2013-01-01
Background Measuring team factors in evaluations of Continuous Quality Improvement (CQI) may provide important information for enhancing CQI processes and outcomes; however, the large number of potentially relevant factors and associated measurement instruments makes inclusion of such measures challenging. This review aims to provide guidance on the selection of instruments for measuring team-level factors by systematically collating, categorizing, and reviewing quantitative self-report instruments. Methods Data sources: We searched MEDLINE, PsycINFO, and Health and Psychosocial Instruments; reference lists of systematic reviews; and citations and references of the main report of instruments. Study selection: To determine the scope of the review, we developed and used a conceptual framework designed to capture factors relevant to evaluating CQI in primary care (the InQuIRe framework). We included papers reporting development or use of an instrument measuring factors relevant to teamwork. Data extracted included instrument purpose; theoretical basis, constructs measured and definitions; development methods and assessment of measurement properties. Analysis and synthesis: We used qualitative analysis of instrument content and our initial framework to develop a taxonomy for summarizing and comparing instruments. Instrument content was categorized using the taxonomy, illustrating coverage of the InQuIRe framework. Methods of development and evidence of measurement properties were reviewed for instruments with potential for use in primary care. Results We identified 192 potentially relevant instruments, 170 of which were analyzed to develop the taxonomy. Eighty-one instruments measured constructs relevant to CQI teams in primary care, with content covering teamwork context (45 instruments measured enabling conditions or attitudes to teamwork), team process (57 instruments measured teamwork behaviors), and team outcomes (59 instruments measured perceptions of the team or its effectiveness). Forty instruments were included for full review, many with a strong theoretical basis. Evidence supporting measurement properties was limited. Conclusions Existing instruments cover many of the factors hypothesized to contribute to QI success. With further testing, use of these instruments measuring team factors in evaluations could aid our understanding of the influence of teamwork on CQI outcomes. Greater consistency in the factors measured and choice of measurement instruments is required to enable synthesis of findings for informing policy and practice. PMID:23410500
Mokkink, Lidwine B; Prinsen, Cecilia A C; Bouter, Lex M; Vet, Henrica C W de; Terwee, Caroline B
2016-01-19
COSMIN (COnsensus-based Standards for the selection of health Measurement INstruments) is an initiative of an international multidisciplinary team of researchers who aim to improve the selection of outcome measurement instruments both in research and in clinical practice by developing tools for selecting the most appropriate available instrument. In this paper these tools are described, i.e. the COSMIN taxonomy and definition of measurement properties; the COSMIN checklist to evaluate the methodological quality of studies on measurement properties; a search filter for finding studies on measurement properties; a protocol for systematic reviews of outcome measurement instruments; a database of systematic reviews of outcome measurement instruments; and a guideline for selecting outcome measurement instruments for Core Outcome Sets in clinical trials. Currently, we are updating the COSMIN checklist, particularly the standards for content validity studies. Also new standards for studies using Item Response Theory methods will be developed. Additionally, in the future we want to develop standards for studies on the quality of non-patient reported outcome measures, such as clinician-reported outcomes and performance-based outcomes. In summary, we plea for more standardization in the use of outcome measurement instruments, for conducting high quality systematic reviews on measurement instruments in which the best available outcome measurement instrument is recommended, and for stopping the use of poor outcome measurement instruments.
Mokkink, Lidwine B.; Prinsen, Cecilia A. C.; Bouter, Lex M.; de Vet, Henrica C. W.; Terwee, Caroline B.
2016-01-01
Background: COSMIN (COnsensus-based Standards for the selection of health Measurement INstruments) is an initiative of an international multidisciplinary team of researchers who aim to improve the selection of outcome measurement instruments both in research and in clinical practice by developing tools for selecting the most appropriate available instrument. Method: In this paper these tools are described, i.e. the COSMIN taxonomy and definition of measurement properties; the COSMIN checklist to evaluate the methodological quality of studies on measurement properties; a search filter for finding studies on measurement properties; a protocol for systematic reviews of outcome measurement instruments; a database of systematic reviews of outcome measurement instruments; and a guideline for selecting outcome measurement instruments for Core Outcome Sets in clinical trials. Currently, we are updating the COSMIN checklist, particularly the standards for content validity studies. Also new standards for studies using Item Response Theory methods will be developed. Additionally, in the future we want to develop standards for studies on the quality of non-patient reported outcome measures, such as clinician-reported outcomes and performance-based outcomes. Conclusions: In summary, we plea for more standardization in the use of outcome measurement instruments, for conducting high quality systematic reviews on measurement instruments in which the best available outcome measurement instrument is recommended, and for stopping the use of poor outcome measurement instruments. PMID:26786084
Field evaluation of boat-mounted acoustic Doppler instruments used to measure streamflow
Mueller, D.S.; ,
2003-01-01
The use of instruments based on the Doppler principle for measuring water velocity and computing discharge is common within the U.S. Geological Survey (USGS). The instruments and software have changed appreciably during the last 5 years; therefore, the USGS has begun field validation of the instruments used to make discharge measurements from a moving boat. Instruments manufactured by SonTek/YSI and RD Instruments, Inc. were used to collect discharge data at five different sites. One or more traditional discharge measurements were made using a Price AA current meter and standard USGS procedures concurrent with the acoustic instruments at each site. Discharges measured with the acoustic instruments were compared with discharges measured with Price AA current meters and the USGS stage-discharge rating for each site. The mean discharges measured by each acoustic instrument were within 5 percent of the Price AA-based measurement and (or) discharge from the stage-discharge rating.
Matarese, Maria; Lommi, Marzia; De Marinis, Maria Grazia
2017-06-01
The aims of this study were as follows: to identify instruments developed to assess self-care in healthy adults; to determine the theory on which they were based; their validity and reliability properties and to synthesize the evidence on their measurement properties. Many instruments have been developed to assess self-care in many different populations and conditions. Clinicians and researchers should select the most appropriate self-care instrument based on the knowledge of their measurement properties. Systematic review of measurement instruments according to the protocol recommended by the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. PubMed, Embase, PsycINFO, Scopus and CINAHL databases were searched from inception to December 2015. Studies testing measurement properties of self-report instruments assessing self-care in healthy adults, published in the English language and in peer review journals were selected. Two reviewers independently appraised the methodological quality of the studies with the COSMIN checklist and the quality of results using specific quality criteria. Twenty-six articles were included in the review testing the measurement properties of nine instruments. Seven instruments were based on Orem's Self-care theory. Not all the measurement properties were evaluated for the identified instruments. No self-care instrument showed strong evidence supporting the evaluated measurement properties. Despite the development of several instruments to assess self-care in the adult population, no instrument can be fully recommended to clinical nurses and researchers. Further studies of high methodological quality are needed to confirm the measurement properties of these instruments. © 2016 John Wiley & Sons Ltd.
21 CFR 886.1460 - Stereopsis measuring instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stereopsis measuring instrument. 886.1460 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1460 Stereopsis measuring instrument. (a) Identification. A stereopsis measuring instrument is a device intended to measure depth...
21 CFR 886.1425 - Lens measuring instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lens measuring instrument. 886.1425 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1425 Lens measuring instrument. (a) Identification. A lens measuring instrument is an AC-powered device intended to measure the power of lenses...
40 CFR 1066.130 - Measurement instrument calibrations and verifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Measurement instrument calibrations... (CONTINUED) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Equipment, Measurement Instruments, Fuel, and Analytical Gas Specifications § 1066.130 Measurement instrument calibrations and verifications. The...
Aspden, Trefor; Bradshaw, Siobhan A; Playford, E Diane; Riazi, Afsane
2014-09-01
the aims of this review were (i) to identify quality-of-life (QoL) measures which have had their measurement properties validated in people residing in care homes or nursing homes, and to critically compare and summarise these instruments and (ii) to make recommendations for measurement instruments. bibliographic databases PsycINFO, PubMed, Cochrane, CINAHL and Embase were searched for articles evaluating measurement properties of QoL instruments in people residing in care homes. Methodological quality of studies was assessed using the consensus-based standards for the selection of health measurement instruments checklist. Measurement properties of instruments were appraised using a systematic checklist. the search strategy resulted in 3252 unique citations, of which 15 articles were included in this review. These articles assessed 13 instruments, 8 of which were dementia or Alzheimer specific instruments. The QUALIDEM, a dementia-specific observational instrument, had the widest array of information available on its measurement properties, which were mostly satisfactory. Most measurement instruments lacked information on hypotheses testing and content validity. Information on responsiveness and measurement error was not available for any instrument. for people with dementia living in care homes, the QUALIDEM is recommended for measuring QoL. For residents without dementia, we recommend Kane et al.'s Psychosocial Quality of Life Domains questionnaire. Studies of higher methodological quality, assessing a wider range of measurement properties are needed to allow a more fully informed choice of QoL instrument. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
2012-01-01
Background Continuous quality improvement (CQI) methods are widely used in healthcare; however, the effectiveness of the methods is variable, and evidence about the extent to which contextual and other factors modify effects is limited. Investigating the relationship between these factors and CQI outcomes poses challenges for those evaluating CQI, among the most complex of which relate to the measurement of modifying factors. We aimed to provide guidance to support the selection of measurement instruments by systematically collating, categorising, and reviewing quantitative self-report instruments. Methods Data sources: We searched MEDLINE, PsycINFO, and Health and Psychosocial Instruments, reference lists of systematic reviews, and citations and references of the main report of instruments. Study selection: The scope of the review was determined by a conceptual framework developed to capture factors relevant to evaluating CQI in primary care (the InQuIRe framework). Papers reporting development or use of an instrument measuring a construct encompassed by the framework were included. Data extracted included instrument purpose; theoretical basis, constructs measured and definitions; development methods and assessment of measurement properties. Analysis and synthesis: We used qualitative analysis of instrument content and our initial framework to develop a taxonomy for summarising and comparing instruments. Instrument content was categorised using the taxonomy, illustrating coverage of the InQuIRe framework. Methods of development and evidence of measurement properties were reviewed for instruments with potential for use in primary care. Results We identified 186 potentially relevant instruments, 152 of which were analysed to develop the taxonomy. Eighty-four instruments measured constructs relevant to primary care, with content measuring CQI implementation and use (19 instruments), organizational context (51 instruments), and individual factors (21 instruments). Forty-one instruments were included for full review. Development methods were often pragmatic, rather than systematic and theory-based, and evidence supporting measurement properties was limited. Conclusions Many instruments are available for evaluating CQI, but most require further use and testing to establish their measurement properties. Further development and use of these measures in evaluations should increase the contribution made by individual studies to our understanding of CQI and enhance our ability to synthesise evidence for informing policy and practice. PMID:23241168
Instrumentation for detailed bridge-scour measurements
Landers, Mark N.; Mueller, David S.; Trent, Roy E.; ,
1993-01-01
A portable instrumentation system is being developed to obtain channel bathymetry during floods for detailed bridge-scour measurements. Portable scour measuring systems have four components: sounding instrument, horizontal positioning instrument, deployment mechanisms, and data storage device. The sounding instrument will be a digital fathometer. Horizontal position will be measured using a range-azimuth based hydrographic survey system. The deployment mechanism designed for this system is a remote-controlled boat using a small waterplane area, twin-hull design. An on-board computer and radio will monitor the vessel instrumentation, record measured data, and telemeter data to shore.
Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.
Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm
2016-12-01
Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research. A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones. This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties. We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care integration (33%) and patient-centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross-cultural validity (14%) were less commonly reported. We found <50% of the validation studies to be of good or excellent quality for any of the measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less-studied constructs and domains to become part of newly developed instruments. © 2016 Milbank Memorial Fund.
Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties
BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM
2016-01-01
Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research.A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones.This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties.We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Context Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Methods Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. Findings From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care integration (33%) and patient‐centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross‐cultural validity (14%) were less commonly reported. We found <50% of the validation studies to be of good or excellent quality for any of the measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Conclusions Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less‐studied constructs and domains to become part of newly developed instruments. PMID:27995711
Lima, Elaine; Teixeira-Salmela, Luci F; Simões, Luan; Guerra, Ana C C; Lemos, Andrea
2016-03-15
While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.
Lima, Elaine; Teixeira-Salmela, Luci F.; Simões, Luan; Guerra, Ana C. C.; Lemos, Andrea
2016-01-01
Background While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. Objective To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Method Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. Results A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. Conclusion The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed. PMID:26982452
Frasure, Jamey
2008-01-01
This paper is a report of a systematic review describing instruments used to measure nurses' attitudes towards research utilization. Researchers need to have the tools to measure nurses' attitudes. However, limited literature critically analyses instruments and the concepts that comprise nurses' attitudes towards research utilization. A search of the literature from 1982 to 2007 was performed using the Cumulative Index to Nursing and Allied Health Literature, Health and Psychosocial Instruments, PubMed and MEDLINE data bases. The search terms were nursing research, research utilization, instruments, and nurses' attitudes. A total of 186 sources were identified, of which 25 were reviewed. Fourteen instruments met the criteria for in-depth critical analysis of psychometric properties and concepts, and were included in the final review. Each instrument item was judged to be relevant to direct, indirect, persuasive and overall research utilization as defined by Estabrooks. Instruments were arranged from the strongest to the weakest reliability of the subscales to determine the instrument with the strongest psychometric properties. Indirect and overall research utilization was measured by all of the instruments. Ten instruments measured direct research utilization and nine instruments measured persuasive research utilization. The Research Utilization in Nursing Survey by Estabrooks, as adapted by Kenny, was an instrument with strong psychometric properties measuring all four concepts of nurses' attitudes towards using and participating in research and was clinically feasible. Many published instruments are available for use by nurse researchers to measure nurses' attitude towards research utilization, but only one has been subjected to rigorous testing: the Research Utilization in Nursing Survey by Estabrooks.
Measures of Cultural Competence in Nurses: An Integrative Review
2013-01-01
Background. There is limited literature available identifying and describing the instruments that measure cultural competence in nursing students and nursing professionals. Design. An integrative review was undertaken to identify the characteristics common to these instruments, examine their psychometric properties, and identify the concepts these instruments are designed to measure. Method. There were eleven instruments identified that measure cultural competence in nursing. Of these eleven instruments, four had been thoroughly tested in either initial development or in subsequent testing, with developers providing extensive details of the testing. Results. The current literature identifies that the instruments to assess cultural competence in nurses and nursing students are self-administered and based on individuals' perceptions. The instruments are commonly utilized to test the effectiveness of educational programs designed to increase cultural competence. Conclusions. The reviewed instruments measure nurses' self-perceptions or self-reported level of cultural competence but offer no objective measure of culturally competent care from a patient's perspective which can be problematic. Comparison of instruments reveals that they are based on a variety of conceptual frameworks and that multiple factors should be considered when deciding which instrument to use. PMID:23818818
Richardson, Jeff; Khan, Munir A; Iezzi, Angelo; Maxwell, Aimee
2015-04-01
Cost utility analysis permits the comparison of disparate health services by measuring outcomes in comparable units, namely, quality-adjusted life-years, which equal life-years times the utility of the health state. However, comparability is compromised when different utility instruments predict different utilities for the same health state. The present paper measures the extent of, and reason for, differences between the utilities predicted by the EQ-5D-5L, SF-6D, HUI 3, 15D, QWB, and AQoL-8D. Data were obtained from patients in seven disease areas and members of the healthy public in six countries. Differences between public and patient utilities were estimated using each of the instruments. To explain discrepancies between the estimates, the measurement scales and content of the instruments were compared. The sensitivity of instruments to independently measured health dimensions was measured in pairwise comparisons of all combinations of the instruments. The difference between public and patient utilities varied with the choice of instrument by more than 50% for every disease group and in four of the seven groups by more than 100%. Discrepancies were associated with differences in both the instrument content and their measurement scales. Pairwise comparisons of instruments found that variation in the sensitivity to physical and psychosocial dimensions of health closely reflected the items in the instrument's descriptive systems. Results indicate that instruments measure related but different constructs. They imply that commonly used instruments systematically discriminate against some classes of services, most notably mental health services. Differences in the instrument scales imply the need for transformations between the instruments to increase the comparability of measurement. © The Author(s) 2014.
Darzins, Susan W; Imms, Christine; Di Stefano, Marilyn
2017-05-01
To explore the operationalization of activity and participation-related measurement constructs through comparison of item phrasing, item response categories and scoring (scale properties) for two separate instruments targeting activities of daily living. Personal Care Participation Assessment and Resource Tool (PC-PART) item content was linked to ICF categories using established linking rules. Previously reported ICF-linked FIM content categories and ICF-linked PC-PART content categories were compared to identify common ICF categories between the instruments. Scale properties of both instruments were compared using a patient scenario to explore the instruments' separate measurement constructs. The PC-PART and FIM shared 15 of the 53 level two ICF-linked categories identified across both instruments. Examination of the instruments' scale properties for items with overlapping ICF content, and exploration through a patient scenario, provided supportive evidence that the instruments measure different constructs. While the PC-PART and FIM share common ICF-linked content, they measure separate constructs. Measurement construct was influenced by the instruments' scale properties. The FIM was observed to measure activity limitations and the PC-PART measured participation restrictions. Scrutiny of instruments' scale properties in addition to item content is critical in the operationalization of activity and participation-related measurement constructs. Implications for Rehabilitation When selecting outcome measures for use in rehabilitation it is necessary to examine both the content of the instruments' items and item phrasing, response categories and scoring, to clarify the construct being measured. Measurement of activity limitations as well as participation restrictions in activities of daily living required for community life provides a more comprehensive measurement of rehabilitation outcomes than measurement of either construct alone. To measure the effects of interventions used in rehabilitation, it is necessary to select measures with relevant content and scale properties that enable evaluation of change in the constructs that are expected to change, as a result of the rehabilitation intervention.
Goujon, Nicolas; Devine, Alexandra; Baker, Sally M; Sprunt, Beth; Edmonds, Tanya J; Booth, Jennifer K; Keeffe, Jill E
2014-01-01
A review of existing measurement instruments was conducted to examine their suitability to measure disability prevalence and assess quality of life, protection of disability rights and community participation by people with disabilities, specifically within the context of development programs in low and middle-income countries. From a search of PubMed and the grey literature, potentially relevant measurement instruments were identified and examined for their content and psychometric properties, where possible. Criteria for inclusion were: based on the WHO's International Classification of Functioning Disability and Health (ICF), used quantitative methods, suitable for population-based studies of disability inclusive development in English and published after 1990. Characteristics of existing instruments were analysed according to components of the ICF and quality of life domains. Ten instruments were identified and reviewed according to the criteria listed above. Each version of instruments was analysed separately. Only three instruments included a component on quality of life. Domains from the ICF that were addressed by some but not all instruments included the environment, technology and communication. The measurement instruments reviewed covered the range of elements required to measure disability-inclusion within development contexts. However no single measurement instrument has the capacity to measure both disability prevalence and changes in quality of life according to contemporary disability paradigms. The review of measurement instruments supports the need for developing an instrument specifically intended to measure disability inclusive practice within development programs. Implications for Rehabilitation Surveys and tools are needed to plan disability inclusive development. Existing measurement tools to determine prevalence of disability, wellbeing, rights and access to the community were reviewed. No single validated tool exists for population-based studies, uses quantitative methods and the components of the ICF to measure prevalence of disability, well-being of people with disability and their access to their communities. A measurement tool that reflects the UNCRPD and addresses all components of the ICF is needed to assist in disability inclusive development, especially in low and mid resource countries.
[Instruments for quantitative methods of nursing research].
Vellone, E
2000-01-01
Instruments for quantitative nursing research are a mean to objectify and measure a variable or a phenomenon in the scientific research. There are direct instruments to measure concrete variables and indirect instruments to measure abstract concepts (Burns, Grove, 1997). Indirect instruments measure the attributes by which a concept is made of. Furthermore, there are instruments for physiologic variables (e.g. for the weight), observational instruments (Check-lists e Rating Scales), interviews, questionnaires, diaries and the scales (Check-lists, Rating Scales, Likert Scales, Semantic Differential Scales e Visual Anologue Scales). The choice to select an instrument or another one depends on the research question and design. Instruments research are very useful in research both to describe the variables and to see statistical significant relationships. Very carefully should be their use in the clinical practice for diagnostic assessment.
Prinsen, Cecilia A C; Vohra, Sunita; Rose, Michael R; Boers, Maarten; Tugwell, Peter; Clarke, Mike; Williamson, Paula R; Terwee, Caroline B
2016-09-13
In cooperation with the Core Outcome Measures in Effectiveness Trials (COMET) initiative, the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative aimed to develop a guideline on how to select outcome measurement instruments for outcomes (i.e., constructs or domains) included in a "Core Outcome Set" (COS). A COS is an agreed minimum set of outcomes that should be measured and reported in all clinical trials of a specific disease or trial population. Informed by a literature review to identify potentially relevant tasks on outcome measurement instrument selection, a Delphi study was performed among a panel of international experts, representing diverse stakeholders. In three consecutive rounds, panelists were asked to rate the importance of different tasks in the selection of outcome measurement instruments, to justify their choices, and to add other relevant tasks. Consensus was defined as being achieved when 70 % or more of the panelists agreed and when fewer than 15 % of the panelists disagreed. Of the 481 invited experts, 120 agreed to participate of whom 95 (79 %) completed the first Delphi questionnaire. We reached consensus on four main steps in the selection of outcome measurement instruments for COS: Step 1, conceptual considerations; Step 2, finding existing outcome measurement instruments, by means of a systematic review and/or a literature search; Step 3, quality assessment of outcome measurement instruments, by means of the evaluation of the measurement properties and feasibility aspects of outcome measurement instruments; and Step 4, generic recommendations on the selection of outcome measurement instruments for outcomes included in a COS (consensus ranged from 70 to 99 %). This study resulted in a consensus-based guideline on the methods for selecting outcome measurement instruments for outcomes included in a COS. This guideline can be used by COS developers in defining how to measure core outcomes.
Design and validation of instruments to measure knowledge.
Elliott, T E; Regal, R R; Elliott, B A; Renier, C M
2001-01-01
Measuring health care providers' learning after they have participated in educational interventions that use experimental designs requires valid, reliable, and practical instruments. A literature review was conducted. In addition, experience gained from designing and validating instruments for measuring the effect of an educational intervention informed this process. The eight main steps for designing, validating, and testing the reliability of instruments for measuring learning outcomes are presented. The key considerations and rationale for this process are discussed. Methods for critiquing and adapting existent instruments and creating new ones are offered. This study may help other investigators in developing valid, reliable, and practical instruments for measuring the outcomes of educational activities.
2007-03-01
CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): REFINEMENT AND VALIDATION OF A SURVEY MEASURE...States Government. AFIT/GIR/ENV/07-M7 CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): REFINEMENT AND VALIDATION OF A SURVEY MEASURE...UNLIMITED AFIT/GIR/ENV/07-M7 CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): REFINEMENT AND VALIDATION OF A SURVEY MEASURE Michael
International Instrumentation Symposium, 32nd, Seattle, WA, May 5-8, 1986, Proceedings
NASA Astrophysics Data System (ADS)
The conference presents papers on blast, shock, and vibration instrumentation; wind tunnel instrumentation and controls; electrooptic and fiber optic instrumentation; special test facilities; reentry vehicle testing; and nondestructive test and acoustic test instrumentation. Other topic include real time systems, flight test and avionics instrumentation, data aquisition and analysis systems, thermal measurements, and advances in measurement technology. Particular attention is given to an automated fringe counting laser interferometer for low frequency vibration measurements, dynamic pressure measurements in pneumatic lines, optically interfaced sensor system for aerospace applications, the picobalance for single microparticle measurements, ellipsometric film thickness, nanometer wear measurement by ultrathin surface layer activation, a rugged electronic scanner designed for turbine test, failure mechanism characterization of platinum alloy, and the thick film strain gage.
Contact angle measurement with a smartphone
NASA Astrophysics Data System (ADS)
Chen, H.; Muros-Cobos, Jesus L.; Amirfazli, A.
2018-03-01
In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.
Contact angle measurement with a smartphone.
Chen, H; Muros-Cobos, Jesus L; Amirfazli, A
2018-03-01
In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.
Agri-Environmental Policy Measures in Israel: The Potential of Using Market-Oriented Instruments
NASA Astrophysics Data System (ADS)
Amdur, Liron; Bertke, Elke; Freese, Jan; Marggraf, Rainer
2011-05-01
This paper examines the possibilities of developing agri-environmental policy measures in Israel, focusing on market-oriented instruments. A conceptual framework for developing agri-environmental policy measures is presented, first in very broad lines (mandatory regulations, economic instruments and advisory measures) and subsequently focusing on economic instruments, and specifically, on market-oriented ones. Two criteria of choice between the measures are suggested: their contribution to improving the effectiveness of the policy; and the feasibility of their implementation. This is the framework used for analyzing agri-environmental measures in Israel. Israel currently implements a mix of mandatory regulations, economic instruments and advisory measures to promote the agri-environment. The use of additional economic instruments may improve the effectiveness of the policy. When comparing the effectiveness of various economic measures, we found that the feasibility of implementation of market-oriented instruments is greater, due to the Israeli public's preference for strengthening market orientation in the agricultural sector. Four market-oriented instruments were practiced in a pilot project conducted in an Israeli rural area. We found that in this case study, the institutional feasibility and acceptance by stakeholders were the major parameters influencing the implementation of the market-oriented instruments, whereas the instruments' contribution to enhancing the ecological or economic effectiveness were hardly considered by the stakeholders as arguments in favor of their use.
Agri-environmental policy measures in Israel: the potential of using market-oriented instruments.
Amdur, Liron; Bertke, Elke; Freese, Jan; Marggraf, Rainer
2011-05-01
This paper examines the possibilities of developing agri-environmental policy measures in Israel, focusing on market-oriented instruments. A conceptual framework for developing agri-environmental policy measures is presented, first in very broad lines (mandatory regulations, economic instruments and advisory measures) and subsequently focusing on economic instruments, and specifically, on market-oriented ones. Two criteria of choice between the measures are suggested: their contribution to improving the effectiveness of the policy; and the feasibility of their implementation. This is the framework used for analyzing agri-environmental measures in Israel. Israel currently implements a mix of mandatory regulations, economic instruments and advisory measures to promote the agri-environment. The use of additional economic instruments may improve the effectiveness of the policy. When comparing the effectiveness of various economic measures, we found that the feasibility of implementation of market-oriented instruments is greater, due to the Israeli public's preference for strengthening market orientation in the agricultural sector. Four market-oriented instruments were practiced in a pilot project conducted in an Israeli rural area. We found that in this case study, the institutional feasibility and acceptance by stakeholders were the major parameters influencing the implementation of the market-oriented instruments, whereas the instruments' contribution to enhancing the ecological or economic effectiveness were hardly considered by the stakeholders as arguments in favor of their use.
Apfelbacher, Christian J; Heinl, Daniel; Prinsen, Cecilia A C; Deckert, Stefanie; Chalmers, Joanne; Ofenloch, Robert; Humphreys, Rosemary; Sach, Tracey; Chamlin, Sarah; Schmitt, Jochen
2015-04-16
Eczema is a common chronic or chronically relapsing skin disease that has a substantial impact on quality of life (QoL). By means of a consensus-based process, the Harmonising Outcome Measures in Eczema (HOME) initiative has identified QoL as one of the four core outcome domains to be assessed in all eczema trials (Allergy 67(9):1111-7, 2012). Various measurement instruments exist to measure QoL in adults with eczema, but there is a great variability in both content and quality (for example, reliability and validity) of the instruments used, and it is not always clear if the best instrument is being used. Therefore, the aim of the proposed research is a comprehensive systematic assessment of the measurement properties of the existing measurement instruments that were developed and/or validated for the measurement of patient-reported QoL in adults with eczema. This study is a systematic review of the measurement properties of patient-reported measures of QoL developed and/or validated for adults with eczema. Medline via PubMed and EMBASE will be searched using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing, or comparing measurement properties of QoL instruments for adult patients with eczema. Eligibility assessment and data abstraction will be performed independently by two reviewers. Evidence tables will be generated for study characteristics, instrument characteristics, measurement properties, and interpretability. The quality of the measurement properties will be assessed using predefined criteria. Methodological quality of studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis will be undertaken if more than one study has investigated a particular measurement property. The proposed systematic review will produce a comprehensive assessment of measurement properties of existing QoL instruments in adult patients with eczema. We aim to identify one best currently available instrument to measure QoL in eczema patients. PROSPERO CRD42015017138.
Instruments measuring spirituality in clinical research: a systematic review.
Monod, Stéfanie; Brennan, Mark; Rochat, Etienne; Martin, Estelle; Rochat, Stéphane; Büla, Christophe J
2011-11-01
Numerous instruments have been developed to assess spirituality and measure its association with health outcomes. This study's aims were to identify instruments used in clinical research that measure spirituality; to propose a classification of these instruments; and to identify those instruments that could provide information on the need for spiritual intervention. A systematic literature search in MEDLINE, CINHAL, PsycINFO, ATLA, and EMBASE databases, using the terms "spirituality" and "adult$," and limited to journal articles was performed to identify clinical studies that used a spiritual assessment instrument. For each instrument identified, measured constructs, intended goals, and data on psychometric properties were retrieved. A conceptual and a functional classification of instruments were developed. Thirty-five instruments were retrieved and classified into measures of general spirituality (N = 22), spiritual well-being (N = 5), spiritual coping (N = 4), and spiritual needs (N = 4) according to the conceptual classification. Instruments most frequently used in clinical research were the FACIT-Sp and the Spiritual Well-Being Scale. Data on psychometric properties were mostly limited to content validity and inter-item reliability. According to the functional classification, 16 instruments were identified that included at least one item measuring a current spiritual state, but only three of those appeared suitable to address the need for spiritual intervention. Instruments identified in this systematic review assess multiple dimensions of spirituality, and the proposed classifications should help clinical researchers interested in investigating the complex relationship between spirituality and health. Findings underscore the scarcity of instruments specifically designed to measure a patient's current spiritual state. Moreover, the relatively limited data available on psychometric properties of these instruments highlight the need for additional research to determine whether they are suitable in identifying the need for spiritual interventions.
Heinl, D; Prinsen, C A C; Sach, T; Drucker, A M; Ofenloch, R; Flohr, C; Apfelbacher, C
2017-04-01
Quality of life (QoL) is one of the core outcome domains identified by the Harmonising Outcome Measures for Eczema (HOME) initiative to be assessed in every eczema trial. There is uncertainty about the most appropriate QoL instrument to measure this domain in infants, children and adolescents. To systematically evaluate the measurement properties of existing measurement instruments developed and/or validated for the measurement of QoL in infants, children and adolescents with eczema. A systematic literature search in PubMed and Embase, complemented by a thorough hand search of reference lists, retrieved studies on measurement properties of eczema QoL instruments for infants, children and adolescents. For all eligible studies, we judged the adequacy of the measurement properties and the methodological study quality with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Results from different studies were summarized in a best-evidence synthesis and formed the basis to assign four degrees of recommendation. Seventeen articles, three of which were found by hand search, were included. These 17 articles reported on 24 instruments. No instrument can be recommended for use in all eczema trials because none fulfilled all required adequacy criteria. With adequate internal consistency, reliability and hypothesis testing, the U.S. version of the Childhood Atopic Dermatitis Impact Scale (CADIS), a proxy-reported instrument, has the potential to be recommended depending on the results of further validation studies. All other instruments, including all self-reported ones, lacked significant validation data. Currently, no QoL instrument for infants, children and adolescents with eczema can be highly recommended. Future validation research should primarily focus on the CADIS, but also attempt to broaden the evidence base for the validity of self-reported instruments. © 2016 British Association of Dermatologists.
Abma, Femke I; van der Klink, Jac J L; Terwee, Caroline B; Amick, Benjamin C; Bültmann, Ute
2012-01-01
During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in occupational health practice and research, the measurement properties (eg, reliability, validity, responsiveness) must be evaluated. The objective of this study is to appraise critically and compare the measurement properties of self-reported health-related work-functioning instruments among workers with CMD. A systematic review was performed searching three electronic databases. Papers were included that: (i) mainly focused on the development and/or evaluation of the measurement properties of a self-reported health-related work-functioning instrument; (ii) were conducted in a CMD population; and (iii) were fulltext original papers. Quality appraisal was performed using the consensus-based standards for the selection of health status measurement instruments (COSMIN) checklist. Five papers evaluating measurement properties of five self-reported health-related work-functioning instruments in CMD populations were included. There is little evidence available for the measurement properties of the identified instruments in this population, mainly due to low methodological quality of the included studies. The available evidence on measurement properties is based on studies of poor-to-fair methodological quality. Information on a number of measurement properties, such as measurement error, content validity, and cross-cultural validity is still lacking. Therefore, no evidence-based decisions and recommendations can be made for the use of health-related work functioning instruments. Studies of high methodological quality are needed to properly assess the existing instruments' measurement properties.
A critical appraisal of instruments to measure outcomes of interprofessional education.
Oates, Matthew; Davidson, Megan
2015-04-01
Interprofessional education (IPE) is believed to prepare health professional graduates for successful collaborative practice. A range of instruments have been developed to measure the outcomes of IPE. An understanding of the psychometric properties of these instruments is important if they are to be used to measure the effectiveness of IPE. This review set out to identify instruments available to measure outcomes of IPE and collaborative practice in pre-qualification health professional students and to critically appraise the psychometric properties of validity, responsiveness and reliability against contemporary standards for instrument design. Instruments were selected from a pool of extant instruments and subjected to critical appraisal to determine whether they satisfied inclusion criteria. The qualitative and psychometric attributes of the included instruments were appraised using a checklist developed for this review. Nine instruments were critically appraised, including the widely adopted Readiness for Interprofessional Learning Scale (RIPLS) and the Interdisciplinary Education Perception Scale (IEPS). Validity evidence for instruments was predominantly based on test content and internal structure. Ceiling effects and lack of scale width contribute to the inability of some instruments to detect change in variables of interest. Limited reliability data were reported for two instruments. Scale development and scoring protocols were generally reported by instrument developers, but the inconsistent application of scoring protocols for some instruments was apparent. A number of instruments have been developed to measure outcomes of IPE in pre-qualification health professional students. Based on reported validity evidence and reliability data, the psychometric integrity of these instruments is limited. The theoretical test construction paradigm on which instruments have been developed may be contributing to the failure of some instruments to detect change in variables of interest following an IPE intervention. These limitations should be considered in any future research on instrument design. © 2015 John Wiley & Sons Ltd.
Magasi, Susan; Harniss, Mark; Heinemann, Allen W
2018-01-01
Principles of fairness in testing require that all test takers, including people with disabilities, have an equal opportunity to demonstrate their capacity on the construct being measured. Measurement design features and assessment protocols can pose barriers for people with disabilities. Fairness in testing is a fundamental validity issue at all phases in the design, administration, and interpretation of measurement instruments in clinical practice and research. There is limited guidance for instrument developers on how to develop and evaluate the accessibility and usability of measurement instruments. This article describes a 6-stage iterative process for developing accessible computer-administered measurement instruments grounded in the procedures implemented across several major measurement initiatives. A key component of this process is interdisciplinary teams of accessibility experts, content and measurement experts, information technology experts, and people with disabilities working together to ensure that measurement instruments are accessible and usable by a wide range of users. The development of accessible measurement instruments is not only an ethical requirement, it also ensures better science by minimizing measurement bias, missing data, and attrition due to mismatches between the target population and test administration platform and protocols. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Instrument development and the measurement of unitary constructs.
Carboni, J T
1992-01-01
This article initiates needed dialogue on the development of instruments to measure unitary constructs. The concept of measurement is explored and current measurement in Rogerian research is considered in light of the issues raised in the discussion. The human field - environmental field relationship is presented as the clinical practice area serving as the basis for the development of a unitary instrument that purports to measure field pattern. The instrument entitled Mutual Exploration of the Healing Human Field - Environmental Field Relationship is offered as a beginning effort in constructing an instrument that measures a unitary phenomenon. Rogerian scholars are provided with the challenge to continue the debate regarding the whole field of measurement and the development of unitary tools.
Corporate Entrepreneurship Assessment Instrument (CEAI): Systematic Validation of a Measure
2006-03-01
CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): SYSTEMATIC VALIDATION OF A MEASURE THESIS...the United States Government. AFIT/GIR/ENV/06M-05 CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): SYSTEMATIC VALIDATION...DISTRIBUTION UNLIMITED. AFIT/GIR/ENV/06M-05 CORPORATE ENTREPRENEURSHIP ASSESSMENT INSTRUMENT (CEAI): SYSTEMATIC VALIDATION OF A MEASURE
Measuring quality of life in opioid-dependent people: a systematic review of assessment instruments.
Strada, Lisa; Vanderplasschen, Wouter; Buchholz, Angela; Schulte, Bernd; Muller, Ashley E; Verthein, Uwe; Reimer, Jens
2017-12-01
Opioid dependence is a chronic relapsing disorder. Despite increasing research on quality of life (QOL) in people with opioid dependence, little attention has been paid to the instruments used. This systematic review examines the suitability of QOL instruments for use in opioid-dependent populations and the instruments' quality. A systematic search was performed in the databases Medline, PsycInfo, The Cochrane Library, and CINAHL. Articles were eligible if they assessed QOL of opioid-dependent populations using a validated QOL instrument. Item content relevance to opioid-dependent people was evaluated by means of content analysis, and instrument properties were assessed using minimum standards for patient-reported outcome measures. Eighty-nine articles were retrieved, yielding sixteen QOL instruments, of which ten were assessed in this review. Of the ten instruments, six were disease specific, but none for opioid dependence. Two instruments had good item content relevance. The conceptual and measurement model were described in seven instruments. Four instruments were developed with input from the respective target population. Eight instruments had low respondent and administrator burden. Psychometric properties were either not assessed in opioid-dependent populations or were inconclusive or moderate. No instrument scored perfectly on both the content and properties. The limited suitability of instruments for opioid-dependent people hinders accurate and sensitive measurement of QOL in this population. Future research is in need of an opioid dependence-specific QOL instrument to measure the true impact of the disease on people's lives and to evaluate treatment-related services.
The quality of instruments to assess the process of shared decision making: A systematic review.
Gärtner, Fania R; Bomhof-Roordink, Hanna; Smith, Ian P; Scholl, Isabelle; Stiggelbout, Anne M; Pieterse, Arwen H
2018-01-01
To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument's content and characteristics such as the perspective that they assess. We recommend refinement and validation of existing instruments, and the use of COSMIN-guidelines to help guarantee high-quality evaluations.
