray matter volume) is theorized to underlie cognitive dysfunction in heart failure, although no study has examined the association among gray matter, cognition, and instrumental activities of daily living in heart failure. The aim of this study was to investigate the associations among gray matter volume, cognitive function, and functional ability in heart failure. A total of 81 heart failure patients completed a cognitive test battery and the Lawton-Brody self-report questionnaire to assess instrumental activities of daily living. Participants underwent magnetic resonance imaging to quantify total gray matter and subcortical gray matter volume. Impairments in instrumental activities of daily living were common in this sample of HF patients. Regression analyses controlling for demographic and medical confounders showed that smaller total gray matter volume predicted decreased scores on the instrumental activities of daily living composite, with specific associations noted for medication management and independence in driving. Interaction analyses showed that reduced total gray matter volume interacted with worse attention/executive function and memory to negatively impact instrumental activities of daily living. Smaller gray matter volume is associated with greater impairment in instrumental activities of daily living in persons with heart failure, possibly via cognitive dysfunction. Prospective studies are needed to clarify the utility of clinical correlates of gray matter volume (eg, cognitive dysfunction) in identifying heart failure patients at risk for functional decline and determine whether interventions that target improved brain and cognitive function can preserve functional independence in this high-risk population.
Instrumentation for Non-Invasive Assessment of Cardiovascular Regulation
NASA Technical Reports Server (NTRS)
Cohen, Richard J.
1999-01-01
It is critically important to be able to assess alterations in cardiovascular regulation during and after space flight. We propose to develop an instrument for the non-invasive assessment of such alterations that can be used on the ground and potentially during space flight. This instrumentation would be used by the Cardiovascular Alterations Team at multiple sites for the study of the effects of space flight on the cardiovascular system and the evaluation of countermeasures. In particular, the Cardiovascular Alterations Team will use this instrumentation in conjunction with ground-based human bed-rest studies and during application of acute stresses e.g., tilt, lower body negative pressure, and exercise. In future studies, the Cardiovascular Alterations Team anticipates using this instrumentation to study astronauts before and after space flight and ultimately, during space flight. The instrumentation may also be used by the Bone Demineralization/Calcium Metabolism Team, the Neurovestibular Team and the Human Performance Factors, Sleep and Chronobiology Team to measure changes in autonomic nervous function. The instrumentation will be based on a powerful new technology - cardiovascular system identification (CSI) - which has been developed in our laboratory. CSI provides a non-invasive approach for the study of alterations in cardiovascular regulation. This approach involves the analysis of second-to-second fluctuations in physiologic signals such as heart rate and non-invasively measured arterial blood pressure in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of multiple physiologic mechanisms, CSI provides a closed-loop model of the cardiovascular regulatory state in an individual subject.
White-Schwoch, Travis; Woodruff Carr, Kali; Anderson, Samira; Strait, Dana L; Kraus, Nina
2013-11-06
Aging results in pervasive declines in nervous system function. In the auditory system, these declines include neural timing delays in response to fast-changing speech elements; this causes older adults to experience difficulty understanding speech, especially in challenging listening environments. These age-related declines are not inevitable, however: older adults with a lifetime of music training do not exhibit neural timing delays. Yet many people play an instrument for a few years without making a lifelong commitment. Here, we examined neural timing in a group of human older adults who had nominal amounts of music training early in life, but who had not played an instrument for decades. We found that a moderate amount (4-14 years) of music training early in life is associated with faster neural timing in response to speech later in life, long after training stopped (>40 years). We suggest that early music training sets the stage for subsequent interactions with sound. These experiences may interact over time to sustain sharpened neural processing in central auditory nuclei well into older age.
White-Schwoch, Travis; Carr, Kali Woodruff; Anderson, Samira; Strait, Dana L.
2013-01-01
Aging results in pervasive declines in nervous system function. In the auditory system, these declines include neural timing delays in response to fast-changing speech elements; this causes older adults to experience difficulty understanding speech, especially in challenging listening environments. These age-related declines are not inevitable, however: older adults with a lifetime of music training do not exhibit neural timing delays. Yet many people play an instrument for a few years without making a lifelong commitment. Here, we examined neural timing in a group of human older adults who had nominal amounts of music training early in life, but who had not played an instrument for decades. We found that a moderate amount (4–14 years) of music training early in life is associated with faster neural timing in response to speech later in life, long after training stopped (>40 years). We suggest that early music training sets the stage for subsequent interactions with sound. These experiences may interact over time to sustain sharpened neural processing in central auditory nuclei well into older age. PMID:24198359
NPP VIIRS Geometric Performance Status
NASA Technical Reports Server (NTRS)
Lin, Guoqing; Wolfe, Robert E.; Nishihama, Masahiro
2011-01-01
Visible Infrared Imager Radiometer Suite (VIIRS) instrument on-board the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) satellite is scheduled for launch in October, 2011. It is to provide satellite measured radiance/reflectance data for both weather and climate applications. Along with radiometric calibration, geometric characterization and calibration of Sensor Data Records (SDRs) are crucial to the VIIRS Environmental Data Record (EDR) algorithms and products which are used in numerical weather prediction (NWP). The instrument geometric performance includes: 1) sensor (detector) spatial response, parameterized by the dynamic field of view (DFOV) in the scan direction and instantaneous FOV (IFOV) in the track direction, modulation transfer function (MTF) for the 17 moderate resolution bands (M-bands), and horizontal spatial resolution (HSR) for the five imagery bands (I-bands); 2) matrices of band-to-band co-registration (BBR) from the corresponding detectors in all band pairs; and 3) pointing knowledge and stability characteristics that includes scan plane tilt, scan rate and scan start position variations, and thermally induced variations in pointing with respect to orbital position. They have been calibrated and characterized through ground testing under ambient and thermal vacuum conditions, numerical modeling and analysis. This paper summarizes the results, which are in general compliance with specifications, along with anomaly investigations, and describes paths forward for characterizing on-orbit BBR and spatial response, and for improving instrument on-orbit performance in pointing and geolocation.
Strong motion instrumentation of an RC building structure
Li, H.-J.; Celebi, M.
2001-01-01
The strong-motion instrumentation scheme of a reinforced concrete building observed by California Strong-Motion Instrumentation Program (CSMIP) is introduced in this paper. The instrumented building is also described and the recorded responses during 1994 Northridge earthquake are provided.
Prospective study of recovery from copperhead snake envenomation: an observational study.
Lavonas, Eric J; Gerardo, Charles J
2015-05-15
Although much is known about signs, symptoms, and management in the acute phase of crotaline snake envenomation, little is known about signs, symptoms, function, and quality of life during the recovery phase. The purpose of this observational pilot investigation is to evaluate the utility of several clinical outcome instruments in the setting of copperhead snakebite, and to characterize the clinical course of recovery. This is a multi-center prospective, open-label, observational study of patients envenomated by copperhead snakes. We administered the Disabilities of the Arm, Shoulder, and Hand (DASH), Lower Extremity Functional Scale (LEFS), Patient-Specific Functional Scale (PSFS), Work Productivity and Ability Impairment: Special Health Problem (WPAI: SHP), Patients' Global Impression of Change (PGIC), Patient's Global Assessment of Recovery (PGAR), and SF-36 instruments, obtained numeric pain rating scales, and measured grip strength, walking speed, and swelling prior to hospital discharge and 3, 7, 14, 21, and 28 days after envenomation. 20 subjects were enrolled; none were lost to follow-up. Most (80%) had moderate severity swelling, and most (75%) received antivenom. Across the broad range of measures, abnormalities of pain, swelling, impairments of physical and role function, and quality of life persisted for 7-14 days in most subjects. Validated self-reported outcome measures, such as the DASH, LEFS, PSFS, PGIC, SF-36, and the daily activities impairment portion of the WPAI: SHP were more responsive than measurements of swelling or walking speed. Data quality issues limited the utility of the work impairment portion of the WPAI: SHP. Residual signs, symptoms, and impairment in some subjects lasted through the 28-day study period. The study design precluded any assessment of the effectiveness of antivenom. Signs, symptoms, impaired function, and decreased quality of life typically last 7 - 14 days after copperhead envenomation. Several tools appear responsive and useful in studying recovery from pit viper envenomation. ClinicalTrials.gov NCT01651299.
Instrumentation and Controls Division progress report for the period July 1, 1986 to June 30, 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klobe, L.E.
1988-12-01
The Instrumentation and Controls (IandC) Division of Oak Ridge National Laboratory (ORNL) performs basic and applied instrumentation and controls research, development and design engineering, specialized instrument design and fabrication, and maintenance services for instruments, electronics, and computers. The IandC Division is one of the largest RandD organizations of its type among government laboratories, and it exists as the result of an organizational strategy to integrate ORNL's instrumentation and controls-related disciplines into one dedicated functional organization to increase the Laboratory's expertise and capabilities in these rapidly expanding, innovative areas of technology. The Division participates in the programs and projects of ORNLmore » by applying its expertise and capabilities in concert with other divisions to perform basic research and mission-oriented technology development. Many of the Division's RandD tasks that are a part of a larger ORNL program are of sufficient scope that the IandC effort constitutes a separate program element with direct funding and management responsibility within the Division. The activities of IandC include performance of an RandD task in IandC facilities, the participation of from one of many IandC engineers and scientists in a multidisciplinary team working in a specific research area or development project, design and fabrication of a special instrument or instrumentation system, or a few hours of maintenance service. In its support and maintenance work, the role of the IandC Division is to provide a level of expertise appropriate to complete a job successfully at minimum overall cost and time schedule---a role which involves IandC in almost all ORNL activities.« less
NASA Technical Reports Server (NTRS)
Benner, D. Chris
1998-01-01
This cooperative agreement has investigated a number of spectroscopic problems of interest to the Halogen Occultation Experiment (HALOE). The types of studies performed are in two parts, namely, those that involve the testing and characterization of correlation spectrometers and those that provide basic molecular spectroscopic information. In addition, some solar studies were performed with the calibration data returned by HALOE from orbit. In order to accomplish this a software package was written as part of this cooperative agreement. The HALOE spectroscopic instrument package was used in various tests of the HALOE flight instrument. These included the spectral response test, the early stages of the gas response test and various spectral response tests of the detectors and optical elements of the instruments. Considerable effort was also expended upon the proper laboratory setup for many of the prelaunch tests of the HALOE flight instrument, including the spectral response test and the gas response test. These tests provided the calibration and the assurance that the calibration was performed correctly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peabody, C.O.
1963-12-01
Measurements were made of the response of five commonly used health physics instruments when held near polythene man-phantoms filled with aqueous solutions containing sodium-24 and chlorine-38. The ratios of the wholebody chlorine-38 and sodium-24 activities are calculated for various periods of accidental human irradiation by neutrons. These ratios and the phantom results are used to estimate the response of the five instruments when held near the human body at various times after irradiation. Relative contributions of the chlorine-38 and sodium-24 to the instrument indications are listed. The tabulated data enable the instrument readings to be converted to wholebody sodium- 24more » activity at the time of irradiation. This may be used as a quick estimate of the degree of neutron irradiation. (auth)« less
Paz, Sylvia H.; Jones, Loretta; Calderón, José L.; Hays, Ron D.
2016-01-01
Background Depression and physical function are especially important health domains for the elderly. The Geriatric Depression Scale (GDS) and the Patient-Reported Outcomes Measurement Information System (PROMIS®) Physical Function Item Bank are two surveys commonly used to measure these domains. It is unclear if these two instruments adequately measure these aspects of health in minority elderly. Objective To estimate the readability of the GDS and PROMIS® Physical Function items and to assess their comprehensibility by a sample of African American and Latino elderly. Methods Readability was estimated using the Flesch-Kincaid (F-K) and Flesch-Reading-Ease (FRE) formulae for English versions, and a Spanish adaptation of the FRE formula for the Spanish versions. Comprehension of the GDS and PROMIS items by minority elderly was evaluated with 30 cognitive interviews. Results Readability estimates of a number of items in English and Spanish of the GDS and PROMIS physical functioning items exceed the recommended 5th grade level, or were rated as fairly difficult, difficult, or very difficult to read. Cognitive interviews revealed that many participants felt that more than the two (yes/no) GDS response options were needed to answer the questions. Wording of several PROMIS items was considered confusing and responses potentially uninterpretable because they were based on physical aids. Conclusions Problems with item wording and response options of the GDS and PROMIS Physical Function items may negatively affect reliability and validity of measurement when used with minority elderly. PMID:27599978
Surgical Robotics Research in Cardiovascular Disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pohost, Gerald M; Guthrie, Barton L; Steiner, Charles
This grant is to support a research in robotics at three major medical centers: the University of Southern California-USC- (Project 1); the University of Alabama at Birmingham-UAB-(Project 2); and the Cleveland Clinic Foundation-CCF-(Project 3). Project 1 is oriented toward cardiovascular applications, while projects 2 and 3 are oriented toward neurosurgical applications. The main objective of Project 1 is to develop an approach to assist patients in maintaining a constant level of stress while undergoing magnetic resonance imaging or spectroscopy. The specific project is to use handgrip to detect the changes in high energy phosphate metabolism between rest and stress. Themore » high energy phosphates, ATP and phosphocreatine (PCr) are responsible for the energy of the heart muscle (myocardium) responsible for its contractile function. If the blood supply to the myocardium in insufficient to support metabolism and contractility during stress, the high energy phosphates, particularly PCr, will decrease in concentration. The high energy phosphates can be tracked using phosphorus-31 magnetic resonance spectroscopy ({sup 31}P MRS). In Project 2 the UAB Surgical Robotics project focuses on the use of virtual presence to assist with remote surgery and surgical training. The goal of this proposal was to assemble a pilot system for proof of concept. The pilot project was completed successfully and was judged to demonstrate that the concept of remote surgical assistance as applied to surgery and surgical training was feasible and warranted further development. The main objective of Project 3 is to develop a system to allow for the tele-robotic delivery of instrumentation during a functional neurosurgical procedure (Figure 3). Instrumentation such as micro-electrical recording probes or deep brain stimulation leads. Current methods for the delivery of these instruments involve the integration of linear actuators to stereotactic navigation systems. The control of these delivery devices utilizes an open-loop configuration involving a team consisting of neurosurgeon, neurologist and neurophysiologist all present and participating in the decision process of delivery. We propose the development of an integrated system which provides for distributed decision making and tele-manipulation of the instrument delivery system.« less
Montpetit, Kathleen; Haley, Stephen; Bilodeau, Nathalie; Ni, Pengsheng; Tian, Feng; Gorton, George; Mulcahey, M J
2011-02-01
This article reports on the content range and measurement precision of an upper extremity (UE) computer adaptive testing (CAT) platform of physical function in children with cerebral palsy. Upper extremity items representing skills of all abilities were administered to 305 parents. These responses were compared with two traditional standardized measures: Pediatric Outcomes Data Collection Instrument and Functional Independence Measure for Children. The UE CAT correlated strongly with the upper extremity component of these measures and had greater precision when describing individual functional ability. The UE item bank has wider range with items populating the lower end of the ability spectrum. This new UE item bank and CAT have the capability to quickly assess children of all ages and abilities with good precision and, most importantly, with items that are meaningful and appropriate for their age and level of physical function.
Arcoverde, Cynthia; Deslandes, Andrea; Moraes, Helena; Almeida, Cloyra; Araujo, Narahyana Bom de; Vasques, Paulo Eduardo; Silveira, Heitor; Laks, Jerson
2014-03-01
To assess the effect of aerobic exercise on the cognition and functional capacity in Alzheimer's disease (AD) patients. Elderly (n=20) with mild dementia (NINCDS-ADRDA/CDR1) were randomly assigned to an exercise group (EG) on a treadmill (30 minutes, twice a week and moderate intensity of 60% VO₂max) and control group (GC) 10 patients. The primary outcome measure was the cognitive function using Cambridge Cognitive Examination (CAMCOG). Specifics instruments were also applied to evaluate executive function, memory, attention and concentration, cognitive flexibility, inhibitory control and functional capacity. After 16 weeks, the EG showed improvement in cognition CAMCOG whereas the CG declined. Compared to the CG, the EG presented significant improvement on the functional capacity. The analysis of the effect size has shown a favorable response to the physical exercise in all dependent variables. Walking on treadmill may be recommended as an augmentation treatment for patients with AD.
On the Measurement of Power Law Creep Parameters from Instrumented Indentation
NASA Astrophysics Data System (ADS)
Sudharshan Phani, P.; Oliver, W. C.; Pharr, G. M.
2017-11-01
Recently the measurement of the creep response of materials at small scales has received renewed interest largely because the equipment required to perform high-temperature nanomechanical testing has become available to an increasing number of researchers. Despite that increased access, there remain several significant experimental and modeling challenges in small-scale mechanical testing at elevated temperatures that are as yet unresolved. In this regard, relating the creep response observed with high-temperature instrumented indentation experiments to macroscopic uniaxial creep response is of great practical value. In this review, we present an overview of various methods currently being used to measure creep with instrumented indentation, with a focus on geometrically self-similar indenters, and their relative merits and demerits from an experimental perspective. A comparison of the various methods to use those instrumented indentation results to predict the uniaxial power law creep response of a wide range of materials will be presented to assess their validity.
Abdel, Matthew P; Parratte, Sébastien; Blanc, Guillaume; Ollivier, Matthieu; Pomero, Vincent; Viehweger, Elke; Argenson, Jean-Noël A
2014-08-01
Although some clinical reports suggest patient-specific instrumentation in TKA may improve alignment, reduce surgical time, and lower hospital costs, it is unknown whether it improves pain- and function-related outcomes and gait. We hypothesized that TKA performed with patient-specific instrumentation would improve patient-reported outcomes measured by validated scoring tools and level gait as ascertained with three-dimensional (3-D) analysis compared with conventional instrumentation 3 months after surgery. We randomized 40 patients into two groups using either patient-specific instrumentation or conventional instrumentation. Patients were evaluated preoperatively and 3 months after surgery. Assessment tools included subjective functional outcome and quality-of-life (QOL) scores using validated questionnaires (New Knee Society Score(©) [KSS], Knee Injury and Osteoarthritis Outcome Score [KOOS], and SF-12). In addition, gait analysis was evaluated with a 3-D system during level walking. The study was powered a priori at 90% to detect a difference in walking speed of 0.1 m/second, which was considered a clinically important difference, and in a post hoc analysis at 80% to detect a difference of 10 points in KSS. There were improvements from preoperatively to 3 months postoperatively in functional scores, QOL, and knee kinematic and kinetic gait parameters during level walking. However, there was no difference between the patient-specific instrumentation and conventional instrumentation groups in KSS, KOOS, SF-12, or 3-D gait parameters. Our observations suggest that patient-specific instrumentation does not confer a substantial advantage in early functional or gait outcomes after TKA. It is possible that differences may emerge, and this study does not allow one to predict any additional variances in the intermediate followup period from 6 months to 1 year postoperatively. However, the goals of the study were to investigate the recovery period as early pain and functional outcomes are becoming increasingly important to patients and surgeons. Level I, therapeutic study. See the Instructions to Authors for a complete description of levels of evidence.
Lin, Chih-Ju; Lee, Sheng-Lin; Lee, Hsuan-Shu; Dong, Chen-Yuan
2018-06-01
We used intravital multiphoton microscopy to study the recovery of hepatobiliary metabolism following carbon tetrachloride (CCl4) induced hepatotoxicity in mice. The acquired images were processed by a first order kinetic model to generate rate constant resolved images of the mouse liver. We found that with progression of hepatotoxicity, the spatial gradient of hepatic function disappeared. A CCl4-induced damage mechanism involves the compromise of membrane functions, resulting in accumulation of processed 6-carboxyfluorescein molecules. At day 14 following induction, a restoration of the mouse hepatobiliary function was found. Our approach allows the study of the response of hepatic functions to chemical agents in real time and is useful for studying pharmacokinetics of drug molecules through optical microscopic imaging. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
MOEMs-based new functionalities for future instrumentation in space
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Liotard, Arnaud; Viard, Thierry; Costes, Vincent; Hébert, Philippe-Jean; Hinglais, Emmanuel; Villenave, Michel
2017-11-01
Micro-Opto-Electro-Mechanical Systems (MOEMS) could be key components in future generation of space instruments. In Earth Observation, Universe Observation and Planet Exploration, scientific return of the instruments must be optimized in future missions. MOEMS devices are based on the mature micro-electronics technology and in addition to their compactness, scalability, and specific task customization, they could generate new functions not available with current technologies. CNES has initiated a study with LAM and TAS for listing the new functions associated with several types of MEMS (programmable slits, programmable micro-diffraction gratings, micro-deformable mirrors). Instrumental applications are then derived and promising concepts are described.
SeaWiFS Technical Report Series. Volume 39; SeaWiFS Calibration Topics
NASA Technical Reports Server (NTRS)
Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Barnes, Robert A.; Yeh, Eueng-nan; Eplee, Robert E.
1996-01-01
For Earth-observing satellite instruments, it was standard to consider each instrument band to have a spectral response that is infinitely narrow, i.e., to have a response from a single wavelength. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) bands, however, have nominal spectral bandwidths of 20 and 40nm. These bandwidths affect the SeaWiFS measurements on orbit. The effects are also linked to the manner in which the instrument was calibrated and to the spectral shape of the radiance that SeaWiFS views. Currently, SeaWiFS is calibrated such that the digital counts from each instrument band are linked to the Earth-exiting radiance at an individual center wavelength. Before launch, SeaWiFS will be recalibrated so that the digital counts from each band will be linked to the Earth-exiting radiance integrated over the spectral response of that band. In this technical memorandum, the effects of the instrument calibration and the source spectral shape on SeaWiFS measurements, including the in-band and out-of-band responses, and the center wavelengths are discussed.
