LST and instrument considerations. [modular design
NASA Technical Reports Server (NTRS)
Levin, G. M.
1974-01-01
In order that the LST meet its scientific objectives and also be a National Astronomical Space Facility during the 1980's and 1990's, broad requirements have been levied by the scientific community. These scientific requirements can be directly translated into design requirements and specifications for the scientific instruments. The instrument ensemble design must be consistent with a 15-year operational lifetime. Downtime for major repair/refurbishment or instrument updating must be minimized. The overall efficiency and performance of the instruments should be maximized. Modularization of instruments and instrument subsystems, some degree of on-orbit servicing (both repair and replacement), on-axis location, minimizing the number of reflections within instruments, minimizing polarization effects, and simultaneous operation of the F/24 camera with other instruments, are just a few of the design guidelines and specifications which can and will be met in order that these broader scientific requirements be satisfied.-
Students' Initial Knowledge State and Test Design: Towards a Valid and Reliable Test Instrument
ERIC Educational Resources Information Center
CoPo, Antonio Roland I.
2015-01-01
Designing a good test instrument involves specifications, test construction, validation, try-out, analysis and revision. The initial knowledge state of forty (40) tertiary students enrolled in Business Statistics course was determined and the same test instrument undergoes validation. The designed test instrument did not only reveal the baseline…
NASA Astrophysics Data System (ADS)
Baffa, Carlo; Gennari, Sandro; Hunt, Leslie K.; Lisi, Franco; Tofani, Gianni; Vanzi, Leonardo
1995-09-01
We describe the general characteristics of the TIRGO infrared telescope, located on Gornergrat (Switzerland), and its most recent instrumentation. This telescope is specifically designed for infrared astronomical observations. Two newly designed instruments are presented: the imaging camera Arnica and the long-slit spectrometer LonGSp, both based on two-dimensional array detectors.
Harvard ER-2 OH laser-induced fluorescence instrument
NASA Technical Reports Server (NTRS)
Wennberg, Paul O.; Anderson, James G.
1994-01-01
The Harvard ER-2 OH instrument is scheduled to be integrated into the NASA ER-2 high altitude aircraft ozone payload in August 1992. Design and fabrication is presently underway. This experiment is a descendant of a balloon borne instrument designed and built in the mid-1980s. The ER-2 instrument is being designed to measure OH and HO2 as part of the NASA ozone payload for the investigation of processes controlling the concentration of stratospheric ozone. Although not specifically designed to do so, it is hoped that valid measurements of OH and HO2 can be made in the remote free troposphere with this instrument.
Teacher Attitudes toward Subject-Specific Acceleration: Instrument Development and Validation
ERIC Educational Resources Information Center
Rambo, Karen E.; McCoach, D. Betsy
2012-01-01
Despite the research supporting acceleration, some teachers are still hesitant to recommend acceleration for advanced students. The Teacher Attitudes Toward Subject-Specific Acceleration (TATSSA) instrument was designed to uncover the factors that influence teacher decisions to recommend students for subject-specific acceleration. First, we…
Material selection indices for design of surgical instruments with long tubular shafts.
Nelson, Carl A
2013-02-01
In any medical device design process, material selection plays an important role. For devices which sustain mechanical loading, strength and stiffness requirements can be significant drivers of the design. This paper examines the specific case of minimally invasive surgical instruments, including robotic instruments, having long, tubular shafts. Material properties-based selection indices are derived for achieving high performance of these devices in terms of strength and stiffness, and the use of these indices for informing the medical device design problem is illustrated.
NASA Astrophysics Data System (ADS)
Fransen, S.; Yamawaki, T.; Akagi, H.; Eggens, M.; van Baren, C.
2014-06-01
After a first estimation based on statistics, the design loads for instruments are generally estimated by coupled spacecraft/instrument sine analysis once an FE-model of the spacecraft is available. When the design loads for the instrument have been derived, the next step in the process is to estimate the random vibration environment at the instrument base and to compute the RMS load at the centre of gravity of the instrument by means of vibro-acoustic analysis. Finally the design loads of the light-weight sub-units of the instrument can be estimated through random vibration analysis at instrument level, taking into account the notches required to protect the instrument interfaces in the hard- mounted random vibration test. This paper presents the aforementioned steps of instrument and sub-units loads derivation in the preliminary design phase of the spacecraft and identifies the problems that may be encountered in terms of design load consistency between low-frequency and high-frequency environments. The SpicA FAR-infrared Instrument (SAFARI) which is currently developed for the Space Infrared Telescope for Cosmology and Astrophysics (SPICA) will be used as a guiding example.
Combined raman spectrometer/laser-induced breakdown spectrometer design concept
NASA Astrophysics Data System (ADS)
Bazalgette Courrèges-Lacoste, Gregory; Ahlers, Berit; Boslooper, Erik; Rull-Perez, Fernando; Maurice, Sylvestre
2017-11-01
Amongst the different instruments that have been preselected to be on-board the Pasteur payload on ExoMars is the Raman/ Laser Induced Breakdown Spectroscopy (LIBS) instrument. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities. An international team under the lead of TNO has been gathered to produce a design concept for a combined Raman Spectrometer/ LIBS Elegant Bread-Board (EBB). The instrument is based on a specifically designed extremely compact spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. Low mass, size and resources are the main drivers of the instrument's design concept. The proposed design concept, realization and testing programme for the combined Raman/ LIBS EBB is presented as well as background information on Raman and LIBS.
Design package for instrumentation of the Decade 80 house in Tucson, Arizona
NASA Technical Reports Server (NTRS)
1978-01-01
A design package covering instrumentation and system design for the Decade 80 House in Tucson, Arizona is presented. The solar house is instrumented for the purpose of gathering data to determine the solar heating and cooling system performance. The use of copper in the construction of the house is a first choice construction material because it conducts heat and resists corrosion better than other materials and therefore provides a more efficient and economical system. Equipment and site specifications are reported, along with floor plans showing the location of the site instrumentation hardware.
Application of type synthesis theory to the redesign of a complex surgical instrument.
Lim, Jonas J B; Erdman, Arthur G
2002-06-01
Surgical instruments consist of basic mechanical components such as gears, links, pivots, sliders, etc., which are common in mechanical design. This paper describes the application of a method in the analysis and design of complex surgical instruments such as those employed in laparoscopic surgery. This is believed to be the first application of type synthesis theory to a complex medical instrument. Type synthesis is a methodology that can be applied during the conceptual phase of mechanical design. A handle assembly from a patented laparoscopic surgical stapler is used to illustrate the application of the design method developed. Type synthesis is applied on specific subsystems of the mechanism within the handle assembly where alternative design concepts are generated. Chosen concepts are then combined to form a new conceptual design for the handle assembly. The new handle assembly is improved because it has fewer number of parts, is a simpler design and is easier to assemble. Surgical instrument designers may use the methodology presented here to analyze the mechanical subsystems within complex instruments and to create new options that may offer improvements to the original design.
Designing for Instrumentalisation: Constructionist Perspectives on Instrumental Theory
ERIC Educational Resources Information Center
Kynigos, Chronis; Psycharis, Giorgos
2013-01-01
In this paper we aim to contribute to the process of networking between theoretical frames in mathematics education by means of forging connections between Constructionism and Instrumental Theory to discuss a design for instrumentalisation. We specifically focus on instrumentalisation, i.e. the ways in which students make changes to digital…
NASA Astrophysics Data System (ADS)
Antony, Joby; Mathuria, D. S.; Chaudhary, Anup; Datta, T. S.; Maity, T.
2017-02-01
Cryogenic network for linear accelerator operations demand a large number of Cryogenic sensors, associated instruments and other control-instrumentation to measure, monitor and control different cryogenic parameters remotely. Here we describe an alternate approach of six types of newly designed integrated intelligent cryogenic instruments called device-servers which has the complete circuitry for various sensor-front-end analog instrumentation and the common digital back-end http-server built together, to make crateless PLC-free model of controls and data acquisition. These identified instruments each sensor-specific viz. LHe server, LN2 Server, Control output server, Pressure server, Vacuum server and Temperature server are completely deployed over LAN for the cryogenic operations of IUAC linac (Inter University Accelerator Centre linear Accelerator), New Delhi. This indigenous design gives certain salient features like global connectivity, low cost due to crateless model, easy signal processing due to integrated design, less cabling and device-interconnectivity etc.
Future states: the axioms underlying prospective, future-oriented, health planning instruments.
Koch, T
2001-02-01
Proscriptive planning exercises are critical to and generally accepted as integral to health planning at varying scales. These require specific instruments designed to predict future actions on the basis of present knowledge. At the macro-level of health economics, for example, a number of future-oriented Quality of Life Instruments (QL) are commonly employed. At the level of individual decision making, on the other hand, Advance Directives (AD's) are advanced as a means by which healthy individuals can assure their wishes will be carried out if at some future point they are incapacitated. As proscriptive tools, both instrument classes appear to share an axiomatic set whose individual parts have not been rigorously considered. This paper attempts to first identify and then consider a set of five axioms underlying future oriented health planning instruments. These axioms are then critiqued using data from a pre-test survey designed specifically to address their assumptions. Results appear to challenge the validity of the axioms underlying the proscriptive planning instruments.
Effects of electrons and protons on science instruments
NASA Technical Reports Server (NTRS)
Parker, R. H.
1972-01-01
The radiation effects on typical science instruments according to the Jupiter trapped radiation design restraint model are described, and specific aspects of the model where an improved understanding would be beneficial are suggested. The spacecraft design used is the TOPS 12L configuration. Ionization and displacement damage are considered, and damage criteria are placed on the most sensitive components. Possible protective measures are mentioned: selecting components as radiation resistant as possible, using a difference in desired and undesired signal shapes for electronic shielding, orienting and locating the component on the spacecraft for better shielding, and adding passive shields to protect specific components. Available options are listed in decreasing order of attractiveness: attempt to lower the design restraints without compromising the success of the missions, trade off experiment objectives for increased reliability, alter the trajectory, and remove sensitive instruments from the payload.
Phaeton Mast Dynamics: On-Orbit Characterization of Deployable Masts
NASA Technical Reports Server (NTRS)
Michaels, Darren J.
2011-01-01
The PMD instrument is a set of three custom-designed triaxial accelerometer systems designed specifically to detect and characterize the modal dynamics of deployable masts in orbit. The instrument was designed and built as a payload for the NuSTAR spacecraft, but it is now sponsored by the Air Force Research Laboratory's DSX project. It can detect acceleration levels from 1 micro gram to 0.12g over a frequency range of 0.1Hz to 30Hz, the results of which can support future modeling and designing of deployable mast structures for space. This paper details the hardware architecture and design, calibration test and results, and current status of the PMD instrument.
46 CFR 162.050-33 - Bilge alarm: Design specification.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., however, onboard testing in accordance with the manufacturer's operating instructions is permitted for the purposes of checking instrument drift and repeatability of the instrument reading, as well as the ability to re-zero the instrument. The accuracy of the readings must at all times remain within the limits...
ERIC Educational Resources Information Center
Rosas, Juan M.; Paredes-Olay, Maria C.; Garcia-Gutierrez, Ana; Espinosa, Juan J.; Abad, Maria J. F.
2010-01-01
Three experiments were conducted to explore the effects of different interference treatments upon outcome-specific transfer from predictive learning to instrumental responding. A computer game was designed in which participants had to defend Andalusia from navy and air-force attacks. Participants learned the relationship between two instrumental…
ERIC Educational Resources Information Center
Ryba, Nancy L.; Brodsky, Stanley L.; Shlosberg, Amy
2007-01-01
Minimal information is available regarding the frequency with which practitioners conduct evaluations of capacity to waive Miranda rights or what approaches they use in doing so. Grisso's Instruments for Assessing Understanding and Appreciation of Miranda Rights are the only published instruments designed specifically to assist practitioners in…
Development of the Counseling Center Assessment of Psychological Symptoms-62 (CCAPS-62)
ERIC Educational Resources Information Center
Locke, Benjamin D.; Buzolitz, Johanna Soet; Lei, Pui-Wa; Boswell, James F.; McAleavey, Andrew A.; Sevig, Todd D.; Dowis, Jerome D.; Hayes, Jeffrey A.
2011-01-01
Few instruments have been designed specifically to address the needs of college counseling centers. This article reviews existing instruments and presents 4 studies that describe the development and psychometric properties of a new instrument, the Counseling Center Assessment of Psychological Symptoms-62 (CCAPS-62). Study 1 describes the initial…
Key issues in the thermal design of spaceborne cryogenic infrared instruments
NASA Astrophysics Data System (ADS)
Schember, Helene R.; Rapp, Donald
1992-12-01
Thermal design and analysis play an integral role in the development of spaceborne cryogenic infrared (IR) instruments. From conceptual sketches to final testing, both direct and derived thermal requirements place significant constraints on the instrument design. Although in practice these thermal requirements are interdependent, the sources of most thermal constraints may be grouped into six distinct categories. These are: (1) Detector temperatures, (2) Optics temperatures, (3) Pointing or alignment stability, (4) Mission lifetime, (5) Orbit, and (6) Test and Integration. In this paper, we discuss these six sources of thermal requirements with particular regard to development of instrument packages for low background infrared astronomical observatories. In the end, the thermal performance of these instruments must meet a set of thermal requirements. The development of these requirements is typically an ongoing and interactive process, however, and the thermal design must maintain flexibility and robustness throughout the process. The thermal (or cryogenic) engineer must understand the constraints imposed by the science requirements, the specific hardware, the observing environment, the mission design, and the testing program. By balancing these often competing factors, the system-oriented thermal engineer can work together with the experiment team to produce an effective overall design of the instrument.
ERIC Educational Resources Information Center
Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores
2009-01-01
Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…
MODIS Information, Data, and Control System (MIDACS) system specifications and conceptual design
NASA Technical Reports Server (NTRS)
Han, D.; Salomonson, V.; Ormsby, J.; Ardanuy, P.; Mckay, A.; Hoyt, D.; Jaffin, S.; Vallette, B.; Sharts, B.; Folta, D.
1988-01-01
The MODIS Information, Data, and Control System (MIDACS) Specifications and Conceptual Design Document discusses system level requirements, the overall operating environment in which requirements must be met, and a breakdown of MIDACS into component subsystems, which include the Instrument Support Terminal, the Instrument Control Center, the Team Member Computing Facility, the Central Data Handling Facility, and the Data Archive and Distribution System. The specifications include sizing estimates for the processing and storage capacities of each data system element, as well as traffic analyses of data flows between the elements internally, and also externally across the data system interfaces. The specifications for the data system, as well as for the individual planning and scheduling, control and monitoring, data acquisition and processing, calibration and validation, and data archive and distribution components, do not yet fully specify the data system in the complete manner needed to achieve the scientific objectives of the MODIS instruments and science teams. The teams have not yet been formed; however, it was possible to develop the specifications and conceptual design based on the present concept of EosDIS, the Level-1 and Level-2 Functional Requirements Documents, the Operations Concept, and through interviews and meetings with key members of the scientific community.
NASA Technical Reports Server (NTRS)
Horan, Stephen; Wang, Ru-Hai
1999-01-01
There exists a need for designers and developers to have a method to conveniently test a variety of communications parameters for an overall system design. This is no different when testing network protocols as when testing modulation formats. In this report, we discuss a means of providing a networking test device specifically designed to be used for space communications. This test device is a PC-based Virtual Instrument (VI) programmed using the LabVIEW(TM) version 5 software suite developed by National Instruments(TM)TM. This instrument was designed to be portable and usable by others without special, additional equipment. The programming was designed to replicate a VME-based hardware module developed earlier at New Mexico State University (NMSU) and to provide expanded capabilities exceeding the baseline configuration existing in that module. This report describes the design goals for the VI module in the next section and follows that with a description of the design of the VI instrument. This is followed with a description of the validation tests run on the VI. An application of the error-generating VI to networking protocols is then given.
The artificial satellite observation chronograph controlled by single chip microcomputer.
NASA Astrophysics Data System (ADS)
Pan, Guangrong; Tan, Jufan; Ding, Yuanjun
1991-06-01
The instrument specifications, hardware structure, software design, and other characteristics of the chronograph mounting on a theodolite used for artificial satellite observation are presented. The instrument is a real time control system with a single chip microcomputer.
Conceptual design studies of control and instrumentation systems for ignition experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicholson, P.J.; Dewolf, J.B.; Heinemann, P.C.
1978-03-01
Studies at the Charles Stark Draper Laboratory in the past year were a continuation of prior studies of control and instrumentation systems for current and next generation Tokomaks. Specifically, the FY 77 effort has focused on the following two main efforts: (1) control requirements--(a) defining and evolving control requirements/concepts for a prototype experimental power reactor(s), and (b) defining control requirements for diverters and mirror machines, specifically the MX; and (2) defining requirements and scoping design for a functional control simulator. Later in the year, a small additional task was added: (3) providing analysis and design support to INESCO for itsmore » low cost fusion power system, FPC/DMT.« less
Gräske, Johannes; Fischer, Thomas; Kuhlmey, Adelheid; Wolf-Ostermann, Karin
2012-01-01
Shared-housing arrangements (SHA) in Germany are a specific type of housing arrangement that belongs to the global concept of small-scale living arrangements. This caring approach comprises characteristics of both home and institutional care for persons with dementia. To evaluate the impact of SHA on the quality of life (QoL) of residents, an appropriate setting- and dementia-specific QoL instrument is needed. This article aims to identify QoL instruments that relate to the core domains of SHA. After a comprehensive literature review, existing dementia-specific QoL instruments were evaluated to determine whether any have been specifically designed for or applied in SHA. Additionally, each domain of the instruments was matched with the core domains of SHA. None of the existing instruments was identified as having been developed for SHA. Matching of the instrument domains with the SHA core domains leads to the conclusion that Quality of Life-Alzheimer's Disease, Dementia Quality of Life, Alzheimer Disease-Related Quality of Life, and QUALIDEM are adequate instruments for measuring the dementia-specific QoL of persons living in SHA. For the first time, a basis has been created for valid QoL evaluations of residents with dementia living in SHA. The 4 identified instruments are considered applicable in SHA. Conducting a performance test and evaluating further attributes according to the Scientific Advisory Committee of the Medical Outcomes Trust (e.g., reliability and validity) will further elucidation of the appropriateness of the instruments for SHA. Copyright © 2012 Mosby, Inc. All rights reserved.
Precision mechanisms for optics in a vacuum cryogenic environment
NASA Astrophysics Data System (ADS)
Navarro, R.; Elswijk, E.; Tromp, N.; Kragt, J.; Kroes, G.; Hanenburg, H.; de Haan, M.; Schuil, M.; Teuwen, M.; Janssen, H.; Venema, L.
2017-11-01
To achieve superb stability in cryogenic optical systems, NOVA-ASTRON generally designs optical instruments on the basis of a 'no adjustments' philosophy. This means that in principle no corrections are possible after assembly. The alignment precision and consequently the performance of the instrument is guaranteed from the design, the tolerance analysis and the detailed knowledge of the material behavior and manufacturing process. This resulted in a higher degree of integrated optomechanical-cryogenic design with fewer parts, but with a higher part complexity. The 'no adjustments' strategy is successful because in the end the risk on instrument performance and project delays is much reduced. Astronomical instrument specifications have become more challenging over the years. Recent designs of the European Southern Observatory Very Large Telescope Interferometer (ESO VLTI) 4 Telescope combiner MATISSE include hundreds of optical components in a cryogenic environment. Despite the large number of optical components the alignment accuracy and stability requirements are in the order of nanometers. The 'no adjustments' philosophy would be too costly in this case, because all components would need to meet extremely tight manufacturing specifications. These specifications can be relaxed dramatically if cryogenic mechanisms are used for alignment. Several mechanisms have been developed: a tip-tilt mirror mechanism, an optical path distance mechanism, a slider mechanism, a bistable cryogenic shutter and a mirror mounting clip. Key aspects of these mechanisms are that the optical element and mechanism are combined in a compact single component, driven by e.g. self braking piezo actuators in order to hold position without power. The design, realization and test results of several mechanisms are presented in this paper.
NASA Technical Reports Server (NTRS)
1974-01-01
The performance, design, and quality assurance requirements for the Earth Observatory Satellite (EOS) Observatory and Ground System program elements required to perform the Land Resources Management (LRM) A-type mission are presented. The requirements for the Observatory element with the exception of the instruments specifications are contained in the first part.
Practical Design Guidelines for Fugitive Gas Detection from Unmanned Aerial Vehicles
NASA Astrophysics Data System (ADS)
Tandy, William D., Jr.
Simulation, design, and analysis are combined in this effort to realize a UAV-scale instrument for fugitive gas detection. The contributing material to the industry begins by extending and correlating an integrated Gaussian plume model useful for instrument predictions and trade studies, regardless of the instrument type or molecule of interest. A variety of generally applicable plots are produced from this foundation, including receiver operator curves for leak rate detectability vs. wind speed, beam diameter vs. leak rate detectability, and plots for required scan densities. The atmospheric and instrument parameter trade studies are followed by hardware-specific analyses applicable to differential absorption lidar (DIAL) instruments. A synopsis of the lessons learned from hands-on experiences in the lab further define the design space for DIAL sensors. The dissertation culminates in the detailed design and analysis of two DIAL instrument concepts. The conclusion is that a DIAL instrument capable of reliably detecting a 50 SCFH plume in winds speeds up to 7 mph is on the threshold of being achievable on a quadcopter platform. Of special note is that the effort was funded by a Pipeline and Hazardous Materials Safety Administration grant and performed in collaboration with Ball Aerospace & Technologies.
Satellite-instrument system engineering best practices and lessons
NASA Astrophysics Data System (ADS)
Schueler, Carl F.
2009-08-01
This paper focuses on system engineering development issues driving satellite remote sensing instrumentation cost and schedule. A key best practice is early assessment of mission and instrumentation requirements priorities driving performance trades among major instrumentation measurements: Radiometry, spatial field of view and image quality, and spectral performance. Key lessons include attention to technology availability and applicability to prioritized requirements, care in applying heritage, approaching fixed-price and cost-plus contracts with appropriate attention to risk, and assessing design options with attention to customer preference as well as design performance, and development cost and schedule. A key element of success either in contract competition or execution is team experience. Perhaps the most crucial aspect of success, however, is thorough requirements analysis and flowdown to specifications driving design performance with sufficient parameter margin to allow for mistakes or oversights - the province of system engineering from design inception to development, test and delivery.
Design of Mechanisms for Deployable, Optical Instruments: Guidelines for Reducing Hysteresis
NASA Technical Reports Server (NTRS)
Lake, Mark S.; Hachkowski, M. Roman
2000-01-01
This paper is intended to facilitate the development of deployable, optical instruments by providing a rational approach for the design, testing, and qualification of high-precision (i.e., low-hysteresis) deployment mechanisms for these instruments. Many of the guidelines included herein come directly from the field of optomechanical engineering, and are, therefore, neither newly developed guidelines, nor are they uniquely applicable to the design of high-precision deployment mechanisms. This paper is to be regarded as a guide to design and not a set of NASA requirements, except as may be defined in formal project specifications. Furthermore, due to the rapid pace of advancement in the field of precision deployment, this paper should be regarded as a preliminary set of guidelines. However, it is expected that this paper, with revisions as experience may indicate to be desirable, might eventually form the basis for a set of uniform design requirements for high-precision deployment mechanisms on future NASA space-based science instruments.
NASA Astrophysics Data System (ADS)
Pascal, Véronique; Buil, Christian; Cansot, Elodie; Loesel, Jacques; Tauziede, Laurie; Pierangelo, Clémence; Bermudo, François
2017-11-01
Measuring the concentration of greenhouse gases from space is a current challenge. This measurement is achieved via a precise analysis of the signature of chemical gaseous species (CO2, CH4, CO, etc.) in the spectrum of the reflected sunlight. First at all, two families of spectrometers have been studied for the MicroCarb mission. The first family is based on the phenomena of interference between two radiation waves (Michelson Interferometer). The second family is based on the use of dispersive optical components. The second family has been selected for the forthcoming studies in the MicroCarb project. These instruments must have high radiometric and spectral resolutions, in narrow spectral bands, in order to discriminate between absorption lines from various atmospheric chemical species, and to quantify their concentration. This is the case, for example, for the instrument onboard the OCO-2 satellite (NASA/JPL). Our analysis has led us to define a new instrumental concept, based on a dispersive grating spectrometer, with the aim of providing the same accuracy level as the OCO-2, but with a more compact design for accommodation on the Myriade Evolution microsatellite class. This compact design approach will allow us to offer a moderate-cost solution to fulfil mission objectives. Two other studies based on dispersive grating are in progress by CNES prime contractors (ASTRIUM and THALES ALENIA SPACE). A summary of the main specifications of this design will be described, in particular the approach with the so-called "merit function". After a description of such a space instrument, which uses a specific grating component, a preliminary assessment of performances will be presented, including the theoretical calculations and formula. A breadboard implementation of this specific grating has allowed us to show the practicality of this concept and its capabilities. Some results of this breadboard will be described. In addition, an instrument simulator is being developed to validate the performances of this concept. A grating component prototype has been built, and the specifications, together with the expected performances, will be described, in particular the polarisation ratio. Some elements about detectors will be also given regarding their suitability for the mission. This preliminary design is encouraging and shows that such a spectrometer may be compatible with a microsatellite platform (low mass, low power and compact design). Some prospects of improvements will also be considered.
Design and Development of "The Reading Biographer": An Application of Function Specific Assessment.
ERIC Educational Resources Information Center
Hanson, Ralph A.; Siegel, Donna Farrell
The general features of function-specific assessment are described and illustrated via a discussion of the design and development of "The Reading Biographer," an instrument for assessing experiences and activities of students (from early childhood through high school) that affect their reading achievement as high school seniors. The…
Aerodynamic and Aerothermal TPS Instrumentation Reference Guide
NASA Technical Reports Server (NTRS)
Woollard, Bryce A.; Braun, Robert D.; Bose, Deepack
2016-01-01
The hypersonic regime of planetary entry combines the most severe environments that an entry vehicle will encounter with the greatest amount of uncertainty as to the events unfolding during that time period. This combination generally leads to conservatism in the design of an entry vehicle, specifically that of the thermal protection system (TPS). Each planetary entry provides a valuable aerodynamic and aerothermal testing opportunity; the utilization of this opportunity is paramount in better understanding how a specific entry vehicle responds to the demands of the hypersonic entry environment. Previous efforts have been made to instrument entry vehicles in order to collect data during the entry period and reconstruct the corresponding vehicle response. The purpose of this paper is to cumulatively document past TPS instrumentation designs for applicable planetary missions, as well as to list pertinent results and any explainable shortcomings.
LiteBIRD: mission overview and design tradeoffs
NASA Astrophysics Data System (ADS)
Matsumura, T.; Akiba, Y.; Borrill, J.; Chinone, Y.; Dobbs, M.; Fuke, H.; Hasegawa, M.; Hattori, K.; Hattori, M.; Hazumi, M.; Holzapfel, W.; Hori, Y.; Inatani, J.; Inoue, M.; Inoue, Y.; Ishidoshiro, K.; Ishino, H.; Ishitsuka, H.; Karatsu, K.; Kashima, S.; Katayama, N.; Kawano, I.; Kibayashi, A.; Kibe, Y.; Kimura, K.; Kimura, N.; Komatsu, E.; Kozu, M.; Koga, K.; Lee, A.; Matsuhara, H.; Mima, S.; Mitsuda, K.; Mizukami, K.; Morii, H.; Morishima, T.; Nagai, M.; Nagata, R.; Nakamura, S.; Naruse, M.; Namikawa, T.; Natsume, K.; Nishibori, T.; Nishijo, K.; Nishino, H.; Noda, A.; Noguchi, T.; Ogawa, H.; Oguri, S.; Ohta, I. S.; Okada, N.; Otani, C.; Richards, P.; Sakai, S.; Sato, N.; Sato, Y.; Segawa, Y.; Sekimoto, Y.; Shinozaki, K.; Sugita, H.; Suzuki, A.; Suzuki, T.; Tajima, O.; Takada, S.; Takakura, S.; Takei, Y.; Tomaru, T.; Uzawa, Y.; Wada, T.; Watanabe, H.; Yamada, Y.; Yamaguchi, H.; Yamasaki, N.; Yoshida, M.; Yoshida, T.; Yotsumoto, K.
2014-08-01
We present the mission design of LiteBIRD, a next generation satellite for the study of B-mode polarization and inflation from cosmic microwave background radiation (CMB) detection. The science goal of LiteBIRD is to measure the CMB polarization with the sensitivity of δr = 0:001, and this allows testing the major single-field slow-roll inflation models experimentally. The LiteBIRD instrumental design is purely driven to achieve this goal. At the earlier stage of the mission design, several key instrumental specifications, e.g. observing band, optical system, scan strategy, and orbit, need to be defined in order to process the rest of the detailed design. We have gone through the feasibility studies for these items in order to understand the tradeoffs between the requirements from the science goal and the compatibilities with a satellite bus system. We describe the overview of LiteBIRD and discuss the tradeoffs among the choices of scientific instrumental specifications and strategies. The first round of feasibility studies will be completed by the end of year 2014 to be ready for the mission definition review and the target launch date is in early 2020s.
Key Parameters for Operator Diagnosis of BWR Plant Condition during a Severe Accident
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clayton, Dwight A.; Poore, III, Willis P.
2015-01-01
The objective of this research is to examine the key information needed from nuclear power plant instrumentation to guide severe accident management and mitigation for boiling water reactor (BWR) designs (specifically, a BWR/4-Mark I), estimate environmental conditions that the instrumentation will experience during a severe accident, and identify potential gaps in existing instrumentation that may require further research and development. This report notes the key parameters that instrumentation needs to measure to help operators respond to severe accidents. A follow-up report will assess severe accident environmental conditions as estimated by severe accident simulation model analysis for a specific US BWR/4-Markmore » I plant for those instrumentation systems considered most important for accident management purposes.« less
Strong Motion Instrumentation of Seismically-Strengthened Port Structures in California by CSMIP
Huang, M.J.; Shakal, A.F.
2009-01-01
The California Strong Motion Instrumentation Program (CSMIP) has instrumented five port structures. Instrumentation of two more port structures is underway and another one is in planning. Two of the port structures have been seismically strengthened. The primary goals of the strong motion instrumentation are to obtain strong earthquake shaking data for verifying seismic analysis procedures and strengthening schemes, and for post-earthquake evaluations of port structures. The wharves instrumented by CSMIP were recommended by the Strong Motion Instrumentation Advisory Committee, a committee of the California Seismic Safety Commission. Extensive instrumentation of a wharf is difficult and would be impossible without the cooperation of the owners and the involvement of the design engineers. The instrumentation plan for a wharf is developed through study of the retrofit plans of the wharf, and the strong-motion sensors are installed at locations where specific instrumentation objectives can be achieved and access is possible. Some sensor locations have to be planned during design; otherwise they are not possible to install after construction. This paper summarizes the two seismically-strengthened wharves and discusses the instrumentation schemes and objectives. ?? 2009 ASCE.
Research pressure instrumentation for NASA Space Shuttle main engine, modification no. 5
NASA Technical Reports Server (NTRS)
Anderson, P. J.; Nussbaum, P.; Gustafson, G.
1984-01-01
Research concerning the development of pressure instrumentation for the space shuttle main engine is reported. The following specific topics were addressed: (1) transducer design and materials, (2) silicon piezoresistor characterization at cryogenic temperatures, (3) chip mounting characterization, and (4) frequency response optimization.
2017-03-03
biomechanical gait state changes within prolonged exercise or training events. II. MATERIAL AND METHODS A. Instrumented Insert Design We developed a...beginning and end of each data collection trial using a user interface designed specifically for this purpose in MATLAB. F. Calibration Proces:Static...consisted of walking for several minutes indoors (thin carpeted surface on concrete) and outdoors on several different surfaces ( pavement , gravel and
Development of a near-infrared spectroscopy instrument for applications in urology.
Macnab, Andrew J; Stothers, Lynn
2008-10-01
Near infrared spectroscopy (NIRS) is an established technology using photons of light in the near infrared spectrum to monitor changes in tissue of naturally occurring chromophores, including oxygenated and deoxygenated hemoglobin. Technology and methodology have been validated for measurement of a range of physiologic parameters. NIRS has been applied successfully in urology research; however current instruments are designed principally for brain and muscle study. To describe development of a NIRS instrument specifically designed for monitoring changes in chromophore concentration in the bladder detrusor in real time, to facilitate research to establish the role of this non-invasive technology in the evaluation of patients with voiding dysfunction The portable continuous wave NIRS instrument has a 3 laser diode light source (785, 808 and 830 nanometers), fiber optic cables for light transmission, a self adhesive patient interface patch with an emitter and sensor, and software to detect the difference between the light transmitted and received by the instrument. Software incorporated auto-attenuates the optical signals and converts raw optical data into chromophore concentrations displayed graphically. The prototype was designed, tested, and iteratively developed to achieve optimal suprapubic transcutaneous monitoring of the detrusor in human subjects during bladder filling and emptying. Evaluation with simultaneous invasive urodynamic measurement in men and women indicates good specificity and sensitivity of NIRS chromophore concentration changes by receiver operator curve analysis, and correlation between NIRS data and urodynamic pressures. Urological monitoring with this NIRS instrument is feasible and generates data of potential diagnostic value.
Sjoding, Michael W; Schoenfeld, David A; Brown, Samuel M; Hough, Catherine L; Yealy, Donald M; Moss, Marc; Angus, Derek C; Iwashyna, Theodore J
2017-01-01
After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT's power to measure significant differences in these outcomes is poorly understood. Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. We derived a general formula and Stata code for calculating an RCT's power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress-like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT ( www.clinicaltrials.gov identifier NCT02509078). On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Examining instruments' power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities.
NASA Astrophysics Data System (ADS)
Zemcov, M.; Arai, T.; Battle, J.; Bock, J.; Cooray, A.; Hristov, V.; Keating, B.; Kim, M. G.; Lee, D. H.; Levenson, L. R.; Mason, P.; Matsumoto, T.; Matsuura, S.; Nam, U. W.; Renbarger, T.; Sullivan, I.; Suzuki, K.; Tsumura, K.; Wada, T.
2013-08-01
The Cosmic Infrared Background Experiment (CIBER) is a suite of four instruments designed to study the near infrared (IR) background light from above the Earth's atmosphere. The instrument package comprises two imaging telescopes designed to characterize spatial anisotropy in the extragalactic IR background caused by cosmological structure during the epoch of reionization, a low resolution spectrometer to measure the absolute spectrum of the extragalactic IR background, and a narrow band spectrometer optimized to measure the absolute brightness of the zodiacal light foreground. In this paper we describe the design and characterization of the CIBER payload. The detailed mechanical, cryogenic, and electrical design of the system are presented, including all system components common to the four instruments. We present the methods and equipment used to characterize the instruments before and after flight, and give a detailed description of CIBER's flight profile and configurations. CIBER is designed to be recoverable and has flown four times, with modifications to the payload having been informed by analysis of the first flight data. All four instruments performed to specifications during the subsequent flights, and the scientific data from these flights are currently being analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zemcov, M.; Bock, J.; Hristov, V.
2013-08-15
The Cosmic Infrared Background Experiment (CIBER) is a suite of four instruments designed to study the near infrared (IR) background light from above the Earth's atmosphere. The instrument package comprises two imaging telescopes designed to characterize spatial anisotropy in the extragalactic IR background caused by cosmological structure during the epoch of reionization, a low resolution spectrometer to measure the absolute spectrum of the extragalactic IR background, and a narrow band spectrometer optimized to measure the absolute brightness of the zodiacal light foreground. In this paper we describe the design and characterization of the CIBER payload. The detailed mechanical, cryogenic, andmore » electrical design of the system are presented, including all system components common to the four instruments. We present the methods and equipment used to characterize the instruments before and after flight, and give a detailed description of CIBER's flight profile and configurations. CIBER is designed to be recoverable and has flown four times, with modifications to the payload having been informed by analysis of the first flight data. All four instruments performed to specifications during the subsequent flights, and the scientific data from these flights are currently being analyzed.« less
Friction characteristics of trocars in laparoscopic surgery.
Alazmani, Ali; Roshan, Rupesh; Jayne, David G; Neville, Anne; Culmer, Peter
2015-04-01
This article investigates the friction characteristics of the instrument-trocar interface in laparoscopic surgery for varying linear instrument velocities, trocar seal design and material, and trocar tilt. Furthermore, the effect of applying lubrication at the instrument-trocar seal interface on friction was studied. A friction testing apparatus was designed and built to characterise the resistance force at the instrument-trocar interface as a function of the instrument's linear movement in the 12-mm trocar (at constant velocity) for different design, seal material, and angle of tilt. The resistance force depended on the trocar seal design and material properties, specifically surface roughness, elasticity, hardness, the direction of movement, and the instrument linear velocity, and varied between 0.25 and 8 N. Lubricating the shaft with silicone oil reduced the peak resistance force by 75% for all trocars and eliminated the stick-slip phenomenon evident in non-lubricated cases. The magnitude of fluctuation in resistance force depends on the trocar design and is attributed to stick-slip of the sealing mechanism and is generally higher during retraction in comparison to insertion. Trocars that have an inlet seal made of rubber/polyurethane showed higher resistance forces during retraction. Use of a lubricant significantly reduced frictional effects. Comparisons of the investigated trocars indicate that a low friction port, providing the surgeon with improved haptic feedback, can be designed by improving the tribological properties of the trocar seal interface. © IMechE 2015.
ROSAT implementation of a proposed multi-mission x ray data format
NASA Technical Reports Server (NTRS)
Corcoran, M.; Pence, W.; White, R.; Conroy, M.
1992-01-01
Until recently little effort has been made to ensure that data from X-ray telescopes are delivered in a format that reflects the common characteristics that most X-ray datasets share. Instrument-specific data-product design hampers the comparison of X-ray measurements made by different detectors and should be avoided whenever possible. The ROSAT project and the High Energy Astrophysics Science Archive Research Center (HEASARC) have defined a set of X-ray data products ('rationalized files') for ROSAT data that can be used for distribution and archiving of data from other X-ray missions. This set of 'rationalized files' has been defined to isolate instrument-independent and instrument-specific quantities using standards FITS constructs to ensure portability. We discuss the usage of the 'rationalized files' by ROSAT for data distribution and archiving, with particular emphasis on discrimination between instrument-independent and instrument-specific quantities, and discuss application of this format to data from other X-ray missions.
Active and Collaborative Learning in an Introductory Electrical and Computer Engineering Course
ERIC Educational Resources Information Center
Kotru, Sushma; Burkett, Susan L.; Jackson, David Jeff
2010-01-01
Active and collaborative learning instruments were introduced into an introductory electrical and computer engineering course. These instruments were designed to assess specific learning objectives and program outcomes. Results show that students developed an understanding comparable to that of more advanced students assessed later in the…
ALSEP arrays A, B, C, and A-2. [lunar surface exploration instrument specifications
NASA Technical Reports Server (NTRS)
1973-01-01
The objectives of the lunar surface exploration packages are defined and the preliminary design of scientific systems hardware is reported. Instrument packages are to collect and transmit to earth scientific data on the lunar interior, the lunar surface composition, and the lunar geomorphology
NASA Astrophysics Data System (ADS)
Thyagarajan, Nithyanandan
2018-05-01
Direct detection of the Epoch of Reionization (EoR) via redshifted 21 cm line of H i will reveal the nature of the first stars and galaxies as well as revolutionize our understanding of a poorly explored evolutionary phase of the Universe. Projects such as the MWA, LOFAR, and PAPER commenced in the last decade with the promise of high significance statistical detection of the EoR, but have so far only weakly constrained models owing to unforeseen challenges from bright foreground sources and instrument systematics. It is essential for next generation instruments like the HERA and SKA to have these challenges addressed. I present an analysis of these challenges - wide-field measurements, antenna beam chromaticity, reflections in the instrument, and antenna position errors - along with performance specifications and design solutions that will be critical to designing successful next-generation instruments in enabling the first detection and also in placing meaningful constraints on reionization models.
Design and implementation of the mobility assessment tool: software description.
Barnard, Ryan T; Marsh, Anthony P; Rejeski, Walter Jack; Pecorella, Anthony; Ip, Edward H
2013-07-23
In previous work, we described the development of an 81-item video-animated tool for assessing mobility. In response to criticism levied during a pilot study of this tool, we sought to develop a new version built upon a flexible framework for designing and administering the instrument. Rather than constructing a self-contained software application with a hard-coded instrument, we designed an XML schema capable of describing a variety of psychometric instruments. The new version of our video-animated assessment tool was then defined fully within the context of a compliant XML document. Two software applications--one built in Java, the other in Objective-C for the Apple iPad--were then built that could present the instrument described in the XML document and collect participants' responses. Separating the instrument's definition from the software application implementing it allowed for rapid iteration and easy, reliable definition of variations. Defining instruments in a software-independent XML document simplifies the process of defining instruments and variations and allows a single instrument to be deployed on as many platforms as there are software applications capable of interpreting the instrument, thereby broadening the potential target audience for the instrument. Continued work will be done to further specify and refine this type of instrument specification with a focus on spurring adoption by researchers in gerontology and geriatric medicine.
Instrument Selection for Randomized Controlled Trials Why This and Not That?
Records, Kathie; Keller, Colleen; Ainsworth, Barbara; Permana, Paska
2011-01-01
A fundamental linchpin for obtaining rigorous findings in quantitative research involves the selection of survey instruments. Psychometric recommendations are available for the processes for scale development and testing and guidance for selection of established scales. These processes are necessary to address the validity link between the phenomena under investigation, the empirical measures and, ultimately, the theoretical ties between these and the world views of the participants. Detailed information is most often provided about study design and protocols, but far less frequently is a detailed theoretical explanation provided for why specific instruments are chosen. Guidance to inform choices is often difficult to find when scales are needed for specific cultural, ethnic, or racial groups. This paper details the rationale underlying instrument selection for measurement of the major processes (intervention, mediator and moderator variables, outcome variables) in an ongoing study of postpartum Latinas, Madres para la Salud [Mothers for Health]. The rationale underpinning our choices includes a discussion of alternatives, when appropriate. These exemplars may provide direction for other intervention researchers who are working with specific cultural, racial, or ethnic groups or for other investigators who are seeking to select the ‘best’ instrument. Thoughtful consideration of measurement and articulation of the rationale underlying our choices facilitates the maintenance of rigor within the study design and improves our ability to assess study outcomes. PMID:21986392
Ng, Vincent Y; DeClaire, Jeffrey H; Berend, Keith R; Gulick, Bethany C; Lombardi, Adolph V
2012-01-01
Coronal malalignment occurs frequently in TKA and may affect implant durability and knee function. Designed to improve alignment accuracy and precision, the patient-specific positioning guide is predicated on restoration of the overall mechanical axis and is a multifaceted new tool in achieving traditional goals of TKA. We compared the effectiveness of patient-specific positioning guides to manual instrumentation with intramedullary femoral and extramedullary tibial guides in restoring the mechanical axis of the extremity and achieving neutral coronal alignment of the femoral and tibial components. We retrospectively reviewed 569 TKAs performed with patient-specific positioning guides and 155 with manual instrumentation by two surgeons using postoperative long-leg radiographs. For all patients, we assessed the zone in which the overall mechanical axis passed through the knee, and for one surgeon's cases (105 patient-specific positioning guide, 55 manual instrumentation), we also measured the hip-knee-ankle angle and the individual component angles with respect to their mechanical axes. The overall mechanical axis passed through the central third of the knee more often with patient-specific positioning guides (88%) than with manual instrumentation (78%). The overall mean hip-knee-ankle angle for patient-specific positioning guides (180.6°) was similar to manual instrumentation (181.1°), but there were fewer ± 3° hip-knee-ankle angle outliers with patient-specific positioning guides (9%) than with manual instrumentation (22%). The overall mean tibial (89.9° versus 90.4°) and femoral (90.7° versus 91.3°) component angles were closer to neutral with patient-specific positioning guides than with manual instrumentation, but the rate of ± 2° outliers was similar for both the tibia (10% versus 7%) and femur (22% versus 18%). Patient-specific positioning guides can assist in achieving a neutral mechanical axis with reduction in outliers.
NASA Technical Reports Server (NTRS)
Saltzman, Eric S.; DeBruyn, Warren J.
2000-01-01
This project involved the design and construction of a new instrument for airborne measurement of DMS and SO2. The instrument is intended for use on field missions to study the global atmospheric sulfur cycle. The ultimate scientific goal is to provide insight into the mechanisms of atmospheric transport and transformations impacting both natural and anthropogenic sulfur emissions. This report summarizes the progress made to date and the goals for future work on the project. The PI's for this project have recently relocated from the University of Miami to the University of California, Irvine, and a request has been made to transfer remaining funds to UCI. All equipment associated with this project has been transferred to UCI. The instrument design goal was to develop an instrument roughly one quarter the size and weight of currently available airborne instrumentation used for DMS and S02 measurements. Another goal was full automation, to allow unattended operation for the duration of a P-3 or DC-8 flight. The original performance design specifications for the instrument are given.
NASA Technical Reports Server (NTRS)
Ioup, George E.; Ioup, Juliette W.
1991-01-01
The final report for work on the determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution is presented. Papers and theses prepared during the research report period are included. Among all the research results reported, note should be made of the specific investigation of the determination of design and operation parameters for upper atmospheric research instrumentation to yield optimum resolution with deconvolution. A methodology was developed to determine design and operation parameters for error minimization when deconvolution is included in data analysis. An error surface is plotted versus the signal-to-noise ratio (SNR) and all parameters of interest. Instrumental characteristics will determine a curve in this space. The SNR and parameter values which give the projection from the curve to the surface, corresponding to the smallest value for the error, are the optimum values. These values are constrained by the curve and so will not necessarily correspond to an absolute minimum in the error surface.
Spaceborne Gravity Gradiometers. Part 3: Instrument status and prospects
NASA Technical Reports Server (NTRS)
1984-01-01
Various technologies incorporated in the development of gravity gradiometers are demonstrated through descriptions of specific instruments. Concepts covered include: rotating, spherical, cryogenic, and superconducting gravity gradiometers with and without accelerometers. The application of superconducting cavity oscillators to mass-spring gradiometers, and cooperation of Italy's Piano Spaziale Nazionale with the Smithsonian Astrophysics Observatory in the design and development of a high sensitivity gradiometer are described. Schematics are provided for each instrument.
Mayo, Ann M
2015-01-01
It is important for CNSs and other APNs to consider the reliability and validity of instruments chosen for clinical practice, evidence-based practice projects, or research studies. Psychometric testing uses specific research methods to evaluate the amount of error associated with any particular instrument. Reliability estimates explain more about how well the instrument is designed, whereas validity estimates explain more about scores that are produced by the instrument. An instrument may be architecturally sound overall (reliable), but the same instrument may not be valid. For example, if a specific group does not understand certain well-constructed items, then the instrument does not produce valid scores when used with that group. Many instrument developers may conduct reliability testing only once, yet continue validity testing in different populations over many years. All CNSs should be advocating for the use of reliable instruments that produce valid results. Clinical nurse specialists may find themselves in situations where reliability and validity estimates for some instruments that are being utilized are unknown. In such cases, CNSs should engage key stakeholders to sponsor nursing researchers to pursue this most important work.
Analysis of commercial equipment and instrumentation for Spacelab payloads, volume 2
NASA Technical Reports Server (NTRS)
1974-01-01
Technical results are presented of a study to investigate analytically the feasibility of using commercially available laboratory equipment and instrumentation in the spacelab in support of various experiments. The feasibility is demonstrated by the breadth of application of commercial, airborne, and military equipment to experiment equipment requirements in the spacelab, and the cost effectiveness of utilizing this class of equipment instead of custom-built aerospace equipment typical of past designs. Equipment design and specifications are discussed.
Remote Sensing of Salinity and Overview of Results from Aquarius
NASA Technical Reports Server (NTRS)
Le Vine, D. M.; Dinnat, E. P.; Meissner, T.; Wentz, F.; Yueh, S. H.; Lagerloef, G. S. E.
2015-01-01
Aquarius is a combined active/passive microwave (L-band) instrument designed to map the salinity of global oceans from space. The specific goal of Aquarius is to monitor the seasonal and interannual variation of the large scale features of the sea surface salinity (SSS) field of the open ocean (i.e. away from land). The instrumentation has been designed to provide monthly maps with a spatial resolution of 150 km and an accuracy of 0.2 psu
Design and implementation of the mobility assessment tool: software description
2013-01-01
Background In previous work, we described the development of an 81-item video-animated tool for assessing mobility. In response to criticism levied during a pilot study of this tool, we sought to develop a new version built upon a flexible framework for designing and administering the instrument. Results Rather than constructing a self-contained software application with a hard-coded instrument, we designed an XML schema capable of describing a variety of psychometric instruments. The new version of our video-animated assessment tool was then defined fully within the context of a compliant XML document. Two software applications—one built in Java, the other in Objective-C for the Apple iPad—were then built that could present the instrument described in the XML document and collect participants’ responses. Separating the instrument’s definition from the software application implementing it allowed for rapid iteration and easy, reliable definition of variations. Conclusions Defining instruments in a software-independent XML document simplifies the process of defining instruments and variations and allows a single instrument to be deployed on as many platforms as there are software applications capable of interpreting the instrument, thereby broadening the potential target audience for the instrument. Continued work will be done to further specify and refine this type of instrument specification with a focus on spurring adoption by researchers in gerontology and geriatric medicine. PMID:23879716
Mini-Laparoscopy: Instruments and Economics.
Shadduck, Phillip P; Paquentin, Eduardo Moreno; Carvalho, Gustavo L; Redan, Jay A
2015-11-01
Mini-laparoscopy (Mini) was pioneered more than 20 years ago, initially with instruments borrowed from other specialties and subsequently with tools designed specifically for Mini. Early adoption of Mini was inhibited though by the limitations of these first-generation instruments, especially functionality and durability. Newer generation Mini instruments have recently become available with improved effector tips, a choice of shaft diameters and lengths, better shaft insulation and electrosurgery capability, improved shaft strength and rotation, more ergonomic handles, low-friction trocar options, and improved instrument durability. Improvements are also occurring in imaging and advanced energy for Mini. The current status of mini-laparoscopy instruments and economics are presented.
NASA Astrophysics Data System (ADS)
Teague, Kelly K.; Smith, G. Louis; Priestley, Kory; Lukashin, Constantine; Roithmayr, Carlos
2012-09-01
Five CERES scanning radiometers have been flown to date. The Proto-Flight Model flew aboard the Tropical Rainfall Measurement Mission spacecraft in November 1997. Two CERES instruments, Flight Models (FM) 1 and 2, are aboard the Terra spacecraft, which was launched in December 1999. Two more CERES instruments, FM-3 and FM-4, are on the Aqua spacecraft, which was placed in orbit in May 2002. These instruments continue to operate after providing over a decade of Earth Radiation Budget data. The CERES FM-5 instrument, onboard the Suomi-NPP spacecraft, launched in October 2011. The CERES FM- 6 instrument is manifested on the JPPS-1 spacecraft to be launched in December 2016. A successor to these instruments is presently in the definition stage. This paper describes the evolving role of flight software in the operation of these instruments to meet the Science objectives of the mission and also the ability to execute supplemental tasks as they evolve. In order to obtain and maintain high accuracy in the data products from these instruments, a number of operational activities have been developed and implemented since the instruments were originally designed and placed in orbit. These new activities are possible because of the ability to exploit and modify the flight software, which operates the instruments. The CERES Flight Software interface was designed to allow for on-orbit modification, and as such, constantly evolves to meet changing needs. The purpose of this paper is to provide a brief overview of modifications which have been developed to allow dedicated targeting of specific geographic locations as the CERES sensor flies overhead on its host spacecraft. This new observing strategy greatly increases the temporal and angular sampling for specific targets of high scientific interest.
Schoenfeld, David A.; Brown, Samuel M.; Hough, Catherine L.; Yealy, Donald M.; Moss, Marc; Angus, Derek C.; Iwashyna, Theodore J.
2017-01-01
Rationale: After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT’s power to measure significant differences in these outcomes is poorly understood. Objectives: Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. Methods: We derived a general formula and Stata code for calculating an RCT’s power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress–like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT (www.clinicaltrials.gov identifier NCT02509078). Measurements and Main Results: On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Conclusions: Examining instruments’ power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities. PMID:27788018
Multi-angle Imaging Spectro Radiometer (MISR) Design Issues Influened by Performance Requirements
NASA Technical Reports Server (NTRS)
Bruegge, C. J.; White, M. L.; Chrien, N. C. L.; Villegas, E. B.; Raouf, N.
1993-01-01
The design of an Earth Remote Sensing Sensor, such as the Multi-angle Imaging SpectroRadiometer (MISR), begins with a set of science requirements and is quickly followed by a set of instrument specifications.
[Valuating public health in some zoos in Colombia. Phase 1: designing and validating instruments].
Agudelo-Suárez, Angela N; Villamil-Jiménez, Luis C
2009-10-01
Designing and validating instruments for identifying public health problems in some zoological parks in Colombia, thereby allowing them to be evaluated. Four instruments were designed and validated along with the participation of five zoos. The instruments were validated regarding appearance, content, sensitivity to change, reliability tests and determining the tools' usefulness. An evaluation scale was created which assigned a maximum of 400 points, having the following evaluation intervals: 350-400 points meant good public health management, 100-349 points for regular management and 0-99 points for deficient management. The instruments were applied to the five zoos as part of the validation, forming a base-line for future evaluation of public health in them. Four valid and useful instruments were obtained for evaluating public health in zoos in Colombia. The five zoos presented regular public health management. The base-line obtained when validating the instruments led to identifying strengths and weaknesses regarding public health management in the zoos. The instruments obtained generally and specifically evaluated public health management; they led to diagnosing, identifying, quantifying and scoring zoos in Colombia in terms of public health. The base-line provided a starting point for making comparisons and enabling future follow-up of public health in Colombian zoos.
ERIC Educational Resources Information Center
Koch, D. Shane; Sneed, Zachery; Davis, Sharon J.; Benshoff, John J.
2006-01-01
Researchers in this study sought to construct an instrument specifically designed to measure counselor trainee attitudes toward alcohol and drug abuse. The instrument, the "Counselor Trainee Attitudes Measure" (CTAM), used for this research was developed collectively by the researchers. The CTAM gathered demographic data including undergraduate or…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-13
... Specifications (STS) to define a new time limit for restoring inoperable RCS leakage detection instrumentation to... contents of the facility design bases related to the operability of the RCS leakage detection... leakage detection instrumentation to operable status and establish alternate methods of monitoring RCS...
Instrumental Music Educators' Experiences in a Professional Development Course
ERIC Educational Resources Information Center
Draves, Tami J.
2017-01-01
The purpose of this research was to investigate the experiences of instrumental music teachers in Designing Arts Instruction, a 4-day professional development course in a large urban school district. Specifically, I was interested in which activities participants (a) found most relevant and applicable to their current teaching situation, (b)…
Calibrating a Measure of Gender Differences in Motivation for Learning Technology
ERIC Educational Resources Information Center
Hwang, Young Suk; Fisher, William; Vrongistinos, Konstantinos
2009-01-01
This paper reports on the theory, design, and calibration of an instrument for measuring gender difference in motivation for learning technology. The content of the instrument was developed based upon the motivational theories of Eccles and others. More specifically, the learners' self-concept of ability, perception of technology, perception of…
Complementary and Alternative Medicine Use Among US Navy and Marine Corps Personnel
2007-05-16
protection of human subjects in research (Protocol NHRC.2001.0001). Postal survey The choice of questions and question layouts for the sur- vey instrument were...specific health problems within the past 12 months. The optically scanned 10-page survey instrument was designed to take approximately 30 minutes to...suggestions, the survey instrument was refined before the initial mailing. Additionally, a random sample of 33% of individuals who completed the
A Radiation Hardened by Design CMOS ASIC for Thermopile Readouts
NASA Technical Reports Server (NTRS)
Quilligan, G.; Aslam, S.; DuMonthier, J.
2012-01-01
A radiation hardened by design (RHBD) mixed-signal application specific integrated circuit (ASIC) has been designed for a thermopile readout for operation in the harsh Jovian orbital environment. The multi-channel digitizer (MCD) ASIC includes 18 low noise amplifier channels which have tunable gain/filtering coefficients, a 16-bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The 18 channels, SDADC and controller were designed to operate with immunity to single event latchup (SEL) and to at least 10 Mrad total ionizing dose (TID). The ASIC also contains a radiation tolerant 16-bit 20 MHz Nyquist ADC for general purpose instrumentation digitizer needs. The ASIC is currently undergoing fabrication in a commercial 180 nm CMOS process. Although this ASIC was designed specifically for the harsh radiation environment of the NASA led JEO mission it is suitable for integration into instrumentation payloads 011 the ESA JUICE mission where the radiation hardness requirements are slightly less stringent.
Latch fittings for the scientific instruments on the space telescope
NASA Technical Reports Server (NTRS)
Dozier, J. D.; Kaelber, E.
1983-01-01
Latch fittings which kinematically mount the replaceable scientific instruments onto the Space Telescope must maintain precise alignment and thermal stability for on-orbit observations. Design features which are needed to meet stringent criteria include the use of ceramic isolators for thermal and electrical insulation, materials with different coefficients of thermal expansion for athermalization, precision manufacturing procedures, and extremely tight tolerances. A specific latch fitting to be discussed is a ball-and-socket design. In addition, testing, crew aids, and problems will be covered.
Identification of Critical Design Points for the EAP of a Space-based Doppler Lidar Wind Sounder
NASA Technical Reports Server (NTRS)
Emmitt, G. D.; Wood, S. A.
1992-01-01
The feasibility of making tropospheric wind measurements with a space-based Doppler lidar was studied by a number of agencies over the past 10-15 years. Currently NASA has a plan to launch such an instrument, the Laser Atmospheric Wind Sounder (LAWS), within the next decade. The design of the LAWS continues to undergo a series of iterations common to most instruments targeted for a space platform. In general, the constraints of available platform power, weight allowance, and project funds continue to change. With these changes the performance and design specifications also must change.
From SPOT 5 to Pleiades HR: evolution of the instrumental specifications
NASA Astrophysics Data System (ADS)
Rosak, A.; Latry, C.; Pascal, V.; Laubier, D.
2017-11-01
Image quality specifications should aimed to fulfil high resolution mission requirements of remote sensing satellites with a minimum cost. The most important trade-off to be taken into account is between Modulation Transfer Function, radiometric noise and sampling scheme. This compromise is the main driver during design optimisation and requirement definition in order to achieve good performances and to minimise the mission cost. For the SPOT 5 satellite, a new compromise had been chosen. The supermode principle of imagery (sampling at 2.5 meter with a pixel size of 5 meter) imp roves the resolution by a factor of four compared with the SPOT 4 satellite (10 meter resolution). This paper presents the image quality specifications of the HRG-SPOT 5 instrument. We introduce all the efforts made on the instrument to achieve good image quality and low radiometric noise, then we compare the results with the SPOT 4 instrument's performances to highlight the improvements achieved. Then, the in-orbit performance will be described. Finally, we will present the new goals of image quality specifications for the new Pleiades-HR satellite for earth observation (0.7 meter resolution) and the instrument concept.
AMBER instrument control software
NASA Astrophysics Data System (ADS)
Le Coarer, Etienne P.; Zins, Gerard; Gluck, Laurence; Duvert, Gilles; Driebe, Thomas; Ohnaka, Keiichi; Heininger, Matthias; Connot, Claus; Behrend, Jan; Dugue, Michel; Clausse, Jean Michel; Millour, Florentin
2004-09-01
AMBER (Astronomical Multiple BEam Recombiner) is a 3 aperture interferometric recombiner operating between 1 and 2.5 um, for the Very Large Telescope Interferometer (VLTI). The control software of the instrument, based on the VLT Common Software, has been written to comply with specific features of the AMBER hardware, such as the Infrared detector read out modes or piezo stage drivers, as well as with the very specific operation modes of an interferomtric instrument. In this respect, the AMBER control software was designed to insure that all operations, from the preparation of the observations to the control/command of the instrument during the observations, would be kept as simple as possible for the users and operators, opening the use of an interferometric instrument to the largest community of astronomers. Peculiar attention was given to internal checks and calibration procedures both to evaluate data quality in real time, and improve the successes of long term UV plane coverage observations.