Joseph‐Williams, Natalie; Edwards, Adrian; Elwyn, Glyn
2011-01-01
Abstract Background or context Regret is a common consequence of decisions, including those decisions related to individuals’ health. Several assessment instruments have been developed that attempt to measure decision regret. However, recent research has highlighted the complexity of regret. Given its relevance to shared decision making, it is important to understand its conceptualization and the instruments used to measure it. Objectives To review current conceptions of regret. To systematically identify instruments used to measure decision regret and assess whether they capture recent conceptualizations of regret. Search strategy Five electronic databases were searched in 2008. Search strategies used a combination of MeSH terms (or database equivalent) and free text searching under the following key headings: ‘Decision’ and ‘regret’ and ‘measurement’. Follow‐up manual searches were also performed. Inclusion criteria Articles were included if they reported the development and psychometric testing of an instrument designed to measure decision regret, or the use of a previously developed and tested instrument. Main results Thirty‐two articles were included: 10 report the development and validation of an instrument that measures decision regret and 22 report the use of a previously developed and tested instrument. Content analysis found that existing instruments for the measurement of regret do not capture current conceptualizations of regret and they do not enable the construct of regret to be measured comprehensively. Conclusions Existing instrumentation requires further development. There is also a need to clarify the purpose for using regret assessment instruments as this will, and should, focus their future application. PMID:20860776
Heinl, D; Prinsen, C A C; Deckert, S; Chalmers, J R; Drucker, A M; Ofenloch, R; Humphreys, R; Sach, T; Chamlin, S L; Schmitt, J; Apfelbacher, C
2016-03-01
The Harmonising Outcome Measures for Eczema (HOME) initiative has identified quality of life (QoL) as a core outcome domain to be evaluated in every eczema trial. It is unclear which of the existing QoL instruments is most appropriate for this domain. Thus, the aim of this review was to systematically assess the measurement properties of existing measurement instruments developed and/or validated for the measurement of QoL in adult eczema. We conducted a systematic literature search in PubMed and Embase identifying studies on measurement properties of adult eczema QoL instruments. For all eligible studies, we assessed the adequacy of the measurement properties and the methodological quality with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis summarizing findings from different studies was the basis to assign four degrees of recommendation (A-D). A total of 15 articles reporting on 17 instruments were included. No instrument fulfilled the criteria for category A. Six instruments were placed in category B, meaning that they have the potential to be recommended depending on the results of further validation studies. Three instruments had poor adequacy in at least one required adequacy criterion and were therefore put in category C. The remaining eight instruments were minimally validated and were thus placed in category D. Currently, no QoL instrument can be recommended for use in adult eczema. The Quality of Life Index for Atopic Dermatitis (QoLIAD) and the Dermatology Life Quality Index (DLQI) are recommended for further validation research. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chen, Xin-Lin; Zhong, Liang-Huan; Wen, Yi; Liu, Tian-Wen; Li, Xiao-Ying; Hou, Zheng-Kun; Hu, Yue; Mo, Chuan-Wei; Liu, Feng-Bin
2017-09-15
This review aims to critically appraise and compare the measurement properties of inflammatory bowel disease (IBD)-specific health-related quality of life instruments. Medline, EMBASE and ISI Web of Knowledge were searched from their inception to May 2016. IBD-specific instruments for patients with Crohn's disease, ulcerative colitis or IBD were enrolled. The basic characteristics and domains of the instruments were collected. The methodological quality of measurement properties and measurement properties of the instruments were assessed. Fifteen IBD-specific instruments were included, which included twelve instruments for adult IBD patients and three for paediatric IBD patients. All of the instruments were developed in North American and European countries. The following common domains were identified: IBD-related symptoms, physical, emotional and social domain. The methodological quality was satisfactory for content validity; fair in internal consistency, reliability, structural validity, hypotheses testing and criterion validity; and poor in measurement error, cross-cultural validity and responsiveness. For adult IBD patients, the IBDQ-32 and its short version (SIBDQ) had good measurement properties and were the most widely used worldwide. For paediatric IBD patients, the IMPACT-III had good measurement properties and had more translated versions. Most methodological quality should be promoted, especially measurement error, cross-cultural validity and responsiveness. The IBDQ-32 was the most widely used instrument with good reliability and validity, followed by the SIBDQ and IMPACT-III. Further validation studies are necessary to support the use of other instruments.
Diabetes-related emotional distress instruments: a systematic review of measurement properties.
Lee, Jiyeon; Lee, Eun-Hyun; Kim, Chun-Ja; Moon, Seung Hei
2015-12-01
The objectives of this study were to identify all available diabetes-related emotional distress instruments and evaluate the evidence regarding their measurement properties to help in the selection of the most appropriate instrument for use in practice and research. A systematic literature search was performed. PubMed, Embase, CINAHL, and PsycINFO were searched systematically for articles on diabetes-related emotional distress instruments. The Consensus-based Standards for the Selection of Health Measurement Instruments checklist was used to evaluate the methodological quality of the identified studies. The quality of results with respect to the measurement properties of each study was evaluated using Terwee's quality criteria. An ancillary meta-analysis was performed. Of the 2345 articles yielded by the search, 19 full-text articles evaluating 6 diabetes-related emotional distress instruments were included in this study. No instrument demonstrated evidence for all measurement properties. The Problem Areas in Diabetes scale (PAID) was the most frequently studied and the best validated of the instruments. Pooled summary estimates of the correlation coefficient between the PAID and serum glycated hemoglobin revealed a positive but weak correlation. No diabetes-related emotional distress instrument demonstrated evidence for all measurement properties. No instrument was better than another, although the PAID was the best validated and is thus recommended for use. Further psychometric studies of the diabetes-related emotional distress instruments with rigorous methodologies are required. Copyright © 2015 Elsevier Ltd. All rights reserved.
The PEACE project review of clinical instruments for hospice and palliative care.
Hanson, Laura C; Scheunemann, Leslie P; Zimmerman, Sheryl; Rokoske, Franziska S; Schenck, Anna P
2010-10-01
Hospice and palliative care organizations are expanding their use of standardized instruments and other approaches to measure quality. We undertook a systematic review and evaluation of published patient-level instruments for potential application in hospice and palliative care clinical quality measurement. We searched prior reviews and computerized reference databases from 1990 through February 2007 for studies of instruments relevant to physical, psychological, social, cultural, spiritual, or ethical aspects of palliative care, or measuring prognosis, function or continuity of care. Publications were selected for full review if they provided evidence of psychometric properties or practical application of an instrument tested in or appropriate for a hospice or palliative care population. Selected instruments were evaluated and scored for scientific soundness and potential application in clinical quality measurement. The search found 1427 publications, with 229 selected for full manuscript review. Manuscripts provided information on 129 instruments which were evaluated using a structured scoring guide for psychometric properties. Thirty-nine instruments scoring near or above the 75th percentile were recommended. Most instruments covered multiple domains or focused on care for physical symptoms, psychological or social aspects of care. Few instruments were available to measure cultural aspects of care, structure and process of care, and continuity of care. Numerous patient-level instruments are available to measure physical, psychological and social aspects of palliative care with adequate evidence for scientific soundness and practical clinical use for quality improvement and research. Other aspects of palliative care may benefit from further instrument development research.
Okan, Orkan; Lopes, Ester; Bollweg, Torsten Michael; Bröder, Janine; Messer, Melanie; Bruland, Dirk; Bond, Emma; Carvalho, Graça S; Sørensen, Kristine; Saboga-Nunes, Luis; Levin-Zamir, Diane; Sahrai, Diana; Bittlingmayer, Uwe H; Pelikan, Jürgen M; Thomas, Malcolm; Bauer, Ullrich; Pinheiro, Paulo
2018-01-22
Health literacy is an important health promotion concern and recently children and adolescents have been the focus of increased academic attention. To assess the health literacy of this population, researchers have been focussing on developing instruments to measure their health literacy. Compared to the wider availability of instruments for adults, only a few tools are known for younger age groups. The objective of this study is to systematically review the field of generic child and adolescent health literacy measurement instruments that are currently available. A systematic literature search was undertaken in five databases (PubMed, CINAHL, PsycNET, ERIC, and FIS) on articles published between January 1990 and July 2015, addressing children and adolescents ≤18 years old. Eligible articles were analysed, data was extracted, and synthesised according to review objectives. Fifteen generic health literacy measurement instruments for children and adolescents were identified. All, except two, are self-administered instruments. Seven are objective measures (performance-based tests), seven are subjective measures (self-reporting), and one uses a mixed-method measurement. Most instruments applied a broad and multidimensional understanding of health literacy. The instruments were developed in eight different countries, with most tools originating in the United States (n = 6). Among the instruments, 31 different components related to health literacy were identified. Accordingly, the studies exhibit a variety of implicit or explicit conceptual and operational definitions, and most instruments have been used in schools and other educational contexts. While the youngest age group studied was 7-year-old children within a parent-child study, there is only one instrument specifically designed for primary school children and none for early years. Despite the reported paucity of health literacy research involving children and adolescents, an unexpected number of health literacy measurement studies in children's populations was found. Most instruments tend to measure their own specific understanding of health literacy and not all provide sufficient conceptual information. To advance health literacy instruments, a much more standardised approach is necessary including improved reporting on the development and validation processes. Further research is required to improve health literacy instruments for children and adolescents and to provide knowledge to inform effective interventions.
Calibration of solar radiation measuring instruments. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bahm, R J; Nakos, J C
A review of solar radiation measurement of instruments and some types of errors is given; and procedures for calibrating solar radiation measuring instruments are detailed. An appendix contains a description of various agencies who perform calibration of solar instruments and a description of the methods they used at the time this report was prepared. (WHK)
NASA Technical Reports Server (NTRS)
Roder, H. M.
1974-01-01
Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.
Lee, Eun-Hyun; Kim, Chun-Ja; Lee, Jiyeon; Moon, Seung Hei
2017-09-01
The aims of this study were to identify all available self-administered instruments measuring health literacy in people with diabetes and to determine the current instrument that is the most appropriate for applying to this population in both practice and research. A systematic review of measurement properties. MEDLINE, EMBASE and CINAHL electronic databases from their inception up to 28 March 2016. The methodological quality of each included study was assessed using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. The reported results for measurement properties in the studies were assessed according to Terwee's quality criteria. Thirteen self-administered instruments measuring health literacy in people with diabetes were identified, of which six (44%) were diabetes-specific instruments. The instruments that covered the broadest contents of health literacy were the Health Literacy Scale and Health Literacy Questionnaire. The (test-retest) reliability, measurement error and responsiveness were not evaluated for any instrument, while internal consistency and hypothesis testing validity were the most frequently assessed measurement properties. With the current evidence, the Health Literacy Scale may be the most appropriate instrument for patients with diabetes in practice and research. However, the structural validity of this scale needs to be further established, particularly in other language versions. It is also recommended to use the Diabetes Numeracy Test-15 along with the Health Literacy Scale to complement the lack of numeracy measures in the Health Literacy Scale. © 2017 John Wiley & Sons Ltd.
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Measurement instrumentation. 201.22 Section 201.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Measurement instrumentation. 201.22 Section 201.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...
40 CFR 201.22 - Measurement instrumentation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Measurement instrumentation. 201.22 Section 201.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT... Criteria § 201.22 Measurement instrumentation. (a) A sound level meter or alternate sound level measurement...
Cavity-Enhanced Quantum-Cascade Laser-Based Instrument for Trace gas Measurements
NASA Astrophysics Data System (ADS)
Provencal, R.; Gupta, M.; Owano, T.; Baer, D.; Ricci, K.; O'Keefe, A.
2005-12-01
An autonomous instrument based on Off-Axis Integrated Cavity Output Spectroscopy has been successfully deployed for measurements of CO in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument consists of a measurement cell comprised of two high reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data acquisition electronics, and data analysis software. The instrument reports CO mixing ratio at a 1-Hz rate based on measured absorption, gas temperature and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41000 ft, the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights. We will also present recent development efforts to extend the instrument's capabilities for the measurements of CH4, N2O and CO in real time.
[An instrument for estimating human body composition using impedance measurement].
Yin, J; Peng, C
1997-03-01
According to the impedance feature of biological tissue, the instrument was designed at 1, 5, 10, 50, 100kHz to measure human impedance, and then to calculate human FAT, FFM, FAT%, TBW, ECW, ICW and so on. A 8031 singlechip microprocessor contacuting used as a control center in the instrument. The part of electric circuit contacuting human body in the instrument was unreally earthing. The instrument was safty, effective, repeatable, and easily manpulative. Prelimintary clinical experiment showed the results measured with the instrument could effectively reflect practical, status of human composition.
Instrumentation of sampling aircraft for measurement of launch vehicle effluents
NASA Technical Reports Server (NTRS)
Wornom, D. E.; Woods, D. C.; Thomas, M. E.; Tyson, R. W.
1977-01-01
An aircraft was selected and instrumented to measure effluents emitted from large solid propellant rockets during launch activities. The considerations involved in aircraft selection, sampling probes, and instrumentation are discussed with respect to obtaining valid airborne measurements. Discussions of the data acquisition system used, the instrument power system, and operational sampling procedures are included. Representative measurements obtained from an actual rocket launch monitoring activity are also presented.
Gerbens, L A A; Prinsen, C A C; Chalmers, J R; Drucker, A M; von Kobyletzki, L B; Limpens, J; Nankervis, H; Svensson, Å; Terwee, C B; Zhang, J; Apfelbacher, C J; Spuls, P I
2017-01-01
Symptoms have been identified as a core outcome domain for atopic eczema (AE) trials. Various instruments exist to measure symptoms in AE, but they vary in quality and there is a lack of standardization between clinical trials. Our objective was to systematically evaluate the quality of the evidence on the measurement properties of AE symptom instruments, thereby informing consensus discussions within the Harmonising Outcome Measures for Eczema (HOME) initiative regarding the most appropriate instruments for the core outcome domain symptoms. Using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist and predefined criteria for good measurement properties on identified development and validation studies of AE symptom instruments, a best evidence synthesis was performed to draw an overall conclusion on quality of the instruments and to provide recommendations. Eighteen instruments were identified and evaluated. When the quality and results of the studies were considered, only five of these instruments had sufficient validation data to consider them for the core outcome set for the core outcome domain symptoms. These were the paediatric Itch Severity Scale (ISS), Patient-Oriented Eczema Measure (POEM), Patient-Oriented SCOring Atopic Dermatitis (PO-SCORAD), Self-Administered Eczema Area and Severity Index (SA-EASI) and adapted SA-EASI. ISS (paediatric version), POEM, PO-SCORAD, SA-EASI and adapted SA-EASI are currently the most appropriate instruments and therefore have the potential to be recommended as core symptom instrument in future clinical trials. These findings will be utilized for the development of a core outcome set for AE. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Instruments to measure behavioural and psychological symptoms of dementia.
van der Linde, Rianne M; Stephan, Blossom C M; Dening, Tom; Brayne, Carol
2014-03-01
Reliable and valid measurement of behavioural and psychological symptoms of dementia (BPSD) is important for research and clinical practice. Here we provide an overview of the different instruments and discuss issues involved in the choice of the most appropriate instrument to measure BPSD in research. A list of BPSD instruments was generated. For each instrument Pubmed and SCOPUS were searched for articles that reported on their use or quality. Eighty-three instruments that are used to measure BPSD were identified. Instruments differ in length and detail, whether the interview is with participants, informants or by observation, the target sample and the time frames for use. Reliability and validity is generally good, but reported in few independent samples. When choosing a BPSD instrument for research the research question should be carefully scrutinised and the symptoms of interest, population, quality, detail, time frame and practical issues should be considered. Copyright © 2014 John Wiley & Sons, Ltd.
Five instruments for measuring tree height: an evaluation
Michael S. Williams; William A. Bechtold; V.J. LaBau
1994-01-01
Five instruments were tested for reliability in measuring tree heights under realistic conditions. Four linear models were used to determine if tree height can be measured unbiasedly over all tree sizes and if any of the instruments were more efficient in estimating tree height. The laser height finder was the only instrument to produce unbiased estimates of the true...
Measurement Properties of Questionnaires Measuring Continuity of Care: A Systematic Review
Uijen, Annemarie A.; Heinst, Claire W.; Schellevis, Francois G.; van den Bosch, Wil J.H.M.; van de Laar, Floris A.; Terwee, Caroline B.; Schers, Henk J.
2012-01-01
Background Continuity of care is widely acknowledged as a core value in family medicine. In this systematic review, we aimed to identify the instruments measuring continuity of care and to assess the quality of their measurement properties. Methods We did a systematic review using the PubMed, Embase and PsycINFO databases, with an extensive search strategy including ‘continuity of care’, ‘coordination of care’, ‘integration of care’, ‘patient centered care’, ‘case management’ and its linguistic variations. We searched from 1995 to October 2011 and included articles describing the development and/or evaluation of the measurement properties of instruments measuring one or more dimensions of continuity of care (1) care from the same provider who knows and follows the patient (personal continuity), (2) communication and cooperation between care providers in one care setting (team continuity), and (3) communication and cooperation between care providers in different care settings (cross-boundary continuity). We assessed the methodological quality of the measurement properties of each instrument using the COSMIN checklist. Results We included 24 articles describing the development and/or evaluation of 21 instruments. Ten instruments measured all three dimensions of continuity of care. Instruments were developed for different groups of patients or providers. For most instruments, three or four of the six measurement properties were assessed (mostly internal consistency, content validity, structural validity and construct validity). Six instruments scored positive on the quality of at least three of six measurement properties. Conclusions Most included instruments have problems with either the number or quality of its assessed measurement properties or the ability to measure all three dimensions of continuity of care. Based on the results of this review, we recommend the use of one of the four most promising instruments, depending on the target population Diabetes Continuity of Care Questionnaire, Alberta Continuity of Services Scale-Mental Health, Heart Continuity of Care Questionnaire, and Nijmegen Continuity Questionnaire. PMID:22860100
Engel, Lisa; Chui, Adora; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R
2018-03-07
To critically appraise the measurement property evidence (ie, psychometric) for 8 observation-based financial management assessment instruments. Seven databases were searched in May 2015. Two reviewers used an independent decision-agreement process to select studies of measurement property evidence relevant to populations with adulthood acquired cognitive impairment, appraise the quality of the evidence, and extract data. Twenty-one articles were selected. This review used the COnsensus-based Standards for the selection of health Measurement Instruments review guidelines and 4-point tool to appraise evidence. After appraising the methodologic quality, the adequacy of results and volume of evidence per instrument were synthesized. Measurement property evidence with high risk of bias was excluded from the synthesis. The volume of measurement property evidence per instrument is low; most instruments had 1 to 3 included studies. Many included studies had poor methodologic quality per measurement property evidence area examined. Six of the 8 instruments reviewed had supporting construct validity/hypothesis-testing evidence of fair methodologic quality. There is a dearth of acceptable quality content validity, reliability, and responsiveness evidence for all 8 instruments. Rehabilitation practitioners assess financial management functions in adults with acquired cognitive impairments. However, there is limited published evidence to support using any of the reviewed instruments. Practitioners should exercise caution when interpreting the results of these instruments. This review highlights the importance of appraising the quality of measurement property evidence before examining the adequacy of the results and synthesizing the evidence. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Urpí-Fernández, Ana-María; Zabaleta-Del-Olmo, Edurne; Montes-Hidalgo, Javier; Tomás-Sábado, Joaquín; Roldán-Merino, Juan-Francisco; Lluch-Canut, María-Teresa
2017-12-01
To identify, critically appraise and summarize the measurement properties of instruments to assess self-care in healthy children. Assessing self-care is a proper consideration for nursing practice and nursing research. No systematic review summarizes instruments of measurement validated in healthy children. Psychometric review in accordance with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. MEDLINE, CINAHL, PsycINFO, Web of Science and Open Grey were searched from their inception to December 2016. Validation studies with a healthy child population were included. Search was not restricted by language. Two reviewers independently assessed the methodological quality of included studies using the COSMIN checklist. Eleven studies were included in the review assessing the measurement properties of ten instruments. There was a maximum of two studies per instrument. None of the studies evaluated the properties of test-retest reliability, measurement error, criterion validity and responsiveness. Internal consistency and structural validity were rated as "excellent" or "good" in four studies. Four studies were rated as "excellent" in content validity. Cross-cultural validity was rated as "poor" in the two studies (three instruments) which cultural adaptation was carried out. The evidence available does not allow firm conclusions about the instruments identified in terms of reliability and validity. Future research should focus on generate evidence about a wider range of measurement properties of these instruments using a rigorous methodology, as well as instrument testing on different countries and child population. © 2017 John Wiley & Sons Ltd.
de Vries, C E E; Kalff, M C; Prinsen, C A C; Coulman, K D; den Haan, C; Welbourn, R; Blazeby, J M; Morton, J M; van Wagensveld, B A
2018-06-08
The objective of this study is to systematically assess the quality of existing patient-reported outcome measures developed and/or validated for Quality of Life measurement in bariatric surgery (BS) and body contouring surgery (BCS). We conducted a systematic literature search in PubMed, EMBASE, PsycINFO, CINAHL, Cochrane Database Systematic Reviews and CENTRAL identifying studies on measurement properties of BS and BCS Quality of Life instruments. For all eligible studies, we evaluated the methodological quality of the studies by using the COnsensus-based Standards for the selection of health Measurement INstruments checklist and the quality of the measurement instruments by applying quality criteria. Four degrees of recommendation were assigned to validated instruments (A-D). Out of 4,354 articles, a total of 26 articles describing 24 instruments were included. No instrument met all requirements (category A). Seven instruments have the potential to be recommended depending on further validation studies (category B). Of these seven, the BODY-Q has the strongest evidence for content validity in BS and BCS. Two instruments had poor quality in at least one required quality criterion (category C). Fifteen instruments were minimally validated (category D). The BODY-Q, developed for BS and BCS, possessed the strongest evidence for quality of measurement properties and has the potential to be recommended in future clinical trials. © 2018 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of World Obesity Federation.
2013-01-01
During the last decade, there has been a rapid increase in development of instruments to measure parent food practices. Because these instruments often measure different constructs, or define common constructs differently, an evaluation of these instruments is needed. A systematic review of the literature was conducted to identify existing measures of parent food practices and to assess the quality of their development. The initial search used terms capturing home environment, parenting behaviors, feeding practices and eating behaviors, and was performed in October of 2009 using PubMed/Medline, PsychInfo, Web of knowledge (ISI), and ERIC, and updated in July of 2012. A review of titles and abstracts was used to narrow results, after which full articles were retrieved and reviewed. Only articles describing development of measures of parenting food practices designed for families with children 2-12 years old were retained for the current review. For each article, two reviewers extracted data and appraised the quality of processes used for instrument development and evaluation. The initial search yielded 28,378 unique titles; review of titles and abstracts narrowed the pool to 1,352 articles; from which 57 unique instruments were identified. The review update yielded 1,772 new titles from which14 additional instruments were identified. The extraction and appraisal process found that 49% of instruments clearly identified and defined concepts to be measured, and 46% used theory to guide instrument development. Most instruments (80%) had some reliability testing, with internal consistency being the most common (79%). Test-retest or inter-rater reliability was reported for less than half the instruments. Some form of validity evidence was reported for 84% of instruments. Construct validity was most commonly presented (86%), usually with analysis of associations with child diet or weight/BMI. While many measures of food parenting practices have emerged, particularly in recent years, few have demonstrated solid development methods. Substantial variation in items across different scales/constructs makes comparison between instruments extremely difficult. Future efforts should be directed toward consensus development of food parenting practices constructs and measures. PMID:23688157
Che, Chong Chin; Hairi, Noran Naqiah; Chong, Mei Chan
2017-09-01
To review systematically the psychometric properties of instruments used to measure intention to work with older people. Nursing students are part of the future healthcare workforce; thus, being aware of their intention to work with older people would give valuable insights to nursing education and practice. Despite a plethora of research on measuring intention to work with older people, a valid and reliable instrument has not been identified. A systematic literature review of evidence and psychometric properties. Eight database searches were conducted between 2006 - 2016. English articles were selected based on inclusion and exclusion criteria. The COSMIN checklist was used to assess instruments reporting a psychometric evaluation of validity and reliability. Of 41 studies identified for full text review, 36 met the inclusion criteria. Seven different types of instruments were identified for psychometric evaluation. Measures of reliability were reported in eight papers and validity in five papers. Evidence for each measurement property was limited, with each instrument demonstrating a lack of information on measurement properties. Based on the COSMIN checklist, the overall quality of the psychometric properties was rated as poor to good. No single instrument was found to be optimal for use. Studies of high methodological quality are needed to properly assess the measurement properties of the instruments that are currently available. Until such studies are available, we recommend using existing instruments with caution. © 2017 John Wiley & Sons Ltd.
A review of instruments to measure interprofessional team-based primary care.
Shoemaker, Sarah J; Parchman, Michael L; Fuda, Kathleen Kerwin; Schaefer, Judith; Levin, Jessica; Hunt, Meaghan; Ricciardi, Richard
2016-07-01
Interprofessional team-based care is increasingly regarded as an important feature of delivery systems redesigned to provide more efficient and higher quality care, including primary care. Measurement of the functioning of such teams might enable improvement of team effectiveness and could facilitate research on team-based primary care. Our aims were to develop a conceptual framework of high-functioning primary care teams to identify and review instruments that measure the constructs identified in the framework, and to create a searchable, web-based atlas of such instruments (available at: http://primarycaremeasures.ahrq.gov/team-based-care/ ). Our conceptual framework was developed from existing frameworks, the teamwork literature, and expert input. The framework is based on an Input-Mediator-Output model and includes 12 constructs to which we mapped both instruments as a whole, and individual instrument items. Instruments were also reviewed for relevance to measuring team-based care, and characterized. Instruments were identified from peer-reviewed and grey literature, measure databases, and expert input. From nearly 200 instruments initially identified, we found 48 to be relevant to measuring team-based primary care. The majority of instruments were surveys (n = 44), and the remainder (n = 4) were observational checklists. Most instruments had been developed/tested in healthcare settings (n = 30) and addressed multiple constructs, most commonly communication (n = 42), heedful interrelating (n = 42), respectful interactions (n = 40), and shared explicit goals (n = 37). The majority of instruments had some reliability testing (n = 39) and over half included validity testing (n = 29). Currently available instruments offer promise to researchers and practitioners to assess teams' performance, but additional work is needed to adapt these instruments for primary care settings.
Research instrumentation for hot section components of turbine engines
NASA Technical Reports Server (NTRS)
Englund, D. R.
1986-01-01
Programs to develop research instrumentation for use on hot section components of turbine engines are discussed. These programs can be separated into two categories: one category includes instruments which can measure the environment within the combustor and turbine components, the other includes instruments which measure the response of engine components to the imposed environment. Included in the first category are instruments to measure total heat flux and fluctuating gas temperature. High temperature strain measuring systems, thin film sensors (e.g., turbine blade thermocouples) and a system to view the interior of a combustor during engine operation are programs which comprise the second category. The paper will describe the state of development of these sensors and measuring systems and, in some cases, show examples of measurements made with this instrumentation. The discussion will cover work done at NASA Lewis and at various contractor facilities.
Comparison of non-invasive tear film stability measurement techniques.
Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P
2018-01-01
Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p < 0.001) but not between the hand-held device and the instrument-mounted techniques (all p > 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p < 0.05), while no significant differences were observed between the two instrument-mounted devices (all p > 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.
Comparing measurement response and inverted results of electrical resistivity tomography instruments
Parsekian, Andrew D.; Claes, Niels; Singha, Kamini; Minsley, Burke J.; Carr, Bradley; Voytek, Emily; Harmon, Ryan; Kass, Andy; Carey, Austin; Thayer, Drew; Flinchum, Brady
2017-01-01
In this investigation, we compare the results of electrical resistivity measurements made by six commercially available instruments on the same line of electrodes to determine if there are differences in the measured data or inverted results. These comparisons are important to determine whether measurements made between different instruments are consistent. We also degraded contact resistance on one quarter of the electrodes to study how each instrument responds to different electrical connection with the ground. We find that each instrument produced statistically similar apparent resistivity results, and that any conservative assessment of the final inverted resistivity models would result in a similar interpretation for each. We also note that inversions, as expected, are affected by measurement error weights. Increased measurement errors were most closely associated with degraded contact resistance in this set of experiments. In a separate test we recorded the full measured waveform for a single four-electrode array to show how poor electrode contact and instrument-specific recording settings can lead to systematic measurement errors. We find that it would be acceptable to use more than one instrument during an investigation with the expectation that the results would be comparable assuming contact resistance remained consistent.
Clinical utility of measures of breathlessness.
Cullen, Deborah L; Rodak, Bernadette
2002-09-01
The clinical utility of measures of dyspnea has been debated in the health care community. Although breathlessness can be evaluated with various instruments, the most effective dyspnea measurement tool for patients with chronic lung disease or for measuring treatment effectiveness remains uncertain. Understanding the evidence for the validity and reliability of these instruments may provide a basis for appropriate clinical application. Evaluate instruments designed to measure breathlessness, either as single-symptom or multidimensional instruments, based on psychometrics foundations such as validity, reliability, and discriminative and evaluative properties. Classification of each dyspnea measurement instrument will recommend clinical application in terms of exercise, benchmarking patients, activities of daily living, patient outcomes, clinical trials, and responsiveness to treatment. Eleven dyspnea measurement instruments were selected. Each instrument was assessed as discriminative or evaluative and then analyzed as to its psychometric properties and purpose of design. Descriptive data from all studies were described according to their primary patient application (ie, chronic obstructive pulmonary disease, asthma, or other patient populations). The Borg Scale and the Visual Analogue Scale are applicable to exertion and thus can be applied to any cardiopulmonary patient to determine dyspnea. All other measures were determined appropriate for chronic obstructive pulmonary disease, whereas the Shortness of Breath Questionnaire can be applied to cystic fibrosis and lung transplant patients. The most appropriate utility for all instruments was measuring the effects on activities of daily living and for benchmarking patient progress. Instruments that quantify function and health-related quality of life have great utility for documenting outcomes but may be limited as to documenting treatment responsiveness in terms of clinically important changes. The dyspnea measurement instruments we studied meet important standards of validity and reliability. Discriminative measures have limited clinical utility and, when used for populations or conditions for which they are not designed or validated, the data collected may not be clinically relevant. Evaluative measures have greater clinical utility and can be applied for outcome purposes. Measures should be applied to the populations and conditions for which they were designed. The relationship between clinical therapies and the measurement of dyspnea as an outcome can develop as respiratory therapists become more comfortable with implementing dyspnea measurement instruments and use the data to improve patient treatment. Dyspnea evaluation should be considered for all clinical practice guidelines and care pathways.
NASA Technical Reports Server (NTRS)
McPeters, Richard; Bhartia, P. K. (Technical Monitor)
2002-01-01
The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical distribution, the SBUV and SAGE (Stratospheric Aerosol and Gas Experiment) instruments for example, show that the largest changes are occurring in the lower stratosphere and upper troposphere. The goal of ozone measurement in the next decades will be to document the predicted recovery of the ozone layer as CFC (chlorofluorocarbon) levels decline. This will require a continuation of global measurements of total column ozone on a global basis, but using data from successor instruments to TOMS. Hyperspectral instruments capable of measuring in the UV will be needed for this purpose. Establishing the relative roles of chemistry and dynamics will require instruments to measure ozone in the troposphere and in the stratosphere with good vertical resolution. Instruments that can measure other chemicals important to ozone formation and destruction will also be needed.
Integrating Validity Theory with Use of Measurement Instruments in Clinical Settings
Kelly, P Adam; O'Malley, Kimberly J; Kallen, Michael A; Ford, Marvella E
2005-01-01
Objective To present validity concepts in a conceptual framework useful for research in clinical settings. Principal Findings We present a three-level decision rubric for validating measurement instruments, to guide health services researchers step-by-step in gathering and evaluating validity evidence within their specific situation. We address construct precision, the capacity of an instrument to measure constructs it purports to measure and differentiate from other, unrelated constructs; quantification precision, the reliability of the instrument; and translation precision, the ability to generalize scores from an instrument across subjects from the same or similar populations. We illustrate with specific examples, such as an approach to validating a measurement instrument for veterans when prior evidence of instrument validity for this population does not exist. Conclusions Validity should be viewed as a property of the interpretations and uses of scores from an instrument, not of the instrument itself: how scores are used and the consequences of this use are integral to validity. Our advice is to liken validation to building a court case, including discovering evidence, weighing the evidence, and recognizing when the evidence is weak and more evidence is needed. PMID:16178998
Phonation Quotient in Women: A Measure of Vocal Efficiency Using Three Aerodynamic Instruments.
Joshi, Ashwini; Watts, Christopher R
2017-03-01
The purpose of this study was to examine measures of vital capacity and phonation quotient across three age groups in women using three different aerodynamic instruments representing low-tech and high-tech options. This study has a prospective, repeated measures design. Fifteen women in each age group of 25-39 years, 40-59 years, and 60-79 years were assessed using maximum phonation time and vital capacity obtained from three aerodynamic instruments: a handheld analog windmill type spirometer, a handheld digital spirometer, and the Phonatory Aerodynamic System (PAS), Model 6600. Phonation quotient was calculated using vital capacity from each instrument. Analyses of variance were performed to test for main effects of the instruments and age on vital capacity and derived phonation quotient. Pearson product moment correlation was performed to assess measurement reliability (parallel forms) between the instruments. Regression equations, scatterplots, and coefficients of determination were also calculated. Statistically significant differences were found in vital capacity measures for the digital spirometer compared with the windmill-type spirometer and PAS across age groups. Strong positive correlations were present between all three instruments for both vital capacity and derived phonation quotient measurements. Measurement precision for the digital spirometer was lower than the windmill spirometer compared with the PAS. However, all three instruments had strong measurement reliability. Additionally, age did not have an effect on the measurement across instruments. These results are consistent with previous literature reporting data from male speakers and support the use of low-tech options for measurement of basic aerodynamic variables associated with voice production. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Measurement theory in local quantum physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okamura, Kazuya, E-mail: okamura@math.cm.is.nagoya-u.ac.jp; Ozawa, Masanao, E-mail: ozawa@is.nagoya-u.ac.jp
In this paper, we aim to establish foundations of measurement theory in local quantum physics. For this purpose, we discuss a representation theory of completely positive (CP) instruments on arbitrary von Neumann algebras. We introduce a condition called the normal extension property (NEP) and establish a one-to-one correspondence between CP instruments with the NEP and statistical equivalence classes of measuring processes. We show that every CP instrument on an atomic von Neumann algebra has the NEP, extending the well-known result for type I factors. Moreover, we show that every CP instrument on an injective von Neumann algebra is approximated bymore » CP instruments with the NEP. The concept of posterior states is also discussed to show that the NEP is equivalent to the existence of a strongly measurable family of posterior states for every normal state. Two examples of CP instruments without the NEP are obtained from this result. It is thus concluded that in local quantum physics not every CP instrument represents a measuring process, but in most of physically relevant cases every CP instrument can be realized by a measuring process within arbitrary error limits, as every approximately finite dimensional von Neumann algebra on a separable Hilbert space is injective. To conclude the paper, the concept of local measurement in algebraic quantum field theory is examined in our framework. In the setting of the Doplicher-Haag-Roberts and Doplicher-Roberts theory describing local excitations, we show that an instrument on a local algebra can be extended to a local instrument on the global algebra if and only if it is a CP instrument with the NEP, provided that the split property holds for the net of local algebras.« less
The Future of Carbon Monoxide Measurements from Space
NASA Astrophysics Data System (ADS)
Drummond, J.
It is now over 20 years since the Measurements of Air Pollution from Space MAPS instrument made the first measurements of tropospheric carbon monoxide from the shuttle Since that time a number of instruments have flown including the Measurements Of Pollution In The Troposphere MOPITT Tropospheric Emission Spectrometer TES and SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY SCIAMCHY to name only three of many Each of these instruments has a unique observing method and unique mission characteristics It is accepted that measurements of carbon monoxide provide a useful proxy of the pollution of the troposphere and contribute significantly to studies of various phenomena in the atmosphere and atmosphere-surface interactions These measurements should therefore be continued -- but in what form Technology has progresses significantly since the current generation of instruments was designed and our ability to interpret the data from such instrumentation has likewise expanded It is therefore fruitful to consider what is the best set of measurements that can be made which parameters should be emphasized and which compromised on the way to the next generation of sensors The Measurements of Air Pollution Levels in the Environment MAPLE instrument is a study financed by the Canadian Space Agency to design a next-generation instrument and since instrument spacecraft and mission are now intimately linked a consideration of the whole mission is appropriate This talk will outline some potential developments in the hardware
Results from the 1995 Stratospheric Ozone Profile Intercomparison at Mauna Loa (MLO3)
NASA Technical Reports Server (NTRS)
McPeters, R. D.; Hofmann, D. J.; Clark, M.; Flynn, L.; Froidevaux, L.; Gross, M.; Johnson, B.; Koenig, G.; Liu, X.; McDermid, S.;
1998-01-01
In August 1995 multiple instruments that measure the stratospheric ozone vertical distribution were intercompared at the Mauna Loa Observatory, Hawaii, under the auspices of the Network for the Detection of Stratospheric Change. The instruments included two UV lidar systems, one from JPL and the other from Goddard Space Flight Center, ECC balloon-sondes, a ground-based microwave instrument, Umkehr measurements, and a new ground-based FTIR instrument. The MLS instrument on the UARS satellite provided correlative profiles of ozone, and there was one close overpass of the SAGE II instrument. The results show that much better consistency among instruments is being achieved than even a few years ago, usually to within the instrument uncertainties. The different measurement techniques in this comparison agree to within +/-10% at almost all altitudes, and in the 20 km to 45 km region most agreed within +/-5%. The results show that the current generation of lidars are capable of accurate measurement of the ozone profile to a maximum altitude of 50 km. SAGE agreed well with both lidar and balloon-sonde down to at least 17 km. The ground-based microwave measurement agreed with other measurements from 22 km to above 50 km. One minor source of disagreement continues to be the pressure-altitude conversion needed to compare a measurement of ozone density versus altitude with a measurement of ozone mixing ratio versus pressure.
Characterisation of spectrophotometers used for spectral solar ultraviolet radiation measurements.
Gröbner, J
2001-01-01
Spectrophotometers used for spectral measurements of the solar ultraviolet radiation need to be well characterised to provide accurate and reliable data. Since the characterisation and calibration are usually performed in the laboratory under conditions very different from those encountered during solar measurements, it is essential to address all issues concerned with the representativity of the laboratory characterisation with respect to the solar measurements. These include among others the instrument stability, the instrument linearity, the instrument responsivity, the wavelength accuracy, the spectral resolution, stray light rejection and the instrument dependence on ambient temperature fluctuations. These instrument parameters need to be determined often enough so that the instrument changes only marginally in the period between successive characterisations and therefore provides reliable data for the intervening period.
NASA Astrophysics Data System (ADS)
Haldren, H. A.; Perey, D. F.; Yost, W. T.; Cramer, K. E.; Gupta, M. C.
2018-05-01
A digitally controlled instrument for conducting single-frequency and swept-frequency ultrasonic phase measurements has been developed based on a constant-frequency pulsed phase-locked-loop (CFPPLL) design. This instrument uses a pair of direct digital synthesizers to generate an ultrasonically transceived tone-burst and an internal reference wave for phase comparison. Real-time, constant-frequency phase tracking in an interrogated specimen is possible with a resolution of 0.000 38 rad (0.022°), and swept-frequency phase measurements can be obtained. Using phase measurements, an absolute thickness in borosilicate glass is presented to show the instrument's efficacy, and these results are compared to conventional ultrasonic pulse-echo time-of-flight (ToF) measurements. The newly developed instrument predicted the thickness with a mean error of -0.04 μm and a standard deviation of error of 1.35 μm. Additionally, the CFPPLL instrument shows a lower measured phase error in the absence of changing temperature and couplant thickness than high-resolution cross-correlation ToF measurements at a similar signal-to-noise ratio. By showing higher accuracy and precision than conventional pulse-echo ToF measurements and lower phase errors than cross-correlation ToF measurements, the new digitally controlled CFPPLL instrument provides high-resolution absolute ultrasonic velocity or path-length measurements in solids or liquids, as well as tracking of material property changes with high sensitivity. The ability to obtain absolute phase measurements allows for many new applications than possible with previous ultrasonic pulsed phase-locked loop instruments. In addition to improved resolution, swept-frequency phase measurements add useful capability in measuring properties of layered structures, such as bonded joints, or materials which exhibit non-linear frequency-dependent behavior, such as dispersive media.