NASA Astrophysics Data System (ADS)
Wallis, Eric; Griffin, Todd M.; Popkie, Norm, Jr.; Eagan, Michael A.; McAtee, Robert F.; Vrazel, Danet; McKinly, Jim
2005-05-01
Ion Mobility Spectroscopy (IMS) is the most widespread detection technique in use by the military for the detection of chemical warfare agents, explosives, and other threat agents. Moreover, its role in homeland security and force protection has expanded due, in part, to its good sensitivity, low power, lightweight, and reasonable cost. With the increased use of IMS systems as continuous monitors, it becomes necessary to develop tools and methodologies to ensure optimal performance over a wide range of conditions and extended periods of time. Namely, instrument calibration is needed to ensure proper sensitivity and to correct for matrix or environmental effects. We have developed methodologies to deal with the semi-quantitative nature of IMS and allow us to generate response curves that allow a gauge of instrument performance and maintenance requirements. This instrumentation communicates to the IMS systems via a software interface that was developed in-house. The software measures system response, logs information to a database, and generates the response curves. This paper will discuss the instrumentation, software, data collected, and initial results from fielded systems.
Bennett, Antonia V; Keenoy, Kathleen; Shouery, Marwan; Basch, Ethan; Temple, Larissa K
2016-05-01
To assess the equivalence of patient-reported outcome (PRO) survey responses across Web, interactive voice response system (IVRS), and paper modes of administration. Postoperative colorectal cancer patients with home Web/e-mail and phone were randomly assigned to one of the eight study groups: Groups 1-6 completed the survey via Web, IVRS, and paper, in one of the six possible orders; Groups 7-8 completed the survey twice, either by Web or by IVRS. The 20-item survey, including the MSKCC Bowel Function Instrument (BFI), the LASA Quality of Life (QOL) scale, and the Subjective Significance Questionnaire (SSQ) adapted to bowel function, was completed from home on consecutive days. Mode equivalence was assessed by comparison of mean scores across modes and intraclass correlation coefficients (ICCs) and was compared to the test-retest reliability of Web and IVRS. Of 170 patients, 157 completed at least one survey and were included in analysis. Patients had mean age 56 (SD = 11), 53% were male, 81% white, 53% colon, and 47% rectal cancer; 78% completed all assigned surveys. Mean scores for BFI total score, BFI subscale scores, LASA QOL, and adapted SSQ varied by mode by less than one-third of a score point. ICCs across mode were: BFI total score (Web-paper = 0.96, Web-IVRS = 0.97, paper-IVRS = 0.97); BFI subscales (range = 0.88-0.98); LASA QOL (Web-paper = 0.98, Web-IVRS = 0.78, paper-IVRS = 0.80); and SSQ (Web-paper = 0.92, Web-IVRS = 0.86, paper-IVRS = 0.79). Mode equivalence was demonstrated for the BFI total score, BFI subscales, LASA QOL, and adapted SSQ, supporting the use of multiple modes of PRO data capture in clinical trials.
Transient hot-film sensor response in a shock tube
NASA Technical Reports Server (NTRS)
Roberts, A. S., Jr.; Ortgies, K. R.; Gartenberg, E.
1989-01-01
Shock tube experiments were performed to determine the response of a hot-film sensor, mounted flush on the side wall of a shock tube, to unsteady flow behind a normal shock wave. The present experiments attempt to isolate the response of the anemometer due only to the change in convective heat transfer at the hot-film surface. The experiments, performed at low supersonic shock speeds in air, are described along with the data acquisition procedure. The change in convective heat transfer is deduced from the data and the results are compared with those from transient boundary layer theory and another set of experimental results. Finally, a transient local heat transfer coefficient is formulated for use as the forcing function in a hot-film sensor instrument model simulation.
NASA Technical Reports Server (NTRS)
Kelley, N. D.; Mckenna, H. E.; Jacobs, E. W.
1995-01-01
Early results from a recent experiment designed to directly evaluate the aeroacoustic/elastic spectral responses of a MOD-2 turbine blade to turbulence-induced unsteady blade loads are discussed. The experimental procedure consisted of flying a hot-film anemometer from a tethered balloon in the turbine inflow and simultaneously measuring the fluctuating airload and aeroelastic response at two blade span stations (65% and 87% spans) using surface-mounted, subminiature pressure transducers and standard strain gage instrumentation. The radiated acoustic pressure field was measured with a triad of very-low-frequency microphones placed at ground level, 1.5 rotor diameters upwind of the disk. Initial transfer function estimates for acoustic radiation, blade normal forces, flapwise acceleration/displacement, and chord/flapwise moments are presented.
Roos, Ewa M.; Engelhart, Luella; Ranstam, Jonas; Anderson, Allen F.; Irrgang, Jay J.; Marx, Robert G.; Tegner, Yelverton; Davis, Aileen M.
2011-01-01
Objective: The purpose of this article is to describe and recommend patient-reported outcome instruments for use in patients with articular cartilage lesions undergoing cartilage repair interventions. Methods: Nonsystematic literature search identifying measures addressing pain and function evaluated for validity and psychometric properties in patients with articular cartilage lesions. Results: The knee-specific instruments, titled the International Knee Documentation Committee Subjective Knee Form and the Knee injury and Osteoarthritis and Outcome Score, both fulfill the basic requirements for reliability, validity, and responsiveness in cartilage repair patients. A major difference between them is that the former results in a single score and the latter results in 5 subscores. A single score is preferred for simplicity’s sake, whereas subscores allow for evaluation of separate constructs at all levels according to the International Classification of Functioning. Conclusions: Because there is no obvious superiority of either instrument at this time, both outcome measures are recommended for use in cartilage repair. Rescaling of the Lysholm Scoring Scale has been suggested, and confirmatory longitudinal studies are needed prior to recommending this scale for use in cartilage repair. Inclusion of a generic measure is feasible in cartilage repair studies and allows analysis of health-related quality of life and health economic outcomes. The Marx or Tegner Activity Rating Scales are feasible and have been evaluated in patients with knee injuries. However, activity measures require age and sex adjustment, and data are lacking in people with cartilage repair. PMID:26069575
Seither-Preisler, Annemarie; Parncutt, Richard; Schneider, Peter
2014-08-13
Playing a musical instrument is associated with numerous neural processes that continuously modify the human brain and may facilitate characteristic auditory skills. In a longitudinal study, we investigated the auditory and neural plasticity of musical learning in 111 young children (aged 7-9 y) as a function of the intensity of instrumental practice and musical aptitude. Because of the frequent co-occurrence of central auditory processing disorders and attentional deficits, we also tested 21 children with attention deficit (hyperactivity) disorder [AD(H)D]. Magnetic resonance imaging and magnetoencephalography revealed enlarged Heschl's gyri and enhanced right-left hemispheric synchronization of the primary evoked response (P1) to harmonic complex sounds in children who spent more time practicing a musical instrument. The anatomical characteristics were positively correlated with frequency discrimination, reading, and spelling skills. Conversely, AD(H)D children showed reduced volumes of Heschl's gyri and enhanced volumes of the plana temporalia that were associated with a distinct bilateral P1 asynchrony. This may indicate a risk for central auditory processing disorders that are often associated with attentional and literacy problems. The longitudinal comparisons revealed a very high stability of auditory cortex morphology and gray matter volumes, suggesting that the combined anatomical and functional parameters are neural markers of musicality and attention deficits. Educational and clinical implications are considered. Copyright © 2014 the authors 0270-6474/14/3410937-13$15.00/0.
Pavlovian to instrumental transfer of control in a human learning task.
Nadler, Natasha; Delgado, Mauricio R; Delamater, Andrew R
2011-10-01
Pavlovian learning tasks have been widely used as tools to understand basic cognitive and emotional processes in humans. The present studies investigated one particular task, Pavlovian-to-instrumental transfer (PIT), with human participants in an effort to examine potential cognitive and emotional effects of Pavlovian cues upon instrumentally trained performance. In two experiments, subjects first learned two separate instrumental response-outcome relationships (i.e., R1-O1 and R2-O2) and then were exposed to various stimulus-outcome relationships (i.e., S1-O1, S2-O2, S3-O3, and S4-) before the effects of the Pavlovian stimuli on instrumental responding were assessed during a non-reinforced test. In Experiment 1, instrumental responding was established using a positive-reinforcement procedure, whereas in Experiment 2, a quasi-avoidance learning task was used. In both cases, the Pavlovian stimuli exerted selective control over instrumental responding, whereby S1 and S2 selectively elevated the instrumental response with which it shared an outcome. In addition, in Experiment 2, S3 exerted a nonselective transfer of control effect, whereby both responses were elevated over baseline levels. These data identify two ways, one specific and one general, in which Pavlovian processes can exert control over instrumental responding in human learning paradigms, suggesting that this method may serve as a useful tool in the study of basic cognitive and emotional processes in human learning.
Pavlovian to Instrumental Transfer of Control in a Human Learning Task
Nadler, Natasha; Delgado, Mauricio R.; Delamater, Andrew R.
2011-01-01
Pavlovian learning tasks have been widely used as tools to understand basic cognitive and emotional processes in humans. The present studies investigated one particular task, Pavlovian-to-instrumental transfer (PIT), with human participants in an effort to examine potential cognitive and emotional effects of Pavlovian cues upon instrumentally-trained performance. In two experiments subjects first learned two separate instrumental response-outcome relationships (R1-O1, R2-O2) and then were exposed to various stimulus-outcome relationships (S1-O1, S2-O2, S3-O3, S4-) before the effects of the Pavlovian stimuli on instrumental responding were assessed during a nonreinforced test. In Experiment 1 instrumental responding was established using a positive reinforcement procedure whereas in Experiment 2 a quasi-avoidance learning task was used. In both cases the Pavlovian stimuli exerted selective control over instrumental responding, whereby S1 & S2 selectively elevated the instrumental response with which it shared an outcome. In addition, in Experiment 2, S3 exerted a nonselective transfer of control effect, whereby both responses were elevated over baseline levels. These data identify two ways, one specific and one general, in which Pavlovian processes can exert control over instrumental responding in human learning paradigms, and suggest that this method may serve as a useful tool in the study of basic cognitive and emotional processes in human learning. PMID:21534664
Bulcun, Emel; Arslan, Mesut; Ekici, Aydanur; Ekici, Mehmet
2015-11-01
Bronchiectasis can adversely affect quality of life. However, the tests examining quality of life in bronchiectasis are not sufficient. We examined the validity of a measure designed for COPD, the Seattle Obstructive Lung Disease Questionnaire (SOLQ), in bronchiectasis. In addition, we aimed to compare the quality of life of subjects with bronchiectasis and bronchial hyper-responsiveness with that of those without to identify the effective factors. We studied 78 subjects with clinically stable bronchiectasis and 41 healthy controls matched for age and sex. Subjects were assessed by the SOLQ. A detailed history, physical examination, the Medical Outcomes Study 36-Item Short Form questionnaire, the Hospital Anxiety and Depression Scale, and spirometric measurements were obtained. Cronbach α coefficients, which reflected internal consistency, were >0.70 for all SOLQ components except for treatment satisfaction. SOLQ component scores correlated with all of the component scores of the Medical Outcomes Study 36-Item Short Form questionnaire and the Hospital Anxiety and Depression Scale, confirming their concurrent validity. All SOLQ scores correlated positively with percent-of-predicted FEV1, whereas the physical function, treatment satisfaction, and emotional function correlated negatively with the exacerbation frequency in Pearson analysis. Emotional and physical functions were positively associated with percent-of-predicted FEV1 in linear regression analysis. Compared with subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had lower FEV1/FVC and more exacerbations/y. Compared with bronchiectasis subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had significantly lower SOLQ, physical function, and coping skills scores but not emotional function and treatment satisfaction. The SOLQ is a valid instrument for determining quality of life in subjects with bronchiectasis. Subjects with bronchiectasis and bronchial hyper-responsiveness had a poorer quality of life, lower baseline spirometric values, and more frequent exacerbations, suggesting more severe disease. Copyright © 2015 by Daedalus Enterprises.
Zhou, Kaina; Zhuang, Guihua; Zhang, Hongmei; Liang, Peifeng; Yin, Juan; Kou, Lingling; Hao, Mengmeng; You, Lijuan
2013-01-01
To test psychometrics of the Short Form 36 Health Survey version 2 (SF-36v2) and the Quality of Life Scale for Drug Addicts (QOL-DAv2.0) in Chinese mainland patients with methadone maintenance treatment (MMT). A total of 1,212 patients were recruited from two MMT clinics in Xi'an, China. Reliability was estimated with Cronbach's α and intra-class correlation (ICC). Convergent and discriminant validity was assessed using multitrait-multimethod correlation matrix. Sensitivity was measured with ANOVA and relative efficiency. Responsiveness was evaluated by pre-post paired-samples t-test and standardized response mean based on the patients' health status changes following 6-month period. Cronbach's α of the SF-36v2 physical and mental summary components were 0.80 and 0.86 (eight scales range 0.73-0.92) and the QOL-DAv2.0 was 0.96 (four scales range: 0.80-0.93). ICC of the SF-36v2 two components were 0.86 and 0.85 (eight scales range: 0.72-0.87) and the QOL-DAv2.0 was 0.94 (four scales range: 0.88-0.92). Convergent validity was lower between the two instruments (γ <0.70) while discriminant validity was acceptable within each instrument. Sensitivity was satisfied in self-evaluated health status (both instruments) and average daily methadone dose (SF-36v2 physical functioning and vitality scales; QOL-DAv2.0 except psychology scale). Responsiveness was acceptable in the improved health status change (SF-36v2 except vitality scale; QOL-DAv2.0 except psychology and symptoms scales) and deteriorated health status change (SF-36v2 except vitality, social functioning and mental health scales; QOL-DAv2.0 except society scale). The SF-36v2 and the QOL-DAv2.0 are valid tools and can be used independently or complementary according to different emphases of health-related quality of life evaluation in patients with MMT.
Zhou, Kaina; Zhuang, Guihua; Zhang, Hongmei; Liang, Peifeng; Yin, Juan; Kou, Lingling; Hao, Mengmeng; You, Lijuan
2013-01-01
Objective To test psychometrics of the Short Form 36 Health Survey version 2 (SF-36v2) and the Quality of Life Scale for Drug Addicts (QOL-DAv2.0) in Chinese mainland patients with methadone maintenance treatment (MMT). Methods A total of 1,212 patients were recruited from two MMT clinics in Xi’an, China. Reliability was estimated with Cronbach’s α and intra-class correlation (ICC). Convergent and discriminant validity was assessed using multitrait-multimethod correlation matrix. Sensitivity was measured with ANOVA and relative efficiency. Responsiveness was evaluated by pre-post paired-samples t-test and standardized response mean based on the patients’ health status changes following 6-month period. Results Cronbach’s α of the SF-36v2 physical and mental summary components were 0.80 and 0.86 (eight scales range 0.73–0.92) and the QOL-DAv2.0 was 0.96 (four scales range: 0.80–0.93). ICC of the SF-36v2 two components were 0.86 and 0.85 (eight scales range: 0.72–0.87) and the QOL-DAv2.0 was 0.94 (four scales range: 0.88–0.92). Convergent validity was lower between the two instruments (γ <0.70) while discriminant validity was acceptable within each instrument. Sensitivity was satisfied in self-evaluated health status (both instruments) and average daily methadone dose (SF-36v2 physical functioning and vitality scales; QOL-DAv2.0 except psychology scale). Responsiveness was acceptable in the improved health status change (SF-36v2 except vitality scale; QOL-DAv2.0 except psychology and symptoms scales) and deteriorated health status change (SF-36v2 except vitality, social functioning and mental health scales; QOL-DAv2.0 except society scale). Conclusions The SF-36v2 and the QOL-DAv2.0 are valid tools and can be used independently or complementary according to different emphases of health-related quality of life evaluation in patients with MMT. PMID:24278188
Chapman, Kent; Favaloro, Emmanuel J
2018-05-01
The Multiplate is a popular instrument that measures platelet function using whole blood. Potentially considered a point of care instrument, it is also used by hemostasis laboratories. The instrument is usually utilized to assess antiplatelet medication or as a screen of platelet function. According to the manufacturer, testing should be performed within 0.5-3 hours of blood collection, and preferably using manufacturer provided hirudin tubes. We report time-associated reduction in platelet aggregation using the Multiplate and hirudin blood collection tubes, for all the major employed agonists. Blood for Multiplate analysis was collected into manufacturer supplied hirudin tubes, and 21 consecutive samples assessed using manufacturer supplied agonists (ADP, arachidonic acid, TRAP, collagen and ristocetin), at several time-points post-sample collection within the recommended test time period. Blood was also collected into EDTA as a reference method for platelet counts, with samples collected into sodium citrate and hirudin used for comparative counts. All platelet agonists showed a diminution of response with time. Depending on the agonist, the reduction caused 5-20% and 22-47% of responses initially in the normal reference range to fall below the reference range at 120min and 180min, respectively. Considering any agonist, 35% and 67% of initially "normal" responses became 'abnormal' at 120 min and 180 min, respectively. Platelet counts showed generally minimal changes in EDTA blood, but were markedly reduced over time in both citrate and hirudin blood, with up to 40% and 60% reduction, respectively, at 240 min. The presence of platelet clumping (micro-aggregate formation) was also observed in a time dependent manner, especially for hirudin. In conclusion, considering any platelet agonist, around two-thirds of samples can, within the recommended 0.5-3 hour testing window post-blood collection, yield a reduction in platelet aggregation that may lead to a change in interpretation (i.e., normal to reduced). Thus, the stability of Multiplate testing can more realistically be considered as being between 30-120 min of blood collection for samples collected into hirudin.
Genetics/Genomics Research in the Central Region
,
2006-01-01
Genetics-based research within the Biological Resources Discipline (BRD) Science Centers in the Central Region incorporates many aspects of the field of genetics. Research activities range from documenting patterns of genetic variation in order to investigate relationships among species, populations and individuals to investigating the structure, function and expression of genes and their response to environmental stressors. Research in the broad areas of genetics requires multidisciplinary expertise and specialized equipment and instrumentation. Brief summaries of the capabilities of the five BRD Centers are given below.
Observation of arterial blood pressure of the primate
NASA Technical Reports Server (NTRS)
Meehan, J. P.; Henry, J. P.
1973-01-01
The developments are reported in physiological instrumentation, surgical procedures, measurement and data analysis techniques, and the definition of flight experiments to determine the effects of prolonged weightlessness on the cardiovascular system of subhuman primates. The development of an implantable telemetric data acquisition system is discussed along with cardiovascular research applications in renal hemodynamics. It is concluded that the implant technique permits a valid interpretation, free of emotional response, for the manipulated variable on physiological functions. It also allows a better definition of normal physiological baseline conditions.
Cost efficient command management
NASA Technical Reports Server (NTRS)
Brandt, Theresa; Murphy, C. W.; Kuntz, Jon; Barlett, Tom
1996-01-01
The design and implementation of a command management system (CMS) for a NASA control center, is described. The technology innovations implemented in the CMS provide the infrastructure required for operations cost reduction and future development cost reduction through increased operational efficiency and reuse in future missions. The command management design facilitates error-free operations which enables the automation of the routine control center functions and allows for the distribution of scheduling responsibility to the instrument teams. The reusable system was developed using object oriented methodologies.
Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, Turgut; Yodh, Arjun G.
2013-01-01
Diffuse correlation spectroscopy (DCS) uses the temporal fluctuations of near-infrared (NIR) light to measure cerebral blood flow (CBF) non-invasively. Here, we provide a brief history of DCS applications in brain with an emphasis on the underlying physical ideas, common instrumentation and validation. Then we describe recent clinical research that employs DCS-measured CBF as a biomarker of patient well-being, and as an indicator of hemodynamic and metabolic response to functional stimuli. PMID:23770408
Potyrailo, Radislav A
2017-08-29
For detection of gases and vapors in complex backgrounds, "classic" analytical instruments are an unavoidable alternative to existing sensors. Recently a new generation of sensors, known as multivariable sensors, emerged with a fundamentally different perspective for sensing to eliminate limitations of existing sensors. In multivariable sensors, a sensing material is designed to have diverse responses to different gases and vapors and is coupled to a multivariable transducer that provides independent outputs to recognize these diverse responses. Data analytics tools provide rejection of interferences and multi-analyte quantitation. This review critically analyses advances of multivariable sensors based on ligand-functionalized metal nanoparticles also known as monolayer-protected nanoparticles (MPNs). These MPN sensing materials distinctively stand out from other sensing materials for multivariable sensors due to their diversity of gas- and vapor-response mechanisms as provided by organic and biological ligands, applicability of these sensing materials for broad classes of gas-phase compounds such as condensable vapors and non-condensable gases, and for several principles of signal transduction in multivariable sensors that result in non-resonant and resonant electrical sensors as well as material- and structure-based photonic sensors. Such features should allow MPN multivariable sensors to be an attractive high value addition to existing analytical instrumentation.