The instrument for investigating magnetic fields of isochronous cyclotrons
NASA Astrophysics Data System (ADS)
Avreline, N. V.
2017-12-01
A new instrument was designed and implemented in order to increase the measurement accuracy of magnetic field maps for isochronous Cyclotrons manufactured by Advanced Cyclotron Systems Inc. This instrument uses the Hall Probe (HP) from New Zealand manufacturer Group3. The specific probe used is MPT-141 HP and can measure magnetic field in the range from 2G to 21kG. Use of a fast ADC NI9239 module and error reduction algorithms, based on a polynomial regression method, allowed to reduce the noise to 0.2G. The design of this instrument allows to measure high gradient magnetic fields, as the resolution of the HP arm angle is within 0.0005° and the radial position resolution is within 25μm. A set of National Instrument interfaces connected to a desktop computer through a network are used as base control and data acquisition systems.
Field measurements on skewed semi-integral bridge with elastic inclusion : instrumentation report.
DOT National Transportation Integrated Search
2006-01-01
This project was designed to enhance the Virginia Department of Transportation's expertise in the design of integral bridges, particularly as it applies to highly skewed structures. Specifically, the project involves extensive monitoring of a semi-in...
A Comprehensive Review of Sensors and Instrumentation Methods in Devices for Musical Expression
Medeiros, Carolina Brum; Wanderley, Marcelo M.
2014-01-01
Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009–2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments. PMID:25068865
A comprehensive review of sensors and instrumentation methods in devices for musical expression.
Medeiros, Carolina Brum; Wanderley, Marcelo M
2014-07-25
Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009-2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments.
Canela, Carlos; Schleifer, Roman; Dube, Anish; Hengartner, Michael P; Ebner, Gerhard; Seifritz, Erich; Liebrenz, Michael
2016-03-01
Occupational capacity evaluations have previously been subject to criticism for lacking in quality and consistency. To the authors' knowledge, there is no clear consensus on the best way to formally assess functioning within capacity evaluations. In this review we investigated different instruments that are used to assess functioning in occupational capacity evaluations. Systematic review of the literature. Though several instruments that assess functional capacity were found in our search, a specific validated instrument assessing occupational capacity as part of a larger psychiatric evaluation was not found. The limitations of the existing instruments on assessing functional capacity are discussed. Medical experts relying on instruments to conduct functional capacity evaluations should be cognizant of their limitations. The findings call for the development and use of an instrument specifically designed to assess the functional and occupational capacity of psychiatric patients, which is also likely to improve the quality of these reports. © Georg Thieme Verlag KG Stuttgart · New York.
High precision silicon piezo resistive SMART pressure sensor
NASA Astrophysics Data System (ADS)
Brown, Rod
2005-01-01
Instruments for test and calibration require a pressure sensor that is precise and stable. Market forces also dictate a move away from single measurand test equipment and, certainly in the case of pressure, away from single range equipment. A pressure `module' is required which excels in pressure measurement but is interchangble with sensors for other measurands. A communications interface for such a sensor has been specified. Instrument Digital Output Sensor (IDOS) that permits this interchanagability and allows the sensor to be inside or outside the measuring instrument. This paper covers the design and specification of a silicon diaphragm piezo resistive SMART sensor using this interface. A brief history of instrument sensors will be given to establish the background to this development. Design choices of the silicon doping, bridge energisation method, temperature sensing, signal conversion, data processing, compensation method, communications interface will be discussed. The physical format of the `in-instrument' version will be shown and then extended to the packaging design for the external version. Test results will show the accuracy achieved exceeds the target of 0.01%FS over a range of temperatures.
The European Social Fund: A Very Specific Case Instrument of HRD Policy
ERIC Educational Resources Information Center
Tome, Eduardo
2013-01-01
Purpose: This paper aims to review the intervention of the European Social Fund (ESF) as an instrument of human resource development (HRD) policies in the European labor market. Design/methodology/approach: The paper uses an economic background, and reviews the official documents produced by the ESF during its history to try to define its economic…
Jiang, Feng; Bai, Jingfeng; Chen, Yazhu
2005-08-01
Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.
Newham, Rosemary; Bennie, Marion; Maxwell, David; Watson, Anne; de Wet, Carl; Bowie, Paul
2014-12-01
A positive and strong safety culture underpins effective learning from patient safety incidents in health care, including the community pharmacy (CP) setting. To build this culture, perceptions of safety climate must be measured with context-specific and reliable instruments. No pre-existing instruments were specifically designed or suitable for CP within Scotland. We therefore aimed to develop a psychometrically sound instrument to measure perceptions of safety climate within Scottish CPs. The first stage, development of a preliminary instrument, comprised three steps: (i) a literature review; (ii) focus group feedback; and (iii) content validation. The second stage, psychometric testing, consisted of three further steps: (iv) a pilot survey; (v) a survey of all CP staff within a single health board in NHS Scotland; and (vi) application of statistical methods, including principal components analysis and calculation of Cronbach's reliability coefficients, to derive the final instrument. The preliminary questionnaire was developed through a process of literature review and feedback. This questionnaire was completed by staff in 50 CPs from the 131 (38%) sampled. 250 completed questionnaires were suitable for analysis. Psychometric evaluation resulted in a 30-item instrument with five positively correlated safety climate factors: leadership, teamwork, safety systems, communication and working conditions. Reliability coefficients were satisfactory for the safety climate factors (α > 0.7) and overall (α = 0.93). The robust nature of the technical design and testing process has resulted in the development of an instrument with sufficient psychometric properties, which can be implemented in the community pharmacy setting in NHS Scotland. © 2014 John Wiley & Sons, Ltd.
A study for hypergolic vapor sensor development
NASA Technical Reports Server (NTRS)
Stetter, J. R.
1977-01-01
The use of an electrochemical technique for MMH and N02 measurement was investigated. Specific MMH and N02 electrochemical sensors were developed. Experimental techniques for preparation, handling, and analysis of hydrazine's vapor mixtures at ppb and ppm levels were developed. Two approaches to N02 instrument design were evaluated including specific adsorption and specific electrochemical reduction. Two approaches to hydrazines monitoring were evaluated including catalytic conversion to N0 with subsequent N0 detection and direct specific electrochemical oxidation. Two engineering prototype MMH/N02 monitors were designed and constructed.
CICADA, CCD and Instrument Control Software
NASA Astrophysics Data System (ADS)
Young, Peter J.; Brooks, Mick; Meatheringham, Stephen J.; Roberts, William H.
Computerised Instrument Control and Data Acquisition (CICADA) is a software system for control of telescope instruments in a distributed computing environment. It is designed using object-oriented techniques and built with standard computing tools such as RPC, SysV IPC, Posix threads, Tcl, and GUI builders. The system is readily extensible to new instruments and currently supports the Astromed 3200 CCD controller and MSSSO's new tip-tilt system. Work is currently underway to provide support for the SDSU CCD controller and MSSSO's Double Beam Spectrograph. A core set of processes handle common communication and control tasks, while specific instruments are ``bolted'' on using C++ inheritance techniques.
Instrument Systems Analysis and Verification Facility (ISAVF) users guide
NASA Technical Reports Server (NTRS)
Davis, J. F.; Thomason, J. O.; Wolfgang, J. L.
1985-01-01
The ISAVF facility is primarily an interconnected system of computers, special purpose real time hardware, and associated generalized software systems, which will permit the Instrument System Analysts, Design Engineers and Instrument Scientists, to perform trade off studies, specification development, instrument modeling, and verification of the instrument, hardware performance. It is not the intent of the ISAVF to duplicate or replace existing special purpose facilities such as the Code 710 Optical Laboratories or the Code 750 Test and Evaluation facilities. The ISAVF will provide data acquisition and control services for these facilities, as needed, using remote computer stations attached to the main ISAVF computers via dedicated communication lines.
3D Printed Surgical Instruments: The Design and Fabrication Process.
George, Mitchell; Aroom, Kevin R; Hawes, Harvey G; Gill, Brijesh S; Love, Joseph
2017-01-01
3D printing is an additive manufacturing process allowing the creation of solid objects directly from a digital file. We believe recent advances in additive manufacturing may be applicable to surgical instrument design. This study investigates the feasibility, design and fabrication process of usable 3D printed surgical instruments. The computer-aided design package SolidWorks (Dassault Systemes SolidWorks Corp., Waltham MA) was used to design a surgical set including hemostats, needle driver, scalpel handle, retractors and forceps. These designs were then printed on a selective laser sintering (SLS) Sinterstation HiQ (3D Systems, Rock Hill SC) using DuraForm EX plastic. The final printed products were evaluated by practicing general surgeons for ergonomic functionality and performance, this included simulated surgery and inguinal hernia repairs on human cadavers. Improvements were identified and addressed by adjusting design and build metrics. Repeated manufacturing processes and redesigns led to the creation of multiple functional and fully reproducible surgical sets utilizing the user feedback of surgeons. Iterative cycles including design, production and testing took an average of 3 days. Each surgical set was built using the SLS Sinterstation HiQ with an average build time of 6 h per set. Functional 3D printed surgical instruments are feasible. Advantages compared to traditional manufacturing methods include no increase in cost for increased complexity, accelerated design to production times and surgeon specific modifications.
Inertial Pointing and Positioning System
NASA Technical Reports Server (NTRS)
Yee, Robert (Inventor); Robbins, Fred (Inventor)
1998-01-01
An inertial pointing and control system and method for pointing to a designated target with known coordinates from a platform to provide accurate position, steering, and command information. The system continuously receives GPS signals and corrects Inertial Navigation System (INS) dead reckoning or drift errors. An INS is mounted directly on a pointing instrument rather than in a remote location on the platform for-monitoring the terrestrial position and instrument attitude. and for pointing the instrument at designated celestial targets or ground based landmarks. As a result. the pointing instrument and die INS move independently in inertial space from the platform since the INS is decoupled from the platform. Another important characteristic of the present system is that selected INS measurements are combined with predefined coordinate transformation equations and control logic algorithms under computer control in order to generate inertial pointing commands to the pointing instrument. More specifically. the computer calculates the desired instrument angles (Phi, Theta. Psi). which are then compared to the Euler angles measured by the instrument- mounted INS. and forms the pointing command error angles as a result of the compared difference.
Boerma, Tessel; Chiat, Shula; Leseman, Paul; Timmermeister, Mona; Wijnen, Frank; Blom, Elma
2015-12-01
This study evaluated a newly developed quasi-universal nonword repetition task (Q-U NWRT) as a diagnostic tool for bilingual children with language impairment (LI) who have Dutch as a 2nd language. The Q-U NWRT was designed to be minimally influenced by knowledge of 1 specific language in contrast to a language-specific NWRT with which it was compared. One hundred twenty monolingual and bilingual children with and without LI participated (30 per group). A mixed-design analysis of variance was used to investigate the effects of LI and bilingualism on the NWRTs. Receiver operating characteristic analyses were conducted to evaluate the instruments' diagnostic value. Large negative effects of LI were found on both NWRTs, whereas negative effects of bilingualism only occurred on the language-specific NWRT. Both instruments had high clinical accuracy in the monolingual group, but only the Q-U NWRT had high clinical accuracy in the bilingual group. This study indicates that the Q-U NWRT is a promising diagnostic tool to help identify LI in bilingual children learning Dutch as a 2nd language. The instrument was clinically accurate in both a monolingual and bilingual group of children and seems better able to disentangle LI from language disadvantage than more language-specific measures.
The HCMM system: Development and performance
NASA Technical Reports Server (NTRS)
Stuart, L. M., Jr.
1982-01-01
The structure and history of the heat capacity mapping mission program is reviewed and the spacecraft is described including engineering specifications, instrument design, data handling, and image characteristics.
Instrumental biosensors: new perspectives for the analysis of biomolecular interactions.
Nice, E C; Catimel, B
1999-04-01
The use of instrumental biosensors in basic research to measure biomolecular interactions in real time is increasing exponentially. Applications include protein-protein, protein-peptide, DNA-protein, DNA-DNA, and lipid-protein interactions. Such techniques have been applied to, for example, antibody-antigen, receptor-ligand, signal transduction, and nuclear receptor studies. This review outlines the principles of two of the most commonly used instruments and highlights specific operating parameters that will assist in optimising experimental design, data generation, and analysis.
Image dissector control and data system, part 1. [instrument packages and equipment specifications
NASA Technical Reports Server (NTRS)
1974-01-01
A general description of the image dissector control and data system is presented along with detailed design information, operating instructions, and maintenance and trouble-shooting procedures for the four instrumentation packages. The four instrumentation packages include a 90 inch telescope, a simplified telescope module for use on the 90 inch or other telescopes, a photographic plate scanner module which permits the scanning of astronomical photographic plates in the laboratory, and the lunar experiment package module.
INTEGRATED MONITORING HARDWARE DEVELOPMENTS AT LOS ALAMOS
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. PARKER; J. HALBIG; ET AL
1999-09-01
The hardware of the integrated monitoring system supports a family of instruments having a common internal architecture and firmware. Instruments can be easily configured from application-specific personality boards combined with common master-processor and high- and low-voltage power supply boards, and basic operating firmware. The instruments are designed to function autonomously to survive power and communication outages and to adapt to changing conditions. The personality boards allow measurement of gross gammas and neutrons, neutron coincidence and multiplicity, and gamma spectra. In addition, the Intelligent Local Node (ILON) provides a moderate-bandwidth network to tie together instruments, sensors, and computers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geiger, David K
2015-12-31
An Agilent 400-MR nuclear magnetic resonance (NMR) spectrometer and ancillary equipment were purchased, which are being used for molecular structure elucidation. The instrumentation is housed in a pre-existing facility designed specifically for its use. This instrument package is being used to expand the research and educational efforts of the faculty and students at SUNY-Geneseo and is made available to neighboring educational institutions and business concerns. Funds were also used for training of College personnel, maintenance of the instrumentation, and installation of the equipment.
Droplet Combustion and Non-Reactive Shear-Coaxial Jets with Transverse Acoustic Excitation
2012-06-01
Shear-Coaxial Jets Experimental Facility: Piping and Instrumentation Diagram . . . . . . . . . . . . . . . . . . . . . . 196 B Shear-Coaxial Jets...facility piping and instrumentation diagram. . . . . . . . . 197 A.2 Expanded view of section A in Figure A.1. . . . . . . . . . . . . . . . . . 198 A.3...certified to be used in flexible fuel vehicles (FFVs) with engines specifically designed for this fuel. As for possible aviation fuel replacements
ERIC Educational Resources Information Center
Mutto, Milton; Mukasa, Immaculate; Avasi, Victor; Kilibo, Charles; Kamwesigye, Charles; Duku, Tom
2015-01-01
This study determined psychometric properties of 3-ET, an instrument specifically designed to track the effects of a curriculum support intervention created to enhance the delivery of the national curriculum in a war zone in Uganda. The instrument was developed through brain storm and expert review before being committed to structural and…
WFF TOPEX Software Documentation Altimeter Instrument File (AIF) Processing, October 1998. Volume 3
NASA Technical Reports Server (NTRS)
Lee, Jeffrey; Lockwood, Dennis
2003-01-01
This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Sensor Data Record (SDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.
specification was achieved by simplifying and improving the basic Bendix dosimeter design, using plastics for component parts, minimizing direct labor, and making the instrument suitable for automated processing and assembly. (Author)
77 FR 71794 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-04
... in that community. Formative research is research that occurs before a program is designed and... entirely behavioral but most often they are cycles of interviews and focus groups designed to inform the... specific data collection instruments, (3) methodological research (4) usability testing of technology-based...
Electrical Auxiliary Power Unit (EAPU) Corona Design Guideline. Revised
NASA Technical Reports Server (NTRS)
Hall, David K.; Kirkici, Hulya; Schweickart, Dan L.; Dunbar, William; Hillard, Barry
2000-01-01
This document is the result of a collaborative effort between NASA's Johnson Space Center, Marshall Space Flight Center, Glenn Research Center, and the United States Air Force Research Laboratory at Wright Patterson AFB in support of the Space Shuttle Orbiter Upgrades Program, specifically the Electric Auxiliary Power Unit Program. This document is intended as a guideline for design applications for corona and partial discharge avoidance and is not a requirements specification instrument.
Compact multispectral photodiode arrays using micropatterned dichroic filters
NASA Astrophysics Data System (ADS)
Chandler, Eric V.; Fish, David E.
2014-05-01
The next generation of multispectral instruments requires significant improvements in both spectral band customization and portability to support the widespread deployment of application-specific optical sensors. The benefits of spectroscopy are well established for numerous applications including biomedical instrumentation, industrial sorting and sensing, chemical detection, and environmental monitoring. In this paper, spectroscopic (and by extension hyperspectral) and multispectral measurements are considered. The technology, tradeoffs, and application fits of each are evaluated. In the majority of applications, monitoring 4-8 targeted spectral bands of optimized wavelength and bandwidth provides the necessary spectral contrast and correlation. An innovative approach integrates precision spectral filters at the photodetector level to enable smaller sensors, simplify optical designs, and reduce device integration costs. This method supports user-defined spectral bands to create application-specific sensors in a small footprint with scalable cost efficiencies. A range of design configurations, filter options and combinations are presented together with typical applications ranging from basic multi-band detection to stringent multi-channel fluorescence measurement. An example implementation packages 8 narrowband silicon photodiodes into a 9x9mm ceramic LCC (leadless chip carrier) footprint. This package is designed for multispectral applications ranging from portable color monitors to purpose- built OEM industrial and scientific instruments. Use of an eight-channel multispectral photodiode array typically eliminates 10-20 components from a device bill-of-materials (BOM), streamlining the optical path and shrinking the footprint by 50% or more. A stepwise design approach for multispectral sensors is discussed - including spectral band definition, optical design tradeoffs and constraints, and device integration from prototype through scalable volume production. Additional customization options are explored for application-specific OEM sensors integrated into portable devices using multispectral photodiode arrays.
The Development of a Vocational Diagnostic Program. Interim Report.
ERIC Educational Resources Information Center
Barnard, William W.
A five-phased project is described which was designed to develop more specific diagnostic procedures and instrumentation that would allow both the vocational counselor and the prospective student to determine more effectively specific occupational programs and occupational objectives for education at the postsecondary level. Phases of the project…
Solid state instrumentation concepts for earth resource observation
NASA Technical Reports Server (NTRS)
Richard, H. L.
1982-01-01
Late in 1980, specifications were prepared for detail design definition of a six band solid state multispectral instrument having three visible (VIS), one near infrared (NIR), and two short wave infrared (SWIR) bands. This instrument concept, known as the Multispectral Linear Array (MLA), also offered increased spatial resolution, on board gain and offset correction, and additional operational modes which would allow for cross track and stereoscopic viewing as well as a multialtitude operational capability. A description is presented of a summary of some of the salient features of four different MLA design concepts, as developed by four American companies. The designs ranged from the use of multiple refractive telescopes utilizing three groups of focal plane detectors electronic correlation processing for achieving spatial registration, and incorporating palladium silicide (PdSi) SWIR detectors, to a four-mirror all-reflective telecentric system utilizing a beam splitter for spatial registration.
ERIC Educational Resources Information Center
Chhokar, Kiran; Dua, Shweta; Taylor, Neil; Boyes, Edward; Stanisstreet, Martin
2011-01-01
A 44-item survey instrument was designed to determine secondary students' views about how useful various specific actions related to reducing global warming might be, their willingness to undertake these various actions and the extent to which these 2 might be linked. The instrument was administered to students in grades 6-10 (n = 768) from 4…
Multi-disciplinary Ocean Sensors for Environmental Analyses and Networks (MOSEAN)
2003-09-30
will require optimization for their application . Modifications will include: a) Size and power reduction of the electro-fluidic component to match...instrument can be configured for detection of CDOM, phycocyanin , phycoerythrin, and chlorophyll-a depending upon the specific wavelengths chosen. Efforts...OPL in Santa Barbara. Discussions centered on new instrumentation designed for coastal applications and plans for the CHARM mooring (site selection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melin, Alexander M.; Kisner, Roger A.
2016-09-01
Embedded instrumentation and control systems that can operate in extreme environments are challenging to design and operate. Extreme environments limit the options for sensors and actuators and degrade their performance. Because sensors and actuators are necessary for feedback control, these limitations mean that designing embedded instrumentation and control systems for the challenging environments of nuclear reactors requires advanced technical solutions that are not available commercially. This report details the development of testbed that will be used for cross-cutting embedded instrumentation and control research for nuclear power applications. This research is funded by the Department of Energy's Nuclear Energy Enabling Technologymore » program's Advanced Sensors and Instrumentation topic. The design goal of the loop-scale testbed is to build a low temperature pump that utilizes magnetic bearing that will be incorporated into a water loop to test control system performance and self-sensing techniques. Specifically, this testbed will be used to analyze control system performance in response to nonlinear and cross-coupling fluid effects between the shaft axes of motion, rotordynamics and gyroscopic effects, and impeller disturbances. This testbed will also be used to characterize the performance losses when using self-sensing position measurement techniques. Active magnetic bearings are a technology that can reduce failures and maintenance costs in nuclear power plants. They are particularly relevant to liquid salt reactors that operate at high temperatures (700 C). Pumps used in the extreme environment of liquid salt reactors provide many engineering challenges that can be overcome with magnetic bearings and their associated embedded instrumentation and control. This report will give details of the mechanical design and electromagnetic design of the loop-scale embedded instrumentation and control testbed.« less
Cascadia Initiative Ocean Bottom Seismograph Performance
NASA Astrophysics Data System (ADS)
Evers, B.; Aderhold, K.
2017-12-01
The Ocean Bottom Seismograph Instrument Pool (OBSIP) provided instrumentation and operations support for the Cascadia Initiative community experiment. This experiment investigated geophysical processes across the Cascadia subduction zone through a combination of onshore and offshore seismic data. The recovery of Year 4 instruments in September 2015 marked the conclusion of a multi-year experiment that utilized 60 ocean-bottom seismographs (OBSs) specifically designed for the subduction zone boundary, including shallow/deep water deployments and active fisheries. The new instruments featured trawl-resistant enclosures designed by Lamont-Doherty Earth Observatory (LDEO) and Scripps Institution of Oceanography (SIO) for shallow deployment [water depth ≤ 500 m], as well as new deep-water instruments designed by Woods Hole Oceanographic Institute (WHOI). Existing OBSIP instruments were also deployed along the Blanco Transform Fault and on the Gorda Plate through complementary experiments. Station instrumentation included weak and strong motion seismometers, differential pressure gauges (DPG) and absolute pressure gauges (APG). All data collected from the Cascadia, Blanco, and Gorda deployments is available through the Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC). The Cascadia Initiative is the largest amphibious seismic experiment undertaken to date, encompassing a diverse technical implementation and demonstrating an effective structure for community experiments. Thus, the results from Cascadia serve as both a technical and operational resource for the development of future community experiments, such as might be contemplated as part of the SZ4D Initiative. To guide future efforts, we investigate and summarize the quality of the Cascadia OBS data using basic metrics such as instrument recovery and more advanced metrics such as noise characteristics through power spectral density analysis. We also use this broad and diverse deployment to explore other environmental and configuration factors that can impact sensor and network performance and inform the design of future deployments.
Utilization of the High Flux Isotope Reactor at Oak Ridge National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selby, Douglas L; Bilheux, Hassina Z; Meilleur, Flora
2015-01-01
This paper addresses several aspects of the scientific utilization of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Topics to be covered will include: 1) HFIR neutron scattering instruments and the formal instrument user program; 2) Recent upgrades to the neutron scattering instrument stations at the reactor, and 3) eMod a new tool for addressing instrument modifications and providing configuration control and design process for scientific instruments at HFIR and the Spallation Neutron Source (SNS). There are 15 operating neutron instrument stations at HFIR with 12 of them organized into a formal user program. Since the last presentationmore » on HFIR instruments at IGORR we have installed a Single Crystal Quasi-Laue Diffractometer instrument called IMAGINE; and we have made significant upgrades to HFIR neutron scattering instruments including the Cold Triple Axis Instrument, the Wide Angle Neutron Diffractometer, the Powder Diffractometer, and the Neutron Imaging station. In addition, we have initiated upgrades to the Thermal Triple Axis Instrument and the Bio-SANS cold neutron instrument detector system. All of these upgrades are tied to a continuous effort to maintain a high level neutron scattering user program at the HFIR. For the purpose of tracking modifications such as those mentioned and configuration control we have been developing an electronic system for entering instrument modification requests that follows a modification or instrument project through concept development, design, fabrication, installation, and commissioning. This system, which we call eMod, electronically leads the task leader through a series of questions and checklists that then identifies such things as ES&H and radiological issues and then automatically designates specific individuals for the activity review process. The system has been in use for less than a year and we are still working out some of the inefficiencies, but we believe that this will become a very effective tool for achieving the configuration and process control believed to be necessary for scientific instrument systems.« less
Wickert, Natasha M; Wong Riff, Karen W Y; Mansour, Mark; Forrest, Christopher R; Goodacre, Timothy E E; Pusic, Andrea L; Klassen, Anne F
2018-01-01
Objective The aim of this systematic review was to identify patient-reported outcome (PRO) instruments used in research with children/youth with conditions associated with facial differences to identify the health concepts measured. Design MEDLINE, EMBASE, CINAHL, and PsycINFO were searched from 2004 to 2016 to identify PRO instruments used in acne vulgaris, birthmarks, burns, ear anomalies, facial asymmetries, and facial paralysis patients. We performed a content analysis whereby the items were coded to identify concepts and categorized as positive or negative content or phrasing. Results A total of 7,835 articles were screened; 6 generic and 11 condition-specific PRO instruments were used in 96 publications. Condition-specific instruments were for acne (four), oral health (two), dermatology (one), facial asymmetries (two), microtia (one), and burns (one). The PRO instruments provided 554 items (295 generic; 259 condition specific) that were sorted into 4 domains, 11 subdomains, and 91 health concepts. The most common domain was psychological (n = 224 items). Of the identified items, 76% had negative content or phrasing (e.g., "Because of the way my face looks I wish I had never been born"). Given the small number of items measuring facial appearance (n = 19) and function (n = 22), the PRO instruments reviewed lacked content validity for patients whose condition impacted facial function and/or appearance. Conclusions Treatments can change facial appearance and function. This review draws attention to a problem with content validity in existing PRO instruments. Our team is now developing a new PRO instrument called FACE-Q Kids to address this problem.
The phase-contrast imaging instrument at the matter in extreme conditions endstation at LCLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagler, Bob; Schropp, Andreas; Galtier, Eric C.
2016-10-07
Here, we describe the phase-contrast imaging instrument at the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source. The instrument can image phenomena with a spatial resolution of a few hundreds of nanometers and at the same time reveal the atomic structure through X-ray diffraction, with a temporal resolution better than 100 fs. It was specifically designed for studies relevant to high-energy-density science and can monitor, e.g., shock fronts, phase transitions, or void collapses. This versatile instrument was commissioned last year and is now available to the MEC user community.
Study of the true performance limits of the Astrometric Multiplexing Area Scanner (AMAS)
NASA Technical Reports Server (NTRS)
Frederick, L. W.; Mcalister, H. A.
1975-01-01
The Astrometric Multiplexing Area Scanner (AMAS) is an instrument designed to perform photoelectric long focus astrometry of small fields. Modulation of a telescope focal plane with a rotating Ronchi ruling produces a frequency modulated signal from which relative positions and magnitudes can be extracted. Evaluation instrumental precision, accuracy and resolution characteristics with respect to a variety of instrumental and cosmical parameters indicates 1.5 micron precision and accuracy for single stars under specific conditions. This value decreases for increased number of field stars, particularly for fainter stars.
NASA Astrophysics Data System (ADS)
Randol, B. M.; Ebert, R. W.; Allegrini, F.; McComas, D. J.; Schwadron, N. A.
2010-11-01
Electrostatic analyzers (ESAs), in various forms, are used to measure plasma in a range of applications. In this article, we describe how ions reflect from the interior surfaces of an ESA, the detection of which constitutes a fundamentally nonideal response of ESAs. We demonstrate this effect by comparing laboratory data from a real ESA-based space instrument, the Solar Wind Around Pluto (SWAP) instrument, aboard the NASA New Horizons spacecraft, to results from a model based on quantum mechanical simulations of particles reflected from the instrument's surfaces combined with simulations of particle trajectories through the instrument's applied electrostatic fields. Thus, we show, for the first time, how reflected ions in ESAs lead to nonideal effects that have important implications for understanding the data returned by these instruments, as well as for designing new low-background ESA-based instruments. Specifically, we show that the response of SWAP widens considerably below a level of 10-3 of the peak response. Thus, a direct measurement of a plasma distribution with SWAP will have an energy-dependent background on the order of <=10-3 of the peak of the signal due to that distribution. We predict that this order of magnitude estimate for the background applies to a large number of ESA-based instruments because ESAs operate using a common principle. However, the exact shape of the energy-dependent response will be different for different instruments. The principle of operation is that ions outside the ideal range of energy-per-charge are deflected into the walls of the ESA. Therefore, we propose that a new design paradigm is necessary to mitigate the effect of ion reflections and thus accurately and directly measure the energy spectrum of a plasma using ESAs. In this article, we build a framework for minimizing the effect of ion reflections in the design of new ESAs. Through the use of existing computer simulation software, a design team can use our method to quantify the amount of reflections in their instrument and iteratively change design parameters before fabrication, conserving resources. A possible direction for the new design paradigm is having nonsolid walls of the ESA, already used in some applications.
NIR light propagation in a digital head model for traumatic brain injury (TBI)
Francis, Robert; Khan, Bilal; Alexandrakis, George; Florence, James; MacFarlane, Duncan
2015-01-01
Near infrared spectroscopy (NIRS) is capable of detecting and monitoring acute changes in cerebral blood volume and oxygenation associated with traumatic brain injury (TBI). Wavelength selection, source-detector separation, optode density, and detector sensitivity are key design parameters that determine the imaging depth, chromophore separability, and, ultimately, clinical usefulness of a NIRS instrument. We present simulation results of NIR light propagation in a digital head model as it relates to the ability to detect intracranial hematomas and monitor the peri-hematomal tissue viability. These results inform NIRS instrument design specific to TBI diagnosis and monitoring. PMID:26417498
Lessons Learned from the Advanced Topographic Laser Altimeter System
NASA Technical Reports Server (NTRS)
Garrison, Matt; Patel, Deepak; Bradshaw, Heather; Robinson, Frank; Neuberger, Dave
2016-01-01
The ICESat-2 Advanced Topographic Laser Altimeter System (ATLAS) instrument is an upcoming Earth Science mission focusing on the effects of climate change. The flight instrument passed all environmental testing at GSFC (Goddard Space Flight Center) and is now ready to be shipped to the spacecraft vendor for integration and testing. This presentation walks through the lessons learned from design, hardware, analysis and testing perspective. ATLAS lessons learned include general thermal design, analysis, hardware, and testing issues as well as lessons specific to laser systems, two-phase thermal control, and optical assemblies with precision alignment requirements.
A systematic review of instruments for measuring outcomes in economic evaluation within aged care.
Bulamu, Norma B; Kaambwa, Billingsley; Ratcliffe, Julie
2015-11-09
This paper describes the methods and results of a systematic review to identify instruments used to measure quality of life outcomes in older people. The primary focus of the review was to identify instruments suitable for application with older people within economic evaluations conducted in the aged care sector. Online databases searched were PubMed, Medline, Scopus, and Web of Science, PsycInfo, CINAHL, Embase and Informit. Studies that met the following criteria were included: 1) study population exclusively above 65 years of age 2) measured health status, health related quality of life or quality of life outcomes more broadly through use of an instrument developed for this purpose, 3) used a generic preference based instrument or an older person specific preference based or non-preference based instrument or both, and 4) published in journals in the English language after 2000. The most commonly applied generic preference based instrument in both the community and residential aged care context was the EuroQol - 5 Dimensions (EQ-5D), followed by the Adult Social Care Outcomes Toolkit (ASCOT) and the Health Utilities Index (HUI2/3). The most widely applied older person specific instrument was the ICEpop CAPability measure for Older people (ICECAP-O) in both community and residential aged care. In the absence of an ideal instrument for incorporating into economic evaluations in the aged care sector, this review recommends the use of a generic preference based measure of health related quality of life such as the EQ-5D to obtain quality adjusted life years, in combination with an instrument that has a broader quality of life focus like the ASCOT, which was designed specifically for evaluating interventions in social care or the ICECAP-O, a capability measure for older people.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Theys, M.
1994-05-06
Beamlet is a high power laser currently being built at Lawrence Livermore National Lab as a proof of concept for the National Ignition Facility (NIF). Beamlet is testing several areas of laser advancements, such as a 37cm Pockels cell, square amplifier, and propagation of a square beam. The diagnostics on beamlet tell the operators how much energy the beam has in different locations, the pulse shape, the energy distribution, and other important information regarding the beam. This information is being used to evaluate new amplifier designs, and extrapolate performance to the NIF laser. In my term at Lawrence Livermore Nationalmore » Laboratory I have designed and built a diagnostic, calibrated instruments used on diagnostics, setup instruments, hooked up communication lines to the instruments, and setup computers to control specific diagnostics.« less
Population-based metaheuristic optimization in neutron optics and shielding design
NASA Astrophysics Data System (ADS)
DiJulio, D. D.; Björgvinsdóttir, H.; Zendler, C.; Bentley, P. M.
2016-11-01
Population-based metaheuristic algorithms are powerful tools in the design of neutron scattering instruments and the use of these types of algorithms for this purpose is becoming more and more commonplace. Today there exists a wide range of algorithms to choose from when designing an instrument and it is not always initially clear which may provide the best performance. Furthermore, due to the nature of these types of algorithms, the final solution found for a specific design scenario cannot always be guaranteed to be the global optimum. Therefore, to explore the potential benefits and differences between the varieties of these algorithms available, when applied to such design scenarios, we have carried out a detailed study of some commonly used algorithms. For this purpose, we have developed a new general optimization software package which combines a number of common metaheuristic algorithms within a single user interface and is designed specifically with neutronic calculations in mind. The algorithms included in the software are implementations of Particle-Swarm Optimization (PSO), Differential Evolution (DE), Artificial Bee Colony (ABC), and a Genetic Algorithm (GA). The software has been used to optimize the design of several problems in neutron optics and shielding, coupled with Monte-Carlo simulations, in order to evaluate the performance of the various algorithms. Generally, the performance of the algorithms depended on the specific scenarios, however it was found that DE provided the best average solutions in all scenarios investigated in this work.
Measuring Literary Reading Motivation: Questionnaires Design and Pilot Testing
ERIC Educational Resources Information Center
Chrysos, Michail
2017-01-01
This study aims to present the design and pilot testing procedures of the two specific self-report questionnaires were used to measure the two key aspects of reading motivation, self-efficacy and intrinsic motivation in the field of literary (narrative) reading, and the partial factors that jointly shape them. These instruments were outlined in…
29 CFR 1926.906 - Initiation of explosive charges-electric blasting.
Code of Federal Regulations, 2013 CFR
2013-07-01
...” position at all times, except when firing. It shall be so designed that the firing lines to the cap circuit... blasting machine shall not be in excess of its rated capacity. Furthermore, in primary blasting, a series..., shall use only blasting galvanometers or other instruments that are specifically designed for this...
29 CFR 1926.906 - Initiation of explosive charges-electric blasting.
Code of Federal Regulations, 2014 CFR
2014-07-01
...” position at all times, except when firing. It shall be so designed that the firing lines to the cap circuit... blasting machine shall not be in excess of its rated capacity. Furthermore, in primary blasting, a series..., shall use only blasting galvanometers or other instruments that are specifically designed for this...
29 CFR 1926.906 - Initiation of explosive charges-electric blasting.
Code of Federal Regulations, 2012 CFR
2012-07-01
...” position at all times, except when firing. It shall be so designed that the firing lines to the cap circuit... blasting machine shall not be in excess of its rated capacity. Furthermore, in primary blasting, a series..., shall use only blasting galvanometers or other instruments that are specifically designed for this...
29 CFR 1926.906 - Initiation of explosive charges-electric blasting.
Code of Federal Regulations, 2011 CFR
2011-07-01
...” position at all times, except when firing. It shall be so designed that the firing lines to the cap circuit... blasting machine shall not be in excess of its rated capacity. Furthermore, in primary blasting, a series..., shall use only blasting galvanometers or other instruments that are specifically designed for this...
Recent progress in the design and clinical development of electronic-nose technologies
Dan Wilson
2016-01-01
Electronic-nose (e-nose) devices are instruments designed to detect and discriminate between precise complex gaseous mixtures of volatile organic compounds derived from specific organic sources, such as clinical test samples from patients, based on electronic aroma signature patterns (distinct digital sensor responses) resulting from the combined outputs of a...
The interplanetary Pioneers. Volume 2: System design and development
NASA Technical Reports Server (NTRS)
Corliss, W. R.
1972-01-01
The Pioneer systems, subsystems, and ground support activities are described. Details are given on the launch trajectory and solar orbit plans, spacecraft design approach and evolution, scientific instrument, test and ground support equipment, Delta launch vehicle, tracking and communication, and data processing equipment. Pioneer specifications, and reliability and quality assurance are also included.
Dynamics explorer: Interface definition study, volume 1
NASA Technical Reports Server (NTRS)
1978-01-01
Work done in response to the work statement wherein a specific deliverable was not identified but where design and analysis tasks were identified is reported. The summary and baseline change list is included along with design notes for the spacecraft system, thermal subsystem, power subsystem, communications subsystem, plasma wave instrument interface definition, and the structure.
The Contours of Inclusion: Frameworks and Tools for Evaluating Arts in Education
ERIC Educational Resources Information Center
Glass, Don; Palmer Wolf, Dennie; Molloy, Traci; Rodriguez, Aamir; Horowitz, Robert; Burnaford, Gail; Mertens, Donna M.
2008-01-01
This collection of essays explores various arts education-specific evaluation tools, as well as considers Universal Design for Learning (UDL) and the inclusion of people with disabilities in the design of evaluation instruments and strategies. Prominent evaluators Donna M. Mertens, Robert Horowitz, Dennie Palmer Wolf, and Gail Burnaford are…
NASA Technical Reports Server (NTRS)
1994-01-01
This Interface Control Document (ICD) defines the specific details of the complete accomodation information between the Earth Observing System (EOS) PM Spacecraft and the Advanced Microwave Sounding Unit (AMSU-A)Instrument. This is the first submittal of the ICN: it will be updated periodically throughout the life of the program. The next update is planned prior to Critical Design Review (CDR).
Lithium Circuit Test Section Design and Fabrication
NASA Technical Reports Server (NTRS)
Godfroy, Thomas; Garber, Anne
2006-01-01
The Early Flight Fission - Test Facilities (EFF-TF) team has designed and built an actively pumped lithium flow circuit. Modifications were made to a circuit originally designed for NaK to enable the use of lithium that included application specific instrumentation and hardware. Component scale freeze/thaw tests were conducted to both gain experience with handling and behavior of lithium in solid and liquid form and to supply anchor data for a Generalized Fluid System Simulation Program (GFSSP) model that was modified to include the physics for freeze/thaw transitions. Void formation was investigated. The basic circuit components include: reactor segment, lithium to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and trace heaters. This paper will discuss the overall system design and build and the component testing findings.
Lithium Circuit Test Section Design and Fabrication
NASA Astrophysics Data System (ADS)
Godfroy, Thomas; Garber, Anne; Martin, James
2006-01-01
The Early Flight Fission - Test Facilities (EFF-TF) team has designed and built an actively pumped lithium flow circuit. Modifications were made to a circuit originally designed for NaK to enable the use of lithium that included application specific instrumentation and hardware. Component scale freeze/thaw tests were conducted to both gain experience with handling and behavior of lithium in solid and liquid form and to supply anchor data for a Generalized Fluid System Simulation Program (GFSSP) model that was modified to include the physics for freeze/thaw transitions. Void formation was investigated. The basic circuit components include: reactor segment, lithium to gas heat exchanger, electromagnetic (EM) liquid metal pump, load/drain reservoir, expansion reservoir, instrumentation, and trace heaters. This paper discusses the overall system design and build and the component testing findings.
Human-Centered Design of Human-Computer-Human Dialogs in Aerospace Systems
NASA Technical Reports Server (NTRS)
Mitchell, Christine M.
1998-01-01
A series of ongoing research programs at Georgia Tech established a need for a simulation support tool for aircraft computer-based aids. This led to the design and development of the Georgia Tech Electronic Flight Instrument Research Tool (GT-EFIRT). GT-EFIRT is a part-task flight simulator specifically designed to study aircraft display design and single pilot interaction. ne simulator, using commercially available graphics and Unix workstations, replicates to a high level of fidelity the Electronic Flight Instrument Systems (EFIS), Flight Management Computer (FMC) and Auto Flight Director System (AFDS) of the Boeing 757/767 aircraft. The simulator can be configured to present information using conventional looking B757n67 displays or next generation Primary Flight Displays (PFD) such as found on the Beech Starship and MD-11.
Monitoring of water supply connections as an element to reduce apparent losses of water?
NASA Astrophysics Data System (ADS)
Gwoździej-Mazur, Joanna
2017-11-01
Measuring instruments are designed to measure a given physical value, to process the obtained information and forward it to the observer. They are designed to perform specific tasks in specific working conditions and meeting the envisaged requirements. The most important requirement to be met by measuring instruments, is to preserve the established metrological characteristics. The basic and most common instrument for measuring the volume of flowing water is the water meter. Selecting the right water meter in the operating conditions is not an easy issue. The problem has been further intensified by decrease of water consumption which began in the 90s of the twentieth century and continuing to the present day. As a result, there has changed the structure of water consumption in both the residential and industrial applications. In this situation, a right selection of the optimal water meter it is an important case. The article presents the results of research in the field of characteristic flows in the water supply connections in multi-family housing using modern monitoring systems. It has been presented the calculated inequality ratio of water consumption, which can be helpful when designing a plumbing systems. In addition, the structure of water consumption due to the typical flow ranges was determined.
A systematic review of motivational values and conservation success in and around protected areas.
Cetas, Elijah R; Yasué, Maï
2017-02-01
In conservation projects in and around protected areas (PAs), a suite of policy instruments are used to promote conservation behavior in local people. Few studies have related psychological research on motivational values to conservation in PAs. We conducted a systematic review of 120 peer-reviewed articles to assess the relative frequencies of policy instruments that aimed to foster intrinsic versus extrinsic motivations to conserve. We examined how the type of motivation engendered by the instrument (i.e., intrinsic or extrinsic motivation and based on the description of how the project was designed and implemented) influenced the ecological, economic, and social success of the project. We assessed the success of the project in only the case studies that included a quantitative or qualitative analysis of success. Projects designed to foster at least one intrinsically motivating instrument were 3 times more likely to meet socioeconomic or ecological goals. Although certain types of instruments such as payments or fines tended to be based on extrinsic motivators more often than education or monitoring programs, several successful projects involving payments or fines were linked to intrinsic motivation in the local community. Thus, our results suggest that rather than debating the relative merits of specific types of policy instruments, conservationists may have more success by focusing on how different motivators, suited to specific contexts, can better empower local communities to conserve. Broadly, our results suggest the current emphasis on social justice and well-being of local communities is a positive step toward protecting the world's remaining biodiversity. © 2016 Society for Conservation Biology.
NASA Technical Reports Server (NTRS)
1974-01-01
The Ground System requirements for the Land Resources Management (LRM) type-A and type-B missions of the Earth Observatory Satellite (EOS) program are presented. Specifications for the Thematic Mapper data processing are provided (LRM A mission). The specifications also cover the R and D instruments (Thematic Mapper and High Resolution Pointable Imager) data processing for the LRM type-B mission.
NASA Technical Reports Server (NTRS)
1974-01-01
The equipment specifications for the thematic mapper and high resolution pointable imager for use on the Earth Observatory Satellite (EOS) are presented. The interface requirements of the systems are defined. The interface requirements are extracted from the equipment specifications and are intended as a summary to be used by the system and spacecraft designer. The appropriate documentation from which the specifications of the equipment are established are identified.
Jennings, T A; Scheer, A; Emodi, A; Puderbach, L; King, S; Norton, T
1996-01-01
This paper demonstrates the importance of the inspection qualification (IQ). It was shown that the facilities were adequate to house the dryer and its associated instrumentation, and that the facilities had sufficient utilities to operate the dryer. The IQ established that the design and construction of the dryer was in agreement with the proposed hardware and design specifications. It was verified that the dryer was constructed in accordance with specifications set-forth by the equipment manufacturer.
Designing Successful Next-Generation Instruments to Detect the Epoch of Reionization
NASA Astrophysics Data System (ADS)
Thyagarajan, Nithyanandan; Hydrogen Epoch of Reionization Array (HERA) team, Murchison Widefield Array (MWA) team
2018-01-01
The Epoch of Reionization (EoR) signifies a period of intense evolution of the Inter-Galactic Medium (IGM) in the early Universe caused by the first generations of stars and galaxies, wherein they turned the neutral IGM to be completely ionized by redshift ≥ 6. This important epoch is poorly explored to date. Measurement of redshifted 21 cm line from neutral Hydrogen during the EoR is promising to provide the most direct constraints of this epoch. Ongoing experiments to detect redshifted 21 cm power spectrum during reionization, including the Murchison Widefield Array (MWA), Precision Array for Probing the Epoch of Reionization (PAPER), and the Low Frequency Array (LOFAR), appear to be severely affected by bright foregrounds and unaccounted instrumental systematics. For example, the spectral structure introduced by wide-field effects, aperture shapes and angular power patterns of the antennas, electrical and geometrical reflections in the antennas and electrical paths, and antenna position errors can be major limiting factors. These mimic the 21 cm signal and severely degrade the instrument performance. It is imperative for the next-generation of experiments to eliminate these systematics at their source via robust instrument design. I will discuss a generic framework to set cosmologically motivated antenna performance specifications and design strategies using the Precision Radio Interferometry Simulator (PRISim) -- a high-precision tool that I have developed for simulations of foregrounds and the instrument transfer function intended primarily for 21 cm EoR studies, but also broadly applicable to interferometer-based intensity mapping experiments. The Hydrogen Epoch of Reionization Array (HERA), designed in-part based on this framework, is expected to detect the 21 cm signal with high significance. I will present this framework and the simulations, and their potential for designing upcoming radio instruments such as HERA and the Square Kilometre Array (SKA).
Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P
2012-12-05
Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.
[Shoulder disability questionnaires: a systematic review].
Fayad, F; Mace, Y; Lefevre-Colau, M M
2005-07-01
To identify all available shoulder disability questionnaires designed to measure physical functioning and to examine those with satisfactory clinimetric quality. We used the Medline database and the "Guide des outils de mesure de l'évaluation en médecine physique et de réadaptation" textbook to search for questionnaires. Analysis took into account the development methodology, clinimetric quality of the instruments and frequency of their utilization. We classified the instruments according to the International Classification of Functioning, Disability and Health. Thirty-eight instruments have been developed to measure disease-, shoulder- or upper extremity-specific outcome. Four scales assess upper-extremity disability and 3 others shoulder disability. We found 6 scales evaluating disability and shoulder pain, 7 scales measuring the quality of life in patients with various conditions of the shoulder, 14 scales combining objective and subjective measures, 2 pain scales and 2 unclassified scales. Older instruments developed before the advent of modern measurement development methodology usually combine objective and subjective measures. Recent instruments were designed with appropriate methodology. Most are self-administered questionnaires. Numerous shoulder outcome measure instruments are available. There is no "gold standard" for assessing shoulder function outcome in the general population.
MIRO Calibration Switch Mechanism
NASA Technical Reports Server (NTRS)
Suchman, Jason; Salinas, Yuki; Kubo, Holly
2001-01-01
The Jet Propulsion Laboratory has designed, analyzed, built, and tested a calibration switch mechanism for the MIRO instrument on the ROSETTA spacecraft. MIRO is the Microwave Instrument for the Rosetta Orbiter; this instrument hopes to investigate the origin of the solar system by studying the origin of comets. Specifically, the instrument will be the first to use submillimeter and millimeter wave heterodyne receivers to remotely examine the P-54 Wirtanen comet. In order to calibrate the instrument, it needs to view a hot and cold target. The purpose of the mechanism is to divert the instrument's field of view from the hot target, to the cold target, and then back into space. This cycle is to be repeated every 30 minutes for the duration of the 1.5 year mission. The paper describes the development of the mechanism, as well as analysis and testing techniques.
Dieppe, Paul
2016-01-01
Objective Investigators within many disciplines are using measures of well-being, but it is not always clear what they are measuring, or which instruments may best meet their objectives. The aims of this review were to: systematically identify well-being instruments, explore the variety of well-being dimensions within instruments and describe how the production of instruments has developed over time. Design Systematic searches, thematic analysis and narrative synthesis were undertaken. Data sources MEDLINE, EMBASE, EconLit, PsycINFO, Cochrane Library and CINAHL from 1993 to 2014 complemented by web searches and expert consultations through 2015. Eligibility criteria Instruments were selected for review if they were designed for adults (≥18 years old), generic (ie, non-disease or context specific) and available in an English version. Results A total of 99 measures of well-being were included, and 196 dimensions of well-being were identified within them. Dimensions clustered around 6 key thematic domains: mental well-being, social well-being, physical well-being, spiritual well-being, activities and functioning, and personal circumstances. Authors were rarely explicit about how existing theories had influenced the design of their tools; however, the 2 most referenced theories were Diener's model of subjective well-being and the WHO definition of health. The period between 1990 and 1999 produced the greatest number of newly developed well-being instruments (n=27). An illustration of the dimensions identified and the instruments that measure them is provided within a thematic framework of well-being. Conclusions This review provides researchers with an organised toolkit of instruments, dimensions and an accompanying glossary. The striking variability between instruments supports the need to pay close attention to what is being assessed under the umbrella of ‘well-being’ measurement. PMID:27388349
An approach to instrument qualified visual range
NASA Astrophysics Data System (ADS)
Courtade, Benoît; Bonnet, Jordan; Woodruff, Chris; Larson, Josiah; Giles, Andrew; Sonde, Nikhil; Moore, C. J.; Schimon, David; Harris, David Money; Pond, Duane; Way, Scott
2008-04-01
This paper describes a system that calculates aircraft visual range with instrumentation alone. A unique message is encoded using modified binary phase shift keying and continuously flashed at high speed by ALSF-II runway approach lights. The message is sampled at 400 frames per second by an aircraft borne high-speed camera. The encoding is designed to avoid visible flicker and minimize frame rate. Instrument qualified visual range is identified as the largest distance at which the aircraft system can acquire and verify the correct, runway-specific signal. Scaled testing indicates that if the system were implemented on one full ALSF-II fixture, instrument qualified range could be established at 5 miles in clear weather conditions.
A four mirror anastigmat collimator design for optical payload calibration
NASA Astrophysics Data System (ADS)
Rolt, Stephen; Calcines, Ariadna; Lomanowski, Bart A.; Bramall, David G.
2016-07-01
We present here a four mirror anastigmatic optical collimator design intended for the calibration of an earth observation satellite instrument. Specifically, the collimator is to be applied to the ground based calibration of the Sentinel-4/UVN instrument. This imaging spectrometer instrument itself is expected to be deployed in 2019 in a geostationary orbit and will make spatially resolved spectroscopic measurements of atmospheric contaminants. The collimator is to be deployed during the ground based calibration only and does not form part of the instrument itself. The purpose of the collimator is to provide collimated light within the two instrument passbands in the UV-VIS (305 - 500 nm) and the NIR (750 - 775 nm). Moreover, that collimated light will be derived from a variety of slit like objects located at the input focal (object) plane of the collimator which is uniformly illuminated by a number of light sources. The collimator must relay these objects with exceptionally high fidelity. To this end, the wavefront error of the collimator should be less than 30 nm rms across the collimator field of view. This field is determined by the largest object which is a large rectangular slit, 4.4° x 0.25°. Other important considerations affecting the optical design are the requirements for input telecentricity and the size (85 mm) and location (2500 mm `back focal distance') of the exit pupil. The design of the instrument against these basic requirements is discussed in detail. In addition an analysis of the straylight and tolerancing is presented in detail.
Design of affordable and ruggedized biomedical devices using virtual instrumentation.
Mathern, Ryan Michael; Schopman, Sarah; Kalchthaler, Kyle; Mehta, Khanjan; Butler, Peter
2013-05-01
Abstract This paper presents the designs of four low-cost and ruggedized biomedical devices, including a blood pressure monitor, thermometer, weighing scale and spirometer, designed for the East African context. The design constraints included a mass-production price point of $10, accuracy and precision comparable to commercial devices and ruggedness to function effectively in the harsh environment of East Africa. The blood pressure device, thermometer and weighing scale were field-tested in Kenya and each recorded data within 6% error of the measurements from commercial devices and withstood the adverse climate and rough handling. The spirometer functioned according to specifications, but a re-design is needed to improve operability and usability by patients. This article demonstrates the feasibility of designing and commercializing virtual instrumentation-based biomedical devices in resource-constrained environments through context-driven design. The next steps for the devices include designing them such that they can be more easily manufactured, use standardized materials, are easily calibrated in the field and have more user-friendly software programs that can be updated remotely.
Oliveira, M R; Schwartz, I; Costa, L S; Maia, H; Ribeiro, M; Guerreiro, L B; Acosta, A; Rocha, N S
2018-01-15
To describe the perceptions of patients, their caregivers, and their healthcare providers to the development of a new specific instrument for assessment of the quality of life (QoL) in patients with mucopolysaccharidoses (MPS) using a qualitative focus group (FG) design. FGs were held in two Brazilian states (Rio Grande do Sul and Rio de Janeiro). Three versions of the new instrument were developed, each for a different age group: children (age 8-12 years), adolescents (age 13-17), and adults (age ≥ 18). The FGs mostly confirmed the relevance of items. All FGs unanimously agreed on the facets: School, Happiness, Life Prospects, Religiosity, Pain, Continuity of Treatment, Trust in Treatment, Relationship with Family, Relationship with Healthcare Providers, Acceptance, and Meaning of Life. The overall concept of QoL (as proposed by the WHO-World Health Organization) and its facets apply to this patient population. However, other specific facets-particularly concerning clinical manifestations and the reality of the disease-were suggested, confirming the need for the development of a specific QoL instrument for MPS.
NASA Technical Reports Server (NTRS)
Brodsky, Alexander; Segal, Victor E.
1999-01-01
The EOSCUBE constraint database system is designed to be a software productivity tool for high-level specification and efficient generation of EOSDIS and other scientific products. These products are typically derived from large volumes of multidimensional data which are collected via a range of scientific instruments.
The Application Design of Solar Radio Spectrometer Based on FPGA
NASA Astrophysics Data System (ADS)
Du, Q. F.; Chen, R. J.; Zhao, Y. C.; Feng, S. W.; Chen, Y.; Song, Y.
2017-10-01
The Solar radio spectrometer is the key instrument to observe solar radio. By programing the computer software, we control the AD signal acquisition card which is based on FPGA to get a mass of data. The data are transferred by using PCI-E port. This program has realized the function of timing data collection, finding data in specific time and controlling acquisition meter in real time. It can also map the solar radio power intensity graph. By doing the experiment, we verify the reliability of solar radio spectrum instrument, in the meanwhile, the instrument simplifies the operation in observing the sun.
Compact, Passively Q-Switched Nd:YAG Laser for the MESSENGER Mission to the Planet Mercury
NASA Technical Reports Server (NTRS)
Krebs, Danny J.; Novo-Gradac, Anne-Marie; Li, Steven X.; Lindauer, Steven J.; Afzal, Robert S.; Yu, Antony
2004-01-01
A compact, passively Q-switched Nd:YAG laser has been developed for the Mercury Laser Altimeter (MLA) instrument which is an instrument on the MESSENGER mission to the planet Mercury. The laser achieves 5.4 percent efficiency with a near diffraction limited beam. It has passed all space flight environmental tests at system, instrument, and satellite integration. The laser design draws on a heritage of previous laser altimetry missions, specifically ISESAT and Mars Global Surveyor; but incorporates thermal management features unique to the requirements of an orbit of the planet Mercury.
Study of Air Pollution from Space Using TOMS: Challenges and Promises for Future Missions
NASA Technical Reports Server (NTRS)
Bhartia, Pawan K.
2002-01-01
A series of TOMS instruments built by NASA has flown on US, Russian, and Japanese satellites in the last 24 years. These instruments are well known for producing spectacular maps of the ozone hole that forms over Antarctica each spring. However, it is less well known that these instruments also provided first evidence that space-based measurements in UV of sufficiently high precision and accuracy can provide valuable information to study global air quality. We will use the TOMS experience to highlight the promises and challenges of future space-based missions designed specifically for air quality studies.
Instrument control software requirement specification for Extremely Large Telescopes
NASA Astrophysics Data System (ADS)
Young, Peter J.; Kiekebusch, Mario J.; Chiozzi, Gianluca
2010-07-01
Engineers in several observatories are now designing the next generation of optical telescopes, the Extremely Large Telescopes (ELT). These are very complex machines that will host sophisticated astronomical instruments to be used for a wide range of scientific studies. In order to carry out scientific observations, a software infrastructure is required to orchestrate the control of the multiple subsystems and functions. This paper will focus on describing the considerations, strategies and main issues related to the definition and analysis of the software requirements for the ELT's Instrument Control System using modern development processes and modelling tools like SysML.
Attention to gender in communication skills assessment instruments in medical education: a review.
Dielissen, Patrick; Bottema, Ben; Verdonk, Petra; Lagro-Janssen, Toine
2011-03-01
Gender is increasingly regarded as an important factor in doctor-patient communication education. This review aims to assess if and how gender is addressed by current assessment instruments for communication skills in medical education. In 2009 at Radboud University Nijmegen Medical Centre, an online search was conducted in the bibliographic databases PubMed, PsycINFO and ERIC for references about communication skills assessment instruments designed to be completed by trained faculty staff and used in medical education. The search strategy used the following search terms: 'consultation skills'; 'doctor-patient communication'; 'physician-patient relations'; 'medical education'; 'instruments'; 'measurement', and 'assessment'. Papers published between January 1999 and June 2009 were included. The assessment instruments identified were analysed for gender-specific content. The search yielded 21 communication skills assessment instruments. Only two of the 17 checklists obtained explicitly considered gender as a communication-related issue. Only six of 21 manuals considered gender in any way and none gave specific details to explain which aspects of communication behaviour should be assessed with regard to gender. Very few communication assessment instruments in medical education focus on gender. Nevertheless, interest exists in using gender in communication skills assessment. The criteria for and purpose of assessing gender in communication skills in medical education are yet to be clarified. © Blackwell Publishing Ltd 2011.
Kaur, Gagan Deep
2017-05-01
The design process in Kashmiri carpet weaving is distributed over a number of actors and artifacts and is mediated by a weaving notation called talim. The script encodes entire design in practice-specific symbols. This encoded script is decoded and interpreted via design-specific conventions by weavers to weave the design embedded in it. The cognitive properties of this notational system are described in the paper employing cognitive dimensions (CDs) framework of Green (People and computers, Cambridge University Press, Cambridge, 1989) and Blackwell et al. (Cognitive technology: instruments of mind-CT 2001, LNAI 2117, Springer, Berlin, 2001). After introduction to the practice, the design process is described in 'The design process' section which includes coding and decoding of talim. In 'Cognitive dimensions of talim' section, after briefly discussing CDs framework, the specific cognitive dimensions possessed by talim are described in detail.