Field Assessment of Acoustic-Doppler Based Discharge Measurements
Mueller, D.S.; ,
2002-01-01
The use of equipment based on the Doppler principle for measuring water velocity and computing discharge is common within the U.S. Geological Survey (USGS). The instruments and software have changed appreciably during the last 5 years; therefore, the USGS has begun a field validation of the instruments currently (2002) available for making discharge measurements from a moving boat in streams of various sizes. Instruments manufactured by SonTek/YSI2 and RD Instruments, Inc. were used to collect discharge data at five different sites. One or more traditional discharge measurements were made by the use of a Price AA current meter and standard USGS procedures with the acoustic instruments at each site during data collection. The discharges measured with the acoustic instruments were compared with the discharges measured with Price AA meters and the current USGS stage-discharge rating for each site. The mean discharges measured by each acoustic instrument were within 5 percent of the Price AA-based measurement and (or) discharge from the stage-discharge rating. Additional analysis of the data collected indicates that the coefficient of variation of the discharge measurements consistently was less for the RD Instruments, Inc. Rio Grandes than it was for the SonTek/YSI RiverSurveyors. The bottom-tracking referenced measurement had a lower coefficient of variation than the differentially corrected global positioning system referenced measurements. It was observed that the higher frequency RiverSurveyors measured a moving bed more often than the lower frequency Rio Grandes. The detection of a moving bed caused RiverSurveyors to be consistently biased low when referenced to bottom tracking. Differentially corrected global positioning system data may be used to remove the bias observed in the bottom-tracking referenced measurements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... measurements performed in accordance with § 35.63, a licensee shall possess and use instrumentation to measure... research subject. (b) A licensee shall calibrate the instrumentation required in paragraph (a) of this...
Code of Federal Regulations, 2010 CFR
2010-01-01
... measurements performed in accordance with § 35.63, a licensee shall possess and use instrumentation to measure... research subject. (b) A licensee shall calibrate the instrumentation required in paragraph (a) of this...
Code of Federal Regulations, 2014 CFR
2014-01-01
... measurements performed in accordance with § 35.63, a licensee shall possess and use instrumentation to measure... research subject. (b) A licensee shall calibrate the instrumentation required in paragraph (a) of this...
Code of Federal Regulations, 2011 CFR
2011-01-01
... measurements performed in accordance with § 35.63, a licensee shall possess and use instrumentation to measure... research subject. (b) A licensee shall calibrate the instrumentation required in paragraph (a) of this...
Code of Federal Regulations, 2013 CFR
2013-01-01
... measurements performed in accordance with § 35.63, a licensee shall possess and use instrumentation to measure... research subject. (b) A licensee shall calibrate the instrumentation required in paragraph (a) of this...
Comparison of OH reactivity measurements in the atmospheric simulation chamber SAPHIR
NASA Astrophysics Data System (ADS)
Fuchs, Hendrik; Novelli, Anna; Rolletter, Michael; Hofzumahaus, Andreas; Pfannerstill, Eva Y.; Kessel, Stephan; Edtbauer, Achim; Williams, Jonathan; Michoud, Vincent; Dusanter, Sebastien; Locoge, Nadine; Zannoni, Nora; Gros, Valerie; Truong, Francois; Sarda-Esteve, Roland; Cryer, Danny R.; Brumby, Charlotte A.; Whalley, Lisa K.; Stone, Daniel; Seakins, Paul W.; Heard, Dwayne E.; Schoemaecker, Coralie; Blocquet, Marion; Coudert, Sebastien; Batut, Sebastien; Fittschen, Christa; Thames, Alexander B.; Brune, William H.; Ernest, Cheryl; Harder, Hartwig; Muller, Jennifer B. A.; Elste, Thomas; Kubistin, Dagmar; Andres, Stefanie; Bohn, Birger; Hohaus, Thorsten; Holland, Frank; Li, Xin; Rohrer, Franz; Kiendler-Scharr, Astrid; Tillmann, Ralf; Wegener, Robert; Yu, Zhujun; Zou, Qi; Wahner, Andreas
2017-10-01
Hydroxyl (OH) radical reactivity (kOH) has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapour, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements (limit of detection < 1 s-1 at a time resolution of 30 s to a few minutes) is higher for instruments directly detecting hydroxyl radicals, whereas the indirect comparative reactivity method (CRM) has a higher limit of detection of 2 s-1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapour or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected into the chamber to simulate urban and forested environments. Overall, the results show that the instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to reference measurements or to calculated reactivity were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds (mixing ratio of OH reactants were up to 10 ppbv). In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM measurements is most likely limited by the corrections that need to be applied to account for known effects of, for example, deviations from pseudo first-order conditions, nitrogen oxides or water vapour on the measurement. Methods used to derive these corrections vary among the different CRM instruments. Measurements taken with a flow-tube instrument combined with the direct detection of OH by chemical ionisation mass spectrometry (CIMS) show limitations in cases of high reactivity and high NO concentrations but were accurate for low reactivity (< 15 s-1) and low NO (< 5 ppbv) conditions.
Mokel, Melissa Jennifer; Shellman, Juliette M
2013-01-01
Many instruments in which religious involvement is measured often (a) contain unclear, poorly developed constructs; (b) lack methodological rigor in scale development; and (c) contain language and content culturally incongruent with the religious experiences of diverse ethnic groups. The primary aims of this review were to (a) synthesize the research on instruments designed to measure religious involvement, (b) evaluate the methodological quality of instruments that measure religious involvement, and (c) examine these instruments for conceptual congruency with African American religious involvement. An updated integrative research review method guided the process (Whittemore & Knafl, 2005). 152 articles were reviewed and 23 articles retrieved. Only 3 retained instruments were developed under methodologically rigorous conditions. All 3 instruments were congruent with a conceptual model of African American religious involvement. The Fetzer Multidimensional Measure of Religious Involvement and Spirituality (FMMRS; Idler et al., 2003) was found to have favorable characteristics. Further examination and psychometric testing is warranted to determine its acceptability, readability, and cultural sensitivity in an African American population.
Balloon and surface UV radiation measurements with the NILU-CUBE instrument
NASA Astrophysics Data System (ADS)
Kylling, A.; Danielsen, T.; Webb, A.; Blumthaler, M.; Schreder, J.
2003-04-01
The NILU-CUBE instrument measures the irradiance on the six faces of a cube. On each face the radiation is measured at 312~nm and 340~nm with a bandwidth of approximately 10~nm at full width half maximum. The instrument is designed to be flown as part of balloon payloads. It may also readily be operated on the ground. The instrument and its characteristics are presented and the calibration procedure outlined. Photodissociation rates derived from measurements made during a twilight stratospheric balloon flight from Gap-Tallard, France, are presented. From two hot-air balloon flights over East-Anglia, England, measurements by the instrument were used to derive the surface albedo. Finally, surface measurements are used to describe the incoming irradiance on vertical and horizontal surfaces. All measurements are compared with model simulations.
White Paper on SBUV/2 Solar Irradiance Measurements
NASA Technical Reports Server (NTRS)
Hilsenrath, Ernest; DeLand, Matthew T.; Cebula, Richard P.
1996-01-01
The importance of solar irradiance measurements by the Solar Backscatter Ultraviolet, Model 2 (SBUV/2) instruments on NOAA's operational satellites is described. These measurements are necessary accurately monitor the long-term changes in the global column ozone amount, the altitude distribution of ozone in the upper stratosphere, and the degree to which ozone changes are caused by anthropogenic sources. Needed to accomplish these goals are weekly solar irradiance measurements at the operational ozone wavelengths, daily measurements of the Mg II proxy index, instrument-specific Mg II scale factors, and daily measurements of the solar spectral irradiance at photochemically important wavelengths. Two solar measurement schedules are provided: (1) a baseline schedule for all instruments except the NOAA-14 instrument and (2) a modified schedule for the NOAA-14 SBUV/2 instrument. This latter schedule is needed due to the NOAA-14 grating drive problems.
Li, Honghe; Ding, Ning; Zhang, Yuanyuan; Liu, Yang; Wen, Deliang
2017-01-01
Over the last three decades, various instruments were developed and employed to assess medical professionalism, but their measurement properties have yet to be fully evaluated. This study aimed to systematically evaluate these instruments' measurement properties and the methodological quality of their related studies within a universally acceptable standardized framework and then provide corresponding recommendations. A systematic search of the electronic databases PubMed, Web of Science, and PsycINFO was conducted to collect studies published from 1990-2015. After screening titles, abstracts, and full texts for eligibility, the articles included in this study were classified according to their respective instrument's usage. A two-phase assessment was conducted: 1) methodological quality was assessed by following the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist; and 2) the quality of measurement properties was assessed according to Terwee's criteria. Results were integrated using best-evidence synthesis to look for recommendable instruments. After screening 2,959 records, 74 instruments from 80 existing studies were included. The overall methodological quality of these studies was unsatisfactory, with reasons including but not limited to unknown missing data, inadequate sample sizes, and vague hypotheses. Content validity, cross-cultural validity, and criterion validity were either unreported or negative ratings in most studies. Based on best-evidence synthesis, three instruments were recommended: Hisar's instrument for nursing students, Nurse Practitioners' Roles and Competencies Scale, and Perceived Faculty Competency Inventory. Although instruments measuring medical professionalism are diverse, only a limited number of studies were methodologically sound. Future studies should give priority to systematically improving the performance of existing instruments and to longitudinal studies.
Xie, X S; Zhang, M; Zheng, Y D; Du, X Y; Qi, C
2016-06-20
To investigate the influence of two positions for measuring instrument adapter on the measurement of hand-transmitted vibration in grinding machine using the intraclass correlation coefficient (ICC) of reliability assessment index, and to provide a basis for studies on the measurement standard for hand-transmitted vibration. With reference to the measurement standard for hand-transmitted vibration ISO 5349 Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-Part 1: General requirements and Mechanical vibration-Measurement and evaluation of human exposure to hand-transmitted vibration-Part 2: Practical guidance for measurement at the workplace, the domestic AWA5936 hand-transmitted vibration measuring instrument and SVAN-106 hand-transmitted vibration measuring instrument from Poland were used to measure hand-transmitted vibration in 3 workers for grinding machine in a foundry for 5 days continuously from September to October, 2014, and Y-axis data were recorded and compared. In worker A, the "T" -shaped adapter had a significantly higher mean Y-axis accelerated speed effective value than the "O" -shaped adapter [4.34 m/s(2) (95%CI 4.05(-)4.63) vs 2.32 m/s(2) (95%CI 2.27~2.38) , t=13.781, P<0.01]. In workers B and C, AWA5936 "U" -shaped adapter (placed at the position of the handle of grinding machine) had lower degrees of data variation of 12.55% and 15.77%, respectively, suggesting good data stability. The measurement results showed significant differences across different positions of adapter (P<0.01) and between all adapters except "O" -shaped and line-shaped adapters (all P<0.01) , while the measurement results showed no significant differences between the "O" -shaped and line-shaped adapters (P>0.01). The comparison of the measurement results of AWA5936 vibration measuring instrument with an "U" -shaped adapter and SVAN-106 vibration measuring instrument with an "S" -shaped adapter showed an ICC of >0.80 (ICC=0.82) , while the comparison of the measurement results of AWA5936 vibration measuring instrument with an "O" -shaped adapter and SVAN-106 vibration measuring instrument showed an ICC of <0.40. SVAN-106 vibration measuring instrument with an "S" -shaped adapter placed at the palm and AWA5936 vibration measuring instrument with an "U" -shaped adapter placed at the handle of grinding machine can give comparable measurement results with good reliability.
Guide to measurement of winds with instrumented aircraft
NASA Technical Reports Server (NTRS)
Frost, Walter; Paige, Terry S.; Nelius, Andrew E.
1991-01-01
Aircraft measurement techniques are reviewed. Review of past and present applications of instrument aircraft to atmospheric observations is presented. Questions to be answered relative to measuring mean wind profiles as contrasted to turbulence measurements are then addressed. Requirements of instrumentation and accuracy, data reduction, data acquisition, and theoretical and certainty analysis are considered.
Heinl, Daniel; Prinsen, Cecilia A C; Drucker, Aaron M; Ofenloch, Robert; Humphreys, Rosemary; Sach, Tracey; Flohr, Carsten; Apfelbacher, Christian
2016-02-09
Eczema is a common chronic or chronically relapsing, inflammatory skin disease that exerts a substantial negative impact on quality of life (QoL). The Harmonising Outcome Measures for Eczema (HOME) initiative has used a consensus-based process which identified QoL as one of the four core outcome domains to be assessed in all eczema clinical trials. A number of measurement instruments exist to measure QoL in infants, children, and adolescents with eczema, and there is a great variability in both content and quality of the instruments used. Therefore, the objective of the proposed research is to comprehensively and systematically assess the measurement properties of the existing measurement instruments that were developed and/or validated for the measurement of patient-reported QoL in infants, children, and adolescents with eczema. This study is a systematic review of the measurement properties of patient-reported measures of QoL developed and/or validated for infants, children, and adolescents with eczema. A systematic literature search will be carried out in MEDLINE via PubMed and EMBASE using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing, or comparing measurement properties of QoL instruments for infants, children, and adolescents with eczema. Two reviewers will independently perform eligibility assessment and data abstraction. Evidence tables will be used to record study characteristics, instrument characteristics, measurement properties, and interpretability. The adequacy of the measurement properties will be assessed using predefined criteria. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist will be used to evaluate the methodological quality of included studies. A best evidence synthesis will be undertaken if more than one study has examined a particular measurement property. The proposed systematic review will yield a comprehensive assessment of measurement properties of existing QoL instruments in infants, children, and adolescents with eczema. The results will serve as a basis to recommend a QoL measurement instrument for infants, one for children, and one for adolescents for use in future clinical trials. PROSPERO CRD42015023483.
40 CFR 1065.205 - Performance specifications for measurement instruments.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...
40 CFR 1065.205 - Performance specifications for measurement instruments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...
40 CFR 1065.205 - Performance specifications for measurement instruments.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...
40 CFR 1065.205 - Performance specifications for measurement instruments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Performance specifications for measurement instruments. 1065.205 Section 1065.205 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments § 1065.205 Performance...
Instrument performance and simulation verification of the POLAR detector
NASA Astrophysics Data System (ADS)
Kole, M.; Li, Z. H.; Produit, N.; Tymieniecka, T.; Zhang, J.; Zwolinska, A.; Bao, T. W.; Bernasconi, T.; Cadoux, F.; Feng, M. Z.; Gauvin, N.; Hajdas, W.; Kong, S. W.; Li, H. C.; Li, L.; Liu, X.; Marcinkowski, R.; Orsi, S.; Pohl, M.; Rybka, D.; Sun, J. C.; Song, L. M.; Szabelski, J.; Wang, R. J.; Wang, Y. H.; Wen, X.; Wu, B. B.; Wu, X.; Xiao, H. L.; Xiong, S. L.; Zhang, L.; Zhang, L. Y.; Zhang, S. N.; Zhang, X. F.; Zhang, Y. J.; Zhao, Y.
2017-11-01
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
A Critical Review of Instruments Measuring Breastfeeding Attitudes, Knowledge, and Social Support.
Casal, Corrine S; Lei, Ann; Young, Sera L; Tuthill, Emily L
2017-02-01
Breastfeeding provides beneficial health outcomes for infants and their mothers, and increasing its practice is a national priority in many countries. Despite increasing support to exclusively breastfeed, the prevalence at 6 months remains low. Breastfeeding behavior is influenced by a myriad of determinants, including breastfeeding attitudes, knowledge, and social support. Effective measurement of these determinants is critical to provide optimal support for women throughout the breastfeeding period. However, there are a multitude of available instruments measuring these constructs, which makes identification of an appropriate instrument challenging. Research aim: Our aim was to identify and critically examine the existing instruments measuring breastfeeding attitudes, knowledge, and social support. A total of 16 instruments was identified. Each instrument's purpose, theoretical underpinnings, and validity were analyzed. An overview, validation and adaptation for use in other settings was assessed for each instrument. Depth of reporting and validation testing differed greatly between instruments. Content, construct, and predictive validity were present for most but not all scales. When selecting and adapting instruments, attention should be paid to domains within the scale, number of items, and adaptation.
A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campos, E; Sisterson, Douglas
The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess,more » and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. Note that some of the instrument observations require mathematical algorithms (retrievals) to convert a measured engineering variable into a useful geophysical measurement. While those types of retrieval measurements are identified, this study does not address particular methods for retrieval uncertainty. As well, the ARM Facility also provides engineered data products, or value-added products (VAPs), based on multiple instrument measurements. This study does not include uncertainty estimates for those data products. We propose here that a total measurement uncertainty should be calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). The study will not expand on methods for computing these uncertainties. Instead, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available in the ARM community through the ARM instrument mentors and their ARM instrument handbooks. As a result, this study will address the first steps towards reporting ARM measurement uncertainty: 1) identifying how the uncertainty of individual ARM measurements is currently expressed, 2) identifying a consistent approach to measurement uncertainty, and then 3) reclassifying ARM instrument measurement uncertainties in a common framework.« less
A review of instruments developed to measure food neophobia.
Damsbo-Svendsen, Marie; Frøst, Michael Bom; Olsen, Annemarie
2017-06-01
Food choices are influenced by an individual's attitude towards foods. Food neophobia may be associated with less variety of diets, inadequate nutrient intake and high product failure rate for new food products entering the market. To quantify the extent of these challenges, instruments to measure the food neophobia in different target groups are needed. Several such instruments with significantly different measurement outcomes and procedures have been developed. This review provides an overview and discusses strengths and weaknesses of these instruments. We evaluate strengths and weaknesses of previously developed instruments to measure neophobia and willingness to try unfamiliar foods. Literature was searched through the databases Web of Science and Google Scholar. We identified 255 studies concerning neophobia and willingness to try unfamiliar foods. Of these, 13 studies encompassing 13 instruments to measure neophobia and willingness to try unfamiliar foods were included in the review. Results are summarized and evaluated with a narrative approach. In the 13 instruments to assess neophobia and willingness to try unfamiliar foods, 113 to 16.644 subjects aged 2-65 years were involved, scales with 3-7 response categories were used and behavioral validation tests were included in 6 studies. Several instruments to measure neophobia and willingness to try unfamiliar foods exist. We recommend selecting one or more among the 13 instruments reviewed in this paper to assess relevant aspects of neophobia. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Robinson, Karen A; Davis, Wesley E; Dinglas, Victor D; Mendez-Tellez, Pedro A; Rabiee, Anahita; Sukrithan, Vineeth; Yalamanchilli, Ramakrishna; Turnbull, Alison E; Needham, Dale M
2017-02-01
There is a growing number of studies evaluating the physical, cognitive, mental health, and health-related quality of life (HRQOL) outcomes of adults surviving critical illness. However, there is little consensus on the most appropriate instruments to measure these outcomes. To inform the development of such consensus, we conducted a systematic review of the performance characteristics of instruments measuring physical, cognitive, mental health, and HRQOL outcomes in adult intensive care unit (ICU) survivors. We searched PubMed, Embase, PsycInfo, Cumulative Index of Nursing and Allied Health Literature, and The Cochrane Library in March 2015. We also conducted manual searches of reference lists of eligible studies and relevant review articles. Two people independently selected studies, completed data abstraction, and assessed the quality of eligible studies using the COnsensus-based Standards for the selection of health Measurement Instruments (COSMIN) initiative checklist. We identified 20 studies which explicitly evaluated measurement properties for 21 different instruments assessing outcomes in ICU survivors. Eleven of the instruments assessed quality of life, with few instruments assessing other domains. Of the nine measurement properties evaluated on the COSMIN checklist, six were assessed in <10% of the evaluations. Overall quality of eligible studies was generally poor to fair based on the COSMIN checklist. Although an increasing number of studies measure physical, cognitive, mental health, and HRQOL outcomes in adult ICU survivors, data on the measurement properties of such instruments are sparse and generally of poor to fair quality. Empirical analyses evaluating the performance of instruments in adult ICU survivors are needed to advance research in this field. Copyright © 2016 Elsevier Inc. All rights reserved.
Higs-instrument: design and demonstration of a high performance gas concentration imager
NASA Astrophysics Data System (ADS)
Verlaan, A. L.; Klop, W. A.; Visser, H.; van Brug, H.; Human, J.
2017-09-01
Climate change and environmental conditions are high on the political agenda of international governments. Laws and regulations are being setup all around the world to improve the air quality and to reduce the impact. The growth of a number of trace gasses, including CO2, Methane and NOx are especially interesting due to their environmental impact. The regulations made are being based on both models and measurements of the trend of those trace gases over the years. Now the regulations are in place also enforcement and therewith measurements become more and more important. Instruments enabling high spectral and spatial resolution as well as high accurate measurements of trace gases are required to deliver the necessary inputs. Nowadays those measurements are usually performed by space based spectrometers. The requirement for high spectral resolution and measurement accuracy significantly increases the size of the instruments. As a result the instrument and satellite becomes very expensive to develop and to launch. Specialized instruments with a small volume and the required performance will offer significant advantages in both cost and performance. Huib's Innovative Gas Sensor (HIGS, named after its inventor Huib Visser), currently being developed at TNO is an instrument that achieves exactly that. Designed to measure only a single gas concentration, opposed to deriving it from a spectrum, it achieves high performance within a small design volume. The instrument enables instantaneous imaging of the gas distribution of the selected gas. An instrument demonstrator has been developed for NO2 detection. Laboratory measurements proved the measurement technique to be successful. An on-sky measurement campaign is in preparation. This paper addresses both the instrument design as well as the demonstrated performances.
Eriks-Hoogland, Inge E; Brinkhof, Martin W G; Al-Khodairy, Abdul; Baumberger, Michael; Brechbühl, Jörg; Curt, Armin; Mäder, Mark; Stucki, Gerold; Post, Marcel W M
2011-11-01
The aims of this study were to provide a selection of biomedical domains based on the comprehensive International Classification of Functioning, Disability, and Health (ICF) core sets for spinal cord injury (SCI) and to present an overview of the corresponding measurement instruments. Based on the Biomedical Domain Set, the SCI literature, the International Spinal Cord Society international data sets, and the Spinal Cord Injury Rehabilitation Evidence project publications were used to derive category specifications for use in SCI research. Expert opinion was used to derive a priority selection. The same sources were used to determine candidate measurement instruments for the specification of body functions and body structures using an example, and guiding principles were applied to select the most appropriate biomedical measurement instrument(s) for use in an SCI research project. Literature searches were performed for 41 second-level ICF body functions categories and for four second-level ICF body structures categories. For some of these categories, only a few candidate measurement instruments were found with limited variation in the type of measurement instruments. An ICF-based measurement set for biomedical aspects of functioning with SCI was established. For some categories of the ICF core sets for SCI, there is a need to develop measurement instruments.
The quality of instruments to assess the process of shared decision making: A systematic review
Bomhof-Roordink, Hanna; Smith, Ian P.; Scholl, Isabelle; Stiggelbout, Anne M.; Pieterse, Arwen H.
2018-01-01
Objective To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. Methods In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. Results We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Conclusions Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument’s content and characteristics such as the perspective that they assess. We recommend refinement and validation of existing instruments, and the use of COSMIN-guidelines to help guarantee high-quality evaluations. PMID:29447193
Development of a surface topography instrument for automotive textured steel plate
NASA Astrophysics Data System (ADS)
Wang, Zhen; Wang, Shenghuai; Chen, Yurong; Xie, Tiebang
2010-08-01
The surface topography of automotive steel plate is decisive to its stamping, painting and image clarity performances. For measuring this kind of surface topography, an instrument has been developed based on the principle of vertical scanning white light microscopy interference principle. The microscopy interference system of this instrument is designed based on the structure of Linnik interference microscopy. The 1D worktable of Z direction is designed and introduced in details. The work principle of this instrument is analyzed. In measuring process, the interference microscopy is derived as a whole and the measured surface is scanned in vertical direction. The measurement accuracy and validity is verified by templates. Surface topography of textured steel plate is also measured by this instrument.
Challenging Residual Contamination of Instruments for Robotic Surgery in Japan.
Saito, Yuhei; Yasuhara, Hiroshi; Murakoshi, Satoshi; Komatsu, Takami; Fukatsu, Kazuhiko; Uetera, Yushi
2017-02-01
BACKGROUND Recently, robotic surgery has been introduced in many hospitals. The structure of robotic instruments is so complex that updating their cleaning methods is a challenge for healthcare professionals. However, there is limited information on the effectiveness of cleaning for instruments for robotic surgery. OBJECTIVE To determine the level of residual contamination of instruments for robotic surgery and to develop a method to evaluate the cleaning efficacy for complex surgical devices. METHODS Surgical instruments were collected immediately after operations and/or after in-house cleaning, and the level of residual protein was measured. Three serial measurements were performed on instruments after cleaning to determine the changes in the level of contamination and the total amount of residual protein. The study took place from September 1, 2013, through June 30, 2015, in Japan. RESULTS The amount of protein released from robotic instruments declined exponentially. The amount after in-house cleaning was 650, 550, and 530 µg/instrument in the 3 serial measurements. The overall level of residual protein in each measurement was much higher for robotic instruments than for ordinary instruments (P<.0001). CONCLUSIONS Our data demonstrated that complete removal of residual protein from surgical instruments is virtually impossible. The pattern of decline differed depending on the instrument type, which reflected the complex structure of the instruments. It might be necessary to establish a new standard for cleaning using a novel classification according to the structural complexity of instruments, especially for those for robotic surgery. Infect Control Hosp Epidemiol 2017;38:143-146.
Instruments to measure cancer management knowledge of rural health care providers.
Elliott, T E; Regal, R R; Renier, C M; Crouse, B J; Gangeness, D E; Pharmd; Elliott, B A; Witrak, M
2001-01-01
Instruments to measure cancer management knowledge of rural physicians, nurses, and pharmacists were needed to evaluate the effect of an educational intervention. Since such instruments did not exist, the authors designed and validated a new instrument for each discipline. The design and validation process for these instruments are described. These three instruments were shown to be practical and to have high content and construct validity. Content validation demonstrated that all items were rated as essential or useful by 90% or more of the respondents. Construct validation show highly significant differences in mean scores among several levels of learners and practitioners as expected. These instruments may be useful to other investigators for measuring cancer management knowledge of rural physicians, nurses, and pharmacists.
Self-contained instrument for measuring subterranean tunnel wall deflection
Rasmussen, Donald Edgar; Hof, Jr., Peter John
1978-01-01
The deflection of a subterranean tunnel is measured with a rod-like, self-contained instrument that is adapted to be inserted into a radially extending bore of the tunnel adjacent an end of the tunnel where the tunnel is being dug. One end of the instrument is anchored at the end of the bore remote from the tunnel wall, while the other end of the intrument is anchored adjacent the end of the wall in proximity to the tunnel wall. The two ends of the instrument are linearly displaceable relative to each other; the displacement is measured by a transducer means mounted on the instrument. Included in the instrument is a data storage means including a paper tape recorder periodically responsive to a parallel binary signal indicative of the measured displacement.
Low-energy particle experiments-electron analyzer (LEPe) onboard the Arase spacecraft
NASA Astrophysics Data System (ADS)
Kazama, Yoichi; Wang, Bo-Jhou; Wang, Shiang-Yu; Ho, Paul T. P.; Tam, Sunny W. Y.; Chang, Tzu-Fang; Chiang, Chih-Yu; Asamura, Kazushi
2017-12-01
In this report, we describe the low-energy electron instrument LEPe (low-energy particle experiments-electron analyzer) onboard the Arase (ERG) spacecraft. The instrument measures a three-dimensional distribution function of electrons with energies of ˜ 19 eV-19 keV. Electrons in this energy range dominate in the inner magnetosphere, and measurement of such electrons is important in terms of understanding the magnetospheric dynamics and wave-particle interaction. The instrument employs a toroidal tophat electrostatic energy analyzer with a passive 6-mm aluminum shield. To minimize background radiation effects, the analyzer has a background channel, which monitors counts produced by background radiation. Background counts are then subtracted from measured counts. Electronic components are radiation tolerant, and 5-mm-thick shielding of the electronics housing ensures that the total dose is less than 100 kRad for the one-year nominal mission lifetime. The first in-space measurement test was done on February 12, 2017, showing that the instrument functions well. On February 27, the first all-instrument run test was done, and the LEPe instrument measured an energy dispersion event probably related to a substorm injection occurring immediately before the instrument turn-on. These initial results indicate that the instrument works fine in space, and the measurement performance is good for science purposes.[Figure not available: see fulltext.
Informal caregiving in COPD: A systematic review of instruments and their measurement properties.
Cruz, Joana; Marques, Alda; Machado, Ana; O'Hoski, Sachi; Goldstein, Roger; Brooks, Dina
2017-07-01
Increasing symptoms and activity restriction associated with COPD progression greatly impact on the lives of their informal caregivers, who play a vital role in maintaining their health. An understanding of this impact is important for clinicians to support caregivers and maintain a viable patient environment at home. This systematic review aimed to identify the instruments commonly used to assess informal caregiving in COPD and describe their measurement properties in this population. Searches were conducted in PubMed, Scopus, Web of Science, CINAHL and PsycINFO and in references of key articles, until November 2016 (PROSPERO: CRD42016041401). Instruments used to assess the impact of COPD on caregivers were identified and their properties described. Quality of studies was rated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Quality of the measurement properties of instruments was rated as 'positive', 'negative' or 'indeterminate'. Patients cared for, had moderate to very severe COPD and the sample of caregivers ranged from 24 to 406. Thirty-five instruments were used in fifty studies to assess caregivers' psychological status and mood (9 instruments), burden/distress (12 instruments), quality of life (5 instruments) or other (9 instruments). Eighteen studies assessed the measurement properties of 21 instruments, most commonly hypothesis testing (known validity) and internal consistency. Study quality varied from 'poor' to 'fair' and with many properties rated as 'indeterminate'. Although several instruments have been used to assess the impact of COPD on caregivers, an increased understanding of their properties is needed before their widespread implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ounsi, Hani F; Franciosi, Giovanni; Paragliola, Raffaele; Al-Hezaimi, Khalid; Salameh, Ziad; Tay, Franklin R; Ferrari, Marco; Grandini, Simone
2011-06-01
The shaping capacity of nickel-titanium (NiTi) rotary instruments is often assessed by photographic or micro-computed tomography (micro-CT) measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-CT measurements and to assess if the repeated use of NiTi instruments affected the shape of canal preparation. Ten new sets of ProTaper Universal instruments (Dentsply-Maillefer, Ballaigues, Switzerland) were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented the first to sixth use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm(2)) were calculated using AutoCAD (Autodesk Inc, San Rafael, CA). The volumes of the same prepared canals were measured using micro-CT (mm(3)). Statistical analysis was performed to detect differences between photographic and volumetric measurements and differences between uses. Two-way repeated-measures analysis of variance revealed significant differences between groups (P < .001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL measurements (P < .001) and micro-CT and MD measurements (P=.001). Significant differences were also noted between uses. Within the limitations of the present study, micro-CT scanning is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Daigneault, Pierre-Marc; Jacob, Steve; Tremblay, Joel
2012-01-01
Background: Stakeholder participation is an important trend in the field of program evaluation. Although a few measurement instruments have been proposed, they either have not been empirically validated or do not cover the full content of the concept. Objectives: This study consists of a first empirical validation of a measurement instrument that…
ERIC Educational Resources Information Center
Cowan, David T.; Fitzpatrick, Joanne M.; Roberts, Julia D.; While, Alison E.
2004-01-01
This paper discusses the sensitivity of instruments used to measure knowledge and attitudes toward older people. Existing standardized measurement instruments are reviewed, including a detailed examination of Palmore's Facts on Ageing Quiz (FAQ). A recent study conducted by the research team into the knowledge and attitudes of support workers (n =…
ERIC Educational Resources Information Center
Cowan, David T.; Fitzpatrick, Joanne M.; Roberts, Julia D.; While, Alison E.
2004-01-01
This paper discusses the sensitivity of instruments used to measure knowledge and attitudes toward older people. Existing standardized measurement instruments are reviewed, including a detailed examination of Palmore's Facts on Ageing Quiz (FAQ). A recent study conducted by the research team into the knowledge and attitudes of support workers…
Measuring the Sensitivity and Construct Validity of 6 Utility Instruments in 7 Disease Areas.
Richardson, Jeff; Iezzi, Angelo; Khan, Munir A; Chen, Gang; Maxwell, Aimee
2016-02-01
Health services that affect quality of life (QoL) are increasingly evaluated using cost utility analyses (CUA). These commonly employ one of a small number of multiattribute utility instruments (MAUI) to assess the effects of the health service on utility. However, the MAUI differ significantly, and the choice of instrument may alter the outcome of an evaluation. The present article has 2 objectives: 1) to compare the results of 3 measures of the sensitivity of 6 MAUI and the results of 6 tests of construct validity in 7 disease areas and 2) to rank the MAUI by each of the test results in each disease area and by an overall composite index constructed from the tests. Patients and the general public were administered a battery of instruments, which included the 6 MAUI, disease-specific QoL instruments (DSI), and 6 other comparator instruments. In each disease area, instrument sensitivity was measured 3 ways: by the unadjusted mean difference in utility between public and patient groups, by the value of the effect size, and by the correlation between MAUI and DSI scores. Content and convergent validity were tested by comparison of MAUI utilities and scores from the 6 comparator instruments. These included 2 measures of health state preferences, measures of subjective well-being and capabilities, and generic measures of physical and mental QoL derived from the SF-36. The apparent sensitivity of instruments varied significantly with the measurement method and by disease area. Validation test results varied with the comparator instruments. Notwithstanding this variability, the 15D, AQoL-8D, and the SF-6D generally achieved better test results than the QWB and EQ-5D-5L. © The Author(s) 2015.
White, Isabella D; Sangha, Amrit; Lucas, Grace; Wiseman, Theresa
2016-12-01
Practitioners and researchers require an outcome measure that accurately identifies the range of common treatment-induced changes in sexual function and well-being experienced by women after cervical or endometrial cancer. This systematic review critically appraised the measurement properties and clinical utility of instruments validated for the measurement of female sexual dysfunction (FSD) in this clinical population. A bibliographic database search for questionnaire development or validation papers was completed and methodological quality and measurement properties of selected studies rated using the Consensus-based Standards for the selection of health Measurement Instrument (COSMIN) checklist. 738 articles were screened, 13 articles retrieved for full text assessment and 7 studies excluded, resulting in evaluation of 6 papers; 2 QoL and 4 female sexual morbidity measures. Five of the six instruments omitted one or more dimension of female sexual function and only one instrument explicitly measured distress associated with sexual changes as per DSM V (APA 2013) diagnostic criteria. None of the papers reported measurement error, responsiveness data was available for only two instruments, three papers failed to report on criterion validity, and test-retest reliability reporting was inconsistent. Heterosexual penile-vaginal intercourse remains the dominant sexual activity focus for sexual morbidity PROMS terminology and instruments lack explicit reference to solo or non-coital sexual expression or validation in a non-heterosexual sample. Four out of six instruments included mediating treatment or illness items such as vaginal changes, menopause or altered body image. Findings suggest that the Female Sexual Function Index (FSFI) remains the most robust sexual morbidity outcome measure, for research or clinical use, in sexually active women treated for cervical or endometrial cancer. Development of an instrument that measures sexual dysfunction in women who are infrequently/not sexually active due to treatment consequences is still required to identify women in need of sexual rehabilitation. Copyright © 2016 Elsevier Inc. All rights reserved.
A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report: Updated in 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sisterson, Douglas
The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. ARM currently provides data and supporting metadata (information about the data or data quality) to its users through several sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, ARM relies on Instrument Mentors and the ARM Data Quality Office to ensure, assess, and report measurement quality. Therefore, anmore » easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. This report is a continuation of the work presented by Campos and Sisterson (2015) and provides additional uncertainty information from instruments not available in their report. As before, a total measurement uncertainty has been calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). This study will not expand on methods for computing these uncertainties. As before, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available to the ARM community through the ARM Instrument Mentors and their ARM instrument handbooks. This study continues the first steps towards reporting ARM measurement uncertainty as: (1) identifying how the uncertainty of individual ARM measurements is currently expressed, (2) identifying a consistent approach to measurement uncertainty, and then (3) reclassifying ARM instrument measurement uncertainties in a common framework.« less
40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Gas meter or flow instrumentation... instrumentation calibration; particulate, methanol, and formaldehyde measurement. (a) Sampling for particulate, methanol and formaldehyde emissions requires the use of gas meters or flow instrumentation to determine...
40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Gas meter or flow instrumentation... instrumentation calibration; particulate, methanol, and formaldehyde measurement. (a) Sampling for particulate, methanol and formaldehyde emissions requires the use of gas meters or flow instrumentation to determine...
40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... instrumentation calibration; particulate, methanol, and formaldehyde measurement. (a) Sampling for particulate, methanol and formaldehyde emissions requires the use of gas meters or flow instrumentation to determine...
40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...
40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Gas meter or flow instrumentation... instrumentation calibration; particulate, methanol, and formaldehyde measurement. (a) Sampling for particulate, methanol and formaldehyde emissions requires the use of gas meters or flow instrumentation to determine...
A Comprehensive Radial Velocity Error Budget for Next Generation Doppler Spectrometers
NASA Technical Reports Server (NTRS)
Halverson, Samuel; Ryan, Terrien; Mahadevan, Suvrath; Roy, Arpita; Bender, Chad; Stefansson, Guomundur Kari; Monson, Andrew; Levi, Eric; Hearty, Fred; Blake, Cullen;
2016-01-01
We describe a detailed radial velocity error budget for the NASA-NSF Extreme Precision Doppler Spectrometer instrument concept NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy). Such an instrument performance budget is a necessity for both identifying the variety of noise sources currently limiting Doppler measurements, and estimating the achievable performance of next generation exoplanet hunting Doppler spectrometers. For these instruments, no single source of instrumental error is expected to set the overall measurement floor. Rather, the overall instrumental measurement precision is set by the contribution of many individual error sources. We use a combination of numerical simulations, educated estimates based on published materials, extrapolations of physical models, results from laboratory measurements of spectroscopic subsystems, and informed upper limits for a variety of error sources to identify likely sources of systematic error and construct our global instrument performance error budget. While natively focused on the performance of the NEID instrument, this modular performance budget is immediately adaptable to a number of current and future instruments. Such an approach is an important step in charting a path towards improving Doppler measurement precisions to the levels necessary for discovering Earth-like planets.
Comparison of OH Reactivity Instruments in the Atmosphere Simulation Chamber SAPHIR.