An item response curves analysis of the Force Concept Inventory
NASA Astrophysics Data System (ADS)
Morris, Gary A.; Harshman, Nathan; Branum-Martin, Lee; Mazur, Eric; Mzoughi, Taha; Baker, Stephen D.
2012-09-01
Several years ago, we introduced the idea of item response curves (IRC), a simplistic form of item response theory (IRT), to the physics education research community as a way to examine item performance on diagnostic instruments such as the Force Concept Inventory (FCI). We noted that a full-blown analysis using IRT would be a next logical step, which several authors have since taken. In this paper, we show that our simple approach not only yields similar conclusions in the analysis of the performance of items on the FCI to the more sophisticated and complex IRT analyses but also permits additional insights by characterizing both the correct and incorrect answer choices. Our IRC approach can be applied to a variety of multiple-choice assessments but, as applied to a carefully designed instrument such as the FCI, allows us to probe student understanding as a function of ability level through an examination of each answer choice. We imagine that physics teachers could use IRC analysis to identify prominent misconceptions and tailor their instruction to combat those misconceptions, fulfilling the FCI authors' original intentions for its use. Furthermore, the IRC analysis can assist test designers to improve their assessments by identifying nonfunctioning distractors that can be replaced with distractors attractive to students at various ability levels.
Hernaus, Dennis; Casales Santa, Marta Ma; Offermann, Jan Stefan; Van Amelsvoort, Thérèse
2017-04-01
Experimental animal work has demonstrated that dopamine and noradrenaline play an essential role in modulating prefrontal cortex-mediated networks underlying working memory performance. Studies of functional connectivity have been instrumental in extending such notions to humans but, so far, have almost exclusively focussed on pharmacological agents with a predominant dopaminergic mechanism of action. Here, we investigate the effect of a single dose of atomoxetine 60mg, a noradrenaline transporter inhibitor, on working memory performance and associated functional connectivity during an n-back task in 19 healthy male volunteers. Atomoxetine increased functional connectivity between right anterior insula and dorsolateral prefrontal cortex, precentral gyrus, posterior parietal cortex and precuneus during the high-working memory load condition of the n-back task. Increased atomoxetine-induced insula-dorsolateral prefrontal cortex functional connectivity during this condition correlated with decreased reaction time variability and was furthermore predicted by working memory capacity. These results show for the first time that noradrenaline transporter blockade-induced increases in cortical catecholamines accentuate fronto-parietal working memory-related network integrity. The observation of significant inter-subject variability in response to atomoxetine has implications for inverted-U frameworks of dopamine and noradrenaline function, which could be useful to predict drug effects in clinical disorders with variable treatment response. Copyright © 2017 Elsevier B.V. and ECNP. All rights reserved.
NASA Astrophysics Data System (ADS)
Medvedev, Andrei V.; Kainerstorfer, Jana M.; Borisov, Sergey V.; Vanmeter, John
2011-01-01
Near-infrared spectroscopy (NIRS) is a developing technology for low-cost noninvasive functional brain imaging. With multichannel optical instruments, it becomes possible to measure not only local changes in hemoglobin concentrations but also temporal correlations of those changes in different brain regions which gives an optical analog of functional connectivity traditionally measured by fMRI. We recorded hemodynamic activity during the Go-NoGo task from 11 right-handed subjects with probes placed bilaterally over prefrontal areas. Subjects were detecting animals as targets in natural scenes pressing a mouse button. Data were low-pass filtered <1 Hz and cardiac/respiration/superficial layers artifacts were removed using Independent Component Analysis. Fisher's transformed correlations of poststimulus responses (30 s) were averaged over groups of channels unilaterally in each hemisphere (intrahemispheric connectivity) and the corresponding channels between hemispheres (interhemispheric connectivity). The hemodynamic response showed task-related activation (an increase/decrease in oxygenated/deoxygenated hemoglobin, respectively) greater in the right versus left hemisphere. Intra- and interhemispheric functional connectivity was also significantly stronger during the task compared to baseline. Functional connectivity between the inferior and the middle frontal regions was significantly stronger in the right hemisphere. Our results demonstrate that optical methods can be used to detect transient changes in functional connectivity during rapid cognitive processes.
Hicks, Kathryn
2014-09-01
This article examines the influence of emotional and instrumental support on women's immune function, a biomarker of stress, in the city of El Alto, Bolivia. It tests the prediction that instrumental support is protective of immune function for women living in this marginal environment. Qualitative and quantitative ethnographic methods were employed to assess perceived emotional and instrumental support and common sources of support; multiple linear regression analysis was used to model the relationship between social support and antibodies to the Epstein-Barr virus. These analyses provided no evidence that instrumental social support is related to women's health, but there is some evidence that emotional support from compadres helps protect immune function. © 2014 by the American Anthropological Association.
Evaluation Methods and Procedures In a Therapeutic Nursery Program.
ERIC Educational Resources Information Center
Barker, William F.
Four areas of evaluation will be briefly discussed: 1) those areas of functioning which should be assessed, 2) instruments which were used in each area, 3) knowledge of instruments, 4) preliminary results for each instrument. The areas related to the preschool child which should be evaluated consist of: 1) the child's cognitive functioning, 2) the…
Herlea-Pana, Oana; Yao, Longbiao; Heuser-Baker, Janet; Wang, Qiongxin; Wang, Qilong; Georgescu, Constantin; Zou, Ming-Hui; Barlic-Dicen, Jana
2015-05-01
Atherosclerosis manifests itself as arterial plaques, which lead to heart attacks or stroke. Treatments supporting plaque regression are therefore aggressively pursued. Studies conducted in models in which hypercholesterolaemia is reversible, such as the Reversa mouse model we have employed in the current studies, will be instrumental for the development of such interventions. Using this model, we have shown that advanced atherosclerosis regression occurs when lipid lowering is used in combination with bone-marrow endothelial progenitor cell (EPC) treatment. However, it remains unclear how EPCs home to regressing plaques and how they augment atherosclerosis reversal. Here we identify molecules that support functional responses of EPCs during plaque resolution. Chemokines CXCL1 and CX3CL1 were detected in the vascular wall of atheroregressing Reversa mice, and their cognate receptors CXCR2 and CX3CR1 were observed on adoptively transferred EPCs in circulation. We tested whether CXCL1-CXCR2 and CX3CL1-CX3CR1 axes regulate functional responses of EPCs during plaque reversal. We show that pharmacological inhibition of CXCR2 or CX3CR1, or genetic inactivation of these two chemokine receptors interfered with EPC-mediated advanced atherosclerosis regression. We also demonstrate that CXCR2 directs EPCs to regressing plaques while CX3CR1 controls a paracrine function(s) of these cells. CXCR2 and CX3CR1 differentially regulate EPC functional responses during atheroregression. Our study improves understanding of how chemokines and chemokine receptors regulate plaque resolution, which could determine the effectiveness of interventions reducing complications of atherosclerosis. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Herlea-Pana, Oana; Yao, Longbiao; Heuser-Baker, Janet; Wang, Qiongxin; Wang, Qilong; Georgescu, Constantin; Zou, Ming-Hui; Barlic-Dicen, Jana
2015-01-01
Aims Atherosclerosis manifests itself as arterial plaques, which lead to heart attacks or stroke. Treatments supporting plaque regression are therefore aggressively pursued. Studies conducted in models in which hypercholesterolaemia is reversible, such as the Reversa mouse model we have employed in the current studies, will be instrumental for the development of such interventions. Using this model, we have shown that advanced atherosclerosis regression occurs when lipid lowering is used in combination with bone-marrow endothelial progenitor cell (EPC) treatment. However, it remains unclear how EPCs home to regressing plaques and how they augment atherosclerosis reversal. Here we identify molecules that support functional responses of EPCs during plaque resolution. Methods and results Chemokines CXCL1 and CX3CL1 were detected in the vascular wall of atheroregressing Reversa mice, and their cognate receptors CXCR2 and CX3CR1 were observed on adoptively transferred EPCs in circulation. We tested whether CXCL1–CXCR2 and CX3CL1–CX3CR1 axes regulate functional responses of EPCs during plaque reversal. We show that pharmacological inhibition of CXCR2 or CX3CR1, or genetic inactivation of these two chemokine receptors interfered with EPC-mediated advanced atherosclerosis regression. We also demonstrate that CXCR2 directs EPCs to regressing plaques while CX3CR1 controls a paracrine function(s) of these cells. Conclusion CXCR2 and CX3CR1 differentially regulate EPC functional responses during atheroregression. Our study improves understanding of how chemokines and chemokine receptors regulate plaque resolution, which could determine the effectiveness of interventions reducing complications of atherosclerosis. PMID:25765938
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.
We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The methodmore » consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.« less
Jankovic, John; Zontek, Tracy L.; Ogle, Burton R.; ...
2015-01-27
We examined the calibration records of two direct reading instruments designated as condensation particle counters in order to determine the number of times they were found to be out of tolerance at annual manufacturer's recalibration. For both instruments were found to be out of tolerance more times than within tolerance. And, it was concluded that annual calibration alone was insufficient to provide operational confidence in an instrument's response. Thus, a method based on subsequent agreement with data gathered from a newly calibrated instrument was developed to confirm operational readiness between annual calibrations, hereafter referred to as bump testing. The methodmore » consists of measuring source particles produced by a gas grille spark igniter in a gallon-size jar. Sampling from this chamber with a newly calibrated instrument to determine the calibrated response over the particle concentration range of interest serves as a reference. Agreement between this reference response and subsequent responses at later dates implies that the instrument is performing as it was at the time of calibration. Side-by-side sampling allows the level of agreement between two or more instruments to be determined. This is useful when simultaneously collected data are compared for differences, i.e., background with process aerosol concentrations. A reference set of data was obtained using the spark igniter. The generation system was found to be reproducible and suitable to form the basis of calibration verification. Finally, the bump test is simple enough to be performed periodically throughout the calibration year or prior to field monitoring.« less
Lima, Maria José Barbosa de; Portela, Margareth Crisóstomo
2010-08-01
This study presents an instrument, the health-related quality of life (HRQOL) profile for independent elderly, to measure the health-related quality of life of the functionally independent elderly assisted in the outpatient setting, based on the adaptation of four validated scales: Short-Form Health Survey (SF-36), Duke-UNC Health Profile (DUHP), Sickness Impact Profile (SIP), and Nottingham Health Profile (NHP). The study also evaluates the instrument's reliability based on its use by two different observers with a 15-day interval. The instrument includes five dimensions (health perception, symptoms, physical function, psychological function, and social function) and 45 items. Reliability evaluation of the QUASI instrument was based on interviews with 142 elderly outpatients in the city of Rio de Janeiro, Brazil. Prevalence-adjusted kappa statistic was used to assess all 45 items. Correlation was also calculated between overall scores and scores on individual dimensions. In the reliability evaluation, 39 of the 45 items showed prevalence-adjusted kappa greater than 0.60.
Calibration techniques for a fast duo-spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, J.T.; Den Hartog, D.J.
1996-06-01
The authors have completed the upgrade and calibration of the Ion Dynamics Spectrometer (IDS), a high-speed Doppler duo-spectrometer which measures ion flow and temperature in the MST Reversed-field Pinch. This paper describes an in situ calibration of the diagnostic`s phase and frequency response. A single clock was employed to generate both a digital test signal and a digitizer trigger thus avoiding frequency drift and providing a highly resolved measurement over the system bandwidth. Additionally, they review the measurement of the spectrometer instrument function and absolute intensity response. This calibration and subsequent performance demonstrate the IDS to be one of themore » fastest, highest throughput diagnostics of its kind. Typical measurements are presented.« less
Voltage controlled current source
Casne, Gregory M.
1992-01-01
A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.
Measurement of workplace empowerment across caregivers.
Caspar, Sienna; O'Rourke, Norm
2011-01-01
Culture change models (CCM) developed to improve the provision of individualized care in long-term care (LTC) facilities often include initiatives that are thought to empower care staff. Therefore, the ability to measure empowerment accurately across all levels of care staff is necessary. The objective of this study was to examine the structure of responses by registered nurses (RNs), licensed practical nurses (LPNs), and care aides to 3 instruments measuring workplace empowerment: the Conditions of Work Effectiveness Questionnaire, Job Activities Scale, and Organizational Relationships Scale. Despite considerable differences in education and job function, both caregiver groups appear to interpret and respond to 38 of 40 empowerment items in a similar manner. Therefore, our findings support the inclusion of all care staff when using these instruments to measure work place empowerment in LTC settings. Copyright © 2011 Mosby, Inc. All rights reserved.
Simulations as a tool for higher mass resolution spectrometer: Lessons from existing observations
NASA Astrophysics Data System (ADS)
Nicolaou, Georgios; Yamauchi, Masatoshi; Nilsson, Hans; Wieser, Martin; Fedorov, Andrei
2017-04-01
Scientific requirements of each mission are crucial for the instrument's design. Ion tracing simulations of instruments can be helpful to characterize their performance, identify their limitations and improving the design for future missions. However, simulations provide the best performance in ideal case, and the actual response is determined by many other factors. Therefore, simulations should be compared with observations when possible. Characterizing the actual response of a running instrument gives valuable lessons for the future design of test instruments with the same detection principle before spending resources to build and calibrate them. In this study we use an ion tracing simulation of the Ion Composition Analyser (ICA) on board ROSETTA, in order to characterize its response and to compare it with the observations. It turned out that, due to the complicated unexpected response of the running instrument, the heavy cometary ions and molecules are sometimes difficult to be resolved. However, preliminary simulation of a slightly modified design predicts much higher mass resolution. Even after considering the complicated unexpected response, we safely expect that the modified design can resolve most abundant heavy atomic ions (e.g., O^+) and molecular ions (e.g., N_2+ and O_2^+). We show the simulation results for both designs and ICA data.
Convective response of a wall-mounted hot-film sensor in a shock tube
NASA Technical Reports Server (NTRS)
Roberts, A. Sidney, Jr.; Ortgies, Kelly R.; Gartenberg, Ehud; Carraway, Debra L.
1991-01-01
Shock tube experiments were performed in order to determine the response of a single hot-film element of a sensor array to transiently induced flow behind weak normal shock waves. The experiments attempt to isolate the response due only to the change in convective heat transfer at the hot-film surface mounted on the wall of the shock tube. The experiments are described, the results being correlated with transient boundary layer theory and compared with an independent set of experimental results. One of the findings indicates that the change in the air properties (temperature and pressure) precedes the air mass transport, causing an ambiguity in the sensor response to the development of the velocity boundary layer. Also, a transient, local heat transfer coefficient is formulated to be used as a forcing function in an hot-film instrument model and simulation which remains under investigation.
Noise reduction in functional near-infrared spectroscopy signals by independent component analysis
NASA Astrophysics Data System (ADS)
Santosa, Hendrik; Jiyoun Hong, Melissa; Kim, Sung-Phil; Hong, Keum-Shik
2013-07-01
Functional near-infrared spectroscopy (fNIRS) is used to detect concentration changes of oxy-hemoglobin and deoxy-hemoglobin in the human brain. The main difficulty entailed in the analysis of fNIRS signals is the fact that the hemodynamic response to a specific neuronal activation is contaminated by physiological and instrument noises, motion artifacts, and other interferences. This paper proposes independent component analysis (ICA) as a means of identifying the original hemodynamic response in the presence of noises. The original hemodynamic response was reconstructed using the primary independent component (IC) and other, less-weighting-coefficient ICs. In order to generate experimental brain stimuli, arithmetic tasks were administered to eight volunteer subjects. The t-value of the reconstructed hemodynamic response was improved by using the ICs found in the measured data. The best t-value out of 16 low-pass-filtered signals was 37, and that of the reconstructed one was 51. Also, the average t-value of the eight subjects' reconstructed signals was 40, whereas that of all of their low-pass-filtered signals was only 20. Overall, the results showed the applicability of the ICA-based method to noise-contamination reduction in brain mapping.
In-flight edge response measurements for high-spatial-resolution remote sensing systems
NASA Astrophysics Data System (ADS)
Blonski, Slawomir; Pagnutti, Mary A.; Ryan, Robert; Zanoni, Vickie
2002-09-01
In-flight measurements of spatial resolution were conducted as part of the NASA Scientific Data Purchase Verification and Validation process. Characterization included remote sensing image products with ground sample distance of 1 meter or less, such as those acquired with the panchromatic imager onboard the IKONOS satellite and the airborne ADAR System 5500 multispectral instrument. Final image products were used to evaluate the effects of both the image acquisition system and image post-processing. Spatial resolution was characterized by full width at half maximum of an edge-response-derived line spread function. The edge responses were analyzed using the tilted-edge technique that overcomes the spatial sampling limitations of the digital imaging systems. As an enhancement to existing algorithms, the slope of the edge response and the orientation of the edge target were determined by a single computational process. Adjacent black and white square panels, either painted on a flat surface or deployed as tarps, formed the ground-based edge targets used in the tests. Orientation of the deployable tarps was optimized beforehand, based on simulations of the imaging system. The effects of such factors as acquisition geometry, temporal variability, Modulation Transfer Function compensation, and ground sample distance on spatial resolution were investigated.
Instrument performance and simulation verification of the POLAR detector
NASA Astrophysics Data System (ADS)
Kole, M.; Li, Z. H.; Produit, N.; Tymieniecka, T.; Zhang, J.; Zwolinska, A.; Bao, T. W.; Bernasconi, T.; Cadoux, F.; Feng, M. Z.; Gauvin, N.; Hajdas, W.; Kong, S. W.; Li, H. C.; Li, L.; Liu, X.; Marcinkowski, R.; Orsi, S.; Pohl, M.; Rybka, D.; Sun, J. C.; Song, L. M.; Szabelski, J.; Wang, R. J.; Wang, Y. H.; Wen, X.; Wu, B. B.; Wu, X.; Xiao, H. L.; Xiong, S. L.; Zhang, L.; Zhang, L. Y.; Zhang, S. N.; Zhang, X. F.; Zhang, Y. J.; Zhao, Y.
2017-11-01
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
Lee, Andy C H; Feger, Mark A; Singla, Anuj; Abel, Mark F
2016-11-15
Systemic review and meta-analysis. To analyze the effect of spinal fusion and instrumentation for adolescent idiopathic scoliosis (AIS) on absolute pulmonary function test (PFTs). Pulmonary function is correlated with severity of deformity in AIS patients and studies that have analyzed the effect of spinal fusion and instrumentation on PFTs for AIS have reported inconsistent results. There is a need to analyze the effect of spinal fusion on PFTs with stratification by surgical approach. Our analysis included 22 studies. Cohen's d effect sizes were calculated for absolute PFT outcome measures with 95% confidence intervals (CI). Meta-analyses were performed at each postoperative time frame for six homogeneous surgical approaches: (i) combined anterior release and posterior fusion with instrumentation; (ii) combined video assisted anterior release and posterior fusion with instrumentation without thoracoplasty; (iii) posterior fusion with instrumentation without thoracoplasty; (iv) anterior fusion with instrumentation and without thoracoplasty; (v) video assisted anterior fusion with instrumentation without thoracoplasty; and (vi) any scoliosis surgery with additional thoracoplasty. Anterior spinal fusion with instrumentation, any scoliosis surgery with concomitant thoracoplasty, or video-assisted anterior fusion with instrumentation for AIS had similar absolute PFTs at their 2 year postoperative follow up compared with their preoperative PFTs (effect sizes ranging from -0.2-0.2 with all CI crossing "0"). Posterior spinal fusion with instrumentation (with or without an anterior release) demonstrated small to moderate increases in PFTs 2 years postoperatively (effect sizes ranging from 0.35-0.65 with all CI not crossing "0"). Anterior fusion with instrumentation, regardless of the approach, and any scoliosis surgery with concomitant thoracoplasty do not lead to significant change in pulmonary functions 2 year after surgery. Posterior spinal fusion with instrumentation (with or without an anterior release) resulted in small to moderate increases in PFTs. N/A.
NASA Astrophysics Data System (ADS)
Moro, Giovanni; Zannoni, Daniele; Dreossi, Giuliano; Stenni, Barbara
2017-04-01
The objective of this work is the development, standardization and creation of a method to carry out continuous measurement of oxygen and hydrogen isotopic composition of the atmospheric water vapor using a wavelength-scanned cavity ring down spectroscopy (WS-CRDS) instrument produced by Picarro, L1102-i model. Some technical improvements of the standard instrument configuration have been made to create three different inlet gas lines: a "standard" line, a calibration line and a line connected with the external sampler. The calibration line is composed of a syringe-pump that continuously injects standard water into a steel tee heated at the temperature of 170°C and flushed with dry nitrogen gas. In this way, instantaneous and complete vaporization of the standard water takes place. The resulting steam is characterized by a well-defined composition in δD e δ18O values. To allow comparison with other international data, we have characterized the individual instrumental response to variation of the isotopic composition of the water vapor. Several humidity-isotope response functions (6000-26000 ppmv) have been estimated with three different internal standards (0.35‰ -8.75‰ -29.11‰ and -40.28‰ for δ18O; 2.31‰ -58.91‰ -222.19‰ and -317.78‰ for δD). Moreover, we have measured the instrumental drift at regular time intervals to apply the opportune corrections to instrument data. The setup has been tested using a 3.5 day continuous measurements carried out with the Picarro sampling the water vapor outside our campus in Venice and parallel sampling using the classical cryogenic trapping procedure, obtaining excellent results. Furthermore, our analysis technique has given good results for the standards with values which are similar to those obtained with the isotope ratio mass spectrometry (IRMS) technique.