40 CFR 86.312-79 - Dynamometer and engine equipment specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... test stand and other instruments for measurement of power output shall be accurate to within 2 percent... system must have a single tail pipe. For engines designed for a dual exhaust system, a standard or...
46 CFR 162.050-33 - Bilge alarm: Design specification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... to re-zero the instrument. The accuracy of the readings must at all times remain within the limits...) Each bilge alarm must activate its alarm whenever clean water is used for cleaning or zeroing purposes...
46 CFR 162.050-33 - Bilge alarm: Design specification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... to re-zero the instrument. The accuracy of the readings must at all times remain within the limits...) Each bilge alarm must activate its alarm whenever clean water is used for cleaning or zeroing purposes...
46 CFR 162.050-33 - Bilge alarm: Design specification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... to re-zero the instrument. The accuracy of the readings must at all times remain within the limits...) Each bilge alarm must activate its alarm whenever clean water is used for cleaning or zeroing purposes...
Rode, Julian; Wittmer, Heidi; Emerton, Lucy; Schröter-Schlaack, Christoph
2016-09-01
Economic instruments that promise "win-win" solutions for both biodiversity conservation and human livelihoods have become increasingly popular over recent years. There however remains a gap in terms of practical and policy-relevant guidance about appropriate approaches that take into account the local needs and the specific cultural, legal, and ecological context in which such instruments are being developed and applied. This paper presents a step-by-step framework that helps conservation and development planners and practitioners to identify economic instruments that can promote pro-conservation behaviour in a specific setting. The concept of 'ecosystem service opportunities' builds on, and brings together, general economic principles and an ecosystem services perspective. The framework was designed to also address a number of concerns regarding economic approaches in order to help practitioners recognise the potentials and limits of economic approaches to nature conservation. The framework is illustrated by its application within the realm of a biodiversity conservation project in Thailand.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashby, H.A.; Carlson, T.R.; Husson, L.
1986-01-01
Significant reductions in motor vehicle emissions are possible through the implementation of inspection and maintenance (I/M) programs. However, the potential benefits of I/M are obviously not achieved when specific inspection requirements are ignored or improperly performed. In addition, I/M benefits may be substantially reduced when improper repair procedures are used on vehicles which fail the test. In order for the ''theoretical'' benefits of I/M to be achieved, certain program design and enforcement procedures are necessary. The use of instrumentation and data analysis methods capable of identifying individuals who are improperly performing inspections and repairs is critical.
The stringing of Italian keyboard instruments c.1500- c.1650. Part One: Discussion and bibliography
NASA Astrophysics Data System (ADS)
Wraight, Ralph Denzil
1997-12-01
The problem of deciding which stringing materials were used on Italian string keyboard instruments is approached in two ways, by examination of documentary evidence and through the evidence of the instruments. Information on 748 instruments is presented in a catalogue which examines and describes the original condition. 89 new attributions of instruments are presented. From this comprehensive pool of information on the compasses and string lengths of the instruments made it is argued that previous authors worked with too little information to enable accurate conclusions to be drawn. Documentary evidence alone is held to be inconclusive in showing which string material was used for particular instruments at specific periods, and not as useful as argued by some previous authors. The scaling design of instruments is considered and conclusions are advanced that most virginals were designed to be strung with iron wire. It is also argued that most 16th-century harpsichords were intended to be strung with iron wire. A change to brass- scaled designs took place from about 1600-1650, and this also coincided with a loss of popularity of designs employing a 4' stop. The orientation of the first and last notes of Italian compasses on c and f notes is argued to be a consequence of music theory and not a sure indication of pitch level. There were some 16th-century harpsichords made for a pitch a fourth lower than other 8' instruments, but it is argued that there were not two groups a fourth apart in pitch. The string lengths used in the cities of Venice, Florence, Rome, Milan, and Naples are listed and show that a normal 8' range covering a whole tone was in use in all areas at various times. The evidence of the string lengths suggests that instrument makers organised the pitches of instruments into 1/3 tone steps, a scheme which may be related to the apparent use of a 1/3 comma meantone tuning system in an organ of 1494 and clavichord of 1543, before it was described in print by Zarlino in 1571.
NASA Technical Reports Server (NTRS)
Schepis, Joseph; Woodard, Timothy; Hakun, Claef; Bergandy, Konrad; Church, Joseph; Ward, Peter; Lee, Michael; Conti, Alfred; Guzek, Jeffrey
2018-01-01
A high precision, high-resolution Ocean Color Imaging (OCI) instrument is under development for the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission which requires a pair of medium speed mechanisms to scan the ocean surface continuously. The design of the rotating telescope (RT) mechanism operating at 360 RPM and the half-angle mirror (HAM) mechanism synchronized at 180 RPM was concern for maintaining pointing precision over the required life and continuous operations. An effort was undertaken with the manufacturer to design and analyze a special bearing configuration to minimize axial and radial runout, minimize torque, and maintain nominal contact stresses and stiffness over the operating temperature range and to maximize life. The bearing design, development effort, analysis and testing will be discussed as will the technical challenges that this specific design imposed upon the mechanism engineers. Bearing performance, runout as achieved and verified during encoder installation and operating torque will be described.
The Ultraviolet Spectrograph on NASA's Juno Mission
NASA Astrophysics Data System (ADS)
Gladstone, G. Randall; Persyn, Steven C.; Eterno, John S.; Walther, Brandon C.; Slater, David C.; Davis, Michael W.; Versteeg, Maarten H.; Persson, Kristian B.; Young, Michael K.; Dirks, Gregory J.; Sawka, Anthony O.; Tumlinson, Jessica; Sykes, Henry; Beshears, John; Rhoad, Cherie L.; Cravens, James P.; Winters, Gregory S.; Klar, Robert A.; Lockhart, Walter; Piepgrass, Benjamin M.; Greathouse, Thomas K.; Trantham, Bradley J.; Wilcox, Philip M.; Jackson, Matthew W.; Siegmund, Oswald H. W.; Vallerga, John V.; Raffanti, Rick; Martin, Adrian; Gérard, J.-C.; Grodent, Denis C.; Bonfond, Bertrand; Marquet, Benoit; Denis, François
2017-11-01
The ultraviolet spectrograph instrument on the Juno mission (Juno-UVS) is a long-slit imaging spectrograph designed to observe and characterize Jupiter's far-ultraviolet (FUV) auroral emissions. These observations will be coordinated and correlated with those from Juno's other remote sensing instruments and used to place in situ measurements made by Juno's particles and fields instruments into a global context, relating the local data with events occurring in more distant regions of Jupiter's magnetosphere. Juno-UVS is based on a series of imaging FUV spectrographs currently in flight—the two Alice instruments on the Rosetta and New Horizons missions, and the Lyman Alpha Mapping Project on the Lunar Reconnaissance Orbiter mission. However, Juno-UVS has several important modifications, including (1) a scan mirror (for targeting specific auroral features), (2) extensive shielding (for mitigation of electronics and data quality degradation by energetic particles), and (3) a cross delay line microchannel plate detector (for both faster photon counting and improved spatial resolution). This paper describes the science objectives, design, and initial performance of the Juno-UVS.
A novel design for steerable instruments based on laser-cut nitinol.
Dewaele, Frank; Kalmar, Alain F; De Ryck, Frederic; Lumen, Nicolaas; Williams, Leonie; Baert, Edward; Vereecke, Hugo; Kalala Okito, Jean Pierre; Mabilde, Cyriel; Blanckaert, Bart; Keereman, Vincent; Leybaert, Luc; Van Nieuwenhove, Yves; Caemaert, Jacques; Van Roost, Dirk
2014-06-01
Omnidirectional articulated instruments enhance dexterity. In neurosurgery, for example, the simultaneous use of 2 instruments through the same endoscopic shaft remains a difficult feat. It is, however, very challenging to manufacture steerable instruments of the requisite small diameter. We present a new technique to produce such instruments by means of laser cutting. Only 3 coaxial tubes are used. The middle tube has a cutting pattern that allows the steering forces to be transmitted from the proximal to the distal end. In this way the steering part is concealed in the wall of the tube. Large diameter articulated instruments such as for laparoscopy might benefit from the excellent tip stability provided by the same economical technology. Coaxial nitinol tubes are laser-cut with a Rofin Stent Cutter in a specific pattern. The 3 tubes are assembled by sliding them over one another, forming a single composite tube. In a surgical simulator, the neurosurgical microinstruments and laparoscopic needle drivers were evaluated on surgical convenience. Simultaneous use of 2 neurosurgical instruments (1.5 mm diameter) through the same endoscopic shaft proved to be very intuitive. The tip of the steerable laparoscopic instruments (10 mm diameter) could resist a lateral force of more than 20 N. The angle of motion for either instrument was at least 70° in any direction. A new design for steerable endoscopic instruments is presented. It allows the construction in a range from microinstruments to 10-mm laparoscopic devices with excellent tip stability. © The Author(s) 2013.
NASA Technical Reports Server (NTRS)
Shelfer, T. D.; Morris, Richard V.; Nguyen, T.; Agresti, D. G.; Wills, E. L.
1994-01-01
We have developed a four-detector research-grade backscatter Moessbauer spectrometer (BaMS) instrument with low resolution x-ray fluorescence analysis (XRF) capability. A flight-qualified instrument based on this design would be suitable for use on missions to the surfaces of solid solar-system objects (Moon, Mars, asteroids, etc.). Target specifications for the flight instrument are as follows: mass less than 500 g; volumes less than 300 cu cm; and power less than 2 W. The BaMS/XRF instrument would provide data on the oxidation state of iron and its distribution among iron-bearing mineralogies and elemental composition information. This data is a primary concern for the characterization of extraterrestrial surface materials.
Conceptual design of a stray light facility for Earth observation satellites
NASA Astrophysics Data System (ADS)
Stockman, Y.; Hellin, M. L.; Marcotte, S.; Mazy, E.; Versluys, J.; François, M.; Taccola, M.; Zuccaro Marchi, A.
2017-11-01
With the upcoming of TMA or FMA (Three or Four Mirrors Anastigmat) telescope design in Earth Observation system, stray light is a major contributor to the degradation of the image quality. Numerous sources of stray light can be identified and theoretically evaluated. Nevertheless in order to build a stray light model of the instrument, the Point Spread Function(s) of the instrument, i.e., the flux response of the instrument to the flux received at the instrument entrance from an infinite distant point source needs to be determined. This paper presents a conceptual design of a facility placed in a vacuum chamber to eliminate undesired air particles scatter light sources. The specification of the clean room class or vacuum will depend on the required rejection to be measured. Once the vacuum chamber is closed, the stray light level from the external environment can be considered as negligible. Inside the chamber a dedicated baffle design is required to eliminate undesired light generated by the set up itself e.g. retro reflected light away from the instrument under test. This implies blackened shrouds all around the specimen. The proposed illumination system is a 400 mm off axis parabolic mirror with a focal length of 2 m. The off axis design suppresses the problem of stray light that can be generated by the internal obstruction. A dedicated block source is evaluated in order to avoid any stray light coming from the structure around the source pinhole. Dedicated attention is required on the selection of the source to achieve the required large measurement dynamic.
New pediatric vision screener, part II: electronics, software, signal processing and validation.
Gramatikov, Boris I; Irsch, Kristina; Wu, Yi-Kai; Guyton, David L
2016-02-04
We have developed an improved pediatric vision screener (PVS) that can reliably detect central fixation, eye alignment and focus. The instrument identifies risk factors for amblyopia, namely eye misalignment and defocus. The device uses the birefringence of the human fovea (the most sensitive part of the retina). The optics have been reported in more detail previously. The present article focuses on the electronics and the analysis algorithms used. The objective of this study was to optimize the analog design, data acquisition, noise suppression techniques, the classification algorithms and the decision making thresholds, as well as to validate the performance of the research instrument on an initial group of young test subjects-18 patients with known vision abnormalities (eight male and 10 female), ages 4-25 (only one above 18) and 19 controls with proven lack of vision issues. Four statistical methods were used to derive decision making thresholds that would best separate patients with abnormalities from controls. Sensitivity and specificity were calculated for each method, and the most suitable one was selected. Both the central fixation and the focus detection criteria worked robustly and allowed reliable separation between normal test subjects and symptomatic subjects. The sensitivity of the instrument was 100 % for both central fixation and focus detection. The specificity was 100 % for central fixation and 89.5 % for focus detection. The overall sensitivity was 100 % and the overall specificity was 94.7 %. Despite the relatively small initial sample size, we believe that the PVS instrument design, the analysis methods employed, and the device as a whole, will prove valuable for mass screening of children.
THOR Ion Mass Spectrometer instrument - IMS
NASA Astrophysics Data System (ADS)
Retinò, Alessandro; Kucharek, Harald; Saito, Yoshifumi; Fraenz, Markus; Verdeil, Christophe; Leblanc, Frederic; Techer, Jean-Denis; Jeandet, Alexis; Macri, John; Gaidos, John; Granoff, Mark; Yokota, Shoichiro; Fontaine, Dominique; Berthomier, Matthieu; Delcourt, Dominique; Kistler, Lynn; Galvin, Antoniette; Kasahara, Satoshi; Kronberg, Elena
2016-04-01
Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. Specifically, THOR will study how turbulent fluctuations at kinetic scales heat and accelerate particles in different turbulent environments within the near-Earth space. To achieve this goal, THOR payload is being designed to measure electromagnetic fields and particle distribution functions with unprecedented resolution and accuracy. Here we present the Ion Mass Spectrometer (IMS) instrument that will measure the full three-dimensional distribution functions of near-Earth main ion species (H+, He+, He++ and O+) at high time resolution (~ 150 ms for H+ , ~ 300 ms for He++) with energy resolution down to ~ 10% in the range 10 eV/q to 30 keV/q and angular resolution ~ 10°. Such high time resolution is achieved by mounting multiple sensors around the spacecraft body, in similar fashion to the MMS/FPI instrument. Each sensor combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCP) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification, discrimination and time-to-digital conversion (TDC). IMS is being designed to address many of THOR science requirements, in particular ion heating and acceleration by turbulent fluctuations in foreshock, shock and magnetosheath regions. The IMS instrument is being designed and will be built by an international consortium of scientific institutes with main hardware contributions from France, USA, Japan and Germany.
NASA Astrophysics Data System (ADS)
Schmidt, Luke M.; Ribeiro, Rafael; Taylor, Keith; Jones, Damien; Prochaska, Travis; DePoy, Darren L.; Marshall, Jennifer L.; Cook, Erika; Froning, Cynthia; Ji, Tae-Geun; Lee, Hye-In; Mendes de Oliveira, Claudia; Pak, Soojong; Papovich, Casey
2016-08-01
We present a preliminary conceptual optical design for GMACS, a wide field, multi-object, optical spectrograph currently being developed for the Giant Magellan Telescope (GMT). We include details of the optical design requirements derived from the instrument scientific and technical objectives and demonstrate how these requirements are met by the current design. Detector specifications, field acquisition/alignment optics, and optical considerations for the active flexure control system are also discussed.
Solar-B X-ray Telescope (XRT) Concept Study Report
NASA Astrophysics Data System (ADS)
Golub, Leon
1999-10-01
The X-ray observations from the Yohkoh SXT provided the greatest step forward in our understanding of the solar corona in nearly two decades. Expanding on the accomplishments of Yohkoh, we believe that the scientific objectives of the Solar-B mission are achieved with a significantly improved X-ray telescope (XRT) similar to the SXT. The Solar-B XRT will have twice the spatial resolution and a broader temperature response, while building on the knowledge gained from the successful Yohkoh mission. We present the scientific justification for this view, discuss the instrumental requirements that flow from the scientific objectives, and describe the instrumentation to meet these requirements. We then provide a detailed discussion of the design activities carried out during Phase A, noting the conclusions that were reached in terms of their implications for the detailed design activities which are now commencing. Details of the instrument that have changed as a result of the Phase A studied are specifically noted, and areas of concern going into Phase B are highlighted. XRT is a grazing-incidence (GI) modified Wolter I X-ray telescope, of 35cm inner diameter and 2.7m focal length. The 2048x2048 back-illuminated CCD (now an ISAS responsibility) has 13.5 micron pixels, corresponding to 1.0 arcsec and giving full Sun field of view. This will be the highest resolution GI X-ray telescope ever flown for Solar coronal studies, and it has been designed specifically to observe both the high and low temperature coronal plasma. A small optical telescope provides visible light images for co-alignment with the Solar-B optical and EUV instruments. The XRT science team is working in close cooperation with our Japanese colleagues in the design and construction of this instrument. All of the expertise and resources of the High Energy and Solar/Stellar Divisions of the Center for Astrophysics are being made available to this program, and our team will carry its full share of responsibility for mission operations, data reduction and education and public outreach. All aspects of the XRT design were reviewed during Phase A. The study focussed particularly on those aspects that have the greatest affect on instrument performance and extended lifetime, on the image quality error budget, and on the camera (mechanical and electrical) interface and the instrument mounting interfaces. The present instrument design differs in some details from that originally proposed. Selection of the XRT for Phase A study was contingent upon the removal of the camera and its associated electronics, and the acceptance of a stringent cost cap. The removal of the electronics left the XRT without control electronics for the instrument mechanisms. A mechanism controller was therefore added. The removal of the camera resulted in major complications to the integration and test plan. After many discussions, it was decided that the system would be less expensive, and the risk of unacceptable performance lower, if we include a focus mechanism. The remainder of the XRT design baseline matches the proposed configuration. Data requirements for the XRT are driven by the science plans, which are based on the physical processes in the solar outer atmosphere. Discussions to date of the XRT observing plan, both alone and in conjunction with the other Solar-B instruments, shows that the XRT needs 2 Gbits of on-board storage, at least one circulating buffer of 640 Mbits, and twelve 10- minute downlinks per day in order to carry out its required programs.
Solar-B X-ray Telescope (XRT) Concept Study Report
NASA Technical Reports Server (NTRS)
Golub, Leon
1999-01-01
The X-ray observations from the Yohkoh SXT provided the greatest step forward in our understanding of the solar corona in nearly two decades. Expanding on the accomplishments of Yohkoh, we believe that the scientific objectives of the Solar-B mission are achieved with a significantly improved X-ray telescope (XRT) similar to the SXT. The Solar-B XRT will have twice the spatial resolution and a broader temperature response, while building on the knowledge gained from the successful Yohkoh mission. We present the scientific justification for this view, discuss the instrumental requirements that flow from the scientific objectives, and describe the instrumentation to meet these requirements. We then provide a detailed discussion of the design activities carried out during Phase A, noting the conclusions that were reached in terms of their implications for the detailed design activities which are now commencing. Details of the instrument that have changed as a result of the Phase A studied are specifically noted, and areas of concern going into Phase B are highlighted. XRT is a grazing-incidence (GI) modified Wolter I X-ray telescope, of 35cm inner diameter and 2.7m focal length. The 2048x2048 back-illuminated CCD (now an ISAS responsibility) has 13.5 micron pixels, corresponding to 1.0 arcsec and giving full Sun field of view. This will be the highest resolution GI X-ray telescope ever flown for Solar coronal studies, and it has been designed specifically to observe both the high and low temperature coronal plasma. A small optical telescope provides visible light images for co-alignment with the Solar-B optical and EUV instruments. The XRT science team is working in close cooperation with our Japanese colleagues in the design and construction of this instrument. All of the expertise and resources of the High Energy and Solar/Stellar Divisions of the Center for Astrophysics are being made available to this program, and our team will carry its full share of responsibility for mission operations, data reduction and education and public outreach. All aspects of the XRT design were reviewed during Phase A. The study focussed particularly on those aspects that have the greatest affect on instrument performance and extended lifetime, on the image quality error budget, and on the camera (mechanical and electrical) interface and the instrument mounting interfaces. The present instrument design differs in some details from that originally proposed. Selection of the XRT for Phase A study was contingent upon the removal of the camera and its associated electronics, and the acceptance of a stringent cost cap. The removal of the electronics left the XRT without control electronics for the instrument mechanisms. A mechanism controller was therefore added. The removal of the camera resulted in major complications to the integration and test plan. After many discussions, it was decided that the system would be less expensive, and the risk of unacceptable performance lower, if we include a focus mechanism. The remainder of the XRT design baseline matches the proposed configuration. Data requirements for the XRT are driven by the science plans, which are based on the physical processes in the solar outer atmosphere. Discussions to date of the XRT observing plan, both alone and in conjunction with the other Solar-B instruments, shows that the XRT needs 2 Gbits of on-board storage, at least one circulating buffer of 640 Mbits, and twelve 10- minute downlinks per day in order to carry out its required programs.
Subminiaturization for ERAST instrumentation (Environmental Research Aircraft and Sensor Technology)
NASA Technical Reports Server (NTRS)
Madou, Marc; Lowenstein, Max; Wegener, Steven
1995-01-01
We are focusing on the Argus as an example to demonstrate our philosophy on miniaturization of airborne analytical instruments for the study of atmospheric chemistry. Argus is a two channel, tunable-diode laser absorption spectrometer developed at NASA for the measurement of nitrogen dioxide (N2O) (4.5 micrometers) and ammonia (CH3) (3.3 micrometers) at the 0.1 parts per billion (ppb) level from the Perseus aircraft platform at altitudes up to 30 km. Although Argus' mass is down to 23 kg from the 197 kg Atlas, its predecessor, our goal is to design a next-generation subminiaturized instrument weighing less than 1 kg, measuring a few cm(exp 3) and able to eliminate dewars for cooling. Current designs enable use to make a small,inexpensive, monolithic spectrometer without the required sensitivity range. Further work is on its way to increase sensitivity. We are continuing to zero-base the technical approach in terms of the specifications for the given instrument. We are establishing a check list of questions to hone into the best micromachining approach and to superpose on the answers insights in scaling laws and flexible engineering designs to enable more relaxed tolerances for the smallest of the components.
NASA Technical Reports Server (NTRS)
Hess, R. A.
1976-01-01
Paramount to proper utilization of electronic displays is a method for determining pilot-centered display requirements. Display design should be viewed fundamentally as a guidance and control problem which has interactions with the designer's knowledge of human psychomotor activity. From this standpoint, reliable analytical models of human pilots as information processors and controllers can provide valuable insight into the display design process. A relatively straightforward, nearly algorithmic procedure for deriving model-based, pilot-centered display requirements was developed and is presented. The optimal or control theoretic pilot model serves as the backbone of the design methodology, which is specifically directed toward the synthesis of head-down, electronic, cockpit display formats. Some novel applications of the optimal pilot model are discussed. An analytical design example is offered which defines a format for the electronic display to be used in a UH-1H helicopter in a landing approach task involving longitudinal and lateral degrees of freedom.
Randol, B M; Ebert, R W; Allegrini, F; McComas, D J; Schwadron, N A
2010-11-01
Electrostatic analyzers (ESAs), in various forms, are used to measure plasma in a range of applications. In this article, we describe how ions reflect from the interior surfaces of an ESA, the detection of which constitutes a fundamentally nonideal response of ESAs. We demonstrate this effect by comparing laboratory data from a real ESA-based space instrument, the Solar Wind Around Pluto (SWAP) instrument, aboard the NASA New Horizons spacecraft, to results from a model based on quantum mechanical simulations of particles reflected from the instrument's surfaces combined with simulations of particle trajectories through the instrument's applied electrostatic fields. Thus, we show, for the first time, how reflected ions in ESAs lead to nonideal effects that have important implications for understanding the data returned by these instruments, as well as for designing new low-background ESA-based instruments. Specifically, we show that the response of SWAP widens considerably below a level of 10(-3) of the peak response. Thus, a direct measurement of a plasma distribution with SWAP will have an energy-dependent background on the order of ≤10(-3) of the peak of the signal due to that distribution. We predict that this order of magnitude estimate for the background applies to a large number of ESA-based instruments because ESAs operate using a common principle. However, the exact shape of the energy-dependent response will be different for different instruments. The principle of operation is that ions outside the ideal range of energy-per-charge are deflected into the walls of the ESA. Therefore, we propose that a new design paradigm is necessary to mitigate the effect of ion reflections and thus accurately and directly measure the energy spectrum of a plasma using ESAs. In this article, we build a framework for minimizing the effect of ion reflections in the design of new ESAs. Through the use of existing computer simulation software, a design team can use our method to quantify the amount of reflections in their instrument and iteratively change design parameters before fabrication, conserving resources. A possible direction for the new design paradigm is having nonsolid walls of the ESA, already used in some applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randol, B. M.; Ebert, R. W.; Space Science and Engineering Division, Southwest Research Institute, San Antonio, Texas 78228
Electrostatic analyzers (ESAs), in various forms, are used to measure plasma in a range of applications. In this article, we describe how ions reflect from the interior surfaces of an ESA, the detection of which constitutes a fundamentally nonideal response of ESAs. We demonstrate this effect by comparing laboratory data from a real ESA-based space instrument, the Solar Wind Around Pluto (SWAP) instrument, aboard the NASA New Horizons spacecraft, to results from a model based on quantum mechanical simulations of particles reflected from the instrument's surfaces combined with simulations of particle trajectories through the instrument's applied electrostatic fields. Thus, wemore » show, for the first time, how reflected ions in ESAs lead to nonideal effects that have important implications for understanding the data returned by these instruments, as well as for designing new low-background ESA-based instruments. Specifically, we show that the response of SWAP widens considerably below a level of 10{sup -3} of the peak response. Thus, a direct measurement of a plasma distribution with SWAP will have an energy-dependent background on the order of {<=}10{sup -3} of the peak of the signal due to that distribution. We predict that this order of magnitude estimate for the background applies to a large number of ESA-based instruments because ESAs operate using a common principle. However, the exact shape of the energy-dependent response will be different for different instruments. The principle of operation is that ions outside the ideal range of energy-per-charge are deflected into the walls of the ESA. Therefore, we propose that a new design paradigm is necessary to mitigate the effect of ion reflections and thus accurately and directly measure the energy spectrum of a plasma using ESAs. In this article, we build a framework for minimizing the effect of ion reflections in the design of new ESAs. Through the use of existing computer simulation software, a design team can use our method to quantify the amount of reflections in their instrument and iteratively change design parameters before fabrication, conserving resources. A possible direction for the new design paradigm is having nonsolid walls of the ESA, already used in some applications.« less
Instrument performance and simulation verification of the POLAR detector
NASA Astrophysics Data System (ADS)
Kole, M.; Li, Z. H.; Produit, N.; Tymieniecka, T.; Zhang, J.; Zwolinska, A.; Bao, T. W.; Bernasconi, T.; Cadoux, F.; Feng, M. Z.; Gauvin, N.; Hajdas, W.; Kong, S. W.; Li, H. C.; Li, L.; Liu, X.; Marcinkowski, R.; Orsi, S.; Pohl, M.; Rybka, D.; Sun, J. C.; Song, L. M.; Szabelski, J.; Wang, R. J.; Wang, Y. H.; Wen, X.; Wu, B. B.; Wu, X.; Xiao, H. L.; Xiong, S. L.; Zhang, L.; Zhang, L. Y.; Zhang, S. N.; Zhang, X. F.; Zhang, Y. J.; Zhao, Y.
2017-11-01
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
High-grade, compact spectrometers for Earth observation from SmallSats
NASA Astrophysics Data System (ADS)
van der Wal, L. F.; de Goeij, B. T. G.; Jansen, R.; Oosterling, J. A. J.; Snijders, B.
2016-10-01
The market for nano- and microsatellites is developing rapidly. There is a strong focus on 2D imaging of the Earth's surface, with limited possibilities to obtain spectral information. More demanding applications, such as monitoring trace gases, aerosols or water quality still require advanced imaging instruments, which are large, heavy and expensive. In recent years TNO has investigated and developed different innovative designs to realize advanced spectrometers for space applications in a more compact and cost-effective manner. This offers multiple advantages: a compact instrument can be flown on a much smaller platform (nano- or microsatellite); a low-cost instrument opens up the possibility to fly multiple instruments in a satellite constellation, improving both global coverage and temporal sampling (e.g. to study diurnal processes); a constellation of low-cost instruments may provide added value to the larger scientific and operational satellite missions (e.g. the Copernicus Sentinel missions); and a small, lightweight spectrometer can also be mounted easily on a high-altitude UAV (offering high spatial resolution). Last but not least, a low-cost instrument may allow to break through the `cost spiral': lower cost will allow to take more risk and thus progress more quickly. This may lead to a much faster development cycle than customary for current Earth Observation instruments. To explore the potential of a constellation of low-cost instruments a consortium of Dutch partners was formed, which currently consists of Airbus Defence and Space Netherlands, ISISpace, S and T and TNO. In this paper we will illustrate this new design approach by using the most advanced design of a hyperspectral imaging spectrometer (named `Spectrolite') as an example. We will discuss the different design and manufacturing techniques that were used to realize this compact and low-cost design. Laboratory tests as well as the first preliminary results of airborne measurements with the Spectrolite breadboard will be presented and discussed. The design of Spectrolite offers the flexibility to tune its performance (spectral range, spectral resolution) to a specific application. Thus, based on the same basic system design, Spectrolite offers a range of applications to different clients. To illustrate this, we will present a mission concept to monitor NO2 concentrations over urban areas at high spatial resolution, based on a constellation of small satellites.
Silicon-Germanium Voltage-Controlled Oscillator at 105 GHz
NASA Technical Reports Server (NTRS)
Wong, Alden; Larocca, Tim; Chang, M. Frank; Samoska, Lorene A.
2011-01-01
A group at UCLA, in collaboration with the Jet Propulsion Laboratory, has designed a voltage-controlled oscillator (VCO) created specifically for a compact, integrated, electronically tunable frequency generator useable for submillimeter- wave science instruments operating in extreme cold environments.
NASA Astrophysics Data System (ADS)
Ahlers, B.; Hutchinson, I.; Ingley, R.
2017-11-01
A spectrometer for combined Raman and Laser Induced Breakdown Spectroscopy (LIBS) is amongst the different instruments that have been pre-selected for the Pasteur payload of the ExoMars rover. It is regarded as a fundamental, next-generation instrument for organic, mineralogical and elemental characterisation of Martian soil, rock samples and organic molecules. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities [1]. The combined Raman / LIBS instrument has been recommended as the highest priority mineralogy instrument to be included in the rover's analytical laboratory for the following tasks: Analyse surface and sub-surface soil and rocks on Mars, identify organics in the search for life and determine soil origin & toxicity. The synergy of the system is evident: the Raman spectrometer is dedicated to molecular analysis of organics and minerals; the LIBS provides information on the sample's elemental composition. An international team, under ESA contract and with the leadership of TNO Science and Industry, has built and tested an Elegant Bread Board (EBB) of the combined Raman / LIBS instrument. The EBB comprises a specifically designed, extremely compact, spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. The EBB also includes lasers, illumination and imaging optics as well as fibre optics for light transfer. A summary of the functional and environmental requirements together with a description of the optical design and its expected performance are described in [2]. The EBB was developed and constructed to verify the instruments' end-to-end functional performance with natural samples. The combined Raman / LIBS EBB realisation and test results of natural samples will be presented. For the Flight Model (FM) instrument, currently in the design phase, the Netherlands will be responsible for the design, development and verification of the spectrometer unit, while the UK provides the detector. The differences between the EBB and the FM will be demonstrated.
Zaror, Carlos; Pardo, Yolanda; Espinoza-Espinoza, Gerardo; Pont, Àngels; Muñoz-Millán, Patricia; Martínez-Zapata, María José; Vilagut, Gemma; Forero, Carlos G; Garin, Olatz; Alonso, Jordi; Ferrer, Montse
2018-03-22
To obtain a systematic and standardized evaluation of the current evidence on development process, metric properties, and administration issues of oral health-related quality of life instruments available for children and adolescents. A systematic search until October 2016 was conducted in PubMed, Embase, Lilacs, SciELO, and Cochrane databases. Articles with information regarding the development process, metric properties, and administration issues of pediatric instruments measuring oral health-related quality of life were eligible for inclusion. Two researchers independently evaluated each instrument applying the Evaluating Measures of Patient-Reported Outcomes (EMPRO) tool. An overall and seven attribute-specific EMPRO scores were calculated (range 0-100, worst to best): measurement model, reliability, validity, responsiveness, interpretability, burden, and alternative forms. We identified 18 instruments evaluated in 132 articles. From five instruments designed for preschoolers, the Early Childhood Oral Health Impact Scale (ECOHIS) obtained the highest overall EMPRO score (82.2). Of nine identified for schoolchildren and adolescents, the best rated instrument was the Child Perceptions Questionnaire 11-14 (82.1). Among the four instruments developed for any age, the Family Impact Scale (FIS) obtained the highest scores (80.3). The evidence supports the use of the ECOHIS for preschoolers, while the age is a key factor when choosing among the four recommended instruments for schoolchildren and adolescents. Instruments for specific conditions, symptoms, or treatments need further research on metric properties. Our results facilitate decision-making on the correct oral health-related quality of life instrument selection for any certain study purpose and population during the childhood and adolescence life cycle.
A multi-sensor oceanographic measurement system for coastal environments
Martini, Marinna A.; Strahle, William J.
1993-01-01
An instrument system has been developed for long-term sediment transport studies that uses a modular design to combine off the shelf components into a complete and flexible package. A common data storage format is used in each instrument system so that the same hardware can be assembled in different ways to address specific scientific studies with minimal engineering support and modification. Three systems have been constructed and successfully deployed to date in two different coastal environments.
Instrumentation and Controls Division progress report for the period July 1, 1986 to June 30, 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klobe, L.E.
1988-12-01
The Instrumentation and Controls (IandC) Division of Oak Ridge National Laboratory (ORNL) performs basic and applied instrumentation and controls research, development and design engineering, specialized instrument design and fabrication, and maintenance services for instruments, electronics, and computers. The IandC Division is one of the largest RandD organizations of its type among government laboratories, and it exists as the result of an organizational strategy to integrate ORNL's instrumentation and controls-related disciplines into one dedicated functional organization to increase the Laboratory's expertise and capabilities in these rapidly expanding, innovative areas of technology. The Division participates in the programs and projects of ORNLmore » by applying its expertise and capabilities in concert with other divisions to perform basic research and mission-oriented technology development. Many of the Division's RandD tasks that are a part of a larger ORNL program are of sufficient scope that the IandC effort constitutes a separate program element with direct funding and management responsibility within the Division. The activities of IandC include performance of an RandD task in IandC facilities, the participation of from one of many IandC engineers and scientists in a multidisciplinary team working in a specific research area or development project, design and fabrication of a special instrument or instrumentation system, or a few hours of maintenance service. In its support and maintenance work, the role of the IandC Division is to provide a level of expertise appropriate to complete a job successfully at minimum overall cost and time schedule---a role which involves IandC in almost all ORNL activities.« less
Marques, Iuri; Willis, Sarah Caroline; Schafheutle, Ellen Ingrid; Hassell, Karen
2018-04-09
Purpose Organisational culture (OC) shapes individuals' perceptions and experiences of work. However, no instrument capable of measuring specific aspects of OC in community pharmacy exists. The purpose of this paper is to report the development and validation of an instrument to measure OC in community pharmacy in Great Britain (GB), and conduct a preliminary analysis of data collected using it. Design/methodology/approach Instrument development comprised three stages: Stage I: 12 qualitative interviews and relevant literature informed instrument design; Stage II: 30 cognitive interviews assessed content validity; and Stage III: a cross-sectional survey mailed to 1,000 community pharmacists in GB, with factor analysis for instrument validation. Statistical analysis investigated how community pharmacists perceived OC in their place of work. Findings Factor analysis produced an instrument containing 60 items across five OC dimensions - business and work configuration, social relationships, personal and professional development, skills utilisation, and environment and structures. Internal reliability for the dimensions was high (0.84 to 0.95); item-total correlations were adequate ( r=0.46 to r=0.76). Based on 209 responses, analysis suggests different OCs in community pharmacy, with some community pharmacists viewing the environment in which they worked as having a higher frequency of aspects related to patient contact and safety than others. Since these aspects are important for providing high healthcare standards, it is likely that differences in OC may be linked to different healthcare outcomes. Originality/value This newly developed and validated instrument to measure OC in community pharmacy can be used to benchmark existing OC across different pharmacies and design interventions for triggering change to improve outcomes for community pharmacists and patients.
Infrared Astrophysics in the SOFIA Era - An Overview
NASA Astrophysics Data System (ADS)
Yorke, Harold W.
2018-06-01
The Stratospheric Observatory for Infrared Astronomy (SOFIA) provides the international astronomical community access to a broad range of instrumentation that covers wavelengths spanning the near to far infrared. The high spectral resolution of many of these instruments in several wavelength bands is unmatched by any existing or near future planned facility. The far infrared polarization capabilities of one of its instruments, HAWC+, is also unique. Moreover, SOFIA allows for additional instrument augmentations, as new state-of-the-art photometric, spectrometric, and polarimetric capabilities have been added and are being further improved. The fact that SOFIA provides ample mass, power, computing capabilities as well as 4K cooling eases the constraints on future instrument design, technical readiness, and the instrument build to an extent not possible for space-borne missions. We will review SOFIA's current and future planned capabilities and highlight specific science areas for which the stratospheric observatory will be able to significantly advance Origins science topics.
NASA Astrophysics Data System (ADS)
Ennico, Kimberly; Shirley, Mark; Colaprete, Anthony; Osetinsky, Leonid
2012-05-01
The primary objective of the Lunar Crater Observation and Sensing Satellite (LCROSS) was to confirm the presence or absence of water ice in a permanently shadowed region (PSR) at a lunar pole. LCROSS was classified as a NASA Class D mission. Its payload, the subject of this article, was designed, built, tested and operated to support a condensed schedule, risk tolerant mission approach, a new paradigm for NASA science missions. All nine science instruments, most of them ruggedized commercial-off-the-shelf (COTS), successfully collected data during all in-flight calibration campaigns, and most importantly, during the final descent to the lunar surface on October 9, 2009, after 112 days in space. LCROSS demonstrated that COTS instruments and designs with simple interfaces, can provide high-quality science at low-cost and in short development time frames. Building upfront into the payload design, flexibility, redundancy where possible even with the science measurement approach, and large margins, played important roles for this new type of payload. The environmental and calibration approach adopted by the LCROSS team, compared to existing standard programs, is discussed. The description, capabilities, calibration and in-flight performance of each instrument are summarized. Finally, this paper goes into depth about specific areas where the instruments worked differently than expected and how the flexibility of the payload team, the knowledge of instrument priority and science trades, and proactive margin maintenance, led to a successful science measurement by the LCROSS payload's instrument complement.
A Systematic Review of Head and Neck Cancer Quality of Life Assessment Instruments
Ojo, Bukola; Genden, Eric M.; Teng, Marita S.; Milbury, Kathrin; Misiukiewicz, Krzysztof J.; Badr, Hoda
2012-01-01
Summary Although quality of life (QOL) is an important treatment outcome in head and neck cancer (HNC), cross-study comparisons have been hampered by the heterogeneity of measures used and the fact that reviews of HNC QOL instruments have not been comprehensive to date. We performed a systematic review of the published literature on HNC QOL instruments from 1990–2010, categorized, and reviewed the properties of the instruments using international guidelines as reference. Of the 2766 articles retrieved, 710 met the inclusion criteria and used 57 different head and neck-specific instruments to assess QOL. A review of the properties of these utilized measures and identification of areas in need of further research is presented. Given the volume and heterogeneity of QOL measures, there is no gold standard questionnaire. Therefore, when selecting instruments, researchers should consider not only psychometric properties but also research objectives, study design, and the pitfalls and benefits of combining different measures. Although great strides have been made in the assessment of QOL in HNC and researchers now have a plethora of quality instruments to choose from, more work is needed to improve the clinical utility of these measures in order to link QOL research to clinical practice. This review provides a platform for head and neck-specific instrument comparisons, with suggestions of important factors to consider in the systematic selection of QOL instruments, and is a first step towards translation of QOL assessment into the clinical scene. PMID:22525604
Developing a Teacher Administered Anxiety Rating Scale Suitable for Five to Seven-Year-Old Children
ERIC Educational Resources Information Center
Goulet, Joseph
2013-01-01
This paper presents results of twin studies pertinent to the development of a rating scale designed for use by teachers to identify anxious and shy children, aged 5 to 7 years, in Kindergarten and Grade One. Currently, no instruments designed specifically for this purpose exist. Children experiencing difficulty with internalizing disorders such as…
ERIC Educational Resources Information Center
Casem, Remalyn Q.
2016-01-01
This study aimed to determine the effects of flipped instruction on the performance and attitude of high school students in Mathematics. The study made use of the true experimental design, specifically the pretest-posttest control group design. There were two instruments used to gather data, the pretest-posttest which was subjected to validity and…
Design study of the deepsky ultraviolet survey telescope. [Spacelab payload
NASA Technical Reports Server (NTRS)
Page, N. A.; Callaghan, F. G.; Killen, R. H.; Willis, W.
1977-01-01
Preliminary mechanical design and specifications are presented for a wide field ultraviolet telescope and detector to be carried as a Spacelab payload. Topics discussed include support structure stiffness (torsional and bending), mirror assembly, thermal control, optical alignment, attachment to the instrument pointing pallet, control and display, power requirements, acceptance and qualification test plans, cost analysis and scheduling. Drawings are included.
ERIC Educational Resources Information Center
Francis, Leslie J.; Brockett, Adrian; Village, Andrew
2013-01-01
Alongside a family of instruments designed to measure the attitudinal dimension of religion within specific faith contexts (Christianity, Hinduism, Islam, and Judaism), the Astley-Francis Scale of Attitude toward Theistic Faith was designed to assess the attitudinal dimension of religion within a multifaith context. Drawing on a sample of 4338…
NASA Technical Reports Server (NTRS)
Leviton, Douglas B.; Tsevetanov, Zlatan; Woodruff, Bob; Mooney, Thomas A.
1998-01-01
Advanced optical bandpass filters for the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) have been developed on a filter-by-filter basis through detailed studies which take into account the instrument's science goals, available optical filter fabrication technology, and developments in ACS's charge-coupled-device (CCD) detector technology. These filters include a subset of filters for the Sloan Digital Sky Survey (SDSS) which are optimized for astronomical photometry using today's charge-coupled-devices (CCD's). In order for ACS to be truly advanced, these filters must push the state-of-the-art in performance in a number of key areas at the same time. Important requirements for these filters include outstanding transmitted wavefront, high transmittance, uniform transmittance across each filter, spectrally structure-free bandpasses, exceptionally high out of band rejection, a high degree of parfocality, and immunity to environmental degradation. These constitute a very stringent set of requirements indeed, especially for filters which are up to 90 mm in diameter. The highly successful paradigm in which final specifications for flight filters were derived through interaction amongst the ACS Science Team, the instrument designer, the lead optical engineer, and the filter designer and vendor is described. Examples of iterative design trade studies carried out in the context of science needs and budgetary and schedule constraints are presented. An overview of the final design specifications for the ACS bandpass and ramp filters is also presented.
NASA Astrophysics Data System (ADS)
de Rossi, Giuseppe; Puccini, Massimo; Puccetti, Giuseppe
1995-12-01
The paper describes the environmental tests to be carried out on the scientific instrumentation to be flown on the M-55 Geophysika in the frame of the APE Program. The instruments, developed by different European research institutes, are for remote sensing and in situ measurements of the major components of the Earth's stratosphere. The paper presents the technological activities that ENEA (Ente Nazionale per le Nuove Tecnologie l'Energia e l'Ambiente) is carrying out in its laboratories to verify the correspondence of the various instruments to meet the requirements for airborne application. The reference documents used have been the RTCA/DO-160C and the MDB (Myasishchev Design Bureau) specifications.
Progress in molecular imaging in endoscopy and endomicroscopy for cancer imaging
Khondee, Supang; Wang, Thomas D.
2014-01-01
Imaging is an essential tool for effective cancer management. Endoscopes are important medical instruments for performing in vivo imaging in hollow organs. Early detection of cancer can be achieved with surveillance using endoscopy, and has been shown to reduce mortality and to improve outcomes. Recently, great advancements have been made in endoscopic instruments, including new developments in optical designs, light sources, optical fibers, miniature scanners, and multimodal systems, allowing for improved resolution, greater tissue penetration, and multispectral imaging. In addition, progress has been made in the development of highly-specific optical probes, allowing for improved specificity for molecular targets. Integration of these new endoscopic instruments with molecular probes provides a unique opportunity for significantly improving patient outcomes and has potential to further improve early detection, image guided therapy, targeted therapy, and personalized medicine. This work summarizes current and evolving endoscopic technologies, and provides an overview of various promising optical molecular probes. PMID:23502247
In vivo Real-Time Mass Spectrometry for Guided Surgery Application
NASA Astrophysics Data System (ADS)
Fatou, Benoit; Saudemont, Philippe; Leblanc, Eric; Vinatier, Denis; Mesdag, Violette; Wisztorski, Maxence; Focsa, Cristian; Salzet, Michel; Ziskind, Michael; Fournier, Isabelle
2016-05-01
Here we describe a new instrument (SpiderMass) designed for in vivo and real-time analysis. In this instrument ion production is performed remotely from the MS instrument and the generated ions are transported in real-time to the MS analyzer. Ion production is promoted by Resonant Infrared Laser Ablation (RIR-LA) based on the highly effective excitation of O-H bonds in water molecules naturally present in most biological samples. The retrieved molecular patterns are specific to the cell phenotypes and benign versus cancer regions of patient biopsies can be easily differentiated. We also demonstrate by analysis of human skin that SpiderMass can be used under in vivo conditions with minimal damage and pain. Furthermore SpiderMass can also be used for real-time drug metabolism and pharmacokinetic (DMPK) analysis or food safety topics. SpiderMass is thus the first MS based system designed for in vivo real-time analysis under minimally invasive conditions.
Automatisms in EMIR instrument to improve operation, safety and maintenance
NASA Astrophysics Data System (ADS)
Fernández Izquierdo, Patricia; Núñez Cagigal, Miguel; Barreto Rodríguez, Roberto; Martínez Rey, Noelia; Santana Tschudi, Samuel; Barreto Cabrera, Maria; Patrón Recio, Jesús; Garzón López, Francisco
2014-08-01
EMIR is the NIR imager and multiobject spectrograph being built as a common user instrument for the 10-m class GTC. Big cryogenic instruments demand a reliable design and a specific hardware and software to increase its safety and productivity. EMIR vacuum, cooling and heating systems are monitored and partially controlled by a Programmable Logic Controller (PLC) in industrial format with a touch screen. The PLC aids the instrument operator in the maintenance tasks recovering autonomously vacuum if required or proposing preventive maintenance actions. The PLC and its associated hardware improve EMIR safety having immediate reactions against eventual failure modes in the instrument or in external supplies, including hardware failures during the heating procedure or failure in the PLC itself. EMIR PLC provides detailed information periodically about status and alarms of vacuum and cooling components or external supplies.
POLIX: A Thomson X-ray polarimeter for a small satellite mission
NASA Astrophysics Data System (ADS)
Paul, Biswajit; Gopala Krishna, M. R.; Puthiya Veetil, Rishin
2016-07-01
POLIX is a Thomson X-ray polarimeter for a small satellite mission of ISRO. The instrument consists of a collimator, a scatterer and a set proportional counters to detect the scattered X-rays. We will describe the design, specifications, sensitivity, and development status of this instrument and some of the important scientific goals. This instrument will provide unprecedented opportunity to measure X-ray polarisation in the medium energy range in a large number of sources of different classes with a minimum detectable linear polarisation degree of 2-3%. The prime objects for observation with this instrument are the X-ray bright accretion powered neutron stars, accreting black holes in different spectral states, rotation powered pulsars, magnetars, and active galactic nuclei. This instrument will be a bridge between the soft X-ray polarimeters and the Compton polarimeters.
NASA Technical Reports Server (NTRS)
Rodriguez, P. I.
1990-01-01
A linear elastic solution to the problem of minimum weight design of cantilever beams with variable width and depth is presented. The solution shown is for the specific application of the Hubble Space Telescope maintenance mission hardware. During these maintenance missions, delicate instruments must be isolated from the potentially damaging vibration environment of the space shuttle cargo bay during the ascent and descent phases. The leaf springs are designed to maintain the isolation system natural frequency at a level where load transmission to the instruments in a minimum. Nonlinear programming is used for the optimization process. The weight of the beams is the objective function with the deflection and allowable bending stress as the constraint equations. The design variables are the width and depth of the beams at both the free and the fixed ends.
Dhawangale, R M; Kawale, S M; Waghmare, Maya; Pandya, G H; Kondawar, V K
2006-01-01
Environmental laboratories carry out measurement and analysis of a number of physical, chemical and biological parameters. Each parameter requires some sort of instrument for its determination. Providing efficient instrumentation services to various departments of the Institute is an stupendous task. Instrumentation services in the form of installation, operation, repair and maintenanace of electro-mechanical equipment requires an in-depth experience and knowledge of the working, fabrication, design and repair of similar type of instruments so that the need of space, installation pre-requisites, budget constraints, availability of essential spares parts could be assessed. The paper discusses the operation of an environmental instrument repairs and maintenance, and audio-visual facilities. Suggestions for drafting of the proper specifications for procurement of laboratory equipments, such as ovens, furnaces, refrigerators, blowers, audio visual aids, and spares and accessories are given in this paper. The paper also gives the detailed information on various aspects that are needed for checking and testing of the equipment against specification before putting it in operational use. Development of a preventive maintenance program involving QC checks and keeping an inventory of essential spares required are also discussed in this paper. It is felt that such services are essential in providing smooth support to carry out research and development activities of the Institute.
Mobile device-based optical instruments for agriculture
NASA Astrophysics Data System (ADS)
Sumriddetchkajorn, Sarun
2013-05-01
Realizing that a current smart-mobile device such as a cell phone and a tablet can be considered as a pocket-size computer embedded with a built-in digital camera, this paper reviews and demonstrates on how a mobile device can be specifically functioned as a portable optical instrument for agricultural applications. The paper highlights several mobile device-based optical instruments designed for searching small pests, measuring illumination level, analyzing spectrum of light, identifying nitrogen status in the rice field, estimating chlorine in water, and determining ripeness level of the fruit. They are suitable for individual use as well as for small and medium enterprises.
McKay, J; Murphy, D J; Bowie, P; Schmuck, M-L; Lough, M; Eva, K W
2007-04-01
To establish the content validity and specific aspects of reliability for an assessment instrument designed to provide formative feedback to general practitioners (GPs) on the quality of their written analysis of a significant event. Content validity was quantified by application of a content validity index. Reliability testing involved a nested design, with 5 cells, each containing 4 assessors, rating 20 unique significant event analysis (SEA) reports (10 each from experienced GPs and GPs in training) using the assessment instrument. The variance attributable to each identified variable in the study was established by analysis of variance. Generalisability theory was then used to investigate the instrument's ability to discriminate among SEA reports. Content validity was demonstrated with at least 8 of 10 experts endorsing all 10 items of the assessment instrument. The overall G coefficient for the instrument was moderate to good (G>0.70), indicating that the instrument can provide consistent information on the standard achieved by the SEA report. There was moderate inter-rater reliability (G>0.60) when four raters were used to judge the quality of the SEA. This study provides the first steps towards validating an instrument that can provide educational feedback to GPs on their analysis of significant events. The key area identified to improve instrument reliability is variation among peer assessors in their assessment of SEA reports. Further validity and reliability testing should be carried out to provide GPs, their appraisers and contractual bodies with a validated feedback instrument on this aspect of the general practice quality agenda.
Multiloop Integral System Test (MIST): MIST Facility Functional Specification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habib, T F; Koksal, C G; Moskal, T E
1991-04-01
The Multiloop Integral System Test (MIST) is part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox designed plants. MIST is sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral facilities to address the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility --more » the Once Through Integral System (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST Functional Specification documents as-built design features, dimensions, instrumentation, and test approach. It also presents the scaling basis for the facility and serves to define the scope of work for the facility design and construction. 13 refs., 112 figs., 38 tabs.« less
Hubble Space Telescope: Goddard high resolution spectrograph instrument handbook. Version 2.1
NASA Technical Reports Server (NTRS)
Duncan, Douglas K.; Ebbets, Dennis
1990-01-01
The Goddard High Resolution Spectrograph (GHRS) is an ultraviolet spectrometer which has been designed to exploit the imaging and pointing capabilities of the Hubble Space Telescope. It will obtain observations of astronomical sources with greater spectral, spatial and temporal resolution than has been possible with previous space-based instruments. Data from the GHRS will be applicable to many types of scientific investigations, including studies of the interstellar medium, stellar winds, chromospheres and coronae, the byproducts and endproducts of stellar evolution, planetary atmospheres, comets, and many kinds of extragalactic sources. This handbook is intended to introduce the GHRS to potential users. The main purpose is to provide enough information to explore the feasibility of possible research projects and to plan, propose and execute a set of observations. An overview of the instrument performance, which should allow one to evaluate the suitability of the GHRS to specific projects, and a somewhat more detailed description of the GHRS hardware are given. How observing programs will be carried out, the various operating modes of the instrument, and the specific information about the performance of the instrument needed to plan an observation are discussed.
[Measurement of shoulder disability in the athlete: a systematic review].
Fayad, F; Mace, Y; Lefevre-Colau, M M; Poiraudeau, S; Rannou, F; Revel, M
2004-08-01
To identify all available shoulder disability questionnaires and to examine those that could be used for athlete. We systematically reviewed the literature in Medline using the keywords shoulder, function, scale, index, score, questionnaire, disability, quality of life, assessment, and evaluation. We searched for scales used for athletes with the keywords scale name AND (sport OR athlete). Data were completed by using the "Guide des Outils de Mesure et d'Evaluation en Médecine Physique et de Réadaptation" textbook. Analysis took into account the clinimetric quality of the instruments and the number of items specifically related to sports. A total of 37 instruments have been developed to measure disease-, shoulder-specific or upper extremity specific outcome. Older instruments were developed before the advent of modern measurement methods. They usually combined objective and subjective measures. Recent instruments were designed with use of more advanced methods. Most are self-administered questionnaires. Fourteen scales included items assessing sport activity. Four of these scales have been used to assess shoulder disability in athlete. Six scales have been used to assess such disability but do not have specific items related to sports. There is no gold standard for assessing shoulder outcome in the general population and no validated outcome instruments specifically for athletes. We suggest the use of ASES, WOSI and WORC scales for evaluating shoulder function in the recreational athletes. The DASH scale should be evaluated in this population. The principal criterion in evaluating shoulder function in the high level athlete is a return to the same level of sport performance. Further studies are required to identify measurement tools for shoulder disability that have a high predictive value for return to sport.
Andreas, Sylke; Schedler, Kirsten; Schulz, Holger; Nutzinger, Detlev O
2018-02-01
In recent years, a new term-orthorexia nervosa (ON)-has been introduced in the field of clinical assessment and psychotherapy. Orthorexia nervosa is defined as a fixation on healthy food and a pathological obsession to eat food with more natural, higher quality ingredients. Although instruments to measure ON are available, no study on the psychometric properties of the original developed instrument by Bratman (Orthorexia nervosa: Overcoming the obsession with healthful eating, Broadway Books, New York, 2000) in a large clinical sample exists until now. The study was conducted in a large clinic in Germany. The study sample consisted of N = 1122 inpatients, 70% were female, and the mean age was 41 years (SD = 14 years). The main diagnoses at the end of treatment were affective disorders (46%), followed by eating disorders (13%), anxiety disorders (10%), and personality disorders (10%). The patients filled out several instruments, like the Ortho-10, the 10-item version of the orthorexia nervosa instrument, and other construct-related, disorder-specific and construct-distant instruments. The exploratory factor analysis revealed a two-factor structure: an eating disorder-specific factor and an orthorexia-nervosa specific factor. The eating disorder factor showed good convergent and discriminative validity in which patients with eating disorders and those without could correctly be classified. However, the orthorexia-nervosa specific factor revealed no informational gain compared to the eating disorder-specific factor in this clinical sample. Further investigation is necessary to approach the concept of ON and its sense in clinical samples. Level II: evidence obtained from well-designed controlled trials without randomization.
Friend, Tynan H; Paula, Ashley; Klemm, Jason; Rosa, Mark; Levine, Wilton
2018-05-28
Being the economic powerhouses of most large medical centers, operating rooms (ORs) require the highest levels of teamwork, communication, and efficiency in order to optimize patient safety and reduce hospital waste. A major component of OR waste comes from unused surgical instrumentation; instruments that are frequently prepared for procedures but are never touched by the surgical team still require a full reprocessing cycle at the conclusion of the case. Based on our own previous successes in the perioperative domain, in this work we detail an initiative that reduces surgical instrumentation waste of video-assisted thoracoscopic surgery (VATS) procedures by placing thoracotomy conversion instrumentation in a standby location and designing a specific instrument kit to be used solely for VATS cases. Our estimates suggest that this initiative will reduce at least 91,800 pounds of unnecessary surgical instrumentation from cycling through our ORs and reprocessing department annually, resulting in increased OR team communication without sacrificing the highest standard of patient safety.
Reliability and Validity of the Turkish Version of the Job Performance Scale Instrument.
Harmanci Seren, Arzu Kader; Tuna, Rujnan; Eskin Bacaksiz, Feride
2018-02-01
Objective measurement of the job performance of nursing staff using valid and reliable instruments is important in the evaluation of healthcare quality. A current, valid, and reliable instrument that specifically measures the performance of nurses is required for this purpose. The aim of this study was to determine the validity and reliability of the Turkish version of the Job Performance Instrument. This study used a methodological design and a sample of 240 nurses working at different units in four hospitals in Istanbul, Turkey. A descriptive data form, the Job Performance Scale, and the Employee Performance Scale were used to collect data. Data were analyzed using IBM SPSS Statistics Version 21.0 and LISREL Version 8.51. On the basis of the data analysis, the instrument was revised. Some items were deleted, and subscales were combined. The Turkish version of the Job Performance Instrument was determined to be valid and reliable to measure the performance of nurses. The instrument is suitable for evaluating current nursing roles.
History of satellite missions and measurements of the Earth Radiation Budget (1957-1984)
NASA Technical Reports Server (NTRS)
House, F. B.; Gruber, A.; Hunt, G. E.; Mecherikunnel, A. T.
1986-01-01
The history of satellite missions and their measurements of the earth radiation budget from the beginning of the space age until the present time are reviewed. The survey emphasizes the early struggle to develop instrument systems to monitor reflected shortwave and emitted long-wave exitances from the earth, and the problems associated with the interpretation of these observations from space. In some instances, valuable data sets were developed from satellite measurements whose instruments were not specifically designed for earth radiation budget observations.
What is Scanner and NonScanner?
Atmospheric Science Data Center
2014-12-08
... instruments specifically designed by a team of electronic, thermal, and mechanical experts, built and integrated with the ERBS and NOAA ... of three co-planar detectors (longwave, shortwave and total energy), all of which scan from one limb of the Earth to the other, across the ...
VIMOS Instrument Control Software Design: an Object Oriented Approach
NASA Astrophysics Data System (ADS)
Brau-Nogué, Sylvie; Lucuix, Christian
2002-12-01
The Franco-Italian VIMOS instrument is a VIsible imaging Multi-Object Spectrograph with outstanding multiplex capabilities, allowing to take spectra of more than 800 objects simultaneously, or integral field spectroscopy mode in a 54x54 arcsec area. VIMOS is being installed at the Nasmyth focus of the third Unit Telescope of the European Southern Observatory Very Large Telescope (VLT) at Mount Paranal in Chile. This paper will describe the analysis, the design and the implementation of the VIMOS Instrument Control System, using UML notation. Our Control group followed an Object Oriented software process while keeping in mind the ESO VLT standard control concepts. At ESO VLT a complete software library is available. Rather than applying waterfall lifecycle, ICS project used iterative development, a lifecycle consisting of several iterations. Each iteration consisted in : capture and evaluate the requirements, visual modeling for analysis and design, implementation, test, and deployment. Depending of the project phases, iterations focused more or less on specific activity. The result is an object model (the design model), including use-case realizations. An implementation view and a deployment view complement this product. An extract of VIMOS ICS UML model will be presented and some implementation, integration and test issues will be discussed.