NASA Astrophysics Data System (ADS)
Fuchs, H.; Novelli, A.; Rolletter, M.; Hofzumahaus, A.; Pfannerstill, E.; Edtbauer, A.; Kessel, S.; Williams, J.; Michoud, V.; Dusanter, S.; Locoge, N.; Zannoni, N.; Gros, V.; Truong, F.; Sarda Esteve, R.; Cryer, D. R.; Brumby, C.; Whalley, L.; Stone, D. J.; Seakins, P. W.; Heard, D. E.; Schoemaecker, C.; Blocquet, M.; Fittschen, C. M.; Thames, A. B.; Coudert, S.; Brune, W. H.; Batut, S.; Tatum Ernest, C.; Harder, H.; Elste, T.; Bohn, B.; Hohaus, T.; Holland, F.; Muller, J. B. A.; Li, X.; Rohrer, F.; Kubistin, D.; Kiendler-Scharr, A.; Tillmann, R.; Andres, S.; Wegener, R.; Yu, Z.; Zou, Q.; Wahner, A.
2017-12-01
Two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016 to compare hydroxyl (OH) radical reactivity (kOH) measurements. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapor, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements is higher for instruments directly detecting hydroxyl radicals (OH), whereas the indirect Comparative Reactivity Method (CRM) has a higher limit of detection of 2s-1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapor or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected in the chamber to simulate urban and forested environments. Overall, the results show that instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to the reference were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds. In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM measurements is most likely limited by the corrections that need to be applied in order to account for known effects of, for example, deviations from pseudo-first order conditions, nitrogen oxides or water vapor on the measurement. Methods to derive these corrections vary among the different CRM instruments. Measurements by a flow-tube instrument combined with the direct detection of OH by chemical ionization mass spectrometry (CIMS) show limitations, but were accurate for low reactivity (< 15s -1) and low NO (< 5 ppbv) conditions.
Al Sayah, Fatima; Williams, Beverly; Johnson, Jeffrey A
2013-02-01
To identify instruments used to measure health literacy and numeracy in people with diabetes; evaluate their use, measurement scope, and properties; discuss their strengths and weaknesses; and propose the most useful, reliable, and applicable measure for use in research and practice settings. A systematic literature review was conducted to identify the instruments. Nutbeam's domains of health literacy and a diabetes health literacy skill set were used to evaluate the measurement scope of the identified instruments and to evaluate their applicability in people with diabetes. Fifty-six studies were included, from which one diabetes-specific (LAD) and eight generic measures of health literacy (REALM, REALM-R, TOFHLA, s-TOFHLA, NVS, 3-brief SQ, 3-level HL Scale, SILS) and one diabetes-specific (DNT) and two generic measures of numeracy (SNS, WRAT) were identified. These instruments were categorized into direct measures, that is, instruments that assess the performance of individuals on health literacy skills and indirect measures that rely on self-report of these skills. The most commonly used instruments measure selective domains of health literacy, focus mainly on reading and writing skills, and do not address other important skills such as verbal communication, health care system navigation, health-related decision making, and numeracy. The structure, mode, and length of administration and measurement properties were found to affect the applicability of these instruments in clinical and research settings. Indirect self- or clinician-administered measures are the most useful in both clinical and research settings. This review provides an evaluation of available health literacy measures and guidance to practitioners and researchers for selecting the appropriate measures for use in clinical settings and research applications.
NASA Technical Reports Server (NTRS)
Weinstock, E. M.; Smith, J. B.; Sayres, D.; Pittman, J. V.; Allen, N.; Demusz, J.; Greenberg, M.; Rivero, M.; Anderson, J. G.
2003-01-01
We describe an instrument mounted in a pallet on the NASA WB-57 aircraft that is designed to measure the sum of gas phase and solid phase water, or total water, in cirrus clouds. Using an isokinetic inlet, a 600-watt heater mounted directly in the flow, and Lyman-alpha photofragment fluorescence technique for detection, accurate measurements of total water have been made over almost three orders of magnitude. Isokinetic flow is achieved with an actively controlled roots pump by referencing aircraft pressure, temperature, and true air speed, together with instrument flow velocity, temperature, and pressure. During CRYSTAL FACE, the instrument operated at duct temperatures sufficiently warm to completely evaporate particles up to 150 microns diameter. In flight diagnostics, intercomparison with water measured by absorption in flight, as well as intercomparisons in clear air with water vapor measured by the Harvard water vapor instrument and the JPL infrared tunable diode laser hygrometer validate the detection sensitivity of the instrument and illustrate minimal hysteresis from instrument surfaces. The simultaneous measurement of total water and water vapor in cirrus clouds yields their ice water content.
ATLAS-3 correlative measurement opportunities with UARS and surface observations
NASA Technical Reports Server (NTRS)
Harrison, Edwin F.; Denn, Fred M.; Gibson, Gary G.
1995-01-01
The third ATmospheric Laboratory for Applications and Science (ATLAS-3) mission was flown aboard the Space Shuttle launched on November 3, 1994. The mission length was approximately 10 days and 22 hours. The ATLAS-3 Earth-viewing instruments provided a large number of measurements which were nearly coincident with observations from experiments on the Upper Atmosphere Research Satellite (UARS). Based on ATLAS-3 instrument operating schedules, simulations were performed to determine when and where correlative measurements occurred between ATLAS and UARS instruments, and between ATLAS and surface observations. Results of these orbital and instrument simulations provide valuable information for scientists to compare measurements between various instruments on the two satellites and at selected surface sites.
Field and laboratory comparison of PM10 instruments in high winds
USDA-ARS?s Scientific Manuscript database
Instruments capable of measuring PM10 (particulate matter less than or equal to 10µm in aerodynamic diameter) concentrations may vary in performance as a result of different technologies utilized in measuring PM10. Therefore, the performance of five instruments capable of measuring PM10 concentratio...
Arizona's Instrument to Measure Standards (AIMS DPA). Student Guide, Grade 8
ERIC Educational Resources Information Center
Arizona Department of Education, 2006
2006-01-01
Arizona's Instrument to Measure Standards (AIMS), a Standards-Based test, provides educators and the public with valuable information regarding the progress of Arizona's students toward mastering Arizona's reading, writing and mathematics Standards. This specific test, Arizona's Instrument to Measure Standards Dual Purpose Assessment (AIMS DPA) is…
The 2014 ASCENDS Field Campaign - a Carbon Dioxide Laser Absorption Spectrometer Perspective
NASA Astrophysics Data System (ADS)
Spiers, G. D.; Menzies, R. T.; Jacob, J. C.; Geier, S.; Fregoso, S. F.
2014-12-01
NASA's ASCENDS mission has been flying several candidate lidar instruments on board the NASA DC-8 aircraft to obtain column integrated measurements of Carbon Dioxide. Each instrument uses a different approach to making the measurement and combined they have allowed for the informed development of the ASCENDS mission measurement requirements(1). The JPL developed Carbon Dioxide Laser Absorption Spectrometer, CO2LAS is one of these instruments. The CO2LAS measures the weighted, column averaged carbon dioxide between the aircraft and the ground using a continuous-wave heterodyne technique. The instrument operates at a 2.05 micron wavelength optimized for enhancing sensitivity to boundary layer carbon dioxide. Since the 2013 field campaign the instrument has undergone significant upgrades that improve the data collection efficiency and instrument stability and has recently been re-integrated onto the NASA DC-8 for the August 2014 ASCENDS field campaign. This presentation will summarize the instrument and algorithm improvements and review the 2014 field campaign flights and preliminary results. (1) Abshire, J.B. et al., "An overview of NASA's ASCENDS Mission lidar measurement requirements", submitted to 2014 Fall AGU Conference.
Clari, Marco; Matarese, Maria; Alvaro, Rosaria; Piredda, Michela; De Marinis, Maria Grazia
2016-01-01
The use of valid and reliable instruments for assessing self-care is crucial for the evaluation of chronic obstructive pulmonary disease (COPD) management programs. The aim of this review is to evaluate the measurement properties and theoretical foundations of instruments for assessing self-care and related concepts in people with COPD. A systematic review was conducted of articles describing the development and validation of self-care instruments. The methodological quality of the measurement properties was assessed using the COSMIN checklist. Ten studies were included evaluating five instruments: three for assessing self-care and self-management and two for assessing self-efficacy. The COPD Self-Efficacy Scale was the most studied instrument, but due to poor study methodological quality, evidence about its measurement properties is inconclusive. Evidence from the COPD Self-Management Scale is more promising, but only one study tested its properties. Due to inconclusive evidence of their measurement properties, no instrument can be recommended for clinical use. Copyright © 2016 Elsevier Inc. All rights reserved.
Measuring the stringency of states' indoor tanning regulations: instrument development and outcomes.
Woodruff, Susan I; Pichon, Latrice C; Hoerster, Katherine D; Forster, Jean L; Gilmer, Todd; Mayer, Joni A
2007-05-01
We sought to describe the development of an instrument to quantify the stringency of state indoor tanning legislation in the United States, and the instrument's psychometric properties. The instrument was then used to rate the stringency of state laws. A 35-item instrument was developed. An overall stringency measure and 9 stringency subscales were developed, including one measuring minors' access to indoor tanning. Stringency measures showed good internal consistency and interrater reliability. In all, 55% of the 50 states and the District of Columbia had any indoor tanning law, and 41% had any law addressing minors' access. Oregon, Illinois, South Carolina, Florida, Indiana, Iowa, and Rhode Island had high overall stringency scores, and Texas and New Hampshire were the most restrictive with regard to minors' access. Measurement of actual enforcement of the laws was not included in this study. The instrument appears to be an easy-to-use, reliable, and valid methodology. Application of the instrument to actual laws showed that, in general, state laws are relatively weak, although there was considerable variability by state.
NASA Technical Reports Server (NTRS)
Jordan, C. E.; Anderson, B. E.; Beyersdorf, A. J.; Corr, C. A.; Dibb, J. E.; Greenslade, M. E.; Martin, R. F.; Moore, R. H.; Scheuer, E.; Shook, M. A.;
2015-01-01
We introduce a new instrument for the measurement of in situ ambient aerosol extinction over the 300-700 nm wavelength range, the Spectral Aerosol Extinction (SpEx) instrument. This measurement capability is envisioned to complement existing in situ instrumentation, allowing for simultaneous measurement of the evolution of aerosol optical, chemical, and physical characteristics in the ambient environment. In this work, a detailed description of the instrument is provided along with characterization tests performed in the laboratory. Measured spectra of NO2 and polystyrene latex spheres agreed well with theoretical calculations. Good agreement was also found with simultaneous aerosol extinction measurements at 450, 530, and 630 nm using CAPS PMex instruments in a series of 22 tests including non-absorbing compounds, dusts, soot, and black and brown carbon analogs. SpEx can more accurately distinguish the presence of brown carbon from other absorbing aerosol due to its 300 nm lower wavelength limit compared to measurements limited to visible wavelengths. In addition, the spectra obtained by SpEx carry more information than can be conveyed by a simple power law fit that is typically defined by the use of Angstrom Exponents. Future improvements aim at lowering detection limits and ruggedizing the instrument for mobile operation.
ERIC Educational Resources Information Center
Osler, James Edward, II
2016-01-01
The overall aim of this paper is to provide an epistemological rational for the measurement of intentionality. The purpose of this narrative is to identify "Intentionality" as an arena of action in the dispositional learning domain can be measured using an "Intentionality Measurement Instrument" [also referred by the acronym…
Calibration for the SAGE III/EOS instruments
NASA Technical Reports Server (NTRS)
Chu, W. P.; Mccormick, M. P.; Zawodny, J. M.; Mcmaster, L. R.
1991-01-01
The calibration plan for the SAGE III instruments for maintaining instrument performance during the Earth Observing System (EOS) mission lifetime is described. The SAGE III calibration plan consists of detailed preflight and inflight calibration on the instrument performance together with the correlative measurement program to validate the data products from the inverted satellite measurements. Since the measurement technique is primarily solar/lunar occultation, the instrument will be self-calibrating by using the sun as the calibration source during the routine operation of the instrument in flight. The instrument is designed to perform radiometric calibration of throughput, spectral, and spatial response in flight during routine operation. Spectral calibration can be performed in-flight from observation of the solar Fraunhofer lines within the spectral region from 290 to 1030 nm wavelength.
[Development of opened instrument for generating and measuring physiological signal].
Chen, Longcong; Hu, Guohu; Gao, Bin
2004-12-01
An opened instrument with liquid crystal display (LCD) for generating and measuring physiological signal is introduced in this paper. Based on a single-chip microcomputer. the instrument uses the technique of LCD screen to display signal wave and information, and it realizes man-machine interaction by keyboard. This instrument can produce not only defined signal in common use by utilizing important saved data and relevant arithmetic, but also user-defined signal. Therefore, it is open to produce signal. In addition, this instrument has strong extension because of its modularized design as computer, which has much function such as displaying, measuring and saving physiological signal, and many features such as low power consumption, small volume, low cost and portability. Hence this instrument is convenient for experiment teaching, clinic examining, maintaining of medical instrument.
Radiant Power Measuring Instrument (RPMI)
NASA Technical Reports Server (NTRS)
Rogers, R. H. (Principal Investigator)
1973-01-01
There are no author-identified significant results in this report. The radiant power measuring instrument is a rugged, hand-carried instrument which provides an ERTS investigator with a capability of obtaining radiometric measurements needed to determine solar and atmospheric parameters that affect the ERTS radiance measurements. With these parameters, ERTS data can be transformed into absolute target reflectance signatures, making accurate unambiguous interpretations possible.
Optical radiation measurements: instrumentation and sources of error.
Landry, R J; Andersen, F A
1982-07-01
Accurate measurement of optical radiation is required when sources of this radiation are used in biological research. The most difficult measurements of broadband noncoherent optical radiations usually must be performed by a highly trained specialist using sophisticated, complex, and expensive instruments. Presentation of the results of such measurement requires correct use of quantities and units with which many biological researchers are unfamiliar. The measurement process, physical quantities and units, measurement systems with instruments, and sources of error and uncertainties associated with optical radiation measurements are reviewed.
The quality of systematic reviews of health-related outcome measurement instruments.
Terwee, C B; Prinsen, C A C; Ricci Garotti, M G; Suman, A; de Vet, H C W; Mokkink, L B
2016-04-01
Systematic reviews of outcome measurement instruments are important tools for the selection of instruments for research and clinical practice. Our aim was to assess the quality of systematic reviews of health-related outcome measurement instruments and to determine whether the quality has improved since our previous study in 2007. A systematic literature search was performed in MEDLINE and EMBASE between July 1, 2013, and June 19, 2014. The quality of the reviews was rated using a study-specific checklist. A total of 102 reviews were included. In many reviews the search strategy was considered not comprehensive; in only 59 % of the reviews a search was performed in EMBASE and in about half of the reviews there was doubt about the comprehensiveness of the search terms used for type of measurement instruments and measurement properties. In 41 % of the reviews, compared to 30 % in our previous study, the methodological quality of the included studies was assessed. In 58 %, compared to 55 %, the quality of the included instruments was assessed. In 42 %, compared to 7 %, a data synthesis was performed in which the results from multiple studies on the same instrument were somehow combined. Despite a clear improvement in the quality of systematic reviews of outcome measurement instruments in comparison with our previous study in 2007, there is still room for improvement with regard to the search strategy, and especially the quality assessment of the included studies and the included instruments, and the data synthesis.
Blankers, M; Barendregt, M; Dekker, J J M
2016-01-01
In mental health care centres in the Netherlands outcome data are collected using a variety of outcome instruments. This may have implications for the comparability of outcome results between different centres. To discuss recent findings regarding the extent to which the eight instruments currently used in clinical practice report comparable results. Our study is based on a combination of literature review and empirical research. The results obtained with the eight instruments are not equivalent. Patients symptom reductions appear larger with some instruments than with others. The current practice of benchmarking in the Dutch mental health system would have greater validity if the number of different instruments would be reduced. State-of-the-art calibration studies are necessary to validate the comparability of the remaining instruments. Ideally, all mental health centres will soon use one instrument per care domain to measure treatment outcome.
Development of an Instrument to Measure Medical Students' Attitudes toward People with Disabilities
ERIC Educational Resources Information Center
Symons, Andrew B.; Fish, Reva; McGuigan, Denise; Fox, Jeffery; Akl, Elie A.
2012-01-01
As curricula to improve medical students' attitudes toward people with disabilities are developed, instruments are needed to guide the process and evaluate effectiveness. The authors developed an instrument to measure medical students' attitudes toward people with disabilities. A pilot instrument with 30 items in four sections was administered to…
Validation of an Adapted Instrument to Measure Students' Attitude towards Science
ERIC Educational Resources Information Center
Chin, Sook Fui; Lim, Hooi Lian
2016-01-01
Attitude towards science (ATS) is a major concern in science education. Although many ATS instruments have been developed, they are based on different cultural systems and having some limitations. This study aims to validate an instrument for measuring students' ATS in Malaysia context. The instrument was adapted from Test of Science-Related…
Eyles, J P; Hunter, D J; Meneses, S R F; Collins, N J; Dobson, F; Lucas, B R; Mills, K
2017-08-01
To make a recommendation on the "best" instrument to assess attitudes toward and/or capabilities regarding self-management of osteoarthritis (OA) based on available measurement property evidence. Electronic searches were performed in MEDLINE, EMBASE, CINAHL and PsychINFO (inception to 27 December 2016). Two reviewers independently rated measurement properties using the Consensus-based Standards for the selection of Health Measurement Instruments (COSMIN) 4-point scale. Best evidence synthesis was determined by considering COSMIN ratings for measurement property results and the level of evidence available for each measurement property of each instrument. Eight studies out of 5653 publications met the inclusion criteria, with eight instruments identified for evaluation: Multidimensional Health Locus of Control (MHLC), Perceived Behavioural Control (PBC), Patient Activation Measure (PAM), Educational Needs Assessment (ENAT), Stages of Change Questionnaire in Osteoarthritis (SCQOA), Effective Consumer Scale (EC-17) and Perceived Efficacy in Patient-Physician Interactions five item (PEPPI-5) and ten item scales. Measurement properties assessed for these instruments included internal consistency (k = 8), structural validity (k = 8), test-retest reliability (k = 2), measurement error (k = 1), hypothesis testing (k = 3) and cross-cultural validity (k = 3). No information was available for content validity, responsiveness or minimal important change (MIC)/minimal important difference (MID). The Dutch PEPPI-5 demonstrated the best measurement property evidence; strong evidence for internal consistency and structural validity but limited evidence for reliability and construct validity. Although PEPPI-5 was identified as having the best measurement properties, overall there is a poor level of evidence currently available concerning measurement properties of instruments to assess attitudes toward and/or capabilities regarding osteoarthritis self-management. Further well-designed studies investigating measurement properties of existing instruments are required. Copyright © 2017 Osteoarthritis Research Society International. All rights reserved.
NASA Technical Reports Server (NTRS)
Bale, S. D.; Goetz, K.; Harvey, P. R.; Turin, P.; Bonnell, J. W.; Dudok de Wit, T.; Ergun, R. E.; MacDowall, R. J.; Pulupa, M.; Choi, M. K.;
2016-01-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
Bale, S D; Goetz, K; Harvey, P R; Turin, P; Bonnell, J W; de Wit, T Dudok; Ergun, R E; MacDowall, R J; Pulupa, M; Andre, M; Bolton, M; Bougeret, J-L; Bowen, T A; Burgess, D; Cattell, C A; Chandran, B D G; Chaston, C C; Chen, C H K; Choi, M K; Connerney, J E; Cranmer, S; Diaz-Aguado, M; Donakowski, W; Drake, J F; Farrell, W M; Fergeau, P; Fermin, J; Fischer, J; Fox, N; Glaser, D; Goldstein, M; Gordon, D; Hanson, E; Harris, S E; Hayes, L M; Hinze, J J; Hollweg, J V; Horbury, T S; Howard, R A; Hoxie, V; Jannet, G; Karlsson, M; Kasper, J C; Kellogg, P J; Kien, M; Klimchuk, J A; Krasnoselskikh, V V; Krucker, S; Lynch, J J; Maksimovic, M; Malaspina, D M; Marker, S; Martin, P; Martinez-Oliveros, J; McCauley, J; McComas, D J; McDonald, T; Meyer-Vernet, N; Moncuquet, M; Monson, S J; Mozer, F S; Murphy, S D; Odom, J; Oliverson, R; Olson, J; Parker, E N; Pankow, D; Phan, T; Quataert, E; Quinn, T; Ruplin, S W; Salem, C; Seitz, D; Sheppard, D A; Siy, A; Stevens, K; Summers, D; Szabo, A; Timofeeva, M; Vaivads, A; Velli, M; Yehle, A; Werthimer, D; Wygant, J R
2016-12-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
NASA Astrophysics Data System (ADS)
Bale, S. D.; Goetz, K.; Harvey, P. R.; Turin, P.; Bonnell, J. W.; Dudok de Wit, T.; Ergun, R. E.; MacDowall, R. J.; Pulupa, M.; Andre, M.; Bolton, M.; Bougeret, J.-L.; Bowen, T. A.; Burgess, D.; Cattell, C. A.; Chandran, B. D. G.; Chaston, C. C.; Chen, C. H. K.; Choi, M. K.; Connerney, J. E.; Cranmer, S.; Diaz-Aguado, M.; Donakowski, W.; Drake, J. F.; Farrell, W. M.; Fergeau, P.; Fermin, J.; Fischer, J.; Fox, N.; Glaser, D.; Goldstein, M.; Gordon, D.; Hanson, E.; Harris, S. E.; Hayes, L. M.; Hinze, J. J.; Hollweg, J. V.; Horbury, T. S.; Howard, R. A.; Hoxie, V.; Jannet, G.; Karlsson, M.; Kasper, J. C.; Kellogg, P. J.; Kien, M.; Klimchuk, J. A.; Krasnoselskikh, V. V.; Krucker, S.; Lynch, J. J.; Maksimovic, M.; Malaspina, D. M.; Marker, S.; Martin, P.; Martinez-Oliveros, J.; McCauley, J.; McComas, D. J.; McDonald, T.; Meyer-Vernet, N.; Moncuquet, M.; Monson, S. J.; Mozer, F. S.; Murphy, S. D.; Odom, J.; Oliverson, R.; Olson, J.; Parker, E. N.; Pankow, D.; Phan, T.; Quataert, E.; Quinn, T.; Ruplin, S. W.; Salem, C.; Seitz, D.; Sheppard, D. A.; Siy, A.; Stevens, K.; Summers, D.; Szabo, A.; Timofeeva, M.; Vaivads, A.; Velli, M.; Yehle, A.; Werthimer, D.; Wygant, J. R.
2016-12-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
Noise evaluation of a point autofocus surface topography measuring instrument
NASA Astrophysics Data System (ADS)
Maculotti, Giacomo; Feng, Xiaobing; Galetto, Maurizio; Leach, Richard
2018-06-01
In this work, the measurement noise of a point autofocus surface topography measuring instrument is evaluated, as the first step towards establishing a route to traceability for this type of instrument. The evaluation is based on the determination of the metrological characteristics for noise as outlined in draft ISO specification standards by using a calibrated optical flat. The static noise and repeatability of the autofocus sensor are evaluated. The influence of environmental disturbances on the measured surface topography and the built-in software to compensate for such influences are also investigated. The instrument was found to have a measurement noise of approximately 2 nm or, when expressed with the measurement bandwidth, 0.4 nm for a single-point measurement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cadell, S. R.; Woods, B. G.
2012-07-01
To measure the changing gas composition of the coolant during a postulated High Temperature Gas Reactor (HTGR) accident, an instrument is needed. This instrument must be compact enough to measure the ratio of the coolant versus the break gas in an individual coolant channel. This instrument must minimally impact the fluid flow and provide for non-direct signal routing to allow minimal disturbance to adjacent channels. The instrument must have a flexible geometry to allow for the measurement of larger volumes such as in the upper or lower plenum of a HTGR. The instrument must be capable of accurately functioning throughmore » the full operating temperature and pressure of a HTGR. This instrument is not commercially available, but a literature survey has shown that building off of the present work on Capacitance Sensors and Cross-Capacitors will provide a basis for the development of the desired instrument. One difficulty in developing and instrument to operate at HTGR temperatures is acquiring an electrical conductor that will not melt at 1600 deg. C. This requirement limits the material selection to high temperature ceramics, graphite, and exotic metals. An additional concern for the instrument is properly accounting for the thermal expansion of both the sensing components and the gas being measured. This work covers the basic instrument overview with a thorough discussion of the associated uncertainty in making these measurements. (authors)« less
Berens, Angelique M; Harbison, Richard Alex; Li, Yangming; Bly, Randall A; Aghdasi, Nava; Ferreira, Manuel; Hannaford, Blake; Moe, Kris S
2017-08-01
To develop a method to measure intraoperative surgical instrument motion. This model will be applicable to the study of surgical instrument kinematics including surgical training, skill verification, and the development of surgical warning systems that detect aberrant instrument motion that may result in patient injury. We developed an algorithm to automate derivation of surgical instrument kinematics in an endoscopic endonasal skull base surgery model. Surgical instrument motion was recorded during a cadaveric endoscopic transnasal approach to the pituitary using a navigation system modified to record intraoperative time-stamped Euclidian coordinates and Euler angles. Microdebrider tip coordinates and angles were referenced to the cadaver's preoperative computed tomography scan allowing us to assess surgical instrument kinematics over time. A representative cadaveric endoscopic endonasal approach to the pituitary was performed to demonstrate feasibility of our algorithm for deriving surgical instrument kinematics. Technical feasibility of automatically measuring intraoperative surgical instrument motion and deriving kinematics measurements was demonstrated using standard navigation equipment.
NASA Technical Reports Server (NTRS)
Rincon, Rafael F.; Fatoyinbo, Temilola; Ranson, K. Jon; Osmanoglu, Batuhan; Sun, Guoqing; Deshpande, Manohar D.; Perrine, Martin L.; Du Toit, Cornelis F.; Bonds, Quenton; Beck, Jaclyn;
2014-01-01
EcoSAR is a new synthetic aperture radar (SAR) instrument being developed at the NASA/ Goddard Space Flight Center (GSFC) for the polarimetric and interferometric measurements of ecosystem structure and biomass. The instrument uses a phased-array beamforming architecture and supports full polarimetric measurements and single pass interferometry. This Instrument development is part of NASA's Earth Science Technology Office Instrument Incubator Program (ESTO IIP).
SAO Participation in the GOME and SCIAMACHY Satellite Instrument Programs
NASA Technical Reports Server (NTRS)
Hilsenrath, Ernest (Technical Monitor); Chance, Kelly; Kurosu, Thomas
2004-01-01
This report summarizes the progress on our three-year program of research to refine the measurement capability for satellite-based instruments that monitor ozone and other trace species in the Earth's stratosphere and troposphere, to retrieve global distributions of these and other constituents h m the GOME and SCIAMACHY satellite instruments, and to conduct scientific studies for the ILAS instruments. This continues our involvements as a U.S. participant in GOME and SCIAMACHY since their inception, and as a member of the ILAS-II Science Team. These programs have led to the launch of the first satellite instrument specifically designed to measure height-resolved ozone, including the tropospheric component (GOME), and the development of the first satellite instrument that will measure tropospheric ozone simultaneously with NO2, CO, HCHO, N2O, H2O, and CH4 (SCIAMACHY). The GOME program now includes the GOME-2 instruments, to be launched on the Eumetsat Metop satellites, providing long-term continuity in European measurements of global ozone that complement the measurements of the TOMS, SBUV, OMI, OMPS instruments. The research primarily focuses on two areas: Data analysis, including algorithm development and validation studies that will improve the quality of retrieved data products, in support for future field campaigns (to complement in situ and airborne campaigns with satellite measurements), and scientific analyses to be interfaced to atmospheric modeling studies.
SAO Participation in the GOME and SCIAMACHY Satellite Instrument Programs
NASA Technical Reports Server (NTRS)
Chance, Kelly; Kurosu, Thomas
2003-01-01
This report summarizes the progress on our three-year program of research to refine the measurement capability for satellite-based instruments that monitor ozone and other trace species in the Earth's stratosphere and troposphere, to retrieve global distributions of these and other constituents from the GOME and SCIAMACHY satellite instruments, and to conduct scientific studies for the ILAS instruments. This continues our involvements as a U.S. participant in GOME and SCIAMACHY since their inception, and as a member of the ILAS-II Science Team. These programs have led to the launch of the first satellite instrument specifically designed to measure height-resolved ozone, including the tropospheric component (GOME), and the development of the first satellite instrument that will measure tropospheric ozone simultaneously with NO2, CO, HCHO, N2O, H2O, and CH4 (SCIAMACHY). The GOME program now includes the GOME-2 instruments, to be launched on the Eumetsat Metop satellites, providing long-term continuity in European measurements of global ozone that complement the measurements of the TOMS, SBW, OMI, OMPS instruments. The research primarily focuses on two areas: Data analysis, including algorithm development and validation studies that will improve the quality of retrieved data products, in support for future field campaigns (to complement in situ and airborne campaigns with satellite measurements), and scientific analyses to be interfaced to atmospheric modeling studies.
Liu, Yan; Cai, Wensheng; Shao, Xueguang
2016-12-05
Calibration transfer is essential for practical applications of near infrared (NIR) spectroscopy because the measurements of the spectra may be performed on different instruments and the difference between the instruments must be corrected. For most of calibration transfer methods, standard samples are necessary to construct the transfer model using the spectra of the samples measured on two instruments, named as master and slave instrument, respectively. In this work, a method named as linear model correction (LMC) is proposed for calibration transfer without standard samples. The method is based on the fact that, for the samples with similar physical and chemical properties, the spectra measured on different instruments are linearly correlated. The fact makes the coefficients of the linear models constructed by the spectra measured on different instruments are similar in profile. Therefore, by using the constrained optimization method, the coefficients of the master model can be transferred into that of the slave model with a few spectra measured on slave instrument. Two NIR datasets of corn and plant leaf samples measured with different instruments are used to test the performance of the method. The results show that, for both the datasets, the spectra can be correctly predicted using the transferred partial least squares (PLS) models. Because standard samples are not necessary in the method, it may be more useful in practical uses. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluating nursing administration instruments.
Huber, D L; Maas, M; McCloskey, J; Scherb, C A; Goode, C J; Watson, C
2000-05-01
To identify and evaluate available measures that can be used to examine the effects of management innovations in five important areas: autonomy, conflict, job satisfaction, leadership, and organizational climate. Management interventions target the context in which care is delivered and through which evidence for practice diffuses. These innovations need to be evaluated for their effects on desired outcomes. However, busy nurses may not have the time to locate, evaluate, and select instruments to measure expected nursing administration outcomes without research-based guidance. Multiple and complex important contextual variables need psychometrically sound and easy-to-use measurement instruments identified for use in both practice and research. An expert focus group consensus methodology was used in this evaluation research to review available instruments in the five areas and evaluate which of these instruments are psychometrically sound and easy to use in the practice setting. The result is a portfolio of measures, clustered by concept and displayed on a spreadsheet. Retrieval information is provided. The portfolio includes the expert consensus judgment as well as useful descriptive information. The research reported here identifies psychometrically sound and easy-to-use instruments for measuring five key variables to be included in a portfolio. The results of this study can be used as a beginning for saving time in instrument selection and as an aid for determining the best instrument for measuring outcomes from a clinical or management intervention.
Instruments and Taxonomy of Workplace Bullying in Health Care Organizations.
Park, Eun-Jun; Lee, Mikyoung; Park, Myungsook
2017-12-01
This study was aimed to evaluate the methodological issues and comprehensiveness of workplace bullying instruments and to suggest a taxonomy of psychological abuse. Nineteen instruments applied in health care organizations and 469 questionnaire items mainly regarding psychological abuse were collected through a literature review. Three researchers classified the questionnaire items according to a "taxonomy of psychological abuse in the workplace." Many instruments of workplace bullying were developed in the 2000s using a reflective measurement model, but their psychometric property was not sufficient and the measurement model is questioned. Based on the questionnaire items, the "taxonomy of psychological abuse in the workplace" was modified by adding two new subcategories (unachievable work and unfair treatment) and clarifying some operational definitions. According to the modified taxonomy of 11 (sub)categories, the reviewed instruments assessed 6.5 (sub)categories on average. No instrument measured all (sub)categories. Category 4.2 (disrespect, humiliation, and rejection of the person) was measured in all instruments, followed by Categories 5 (professional discredit and denigration) and 1.2 (social isolation) behaviors. The current instruments are not comprehensive enough. It is suggested that the modified taxonomy is verified and guide more reliable and inclusive instruments in the future. Furthermore, a formative measurement model, which defines a bullying as an inventory of different types of behaviors, should be used. Copyright © 2017. Published by Elsevier B.V.
Hartmann, Christine W; Palmer, Jennifer A; Mills, Whitney L; Pimentel, Camilla B; Allen, Rebecca S; Wewiorski, Nancy J; Dillon, Kristen R; Snow, A Lynn
2017-08-01
Enhanced interpersonal relationships and meaningful resident engagement in daily life are central to nursing home cultural transformation, yet these critical components of person-centered care may be difficult for frontline staff to measure using traditional research instruments. To address the need for easy-to-use instruments to help nursing home staff members evaluate and improve person-centered care, the psychometric method of cognitive-based interviewing was used to adapt a structured observation instrument originally developed for researchers and nursing home surveyors. Twenty-eight staff members from 2 Veterans Health Administration (VHA) nursing homes participated in 1 of 3 rounds of cognitive-based interviews, using the instrument in real-life situations. Modifications to the original instrument were guided by a cognitive processing model of instrument refinement. Following 2 rounds of cognitive interviews, pretesting of the revised instrument, and another round of cognitive interviews, the resulting set of 3 short instruments mirrored the concepts of the original longer instrument but were significantly easier for frontline staff to understand and use. Final results indicated frontline staff found the revised instruments feasible to use and clinically relevant in measuring and improving the lived experience of a changing culture. This article provides a framework for developing or adapting other measurement tools for frontline culture change efforts in nursing homes, in addition to reporting on a practical set of instruments to measure aspects of person-centered care. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
USDA-ARS?s Scientific Manuscript database
Fiber properties measured by high volume instrument (HVI) and advanced fiber information system (AFIS) are currently being used in Upland cotton (Gossypium hirsutum L.) breeding. It would be interesting to know if selections for parameters measured by the two instrumental systems are equally effici...
Development of a Measurement Instrument to Assess Students' Electrolyte Conceptual Understanding
ERIC Educational Resources Information Center
Lu, Shanshan; Bi, Hualin
2016-01-01
To assess students' conceptual understanding levels and diagnose alternative frameworks of the electrolyte concept, a measurement instrument was developed using the Rasch model. This paper reports the use of the measurement instrument to assess 559 students from grade 10 to grade 12 in two cities. The results provided both diagnostic and summative…
75 FR 20570 - Information Collection; Submission for OMB Review, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-20
... instrument is to measure community impact of RSVP grantees. Comment 9. Three commenters suggested that there... of the instrument is to measure community impact of RSVP grantees and to clarify that the benefit of... purpose of the instrument is to measure community impact of RSVP grantees. Comment 18. One way to minimize...
How to Measure Elementary Teachers' Interest in Teaching Chemistry?
ERIC Educational Resources Information Center
Herranen, Jaana Kristiina; Vesterinen, Veli-Matti; Aksela, Maija Katariina
2015-01-01
The aim of this study was to create an instrument to measure elementary teachers' interest in teaching chemistry. The interest in chemistry teaching instrument (ICTI) was created to measure both the affective and cognitive components of interest. After establishing the face and content validity of the instrument, the internal consistency of the…
Corrêa, Marcelo de Paula; Godin-Beekmann, Sophie; Haeffelin, Martial; Brogniez, Colette; Verschaeve, Franck; Saiag, Philippe; Pazmiño, Andrea; Mahé, Emmanuel
2010-04-01
Ultraviolet radiation (UVR) exposure, skin cancer and other related diseases are not just subjects of scientific literature. Nowadays, these themes are also discussed on television, newspapers and magazines for the general public. Consequently, the interest in prevention of sun overexposure is increasing, as the knowledge of photoprotection methods and UVR levels. The ultraviolet index (UVI) is a well-known tool recommended by the World Health Organization to avoid harmful effects of UV sunlight. UVI forecasts are provided by many national meteorological services, but local UVI measurements can provide a more realistic and appropriate evaluation of UVR levels. Indeed, as scientific instruments are very expensive and difficult to manipulate, several manufacturers and retail shops offer cheap and simple non-scientific instruments for UVI measurements, sometimes included in objects of everyday life, such as watches, outfits and hand-held instruments. In this work, we compare measurements provided by several commercial non-scientific instruments with data provided by a Bentham spectrometer, a very accurate sensor used for UV measurements. Results show that only a few of the instruments analyzed provide trustworthy UVI measurements.
Measurements of Carbon Monoxide with the MOPITT Instrument 1999-2009
NASA Astrophysics Data System (ADS)
Drummond, J. R.; Gille, J. C.; Edwards, D. P.; Deeter, M. N.; Zou, J.; Nichitiu, F.
2009-12-01
The Measurements Of Pollution In The Troposphere (MOPITT) instrument on the Terra spacecraft is completing ten years of operation measuring carbon monoxide (CO) over the planet. These measurements have demonstrated the changes of CO in both space and time and shown a planet with very large variations in concentrations depending upon events and circumstances. This talk will review the MOPITT dataset and discuss how experience with the MOPITT instrument and with data processing have led to significant improvements in our understanding of the nature of the measurements and their strengths and limitations. These studies have led to improvements in our ability to understand the sensitivity of the measurements to boundary-layer CO (to cite a single example). This presentation leads naturally into a discussion of the future improvements of both of MOPITT instrument datasets and future instruments using similar techniques. MOPITT was provided to the Terra spacecraft by the Canadian Space Agency and was built by COMDEV of Cambridge, Ontario. Data processing is performed by the MOPITT team at the National Center for Atmospheric Research, Boulder, CO. Instrument control is by the team at the University of Toronto.
2014-01-01
Background Health impairments can result in disability and changed work productivity imposing considerable costs for the employee, employer and society as a whole. A large number of instruments exist to measure health-related productivity changes; however their methodological quality remains unclear. This systematic review critically appraised the measurement properties in generic self-reported instruments that measure health-related productivity changes to recommend appropriate instruments for use in occupational and economic health practice. Methods PubMed, PsycINFO, Econlit and Embase were systematically searched for studies whereof: (i) instruments measured health-related productivity changes; (ii) the aim was to evaluate instrument measurement properties; (iii) instruments were generic; (iv) ratings were self-reported; (v) full-texts were available. Next, methodological quality appraisal was based on COSMIN elements: (i) internal consistency; (ii) reliability; (iii) measurement error; (iv) content validity; (v) structural validity; (vi) hypotheses testing; (vii) cross-cultural validity; (viii) criterion validity; and (ix) responsiveness. Recommendations are based on evidence syntheses. Results This review included 25 articles assessing the reliability, validity and responsiveness of 15 different generic self-reported instruments measuring health-related productivity changes. Most studies evaluated criterion validity, none evaluated cross-cultural validity and information on measurement error is lacking. The Work Limitation Questionnaire (WLQ) was most frequently evaluated with moderate respectively strong positive evidence for content and structural validity and negative evidence for reliability, hypothesis testing and responsiveness. Less frequently evaluated, the Stanford Presenteeism Scale (SPS) showed strong positive evidence for internal consistency and structural validity, and moderate positive evidence for hypotheses testing and criterion validity. The Productivity and Disease Questionnaire (PRODISQ) yielded strong positive evidence for content validity, evidence for other properties is lacking. The other instruments resulted in mostly fair-to-poor quality ratings with limited evidence. Conclusions Decisions based on the content of the instrument, usage purpose, target country and population, and available evidence are recommended. Until high-quality studies are in place to accurately assess the measurement properties of the currently available instruments, the WLQ and, in a Dutch context, the PRODISQ are cautiously preferred based on its strong positive evidence for content validity. Based on its strong positive evidence for internal consistency and structural validity, the SPS is cautiously recommended. PMID:24495301
ERIC Educational Resources Information Center
Ahrens, Willis
As part of a social studies instruction improvement program, measurement instruments were developed to measure attitudes of and evaluate courses for teachers and students in grades 3-12. The measurement instruments presented are surveys used in the social studies program. The purposes of the improvement project are to use the multimedia approach…
NASA Astrophysics Data System (ADS)
Papadopoulos, K.