Koehorst, Marije L S; van Trijffel, Emiel; Lindeboom, Robert
2014-08-01
Clinical measurement, longitudinal. To assess the test-retest reliability, construct validity, and responsiveness of the Patient-Specific Functional Scale (PSFS) in patients with a primary shoulder complaint. Health measurement outcomes have become increasingly important for evaluating treatment. Patient-specific questionnaires are useful tools for determining treatment goals and evaluating treatment in individual patients. These questionnaires have not yet been validated in patients with nonspecific shoulder pain. Patients completed the PSFS, the numeric pain rating scale, and the Shoulder Pain and Disability Index at baseline, and after 1 week and 4 to 6 weeks. Test-retest reliability was determined using intraclass correlation coefficients. To assess convergent validity, change scores of the PSFS were correlated with the numeric pain rating scale and Shoulder Pain and Disability Index change scores. Responsiveness was assessed by calculating the area under the curve, the minimal clinically important change, and minimal detectable change, using the global rating of change as an external criterion. Fifty patients (37 men; mean age, 47.7 years) participated in the study. Reliability was high (intraclass correlation coefficient = 0.87; 95% confidence interval [CI]: 0.72, 0.94). The correlations between the change scores of the PSFS and those of the Shoulder Pain and Disability Index and numeric pain rating scale were 0.45 (95% CI: 0.17, 0.80) and 0.55 (95% CI: 0.29, 0.73), respectively. The area under the curve for the PSFS was 0.67 (95% CI: 0.51, 0.83). The minimal detectable change and minimal clinically important change were 0.97 and 1.29 points, respectively. These results suggest that the PSFS is a reliable, valid, and responsive instrument that can be used as an evaluative instrument in patients with a primary shoulder complaint.
Ventura, Joseph; Reise, Steven P; Keefe, Richard S E; Baade, Lyle E; Gold, James M; Green, Michael F; Kern, Robert S; Mesholam-Gately, Raquelle; Nuechterlein, Keith H; Seidman, Larry J; Bilder, Robert M
2010-08-01
Practical, reliable "real world" measures of cognition are needed to supplement neurocognitive performance data to evaluate possible efficacy of new drugs targeting cognitive deficits associated with schizophrenia. Because interview-based measures of cognition offer one possible approach, data from the MATRICS initiative (n=176) were used to examine the psychometric properties of the Schizophrenia Cognition Rating Scale (SCoRS) and the Clinical Global Impression of Cognition in Schizophrenia (CGI-CogS). We used classical test theory methods and item response theory to derive the 10-item Cognitive Assessment Interview (CAI) from the SCoRS and CGI-CogS ("parent instruments"). Sources of information for CAI ratings included the patient and an informant. Validity analyses examined the relationship between the CAI and objective measures of cognitive functioning, intermediate measures of cognition, and functional outcome. The rater's score from the newly derived CAI (10 items) correlate highly (r=.87) with those from the combined set of the SCoRS and CGI-CogS (41 items). Both the patient (r=.82) and the informant (r=.95) data were highly correlated with the rater's score. The CAI was modestly correlated with objectively measured neurocognition (r=-.32), functional capacity (r=-.44), and functional outcome (r=-.32), which was comparable to the parent instruments. The CAI allows for expert judgment in evaluating a patient's cognitive functioning and was modestly correlated with neurocognitive functioning, functional capacity, and functional outcome. The CAI is a brief, repeatable, and potentially valuable tool for rating cognition in schizophrenia patients who are participating in clinical trials. Copyright 2010 Elsevier B.V. All rights reserved.
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials
2016-04-27
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials PI Maria received support to construct a physical...vapor deposition (PVD) system that combines electron beam (e- beam) evaporation, magnetron sputtering, pulsed laser ablation, and ion-assisted deposition ...The instrumentation enables clean, uniform, and rapid deposition of a wide variety of metallic, semiconducting, and ceramic thin films with
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials
2016-04-27
Hybrid Physical Vapor Deposition Instrument for Advanced Functional Multilayers and Materials PI Maria received support to construct a physical... vapor deposition (PVD) system that combines electron beam (e- beam) evaporation, magnetron sputtering, pulsed laser ablation, and ion-assisted deposition ...peer-reviewed journals: Number of Papers published in non peer-reviewed journals: Final Report: Hybrid Physical Vapor Deposition Instrument for Advanced
Electric vehicle power train instrumentation: Some constraints and considerations
NASA Technical Reports Server (NTRS)
Triner, J. E.; Hansen, I. G.
1977-01-01
The application of pulse modulation control (choppers) to dc motors creates unique instrumentation problems. In particular, the high harmonic components contained in the current waveforms require frequency response accommodations not normally considered in dc instrumentation. In addition to current sensing, accurate power measurement requires not only adequate frequency response but must also address phase errors caused by the finite bandwidths and component characteristics involved. The implications of these problems are assessed.
[Legal capacity and instruments assessing cognitive functions in patients with dementia].
Voskou, P; Papageorgiou, S; Economou, A; Douzenis, A
2017-01-01
The term "legal capacity" refers to the ability of a person to make a valid declaration of his will or to accept such a declaration. This ability constitutes the main condition for the validity of the legal transaction. The legal transaction includes issues that are adjusted by the Civil Code with which the relations of the citizens in a society are regulated. General practitioners and legal advisors, in any case of a person with cognitive impairment of various severity, should take into account that the assessment tests of the cognitive functions are not by themselves diagnostic of the dementia and they cannot be used as the only way of evaluation of the capacity of patients with cognitive impairment or possible dementia to respond to the needs of everyday life and in more complex decisions, such as the legal capacity. The existing methods for the assessment of the cognitive functions are valuable, mainly, for the detection of any cognitive impairment which may not be perceptible during the clinical evaluation of the patient and secondly for the detection of any changes in the cognitive status of the patient during its following up. The description and study of the instruments which are frequently used in the international scientific society for the assessment of the cognitive functions of the patients with mild cognitive impairment or dementia, during the evaluation of the legal capacity of these patients. The literature relevant to the existing methods assessing the cognitive functions during the evaluation of the legal capacity of patients with dementia was reviewed. The scientific database searched was Pubmed, Medline and Scopus. The key-words used were cognitive functions, dementia, instruments, legal capacity. Various instruments which assess the cognitive functions have been developed and can be grouped in 4 categories. The first one includes instruments used for the general assessment of the cognitive status. These instruments can be extensive or short and consist of subtests for the evaluation of several cognitive functions (memory, attention, perception, speech). The second category includes instruments for the specific assessment of the cognitive status, namely specific tests for one cognitive domain (for example, memory, speech flow, naming). The third category consists of methods which are based on the clinical evaluation during the interview with the patient and his familiars, giving emphasis on the frontal functions of the patient. Finally, the fourth group includes instruments which assess the executive functions of the patients. There is a great need for the development of more studies for the methods/instruments with which the cognitive functions of patients with probable dementia can be assessed during the evaluation of the legal capacity of these patients. The challenge for the scientists is to develop a clinically applicable instrument for the quick and reliable assessment of the legal capacity of people with dementia. The assessment of this ability should be done in relation with the needs, the feelings and the values of the patient.
Time-resolved laser-induced fluorescence system
NASA Astrophysics Data System (ADS)
Bautista, F. J.; De la Rosa, J.; Gallegos, F. J.
2006-02-01
Fluorescence methods are being used increasingly in the measurement of species concentrations in gases, liquids and solids. Laser induced fluorescence is spontaneous emission from atoms or molecules that have been excited by laser radiation. Here we present a time resolved fluorescence instrument that consists of a 5 μJ Nitrogen laser (337.1 nm), a sample holder, a quartz optical fiber, a spectrometer, a PMT and a PC that allows the measurement of visible fluorescence spectra (350-750 nm). Time response of the system is approximately 5 ns. The instrument has been used in the measurement of colored bond paper, antifreeze, diesel, cochineal pigment and malignant tissues. The data acquisition was achieved through computer control of a digital oscilloscope (using General Purpose Interface Bus GPIB) and the spectrometer via serial (RS232). The instrument software provides a graphic interface that lets make some data acquisition tasks like finding fluorescence spectra, and fluorescence lifetimes. The software was developed using the Lab-View 6i graphic programming package and can be easily managed in order to add more functions to it.
Experimental study of visual accommodation
NASA Technical Reports Server (NTRS)
Cornsweet, T. N.; Crane, H. D.
1972-01-01
A summary report of a research effort related to the human visual accommodation system is presented. A theoretical study of the accommodation system was made. Subsequent effort was aimed at the development of specialized instrumentation for experiments designed to lead to understanding the nature of the control system in human accommodation. The necessary instrumentation consisted primarily of: (1) an automatic optometer to measure the state of eye focus, (2) a focus stimulator device to control the apparent optical distance to any target, and (3) a two-dimensional eye tracker. The concepts and designs of the first two instruments have been published in the open literature, but this report contains the first detailed treatment of the Purkinje eye tracker developed under this program. The report also discusses an accommodation lag model to explain the ability of the eye to apparently know the polarity of focus error even though the blur on the retina is to a first-approximation an even function. The interaction of the accommodation and eye movement systems is also discussed, as is the ability to train the visual accommodation system to a surprisingly responsive condition in only a few hours of training.
Yaffe, Mark; Luo, Michael; Goyal, Nitin; Chan, Philip; Patel, Anay; Cayo, Max; Stulberg, S David
2014-09-01
The purpose of this study was to evaluate clinical, functional, and radiographic outcomes following total knee arthroplasty (TKA) performed with patient-specific instrumentation (PSI), computer-assisted surgery (CAS), and manual instruments at short-term follow-up. 122 TKAs were performed by a single surgeon: 42 with PSI, 38 with CAS, and 40 with manual instrumentation. Preoperative, 1-month, and 6-month clinical and functional outcomes were measured using the Knee Society scoring system (knee score, function score, range of motion, and pain score). Improvements in clinical and functional outcomes from the preoperative to postoperative period were analyzed. Preoperative and postoperative radiographs were measured to evaluate limb and component alignment. Preoperative, 1-month postoperative, and 6-month postoperative knee scores, function scores, range of motion, and pain scores were highest in the PSI group compared to CAS and manual instrumentation. At 6-month follow-up, PSI TKA was associated with a statistically significant improvement in functional score when compared to manual TKA. Otherwise, there were no statistically significant differences in improvements among PSI, CAS, and manual TKA groups. The higher preoperative scores in the PSI group limits the ability to draw definitive conclusions from the raw postoperative scores, but analyzing the changes in scores revealed that PSI was associated with a statistically significant improvement in Knee Society Functional score at 6-month post-TKA as compared to CAS or manual TKA. This may be attributable to improvements in component rotation and positioning, improved component size accuracy, or other factors that are not discernible on plain radiograph.
Thrailkill, Eric A.; Bouton, Mark E.
2015-01-01
Instrumental behavior often consists of sequences or chains of responses that minimally include procurement behaviors that enable subsequent consumption behaviors. In such chains, behavioral units are linked by access to one another and eventually to a primary reinforcer, such as food or a drug. The present experiments examined the effects of extinguishing procurement responding on consumption responding after training of a discriminated heterogeneous instrumental chain. Rats learned to make a procurement response (e.g., pressing a lever) in the presence of a distinctive discriminative stimulus; making that response led to the presentation of a second discriminative stimulus that set the occasion for a consumption response (e.g., pulling a chain), which then produced a food-pellet reinforcer. Experiment 1 showed that extinction of either the full procurement-consumption chain or procurement alone weakened the consumption response tested in isolation. Experiment 2 replicated the procurement extinction effect and further demonstrated that the opportunity to make the procurement response, as opposed to simple exposure to the procurement stimulus alone, was required. In Experiment 3, rats learned 2 distinct discriminated heterogeneous chains; extinction of 1 procurement response specifically weakened the consumption response that had been associated with it. The results suggest that learning to inhibit the procurement response may produce extinction of consumption responding through mediated extinction. The experiments suggest the importance of an associative analysis of instrumental behavior chains. PMID:25915751
Claesson, Margareta; Armitage, W John; Byström, Berit; Montan, Per; Samolov, Branka; Stenvi, Ulf; Lundström, Mats
2017-09-01
Catquest-9SF is a 9-item visual disability questionnaire developed for evaluating patient-reported outcome measures after cataract surgery. The aim of this study was to use Rasch analysis to determine the responsiveness of Catquest-9SF for corneal transplant patients. Patients who underwent corneal transplantation primarily to improve vision were included. One group (n = 199) completed the Catquest-9SF questionnaire before corneal transplantation and a second independent group (n = 199) completed the questionnaire 2 years after surgery. All patients were recorded in the Swedish Cornea Registry, which provided clinical and demographic data for the study. Winsteps software v.3.91.0 (Winsteps.com, Beaverton, OR) was used to assess the fit of the Catquest-9SF data to the Rasch model. Rasch analysis showed that Catquest-9SF applied to corneal transplant patients was unidimensional (infit range, 0.73-1.32; outfit range, 0.81-1.35), and therefore, measured a single underlying construct (visual disability). The Rasch model explained 68.5% of raw variance. The response categories of the 9-item questionnaire were ordered, and the category thresholds were well defined. Item difficulty matched the level of patients' ability (0.36 logit difference between the means). Precision in terms of person separation (3.09) and person reliability (0.91) was good. Differential item functioning was notable for only 1 item (satisfaction with vision), which had a differential item functioning contrast of 1.08 logit. Rasch analysis showed that Catquest-9SF is a valid instrument for measuring visual disability in patients who have undergone corneal transplantation primarily to improve vision.
Combining item response theory with multiple imputation to equate health assessment questionnaires.
Gu, Chenyang; Gutman, Roee
2017-09-01
The assessment of patients' functional status across the continuum of care requires a common patient assessment tool. However, assessment tools that are used in various health care settings differ and cannot be easily contrasted. For example, the Functional Independence Measure (FIM) is used to evaluate the functional status of patients who stay in inpatient rehabilitation facilities, the Minimum Data Set (MDS) is collected for all patients who stay in skilled nursing facilities, and the Outcome and Assessment Information Set (OASIS) is collected if they choose home health care provided by home health agencies. All three instruments or questionnaires include functional status items, but the specific items, rating scales, and instructions for scoring different activities vary between the different settings. We consider equating different health assessment questionnaires as a missing data problem, and propose a variant of predictive mean matching method that relies on Item Response Theory (IRT) models to impute unmeasured item responses. Using real data sets, we simulated missing measurements and compared our proposed approach to existing methods for missing data imputation. We show that, for all of the estimands considered, and in most of the experimental conditions that were examined, the proposed approach provides valid inferences, and generally has better coverages, relatively smaller biases, and shorter interval estimates. The proposed method is further illustrated using a real data set. © 2016, The International Biometric Society.
Wang, Zonghua; Zhou, Juan; Luo, Xingli; Xu, Yan; She, Xi; Chen, Ling; Yin, Honghua; Wang, Xianyuan
2015-01-01
The impact of strabismus on visual function, self-image, self-esteem, and social interactions decrease health-related quality of life (HRQoL).The purpose of this study was to evaluate and refine the adult strabismus quality of life questionnaire (AS-20) by using Rasch analysis among Chinese adult patients with strabismus. We evaluated the fitness of the AS-20 with Rasch model in Chinese population by assessing unidimensionality, infit and outfit, person and item separation index and reliability, response ordering, targeting and differential item functioning (DIF). The overall AS-20 did not demonstrate unidimensional; however, it was achieved separately in the two Rasch-revised subscales: the psychosocial subscale (11 items) and the function subscale (9 items). The features of good targeting, optimal item infit and outfit, and no notable local dependence were found for each of the subscales. The rating scale was appropriate for the psychosocial subscale but a reduction to four response categories was required for the function subscale. No significant DIF were revealed for any demographic and clinical factors (e.g., age, gender, and strabismus types). The AS-20 was demonstrated by Rasch analysis to be a rigorous instrument for measuring health-related quality of life in Chinese strabismus patents if some revisions were made regarding the subscale construct and response options.
Dalal, Anand A; Nelson, Lauren; Gilligan, Theresa; McLeod, Lori; Lewis, Sandy; DeMuro-Mercon, Carla
2011-01-01
The goal of this study was to provide recommended steps to assess measurement comparability using a crossover study design and to demonstrate these steps using a short patient-reported outcome (PRO) instrument as an example. The example PRO instrument was administered via paper, Web, interactive voice response system, and interview; a randomized crossover design was used to gather data across the multiple administration types. Participants completed the PRO instrument, demographic and health questions, and a short preference questionnaire. Evaluation included comparisons of the item-level responses and agreement, comparison of mean scale scores, score classifications, and questions designed to collect usability and administration preference. Here the authors provide a four-step evaluation guide to evaluate measurement comparability and illustrate these steps using a case-finding tool. In the example, item-level kappa statistics between the paper and the alternate versions ranged from good to excellent, intraclass correlation coefficient for mean scores were above 0.70, and the rate of disagreement ranged from 2% to 14%. In addition, although participants had an administration preference, they reported few difficulties with the versions they were assigned. The steps described in this article provide a guide for evaluating whether to combine scores across administration versions to simplify analyses and interpretation under a crossover design. The guide recommends the investigation of item-level responses, summary scores, and participant usability/preference when comparing versions, with each step providing unique information to support comprehensive evaluation and informed decisions regarding whether to combine data. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Developing and testing the CHORDS: Characteristics of Responsible Drinking Survey.
Barry, Adam E; Goodson, Patricia
2011-01-01
Report on the development and psychometric testing of a theoretically and evidence-grounded instrument, the Characteristics of Responsible Drinking Survey (CHORDS). Instrument subjected to four phases of pretesting (cognitive validity, cognitive and motivational qualities, pilot test, and item evaluation) and a final posttest implementation. Large public university in Texas. Randomly selected convenience sample (n = 729) of currently enrolled students. This 78-item questionnaire measures individuals' responsible drinking beliefs, motivations, intentions, and behaviors. Cronbach α, split-half reliability, principal components analysis and Spearman ρ were conducted to investigate reliability, stability, and validity. Measures in the CHORDS exhibited high internal consistency reliability and strong correlations of split-half reliability. Factor analyses indicated five distinct scales were present, as proposed in the theoretical model. Subscale composite scores also exhibited a correlation to alcohol consumption behaviors, indicating concurrent validity. The CHORDS represents the first instrument specifically designed to assess responsible drinking beliefs and behaviors. It was found to elicit valid and reliable data among a college student sample. This instrument holds much promise for practitioners who desire to empirically investigate dimensions of responsible drinking.
ERIC Educational Resources Information Center
Floyd, Randy G.; Phaneuf, Robin L.; Wilczynski, Susan M.
2005-01-01
Indirect assessment instruments used during functional behavioral assessment, such as rating scales, interviews, and self-report instruments, represent the least intrusive techniques for acquiring information about the function of problem behavior. This article provides criteria for examining the measurement properties of these instruments…
OSIRIS-REx Visible And Infrared Spectrometer - OVIRS
NASA Technical Reports Server (NTRS)
Hair, Jason
2016-01-01
Goddard Space Flight Center: Overall Instrument Responsibility; Instrument Scientist and Deputy Instrument Scientist; Management Systems Engineering; Mechanical Hardware; Harness Assemblies; SIDECAR Assembly Code; OVIRS Integration and Environmental Qualification; OVIRS Performance Testing, Calibration and Characterization.
Fayed, Nora; de Camargo, Olaf Kraus; Kerr, Elizabeth; Rosenbaum, Peter; Dubey, Ankita; Bostan, Cristina; Faulhaber, Markus; Raina, Parminder; Cieza, Alarcos
2012-12-01
Our aims were to (1) describe the conceptual basis of popular generic instruments according to World Health Organization (WHO) definitions of functioning, disability, and health (FDH), and quality of life (QOL) with health-related quality of life (HRQOL) as a subcomponent of QOL; (2) map the instruments to the International Classification of Functioning, Disability and Health (ICF); and (3) provide information on how the analyzed instruments were used in the literature. This should enable users to make valid choices about which instruments have the desired content for a specific context or purpose. Child health-based literature over a 5-year period was reviewed to find research employing health status and QOL/HRQOL instruments. WHO definitions of FDH and QOL were applied to each item of the 15 most used instruments to differentiate measures of FDH and QOL/HRQOL. The ICF was used to describe the health and health-related content (if any) in those instruments. Additional aspects of instrument use were extracted from these articles. Many instruments that were used to measure QOL/HRQOL did not reflect WHO definitions of QOL. The ICF domains within instruments were highly variable with respect to whether body functions, activities and participation, or environment were emphasized. There is inconsistency among researchers about how to measure HRQOL and QOL. Moreover, when an ICF content analysis is applied, there is variability among instruments in the health components included and emphasized. Reviewing content is important for matching instruments to their intended purpose. © The Authors. Developmental Medicine & Child Neurology © 2012 Mac Keith Press.
Patient-assessed measures of health outcome in asthma: a comparison of four approaches.