Conceptual design of wearpack with physiology detector feature based on wearable instrumentation
NASA Astrophysics Data System (ADS)
Sukirman, Melani; Laksono, Pringgo Widyo; Priadythama, Ilham; Susmartini, Susy; Suhardi, Bambang
2017-11-01
Every company in Indonesia is responsible for their worker health and safety condition as mentioned in UU No I year 1970. In manufacturing industries, there are many manual tasks dealing with high work load and risk, so that they require excellent concentration and physical condition. There is no ideal way to guarantee worker safety without a real time physiological monitoring. This paper reports our ongoing study in conceptual design development of worker's clothing which is equipped with a wearable instrumentation system. The system is designed to detect and measure body temperature and pulse in real time. Some electrical components such as, LCD (liquid crystal display), LEDs (light emitting diode), batteries, and physiological sensors were assembled. All components are controlled by a wearable on board controller. LEDs is used as alert which can indicate abnormal physical conditions. The LCD was added to provide more detail information. TMP 36 and XD-58C were selected as the physiological sensors. Finally, an Arduino Lilypad was chosen for the controller. This instrumentation system was verified by accurately detected and inform physiological condition of 3 subjects. Further we are going to attach the system to a worker's clothing which was specifically designed to simplify and comfortable usage.
NASA Astrophysics Data System (ADS)
Dira-Smolleck, Lori
The purpose of this study was to develop, validate and establish the reliability of an instrument that measures preservice teachers' self-efficacy in regard to the teaching of science as inquiry. The instrument (TSI) is based upon the work of Bandura, Riggs, and Enochs & Riggs (1990). The study used Bandura's theoretical framework in that the instrument uses the self-efficacy construct to explore the beliefs of prospective elementary science teachers with regards to the teaching of science through inquiry: specifically, the two dimensions of self-efficacy beliefs defined by Bandura: personal self-efficacy and outcome expectancy. Self-efficacy in regard to the teaching of science as inquiry was measured through the use of a 69-item Likert scale instrument designed by the author of the study. A 13-step plan was designed and followed in the process of developing the instrument. Using the results from Chronbach Alpha and Analysis of Variance, a 69-item instrument was found to achieve the greatest balance across the construct validity, reliability and item balance with the Essential Elements of Classroom Inquiry content matrix. Based on the standardized development processes used and the associated evidence, the TSI appears to be a content and construct valid instrument, with high internal reliability for use with prospective elementary teachers to assess self-efficacy beliefs in regard to the teaching of science as inquiry. Implications for research, policy and practice are also discussed.
Stage Effects on Stalling and Recovery of a High-Speed 10-Stage Axial- Flow Compressor
1990-06-01
facility C Specific heat of air at constant pressureP Cx Axial velocity DC Direct current DAC Data acquisition computer DCS Design corrected compressor ...was designed to inve3tigate the component performance of an axial -flow compressor while stalling and operating in rotating stall. No attempt was made...Temperatures were measured from a probe configuration similar to the to - pressure design . 68 Table 4.2 Compressor instrumentation RADIAL PROPERTY AXIAL
Measuring spine fracture outcomes: common scales and checklists.
Schoenfeld, Andrew J; Bono, Christopher M
2011-03-01
Although outcome instruments have been used extensively in spine surgical research, few studies at present specifically address their use in investigations regarding spine trauma. In this review we provide a summary of the outcome instruments used most frequently in spine trauma research, identify the unique challenges of studying outcomes of spine trauma patients, and propose an integrated approach that may be beneficial for future studies. We reviewed the use of outcome instruments applicable to spine trauma research, including generic health measures, inventories of back-specific function, pain scales, health related quality of life (HRQOL) instruments, and radiographic determinants of outcome. Several inventories have been utilised to measure clinical outcomes following spinal trauma. Excluding measures of neurological function (e.g. ASIA motor score), none have been specifically validated for use with spine fractures. The SF-36, RMDQ, and ODI are amongst the most commonly used instruments. Importantly, the use of validated functional outcome measures in spine trauma research is hampered by the fact that the pre-morbid state of patients who sustain spine trauma may not be accurately represented by normative values established for the general population. The VAS is used most frequently to assess degree of neck and back pain. Most studies have relied on non-validated measures to determine radiographic results of treatment, although more elegant radiographic metrics exist. Functional outcome measurement of traumatically injured spine patients is challenging because available generic and spine-specific instruments were not designed for or validated in this population. Furthermore, no single inventory is capable of capturing global data necessary to evaluate results following these injuries. Investigations seeking to quantify outcomes following spine trauma should consider the use of a combination of existing surveys in a complementary fashion that should include a generic health survey, a measure of back-specific function, and determinants of bodily pain and work-related disability. Copyright © 2010 Elsevier Ltd. All rights reserved.
Bae, Jin-Hyuk; Yi, Jaeyoung; Kim, Sungtae; Shim, June-Sung; Lee, Keun-Woo
2014-01-01
Cutting efficiency is one of the most important factors to consider when a specific dental diamond rotary instrument is selected. However, the selection of a dental diamond rotary instrument is based on clinical experience rather than any scientific evidence. The purpose of this study was to identify how the cutting efficiency of different types of dental diamond rotary instrument changed with repeated cuts and disinfection. Four types of diamond rotary instrument from 2 dental manufacturers (Shofu, Jin Dental) were investigated with a high-speed air-turbine handpiece. The groups were as follows: S cham group (n=10): chamfer design from Shofu; J cham group (n=10): chamfer design from Jin Dental; S thin group (n=10): thin tapered design from Shofu; J thin group (n=10): thin tapered design from Jin Dental. Changes in the cutting efficiency of diamond rotary instruments on glass ceramic blocks were measured after repeated cuts. Changes in cutting efficiency also were measured for 30 diamond rotary instruments, the same type as those used in group J cham after disinfection with ethylene oxide gas, immersion in solution, or autoclaving. One-way ANOVA, 2-way ANOVA, and repeated-measures ANOVA were used to identify differences in cutting efficiency, in total cutting efficiency, and change trend in cutting efficiency (α=.05). The Tukey honestly significant difference method was used for the post hoc tests. The principal metal components of the diamond rotary instruments were detected with x-ray spectrometry. The mean (standard deviation [SD]) total cutting efficiency after 10 cuts in the 4 groups was in the following order: J cham group (0.210 ± 0.064 g/min) > S cham group (0.170 ± 0.064 g/min) > J thin group (0.130 ± 0.042 g/min) > S thin group (0.010 ± 0.040 g/min) (P<.05).The decrease in the cutting efficiency was greatest after the first cut. The cutting efficiency was not influenced by repeated disinfection. The cutting efficiencies of diamond rotary instruments with different designs and particle sizes showed a decreasing trend after repeated cuts but did not show any change after various disinfecting procedures. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Instrumentation for measuring and recording streamflow data at river-control structures
,
1983-01-01
Instrumentation was developed in the mid to late 60 's to resolve the dilemma of intolerably high percentages of missing streamflow records on certain large and highly controlled streams in industrialized parts of the United States. Analysis of the field situation at specific problem sites quickly suggested that conventional stream gaging techniques should be supplanted by new instruments, designed to measure key hydraulic data at the nearest stream control structures. The key data were found universally to include some combination of a length measurement to specify the vertical height of a gate opening in a dam; measurement of pressure head differential in a turbine; a count of lockages; and precise measurement of time, to give one master reference scale to which all measurements could be keyed. The instruments designed to collect such key data are the shaft position digitizer, the shaft output follower, the STACOM manometer, the lock pressure switch, and the digital data collection console. Although their design was prompted by the need to collect data at river control structures their potential for field use is not that restrictive. Several of these instruments have already found widespread use in the hydrologic data collection program at large. In the 12-1/2 yr period from June 1968 to December 1980 nineteen different river control structures were instrumented. The general experience to date has been a marked improvement in completeness of record, with the average performance somewhere in the 80 percentile range. Performance percentiles at individual sites have ranged from the mid 90 's to about 70. Maintenance records show the instruments to be virtually trouble free, except for the unpredictable acts of nature and man. (Author 's abstract)
Measuring the Optical Properties of Astrophysical Dust Analogues: Instrumentation and Methods
NASA Technical Reports Server (NTRS)
Rinehart, S. A.; Benford, D. J.; Cataldo, G.; Dwek, E.; Henry, R.; Kinzer, R. E., Jr.; Nuth, J.; Silverberg, R.; Wheeler, C.; Wollack, E.
2011-01-01
Dust is found throughout the universe and plays an important role for a wide range of astrophysical phenomena. In recent years, new infrared facilities have provided powerful new data for understanding these phenomena. However, interpretation of these data is often complicated by a lack of complementary information about the optical properties of astronomically relevant materials. The Optical Properties of Astronomical Silicates with Infrared Techniques (OPASI-T) program at NASA's Goddard Space Flight Center is designed to provide new high-quality laboratory data from which we can derive the optical properties of astrophysical dust analogues. This program makes use of multiple instruments, including new equipment designed and built specifically for this purpose. The suite of instruments allows us to derive optical properties over a wide wavelength range, from the near-infrared through the millimeter, also providing the capability for exploring how these properties depend upon the temperature of the sample. In this paper, we discuss the overall structure of the research program, describe the new instruments that have been developed to meet the science goals, and demonstrate the efficacy of these tools.
NASA Technical Reports Server (NTRS)
Schott, John; Gerace, Aaron; Brown, Scott; Gartley, Michael; Montanaro, Matthew; Reuter, Dennis C.
2012-01-01
The next Landsat satellite, which is scheduled for launch in early 2013, will carry two instruments: the Operational Land Imager (OLI) and the Thermal Infrared Sensor (TIRS). Significant design changes over previous Landsat instruments have been made to these sensors to potentially enhance the quality of Landsat image data. TIRS, which is the focus of this study, is a dual-band instrument that uses a push-broom style architecture to collect data. To help understand the impact of design trades during instrument build, an effort was initiated to model TIRS imagery. The Digital Imaging and Remote Sensing Image Generation (DIRSIG) tool was used to produce synthetic "on-orbit" TIRS data with detailed radiometric, geometric, and digital image characteristics. This work presents several studies that used DIRSIG simulated TIRS data to test the impact of engineering performance data on image quality in an effort to determine if the image data meet specifications or, in the event that they do not, to determine if the resulting image data are still acceptable.
Training evaluation final report
NASA Technical Reports Server (NTRS)
Sepulveda, Jose A.
1992-01-01
In the area of management training, 'evaluation' refers both to the specific evaluation instrument used to determine whether a training effort was considered effective, and to the procedures followed to evaluate specific training requests. This report recommends to evaluate new training requests in the same way new procurement or new projects are evaluated. This includes examining training requests from the perspective of KSC goals and objectives, and determining expected ROI of proposed training program (does training result in improved productivity, through savings of time, improved outputs, and/or personnel reduction?). To determine whether a specific training course is effective, a statement of what constitutes 'good performance' is required. The user (NOT the Training Branch) must define what is 'required level of performance'. This 'model' will be the basis for the design and development of an objective, performance-based, training evaluation instrument.
Ocean Bottom Seismograph Performance during the Cascadia Initiative
NASA Astrophysics Data System (ADS)
Aderhold, K.; Evers, B.
2015-12-01
The Ocean Bottom Seismograph Instrument Pool (OBSIP) provides instrumentation and operations support for the Cascadia Initiative community experiment. This experiment investigates geophysical processes across the Cascadia subduction zone through a combination of onshore and offshore seismic data. The recovery of Year 4 instruments in September 2015 marks the conclusion of a multi-year experiment that utilized 60 ocean-bottom seismographs (OBSs) specifically designed for the subduction zone boundary, including shallow/deep water deployments and active fisheries. The new instruments feature trawl-resistant enclosures designed by Lamont-Doherty Earth Observatory (LDEO) and Scripps Institution of Oceanography (SIO) for shallow deployment [water depth ≤ 500 m], as well as new deep-water instruments designed by Woods Hole Oceanographic Institute (WHOI). Existing OBSIP instruments were also deployed along the Blanco Transform Fault and on the Gorda Plate through complementary experiments. Stations include differential pressure gauges (DPG) and absolute pressure gauges (APG). All data collected from the Cascadia, Blanco, and Gorda deployments will be freely available through the Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC). The Cascadia Initiative is the largest amphibious seismic experiment undertaken to date and demonstrates an effective structure for community experiments through collaborative efforts from the Cascadia Initiative Expedition Team (CIET), OBSIP (institutional instrument contributors [LDEO, SIO, WHOI] and Management Office [IRIS]), and the IRIS DMC. The successes and lessons from Cascadia are a vital resource for the development of a Subduction Zone Observatory (SZO). To guide future efforts, we investigate the quality of the Cascadia OBS data using basic metrics such as instrument recovery and more advanced metrics such as noise characteristics through power spectral density analysis. We also use this broad and diverse deployment to determine how water depth and instrument shielding influence recorded data. Additionally, multi-year data collection allows us to identify temporal noise trends so that we can take advantage of quieter seasons for future deployments.
Miernik, Arkadiusz; Schoenthaler, Martin; Lilienthal, Kerstin; Frankenschmidt, Alexander; Karcz, Wojciech Konrad; Kuesters, Simon
2012-07-01
Different types of single-incision laparoscopic surgery (SILS) have become increasingly popular. Although SILS is technically even more challenging than conventional laparoscopy, published data of first clinical series seem to demonstrate the feasibility of these approaches. Various attempts have been made to overcome restrictions due to loss of triangulation in SILS by specially designed SILS-specific instruments. This study involving novices in a dry lab compared task performances between conventional laparoscopic surgery (CLS) and single-port laparoscopic surgery (SPLS) using newly designed pre-bent instruments. In this study, 90 medical students without previous experience in laparoscopic techniques were randomly assigned to undergo one of three procedures: CLS, SPLS using two pre-bent instruments (SPLS-pp), or SPLS using one pre-bent and one straight laparoscopic instrument (SPLS-ps). In the dry lab, the participants performed four typical laparoscopic tasks of increasing difficulty. Evaluation included performance times or number of completed tasks within a given time frame. All performances were videotaped and evaluated for unsuccessful attempts and unwanted interactions of instruments. Using subjective questionnaires, the participants rated difficulties with two-dimensional vision and coordination of instruments. Task performances were significantly better in the CLS group than in either SPLS group. The SPLS-ps group showed a tendency toward better performances than the SPLS-pp group, but the difference was not significant. Video sequences and participants` questionnaires showed instrument interaction as the major problem in the single-incision surgery groups. Although SILS is feasible, as shown in clinical series published by laparoscopically experienced experts, SILS techniques are demanding due to restrictions that come with the loss of triangulation. These can be compensated only partially by currently available SILS-designed instruments. The future of SILS depends on further improvements in the available equipment or the development of new approaches such as needlescopically assisted or robotically assisted procedures.
NASA Astrophysics Data System (ADS)
King, Bruce H.; Ellis, Thomas; Old, Tom E.
2009-05-01
A fast-scanning, high-resolution FTIR spectroradiometer has been designed and built for use in remote sensing, stand-off detection, and spectral-temporal characterization of fast, energetic infrared events. The instrument design uses a Michelson-type interferometer with a rotary modulator which is capable of continuous measurement of infrared spectra at a rate of 1000 scans per second with 4 cm-1 resolution in the 2 - 25 micron spectral range. Sensitivity, spectral accuracy, and radiometric precision are discussed along with specific design parameters. This instrument can be used for passive sensing as a stand-alone sensor, or for active sensing as a receiver when used in conjunction with a highenergy excitation source such as a laser. Applications include muzzle flash signature measurement, ordnance detonation characterization, missile plume identification, and rocket motor combustion diagnostics.
Instrument for Analysis of Organic Compounds on Other Planets
NASA Technical Reports Server (NTRS)
Daulton, Riley M.; Hintze, Paul E.
2016-01-01
The goal of this project is to develop the Instrument for Solvent Extraction and Analysis of Extraterrestrial Bodies using In Situ Resources (ISEE). Specifically, ISEE will extract and characterize organic compounds from regolith which is found on the surface of other planets or asteroids. The techniques this instrument will use are supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC). ISEE aligns with NASA's goal to expand the frontiers of knowledge, capability, and opportunities in space in addition to supporting NASA's aim to search for life elsewhere by characterizing organic compounds. The outcome of this project will be conceptual designs of 2 components of the ISEE instrument as well as the completion of proof-of-concept extraction experiments to demonstrate the capabilities of SFE. The first conceptual design is a pressure vessel to be used for the extraction of the organic compounds from the regolith. This includes a comparison of different materials, geometry's, and a proposition of how to insert the regolith into the vessel. The second conceptual design identifies commercially available fluid pumps based on the requirements needed to generate supercritical CO2. The proof-of-concept extraction results show the percent mass lost during standard solvent extractions of regolith with organic compounds. This data will be compared to SFE results to demonstrate the capabilities of ISEE's approach.
Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST/AFTA
NASA Technical Reports Server (NTRS)
Gong, Qian; Mcelwain, Michael; Greeley, Bradford; Grammer, Bryan; Marx, Catherine; Memarsadeghi, Nargess; Stapelfeldt, Karl; Hilton, George; Sayson, Jorge Llop; Perrin, Marshall;
2015-01-01
Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey Telescope/Astrophysics Focused Telescope Assets (WFIRST/AFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC) cofigurations. We discuss why the lenslet array based IFS is selected for PISCES. We present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the specific function of our pinhole mask on the back surface of the lenslet array to further suppress star light introduced speckles. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.
Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST-AFTA
NASA Technical Reports Server (NTRS)
Gong, Qian; Mcelwain, Michael; Greeley, Bradford; Grammer, Bryan; Marx, Catherine; Memarsadeghi, Nargess; Stapelfeldt, Karl; Hilton, George; Sayson, Jorge Llop; Perrin, Marshall;
2015-01-01
Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey Telescope/Astrophysics Focused Telescope Assets (WFIRST-AFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory (JPL) and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC) configurations. We discuss why the lenslet array based IFS was selected for PISCES. We present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the specific function of our pinhole mask on the back surface of the lenslet array to reduce the diffraction from the edge of the lenslets. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.
Bagraith, Karl; Chardon, Lydia; King, Robert John
2010-11-01
Although there are widely accepted and utilized models and frameworks for nondirective counseling (NDC), there is little in the way of tools or instruments designed to assist in determining whether or not a specific episode of counseling is consistent with the stated model or framework. The Counseling Progress and Depth Rating Instrument (CPDRI) was developed to evaluate counselor integrity in the use of Egan's skilled helper model in online counseling. The instrument was found to have sound internal consistency, good interrater reliability, and good face and convergent validity. The CPDRI is, therefore, proposed as a useful tool to facilitate investigation of the degree to which counselors adhere to and apply a widely used approach to NDC.
Science Instrument Sensitivities to Radioisotope Power System Environment
NASA Technical Reports Server (NTRS)
Bairstow, Brian; Lee, Young; Smythe, William; Zakrajsek, June
2016-01-01
Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight system could be mitigated with shading and pointing if required by the mission. Alternatively, excess heat could prove beneficial in providing needed heat to spacecraft components and instruments in some thermal environments. Vibration for a new higher-power Stirling Radioisotope Generator (SRG) would be expected to be similar to the recent Advanced Stirling Radioisotope Generator (ASRG) design. While vibration should be low, it must be considered and addressed during spacecraft and instrument design. EMI and magnetic fields for new RPS concepts are expected to be low as for the current RPS, but must be considered and addressed if the mission includes sensitive instruments such as magnetometers. The assessment conducted for this paper focused on orbiter instrument payloads for two representative mission concepts- a Titan Saturn System Mission (TSSM) and a Uranus Orbiter and Probe (UOP)-since both of these Decadal Survey concepts would include many diverse instruments on board. Quick-look design studies using notional new RPS concepts were carried out for these two mission concepts, and their specific instrument packages were analyzed for their interactions with new RPS designs. The original Decadal Survey TSSM and UOP concepts did not have complete instrument performance requirements so typical measurement requirements were used where needed. Then, the general RPS environments were evaluated for impacts to various types of instruments. This paper describes how the potential impacts of the RPS on science instruments and measurements were assessed, which impacts were addressed, proposed mitigation strategies against those impacts, and provides an overview of future work.
CAFE: Calar Alto Fiber-fed Échelle spectrograph
NASA Astrophysics Data System (ADS)
Aceituno, J.; Sánchez, S. F.; Grupp, F.; Lillo, J.; Hernán-Obispo, M.; Benitez, D.; Montoya, L. M.; Thiele, U.; Pedraz, S.; Barrado, D.; Dreizler, S.; Bean, J.
2013-04-01
We present here CAFE, the Calar Alto Fiber-fed Échelle spectrograph, a new instrument built at the Centro Astronomico Hispano Alemán (CAHA). CAFE is a single-fiber, high-resolution (R ~ 70 000) spectrograph, covering the wavelength range between 3650-9800 Å. It was built on the basis of the common design for Échelle spectrographs. Its main aim is to measure radial velocities of stellar objects up to V ~ 13-14 mag with a precision as good as a few tens of m s-1. To achieve this goal the design was simplified at maximum, removing all possible movable components, the central wavelength is fixed, as is the wavelength coverage; there is no filter wheel, etc. Particular care was taken with the thermal and mechanical stability. The instrument is fully operational and publically accessible at the 2.2 m telescope of the Calar Alto Observatory. In this article we describe (i) the design, summarizing its manufacturing phase; (ii) characterize the main properties of the instrument; (iii) describe the reduction pipeline; and (iv) show the results from the first light and commissioning runs. The preliminar results indicate that the instrument fulfills the specifications and can achieve the planned goals. In particular, the results show that the instrument is more efficient than anticipated, reaching a signal-to-noise of ~20 for a stellar object as faint as V ~ 14.5 mag in ~2700 s integration time. The instrument is a wonderful machine for exoplanetary research (by studying large samples of possible systems cotaining massive planets), galactic dynamics (highly precise radial velocities in moving groups or stellar associations), or astrochemistry.
Thermal Infrared Spectral Imager for Airborne Science Applications
NASA Technical Reports Server (NTRS)
Johnson, William R.; Hook, Simon J.; Mouroulis, Pantazis; Wilson, Daniel W.; Gunapala, Sarath D.; Hill, Cory J.; Mumolo, Jason M.; Eng, Bjorn T.
2009-01-01
An airborne thermal hyperspectral imager is under development which utilizes the compact Dyson optical configuration and quantum well infrared photo detector (QWIP) focal plane array. The Dyson configuration uses a single monolithic prism-like grating design which allows for a high throughput instrument (F/1.6) with minimal ghosting, stray-light and large swath width. The configuration has the potential to be the optimal imaging spectroscopy solution for lighter-than-air (LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The planned instrument specifications are discussed as well as design trade-offs. Calibration testing results (noise equivalent temperature difference, spectral linearity and spectral bandwidth) and laboratory emissivity plots from samples are shown using an operational testbed unit which has similar specifications as the final airborne system. Field testing of the testbed unit was performed to acquire plots of apparent emissivity for various known standard minerals (such as quartz). A comparison is made using data from the ASTER spectral library.
Geytenbeek, Joke J; Mokkink, Lidwine B; Knol, Dirk L; Vermeulen, R Jeroen; Oostrom, Kim J
2014-09-01
In clinical practice, a variety of diagnostic tests are available to assess a child's comprehension of spoken language. However, none of these tests have been designed specifically for use with children who have severe motor impairments and who experience severe difficulty when using speech to communicate. This article describes the process of investigating the reliability and validity of the Computer-Based Instrument for Low Motor Language Testing (C-BiLLT), which was specifically developed to assess spoken Dutch language comprehension in children with cerebral palsy and complex communication needs. The study included 806 children with typical development, and 87 nonspeaking children with cerebral palsy and complex communication needs, and was designed to provide information on the psychometric qualities of the C-BiLLT. The potential utility of the C-BiLLT as a measure of spoken Dutch language comprehension abilities for children with cerebral palsy and complex communication needs is discussed.
Karimi, H; Dolatshahee, B; Momeni, K; Khodabakhshi, A; Rezaei, M; Kamrani, A A
2010-09-01
Reminiscence therapy is a psychological intervention which is specifically designed to address issues of particular relevance to older adults, such as depression. The latest approach to the research on therapeutic utility of reminiscence is gaining popularity among researchers and practitioners, and has yielded promising results. Specifying different types of reminiscence is a crucial component of the approach. The aim of this study was to examine the therapeutic effectiveness of integrative and instrumental types of reminiscence for the treatment of depression in institutionalized older adults dwelling in a nursing home. The study employed a three-group pre-post-test design with random allocation to instrumental or integrative reminiscence or an active social discussion control condition. Twenty-nine institutionalized older adults (12 men and 17 women) with depressive symptoms varying from mild to severe constituted the sample. The interventions were implemented in a short-form group format. Analysis of changes from pre-test to post-test revealed that integrative reminiscence therapy led to statistically significant reduction in symptoms of depression in contrast with the control group. Although instrumental reminiscence therapy also reduced depressive symptoms, this improvement was not statistically significant compared to the control group. This study provides additional support for the effectiveness of integrative reminiscence therapy as an intervention for depressed older adults living in residential care settings. This study also provides support for the hypothesis that certain types of reminiscence produce their own specific effects.
The Lightcurve Legacy of COS and STIS
NASA Astrophysics Data System (ADS)
Ely, Justin; Bourque, Matthew; Debes, John; Kriss, Gerard; McCullough, Peter R.
2015-08-01
The Cosmic Origin Spectrograph (COS) and Space Telescope Imaging Spectrograph (STIS) onboard the Hubble Space Telescope (HST) have been advancing astronomy with high quality spectroscopic products for years, and in the case of STIS, more than a decade. Though already incredibly productive, there remains an untapped potential of discovery in the data of these instruments. Due to their specific detector designs, both of these instruments can operate in a TIME-TAG mode where each individual photon's arrival time is recorded. Though this ability is typically utilized to provide second-by-second calibrations to the final spectral data, this mode can also be exploited to re-examine the data in the time domain, turning spectra into lightcurves with high temporal and spectral resolution.Nearly all COS and many STIS observations are taken in TIME-TAG mode. For observations that were not specifically designed to carry out time-resolved spectroscopy, the archived data represent an untapped space for discovery. We present here the current status of our on-going efforts to produce a collection of high-level science lightcurves for the entire COS and STIS TIME-TAG archives. Included are details of the time-series reduction software, instrument capabilities in the time-domain, and demonstrations of the current reduced products for a wide range of variable targets such as transits, stellar flares, and white dwarf pulsations.
NASA Astrophysics Data System (ADS)
Senesi, R.; Andreani, C.; Bowden, Z.; Colognesi, D.; Degiorgi, E.; Fielding, A. L.; Mayers, J.; Nardone, M.; Norris, J.; Praitano, M.; Rhodes, N. J.; Stirling, W. G.; Tomkinson, J.; Uden, C.
2000-03-01
The VESUVIO project aims to provide unique prototype instrumentation at the ISIS-pulsed neutron source and to establish a routine experimental and theoretical program in neutron scattering spectroscopy at eV energies. This instrumentation will be specifically designed for high momentum, (20 Å-11 eV) inelastic neutron scattering studies of microscopic dynamical processes in materials and will represent a unique facility for EU researchers. It will allow to derive single-particle kinetic energies and single-particle momentum distributions, n(p), providing additional and/or complementary information to other neutron inelastic spectroscopic techniques.
Prototyping Instruments for Chemical Laboratory Using Inexpensive Electronic Modules.
Urban, Pawel L
2018-05-15
Open-source electronics and programming can augment chemical and biomedical research. Currently, chemists can choose from a broad range of low-cost universal electronic modules (microcontroller boards and single-board computers) and use them to assemble working prototypes of scientific tools to address specific experimental problems and to support daily research work. The learning time can be as short as a few hours, and the required budget is often as low as 50 USD. Prototyping instruments using low-cost electronic modules gives chemists enormous flexibility to design and construct customized instrumentation, which can reduce the delays caused by limited access to high-end commercial platforms. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Patterson, Emma; Quetel, Anna-Karin; Lilja, Karin; Simma, Marit; Olsson, Linnea; Elinder, Liselotte Schäfer
2013-06-01
To develop a feasible, valid, reliable web-based instrument to objectively evaluate school meal quality in Swedish primary schools. The construct 'school meal quality' was operationalized by an expert panel into six domains, one of which was nutritional quality. An instrument was drafted and pilot-tested. Face validity was evaluated by the panel. Feasibility was established via a large national study. Food-based criteria to predict the nutritional adequacy of school meals in terms of fat quality, iron, vitamin D and fibre content were developed. Predictive validity was evaluated by comparing the nutritional adequacy of school menus based on these criteria with the results from a nutritional analysis. Inter-rater reliability was also assessed. The instrument was developed between 2010 and 2012. It is designed for use in all primary schools by school catering and/or management representatives. A pilot-test of eighty schools in Stockholm (autumn 2010) and a further test of feasibility in 191 schools nationally (spring 2011). The four nutrient-specific food-based criteria predicted nutritional adequacy with sensitivity ranging from 0.85 to 1.0, specificity from 0.45 to 1.0 and accuracy from 0.67 to 1.0. The sample in the national study was statistically representative and the majority of users rated the questionnaire positively, suggesting the instrument is feasible. The inter-rater reliability was fair to almost perfect for continuous variables and agreement was ≥ 67 % for categorical variables. An innovative web-based system to comprehensively monitor school meal quality across several domains, with validated questions in the nutritional domain, is available in Sweden for the first time.
Report of the Power Sub systems Panel. [spacecraft instrumentation technology
NASA Technical Reports Server (NTRS)
1979-01-01
Problems in spacecraft power system design, testing, integration, and operation are identified and solutions are defined. The specific technology development problems discussed include substorm and plasma design data, modeling of the power subsystem and components, power system monitoring and degraded system management, rotary joints for transmission of power and signals, nickel cadmium battery manufacturing and application, on-array power management, high voltage technology, and solar arrays.
NASA Technical Reports Server (NTRS)
Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc
2014-01-01
In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a Qualification Model. The selected linear Slit Change Mechanism design concept, consisting of a flexible guiding system driven by a hermetically sealed linear drive mechanism, is considered validated for the specific application of the SPICE instrument, with great potential for other special applications where contamination and high precision positioning are dominant design drivers.
Nuclear Technology Series. Course 16: Mechanical Component Characteristics and Specifications.
ERIC Educational Resources Information Center
Center for Occupational Research and Development, Inc., Waco, TX.
This technical specialty course is one of thirty-five courses designed for use by two-year postsecondary institutions in five nuclear technician curriculum areas: (1) radiation protection technician, (2) nuclear instrumentation and control technician, (3) nuclear materials processing technician, (4) nuclear quality-assurance/quality-control…
Stress Be Not Proud: The Myth of Burnout.
ERIC Educational Resources Information Center
DeMoulin, Donald F.
1991-01-01
Analysis of data from 827 professional educators, using the Career Awareness Index and the Instrument Summary Assessment Program, indicates that "burnout" may be an inappropriate descriptor of low to moderate levels of self-efficacy and personal productivity. Professional development activities should be specifically designed to match individual…
Live load monitoring for the I-10 twin span bridge : research project capsule.
DOT National Transportation Integrated Search
2014-10-01
To establish a site-specific database for bridge evaluation and future bridge design, : DOTD established a long-term health monitoring system at the I-10 Twin Span Bridge. : The bridge is instrumented from deck to piles to capture bridge response (bo...
NASA Technical Reports Server (NTRS)
Teper, G. L.; Hon, R. H.; Smyth, R. K.
1977-01-01
Specifications which define the system functional requirements, the subsystem and interface needs, and other requirements such as maintainability, modularity, and reliability are summarized. A design definition of all required avionics functions and a system risk analysis are presented.
NASA Astrophysics Data System (ADS)
Schultz, A.; Urquhart, S.; Slater, M.
2010-12-01
At present, the US academic community has access to two national electromagnetic (EM) instrument pools that support long-period magnetotelluric (MT) equipment suitable for crust-mantle scale studies. The requirements of near surface geophysics, hydrology, glaciology, as well as the full range of crust and mantle investigations require development of new capabilities in data acquisition with broader frequency bandwidth than these existing units, increased instrument numbers, and concomitant developments in 3D/4D data interpretation. NSF Major Research Instrumentation support has been obtained to meet these requirements by developing an initial set of next-generation instruments as a National Geoelectromagnetic Facility (NGF), available to all PIs on a cost recovery basis, and operated by Oregon State University (OSU). In contrast to existing instruments with data acquisition systems specialized to operate within specific frequency bands and for specific electromagnetic methods, the NGF model "Zen/5" instruments being co-developed by OSU and Zonge Research and Engineering Organization are based on modular receivers with a flexible number of digital and analog input channels, designed to acquire EM data at dc, and from frequencies ranging from micro-Hz to MHz. These systems can be deployed in a compact, low power configuration for extended deployments (e.g. for crust-mantle scale experiments), or in a high frequency sampling mode for near surface work. The NGF is also acquiring controlled source EM transmitters, so that investigators may carry out magnetotelluric, audio-MT, radiofrequency-MT, as well as time-domain/transient EM and DC resistivity studies. The instruments are designed to simultaneously accommodate multiple electric field dipole sensors, magnetic fluxgates and induction coil sensors. Sample rates as high as 2.5 MHz with resolution between 24 and 32 bits, depending on sample rate, are specified to allow for high fidelity recording of waveforms. The NGF is accepting instrument use requests from investigators planning electromagnetic surveys via webform submission on its web site ngf.coas.oregonstate.edu. The site is also a port of entry to request access to the 46 long period magnetotelluric instruments also operated by OSU as national instrument pools. Cyberinfrastructure support is available to investigators, including field computers, EM data processing software, and access to a hybrid CPU-GPU parallel computing environment, currently configured with dual Intel Westmere hexacore CPUs and 960 NVidia Tesla and 1792 Nvidia Fermi GPU cores. The capabilities of the Zen/5 receivers will be presented, with examples of data acquired from a recent shallow water marine controlled source experiment conducted in coastal Oregon as part of an effort to locate a buried submarine pipeline, using a 1.1 KW 256 Hz signal source imposed on the pipeline from shore. A Zen/5 prototype instrument, modified for marine use through support by the Oregon Wave Energy Trust, demonstrated the marine capabilities of the NGF instrument design.
ICESat-2 simulated data from airborne altimetery
NASA Astrophysics Data System (ADS)
Brunt, K. M.; Neumann, T.; Markus, T.; Brenner, A. C.; Barbieri, K.; Field, C.; Sirota, M.
2010-12-01
Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) is scheduled to launch in 2015 and will carry onboard the Advanced Topographic Laser Altimeter System (ATLAS), which represents a new approach to spaceborne determination of surface elevations. Specifically, the current ATLAS design is for a micropulse, multibeam, photon-counting laser altimeter with lower energy, a shorter pulse width, and a higher repetition rate relative to the Geoscience Laser Altimeter (GLAS), the instrument that was onboard ICESat. Given the new and untested technology associated with ATLAS, airborne altimetry data is necessary (1) to test the proposed ATLAS instrument geometry, (2) to validate instrument models, and (3) to assess the atmospheric effects on multibeam altimeters. We present an overview of the airborne instruments and datasets intended to address the ATLAS instrument concept, including data collected over Greenland (July 2009) using an airborne SBIR prototype 100 channel, photon-counting, terrain mapping altimeter, which addresses the first of these 3 scientific concerns. Additionally, we present the plan for further simulator data collection over vegetated and ice covered regions using Multiple Altimeter Beam Experimental Lidar (MABEL), intended to address the latter two scientific concerns. As the ICESAT-2 project is in the design phase, the particular configuration of the ATLAS instrument may change. However, we expect this work to be relevant as long as ATLAS pursues a photon-counting approach.
Manufacturability: from design to SPC limits through "corner-lot" characterization
NASA Astrophysics Data System (ADS)
Hogan, Timothy J.; Baker, James C.; Wesneski, Lisa; Black, Robert S.; Rothenbury, Dave
2004-12-01
Texas Instruments" Digital Micro-mirror Device, is used in a wide variety of optical display applications ranging from fixed and portable projectors to high-definition television (HDTV) to digital cinema projection systems. A new DMD pixel architecture, called "FTP", was designed and qualified by Texas Instruments DLPTMTM Group in 2003 to meet increased performance objectives for brightness and contrast ratio. Coordination between design, test and fabrication groups was required to balance pixel performance requirements and manufacturing capability. "Corner Lot" designed experiments (DOE) were used to verify "fabrication space" available for the pixel design. The corner lot technique allows confirmation of manufacturability projections early in the design/qualification cycle. Through careful design and analysis of the corner-lot DOE, a balance of critical dimension (cd) "budgets" is possible so that specification and process control limits can be established that meet both customer and factory requirements. The application of corner-lot DOE is illustrated in a case history of the DMD "FTP" pixel. The process for balancing test parameter requirements with multiple critical dimension budgets is shown. MEMS/MOEMS device design and fabrication can use similar techniques to achieve agressive design-to-qualification goals.
Manufacturability: from design to SPC limits through "corner-lot" characterization
NASA Astrophysics Data System (ADS)
Hogan, Timothy J.; Baker, James C.; Wesneski, Lisa; Black, Robert S.; Rothenbury, Dave
2005-01-01
Texas Instruments" Digital Micro-mirror Device, is used in a wide variety of optical display applications ranging from fixed and portable projectors to high-definition television (HDTV) to digital cinema projection systems. A new DMD pixel architecture, called "FTP", was designed and qualified by Texas Instruments DLPTMTM Group in 2003 to meet increased performance objectives for brightness and contrast ratio. Coordination between design, test and fabrication groups was required to balance pixel performance requirements and manufacturing capability. "Corner Lot" designed experiments (DOE) were used to verify "fabrication space" available for the pixel design. The corner lot technique allows confirmation of manufacturability projections early in the design/qualification cycle. Through careful design and analysis of the corner-lot DOE, a balance of critical dimension (cd) "budgets" is possible so that specification and process control limits can be established that meet both customer and factory requirements. The application of corner-lot DOE is illustrated in a case history of the DMD "FTP" pixel. The process for balancing test parameter requirements with multiple critical dimension budgets is shown. MEMS/MOEMS device design and fabrication can use similar techniques to achieve agressive design-to-qualification goals.
History and current status of mini-invasive thoracic surgery
He, Jianxing
2011-01-01
Mini-invasive thoracic technique mainly refers to a technique involving the significant reduction of the chest wall access-related trauma. Notably, thoracoscope is the chief representative. The development of thoracoscope technique is characterized by: developing from direct peep to artificial lighting, then combination with image and video technique in equipments; technically developing from diagnostic to therapeutic approaches; developing from simpleness to complexity in application scope; and usually developing together with other techniques. At present, the widely used mini-invasive thoracic surgery refers to the mini-open thoracic surgery performed mainly by using some instruments to control target tissues and organs based on the vision associated with multi-limb coordination, which may be hand-assisted if necessary. The mini-invasive thoracic surgery consists of three approaches including video-assisted thoracic surgery (VATS), video-assisted Hybrid and hand-assisted VATS. So far the mini-invasive thoracic technique has achieved great advances due to the development in instruments of mini-invasive thoracic surgery which has the following features: instruments of mini-invasive thoracic surgery appear to be safe and practical, and have successive improvement and diversification in function; the specific instruments of open surgeries has been successively developed into dedicated instruments of endoscopic surgery; the application of endoscopic mechanical suture device generates faster fragmentation and reconstruction of organ tissues; the specific delicated instruments of endoscopic surgery have rapid development and application; and the simple instruments structurally similar to the conventional instruments are designed according to the mini-incison. In addition, the mini-invasive thoracic technique is widely used in five aspects including diseases of pleura membrane and chest wall, lung diseases, esophageal diseases, mediastinal diseases and heart diseases. However, there remain many problems in specifications and trainings, economic cost, conservation and innovation. Therefore, particular attention should be paid to these problems. Nevertheless, the promotion of thoracic surgery appears promising in the future. PMID:22263074
Experimental Flow Models for SSME Flowfield Characterization
NASA Technical Reports Server (NTRS)
Abel, L. C.; Ramsey, P. E.
1989-01-01
Full scale flow models with extensive instrumentation were designed and manufactured to provide data necessary for flow field characterization in rocket engines of the Space Shuttle Main Engine (SSME) type. These models include accurate flow path geometries from the pre-burner outlet through the throat of the main combustion chamber. The turbines are simulated with static models designed to provide the correct pressure drop and swirl for specific power levels. The correct turbopump-hot gas manifold interfaces were designed into the flow models to permit parametric/integration studies for new turbine designs. These experimental flow models provide a vehicle for understanding the fluid dynamics associated with specific engine issues and also fill the more general need for establishing a more detailed fluid dynamic base to support development and verification of advanced math models.
MOEMs devices for future astronomical instrumentation in space
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Liotard, Arnaud; Lanzoni, Patrick; ElHadi, Kacem; Waldis, Severin; Noell, Wilfried; de Rooij, Nico; Conedera, Veronique; Fabre, Norbert; Muratet, Sylvaine; Camon, Henri
2017-11-01
Based on the micro-electronics fabrication process, Micro-Opto-Electro-Mechanical Systems (MOEMS) are under study in order to be integrated in next-generation astronomical instruments for ground-based and space telescopes. Their main advantages are their compactness, scalability, specific task customization using elementary building blocks, and remote control. At Laboratoire d'Astrophysique de Marseille, we are engaged since several years in the design, realization and characterization of programmable slit masks for multi-object spectroscopy and micro-deformable mirrors for wavefront correction. First prototypes have been developed and show results matching with the requirements.
TAUKAM: a new prime-focus camera for the Tautenburg Schmidt Telescope
NASA Astrophysics Data System (ADS)
Stecklum, Bringfried; Eislöffel, Jochen; Klose, Sylvio; Laux, Uwe; Löwinger, Tom; Meusinger, Helmut; Pluto, Michael; Winkler, Johannes; Dionies, Frank
2016-08-01
TAUKAM stands for "TAUtenburg KAMera", which will become the new prime-focus imager for the Tautenburg Schmidt telescope. It employs an e2v 6kx6k CCD and is under manufacture by Spectral Instruments Inc. We describe the design of the instrument and the auxiliary components, its specifications as well as the concept for integrating the device into the telescope infrastructure. First light is foreseen in 2017. TAUKAM will boost the observational capabilities of the telescope for what concerns optical wide-field surveys.
Modular Integrated Stackable Layers (MISL) 1.1 Design Specification. Design Guideline Document
NASA Technical Reports Server (NTRS)
Yim, Hester J.
2012-01-01
This document establishes the design guideline of the Modular Instrumentation Data Acquisition (MI-DAQ) system in utilization of several designs available in EV. The MI- DAQ provides the options to the customers depending on their system requirements i.e. a 28V interface power supply, a low power battery operated system, a low power microcontroller, a higher performance microcontroller, a USB interface, a Ethernet interface, a wireless communication, various sensor interfaces, etc. Depending on customer's requirements, the each functional board can be stacked up from a bottom level of power supply to a higher level of stack to provide user interfaces. The stack up of boards are accomplished by a predefined and standardized power bus and data bus connections which are included in this document along with other physical and electrical guidelines. This guideline also provides information for a new design options. This specification is the product of a collaboration between NASA/JSC/EV and Texas A&M University. The goal of the collaboration is to open source the specification and allow outside entities to design, build, and market modules that are compatible with the specification. NASA has designed and is using numerous modules that are compatible to this specification. A limited number of these modules will also be released as open source designs to support the collaboration. The released designs are listed in the Applicable Documents.
Hydrogen Epoch of Reionization Array (HERA)
NASA Astrophysics Data System (ADS)
DeBoer, David R.; Parsons, Aaron R.; Aguirre, James E.; Alexander, Paul; Ali, Zaki S.; Beardsley, Adam P.; Bernardi, Gianni; Bowman, Judd D.; Bradley, Richard F.; Carilli, Chris L.; Cheng, Carina; de Lera Acedo, Eloy; Dillon, Joshua S.; Ewall-Wice, Aaron; Fadana, Gcobisa; Fagnoni, Nicolas; Fritz, Randall; Furlanetto, Steve R.; Glendenning, Brian; Greig, Bradley; Grobbelaar, Jasper; Hazelton, Bryna J.; Hewitt, Jacqueline N.; Hickish, Jack; Jacobs, Daniel C.; Julius, Austin; Kariseb, MacCalvin; Kohn, Saul A.; Lekalake, Telalo; Liu, Adrian; Loots, Anita; MacMahon, David; Malan, Lourence; Malgas, Cresshim; Maree, Matthys; Martinot, Zachary; Mathison, Nathan; Matsetela, Eunice; Mesinger, Andrei; Morales, Miguel F.; Neben, Abraham R.; Patra, Nipanjana; Pieterse, Samantha; Pober, Jonathan C.; Razavi-Ghods, Nima; Ringuette, Jon; Robnett, James; Rosie, Kathryn; Sell, Raddwine; Smith, Craig; Syce, Angelo; Tegmark, Max; Thyagarajan, Nithyanandan; Williams, Peter K. G.; Zheng, Haoxuan
2017-04-01
The Hydrogen Epoch of Reionization Array (HERA) is a staged experiment to measure 21 cm emission from the primordial intergalactic medium (IGM) throughout cosmic reionization (z = 6-12), and to explore earlier epochs of our Cosmic Dawn (z ˜ 30). During these epochs, early stars and black holes heated and ionized the IGM, introducing fluctuations in 21 cm emission. HERA is designed to characterize the evolution of the 21 cm power spectrum to constrain the timing and morphology of reionization, the properties of the first galaxies, the evolution of large-scale structure, and the early sources of heating. The full HERA instrument will be a 350-element interferometer in South Africa consisting of 14 m parabolic dishes observing from 50 to 250 MHz. Currently, 19 dishes have been deployed on site and the next 18 are under construction. HERA has been designated as an SKA Precursor instrument. In this paper, we summarize HERA’s scientific context and provide forecasts for its key science results. After reviewing the current state of the art in foreground mitigation, we use the delay-spectrum technique to motivate high-level performance requirements for the HERA instrument. Next, we present the HERA instrument design, along with the subsystem specifications that ensure that HERA meets its performance requirements. Finally, we summarize the schedule and status of the project. We conclude by suggesting that, given the realities of foreground contamination, current-generation 21 cm instruments are approaching their sensitivity limits. HERA is designed to bring both the sensitivity and the precision to deliver its primary science on the basis of proven foreground filtering techniques, while developing new subtraction techniques to unlock new capabilities. The result will be a major step toward realizing the widely recognized scientific potential of 21 cm cosmology.
Operating manual for the R200 downhole recorder with husky hunter retriever
Johnson, Roy A.; Rorabaugh, James I.
1988-01-01
The R200 Downhole Recorder is a battery-powered device that, when placed in a well casing, monitors water levels for a period of up to 1 year. This instrument measures a 1- to 70-foot range of water levels. These water-level data can be retrieved through use of a commercially available portable microcomputer. The R200 Downhole Recorder was developed at the U.S. Geological Survey 's Hydrologic Instrumentation Facility, Stennis Space Center, Mississippi. This operating manual describes the R200 Downhole Recorder, provides initial set-up instructions, and gives directions for on-site operation. Design specifications and routine maintenance steps are included. The R200 data-retriever program is a user-friendly, menu-driven program. The manual guides the user through the procedures required to perform specific operations. Numerous screens are reproduced in the text with a discussion of user input for desired responses. Help is provided for specific problems. (USGS)
Operating manual for the R200 downhole recorder with Tandy 102 retriever
Johnson, Roy A.; Rorabaugh, James I.
1988-01-01
The R200 Downhole Recorder is a battery-powered device that, when placed in a well casing, monitors water levels for a period of up to 1 year. This instrument measures a 1- to 70-ft range of water levels. These water level data can be retrieved through use of a commercially available portable microcomputer. The R200 Downhole Recorder was developed at the U. S. Geological Survey 's Hydrologic Instrumentation Facility, Stennis Space Center, Mississippi. This operating manual describes the R200 Downhole Recorder, provides initial set-up instructions, and gives directions for on-site operation. Design specifications and routine maintenance steps are included. The R200 data-retriever program is a user-friendly, menu-driven program. The manual guides the user through the procedures required to perform specific operations. Numerous screens are reproduced in the text with a discussion of user input for desired responses. Help is provided for specific problems. (USGS)
Simon, Stephane; Lumley, Philip; Tomson, Phillip; Pertot, Wilhelm-Joseph; Machtou, Pierre
2008-03-01
Crown down preparation is the most known and described technique since the introduction of Nickel Titanium (NiTi) rotary instruments in endodontics. This technique gives good results but has limitations, such as not addressing the initial anatomy of oval or dumb-bell shaped canals. The specific design of the Protaper instruments allows use of them with a different technique and, specifically, with a brushing motion in the body of the canal. The recent introduction of hand Protaper files has expanded the range of application of this system, especially in curved canals. The 'hybrid technique', using rotary and hand files, and the advantages of the combination of both instruments, are clearly described in this article. Used with this technique, the Protaper is a very safe system to use, and more controllable, for both inexperienced and experienced practitioners alike, than other systems. To understand the precautions needed with rotary files, and how to use them to preserve the anatomy of the canal and get a tapered shaping, even in severely curved canals.
The Wide Field/Planetary Camera 2 (WFPC-2) molecular adsorber
NASA Technical Reports Server (NTRS)
Barengoltz, Jack; Moore, Sonya; Soules, David; Voecks, Gerald
1995-01-01
A device has been developed at the Jet Propulsion Laboratory, California Institute of Technology, for the adsorption of contaminants inside a space instrument during flight. The molecular adsorber was developed for use on the Wide Field Planetary Camera 2, and it has been shown to perform at its design specifications in the WFPC-2. The basic principle of the molecular adsorber is a zeolite-coated ceramic honeycomb. The arrangement is efficient for adsorption and also provides the needed rigidity to retain the special zeolite coating during the launch vibrational environment. The adsorber, on other forms, is expected to be useful for all flight instruments sensitive to internal sources of contamination. Typically, some internal contamination is unavoidable. A common design solution is to increase the venting to the exterior. However, for truly sensitive instruments, the external contamination environment is more severe. The molecular adsorber acts as a one-way vent to solve this problem. Continued development is planned for this device.
Measuring patient-perceived hospital service quality: a conceptual framework.
Pai, Yogesh P; Chary, Satyanarayana T
2016-04-18
Purpose - Although measuring healthcare service quality is not a new phenomenon, the instruments used to measure are timeworn. With the shift in focus to patient centric processes in hospitals and recognizing healthcare to be different compared to other services, service quality measurement needs to be tuned specifically to healthcare. The purpose of this paper is to design a conceptual framework for measuring patient perceived hospital service quality (HSQ), based on existing service quality literature. Design/methodology/approach - Using HSQ theories, expanding existing healthcare service models and literature, a conceptual framework is proposed to measure HSQ. The paper outlines patient perceived service quality dimensions. Findings - An instrument for measuring HSQ dimensions is developed and compared with other service quality measuring instruments. The latest dimensions are in line with previous studies, but a relationship dimension is added. Practical implications - The framework empowers managers to assess healthcare quality in corporate, public and teaching hospitals. Originality/value - The paper helps academics and practitioners to assess HSQ from a patient perspective.
NASA Astrophysics Data System (ADS)
Munro, Rosemary; Lang, Rüdiger; Klaes, Dieter; Poli, Gabriele; Retscher, Christian; Lindstrot, Rasmus; Huckle, Roger; Lacan, Antoine; Grzegorski, Michael; Holdak, Andriy; Kokhanovsky, Alexander; Livschitz, Jakob; Eisinger, Michael
2016-03-01
The Global Ozone Monitoring Experiment-2 (GOME-2) flies on the Metop series of satellites, the space component of the EUMETSAT Polar System. In this paper we will provide an overview of the instrument design, the on-ground calibration and characterization activities, in-flight calibration, and level 0 to 1 data processing. The current status of the level 1 data is presented and points of specific relevance to users are highlighted. Long-term level 1 data consistency is also discussed and plans for future work are outlined. The information contained in this paper summarizes a large number of technical reports and related documents containing information that is not currently available in the published literature. These reports and documents are however made available on the EUMETSAT web pages and readers requiring more details than can be provided in this overview paper will find appropriate references at relevant points in the text.
NASA Astrophysics Data System (ADS)
Munro, R.; Lang, R.; Klaes, D.; Poli, G.; Retscher, C.; Lindstrot, R.; Huckle, R.; Lacan, A.; Grzegorski, M.; Holdak, A.; Kokhanovsky, A.; Livschitz, J.; Eisinger, M.
2015-08-01
The Global Ozone Monitoring Experiment-2 (GOME-2) flies on the Metop series of satellites, the space component of the EUMETSAT Polar System. In this paper we will provide an overview of the instrument design, the on-ground calibration and characterisation activities, in-flight calibration, and level 0 to 1 data processing. The quality of the level 1 data is presented and points of specific relevance to users are highlighted. Long-term level 1 data consistency is also discussed and plans for future work are outlined. The information contained in this paper summarises a large number of technical reports and related documents containing information that is not currently available in the published literature. These reports and documents are however made available on the EUMETSAT web pages (http://www.eumetsat.int) and readers requiring more details than can be provided in this overview paper will find appropriate references at relevant points in the text.
THE POTENTIAL APPLICATION OF FIRESAT DATA TO ASSESSMENT OF HUMAN EXPOSURES TO WILDFIRE EMISSIONS
FireSat is a proposed NASA mission that will obtain global coverage of the occurrence of wildfires. The specifications for FireSat are described in detail by Levine et al., (1991). Because of limitations of instruments (designed for other purposes) in existing satellites, new in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mauk, F.J.; Kimball, B.; Davis, R.A.
1984-01-01
The Brazoria seismic network, instrumentation, design, and specifications are described. The data analysis procedures are presented. Seismicity is described in relation to the Pleasant Bayou production history. Seismicity originating near the chemical plant east of the geopressured/geothermal well is discussed. (MHR)
Hypoxia, Monitoring, and Mitigation System
2015-08-01
Oxygen Saturation Measured via Pulse - Oximeter SRS Software Requirements Specification SW Software TI Texas Instruments uPROC Micro-Processor USAARL...Financial) Table of Figures Figure 1: Pulse OX custom module...Tasks 3, 4 and 5 have not been exercised. Sensor definition testing continued on the custom pulse -ox design. Additional refinement on the pulse
An Informatics Approach to Establishing a Sustainable Public Health Community
ERIC Educational Resources Information Center
Kriseman, Jeffrey Michael
2012-01-01
This work involved the analysis of a public health system, and the design, development and deployment of enterprise informatics architecture, and sustainable community methods to address problems with the current public health system. Specifically, assessment of the Nationally Notifiable Disease Surveillance System (NNDSS) was instrumental in…
A Developmental Inventory of Sources of Stress.
ERIC Educational Resources Information Center
Higbee, Jeanne L.; Dwinell, Patricia L.
The Developmental Inventory of Sources of Stress (DISS) is an instructional tool designed to assist counselors, advisors, and faculty in reducing stress among college students (specifically, high risk college freshmen, although it can be utilized effectively with any college student population). The instrument focuses on sources of stress over…
Dual Sensory Loss and Its Impact on Everyday Competence
ERIC Educational Resources Information Center
Brennan, Mark; Horowitz, Amy; Su, Ya-ping
2005-01-01
Purpose: This study examined the relation of dual and single sensory impairments, within the context of cognitive function, by using the framework of everyday competence in terms of the probability of difficulty with specific personal and instrumental activities of daily living (ADLs and IADLs, respectively). Design and Methods: The Longitudinal…
Research pressure instrumentation for NASA Space Shuttle main engine, modification no. 6
NASA Technical Reports Server (NTRS)
Anderson, P. J.; Johnson, R. L.
1984-01-01
Research concerning the utilization of silicon piezoresistive strain sensing technology for space shuttle main engine applications is reported. The following specific topics were addressed: (1) transducer design and materials, (2) silicon piezoresistor characterization at cryogenic temperatures, (3) chip mounting characterization, and (4) frequency response optimization.
The L2000DX Analyzer (dimensions: 9 x 9.5 x 4.25 in.) is a field-portable ion-specific electrode instrument, weighing approximately 5 lb 12 oz, designed to quantify concentrations of PCBS, chlorinated solvents, and pesticides in soils, water, transformer oils, and surface wipes. ...
Preparing project managers for faster-better-cheaper robotic planetary missions
NASA Technical Reports Server (NTRS)
Gowler, P.; Atkins, K.
2003-01-01
The authors have developed and implemented a week-long workshop for Jet Propulsion Laboratory Project Managers, designed around the development phases of the JPL Project Life Cycle. The workshop emphasizes the specific activities and deliverables that pertain to JPL managers of NASA robotic space exploration and instrument development projects.
NASA Astrophysics Data System (ADS)
Mauk, F. J.; Kimball, B.; Davis, R. A.
The Brazoria seismic network, instrumentation, design, and specifications are described. The data analysis procedures are presented. Seismicity is described in relation to the Pleasant Bayou production history. Seismicity originating near the chemical plant east of the geopressured/geothermal well is discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-26
... addition, the requestor/petitioner shall provide a brief explanation of the bases for the contention and a..., malfunctions, or accident initiators not considered in the design and licensing bases. The proposed amendment... technical specifications (TSs) requirements related to primary containment isolation instrumentation in...
40 CFR 65.163 - Other records.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Detailed schematics, design specifications of the control device, and piping and instrumentation diagrams... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65... bypass lines that could divert a vent stream away from the control device and to the atmosphere, the...
Development and Exploratory Validation of an Organizational Efficacy Scale
ERIC Educational Resources Information Center
Bohn, James G.
2010-01-01
Although many instruments have been developed to measure organizational constructs such as citizenship, climate, and organization-based esteem, to date no scale has been designed specifically to measure efficacy at the organizational level. Tools to measure organizational efficacy in a business context have been recommended for over two decades.…
A Systematic Approach to Evaluating Career Education Materials at the Local Level.
ERIC Educational Resources Information Center
Peat, Marwick, Mitchell and Co., Washington, DC.