2014-12-01
XCOR Aerospace, a commercial space company, is planning to provide frequent, low cost access to near-Earth space on the Lynx suborbital Reusable Launch Vehicle (sRLV). Measurements in the external vacuum environment can be made and can launch from most runways on a limited lead time. Lynx can operate as a platform to perform suborbital in situ measurements and remote sensing to supplement models and simulations with new data points. These measurements can serve as a quantitative link to existing instruments and be used as a basis to calibrate detectors on spacecraft. Easier access to suborbital data can improve the longevity and cohesiveness of spacecraft and ground-based resources. A study of how these measurements can be made on Lynx sRLV will be presented. At the boundary between terrestrial and space weather, measurements from instruments on Lynx can help develop algorithms to optimize the consolidation of ground and satellite based data as well as assimilate global models with new data points. For example, current tides and the equatorial electrojet, essential to understanding the Thermosphere-Ionosphere system, can be measured in situ frequently and on short notice. Furthermore, a negative-ion spectrometer and a Faraday cup, can take measurements of the D-region ion composition. A differential GPS receiver can infer the spatial gradient of ionospheric electron density. Instruments and optics on spacecraft degrade over time, leading to calibration drift. Lynx can be a cost effective platform for deploying a reference instrument to calibrate satellites with a frequent and fast turnaround and a successful return of the instrument. A calibrated reference instrument on Lynx can make collocated observations as another instrument and corrections are made for the latter, thus ensuring data consistency and mission longevity. Aboard a sRLV, atmospheric conditions that distort remotely sensed data (ground and spacecraft based) can be measured in situ. Moreover, an active instrument can be deployed in a sRLV under a satellite track, and serve as a "standard candle" for instruments on satellites. Yearly calibrations of the Solar Extreme Ultraviolet Experiment (SEE) instrument aboard the TIMED orbiter using sounding rockets depict the necessity of calibrations and illustrates calibration frequency.
Bellido-Pérez, Mercedes; Monforte-Royo, Cristina; Tomás-Sábado, Joaquín; Porta-Sales, Josep; Balaguer, Albert
2017-06-01
Patients with advanced conditions may present a wish to hasten death. Assessing this wish is complex due to the nature of the phenomenon and the difficulty of conceptualising it. To identify and analyse existing instruments for assessing the wish to hasten death and to rate their reported psychometric properties. Systematic review based on PRISMA guidelines. The COnsensus-based Standards for the selection of health Measurement INstruments checklist was used to evaluate the methodological quality of validation studies and the measurement properties of the instrument described. The CINAHL, PsycINFO, Pubmed and Web of Science databases were searched from inception to November 2015. A total of 50 articles involving assessment of the wish to hasten death were included. Eight concerned instrument validation and were evaluated using COnsensus-based Standards for the selection of health Measurement INstruments criteria. They reported data for between two and seven measurement properties, with ratings between fair and excellent. Of the seven instruments identified, the Desire for Death Rating Scale or the Schedule of Attitudes toward Hastened Death feature in 48 of the 50 articles. The Schedule of Attitudes toward Hastened Death is the most widely used and is the instrument whose psychometric properties have been most often analysed. Versions of the Schedule of Attitudes toward Hastened Death are available in five languages other than the original English. This systematic review has analysed existing instruments for assessing the wish to hasten death. It has also explored the methodological quality of studies that have examined the measurement properties of these instruments and offers ratings of the reported properties. These results will be useful to clinicians and researchers with an interest in a phenomenon of considerable relevance to advanced patients.
A systematic review of instruments for measuring outcomes in economic evaluation within aged care.
Bulamu, Norma B; Kaambwa, Billingsley; Ratcliffe, Julie
2015-11-09
This paper describes the methods and results of a systematic review to identify instruments used to measure quality of life outcomes in older people. The primary focus of the review was to identify instruments suitable for application with older people within economic evaluations conducted in the aged care sector. Online databases searched were PubMed, Medline, Scopus, and Web of Science, PsycInfo, CINAHL, Embase and Informit. Studies that met the following criteria were included: 1) study population exclusively above 65 years of age 2) measured health status, health related quality of life or quality of life outcomes more broadly through use of an instrument developed for this purpose, 3) used a generic preference based instrument or an older person specific preference based or non-preference based instrument or both, and 4) published in journals in the English language after 2000. The most commonly applied generic preference based instrument in both the community and residential aged care context was the EuroQol - 5 Dimensions (EQ-5D), followed by the Adult Social Care Outcomes Toolkit (ASCOT) and the Health Utilities Index (HUI2/3). The most widely applied older person specific instrument was the ICEpop CAPability measure for Older people (ICECAP-O) in both community and residential aged care. In the absence of an ideal instrument for incorporating into economic evaluations in the aged care sector, this review recommends the use of a generic preference based measure of health related quality of life such as the EQ-5D to obtain quality adjusted life years, in combination with an instrument that has a broader quality of life focus like the ASCOT, which was designed specifically for evaluating interventions in social care or the ICECAP-O, a capability measure for older people.
Bellido-Pérez, Mercedes; Monforte-Royo, Cristina; Tomás-Sábado, Joaquín; Porta-Sales, Josep; Balaguer, Albert
2016-01-01
Background: Patients with advanced conditions may present a wish to hasten death. Assessing this wish is complex due to the nature of the phenomenon and the difficulty of conceptualising it. Aim: To identify and analyse existing instruments for assessing the wish to hasten death and to rate their reported psychometric properties. Design: Systematic review based on PRISMA guidelines. The COnsensus-based Standards for the selection of health Measurement INstruments checklist was used to evaluate the methodological quality of validation studies and the measurement properties of the instrument described. Data sources: The CINAHL, PsycINFO, Pubmed and Web of Science databases were searched from inception to November 2015. Results: A total of 50 articles involving assessment of the wish to hasten death were included. Eight concerned instrument validation and were evaluated using COnsensus-based Standards for the selection of health Measurement INstruments criteria. They reported data for between two and seven measurement properties, with ratings between fair and excellent. Of the seven instruments identified, the Desire for Death Rating Scale or the Schedule of Attitudes toward Hastened Death feature in 48 of the 50 articles. The Schedule of Attitudes toward Hastened Death is the most widely used and is the instrument whose psychometric properties have been most often analysed. Versions of the Schedule of Attitudes toward Hastened Death are available in five languages other than the original English. Conclusion: This systematic review has analysed existing instruments for assessing the wish to hasten death. It has also explored the methodological quality of studies that have examined the measurement properties of these instruments and offers ratings of the reported properties. These results will be useful to clinicians and researchers with an interest in a phenomenon of considerable relevance to advanced patients. PMID:28124578
Hernández-Garbanzo, Yenory; Brosh, Joanne; Serrano, Elena L; Cason, Katherine L; Bhattarai, Ranju
2013-01-01
To identify the psychometric properties of evaluation instruments that measure mediators of dietary behaviors in school-aged children. Systematic search of scientific databases limited to 1999-2010. Psychometric properties related to development and testing of self-report instruments for children 8-12 years old. Systematic search of 189 articles and review of 15 instruments (20 associated articles) meeting the inclusion criteria. Search terms used included children, school, nutrition, diet, nutrition education, and evaluation. Fourteen studies used a theoretical framework to guide the instrument's development. Knowledge and self-efficacy were the most commonly used psychosocial measures. Twelve instruments focused on specific nutrition-related behaviors. Eight instruments included over 40 items and used age-appropriate response formats. Acceptable reliability properties were most commonly reported for attitude and self-efficacy measures. Although most of the instruments were reviewed by experts (n = 8) and/or pilot-tested (n = 9), only 7 were tested using both rigorous types of validity and with low-income youth. Results from this review suggest that additional research is needed to develop more robust psychosocial measures for dietary behaviors, for low-income youth audiences. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
Merged Long-Term Data Sets from TOMS and SBUV Total Ozone Measurements
NASA Technical Reports Server (NTRS)
Stolarski, Richard; McPeters, Richard; Labow, Gordon J.; Hollandsworth, Stacey; Flynn, Larry; Einaudi, Franco (Technical Monitor)
2000-01-01
Total ozone has been measured by a series of nadir-viewing satellite instruments. These measurements begin with the Total Ozone Mapping Spectrometer (TOMS) and Solar Backscatter UltraViolet (SBUV) instruments on Nimbus 7, launched in late 1978. The measurements have continued with the Meteor 3 TOMS, Earth Probe TOMS, and NOAA 9,11,14 SBUV/2 instruments. The problem for producing a long-term data set is establishing the relative calibration of the various instruments to better than 1%. There was a nearly two year gap between the Meteor 3 TOMS and the Earth Probe TOMS. This gap is filled by the NOAA 9 and 11 SBUV/2 instruments, but they were in drifting orbits that result in effective gaps in the record when the equator crossing time occurs at large solar zenith angle. We have used recently re-derived calibrations of the SBUV instruments using the D-pair (306/313 nm wavelengths) data at the equator. These equatorial D-pair measurements should maintain the internal calibration of each instrument better than previous approaches. We then use the comparisons between instruments during their overlap periods to establish a consistent calibration over the entire data set. The resulting merged ozone data set is independent of the ground-based Dobson/Brewer network.
FMP study of pilot workload. Qualification of workload via instrument scan
NASA Technical Reports Server (NTRS)
Tolel, J. R.; Vivaudou, M.; Harris, R. L., Sr.; Ephrath, A.
1982-01-01
Various methods of measuring a pilot's mental workload are discussed. Scanning the various flight instruments with good scan pattern and other verbal tasks during instrument landings is given special attention for measuring pilot workload.
Sjoding, Michael W; Schoenfeld, David A; Brown, Samuel M; Hough, Catherine L; Yealy, Donald M; Moss, Marc; Angus, Derek C; Iwashyna, Theodore J
2017-01-01
After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT's power to measure significant differences in these outcomes is poorly understood. Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. We derived a general formula and Stata code for calculating an RCT's power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress-like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT ( www.clinicaltrials.gov identifier NCT02509078). On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Examining instruments' power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities.
NASA Technical Reports Server (NTRS)
Butler, J.J.; Johnson, B. C.; Rice, J. P.; Shirley, E. L.; Barnes, R.A.
2008-01-01
There is a 5 W/sq m (about 0.35 %) difference between current on-orbit Total Solar Irradiance (TSI) measurements. On 18-20 July 2005, a workshop was held at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland that focused on understanding possible reasons for this difference, through an examination of the instrument designs, calibration approaches, and appropriate measurement equations. The instruments studied in that workshop included the Active Cavity Radiometer Irradiance Monitor III (ACRIM III) on the Active Cavity Radiometer Irradiance Monitor SATellite (ACRIMSAT), the Total Irradiance Monitor (TIM) on the Solar Radiation and Climate Experiment (SORCE), the Variability of solar IRradiance and Gravity Oscillations (VIRGO) on the Solar and Heliospheric Observatory (SOHO), and the Earth Radiation Budget Experiment (ERBE) on the Earth Radiation Budget Satellite (ERBS). Presentations for each instrument included descriptions of its design, its measurement equation and uncertainty budget, and the methods used to assess on-orbit degradation. The workshop also included a session on satellite- and ground-based instrument comparisons and a session on laboratory-based comparisons and the application of new laboratory comparison techniques. The workshop has led to investigations of the effects of diffraction and of aperture area measurements on the differences between instruments. In addition, a laboratory-based instrument comparison is proposed that uses optical power measurements (with lasers that underEll the apertures of the TSI instruments), irradiance measurements (with lasers that overfill the apertures of the TSI instrument), and a cryogenic electrical substitution radiometer as a standard for comparing the instruments. A summary of the workshop and an overview of the proposed research efforts are presented here.
Butler, J. J; Johnson, B. C; Rice, J. P; Shirley, E. L; Barnes, R. A
2008-01-01
There is a 5 W/m2 (about 0.35 %) difference between current on-orbit Total Solar Irradiance (TSI) measurements. On 18–20 July 2005, a workshop was held at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland that focused on understanding possible reasons for this difference, through an examination of the instrument designs, calibration approaches, and appropriate measurement equations. The instruments studied in that workshop included the Active Cavity Radiometer Irradiance Monitor III (ACRIM III) on the Active Cavity Radiometer Irradiance Monitor SATellite (ACRIMSAT), the Total Irradiance Monitor (TIM) on the Solar Radiation and Climate Experiment (SORCE), the Variability of solar IRradiance and Gravity Oscillations (VIRGO) on the Solar and Heliospheric Observatory (SOHO), and the Earth Radiation Budget Experiment (ERBE) on the Earth Radiation Budget Satellite (ERBS). Presentations for each instrument included descriptions of its design, its measurement equation and uncertainty budget, and the methods used to assess on-orbit degradation. The workshop also included a session on satellite- and ground-based instrument comparisons and a session on laboratory-based comparisons and the application of new laboratory comparison techniques. The workshop has led to investigations of the effects of diffraction and of aperture area measurements on the differences between instruments. In addition, a laboratory-based instrument comparison is proposed that uses optical power measurements (with lasers that underfill the apertures of the TSI instruments), irradiance measurements (with lasers that overfill the apertures of the TSI instrument), and a cryogenic electrical substitution radiometer as a standard for comparing the instruments. A summary of the workshop and an overview of the proposed research efforts are presented here. PMID:27096120
Field and laboratory comparison of PM10 instruments in high winds
NASA Astrophysics Data System (ADS)
Sharratt, Brenton; Pi, Huawei
2018-06-01
Instruments capable of measuring PM10 (particulate matter ≤10 μm in aerodynamic diameter) concentrations may vary in performance as a result of different technologies utilized in measuring PM10. Therefore, the performance of five instruments capable of measuring PM10 concentrations above eroding soil surfaces was tested during high wind events at field sites in the Columbia Plateau and inside a wind tunnel. Comparisons among the Big Spring Number Eight (BSNE) sampler, DustTrak monitor, E-sampler, High-Volume sampler, and Tapered Element Oscillating Microbalance (TEOM) monitor were made at field sites during nine wind erosion events and inside a wind tunnel at two wind speeds (7 and 12 m s-1) and two ambient PM10 concentrations (2 and 50 mg m-3). PM10 concentrations were similar for the High-Volume sampler and TEOM monitor as well as for the BSNE samplers and DustTrak monitors but higher for the High-Volume sampler and TEOM monitor than the E-sampler during field erosion events. Based upon wind tunnel experiments, the TEOM monitor measured the highest PM10 concentration while the DustTrak monitor typically measured the lowest PM10 concentration as compared with other instruments. In addition, PM10 concentration appeared to lower for all instruments at a wind speed of 12 as compared with 7 m s-1 inside the wind tunnel. Differences in the performance of instruments in measuring PM10 concentration poses risks in comparing PM10 concentration among different instrument types or using multiple instrument types to jointly measure concentrations in the field or laboratory or even the same instrument type subject to different wind speeds.
[Shoulder disability questionnaires: a systematic review].
Fayad, F; Mace, Y; Lefevre-Colau, M M
2005-07-01
To identify all available shoulder disability questionnaires designed to measure physical functioning and to examine those with satisfactory clinimetric quality. We used the Medline database and the "Guide des outils de mesure de l'évaluation en médecine physique et de réadaptation" textbook to search for questionnaires. Analysis took into account the development methodology, clinimetric quality of the instruments and frequency of their utilization. We classified the instruments according to the International Classification of Functioning, Disability and Health. Thirty-eight instruments have been developed to measure disease-, shoulder- or upper extremity-specific outcome. Four scales assess upper-extremity disability and 3 others shoulder disability. We found 6 scales evaluating disability and shoulder pain, 7 scales measuring the quality of life in patients with various conditions of the shoulder, 14 scales combining objective and subjective measures, 2 pain scales and 2 unclassified scales. Older instruments developed before the advent of modern measurement development methodology usually combine objective and subjective measures. Recent instruments were designed with appropriate methodology. Most are self-administered questionnaires. Numerous shoulder outcome measure instruments are available. There is no "gold standard" for assessing shoulder function outcome in the general population.
Spuls, P I; Gerbens, L A A; Simpson, E; Apfelbacher, C J; Chalmers, J R; Thomas, K S; Prinsen, C A C; von Kobyletzki, L B; Singh, J A; Williams, H C; Schmitt, J
2017-04-01
The Harmonising Outcome Measures for Eczema (HOME) initiative has defined four core outcome domains for a core outcome set (COS) to be measured in all atopic eczema (AE) trials to ensure cross-trial comparison: clinical signs, symptoms, quality of life and long-term control. The aim of this paper is to report on the consensus process that was used to select the core instrument to consistently assess symptoms in all future AE trials. Following the HOME roadmap, two systematic reviews were performed which identified three instruments that had sufficient evidence of validity, reliability and feasibility to be considered for the final COS. At the fourth international HOME meeting, there was broad consensus among all stakeholders that the Patient-Oriented Eczema Measure (POEM) should be used as the core instrument (87·5% agreed, 9·4% unsure, 3·1% disagreed). All relevant stakeholders are encouraged to use POEM as the chosen instrument to measure the core domain of symptoms in all future AE clinical trials. Other instruments of interest can be used in addition to POEM. © 2016 British Association of Dermatologists.
NIST display colorimeter calibration facility
NASA Astrophysics Data System (ADS)
Brown, Steven W.; Ohno, Yoshihiro
2003-07-01
A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.
NASA Astrophysics Data System (ADS)
Ivanov, Yu. A.
2007-12-01
An analytical review is given of Russian and foreign measurement instruments employed in a system for automatically monitoring the water chemistry of the reactor coolant circuit and used in the development of projects of nuclear power stations equipped with VVER-1000 reactors and the nuclear station project AES 2006. The results of experience gained from the use of such measurement instruments at nuclear power stations operating in Russia and abroad are presented.
Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays
NASA Technical Reports Server (NTRS)
Noel, G. T.; Sliemers, F. A.; Deringer, G. C.; Wood, V. E.; Wilkes, K. E.; Gaines, G. B.; Carmichael, D. C.
1978-01-01
Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories - chemical, electrical, optical, thermal, mechanical, and other physicals. Using specified evaluation criteria, the most promising techniques and instruments for use in life prediction tests of arrays were selected.
Traceability of radiation protection instruments
NASA Astrophysics Data System (ADS)
Hino, Y.; Kurosawa, T.
2007-08-01
Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.
NASA Technical Reports Server (NTRS)
Beij, K Hilding
1933-01-01
This report presents a concise survey of the measurement of air speed and ground speed on board aircraft. Special attention is paid to the pitot-static air-speed meter which is the standard in the United States for airplanes. Air-speed meters of the rotating vane type are also discussed in considerable detail on account of their value as flight test instruments and as service instruments for airships. Methods of ground-speed measurement are treated briefly, with reference to the more important instruments. A bibliography on air-speed measurement concludes the report.
NASA Technical Reports Server (NTRS)
Goodkind, J. M.
1982-01-01
The superconducting gravimeter was developed and applied to field measurements. The stability of the instrument yielded the highest precision measurements of the Earth tides ever attained. It revealed unprecedented details about the effect of the atmosphere on gravity. Secular variations in gravity and the stability of the instruments were measured by comparing records from co-located instruments. These efforts have resulted in substantial reductions in the noise level at very low frequencies so that the peak differences between two instruments at the same location can be reduced to 0.1 micron gal.
Cadorin, Lucia; Bagnasco, Annamaria; Tolotti, Angela; Pagnucci, Nicola; Sasso, Loredana
2016-09-01
To identify, evaluate and describe the psychometric properties of instruments that measure learning outcomes in healthcare students. Meaningful learning is an active process that enables a wider and deeper understanding of concepts. It is the result of an interaction between new and prior knowledge and produces a long-standing change in knowledge and skills. In the field of education, validated and reliable instruments for assessing meaningful learning are needed. A psychometric systematic review. MEDLINE CINAHL, SCOPUS, ERIC, Cochrane Library, Psychology & Behavioural Sciences Collection Database from 1990-December 2013. Using pre-determined inclusion criteria, three reviewers independently identified studies for full-text review. Then they extracted data for quality appraisal and graded instrument validity using the Consensus-based Standards for the selection of the health status Measurement INstruments checklist and the Psychometric Grading Framework. Of the 57 studies identified for full-text review, 16 met the inclusion criteria and 13 different instruments were assessed. Following quality assessment, only one instrument was considered of good quality but it measured meaningful learning only in part; the others were either fair or poor. The Psychometric Grading Framework indicated that one instrument was weak, while the others were very weak. No instrument displayed adequate validity. The systematic review produced a synthesis of the psychometric properties of tools that measure learning outcomes in students of healthcare disciplines. Measuring learning outcomes is very important when educating health professionals. The identified tools may constitute a starting point for the development of other assessment tools. © 2016 John Wiley & Sons Ltd.
Du, Lei; Sun, Qiao; Cai, Changqing; Bai, Jie; Fan, Zhe; Zhang, Yue
2018-01-01
Traffic speed meters are important legal measuring instruments specially used for traffic speed enforcement and must be tested and verified in the field every year using a vehicular mobile standard speed-measuring instrument to ensure speed-measuring performances. The non-contact optical speed sensor and the GPS speed sensor are the two most common types of standard speed-measuring instruments. The non-contact optical speed sensor requires extremely high installation accuracy, and its speed-measuring error is nonlinear and uncorrectable. The speed-measuring accuracy of the GPS speed sensor is rapidly reduced if the amount of received satellites is insufficient enough, which often occurs in urban high-rise regions, tunnels, and mountainous regions. In this paper, a new standard speed-measuring instrument using a dual-antenna Doppler radar sensor is proposed based on a tradeoff between the installation accuracy requirement and the usage region limitation, which has no specified requirements for its mounting distance and no limitation on usage regions and can automatically compensate for the effect of an inclined installation angle on its speed-measuring accuracy. Theoretical model analysis, simulated speed measurement results, and field experimental results compared with a GPS speed sensor with high accuracy showed that the dual-antenna Doppler radar sensor is effective and reliable as a new standard speed-measuring instrument. PMID:29621142
Du, Lei; Sun, Qiao; Cai, Changqing; Bai, Jie; Fan, Zhe; Zhang, Yue
2018-04-05
Traffic speed meters are important legal measuring instruments specially used for traffic speed enforcement and must be tested and verified in the field every year using a vehicular mobile standard speed-measuring instrument to ensure speed-measuring performances. The non-contact optical speed sensor and the GPS speed sensor are the two most common types of standard speed-measuring instruments. The non-contact optical speed sensor requires extremely high installation accuracy, and its speed-measuring error is nonlinear and uncorrectable. The speed-measuring accuracy of the GPS speed sensor is rapidly reduced if the amount of received satellites is insufficient enough, which often occurs in urban high-rise regions, tunnels, and mountainous regions. In this paper, a new standard speed-measuring instrument using a dual-antenna Doppler radar sensor is proposed based on a tradeoff between the installation accuracy requirement and the usage region limitation, which has no specified requirements for its mounting distance and no limitation on usage regions and can automatically compensate for the effect of an inclined installation angle on its speed-measuring accuracy. Theoretical model analysis, simulated speed measurement results, and field experimental results compared with a GPS speed sensor with high accuracy showed that the dual-antenna Doppler radar sensor is effective and reliable as a new standard speed-measuring instrument.
NASA Technical Reports Server (NTRS)
Heath, Donald F.; Ahmad, Zia
2001-01-01
In the early 1990s a series of surface-based direct sun and zenith sky measurements of total column ozone were made with SBUV/2 flight models and the SSBUV Space Shuttle instrument in Boulder, Colorado which were compared with NOAA Dobson Instrument direct sun observations and TOMS instrument overpass observations of column ozone. These early measurements led to the investigation of the accuracy of derived total column ozone amounts and aerosol optical depths from zenith sky observations. Following the development and availability of radiometrically stable IAD narrow band interference filter and nitrided silicon photodiodes a simple compact multifilter spectroradiometer was developed which can be used as a calibration transfer standard spectroradiometer (CTSS) or as a surface based instrument remote sensing instruments for measurements of total column ozone and aerosol optical depths. The total column ozone derived from zenith sky observations agrees with Dobson direct sun AD double wavelength pair measurements and with TOMS overpass ozone amounts within uncertainties of about 1%. When used as a calibration transfer standard spectroradiometer the multifilter spectroradiometer appears to be capable of establishing instrument radiometric calibration uncertainties of the order of 1% or less relative to national standards laboratory radiometric standards.
A systematic review of instruments that measure attitudes toward homosexual men.
Grey, Jeremy A; Robinson, Beatrice Bean E; Coleman, Eli; Bockting, Walter O
2013-01-01
Scientific interest in the measurement of homophobia and internalized homophobia has grown over the past 30 years, and new instruments and terms have emerged. To help researchers with the challenging task of identifying appropriate measures for studies in sexual-minority health, we reviewed measures of homophobia published in the academic literature from 1970 to 2012. Instruments that measured attitudes toward male homosexuals/homosexuality or measured homosexuals' internalized attitudes toward homosexuality were identified using measurement manuals and a systematic review. A total of 23 instruments met criteria for inclusion, and their features were summarized and compared. All 23 instruments met minimal criteria for adequate scale construction, including scale development, sampling, reliability, and evidence of validity. Validity evidence was diverse and was categorized as interaction with gay men, HIV/AIDS variables, mental health, and conservative religious or political beliefs. Homophobia was additionally correlated with authoritarianism and bias, gender ideology, gender differences, and reactions to homosexual stimuli. Internalized homophobia was validated by examining relationships with disclosing one's homosexuality and level of homosexual identity development. We hope this review will make the process of instrument selection more efficient by allowing researchers to easily locate, evaluate, and choose the proper measure based on their research question and population of interest.
ERIC Educational Resources Information Center
Villafañe, Sachel M.; Heyen, Bruce J.; Lewis, Jennifer E.; Loertscher, Jennifer; Minderhout, Vicky; Murray, Tracey Arnold
2016-01-01
Assessment instruments designed to measure student conceptual understanding and skills proficiency related to biochemistry are important to transform undergraduate biochemistry education. The purpose of this study was to develop an assessment instrument to measure student understanding of protein structure and enzyme inhibition in a new context,…
ERIC Educational Resources Information Center
Daigneault, Pierre-Marc; Jacob, Steve
2014-01-01
Although combining methods is nothing new, more contributions about why and how to mix methods for validation purposes are needed. This article presents a case of validating the inferences drawn from the Participatory Evaluation Measurement Instrument, an instrument that purports to measure stakeholder participation in evaluation. Although the…
Measurement of organizational culture and climate in healthcare.
Gershon, Robyn R M; Stone, Patricia W; Bakken, Suzanne; Larson, Elaine
2004-01-01
Although there is increasing interest in the relationship between organizational constructs and health services outcomes, information on the reliability and validity of the instruments measuring these constructs is sparse. Twelve instruments were identified that may have applicability in measuring organizational constructs in the healthcare setting. The authors describe and characterize these instruments and discuss the implications for nurse administrators.
ERIC Educational Resources Information Center
Barbu, Otilia C.; Marx, Ronald W.; Yaden, David B., Jr.; Levine-Donnerstein, Deborah
2016-01-01
This study examined a 13-item instrument measuring approaches to learning (AtL) as a component of school readiness in the context of early childhood socio-emotional development. Few instruments, limited to preschool teacher ratings, measure AtL among kindergarteners with short easy-to-use questionnaires. We investigated psychometric properties of…
An Instrument to Measure the Cognitive Ability Evaluation of the Taxonomy.
ERIC Educational Resources Information Center
Schaff, John F.
Described is the development of an instrument designed to measure the cognitive ability of evaluation in high school chemistry students. The instrument was composed of several situations found in chemistry courses, each designed to measure a student's evaluation ability based on his knowledge of kinetic-molecular theory as it applied to gases,…
Gagnon, Marie-Pierre; Attieh, Randa; Ghandour, El Kebir; Légaré, France; Ouimet, Mathieu; Estabrooks, Carole A; Grimshaw, Jeremy
2014-01-01
The translation of research into practices has been incomplete. Organizational readiness for change (ORC) is a potential facilitator of effective knowledge translation (KT). However we know little about the best way to assess ORC. Therefore, we sought to systematically review ORC measurement instruments. We searched for published studies in bibliographic databases (Pubmed, Embase, CINAHL, PsychINFO, Web of Science, etc.) up to November 1st, 2012. We included publications that developed ORC measures and/or empirically assessed ORC using an instrument at the organizational level in the health care context. We excluded articles if they did not refer specifically to ORC, did not concern the health care domain or were limited to individual-level change readiness. We focused on identifying the psychometric properties of instruments that were developed to assess readiness in an organization prior to implementing KT interventions in health care. We used the Standards for Educational and Psychological Testing to assess the psychometric properties of identified ORC measurement instruments. We found 26 eligible instruments described in 39 publications. According to the Standards for Educational and Psychological Testing, 18 (69%) of a total of 26 measurement instruments presented both validity and reliability criteria. The Texas Christian University -ORC (TCU-ORC) scale reported the highest instrument validity with a score of 4 out of 4. Only one instrument, namely the Modified Texas Christian University - Director version (TCU-ORC-D), reported a reliability score of 2 out of 3. No information was provided regarding the reliability and validity of five (19%) instruments. Our findings indicate that there are few valid and reliable ORC measurement instruments that could be applied to KT in the health care sector. The TCU-ORC instrument presents the best evidence in terms of validity testing. Future studies using this instrument could provide more knowledge on its relevance to diverse clinical contexts.
Gagnon, Marie-Pierre; Attieh, Randa; Ghandour, El Kebir; Légaré, France; Ouimet, Mathieu; Estabrooks, Carole A.; Grimshaw, Jeremy
2014-01-01
Background The translation of research into practices has been incomplete. Organizational readiness for change (ORC) is a potential facilitator of effective knowledge translation (KT). However we know little about the best way to assess ORC. Therefore, we sought to systematically review ORC measurement instruments. Methods We searched for published studies in bibliographic databases (Pubmed, Embase, CINAHL, PsychINFO, Web of Science, etc.) up to November 1st, 2012. We included publications that developed ORC measures and/or empirically assessed ORC using an instrument at the organizational level in the health care context. We excluded articles if they did not refer specifically to ORC, did not concern the health care domain or were limited to individual-level change readiness. We focused on identifying the psychometric properties of instruments that were developed to assess readiness in an organization prior to implementing KT interventions in health care. We used the Standards for Educational and Psychological Testing to assess the psychometric properties of identified ORC measurement instruments. Findings We found 26 eligible instruments described in 39 publications. According to the Standards for Educational and Psychological Testing, 18 (69%) of a total of 26 measurement instruments presented both validity and reliability criteria. The Texas Christian University –ORC (TCU-ORC) scale reported the highest instrument validity with a score of 4 out of 4. Only one instrument, namely the Modified Texas Christian University – Director version (TCU-ORC-D), reported a reliability score of 2 out of 3. No information was provided regarding the reliability and validity of five (19%) instruments. Conclusion Our findings indicate that there are few valid and reliable ORC measurement instruments that could be applied to KT in the health care sector. The TCU-ORC instrument presents the best evidence in terms of validity testing. Future studies using this instrument could provide more knowledge on its relevance to diverse clinical contexts. PMID:25474622
Casas, Francisco J; Ortiz, David; Villa, Enrique; Cano, Juan L; Cagigas, Jaime; Pérez, Ana R; Aja, Beatriz; Terán, J Vicente; de la Fuente, Luisa; Artal, Eduardo; Hoyland, Roger; Génova-Santos, Ricardo
2015-08-05
This paper presents preliminary polarization measurements and systematic-error characterization of the Thirty Gigahertz Instrument receiver developed for the QUIJOTE experiment. The instrument has been designed to measure the polarization of Cosmic Microwave Background radiation from the sky, obtaining the Q, U, and I Stokes parameters of the incoming signal simultaneously. Two kinds of linearly polarized input signals have been used as excitations in the polarimeter measurement tests in the laboratory; these show consistent results in terms of the Stokes parameters obtained. A measurement-based systematic-error characterization technique has been used in order to determine the possible sources of instrumental errors and to assist in the polarimeter calibration process.
El Hadri, Hind; Petersen, Elijah J.; Winchester, Michael R.
2016-01-01
The effect of ICP-MS instrument sensitivity drift on the accuracy of NP size measurements using single particle (sp)ICP-MS is investigated. Theoretical modeling and experimental measurements of the impact of instrument sensitivity drift are in agreement and indicate that drift can impact the measured size of spherical NPs by up to 25 %. Given this substantial bias in the measured size, a method was developed using an internal standard to correct for the impact of drift and was shown to accurately correct for a decrease in instrument sensitivity of up to 50 % for 30 nm and 60 nm gold nanoparticles. PMID:26894759
Instrument Drift Uncertainties and the Long-Term TOMS/SBUV Total Ozone Record
NASA Technical Reports Server (NTRS)
Solarski, Richard S.; Frith, Stacey
2005-01-01
Long-term climate records from satellites are often constructed from the measurements of a sequence of instruments launched at different times. Each of these instruments is calibrated prior to launch. After launch they are subjected to potential offsets and slow drifts in calibration. We illustrate these issues in the construction of a merged total ozone record from two TOMS and three SBUV instruments. This record extends from late 1978 through the present. The question is "How good are these records?". We have examined the uncertainty in determining the relative calibration of two instruments during an overlap period in their measurements. When comparing a TOMS instrument, such as that on Nimbus 7, with an SBUV instrument, also on Nimbus 7, we find systematic differences and random differences. We have combined these findings with estimates of individual instrument drift into a monte- carlo uncertainty propagation model. We estimate an instrument drift uncertainty of a little larger than 1 percent per decade over the 25-year history of the TOMS/SBUV measurements. We make an independent estimate of the drift uncertainty in the ground-based network of total ozone measurements and find it to be of similar, but slightly smaller magnitude. The implications of these uncertainties for trend and recovery determination will be discussed.
Averina, Maria; Jakobsen, Raymond
2017-05-01
Background Measurements of ionized calcium (Ca 2+ ) at concentrations less than 0.3 mmol/L are required for postfilter control in patients who receive extracorporeal circulation with sodium citrate anticoagulation. This study evaluates the stability of the Ca 2+ measurements at such concentrations. Methods The stability of the Ca 2+ measurements was tested by measuring daily the external standard Qualicheck concentration 3 s7950, Radiometer (0.22-0.25 mmol/L) by blood gas instruments ABL800 and ABL90, Radiometer. Two different Ca 2+ membrane lots were tested for the usual membrane lifetime of 12 weeks at ABL800 instruments. For the ABL90 instrument, the sensor cassette (with Ca 2+ membrane and electrode) was replaced after four weeks as required. Results We observed over 40% Ca 2+ increase within the usual 12 weeks lifetime of the Ca 2+ membrane at the ABL800 instruments. Measurements of Ca 2+ at concentrations less than 0.3 mmol/L were within acceptable limits for both ABL800 and ABL90 instruments when Ca 2+ membrane and sensor cassette were replaced after four weeks. Conclusions For ABL800 instruments, it is necessary to use an extra quality control (<0.3 mmol/L) in addition to the usual quality controls to monitor Ca 2+ measurements below 0.3 mmol/L. The acceptable stability of the Ca 2+ measurements can be achieved by the Ca 2+ membrane and sensor cassette replacement after four weeks. If the usual 12 weeks of Ca 2+ membrane lifetime is maintained, it may result in a clinically significant overestimation of Ca 2+ by ABL800 instruments.
Schoenfeld, David A.; Brown, Samuel M.; Hough, Catherine L.; Yealy, Donald M.; Moss, Marc; Angus, Derek C.; Iwashyna, Theodore J.
2017-01-01
Rationale: After the sample size of a randomized clinical trial (RCT) is set by the power requirement of its primary endpoint, investigators select secondary endpoints while unable to further adjust sample size. How the sensitivity and specificity of an instrument used to measure these outcomes, together with their expected underlying event rates, affect an RCT’s power to measure significant differences in these outcomes is poorly understood. Objectives: Motivated by the design of an RCT of neuromuscular blockade in acute respiratory distress syndrome, we examined how power to detect a difference in secondary endpoints varies with the sensitivity and specificity of the instrument used to measure such outcomes. Methods: We derived a general formula and Stata code for calculating an RCT’s power to detect differences in binary outcomes when such outcomes are measured with imperfect sensitivity and specificity. The formula informed the choice of instrument for measuring post-traumatic stress–like symptoms in the Reevaluation of Systemic Early Neuromuscular Blockade RCT (www.clinicaltrials.gov identifier NCT02509078). Measurements and Main Results: On the basis of published sensitivities and specificities, the Impact of Events Scale-Revised was predicted to measure a 36% symptom rate, whereas the Post-Traumatic Stress Symptoms instrument was predicted to measure a 23% rate, if the true underlying rate of post-traumatic stress symptoms were 25%. Despite its lower sensitivity, the briefer Post-Traumatic Stress Symptoms instrument provided superior power to detect a difference in rates between trial arms, owing to its higher specificity. Conclusions: Examining instruments’ power to detect differences in outcomes may guide their selection when multiple instruments exist, each with different sensitivities and specificities. PMID:27788018
Underwater Concrete Inspection Equipment
1991-04-01
nondestructive testing of con- crete waterfront structures. One instrument is a magnetic rebar locator that locates rebar in concrete structures and measures the...amount of con- crete cover over the rebar . Another instrument is a rebound hammer that measures the surface hardness of the concrete . The third...development of three specialized instruments for the underwater nondestructive testing or concrete waterfront structures. One instrument is a magnetic rebar
[The development of an oral biomechanical testing instrument].
Zhang, X H; Sun, X D; Lin, Z
2000-03-01
An oral biomechanical testing instrument, which is portable, powered with batteries and controlled by single chip microcomputer, was described. The instrument was characterized by its multichannel, high accuracy, low power dissipation, wide rage of force measurement and stable performance. It can be used for acquisiting, displaying and storing data. And it may be expected to be an ideal instrument for oral biomechanical measurements.
Skeletal and body composition evaluation
NASA Technical Reports Server (NTRS)
Mazess, R. B.
1983-01-01
Research on radiation detectors for absorptiometry; analysis of errors affective single photon absorptiometry and development of instrumentation; analysis of errors affecting dual photon absorptiometry and development of instrumentation; comparison of skeletal measurements with other techniques; cooperation with NASA projects for skeletal evaluation in spaceflight (Experiment MO-78) and in laboratory studies with immobilized animals; studies of postmenopausal osteoporosis; organization of scientific meetings and workshops on absorptiometric measurement; and development of instrumentation for measurement of fluid shifts in the human body were performed. Instrumentation was developed that allows accurate and precise (2% error) measurements of mineral content in compact and trabecular bone and of the total skeleton. Instrumentation was also developed to measure fluid shifts in the extremities. Radiation exposure with those procedures is low (2-10 MREM). One hundred seventy three technical reports and one hundred and four published papers of studies from the University of Wisconsin Bone Mineral Lab are listed.