Garratt, A M; Hutchinson, A; Russell, I
2000-06-01
The study compares the psychometric properties of four different approaches to patient-assessed health outcomes in asthma, including the Asthma Quality of Life Questionnaire (AQLQ), Newcastle Asthma Symptoms Questionnaire (NASQ), SF-12 and EuroQol. The instruments were administered by means of a self-completed postal questionnaire to 394 patients recruited from general practices in the North East of England. Patients completed a follow-up questionnaire at 6 months. The levels of missing data were assessed and instrument scores compared using correlational analysis. Scores were related to self-reports of smoking behaviour, socioeconomic status and health transition. Responsiveness was assessed using standardized response means. Two hundred and thirty-five patients took part in the study giving a response rate of 59.6%. There was a relatively large amount of missing data for the individualized section of the AQLQ. Correlational analysis provided evidence of convergent validity between the specific instruments; the largest correlation was found between NASQ scores and the asthma symptoms scale of the AQLQ (r = 0.84). The NASQ was found to be the most powerful at discriminating between smokers and non-smokers. All four instruments were linearly related to self-reported asthma transition (P<0.05); the specific instruments having the strongest association. The specific instruments showed good levels of responsiveness with the NASQ producing a large SRM of 0.82. SRMs for the AQLQ were of a moderate to large size (0.32-0.77) and the SRMs for the SF-12 and EuroQol were of a small size. The two specific instruments are capable of greater levels of discrimination between groups of patients and are more responsive to changes in health than the generic SF-12 and EuroQol. The greater responsiveness of the NASQ is probably due to its focus being restricted to symptoms of asthma compared to the broader focus of the AQLQ domains. The NASQ has a strong relationship with the AQLQ and is a more practical instrument that is more acceptable to patients. However, the AQLQ does measure broader patient concerns. The SF-12 and EuroQol have greater potential to capture side-effects and have wider scope for application in economic evaluation.
Hogarth, Lee; Dickinson, Anthony; Duka, Theodora
2005-02-01
External stimuli (S+) that reliably signal that addictive drugs are available command the focus of selective attention and control instrumental action that procures the drug. According to incentive salience theory, as the contingency between the S+ and the drug is learned the magnitude of attentional orienting towards the S+ increases. By contrast, alternative theories propose that processing of the S+ becomes more efficient with training such that the measured attentional orienting response elicited by the S+ decreases. The aim of the present study was to prompt half of participants to acquire explicit knowledge of the stimulus-reinforcer contingencies arranged in training, to examine the impact of this manipulation on the magnitude of attentional orienting towards the S+. Smokers (n=32) completed an instrumental discrimination training procedure in which a set of stimuli were established as differential predictors that an instrumental response would yield tobacco-smoke reinforcement. During training, attention for the stimuli and performance of the instrumental tobacco-seeking response were measured in parallel. One group (n=16) was prompted to develop explicit knowledge of the discriminative contingencies in training whereas another group (n=16) underwent discrimination training without prompting. The prompted group reported accurate knowledge of the contingencies and showed no attentional orienting response towards the S+. By contrast, the unprompted group reported inaccurate knowledge of the contingencies and showed an attentional orienting response towards the S+. The S+ appeared to control the instrumental tobacco-seeking response in both groups equally. The results suggest that attention for drug paired S+ is associated with the process of learning about the relationship between those cues and the drug.
Development and pilot of an international survey: 'Radiation Therapists and Psychosocial Support'.
Elsner, Kelly L; Naehrig, Diana; Halkett, Georgia K B; Dhillon, Haryana M
2018-06-07
Up to one third of radiation therapy patients are reported to have unmet psychosocial needs. Radiation therapists (RTs) have daily contact with patients and can provide daily psychosocial support to reduce patient anxiety, fear and loneliness. However, RTs vary in their values, skills, training, knowledge and involvement in providing psychosocial support. The aims of this study were to: (1) develop an online survey instrument to explore RT values, skills, training and knowledge regarding patient anxiety and psychosocial support, and (2) pilot the instrument with RT professionals to assess content validity, functionality and length. An online cross-sectional survey, titled 'Radiation therapists and psychosocial support' was developed. Items included patient vignettes, embedded items from RT research, and the Professional Quality of Life Scale (ProQOL5). Four radiation oncology departments volunteered to pilot the survey; each nominated four RT staff to participate. Survey data were analysed descriptively and qualitative feedback grouped and coded to determine whether the survey needed to be refined. Thirteen of sixteen RTs completed the pilot survey and feedback form. Median time to completion was 35 mins, with 54% of respondents stating this was too long. Respondents reported content, questions and response options were relevant and appropriate. Feedback was used to: refine the survey instrument, minimise responder burden and drop out and improve functionality and quality of data collection. This pilot of the 'Radiation therapists and psychosocial support' survey instrument demonstrated content validity and usability. The main survey will be circulated to a representative sample of RTs for completion. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.
NASA Astrophysics Data System (ADS)
Tol, Paul; van Hees, Richard; van Kempen, Tim; Krijger, Matthijs; Cadot, Sidney; Aben, Ilse; Ludewig, Antje; Dingjan, Jos; Persijn, Stefan; Hoogeveen, Ruud
2016-10-01
The Tropospheric Monitoring Instrument (TROPOMI) on-board the Sentinel-5 Precursor satellite is an Earth-observing spectrometer with bands in the ultraviolet, visible, near infrared and short-wave infrared (SWIR). It provides daily global coverage of atmospheric trace gases relevant for tropospheric air quality and climate research. Three new techniques will be presented that are unique for the TROPOMI-SWIR spectrometer. The retrieval of methane and CO columns from the data of the SWIR band requires for each detector pixel an accurate instrument spectral response function (ISRF), i.e. the normalized signal as a function of wavelength. A new determination method for Earth-observing instruments has been used in the on-ground calibration, based on measurements with a SWIR optical parametric oscillator (OPO) that was scanned over the whole TROPOMI-SWIR spectral range. The calibration algorithm derives the ISRF without needing the absolute wavelength during the measurement. The same OPO has also been used to determine the two-dimensional stray-light distribution for each SWIR pixel with a dynamic range of 7 orders. This was achieved by combining measurements at several exposure times and taking saturation into account. The correction algorithm and data are designed to remove the mean stray-light distribution and a reflection that moves relative to the direct image, within the strict constraints of the available time for the L01b processing. A third new technique is an alternative calibration of the SWIR absolute radiance and irradiance using a black body at the temperature of melting silver. Unlike a standard FEL lamp, this source does not have to be calibrated itself, because the temperature is very stable and well known. Measurement methods, data analyses, correction algorithms and limitations of the new techniques will be presented.
Tribukait, Arne; Eiken, Ola
2017-11-01
An aircraft's orientation relative to the ground cannot be perceived via the sense of balance or the somatosensory system. When devoid of external visual references, the pilot must rely on instruments. A sudden unexpected instrument indication is a challenge to the pilot, who might have to question the instrument instead of responding with the controls. In this case report we analyze, from a human-factors perspective, how a limited instrument failure led to a fatal accident. During straight-ahead level flight in darkness, at 33,000 ft, the commander of a civil cargo airplane was suddenly confronted by an erroneous pitch-up indication on his primary flight display. He responded by pushing the control column forward, making a bunt maneuver with reduced/negative Gz during approximately 15 s. The pilots did not communicate rationally or cross-check instruments. Recordings of elevator and aileron positions suggest that the commander made intense efforts to correct for several extreme and erroneous roll and pitch indications. Gz displayed an increasing trend with rapid fluctuations and peaks of approximately 3 G. After 50 s the aircraft entered a turn with decreasing radius and finally hit the ground in an inverted attitude. A precipitate maneuvring response can, even if occurring in a large aircraft at high altitude, result in a seemingly inexorable course of events, ending with a crash. In the present case both pilots were probably incapacitated by acute psychological stress and spatial disorientation. Intense variations in Gz may have impaired the copilot's reading of the functioning primary flight display.Tribukait A, Eiken O. Instrument failure, stress, and spatial disorientation leading to a fatal crash with a large aircraft. Aerosp Med Hum Perform. 2017; 88(11):1043-1048.
Optoelectronic pH Meter: Further Details
NASA Technical Reports Server (NTRS)
Jeevarajan, Antony S.; Anderson, Mejody M.; Macatangay, Ariel V.
2009-01-01
A collection of documents provides further detailed information about an optoelectronic instrument that measures the pH of an aqueous cell-culture medium to within 0.1 unit in the range from 6.5 to 7.5. The instrument at an earlier stage of development was reported in Optoelectronic Instrument Monitors pH in a Culture Medium (MSC-23107), NASA Tech Briefs, Vol. 28, No. 9 (September 2004), page 4a. To recapitulate: The instrument includes a quartz cuvette through which the medium flows as it is circulated through a bioreactor. The medium contains some phenol red, which is an organic pH-indicator dye. The cuvette sits between a light source and a photodetector. [The light source in the earlier version comprised red (625 nm) and green (558 nm) light-emitting diodes (LEDs); the light source in the present version comprises a single green- (560 nm)-or-red (623 nm) LED.] The red and green are repeatedly flashed in alternation. The responses of the photodiode to the green and red are processed electronically to obtain the ratio between the amounts of green and red light transmitted through the medium. The optical absorbance of the phenol red in the green light varies as a known function of pH. Hence, the pH of the medium can be calculated from the aforesaid ratio.
Quick Assessment of Literacy in Primary Care: The Newest Vital Sign
Weiss, Barry D.; Mays, Mary Z.; Martz, William; Castro, Kelley Merriam; DeWalt, Darren A.; Pignone, Michael P.; Mockbee, Joy; Hale, Frank A.
2005-01-01
PURPOSE Current health literacy screening instruments for health care settings are either too long for routine use or available only in English. Our objective was to develop a quick and accurate screening test for limited literacy available in English and Spanish. METHODS We administered candidate items for the new instrument and also the Test of Functional Health Literacy in Adults (TOFHLA) to English-speaking and Spanish-speaking primary care patients. We measured internal consistency with Cronbach’s α and assessed criterion validity by measuring correlations with TOFHLA scores. Using TOFLHA scores <75 to define limited literacy, we plotted receiver-operating characteristics (ROC) curves and calculated likelihood ratios for cutoff scores on the new instrument. RESULTS The final instrument, the Newest Vital Sign (NVS), is a nutrition label that is accompanied by 6 questions and requires 3 minutes for administration. It is reliable (Cronbach α >0.76 in English and 0.69 in Spanish) and correlates with the TOFHLA. Area under the ROC curve is 0.88 for English and 0.72 for Spanish versions. Patients with more than 4 correct responses are unlikely to have low literacy, whereas fewer than 4 correct answers indicate the possibility of limited literacy. CONCLUSION NVS is suitable for use as a quick screening test for limited literacy in primary health care settings. PMID:16338915
Applying mixed methods to pretest the Pressure Ulcer Quality of Life (PU-QOL) instrument.
Gorecki, C; Lamping, D L; Nixon, J; Brown, J M; Cano, S
2012-04-01
Pretesting is key in the development of patient-reported outcome (PRO) instruments. We describe a mixed-methods approach based on interviews and Rasch measurement methods in the pretesting of the Pressure Ulcer Quality of Life (PU-QOL) instrument. We used cognitive interviews to pretest the PU-QOL in 35 patients with pressure ulcers with the view to identifying problematic items, followed by Rasch analysis to examine response options, appropriateness of the item series and biases due to question ordering (item fit). We then compared findings in an interactive and iterative process to identify potential strengths and weaknesses of PU-QOL items, and guide decision-making about further revisions to items and design/layout. Although cognitive interviews largely supported items, they highlighted problems with layout, response options and comprehension. Findings from the Rasch analysis identified problems with response options through reversed thresholds. The use of a mixed-methods approach in pretesting the PU-QOL instrument proved beneficial for identifying problems with scale layout, response options and framing/wording of items. Rasch measurement methods are a useful addition to standard qualitative pretesting for evaluating strengths and weaknesses of early stage PRO instruments.
A Swedish cross-cultural adaptation and validation of the Tinnitus Functional Index.
Hoff, Maria; Kähäri, Kim
2017-04-01
The Tinnitus Functional Index (TFI) is a recent self-report instrument for tinnitus with potential advantages over other existing instruments, including a demonstrated high responsiveness. The objectives of this study were to translate and cross-culturally adapt the TFI into Swedish and to investigate its validity and reliability. The development of the Swedish version (TFI-SE) followed published guidelines on cross-cultural adaptation of health questionnaires. Validity and reliability was investigated by correlating responses on the TFI-SE with other tinnitus measures [Tinnitus Handicap Inventory (THI) and visual analogue scale (VAS)] and a scale measuring anxiety and depression (HADS). Consecutively recruited tinnitus patients (n = 100) from four Swedish clinics completed the questionnaires. The mean age of the sample was 51 years (SD =17). The internal consistency of the TFI-SE was good (α = 0.95) and the test-retest reliability was high (ICC =0.93). Our results supported the eight-factor structure proposed for the original TFI, and a high correlation between the TFI-SE and the THI (r = 0.8; p < 0.01) and lower correlations between the TFI-SE and the HADS-D (r = 0.60; p < 0.01) and HADS-A (r = 0.59; p < 0.01) confirmed satisfactory convergent and discriminant validity. We found that the Swedish translation and cross-cultural adaptation of the TFI is valid and reliable for use with adult tinnitus patients.
Tuntland, Hanne; Aaslund, Mona Kristin; Langeland, Eva; Espehaug, Birgitte; Kjeken, Ingvild
2016-01-01
The Canadian Occupational Performance Measure (COPM) is an occupational therapy instrument designed to help participants identify, prioritize, and evaluate performance of important occupations. To investigate the validity, responsiveness, interpretability, and feasibility of the COPM when used by various health professions in home-dwelling older adults receiving reablement. Reablement is a new form of multidisciplinary home-based rehabilitation for older adults experiencing functional decline. The sample of 225 participants, mean age 80.8 years, who were in need of rehabilitation for various health conditions were included in the study. Data collection was conducted at baseline and at 10 weeks follow-up. The COSMIN guidelines and recommendations for evaluating methodological quality were followed. Content validity, construct validity, and feasibility were found to be adequate. Responsiveness, however, was moderate. Functional mobility was the most frequently prioritized occupational category of all. Regarding interpretability, the minimal important change was 3.0 points and 3.2 points for performance and satisfaction, respectively. The older adults reported that COPM was a useful and manageable instrument. The majority of the occupational therapists, physiotherapists, and nurses reported that they had the required expertise to conduct the COPM assessments. The results support the multidisciplinary use of the COPM in clinical practice and research in a home-dwelling, heterogeneous population of older adults. Based on the findings, 3 points are recommended as a cutoff point to distinguish between older adults who have a minimal important change in COPM performance and COPM satisfaction and those who have not.
Biomimetic approaches with smart interfaces for bone regeneration.
Sailaja, G S; Ramesh, P; Vellappally, Sajith; Anil, Sukumaran; Varma, H K
2016-11-05
A 'smart tissue interface' is a host tissue-biomaterial interface capable of triggering favourable biochemical events inspired by stimuli responsive mechanisms. In other words, biomaterial surface is instrumental in dictating the interface functionality. This review aims to investigate the fundamental and favourable requirements of a 'smart tissue interface' that can positively influence the degree of healing and promote bone tissue regeneration. A biomaterial surface when interacts synergistically with the dynamic extracellular matrix, the healing process become accelerated through development of a smart interface. The interface functionality relies equally on bound functional groups and conjugated molecules belonging to the biomaterial and the biological milieu it interacts with. The essential conditions for such a special biomimetic environment are discussed. We highlight the impending prospects of smart interfaces and trying to relate the design approaches as well as critical factors that determine species-specific functionality with special reference to bone tissue regeneration.
49 CFR 213.333 - Automated vehicle inspection systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... hours of the inspection, output reports that— (1) Provide a continuous plot, on a constant-distance axis... instrumented car having dynamic response characteristics that are representative of other equipment assigned to... instrumented car having dynamic response characteristics that are representative of other equipment assigned to...
49 CFR 213.333 - Automated vehicle inspection systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... hours of the inspection, output reports that— (1) Provide a continuous plot, on a constant-distance axis... instrumented car having dynamic response characteristics that are representative of other equipment assigned to... instrumented car having dynamic response characteristics that are representative of other equipment assigned to...
Pilot response to peripheral vision cues during instrument flying tasks.
DOT National Transportation Integrated Search
1968-02-01
In an attempt to more closely associate the visual aspects of instrument flying with that of contact flight, a study was made of human response to peripheral vision cues relating to aircraft roll attitude. Pilots, ranging from 52 to 12,000 flying hou...
Arecibo Optical Laboratory Upgrade: imaging FPI first results
NASA Astrophysics Data System (ADS)
Noto, J.; Kerr, R. B.; Migliozzi, M. A.; Tepley, C. A.; Friedman, J.; Garcia, R.; Robles, E.; Waldrop, L. S.
2006-05-01
The Optical Laboratory at the Arecibo Observatory is being upgraded to permit remote operation, to improve Fabry-Perot Interferometer (FPI) sensitivity, and to permit FPI response in the near infrared. Integration of a 2048 x 2048 Andor CCD array into the existing low-resolution Fabry Perot Interferometer is complete. Remote operation and data acquisition for this FPI is accomplished by transition from the obsolete PDP-11 data acquisition system to PC-based, internet aware control. Another upgrade stage, adding a near-infrared focal plane array to a second FPI is scheduled for the fall of this year. Configured with a spectral resolution of 0.0086 nm at 656.3 nm, the low resolution FPI sampled the geocoronal Balmer-alpha emission during three new moon periods in November and December, 2005, and January, 2006. The latter two observation campaigns were conducted using the new remote control capability. The single etalon FPI produces three orders at the CCD plane corresponding to a full field-of-view of 0.92 degrees. The FPI Hadinger ring pattern is summed annularly, and the three orders are subsequently summed, producing an instrument sensitivity that is 43 times better than the previous single channel photomultiplier detection system. Raw detector response is corrected using both linear (chip bias) and non-linear techniques (flat-field) prior to ring-summing. A frequency stabilized HeNe laser at 632.8 nm is remotely operated to establish the FPI response function. Effective exospheric temperature and line profile asymmetries are determined after decomposition of the instrument response function from the measured airglow emission. Identification and climatological characterization of non-Maxwellian H distributions, with simultaneous quantification of H+ abundance and flow in the topside ionosphere by the Arecibo incoherent scatter radar, are measurements central to our goal of improved understanding of H on H+ charge exchange escape of H.
Development of an easy-to-use Spanish Health Literacy test.
Lee, Shoou-Yih D; Bender, Deborah E; Ruiz, Rafael E; Cho, Young Ik
2006-08-01
The study was intended to develop and validate a health literacy test, termed the Short Assessment of Health Literacy for Spanish-speaking Adults (SAHLSA), for the Spanish-speaking population. The design of SAHLSA was based on the Rapid Estimate of Adult Literacy in Medicine (REALM), known as the most easily administered tool for assessing health literacy in English. In addition to the word recognition test in REALM, SAHLSA incorporates a comprehension test using multiple-choice questions designed by an expert panel. Validation of SAHLSA involved testing and comparing the tool with other health literacy instruments in a sample of 201 Spanish-speaking and 202 English-speaking subjects recruited from the Ambulatory Care Center at UNC Health Care. With only the word recognition test, REALM could not differentiate the level of health literacy in Spanish. The SAHLSA significantly improved the differentiation. Item response theory analysis was performed to calibrate the SAHLSA and reduce the instrument to 50 items. The resulting instrument, SAHLSA-50, was correlated with the Test of Functional Health Literacy in Adults, another health literacy instrument, at r=0.65. The SAHLSA-50 score was significantly and positively associated with the physical health status of Spanish-speaking subjects (p<.05), holding constant age and years of education. The instrument displayed good internal reliability (Cronbach's alpha=0.92) and test-retest reliability (Pearson's r=0.86). The new instrument, SAHLSA-50, has good reliability and validity. It could be used in the clinical or community setting to screen for low health literacy among Spanish speakers.
Analysing exoplanetary data using unsupervised machine-learning
NASA Astrophysics Data System (ADS)
Waldmann, I. P.
2012-04-01
The field of transiting extrasolar planets and especially the study of their atmospheres is one of the youngest and most dynamic subjects in current astrophysics. Permanently at the edge of technical feasibility, we are successfully discovering and characterising smaller and smaller planets. To study exoplanetary atmospheres, we typically require a 10-4 to 10-5 level of accuracy in flux. Achieving such a precision has become the central challenge to exoplanetary research and is often impeded by systematic (nongaussian) noise from either the instrument, stellar activity or both. Dedicated missions, such as Kepler, feature an a priori instrument calibration plan to the required accuracy but nonetheless remain limited by stellar systematics. More generic instruments often lack a sufficiently defined instrument response function, making it very hard to calibrate. In these cases, it becomes interesting to know how well we can calibrate the data without any additional or prior knowledge of the instrument or star. In this conference, we present a non-parametric machine-learning algorithm, based on the concept of independent component analysis, to de-convolve the systematic noise and all non-Gaussian signals from the desired astrophysical signal. Such a 'blind' signal de-mixing is commonly known as the 'Cocktail Party problem' in signal-processing. We showcase the importance and broad applicability of unsupervised machine learning in exoplanetary data analysis by discussing: 1) the removal of instrument systematics in a re-analysis of an HD189733b transmission spectrum obtained with Hubble/NICMOS; 2) the removal of time-correlated stellar noise in individual lightcurves observed by the Kepler mission.