The document contains an assessment instrument, developed by three teams of educators, designed to assist career education practitioners in identifying, classifying, and evaluating career education instructional materials to determine the usefulness of a particular unit of material in a specific local situation. It also contains suggestions of…
Empirical Validation and Application of the Computing Attitudes Survey
ERIC Educational Resources Information Center
Dorn, Brian; Elliott Tew, Allison
2015-01-01
Student attitudes play an important role in shaping learning experiences. However, few validated instruments exist for measuring student attitude development in a discipline-specific way. In this paper, we present the design, development, and validation of the computing attitudes survey (CAS). The CAS is an extension of the Colorado Learning…
Galyean, Anne A; Filliben, James J; Holbrook, R David; Vreeland, Wyatt N; Weinberg, Howard S
2016-11-18
Asymmetric flow field flow fractionation (AF 4 ) has several instrumental factors that may have a direct effect on separation performance. A sensitivity analysis was applied to ascertain the relative importance of AF 4 primary instrument factor settings for the separation of a complex environmental sample. The analysis evaluated the impact of instrumental factors namely, cross flow, ramp time, focus flow, injection volume, and run buffer concentration on the multi-angle light scattering measurement of natural organic matter (NOM) molar mass (MM). A 2 (5-1) orthogonal fractional factorial design was used to minimize analysis time while preserving the accuracy and robustness in the determination of the main effects and interactions between any two instrumental factors. By assuming that separations resulting in smaller MM measurements would be more accurate, the analysis produced a ranked list of effects estimates for factors and interactions of factors based on their relative importance in minimizing the MM. The most important and statistically significant AF 4 instrumental factors were buffer concentration and cross flow. The least important was ramp time. A parallel 2 (5-2) orthogonal fractional factorial design was also employed on five environmental factors for synthetic natural water samples containing silver nanoparticles (NPs), namely: NP concentration, NP size, NOM concentration, specific conductance, and pH. None of the water quality characteristic effects or interactions were found to be significant in minimizing the measured MM; however, the interaction between NP concentration and NP size was an important effect when considering NOM recovery. This work presents a structured approach for the rigorous assessment of AF 4 instrument factors and optimal settings for the separation of complex samples utilizing efficient orthogonal factional factorial design and appropriate graphical analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Garcia-Belmonte, Germà
2017-06-01
Spatial visualization is a well-established topic of education research that has allowed improving science and engineering students' skills on spatial relations. Connections have been established between visualization as a comprehension tool and instruction in several scientific fields. Learning about dynamic processes mainly relies upon static spatial representations or images. Visualization of time is inherently problematic because time can be conceptualized in terms of two opposite conceptual metaphors based on spatial relations as inferred from conventional linguistic patterns. The situation is particularly demanding when time-varying signals are recorded using displaying electronic instruments, and the image should be properly interpreted. This work deals with the interplay between linguistic metaphors, visual thinking and scientific instrument mediation in the process of interpreting time-varying signals displayed by electronic instruments. The analysis draws on a simplified version of a communication system as example of practical signal recording and image visualization in a physics and engineering laboratory experience. Instrumentation delivers meaningful signal representations because it is designed to incorporate a specific and culturally favored time view. It is suggested that difficulties in interpreting time-varying signals are linked with the existing dual perception of conflicting time metaphors. The activation of specific space-time conceptual mapping might allow for a proper signal interpretation. Instruments play then a central role as visualization mediators by yielding an image that matches specific perception abilities and practical purposes. Here I have identified two ways of understanding time as used in different trajectories through which students are located. Interestingly specific displaying instruments belonging to different cultural traditions incorporate contrasting time views. One of them sees time in terms of a dynamic metaphor consisting of a static observer looking at passing events. This is a general and widespread practice common in the contemporary mass culture, which lies behind the process of making sense to moving images usually visualized by means of movie shots. In contrast scientific culture favored another way of time conceptualization (static time metaphor) that historically fostered the construction of graphs and the incorporation of time-dependent functions, as represented on the Cartesian plane, into displaying instruments. Both types of cultures, scientific and mass, are considered highly technological in the sense that complex instruments, apparatus or machines participate in their visual practices.
A versatile retarding potential analyzer for nano-satellite platforms.
Fanelli, L; Noel, S; Earle, G D; Fish, C; Davidson, R L; Robertson, R V; Marquis, P; Garg, V; Somasundaram, N; Kordella, L; Kennedy, P
2015-12-01
The design of the first retarding potential analyzer (RPA) built specifically for use on resource-limited cubesat platforms is described. The size, mass, and power consumption are consistent with the limitations of a nano-satellite, but the performance specifications are commensurate with those of RPAs flown on much larger platforms. The instrument is capable of measuring the ion density, temperature, and the ram component of the ion velocity in the spacecraft reference frame, while also providing estimates of the ion composition. The mechanical and electrical designs are described, as are the operating modes, command and data structure, and timing scheme. Test data obtained using an ion source inside a laboratory vacuum chamber are presented to validate the performance of the new design.
The EarthCARE Simulator (Invited)
NASA Astrophysics Data System (ADS)
Donovan, D. P.; van Zadellhoff, G.; Lajas, D.; Eisinger, M.; Franco, R.
2009-12-01
In recent years, the value of multisensor remote sensing techniques applied to cloud, aerosol, radiation and precipitation studies has become clear. For example, combinations of instruments including lidars and/or radars have proved very useful for profile retrievals of cloud macrophysical and microphysical properties. This is amply illustrated by various results from the ARM (and similar) sites as well as from results derived using the Cloudsat/CALIPSO/A-train combination of instruments. The Earth Clouds Aerosol and Radiation Explorer (EarthCARE) mission is a combined ESA/JAXA mission scheduled for launch in 2013 and has been designed with sensor-synergy playing a driving role in its scientific applications. The EarthCARE mission consists of a cloud profiling Doppler radar, a high-spectral-resolution lidar, a cloud/aerosol imager and a three-view broadband radiometer. As part of the mission development process, a detailed end-to-end multisensor simulation system has been developed. The EarthCARE Simulator (ECSIM) consists of a modular general framework populated by various models. The models within ECSIM are grouped according to the following scheme: 1) Scene creation models (3D atmospheric scene definition) 2) Orbit models (orbit and orientation of the platform as it overflies the scene) 3) Forward models (calculate the signal impinging on the telescope/antenna of the instrument(s) in question) 4) Instrument models (calculate the instrument response to the signals calculated by the Forward models) 5) Retrieval models (invert the instrument signals to recover relevant geophysical information) Within the default ECSIM models crude instrument specific parameterizations (i.e. empirically based Z vs IWC relationships) are avoided. Instead, the radiative transfer forward models are kept as separate as possible from the instrument models. In order to accomplish this, the atmospheric scenes are specified in high detail (i.e. bin resolved cloud size distribution are stored) and the relevant wavelength dependent optical properties are stored in a separate database. This helps insure that all the instruments involved in the simulation are treated in a consistent fashion and that the physical relationships between the various measurements are realistically captured (something that using instrument specific parameterizations relationships can not guarantee). As a consequence, ECSIM's modular structure makes it straightforward to add new instruments (thus expanding ECSIM beyond the EarthCARE instrument suite) and also makes ECSIM well-suited for physically based retrieval algorithm development. In this talk, we will introduce ECSIM and emphasize the philosophy behind its design. We will also give a brief overview on the various default models. Finally, we will present several examples of how ECSIM can and is being used for purposes ranging from general radiative transfer calculations to instrument performance estimation and synergistic algorithm development and characterization.
NASA Astrophysics Data System (ADS)
Unsal, E.; Drum, J.; Yucel, O.; Nugay, I. I.; Yalcin, B.; Cakmak, M.
2012-02-01
This paper describes the design and performance of a new instrument to track temporal changes in physical parameters during the drying behavior of solutions, as well as curing of monomers. This real-time instrument follows in-plane and out-of-plane birefringence, weight, thickness, and surface temperature during the course of solidification of coatings and films through solvent evaporation and thermal or photocuring in a controlled atmosphere. It is specifically designed to simulate behavior of polymer solutions inside an industrial size, continuous roll-to-roll solution casting line and other coating operations where resins are subjected to ultraviolet (UV) curing from monomer precursors. Controlled processing parameters include air speed, temperature, initial cast thickness, and solute concentration, while measured parameters are thickness, weight, film temperature, in-plane and out-of-plane birefringence. In this paper, we illustrate the utility of this instrument with solution cast and dried poly (amide-imide)/DMAc (Dimethylacetamide) solution, water based black paint, and organo-modified clay/NMP (N-Methylpyrrolidone) solution. In addition, the physical changes that take place during UV photo polymerization of a monomer are tracked. This instrument is designed to be generic and it can be used for tracking any drying/swelling/solidification systems including paper, foodstuffs such as; grains, milk as well as pharmaceutical thin paste and slurries.
The Inner Magnetospheric Imager (IMI): Instrument heritage and orbit viewing analysis
NASA Astrophysics Data System (ADS)
Wilson, Gordon R.
1992-12-01
For the last two years an engineering team in the Program Development Office at MSFC has been doing design studies for the proposed Inner Magnetospheric Imager (IMI) mission. This team had a need for more information about the instruments that this mission would carry so that they could get a better handle on instrument volume, mass, power, and telemetry needs as well as information to help assess the possible cost of such instruments and what technology development they would need. To get this information, an extensive literature search was conducted as well as interviews with several members of the IMI science working group. The results of this heritage survey are summarized below. There was also a need to evaluate the orbits proposed for this mission from the stand point of their suitability for viewing the various magnetospheric features that are planned for this mission. This was accomplished by first, identifying the factors which need to be considered in selecting an orbit, second, translating these considerations into specific criteria, and third, evaluating the proposed orbits against these criteria. The specifics of these criteria and the results of the orbit analysis are contained in the last section of this report.
The challenges of integrating instrumentation with inflatable aerodynamic decelerators
NASA Astrophysics Data System (ADS)
Swanson, Gregory T.; Cassell, Alan M.; Hughes, Stephen J.; Johnson, R. Keith; Calomino, Anthony M.
New Entry, Decent, and Landing (EDL) technologies are being explored to facilitate the landing of high mass vehicles. Current EDL technologies are limited due to mass and volume constraints dictated by launch vehicle fairings. Therefore, past and present technologies are now being considered to provide a mass and volume efficient solution, including Inflatable Aerodynamic Decelerators (IADs). To better define the instrumentation challenges posed by IAD technology development, a survey was conducted to identify valuable measurements for ground and flight testing of the flexible materials and structures used in their design. From this survey many sensing technologies and systems were explored specific to the stacked torus IAD, resulting in a down-selection to the most viable prospects. The majority of these systems, including wireless data acquisition, were then rapid prototyped and evaluated during component level testing to determine the best integration techniques specific to a 3m and 6m diameter stacked toroid IAD. Each sensing system was then integrated in support of the Hypersonic Inflatable Aerodynamic Decelerator ground test campaign. In this paper these IAD instrumentation systems are described along with their challenges in comparison to traditional rigid aeroshell systems. Requirements resulting from the survey are listed and instrumentation integration techniques and data acquisition are discussed.
The Inner Magnetospheric Imager (IMI): Instrument heritage and orbit viewing analysis
NASA Technical Reports Server (NTRS)
Wilson, Gordon R.
1992-01-01
For the last two years an engineering team in the Program Development Office at MSFC has been doing design studies for the proposed Inner Magnetospheric Imager (IMI) mission. This team had a need for more information about the instruments that this mission would carry so that they could get a better handle on instrument volume, mass, power, and telemetry needs as well as information to help assess the possible cost of such instruments and what technology development they would need. To get this information, an extensive literature search was conducted as well as interviews with several members of the IMI science working group. The results of this heritage survey are summarized below. There was also a need to evaluate the orbits proposed for this mission from the stand point of their suitability for viewing the various magnetospheric features that are planned for this mission. This was accomplished by first, identifying the factors which need to be considered in selecting an orbit, second, translating these considerations into specific criteria, and third, evaluating the proposed orbits against these criteria. The specifics of these criteria and the results of the orbit analysis are contained in the last section of this report.
The MUSE project face to face with reality
NASA Astrophysics Data System (ADS)
Caillier, P.; Accardo, M.; Adjali, L.; Anwand, H.; Bacon, Roland; Boudon, D.; Brotons, L.; Capoani, L.; Daguisé, E.; Dupieux, M.; Dupuy, C.; François, M.; Glindemann, A.; Gojak, D.; Hansali, G.; Hahn, T.; Jarno, A.; Kelz, A.; Koehler, C.; Kosmalski, J.; Laurent, F.; Le Floch, M.; Lizon, J.-L.; Loupias, M.; Manescau, A.; Migniau, J. E.; Monstein, C.; Nicklas, H.; Parès, L.; Pécontal-Rousset, A.; Piqueras, L.; Reiss, R.; Remillieux, A.; Renault, E.; Rupprecht, G.; Streicher, O.; Stuik, R.; Valentin, H.; Vernet, J.; Weilbacher, P.; Zins, G.
2012-09-01
MUSE (Multi Unit Spectroscopic Explorer) is a second generation instrument built for ESO (European Southern Observatory) to be installed in Chile on the VLT (Very Large Telescope). The MUSE project is supported by a European consortium of 7 institutes. After the critical turning point of shifting from the design to the manufacturing phase, the MUSE project has now completed the realization of its different sub-systems and should finalize its global integration and test in Europe. To arrive to this point many challenges had to be overcome, many technical difficulties, non compliances or procurements delays which seemed at the time overwhelming. Now is the time to face the results of our organization, of our strategy, of our choices. Now is the time to face the reality of the MUSE instrument. During the design phase a plan was provided by the project management in order to achieve the realization of the MUSE instrument in specification, time and cost. This critical moment in the project life when the instrument takes shape and reality is the opportunity to look not only at the outcome but also to see how well we followed the original plan, what had to be changed or adapted and what should have been.
Solid state light engines for bioanalytical instruments and biomedical devices
NASA Astrophysics Data System (ADS)
Jaffe, Claudia B.; Jaffe, Steven M.
2010-02-01
Lighting subsystems to drive 21st century bioanalysis and biomedical diagnostics face stringent requirements. Industrywide demands for speed, accuracy and portability mean illumination must be intense as well as spectrally pure, switchable, stable, durable and inexpensive. Ideally a common lighting solution could service these needs for numerous research and clinical applications. While this is a noble objective, the current technology of arc lamps, lasers, LEDs and most recently light pipes have intrinsic spectral and angular traits that make a common solution untenable. Clearly a hybrid solution is required to service the varied needs of the life sciences. Any solution begins with a critical understanding of the instrument architecture and specifications for illumination regarding power, illumination area, illumination and emission wavelengths and numerical aperture. Optimizing signal to noise requires careful optimization of these parameters within the additional constraints of instrument footprint and cost. Often the illumination design process is confined to maximizing signal to noise without the ability to adjust any of the above parameters. A hybrid solution leverages the best of the existing lighting technologies. This paper will review the design process for this highly constrained, but typical optical optimization scenario for numerous bioanalytical instruments and biomedical devices.
The LAMP instrument at the Linac Coherent Light Source free-electron laser
NASA Astrophysics Data System (ADS)
Osipov, Timur; Bostedt, Christoph; Castagna, J.-C.; Ferguson, Ken R.; Bucher, Maximilian; Montero, Sebastian C.; Swiggers, Michele L.; Obaid, Razib; Rolles, Daniel; Rudenko, Artem; Bozek, John D.; Berrah, Nora
2018-03-01
The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusive metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.
Measuring Networking as an Outcome Variable in Undergraduate Research Experiences
Hanauer, David I.; Hatfull, Graham
2015-01-01
The aim of this paper is to propose, present, and validate a simple survey instrument to measure student conversational networking. The tool consists of five items that cover personal and professional social networks, and its basic principle is the self-reporting of degrees of conversation, with a range of specific discussion partners. The networking instrument was validated in three studies. The basic psychometric characteristics of the scales were established by conducting a factor analysis and evaluating internal consistency using Cronbach’s alpha. The second study used a known-groups comparison and involved comparing outcomes for networking scales between two different undergraduate laboratory courses (one involving a specific effort to enhance networking). The final study looked at potential relationships between specific networking items and the established psychosocial variable of project ownership through a series of binary logistic regressions. Overall, the data from the three studies indicate that the networking scales have high internal consistency (α = 0.88), consist of a unitary dimension, can significantly differentiate between research experiences with low and high networking designs, and are related to project ownership scales. The ramifications of the networking instrument for student retention, the enhancement of public scientific literacy, and the differentiation of laboratory courses are discussed. PMID:26538387
Heffernan, Catherine; Jenkinson, Crispin
2005-06-01
Health-related quality-of-life measures have been increasingly used in research into neurological disorders in recent years. The aim of this paper is to provide an objective appraisal of the evidence in regard to disease-specific quality-of-life measures used in research on health interventions for three degenerative neurological disorders: multiple sclerosis, motor neurone disease/amyotrophic lateral sclerosis and Parkinson's disease. A comprehensive search strategy was developed to include nine relevant electronic databases. Only studies pertaining to patient-based outcome measurements in multiple sclerosis, motor neurone disease and Parkinson's disease were included. We identified 76 eligible studies. As studies consisted of descriptive and cross-sectional survey study designs, results were reported qualitatively rather than in the form of a meta-analysis. Four disease-specific measures were found for Parkinson's disease, 11 for multiple sclerosis and one for motor neurone disease. We conclude that health-related quality-of-life measures are useful in assessing the impact of treatments and interventions for neurological disorders. However, further research is needed on the development of instruments using psychometric methods and on the validation, utilization and responsiveness of instruments to change.
Spherical grating spectrometers
NASA Astrophysics Data System (ADS)
O'Donoghue, Darragh; Clemens, J. Christopher
2014-07-01
We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.
NASA Astrophysics Data System (ADS)
Cazorla, M.; Wolfe, G. M.; Bailey, S. A.; Swanson, A. K.; Arkinson, H. L.; Hanisco, T. F.
2015-02-01
The NASA In Situ Airborne Formaldehyde (ISAF) instrument is a high-performance laser-based detector for gas-phase formaldehyde (HCHO). ISAF uses rotational-state specific laser excitation at 353 nm for laser-induced fluorescence (LIF) detection of HCHO. A number of features make ISAF ideal for airborne deployment, including (1) a compact, low-maintenance fiber laser, (2) a single-pass design for stable signal response, (3) a straightforward inlet design, and (4) a stand-alone data acquisition system. A full description of the instrument design is given, along with detailed performance characteristics. The accuracy of reported mixing ratios is ±10% based on calibration against IR and UV absorption of a primary HCHO standard. Precision at 1 Hz is typically better than 20% above 100 pptv, with uncertainty in the signal background contributing most to variability at low mixing ratios. The 1 Hz detection limit for a signal / noise ratio of 2 is 36 pptv for 10 mW of laser power, and the e fold time response at typical sample flow rates is 0.19 s. ISAF has already flown on several field missions and platforms with excellent results.
NASA Astrophysics Data System (ADS)
Cazorla, M.; Wolfe, G. M.; Bailey, S. A.; Swanson, A. K.; Arkinson, H. L.; Hanisco, T. F.
2014-08-01
The NASA In Situ Airborne Formaldehyde (ISAF) instrument is a high-performance laser-based detector for gas phase formaldehyde (HCHO). ISAF uses rotational-state specific laser excitation at 353 nm for laser-induced fluorescence (LIF) detection of HCHO. A number of features make ISAF ideal for airborne deployment, including (1) a compact, low-maintenance fiber laser, (2) a single-pass design for stable signal response, (3) a straightforward inlet design, and (4) a standalone data acquisition system. A full description of the instrument design is given, along with detailed performance characteristics. The accuracy of reported mixing ratios is ±10% based on calibration against IR and UV absorption of a primary HCHO standard. Precision at 1 Hz is typically better than 20% above 100 pptv, with uncertainty in the signal background contributing most to variability at low mixing ratios. The 1 Hz detection limit for a signal/noise ratio of 2 is 36 pptv for 10 mW of laser power, and the e-fold time response at typical sample flow rates is 0.19 s. ISAF has already flown on several field missions and platforms with excellent results.
SAGE III on ISS Lessons Learned on Thermal Interface Design
NASA Technical Reports Server (NTRS)
Davis, Warren
2015-01-01
The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument - the fifth in a series of instruments developed for monitoring vertical distribution of aerosols, ozone, and other trace gases in the Earth's stratosphere and troposphere - is currently scheduled for delivery to the International Space Station (ISS) via the SpaceX Dragon vehicle in 2016. The Instrument Adapter Module (IAM), one of many SAGE III subsystems, continuously dissipates a considerable amount of thermal energy during mission operations. Although a portion of this energy is transferred via its large radiator surface area, the majority must be conductively transferred to the ExPRESS Payload Adapter (ExPA) to satisfy thermal mitigation requirements. The baseline IAM-ExPA mechanical interface did not afford the thermal conductance necessary to prevent the IAM from overheating in hot on-orbit cases, and high interfacial conductance was difficult to achieve given the large span between mechanical fasteners, less than stringent flatness specifications, and material usage constraints due to strict contamination requirements. This paper will examine the evolution of the IAM-ExPA thermal interface over the course of three design iterations and will include discussion on design challenges, material selection, testing successes and failures, and lessons learned.
James Webb Space Telescope Project (JWST) Overview
NASA Technical Reports Server (NTRS)
Dutta, Mitra
2008-01-01
This presentation provides an overview of the James Webb Space Telescope (JWST) Project. The JWST is an infrared telescope designed to collect data in the cosmic dark zone. Specifically, the mission of the JWST is to study the origin and evolution of galaxies, stars and planetary systems. It is a deployable telescope with a 6.5 m diameter, segmented, adjustable primary mirror. outfitted with cryogenic temperature telescope and instruments for infrared performance. The JWST is several times more sensitive than previous telescope and other photographic and electronic detection methods. It hosts a near infrared camera, near infrared spectrometer, mid-infrared instrument and a fine guidance sensor. The JWST mission objection and architecture, integrated science payload, instrument overview, and operational orbit are described.
The solar physics Shuttle/Spacelab program and its relationship to studies of the flare build-up
NASA Technical Reports Server (NTRS)
Neupert, W. M.
1976-01-01
The main phase of solar physics (including flare-buildup) research on Shuttle/Spacelab during the 1980s centers around the use of facility instruments for multiple-user, multiple flight operations. Three main facilities are being considered: a meter-class optical telescope for visible and near-UV wavelengths, an EUV/XUV/soft X-ray facility, and a hard X-ray imaging facility (including a full-sun 5-600 keV spectrometer, a nuclear gamma ray spectrometer, and an X-ray polarimeter for the 5-100 keV range). Smaller instruments designed for specific observations and other classes of instruments such as solar monitors that are not on the facility level are also being considered.
New synchrotron powder diffraction facility for long-duration experiments
Murray, Claire A.; Potter, Jonathan; Day, Sarah J.; Baker, Annabelle R.; Thompson, Stephen P.; Kelly, Jon; Morris, Christopher G.; Tang, Chiu C.
2017-01-01
A new synchrotron X-ray powder diffraction instrument has been built and commissioned for long-duration experiments on beamline I11 at Diamond Light Source. The concept is unique, with design features to house multiple experiments running in parallel, in particular with specific stages for sample environments to study slow kinetic systems or processes. The instrument benefits from a high-brightness X-ray beam and a large area detector. Diffraction data from the commissioning work have shown that the objectives and criteria are met. Supported by two case studies, the results from months of measurements have demonstrated the viability of this large-scale instrument, which is the world’s first dedicated facility for long-term studies (weeks to years) using synchrotron radiation. PMID:28190992
NASA Astrophysics Data System (ADS)
Gómez-Sáenz-de-Tejada, Jaime; Toledo-Moreo, Rafael; Colodro-Conde, Carlos; Pérez-Lizán, David; Fernández-Conde, Jesús; Sánchez-Prieto, Sebastián.
2016-07-01
The Near Infrared Spectrograph and Photometer (NISP) is one of the instruments on board the ESA EUCLID mission. The Boot Software (BSW) is in charge of initialization and communications after a reset occurs at hard- ware level. The Universidad Politecnica de Cartagena and Instituto de Astrofisica de Canarias are responsible of the Instrument Control Unit of the NISP (NI-ICU) in the Euclid Consortium. The NI-ICU BSW is developed by Universidad de Alcaĺa, and its main functions are: communication with the S/C for memory management, self-tests and start of a patchable Application Software (ASW). This paper presents the NI-ICU BSW status of definition and design at the end of the Technical Specification phase.
Conceptual design of two-phase fluid mechanics and heat transfer facility for spacelab
NASA Technical Reports Server (NTRS)
North, B. F.; Hill, M. E.
1980-01-01
Five specific experiments were analyzed to provide definition of experiments designed to evaluate two phase fluid behavior in low gravity. The conceptual design represents a fluid mechanics and heat transfer facility for a double rack in Spacelab. The five experiments are two phase flow patterns and pressure drop, flow boiling, liquid reorientation, and interface bubble dynamics. Hardware was sized, instrumentation and data recording requirements defined, and the five experiments were installed as an integrated experimental package. Applicable available hardware was selected in the experiment design and total experiment program costs were defined.
New multivariable capabilities of the INCA program
NASA Technical Reports Server (NTRS)
Bauer, Frank H.; Downing, John P.; Thorpe, Christopher J.
1989-01-01
The INteractive Controls Analysis (INCA) program was developed at NASA's Goddard Space Flight Center to provide a user friendly, efficient environment for the design and analysis of control systems, specifically spacecraft control systems. Since its inception, INCA has found extensive use in the design, development, and analysis of control systems for spacecraft, instruments, robotics, and pointing systems. The (INCA) program was initially developed as a comprehensive classical design analysis tool for small and large order control systems. The latest version of INCA, expected to be released in February of 1990, was expanded to include the capability to perform multivariable controls analysis and design.
Facial measurements for frame design.
Tang, C Y; Tang, N; Stewart, M C
1998-04-01
Anthropometric data for the purpose of spectacle frame design are scarce in the literature. Definitions of facial features to be measured with existing systems of facial measurement are often not specific enough for frame design and manufacturing. Currently, for individual frame design, experienced personnel collect data with facial rules or instruments. A new measuring system is proposed, making use of a template in the form of a spectacle frame. Upon fitting the template onto a subject, most of the measuring references can be defined. Such a system can be administered by lesser-trained personnel and can be used for researches covering a larger population.
Single-mode waveguides for GRAVITY. I. The cryogenic 4-telescope integrated optics beam combiner
NASA Astrophysics Data System (ADS)
Perraut, K.; Jocou, L.; Berger, J. P.; Chabli, A.; Cardin, V.; Chamiot-Maitral, G.; Delboulbé, A.; Eisenhauer, F.; Gambérini, Y.; Gillessen, S.; Guieu, S.; Guerrero, J.; Haug, M.; Hausmann, F.; Joulain, F.; Kervella, P.; Labeye, P.; Lacour, S.; Lanthermann, C.; Lapras, V.; Le Bouquin, J. B.; Lippa, M.; Magnard, Y.; Moulin, T.; Noël, P.; Nolot, A.; Patru, F.; Perrin, G.; Pfuhl, O.; Pocas, S.; Poulain, S.; Scibetta, C.; Stadler, E.; Templier, R.; Ventura, N.; Vizioz, C.; Amorim, A.; Brandner, W.; Straubmeier, C.
2018-06-01
Context. Within the framework of the second-generation instrumentation of the Very Large Telescope Interferometer of the European Southern Observatory we have developed the four-telescope beam combiner in integrated optics. Aims: We optimized the performance of such beam combiners, for the first time in the near-infrared K band, for the GRAVITY instrument dedicated to the study of the close environment of the galactic centre black hole by precision narrow-angle astrometry and interferometric imaging. Methods: We optimized the design of the integrated optics chip and the manufacturing technology as well, to fulfil the very demanding throughput specification. We also designed an integrated optics assembly able to operate at 200 K in the GRAVITY cryostat to reduce thermal emission. Results: We manufactured about 50 beam combiners by silica-on-silicon etching technology. We glued the best combiners to single-mode fluoride fibre arrays that inject the VLTI light into the integrated optics beam combiners. The final integrated optics assemblies have been fully characterized in the laboratory and through on-site calibrations: their global throughput over the K band is higher than 55% and the instrumental contrast reaches more than 95% in polarized light, which is well within the GRAVITY specifications. Conclusions: While integrated optics technology is known to be mature enough to provide efficient and reliable beam combiners for astronomical interferometry in the H band, we managed to successfully extend it to the longest wavelengths of the K band and to manufacture the most complex integrated optics beam combiner in this specific spectral band.
Qualification of Laser Diode Arrays for Mercury Laser Altimeter Mission
NASA Technical Reports Server (NTRS)
Stephen, Mark; Vasilyev, Aleksey; Schafer, John; Allan, Graham R.
2004-01-01
NASA's requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. The MESSENGER mission is flying the Mercury Laser Altimeter (MLA) which is a diode-pumped Nd:YAG laser instrument designed to map the topography of Mercury. The environment imposed on the instrument by the orbital dynamics places special requirements on the laser diode arrays. In order to limit the radiative heating of the satellite from the surface of Mercury, the satellite is designed to have a highly elliptical orbit. The satellite will heat near perigee and cool near apogee. The laser power is cycled during these orbits so that the laser is on for only 30 minutes (perigee) in a 12 hour orbit. The laser heats 10 C while powered up and cools while powered down. In order to simulate these operational conditions, we designed a test to measure the LDA performance while being temperature and power cycled. Though the mission requirements are specific to NASA and performance requirements are derived from unique operating conditions, the results are general and widely applicable. We present results on the performance of twelve LDAs operating for several hundred million pulses. The arrays are 100 watt, quasi-CW, conductively-cooled, 808 nm devices. Prior to testing, we fully characterize each device to establish a baseline for individual array performance and status. Details of this characterization can be found in reference. Arrays are divided into four groups and subjected to the temperature and power cycling matrix are shown.
Optomechanical Design and Analysis Considerations on the Lunar Orbiter Laser Altimeter
NASA Technical Reports Server (NTRS)
Schmidt. Stephen; Mamakos, William; Matzinger, Elizabeth; Wall, Sheila
2007-01-01
This paper presents the mechanical design and analysis work completed on the Lunar Orbiter Laser Altimeter (LOLA). LOLA is one of six instruments on the Lunar Reconnaissance Orbiter (LRO), scheduled to launch in 2008. LOLA's main objective is to produce a high-resolution global lunar topographic model to aid in safe landings and enhance surface mobility in future exploration missions. LOLA will also look for evidence of ice water in the permanently shadowed regions around the lunar poles. Beryllium was chosen as the primary material for the LOLA Optical Transmitter Assembly to take advantage of the material's low mass density for light weight optical instrument design and for CTE matching of the refractive optical components. In addition, the thermal conductivity and specific heat of beryllium minimizes thermal gradients and thermal excursions. Special consideration must be made for the planning and preparation to fabricate beryllium components, as well as the preparation and cleaning of the components for gold plating. Assembly challenges include handling, precision cleaning and integration and testing. Structural analysis considerations include following General Environmental Verification Specification (GEVS) guidelines for GSFC payloads. The GEVS random environment for LOLA has an acceptance level of 10.0 Grms, which was analyzed for higher frequency transients. The low frequency transients were analyzed using a Mass Acceleration Curve to obtain an equivalent static loading. In addition, Structural-Thermal-Optical analysis, commonly referred to as STOP analysis, was completed to predict optical performance under the instrument's operational thermal environment. This included stress and distortion analysis on the receiver telescope lens.
Muratov, Sergei; Podbielski, Dominik W; Jack, Susan M; Ahmed, Iqbal Ike K; Mitchell, Levine A H; Baltaziak, Monika; Xie, Feng
2016-01-01
Introduction A primary objective of healthcare services is to improve patients' health and health-related quality of life (HRQoL). Glaucoma, which affects a substantial proportion of the world population, has a significant detrimental impact on HRQoL. Although there are a number of glaucoma-specific questionnaires to measure HRQoL, none is preference-based which prevent them from being used in health economic evaluation. The proposed study is aimed to develop a preference-based instrument that is capable of capturing important effects specific to glaucoma and treatments on HRQoL and is scored based on the patients' preferences. Methods A sequential, exploratory mixed methods design will be used to guide the development and evaluation of the HRQoL instrument. The study consists of several stages to be implemented sequentially: item identification, item selection, validation and valuation. The instrument items will be identified and selected through a literature review and the conduct of a qualitative study. Validation will be conducted to establish psychometric properties of the instrument followed by a valuation exercise to derive utility scores for the health states described. Ethics and dissemination This study has been approved by the Trillium Health Partners Research Ethics Board (ID number 753). All personal information will be de-identified with the identification code kept in a secured location including the rest of the study data. Only qualified and study-related personnel will be allowed to access the data. The results of the study will be distributed widely through peer-reviewed journals, conferences and internal meetings. PMID:28186941
Romero-García, Marta; de la Cueva-Ariza, Laura; Benito-Aracil, Llucia; Lluch-Canut, Teresa; Trujols-Albet, Joan; Martínez-Momblan, Maria Antonia; Juvé-Udina, Maria-Eulàlia; Delgado-Hito, Pilar
2018-06-01
The aim of this study was to develop and validate the Nursing Intensive-Care Satisfaction Scale to measures satisfaction with nursing care from the critical care patient's perspective. Instruments that measure satisfaction with nursing cares have been designed and validated without taking the patient's perspective into consideration. Despite the benefits and advances in measuring satisfaction with nursing care, none instrument is specifically designed to assess satisfaction in intensive care units. Instrument development. The population were all discharged patients (January 2013 - January 2015) from three Intensive Care Units of a third level hospital (N = 200). All assessment instruments were given to discharged patients and 48 hours later, to analyse the temporal stability, only the questionnaire was given again. The validation process of the scale included the analysis of internal consistency, temporal stability; validity of construct through a confirmatory factor analysis; and criterion validity. Reliability was 0.95. The intraclass correlation coefficient for the total scale was 0.83 indicating a good temporal stability. Construct validity showed an acceptable fit and factorial structure with four factors, in accordance with the theoretical model, being Consequences factor the best correlated with other factors. Criterion validity, presented a correlation between low and high (range: 0.42-0.68). The scale has been designed and validated incorporating the perspective of critical care patients. Thanks to its reliability and validity, this questionnaire can be used both in research and in clinical practice. The scale offers a possibility to assess and develop interventions to improve patient satisfaction with nursing care. © 2018 John Wiley & Sons Ltd.
Remote environmental sensor array system
NASA Astrophysics Data System (ADS)
Hall, Geoffrey G.
This thesis examines the creation of an environmental monitoring system for inhospitable environments. It has been named The Remote Environmental Sensor Array System or RESA System for short. This thesis covers the development of RESA from its inception, to the design and modeling of the hardware and software required to make it functional. Finally, the actual manufacture, and laboratory testing of the finished RESA product is discussed and documented. The RESA System is designed as a cost-effective way to bring sensors and video systems to the underwater environment. It contains as water quality probe with sensors such as dissolved oxygen, pH, temperature, specific conductivity, oxidation-reduction potential and chlorophyll a. In addition, an omni-directional hydrophone is included to detect underwater acoustic signals. It has a colour, high-definition and a low-light, black and white camera system, which it turn are coupled to a laser scaling system. Both high-intensity discharge and halogen lighting system are included to illuminate the video images. The video and laser scaling systems are manoeuvred using pan and tilt units controlled from an underwater computer box. Finally, a sediment profile imager is included to enable profile images of sediment layers to be acquired. A control and manipulation system to control the instruments and move the data across networks is integrated into the underwater system while a power distribution node provides the correct voltages to power the instruments. Laboratory testing was completed to ensure that the different instruments associated with the RESA performed as designed. This included physical testing of the motorized instruments, calibration of the instruments, benchmark performance testing and system failure exercises.
DSN radio science system design and testing for Voyager-Neptune encounter
NASA Technical Reports Server (NTRS)
Ham, N. C.; Rebold, T. A.; Weese, J. F.
1989-01-01
The Deep Space Network (DSN) Radio Science System presently implemented within the Deep Space Network was designed to meet stringent requirements imposed by the demands of the Voyager-Neptune encounter and future missions. One of the initial parameters related to frequency stability is discussed. The requirement, specification, design, and methodology for measuring this parameter are described. A description of special instrumentation that was developed for the test measurements and initial test data resulting from the system tests performed at Canberra, Australia and Usuda, Japan are given.
Use of MicroMaps for Satellite Validation and Potential UAV Applications
NASA Astrophysics Data System (ADS)
Connors, V. S.; Sachse, G. W.; Hopkins, P. E.; Morrow, W.; McMillan, W. W.
2005-12-01
The MicroMAPS instrument is a nadir-viewing, gas filter-correlated radiometer which operates in the 4.67 micrometer fundamental band of carbon monoxide. Originally designed and built for a space mission, this CO remote sensor is being flown in support of satellite validation and science instrument demonstrations for potential UAV applications. The MicroMAPS CO instrument was flown for the first time during the Summer-Fall 2004 on-board the Proteus aircraft, which is owned and operated by Scaled Composites, in Mojave, CA. The insturment system, flown on Proteus, was designed by a student team as a senior design project in the Aerospace Engineering Department, Virginia Tech, in Blacksburg, VA. This proposed design was reviewed and revised by Systems Engineers at NASA Langley; the final instrument system was integrated and tested at NASA LaRC in partnership with Scaled Composites and Virginia Space Grant Consortium, which supervised the fabrication of the nacelle which housed the instrument system on the right rear tail boom of Proteus. Full system integration and flight testing was performed at Scaled Composites, in Mojave, in June 2004. Its successful performance enabled participation in three international science missions: INTEX -NA over eastern North America in July 2004, ADRIEX over the Mediterranean region and EAQUATE over the United Kingdom region in September 2004, piggy-backing with the IPO-sponsored payload flown on Proteus. These flights resulted in nearly 100 hours of science measurements and in-flight calibrations. In parallel with the engineering devlopments, theoretical radiative transfer models were developed specifically for the MicroMAPS instrument system at the University of Virginia, Aerospace and Mechanical Engineering Department by a combined undergraduate and graduate student team. With techical support from Resonance Ltd. In June 2005, in Barrie, Canada, the MicroMAPS instrument was calibrated for the conditions underwhich the Summer-Fall 2004 flights occurred. The analyses of the calibration data, combined with the theoretical radiative transfer models, will provide the first data reduction for the science flights. These early results and comparisons with profile data from the NASA DC-8 and the coincident AIRS CO retrievals will be presented.
The development and testing of a qualitative instrument designed to assess critical thinking
NASA Astrophysics Data System (ADS)
Clauson, Cynthia Louisa
This study examined a qualitative approach to assess critical thinking. An instrument was developed that incorporates an assessment process based on Dewey's (1933) concepts of self-reflection and critical thinking as problem solving. The study was designed to pilot test the critical thinking assessment process with writing samples collected from a heterogeneous group of students. The pilot test included two phases. Phase 1 was designed to determine the validity and inter-rater reliability of the instrument using two experts in critical thinking, problem solving, and literacy development. Validity of the instrument was addressed by requesting both experts to respond to ten questions in an interview. The inter-rater reliability was assessed by analyzing the consistency of the two experts' scorings of the 20 writing samples to each other, as well as to my scoring of the same 20 writing samples. Statistical analyses included the Spearman Rho and the Kuder-Richardson (Formula 20). Phase 2 was designed to determine the validity and reliability of the critical thinking assessment process with seven science teachers. Validity was addressed by requesting the teachers to respond to ten questions in a survey and interview. Inter-rater reliability was addressed by comparing the seven teachers' scoring of five writing samples with my scoring of the same five writing samples. Again, the Spearman Rho and the Kuder-Richardson (Formula 20) were used to determine the inter-rater reliability. The validity results suggest that the instrument is helpful as a guide for instruction and provides a systematic method to teach and assess critical thinking while problem solving with students in the classroom. The reliability results show the critical thinking assessment instrument to possess fairly high reliability when used by the experts, but weak reliability when used by classroom teachers. A major conclusion was drawn that teachers, as well as students, would need to receive instruction in critical thinking and in how to use the assessment process in order to gain more consistent interpretations of the six problem-solving steps. Specific changes needing to be made in the instrument to improve the quality are included.
Steimle, Jerrod A; Groover, Michael T; Webb, Brad A; Ceccarelli, Brian J
2018-01-01
Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation.
Instrumentation Cables Test Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muna, Alice Baca; LaFleur, Chris Bensdotter
A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteriamore » 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift and fluctuate, while the thermoplastic insulated cables, the instrument reading fell off-scale rapidly. From an operational point of view, the latter failure characteristics would likely be identified as a failure from the effects of fire, while the former may result in inaccurate readings.« less
A Versatile Planetary Radio Science Microreceiver
NASA Technical Reports Server (NTRS)
Fry, Craig D.; Rosenberg, T. J.
1999-01-01
We have developed a low-power. programmable radio "microreceiver" that combines the functionality of two science instruments: a Relative Ionospheric Opacity Meter (riometer) and a swept-frequency, VTF/HF radio spectrometer. The radio receiver, calibration noise source, data acquisition and processing, and command and control functions are all contained on a single circuit board. This design is suitable for miniaturizing as a complete flight instrument. Several of the subsystems were implemented in a field-programmable gate array (FPGA), including the receiver detector, the control logic, and the data acquisition and processing blocks. Considerable efforts were made to reduce the power consumption of the instrument, and eliminate or minimize RF noise and spurious emissions generated by the receiver's digital circuitry. A prototype instrument was deployed at McMurdo Station, Antarctica, and operated in parallel with a traditional riometer instrument for approximately three weeks. The attached paper (accepted for publication by Radio Science) describes in detail the microreceiver theory of operation, performance specifications and test results.
Fiber optic interferometry for industrial process monitoring and control applications
NASA Astrophysics Data System (ADS)
Marcus, Michael A.
2002-02-01
Over the past few years we have been developing applications for a high-resolution (sub-micron accuracy) fiber optic coupled dual Michelson interferometer-based instrument. It is being utilized in a variety of applications including monitoring liquid layer thickness uniformity on coating hoppers, film base thickness uniformity measurement, digital camera focus assessment, optical cell path length assessment and imager and wafer surface profile mapping. The instrument includes both coherent and non-coherent light sources, custom application dependent optical probes and sample interfaces, a Michelson interferometer, custom electronics, a Pentium-based PC with data acquisition cards and LabWindows CVI or LabView based application specific software. This paper describes the development evolution of this instrument platform and applications highlighting robust instrument design, hardware, software, and user interfaces development. The talk concludes with a discussion of a new high-speed instrument configuration, which can be utilized for high speed surface profiling and as an on-line web thickness gauge.
Contamination control program for the Cosmic Background Explorer
NASA Technical Reports Server (NTRS)
Barney, Richard D.
1991-01-01
Each of the three state of the art instruments flown aboard NASA's Cosmic Background Explorer (COBE) were designed, fabricated, and integrated using unique contamination control procedures to ensure accurate characterization of the diffuse radiation in the universe. The most stringent surface level cleanliness specifications ever attempted by NASA were required by the Diffuse Infrared Background Experiment (DRIBE) which is located inside a liquid helium cooled dewar along with the Far Infrared Absolute Spectrophotometer (FIRAS). The DRIBE instrument required complex stray radiation suppression that defined a cold primary optical baffle system surface cleanliness level of 100A. The cleanliness levels of the cryogenic FIRAS instrument and the Differential Microwave Radiometer (DMR) which were positioned symmetrically around the dewar were less stringent ranging from 300 to 500A. To achieve these instrument cleanliness levels, the entire flight spacecraft was maintained at level 500A throughout each phase of development. The COBE contamination control program is described along with the difficulties experienced in maintaining the cleanliness quality of personnel and flight hardware throughout instrument assembly.
Creation of Anatomically Accurate Computer-Aided Design (CAD) Solid Models from Medical Images
NASA Technical Reports Server (NTRS)
Stewart, John E.; Graham, R. Scott; Samareh, Jamshid A.; Oberlander, Eric J.; Broaddus, William C.
1999-01-01
Most surgical instrumentation and implants used in the world today are designed with sophisticated Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) software. This software automates the mechanical development of a product from its conceptual design through manufacturing. CAD software also provides a means of manipulating solid models prior to Finite Element Modeling (FEM). Few surgical products are designed in conjunction with accurate CAD models of human anatomy because of the difficulty with which these models are created. We have developed a novel technique that creates anatomically accurate, patient specific CAD solids from medical images in a matter of minutes.
Development and Sizing of the JWST Integrated Science Instrument Module (ISIM) Metering Structure
NASA Technical Reports Server (NTRS)
Johnston, John; Kunt, Cengiz; Bartoszyk, Andrew; Hendricks, Steve; Cofie, Emmanuel
2006-01-01
The JWST Integrated Science Instrument Module (ISIM) includes a large metering structure (approx. 2m x 2m x 1.5m) that houses the science instruments and guider. Stringent dimensional stability and repeatability requirements combined with mass limitations led to the selection of a composite bonded frame design comprised of biased laminate tubes. Even with the superb material specific stiffness, achieving the required frequency for the given mass allocations in conjunction with severe spatial limitations imposed by the instrument complement has proven challenging. In response to the challenge, the ISIM structure team considered literally over 100 primary structure topology and kinematic mount configurations, and settled on a concept comprised of over 70 m of tubes, over 50 bonded joint assemblies, and a "split bi-pod" kinematic mount configuration. In this paper, we review the evolution of the ISIM primary structure topology and kinematic mount configuration to the current baseline concept.
Martin, Linda M; Triscari, Robert; Boisvert, Rosemary; Hipp, Kristi; Gersten, Jennifer; West, Rachel C; Kisling, Elizabeth; Donham, Aaron; Kollar, Naomi; Escobar, Patricia
2015-01-01
We developed and investigated the psychometric properties of the Lifestyle History Questionnaire (LHQ), a self-report instrument designed to measure the extent of occupational dysfunction attributable to substance abuse. The instrument was developed using concepts in the ecological models of occupational therapy and in the work of William L. White, who defined addiction culture in terms of the patterns of life in context. We analyzed data from two field tests using both classical test theory and item response theory. The final version of the instrument has 70 items, 1 unifying construct, and 8 subscales. We found it to be valid and reliable (α=.93) for measuring the extent of occupational dysfunction and specific areas of strengths and weaknesses. The LHQ is a promising new instrument, the first of its kind to measure occupational dysfunction in context for people with substance addictions. Copyright © 2015 by the American Occupational Therapy Association, Inc.
Preliminary Investigation of the Flying Qualities of Airplanes
NASA Technical Reports Server (NTRS)
Soule, H A
1940-01-01
The National Advisory Committee for Aeronautics is undertaking an investigation of the flying qualities of airplanes. The work consists in the determination of the significant qualities susceptible of measurement, the development of the instruments required to make the measurements, and the accumulation of data on the flying qualities of existing airplanes, which data are to serve as a basis for quantitative specifications for the flying qualities of future designs. A tentative schedule of measurable flying qualities has been prepared and the instruments needed for their measurements have been assembled. A trial of the schedule and the instruments has been made using the Stinson SR-8e airplane. The results showed that, although the original schedule and instruments are basically satisfactory some further development is required to eliminate nonessential items and to expedite flight testing. The report describes and discusses the work done with this airplane.
A Quantitative Evaluation of Dissolved Oxygen Instrumentation
NASA Technical Reports Server (NTRS)
Pijanowski, Barbara S.
1971-01-01
The implications of the presence of dissolved oxygen in water are discussed in terms of its deleterious or beneficial effects, depending on the functional consequences to those affected, e.g., the industrialist, the oceanographer, and the ecologist. The paper is devoted primarily to an examination of the performance of five commercially available dissolved oxygen meters. The design of each is briefly reviewed and ease or difficulty of use in the field described. Specifically, the evaluation program treated a number of parameters and user considerations including an initial check and trial calibration for each instrument and a discussion of the measurement methodology employed. Detailed test results are given relating to the effects of primary power variation, water-flow sensitivity, response time, relative accuracy of dissolved-oxygen readout, temperature accuracy (for those instruments which included this feature), error and repeatability, stability, pressure and other environmental effects, and test results obtained in the field. Overall instrument performance is summarized comparatively by chart.
CRISP-Psychometric Assessment of Postdivorce Stress/Adjustment in Children.
ERIC Educational Resources Information Center
Aronson, David M.; Baum, Steven K.
A new psychometric instrument for measuring the impact of divorce on elementary school age children was developed: the Child's Report of the Impact of Separation by Parents (CRISP). This structured projective test was specifically designed to assess children's postdivorce stress/adjustment. An initial version of the CRISP was administered to 99…
Program Evaluation in Gifted Education. Essential Readings in Gifted Education Series
ERIC Educational Resources Information Center
Callahan, Carolyn M., Ed.; Reis, Sally M., Ed.
2004-01-01
The readings in this ready-reference report on specific program evaluations, offer critical guidance in the development and utilization of instruments for assessing gifted and talented programs, and are designed to stimulate the discussion of issues surrounding the evaluation of gifted programs. Key features include: (1) Carolyn M. Callahan's…
ERIC Educational Resources Information Center
LoPresto, Michael C.; Hubble-Zdanowski, Jennifer
2012-01-01
The "Life in the Universe Survey" is a twelve-question assessment instrument. Largely based on the factors of the Drake equation, it is designed to survey students' initial estimates of its factors and to gauge how estimates change with instruction. The survey was used in sections of a seminar course focusing specifically on life in the universe…
Local/State Bilingual Project. 1981-82 Final Technical Report. Appendixes.
ERIC Educational Resources Information Center
Austin Independent School District, TX. Office of Research and Evaluation.
The 1981-82 Local/State Bilingual Program Technical Report addresses the evaluation questions of the Local/State Bilingual Program Evaluation Design. It is organized into six appendixes. Each appendix reports the information collected by a specific measure. Each appendix consists of (1) an instrument description, (2) purpose of the measure, (3)…
Protective Factor Screening for Prevention Practice: Sensitivity and Specificity of the Dessa-Mini
ERIC Educational Resources Information Center
Shapiro, Valerie B.; Kim, B. K. Elizabeth; Robitaille, Jennifer L.; LeBuffe, Paul A.
2017-01-01
The Devereux Student Strengths Assessment Mini (DESSA-Mini; Naglieri, LeBuffe, & Shapiro, 2011/2014) was designed to overcome practical obstacles to universal prevention screening. This article seeks to determine whether an entirely strength-based, 8-item screening instrument achieves technical accuracy in routine practice. Data come from a…
Perceptions Of School Culture (POSC) User Manual and Technical Report
ERIC Educational Resources Information Center
Cowley, Kimberly S.; Voelkel, Susan; Finch, Nicole L.; Meehan, Merrill L.
2005-01-01
The Perceptions Of School Culture (POSC) instrument was designed to measure the perceptions of a school staff regarding various dimensions of school culture contained in a hypothesized model of school cultural change. Specifically, this model posits that the development of a high-performance learning culture is influenced by school vision and…
Experimental design for drifting buoy Lagrangian test
NASA Technical Reports Server (NTRS)
Saunders, P. M.
1975-01-01
A test of instrumentation fabricated to measure the performance of a free drifting buoy as a (Lagrangian) current meter is described. Specifically it is proposed to distinguish between the trajectory of a drogued buoy and the trajectory of the water at the level of the drogue by measuring the flow relative to the drogue.
Setting Professional Goals: Causing Teachers To Want Inservice Education.
ERIC Educational Resources Information Center
Bey, Theresa M.
Since the major intent of inservice education is to enrich and modify the efforts of every teacher, guidelines are essential. One specific goal-setting process designed for any teacher to conduct a self-assessment of teaching and non-teaching responsibilities is the Complete Procedural Review (CPR). This instrument sets forth teachers' duties and…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-05
.../petitioner shall provide a brief explanation of the bases for the contention and a concise statement of the.... The fuel rod design bases are established to satisfy the general and specific safety criteria..., ``Primary Containment Isolation Instrumentation,'' by deleting channel check Surveillance Requirement 3.3.6...
Using the 4MAT Framework to Design a Problem-Based Learning Biostatistics Course
ERIC Educational Resources Information Center
Nowacki, Amy S.
2011-01-01
The study presents and applies the 4MAT theoretical framework to educational planning to transform a biostatistics course into a problem-based learning experience. Using a four-question approach, described are specific activities/materials utilized at both the class and course levels. Two web-based instruments collected data regarding student…
TOPEX SDR Processing, October 1998. Volume 4
NASA Technical Reports Server (NTRS)
Lee, Jeffrey E.; Lockwood, Dennis W.
2003-01-01
This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Sensor Data Record (SDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.
ERIC Educational Resources Information Center
Paoloni, Paola Verónica; Vaja, Arabela Beatriz; Muñoz, Verónica Lilian
2014-01-01
Introduction: This paper aims at describing the psychometric features of the Achievement Emotions Questionnaire (AEQ), focusing specifically on the section that measures class emotions. From a theoretical perspective, this instrument was designed based on the control-value theory of achievement emotions. Therefore, a description of the…
Development and Validation of the Inventory of Depression and Anxiety Symptoms (IDAS)
ERIC Educational Resources Information Center
Watson, David; O'Hara, Michael W.; Simms, Leonard J.; Kotov, Roman; Chmielewski, Michael; McDade-Montez, Elizabeth A.; Gamez, Wakiza; Stuart, Scott
2007-01-01
The authors describe a new self-report instrument, the Inventory of Depression and Anxiety Symptoms (IDAS), which was designed to assess specific symptom dimensions of major depression and related anxiety disorders. They created the IDAS by conducting principal factor analyses in 3 large samples (college students, psychiatric patients, community…
Maternal Work Status and Pregnancy Outcomes: A Pilot.
ERIC Educational Resources Information Center
Pitzer, Martha S.
Investigated were effects of maternal work status and parity on specific outcomes in maternal psychology and physiology and infant physiology. In addition, the study design and the usefulness of instruments were evaluated, and the feasibility of subject recruitment and retention was assessed. Subjects were 20 women between 18 and 35 years of age…
Eye-Safe Lidar System for Pesticide Spray Drift Measurement
Gregorio, Eduard; Rocadenbosch, Francesc; Sanz, Ricardo; Rosell-Polo, Joan R.
2015-01-01
Spray drift is one of the main sources of pesticide contamination. For this reason, an accurate understanding of this phenomenon is necessary in order to limit its effects. Nowadays, spray drift is usually studied by using in situ collectors which only allow time-integrated sampling of specific points of the pesticide clouds. Previous research has demonstrated that the light detection and ranging (lidar) technique can be an alternative for spray drift monitoring. This technique enables remote measurement of pesticide clouds with high temporal and distance resolution. Despite these advantages, the fact that no lidar instrument suitable for such an application is presently available has appreciably limited its practical use. This work presents the first eye-safe lidar system specifically designed for the monitoring of pesticide clouds. Parameter design of this system is carried out via signal-to-noise ratio simulations. The instrument is based on a 3-mJ pulse-energy erbium-doped glass laser, an 80-mm diameter telescope, an APD optoelectronic receiver and optomechanically adjustable components. In first test measurements, the lidar system has been able to measure a topographic target located over 2 km away. The instrument has also been used in spray drift studies, demonstrating its capability to monitor the temporal and distance evolution of several pesticide clouds emitted by air-assisted sprayers at distances between 50 and 100 m. PMID:25658395
MicroMAPS CO Measurements over North America and Europe during Summer-Fall 2004
NASA Astrophysics Data System (ADS)
Connors, V. S.; Hopkins, P. E.; Reichle, H. G.; Morrow, W. H.; McMillan, W. W.; Sandy, M.
2006-12-01
The MicroMAPS instrument is a nadir-viewing, gas filter-correlated radiometer which operating in the 4.67 micrometer fundamental band of carbon monoxide. Originally designed and built for a space mission, this CO remote sensor is being flown in support of satellite validation and science instrument demonstrations for potential UAV applications. The MicroMAPS instrument system, as flown on Proteus, was designed by a senior student design project in the Aerospace Engineering Department, Virginia Tech, in Blacksburg, VA. and then revised by Systems Engineers at NASA Langley. The final instrument system was integrated and tested at NASA LaRC, in partnership with Scaled Composites and Virginia Space Grant Consortium (VSGC). VSGC supervised the fabrication of the nacelle that houses the instrument system on the right rear tail boom of Proteus. Full system integration and flight testing was performed at Scaled Composites, in Mojave, in June 2004. Its successful performance enabled participation in four international science missions on Proteus: in 2004, INTEX -NA over eastern North America in July, ADRIEX over the Mediterranean region and EAQUATE over the United Kingdom region in September,and TWP-ICE over Darwin, Australia and the surrounding oceans in Jan-Feb 2006. These flights resulted in nearly 300 hours of data. In parallel with the engineering developments, theoretical radiative transfer models were developed specifically for the MicroMAPS instrument system at the University of Virginia, Mechanical Engineering Department by a combined undergraduate and graduate student team. With technical support from Resonance Ltd. in June 2005, the MicroMAPS instrument was calibrated for the conditions under which the Summer-Fall 2004 flights occurred. The analyses of the calibration data, combined with the theoretical radiative transfer models, provide the first data reduction for the science flights reported here. These early results and comparisons with profile data from the NASA DC-8, the coincident AIRS CO retrievals, and selected CO measurements from the MOZAIC program will be presented.
MicroMAPS CO Measurements over North America and Europe during Summer-Fall 2004
NASA Technical Reports Server (NTRS)
Connors, Vickie S.; Hopkins, Patrick E.; Reichle, Henry G., Jr.; Morrow, William H.; McMillan, Wallace; Sandy, Mary L.
2006-01-01
The MicroMAPS instrument is a nadir-viewing, gas filter-correlated radiometer which operating in the 4.67 micrometer fundamental band of carbon monoxide. Originally designed and built for a space mission, this CO remote sensor is being flown in support of satellite validation and science instrument demonstrations for potential UAV applications. The MicroMAPS instrument system, as flown on Proteus, was designed by a senior student design project in the Aerospace Engineering Department, Virginia Tech, in Blacksburg, VA. and then revised by Systems Engineers at NASA Langley. The final instrument system was integrated and tested at NASA LaRC, in partnership with Scaled Composites and Virginia Space Grant Consortium (VSGC). VSGC supervised the fabrication of the nacelle that houses the instrument system on the right rear tail boom of Proteus. Full system integration and flight testing was performed at Scaled Composites, in Mojave, in June 2004. Its successful performance enabled participation in four international science missions on Proteus: in 2004, INTEX -NA over eastern North America in July, ADRIEX over the Mediterranean region and EAQUATE over the United Kingdom region in September,and TWP-ICE over Darwin, Australia and the surrounding oceans in Jan-Feb 2006. These flights resulted in nearly 300 hours of data. In parallel with the engineering developments, theoretical radiative transfer models were developed specifically for the MicroMAPS instrument system at the University of Virginia, Mechanical Engineering Department by a combined undergraduate and graduate student team. With technical support from Resonance Ltd. in June 2005, the MicroMAPS instrument was calibrated for the conditions under which the Summer-Fall 2004 flights occurred. The analyses of the calibration data, combined with the theoretical radiative transfer models, provide the first data reduction for the science flights reported here. These early results and comparisons with profile data from the NASA DC-8, the coincident AIRS CO retrievals, and selected CO measurements from the MOZAIC program will be presented.
Advances in handheld FT-IR instrumentation
NASA Astrophysics Data System (ADS)
Arnó, Josep; Cardillo, Len; Judge, Kevin; Frayer, Maxim; Frunzi, Michael; Hetherington, Paul; Levy, Dustin; Oberndorfer, Kyle; Perec, Walter; Sauer, Terry; Stein, John; Zuidema, Eric
2012-06-01
FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenges of ConOps (Concepts of Operation) in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the advances resulting from a project designed to overcome the challenges associated with miniaturizing FT-IR instruments. The project team developed a disturbance-corrected permanently aligned cube corner interferometer for improved robustness and optimized opto-mechanical design to maximize optical throughput and signal-to-noise ratios. Thermal management and heat flow were thoroughly modeled and studied to isolate sensitive components from heat sources and provide the widest temperature operation range. Similarly, extensive research on mechanical designs and compensation techniques to protect against shock and vibration will be discussed. A user interface was carefully created for military and emergency response applications to provide actionable information in a visual, intuitive format. Similar to the HazMatID family of products, state-of-the-art algorithms were used to quickly identify the chemical composition of complex samples based on the spectral information. This article includes an overview of the design considerations, tests results, and performance validation of the mechanical ruggedness, spectral, and thermal performance.