Wind-instrument reflection function measurements in the time domain.
Keefe, D H
1996-04-01
Theoretical and computational analyses of wind-instrument sound production in the time domain have emerged as useful tools for understanding musical instrument acoustics, yet there exist few experimental measurements of the air-column response directly in the time domain. A new experimental, time-domain technique is proposed to measure the reflection function response of woodwind and brass-instrument air columns. This response is defined at the location of sound regeneration in the mouthpiece or double reed. A probe assembly comprised of an acoustic source and microphone is inserted directly into the air column entryway using a foam plug to ensure a leak-free fit. An initial calibration phase involves measurements on a single cylindrical tube of known dimensions. Measurements are presented on an alto saxophone and euphonium. The technique has promise for testing any musical instrument air columns using a single probe assembly and foam plugs over a range of diameters typical of air-column entryways.
Microcomputer control soft tube measuring-testing instrument
NASA Astrophysics Data System (ADS)
Zhou, Yanzhou; Jiang, Xiu-Zhen; Wang, Wen-Yi
1993-09-01
Soft tube are key and easily spoiled parts used by the vehicles in the transportation with large numbers. Measuring and testing of the tubes were made by hands for a long time. Cooperating with Harbin Railway Bureau recently we have developed a new kind of automatical measuring and testing instrument In the paper the instrument structure property and measuring principle are presented in details. Centre of the system is a singlechip processor INTEL 80C31 . It can collect deal with data and display the results on LED. Furthermore it brings electromagnetic valves and motors under control. Five soft tubes are measured and tested in the same time all the process is finished automatically. On the hardware and software counter-electromagnetic disturbance methods is adopted efficiently so the performance of the instrument is improved significantly. In the long run the instrument is reliable and practical It solves a quite difficult problem in the railway transportation.
Ares I Scale Model Acoustic Tests Instrumentation for Acoustic and Pressure Measurements
NASA Technical Reports Server (NTRS)
Vargas, Magda B.; Counter, Douglas D.
2011-01-01
The Ares I Scale Model Acoustic Test (ASMAT) was a development test performed at the Marshall Space Flight Center (MSFC) East Test Area (ETA) Test Stand 116. The test article included a 5% scale Ares I vehicle model and tower mounted on the Mobile Launcher. Acoustic and pressure data were measured by approximately 200 instruments located throughout the test article. There were four primary ASMAT instrument suites: ignition overpressure (IOP), lift-off acoustics (LOA), ground acoustics (GA), and spatial correlation (SC). Each instrumentation suite incorporated different sensor models which were selected based upon measurement requirements. These requirements included the type of measurement, exposure to the environment, instrumentation check-outs and data acquisition. The sensors were attached to the test article using different mounts and brackets dependent upon the location of the sensor. This presentation addresses the observed effect of the sensors and mounts on the acoustic and pressure measurements.
Reeds, Dominic N.; van Bakergem, Margaret A.; Marx, Christine M.; Brownson, Ross C.; Pamulapati, Surya C.; Hoehner, Christine M.
2015-01-01
Introduction Obesity prevention strategies are needed that target multiple settings, including the worksite. The objective of this study was to assess the state of science concerning available measures of worksite environmental and policy supports for physical activity (PA) and healthy eating (HE). Methods We searched multiple databases for instruments used to assess worksite environments and policies. Two commonly cited instruments developed by state public health departments were also included. Studies that were published from 1991 through 2013 in peer-reviewed publications and gray literature that discussed the development or use of these instruments were analyzed. Instrument administration mode and measurement properties were documented. Items were classified by general health topic, 5 domains of general worksite strategy, and 19 subdomains of worksite strategy specific to PA or HE. Characteristics of worksite measures were described including measurement properties, length, and administration mode, as well as frequencies of items by domain and subdomain. Results Seventeen instruments met inclusion criteria (9 employee surveys, 5 manager surveys, 1 observational assessment, and 2 studies that used multiple administration modes). Fourteen instruments included reliability testing. More items were related to PA than HE. Most instruments (n = 10) lacked items in the internal social environment domain. The most common PA subdomains were exercise facilities and lockers/showers; the most common HE subdomain was healthy options/vending. Conclusion This review highlights gaps in measurement of the worksite social environment. The findings provide a useful resource for researchers and practitioners and should inform future instrument development. PMID:25950572
Hipp, J Aaron; Reeds, Dominic N; van Bakergem, Margaret A; Marx, Christine M; Brownson, Ross C; Pamulapati, Surya C; Hoehner, Christine M
2015-05-07
Obesity prevention strategies are needed that target multiple settings, including the worksite. The objective of this study was to assess the state of science concerning available measures of worksite environmental and policy supports for physical activity (PA) and healthy eating (HE). We searched multiple databases for instruments used to assess worksite environments and policies. Two commonly cited instruments developed by state public health departments were also included. Studies that were published from 1991 through 2013 in peer-reviewed publications and gray literature that discussed the development or use of these instruments were analyzed. Instrument administration mode and measurement properties were documented. Items were classified by general health topic, 5 domains of general worksite strategy, and 19 subdomains of worksite strategy specific to PA or HE. Characteristics of worksite measures were described including measurement properties, length, and administration mode, as well as frequencies of items by domain and subdomain. Seventeen instruments met inclusion criteria (9 employee surveys, 5 manager surveys, 1 observational assessment, and 2 studies that used multiple administration modes). Fourteen instruments included reliability testing. More items were related to PA than HE. Most instruments (n = 10) lacked items in the internal social environment domain. The most common PA subdomains were exercise facilities and lockers/showers; the most common HE subdomain was healthy options/vending. This review highlights gaps in measurement of the worksite social environment. The findings provide a useful resource for researchers and practitioners and should inform future instrument development.
Instruments to assess patient comfort during hospitalization: A psychometric review.
Lorente, Sonia; Losilla, Josep-Maria; Vives, Jaume
2018-05-01
To analyse the psychometric properties and the utility of instruments used to measure patient comfort, physical, social, psychospiritual and/or environmental, during hospitalization. There are no systematic reviews nor psychometric reviews of instruments used to measure comfort, which is considered an indicator of quality in health care associated with quicker discharges, increased patient satisfaction and better cost-benefit ratios for the institution. Psychometric review. MEDLINE, CINAHL, PsycINFO, Web of Knowledge, ProQuest Thesis&Dissertations, Google. We limited our search to studies published between 1990-2015. The psychometric analysis was performed using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN), along with the Quality Criteria for Measurement Properties. The utility of the instruments was assessed according to their cost-efficiency, acceptability and educational impact. Protocol registration in PROSPERO, CRD42016036290. Instruments reviewed showed moderate methodological quality and their utility was poorly reported. Thus, we cannot recommend any questionnaire without reservations, but the Comfort Scale, the General Comfort Questionnaire and their adaptations in adults and older patients, the Psychosocial Comfort Scale and the Incomfort des Patients de Reanimation are the most recommendable instruments to measure comfort. The methodology of the studies should be more rigorous and authors should adequately report the utility of instruments. This review provides a strategy to select the most suitable instrument to assess patient comfort according to their psychometric properties and utility, which is crucial for nurses, clinicians, researchers and institutions. © 2017 John Wiley & Sons Ltd.
A Systematic Review of Head and Neck Cancer Quality of Life Assessment Instruments
Ojo, Bukola; Genden, Eric M.; Teng, Marita S.; Milbury, Kathrin; Misiukiewicz, Krzysztof J.; Badr, Hoda
2012-01-01
Summary Although quality of life (QOL) is an important treatment outcome in head and neck cancer (HNC), cross-study comparisons have been hampered by the heterogeneity of measures used and the fact that reviews of HNC QOL instruments have not been comprehensive to date. We performed a systematic review of the published literature on HNC QOL instruments from 1990–2010, categorized, and reviewed the properties of the instruments using international guidelines as reference. Of the 2766 articles retrieved, 710 met the inclusion criteria and used 57 different head and neck-specific instruments to assess QOL. A review of the properties of these utilized measures and identification of areas in need of further research is presented. Given the volume and heterogeneity of QOL measures, there is no gold standard questionnaire. Therefore, when selecting instruments, researchers should consider not only psychometric properties but also research objectives, study design, and the pitfalls and benefits of combining different measures. Although great strides have been made in the assessment of QOL in HNC and researchers now have a plethora of quality instruments to choose from, more work is needed to improve the clinical utility of these measures in order to link QOL research to clinical practice. This review provides a platform for head and neck-specific instrument comparisons, with suggestions of important factors to consider in the systematic selection of QOL instruments, and is a first step towards translation of QOL assessment into the clinical scene. PMID:22525604
Physical activity measurement instruments for children with cerebral palsy: a systematic review.
Capio, Catherine M; Sit, Cindy H P; Abernethy, Bruce; Rotor, Esmerita R
2010-10-01
this paper is a systematic review of physical activity measurement instruments for field-based studies involving children with cerebral palsy (CP). database searches using PubMed Central, MEDLINE, CINAHL Plus, PsycINFO, EMBASE, Cochrane Library, and PEDro located 12 research papers, identifying seven instruments that met the inclusion criteria of (1) having been developed for children aged 0 to 18 years, (2) having been used to evaluate a physical activity dimension, and (3) having been used in a field-based study involving children with CP. The instruments reviewed were the Activities Scale for Kids - Performance version (ASKp), the Canada Fitness Survey, the Children's Assessment of Participation and Enjoyment/Preferences for Activities of Children (CAPE/PAC), the Compendium of Physical Activities, the Physical Activity Questionnaire - Adolescents (PAQ-A), StepWatch, and the Uptimer. Second-round searches yielded 11 more papers, providing reliability and validity evidence for the instruments. the instruments measure physical activity frequency, mode, domain, and duration. Although most instruments demonstrated adequate reliability and validity, only the ASKp and CAPE/PAC have established reliability and validity for children with physical disabilities; the Uptimer has established concurrent validity. No instrument measuring intensity in free-living has been validated or found reliable for children with CP. the findings suggest that further studies are needed to examine the methodological properties of physical activity measurement in children with CP. Combining subjective and objective instruments is recommended to achieve better understanding of physical activity participation.
Measurement technology: A compilation
NASA Technical Reports Server (NTRS)
1974-01-01
Technical information is presented on measurement techniques and instruments, measurement applications for inspection activities, measurement sensors, and data conversion methods. Photographs or diagrams are included for each instrument or method described, and where applicable, patent information is given.
NASA Technical Reports Server (NTRS)
McPeters, R.D.; Oltmans, Samuel J.
2000-01-01
NASA is creating a long term satellite ozone time series by combining data from multiple instruments: Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) (1978 - 1993), Meteor 3 TOMS (1991 - 1994), Earth Probe TOMS (1996 - present), Nimbus 7 SB-JV (1978 - 1990), NOAA-9 Solar Backscatter UV Spectrometer (SBUV/2) (1984 - 1997), NOAA-11 SBUV/2 (1989 - 1994), and NOAA-14 SBUV/2 (1995 - present). The stability of individual data sets and possible instrument-to-instrument differences are best checked by comparison with ground-based measurements. We have examined the time dependence of the calibrations of these instruments by comparing satellite derived ozone with that measured by the world primary standard Dobson spectrometer No. 83. This instrument has been maintained since 1962 as a standard for total ozone to an uncertainty of plus or minus 0.5%. Measurements of AD pair ozone made with instrument No. 83 at Mauna Loa observatory most summers since 1979 were compared with coincident TOMS and SBUV(/2) ozone measurements. The comparison shows that the various instruments were stable relative to instrument No. 83 to within about plus or minus 1%, but that there are instrument-to-instrument biases of as much as 3%. Earth Probe TOMS, for example, is 1% to 2% high relative to Nimbus 7 TOMS when the world standard instrument is used as a transfer standard. Similar results are seen when comparisons are made with an ensemble of 41 Dobson stations throughout the world, demonstrating that the ensemble as a whole is stable despite the fact that many instruments within the ensemble have clear calibration changes.
Mayer, Susanne; Paulus, Aggie T G; Łaszewska, Agata; Simon, Judit; Drost, Ruben M W A; Ruwaard, Dirk; Evers, Silvia M A A
2017-09-01
Intersectoral costs and benefits (ICBs), i.e. costs and benefits of healthcare interventions outside the healthcare sector, can be a crucial component in economic evaluations from the societal perspective. Pivotal to their estimation is the existence of sound resource-use measurement (RUM) instruments; however, RUM instruments for ICBs in the education or criminal justice sectors have not yet been systematically collated or their psychometric quality assessed. This review aims to fill this gap. To identify relevant instruments, the Database of Instruments for Resource Use Measurement (DIRUM) was searched. Additionally, a systematic literature review was conducted in seven electronic databases to detect instruments containing ICB items used in economic evaluations. Finally, studies evaluating the psychometric quality of these instruments were searched. Twenty-six unique instruments were included. Most frequently, ICB items measured school absenteeism, tutoring, classroom assistance or contacts with legal representatives, police custody/prison detainment and court appearances, with the highest number of items listed in the Client Service Receipt Inventory/Client Sociodemographic and Service Receipt Inventory/Client Service Receipt Inventory-Children's Version (CSRI/CSSRI/CSRI-C), Studying the Scope of Parental Expenditures (SCOPE) and Self-Harm Intervention, Family Therapy (SHIFT) instruments. ICBs in the education sector were especially relevant for age-related developmental disorders and chronic diseases, while criminal justice resource use seems more important in mental health, including alcohol-related disorders or substance abuse. Evidence on the validity or reliability of ICB items was published for two instruments only. With a heterogeneous variety of ICBs found to be relevant for several disease areas but many ICB instruments applied in one study only (21/26 instruments), setting-up an international task force to, for example, develop an internationally adaptable instrument is recommended.
Dötsch, J; Demirakça, S; Hahn, D; Katz, N; Kühl, P G; Rascher, W
1999-06-01
During nitric oxide inhalation, methemoglobinemia needs to be monitored. We compared six commercially available instruments and one manual method for methemoglobin measurements. In addition, we studied whether and to what degree methylene blue interferes with methemoglobin measurements. In vitro methodologic study. Research laboratory in a university hospital. Five healthy volunteers from whom red blood cells were obtained. Methemoglobinemia was generated in a red blood cell suspension by nitric oxide; methemoglobin was measured with six commercial instruments and one manual photometric method to calculate variation coefficients and to determine the differences between the devices. Methemoglobin was measured with and without the addition of methylene blue with two instruments. Measurements were performed immediately after the addition of methylene blue. All six commercially available instruments had variation coefficients of <0.1 at methemoglobin concentrations of 5%, whereas the manual photometric method did not reach a variation coefficient of <0.1 at 8% of methemoglobin. Apart from two devices that measured slightly but significantly higher methemoglobin levels, all instruments measured similar values of methemoglobin when the same samples were determined simultaneously. Higher concentrations of methylene blue (10, 40, 100 microM) reduced substantially the apparent concentrations of methemoglobin. Interference by methylene blue was most pronounced at low methemoglobin levels. With some limitations, all commercial instruments that were tested performed adequately for the monitoring of methemoglobinemia. Methylene blue interferes with the methemoglobin measurements in a dose-dependent manner.
Comparison of two scanning instruments to measure peripheral refraction in the human eye.
Jaeken, Bart; Tabernero, Juan; Schaeffel, Frank; Artal, Pablo
2012-03-01
To better understand how peripheral refraction affects development of myopia in humans, specialized instruments are fundamental for precise and rapid measurements of refraction over the visual field. We compare here two prototype instruments that measure in a few seconds the peripheral refraction in the eye with high angular resolution over a range of about ±45 deg. One instrument is based on the continuous recording of Hartmann-Shack (HS) images (HS scanner) and the other is based on the photorefraction (PR) principle (PR scanner). On average, good correlations were found between the refraction results provided by the two devices, although it varied across subjects. A detailed statistical analysis of the differences between both instruments was performed based on measurements in 35 young subjects. Both instruments have advantages and disadvantages. The HS scanner also provides the high-order aberration data, while the PR scanner is more compact and has a lower cost. Both instruments are current prototypes, and further optimization is possible to make them even more suitable tools for future visual optics and myopia research and also for different ophthalmic applications.
Note: Measuring instrument of singlet oxygen quantum yield in photodynamic effects
NASA Astrophysics Data System (ADS)
Li, Zhongwei; Zhang, Pengwei; Zang, Lixin; Qin, Feng; Zhang, Zhiguo; Zhang, Hongli
2017-06-01
Using diphenylisobenzofuran (C20H14O) as a singlet oxygen (1O2) reporter, a comparison method, which can be used to measure the singlet oxygen quantum yield (ΦΔ) of the photosensitizer quantitatively, is presented in this paper. Based on this method, an automatic measuring instrument of singlet oxygen quantum yield is developed. The singlet oxygen quantum yield of the photosensitizer hermimether and aloe-emodin is measured. It is found that the measuring results are identical to the existing ones, which verifies the validity of the measuring instrument.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The following are covered: the Sun and its radiation, solar radiation and atmospheric interaction, solar radiation measurement methods, spectral irradiance measurements of natural sources, the measurement of infrared radiation, the measurement of circumsolar radiation, some empirical properties of solar radiation and related parameters, duration of sunshine, and meteorological variables related to solar energy. Included in appendices are manufacturers and distributors of solar radiation measuring instruments and an approximate method for quality control of solar radiation instruments. (MHR)
Assessing reliability and validity measures in managed care studies.
Montoya, Isaac D
2003-01-01
To review the reliability and validity literature and develop an understanding of these concepts as applied to managed care studies. Reliability is a test of how well an instrument measures the same input at varying times and under varying conditions. Validity is a test of how accurately an instrument measures what one believes is being measured. A review of reliability and validity instructional material was conducted. Studies of managed care practices and programs abound. However, many of these studies utilize measurement instruments that were developed for other purposes or for a population other than the one being sampled. In other cases, instruments have been developed without any testing of the instrument's performance. The lack of reliability and validity information may limit the value of these studies. This is particularly true when data are collected for one purpose and used for another. The usefulness of certain studies without reliability and validity measures is questionable, especially in cases where the literature contradicts itself
The FIELDS Instrument Suite for Solar Probe Plus
NASA Technical Reports Server (NTRS)
Bale, S. D.; Goetz, K.; Harvey, P. R.; Turin, P.; Bonnell, J. W.; Dudok de Wit, T.; Ergun, R. E.; MacDowall, R. J.; Pulupa, M.; Andre, M.;
2016-01-01
NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.
The FIELDS Instrument Suite for Solar Probe Plus
Goetz, K.; Harvey, P.R.; Turin, P.; Bonnell, J.W.; de Wit, T. Dudok; Ergun, R.E.; MacDowall, R.J.; Pulupa, M.; Andre, M.; Bolton, M.; Bougeret, J.-L.; Bowen, T.A.; Burgess, D.; Cattell, C.A.; Chandran, B.D.G.; Chaston, C.C.; Chen, C.H.K.; Choi, M.K.; Connerney, J.E.; Cranmer, S.; Diaz-Aguado, M.; Donakowski, W.; Drake, J.F.; Farrell, W.M.; Fergeau, P.; Fermin, J.; Fischer, J.; Fox, N.; Glaser, D.; Goldstein, M.; Gordon, D.; Hanson, E.; Harris, S.E.; Hayes, L.M.; Hinze, J.J.; Hollweg, J.V.; Horbury, T.S.; Howard, R. A.; Hoxie, V.; Jannet, G.; Karlsson, M.; Kasper, J.C.; Kellogg, P.J.; Kien, M.; Klimchuk, J.A.; Krasnoselskikh, V.V.; Krucker, S.; Lynch, J.J.; Maksimovic, M.; Malaspina, D.M.; Marker, S.; Martin, P.; Martinez-Oliveros, J.; McCauley, J.; McComas, D.J.; McDonald, T.; Meyer-Vernet, N.; Moncuquet, M.; Monson, S.J.; Mozer, F.S.; Murphy, S.D.; Odom, J.; Oliverson, R.; Olson, J.; Parker, E.N.; Pankow, D.; Phan, T.; Quataert, E.; Quinn, T.; Ruplin, S.W.; Salem, C.; Seitz, D.; Sheppard, D.A.; Siy, A.; Stevens, K.; Summers, D.; Szabo, A.; Timofeeva, M.; Vaivads, A.; Velli, M.; Yehle, A.; Werthimer, D.; Wygant, J.R.
2018-01-01
NASA’s Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products. PMID:29755144
New type of measuring and intelligent instrument for curing tobacco
NASA Astrophysics Data System (ADS)
Yi, Chui-Jie; Huang, Xieqing; Chen, Tianning; Xia, Hong
1993-09-01
A new type of measuring intelligent instrument for cured tobacco is presented in this paper. Based on fuzzy linguistic control principles the instrument is used to controlling the temperature and humidity during cured tobacco taking 803 1 singlechip computer as a center controller. By using methods of fuzzy weighted factors the cross coupling in curing procedures is decoupled. Results that the instrument has producted indicate the fuzzy controller in the instrument has perfect performance for process of cured tobacco as shown in figure
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...
Foundations of measurement and instrumentation
NASA Technical Reports Server (NTRS)
Warshawsky, Isidore
1990-01-01
The user of instrumentation has provided an understanding of the factors that influence instrument performance, selection, and application, and of the methods of interpreting and presenting the results of measurements. Such understanding is prerequisite to the successful attainment of the best compromise among reliability, accuracy, speed, cost, and importance of the measurement operation in achieving the ultimate goal of a project. Some subjects covered are dimensions; units; sources of measurement error; methods of describing and estimating accuracy; deduction and presentation of results through empirical equations, including the method of least squares; experimental and analytical methods of determining the static and dynamic behavior of instrumentation systems, including the use of analogs.
Double-Pulse Two-Micron IPDA Lidar Simulation for Airborne Carbon Dioxide Measurements
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Singh, Upendra N.; Yu, Jirong; Petros, Mulugeta
2015-01-01
An advanced double-pulsed 2-micron integrated path differential absorption lidar has been developed at NASA Langley Research Center for measuring atmospheric carbon dioxide. The instrument utilizes a state-of-the-art 2-micron laser transmitter with tunable on-line wavelength and advanced receiver. Instrument modeling and airborne simulations are presented in this paper. Focusing on random errors, results demonstrate instrument capabilities of performing precise carbon dioxide differential optical depth measurement with less than 3% random error for single-shot operation from up to 11 km altitude. This study is useful for defining CO2 measurement weighting, instrument setting, validation and sensitivity trade-offs.
Vessey, Judith; Strout, Tania D; DiFazio, Rachel L; Walker, Allison
2014-12-01
Bullying is a significant problem in schools and measuring this concept remains problematic. The purposes of this study were to (1) identify the published self-report measures developed to assess youth bullying; (2) evaluate their psychometric properties and instrument characteristics; and (3) evaluate the quality of identified psychometric papers evaluating youth bullying measures. A systematic review of the literature was conducted using 4 electronic databases. Data extraction and appraisal of identified instruments were completed using a standardized method and Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Thirty-one articles describing 27 self-report instruments were evaluated in our analysis. Quality assessments ranged from 18% to 91%, with 6 papers reaching or exceeding a quality score of 75%. Limited evidence supporting the reliability, validity, and responsiveness of existing youth bullying measures was identified. Evidence supporting the psychometric soundness of the instruments identified was limited. Many measures were in early development and additional evaluation is necessary to validate their psychometric properties. A pool of instruments possesses acceptable initial psychometric dependability for selected assessment purposes. These findings have significant implications for assessing youth bullying and designing and evaluating school-based interventions. © 2014, American School Health Association.
Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.
Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R
2005-11-01
An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.
Wettability measurement apparatus for porous material using the modified Washburn method
NASA Astrophysics Data System (ADS)
Thakker, Manish; Karde, Vikram; Shah, Dinesh O.; Shukla, Premal; Ghoroi, Chinmay
2013-12-01
In this work a cost-effective instrument for measuring the wettability of powder materials was designed and developed, which works on the modified Washburn method. The instrument measures the mass gain against time due to penetration of the liquid into the powder materials using a microbalance and LabVIEW-based data acquisition system. The wettability characteristic of different powders was determined from the contact angle using the modified Washburn equation. To demonstrate the performance of the developed instrument, the wettability of as-received corn starch and nano-coated corn starch powders was estimated with water as a test liquid. The corn starch powders coated with hydrophilic grade (Aerosil 200P) and hydrophobic grade (Aerosil R972) nanoparticles at different coating levels showed expected changes in their contact angle. Some of the results were also verified against the available standard instrument for wettability measurement and found to be consistent. The present configuration of the instrument costs about 500 US which is 15 to 20 times less than the available advanced models. The developed instrument is thus a cost-effective solution for wettability measurement which can be used for materials in food processing, pharmaceuticals, horticulture, textile manufacturing, civil engineering etc. The developed instrument is expected to help many small scale industries or research labs who cannot afford an expensive instrument for wettability studies.
Psychometric Principles in Measurement for Geoscience Education Research: A Climate Change Example
NASA Astrophysics Data System (ADS)
Libarkin, J. C.; Gold, A. U.; Harris, S. E.; McNeal, K.; Bowles, R.
2015-12-01
Understanding learning in geoscience classrooms requires that we use valid and reliable instruments aligned with intended learning outcomes. Nearly one hundred instruments assessing conceptual understanding in undergraduate science and engineering classrooms (often called concept inventories) have been published and are actively being used to investigate learning. The techniques used to develop these instruments vary widely, often with little attention to psychometric principles of measurement. This paper will discuss the importance of using psychometric principles to design, evaluate, and revise research instruments, with particular attention to the validity and reliability steps that must be undertaken to ensure that research instruments are providing meaningful measurement. An example from a climate change inventory developed by the authors will be used to exemplify the importance of validity and reliability, including the value of item response theory for instrument development. A 24-item instrument was developed based on published items, conceptions research, and instructor experience. Rasch analysis of over 1000 responses provided evidence for the removal of 5 items for misfit and one item for potential bias as measured via differential item functioning. The resulting 18-item instrument can be considered a valid and reliable measure based on pre- and post-implementation metrics. Consideration of the relationship between respondent demographics and concept inventory scores provides unique insight into the relationship between gender, religiosity, values and climate change understanding.
Rapid Measurement Of Asbestos Content Of Building Materials
NASA Technical Reports Server (NTRS)
Weiss, James R.; Grove, Cindy I.; Hoover, Gordon L.; Stephens, James B.
1994-01-01
Portable instrument measures asbestos content of construction materials in place. Helps building renovators determine, quickly and accurately, whether asbestos is present. Concept readily adapted to special-purpose, battery-powered instrument. Contractor using such instrument could obtain reliable information on asbestos content in minutes.
Accommodating subject and instrument variations in spectroscopic determinations
Haas, Michael J [Albuquerque, NM; Rowe, Robert K [Corrales, NM; Thomas, Edward V [Albuquerque, NM
2006-08-29
A method and apparatus for measuring a biological attribute, such as the concentration of an analyte, particularly a blood analyte in tissue such as glucose. The method utilizes spectrographic techniques in conjunction with an improved instrument-tailored or subject-tailored calibration model. In a calibration phase, calibration model data is modified to reduce or eliminate instrument-specific attributes, resulting in a calibration data set modeling intra-instrument or intra-subject variation. In a prediction phase, the prediction process is tailored for each target instrument separately using a minimal number of spectral measurements from each instrument or subject.
Optical radiation measurements and instrumentation.
Andersen, F A; Landry, R J
1981-07-01
Accurate measurement of optical radiation is required when sources of optical radiation are used in biological research. Such measurement of broad-band noncoherent optical radiations usually must be performed by a highly trained specialist using sophisticated, complex, and expensive instruments. Presentation of the results of such measurement requires correct use of quantities and units with which many biological researchers are unfamiliar. The measurement process, quantities, units, measurement systems and instruments, and uncertainties associated with optical radiation measurements are reviewed in this paper. A conventional technique for evaluating the potential hazards associated with broad-band sources of optical radiation and a spectroradiometer developed to measure spectral quantities is described. A new prototype ultraviolet radiation hazard monitor which has recently been developed is also presented. This new instrument utilizes a spectrograph and a spectral weighting mechanical mask and provides a direct reading of the effective irradiance for wavelengths less than 315 nm.
True Airspeed Measurement by Ionization-Tracer Technique
NASA Technical Reports Server (NTRS)
Boyd, B.; Dorsch, R. G.; Brodie, G. H.
1952-01-01
Ion bundles produced in a pulse-excited corona discharge are used as tracers with a radar-like pulse transit-time measuring instrument in order to provide a measurement of airspeed that is independent of all variables except time and distance. The resulting instrumentation need not project into the air stream and, therefore, will not cause any interference in supersonic flow. The instrument was tested at Mach numbers ranging from 0.3 to 3.8. Use of the proper instrumentation and technique results in accuracy of the order of 1 percent.
Integration and Testing of Miniaturized Volcanic Gas-Sensing Instruments on UAS Platforms
NASA Astrophysics Data System (ADS)
Lopez, T. M.; Kern, C.; Diaz, J. A.; Vanderwaal, S. J.; Levy, A.
2015-12-01
Volcanologists measure the concentrations and emission rates of gases emitted from active volcanoes to understand magmatic processes, which aids in eruption forecasting, and to evaluate air quality for human and environmental health. Both of these applications become particularly important during periods of unusually high volcanic unrest when it is typically hazardous to approach a given volcano. Unmanned aerial systems (UASs) represent a promising platform for continued gas measurements during unrest, while reducing the risk to volcanologists. Two miniature gas-sensing instruments have been developed specifically for integration onto small UAS platforms. Both instruments weigh 1 kg or less, including integrated power. The microDOAS instrument is an upward-looking UV/vis spectrometer that measures the spectral absorption signature of SO2 and certain halogen oxides in scattered solar radiation. By flying beneath a volcanic plume, the instrument can measure the SO2 content in the plume cross-section which can be used to determine the SO2 emission rate. The miniGas instrument is flown within the volcanic plume and records in situ concentrations of CO2, SO2 and H2S, as well as atmospheric temperature, pressure, relative humidity and GPS location. All data are telemetered back to the base station to immediately alert the operator of potentially hazardous conditions. Both instruments have been successfully tested at active volcanoes in Alaska and Costa Rica and were integrated onto small ACUASI Ptarmigan hexacopters. A test mission was conducted at the Poker Flat Research Range in Alaska. During this experiment both instruments were successfully flown in flight patterns typical of manned volcanic gas measurements and new UAV-specific measurement strategies were developed. Here we describe the instruments and platforms employed, our experimental results and observations, and make recommendations for application to volcanic settings.
Lami, Francesca; Egberts, Kristine; Ure, Alexandra; Conroy, Rowena; Williams, Katrina
2018-03-01
To systematically review the measurement properties of instruments assessing participation in young people with autism spectrum disorder (ASD). A search was performed in MEDLINE, PsycINFO, and PubMed combining three constructs ('ASD', 'test of participation', 'measurement properties'). Results were restricted to articles including people aged 6 to 29 years. The 2539 identified articles were independently screened by two reviewers. For the included articles, data were extracted using standard forms and their risk of bias was assessed. Nine studies (8 cross-sectional) met the inclusion criteria, providing information on seven different instruments. The total sample included 634 participants, with sex available for 600 (males=494; females=106) and age available for 570, with mean age for these participants 140.58 months (SD=9.11; range=36-624). Included instruments were the school function assessment, vocational index, children's assessment of participation and enjoyment/preferences for activities of children, experience sampling method, Pediatric Evaluation of Disability Inventory, Computer Adaptive Test, adolescent and young adult activity card sort, and Patient-Reported Outcomes Measurement Information System parent-proxy peer relationships. Seven studies assessed reliability and validity; good properties were reported for half of the instruments considered. Most studies (n=6) had high risk of bias. Overall the quality of the evidence for each tool was limited. Validation of these instruments, or others that comprehensively assess participation, is needed. Future studies should follow recommended methodological standards. Seven instruments have been used to assess participation in young people with autism. One instrument, with excellent measurement properties in one study, does not comprehensively assess participation. Studies of three instruments that incorporate a more comprehensive assessment of participation have methodological limitations. Overall, limited evidence exists regarding measurement properties of participation assessments for young people with autism. © 2017 Mac Keith Press.
Li, Honghe; Liu, Yang; Wen, Deliang
2017-01-01
Background Over the last three decades, various instruments were developed and employed to assess medical professionalism, but their measurement properties have yet to be fully evaluated. This study aimed to systematically evaluate these instruments’ measurement properties and the methodological quality of their related studies within a universally acceptable standardized framework and then provide corresponding recommendations. Methods A systematic search of the electronic databases PubMed, Web of Science, and PsycINFO was conducted to collect studies published from 1990–2015. After screening titles, abstracts, and full texts for eligibility, the articles included in this study were classified according to their respective instrument’s usage. A two-phase assessment was conducted: 1) methodological quality was assessed by following the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist; and 2) the quality of measurement properties was assessed according to Terwee’s criteria. Results were integrated using best-evidence synthesis to look for recommendable instruments. Results After screening 2,959 records, 74 instruments from 80 existing studies were included. The overall methodological quality of these studies was unsatisfactory, with reasons including but not limited to unknown missing data, inadequate sample sizes, and vague hypotheses. Content validity, cross-cultural validity, and criterion validity were either unreported or negative ratings in most studies. Based on best-evidence synthesis, three instruments were recommended: Hisar’s instrument for nursing students, Nurse Practitioners’ Roles and Competencies Scale, and Perceived Faculty Competency Inventory. Conclusion Although instruments measuring medical professionalism are diverse, only a limited number of studies were methodologically sound. Future studies should give priority to systematically improving the performance of existing instruments and to longitudinal studies. PMID:28498838
NASA Astrophysics Data System (ADS)
Korhonen, Rami K.; Saarakkala, Simo; Töyräs, Juha; Laasanen, Mikko S.; Kiviranta, Ilkka; Jurvelin, Jukka S.
2003-06-01
Softening of articular cartilage, mainly attributable to deterioration of superficial collagen network and depletion of proteoglycans, is a sign of incipient osteoarthrosis. Early diagnosis of osteoarthrosis is essential to prevent the further destruction of the tissue. During the past decade, a few arthroscopic instruments have been introduced for the measurement of cartilage stiffness; these can be used to provide a sensitive measure of cartilage status. Ease of use, accuracy and reproducibility of the measurements as well as a low risk of damaging cartilage are the main qualities needed in any clinically applicable instrument. In this study, we have modified a commercially available arthroscopic indentation instrument to better fulfil these requirements when measuring cartilage stiffness in joints with thin cartilage. Our novel configuration was validated by experimental testing as well as by finite element (FE) modelling. Experimental and numerical tests indicated that it would be better to use a smaller reference plate and a lower pressing force (3 N) than those used in the original instrument (7-10 N). The reproducibility (CV = 5.0%) of the in situ indentation measurements was improved over that of the original instrument (CV = 7.6%), and the effect of material thickness on the indentation response was smaller than that obtained with the original instrument. The novel configuration showed a significant linear correlation between the indenter force and the reference dynamic modulus of cartilage in unconfined compression, especially in soft tissue (r = 0.893, p < 0.001, n = 16). FE analyses with a transversely isotropic poroelastic model indicated that the instrument was suitable for detecting the degeneration of superficial cartilage. In summary, the instrument presented in this study allows easy and reproducible measurement of cartilage stiffness, also in thin cartilage, and therefore represents a technical improvement for the early diagnosis of osteoarthrosis during arthroscopy.
Dieppe, Paul
2016-01-01
Objective Investigators within many disciplines are using measures of well-being, but it is not always clear what they are measuring, or which instruments may best meet their objectives. The aims of this review were to: systematically identify well-being instruments, explore the variety of well-being dimensions within instruments and describe how the production of instruments has developed over time. Design Systematic searches, thematic analysis and narrative synthesis were undertaken. Data sources MEDLINE, EMBASE, EconLit, PsycINFO, Cochrane Library and CINAHL from 1993 to 2014 complemented by web searches and expert consultations through 2015. Eligibility criteria Instruments were selected for review if they were designed for adults (≥18 years old), generic (ie, non-disease or context specific) and available in an English version. Results A total of 99 measures of well-being were included, and 196 dimensions of well-being were identified within them. Dimensions clustered around 6 key thematic domains: mental well-being, social well-being, physical well-being, spiritual well-being, activities and functioning, and personal circumstances. Authors were rarely explicit about how existing theories had influenced the design of their tools; however, the 2 most referenced theories were Diener's model of subjective well-being and the WHO definition of health. The period between 1990 and 1999 produced the greatest number of newly developed well-being instruments (n=27). An illustration of the dimensions identified and the instruments that measure them is provided within a thematic framework of well-being. Conclusions This review provides researchers with an organised toolkit of instruments, dimensions and an accompanying glossary. The striking variability between instruments supports the need to pay close attention to what is being assessed under the umbrella of ‘well-being’ measurement. PMID:27388349
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, A.C.; Knutson, E.O.; Tu, K.W.
1995-12-01
The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC).more » There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is <5,000 cm{sup -3}.« less
ERIC Educational Resources Information Center
de l'Eau, Jacquelyn
2017-01-01
The purpose of this study was to examine the construct validity of social loafing using convergent and discriminant validity principles. Three instruments that purport to measure social loafing were factor analyzed: A ten-item instrument by George (1992), a 13-item instrument by Mulvey and Klein (1998), and a 22-item instrument by Jassawalla,…
Instruments to measure social support and related constructs in pregnant adolescents: a review.
Perrin, K M; McDermott, R J
1997-01-01
This review examines some of the key issues related to measuring social support and identifies 28 instruments which have been used in research with pregnant adolescents. The major external and internal variables that affect social support for pregnant adolescents are defined. Relevant questions are offered to guide the researcher in the choice of a social support instrument, and the 28 social support instruments are described by author, availability, length and item type, psychometric properties, and selected references and notes. Although not an exhaustive list, these 28 instruments are representative of the broad spectrum of measurement tools available which were chosen because they have been used in a variety of social support research endeavors.
Casas, Francisco J.; Ortiz, David; Villa, Enrique; Cano, Juan L.; Cagigas, Jaime; Pérez, Ana R.; Aja, Beatriz; Terán, J. Vicente; de la Fuente, Luisa; Artal, Eduardo; Hoyland, Roger; Génova-Santos, Ricardo
2015-01-01
This paper presents preliminary polarization measurements and systematic-error characterization of the Thirty Gigahertz Instrument receiver developed for the QUIJOTE experiment. The instrument has been designed to measure the polarization of Cosmic Microwave Background radiation from the sky, obtaining the Q, U, and I Stokes parameters of the incoming signal simultaneously. Two kinds of linearly polarized input signals have been used as excitations in the polarimeter measurement tests in the laboratory; these show consistent results in terms of the Stokes parameters obtained. A measurement-based systematic-error characterization technique has been used in order to determine the possible sources of instrumental errors and to assist in the polarimeter calibration process. PMID:26251906
Selected Instrumentation Films, 1969-1970.
ERIC Educational Resources Information Center
Simmons, Raymond L., Ed.