Development of an Easy-to-Use Spanish Health Literacy Test
Lee, Shoou-Yih D; Bender, Deborah E; Ruiz, Rafael E; Cho, Young Ik
2006-01-01
Objective The study was intended to develop and validate a health literacy test, termed the Short Assessment of Health Literacy for Spanish-speaking Adults (SAHLSA), for the Spanish-speaking population. Study Design The design of SAHLSA was based on the Rapid Estimate of Adult Literacy in Medicine (REALM), known as the most easily administered tool for assessing health literacy in English. In addition to the word recognition test in REALM, SAHLSA incorporates a comprehension test using multiple-choice questions designed by an expert panel. Data Collection Validation of SAHLSA involved testing and comparing the tool with other health literacy instruments in a sample of 201 Spanish-speaking and 202 English-speaking subjects recruited from the Ambulatory Care Center at UNC Health Care. Principal Findings With only the word recognition test, REALM could not differentiate the level of health literacy in Spanish. The SAHLSA significantly improved the differentiation. Item response theory analysis was performed to calibrate the SAHLSA and reduce the instrument to 50 items. The resulting instrument, SAHLSA-50, was correlated with the Test of Functional Health Literacy in Adults, another health literacy instrument, at r = 0.65. The SAHLSA-50 score was significantly and positively associated with the physical health status of Spanish-speaking subjects (p < .05), holding constant age and years of education. The instrument displayed good internal reliability (Cronbach's α = 0.92) and test–retest reliability (Pearson's r = 0.86). Conclusions The new instrument, SAHLSA-50, has good reliability and validity. It could be used in the clinical or community setting to screen for low health literacy among Spanish speakers. PMID:16899014
Use of the moon to support on-orbit sensor calibration for climate change measurements
Stone, T.C.; Kieffer, H.H.
2006-01-01
Production of reliable climate datasets from multiple observational measurements acquired by remote sensing satellite systems available now and in the future places stringent requirements on the stability of sensors and consistency among the instruments and platforms. Detecting trends in environmental parameters measured at solar reflectance wavelengths (0.3 to 2.5 microns) requires on-orbit instrument stability at a level of 1% over a decade. This benchmark can be attained using the Moon as a radiometric reference. The lunar calibration program at the U.S. Geological Survey has an operational model to predict the lunar spectral irradiance with precision ???1%, explicitly accounting for the effects of phase, lunar librations, and the lunar surface photometric function. A system for utilization of the Moon by on-orbit instruments has been established. With multiple lunar views taken by a spacecraft instrument, sensor response characterization with sub-percent precision over several years has been achieved. Meteorological satellites in geostationary orbit (GEO) capture the Moon in operational images; applying lunar calibration to GEO visible-channel image archives has the potential to develop a climate record extending decades into the past. The USGS model and system can provide reliable transfer of calibration among instruments that have viewed the Moon as a common source. This capability will be enhanced with improvements to the USGS model absolute scale. Lunar calibration may prove essential to the critical calibration needs to cover a potential gap in observational capabilities prior to deployment of NPP/NPOESS. A key requirement is that current and future instruments observe the Moon.
ERIC Educational Resources Information Center
Rahman, Anna N.; Applebaum, Robert A.
2009-01-01
The Minimum Data Set (MDS) is a uniform instrument used in nursing homes to assess residents. In January 2008, the Centers for Medicare and Medicaid Services published a draft of a new MDS--version 3.0. This article traces the instrument's development and the design decisions that shaped it, discusses the MDS's manifest functions--data collection…
Still at the choice-point: action selection and initiation in instrumental conditioning.
Balleine, Bernard W; Ostlund, Sean B
2007-05-01
Contrary to classic stimulus-response (S-R) theory, recent evidence suggests that, in instrumental conditioning, rats encode the relationship between their actions and the specific consequences that these actions produce. It has remained unclear, however, how encoding this relationship acts to control instrumental performance. Although S-R theories were able to give a clear account of how learning translates into performance, the argument that instrumental learning constitutes the acquisition of information of the form "response R leads to outcome O" does not directly imply a particular performance rule or policy; this information can be used both to perform R and to avoid performing R. Recognition of this problem has forced the development of accounts that allow the O and stimuli that predict the O (i.e., S-O) to play a role in the initiation of specific Rs. In recent experiments, we have used a variety of behavioral procedures in an attempt to isolate the processes that contribute to instrumental performance, including outcome devaluation, reinstatement, and Pavlovian-instrumental transfer. Our results, particularly from experiments assessing outcome-selective reinstatement, suggest that both "feed-forward" (O-R) and "feed-back" (R-O) associations are critical and that although the former appear to be important to response selection, the latter-together with processes that determine outcome value-mediate response initiation. We discuss a conceptual model that integrates these processes and its neural implementation.
Operation Redwing -- Project 5. 2. In-flight participation of a B-52. Report for May-July 1956
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, F.L.
1985-04-01
The primary objective of this Project was to obtain measured-energy input and aircraft-response data on an instrumented B-52 aircraft when subjected to the thermal, blast, and gust effects of a nuclear explosion. To accomplish this, analysis was used in selecting the spatial location for the B-52, relative to a detonation, that would result in the desired aircraft inputs and responses. The B-52 was extensively instrumented with the major portion of the instrumentation devoted to measuring aircraft responses. The B-52 participated in nine shots, including one shot which the aircraft aborted just prior to time zero because of Bombing Navigation Systemmore » difficulties. The reliability of the instrumentation system was between 95% and 100% throughout the test program.« less
NASA Astrophysics Data System (ADS)
Kowalewski, M. G.; Janz, S. J.
2015-02-01
Methods of absolute radiometric calibration of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration uncertainties. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV, Total Ozone Mapping Spectrometer, Ozone Mapping Instrument, and Global Ozone Monitoring Experiment 2 using standardized procedures traceable to national standards. These sphere-based spectral responsivities agree to within the derived combined standard uncertainty of 1.87% relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary spectral radiance responsivity calibration method for BUV instruments. The combined standard uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Center’s Radiometric Calibration and Development Laboratory is shown to less than 2% at 250 nm when using a single traceable calibration standard.
[Instrument to measure adherence in hypertensive patients: contribution of Item Response Theory].
Rodrigues, Malvina Thaís Pacheco; Moreira, Thereza Maria Magalhaes; Vasconcelos, Alexandre Meira de; Andrade, Dalton Francisco de; Silva, Daniele Braz da; Barbetta, Pedro Alberto
2013-06-01
To analyze, by means of "Item Response Theory", an instrument to measure adherence to t treatment for hypertension. Analytical study with 406 hypertensive patients with associated complications seen in primary care in Fortaleza, CE, Northeastern Brazil, 2011 using "Item Response Theory". The stages were: dimensionality test, calibrating the items, processing data and creating a scale, analyzed using the gradual response model. A study of the dimensionality of the instrument was conducted by analyzing the polychoric correlation matrix and factor analysis of complete information. Multilog software was used to calibrate items and estimate the scores. Items relating to drug therapy are the most directly related to adherence while those relating to drug-free therapy need to be reworked because they have less psychometric information and low discrimination. The independence of items, the small number of levels in the scale and low explained variance in the adjustment of the models show the main weaknesses of the instrument analyzed. The "Item Response Theory" proved to be a relevant analysis technique because it evaluated respondents for adherence to treatment for hypertension, the level of difficulty of the items and their ability to discriminate between individuals with different levels of adherence, which generates a greater amount of information. The instrument analyzed is limited in measuring adherence to hypertension treatment, by analyzing the "Item Response Theory" of the item, and needs adjustment. The proper formulation of the items is important in order to accurately measure the desired latent trait.
Adding Interferometer Restoration and Upgrade: Learning by Doing with the NINE Program
NASA Astrophysics Data System (ADS)
Saby, Linnea
2017-01-01
During the summer of 2016, participants in the National and International Non-Traditional Exchange (NINE) Program were responsible for the restoration and upgrade of N2I2, an instructional interferometer located on New Mexico Tech's Socorro campus. The NINE program is a National Radio Astronomy Observatory (NRAO) initiative geared towards providing training in project management and other STEM functional areas to underrepresented groups around the world. A description of this restoration project illustrates both the experience of a NINE program participant and, more specifically, how principles of engineering and project management were applied to achieve project objectives.N2I2 was created by a joint NRAO-New Mexico Tech (NMT) team and became operational in 2004. The original instrument comprised two ten-foot dishes which recieved signals that were added using a simple power combiner, and data was interpreted using software on computers located in a nearby control room. The theory of adding interferometry was re-discovered for the design of this unique telescope. N2I2 was built using simple hardware with the intention of allowing interested community members and students from middle school to graduate school to learn about the principles of radio astronomy.Unfortunately, between 2008 and 2016 N2I2 was not used on a regular basis and fell into disrepair. NINE program director Lory Wingate accepted the responsibility of restoring the instrument as an experiential learning opportunity for the Socorro, New Mexico NINE team.During their 9 week assignment, the NINE team created a project plan, replaced and upgraded antenna hardware, developed operation and maintenance manuals, and refurbished the control room. A project plan was created for the addition of a third antenna and that plan was successfully carried out during August and September of 2016.Ultimately, functionality was successfully restored and improved, a maintenance plan was put into place, and community interest in the instrument was reignited.
The Use of Structural-Acoustic Techniques to Assess Potential Structural Damage From Sonic Booms
NASA Technical Reports Server (NTRS)
Garrelick, Joel; Martini, Kyle
1996-01-01
The potential impact of supersonic operations includes structural damage from the sonic boom overpressure. This paper describes a study of how structural-acoustic modeling and testing techniques may be used to assess the potential for such damage in the absence of actual flyovers. Procedures are described whereby transfer functions relating structural response to sonic boom signature may be obtained with a stationary acoustic source and appropriate data processing. Further, by invoking structural-acoustic reciprocity, these transfer functions may also be acquired by measuring the radiated sound from the structure under a mechanical drive. The approach is based on the fundamental assumption of linearity, both with regard to the (acoustic) propagation of the boom in the vicinity of the structure and to the structure's response. Practical issues revolve around acoustic far field and source directivity requirements. The technique was implemented on a specially fabricated test structure at Edwards AFB, CA with the support of Wyle Laboratories, Inc. Blank shots from a cannon served as our acoustic source and taps from an instrumented hammer generated the mechanical drive. Simulated response functions were constructed. Results of comparisons with corresponding measurements recorded during dedicated supersonic flyovers with F-15 aircraft are presented for a number of sensor placements.
NASA Astrophysics Data System (ADS)
Kuppers, J. D.; Gouverneur, I. M.; Rodgers, M. T.; Wenger, J.; Furlong, C.
2006-08-01
In atomic probe microscopy, micro-probes of various sizes, geometries, and materials are used to define the interface between the samples under investigation and the measuring detectors and instrumentation. Therefore, measuring resolution in atomic probe microscopy is highly dependent on the transfer function characterizing the micro-probes used. In this paper, characterization of the dynamic transfer function of specific micro-cantilever probes used in an Atomic Force Microscope (AFM) operating in the tapping mode is presented. Characterization is based on the combined application of laser Doppler vibrometry (LDV) and real-time stroboscopic optoelectronic holographic microscopy (OEHM) methodologies. LDV is used for the rapid measurement of the frequency response of the probes due to an excitation function containing multiple frequency components. Data obtained from the measured frequency response is used to identify the principal harmonics. In order to identify mode shapes corresponding to the harmonics, full-field of view OEHM is applied. This is accomplished by measurements of motion at various points on the excitation curve surrounding the identified harmonics. It is shown that the combined application of LDV and OEHM enables the high-resolution characterization of mode shapes of vibration, damping characteristics, as well as transient response of the micro-cantilever probes. Such characterization is necessary in high-resolution AFM measurements.
NASA Technical Reports Server (NTRS)
Mantus, M.; Pardo, H.
1973-01-01
Computer programming, data processing, and a correlation study that employed data collected in the first phase test were used to demonstrate that standard test procedures and equipment could be used to collect a significant number of transfer functions from tests of the Lunar Module test article LTA-11. The testing consisted of suspending the vehicle from the apex fittings of the outrigger trusses through a set of air springs to simulate the free-free state. Impulsive loadings were delivered, one at a time, at each of the landing gear's attachment points, in three mutually perpendicular directions; thus a total of 36 impulses were applied to the vehicle. Time histories of each pulse were recorded on magnetic tape along with 40 channels of strain gage response and 28 channels of accelerometer response. Since an automated data processing system was not available, oscillograph playbacks were made of all 2400 time histories as a check on the validity of the data taken. In addition, one channel of instrumentation was processed to determine its response to a set of forcing functions from a prior LTA-11 drop test. This prediction was compared with drop test results as a first measure of accuracy.
Paz, Sylvia H; Jones, Loretta; Calderón, José L; Hays, Ron D
2017-02-01
Depression and physical function are particularly important health domains for the elderly. The Geriatric Depression Scale (GDS) and the Patient-Reported Outcomes Measurement Information System (PROMIS ® ) physical function item bank are two surveys commonly used to measure these domains. It is unclear if these two instruments adequately measure these aspects of health in minority elderly. The aim of this study was to estimate the readability of the GDS and PROMIS ® physical function items and to assess their comprehensibility using a sample of African American and Latino elderly. Readability was estimated using the Flesch-Kincaid and Flesch Reading Ease (FRE) formulae for English versions, and a Spanish adaptation of the FRE formula for the Spanish versions. Comprehension of the GDS and PROMIS ® items by minority elderly was evaluated with 30 cognitive interviews. Readability estimates of a number of items in English and Spanish of the GDS and PROMIS ® physical functioning items exceed the U.S. recommended 5th-grade threshold for vulnerable populations, or were rated as 'fairly difficult', 'difficult', or 'very difficult' to read. Cognitive interviews revealed that many participants felt that more than the two (yes/no) GDS response options were needed to answer the questions. Wording of several PROMIS ® items was considered confusing, and interpreting responses was problematic because they were based on using physical aids. Problems with item wording and response options of the GDS and PROMIS ® physical function items may reduce reliability and validity of measurement when used with minority elderly.
NASA Astrophysics Data System (ADS)
Calloway, Raymond S.; Knight, Vernie H., Jr.
NASA Langley's Crash Response Data System (CRDS) which is designed to acquire aircraft structural and anthropomorphic dummy responses during the full-scale transport CID test is described. Included in the discussion are the system design approach, details on key instrumentation subsystems and operations, overall instrumentation crash performance, and data recovery results. Two autonomous high-environment digital flight instrumentation systems, DAS 1 and DAS 2, were employed to obtain research data from various strain gage, accelerometer, and tensiometric sensors installed in the B-720 test aircraft. The CRDS successfully acquired 343 out of 352 measurements of dynamic crash data.
Effectiveness of headgear in football
Withnall, C; Shewchenko, N; Wonnacott, M; Dvorak, J; Scott, D
2005-01-01
Objectives: Commercial headgear is currently being used by football players of all ages and skill levels to provide protection from heading and direct impact. The clinical and biomechanical effectiveness of the headgear in attenuating these types of impact is not well defined or understood. This study was conducted to determine whether football headgear has an effect on head impact responses. Methods: Controlled laboratory tests were conducted with a human volunteer and surrogate head/neck system. The impact attenuation of three commercial headgears during ball impact speeds of 6–30 m/s and in head to head contact with a closing speed of 2–5 m/s was quantified. The human subject, instrumented to measure linear and angular head accelerations, was exposed to low severity impacts during heading in the unprotected and protected states. High severity heading contact and head to head impacts were studied with a biofidelic surrogate headform instrumented to measure linear and angular head responses. Subject and surrogate responses were compared with published injury assessment functions associated with mild traumatic brain injury (MTBI). Results: For ball impacts, none of the headgear provided attenuation over the full range of impact speeds. Head responses with or without headgear were not significantly different (p>0.05) and remained well below levels associated with MTBI. In head to head impact tests the headgear provided an overall 33% reduction in impact response. Conclusion: The football headgear models tested did not provide benefit during ball impact. This is probably because of the large amount of ball deformation relative to headband thickness. However, the headgear provided measurable benefit during head to head impacts. PMID:16046355
NASA Astrophysics Data System (ADS)
Diallo, S. O.; Lin, J. Y. Y.; Abernathy, D. L.; Azuah, R. T.
2016-11-01
Inelastic neutron scattering at high momentum transfers (i.e. Q ≥ 20 A ˚), commonly known as deep inelastic neutron scattering (DINS), provides direct observation of the momentum distribution of light atoms, making it a powerful probe for studying single-particle motions in liquids and solids. The quantitative analysis of DINS data requires an accurate knowledge of the instrument resolution function Ri(Q , E) at each momentum Q and energy transfer E, where the label i indicates whether the resolution was experimentally observed i = obs or simulated i=sim. Here, we describe two independent methods for determining the total resolution function Ri(Q , E) of the ARCS neutron instrument at the Spallation Neutron Source, Oak Ridge National Laboratory. The first method uses experimental data from an archetypical system (liquid 4He) studied with DINS, which are then numerically deconvoluted using its previously determined intrinsic scattering function to yield Robs(Q , E). The second approach uses accurate Monte Carlo simulations of the ARCS spectrometer, which account for all instrument contributions, coupled to a representative scattering kernel to reproduce the experimentally observed response S(Q , E). Using a delta function as scattering kernel, the simulation yields a resolution function Rsim(Q , E) with comparable lineshape and features as Robs(Q , E), but somewhat narrower due to the ideal nature of the model. Using each of these two Ri(Q , E) separately, we extract characteristic parameters of liquid 4He such as the intrinsic linewidth α2 (which sets the atomic kinetic energy 〈 K 〉 ∼α2) in the normal liquid and the Bose-Einstein condensate parameter n0 in the superfluid phase. The extracted α2 values agree well with previous measurements at saturated vapor pressure (SVP) as well as at elevated pressure (24 bars) within experimental precision, independent of which Ri(Q , y) is used to analyze the data. The actual observed n0 values at each Q vary little with the model Ri(Q , E), and the effective Q-averaged n0 values are consistent with each other, and with previously reported values.
Twelve-month follow-up of cognitive behavioral therapy for children with functional abdominal pain.
Levy, Rona L; Langer, Shelby L; Walker, Lynn S; Romano, Joan M; Christie, Dennis L; Youssef, Nader; DuPen, Melissa M; Ballard, Sheri A; Labus, Jennifer; Welsh, Ericka; Feld, Lauren D; Whitehead, William E
2013-02-01
To determine whether a brief intervention for children with functional abdominal pain and their parents' responses to their child's pain resulted in improved coping 12 months later. Prospective, randomized, longitudinal study. Families were recruited during a 4-year period in Seattle, Washington, and Morristown, New Jersey. Two hundred children with persistent functional abdominal pain and their parents. A 3-session social learning and cognitive behavioral therapy intervention or an education and support intervention. Child symptoms and pain-coping responses were monitored using standard instruments, as was parental response to child pain behavior. Data were collected at baseline and after treatment (1 week and 3, 6, and 12 months after treatment). This article reports the 12-month data. Relative to children in the education and support group, children in the social learning and cognitive behavioral therapy group reported greater baseline to 12-month follow-up decreases in gastrointestinal symptom severity (estimated mean difference, -0.36; 95% CI, -0.63 to -0.01) and greater improvements in pain-coping responses (estimated mean difference, 0.61; 95% CI, 0.26 to 1.02). Relative to parents in the education and support group, parents in the social learning and cognitive behavioral therapy group reported greater baseline to 12-month decreases in solicitous responses to their child's symptoms (estimated mean difference, -0.22; 95% CI, -0.42 to -0.03) and greater decreases in maladaptive beliefs regarding their child's pain (estimated mean difference, -0.36; 95% CI, -0.59 to -0.13). Results suggest long-term efficacy of a brief intervention to reduce parental solicitousness and increase coping skills. This strategy may be a viable alternative for children with functional abdominal pain. clinicaltrials.gov Identifier: NCT00494260.
ERIC Educational Resources Information Center
Gates, Philip E.; Otsuka, Norman Y.; Sanders, James O.; McGee-Brown, Jeanie
2008-01-01
Little data exists assessing the relationship between functional limitations in children with cerebral palsy (CP) and their participation in everyday activities. This prospective study evaluates the relationship between the Pediatric Outcomes Data Collection Instrument (PODCI), a functional health-related quality of life instrument for children…
Expectations for Visual Function: An Initial Evaluation of a New Clinical Instrument.
ERIC Educational Resources Information Center
Corn, Anne L.; Webne, Steve L.