Okan, Orkan; Lopes, Ester; Bollweg, Torsten Michael; Bröder, Janine; Messer, Melanie; Bruland, Dirk; Bond, Emma; Carvalho, Graça S; Sørensen, Kristine; Saboga-Nunes, Luis; Levin-Zamir, Diane; Sahrai, Diana; Bittlingmayer, Uwe H; Pelikan, Jürgen M; Thomas, Malcolm; Bauer, Ullrich; Pinheiro, Paulo
2018-01-22
Health literacy is an important health promotion concern and recently children and adolescents have been the focus of increased academic attention. To assess the health literacy of this population, researchers have been focussing on developing instruments to measure their health literacy. Compared to the wider availability of instruments for adults, only a few tools are known for younger age groups. The objective of this study is to systematically review the field of generic child and adolescent health literacy measurement instruments that are currently available. A systematic literature search was undertaken in five databases (PubMed, CINAHL, PsycNET, ERIC, and FIS) on articles published between January 1990 and July 2015, addressing children and adolescents ≤18 years old. Eligible articles were analysed, data was extracted, and synthesised according to review objectives. Fifteen generic health literacy measurement instruments for children and adolescents were identified. All, except two, are self-administered instruments. Seven are objective measures (performance-based tests), seven are subjective measures (self-reporting), and one uses a mixed-method measurement. Most instruments applied a broad and multidimensional understanding of health literacy. The instruments were developed in eight different countries, with most tools originating in the United States (n = 6). Among the instruments, 31 different components related to health literacy were identified. Accordingly, the studies exhibit a variety of implicit or explicit conceptual and operational definitions, and most instruments have been used in schools and other educational contexts. While the youngest age group studied was 7-year-old children within a parent-child study, there is only one instrument specifically designed for primary school children and none for early years. Despite the reported paucity of health literacy research involving children and adolescents, an unexpected number of health literacy measurement studies in children's populations was found. Most instruments tend to measure their own specific understanding of health literacy and not all provide sufficient conceptual information. To advance health literacy instruments, a much more standardised approach is necessary including improved reporting on the development and validation processes. Further research is required to improve health literacy instruments for children and adolescents and to provide knowledge to inform effective interventions.
NASA Astrophysics Data System (ADS)
Lee, Yong Sam; Kim, Sang Hyuk; Mihn, Byeong-Hee
2016-09-01
We analyze the design and specifications of the Sun-and-Stars Time-Determining group of instruments (Ilseong-jeongsi-ui, 日星定時儀) made during the Joseon dynasty. According to the records of the Sejong Sillok (Veritable Records of King Sejong), Sun-and-Stars Time-Determining Instruments measure the solar time of day and the sidereal time of night through three rings and an alidade. One such instrument, the Simplified Time-Determining Instrument (So-jeongsi-ui, 小定時儀), is made without the essential component for alignment with the celestial north pole. Among this group of instruments, only two bronze Hundred-Interval-Ring Sundials (Baekgak-hwan-Ilgu, 百刻環日晷) currently exist. A comparison of the functions of these two relics with two Time-Determining Instruments suggests that the Hundred-Interval-Ring Sundial is a Simplified Sundial (So-ilyeong, 小日影), as recorded in the Sejong Sillok and the Seongjong Sillok (Veritable Records of King Seongjong). Furthermore, the Simplified Sundial is a model derived from the Simplified Time-Determining Instrument. During the King Sejong reign, the Sun-and-Stars Time-Determining Instruments were used in military camps of the kingdom’s frontiers, in royal ancestral rituals, and in royal astronomical observatories.
NASA Technical Reports Server (NTRS)
1985-01-01
The most promising new technology for scientific research is America's Space Transportation System; the space shuttle and its companion facility, Spacelab. Spacelab is a versatile laboratory designed specifically to accommodate scientists and their instruments in low-Earth orbit. In a space laboratory, scientists can perform experiments that are impossible on Earth. They can also use very large instruments aboard the Shuttle, with the added benefit of bringing all their equipment, experiment samples, and data home for analysis. Spacelab 2 is one in a series of missions that gives the world's scientists a chance to do research in a well-equipped laboratory in space.
Fourier Transform Methods. Chapter 4
NASA Technical Reports Server (NTRS)
Kaplan, Simon G.; Quijada, Manuel A.
2015-01-01
This chapter describes the use of Fourier transform spectrometers (FTS) for accurate spectrophotometry over a wide spectral range. After a brief exposition of the basic concepts of FTS operation, we discuss instrument designs and their advantages and disadvantages relative to dispersive spectrometers. We then examine how common sources of error in spectrophotometry manifest themselves when using an FTS and ways to reduce the magnitude of these errors. Examples are given of applications to both basic and derived spectrophotometric quantities. Finally, we give recommendations for choosing the right instrument for a specific application, and how to ensure the accuracy of the measurement results..
NASA Astrophysics Data System (ADS)
Ryan, James M.; Bancroft, Christopher; Bloser, Peter; Bravar, Ulisse; Fourguette, Dominique; Frost, Colin; Larocque, Liane; McConnell, Mark L.; Legere, Jason; Pavlich, Jane; Ritter, Greg; Wassick, Greg; Wood, Joshua; Woolf, Richard
2010-08-01
We have developed, fabricated and tested a prototype imaging neutron spectrometer designed for real-time neutron source location and identification. Real-time detection and identification is important for locating materials. These materials, specifically uranium and transuranics, emit neutrons via spontaneous or induced fission. Unlike other forms of radiation (e.g. gamma rays), penetrating neutron emission is very uncommon. The instrument detects these neutrons, constructs images of the emission pattern, and reports the neutron spectrum. The device will be useful for security and proliferation deterrence, as well as for nuclear waste characterization and monitoring. The instrument is optimized for imaging and spectroscopy in the 1-20 MeV range. The detection principle is based upon multiple elastic neutron-proton scatters in organic scintillator. Two detector panel layers are utilized. By measuring the recoil proton and scattered neutron locations and energies, the direction and energy spectrum of the incident neutrons can be determined and discrete and extended sources identified. Event reconstruction yields an image of the source and its location. The hardware is low power, low mass, and rugged. Its modular design allows the user to combine multiple units for increased sensitivity. We will report the results of laboratory testing of the instrument, including exposure to a calibrated Cf-252 source. Instrument parameters include energy and angular resolution, gamma rejection, minimum source identification distances and times, and projected effective area for a fully populated instrument.
Implant positioning in TKA: comparison between conventional and patient-specific instrumentation.
Ferrara, Ferdinando; Cipriani, Antonio; Magarelli, Nicola; Rapisarda, Santi; De Santis, Vincenzo; Burrofato, Aaron; Leone, Antonio; Bonomo, Lorenzo
2015-04-01
The number of total knee arthroplasty (TKA) procedures continuously increases, with good to excellent results. In the last few years, new surgical techniques have been developed to improve prosthesis positioning. In this context, patient-specific instrumentation is included. The goal of this study was to compare the perioperative parameters and the spatial positioning of prosthetic components in TKA procedures performed with patient-specific instrumentation vs traditional TKA. In this prospective comparative randomized study, 15 patients underwent TKA with 3-dimensional magnetic resonance imaging (MRI) preoperative planning (patient-specific instrumentation group) and 15 patients underwent traditional TKA (non-patient-specific instrumentation group). All patients underwent postoperative computed tomography (CT) examination. In the patient-specific instrumentation group, preoperative data planning regarding femoral and tibial bone resection was correlated with intraoperative measurements. Surgical time, length of hospitalization, and intraoperative and postoperative bleeding were compared between the 2 groups. Positioning of implants on postoperative CT was assessed for both groups. Data planned with 3-dimensional MRI regarding the depth of bone cuts showed good to excellent correlation with intraoperative measurements. The patient-specific instrumentation group showed better perioperative outcomes and good correlation between the spatial positioning of prosthetic components planned preoperatively and that seen on postoperative CT. Less variability was found in the patient-specific instrumentation group than in the non-patient-specific instrumentation group in spatial orientation of prosthetic components. Preoperative planning with 3-dimensional MRI in TKA has a better perioperative outcome compared with the traditional method. Use of patient-specific instrumentation can also improve the spatial positioning of both prosthetic components. Copyright 2015, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Jansen, Daniel J.
Teacher efficacy continues to be an important area of study in educational research. This study tested an instrument designed to assess the perceived efficacy of agricultural education teachers when engaged in lessons involving mathematics instruction. The study population of Oregon and Washington agricultural educators utilized in the validation of the instrument revealed important demographic findings and specific results related to teacher efficacy for the study population. An instrument was developed from the assimilation of three scales previously used and validated in efficacy research. Participants' mathematics teaching efficacy was assessed using a portion of the Mathematics Teaching Efficacy Beliefs Instrument (MTEBI), and personal mathematics efficacy was evaluated by the mathematics self-belief instrument which was derived from the Betz and Hackett's Mathematics Self-Efficacy Scale. The final scale, the Teachers' Sense of Efficacy Scale (TSES) created by Tschannen-Moran and Woolfolk Hoy, examined perceived personal teaching efficacy. Structural equation modeling was used as the statistical analyses tool to validate the instrument and examine correlations between efficacy constructs used to determine potential professional development needs of the survey population. As part of the data required for validation of the Mathematics Enhancement Teaching Efficacy instrument, demographic information defining the population of Oregon and Washington agricultural educators was obtained and reported. A hypothetical model derived from teacher efficacy literature was found to be an acceptable model to verify construct validity and determine strength of correlations between the scales that defined the instrument. The instrument produced an alpha coefficient of .905 for reliability. Both exploratory and confirmatory factor analyses were used to verify construct and discriminate validity. Specifics results related to the survey population of agricultural educators concluded that personal mathematics efficacy has a stronger correlation with mathematics teaching efficacy than personal teaching efficacy of teachers for this population. The implications of such findings suggest that professional development and pre-service preparation should be more focused on mathematics content knowledge rather than pedagogical knowledge when the objective is to enhance mathematics in interdisciplinary lessons.
Multi-Parameter Aerosol Scattering Sensor
NASA Technical Reports Server (NTRS)
Greenberg, Paul S.; Fischer, David G.
2011-01-01
This work relates to the development of sensors that measure specific aerosol properties. These properties are in the form of integrated moment distributions, i.e., total surface area, total mass, etc., or mathematical combinations of these moment distributions. Specifically, the innovation involves two fundamental features: a computational tool to design and optimize such sensors and the embodiment of these sensors in actual practice. The measurement of aerosol properties is a problem of general interest. Applications include, but are not limited to, environmental monitoring, assessment of human respiratory health, fire detection, emission characterization and control, and pollutant monitoring. The objectives for sensor development include increased accuracy and/or dynamic range, the inclusion in a single sensor of the ability to measure multiple aerosol properties, and developing an overall physical package that is rugged, compact, and low in power consumption, so as to enable deployment in harsh or confined field applications, and as distributed sensor networks. Existing instruments for this purpose include scattering photometers, direct-reading mass instruments, Beta absorption devices, differential mobility analyzers, and gravitational samplers. The family of sensors reported here is predicated on the interaction of light and matter; specifically, the scattering of light from distributions of aerosol particles. The particular arrangement of the sensor, e.g. the wavelength(s) of incident radiation, the number and location of optical detectors, etc., can be derived so as to optimize the sensor response to aerosol properties of practical interest. A key feature of the design is the potential embodiment as an extremely compact, integrated microsensor package. This is of fundamental importance, as it enables numerous previously inaccessible applications. The embodiment of these sensors is inherently low maintenance and high reliability by design. The novel and unique features include the underlying computational underpinning that allows the optimization for specific applications, and the physical embodiment that affords the construction of a compact, durable, and reliable integrated package. The advantage appears in the form of increased accuracy relative to existing instruments, and the applications enabled by the physical attributes of the resulting configuration
Visual display angles of conventional and a remotely piloted aircraft.
Kamine, Tovy Haber; Bendrick, Gregg A
2009-04-01
Instrument display separation and proximity are important human factor elements used in the design and grouping of aircraft instrument displays. To assess display proximity in practical operations, the viewing visual angles of various displays in several conventional aircraft and in a remotely piloted vehicle were assessed. The horizontal and vertical instrument display visual angles from the pilot's eye position were measured in 12 different types of conventional aircraft, and in the ground control station (GCS) of a remotely piloted aircraft (RPA). A total of 18 categories of instrument display were measured and compared. In conventional aircraft almost all of the vertical and horizontal visual display angles lay within a "cone of easy eye movement" (CEEM). Mission-critical instruments particular to specific aircraft types sometimes displaced less important instruments outside the CEEM. For the RPA, all horizontal visual angles lay within the CEEM, but most vertical visual angles lay outside this cone. Most instrument displays in conventional aircraft were consistent with display proximity principles, but several RPA displays lay outside the CEEM in the vertical plane. Awareness of this fact by RPA operators may be helpful in minimizing information access cost, and in optimizing RPA operations.
Thermo Scientific Sulfur Dioxide Analyzer Instrument Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Springston, S. R.
The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO2 + hυ1 →SO2 *→SO2 + hυ2 The emitted light is proportional to the concentration of SO2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers throughmore » the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. BNL has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.« less
Gussy, M; Kilpatrick, N
2006-09-01
To pilot the use of a multidimensional/hierarchical measurement instrument called the self-description questionnaire II to determine whether specific areas of self-concept in a group of adolescents with cleft lip and palate would be affected by their condition when compared with a normative sample. The self-concept of 23 adolescents with a cleft of the lip and palate was compared to an Australian normative sample. Adolescents attending the dental department of a paediatric hospital in Australia. The main outcome measure was a self-report questionnaire (102 items) with 10 domain-specific scales and a global measure of general self-concept. When compared to the normative data the study group showed significant differences in 4 of the 11 domain-specific scales: Parent Relations (P < 0.001), Physical Abilities (P < 0.001), Opposite-Sex Relations (P < 0.01) and Physical Appearance (P < 0.01) self-concepts. These differences were in a positive direction. Global self-concept as measured by the General Self scale was not significantly different from the normative sample. These results suggest that adolescents with clefts of the lip and palate have normative if not better self-concept than their peers. The study also suggests that having a cleft of the lip and palate has specific rather than broad associations with psychosocial adjustment. This justifies the use of instruments designed to assess specific areas of self-concept rather than more global measures.
Multichamber Multipotentiostat System for Cellular Microphysiometry.
Lima, Eduardo A; Snider, Rachel M; Reiserer, Ronald S; McKenzie, Jennifer R; Kimmel, Danielle W; Eklund, Sven E; Wikswo, John P; Cliffel, David E
2014-12-01
Multianalyte microphysiometry is a powerful technique for studying cellular metabolic flux in real time. Monitoring several analytes concurrently in a number of individual chambers, however, requires specific instrumentation that is not available commercially in a single, compact, benchtop form at an affordable cost. We developed a multipotentiostat system capable of performing simultaneous amperometric and potentiometric measurements in up to eight individual chambers. The modular design and custom LabVIEW™ control software provide flexibility and allow for expansion and modification to suit different experimental conditions. Superior accuracy is achieved when operating the instrument in a standalone configuration; however, measurements performed in conjunction with a previously developed multianalyte microphysiometer have shown low levels of crosstalk as well. Calibrations and experiments with primary and immortalized cell cultures demonstrate the performance of the instrument and its capabilities.
NASA Astrophysics Data System (ADS)
Andriani, Ade; Dewi, Izwita; Halomoan, Budi
2018-03-01
In general, this research is conducted to improve the quality of lectures on mathematics learning strategy in Mathematics Department. The specific objective of this research is to develop learning instrument of mathematics learning strategy based on Higher Order Thinking Skill (HOTS) that can be used to improve mathematical communication and self efficacy of mathematics education students. The type of research is development research (Research & Development), where this research aims to develop a new product or improve the product that has been made. This development research refers to the four-D Model, which consists of four stages: defining, designing, developing, and disseminating. The instrument of this research is the validation sheet and the student response sheet of the instrument.
Test results of the Chrysler upgraded automotive gas turbine engine: Initial design
NASA Technical Reports Server (NTRS)
Horvath, D.; Ribble, G. H., Jr.; Warren, E. L.; Wood, J. C.
1981-01-01
The upgraded engine as built to the original design was deficient in power and had excessive specific fuel consumption. A high instrumented version of the engine was tested to identify the sources of the engine problems. Analysis of the data shows the major problems to be low compressor and power turbine efficiency and excessive interstage duct losses. In addition, high HC and CO emission were measured at idle, and high NOx emissions at high energy speeds.
Barei, David P; Agel, Julie; Swiontkowski, Marc F
2007-01-01
The development of patient-oriented health status measurements has resulted in the emergence of several generic condition-specific and anatomic-specific instruments. These instruments are generally designed to measure the function of the individual as a whole from the individual's own point of view. They are not intended to replace traditional physician-oriented clinical outcome measures, such as complication rates, ranges of motion, or time to fracture union; instead, they are an attempt to measure the results of a treatment or condition from the patient's perspective. Over the past decade, the Musculoskeletal Function Assessment (MFA) instrument has been developed and used as one of the primary generic musculoskeletal functional assessment tools, in part because of its validity, reliability, and responsiveness. Despite the numerous publications reporting the MFA/SMFA, we are unaware of any publications that have used those results to subsequently affect patient care. We hope that this special interest article highlights the current underutilization of the available data and encourages the orthopedic community to maximize the clinical and research potential of the MFA/SMFA (Short Musculoskeletal Function Assessment).
Mathematics education graduate students' understanding of trigonometric ratios
NASA Astrophysics Data System (ADS)
Yiǧit Koyunkaya, Melike
2016-10-01
This study describes mathematics education graduate students' understanding of relationships between sine and cosine of two base angles in a right triangle. To explore students' understanding of these relationships, an elaboration of Skemp's views of instrumental and relational understanding using Tall and Vinner's concept image and concept definition was developed. Nine students volunteered to complete three paper and pencil tasks designed to elicit evidence of understanding and three students among these nine students volunteered for semi-structured interviews. As a result of fine-grained analysis of the students' responses to the tasks, the evidence of concept image and concept definition as well as instrumental and relational understanding of trigonometric ratios was found. The unit circle and a right triangle were identified as students' concept images, and the mnemonic was determined as their concept definition for trigonometry, specifically for trigonometric ratios. It is also suggested that students had instrumental understanding of trigonometric ratios while they were less flexible to act on trigonometric ratio tasks and had limited relational understanding. Additionally, the results indicate that graduate students' understanding of the concept of angle mediated their understanding of trigonometry, specifically trigonometric ratios.
Reliability analysis of instrument design of noninvasive bone marrow disease detector
NASA Astrophysics Data System (ADS)
Su, Yu; Li, Ting; Sun, Yunlong
2016-02-01
Bone marrow is an important hematopoietic organ, and bone marrow lesions (BMLs) may cause a variety of complications with high death rate and short survival time. Early detection and follow up care are particularly important. But the current diagnosis methods rely on bone marrow biopsy/puncture, with significant limitations such as invasion, complex operation, high risk, and discontinuous. It is highly in need of a non-invasive, safe, easily operated, and continuous monitoring technology. So we proposed to design a device aimed for detecting bone marrow lesions, which was based on near infrared spectrum technology. Then we fully tested its reliabilities, including the sensitivity, specificity, signal-to-noise ratio (SNR), stability, and etc. Here, we reported this sequence of reliability test experiments, the experimental results, and the following data analysis. This instrument was shown to be very sensitive, with distinguishable concentration less than 0.002 and with good linearity, stability and high SNR. Finally, these reliability-test data supported the promising clinical diagnosis and surgery guidance of our novel instrument in detection of BMLs.
THE VIRTUAL INSTRUMENT: SUPPORT FOR GRID-ENABLED MCELL SIMULATIONS
Casanova, Henri; Berman, Francine; Bartol, Thomas; Gokcay, Erhan; Sejnowski, Terry; Birnbaum, Adam; Dongarra, Jack; Miller, Michelle; Ellisman, Mark; Faerman, Marcio; Obertelli, Graziano; Wolski, Rich; Pomerantz, Stuart; Stiles, Joel
2010-01-01
Ensembles of widely distributed, heterogeneous resources, or Grids, have emerged as popular platforms for large-scale scientific applications. In this paper we present the Virtual Instrument project, which provides an integrated application execution environment that enables end-users to run and interact with running scientific simulations on Grids. This work is performed in the specific context of MCell, a computational biology application. While MCell provides the basis for running simulations, its capabilities are currently limited in terms of scale, ease-of-use, and interactivity. These limitations preclude usage scenarios that are critical for scientific advances. Our goal is to create a scientific “Virtual Instrument” from MCell by allowing its users to transparently access Grid resources while being able to steer running simulations. In this paper, we motivate the Virtual Instrument project and discuss a number of relevant issues and accomplishments in the area of Grid software development and application scheduling. We then describe our software design and report on the current implementation. We verify and evaluate our design via experiments with MCell on a real-world Grid testbed. PMID:20689618
Huy, Christina; Schneider, Sven
2008-06-01
Existing physical activity questionnaires have focused either on young and middle-aged adults or on the elderly. They have mainly assessed only a portion of possible physical activities or contained nation-specific sports. As there is no gold standard for a questionnaire-based assessment of physical activity in the over-50 population, recommendations for such a questionnaire relating to German-speaking countries were developed. This work included a systematic literature research, a survey of experts, and the design of a questionnaire based on validated measuring instruments. Finally, to test its reliability and application in the field, the complete questionnaire, including a retest, was applied by telephone interview (n = 57). The test-retest-correlation was r = 0.60 for the total time of physical activity and r = 0.52 for total energy expenditure. The researchers determined that the instrument is comprehensive in its coverage of all relevant domains of physical activity for the over-50 population; it is economically feasible and showed good acceptance.
Instrumental color control in textile printing
NASA Astrophysics Data System (ADS)
Connelly, Roland L., Sr.
1996-03-01
In textile printing there are several color outputs that need to be controlled. Just as important is the color coordination of these outputs. The types of color output are the video display on the textile design system (CATD for Computer Aided Textile Design), the color scanner, the color pattern printer, and the actual pattern printed on the textile substrate. Each of these systems has its own gamut(s) that is partially overlapping of the others and will require mapping and/or truncation to adequately represent the colors of the final print in the other systems. One of the goals of instrumentation systems is to control these devices so that the message of the pattern is the same on all four media. To accomplish this is a significant task that has yet to be completed to meet the rigorous requirements of the textile and apparel industries. Several of the major problems and directions for solving them will be discussed in this paper. These include getting good instrumental measurements, translation of data between systems, and specific problems related to the hard copy output.
Health Education in Elementary Schools. Curriculum Bulletin, 1969-70 Series. Number 2.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Bureau of Curriculum Development.
This publication serves as a basic instrument for health instruction in the elementary grades. It has been designed for adaptation in meeting the differing needs of New York City pupils. The format of the bulletin enables the teacher to plan specific lessons with health learning supplemented by recommended pupil activities through a basic set up…
TOPEX Software Document Series. Volume 5; Rev. 1; TOPEX GDR Processing
NASA Technical Reports Server (NTRS)
Lee, Jeffrey; Lockwood, Dennis; Hancock, David W., III
2003-01-01
This document is a compendium of the WFF TOPEX Software Development Team's knowledge regarding Geophysical Data Record (GDR) Processing. It includes many elements of a requirements document, a software specification document, a software design document, and a user's manual. In the more technical sections, this document assumes the reader is familiar with TOPEX and instrument files.
ERIC Educational Resources Information Center
Mokhtari, Kouider; Reichard, Carla
2004-01-01
This study investigated whether significant differences exist between first and second language readers in their metacognitive awareness and perceived use of specific strategies when reading for academic purposes in English. Three hundred and fifty college students (141 US and 209 Moroccan) completed an instrument designed to measure their…
75 FR 9548 - Reduction of Use of Social Security Numbers (SSN) in the Department of Defense (DoD)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-03
... authorization to receive specific categories of information. Computer network. The constituent element of an... elements reside on a computer. Form. A fixed arrangement of captioned spaces designed for entering and... activities of the Government or because of the information value of the data in them. Survey. An instrument...
Development and Validation of Instruments to Measure Learning of Expert-Like Thinking
ERIC Educational Resources Information Center
Adams, Wendy K.; Wieman, Carl E.
2011-01-01
This paper describes the process for creating and validating an assessment test that measures the effectiveness of instruction by probing how well that instruction causes students in a class to think like experts about specific areas of science. The design principles and process are laid out and it is shown how these align with professional…
Analytical Design of Terminally Guided Missiles.
1980-01-02
Equivalent Dominant Poles and Zeros Using Industrial Specifications," Trans. on Industrial Electronics and Control Instrumentation, Vol. IECI-26, No...The relaxation of the sampling period requirement and the flexibility of our new method facilitate the practical industrial implementation and...with the Guidance and Control Directorate, U.S. Army Missile Command, Redstone Arsenal, Alabama 35809. I. INTRODUCTION Most practical industrial circuits
The Inclusive Classroom Profile (ICP) Preliminary Findings of Demonstration Study in North Carolina
ERIC Educational Resources Information Center
Soukakou, E.; Winton, P.; West, T.
2012-01-01
The Inclusive Classroom Profile (ICP) was developed in response to a lack of validated instruments designed specifically to measure the quality of inclusive practices, and it is based on research evidence on the effectiveness of specialized instructional strategies for meeting the individual needs of children in inclusive settings (Odom, 2004;…
The Work-Related Quality of Life Scale for Higher Education Employees
ERIC Educational Resources Information Center
Edwards, Julian A.; Van Laar, Darren; Easton, Simon; Kinman, Gail
2009-01-01
Previous research suggests that higher education employees experience comparatively high levels of job stress. A range of instruments, both generic and job-specific, has been used to measure stressors and strains in this occupational context. The Work-related Quality of Life (WRQoL) scale is a measure designed to capture perceptions of the working…
Actively Controlled Magnetic Vibration-Isolation System
NASA Technical Reports Server (NTRS)
Grodsinky, Carlos M.; Logsdon, Kirk A.; Wbomski, Joseph F.; Brown, Gerald V.
1993-01-01
Prototype magnetic suspension system with active control isolates object from vibrations in all six degrees of freedom at frequencies as low as 0.01 Hz. Designed specifically to protect instruments aboard spacecraft by suppressing vibrations to microgravity levels; basic control approach used for such terrestrial uses as suppression of shocks and other vibrations in trucks and railroad cars.
IMPROVED SPECTROPHOTOMETER FIBER SAMPLING SYSTEM FOR COTTON FIBER COLOR MEASUREMENTS
USDA-ARS?s Scientific Manuscript database
Cotton in the U.S. is classified for color using the Uster® High Volume Instrument (HVI), and the parameters Rd and +b are used to designate color grades for cotton fiber. However, Rd and +b are cotton-specific color parameters, and the need existed to demonstrate the relationships of Rd and +b to...
Linking CALL and SLA: Using the IRIS Database to Locate Research Instruments
ERIC Educational Resources Information Center
Handley, Zöe; Marsden, Emma
2014-01-01
To establish an evidence base for future computer-assisted language learning (CALL) design, CALL research needs to move away from CALL versus non-CALL comparisons, and focus on investigating the differential impact of individual coding elements, that is, specific features of a technology which might have an impact on learning (Pederson, 1987).…
Mechanism Design Principle for Optical-Precision, Deployable Instruments
NASA Technical Reports Server (NTRS)
Lake, Mark S.; Hachkowski, M. Roman
2000-01-01
The present paper is intended to be a guide for the design of 'microdynamically quiet' deployment mechanisms for optical-precision structures, such as deployable telescope mirrors and optical benches. Many of the guidelines included herein come directly from the field of optomechanical engineering, and are neither newly developed guidelines nor are they uniquely applicable to high-precision deployment mechanisms. However, the application of these guidelines to the design of deployment mechanisms is a rather new practice, so efforts are made herein to illustrate the process through the discussion of specific examples. The present paper summarizes a more extensive set of design guidelines for optical-precision mechanisms that are under development.
A mechanical rotator for neutron scattering measurements
Thaler, A.; Northen, E.; Aczel, A. A.; ...
2016-12-01
We have designed and built a mechanical rotation system for use in single crystal neutron scattering experiments at low temperatures. The main motivation for this device is to facilitate the application of magnetic fields transverse to a primary training axis, using only a vertical cryomagnet. Development was done in the context of a triple-axis neutron spectrometer, but the design is such that it can be generalized to a number of different instruments or measurement techniques. Here, we discuss some of the experimental constraints motivating the design, followed by design specifics, preliminary experimental results, and a discussion of potential uses andmore » future extension possibilities.« less
Design and simulation of a semiconductor chip-based visible - NIR spectrometer for Earth observation
NASA Astrophysics Data System (ADS)
Coote, J.; Woolliams, E.; Fox, N.; Goodyer, I. D.; Sweeney, S. J.
2014-03-01
We present the development of a novel semiconductor chip-based spectrometer for calibration of Earth observation instruments. The chip follows the Solo spectroscopy approach utilising an array of microdisk resonators evanescently coupled to a central waveguide. Each resonator is tuned to select out a specific wavelength from the incoming spectrum, and forms a p-i-n junction in which current is generated when light of the correct wavelength is present. In this paper we discuss important design aspects including the choice of semiconductor material, design of semiconductor quantum well structures for optical absorption, and design and optimisation of the waveguide and resonators.
Design and fabrication of self-assembled thin films
NASA Astrophysics Data System (ADS)
Topasna, Daniela M.; Topasna, Gregory A.
2015-10-01
Students experience the entire process of designing, fabricating and testing thin films during their capstone course. The films are fabricated by the ionic-self assembled monolayer (ISAM) technique, which is suited to a short class and is relatively rapid, inexpensive and environmentally friendly. The materials used are polymers, nanoparticles, and small organic molecules that, in various combinations, can create films with nanometer thickness and with specific properties. These films have various potential applications such as pH optical sensors or antibacterial coatings. This type of project offers students an opportunity to go beyond the standard lecture and labs and to experience firsthand the design and fabrication processes. They learn new techniques and procedures, as well as familiarize themselves with new instruments and optical equipment. For example, students learn how to characterize the films by using UV-Vis-NIR spectrophotometry and in the process learn how the instruments operate. This work compliments a previous exercise that we introduced where students use MATHCAD to numerically model the transmission and reflection of light from thin films.
Study of application of space telescope science operations software for SIRTF use
NASA Technical Reports Server (NTRS)
Dignam, F.; Stetson, E.; Allendoerfer, W.
1985-01-01
The design and development of the Space Telescope Science Operations Ground System (ST SOGS) was evaluated to compile a history of lessons learned that would benefit NASA's Space Infrared Telescope Facility (SIRTF). Forty-nine specific recommendations resulted and were categorized as follows: (1) requirements: a discussion of the content, timeliness and proper allocation of the system and segment requirements and the resulting impact on SOGS development; (2) science instruments: a consideration of the impact of the Science Instrument design and data streams on SOGS software; and (3) contract phasing: an analysis of the impact of beginning the various ST program segments at different times. Approximately half of the software design and source code might be useable for SIRTF. Transportability of this software requires, at minimum, a compatible DEC VAX-based architecture and VMS operating system, system support software similar to that developed for SOGS, and continued evolution of the SIRTF operations concept and requirements such that they remain compatible with ST SOGS operation.
Muratov, Sergei; Podbielski, Dominik W; Jack, Susan M; Ahmed, Iqbal Ike K; Mitchell, Levine A H; Baltaziak, Monika; Xie, Feng
2016-11-08
A primary objective of healthcare services is to improve patients' health and health-related quality of life (HRQoL). Glaucoma, which affects a substantial proportion of the world population, has a significant detrimental impact on HRQoL. Although there are a number of glaucoma-specific questionnaires to measure HRQoL, none is preference-based which prevent them from being used in health economic evaluation. The proposed study is aimed to develop a preference-based instrument that is capable of capturing important effects specific to glaucoma and treatments on HRQoL and is scored based on the patients' preferences. A sequential, exploratory mixed methods design will be used to guide the development and evaluation of the HRQoL instrument. The study consists of several stages to be implemented sequentially: item identification, item selection, validation and valuation. The instrument items will be identified and selected through a literature review and the conduct of a qualitative study. Validation will be conducted to establish psychometric properties of the instrument followed by a valuation exercise to derive utility scores for the health states described. This study has been approved by the Trillium Health Partners Research Ethics Board (ID number 753). All personal information will be de-identified with the identification code kept in a secured location including the rest of the study data. Only qualified and study-related personnel will be allowed to access the data. The results of the study will be distributed widely through peer-reviewed journals, conferences and internal meetings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes
NASA Technical Reports Server (NTRS)
Cataldo, Giuseppe; Hsieh, Wen-Ting; Huang, Wei-Chung; Moseley, S. Harvey; Stevenson, Thomas R.; Wollack, Edward J.
2014-01-01
The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (µ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.
NASA Technical Reports Server (NTRS)
Cataldo, Giuseppe
2014-01-01
The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.
Micro-Spec: an integrated direct-detection spectrometer for far-infrared space telescopes
NASA Astrophysics Data System (ADS)
Cataldo, Giuseppe; Hseih, Wen-Ting; Huang, Wei-Chung; Moseley, S. H.; Stevenson, Thomas R.; Wollack, Edward J.
2014-08-01
The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 μm wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a ~10 cm2 silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for μ-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. Two point designs with resolving power of 260 and 520 and an RMS phase error less than ~0:004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.
NASA Technical Reports Server (NTRS)
Bleacher, L. V.; Lakew, B.; Bracken, J.; Brown, T.; Rivera, R.
2017-01-01
The NASA Goddard Planetary Science Winter School (PSWS) is a Goddard Space Flight Center-sponsored training program, managed by Goddard's Solar System Exploration Division (SSED), for Goddard-based postdoctoral fellows and early career planetary scientists. Currently in its third year, the PSWS is an experiential training program for scientists interested in participating on future planetary science instrument teams. Inspired by the NASA Planetary Science Summer School, Goddard's PSWS is unique in that participants learn the flight instrument lifecycle by designing a planetary flight instrument under actual consideration by Goddard for proposal and development. They work alongside the instrument Principal Investigator (PI) and engineers in Goddard's Instrument Design Laboratory (IDL; idc.nasa.gov), to develop a science traceability matrix and design the instrument, culminating in a conceptual design and presentation to the PI, the IDL team and Goddard management. By shadowing and working alongside IDL discipline engineers, participants experience firsthand the science and cost constraints, trade-offs, and teamwork that are required for optimal instrument design. Each PSWS is collaboratively designed with representatives from SSED, IDL, and the instrument PI, to ensure value added for all stakeholders. The pilot PSWS was held in early 2015, with a second implementation in early 2016. Feedback from past participants was used to design the 2017 PSWS, which is underway as of the writing of this abstract.
NASA Astrophysics Data System (ADS)
Kawka, O. E.; Nelson, J. S.; Manalang, D.; Kelley, D. S.
2016-02-01
The Cabled Array component of the NSF-funded Ocean Observatories Initiative (OOI) provides access to real-time physical, chemical, geological, and biological data from water column and seafloor platforms/instruments at sites spanning the southern half of the Juan de Fuca Plate. The Quality Assurance (QA) program for OOI data is designed to ensure that data products meet OOI science requirements. This overall data QA plan establishes the guidelines for assuring OOI data quality and summarizes Quality Control (QC) protocols and procedures, based on best practices, which can be utilized to ensure the highest quality data across the OOI program. This presentation will highlight, specifically, the QA/QC approach being utilized for the OOI Cabled Array infrastructure and data and will include a summary of both shipboard and shore-based protocols currently in use. Aspects addressed will be pre-deployment instrument testing and calibration checks, post-deployment and pre-recovery field verification of data, and post-recovery "as-found" testing of instruments. Examples of QA/QC data will be presented and specific cases of cabled data will be discussed in the context of quality assessments and adjustment/correction of OOI datasets overall for inherent sensor drift and/or instrument fouling.
The LAMP instrument at the Linac Coherent Light Source free-electron laser
Osipov, Timur; Bostedt, Christoph; Castagna, J. -C.; ...
2018-03-23
The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusivemore » metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here in this paper we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.« less
The LAMP instrument at the Linac Coherent Light Source free-electron laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osipov, Timur; Bostedt, Christoph; Castagna, J. -C.
The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusivemore » metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here in this paper we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.« less
Very high stability systems: LMJ target alignment system and MTG imager test setup
NASA Astrophysics Data System (ADS)
Compain, Eric; Maquet, Philippe; Kunc, Thierry; Marque, Julien; Lauer-Solelhac, Maxime; Delage, Laurent; Lanternier, Catherine
2015-09-01
Most of space instruments and research facilities require test equipment with demanding opto-mechanical stability. In some specific cases, when the stability performance directly drives the final performance of the scientific mission and when feasibility is questionable, specific methods must be implemented for the associated technical risk management. In present paper, we will present our heritage in terms of methodology, design, test and the associated results for two specific systems : the SOPAC-POS and the MOTA, generating new references for future developments. From a performance point of view, we will emphasis on following key parameters : design symmetry, thermal load management, and material and structural choices. From a method point of view the difficulties arise first during design, from the strong coupling between the thermal, mechanical and optical performance models, and then during testing, from the difficulty of conceiving test setup having appropriate performance level. We will present how these limitations have been overcome. SOPAC-POS is the target alignment system of the LMJ, Laser Mega Joule, the French inertial confinement fusion research center. Its stability has been demonstrated by tests in 2014 after 10 years of research and development activities, achieving 1μm stability @ 6m during one hour periods. MOTA is an Optical Ground Support Equipment aiming at qualifying by tests the Flexible Combined Imager (FCI). FCI is an instrument for the meteorological satellite MTG-I, a program of and funded by the European Space Agency and under prime contractorship of Thales Alenia Space. Optimized design will allow to get better than 0.2 μrad stability for one hour periods, as required for MTF measurement.
Design and validation of instruments to measure knowledge.
Elliott, T E; Regal, R R; Elliott, B A; Renier, C M
2001-01-01
Measuring health care providers' learning after they have participated in educational interventions that use experimental designs requires valid, reliable, and practical instruments. A literature review was conducted. In addition, experience gained from designing and validating instruments for measuring the effect of an educational intervention informed this process. The eight main steps for designing, validating, and testing the reliability of instruments for measuring learning outcomes are presented. The key considerations and rationale for this process are discussed. Methods for critiquing and adapting existent instruments and creating new ones are offered. This study may help other investigators in developing valid, reliable, and practical instruments for measuring the outcomes of educational activities.
Multi-Mission Automated Task Invocation Subsystem
NASA Technical Reports Server (NTRS)
Cheng, Cecilia S.; Patel, Rajesh R.; Sayfi, Elias M.; Lee, Hyun H.
2009-01-01
Multi-Mission Automated Task Invocation Subsystem (MATIS) is software that establishes a distributed data-processing framework for automated generation of instrument data products from a spacecraft mission. Each mission may set up a set of MATIS servers for processing its data products. MATIS embodies lessons learned in experience with prior instrument- data-product-generation software. MATIS is an event-driven workflow manager that interprets project-specific, user-defined rules for managing processes. It executes programs in response to specific events under specific conditions according to the rules. Because requirements of different missions are too diverse to be satisfied by one program, MATIS accommodates plug-in programs. MATIS is flexible in that users can control such processing parameters as how many pipelines to run and on which computing machines to run them. MATIS has a fail-safe capability. At each step, MATIS captures and retains pertinent information needed to complete the step and start the next step. In the event of a restart, this information is retrieved so that processing can be resumed appropriately. At this writing, it is planned to develop a graphical user interface (GUI) for monitoring and controlling a product generation engine in MATIS. The GUI would enable users to schedule multiple processes and manage the data products produced in the processes. Although MATIS was initially designed for instrument data product generation,
Report on the formal specification and partial verification of the VIPER microprocessor
NASA Technical Reports Server (NTRS)
Brock, Bishop; Hunt, Warren A., Jr.
1991-01-01
The formal specification and partial verification of the VIPER microprocessor is reviewed. The VIPER microprocessor was designed by RSRE, Malvern, England, for safety critical computing applications (e.g., aircraft, reactor control, medical instruments, armaments). The VIPER was carefully specified and partially verified in an attempt to provide a microprocessor with completely predictable operating characteristics. The specification of VIPER is divided into several levels of abstraction, from a gate-level description up to an instruction execution model. Although the consistency between certain levels was demonstrated with mechanically-assisted mathematical proof, the formal verification of VIPER was never completed.
User interfaces in space science instrumentation
NASA Astrophysics Data System (ADS)
McCalden, Alec John
This thesis examines user interaction with instrumentation in the specific context of space science. It gathers together existing practice in machine interfaces with a look at potential future usage and recommends a new approach to space science projects with the intention of maximising their science return. It first takes a historical perspective on user interfaces and ways of defining and measuring the science return of a space instrument. Choices of research methodology are considered. Implementation details such as the concepts of usability, mental models, affordance and presentation of information are described, and examples of existing interfaces in space science are given. A set of parameters for use in analysing and synthesizing a user interface is derived by using a set of case studies of diverse failures and from previous work. A general space science user analysis is made by looking at typical practice, and an interview plus persona technique is used to group users with interface designs. An examination is made of designs in the field of astronomical instrumentation interfaces, showing the evolution of current concepts and including ideas capable of sustaining progress in the future. The parameters developed earlier are then tested against several established interfaces in the space science context to give a degree of confidence in their use. The concept of a simulator that is used to guide the development of an instrument over the whole lifecycle is described, and the idea is proposed that better instrumentation would result from more efficient use of the resources available. The previous ideas in this thesis are then brought together to describe a proposed new approach to a typical development programme, with an emphasis on user interaction. The conclusion shows that there is significant room for improvement in the science return from space instrumentation by attention to the user interface.
CARVE-FTS observations of arctic CO2, CH4, and CO: overview of the instrument
NASA Astrophysics Data System (ADS)
Dupont, Fabien; Tanguay, François; Li, Manyuan; Perron, Gaetan; Miller, Charles E.; Dinardo, Steven J.; Kurosu, Thomas P.
2012-09-01
CARVE-FTS is a near-IR Fourier-Transform Spectrometer (FTS) used by the Jet Propulsion Laboratory (JPL) for the Carbon in Arctic Reservoirs Vulnerability Experiment (CARVE). CARVE is a 5-year mission of intensive aircraft campaigns in the Alaskan Arctic selected as part of NASA's Earth Ventures program (EV-1). The CARVE-FTS has been designed, manufactured and tested by ABB Inc. The objective of this instrument is to provide integrated column measurements of carbon dioxide (CO2), methane (CH4), and carbon monoxide (CO). The system is inspired from the TSUKUBA-FTS built by ABB for the Japanese Aerospace Exploration Agency (JAXA). JAXA uses the instrument for preparation, calibration and validation within the GOSAT program. The instrument is a Michelson based FTS with three spectral bands. The light modulator is a Michelson single pass type interferometer with large aperture and medium spectral resolution. It provides infrared spectra from 12,900 cm-1 to 13,200 cm-1, from 5,800 cm-1 to 6,400 cm-1, and from 4,200 cm-1 to 4,900 cm-1. This instrument is also able to measure the scene radiance with S and P polarization simultaneously using monopixel detectors. The instrument is mounted on a damping platform and is installed in an aircraft. It delivers continuous data for flight campaigns over the Alaskan Arctic. SNR higher than 100 is reached for each band and the measured ILS full width at half maximum is as low as 0.26 cm-1 at 6,566 cm-1. We present the instrument design, its specification and test results obtained at ABB.
Buchholz, Bernhard; Kallweit, Sören; Ebert, Volker
2016-12-30
Instrument operation in harsh environments often significantly impacts the trust level of measurement data. While commercial instrument manufacturers clearly define the deployment conditions to achieve trustworthy data in typical standard applications, it is frequently unavoidable in scientific field applications to operate instruments outside these commercial standard application specifications. Scientific instrumentation, however, is employing cutting-edge technology and often highly optimized but also lacks long-term field tests to assess the field vs. laboratory performance. Recently, we developed the Selective Extractive Laser Diode Hygrometer (SEALDH-II), which addresses field and especially airborne applications as well as metrological laboratory validations. SEALDH-II targets reducing deviations between airborne hygrometers (currently up to 20% between the most advanced hygrometers) with a new holistic, internal control and validation concept, which guarantees the transfer of the laboratory performance into a field scenario by capturing more than 80 instrument internal "housekeeping" data to nearly perfectly control SEALDH-II's health status. SEALDH-II uses a calibration-free, first principles based, direct Tuneable Diode Laser Absorption Spectroscopy (dTDLAS) approach, to cover the entire atmospheric humidity measurement range from about 3 to 40,000 ppmv with a calculated maximum uncertainty of 4.3% ± 3 ppmv. This is achieved not only by innovations in internal instrument monitoring and design, but also by active control algorithms such as a high resolution spectral stabilization. This paper describes the setup, working principles, and instrument stabilization, as well as its precision validation and long-term stress tests in an environmental chamber over an environmental temperature and humidity range of ΔT = 50 K and ΔRH = 80% RH, respectively.
Greeff, Minrie; Chepuka, Lignet M; Chilemba, Winnie; Chimwaza, Angela F; Kululanga, Lucy I; Kgositau, Mabedi; Manyedi, Eva; Shaibu, Sheila; Wright, Susan C D
2014-01-01
The relationship between quality of life (QoL) and antiretroviral treatment (ART) has mainly been studied using quantitative scales often not appropriate for use in other contexts and without taking peoples' lived experiences into consideration. Sub-Saharan Africa has the highest incidence of HIV and AIDS yet there is paucity in research done on QoL. This research report is intended to give an account of the use of a mixed method convergent parallel design as a novice approach to evaluate an instrument's context specificity, appropriateness and usefulness in another context for which it was designed. Data were collected through a qualitative exploration of the experiences of QoL of people living with HIV or AIDS (PLHA) in Africa since being on ART, as well as the quantitative measurements obtained from the HIV/AIDS-targeted quality of life (HAT-QoL) instrument. This study was conducted in three African countries. Permission and ethical approval to conduct the study were obtained. Purposive voluntary sampling was used to recruit PLHA through mediators working in community-based HIV/AIDS organisations and health clinics. Interviews were analysed through open coding and the quantitative data through descriptive statistics and the Cronbach's alpha coefficient. A much wider range and richness of experiences were expressed than measured by the HAT-QoL instrument. Although an effective instrument for use in the USA, it was found not to be sensitive, appropriate and useful in an African context in its present form. The recommendations focus on adapting the instrument using the data from the in-depth interviews or to develop a context-sensitive instrument that could measure QoL of PLHA in Africa.
Guidance, navigation, and control subsystem for the EOS-AM spacecraft
NASA Technical Reports Server (NTRS)
Linder, David M.; Tolek, Joseph T.; Lombardo, John
1992-01-01
This paper presents the preliminary design of the Guidance, Navigation, and Control (GN&C) subsystem for the EOS-AM spacecraft and specifically focuses on the GN&C Normal Mode design. First, a brief description of the EOS-AM science mission, instruments, and system-level spacecraft design is provided. Next, an overview of the GN&C subsystem functional and performance requirements, hardware, and operating modes is presented. Then, the GN&C Normal Mode attitude determination, attitude control, and navigation systems are detailed. Finally, descriptions of the spacecraft's overall jitter performance and Safe Mode are provided.
A finite element investigation of upper cervical instrumentation.
Puttlitz, C M; Goel, V K; Traynelis, V C; Clark, C R
2001-11-15
The finite element technique was used to predict changes in biomechanics that accompany the application of a novel instrumentation system designed for use in the upper cervical spine. To determine alterations in joint loading, kinematics, and instrumentation stresses in the craniovertebral junction after application of a novel instrumentation system. Specifically, this design was used to assess the changes in these parameters brought about by two different cervical anchor types: C2 pedicle versus C2-C1 transarticular screws, and unilateral versus bilateral instrumentation. Arthrodesis procedures can be difficult to obtain in the highly mobile craniovertebral junction. Solid fusion is most likely achieved when motion is eliminated. Biomechanical studies have shown that C1-C2 transarticular screws provide good stability in craniovertebral constructs; however, implantation of these screws is accompanied by risk of vertebral artery injury. A novel instrumentation system that can be used with transarticular screws or with C2 pedicle screws has been developed. This design also allows for unilateral or bilateral implantation. However, the authors are unaware of any reports to date on the changes in joint loading or instrumentation stresses that are associated with the choice of C2 anchor or unilateral/bilateral use. A ligamentous, nonlinear, sliding contact, three-dimensional finite element model of the C0-C1-C2 complex and a novel instrumentation system was developed. Validation of the model has been previously reported. Finite element models representing combinations of cervical anchor type (C1-C2 transarticular screws vs. C2 pedicle screws) and unilateral versus bilateral instrumentation were evaluated. All models were subjected to compression with pure moments in either flexion, extension, or lateral bending. Kinematic reductions with respect to the intact (uninjured and without instrumentation) case caused by instrumentation use were reported. Changes in loading profiles through the right and left C0-C1 and C1-C2 facets, transverse ligament-dens, and dens-anterior ring of C1 articulations were calculated by the finite element model. Maximum von Mises stresses within the instrumentation were predicted for each model variant and loading scenario. Bilateral instrumentation provided greater motion reductions than the unilateral instrumentation. When used bilaterally, C2 pedicle screws approximate the kinematic reductions and instrumentation stresses (except in lateral bending) that are seen with C1-C2 transarticular screws. The finite element model predicted that the maximum stress was always in the region in which the plate transformed into the rod. To the best of the authors' knowledge, this is the first report of predicting changes in loading in the upper cervical spine caused by instrumentation. The most significant conclusion that can be drawn from the finite element model predictions is that C2 pedicle screw fixation provides the same relative stability and instrumentation stresses as C1-C2 transarticular screw use. C2 pedicle screws can be a good alternative to C2-C1 transarticular screws when bilateral instrumentation is applied.
Cook, David A; Reed, Darcy A
2015-08-01
The Medical Education Research Study Quality Instrument (MERSQI) and the Newcastle-Ottawa Scale-Education (NOS-E) were developed to appraise methodological quality in medical education research. The study objective was to evaluate the interrater reliability, normative scores, and between-instrument correlation for these two instruments. In 2014, the authors searched PubMed and Google for articles using the MERSQI or NOS-E. They obtained or extracted data for interrater reliability-using the intraclass correlation coefficient (ICC)-and normative scores. They calculated between-scale correlation using Spearman rho. Each instrument contains items concerning sampling, controlling for confounders, and integrity of outcomes. Interrater reliability for overall scores ranged from 0.68 to 0.95. Interrater reliability was "substantial" or better (ICC > 0.60) for nearly all domain-specific items on both instruments. Most instances of low interrater reliability were associated with restriction of range, and raw agreement was usually good. Across 26 studies evaluating published research, the median overall MERSQI score was 11.3 (range 8.9-15.1, of possible 18). Across six studies, the median overall NOS-E score was 3.22 (range 2.08-3.82, of possible 6). Overall MERSQI and NOS-E scores correlated reasonably well (rho 0.49-0.72). The MERSQI and NOS-E are useful, reliable, complementary tools for appraising methodological quality of medical education research. Interpretation and use of their scores should focus on item-specific codes rather than overall scores. Normative scores should be used for relative rather than absolute judgments because different research questions require different study designs.
Chandramohan, Daniel; Clark, Samuel J.; Jakob, Robert; Leitao, Jordana; Rao, Chalapati; Riley, Ian; Setel, Philip W.
2018-01-01
Background Verbal autopsy (VA) is a practical method for determining probable causes of death at the population level in places where systems for medical certification of cause of death are weak. VA methods suitable for use in routine settings, such as civil registration and vital statistics (CRVS) systems, have developed rapidly in the last decade. These developments have been part of a growing global momentum to strengthen CRVS systems in low-income countries. With this momentum have come pressure for continued research and development of VA methods and the need for a single standard VA instrument on which multiple automated diagnostic methods can be developed. Methods and findings In 2016, partners harmonized a WHO VA standard instrument that fully incorporates the indicators necessary to run currently available automated diagnostic algorithms. The WHO 2016 VA instrument, together with validated approaches to analyzing VA data, offers countries solutions to improving information about patterns of cause-specific mortality. This VA instrument offers the opportunity to harmonize the automated diagnostic algorithms in the future. Conclusions Despite all improvements in design and technology, VA is only recommended where medical certification of cause of death is not possible. The method can nevertheless provide sufficient information to guide public health priorities in communities in which physician certification of deaths is largely unavailable. The WHO 2016 VA instrument, together with validated approaches to analyzing VA data, offers countries solutions to improving information about patterns of cause-specific mortality. PMID:29320495
Miniature near-infrared spectrometer for point-of-use chemical analysis
NASA Astrophysics Data System (ADS)
Friedrich, Donald M.; Hulse, Charles A.; von Gunten, Marc; Williamson, Eric P.; Pederson, Christopher G.; O'Brien, Nada A.
2014-03-01
Point-of-use chemical analysis holds tremendous promise for a number of industries, including agriculture, recycling, pharmaceuticals and homeland security. Near infrared (NIR) spectroscopy is an excellent candidate for these applications, with minimal sample preparation for real-time decision-making. We will detail the development of a golf ball-sized NIR spectrometer developed specifically for this purpose. The instrument is based upon a thin-film dispersive element that is very stable over time and temperature, with less than 2 nm change expected over the operating temperature range and lifetime of the instrument. This filter is coupled with an uncooled InGaAs detector array in a small, rugged, environmentally stable optical bench ideally suited to unpredictable environments. The resulting instrument weighs less than 60 grams, includes onboard illumination and collection optics for diffuse reflectance applications in the 900-1700 nm wavelength range, and is USB-powered. It can be driven in the field by a laptop, tablet or even a smartphone. The software design includes the potential for both on-board and cloud-based storage, analysis and decision-making. The key attributes of the instrument and the underlying design tradeoffs will be discussed, focusing on miniaturization, ruggedization, power consumption and cost. The optical performance of the instrument, as well as its fit-for purpose will be detailed. Finally, we will show that our manufacturing process has enabled us to build instruments with excellent unit-to-unit reproducibility. We will show that this is a key enabler for instrumentindependent chemical analysis models, a requirement for mass point-of-use deployment.
Optical turbulence profiling with Stereo-SCIDAR for VLT and ELT
NASA Astrophysics Data System (ADS)
Osborn, J.; Wilson, R. W.; Sarazin, M.; Butterley, T.; Chacón, A.; Derie, F.; Farley, O. J. D.; Haubois, X.; Laidlaw, D.; LeLouarn, M.; Masciadri, E.; Milli, J.; Navarrete, J.; Townson, M. J.
2018-04-01
Knowledge of the Earth's atmospheric optical turbulence is critical for astronomical instrumentation. Not only does it enable performance verification and optimisation of existing systems but it is required for the design of future instruments. As a minimum this includes integrated astro-atmospheric parameters such as seeing, coherence time and isoplanatic angle, but for more sophisticated systems such as wide field adaptive optics enabled instrumentation the vertical structure of the turbulence is also required. Stereo-SCIDAR is a technique specifically designed to characterise the Earth's atmospheric turbulence with high altitude resolution and high sensitivity. Together with ESO, Durham University has commissioned a Stereo-SCIDAR instrument at Cerro Paranal, Chile, the site of the Very Large Telescope (VLT), and only 20 km from the site of the future Extremely Large Telescope (ELT). Here we provide results from the first 18 months of operation at ESO Paranal including instrument comparisons and atmospheric statistics. Based on a sample of 83 nights spread over 22 months covering all seasons, we find the median seeing to be 0.64" with 50% of the turbulence confined to an altitude below 2 km and 40% below 600 m. The median coherence time and isoplanatic angle are found as 4.18 ms and 1.75" respectively. A substantial campaign of inter-instrument comparison was also undertaken to assure the validity of the data. The Stereo-SCIDAR profiles (optical turbulence strength and velocity as a function of altitude) have been compared with the Surface-Layer SLODAR, MASS-DIMM and the ECMWF weather forecast model. The correlation coefficients are between 0.61 (isoplanatic angle) and 0.84 (seeing).
Vita, Fabio; Kern, Christoph; Inguaggiato, Salvatore
2014-01-01
Active long-path differential optical absorption spectroscopy (LP-DOAS) has been an effective tool for measuring atmospheric trace gases for several decades. However, instruments were large, heavy and power-inefficient, making their application to remote environments extremely challenging. Recent developments in fibre-coupling telescope technology and the availability of ultraviolet light emitting diodes (UV-LEDS) have now allowed us to design and construct a lightweight, portable, low-power LP-DOAS instrument for use at remote locations and specifically for measuring degassing from active volcanic systems. The LP-DOAS was used to measure sulfur dioxide (SO2) emissions from La Fossa crater, Vulcano, Italy, where column densities of up to 1.2 × 1018 molec cm−2 (~ 500 ppmm) were detected along open paths of up to 400 m in total length. The instrument's SO2 detection limit was determined to be 2 × 1016 molec cm−2 (~ 8 ppmm), thereby making quantitative detection of even trace amounts of SO2 possible. The instrument is capable of measuring other volcanic volatile species as well. Though the spectral evaluation of the recorded data showed that chlorine monoxide (ClO) and carbon disulfide (CS2) were both below the instrument's detection limits during the experiment, the upper limits for the X / SO2 ratio (X = ClO, CS2) could be derived, and yielded 2 × 10−3 and 0.1, respectively. The robust design and versatility of the instrument make it a promising tool for monitoring of volcanic degassing and understanding processes in a range of volcanic systems.
Design, Fabrication and Evaluation of Prototype Wayside Brake Inspection Sensors
DOT National Transportation Integrated Search
1980-06-01
Prototype Wayside instrumentation has been designed, developed, and tested that proves the feasibility of measuring braking system effectiveness on moving rail cars. The instrumentation system includes a specially designed short section of instrument...
High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking
NASA Astrophysics Data System (ADS)
Liss, J.; Dunagan, S. E.; Johnson, R. R.; Chang, C. S.; LeBlanc, S. E.; Shinozuka, Y.; Redemann, J.; Flynn, C. J.; Segal-Rosenhaimer, M.; Pistone, K.; Kacenelenbogen, M. S.; Fahey, L.
2016-12-01
High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera TrackingThe NASA Ames Sun-photometer-Satellite Group, DOE, PNNL Atmospheric Sciences and Global Change Division, and NASA Goddard's AERONET (AErosol RObotic NETwork) team recently collaborated on the development of a new airborne sunphotometry instrument that provides information on gases and aerosols extending far beyond what can be derived from discrete-channel direct-beam measurements, while preserving or enhancing many of the desirable AATS features (e.g., compactness, versatility, automation, reliability). The enhanced instrument combines the sun-tracking ability of the current 14-Channel NASA Ames AATS-14 with the sky-scanning ability of the ground-based AERONET Sun/sky photometers, while extending both AATS-14 and AERONET capabilities by providing full spectral information from the UV (350 nm) to the SWIR (1,700 nm). Strengths of this measurement approach include many more wavelengths (isolated from gas absorption features) that may be used to characterize aerosols and detailed (oversampled) measurements of the absorption features of specific gas constituents. The Sky Scanning Sun Tracking Airborne Radiometer (3STAR) replicates the radiometer functionality of the AATS-14 instrument but incorporates modern COTS technologies for all instruments subsystems. A 19-channel radiometer bundle design is borrowed from a commercial water column radiance instrument manufactured by Biospherical Instruments of San Diego California (ref, Morrow and Hooker)) and developed using NASA funds under the Small Business Innovative Research (SBIR) program. The 3STAR design also incorporates the latest in robotic motor technology embodied in Rotary actuators from Oriental motor Corp. having better than 15 arc seconds of positioning accuracy. Control system was designed, tested and simulated using a Hybrid-Dynamical modeling methodology. The design also replaces the classic quadrant detector tracking sensor with a wide dynamic range camera that provides a high precision solar position tracking signal as well as an image of the sky in the 45° field of view around the solar axis, which can be of great assistance in flagging data for cloud effects or other factors that might impact data quality.