This list of currently available films and filmstrips pertinent to instrumentation has been compiled from information solicited from many government and private sources. The 1969 compilation has been organized into the following eight categories: (1) principles of measurement and basic measurements; (2) analysis instrumentation; (3) automation and…
Instrument accurately measures weld angle and offset
NASA Technical Reports Server (NTRS)
Boyd, W. G.
1967-01-01
Weld angle is measured to the nearest arc minute and offset to one thousandth of an inch by an instrument designed to use a reference plane at two locations on a test coupon. A special table for computation has been prepared for use with the instrument.
Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging
Stoll, Jeffrey; Ren, Hongliang; Dupont, Pierre E.
2013-01-01
A family of passive echogenic markers is presented by which the position and orientation of a surgical instrument can be determined in a 3-D ultrasound volume, using simple image processing. Markers are attached near the distal end of the instrument so that they appear in the ultrasound volume along with the instrument tip. They are detected and measured within the ultrasound image, thus requiring no external tracking device. This approach facilitates imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument pose can be used in augmented reality displays or for image-based servoing. Design principles for marker shapes are presented that ensure imaging system and measurement uniqueness constraints are met. An error analysis is included that can be used to guide marker design and which also establishes a lower bound on measurement uncertainty. Finally, examples of marker measurement and tracking algorithms are presented along with experimental validation of the concepts. PMID:22042148
Diode laser-based cavity ring-down instrument for NO3, N2O5, NO, NO2 and O3 from aircraft
NASA Astrophysics Data System (ADS)
Wagner, N. L.; Dubé, W. P.; Washenfelder, R. A.; Young, C. J.; Pollack, I. B.; Ryerson, T. B.; Brown, S. S.
2011-06-01
This article presents a diode laser-based, cavity ring-down spectrometer for simultaneous in situ measurements of four nitrogen oxide species, NO3, N2O5, NO, NO2, as well as O3, designed for deployment on aircraft. The instrument measures NO3 and NO2 by optical extinction at 662 nm and 405 nm, respectively; N2O5 is measured by thermal conversion to NO3, while NO and O3 are measured by chemical conversion to NO2. The instrument has several advantages over previous instruments developed by our group for measurement of NO2, NO3 and N2O5 alone, based on a pulsed Nd:YAG and dye laser. First, the use of continuous wave diode lasers reduces the requirements for power and weight and eliminates hazardous materials. Second, detection of NO2 at 405 nm is more sensitive than our previously reported 532 nm instrument, and does not have a measurable interference from O3. Third, the instrument includes chemical conversion of NO and O3 to NO2 to provide measurements of total NOx (= NO + NO2) and Ox (= NO2 + O3) on two separate channels; mixing ratios of NO and O3 are determined by subtraction of NO2. Finally, all five species are calibrated against a single standard based on 254 nm O3 absorption to provide high accuracy. Disadvantages include an increased sensitivity to water vapor on the 662 nm NO3 and N2O5 channels and a modest reduction in sensitivity for these species compared to the pulsed laser instrument. The in-flight detection limit for both NO3 and N2O5 is 3 pptv (2 σ, 1 s) and for NO, NO2 and O3 is 140, 90, and 120 pptv (2 σ, 1 s) respectively. Demonstrated performance of the instrument in a laboratory/ground based environment is better by approximately a factor of 2-3. The NO and NO2 measurements are less precise than research-grade chemiluminescence instruments. However, the combination of these five species in a single instrument, calibrated to a single analytical standard, provides a complete and accurate picture of nighttime nitrogen oxide chemistry. The instrument performance is demonstrated using data acquired during a recent field campaign in California.
Designing communication and remote controlling of virtual instrument network system
NASA Astrophysics Data System (ADS)
Lei, Lin; Wang, Houjun; Zhou, Xue; Zhou, Wenjian
2005-01-01
In this paper, a virtual instrument network through the LAN and finally remote control of virtual instruments is realized based on virtual instrument and LabWindows/CVI software platform. The virtual instrument network system is made up of three subsystems. There are server subsystem, telnet client subsystem and local instrument control subsystem. This paper introduced virtual instrument network structure in detail based on LabWindows. Application procedure design of virtual instrument network communication, the Client/the programming mode of the server, remote PC and server communication far realizing, the control power of the workstation is transmitted, server program and so on essential technical were introduced. And virtual instruments network may connect to entire Internet on. Above-mentioned technology, through measuring the application in the electronic measurement virtual instrument network that is already built up, has verified the actual using value of the technology. Experiment and application validate that this design is resultful.
Development of a computer-assisted system for model-based condylar position analysis (E-CPM).
Ahlers, M O; Jakstat, H
2009-01-01
Condylar position analysis is a measuring method for the three-dimensional quantitative acquisition of the position of the mandible in different conditions or at different points in time. Originally, the measurement was done based on a model, using special mechanical condylar position measuring instruments, and on a research scale with mechanical-electronic measuring instruments. Today, as an alternative, it is possible to take measurements with electronic measuring instruments applied directly to the patient. The computerization of imaging has also facilitated condylar position measurement by means of three-dimensional data records obtained by imaging examination methods, which has been used in connection with the simulation and quantification of surgical operation results. However, the comparative measurement of the condylar position at different points in time has so far not been possible to the required degree. An electronic measuring instrument, allowing acquisition of the condylar position in clinical routine and facilitating later calibration with measurements from later examinations by data storage and use of precise equalizing systems, was therefore designed by the present authors. This measuring instrument was implemented on the basis of already existing components from the Reference CPM und Cadiax Compact articulator and registration systems (Gamma Dental, Klosterneuburg, Austria) as well as the matching CMD3D evaluation software (dentaConcept, Hamburg).
A review of health-related workplace productivity loss instruments.
Lofland, Jennifer H; Pizzi, Laura; Frick, Kevin D
2004-01-01
The objective of this review was to identify health-related workplace productivity loss survey instruments, with particular emphasis on those that capture a metric suitable for direct translation into a monetary figure. A literature search using Medline, HealthSTAR, PsycINFO and Econlit databases between 1966 and 2002, and a telephone-administered survey of business leaders and researchers, were conducted to identify health-related workplace productivity measurement survey instruments. This review was conducted from the societal perspective. Each identified instrument was reviewed for the following: (i). reliability; (ii). content validity; (iii). construct validity; (iv). criterion validity; (v). productivity metric(s); (vi). instrument scoring technique; (vii). suitability for direct translation into a monetary figure; (viii). number of items; (ix). mode(s) of administration; and (x). disease state(s) in which it had been tested. Reliability and validity testing have been performed for 8 of the 11 identified surveys. Of the 11 instruments identified, six captured metrics that are suitable for direct translation into a monetary figure. Of those six, one instrument measured absenteeism, while the other five measured both absenteeism and presenteeism. All of the identified instruments except for one were available as paper, self-administered questionnaires and many were available in languages other than English. This review provides a comprehensive overview of the published, peer-reviewed survey instruments available to measure health-related workplace productivity loss. As the field of productivity measurement matures, tools may be developed that will allow researchers to accurately calculate lost productivity costs when performing cost-effectiveness and cost-benefit analyses. Using data captured by these instruments, society and healthcare decision makers will be able to make better informed decisions concerning the value of the medications, disease management and health promotion programmes that individuals receive.
Comparative measurements using different particle size instruments
NASA Technical Reports Server (NTRS)
Chigier, N.
1984-01-01
This paper discusses the measurement and comparison of particle size and velocity measurements in sprays. The general nature of sprays and the development of standard, consistent research sprays are described. The instruments considered in this paper are: pulsed laser photography, holography, television, and cinematography; laser anemometry and interferometry using visibility, peak amplitude, and intensity ratioing; and laser diffraction. Calibration is by graticule, reticle, powders with known size distributions in liquid cells, monosize sprays, and, eventually, standard sprays. Statistical analyses including spatial and temporal long-time averaging as well as high-frequency response time histories with conditional sampling are examined. Previous attempts at comparing instruments, the making of simultaneous or consecutive measurements with similar types and different types of imaging, interferometric, and diffraction instruments are reviewed. A program of calibration and experiments for comparing and assessing different instruments is presented.
Instruments for measuring the amount of moisture in the air
NASA Technical Reports Server (NTRS)
Johnson, D. L.
1978-01-01
A summarization and discussion of the many systems available for measuring moisture in the atmosphere is presented. Conventional methods used in the field of meteorology and methods used in the laboratory are discussed. Performance accuracies, and response of the instruments were reviewed as well as the advantages and disadvantages of each. Methods of measuring humidity aloft by instrumentation onboard aircraft and balloons are given, in addition to the methods used to measure moisture at the Earth's surface.
2011-01-01
Objective To evaluate the validity of cancer-specific and generic preference-based instruments to discriminate across different measures of cancer severities. Methods Patients with breast (n = 66), colorectal (n = 57), and lung (n = 61) cancer completed the EORTC QLQ-C30 and the FACT-G, as well as three generic instruments: the EQ-5D, the SF-6D, and the HUI2/3. Disease severity was quantified using cancer stage, Eastern Cooperative Oncology Group Performance Status (ECOG-PS) score, and self-reported health status. Comparative analyses confirmed the multi-dimensional conceptualization of the instruments in terms of construct and convergent validity. Results In general, the instruments were able to discriminate across severity measures. The instruments demonstrated moderate to strong correlation with each other (r = 0.37-0.73). Not all of the measures could discriminate between different groups of disease severity: the EQ-5D and SF-6D were less discriminative than the HUI2/3 and the cancer-specific instruments. Conclusion The cancer-specific and generic preference-based instruments demonstrated to be valid in discriminating across levels of ECOG-PS scores and self-reported health states. However, the usefulness of the generic instruments may be limited if they are not able to detect small changes in health status within cancer patients. This raises concerns regarding the appropriateness of these instruments when comparing different cancer treatments within an economic evaluation framework. PMID:22123196
Ebrahim, Shanil; Johnston, Bradley C; Akl, Elie A; Mustafa, Reem A; Sun, Xin; Walter, Stephen D; Heels-Ansdell, Diane; Alonso-Coello, Pablo; Guyatt, Gordon H
2014-05-01
We previously developed an approach to address the impact of missing participant data in meta-analyses of continuous variables in trials that used the same measurement instrument. We extend this approach to meta-analyses including trials that use different instruments to measure the same construct. We reviewed the available literature, conducted an iterative consultative process, and developed an approach involving a complete-case analysis complemented by sensitivity analyses that apply a series of increasingly stringent assumptions about results in patients with missing continuous outcome data. Our approach involves choosing the reference measurement instrument; converting scores from different instruments to the units of the reference instrument; developing four successively more stringent imputation strategies for addressing missing participant data; calculating a pooled mean difference for the complete-case analysis and imputation strategies; calculating the proportion of patients who experienced an important treatment effect; and judging the impact of the imputation strategies on the confidence in the estimate of effect. We applied our approach to an example systematic review of respiratory rehabilitation for chronic obstructive pulmonary disease. Our extended approach provides quantitative guidance for addressing missing participant data in systematic reviews of trials using different instruments to measure the same construct. Copyright © 2014 Elsevier Inc. All rights reserved.
Chang, Hsueh-Yuan; Vickers, Zata M; Tong, Cindy B S
2018-04-01
Loss of crispness in apple fruit during storage reduces the fruit's fresh sensation and consumer acceptance. Apple varieties that maintain crispness thus have higher potential for longer-term consumer appeal. To efficiently phenotype crispness, several instrumental methods have been tested, but variable results were obtained when different apple varieties were assayed. To extend these studies, we assessed the extent to which instrumental measurements correlate to and predict sensory crispness, with a focus on crispness maintenance. We used an apple breeding family derived from a cross between "Honeycrisp" and "MN1764," which segregates for crispness maintenance. Three types of instrumental measurements (puncture, snapping, and mechanical-acoustic tests) and sensory evaluation were performed on fruit at harvest and after 8 weeks of cold storage. Overall, 20 genotypes from the family and the 2 parents were characterized by 19 force and acoustic measures. In general, crispness was more related to force than to acoustic measures. Force linear distance and maximum force as measured by the mechanical-acoustic test were best correlated with sensory crispness and change in crispness, respectively. The correlations varied by apple genotype. The best multiple linear regression model to predict change in sensory crispness between harvest and storage of fruit of this breeding family incorporated both force and acoustic measures. This work compared the abilities of instrumental tests to predict sensory crispness maintenance of apple fruit. The use of an instrumental method that is highly correlated to sensory crispness evaluation can enhance the efficiency and reduce the cost of measuring crispness for breeding purposes. This study showed that sensory crispness and change in crispness after storage of an apple breeding family were reliably predicted with a combination of instrumental measurements and multiple variable analyses. The strategy potentially can be applied to other apple varieties for more accurate interpretation of crispness maintenance measured instrumentally. © 2018 Wiley Periodicals, Inc.
Vrijhoef, Hubertus J. M.; Berbee, Rieneke; Wagner, Edward H.; Steuten, Lotte M. G.
2009-01-01
Abstract Objective To identify the most appropriate generic instrument to measure experience and/or satisfaction of people receiving integrated chronic care. Background Health care is becoming more user‐centred and, as a result, the experience of users of care and evaluation of their experience and/or satisfaction is taken more seriously. It is unclear to what extent existing instruments are appropriate in measuring the experience and/or satisfaction of people using integrated chronic care. Methods Instruments were identified by means of a systematic literature review. Appropriateness of instruments was analysed on seven criteria. The two most promising instruments were translated into Dutch, if necessary, and administered to a convenience sample of 109 people with a chronic illness. Data derived from respondents were analysed statistically. Focus‐group interviews were conducted to assess the semantic and technical equivalence as well as opinions of people about the applicability and relevance of the translated instruments. Results From 37 instruments identified, the Patients’ Assessment of Care for chronIc Conditions (PACIC) and the short form of the Patient Satisfaction Questionnaire III (PSQ‐18) were selected as most promising instruments. Both instruments produced similar median scores across people with different chronic conditions. The overall PACIC and its subscales and the overall PSQ‐18 were highly internally consistent, but not the PSQ‐18 subscales. Overall, the PACIC demonstrated better psychometric characteristics. PACIC and PSQ‐18 scores were found to be moderately correlated. Whereas more respondents preferred the PSQ‐18, focus‐group participants regarded the PACIC to be more applicable and relevant. The technical and semantic equivalence of both instruments were sufficient. Conclusions Because of its psychometric characteristics, perceived applicability and relevance, the PACIC is the most appropriate instrument to measure the experience of people receiving integrated chronic care. PMID:19709315
Nilvér, Helena; Begley, Cecily; Berg, Marie
2017-06-29
Women's childbirth experience can have immediate as well as long-term positive or negative effects on their life, well-being and health. When evaluating and drawing conclusions from research results, women's experiences of childbirth should be one aspect to consider. Researchers and clinicians need help in finding and selecting the most suitable instrument for their purpose. The aim of this study was therefore to systematically identify and present validated instruments measuring women's childbirth experience. A systematic review was conducted in January 2016 with a comprehensive search in the bibliographic databases PubMed, CINAHL, Scopus, The Cochrane Library and PsycINFO. Included instruments measured women's childbirth experiences. Papers were assessed independently by two reviewers for inclusion, and quality assessment of included instruments was made by two reviewers independently and in pairs using Terwee et al's criteria for evaluation of psychometric properties. In total 5189 citations were screened, of which 5106 were excluded by title and abstract. Eighty-three full-text papers were reviewed, and 37 papers were excluded, resulting in 46 included papers representing 36 instruments. These instruments demonstrated a wide range in purpose and content as well as in the quality of psychometric properties. This systematic review provides an overview of existing instruments measuring women's childbirth experiences and can support researchers to identify appropriate instruments to be used, and maybe adapted, in their specific contexts and research purpose.
Process Skill Assessment Instrument: Innovation to measure student’s learning result holistically
NASA Astrophysics Data System (ADS)
Azizah, K. N.; Ibrahim, M.; Widodo, W.
2018-01-01
Science process skills (SPS) are very important skills for students. However, the fact that SPS is not being main concern in the primary school learning is undeniable. This research aimed to develop a valid, practical, and effective assessment instrument to measure student’s SPS. Assessment instruments comprise of worksheet and test. This development research used one group pre-test post-test design. Data were obtained with validation, observation, and test method to investigate validity, practicality, and the effectivenss of the instruments. Results showed that the validity of assessment instruments is very valid, the reliability is categorized as reliable, student SPS activities have a high percentage, and there is significant improvement on student’s SPS score. It can be concluded that assessment instruments of SPS are valid, practical, and effective to be used to measure student’s SPS result.
Lewis, Cara C; Fischer, Sarah; Weiner, Bryan J; Stanick, Cameo; Kim, Mimi; Martinez, Ruben G
2015-11-04
High-quality measurement is critical to advancing knowledge in any field. New fields, such as implementation science, are often beset with measurement gaps and poor quality instruments, a weakness that can be more easily addressed in light of systematic review findings. Although several reviews of quantitative instruments used in implementation science have been published, no studies have focused on instruments that measure implementation outcomes. Proctor and colleagues established a core set of implementation outcomes including: acceptability, adoption, appropriateness, cost, feasibility, fidelity, penetration, sustainability (Adm Policy Ment Health Ment Health Serv Res 36:24-34, 2009). The Society for Implementation Research Collaboration (SIRC) Instrument Review Project employed an enhanced systematic review methodology (Implement Sci 2: 2015) to identify quantitative instruments of implementation outcomes relevant to mental or behavioral health settings. Full details of the enhanced systematic review methodology are available (Implement Sci 2: 2015). To increase the feasibility of the review, and consistent with the scope of SIRC, only instruments that were applicable to mental or behavioral health were included. The review, synthesis, and evaluation included the following: (1) a search protocol for the literature review of constructs; (2) the literature review of instruments using Web of Science and PsycINFO; and (3) data extraction and instrument quality ratings to inform knowledge synthesis. Our evidence-based assessment rating criteria quantified fundamental psychometric properties as well as a crude measure of usability. Two independent raters applied the evidence-based assessment rating criteria to each instrument to generate a quality profile. We identified 104 instruments across eight constructs, with nearly half (n = 50) assessing acceptability and 19 identified for adoption, with all other implementation outcomes revealing fewer than 10 instruments. Only one instrument demonstrated at least minimal evidence for psychometric strength on all six of the evidence-based assessment criteria. The majority of instruments had no information regarding responsiveness or predictive validity. Implementation outcomes instrumentation is underdeveloped with respect to both the sheer number of available instruments and the psychometric quality of existing instruments. Until psychometric strength is established, the field will struggle to identify which implementation strategies work best, for which organizations, and under what conditions.
47 CFR 2.1505 - Test instrumentation and equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Test instrumentation and equipment. 2.1505... Position Indicating Radiobeacons (EPIRBs) General § 2.1505 Test instrumentation and equipment. (a) Receiver... peak measurements with a bandwidth of 100 kHz. (b) Spectrum analyzer. Spectral measurements are to be...
Diode laser-based cavity ring-down instrument for NO3, N2O5, NO, NO2 and O3 from aircraft
NASA Astrophysics Data System (ADS)
Wagner, N. L.; Dubé, W. P.; Washenfelder, R. A.; Young, C. J.; Pollack, I. B.; Ryerson, T. B.; Brown, S. S.
2011-03-01
This article presents a diode laser based, cavity ring-down spectrometer for simultaneous in situ measurements of four nitrogen oxide species, NO3, N2O5, NO, NO2, as well as O3, designed for deployment on aircraft. The instrument measures NO3 and NO2 by optical extinction at 662 nm and 405 nm, respectively; N2O5 is measured by thermal conversion to NO3, while NO and O3 are measured by chemical conversion to NO2. The instrument has several advantages over previous instruments developed by our group for measurement of NO2, NO3 and N2O5 alone, based on a pulsed Nd:YAG and dye laser. First, the use of continuous wave diode lasers reduces the requirements for power and weight and eliminates hazardous materials. Second, detection of NO2 at 405 nm is more sensitive than our previously reported 532 nm instrument, and does not have a measurable interference from O3. Third, the instrument includes chemical conversion of NO and O3 to NO2 to provide measurements of total NOx (= NO + NO2) and Ox (= NO2 + O3) on two separate channels; mixing ratios of NO and O3 are determined by subtraction of NO2. Finally, all five species are calibrated against a single standard based on 254 nm O3 absorption to provide high accuracy. Disadvantages include an increased sensitivity to water vapor on the 662 nm NO3 and N2O5 channels and a modest reduction in sensitivity for these species compared to the pulsed laser instrument. The measurement precision for both NO3 and N2O5 is below 1 pptv (2σ, 1 s) and for NO, NO2 and O3 is 170, 46, and 56 pptv (2σ, 1 s) respectively. The NO and NO2 measurements are less precise than research-grade chemiluminescence instruments. However, the combination of these five species in a single instrument, calibrated to a single analytical standard, provides a complete and accurate picture of nighttime nitrogen oxide chemistry. The instrument performance is demonstrated using data acquired during a recent field campaign in California.
NASA Astrophysics Data System (ADS)
Borovski, A.; Postylyakov, O.; Elokhov, A.; Bruchkovski, I.
2017-11-01
An instrument for measuring atmospheric trace gases by DOAS method using scattered solar radiation was developed in A.M.Obukhov IAP RAS. The instrument layout is based on the lab Shamrock 303i spectrograph supplemented by 2-port radiation input system employing optical fiber. Optical ports may be used with a telescope with fixed field of view or with a scanning MAX-DOAS unit. MAX-DOAS unit port will be used for investigation of gas contents and profiles in the low troposphere. In September 2016 the IAP instrument participated in the CINDI-2 campaign, held in the Netherlands. CINDI 2 (2nd Cabauw Intercomparison of Nitrogen Dioxide Measuring Instruments) involves about 40 instruments quasi-synchronously performing DOAS measurements of NO2 and other trace gases. During the campaign the instrument ports had telescopes A and B with similar field of view of about 0.3°. Telescope A was always directed to the zenith. Telescope B was directed at 5° elevation angle. Two gratings were installed in the spectrometer. They provide different spectral resolution (FWHM 0.4 and 0.8 nm respectively) and spectral window width ( 70 and 140 nm respectively). During CINDI-2 campaign we performed test measurements in UV and visible wavelength ranges to investigate instrument stability and retrieval errors of NO2 and HCHO contents. We perform the preliminary error analysis of retrieval of the NO2 and HCHO differential slant column densities using spectra measured in four modes of the instrument basing on residual noise analysis in this paper. It was found that rotation of grating turret does not significantly affected on quality of NO2 DSCD retrieval from spectra which measured in visible spectral region. Influence of grating turret rotation is much more significant for gas DSCD retrieval from spectra which measured in UV spectral region. Standard deviation of retrieval error points to presence of some systematic error.
Savage, Michael J.
2010-01-01
The possibility of reliable, reasonably accurate and relatively inexpensive estimates of sensible heat and latent energy fluxes was investigated using a commercial combination thin-film polymer capacitive relative humidity and adjacent temperature sensor instrument. Long-term and unattended water vapour pressure profile difference measurements using low-power combination instruments were compared with those from a cooled dewpoint mirror hygrometer, the latter often used with Bowen ratio energy balance (BREB) systems. An error analysis, based on instrument relative humidity and temperature errors, was applied for various capacitive humidity instrument models. The main disadvantage of a combination capacitive humidity instrument is that two measurements, relative humidity and temperature, are required for estimation of water vapour pressure as opposed to one for a dewpoint hygrometer. In a laboratory experiment using an automated procedure, water vapour pressure differences generated using a reference dewpoint generator were measured using a commercial model (Dew-10) dewpoint hygrometer and a combination capacitive humidity instrument. The laboratory measurement comparisons showed that, potentially, an inexpensive model combination capacitive humidity instrument (CS500 or HMP50), or for improved results a slightly more expensive model (HMP35C or HMP45C), could substitute for the more expensive dewpoint hygrometer. In a field study, in a mesic grassland, the water vapour pressure measurement noise for the combination capacitive humidity instruments was greater than that for the dewpoint hygrometer. The average water vapour pressure profile difference measured using a HMP45C was highly correlated with that from a dewpoint hygrometer with a slope less than unity. Water vapour pressure measurements using the capacitive humidity instruments were not as accurate, compared to those obtained using a dewpoint hygrometer, but the resolution magnitudes for the profile difference measurements were less than the minimum of 0.01 kPa required for BREB measurements when averaged over 20 min. Furthermore, the longer-term capacitive humidity measurements are more reliable and not dependent on a sensor bias adjustment as is the case for the dewpoint hygrometer. A field comparison of CS500 and HMP45C profile water vapour pressure differences yielded a slope of close to unity. However, the CS500 exhibited more variable water vapour pressure measurements mainly due to its increased variation in temperature measurements compared to the HMP45C. Comparisons between 20-min BREB sensible heat fluxes obtained using a HMP45C and a dewpoint hygrometer yielded a slope of almost unity. BREB sensible heat fluxes measured using a HMP45C were reasonably well correlated with those obtained using a surface-layer scintillometer and eddy covariance (slope of 0.9629 and 0.9198 respectively). This reasonable agreement showed that a combination capacitive humidity instrument, with similar relative humidity (RH) and temperature error magnitudes of at most 2% RH and 0.3 °C respectively, and similar measurement time response, would be an adequate and less expensive substitute for a dewpoint hygrometer. Furthermore, a combination capacitive humidity instrument requires no servicing compared to a dewpoint hygrometer which requires a bias adjustment and mirror cleaning each week. These findings make unattended BREB measurements of sensible heat flux and evaporation cheaper and more reliable with the system easier to assemble and service and with reduced instrument power. PMID:22163625
NASA Astrophysics Data System (ADS)
Silverman, M. L.; Chen, G.; Shook, M.
2016-12-01
Airborne field campaigns have long understood the importance of well-defined measurement uncertainties and their impact on scientific research. Measurement comparisons are an effective way to assess the uncertainty of different techniques as well as gain insight into instrument performance. As part of the NASA DC3 (Deep Convective Clouds and Chemistry) airborne field campaign, there were several wing-tip-to-wing-tip formation flight segments designed for measurement comparison of the instruments onboard the NASA DC-8 and NSF/NCAR Gulfstream-V aircraft. This provides the opportunity to evaluate the consistency between multiple measurements of the same species/parameters on different platforms and based on different measurement techniques. The DC-8 aircraft was also instrumented with duplicate measurements of the same species, allowing for intraplatform comparisons. The NASA DC-8 was also used during the NASA SEAC4RS (Studies of Emission and Atmospheric Composition, Clouds, and Climate Coupling by Regional Surveys) airborne field campaign. While no wing-tip to wing-tip flights were flown, several instruments measuring the same species were aboard the DC-8 providing intraplatform comparisons. Time series and correlations are produced to show the relative agreement between the measurements both on a daily basis and over the course of the five inter-comparison days. We have also used a data-driven approach to analyze the instrument precisions as an important part of measurement uncertainty assessment. By conducting these analyses we provide insight to users on the quality of the measurements.
NASA Technical Reports Server (NTRS)
Hoegger, Bruno; Viatte, Pierre; Levrat, Gilbert; Bader, Juerg; Ribordy, Pascale; Schill, Herbert; Staehelin, Johannes
1994-01-01
Total ozone observations of two Dobson instruments (D15 and D101, C- and AD wavelength pair observations) and of two Brewer instruments (Br40 and Br72) are currently performed at the LKO at Arosa. A quality control concept is presented in order to make best use of the large number of quasi-simultaneous measurements. The longest ozone series of the world is mainly based on the measurements of the Dobson instrument D15 (wavelength pair C). Since the last years D15 has suffered from instrumental problems. The transformation of the longterm series to the measurements of D101(AD) is described.
Correlative measurement opportunities between ATLAS-1 and UARS experiments
NASA Technical Reports Server (NTRS)
Harrison, Edwin F.; Denn, Fred M.; Gibson, Gary G.
1992-01-01
The first ATmospheric Laboratory for Applications and Science (ATLAS-1) mission was flown aboard the Space Shuttle from March 24 to April 2, 1992. The ATLAS-1 instruments provided a large number of measurements which were coincident with observations from experiments on the Upper Atmosphere Research Satellite (UARS). During the ATLAS-1 mission, simulations were performed to predict when and where coincident measurements between ATLAS and UARS instruments would occur. These predictions were used to develop instrument operation schedules to maximize the correlative opportunities between the two satellites. Results of the simulations provide valuable information for the ATLAS and UARS scientists to compare measurements between various instruments on the two satellites.
Proceedings of a Workshop on Assessment of Techniques for Measuring Tropospheric N sub x O sub y
NASA Technical Reports Server (NTRS)
1983-01-01
Human impact on the troposphere, particularly on the regional to global scale is assessed. One area of required research is instrumentation development, which is aimed at improving the capability to measure important trace gases and aerosols which are key species in the major atmospheric biogeochemical cycles. To focus on specific needs, the Instrumentation Workshop for NxOy Tropospheric Species was conducted. The workshop discussed measurement needs and instrument capabilities for NxOy species, including NO, NO2, HNO3, HNO2, PAN, and NO3 aerosols. The status and measurement capabilities of various techniques (operational as well as conceptual) were discussed, along with future instrument and technology needs.
JAERI instrumented spool piece performance in two-phase flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colson, J.B.; Gilbert, J.V.
1979-01-01
Instrumented spool pieces to be installed in horizontal piping on the Cylindrical Core Test Facility (CCTF) at the Japanese Atomic Energy Institute (JAERI) have been designed and tested. The instrumented spool pieces will provide measurements from which mass flow rates can be computed. The primary instruments included in the spool pieces are a full-flow turbine, a full-flow perforated drag plate, and a low energy three-beam photon densitometer. Secondary instruments are provided to measured absolute pressure, fluid temperature, and differential pressure across the full-flow perforated drag plate.
Development of assessment instruments to measure critical thinking skills
NASA Astrophysics Data System (ADS)
Sumarni, W.; Supardi, K. I.; Widiarti, N.
2018-04-01
Assessment instruments that is commonly used in the school generally have not been orientated on critical thinking skills. The purpose of this research is to develop assessment instruments to measure critical thinking skills, to test validity, reliability, and practicality. This type of research is Research and Development. There are two stages on the preface step, which are field study and literacy study. On the development steps, there some parts, which are 1) instrument construction, 2) expert validity, 3) limited scale tryout and 4) narrow scale try-out. The developed assessment instrument are analysis essay and problem solving. Instruments were declared valid, reliable and practical.
Lester, L; Bulsara, C; Petterson, A; Bennett, K; Allen, E; Joske, D
2017-01-01
Objectives The Patient Evaluation of Emotional Comfort Experienced (PEECE) is a 12-item questionnaire which measures the mental well-being state of emotional comfort in patients. The instrument was developed using previous qualitative work and published literature. Design Instrument development. Setting Acute Care Public Hospital, Western Australia. Participants Sample of 374 patients. Interventions A multidisciplinary expert panel assessed the face and content validity of the instrument and following a pilot study, the psychometric properties of the instrument were explored. Main outcome measures Exploratory and confirmatory factor analysis assessed the underlying dimensions of the PEECE instrument; Cronbach's α was used to determine the reliability; κ was used for test–retest reliability of the ordinal items. Results 2 factors were identified in the instrument and named ‘positive emotions’ and ‘perceived meaning’. A greater proportion of male patients were found to report positive emotions compared with female patients. The instrument was found to be feasible, reliable and valid for use with inpatients and outpatients. Conclusions PEECE was found to be a feasible instrument for use with inpatient and outpatients, being easily understood and completed. Further psychometric testing is recommended. PMID:28122833
High-speed noncontacting instrumentation for jet engine testing
NASA Astrophysics Data System (ADS)
Scotto, M. J.; Eismeier, M. E.
1980-03-01
This paper discusses high-speed, noncontacting instrumentation systems for measuring the operating characteristics of jet engines. The discussion includes optical pyrometers for measuring blade surface temperatures, capacitance clearanceometers for measuring blade tip clearance and vibration, and optoelectronic systems for measuring blade flex and torsion. In addition, engine characteristics that mandate the use of such unique instrumentation are pointed out as well as the shortcomings of conventional noncontacting devices. Experimental data taken during engine testing are presented and recommendations for future development discussed.
NASA Technical Reports Server (NTRS)
1990-01-01
Evaluations are summarized directed towards defining optimal instrumentation for performing planetary polarization measurements from a spacecraft platform. An overview of the science rationale for polarimetric measurements is given to point out the importance of such measurements for future studies and exploration of the outer planets. The key instrument features required to perform the needed measurements are discussed and applied to the requirements for the Cassini mission to Saturn. The resultant conceptual design of a spectro-polarimeter photometer for Cassini is described in detail.
Generally objective measurement of human temperature and reading ability: some corollaries.
Stenner, A Jackson; Stone, Mark
2010-01-01
We argue that a goal of measurement is general objectivity: point estimates of a person's measure (height, temperature, and reader ability) should be independent of the instrument and independent of the sample in which the person happens to find herself. In contrast, Rasch's concept of specific objectivity requires only differences (i.e., comparisons) between person measures to be independent of the instrument. We present a canonical case in which there is no overlap between instruments and persons: each person is measured by a unique instrument. We then show what is required to estimate measures in this degenerate case. The canonical case encourages a simplification and reconceptualization of validity and reliability. Not surprisingly, this reconceptualization looks a lot like the way physicists and chemometricians think about validity and measurement error. We animate this presentation with a technology that blurs the distinction between instruction, assessment, and generally objective measurement of reader ability. We encourage adaptation of this model to health outcomes measurement.
Instruments and Scoring Guide of the Experiential Education Evaluation Project.
ERIC Educational Resources Information Center
Conrad, Dan; Hedin, Diane
As a result of the Experiential Education Evaluation Project the publication identifies instruments used to measure and assess experiential learning programs. The following information is given for each instrument: rationale for its inclusion in the study; precise issues or outcomes designed to measure, validity and reliability data; and…
Instruments Assessing Anxiety in Adults with Intellectual Disabilities: A Systematic Review
ERIC Educational Resources Information Center
Hermans, Heidi; van der Pas, Femke H.; Evenhuis, Heleen M.
2011-01-01
Background: In the last decades several instruments measuring anxiety in adults with intellectual disabilities have been developed. Aim: To give an overview of the characteristics and psychometric properties of self-report and informant-report instruments measuring anxiety in this group. Method: Systematic review of the literature. Results:…
Computer-Aided Instruction in Automated Instrumentation.
ERIC Educational Resources Information Center
Stephenson, David T.
1986-01-01
Discusses functions of automated instrumentation systems, i.e., systems which combine electrical measuring instruments and a controlling computer to measure responses of a unit under test. The computer-assisted tutorial then described is programmed for use on such a system--a modern microwave spectrum analyzer--to introduce engineering students to…
The Development of an Instrument to Measure Creative Teaching Abilities.
ERIC Educational Resources Information Center
Riley, John F.
The development of an instrument to measure creative teaching abilities, the Creative Teaching Dilemma (CTD), involved three phases. The instrument was constructed and refined, and scoring procedures were outlined. The activities comprising the CTD included defining the teaching dilemma, gathering additional facts, identifying and stating the…
Trace Gas Retrievals from the GeoTASO Aircraft Instrument During the DISCOVER-AQ Campaigns
NASA Astrophysics Data System (ADS)
Nowlan, C. R.; Liu, X.; Leitch, J. W.; Liu, C.; Gonzalez Abad, G.; Chance, K.; Delker, T.; Good, W. S.; Murcray, F.; Ruppert, L.; Kaptchen, P. F.; Loughner, C.; Follette-Cook, M. B.; Pickering, K. E.
2014-12-01
The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument is a recently-developed passive remote sensing instrument capable of making 2-D measurements of trace gases from aircraft. GeoTASO was developed under NASA's Instrument Incubator program and is a test-bed instrument for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey and the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) satellite missions. The instrument collects spectra of backscattered UV-visible radiation for the detection of tropospheric trace gases such as NO2, ozone, formaldehyde and SO2. GeoTASO flew on the NASA HU-25C Falcon aircraft during the 2013 (Texas) and 2014 (Colorado) DISCOVER-AQ field campaigns, making satellite-analog measurements of trace gases at a spatial resolution of approximately 500x500 m over urban areas, power plants and other industrial sources of pollution. We present the GeoTASO retrieval algorithms, trace gas measurement results, and validation comparisons with ground-based observations and other aircraft instruments during these campaigns.
Kirwan, John R; Fries, James F; Hewlett, Sarah E; Osborne, Richard H; Newman, Stanton; Ciciriello, Sabina; van de Laar, Mart A; Dures, Emma; Minnock, Patricia; Heiberg, Turid; Sanderson, Tessa C; Flurey, Caroline A; Leong, Amy L; Montie, Pamela; Richards, Pam
2011-08-01
The workshop Choosing or Developing Instruments held at the Outcome Measures in Rheumatology (OMERACT) 10 meeting was designed to help participants think about the underlying methods of instrument development. Conference pre-reading material and 3 brief introductory presentations elaborated the issues, and participants broke into discussion groups before reconvening to share insights, engage in a more general discussion of the issues, and vote on recommendations. Tradeoffs between using current imperfect measures and the long and complex process of developing new instruments were considered, together with the need for rigor in patient-reported outcome (PRO) instrument development. The main considerations for PRO instrument development were listed and a research agenda for action produced. As part of the agenda for action, it is recommended that researchers and patient partners work together to tackle these issues, and that OMERACT bring forward proposals for acceptable instrument development protocols that would meet an enhanced "Truth" statement in the OMERACT Filter.
NASA Technical Reports Server (NTRS)
Chyba, Thomas; Zenker, Thomas
1998-01-01
The objective of this project is to develop a portable, eye-safe, ground-based ozone lidar instrument specialized for ozone differential absorption lidar (DIAL) measurements in the troposphere. This prototype instrument is intended to operate at remote field sites and to serve as the basic unit for monitoring projects requiring multi-instrument networks, such as that discussed in the science plan for the Global Tropospheric Ozone Project (GTOP). This instrument will be based at HU for student training in lidar technology as well as atmospheric ozone data analysis and interpretation. It will be also available for off-site measurement campaigns and will serve as a test bed for further instrument development. Later development beyond this grant to extend the scientific usefulness of the instrument may include incorporation of an aerosol channel and upgrading the laser to make stratospheric ozone measurements. Undergraduate and graduate students have been and will be active participants in this research effort.
Reliability and Validity of the Turkish Version of the Job Performance Scale Instrument.
Harmanci Seren, Arzu Kader; Tuna, Rujnan; Eskin Bacaksiz, Feride
2018-02-01
Objective measurement of the job performance of nursing staff using valid and reliable instruments is important in the evaluation of healthcare quality. A current, valid, and reliable instrument that specifically measures the performance of nurses is required for this purpose. The aim of this study was to determine the validity and reliability of the Turkish version of the Job Performance Instrument. This study used a methodological design and a sample of 240 nurses working at different units in four hospitals in Istanbul, Turkey. A descriptive data form, the Job Performance Scale, and the Employee Performance Scale were used to collect data. Data were analyzed using IBM SPSS Statistics Version 21.0 and LISREL Version 8.51. On the basis of the data analysis, the instrument was revised. Some items were deleted, and subscales were combined. The Turkish version of the Job Performance Instrument was determined to be valid and reliable to measure the performance of nurses. The instrument is suitable for evaluating current nursing roles.