2001-01-01
A study explored the internal consistency of items in a visual screening instrument developed by Project PAVE: Expectations for Visual Functioning (EVF). The test includes 20 items that evaluate a child's functional use of vision. A pilot test involving 129 teachers indicates the EFV is internally consistent. (Contains three references.) (CR)
ERIC Educational Resources Information Center
Marks, Ron
The study evaluated the validity, reliability, and effectiveness in providing needed information of the Montana Functional Vision Assessment (MFVA) Instrument by comparing it with the Texas Education Agency Functional Vision Assessment and field testing the instrument in evaluations of nine multihandicapped students (ages 3-11). Evaluation led to…
Azzopardi, Roberta Vella; Vermeiren, Sofie; Gorus, Ellen; Habbig, Ann-Katrin; Petrovic, Mirko; Van Den Noortgate, Nele; De Vriendt, Patricia; Bautmans, Ivan; Beyer, Ingo
2016-11-01
To date, the major dilemma concerning frailty is the lack of a standardized language regarding its operationalization. Considering the demographic challenge that the world is facing, standardization of frailty identification is indeed the first step in tackling the burdensome consequences of frailty. To demonstrate this diversity in frailty assessment, the available frailty instruments have been linked to the International Classification of Functioning, Disability, and Health (ICF): a standardized and hierarchically coded language developed by World Health Organization regarding health conditions and their positive (functioning) and negative (disability) consequences. A systematic review on frailty instruments was carried out in PubMed, Web of Knowledge, and PsycINFO. The items of the identified frailty instruments were then linked to the ICF codes. 79 original or adapted frailty instruments were identified and categorized into single (n = 25) and multidomain (n = 54) groups. Only 5 frailty instruments (indexes) were linked to all 5 ICF components. Whereas the ICF components Body Functions and Activities and Participation were frequently linked to the frailty instruments, Body Structures, Environmental and Personal factors were sparingly represented mainly in the multidomain frailty instruments. This review highlights the heterogeneity in frailty operationalization. Environmental and personal factors should be given more thought in future frailty assessments. Being unambiguous, structured, and neutral, the ICF language allows comparing observations made with different frailty instruments. In conclusion, this systematic overview and ICF translation can be a cornerstone for future standardization of frailty assessment. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
A new integrated instrumental approach to autonomic nervous system assessment.
Corazza, I; Barletta, G; Guaraldi, P; Cecere, A; Calandra-Buonaura, G; Altini, E; Zannoli, R; Cortelli, P
2014-11-01
The autonomic nervous system (ANS) regulates involuntary body functions and is commonly evaluated by measuring reflex responses of systolic and diastolic blood pressure (BP) and heart rate (HR) to physiological and pharmacological stimuli. However, BP and HR values may not sufficient be to explain specific ANS events and other parameters like the electrocardiogram (ECG), BP waves, the respiratory rate and the electroencephalogram (EEG) are mandatory. Although ANS behaviour and its response to stimuli are well-known, their clinical evaluation is often based on individual medical training and experience. As a result, ANS laboratories have been customized, making it impossible to standardize procedures and share results with colleagues. The aim of our study was to build a powerful versatile instrument easy-to-use in clinical practice to standardize procedures and allow a cross-analysis of all the parameters of interest for ANS evaluation. The new ANScovery System developed by neurologists and technicians is a two-step device: (1) integrating physiological information from different already existing commercial modules, making it possible to cross-analyse, store and share data; (2) standardizing procedures by an innovative tutor monitor able to guide the patient throughout ANS testing. The daily use of the new ANScovery System in clinical practice has proved it is a versatile easy to use instrument. Standardization of the manoeuvres and step-by-step guidance throughout the procedure avoid repetitions and allow intra and inter-patient data comparison. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Riu, Lucie; Bibring, Jean-Pierre; Pilorget, Cédric; Poulet, François; Hamm, Vincent
2018-03-01
The miniaturized near-infrared hyperspectral microscope MicrOmega, on board the MASCOT lander for Hayabusa-2 mission, is designed to perform in situ measurements at the grain scale of the C-type asteroid 1999 JU3 RYUGU. MicrOmega will observe samples with a field of view of a few millimeters with a spatial sampling of 25 μm and acquire near-infrared spectra by illuminating the sample sequentially with different wavelengths from 0.99 to 3.55 μm over two spectral channels with a typical spectral sampling of 20 cm-1. The on-ground calibration of MicrOmega requires a full characterization of the nominal range of operation of the instrument, both spectral (0.99-3.55 μm) and thermal (-40 °C to +40 °C) to derive the radiometric and spectral responses combined into a 4D transfer function to convert raw signal to calibrated reflectance. This specific 4D radiometric reference gives the instrument response according to the pixel location (x,y), the wavelength and the instrument temperature. This paper reports the complex computation of the 4D radiometric reference for the 0.9-2.5 μm channel. In this spectral range, the composition of the grains of a wide variety of minerals with relevance to solar system bodies can be identified through diagnostic spectral features: mafic (pyroxene, olivine…) as well as hydrated and altered minerals that are key phases for the solar system bodies' exploration.
The VIIRS Ocean Data Simulator Enhancements and Results
NASA Technical Reports Server (NTRS)
Robinson, Wayne D.; Patt, Fredrick S.; Franz, Bryan A.; Turpie, Kevin R.; McClain, Charles R.
2011-01-01
The VIIRS Ocean Science Team (VOST) has been developing an Ocean Data Simulator to create realistic VIIRS SDR datasets based on MODIS water-leaving radiances. The simulator is helping to assess instrument performance and scientific processing algorithms. Several changes were made in the last two years to complete the simulator and broaden its usefulness. The simulator is now fully functional and includes all sensor characteristics measured during prelaunch testing, including electronic and optical crosstalk influences, polarization sensitivity, and relative spectral response. Also included is the simulation of cloud and land radiances to make more realistic data sets and to understand their important influence on nearby ocean color data. The atmospheric tables used in the processing, including aerosol and Rayleigh reflectance coefficients, have been modeled using VIIRS relative spectral responses. The capabilities of the simulator were expanded to work in an unaggregated sample mode and to produce scans with additional samples beyond the standard scan. These features improve the capability to realistically add artifacts which act upon individual instrument samples prior to aggregation and which may originate from beyond the actual scan boundaries. The simulator was expanded to simulate all 16 M-bands and the EDR processing was improved to use these bands to make an SST product. The simulator is being used to generate global VIIRS data from and in parallel with the MODIS Aqua data stream. Studies have been conducted using the simulator to investigate the impact of instrument artifacts. This paper discusses the simulator improvements and results from the artifact impact studies.
The VIIRS ocean data simulator enhancements and results
NASA Astrophysics Data System (ADS)
Robinson, Wayne D.; Patt, Frederick S.; Franz, Bryan A.; Turpie, Kevin R.; McClain, Charles R.
2011-10-01
The VIIRS Ocean Science Team (VOST) has been developing an Ocean Data Simulator to create realistic VIIRS SDR datasets based on MODIS water-leaving radiances. The simulator is helping to assess instrument performance and scientific processing algorithms. Several changes were made in the last two years to complete the simulator and broaden its usefulness. The simulator is now fully functional and includes all sensor characteristics measured during prelaunch testing, including electronic and optical crosstalk influences, polarization sensitivity, and relative spectral response. Also included is the simulation of cloud and land radiances to make more realistic data sets and to understand their important influence on nearby ocean color data. The atmospheric tables used in the processing, including aerosol and Rayleigh reflectance coefficients, have been modeled using VIIRS relative spectral responses. The capabilities of the simulator were expanded to work in an unaggregated sample mode and to produce scans with additional samples beyond the standard scan. These features improve the capability to realistically add artifacts which act upon individual instrument samples prior to aggregation and which may originate from beyond the actual scan boundaries. The simulator was expanded to simulate all 16 M-bands and the EDR processing was improved to use these bands to make an SST product. The simulator is being used to generate global VIIRS data from and in parallel with the MODIS Aqua data stream. Studies have been conducted using the simulator to investigate the impact of instrument artifacts. This paper discusses the simulator improvements and results from the artifact impact studies.
Boj, Sylvia F; Vonk, Annelotte M; Statia, Marvin; Su, Jinyi; Vries, Robert R G; Beekman, Jeffrey M; Clevers, Hans
2017-02-11
Recently-developed cystic fibrosis transmembrane conductance regulator (CFTR)-modulating drugs correct surface expression and/or function of the mutant CFTR channel in subjects with cystic fibrosis (CF). Identification of subjects that may benefit from these drugs is challenging because of the extensive heterogeneity of CFTR mutations, as well as other unknown factors that contribute to individual drug efficacy. Here, we describe a simple and relatively rapid assay for measuring individual CFTR function and response to CFTR modulators in vitro. Three dimensional (3D) epithelial organoids are grown from rectal biopsies in standard organoid medium. Once established, the organoids can be bio-banked for future analysis. For the assay, 30-80 organoids are seeded in 96-well plates in basement membrane matrix and are then exposed to drugs. One day later, the organoids are stained with calcein green, and forskolin-induced swelling is monitored by confocal live cell microscopy at 37 °C. Forskolin-induced swelling is fully CFTR-dependent and is sufficiently sensitive and precise to allow for discrimination between the drug responses of individuals with different and even identical CFTR mutations. In vitro swell responses correlate with the clinical response to therapy. This assay provides a cost-effective approach for the identification of drug-responsive individuals, independent of their CFTR mutations. It may also be instrumental in the development of future CFTR modulators.
Cevasco, Andrea M; Grant, Roy E
2003-01-01
Many of the noted problems associated with Alzheimer's disease (AD) sometimes can be delayed, retarded, or even reversed with proper exercise and interaction with the environment. An overwhelming body of research efforts has revealed that music activity brings about the greatest degree of responsiveness, including exercise, in clients with AD; yet, specific techniques which elicit the greatest amount of physical responses during the music activities remain unidentified. The purpose of this study was two-fold: comparing two methods of intervention and comparing responses to vocal versus instrumental music during exercise and exercise with instruments. In Experiment 1 the authors compared 2 treatment conditions to facilitate exercise during music activities: (a) verbalizing the movement for each task once, one beat before commencing, followed by visual cueing for the remainder of the task; (b) verbal and visual cueing for each revolution or change in rhythm for the duration of the task. Data collection over 38 sessions consisted of recording the participation of each client at 30-second intervals for the duration of each treatment condition, indicating at each interval whether the client was participating in the designated movement (difficult), participating in exercise approximating the designated movement (easy), or not participating. Results indicated that the continuous verbal cueing/easy treatment elicited significantly greater participation than one verbal cue/difficult treatment, p <.05. Furthermore, the approximation/precise response (easy) resulted in significantly greater responses than the precise response (difficult), p < .001. In Experiment 2 the responses to types of music, vocal versus instrumental, during types of activities, exercise with and without instruments, were examined. Data were collected over 26 sessions, 52 activities, in the same 2 assisted living facilities as those in Experiment 1, but one year later Results indicated that both the type of activity and the type of music had some effect on participation. Also, data indicated participation in exercise to instrumental music was significantly greater than exercise with instruments to vocal music, p <.05.
Individual differences in bodily freezing predict emotional biases in decision making
Ly, Verena; Huys, Quentin J. M.; Stins, John F.; Roelofs, Karin; Cools, Roshan
2014-01-01
Instrumental decision making has long been argued to be vulnerable to emotional responses. Literature on multiple decision making systems suggests that this emotional biasing might reflect effects of a system that regulates innately specified, evolutionarily preprogrammed responses. To test this hypothesis directly, we investigated whether effects of emotional faces on instrumental action can be predicted by effects of emotional faces on bodily freezing, an innately specified response to aversive relative to appetitive cues. We tested 43 women using a novel emotional decision making task combined with posturography, which involves a force platform to detect small oscillations of the body to accurately quantify postural control in upright stance. On the platform, participants learned whole body approach-avoidance actions based on monetary feedback, while being primed by emotional faces (angry/happy). Our data evidence an emotional biasing of instrumental action. Thus, angry relative to happy faces slowed instrumental approach relative to avoidance responses. Critically, individual differences in this emotional biasing effect were predicted by individual differences in bodily freezing. This result suggests that emotional biasing of instrumental action involves interaction with a system that controls innately specified responses. Furthermore, our findings help bridge (animal and human) decision making and emotion research to advance our mechanistic understanding of decision making anomalies in daily encounters as well as in a wide range of psychopathology. PMID:25071491
Analysis of In Situ Thermal Ion Measurements from the MICA Sounding Rocket
NASA Astrophysics Data System (ADS)
Fernandes, P. A.; Lynch, K. A.; Zettergren, M. D.; Hampton, D. L.; Fisher, L. E.; Powell, S. P.
2014-12-01
The MICA sounding rocket launched on 19 Feb. 2012 into several discrete, localized arcs in the wake of a westward traveling surge. In situ and ground-based observations provide a measured response of the ionosphere to preflight and localized auroral drivers. Initial analysis of the in situ thermal ion data indicate possible measurement of an ion conic at low altitude (< 325 km). In the low-energy regime, the response of the instrument varies from the ideal because the measured thermal ion population is sensitive to the presence of the instrument. The plasma is accelerated in the frame of the instrument due to flows, ram, and acceleration through the sheath which forms around the spacecraft. The energies associated with these processes are large compared to the thermal energy. Correct interpretation of thermal plasma measurements requires accounting for all of these plasma processes and the non-ideal response of the instrument in the low-energy regime. This is an experimental and modeling project which involves thorough analysis of ionospheric thermal ion data from the MICA campaign. Analysis includes modeling and measuring the instrument response in the low-energy regime as well as accounting for the complex sheath formed around the instrument. This results in a forward model in which plasma parameters of the thermal plasma are propagated through the sheath and instrument models, resulting in an output which matches the in situ measurement. In the case of MICA, we are working toward answering the question of the initiating source processes that result, at higher altitudes, in well-developed conics and outflow on auroral field lines.
Pareidolias in REM Sleep Behavior Disorder: A Possible Predictive Marker of Lewy Body Diseases?
Sasai-Sakuma, Taeko; Nishio, Yoshiyuki; Yokoi, Kayoko; Mori, Etsuro; Inoue, Yuichi
2017-02-01
To investigate conditions and clinical significance of pareidolias in patients with idiopathic rapid eyemovent (REM) sleep behavior disorder (iRBD). This cross-sectional study examined 202 patients with iRBD (66.8 ± 8.0 yr, 58 female) and 46 healthy control subjects (64.7 ± 5.8 years, 14 females). They underwent the Pareidolia test, a newly developed instrument for evoking pareidolias, video polysomnography, olfactory tests, and Addenbrooke's cognitive examination-revised. Results show that 53.5% of iRBD patients exhibited one or more pareidolic responses: The rate was higher than control subjects showed (21.7%). The pictures evoking pareidolic responses were more numerous for iRBD patients than for control subjects (1.2 ± 1.8 vs. 0.4 ± 0.8, p < .001). Subgroup analyses revealed that iRBD patients with pareidolic responses had higher amounts of REM sleep without atonia (RWA), with lower sleep efficiency, lower cognitive function, and older age than subjects without pareidolic responses. Results of multivariate analyses show the number of pareidolic responses as a factor associated with decreased cognitive function in iRBD patients with better predictive accuracy. Morbidity length and severity of iRBD, olfactory function, and the amount of RWA were not factors associated with better predictive accuracy. Half or more of the iRBD patients showed pareidolic responses. The responses were proven to be associated more intimately with their cognitive decline than clinical or physiological variables related to RBD. Pareidolias in iRBD are useful as a predictive marker of future development of Lewy body diseases. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.
Idea Bank: Does Your Health Depend on a Clean Instrument?
ERIC Educational Resources Information Center
Gutoff, Olivia W.
2011-01-01
Music teachers have a responsibility to give detailed instruction on the regular cleaning of brass and wind instruments because of new, compelling research. Recent findings reinforce the importance of teaching proper instrument cleaning. Serious health consequences can be avoided by making instrument care an integral part of the educative process.…
Parallel Study of HEND, RAD, and DAN Instrument Response to Martian Radiation and Surface Conditions
NASA Technical Reports Server (NTRS)
Martiniez Sierra, Luz Maria; Jun, Insoo; Litvak, Maxim; Sanin, Anton; Mitrofanov, Igor; Zeitlin, Cary
2015-01-01
Nuclear detection methods are being used to understand the radiation environment at Mars. JPL (Jet Propulsion Laboratory) assets on Mars include: Orbiter -2001 Mars Odyssey [High Energy Neutron Detector (HEND)]; Mars Science Laboratory Rover -Curiosity [(Radiation Assessment Detector (RAD); Dynamic Albedo Neutron (DAN))]. Spacecraft have instruments able to detect ionizing and non-ionizing radiation. Instrument response on orbit and on the surface of Mars to space weather and local conditions [is discussed] - Data available at NASA-PDS (Planetary Data System).
Age-Related Changes in Bimanual Instrument Playing with Rhythmic Cueing
Kim, Soo Ji; Cho, Sung-Rae; Yoo, Ga Eul
2017-01-01
Deficits in bimanual coordination of older adults have been demonstrated to significantly limit their functioning in daily life. As a bimanual sensorimotor task, instrument playing has great potential for motor and cognitive training in advanced age. While the process of matching a person’s repetitive movements to auditory rhythmic cueing during instrument playing was documented to involve motor and attentional control, investigation into whether the level of cognitive functioning influences the ability to rhythmically coordinate movement to an external beat in older populations is relatively limited. Therefore, the current study aimed to examine how timing accuracy during bimanual instrument playing with rhythmic cueing differed depending on the degree of participants’ cognitive aging. Twenty one young adults, 20 healthy older adults, and 17 older adults with mild dementia participated in this study. Each participant tapped an electronic drum in time to the rhythmic cueing provided using both hands simultaneously and in alternation. During bimanual instrument playing with rhythmic cueing, mean and variability of synchronization errors were measured and compared across the groups and the tempo of cueing during each type of tapping task. Correlations of such timing parameters with cognitive measures were also analyzed. The results showed that the group factor resulted in significant differences in the synchronization errors-related parameters. During bimanual tapping tasks, cognitive decline resulted in differences in synchronization errors between younger adults and older adults with mild dimentia. Also, in terms of variability of synchronization errors, younger adults showed significant differences in maintaining timing performance from older adults with and without mild dementia, which may be attributed to decreased processing time for bimanual coordination due to aging. Significant correlations were observed between variability of synchronization errors and performance of cognitive tasks involving executive control and cognitive flexibility when asked for bimanual coordination in response to external timing cues at adjusted tempi. Also, significant correlations with cognitive measures were more prevalent in variability of synchronization errors during alternative tapping compared to simultaneous tapping. The current study supports that bimanual tapping may be predictive of cognitive processing of older adults. Also, tempo and type of movement required for instrument playing both involve cognitive and motor loads at different levels, and such variables could be important factors for determining the complexity of the task and the involved task requirements for interventions using instrument playing. PMID:29085309
Independent Orbiter Assessment (IOA): Analysis of the instrumentation subsystem
NASA Technical Reports Server (NTRS)
Howard, B. S.
1986-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Instrumentation Subsystem are documented. The Instrumentation Subsystem (SS) consists of transducers, signal conditioning equipment, pulse code modulation (PCM) encoding equipment, tape recorders, frequency division multiplexers, and timing equipment. For this analysis, the SS is broken into two major groupings: Operational Instrumentation (OI) equipment and Modular Auxiliary Data System (MADS) equipment. The OI equipment is required to acquire, condition, scale, digitize, interleave/multiplex, format, and distribute operational Orbiter and payload data and voice for display, recording, telemetry, and checkout. It also must provide accurate timing for time critical functions for crew and payload specialist use. The MADS provides additional instrumentation to measure and record selected pressure, temperature, strain, vibration, and event data for post-flight playback and analysis. MADS data is used to assess vehicle responses to the flight environment and to permit correlation of such data from flight to flight. The IOA analysis utilized available SS hardware drawings and schematics for identifying hardware assemblies and components and their interfaces. Criticality for each item was assigned on the basis of the worst-case effect of the failure modes identified.
A Community Assessment Tool for Education Resources
NASA Astrophysics Data System (ADS)
Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.
2016-12-01
In order to facilitate and enhance better understanding of how to conserve life on earth and the environment that sustains it, Data Observation Network for Earth (DataONE) develops, implements, and shares educational activities and materials as part of its commitment to the education of its community, including scientific researchers, educators, and the public. Creating and maintaining educational materials that remain responsive to community needs is reliant on careful evaluations in order to enhance current and future resources. DataONE's extensive collaboration with individuals and organizations has informed the development of its educational resources and through these interactions, the need for a comprehensive, customizable education evaluation instrument became apparent. In this presentation, the authors will briefly describe the design requirements and research behind a prototype instrument that is intended to be used by the community for evaluation of its educational activities and resources. We will then demonstrate the functionality of a web based platform that enables users to identify the type of educational activity across multiple axes. This results in a set of structured evaluation questions that can be included in a survey instrument. Users can also access supporting documentation describing the types of question included in the output or simply download a full editable instrument. Our aim is that by providing the community with access to a structured evaluation instrument, Earth/Geoscience educators will be able to gather feedback easily and efficiently in order to help maintain the quality, currency/relevancy, and value of their resources, and ultimately, support a more data literate community.
40 CFR 86.884-11 - Instrument checks.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equipment response of zero; (3) Calibrated neutral density filters having approximately 10, 20, and 40 percent opacity shall be employed to check the linearity of the instrument. The filter(s) shall be... beam of light from the light source emanates, and the recorder response shall be noted. Filters with...