Water NSTF Design, Instrumentation, and Test Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lisowski, Darius D.; Gerardi, Craig D.; Hu, Rui
The following report serves as a formal introduction to the water-based Natural convection Shutdown heat removal Test Facility (NSTF) program at Argonne. Since 2005, this US Department of Energy (DOE) sponsored program has conducted large scale experimental testing to generate high-quality and traceable validation data for guiding design decisions of the Reactor Cavity Cooling System (RCCS) concept for advanced reactor designs. The most recent facility iteration, and focus of this report, is the operation of a 1/2 scale model of a water-RCCS concept. Several features of the NSTF prototype align with the conceptual design that has been publicly released formore » the AREVA 625 MWt SC-HTGR. The design of the NSTF also retains all aspects common to a fundamental boiling water thermosiphon, and thus is well poised to provide necessary experimental data to advance basic understanding of natural circulation phenomena and contribute to computer code validation. Overall, the NSTF program operates to support the DOE vision of aiding US vendors in design choices of future reactor concepts, advancing the maturity of codes for licensing, and ultimately developing safe and reliable reactor technologies. In this report, the top-level program objectives, testing requirements, and unique considerations for the water cooled test assembly are discussed, and presented in sufficient depth to support defining the program’s overall scope and purpose. A discussion of the proposed 6-year testing program is then introduced, which outlines the specific strategy and testing plan for facility operations. The proposed testing plan has been developed to meet the toplevel objective of conducting high-quality test operations that span across a broad range of single- and two-phase operating conditions. Details of characterization, baseline test cases, accident scenario, and parametric variations are provided, including discussions of later-stage test cases that examine the influence of geometric variations and off-normal configurations. The facility design follows, including as-built dimensions and specifications of the various mechanical and liquid systems, design choices for the test section, water storage tank, and network piping. Specifications of the instrumentation suite are then presented, along with specific information on performance windows, measurement uncertainties, and installation locations. Finally, descriptions of the control systems and heat removal networks are provided, which have been engineered to support precise quantification of energy balances and facilitate well-controlled test operations.« less
Mariner Jupiter/Saturn infrared instrument study
NASA Technical Reports Server (NTRS)
1972-01-01
The Mariner Jupiter/Saturn infrared instrumentation conceptual design study was conducted to determine the physical and operational characteristics of the instruments needed to satisfy the experiment science requirements. The design of the instruments is based on using as many proven concepts as possible. Many design features are taken from current developments such as the Mariner, Pioneer 10, Viking Orbiter radiometers, and Nimbus D spectrometer. Calibration techniques and error analysis for the instrument system are discussed.
Knobelspiesse, Kirk; Cairns, Brian; Mishchenko, Michael; Chowdhary, Jacek; Tsigaridis, Kostas; van Diedenhoven, Bastiaan; Martin, William; Ottaviani, Matteo; Alexandrov, Mikhail
2012-09-10
Remote sensing of aerosol optical properties is difficult, but multi-angle, multi-spectral, polarimetric instruments have the potential to retrieve sufficient information about aerosols that they can be used to improve global climate models. However, the complexity of these instruments means that it is difficult to intuitively understand the relationship between instrument design and retrieval success. We apply a Bayesian statistical technique that relates instrument characteristics to the information contained in an observation. Using realistic simulations of fine size mode dominated spherical aerosols, we investigate three instrument designs. Two of these represent instruments currently in orbit: the Multiangle Imaging SpectroRadiometer (MISR) and the POLarization and Directionality of the Earths Reflectances (POLDER). The third is the Aerosol Polarimetry Sensor (APS), which failed to reach orbit during recent launch, but represents a viable design for future instruments. The results show fundamental differences between the three, and offer suggestions for future instrument design and the optimal retrieval strategy for current instruments. Generally, our results agree with previous validation efforts of POLDER and airborne prototypes of APS, but show that the MISR aerosol optical thickness uncertainty characterization is possibly underestimated.
Power calculator for instrumental variable analysis in pharmacoepidemiology
Walker, Venexia M; Davies, Neil M; Windmeijer, Frank; Burgess, Stephen; Martin, Richard M
2017-01-01
Abstract Background Instrumental variable analysis, for example with physicians’ prescribing preferences as an instrument for medications issued in primary care, is an increasingly popular method in the field of pharmacoepidemiology. Existing power calculators for studies using instrumental variable analysis, such as Mendelian randomization power calculators, do not allow for the structure of research questions in this field. This is because the analysis in pharmacoepidemiology will typically have stronger instruments and detect larger causal effects than in other fields. Consequently, there is a need for dedicated power calculators for pharmacoepidemiological research. Methods and Results The formula for calculating the power of a study using instrumental variable analysis in the context of pharmacoepidemiology is derived before being validated by a simulation study. The formula is applicable for studies using a single binary instrument to analyse the causal effect of a binary exposure on a continuous outcome. An online calculator, as well as packages in both R and Stata, are provided for the implementation of the formula by others. Conclusions The statistical power of instrumental variable analysis in pharmacoepidemiological studies to detect a clinically meaningful treatment effect is an important consideration. Research questions in this field have distinct structures that must be accounted for when calculating power. The formula presented differs from existing instrumental variable power formulae due to its parametrization, which is designed specifically for ease of use by pharmacoepidemiologists. PMID:28575313
NASA Technical Reports Server (NTRS)
1972-01-01
The selection and definition of candidate experiments and the associated experiment instrumentation requirements are described. Information is presented that addresses the following study objectives: (1) determine specific research and technology needs in the comm/nav field through a survey of the scientific/technical community; (2) develop manned low earth orbit space screening criteria and compile lists of potential candidate experiments; (3) in Blue Book format, define and describe selected candidate experiments in sufficient detail to develop laboratory configuration designs and layouts; and (4) develop experiment time phasing criteria and recommend a payload for sortie can/early laboratory missions.
ASON: An OWL-S based ontology for astrophysical services
NASA Astrophysics Data System (ADS)
Louge, T.; Karray, M. H.; Archimède, B.; Knödlseder, J.
2018-07-01
Modern astrophysics heavily relies on Web services to expose most of the data coming from many different instruments and researches worldwide. The virtual observatory (VO) has been designed to allow scientists to locate, retrieve and analyze useful information among those heterogeneous data. The use of ontologies has been studied in the VO context for astrophysical concerns like object types or astrophysical services subjects. On the operative point of view, ontological description of astrophysical services for interoperability and querying still has to be considered. In this paper, we design a global ontology (Astrophysical Services ONtology, ASON) based on web Ontology Language for Services (OWL-S) to enhance existing astrophysical services description. By expressing together VO specific and non-VO specific services design, it will improve the automation of services queries and allow automatic composition of heterogeneous astrophysical services.
Development and testing of airfoils for high-altitude aircraft
NASA Technical Reports Server (NTRS)
Drela, Mark (Principal Investigator)
1996-01-01
Specific tasks included airfoil design; study of airfoil constraints on pullout maneuver; selection of tail airfoils; examination of wing twist; test section instrumentation and layout; and integrated airfoil/heat-exchanger tests. In the course of designing the airfoil, specifically for the APEX test vehicle, extensive studies were made over the Mach and Reynolds number ranges of interest. It is intended to be representative of airfoils required for lightweight aircraft operating at extreme altitudes, which is the primary research objective of the APEX program. Also considered were thickness, pitching moment, and off-design behavior. The maximum ceiling parameter M(exp 2)C(sub L) value achievable by the Apex-16 airfoil was found to be a strong constraint on the pullout maneuver. The NACA 1410 and 2410 airfoils (inverted) were identified as good candidates for the tail, with predictable behavior at low Reynolds numbers and good tolerance to flap deflections. With regards to wing twist, it was decided that a simple flat wing was a reasonable compromise. The test section instrumentation consisted of surface pressure taps, wake rakes, surface-mounted microphones, and skin-friction gauges. Also, a modest wind tunnel test was performed for an integrated airfoil/heat-exchanger configuration, which is currently on Aurora's 'Theseus' aircraft. Although not directly related to the APEX tests, the aerodynamics or heat exchangers has been identified as a crucial aspect of designing high-altitude aircraft and hence is relevant to the ERAST program.
Advances in Digital Calibration Techniques Enabling Real-Time Beamforming SweepSAR Architectures
NASA Technical Reports Server (NTRS)
Hoffman, James P.; Perkovic, Dragana; Ghaemi, Hirad; Horst, Stephen; Shaffer, Scott; Veilleux, Louise
2013-01-01
Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable SweepSAR architectures, which promise significant increases in instrument capability for solid earth and biomass remote sensing. These new instrument concepts require new methods for calibrating the multiple channels, which are combined on-board, in real-time. The benefit of this effort is that it enables a new class of lightweight radar architecture, Digital Beamforming with SweepSAR, providing significantly larger swath coverage than conventional SAR architectures for reduced mass and cost. This paper will review the on-going development of the digital calibration architecture for digital beamforming radar instrument, such as the proposed Earth Radar Mission's DESDynI (Deformation, Ecosystem Structure, and Dynamics of Ice) instrument. This proposed instrument's baseline design employs SweepSAR digital beamforming and requires digital calibration. We will review the overall concepts and status of the system architecture, algorithm development, and the digital calibration testbed currently being developed. We will present results from a preliminary hardware demonstration. We will also discuss the challenges and opportunities specific to this novel architecture.
Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine
2017-12-01
Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Springston, Stephen R.
The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO 2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO 2 + hυ1 →SO 2 *→SO 2 + hυ2 The emitted light is proportional to the concentration of SO 2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed tomore » interface with external computers through the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. Brookhaven National Laboratory (BNL) has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.« less
Development of an audit instrument for nursing care plans in the patient record
Bjorvell, C; Thorell-Ekstrand, I; Wredling, R
2000-01-01
Objectives—To develop, validate, and test the reliability of an audit instrument that measures the extent to which patient records describe important aspects of nursing care. Material—Twenty records from each of three hospital wards were collected and audited. The auditors were registered nurses with a knowledge of nursing documentation in accordance with the VIPS model—a model designed to structure nursing documentation. (VIPS is an acronym formed from the Swedish words for wellbeing, integrity, prevention, and security.) Methods—An audit instrument was developed by determining specific criteria to be met. The audit questions were aimed at revealing the content of the patient for nursing assessment, nursing diagnosis, planned interventions, and outcome. Each of the 60 records was reviewed by the three auditors independently and the reliability of the instrument was tested by calculating the inter-rater reliability coefficient. Content validity was tested by using an expert panel and calculating the content validity ratio. The criterion related validity was estimated by the correlation between the score of the Cat-ch-Ing instrument and the score of an earlier developed and used audit instrument. The results were then tested by using Pearson's correlation coefficient. Results—The new audit instrument, named Cat-ch-Ing, consists of 17 questions designed to judge the nursing documentation. Both quantity and quality variables are judged on a rating scale from zero to three, with a maximum score of 80. The inter-rater reliability coefficients were 0.98, 0.98, and 0.92, respectively for each group of 20 records, the content validity ratio ranged between 0.20 and 1.0 and the criterion related validity showed a significant correlation of r = 0.68 (p< 0.0001, 95% CI 0.57 to 0.76) between the two audit instruments. Conclusion—The Cat-ch-Ing instrument has proved to be a valid and reliable audit instrument for nursing records when the VIPS model is used as the basis of the documentation. (Quality in Health Care 2000;9:6–13) Key Words: audit instrument; nursing care plans; quality assurance PMID:10848373
A haptic device for guide wire in interventional radiology procedures.
Moix, Thomas; Ilic, Dejan; Bleuler, Hannes; Zoethout, Jurjen
2006-01-01
Interventional Radiology (IR) is a minimally invasive procedure where thin tubular instruments, guide wires and catheters, are steered through the patient's vascular system under X-ray imaging. In order to perform these procedures, a radiologist has to be trained to master hand-eye coordination, instrument manipulation and procedure protocols. The existing simulation systems all have major drawbacks: the use of modified instruments, unrealistic insertion lengths, high inertia of the haptic device that creates a noticeably degraded dynamic behavior or excessive friction that is not properly compensated for. In this paper we propose a quality training environment dedicated to IR. The system is composed of a virtual reality (VR) simulation of the patient's anatomy linked to a robotic interface providing haptic force feedback. This paper focuses on the requirements, design and prototyping of a specific haptic interface for guide wires.
NASA Technical Reports Server (NTRS)
Blaney, D. L.
2002-01-01
The next stage of Mars exploration will include the use of rovers to seek out specific mineralogies. Understanding the mineralogical diversity of the locale will be used to determining which targets should be investigated with the full suite of in situ capability on the rover. Visible to Short Wavelength Infrared (VSWIR) spectroscopy is critical in evaluating the mineralogical diversity and to validate the global remote sensing data sets to be collected by Mars Express and the Mars Reconnaissance Orbiter. However, spectroscopy on mobile platforms present challenges in both the design of instruments and in the efficient operation of the instrument and mission. Field-testing and validation on Earth can be used to develop instrument requirements analysis tools needed for used on Mars.
Research in cosmic and gamma ray astrophysics
NASA Technical Reports Server (NTRS)
Stone, Edward C.; Mewaldt, Richard A.; Prince, Thomas A.
1992-01-01
Discussed here is research in cosmic ray and gamma ray astrophysics at the Space Radiation Laboratory (SRL) of the California Institute of Technology. The primary activities discussed involve the development of new instrumentation and techniques for future space flight. In many cases these instrumentation developments were tested in balloon flight instruments designed to conduct new investigations in cosmic ray and gamma ray astrophysics. The results of these investigations are briefly summarized. Specific topics include a quantitative investigation of the solar modulation of cosmic ray protons and helium nuclei, a study of cosmic ray positron and electron spectra in interplanetary and interstellar space, the solar modulation of cosmic rays, an investigation of techniques for the measurement and interpretation of cosmic ray isotopic abundances, and a balloon measurement of the isotopic composition of galactic cosmic ray boron, carbon, and nitrogen.
Keune, Lobke H; de Vogel, Vivienne; van Marle, Hjalmar J C
2016-01-01
To comply with the need for a more evidence based risk assessment and management in forensic mental health, an outcome monitor is being developed in the Dutch forensic psychiatric centre Van der Hoeven Kliniek in Utrecht, the Hoeven Outcome Monitor (HOM). Conform evidence based medicine (EBM) guidelines, the HOM is subdivided into three consecutive stages, (1) the evaluation stage, (2) the aetiology stage and (3) the implementation stage. In this article an account is provided for the design of the evaluation stage. To account for predicaments in previous research that pertain to a lack of uniformity and disregard of specific context- and patient-related characteristics, a macro-, meso- and micro-treatment evaluation instrument is developed. This instrument provides for the first step to build an evidence base for specific interventions and treatments in forensic psychiatry. Copyright © 2016 Elsevier Ltd. All rights reserved.
Measurement and valuation of quality of life in economic appraisal of cancer treatment.
Uyl-de Groot, C A; Rutten, F F; Bonsel, G J
1994-01-01
In the economic evaluation (EE) of technologies in cancer treatment at least three endpoints are relevant: costs, survival and quality of life (QoL). This article is focused on QoL. EE requires the use of generic and valuation QoL instruments at a disease non-specific level, but the inclusion of cancer-specific instruments may be advisable, particularly for reasons of explanation if changes in dimensions are small or conflicting. Given the pros and cons of the available questionnaires, we advocate the use of the Nottingham Health Profile, the EuroQol and the Rotterdam Symptom Checklist. In our experience the QoL issue in EE linked with cancer trials is associated with practical problems like questionnaire composition, follow-up time, interviewing schedule, patients' compliance and doctors' acceptance. These problems are discussed and some practical guidelines for the design of QoL measurement in cancer trials are given.
ORAC: 21st Century Observing at UKIRT
NASA Astrophysics Data System (ADS)
Bridger, A.; Wright, G. S.; Tan, M.; Pickup, D. A.; Economou, F.; Currie, M. J.; Adamson, A. J.; Rees, N. P.; Purves, M. H.
The Observatory Reduction and Acquisition Control system replaces all of the existing software which interacts with the observers at UKIRT. The aim is to improve observing efficiency with a set of integrated tools that take the user from pre-observing preparation, through the acquisition of observations to the reduction using a data-driven pipeline. ORAC is designed to be flexible and extensible, and is intended for use with all future UKIRT instruments, as well as existing telescope hardware and ``legacy'' instruments. It is also designed to allow integration with phase-1 and queue-scheduled observing tools in anticipation of possible future requirements. A brief overview of the project and its relationship to other systems is given. ORAC also re-uses much code from other systems and we discuss issues relating to the trade-off between reuse and the generation of new software specific to our requirements.
Sub-picowatt/kelvin resistive thermometry for probing nanoscale thermal transport.
Zheng, Jianlin; Wingert, Matthew C; Dechaumphai, Edward; Chen, Renkun
2013-11-01
Advanced instrumentation in thermometry holds the key for experimentally probing fundamental heat transfer physics. However, instrumentation with simultaneously high thermometry resolution and low parasitic heat conduction is still not available today. Here we report a resistive thermometry scheme with ~50 μK temperature resolution and ~0.25 pW/K thermal conductance resolution, which is achieved through schemes using both modulated heating and common mode noise rejection. The suspended devices used herein have been specifically designed to possess short thermal time constants and minimal attenuation effects associated with the modulated heating current. Furthermore, we have systematically characterized the parasitic background heat conductance, which is shown to be significantly reduced using the new device design and can be effectively eliminated using a "canceling" scheme. Our results pave the way for probing fundamental nanoscale thermal transport processes using a general scheme based on resistive thermometry.
ERIC Educational Resources Information Center
Oonk, Wil; Verloop, Nico; Gravemeijer, Koeno P. E.
2015-01-01
This study concentrated on the theory-practice problem in mathematics teacher education. We examined 13 student teachers' use of theory when they reflected on teaching practice in a class specifically designed to optimize the chance for theory use. We developed a Reflection Analysis Instrument with which the student teachers' use of theory could…
Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Hansman, R. John
1997-01-01
Pilot non-conformance to alerting system commands has been noted in general and to a TCAS-like collision avoidance system in a previous experiment. This paper details two experiments studying collision avoidance during closely-spaced parallel approaches in instrument meteorological conditions (IMC), and specifically examining possible causal factors of, and design solutions to, pilot non-conformance.
Omani Students' Views about Global Warming: Beliefs about Actions and Willingness to Act
ERIC Educational Resources Information Center
Ambusaidi, Abdullah; Boyes, Edward; Stanisstreet, Martin; Taylor, Neil
2012-01-01
A 44-item questionnaire was designed to determine students' views about how useful various "specific" actions might be in helping to reduce global warming, their willingness to undertake these various actions and the extent to which these two might be related. The instrument was administered to students in Grades 6 to 12 (N = 1532) from…
Speechreading Development in Deaf and Hearing Children: Introducing the Test of Child Speechreading
ERIC Educational Resources Information Center
Kyle, Fiona E.; Campbell, Ruth; Mohammed, Tara; Coleman, Mike; MacSweeney, Mairead
2013-01-01
Purpose: In this article, the authors describe the development of a new instrument, the Test of Child Speechreading (ToCS), which was specifically designed for use with deaf and hearing children. Speechreading is a skill that is required for deaf children to access the language of the hearing community. ToCS is a deaf-friendly, computer-based test…
ERIC Educational Resources Information Center
Wenno, Hendrik
2014-01-01
In designing the lesson teachers have to adapt the method or learning model with the material to be taught. In the teaching of measuring concept, students frequently faced with measuring instruments, micrometer, screw, scale, and so on. Direct Instruction Model would be suitable for teaching the measurement concepts specifically the skill of using…
The George C. Marshall Space Flight Center High Reynolds Number Wind Tunnel Technical Handbook
NASA Technical Reports Server (NTRS)
Gwin, H. S.
1975-01-01
The High Reynolds Number Wind Tunnel at the George C. Marshall Space Flight Center is described. The following items are presented to illustrate the operation and capabilities of the facility: facility descriptions and specifications, operational and performance characteristics, model design criteria, instrumentation and data recording equipment, data processing and presentation, and preliminary test information required.
ERIC Educational Resources Information Center
Simones, Lilian Lima
2017-01-01
Music performance in the higher educational context is shaped by a reciprocal chain of interactions between students, part-time tutors and full-time teaching staff, each with specific expectations about the teaching and learning process. Such expectations can provide valuable insights not only for designing and implementing meaningful educational…
ERIC Educational Resources Information Center
Manero, Borja; Torrente, Javier; Fernandez-Vara, Clara; Fernandez-Manjon, Baltasar
2017-01-01
This study examines the influence of players' age, gender, and gaming preferences and habits (from now on, "gaming preferences") on the effectiveness of a specific videogame that has been designed to increase the interest towards classical theater among teenagers. Using a validated instrument, participants were divided into four groups…
Lessons Learned about Liquid Metal Reactors from FFTF Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wootan, David W.; Casella, Andrew M.; Omberg, Ronald P.
2016-09-20
The Fast Flux Test Facility (FFTF) is the most recent liquid-metal reactor (LMR) to operate in the United States, from 1982 to 1992. FFTF is located on the DOE Hanford Site near Richland, Washington. The 400-MWt sodium-cooled, low-pressure, high-temperature, fast-neutron flux, nuclear fission test reactor was designed specifically to irradiate Liquid Metal Fast Breeder Reactor (LMFBR) fuel and components in prototypical temperature and flux conditions. FFTF played a key role in LMFBR development and testing activities. The reactor provided extensive capability for in-core irradiation testing, including eight core positions that could be used with independent instrumentation for the test specimens.more » In addition to irradiation testing capabilities, FFTF provided long-term testing and evaluation of plant components and systems for LMFBRs. The FFTF was highly successful and demonstrated outstanding performance during its nearly 10 years of operation. The technology employed in designing and constructing this reactor, as well as information obtained from tests conducted during its operation, can significantly influence the development of new advanced reactor designs in the areas of plant system and component design, component fabrication, fuel design and performance, prototype testing, site construction, and reactor operations. The FFTF complex included the reactor, as well as equipment and structures for heat removal, containment, core component handling and examination, instrumentation and control, and for supplying utilities and other essential services. The FFTF Plant was designed using a “system” concept. All drawings, specifications and other engineering documentation were organized by these systems. Efforts have been made to preserve important lessons learned during the nearly 10 years of reactor operation. A brief summary of Lessons Learned in the following areas will be discussed: Acceptance and Startup Testing of FFTF FFTF Cycle Reports« less
Instrumentation progress at the Giant Magellan Telescope project
NASA Astrophysics Data System (ADS)
Jacoby, George H.; Bernstein, R.; Bouchez, A.; Colless, M.; Crane, Jeff; DePoy, D.; Espeland, B.; Hare, Tyson; Jaffe, D.; Lawrence, J.; Marshall, J.; McGregor, P.; Shectman, Stephen; Sharp, R.; Szentgyorgyi, A.; Uomoto, Alan; Walls, B.
2016-08-01
Instrument development for the 24m Giant Magellan Telescope (GMT) is described: current activities, progress, status, and schedule. One instrument team has completed its preliminary design and is currently beginning its final design (GCLEF, an optical 350-950 nm, high-resolution and precision radial velocity echelle spectrograph). A second instrument team is in its conceptual design phase (GMACS, an optical 350-950 nm, medium resolution, 6-10 arcmin field, multi-object spectrograph). A third instrument team is midway through its preliminary design phase (GMTIFS, a near-IR YJHK diffraction-limited imager/integral-field-spectrograph), focused on risk reduction prototyping and design optimization. A fourth instrument team is currently fabricating the 5 silicon immersion gratings needed to begin its preliminary design phase (GMTNIRS, a simultaneous JHKLM high-resolution, AO-fed, echelle spectrograph). And, another instrument team is focusing on technical development and prototyping (MANIFEST, a facility robotic, multifiber feed, with a 20 arcmin field of view). In addition, a medium-field (6 arcmin, 0.06 arcsec/pix) optical imager will support telescope and AO commissioning activities, and will excel at narrow-band imaging. In the spirit of advancing synergies with other groups, the challenges of running an ELT instrument program and opportunities for cross-ELT collaborations are discussed.
A low cost, simple, portable instrument for the measurement of infra-red reflectance of paints
NASA Astrophysics Data System (ADS)
Marson, F.
1982-05-01
The construction and design of a low cost, simple, portable infra-red reflectometer which can be used to estimate the reflectance of paint films in the 800 nm region is described. The infra-red reflectances of a range of lustreless, semigloss and gloss olive drab camouflage paints determined using this instrument are compared to those obtained using modified commercial equipment and to the reflectances measured at 800 nm using a Cary model 17 spectrophotometer. The new reflectometer was shown to be superior to the modified commercial instrument currently specified in Australian government paint specifications and to be capable of estimating the reflectance of olive drab paints to within about one per cent of the Cary derived reflectance values. The reflectance values for a range of 24 experimental coatings made with pigments of varying absorption in the infra-red region are used to illustrate the effect of the instrument's spectral response and the necessity of establishing a reliable working standard.
Categorisation of full waveform data provided by laser scanning devices
NASA Astrophysics Data System (ADS)
Ullrich, Andreas; Pfennigbauer, Martin
2011-11-01
In 2004, a laser scanner device for commercial airborne laser scanning applications, the RIEGL LMS-Q560, was introduced to the market, making use of a radical alternative approach to the traditional analogue signal detection and processing schemes found in LIDAR instruments so far: digitizing the echo signals received by the instrument for every laser pulse and analysing these echo signals off-line in a so-called full waveform analysis in order to retrieve almost all information contained in the echo signal using transparent algorithms adaptable to specific applications. In the field of laser scanning the somewhat unspecific term "full waveform data" has since been established. We attempt a categorisation of the different types of the full waveform data found in the market. We discuss the challenges in echo digitization and waveform analysis from an instrument designer's point of view and we will address the benefits to be gained by using this technique, especially with respect to the so-called multi-target capability of pulsed time-of-flight LIDAR instruments.
Sarri, Grammati; Bhor, Menaka; Abogunrin, Seye; Farmer, Caroline; Nandal, Savita; Halloway, Rashid; Revicki, Dennis A
2018-05-21
Sickle cell disease (SCD) is a chronic condition associated with high mortality and morbidity. It is characterized by acute clinical symptoms such as painful vaso-occlusive crises, which can impair health-related quality of life (HRQL). This study was conducted to identify validated patient-reported outcome (PRO) instruments for use in future trials of potential treatments for SCD. A systematic literature review (SLR) was performed using MEDLINE and EMBASE to identify United States (US)-based studies published in English between 1997 and 2017 that reported on validated PRO instruments used in randomized controlled trials and real-world settings. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist was used to assess the quality of PRO instruments. The SLR included 21 studies assessing the psychometric properties of 24 PRO instruments. Fifteen of those instruments were developed and validated for adults and 10 for children (one instrument was used in both children and young adults aged up to 21 years). Only five of the 15 adult instruments and three of the 10 pediatric instruments were developed specifically for SCD. For most instruments, there were few or no data on validation conducted in SCD development cohorts. Of the 24 PRO instruments identified, 16 had strong internal reliability (Cronbach's α ≥0.80). There was often insufficient information to assess the content validity, construct validity, responsiveness, or test-retest reliability of the instruments identified for both child and adult populations. No validated PRO instruments measuring caregiver burden in SCD were identified. The evidence on the psychometric properties of PRO instruments was limited. However, the results of this SLR provide key information on such tools to help inform the design of future clinical trials for patients with SCD in the US.
Sensorization of a surgical robotic instrument for force sensing
NASA Astrophysics Data System (ADS)
Shahzada, Kaspar S.; Yurkewich, Aaron; Xu, Ran; Patel, Rajni V.
2016-03-01
This paper presents the development and application of an approach for sensorizing a surgical robotic instrument for two degree-of-freedom (DOF) lateral force sensing. The sensorized instrument is compatible with the da Vinci® Surgical System and can be used for skills assessment and force control in specific surgical tasks. The sensing technology utilizes a novel layout of four fiber Bragg grating (FBG) sensors attached to the shaft of a da Vinci® surgical instrument. The two cross-section layout is insensitive to error caused by combined force and torque loads, and the orientation of the sensors minimizes the condition number of the instrument's compliance matrix. To evaluate the instrument's sensing capabilities, its performance was tested using a commercially available force-torque sensor, and showed a resolution of 0.05N at 1 kHz sampling rate. The performance of the sensorized instrument was evaluated by performing three surgical tasks on phantom tissue using the da Vinci® system with the da Vinci Research Kit (dVRK): tissue palpation, knot tightening during suturing and Hem-O-Lok® tightening during knotless suturing. The tasks were designed to demonstrate the robustness of the sensorized force measurement approach. The paper reports the results of further evaluation by a group of expert and novice surgeons performing the three tasks mentioned above.
Birth of the Program for Array Seismic Studies of the Continental Lithosphere (PASSCAL)
NASA Astrophysics Data System (ADS)
James, D. E.; Sacks, I. S.
2002-05-01
As recently as 1984 institutions doing portable seismology depended upon their own complement of instruments, almost all designed and built in-house, and all of limited recording capability and flexibility. No data standards existed. Around 1980 the National Research Council (NRC) of the National Academy of Sciences (NAS), with National Science Foundation (NSF) support, empanelled a committee to study a major new initiative in Seismic Studies of the Continental Lithosphere (SSCL). The SSCL report in 1983 recommended that substantial numbers (1000 or more) of new generation digital seismographs be acquired for 3-D high resolution imaging of the continental lithosphere. Recommendations of the SSCL committee dovetailed with other NRC/NAS and NSF reports that highlighted imaging of the continental lithosphere as an area of highest priority. For the first time in the history of portable seismology the question asked was "What do seismologists need to do the job right?" A grassroots effort was undertaken to define instrumentation and data standards for a powerful new set of modern seismic research tools to serve the national seismological community. In the spring and fall of 1983 NSF and IASPEI sponsored workshops were convened to develop specifications for the design of a new generation of portable instrumentation. PASSCAL was the outgrowth of these seminal studies and workshops. The first step toward the formal formation of PASSCAL began with an ad-hoc organizing committee, comprised largely of the members of the NAS lithospheric seismology panel, convened by the authors at Carnegie Institution in Washington in November 1983. From that meeting emerged plans and promises of NSF support for an open organizational meeting to be held in January 1984, in Madison, Wisconsin. By the end of the two-day Madison meeting PASSCAL and an official consortium of seismological institutions for portable seismology were realities. Shortly after, PASSCAL merged with the complementary Global Seismic Network (GSN) under the overall umbrella of the Incorporated Research Institutions for Seismology (IRIS) consortium. Pre-startup funding for PASSCAL was provided by NSF via a so-called "Phase Zero" grant to the Carnegie Institution in June, 1984, to initiate design of new digital instrumentation and to facilitate preparation of the PASSCAL Program Plan. A working group met at Princeton in July 1984 to draft the PASSCAL Program Plan for the IRIS 10-year proposal to NSF, submitted in December 1984. PASSCAL functions as a national facility for seismological research, acquiring and maintaining a large complement of state-of-the-art portable instrumentation for scientists in member institutions. Within a year of its formation, PASSCAL had retained an engineer/program manager and begun the specification process for the manufacture and acquisition of a national instrumentation facility of broadband and short period seismographs. Instrument centers staffed by hardware and software engineers were established to maintain and distribute equipment, and to assist in field installations. By the late 1980s substantial volumes of standardized digital data were flowing from portable experiments to the archives of the newly formed Data Management Center (DMC). Portable broadband sensors built to PASSCAL specifications came on the market in 1989 and transformed the nature of portable experiments by expanding the technical capabilities of portable stations almost to the level of permanent global stations. Today PASSCAL through the instrument center at New Mexico Tech supports dozens of experiments worldwide for high resolution imaging of the earth's interior on all scales.
Health-Related Quality of Life in Persons With Ostomies Managed in an Outpatient Care Setting.
Santos, Vera Lucia Conceição de Gouveia; Augusto, Fabiana da Silva; Gomboski, Gustavo
2016-01-01
We examined health-related quality of life (HRQOL) in persons with ostomies receiving outpatient care. We also analyzed relationships among HRQOL, demographic, and pertinent clinical factors. We used a descriptive, exploratory, cross-sectional study design to collect and analyze data. Data in this article are a secondary analysis of data collected from a primary study, developed by Santos and Gomboski, on the adaptation and validation of the City of Hope-Quality of Life-Ostomy Questionnaire (COH-QOL-OQ) to the Portuguese language in Brazil. A convenience sample of 215 adults living with an ostomy was evaluated. Slightly more than half (51.6%) were men, 67.5% underwent colostomy surgery, and 59.1% underwent cancer-related ostomy surgery. Subjects received care in specialized health care units in 3 cities in the Brazilian state of Rio Grande do Sul. After approval by the Research Ethics Committee and permission from health care units, data were collected using 2 instruments: the World Health Organization Quality of Life-Short Version (WHOQOL-Bref) (generic HRQOL instrument) and the COH-QOL-OQ (disease specific HRQOL instrument). Data were analyzed using χ test and logistic regression (via a stepwise forward method). Patients were classified into 3 groups according to the means and standard deviations of the scores: low, moderate, and high quality of life (QOL). Ostomy patients had total scores of 69.6 ± 20.2 and 6.1 ± 1.4 for the WHOQOL-Bref and COH-QOL-OQ instruments, respectively. Patients with shorter times since their ostomy creation had worse scores on both the specific QOL (P = .006) and generic QOL (P = .019) instruments. Patients who did not practice religion (P = .027; odds ratio [OR] = 3.39) and those without a partner/spouse (P = .007; OR = 4.90) had increased probability of having worse scores on the WHOQOL-Bref (generic instrument). Persons living with ostomies were found to have scores indicating moderate HRQOL on a disease-specific and generic instrument. Shorter time since ostomy creation, lack of religious practice, and lack of a partner negatively influenced the HRQOL of these patients.
New Worlds Observer Telescope and Instrument Optical Design Concepts
NASA Technical Reports Server (NTRS)
Howard, Joseph M.; Noecker, Charlie; Kendrick, Steve; Woodgate, Bruce; Kilstron, Steve; Cash, Webster
2008-01-01
Optical design concepts for the telescope and instrumentation for NASA s New Worlds Observer program are presented. A four-meter multiple channel telescope is discussed, as well as a suite of science instrument concepts. Wide field instrumentation (imager and spectrograph) would be accommodated by a three-mirror-anastigmat telescope design. Planet finding and characterization, and a UV instrument would use a separate channel that is picked off after the first two mirrors (primary and secondary). Guiding concepts are also discussed.
Design and Requirements Creep In A Build-To-Print Mission
NASA Technical Reports Server (NTRS)
Peabody, Sharon A.; Otero, Veronica
2017-01-01
Build-to-Print designs, or rebuilds of flight proven designs, are attractive to mission stakeholders, as they give the appearance of minimal engineering development cost, risk, and schedule. The reality is that seldom is a project an exact duplicate of a predecessor. Mission reclassification, improvements in hardware, and science objective changes can all serve as a source of requirements and design creep and have ramifications often not fully anticipated during initial proposals. The Thermal Infrared Sensor Instrument (TIRS) was a late addition to the LandSat-8 program to provide infrared imaging to measure evapotranspiration for water cycle management. To meet the launch requirements for LandSat-8, instrument design life requirements were relaxed, the sensor development expedited, and technology development was minimized. Consequently, TIRS was designed as a higher risk instrument, with less redundancy than an instrument critical to mission success. After the successful LandSat-8 launch in 2013 and instrument performance, a rebuild of the instrument for the next LandSat spacecraft was included in the baseline mission success criteria. This paper discusses the technical challenges encountered during the rebuild of the TIRS-2 (Thermal Infrared Sensor 2) instrument and the resultant impacts on the thermal system design.
Landsat image data quality studies
NASA Technical Reports Server (NTRS)
Schueler, C. F.; Salomonson, V. V.
1985-01-01
Preliminary results of the Landsat-4 Image Data Quality Analysis (LIDQA) program to characterize the data obtained using the Thematic Mapper (TM) instrument on board the Landsat-4 and Landsat-5 satellites are reported. TM design specifications were compared to the obtained data with respect to four criteria, including spatial resolution; geometric fidelity; information content; and image relativity to Multispectral Scanner (MSS) data. The overall performance of the TM was rated excellent despite minor instabilities and radiometric anomalies in the data. Spatial performance of the TM exceeded design specifications in terms of both image sharpness and geometric accuracy, and the image utility of the TM data was at least twice as high as MSS data. The separability of alfalfa and sugar beet fields in a TM image is demonstrated.
Beresniak, Ariel; Auray, Jean-Paul; Duru, Gérard; Aractingi, Selim; Krueger, Gerald G; Talarico, Sergio; Tsutani, Kiichiro; Dupont, Danielle; de Linares, Yolaine
2015-09-01
The wide use of cosmetics and their perceived benefits upon well-being imply objective descriptions of their effects upon the different dimensions contributing to the quality of life (QoL). Such a goal pleas for using relevant and validated scientific instruments with robust measurement methods. This paper discusses the interest of the new validated questionnaire BeautyQoL specifically designed to assess the effect of cosmetic products on physical appearance and QoL. After conducting a review of skin appearance and QoL, three phases of the international codevelopment have been carried out in the following sequence: semi-directed interviews (Phase 1), acceptability study (Phase 2), and validation study (Phase 3). Data collection and validation process have been carried out in 16 languages. This review confirms that QoL instruments developed in dermatology are not suitable to assess cosmetic products, mainly because of their lack of sensitivity. General acceptability of BeautyQol was very good. Forty-two questions have been structured in five dimensions that explained 76.7% of the total variance: Social Life, Self-confidence, Mood, Vitality, and Attractiveness. Cronbach's alpha coefficients are between 0.932 and 0.978, confirming the good internal consistency of the results. The BeautyQol questionnaire is the first international instrument specific to cosmetic products and physical appearance that has been validated in 16 languages and could be used in a number of clinical trials and descriptive studies to demonstrate the added value of these products on the QoL. © 2015 Wiley Periodicals, Inc.
Design principles in telescope development: invariance, innocence, and the costs
NASA Astrophysics Data System (ADS)
Steinbach, Manfred
1997-03-01
Instrument design is, for the most part, a battle against errors and costs. Passive methods of error damping are in many cases effective and inexpensive. This paper shows examples of error minimization in our design of telescopes, instrumentation and evaluation instruments.
Design tradeoffs for a Multispectral Linear Array (MLA) instrument
NASA Technical Reports Server (NTRS)
Mika, A. M.
1982-01-01
The heart of the multispectral linear array (MLA) design problem is to develop an instrument concept which concurrently provides a wide field-of-view with high resolution, spectral separation with precise band-to band registration, and excellent radiometric accuracy. Often, these requirements have conflicting design implications which can only be resolved by careful tradeoffs that consider performance, cost, fabrication feasibility and development risk. The key design tradeoffs for an MLA instrument are addressed, and elements of a baseline instrument concept are presented.
A systematic review of substance misuse assessment packages.
Sweetman, Jennifer; Raistrick, Duncan; Mdege, Noreen D; Crosby, Helen
2013-07-01
Health-care systems globally are moving away from process measures of performance to payments for outcomes achieved. It follows that there is a need for a selection of proven quality tools that are suitable for undertaking comprehensive assessments and outcomes assessments. This review aimed to identify and evaluate existing comprehensive assessment packages. The work is part of a national program in the UK, Collaborations in Leadership of Applied Health Research and Care. Systematic searches were carried out across major databases to identify instruments designed to assess substance misuse. For those instruments identified, searches were carried out using the Cochrane Library, Embase, Ovid MEDLINE(®) and PsychINFO to identify articles reporting psychometric data. From 595 instruments, six met the inclusion criteria: Addiction Severity Index; Chemical Use, Abuse and Dependence Scale; Form 90; Maudsley Addiction Profile; Measurements in the Addictions for Triage and Evaluation; and Substance Abuse Outcomes Module. The most common reasons for exclusion were that instruments were: (i) designed for a specific substance (239); (ii) not designed for use in addiction settings (136); (iii) not providing comprehensive assessment (89); and (iv) not suitable as an outcome measure (20). The six packages are very different and suited to different uses. No package had adequate evaluation of their properties and so the emphasis should be on refining a small number of tools with very general application rather than creating new ones. An alternative to using 'off-the-shelf' packages is to create bespoke packages from well-validated, single-construct scales. [ © 2013 Australasian Professional Society on Alcohol and other Drugs.
Harris, Joshua D; Erickson, Brandon J; Cvetanovich, Gregory L; Abrams, Geoffrey D; McCormick, Frank M; Gupta, Anil K; Verma, Nikhil N; Bach, Bernard R; Cole, Brian J
2014-02-01
Condition-specific questionnaires are important components in evaluation of outcomes of surgical interventions. No condition-specific study methodological quality questionnaire exists for evaluation of outcomes of articular cartilage surgery in the knee. To develop a reliable and valid knee articular cartilage-specific study methodological quality questionnaire. Cross-sectional study. A stepwise, a priori-designed framework was created for development of a novel questionnaire. Relevant items to the topic were identified and extracted from a recent systematic review of 194 investigations of knee articular cartilage surgery. In addition, relevant items from existing generic study methodological quality questionnaires were identified. Items for a preliminary questionnaire were generated. Redundant and irrelevant items were eliminated, and acceptable items modified. The instrument was pretested and items weighed. The instrument, the MARK score (Methodological quality of ARticular cartilage studies of the Knee), was tested for validity (criterion validity) and reliability (inter- and intraobserver). A 19-item, 3-domain MARK score was developed. The 100-point scale score demonstrated face validity (focus group of 8 orthopaedic surgeons) and criterion validity (strong correlation to Cochrane Quality Assessment score and Modified Coleman Methodology Score). Interobserver reliability for the overall score was good (intraclass correlation coefficient [ICC], 0.842), and for all individual items of the MARK score, acceptable to perfect (ICC, 0.70-1.000). Intraobserver reliability ICC assessed over a 3-week interval was strong for 2 reviewers (≥0.90). The MARK score is a valid and reliable knee articular cartilage condition-specific study methodological quality instrument. This condition-specific questionnaire may be used to evaluate the quality of studies reporting outcomes of articular cartilage surgery in the knee.
An improved maximum permissible exposure meter for safety assessments of laser radiation
NASA Astrophysics Data System (ADS)
Corder, D. A.; Evans, D. R.; Tyrer, J. R.
1997-12-01
Current interest in laser radiation safety requires demonstration that a laser system has been designed to prevent exposure to levels of laser radiation exceeding the Maximum Permissible Exposure. In some simple systems it is possible to prove this by calculation, but in most cases it is preferable to confirm calculated results with a measurement. This measurement may be made with commercially available equipment, but there are limitations with this approach. A custom designed instrument is presented in which the full range of measurement issues have been addressed. Important features of the instrument are the design and optimisation of detector heads for the measurement task, and consideration of user interface requirements. Three designs for detector head are presented, these cover the majority of common laser types. Detector heads are designed to optimise the performance of relatively low cost detector elements for this measurement task. The three detector head designs are suitable for interfacing to photodiodes, low power thermopiles and pyroelectric detectors. Design of the user interface was an important aspect of the work. A user interface which is designed for the specific application minimises the risk of user error or misinterpretation of the measurement results. A palmtop computer was used to provide an advanced user interface. User requirements were considered in order that the final implement was well matched to the task of laser radiation hazard audits.
Multi-anode wire two dimensional proportional counter for detecting Iron-55 X-Ray Radiation
NASA Astrophysics Data System (ADS)
Weston, Michael William James
Radiation detectors in many applications use small sensor areas or large tubes which only collect one-dimensional information. There are some applications that require analyzing a large area and locating specific elements such as contamination on the heat tiles of a space shuttle or features on historical artifacts. The process can be time consuming and scanning a large area in a single pass is beneficial. The use of a two dimensional multi-wire proportional counter provides a large detection window presenting positional information in a single pass. This thesis described the design and implementation of an experimental detector to evaluate a specific design intended for use as a handheld instrument. The main effort of this research was to custom build a detector for testing purposes. The aluminum chamber and all circuit boards were custom designed and built specifically for this application. Various software and programmable logic algorithms were designed to analyze the raw data in real time and attempted to determine what data was useful and what could be discarded. The research presented here provides results useful for designing an improved second generation detector in the future. With the anode wire spacing chosen and the minimal collimation of the radiation source, detected events occurred all over the detection grid at any time. The raw event data did not make determining the source position easy and further data correlation was required. An abundance of samples had multiple wire hits which were not useful because it falsely reported the source to be all over the place and at different energy levels. By narrowing down the results to only use the largest signal pairs on different axes in each event, a much more accurate analysis of where the source existed above the grid was determined. The basic principle and construction method was shown to work, however the gas selection, geometry and anode wire constructs proved to be poor. To provide a system optimized for a specific application would require detailed Monte Carlo simulations. These simulation results together with the details and techniques implemented in this thesis would provide a final instrument of much higher accuracy.
Instruments measuring spirituality in clinical research: a systematic review.
Monod, Stéfanie; Brennan, Mark; Rochat, Etienne; Martin, Estelle; Rochat, Stéphane; Büla, Christophe J
2011-11-01
Numerous instruments have been developed to assess spirituality and measure its association with health outcomes. This study's aims were to identify instruments used in clinical research that measure spirituality; to propose a classification of these instruments; and to identify those instruments that could provide information on the need for spiritual intervention. A systematic literature search in MEDLINE, CINHAL, PsycINFO, ATLA, and EMBASE databases, using the terms "spirituality" and "adult$," and limited to journal articles was performed to identify clinical studies that used a spiritual assessment instrument. For each instrument identified, measured constructs, intended goals, and data on psychometric properties were retrieved. A conceptual and a functional classification of instruments were developed. Thirty-five instruments were retrieved and classified into measures of general spirituality (N = 22), spiritual well-being (N = 5), spiritual coping (N = 4), and spiritual needs (N = 4) according to the conceptual classification. Instruments most frequently used in clinical research were the FACIT-Sp and the Spiritual Well-Being Scale. Data on psychometric properties were mostly limited to content validity and inter-item reliability. According to the functional classification, 16 instruments were identified that included at least one item measuring a current spiritual state, but only three of those appeared suitable to address the need for spiritual intervention. Instruments identified in this systematic review assess multiple dimensions of spirituality, and the proposed classifications should help clinical researchers interested in investigating the complex relationship between spirituality and health. Findings underscore the scarcity of instruments specifically designed to measure a patient's current spiritual state. Moreover, the relatively limited data available on psychometric properties of these instruments highlight the need for additional research to determine whether they are suitable in identifying the need for spiritual interventions.
Designing communication and remote controlling of virtual instrument network system
NASA Astrophysics Data System (ADS)
Lei, Lin; Wang, Houjun; Zhou, Xue; Zhou, Wenjian
2005-01-01
In this paper, a virtual instrument network through the LAN and finally remote control of virtual instruments is realized based on virtual instrument and LabWindows/CVI software platform. The virtual instrument network system is made up of three subsystems. There are server subsystem, telnet client subsystem and local instrument control subsystem. This paper introduced virtual instrument network structure in detail based on LabWindows. Application procedure design of virtual instrument network communication, the Client/the programming mode of the server, remote PC and server communication far realizing, the control power of the workstation is transmitted, server program and so on essential technical were introduced. And virtual instruments network may connect to entire Internet on. Above-mentioned technology, through measuring the application in the electronic measurement virtual instrument network that is already built up, has verified the actual using value of the technology. Experiment and application validate that this design is resultful.
Ravindra, Vijay M; Wallace, Scott A; Vaidya, Rahul; Fox, W Christopher; Klugh, Arnett R; Puskas, David; Park, Min S
2016-02-01
The Role III, Multinational Medical Unit at Kandahar Air Field, Afghanistan, was established to provide combat casualty care in theater for International Security Assistance Forces, Afghanistan National Security Forces, and local nationals during Operation Enduring Freedom-Afghanistan. The authors describe their experience of treating unstable lumbar spine fractures with orthopedic extremity instrumentation sets from January 2007 to January 2008 and November 2010 to May 2011. During the study periods, 15 patients comprising Afghanistan National Security Forces and local nationals presented to the medical facility for treatment of unstable lumbar spine fractures. The patients underwent surgery for either anterior corpectomy and instrumented fusion (n = 5) or posterior instrumented fusion (n = 10). Because of periodic scarcity of spinal instrumentation sets, orthopedic extremity instrumentation sets were used (Synthes Large Fragment LCP Instrument and Implant Set) for spinal stabilization. Immediate postoperative standing and sitting plain radiographs demonstrated no evidence of fracture progression or immediate hardware failure. One patient was seen in follow-up at 4 weeks and demonstrated construct stability on follow-up radiographs. In the combat environment with sparse resources, unstable spine fractures may potentially be treated using instrumentation not specifically designed for spinal implantation. This is an off-label use, and the authors do not recommend the use of these techniques as standard treatment in most medical environments. Copyright © 2016 Elsevier Inc. All rights reserved.
SAO Participation in the GOME and SCIAMACHY Satellite Instrument Programs
NASA Technical Reports Server (NTRS)
Hilsenrath, Ernest (Technical Monitor); Chance, Kelly; Kurosu, Thomas
2004-01-01
This report summarizes the progress on our three-year program of research to refine the measurement capability for satellite-based instruments that monitor ozone and other trace species in the Earth's stratosphere and troposphere, to retrieve global distributions of these and other constituents h m the GOME and SCIAMACHY satellite instruments, and to conduct scientific studies for the ILAS instruments. This continues our involvements as a U.S. participant in GOME and SCIAMACHY since their inception, and as a member of the ILAS-II Science Team. These programs have led to the launch of the first satellite instrument specifically designed to measure height-resolved ozone, including the tropospheric component (GOME), and the development of the first satellite instrument that will measure tropospheric ozone simultaneously with NO2, CO, HCHO, N2O, H2O, and CH4 (SCIAMACHY). The GOME program now includes the GOME-2 instruments, to be launched on the Eumetsat Metop satellites, providing long-term continuity in European measurements of global ozone that complement the measurements of the TOMS, SBUV, OMI, OMPS instruments. The research primarily focuses on two areas: Data analysis, including algorithm development and validation studies that will improve the quality of retrieved data products, in support for future field campaigns (to complement in situ and airborne campaigns with satellite measurements), and scientific analyses to be interfaced to atmospheric modeling studies.
SAO Participation in the GOME and SCIAMACHY Satellite Instrument Programs
NASA Technical Reports Server (NTRS)
Chance, Kelly; Kurosu, Thomas
2003-01-01
This report summarizes the progress on our three-year program of research to refine the measurement capability for satellite-based instruments that monitor ozone and other trace species in the Earth's stratosphere and troposphere, to retrieve global distributions of these and other constituents from the GOME and SCIAMACHY satellite instruments, and to conduct scientific studies for the ILAS instruments. This continues our involvements as a U.S. participant in GOME and SCIAMACHY since their inception, and as a member of the ILAS-II Science Team. These programs have led to the launch of the first satellite instrument specifically designed to measure height-resolved ozone, including the tropospheric component (GOME), and the development of the first satellite instrument that will measure tropospheric ozone simultaneously with NO2, CO, HCHO, N2O, H2O, and CH4 (SCIAMACHY). The GOME program now includes the GOME-2 instruments, to be launched on the Eumetsat Metop satellites, providing long-term continuity in European measurements of global ozone that complement the measurements of the TOMS, SBW, OMI, OMPS instruments. The research primarily focuses on two areas: Data analysis, including algorithm development and validation studies that will improve the quality of retrieved data products, in support for future field campaigns (to complement in situ and airborne campaigns with satellite measurements), and scientific analyses to be interfaced to atmospheric modeling studies.
The Colorado Student Space Weather Experiment : A CubeSat for Space Physics
NASA Astrophysics Data System (ADS)
Palo, Scott; Li, Xinlin; Gerhardt, David; Turner, Drew; Hoxie, V.; Kohnert, Rick; Batiste, Susan
Energetic particles, electrons and protons either directly associated with solar flares or trapped in the terrestrial radiation belt, have a profound space weather impact. A National Science Foundation supported 3U CubeSat mission with a single instrument, Relativistic Electrons and Proton Telescope integrated little experiment (REPTile), is proposed to address fundamental scientific questions relating to these high energy particles. Of key importance are the relation-ship between solar flares and energetic particles and the acceleration and loss mechanism of outer radiation belt electrons. REPTile, operating in a highly inclined low earth orbit, will measure differential fluxes of relativistic electrons in the energy range of 0.5-3.5 MeV and pro-tons in 10-40 MeV. The Colorado Student Space Weather Experiment cubesat will be designed, integrated and testing by students at the University of Colorado under the oversight of pro-fessional engineers with the Laboratory of Atmospheric and Space Physics who have extensive space hardware experience. Our design philosophy is to use commercially off the shelf (COTS) parts where available and only engage in detailed designed where COTS parts cannot meet the system needs. The top level science requirements for the mission have driven the system and subsystem level performance requirements and the specific design choices such as a passive magnetic attitude system and instrument design. In this paper we will present details of the CSSWE design and management approach. Specifically we will discuss the top level science requirements for the mission and show that these measurements are novel and will address open questions in the scientific community. The overall system architecture resulting from a flow-down of these requirements will be presented with a focus on the novel aspects of the system including the instrument design. Finally we will discuss how this project is organized and man-aged as part of the Department of Aerospace Engineering graduate projects course sequence along with the integration of professional engineers in the program. It is often underappreciated that the management of a student project, given the transient nature of the students in the program, is more challenging than many of the technical aspects. We will discuss our process to managing this project risk along with our pedagological philosophy for student learning and its relationship to a small satellite program.
Calibration, characterization, and first results with the Ocean PHILLS hyperspectral imager
NASA Astrophysics Data System (ADS)
Davis, Curtiss O.; Kappus, Mary E.; Bowles, Jeffrey H.; Fisher, John; Antoniades, John A.; Carney, Megan
1999-10-01
The Ocean Portable Hyperspectral Imager for Low-Light spectroscopy (Ocean PHILLS), is a new hyperspectral imager specifically designed for imaging the coastal ocean. It uses a thinned, backside illuminated CCD for high sensitivity, and an all-reflective spectrograph with a convex grating in an Offner configuration to produce a distortion free image. Here we describe the instrument design and present the results of laboratory calibration and characterization and example results from a two week field experiment imaging the coastal waters off Lee Stocking, Island, Bahamas.
Investigation of Space Based Solid State Coherent Lidar
NASA Technical Reports Server (NTRS)
Amzajerdian, Farzin
2002-01-01
This report describes the work performed over the period of October 1, 1997 through March 31, 2001. Under this contract, UAH/CAO participated in defining and designing the SPAce Readiness Coherent Lidar Experiment (SPARCLE) mission, and developed the instrument's optical subsystem. This work was performed in collaborative fashion with NASA/MSFC engineers at both UAH/CAO and NASA/MSFC facilities. Earlier work by the UAH/CAO had produced a preliminary top-level system design for the Shuttle lidar instrument meeting the proposed mission performance requirements and the Space Shuttle Hitchhiker canister volume constraints. The UAH/CAO system design efforts had concentrated on the optical and mechanical designs of the instrument. The instrument electronics were also addressed, and the major electronic components and their interfaces defined. The instrument design concept was mainly based on the state of the transmitter and local oscillator laser development at NASA Langley Research Center and Jet Propulsion Laboratory, and utilized several lidar-related technologies that were either developed or evaluated by the NASA/MSFC and UAH/CAO scientists. UAH/CAO has developed a comprehensive coherent lidar numerical model capable of analyzing the performance of different instrument and mission concepts. This model uses the instrument configuration, atmospheric conditions and current velocity estimation theory to provide prediction of instrument performance during different phases of operation. This model can also optimize the design parameters of the instrument.
Optimizing Orbit-Instrument Configuration for Global Precipitation Mission (GPM) Satellite Fleet
NASA Technical Reports Server (NTRS)
Smith, Eric A.; Adams, James; Baptista, Pedro; Haddad, Ziad; Iguchi, Toshio; Im, Eastwood; Kummerow, Christian; Einaudi, Franco (Technical Monitor)
2001-01-01
Following the scientific success of the Tropical Rainfall Measuring Mission (TRMM) spearheaded by a group of NASA and NASDA scientists, their external scientific collaborators, and additional investigators within the European Union's TRMM Research Program (EUROTRMM), there has been substantial progress towards the development of a new internationally organized, global scale, and satellite-based precipitation measuring mission. The highlights of this newly developing mission are a greatly expanded scope of measuring capability and a more diversified set of science objectives. The mission is called the Global Precipitation Mission (GPM). Notionally, GPM will be a constellation-type mission involving a fleet of nine satellites. In this fleet, one member is referred to as the "core" spacecraft flown in an approximately 70 degree inclined non-sun-synchronous orbit, somewhat similar to TRMM in that it carries both a multi-channel polarized passive microwave radiometer (PMW) and a radar system, but in this case it will be a dual frequency Ku-Ka band radar system enabling explicit measurements of microphysical DSD properties. The remainder of fleet members are eight orbit-synchronized, sun-synchronous "constellation" spacecraft each carrying some type of multi-channel PMW radiometer, enabling no worse than 3-hour diurnal sampling over the entire globe. In this configuration the "core" spacecraft serves as a high quality reference platform for training and calibrating the PMW rain retrieval algorithms used with the "constellation" radiometers. Within NASA, GPM has advanced to the pre-formulation phase which has enabled the initiation of a set of science and technology studies which will help lead to the final mission design some time in the 2003 period. This presentation first provides an overview of the notional GPM program and mission design, including its organizational and programmatic concepts, scientific agenda, expected instrument package, and basic flight architecture. Following this introduction, we focus specifically on the last topic, that being an analysis which leads to an optimal flight architecture dictated in part by science requirements but constrained by allowable orbital mechanics, instrument scan patterns, and antenna aperture properties. Because the optimal architecture involves an interplay between orbit mechanics and instrument specifications, it is important to recognize that in attempting to serve various scientific themes, the final optimal architecture will represent a compromise concerning dynamic range, spatial resolution, sampling interval, pointing, beam coincidence, and measurement uncertainty. Moreover, cost becomes a major factor in seeking the optimal architecture through the pathways of antenna and instrument scan designs, as well as propulsion requirements associated with the orbit heights of various "constellation" members. Although the results presented at the IGARSS-2001 meeting will likely not be the fully refined flight architecture specifications, they are expected to be nearly complete.
The Planned Soil Moisture Active Passive (SMAP) Mission L-Band Radar/Radiometer Instrument
NASA Technical Reports Server (NTRS)
Spencer, Michael; Wheeler, Kevin; Chan, Samuel; Piepmeier, Jeffrey; Hudson, Derek; Medeiros, James
2011-01-01
The Soil Moisture Active/Passive (SMAP) mission is a NASA mission identified by the NRC 'decadal survey' to measure both soil moisture and freeze/thaw state from space. The mission will use both active radar and passive radiometer instruments at L-Band. In order to achieve a wide swath at sufficiently high resolution for both active and passive channels, an instrument architecture that uses a large rotating reflector is employed. The instrument system has completed the preliminary design review (PDR) stage, and detailed instrument design has begun. In addition to providing an overview of the instrument design, two recent design modifications are discussed: 1) The addition of active thermal control to the instrument spun side to provide a more stable, settable thermal environment for the radiometer electronics, and 2) A 'sequential transmit' strategy for the two radar polarization channels which allows a single high-power amplifier to be used.
An operational satellite scatterometer for wind vector measurements over the ocean
NASA Technical Reports Server (NTRS)
Grantham, W. L.; Bracalente, E. M.; Jones, W. L.; Schrader, J. H.; Schroeder, L. C.; Mitchell, J. L.
1975-01-01
Performance requirements and design characteristics of a microwave scatterometer wind sensor for measuring surface winds over the oceans on a global basis are described. Scatterometer specifications are developed from user requirements of wind vector measurement range and accuracy, swath width, resolution cell size and measurement grid spacing. A detailed analysis is performed for a baseline fan-beam scatterometer design, and its performance capabilities for meeting the SeaSat-A user requirements. Various modes of operation are discussed which will allow the resolution of questions concerning the effects of sea state on the scatterometer wind sensing ability and to verify design boundaries of the instrument.
Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers
NASA Technical Reports Server (NTRS)
Bos, Brent
2011-01-01
A document discusses a new parity pupil mask design that allows users to unambiguously determine the image space coordinate system of all the James Webb Space Telescope (JWST) science instruments by using two out-of-focus images. This is an improvement over existing mask designs that could not completely eliminate the coordinate system parity ambiguity at a wavelength of 5.6 microns. To mitigate the problem of how the presence of diffraction artifacts can obscure the pupil mask detail, this innovation has been created with specifically designed edge features so that the image space coordinate system parity can be determined in the presence of diffraction, even at long wavelengths.
Patterson, P Daniel; Weaver, Matthew D; Fabio, Anthony; Teasley, Ellen M; Renn, Megan L; Curtis, Brett R; Matthews, Margaret E; Kroemer, Andrew J; Xun, Xiaoshuang; Bizhanova, Zhadyra; Weiss, Patricia M; Sequeira, Denisse J; Coppler, Patrick J; Lang, Eddy S; Higgins, J Stephen
2018-02-15
This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. A systematic review study design was used and searched six databases, including one website. The research question guiding the search was developed a priori and registered with the PROSPERO database of systematic reviews: "Are there reliable and valid instruments for measuring fatigue among EMS personnel?" (2016:CRD42016040097). The primary outcome of interest was criterion-related validity. Important outcomes of interest included reliability (e.g., internal consistency), and indicators of sensitivity and specificity. Members of the research team independently screened records from the databases. Full-text articles were evaluated by adapting the Bolster and Rourke system for categorizing findings of systematic reviews, and the rated data abstracted from the body of literature as favorable, unfavorable, mixed/inconclusive, or no impact. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology was used to evaluate the quality of evidence. The search strategy yielded 1,257 unique records. Thirty-four unique experimental and non-experimental studies were determined relevant following full-text review. Nineteen studies reported on the reliability and/or validity of ten different fatigue survey instruments. Eighteen different studies evaluated the reliability and/or validity of four different sleepiness survey instruments. None of the retained studies reported sensitivity or specificity. Evidence quality was rated as very low across all outcomes. In this systematic review, limited evidence of the reliability and validity of 14 different survey instruments to assess the fatigue and/or sleepiness status of EMS personnel and related shift worker groups was identified.
Instrument Display Visual Angles for Conventional Aircraft and the MQ-9 Ground Control Station
NASA Technical Reports Server (NTRS)
Kamine, Tovy Haber; Bendrick, Gregg A.
2008-01-01
Aircraft instrument panels should be designed such that primary displays are in optimal viewing location to minimize pilot perception and response time. Human Factors engineers define three zones (i.e. cones ) of visual location: 1) "Easy Eye Movement" (foveal vision); 2) "Maximum Eye Movement" (peripheral vision with saccades), and 3) "Head Movement (head movement required). Instrument display visual angles were measured to determine how well conventional aircraft (T-34, T-38, F- 15B, F-16XL, F/A-18A, U-2D, ER-2, King Air, G-III, B-52H, DC-10, B747-SCA) and the MQ-9 ground control station (GCS) complied with these standards, and how they compared with each other. Selected instrument parameters included: attitude, pitch, bank, power, airspeed, altitude, vertical speed, heading, turn rate, slip/skid, AOA, flight path, latitude, longitude, course, bearing, range and time. Vertical and horizontal visual angles for each component were measured from the pilot s eye position in each system. The vertical visual angles of displays in conventional aircraft lay within the cone of "Easy Eye Movement" for all but three of the parameters measured, and almost all of the horizontal visual angles fell within this range. All conventional vertical and horizontal visual angles lay within the cone of Maximum Eye Movement. However, most instrument vertical visual angles of the MQ-9 GCS lay outside the cone of Easy Eye Movement, though all were within the cone of Maximum Eye Movement. All the horizontal visual angles for the MQ-9 GCS were within the cone of "Easy Eye Movement". Most instrument displays in conventional aircraft lay within the cone of Easy Eye Movement, though mission-critical instruments sometimes displaced less important instruments outside this area. Many of the MQ-9 GCS systems lay outside this area. Specific training for MQ-9 pilots may be needed to avoid increased response time and potential error during flight. The learning objectives include: 1) Know three physiologic cones of eye/head movement; 2) Understand how instrument displays comply with these design principles in conventional aircraft and an uninhabited aerial vehicle system. Which of the following is NOT a recognized physiologic principle of instrument display design? Cone of Easy Eye Movement 2) Cone of Binocular Eye Movement 3) Cone of Maximum Eye Movement 4) Cone of Head Movement 5) None of the above. Answer: # 2) Cone of Binocular Eye Movement
Optical turbulence profiling with Stereo-SCIDAR for VLT and ELT
NASA Astrophysics Data System (ADS)
Osborn, J.; Wilson, R. W.; Sarazin, M.; Butterley, T.; Chacón, A.; Derie, F.; Farley, O. J. D.; Haubois, X.; Laidlaw, D.; LeLouarn, M.; Masciadri, E.; Milli, J.; Navarrete, J.; Townson, M. J.
2018-07-01
Knowledge of the Earth's atmospheric optical turbulence is critical for astronomical instrumentation. Not only does it enable performance verification and optimization of the existing systems, but it is required for the design of future instruments. As a minimum this includes integrated astro-atmospheric parameters such as seeing, coherence time, and isoplanatic angle, but for more sophisticated systems such as wide-field adaptive optics enabled instrumentation the vertical structure of the turbulence is also required. Stereo-SCIDAR (Scintillation Detection and Ranging) is a technique specifically designed to characterize the Earth's atmospheric turbulence with high-altitude resolution and high sensitivity. Together with ESO (European Southern Observatory), Durham University has commissioned a Stereo-SCIDAR instrument at Cerro Paranal, Chile, the site of the Very Large Telescope (VLT), and only 20 km from the site of the future Extremely Large Telescope (ELT). Here we provide results from the first 18 months of operation at ESO Paranal including instrument comparisons and atmospheric statistics. Based on a sample of 83 nights spread over 22 months covering all seasons, we find the median seeing to be 0.64″ with 50 per cent of the turbulence confined to an altitude below 2 km and 40 per cent below 600 m. The median coherence time and isoplanatic angle are found as 4.18 ms and 1.75″, respectively. A substantial campaign of inter-instrument comparison was also undertaken to assure the validity of the data. The Stereo-SCIDAR profiles (optical turbulence strength and velocity as a function of altitude) have been compared with the Surface-Layer Slope Detection And Ranging, Multi-Aperture Scintillation Sensor-Differential Image Motion Monitor, and the European Centre for Medium Range Weather Forecasts model. The correlation coefficients are between 0.61 (isoplanatic angle) and 0.84 (seeing).
Modular Seafloor and Water Column Systems for the Ocean Observatories Initiative Cabled Array
NASA Astrophysics Data System (ADS)
Delaney, J. R.; Manalang, D.; Harrington, M.; Tilley, J.; Dosher, J.; Cram, G.; Harkins, G.; McGuire, C.; Waite, P.; McRae, E.; McGinnis, T.; Kenney, M.; Siani, C.; Michel-Hart, N.; Denny, S.; Boget, E.; Kawka, O. E.; Daly, K. L.; Luther, D. S.; Kelley, D. S.; Milcic, M.
2016-02-01
Over the past decade, cabled ocean observatories have become an increasingly important way to collect continuous real-time data at remote subsea locations. This has led to the development of a class of subsea systems designed and built specifically to distribute power and bandwidth among sensing instrumentation on the seafloor and throughout the water column. Such systems are typically powered by shore-based infrastructure and involve networks of fiber optic and electrical cabling that provide real-time data access and control of remotely deployed instrumentation. Several subsea node types were developed and/or adapted for cabled use in order to complete the installation of the largest North American scientific cabled observatory in Oct, 2014. The Ocean Observatories Initiative (OOI) Cabled Array, funded by the US National Science Foundation, consists of a core infrastructure that includes 900 km of fiber optic/electrical cables, seven primary nodes, 18 seafloor junction boxes, three mooring-mounted winched profiling systems, and three wire-crawling profiler systems. In aggregate, the installed infrastructure has 200 dedicated scientific instrument ports (of which 120 are currently assigned), and is capable of further expansion. The installed system has a 25-year design life for reliable, sustained monitoring; and all nodes, profilers and instrument packages are ROV-serviceable. Now in it's second year of operation, the systems that comprise the Cabled Array are providing reliable, 24/7 real-time data collection from deployed instrumentation, and offer a modular and scalable class of subsea systems for ocean observing. This presentation will provide an overview of the observatory-class subsystems of the OOI Cabled Array, focusing on the junction boxes, moorings and profilers that power and communicate with deployed instrumentation.
Shemilt, Ian; Hollands, Gareth J; Marteau, Theresa M; Nakamura, Ryota; Jebb, Susan A; Kelly, Michael P; Suhrcke, Marc; Ogilvie, David
2013-01-01
Unhealthy diet and low levels of physical activity are common behavioural factors in the aetiology of many non-communicable diseases. Recent years have witnessed an upsurge of policy and research interest in the use of taxes and other economic instruments to improve population health. To assemble, configure and analyse empirical research studies available to inform the public health case for using economic instruments to promote dietary and physical activity behaviour change. We conducted a systematic scoping review of evidence for the effects of specific interventions to change, or general exposure to variations in, prices or income on dietary and physical activity behaviours and corollary outcomes. Systematic electronic searches and parallel snowball searches retrieved >1 million study records. Text mining technologies were used to prioritise title-abstract records for screening. Eligible studies were selected, classified and analysed in terms of key characteristics and principal findings, using a narrative, configuring synthesis focused on implications for policy and further research. We identified 880 eligible studies, including 192 intervention studies and 768 studies that incorporated evidence for prices or income as correlates or determinants of target outcomes. Current evidence for the effects of economic instruments and exposures on diet and physical activity is limited in quality and equivocal in terms of its policy implications. Direct evidence for the effects of economic instruments is heavily skewed towards impacts on diet, with a relative lack of evidence for impacts on physical activity. The evidence-based case for using economic instruments to promote dietary and physical activity behaviour change may be less compelling than some proponents have claimed. Future research should include measurement of people's actual behavioural responses using study designs capable of generating reliable causal inferences regarding intervention effects. Policy implementation needs to be carefully aligned with evaluation planning and design.
Walters, Stephen John; Stern, Cindy; Robertson-Malt, Suzanne
2016-04-01
There is a growing call by consumers and governments for healthcare to adopt systems and approaches to care to improve patient safety. Collaboration within healthcare settings is an important factor for improving systems of care. By using validated measurement instruments a standardized approach to assessing collaboration is possible, otherwise it is only an assumption that collaboration is occurring in any healthcare setting. The objective of this review was to evaluate and compare measurement properties of instruments that measure collaboration within healthcare settings, specifically those which have been psychometrically tested and validated. Participants could be healthcare professionals, the patient or any non-professional who contributes to a patient's care, for example, family members, chaplains or orderlies. The term participant type means the designation of any one participant; for example 'nurse', 'social worker' or 'administrator'. More than two participant types was mandatory. The focus of this review was the validity of tools used to measure collaboration within healthcare settings. The types of studies considered for inclusion were validation studies, but quantitative study designs such as randomized controlled trials, controlled trials and case studies were also eligible for inclusion. Studies that focused on Interprofessional Education, were published as an abstract only, contained patient self-reporting only or were not about care delivery were excluded. The outcome of interest was validation and interpretability of the instrument being assessed and included content validity, construct validity and reliability. Interpretability is characterized by statistics such as mean and standard deviation which can be translated to a qualitative meaning. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in this review. The databases searched included PubMed, CINAHL, Embase, Cochrane Central Register of Controlled Trials, Emerald Fulltext, MD Consult Australia, PsycARTICLES, Psychology and Behavioural Sciences Collection, PsycINFO, Informit Health Databases, Scopus, UpToDate and Web of Science. The search for unpublished studies included EThOS (Electronic Thesis Online Service), Index to Theses and ProQuest- Dissertations and Theses. The assessment of methodological quality of the included studies was undertaken using the COSMIN checklist which is a validated tool that assesses the process of design and validation of healthcare measurement instruments. An Excel spreadsheet version of COSMIN was developed for data collection which included a worksheet for extracting participant characteristics and interpretability data. Statistical pooling of data was not possible for this review. Therefore, the findings are presented in a narrative form including tables and figures to aid in data presentation. To make a synthesis of the assessments of methodological quality of the different studies, each instrument was rated by accounting for the number of studies performed with an instrument, the appraisal of methodological quality and the consistency of results between studies. Twenty-one studies of 12 instruments were included in the review. The studies were diverse in their theoretical underpinnings, target population/setting and measurement objectives. Measurement objectives included: investigating beliefs, behaviors, attitudes, perceptions and relationships associated with collaboration; measuring collaboration between different levels of care or within a multi-rater/target group; assessing collaboration across teams; or assessing internal participation of both teams and patients.Studies produced validity or interpretability data but none of the studies assessed all validity and reliability properties. However, most of the included studies produced a factor structure or referred to prior factor analysis. A narrative synthesis of the individual study factor structures was generated consisting of nine headings: organizational settings, support structures, purpose and goals; communication; reflection on process; cooperation; coordination; role interdependence and partnership; relationships; newly created professional activities; and professional flexibility. Among the many instruments that measure collaboration within healthcare settings, the quality of each instrument varies; instruments are designed for specific populations and purposes, and are validated in various settings. Selecting an instrument requires careful consideration of the qualities of each. Therefore, referring to systematic reviews of measurement properties of instruments may be helpful to clinicians or researchers in instrument selection. Systematic reviews of measurement properties of instruments are valuable in aiding in instrument selection. This systematic review may be useful in instrument selection for the measurement of collaboration within healthcare settings with a complex mix of participant types. Evaluating collaboration provides important information on the strengths and limitations of different healthcare settings and the opportunities for continuous improvement via any remedial actions initiated. Development of a tool that can be used to measure collaboration within teams of healthcare professionals and non-professionals is important for practice. The use of different statistical modelling techniques, such as Item Response Theory modelling and the translation of models into Computer Adaptive Tests, may prove useful. Measurement equivalence is an important consideration for future instrument development and validation. Further development of the COSMIN tool should include appraisal for measurement equivalence. Researchers developing and validating measurement tools should consider multi-method research designs.
Software design for the VIS instrument onboard the Euclid mission: a multilayer approach
NASA Astrophysics Data System (ADS)
Galli, E.; Di Giorgio, A. M.; Pezzuto, S.; Liu, S. J.; Giusi, G.; Li Causi, G.; Farina, M.; Cropper, M.; Denniston, J.; Niemi, S.
2014-07-01
The Euclid mission scientific payload is composed of two instruments: a VISible Imaging Instrument (VIS) and a Near Infrared Spectrometer and Photometer instrument (NISP). Each instrument has its own control unit. The Instrument Command and Data Processing Unit (VI-CDPU) is the control unit of the VIS instrument. The VI-CDPU is connected directly to the spacecraft by means of a MIL-STD-1553B bus and to the satellite Mass Memory Unit via a SpaceWire link. All the internal interfaces are implemented via SpaceWire links and include 12 high speed lines for the data provided by the 36 focal plane CCDs readout electronics (ROEs) and one link to the Power and Mechanisms Control Unit (VI-PMCU). VI-CDPU is in charge of distributing commands to the instrument sub-systems, collecting their housekeeping parameters and monitoring their health status. Moreover, the unit has the task of acquiring, reordering, compressing and transferring the science data to the satellite Mass Memory. This last feature is probably the most challenging one for the VI-CDPU, since stringent constraints about the minimum lossless compression ratio, the maximum time for the compression execution and the maximum power consumption have to be satisfied. Therefore, an accurate performance analysis at hardware layer is necessary, which could delay too much the design and development of software. In order to mitigate this risk, in the multilayered design of software we decided to design a middleware layer that provides a set of APIs with the aim of hiding the implementation of the HW connected layer to the application one. The middleware is built on top of the Operating System layer (which includes the Real-Time OS that will be adopted) and the onboard Computer Hardware. The middleware itself has a multi-layer architecture composed of 4 layers: the Abstract RTOS Adapter Layer (AOSAL), the Speci_c RTOS Adapter Layer (SOSAL), the Common Patterns Layer (CPL), the Service Layer composed of two subgroups which are the Common Service (CSL) and the Specific Service layer (SSL). The middleware design is made using the UML 2.0 standard. The AOSAL includes the abstraction of services provided by a generic RTOS (e.g Thread/Task, Time Management, Mutex and Semaphores) as well as an abstraction of SpaceWire and 1553-B bus Interface. The SOSAL is the implementation of AOSAL for the adopted RTOS. The CPL provides a set of patterns that are a general solution for common problems related to embedded hard Real Time systems. This set includes patterns for memory management, homogenous redundancy channels, pipes and filters for data exchange, proxies for slow memories, watchdog and reactive objects. The CPL is designed using a soft-metamodeling approach, so as to be as general as possible. Finally, the SL provides a set of services that are common to space applications. The testing of this middleware can be done both during the design using appropriate tools of analysis and in the implementation phase by means of unit testing tools.
NASA Technical Reports Server (NTRS)
Blonksi, Slawomir; Gasser, Gerald; Russell, Jeffrey; Ryan, Robert; Terrie, Greg; Zanoni, Vicki
2001-01-01
Multispectral data requirements for Earth science applications are not always studied rigorously studied before a new remote sensing system is designed. A study of the spatial resolution, spectral bandpasses, and radiometric sensitivity requirements of real-world applications would focus the design onto providing maximum benefits to the end-user community. To support systematic studies of multispectral data requirements, the Applications Research Toolbox (ART) has been developed at NASA's Stennis Space Center. The ART software allows users to create and assess simulated datasets while varying a wide range of system parameters. The simulations are based on data acquired by existing multispectral and hyperspectral instruments. The produced datasets can be further evaluated for specific end-user applications. Spectral synthesis of multispectral images from hyperspectral data is a key part of the ART software. In this process, hyperspectral image cubes are transformed into multispectral imagery without changes in spatial sampling and resolution. The transformation algorithm takes into account spectral responses of both the synthesized, broad, multispectral bands and the utilized, narrow, hyperspectral bands. To validate the spectral synthesis algorithm, simulated multispectral images are compared with images collected near-coincidentally by the Landsat 7 ETM+ and the EO-1 ALI instruments. Hyperspectral images acquired with the airborne AVIRIS instrument and with the Hyperion instrument onboard the EO-1 satellite were used as input data to the presented simulations.
NASA Technical Reports Server (NTRS)
OsowskiNeil, Doreen; Yee, Jeng-Hwa; Boldt, John; Edwards, David
2010-01-01
We present the progress toward an analytical performance model of a 2.3 micron infrared correlation radiometer (IRCRg) prototype subsystem for a future geostationary space-borne instrument. The prototype is designed specifically to measure carbon monoxide (CO) from geostationary orbit. NASA's Geostationary Coastal and Air Pollution Events (GEO-CAPE) mission, one of the United States Earth Science and Applications Decadal Survey missions, specifies the use of infrared correlation radiometry to measure CO in two spectral regions for this mission. GEO-CAPE will use the robust IRCR measurement technique at geostationary orbit, nearly 50 times farther away than the Terra/MOPITT orbit, to determine hourly changes in CO across a continental domain. The abundance of CO in Earth's troposphere directly affects the concentration of hydroxyl, which regulates the lifetimes of many tropospheric pollutants. In addition, CO is a precursor to ozone formation; CO is used as a tracer to study the transport of global and regional pollutants; and CO is used as an indicator of both natural and anthropogenic air pollution sources and sinks. We have structured our development project to enable rapid evaluation of future spaceborne instrument designs. The project is part of NASA's Instrument Incubator Program. We describe the architecture of the performance model and the planned evaluation of the performance model using laboratory test data.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-17
... Specifications (STS) to define a new time limit for restoring inoperable RCS leakage detection instrumentation to... operability of the RCS leakage detection instrumentation. The CLIIP model SE will facilitate expedited... Operability Requirements and Actions for RCS Leakage Instrumentation'' AGENCY: Nuclear Regulatory Commission...
The development of a clinical outcomes survey research application: Assessment Center.
Gershon, Richard; Rothrock, Nan E; Hanrahan, Rachel T; Jansky, Liz J; Harniss, Mark; Riley, William
2010-06-01
The National Institutes of Health sponsored Patient-Reported Outcome Measurement Information System (PROMIS) aimed to create item banks and computerized adaptive tests (CATs) across multiple domains for individuals with a range of chronic diseases. Web-based software was created to enable a researcher to create study-specific Websites that could administer PROMIS CATs and other instruments to research participants or clinical samples. This paper outlines the process used to develop a user-friendly, free, Web-based resource (Assessment Center) for storage, retrieval, organization, sharing, and administration of patient-reported outcomes (PRO) instruments. Joint Application Design (JAD) sessions were conducted with representatives from numerous institutions in order to supply a general wish list of features. Use Cases were then written to ensure that end user expectations matched programmer specifications. Program development included daily programmer "scrum" sessions, weekly Usability Acceptability Testing (UAT) and continuous Quality Assurance (QA) activities pre- and post-release. Assessment Center includes features that promote instrument development including item histories, data management, and storage of statistical analysis results. This case study of software development highlights the collection and incorporation of user input throughout the development process. Potential future applications of Assessment Center in clinical research are discussed.
van der Mei, Sijrike F; Dijkers, Marcel P J M; Heerkens, Yvonne F
2011-12-01
To examine to what extent the concept and the domains of participation as defined in the International Classification of Functioning, Disability and Health (ICF) are represented in general cancer-specific health-related quality of life (HRQOL) instruments. Using the ICF linking rules, two coders independently extracted the meaningful concepts of ten instruments and linked these to ICF codes. The proportion of concepts that could be linked to ICF codes ranged from 68 to 95%. Although all instruments contained concepts linked to Participation (Chapters d7-d9 of the classification of 'Activities and Participation'), the instruments covered only a small part of all available ICF codes. The proportion of ICF codes in the instruments that were participation related ranged from 3 to 35%. 'Major life areas' (d8) was the most frequently used Participation Chapter, with d850 'remunerative employment' as the most used ICF code. The number of participation-related ICF codes covered in the instruments is limited. General cancer-specific HRQOL instruments only assess social life of cancer patients to a limited degree. This study's information on the content of these instruments may guide researchers in selecting the appropriate instrument for a specific research purpose.
The city of hope-quality of life-ostomy questionnaire: persian translation and validation.
Anaraki, F; Vafaie, M; Behboo, R; Esmaeilpour, S; Maghsoodi, N; Safaee, A; Grant, M
2014-07-01
Since there is no disease-specific instrument for measuring quality-of-life (QOL) in Ostomy patients in Persian language. This study was designed to translate and evaluate the validity and reliability of City of Hope-quality of life-Ostomy questionnaire (COH-QOL-Ostomy questionnaire). This study was designed as cross-sectional study. Reliability of the subscales and the summary scores were demonstrated by intra-class correlation coefficients. Pearson's correlations of an item with its own scale and other scales were calculated to evaluated convergent and discriminant validity. Clinical validity was also evaluated by known-group comparisons. Cronbach's alpha coefficient for all subscales was about 0.70 or higher. Results of interscale correlation were satisfactory and each subscale only measured a single and specified trait. All subscales met the standards of convergent and discriminant validity. Known group comparison analysis showed significant differences in social and spiritual well-being. The findings confirmed the reliability and validity of Persian version of COH-QOL-Ostomy questionnaire. The instrument was also well received by the Iranian patients. It can be considered as a valuable instrument to assess the different aspects of health related quality-of-life in Ostomy patients and used in clinical research in the future.
High-Resolution Spectroscopy at the Wyoming Infrared Observatory: Setting TESS Science on FHiRE
NASA Astrophysics Data System (ADS)
Jang-Condell, Hannah; Pierce, Michael J.; Pilachowski, C. A.; Kobulnicky, Henry; McLane, Jacob N.
2018-01-01
The Fiber High Resolution Echelle (FHiRE) spectrograph is a new instrument designed for the 2.3-m Wyoming InfraRed Observatory (WIRO). With the construction of a vacuum chamber for FHiRE to stabilize the spectrograph and a temperature-stabilized Thorium-Argon lamp for precise velocity calibration, we will be able to achieve 1 m/s RV precision, making it an ideal instrument for finding exoplanets. Details of the design of FHiRE are presented in a companion poster (Pierce et al.). The construction of this instrument is well-timed with the planned 2018 launch of NASA's Transiting Exoplanet Survey Satellite (TESS) mission. TESS will require a great deal of follow-up spectroscopy to characterize potential exoplanet host stars as well as radial velocity measurements to confirm new exoplanets. WIRO is ideally suited to acquire the long-term, high-cadence observations that will be required to make progress in this frontier area of astrophysics. We will coordinate our efforts with the TESS Follow-up Observing Program (TFOP), specifically as part of the Recon Spectroscopy and Precise Radial Velocity Work sub-groups.This work is supported by a grant from NASA EPSCOR.
Development of a relatchable cover mechanism for a cryogenic IR-sensor
NASA Technical Reports Server (NTRS)
Birner, R.; Lange, G.; Roth, M.; Voit, A.
1991-01-01
A cover mechanism for use on the Infrared Background Signature Survey (IBSS) cryostat was developed. The IBSS IR-instrument is scheduled for STS launch in early 1991 as a payload of the Shuttle Payload Satellite (SPS) 2. The cover is hinged, with a motorized rope drive. During ground processing, launch, entry, and landing, the cryostat, which houses the IR-instrument, is required to be a sealed vacuum tight container for cooling purposes and contamination prevention. When on orbit, the cover is opened to provide an unobstructed field of view for the IR-instrument. A positive seal is accomplished through the use of latch mechanism. The cover and the latch are driven by a common redundant actuator consisting of dc motors, spur gears, and a differential gear. Hall probe limit switches and position sensors (rotary variable transformer) are used to determine the position of the cover and the latch. The cover mechanism was successfully qualified for thermal vacuum (-25 to 35 C), acoustic noise, vibration (6 Gs sine, 9.7 G RMS) and life cycles. Constricting requirements, mechanical and electronic control design, specific design details, test results of functional performance, and environmental and life tests are described.
Assessing patient capacity to consent to treatment: an integrative review of instruments and tools.
Lamont, Scott; Jeon, Yun-Hee; Chiarella, Mary
2013-09-01
To provide a narrative synthesis of research findings on instruments or tools designed to aid assessment of patient capacity to consent to treatment. Capacity assessment is of significant priority within health care as a finding of incapacity is a vehicle for the removal of many of an individual's fundamental rights. Despite there being many instruments and tools available to aid health professionals in the assessment of patient capacity, there are no standardised guidelines from professional bodies that inform the assessment of mental capacity. Integrative review. Primary studies of instruments or tools concerning assessment of patient capacity to consent to treatment, published in English in peer-reviewed journals between January 2005-December 2010, were included in the review. Review papers of capacity assessment instruments were included for years including and prior to 2006. Nineteen instruments were found which assess patient capacity to consent. Key themes were identified in terms of capacity domains assessed, psychometric properties, instrument implementation, patient populations studied and instrument versus clinician judgement. Despite a plethora of capacity assessment instruments and tools available, only a small number of instruments were found to have demonstrated both reliability and validity. Further research is required to improve the validity of existing capacity assessment instruments. Increased attention to patient rights and autonomy arguably places a considerable burden on healthcare professionals to facilitate capacity assessments across a continuum of health care. Despite a plethora of capacity assessment instruments and tools being available to healthcare professionals, a comprehensive assessment requires time and is often difficult in the acute care setting. A strictly formulaic approach to the assessment of capacity is unlikely to capture specific individual nuances; therefore, capacity assessment instruments should support, but not replace, experienced clinical judgement. © 2013 John Wiley & Sons Ltd.
Duprez, Veerle; De Pover, Marleen; De Spiegelaere, Marc; Beeckman, Dimitri
2014-02-01
To develop a set of psychometrically sound instruments to assess knowledge, self-management and self-efficacy of diabetic patients. Furthermore, a survey to evaluate the satisfaction about diabetes education for patients was developed and tested. Treatment and secondary prevention of diabetes require a complex combination of care components. Patients' education has been accepted to improve diabetes knowledge, self-management and self-efficacy. Psychometrically sound instruments are needed to measure these patient-centred outcomes. Psychometric instrument validation. The first phase included a systematic literature review to develop the instruments. Content validity was evaluated using a two-round Delphi procedure involving diabetes experts. The content validity of the instruments was excellent. In a second phase, a convenience sample of 188 diabetic patients in two hospitals in one specific care region in Belgium participated in the psychometric evaluation. The criterion-related validity and internal consistency reliability were evaluated. The study produced a 21-item knowledge instrument, reflecting knowledge about 'glycemic control' and 'medico-social management aspects'. The self-management instrument included 32 statements, reflecting 'treatment and compliance' and 'general lifestyle'. The self-efficacy instrument included 30 items, reflecting 'nutrition', 'treatment' and 'regimen'. The patient satisfaction survey included 36 items, reflecting satisfaction about the relationship among the diabetes specialist, the diabetes educator, podiatrist and dietician. An instrument set with sound psychometric characteristics was developed to assess knowledge, self-management and self-efficacy of diabetic patients. Future studies should focus on the association between the instrument outcomes and clinical patient outcomes. The current instrument can support the design of educational interventions and training programmes and reduce inconsistencies in the information that patients receive. Furthermore, the instruments can be used for benchmarking the quality of diabetic patient education. © 2013 Blackwell Publishing Ltd.
Carnley, Mark V.; Fulford, Janice M.; Brooks, Myron H.
2013-01-01
The Level TROLL 100 manufactured by In-Situ Inc. was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to the manufacturer’s accuracy specifications for measuring pressure throughout the device’s operating temperature range. The Level TROLL 100 is a submersible, sealed, water-level sensing device with an operating pressure range equivalent to 0 to 30 feet of water over a temperature range of −20 to 50 degrees Celsius (°C). The device met the manufacturer’s stated accuracy specifications for pressure within its temperature-compensated operating range of 0 to 50 °C. The device’s accuracy specifications did not meet established USGS requirements for primary water-stage sensors used in the operation of streamgages, but the Level TROLL 100 may be suitable for other hydrologic data-collection applications. As a note, the Level TROLL 100 is not designed to meet USGS accuracy requirements. Manufacturer accuracy specifications were evaluated, and the procedures followed and the results obtained are described in this report. USGS accuracy requirements are routinely examined and reported when instruments are evaluated at the HIF.
Vázquez, Gustavo Héctor; Romero, Ester; Fabregues, Fernando; Pies, Ronald; Ghaemi, Nassir; Mota-Castillo, Manuel
2010-01-01
Bipolar disorder is commonly misdiagnosed, perhaps more so in Latin American and Spanish-speaking populations than in the United States. The Bipolar Spectrum Diagnostic Scale (BSDS) is a 19-item screening instrument designed to assist in screening for all types of bipolar disorder. The authors investigated the sensitivity of a Spanish-language version of the BSDS in a cohort of 65 outpatients with a diagnosis of bipolar disorder, based on a semi-structured interview and Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision criteria. To determine specificity, we assessed a control group of 36 outpatients with diagnosis of unipolar major depressive disorder. The overall sensitivity of the BSDS Spanish version with bipolar disorders types I, II, and NOS was 0.70, which was slightly lower than the sensitivity in the study using the English version of the BSDS (0.76). The specificity was 0.89. When the threshold was decreased from 13 to 12, the sensitivity of the Spanish BSDS increased to 0.76 and specificity dropped to 0.81. The Spanish version of the BSDS is promising as a screening instrument in Spanish-speaking populations. Copyright 2010 Elsevier Inc. All rights reserved.
Orthodontic instrument sterilization with microwave irradiation.
Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram
2015-04-01
This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups - Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min.
Orthodontic instrument sterilization with microwave irradiation
Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram
2015-01-01
Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686
ERIC Educational Resources Information Center
Bradley, Banks; And Others
A systematic procedure for obtaining objective data of nonverbal teaching behaviors focusing on specific behaviors is presented. Teacher behaviors, recorded on video-tape, are studied and evaluated for the following nonverbal behaviors: (1) use of proximity control in maintaining discipline; (2) emphasis on the need for eye contact as a speaker;…
ERIC Educational Resources Information Center
Vlachopoulos, Symeon P.; Michailidou, Sotiria
2006-01-01
The development process and initial validation of the Basic Psychological Needs in Exercise Scale (BPNES) are presented in this study. The BPNES is a domain-specific self-report instrument designed to assess perceptions of the extent to which the innate needs for autonomy, competence, and relatedness (Deci & Ryan, 2000) are satisfied in…
Ceramic vacuum tubes for geothermal well logging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, R.D.
1977-01-01
Useful design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes are discussed for application to the development of high temperature well logs. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data are presented in the appendix.
Think small - In large numbers. [microspacecraft missions
NASA Technical Reports Server (NTRS)
Jones, Ross M.
1989-01-01
The development and use of microspacecraft are examined. It is proposed that 10-50 microspacecraft per year can be launched; up to 50 microspacecraft can be dispatched with traditional launchers; and 1-3 experiments can be performed on the spacecraft. Various applications for the microspacecraft are discussed and specific examples of proposed missions are presented. Some systems and instruments designed for the microspacecraft are described.
ERIC Educational Resources Information Center
Guyard, Audrey; Michelsen, Susan I.; Arnaud, Catherine; Lyons, Alan; Cans, Christine; Fauconnier, Jerome
2012-01-01
Living with a child with a disability can affect family life in various domains. Impacts on time, expenses, work, relationships within the family, social relationships and physical and psychological health can be observed. The Family Impact of Childhood Disability (FICD) is a specific instrument designed to assess this situation. Used in a…
Multi-Disciplinary Ocean Sensors for Environmental Analyses and Networks (MOSEAN)
2004-01-01
will require optimization for their application . Modifications will include: a) Size and power reduction of the electro-fluidic component to match...be configured for detection of CDOM, phycocyanin , phycoerythrin, and chlorophyll-a depending upon the specific wavelengths chosen. Efforts on this...OPL in Santa Barbara. Discussions centered on new instrumentation designed for coastal applications and plans for the CHARM mooring (site selection
Construction Of Critical Thinking Skills Test Instrument Related The Concept On Sound Wave
NASA Astrophysics Data System (ADS)
Mabruroh, F.; Suhandi, A.
2017-02-01
This study aimed to construct test instrument of critical thinking skills of high school students related the concept on sound wave. This research using a mixed methods with sequential exploratory design, consists of: 1) a preliminary study; 2) design and review of test instruments. The form of test instruments in essay questions, consist of 18 questions that was divided into 5 indicators and 8 sub-indicators of the critical thinking skills expressed by Ennis, with questions that are qualitative and contextual. Phases of preliminary study include: a) policy studies; b) survey to the school; c) and literature studies. Phases of the design and review of test instruments consist of two steps, namely a draft design of test instruments include: a) analysis of the depth of teaching materials; b) the selection of indicators and sub-indicators of critical thinking skills; c) analysis of indicators and sub-indicators of critical thinking skills; d) implementation of indicators and sub-indicators of critical thinking skills; and e) making the descriptions about the test instrument. In the next phase of the review test instruments, consist of: a) writing about the test instrument; b) validity test by experts; and c) revision of test instruments based on the validator.
Meadows, Anthony; Burns, Debra S; Perkins, Susan M
2015-01-01
Previous research has demonstrated modest benefits from music-based interventions, specifically music and imagery interventions, during cancer care. However, little attention has been paid to measuring the benefits of music-based interventions using measurement instruments specifically designed to account for the multidimensional nature of music-imagery experiences. The purpose of this study was to describe the development of, and psychometrically evaluate, the Music Therapy Self-Rating Scale (MTSRS) as a measure for cancer patients engaged in supportive music and imagery interventions. An exploratory factor analysis using baseline data from 76 patients who consented to participate in a music-based intervention study during chemotherapy. Factor analysis of 14 items revealed four domains: Awareness of Body, Emotionally Focused, Personal Resources, and Treatment Specific. Internal reliability was excellent (Cronbach alphas ranging from 0.75 to 0.88) and construct and divergent-discriminant validity supported. The MTSRS is a psychometrically sound, brief instrument that captures essential elements of patient experience during music and imagery interventions. © the American Music Therapy Association 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Hook, Simon J.
1995-01-01
A lightweight, rugged, high-spectral-resolution interferometer has been built by Designs and Prototypes based on a set of specifications provided by the Jet Propulsion Laboratory and Dr. J. W. Salisbury (Johns Hopkins University). The instrument, the micro Fourier Transform Interferometer (mFTIR), permits the acquisition of infrared spectra of natural surfaces. Such data can be used to validate low and high spectral resolution data acquired remotely from aircraft and spacecraft in the 3-5 mm and 8-14 mm atmospheric window. The instrument has a spectral resolutions of 6 wavenumbers, weighs 16 kg including batteries and computer, and can be operated easily by two people in the field. Laboratory analysis indicates the instrument is spectrally calibrated to better than 1 wavenumber and the radiometric accuracy is <0.5 K if the radiances from the blackbodies used for calibration bracket the radiance from the sample.
A New Airborne Submillimetre Demonstrator
NASA Astrophysics Data System (ADS)
Lee, Clare; Baran, Anthony; Fox, Stuart; Harlow, Chawn; King, Rob; Rogers, Stuart; Rule, Ian
2013-12-01
ISMAR (International SubMillimetre Airborne Radiometer) is a new aircraft remote sensing instrument, with heterodyne receivers from 118 to 664GHz. It has been funded by the Met Office and ESA, and has been designed to allow additional channels to be added, including 874GHz. Submillimetre frequencies are very sensitive to ice clouds and can provide direct retrievals of Ice Water Path [1] which is an important parameter in General Circulation Models. ISMAR will be used as a satellite demonstrator as well as for investigating specific scientific case studies. It can be used in the preparation for the usage of Ice Cloud Imager (ICI) data on MetOp- SG and for calibration/validation post satellite launch. The instrument has been certified on the FAAM BAe- 146 aircraft and is currently undergoing a channel upgrade. This paper describes the instrument, its applications and the future aircraft campaign plans.
Design and development of a cross-cultural disposition inventory
NASA Astrophysics Data System (ADS)
Davies, Randall; Zaugg, Holt; Tateishi, Isaku
2015-01-01
Advances in technology have increased the likelihood that engineers will have to work in a global, culturally diverse setting. Many schools of engineering are currently revising their curricula to help students to develop cultural competence. However, our ability to measure cultural dispositions can be a challenge. The purpose of this project was to develop and test an instrument that measures the various aspects of cultural disposition. The results of the validation process verified that the hypothesised model adequately represented the data. The refined instrument produced a four-factor model for the overall construct. The validation process for the instrument verified the existence of specific subcomponents that form the overall cultural disposition construct. There also seems to be a hierarchical relationship within the subcomponents of cultural disposition. Additional research is needed to explore which aspects of cultural disposition affect an individual's ability to work effectively in a culturally diverse engineering team.
Josset, Jean-Luc; Westall, Frances; Hofmann, Beda A; Spray, John; Cockell, Charles; Kempe, Stephan; Griffiths, Andrew D; De Sanctis, Maria Cristina; Colangeli, Luigi; Koschny, Detlef; Föllmi, Karl; Verrecchia, Eric; Diamond, Larryn; Josset, Marie; Javaux, Emmanuelle J; Esposito, Francesca; Gunn, Matthew; Souchon-Leitner, Audrey L; Bontognali, Tomaso R R; Korablev, Oleg; Erkman, Suren; Paar, Gerhard; Ulamec, Stephan; Foucher, Frédéric; Martin, Philippe; Verhaeghe, Antoine; Tanevski, Mitko; Vago, Jorge L
The Close-Up Imager (CLUPI) onboard the ESA ExoMars Rover is a powerful high-resolution color camera specifically designed for close-up observations. Its accommodation on the movable drill allows multiple positioning. The science objectives of the instrument are geological characterization of rocks in terms of texture, structure, and color and the search for potential morphological biosignatures. We present the CLUPI science objectives, performance, and technical description, followed by a description of the instrument's planned operations strategy during the mission on Mars. CLUPI will contribute to the rover mission by surveying the geological environment, acquiring close-up images of outcrops, observing the drilling area, inspecting the top portion of the drill borehole (and deposited fines), monitoring drilling operations, and imaging samples collected by the drill. A status of the current development and planned science validation activities is also given. Key Words: Mars-Biosignatures-Planetary Instrumentation. Astrobiology 17, 595-611.
Howle, Timothy C; Dimmock, James A; Whipp, Peter R; Jackson, Ben
2015-06-01
With the aim of advancing the literature on impression management in physical activity settings, we developed a theoretically derived 2 by 2 instrument that was designed to measure different types of context-specific self-presentation motives. Following item generation and expert review (Study 1), the instrument was completed by 206 group exercise class attendees (Study 2) and 463 high school physical education students (Study 3). Our analyses supported the intended factor structure (i.e., reflecting acquisitive-agentic, acquisitive-communal, protective-agentic, and protective-communal motives). We found some support for construct validity, and the self-presentation motives were associated with variables of theoretical and applied interest (e.g., impression motivation and construction, social anxiety, social and achievement goals, efficacy beliefs, engagement). Taken together, the results indicate that the Self-presentation Motives for Physical Activity Questionnaire (SMPAQ) may be useful for measuring various types of self-presentation motives in physical activity settings.
Ran, Qin; Matsiev, Daniel; Wodtke, Alec M; Auerbach, Daniel J
2007-10-01
We describe an advanced and highly sensitive instrument for quantum state-resolved molecule-surface energy transfer studies under ultrahigh vacuum (UHV) conditions. The apparatus includes a beam source chamber, two differential pumping chambers, and a UHV chamber for surface preparation, surface characterization, and molecular beam scattering. Pulsed and collimated supersonic molecular beams are generated by expanding target molecule mixtures through a home-built pulsed nozzle, and excited quantum state-selected molecules were prepared via tunable, narrow-band laser overtone pumping. Detection systems have been designed to measure specific vibrational-rotational state, time-of-flight, angular and velocity distributions of molecular beams coming to and scattered off the surface. Facilities are provided to clean and characterize the surface under UHV conditions. Initial experiments on the scattering of HCl(v = 0) from Au(111) show many advantages of this new instrument for fundamental studies of the energy transfer at the gas-surface interface.
Compact, passively Q-switched Nd:YAG laser for the MESSENGER mission to Mercury.
Krebs, Danny J; Novo-Gradac, Anne-Marie; Li, Steven X; Lindauer, Steven J; Afzal, Robert S; Yu, Anthony W
2005-03-20
A compact, passively Q-switched Nd:YAG laser has been developed for the Mercury Laser Altimeter, an instrument on the Mercury Surface, Space Environment, Geochemistry, and Ranging mission to the planet Mercury. The laser achieves 5.4% efficiency with a near-diffraction-limited beam. It passed all space-flight environmental tests at subsystem, instrument, and satellite integration testing and successfully completes a postlaunch aliveness check en route to Mercury. The laser design draws on a heritage of previous laser altimetry missions, specifically the Ice Cloud and Elevation Satellite and the Mars Global Surveyor, but incorporates thermal management features unique to the requirements of an orbit of the planet Mercury.
Space shuttle data handling and communications considerations.
NASA Technical Reports Server (NTRS)
Stoker, C. J.; Minor, R. G.
1971-01-01
Operational and development flight instrumentation, data handling subsystems and communication requirements of the space shuttle orbiter are discussed. Emphasis is made on data gathering methods, crew display data, computer processing, recording, and telemetry by means of a digital data bus. Also considered are overall communication conceptual system aspects and design features allowing a proper specification of telemetry encoders and instrumentation recorders. An adaptive bit rate concept is proposed to handle the telemetry bit rates which vary with the amount of operational and experimental data to be transmitted. A split-phase encoding technique is proposed for telemetry to cope with the excessive bit jitter and low bit transition density which may affect television performance.
NASA Technical Reports Server (NTRS)
Truscello, V.
1972-01-01
A major concern in the integration of a radioisotope thermoelectric generator (RTG) with a spacecraft designed to explore the outer planets is the effect of the emitted radiation on the normal operation of scientific instruments. The necessary techniques and tools developed to allow accurate calculation of the neutron and gamma spectrum emanating from the RTG. The specific sources of radiation were identified and quantified. Monte Carlo techniques are then employed to perform the nuclear transport calculations. The results of these studies are presented. An extensive experimental program was initiated to measure the response of a number of scientific components to the nuclear radiation.
Blind detection of giant pulses: GPU implementation
NASA Astrophysics Data System (ADS)
Ait-Allal, Dalal; Weber, Rodolphe; Dumez-Viou, Cédric; Cognard, Ismael; Theureau, Gilles
2012-01-01
Radio astronomical pulsar observations require specific instrumentation and dedicated signal processing to cope with the dispersion caused by the interstellar medium. Moreover, the quality of observations can be limited by radio frequency interference (RFI) generated by Telecommunications activity. This article presents the innovative pulsar instrumentation based on graphical processing units (GPU) which has been designed at the Nançay Radio Astronomical Observatory. In addition, for giant pulsar search, we propose a new approach which combines a hardware-efficient search method and some RFI mitigation capabilities. Although this approach is less sensitive than the classical approach, its advantage is that no a priori information on the pulsar parameters is required. The validation of a GPU implementation is under way.
GET: A generic electronics system for TPCs and nuclear physics instrumentation
NASA Astrophysics Data System (ADS)
Pollacco, E. C.; Grinyer, G. F.; Abu-Nimeh, F.; Ahn, T.; Anvar, S.; Arokiaraj, A.; Ayyad, Y.; Baba, H.; Babo, M.; Baron, P.; Bazin, D.; Beceiro-Novo, S.; Belkhiria, C.; Blaizot, M.; Blank, B.; Bradt, J.; Cardella, G.; Carpenter, L.; Ceruti, S.; De Filippo, E.; Delagnes, E.; De Luca, S.; De Witte, H.; Druillole, F.; Duclos, B.; Favela, F.; Fritsch, A.; Giovinazzo, J.; Gueye, C.; Isobe, T.; Hellmuth, P.; Huss, C.; Lachacinski, B.; Laffoley, A. T.; Lebertre, G.; Legeard, L.; Lynch, W. G.; Marchi, T.; Martina, L.; Maugeais, C.; Mittig, W.; Nalpas, L.; Pagano, E. V.; Pancin, J.; Poleshchuk, O.; Pedroza, J. L.; Pibernat, J.; Primault, S.; Raabe, R.; Raine, B.; Rebii, A.; Renaud, M.; Roger, T.; Roussel-Chomaz, P.; Russotto, P.; Saccà, G.; Saillant, F.; Sizun, P.; Suzuki, D.; Swartz, J. A.; Tizon, A.; Usher, N.; Wittwer, G.; Yang, J. C.
2018-04-01
General Electronics for TPCs (GET) is a generic, reconfigurable and comprehensive electronics and data-acquisition system for nuclear physics instrumentation of up to 33792 channels. The system consists of a custom-designed ASIC for signal processing, front-end cards that each house 4 ASIC chips and digitize the data in parallel through 12-bit ADCs, concentration boards to read and process the digital data from up to 16 ASICs, a 3-level trigger and master clock module to trigger the system and synchronize the data, as well as all of the associated firmware, communication and data-acquisition software. An overview of the system including its specifications and measured performances are presented.
VST project: distributed control system overview
NASA Astrophysics Data System (ADS)
Mancini, Dario; Mazzola, Germana; Molfese, C.; Schipani, Pietro; Brescia, Massimo; Marty, Laurent; Rossi, Emilio
2003-02-01
The VLT Survey Telescope (VST) is a co-operative program between the European Southern Observatory (ESO) and the INAF Capodimonte Astronomical Observatory (OAC), Naples, for the study, design, and realization of a 2.6-m wide-field optical imaging telescope to be operated at the Paranal Observatory, Chile. The telescope design, manufacturing and integration are responsibility of OAC. The VST has been specifically designed to carry out stand-alone observations in the UV to I spectral range and to supply target databases for the ESO Very Large Telescope (VLT). The control hardware is based on a large utilization of distributed embedded specialized controllers specifically designed, prototyped and manufactured by the Technology Working Group for VST project. The use of a field bus improves the whole system reliability in terms of high level flexibility, control speed and allow to reduce drastically the plant distribution in the instrument. The paper describes the philosophy and the architecture of the VST control HW with particular reference to the advantages of this distributed solution for the VST project.
Software for simulation of a computed tomography imaging spectrometer using optical design software
NASA Astrophysics Data System (ADS)
Spuhler, Peter T.; Willer, Mark R.; Volin, Curtis E.; Descour, Michael R.; Dereniak, Eustace L.
2000-11-01
Our Imaging Spectrometer Simulation Software known under the name Eikon should improve and speed up the design of a Computed Tomography Imaging Spectrometer (CTIS). Eikon uses existing raytracing software to simulate a virtual instrument. Eikon enables designers to virtually run through the design, calibration and data acquisition, saving significant cost and time when designing an instrument. We anticipate that Eikon simulations will improve future designs of CTIS by allowing engineers to explore more instrument options.
MARXS: A Modular Software to Ray-trace X-Ray Instrumentation
NASA Astrophysics Data System (ADS)
Günther, Hans Moritz; Frost, Jason; Theriault-Shay, Adam
2017-12-01
To obtain the best possible scientific result, astronomers must understand the properties of the available instrumentation well. This is important both when designing new instruments and when using existing instruments close to the limits of their specified capabilities or beyond. Ray-tracing is a technique for numerical simulations where the path of many light rays is followed through the system to understand how individual system components influence the observed properties, such as the shape of the point-spread-function. In instrument design, such simulations can be used to optimize the performance. For observations with existing instruments, this helps to discern instrumental artefacts from a true signal. Here, we describe MARXS, a new python package designed to simulate X-ray instruments on satellites and sounding rockets. MARXS uses probability tracking of photons and has polarimetric capabilities.
Qiu, Bing; Liu, Fei; Tang, Bensen; Deng, Biyong; Liu, Fang; Zhu, Weimin; Zhen, Dong; Xue, Mingyuan; Zhang, Mingjiao
2017-10-01
Patient-specific instrumentation (PSI) was designed to improve the accuracy of preoperative planning and postoperative prosthesis positioning in total knee arthroplasty (TKA). However, better understanding needs to be achieved due to the subtle nature of the PSI systems. In this study, 3D printing technique based on the image data of computed tomography (CT) has been utilized for optimal controlling of the surgical parameters. Two groups of TKA cases have been randomly selected as PSI group and control group with no significant difference of age and sex ( p > 0.05). The PSI group is treated with 3D printed cutting guides whereas the control group is treated with conventional instrumentation (CI). By evaluating the proximal osteotomy amount, distal osteotomy amount, valgus angle, external rotation angle, and tibial posterior slope angle of patients, it can be found that the preoperative quantitative assessment and intraoperative changes can be controlled with PSI whereas CI is relied on experience. In terms of postoperative parameters, such as hip-knee-ankle (HKA), frontal femoral component (FFC), frontal tibial component (FTC), and lateral tibial component (LTC) angles, there is a significant improvement in achieving the desired implant position ( p < 0.05). Assigned from the morphology of patients' knees, the PSI represents the convergence of congruent designs with current personalized treatment tools. The PSI can achieve less extremity alignment and greater accuracy of prosthesis implantation compared against control method, which indicates potential for optimal HKA, FFC, and FTC angles. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-03
... Specifications (STS) to define a new time limit for restoring inoperable RCS leakage detection instrumentation to... operability of the RCS leakage detection instrumentation. The CLIIP model SE will facilitate expedited... Operability Requirements and Actions for RCS Leakage Instrumentation'' AGENCY: U.S. Nuclear Regulatory...
ASHI: An All Sky Heliospheric Imager for Viewing Thomson-Scattered Light
NASA Astrophysics Data System (ADS)
Buffington, A.; Jackson, B. V.; Yu, H. S.; Hick, P. P.; Bisi, M. M.
2017-12-01
We have developed, and are now making a detailed design for an All-Sky Heliospheric Imager (ASHI), to fly on future deep-space missions. ASHI's principal long-term objective is acquisition of a precision photometric map of the inner heliosphere as viewed from deep space. Photometers on the twin Helios spacecraft, the Solar Mass Ejection Imager (SMEI) upon the Coriolis satellite, and the Heliospheric Imagers (HIs) upon the Solar-TErrestrial RElations Observatory (STEREO) twin spacecraft, all indicate an optimum instrument design for visible-light Thomson-scattering observations. This design views a hemisphere of sky starting a few degrees from the Sun. Two imagers can cover almost all of the whole sky. A key photometric specification for ASHI is 0.1% differential photometry: this enables the three dimensional reconstruction of density starting from near the Sun and extending outward. SMEI analyses have demonstrated the success of this technique: when employed by ASHI, this will provide an order of magnitude better resolution in 3-D density over time. We augment this analysis to include velocity, and these imagers deployed in deep space can thus provide high-resolution comparisons both of direct in-situ density and velocity measurements to remote observations of solar wind structures. In practice we find that the 3-D velocity determinations provide the best tomographic timing depiction of heliospheric structures. We discuss the simple concept behind this, and present recent progress in the instrument design, and its expected performance specifications. A preliminary balloon flight of an ASHI prototype is planned to take place next Summer.
Solid electrolyte oxygen regeneration system
NASA Technical Reports Server (NTRS)
Shumar, J. W.; See, G. G.; Schubert, F. H.; Powell, J. D.
1976-01-01
A program to design, develop, fabricate and assemble a one-man, self-contained, solid electrolyte oxygen regeneration system (SX-1) incorporating solid electrolyte electrolyzer drums was completed. The SX-1 is a preprototype engineering model designed to produce 0.952 kg (2.1 lb)/day of breathable oxygen (O2) from the electrolysis of metabolic carbon dioxide (CO2) and water vapor. The CO2 supply rate was established based on the metabolic CO2 generation rate for one man of 0.998 kg (2.2 lb)/day. The water supply rate (0.254 kg (0.56 lb)/day) was designed to be sufficient to make up the difference between the 0.952 kg (2.1 lb)/day O2 generation specification and the O2 available through CO2 electrolysis, 0.726 kg (1.6 lb)/day. The SX-1 was successfully designed, fabricated and assembled. Design verification tests (DVT) or the CO Disproportionators, H2 separators, control instrumentation, monitor instrumentation, water feed mechanism were successfully completed. The erratic occurrence of electrolyzer drum leakage prevented the completion of the CO2 electrolyzer module and water electrolyzer module DVT's and also prevented the performance of SX-1 integrated testing. Further development work is required to improve the solid electrolyte cell high temperature seals.
Ergonomics of medical lasers: operator's viewpoint
NASA Astrophysics Data System (ADS)
Rogers, David W.; Jobes, H. M.; Hinshaw, J. Raymond; Lanzafame, Raymond J.
1992-06-01
Lasers are instruments that may enhance the surgeons ability to perform surgery. Many medical lasers sit unused. Lack of use is associated with 'user unfriendliness'. Nurses and surgeons often cite factors such as complexity, location, and types of controls, and content of displays. Other factors such as culture-ethnology and its relationship to command words and symbols, affect understandability of controls, displays and user friendliness. Laser designers and engineers must analyze the interaction between laser users and products. They must fully understand the training limitations and unique working environments (surgical specialty) of operators. Laser design and operation must coincide with specific needs and expectations of the nurses and physicians. Poor design and engineering compromises results in non use of expensive instrumentation, products which are ineffective for clinical use, and could potentially increase the risk of possible injury to patients and staff. This paper discusses the design and operation of medical laser systems. The advantages and disadvantages of several laser systems will be presented. User interfaces for controls - color, function, touch activation, labels and size, sound cues, laser activation, type and amount of feedback information during operation; design of storage for accessories, and need for features such as pulsing, and milliwatts will be discussed. We will present what we consider to be an ideal laser system.
NASA Astrophysics Data System (ADS)
Cataldo, G.; Barrentine, E. M.; Bulcha, B. T.; Ehsan, N.; Hess, L. A.; Noroozian, O.; Stevenson, T. R.; U-Yen, K.; Wollack, E. J.; Moseley, S. H.
2018-04-01
Micro-Spec (µ-Spec) is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ˜ 10-cm^2 chip through the use of superconducting microstrip transmission lines on a single-crystal silicon substrate. A second-generation µ-Spec is being designed to operate with a spectral resolution of 512 in the submillimeter (500-1000 µm, 300-600 GHz) wavelength range, a band of interest for several spectroscopic applications in astrophysics. High-altitude balloon missions would provide the first test bed to demonstrate the µ-Spec technology in a space-like environment and would be an economically viable venue for multiple observation campaigns. This work reports on the current status of the instrument design and will provide a brief overview of each instrument subsystem. Particular emphasis will be given to the design of the spectrometer's two-dimensional diffractive region, through which the light of different wavelengths is focused on the detectors along the focal plane. An optimization process is employed to generate geometrical configurations of the diffractive region that satisfy specific requirements on spectrometer size, operating spectral range, and performance. An optical design optimized for balloon missions will be presented in terms of geometric layout, spectral purity, and efficiency.
NASA Technical Reports Server (NTRS)
Hansen, Patricia A.; Hughes, David W.; Hedgeland, Randy J.; Chivatero, Craig J.; Studer, Robert J.; Kostos, Peter J.
1994-01-01
The Scientific Instrument Protective Enclosures were designed for the Hubble Space Telescope Servicing Missions to provide a beginning environment to a Scientific Instrument during ground and on orbit activities. The Scientific Instruments required very stringent surface cleanliness and molecular outgassing levels to maintain ultraviolet performance. Data from the First Servicing Mission verified that both the Scientific Instruments and Scientific Instrument Protective Enclosures met surface cleanliness level requirements during ground and on-orbit activities.
The Assessment Journey: Defining and Refining Instrument Dilemmas
ERIC Educational Resources Information Center
Gallo, Ann Marie; Carr, Michael T.; Gallo, Joseph A.
2010-01-01
Designing and implementing assessment instruments are ongoing challenges for physical educators. The initial design phase includes asking the question, "What do I want the students to know and/or be able to do?" Seemingly, the question is direct and should lead to a concrete answer. In addition to designing assessment instruments, one of the most…
Life Events and Academic Performance: Instrument Design.
ERIC Educational Resources Information Center
Burke, Janet; Cartwright, Noel
In April 1987, a pilot study was undertaken to develop an instrument designed to assess the effects of life events on undergraduate students' academic performance. Focus was on the design and construction of the instrument--the Life Events and Academic Performance Questionnaire (LEAPQ). Subjects were 75 male and 75 female undergraduates at a large…
De Maesschalck, Stephanie; Willems, Sara; De Maeseneer, Jan; Deveugele, Myriam
2010-04-01
The growing diversity of patient populations challenges health care providers. Physicians' attitudes and perceptions toward cultural diversity in health care could be partly contributing to difficulties in communication between physicians and ethnic minority patients. To evaluate these attitudes and perceptions, an instrument was developed and validated. A preliminary version of the instrument was developed through literature research and expert consultation and completed by 112 family physicians. Factor analysis was performed and reliability and construct validity tested. The instrument revealed three factors that were interpreted as: (1) physicians' task perception and ideas on cultural differences in health and health care, (2) physicians' attitudes toward physician-patient communication with minority patients, and (3) physicians' perception of minority patients' needs in communication. Moderate but significant correlations were found between factors of the EMP-3 and practice organization, practice location, and physicians' gender. Several factors of the Jefferson Empathy Scale, the Patient Practitioner Orientation Scale, and the Health Beliefs and Attitude Scale related to the first two factors of the EMP-3. This instrument, designed specifically to measure physicians' attitudes toward cultural diversity, showed moderate validity and reliability results. Further adaptations and evaluation could be useful.
Earth Observing Scanning Polarimeter (EOSP), phase B
NASA Technical Reports Server (NTRS)
1990-01-01
Evaluations performed during a Phase B study directed towards defining an optimal design for the Earth Observing Scanning Polarimeter (EOSP) instrument is summarized. An overview of the experiment approach is included which provides a summary of the scientific objectives, the background of the measurement approach, and the measurement method. In the instrumentation section, details of the design are discussed starting with the key instrument features required to accomplish the scientific objectives and a system characterization in terms of the Stokes vector/Mueller matrix formalism. This is followed by a detailing of the instrument design concept, the design of the individual elements of the system, the predicted performance, and a summary of appropriate instrument testing and calibration. The selected design makes use of key features of predecessor polarimeters and is fully compatible with the Earth Observing System spacecraft requirements.