Schmidt, Stefanie; Garin, Olatz; Pardo, Yolanda; Valderas, José M; Alonso, Jordi; Rebollo, Pablo; Rajmil, Luis; Garcia-Forero, Carlos; Ferrer, Montse
2014-10-01
The objective was to obtain a standardized evaluation of available prostate cancer-specific quality of life instruments used in patients with early-stage disease. We carried out systematic literature reviews in the PubMed database to identify manuscripts which contained information regarding either the development process or metric properties of prostate cancer-specific quality of life instruments. Each instrument was evaluated by two experts, independently, using the Evaluating Measures of Patient-Reported Outcomes (EMPRO) tool. An overall and seven attribute-specific EMPRO scores were calculated (range 0-100, worst to best): measurement model, reliability, validity, responsiveness, interpretability, burden and alternative forms. Eight instruments and 57 manuscripts (2-15 per instrument) were identified. The Expanded Prostate Cancer Index Composite (EPIC) was the best rated (overall EMPRO score 83.1 points). Good results were also obtained by University of California Los Angeles-Prostate Cancer Index (UCLA-PCI), Patient-Oriented Prostate Utility Scale (PORPUS) and Prostate Cancer Quality of Life Instrument (PC-QoL) with 77.3, 70.5 and 64.8 points, respectively. These four instruments passed with distinction the validity and responsiveness evaluation. Insufficient reliability results were observed for UCLA-PCI and PORPUS. Current evidence supports the choice of EPIC, PORPUS or PC-QoL. Attribute-specific EMPRO results facilitate selecting the adequate instrument for every purpose. For longitudinal studies or clinical trials, where responsiveness is the priority, EPIC or PC-QoL should be considered. We recommend the PORPUS for economic evaluations because it allows cost-utility analysis, and EPIC short versions to minimize administration burden.
A Comprehensive Review of Sensors and Instrumentation Methods in Devices for Musical Expression
Medeiros, Carolina Brum; Wanderley, Marcelo M.
2014-01-01
Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009–2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments. PMID:25068865
A comprehensive review of sensors and instrumentation methods in devices for musical expression.
Medeiros, Carolina Brum; Wanderley, Marcelo M
2014-07-25
Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009-2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments.
NASA Astrophysics Data System (ADS)
Zhang, Jie; Marto, Joseph P.; Schwab, James J.
2018-05-01
Two optical scattering instruments for particle mass measurement, the Thermo Personal Data RAM (PDR-1500) and the TSI Environmental DustTrak DRX (Model 8543) were evaluated by (1) using poly- and mono-disperse test aerosol in the laboratory, and (2) sampling ambient aerosol. The responses of these optical scattering instruments to different particle characteristics (size, composition, concentration) were compared with responses from reference instruments. A Mie scattering calculation was used to explain the dependence of the optical instruments' response to aerosol size and composition. Concurrently, the detection efficiency of one Alphasense Optical Particle Counter (OPC-N2) was evaluated in the laboratory as well. The relationship between aerosol mass concentration and optical scattering was determined to be strongly dependent on aerosol size and to a lesser extent on aerosol composition (as reflected in the refractive indices of the materials tested) based on ambient measurements. This confirms that there is no simple way to use optical scattering instruments over a wide range of conditions without adjustments based on knowledge of aerosol size and composition. In particular, a test period measuring ambient aerosol with optical scattering instruments and a mass based method (an Aerodyne Aerosol Mass Spectrometer) determined that roughly two thirds of the variance (R2 = 0.64) of the optical to mass signal ratio is explained by the aerosol mass median diameter alone. These observations and calculations help evaluate the applicability and limitations of these optical scattering instruments, and provide guidance to designing suitable applications for each instrument by considering aerosol sources and aerosol size.
Using ACIS on the Chandra X-ray Observatory as a Particle Radiation Monitor II
NASA Technical Reports Server (NTRS)
Grant, C. E.; Ford, P. G.; Bautz, M. W.; ODell, S. L.
2012-01-01
The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced the effectiveness of the on-board monitor. The ACIS team has developed an algorithm which uses data from the CCDs themselves to detect periods of high radiation and a flight software patch to apply this algorithm is currently active on-board the instrument. In this paper, we explore the ACIS response to particle radiation through comparisons to a number of external measures of the radiation environment. We hope to better understand the efficiency of the algorithm as a function of the flux and spectrum of the particles and the time-profile of the radiation event.
Seismic response analysis of an instrumented building structure
Li, H.-J.; Zhu, S.-Y.; Celebi, M.
2003-01-01
The Sheraton - Universal hotel, an instrumented building lying in North Hollywood, USA is selected for case study in this paper. The finite element method is used to produce a linear time - invariant structural model, and the SAP2000 program is employed for the time history analysis of the instrumented structure under the base excitation of strong motions recorded in the basement during the Northridge, California earthquake of 17 January 1994. The calculated structural responses are compared with the recorded data in both time domain and frequency domain, and the effects of structural parameters evaluation and indeterminate factors are discussed. Some features of structural response, such as the reason why the peak responses of acceleration in the ninth floor are larger than those in the sixteenth floor, are also explained.
Characterizing nonconstant instrumental variance in emerging miniaturized analytical techniques.
Noblitt, Scott D; Berg, Kathleen E; Cate, David M; Henry, Charles S
2016-04-07
Measurement variance is a crucial aspect of quantitative chemical analysis. Variance directly affects important analytical figures of merit, including detection limit, quantitation limit, and confidence intervals. Most reported analyses for emerging analytical techniques implicitly assume constant variance (homoskedasticity) by using unweighted regression calibrations. Despite the assumption of constant variance, it is known that most instruments exhibit heteroskedasticity, where variance changes with signal intensity. Ignoring nonconstant variance results in suboptimal calibrations, invalid uncertainty estimates, and incorrect detection limits. Three techniques where homoskedasticity is often assumed were covered in this work to evaluate if heteroskedasticity had a significant quantitative impact-naked-eye, distance-based detection using paper-based analytical devices (PADs), cathodic stripping voltammetry (CSV) with disposable carbon-ink electrode devices, and microchip electrophoresis (MCE) with conductivity detection. Despite these techniques representing a wide range of chemistries and precision, heteroskedastic behavior was confirmed for each. The general variance forms were analyzed, and recommendations for accounting for nonconstant variance discussed. Monte Carlo simulations of instrument responses were performed to quantify the benefits of weighted regression, and the sensitivity to uncertainty in the variance function was tested. Results show that heteroskedasticity should be considered during development of new techniques; even moderate uncertainty (30%) in the variance function still results in weighted regression outperforming unweighted regressions. We recommend utilizing the power model of variance because it is easy to apply, requires little additional experimentation, and produces higher-precision results and more reliable uncertainty estimates than assuming homoskedasticity. Copyright © 2016 Elsevier B.V. All rights reserved.
SOFIA tracking image simulation
NASA Astrophysics Data System (ADS)
Taylor, Charles R.; Gross, Michael A. K.
2016-09-01
The Stratospheric Observatory for Infrared Astronomy (SOFIA) tracking camera simulator is a component of the Telescope Assembly Simulator (TASim). TASim is a software simulation of the telescope optics, mounting, and control software. Currently in its fifth major version, TASim is relied upon for telescope operator training, mission planning and rehearsal, and mission control and science instrument software development and testing. TASim has recently been extended for hardware-in-the-loop operation in support of telescope and camera hardware development and control and tracking software improvements. All three SOFIA optical tracking cameras are simulated, including the Focal Plane Imager (FPI), which has recently been upgraded to the status of a science instrument that can be used on its own or in parallel with one of the seven infrared science instruments. The simulation includes tracking camera image simulation of starfields based on the UCAC4 catalog at real-time rates of 4-20 frames per second. For its role in training and planning, it is important for the tracker image simulation to provide images with a realistic appearance and response to changes in operating parameters. For its role in tracker software improvements, it is vital to have realistic signal and noise levels and precise star positions. The design of the software simulation for precise subpixel starfield rendering (including radial distortion), realistic point-spread function as a function of focus, tilt, and collimation, and streaking due to telescope motion will be described. The calibration of the simulation for light sensitivity, dark and bias signal, and noise will also be presented
NIH EXAMINER: conceptualization and development of an executive function battery.
Kramer, Joel H; Mungas, Dan; Possin, Katherine L; Rankin, Katherine P; Boxer, Adam L; Rosen, Howard J; Bostrom, Alan; Sinha, Lena; Berhel, Ashley; Widmeyer, Mary
2014-01-01
Executive functioning is widely targeted when human cognition is assessed, but there is little consensus on how it should be operationalized and measured. Recognizing the difficulties associated with establishing standard operational definitions of executive functioning, the National Institute of Neurological Disorders and Stroke entered into a contract with the University of California-San Francisco to develop psychometrically robust executive measurement tools that would be accepted by the neurology clinical trials and clinical research communities. This effort, entitled Executive Abilities: Measures and Instruments for Neurobehavioral Evaluation and Research (EXAMINER), resulted in a series of tasks targeting working memory, inhibition, set shifting, fluency, insight, planning, social cognition and behavior. We describe battery conceptualization and development, data collection, scale construction based on item response theory, and lay the foundation for studying the battery's utility and validity for specific assessment and research goals.
Elderly Care and Intrafamily Resource Allocation when Children Migrate.
Antman, Francisca M
2012-01-01
This paper considers the intrafamily allocation of elderly care in the context of international migration where migrant children may be able to provide financial assistance to their parents, but are unable to offer physical care. To investigate the interaction between siblings, I take a non-cooperative view of family decision-making and estimate best response functions for individual physical and financial contributions as a function of siblings' contributions. I address the endogeneity of siblings' contributions and individual migration decisions by using siblings' characteristics as instrumental variables as well as models including family fixed effects. For both migrants and non-migrants, I find evidence that financial contributions function as strategic complements while siblings' time contributions operate as strategic substitutes. This suggests that children's contributions toward elderly care may be based on both strategic bequest and public good motivations.
Elderly Care and Intrafamily Resource Allocation when Children Migrate *
Antman, Francisca M.
2012-01-01
This paper considers the intrafamily allocation of elderly care in the context of international migration where migrant children may be able to provide financial assistance to their parents, but are unable to offer physical care. To investigate the interaction between siblings, I take a non-cooperative view of family decision-making and estimate best response functions for individual physical and financial contributions as a function of siblings’ contributions. I address the endogeneity of siblings’ contributions and individual migration decisions by using siblings’ characteristics as instrumental variables as well as models including family fixed effects. For both migrants and non-migrants, I find evidence that financial contributions function as strategic complements while siblings’ time contributions operate as strategic substitutes. This suggests that children’s contributions toward elderly care may be based on both strategic bequest and public good motivations. PMID:22518064
Error-in-variables models in calibration
NASA Astrophysics Data System (ADS)
Lira, I.; Grientschnig, D.
2017-12-01
In many calibration operations, the stimuli applied to the measuring system or instrument under test are derived from measurement standards whose values may be considered to be perfectly known. In that case, it is assumed that calibration uncertainty arises solely from inexact measurement of the responses, from imperfect control of the calibration process and from the possible inaccuracy of the calibration model. However, the premise that the stimuli are completely known is never strictly fulfilled and in some instances it may be grossly inadequate. Then, error-in-variables (EIV) regression models have to be employed. In metrology, these models have been approached mostly from the frequentist perspective. In contrast, not much guidance is available on their Bayesian analysis. In this paper, we first present a brief summary of the conventional statistical techniques that have been developed to deal with EIV models in calibration. We then proceed to discuss the alternative Bayesian framework under some simplifying assumptions. Through a detailed example about the calibration of an instrument for measuring flow rates, we provide advice on how the user of the calibration function should employ the latter framework for inferring the stimulus acting on the calibrated device when, in use, a certain response is measured.
Ventral pallidal encoding of reward-seeking behavior depends on the underlying associative structure
Stout, Nakura; Acs, Deanna
2018-01-01
Despite its being historically conceptualized as a motor expression site, emerging evidence suggests the ventral pallidum (VP) plays a more active role in integrating information to generate motivation. Here, we investigated whether rat VP cue responses would encode and contribute similarly to the vigor of reward-seeking behaviors trained under Pavlovian versus instrumental contingencies, when these behavioral responses consist of superficially similar locomotor response patterns but may reflect distinct underlying decision-making processes. We find that cue-elicited activity in many VP neurons predicts the latency of instrumental reward seeking, but not of Pavlovian response latency. Further, disruption of VP signaling increases the latency of instrumental but not Pavlovian reward seeking. This suggests that VP encoding of and contributions to response vigor are specific to the ability of incentive cues to invigorate reward-seeking behaviors upon which reward delivery is contingent. PMID:29565248
Overview of practice management in child and adolescent psychiatry.
Schreter, Robert K
2010-01-01
The manager of a psychiatric practice must create and direct a clinical delivery system, design and oversee the administrative services necessary to support the system, and guide the business operations that contribute to its success. Regardless of the size of the practice, the psychiatrist administrator must handle seven core administrative responsibilities and oversee individual functions and capabilities within each domain. These responsibilities include practice development, clinical services management, medical office operations, clinical management, information management, business management, and risk management. This article provides a roadmap for creating and sustaining successful clinical and administrative endeavors. It can also be used by existing practices as an audit instrument to provide a snapshot of current capabilities so that strengths as well as opportunities for continued growth can be identified.
The EOSDIS Products Usability for Disaster Response
NASA Technical Reports Server (NTRS)
Kafle, Durga N.; Wanchoo, Lalit; Won, Young-In; Michael, Karen
2016-01-01
The focus of the study is to categorize both NRT and standard data products based on applicability to the SDR-defined disaster types. This will identify which datasets from current NASA satellite missions instruments are best suited for disaster response. The distribution metrics of the products that have been used for studying various selected disasters that have occurred over last 5 years will be analyzed that include volume, number of files, number of users, user domains, user country, etc. This data usage analysis will provide information to the data centers staff that can help them develop the functionality and allocate the resources needed for enhanced access and timely availability of the data products that are critical for the time-sensitive analyses.
Development of a portable multispectral thermal infrared camera
NASA Technical Reports Server (NTRS)
Osterwisch, Frederick G.
1991-01-01
The purpose of this research and development effort was to design and build a prototype instrument designated the 'Thermal Infrared Multispectral Camera' (TIRC). The Phase 2 effort was a continuation of the Phase 1 feasibility study and preliminary design for such an instrument. The completed instrument designated AA465 has application in the field of geologic remote sensing and exploration. The AA465 Thermal Infrared Camera (TIRC) System is a field-portable multispectral thermal infrared camera operating over the 8.0 - 13.0 micron wavelength range. Its primary function is to acquire two-dimensional thermal infrared images of user-selected scenes. Thermal infrared energy emitted by the scene is collected, dispersed into ten 0.5 micron wide channels, and then measured and recorded by the AA465 System. This multispectral information is presented in real time on a color display to be used by the operator to identify spectral and spatial variations in the scenes emissivity and/or irradiance. This fundamental instrument capability has a wide variety of commercial and research applications. While ideally suited for two-man operation in the field, the AA465 System can be transported and operated effectively by a single user. Functionally, the instrument operates as if it were a single exposure camera. System measurement sensitivity requirements dictate relatively long (several minutes) instrument exposure times. As such, the instrument is not suited for recording time-variant information. The AA465 was fabricated, assembled, tested, and documented during this Phase 2 work period. The detailed design and fabrication of the instrument was performed during the period of June 1989 to July 1990. The software development effort and instrument integration/test extended from July 1990 to February 1991. Software development included an operator interface/menu structure, instrument internal control functions, DSP image processing code, and a display algorithm coding program. The instrument was delivered to NASA in March 1991. Potential commercial and research uses for this instrument are in its primary application as a field geologists exploration tool. Other applications have been suggested but not investigated in depth. These are measurements of process control in commercial materials processing and quality control functions which require information on surface heterogeneity.
Scott, Elizabeth; Glass, Natalie; Wolf, Brian R.; Hettrich, Carolyn M.; Bollier, Matthew
2018-01-01
Objectives: Anterior cruciate ligament reconstruction is a commonly performed orthopaedic procedure. PROMIS (Patient-Reported Outcome Measurement Information System) was developed by the National Institutes of Health in an effort to advance patient-reported outcome (PRO) instruments by developing question banks for major health domains. Our goal was to compare the responsiveness and construct validity of the PROMIS physical function (PF) computer adaptive test (CAT) with current PRO instruments utilized in patients who undergo anterior cruciate ligament reconstruction. Methods: A total of 174 patients ages 14-53 scheduled to undergo anterior cruciate ligament reconstruction were asked to complete PROMIS PF-CAT, Short Form-36 Health Survey (SF36-PF and -GH), Marx activity rating scale (Marx), Knee Injury and Osteoarthritis Score (KOOS-ADL, -Sport, -QOL), and the EuroQol five dimensions questionnaire (EQ5D) at their preoperative visit. These surveys were repeated at six weeks and six months after surgery. Correlations between PRO instruments was defined as excellent (>0.7), excellent-good (0.61-0.7), good (0.4-0.6), and poor (0.2-0.3) using Spearman Correlation Coefficients. The effect size (Cohen d) and standardized response mean (SRM) were used to describe the responsiveness of each PRO at the 6 week and 6 month follow-up visits and were defined as small (0.2), medium (0.5) and large (0.8). Ceiling and floor effects were defined as present if ≥15% of participants scored the highest or lowest score on a PRO, respectively. Subgroup analyses were performed comparing change in PRO scores at follow-up between participants with and without additional arthroscopic procedures (meniscal debridement and/or repair, microfracture, or OATS vs ACL reconstruction only) using linear mixed models. Results: There were excellent and excellent-good correlations between the PROMIS PF-CAT and physical function PROs including the SF36-PF (r=0.75-0.80, p<.01), KOOS-ADL (r=0.62-0.70, p<.01) and KOOS-Sport (r=0.32-0.69, p<0.01) at most time points, respectively. There was also excellent-good correlation with the EQ5D (r=0.60-0.71, p<.01) and good correlation with the KOOS-QOL (r=0.52-0.58, p<0.01). As expected, there was no (p>0.05) to poor correlation with Marx activity (r=0.24, p<0.01) and the SF36-GH (r=0.32-0.34, p<0.01). No ceiling or floor effects were noted for the PROMIS PF-CAT; there was a ceiling effect noted for KOOS-ADL at the 6 month visit (38.1%). Effect size estimates for physical function PROs increased from small to large changes from the 6 week to 6 month visits and were largest in the PROMIS PF-CAT (1.34) followed by KOOS-ADL (1.19) and SF36-PF (1.06). Patients answered on average 4 questions utilizing the PROMIS. Baseline subgroup analyses showed no significant differences in physical function PRO scores, and at follow-up, both groups showed significant improvement in physical function PRO scores that was not statistically different. Conclusion: Our results support the construct validity of the PROMIS PF-CAT in patients who undergo ACL reconstruction. Responsiveness to change was highest by 6 months postop and greater for the PROMIS PF-CAT than for other measures of physical function with no ceiling or floor effects and a low time-burden. Taken together, these findings suggest that the PROMIS PF-CAT is a beneficial alternative to measuring and tracking changes in physical function in adults undergoing ACL reconstruction.
Evidence for an expectancy-based theory of avoidance behaviour.
Declercq, Mieke; De Houwer, Jan; Baeyens, Frank
2008-01-01
In most studies on avoidance learning, participants receive an aversive unconditioned stimulus after a warning signal is presented, unless the participant performs a particular response. Lovibond (2006) recently proposed a cognitive theory of avoidance learning, according to which avoidance behaviour is a function of both Pavlovian and instrumental conditioning. In line with this theory, we found that avoidance behaviour was based on an integration of acquired knowledge about, on the one hand, the relation between stimuli and, on the other hand, the relation between behaviour and stimuli.
Motivational deficits after brain injury: effects of bromocriptine in 11 patients.
Powell, J H; al-Adawi, S; Morgan, J; Greenwood, R J
1996-01-01
OBJECTIVE: To test the hypothesis that treatment with bromocriptine would ameliorate deficits in clinical motivation, responsiveness to reward, and frontal cognitive function after brain injury. METHOD: An open trial in six men and five women who had had either traumatic brain injury or subarachnoid haemorrhage between two months and five years previously. After repeated baseline assessments, bromocriptine was given in gradually increasing doses. Assessments were repeated at increasing doses, during maintenance, and after withdrawal. Novel structured instruments for quantifying motivation were developed; measures of anxiety and depression, and cognitive tests sensitive to motivation or frontal lobe involvement were also given. RESULTS: Bromocriptine treatment was followed by improved scores on all measures other than mood. Improvement was maintained after bromocriptine withdrawal in eight of the patients. CONCLUSION: Poor motivation in patients with brain injury may result from dysfunction in the mesolimbic/mesocortical dopaminergic circuitry, giving rise to associated deficiencies in reward responsiveness and frontal cognitive function. PMID:8774407
Development of a real-time transport performance optimization methodology
NASA Technical Reports Server (NTRS)
Gilyard, Glenn
1996-01-01
The practical application of real-time performance optimization is addressed (using a wide-body transport simulation) based on real-time measurements and calculation of incremental drag from forced response maneuvers. Various controller combinations can be envisioned although this study used symmetric outboard aileron and stabilizer. The approach is based on navigation instrumentation and other measurements found on state-of-the-art transports. This information is used to calculate winds and angle of attack. Thrust is estimated from a representative engine model as a function of measured variables. The lift and drag equations are then used to calculate lift and drag coefficients. An expression for drag coefficient, which is a function of parasite drag, induced drag, and aileron drag, is solved from forced excitation response data. Estimates of the parasite drag, curvature of the aileron drag variation, and minimum drag aileron position are produced. Minimum drag is then obtained by repositioning the symmetric aileron. Simulation results are also presented which evaluate the affects of measurement bias and resolution.