NASA Astrophysics Data System (ADS)
Pitt, Joseph; Young, Stuart; Hopkins, James; Lee, James; Bauguitte, Stéphane; Dorsey, James; Allen, Grant; Gallagher, Martin; Yacovitch, Tara; Zahniser, Mark; Fisher, Rebecca; Lowry, Dave; Nisbet, Euan
2017-04-01
We describe the configuration of two commercially available absorption spectrometers for use on board the UK Facility for Airborne Atmospheric Research (FAAM) aircraft. A dual laser instrument has been used to make continuous measurements of the atmospheric 13CH4:12CH4 ratio and ethane mole fraction, using an interband cascade laser (ICL) and a recently developed type of diode laser respectively. Simultaneous measurements of atmospheric ethane have also been made using a single laser instrument employing an ICL, enabling instrument inter-comparison. Instrument performance is evaluated over a series of test flights, and initial results from the MOYA (Methane Observations and Yearly Assessments) campaign, targeting biomass burning plumes in west Africa, are also presented. We describe the calibration procedure and data analysis approaches for methane isotope measurement, involving calibration over a range of methane isotopic composition and methane mole fraction. We assess the effectiveness of this calibration technique during the first MOYA campaign period using measurements of a target cylinder of known composition.
Bookey-Bassett, Sue; Markle-Reid, Maureen; McKey, Colleen; Akhtar-Danesh, Noori
2016-01-01
It is acknowledged internationally that chronic disease management (CDM) for community-living older adults (CLOA) is an increasingly complex process. CDM for older adults, who are often living with multiple chronic conditions, requires coordination of various health and social services. Coordination is enabled through interprofessional collaboration (IPC) among individual providers, community organizations, and health sectors. Measuring IPC is complicated given there are multiple conceptualisations and measures of IPC. A literature review of several healthcare, psychological, and social science electronic databases was conducted to locate instruments that measure IPC at the team level and have published evidence of their reliability and validity. Five instruments met the criteria and were critically reviewed to determine their strengths and limitations as they relate to CDM for CLOA. A comparison of the characteristics, psychometric properties, and overall concordance of each instrument with salient attributes of IPC found the Collaborative Practice Assessment Tool to be the most appropriate instrument for measuring IPC for CDM in CLOA.
NASA Technical Reports Server (NTRS)
Wu, Yen-Hung; Key, Richard; Sander, Stanley; Blavier, Jean-Francois; Rider, David
2011-01-01
This paper summarizes the design and development of the Panchromatic Imaging Fourier Transform Spectrometer (PanFTS) for the NASA Geostationary Coastal and Air Pollution Events (GEO-CAPE) Mission. The PanFTS instrument will advance the understanding of the global climate and atmospheric chemistry by measuring spectrally resolved outgoing thermal and reflected solar radiation. With continuous spectral coverage from the near-ultraviolet through the thermal infrared, this instrument is designed to measure pollutants, greenhouse gases, and aerosols as called for by the U.S. National Research Council Decadal Survey; Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond1. The PanFTS instrument is a hybrid instrument based on spectrometers like the Tropospheric Emissions Spectrometer (TES) that measures thermal emission, and those like the Orbiting Carbon Observatory (OCO), and the Ozone Monitoring Instrument (OMI) that measure scattered solar radiation. Simultaneous measurements over the broad spectral range from IR to UV is accomplished by a two sided interferometer with separate optical trains and detectors for the ultraviolet-visible and infrared spectral domains. This allows each side of the instrument to be independently optimized for its respective spectral domain. The overall interferometer design is compact because the two sides share a single high precision cryogenic optical path difference mechanism (OPDM) and metrology laser as well as a number of other instrument systems including the line-of-sight pointing mirror, the data management system, thermal control system, electrical system, and the mechanical structure. The PanFTS breadboard instrument has been tested in the laboratory and demonstrated the basic functionality for simultaneous measurements in the visible and infrared. It is set to begin operations in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson measuring the atmospheric chemistry across the Los Angeles basin. Development has begun on a flight size PanFTS engineering model (EM) that addresses all critical scaling issues and demonstrates operation over the full spectral range of the flight instrument which will show the PanFTS instrument design is mature.
Measures of Wellness in Young Adult College Students: An Integrative Review.
Nair, Julie McCulloh
2018-04-01
Wellness behaviors typically form during the college years, making wellness evaluation crucial during this time frame. Instruments often assess health rather than wellness. Thus, the purpose of this integrative review is to identify and evaluate instruments measuring wellness among young adult college students. Google Scholar, CINAHL, PubMed, MEDLINE, PsycINFO, ERIC, and other databases were searched yielding 350 studies initially. Seven studies met inclusion criteria and were retained for this review. Reliability and validity is reported in each study with ongoing analysis. Homogeneous samples were reported in each study, and administering concurrent instruments created feasibility issues. A summary of instruments measuring wellness in young adult college students is provided. However, few wellness instruments exist in this population. Thus, further development is needed.
Application of low-power, high-rate PCM telemetry in a helicopter instrumentation system
NASA Technical Reports Server (NTRS)
Thomas, Mitchel E.; Diamond, John K.
1987-01-01
The use of low-power, high-rate pulse code modulation (PCM) in a helicopter instrumentation system is examined. A Helicopter Instrumentation and Recording System (HIARS) was developed to obtain main rotor blade measurements and fuselage performance measurements. The HIARS consists of a low-power PCM telemeter, a digital PCM system, an optical rotor position sensor, and a PCM decommutation unit; the components and functions of these subsystems are described. Flight tests were conducted to evaluate the ability of the HIARS to measure aircraft parameters. The test data reveal that the PCM telemetry is applicable to helicopter instrumentation systems.
A photophonic instrument concept to measure atmospheric aerosol absorption. M.S. Thesis
NASA Technical Reports Server (NTRS)
Engle, C. D.
1982-01-01
A laboratory model of an instrument to measure the absorption of atmospheric aerosols was designed, built, and tested. The design was based on the photophonic phenomenon discovered by Bell and an acoustic resonator developed by Helmholtz. Experiments were done to show ways the signal amplitude could be improved and the noise reduced and to confirm the instrument was sensitive enough to be practical. The research was undertaken to develop concepts which show promise of being improvements on the instruments that are presently used to measure the absorption of the Sun's radiation by the Earth's atmospheric aerosols.
Albarracín, Dolores; Wilson, Kristina; Durantini, Marta R.; Sunderrajan, Aashna; Livingood, William
2016-01-01
Objective A randomized control trial with 722 eligible clients from a health department in the State of Florida was conducted to identify a simple, effective meta-intervention to increase completion of an HIV-prevention counseling program. Method The overall design involved two factors representing an empowering and instrumental message, as well as an additional factor indicating presence or absence of expectations about the counseling. Completion of the three-session counseling was determined by recording attendance. Results A logistic regression analysis with the three factors of empowering message, instrumental message, and presence of mediator measures, as well as all interactions, revealed significant interactions between instrumental and empowering messages and between instrumental messages and presence of mediator measures. Results indicated that (a) the instrumental message alone produced most completion than any other message, and (b) when mediators were not measured, including the instrumental message led to greater completion. Conclusions The overall gains in completion as a result of the instrumental message were 16%, implying success in the intended facilitation of counseling completion. The measures of mediators did not detect any experimental effects, probably because the effects were happening without much conscious awareness. PMID:27786499
[Engine-driven preparation of curved root canals: a platform to assess physical parameters].
Peters, O A; Kappeler, S; Bucher, W; Barbakow, F
2001-01-01
The number of engine-driven rotary instruments available on the market is steadily increasing. These instruments enable clinicians to prepare better shaped root canals, however, rotary instruments have a higher risk for fracture than hand instruments. Unfortunately, the stresses placed on engine-driven rotary instruments in curved canals are insufficiently studied. The aim of this study was to develop a device which could measure more accurately the physical parameters influencing rotary instruments in curved canals. For this purpose, a specially designed machine was constructed to measure the torque which develops between the rotary instrument and the motor. Apical forces and penetration depths could also be directly measured in real time. A variety of other measurements was also possible because of other special set-ups integrated into the device. In the current study torque was assessed for GT-Files, size 35 with a .12 and sizes 20 with a .12 to .06 taper. In additions to preparations in simulated canals in plastic blocks, the "ISO 3630-1 specification for fracture moment" and "number of cycles till fatigue fracture" was measured. The findings indicated that when instruments were used for preparations, torques up to 40 Nmm were present. This exceeded the static fracture load, which was less than than 13 Nmm for the size 20 with .12 taper. In contrast, the number of rotations were more than 10 times lower when shaping canals in plastic blocks with a 5 mm radius of curvature than the number of rotations to fracture in the "cyclic fatigue test". This suggests that a GT-instrument could be used in ten canals. The apical force was always greater than 1 N and occasionally, 8 N or more was recorded. Further studies on natural teeth with varying canal geometries are required using the specially developed torsional machine to reduce the incidence of instrument fracture. In this way an efficient clinical potential can be confirmed for engine-driven rotary instruments in canal preparation.
Measuring soot particles from automotive exhaust emissions
NASA Astrophysics Data System (ADS)
Andres, Hanspeter; Lüönd, Felix; Schlatter, Jürg; Auderset, Kevin; Jordan-Gerkens, Anke; Nowak, Andreas; Ebert, Volker; Buhr, Egbert; Klein, Tobias; Tuch, Thomas; Wiedensohler, Alfred; Mamakos, Athanasios; Riccobono, Francesco; Discher, Kai; Högström, Richard; Yli-Ojanperä, Jaakko; Quincey, Paul
2014-08-01
The European Metrology Research Programme participating countries and the European Union jointly fund a three year project to address the need of the automotive industry for a metrological sound base for exhaust measurements. The collaborative work on particle emissions involves five European National Metrology Institutes, the Tampere University of Technology, the Joint Research Centre for Energy and Transport and the Leibniz Institute for Tropospheric Research. On one hand, a particle number and size standard for soot particles is aimed for. Eventually this will allow the partners to provide accurate and comparable calibrations of measurement instruments for the type approval of Euro 5b and Euro 6 vehicles. Calibration aerosols of combustion particles, silver and graphite proof partially suitable. Yet, a consensus choice together with instrument manufactures is pending as the aerosol choice considerably affects the number concentration measurement. Furthermore, the consortium issued consistent requirements for novel measuring instruments foreseen to replace today's opacimeters in regulatory periodic emission controls of soot and compared them with European legislative requirements. Four partners are conducting a metrological validation of prototype measurement instruments. The novel instruments base on light scattering, electrical, ionisation chamber and diffusion charging sensors and will be tested at low and high particle concentrations. Results shall allow manufacturers to further improve their instruments to comply with legal requirements.
NASA Astrophysics Data System (ADS)
Hammerschmidt, Ulf; Hameury, Jacques; Strnad, Radek; Turzó-Andras, Emese; Wu, Jiyu
2015-07-01
This paper presents a critical review of current industrial techniques and instruments to measure the thermal conductivity of thermal insulation materials, especially those insulations that can operate at temperatures above and up to . These materials generally are of a porous nature. The measuring instruments dealt with here are selected based on their maximum working temperature that should be higher than at least . These instruments are special types of the guarded hot-plate apparatus, the guarded heat-flow meter, the transient hot-wire and hot-plane instruments as well as the laser/xenon flash devices. All technical characteristics listed are quoted from the generally accessible information of the relevant manufacturers. The paper includes rankings of the instruments according to their standard retail price, the maximum sample size, and maximum working temperature, as well as the minimum in their measurement range.
International Instrumentation Symposium, 39th, Albuquerque, NM, May 2-6, 1993, Proceedings
NASA Astrophysics Data System (ADS)
Various papers on instrumentation are presented. The general topics addressed include: data acquisition and processing, wind tunnels, pressure measurements, thermal measurements, force measurements, aerospace, metrology, flow measurements, real-time systems, measurement uncertainty, data analysis and calibration, computer applications, special tests, reentry vehicle systems, and human engineering.
MOPITT - A gas correlation spectrometer for tropospheric Earth observations
NASA Technical Reports Server (NTRS)
Drummond, James R.; Colley, R.; Dorey, J.; Hackett, J.
1993-01-01
MOPITT (Measurement of Pollution in the Troposphere) is an instrument that will fly on the EOS AM-1 Polar Orbiting Platform, to be launched in mid-1998. The instrument accurately measures the concentration of carbon monoxide (CO) and methane (CH4) gas in the troposphere, using novel and conventional gas correlation spectroscopy techniques. These techniques are used to measure both the column amount and the vertical profile of the two gases in the troposphere. The instrument is nadir viewing and has cross-track scanning ability. It measures upwelling IR radiation through the atmosphere in the 4.6-micron and 2.3-micron bands for CO detection, and 2.2-micron for CH4. The instrument performance is enhanced using Stirling cycle mechanical coolers to maintain the IR detectors at less than 100 K. MOPITT has a total of eight detector channels to measure the total column of atmospheric CH4 gas to a precision of 1 percent, and to measure CO profiles to a precision of 10 percent. The instrument is self-calibrating to ensure data validity using internal targets and an external cold space view.
Aircraft noise measurement instrumentation and techniques
DOT National Transportation Integrated Search
1996-08-01
This letter report describes aircraft noise measurement instrumentation to : be used in the field. It includes guidance on good field-measurement : practice, general rules-of-thumb, as well as references to appropriate : national and international st...
NASA Astrophysics Data System (ADS)
Petzold, A.; Perim de Faria, J.; Berg, M.; Bundke, U.; Freedman, A.
2015-12-01
Monitoring the direct impact of aerosol particles on climate requires the continuous measurement of aerosol optical parameters like the aerosol extinction coefficient on a regular basis. Remote sensing and ground-based networks are well in place (e.g., AERONET, ACTRIS), whereas the regular in situ measurement of vertical profiles of atmospheric aerosol optical properties remains still an important challenge in quantifying climate change. The European Research Infrastructure IAGOS (In-service Aircraft for a Global Observing System; www.iagos.org) responds to the increasing requests for long-term, routine in situ observational data by using commercial passenger aircraft as measurement platform. However, scientific instrumentation for the measurement of atmospheric constituents requires major modifications before being deployable aboard in-service passenger aircraft. Recently, a compact and robust family of optical instruments based on the cavity attenuated phase shift (CAPS) technique has become available for measuring aerosol light extinction. While this technique was successfully deployed for ground-based atmospheric measurements under various conditions, its suitability for operation aboard aircraft in the free and upper free troposphere still has to be demonstrated. In this work, the modifications of a CAPS PMex instrument for measuring aerosol light extinction on aircraft, the results from subsequent laboratory tests for evaluating the modified instrument prototype, and first results from a field deployment aboard a research aircraft will be covered. In laboratory studies, the instrument showed excellent agreement (deviation < 5%) with theoretical values calculated from Rayleigh scattering cross-sections, when operated on pressurized air and CO2 at ambient and low pressure (~200 hPa). For monodisperse and polydisperse aerosols, reference aerosol extinction coefficients were calculated from measured size distributions and agreed with the CAPS PMex instrument response within 10% deviation. During the field deployment, aerosol extinction coefficients and associated aerosol size distributions have been measured and will be presented as comparison studies between measured and calculated data.
Analysis of In Situ Thermal Ion Measurements from the MICA Sounding Rocket
NASA Astrophysics Data System (ADS)
Fernandes, P. A.; Lynch, K. A.; Zettergren, M. D.; Hampton, D. L.; Fisher, L. E.; Powell, S. P.
2014-12-01
The MICA sounding rocket launched on 19 Feb. 2012 into several discrete, localized arcs in the wake of a westward traveling surge. In situ and ground-based observations provide a measured response of the ionosphere to preflight and localized auroral drivers. Initial analysis of the in situ thermal ion data indicate possible measurement of an ion conic at low altitude (< 325 km). In the low-energy regime, the response of the instrument varies from the ideal because the measured thermal ion population is sensitive to the presence of the instrument. The plasma is accelerated in the frame of the instrument due to flows, ram, and acceleration through the sheath which forms around the spacecraft. The energies associated with these processes are large compared to the thermal energy. Correct interpretation of thermal plasma measurements requires accounting for all of these plasma processes and the non-ideal response of the instrument in the low-energy regime. This is an experimental and modeling project which involves thorough analysis of ionospheric thermal ion data from the MICA campaign. Analysis includes modeling and measuring the instrument response in the low-energy regime as well as accounting for the complex sheath formed around the instrument. This results in a forward model in which plasma parameters of the thermal plasma are propagated through the sheath and instrument models, resulting in an output which matches the in situ measurement. In the case of MICA, we are working toward answering the question of the initiating source processes that result, at higher altitudes, in well-developed conics and outflow on auroral field lines.
A New Electromagnetic Instrument for Thickness Gauging of Conductive Materials
NASA Technical Reports Server (NTRS)
Fulton, J. P.; Wincheski, B.; Nath, S.; Reilly, J.; Namkung, M.
1994-01-01
Eddy current techniques are widely used to measure the thickness of electrically conducting materials. The approach, however, requires an extensive set of calibration standards and can be quite time consuming to set up and perform. Recently, an electromagnetic sensor was developed which eliminates the need for impedance measurements. The ability to monitor the magnitude of a voltage output independent of the phase enables the use of extremely simple instrumentation. Using this new sensor a portable hand-held instrument was developed. The device makes single point measurements of the thickness of nonferromagnetic conductive materials. The technique utilized by this instrument requires calibration with two samples of known thicknesses that are representative of the upper and lower thickness values to be measured. The accuracy of the instrument depends upon the calibration range, with a larger range giving a larger error. The measured thicknesses are typically within 2-3% of the calibration range (the difference between the thin and thick sample) of their actual values. In this paper the design, operational and performance characteristics of the instrument along with a detailed description of the thickness gauging algorithm used in the device are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cottingham, Patrick, E-mail: pcotting@usc.edu; Morey, Jennifer R.; Institute for Quantum Matter, Department of Physics and Astronomy, Johns Hopkins University, 3400 N. Charles St., Baltimore, MD 21218
2016-10-15
We report instrumentation for photovoltage and photocurrent spectroscopy over a larger continuous range of wavelengths, temperatures, and applied magnetic fields than other instruments described in the literature: 350 nm≤λ≤1700 nm, 1.8 K≤T≤300 K, and B≤9 T. This instrument uses a modulated monochromated incoherent light source with total power<30 μW in combination with an LED in order to probe selected regions of non-linear responses while maintaining low temperatures and avoiding thermal artifacts. The instrument may also be used to measure a related property, the photomagnetoresistance. We demonstrate the importance of normalizing measured responses for variations in light power and describe amore » rigorous process for performing these normalizations. We discuss several circuits suited to measuring different types of samples and provide analysis for converting measured values into physically relevant properties. Uniform approaches to measurement of these photoproperties are essential for reliable quantitative comparisons between emerging new materials with energy applications. - Highlights: • A novel instrument for measuring photoconductivity and photocurrents of materials and devices. • Continuous parameter space: 350 nm≤λ≤1700, 1.8 K≤T≤300 K, and B≤9 T. • Methodology for treating non-linear responses and variable lamp intensity. • Mathematical detail for extracting properties of materials from measured values is provided.« less
International Instrumentation Symposium, 34th, Albuquerque, NM, May 2-6, 1988, Proceedings
NASA Astrophysics Data System (ADS)
Various papers on aerospace instrumentation are presented. The general topics addressed include: blast and shock, wind tunnel instrumentations and controls, digital/optical sensors, software design/development, special test facilities, fiber optic techniques, electro/fiber optical measurement systems, measurement uncertainty, real time systems, pressure. Also discussed are: flight test and avionics instrumentation, data acquisition techniques, computer applications, thermal force and displacement, science and government, modeling techniques, reentry vehicle testing, strain and pressure.
Omejec, Gregor; Podnar, Simon
2018-06-01
The aim of the study was to compare the utility of instrument-based assessment of peripheral nerve function with the neurologic examination in ulnar neuropathy at the elbow (UNE). We prospectively recruited consecutive patients with suspected UNE, performed a neurologic examination, and performed instrument-based measurements (muscle cross-sectional area by ultrasonography, muscle strength by dynamometry, and sensation using monofilaments). We found good correlations between clinical estimates and corresponding instrument-based measurements, with similar ability to diagnose UNE and predict UNE pathophysiology. Although instrument-based methods provide quantitative evaluation of peripheral nerve function, we did not find them to be more sensitive or specific in the diagnosis of UNE than the standard neurologic examination. Likewise, instrument-based methods were not better able to differentiate between groups of UNE patients with different pathophysiologies. Muscle Nerve 57: 951-957, 2018. © 2017 Wiley Periodicals, Inc.
Transcultural adaptation of the Breast Cancer Awareness Measure.
Al-Khasawneh, E M; Leocadio, M; Seshan, V; Siddiqui, S T; Khan, A N; Al-Manaseer, M M
2016-09-01
To overcome the lack of a validated and robust Arabic instrument to measure breast cancer awareness. Currently, there is no validated Arabic instrument for measuring breast cancer awareness levels. We adapted, translated and validated the Breast Cancer Awareness Measure developed by Cancer Research UK. The instrument was translated into Arabic and back-translated for validation. Validation and reliability tests were conducted using purposively sampled 972 Arab women older than 20 years, living in Oman. The adapted content was validated by a panel of medical, linguistic and cultural experts, followed by cognitive interviews (n = 10), behavioural coding (n = 30) and criterion validation (n = 646). The instrument was tested for acceptability and its subscales for internal consistency. Inter-rater reliability was estimated between two similar groups (n = 144 and n = 142) to test homogeneity. The adapted and translated instrument had a high acceptability (98.7% completed). The validation process shaped the adaptation, and resulted in strong criterion validity (R = 0.58, P < 0.01). The instrument subscales for risk factors and warning signs had high internal consistency (Cronbach's alpha 0.856 and 0.890, respectively), with all floor and ceiling effects less than 15%. The correlation measure for inter-rater reliability was 0.97 (P < 0.01). Through the incorporation of contextual characteristics and prevalent beliefs among Arab populations, the adapted Best Cancer Awareness Measure is a robust Arabic instrument for the measurement of breast cancer awareness and early detection practices among Arab women. The purposively selected sample may not be representative of the population. Improvement of awareness and early detection of breast cancer can contribute towards reducing mortality from the disease. The adapted instrument has policy implications, since measurement of awareness levels is essential towards breast health promotion policies in Arab countries. © 2016 International Council of Nurses.
Graff-Iversen, Sidsel; Anderssen, Sigmund Alfred; Holme, Ingar Morten; Jenum, Anne Karen; Raastad, Truls
2008-01-01
The aim was to indirectly validate two short postal questionnaires measuring leisure-time physical activity (LPA) by comparing the answers with serum lipids and anthropometric measurements. All inhabitants aged 31-67 years in two suburban, multicultural areas of Oslo, Norway were invited to "Romsås in Motion", a community intervention survey, in 2000. Of those, 2950 participants (48%) met and were re-invited in 2003. LPA was measured by two short instruments used since the 1970s (referred to as the Gothenburg instrument) and since 1994 in Cohort of Norway (CONOR). Each instrument was compared with relevant measurements at baseline including LPA according to an adapted version of the long International Physical Activity Questionnaire (IPAQ-L). In addition, changes during 2000--2003 in reported LPA were compared with changes in body weight, waist-to-hip ratio, lipids and other measurements. LPA measured by the Gothenburg instrument correlated weakly, but consistently with relevant biological and anthropometrical measurements and with IPAQ-L. The correlation coefficients were -0.1-(-0.2) with triglycerides, total-to-high density lipoprotein (HDL)-cholesterol ratio and waist-to-hip ratio, around 0.1 with HDL-cholesterol and 0.3 with maximal aerobic power. For the CONOR instrument a similar pattern was found in both sexes for the hard LPA and in women for light LPA. LPA measured by each short instrument was in line with LPA measured with IPAQ-L. In a multi-linguistic, suburban population in Oslo, Norway, LPA measurements by each of two short questionnaires were weakly, but consistently correlated with relevant biological and anthropometric measurements and strongly with IPAQ-L.
Quantification of hydrogen sulfide by near-infrared cavity ring-down spectroscopy
NASA Astrophysics Data System (ADS)
Rella, C.; Hoffnagle, J.; Wahl, E. H.; Kim-Hak, D.
2017-12-01
Hydrogen Sulfide is an important atmospheric sulfur species. Primary natural terrestrial sources of atmospheric H2S are volcanos and wetlands; primary anthropogenic sources are landfills; wastewater treatment facilities; sewer systems; natural gas extraction, production, and distribution; and paper manufacturing. The human nose is very sensitive to H2S and other sulfur species, leading to a significant negative impact of industrial processes in which H2S is emitted into the atmosphere. However, there is a relative lack of instrumentation capable of detecting and quantifying H2S at ppb levels and below. We describe an instrument based on cavity ring-down spectroscopy for the quantitative analysis of hydrogen sulfide concentration in ambient air. In addition to H2S, the instrument measures water vapor and methane. The instrument has a precision (1-sigma) of about 1 ppb at a measurement rate of 1 second, and provides measurements of less than 100 ppt with averaging. The instrument provides stable measurements (drift < 1 ppb) over long periods of time (days), and has a response time of just a couple of seconds. We report on ambient atmospheric measurements at a 10m urban tower, which demonstrate the suitability of the instrument for applications in urban sulfur emissions. This instrument is also suitable for soil flux measurements in a recirculating chamber, with predicted detection limit of about 0.6 μg H2S / m2 / hr and 0.45 μg CH4 / m2 / hr in a 10-minute chamber closure time.
Is it feasible to estimate radiosonde biases from interlaced measurements?
NASA Astrophysics Data System (ADS)
Kremser, Stefanie; Tradowsky, Jordis S.; Rust, Henning W.; Bodeker, Greg E.
2018-05-01
Upper-air measurements of essential climate variables (ECVs), such as temperature, are crucial for climate monitoring and climate change detection. Because of the internal variability of the climate system, many decades of measurements are typically required to robustly detect any trend in the climate data record. It is imperative for the records to be temporally homogeneous over many decades to confidently estimate any trend. Historically, records of upper-air measurements were primarily made for short-term weather forecasts and as such are seldom suitable for studying long-term climate change as they lack the required continuity and homogeneity. Recognizing this, the Global Climate Observing System (GCOS) Reference Upper-Air Network (GRUAN) has been established to provide reference-quality measurements of climate variables, such as temperature, pressure, and humidity, together with well-characterized and traceable estimates of the measurement uncertainty. To ensure that GRUAN data products are suitable to detect climate change, a scientifically robust instrument replacement strategy must always be adopted whenever there is a change in instrumentation. By fully characterizing any systematic differences between the old and new measurement system a temporally homogeneous data series can be created. One strategy is to operate both the old and new instruments in tandem for some overlap period to characterize any inter-instrument biases. However, this strategy can be prohibitively expensive at measurement sites operated by national weather services or research institutes. An alternative strategy that has been proposed is to alternate between the old and new instruments, so-called interlacing, and then statistically derive the systematic biases between the two instruments. Here we investigate the feasibility of such an approach specifically for radiosondes, i.e. flying the old and new instruments on alternating days. Synthetic data sets are used to explore the applicability of this statistical approach to radiosonde change management.
Use of Objective Metrics in Dynamic Facial Reanimation: A Systematic Review.
Revenaugh, Peter C; Smith, Ryan M; Plitt, Max A; Ishii, Lisa; Boahene, Kofi; Byrne, Patrick J
2018-06-21
Facial nerve deficits cause significant functional and social consequences for those affected. Existing techniques for dynamic restoration of facial nerve function are imperfect and result in a wide variety of outcomes. Currently, there is no standard objective instrument for facial movement as it relates to restorative techniques. To determine what objective instruments of midface movement are used in outcome measurements for patients treated with dynamic methods for facial paralysis. Database searches from January 1970 to June 2017 were performed in PubMed, Embase, Cochrane Library, Web of Science, and Scopus. Only English-language articles on studies performed in humans were considered. The search terms used were ("Surgical Flaps"[Mesh] OR "Nerve Transfer"[Mesh] OR "nerve graft" OR "nerve grafts") AND (face [mh] OR facial paralysis [mh]) AND (innervation [sh]) OR ("Face"[Mesh] OR facial paralysis [mh]) AND (reanimation [tiab]). Two independent reviewers evaluated the titles and abstracts of all articles and included those that reported objective outcomes of a surgical technique in at least 2 patients. The presence or absence of an objective instrument for evaluating outcomes of midface reanimation. Additional outcome measures were reproducibility of the test, reporting of symmetry, measurement of multiple variables, and test validity. Of 241 articles describing dynamic facial reanimation techniques, 49 (20.3%) reported objective outcome measures for 1898 patients. Of those articles reporting objective measures, there were 29 different instruments, only 3 of which reported all outcome measures. Although instruments are available to objectively measure facial movement after reanimation techniques, most studies do not report objective outcomes. Of objective facial reanimation instruments, few are reproducible and able to measure symmetry and multiple data points. To accurately compare objective outcomes in facial reanimation, a reproducible, objective, and universally applied instrument is needed.
Finch, Tracy L; Mair, Frances S; O'Donnell, Catherine; Murray, Elizabeth; May, Carl R
2012-05-17
Although empirical and theoretical understanding of processes of implementation in health care is advancing, translation of theory into structured measures that capture the complex interplay between interventions, individuals and context remain limited. This paper aimed to (1) describe the process and outcome of a project to develop a theory-based instrument for measuring implementation processes relating to e-health interventions; and (2) identify key issues and methodological challenges for advancing work in this field. A 30-item instrument (Technology Adoption Readiness Scale (TARS)) for measuring normalisation processes in the context of e-health service interventions was developed on the basis on Normalization Process Theory (NPT). NPT focuses on how new practices become routinely embedded within social contexts. The instrument was pre-tested in two health care settings in which e-health (electronic facilitation of healthcare decision-making and practice) was used by health care professionals. The developed instrument was pre-tested in two professional samples (N=46; N=231). Ratings of items representing normalisation 'processes' were significantly related to staff members' perceptions of whether or not e-health had become 'routine'. Key methodological challenges are discussed in relation to: translating multi-component theoretical constructs into simple questions; developing and choosing appropriate outcome measures; conducting multiple-stakeholder assessments; instrument and question framing; and more general issues for instrument development in practice contexts. To develop theory-derived measures of implementation process for progressing research in this field, four key recommendations are made relating to (1) greater attention to underlying theoretical assumptions and extent of translation work required; (2) the need for appropriate but flexible approaches to outcomes measurement; (3) representation of multiple perspectives and collaborative nature of work; and (4) emphasis on generic measurement approaches that can be flexibly tailored to particular contexts of study.
Instrumentation: Software-Driven Instrumentation: The New Wave.
ERIC Educational Resources Information Center
Salit, M. L.; Parsons, M. L.
1985-01-01
Software-driven instrumentation makes measurements that demand a computer as an integral part of either control, data acquisition, or data reduction. The structure of such instrumentation, hardware requirements, and software requirements are discussed. Examples of software-driven instrumentation (such as wavelength-modulated continuum source…
Instrument comparison for Aerosolized Titanium Dioxide
NASA Astrophysics Data System (ADS)
Ranpara, Anand
Recent toxicological studies have shown that the surface area of ultrafine particles (UFP i.e., particles with diameters less than 0.1 micrometer) has a stronger correlation with adverse health effects than does mass of these particles. Ultrafine titanium dioxide (TiO2) particles are widely used in industry, and their use is associated with adverse health outcomes, such as micro vascular dysfunctions and pulmonary damages. The primary aim of this experimental study was to compare a variety of laboratory and industrial hygiene (IH) field study instruments all measuring the same aerosolized TiO2. The study also observed intra-instrument variability between measurements made by two apparently identical devices of the same type of instrument placed side-by-side. The types of instruments studied were (1) DustTrak(TM) DRX, (2) Personal Data RAMs(TM) (PDR), (3) GRIMM, (4) Diffusion charger (DC) and (5) Scanning Mobility Particle Sizer (SMPS). Two devices of each of the four IH field study instrument types were used to measure six levels of mass concentration of fine and ultrafine TiO2 aerosols in controlled chamber tests. Metrics evaluated included real-time mass, active surface area and number/geometric surface area distributions, and off-line gravimetric mass and morphology on filters. DustTrak(TM) DRXs and PDRs were used for mass concentration measurements. DCs were used for active surface area concentration measurements. GRIMMs were used for number concentration measurements. SMPS was used for inter-instrument comparisons of surface area and number concentrations. The results indicated that two apparently identical devices of each DRX and PDR were statistically not different with each other for all the trials of both the sizes of powder (p < 5%). Mean difference between mass concentrations measured by two DustTrak DRX devices was smaller than that measured by two PDR devices. DustTrak DRX measurements were closer to the reference method, gravimetric mass concentration, than the PDRs. Two apparently identical DC devices were statistically different with each other for fine particles but not for UFP. DC devices and SMPS were statistically different with each other for both sizes of particles. Two apparently identical GRIMM devices were statistically different with each other for fine particles. For UFP, results of GRIMM device were statistically different than SMPS but not for fine particles. These observations suggest that inter-device within instrument and inter-instrument agreements depend on particle size and instrument characteristics to measure nanoparticles at different concentration levels.
Single-breath diffusing capacity for carbon monoxide instrument accuracy across 3 health systems.
Hegewald, Matthew J; Markewitz, Boaz A; Wilson, Emily L; Gallo, Heather M; Jensen, Robert L
2015-03-01
Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and repeatable D(LCO) values. D(LCO) instruments were tested with CO gas concentrations representing medium and high range D(LCO) values. The absolute difference between observed and target D(LCO) value was used to determine measurement accuracy; accuracy was defined as an average deviation from the target value of < 2.0 mL/min/mm Hg. Accuracy of inspired volume measurement and gas sensors were also determined. Twenty-three instruments were tested across 3 healthcare systems. The mean absolute deviation from the target value was 1.80 mL/min/mm Hg (range 0.24-4.23) with 10 of 23 instruments (43%) being inaccurate. High volume laboratories performed better than low volume laboratories, although the difference was not significant. There was no significant difference among the instruments by manufacturers. Inspired volume was not accurate in 48% of devices; mean absolute deviation from target value was 3.7%. Instrument gas analyzers performed adequately in all instruments. D(LCO) instrument accuracy was unacceptable in 43% of devices. Instrument inaccuracy can be primarily attributed to errors in inspired volume measurement and not gas analyzer performance. D(LCO) instrument performance may be improved by regular testing with a simulator. Caution should be used when comparing D(LCO) results reported from different laboratories. Copyright © 2015 by Daedalus Enterprises.
Jacobs, Philipp; Houben, Andreas; Schweika, Werner; Tchougréeff, Andrei L.; Dronskowski, Richard
2017-01-01
The method of angular- and wavelength-dispersive (e.g. two-dimensional) Rietveld refinement is a new and emerging tool for the analysis of neutron diffraction data measured at time-of-flight instruments with large area detectors. Following the approach for one-dimensional refinements (using either scattering angle or time of flight), the first step at each beam time cycle is the calibration of the instrument including the determination of instrumental contributions to the peak shape variation to be expected for diffraction patterns measured by the users. The aim of this work is to provide the users with calibration files and – for the later Rietveld refinement of the measured data – with an instrumental resolution file (IRF). This article will elaborate on the necessary steps to generate such an IRF for the angular- and wavelength-dispersive case, exemplified for the POWGEN instrument. A dataset measured on a standard diamond sample is used to extract the profile function in the two-dimensional case. It is found that the variation of reflection width with 2θ and λ can be expressed by the standard equation used for evaluating the instrumental resolution, which yields a substantially more fundamental approach to the parameterization of the instrumental contribution to the peak shape. Geometrical considerations of the POWGEN instrument and sample effects lead to values for Δθ, Δt and ΔL that yield a very good match to the extracted FWHM values. In a final step the refinement results are compared with the one-dimensional, i.e. diffraction-focused, case. PMID:28656041
Comparison of icing cloud instruments for 1982-1983 icing season flight program
NASA Technical Reports Server (NTRS)
Ide, R. F.; Richter, G. P.
1984-01-01
A number of modern and old style liquid water content (LWC) and droplet sizing instruments were mounted on a DeHavilland DHC-6 Twin Otter and operated in natural icing clouds in order to determine their comparative operating characteristics and their limitations over a broad range of conditions. The evaluation period occurred during the 1982-1983 icing season from January to March 1983. Time histories of all instrument outputs were plotted and analyzed to assess instrument repeatability and reliability. Scatter plots were also generated for comparison of instruments. The measured LWC from four instruments differed by as much as 20 percent. The measured droplet size from two instruments differed by an average of three microns. The overall effort demonstrated the need for additional data, and for some means of calibrating these instruments to known standards.
NASA Astrophysics Data System (ADS)
Wuest, Martin; Robinson, David W.; Decoste, Dennis
Calibration is defined as a set of operations that establish, under specified conditions, the relationship between the values of quantities indicated by a measuring instrument or measuring system and the corresponding values realized by standards. Calibration of an instrument means determining by how much the instrument reading is in error by checking it against a measurement standard of known error.Space physics particle instrumentation needs to be calibrated on the ground and inflight to insure that the data can be properly interpreted.On the ground, calibration is performed by exposing the instrument to a well characterized incident particle beam. Not only the nominal range of parameters the instrument is designed to measure should be calibrated but the instrument should also be exposed to out-of-band exposure such as higher energies, angles outside of the nominal field-of-view and susceptibility to ultraviolet radiation.There are several challenges to laboratory calibration on the ground. The beam must be well characterized in energy, angle, mass and position. The particle flux must be uniform over the whole aperture area of the instrument to be calibrated. The beam must be very stable in time and space. One of the difficulties arises that in order to measure the incident particle flux the beam monitor is placed upstream in front of the instrument thereby blocking the incident beam and interrupting the beam detection by the device under test. A beam monitor placed outside of the field-of-view of the instrument to be calibrated is often in a region at the fringes of the beam where the beam is not very stable. This basically prevents the measuring of the same beam with a trusted reference detector and the instrument under test at the same time. Further, highly sensitive instruments are calibrated at flux levels too low to be detected with stable Faraday cup detectors. Present day windowless electron multiplier detectors are able to measure the low flux levels but are sensitive to degradation as a function of contamination and the amount of extracted charge. Windowless electron multipliers are therefore not very stable reference detectors. This makes it difficult to obtain a reliable absolute calibration traceable to a national measurement institute. Calibration is still a time consuming process. It involves testing the instrument at component, subsystem and integrated level. It is important that the instrument is not only operated using a special calibration configuration to save time, but also in its full flight configuration exercising the full path of the data through data compression and telemetry. Very seldom there is enough time available to calibrate all the desired points in parameter space. Usually only a subset can be calibrated for schedule and economic reasons. The number of calibration points is often further reduced since the available calibration time is cut due to development schedule slip and a fixed launch date. This increases the uncertainties as more parameters have to be interpolated or extrapolated. Calibration data should be evaluated preferably in near-real time to prevent losing valuable calibration time if something in the instrument or facility is not working properly. Computer simulation models should be used to obtain a thorough understanding of the actual flight instrument. In flight the instrument performance degrades due to contamination (outgassing), environmental effects (atomic oxygen, radiation) or aging. One of the most sensitive parts in today's instrument are their detectors. Microchannel plate detectors degrade as function of the extracted charge. Solid-state detectors experience radiation damage which increases their noise and the lower energy detection threshold. The goal of the in-flight calibration is to determine this instrument degradation. Calibration is then performed by comparing measurements taken with different bias voltage or discriminator threshold settings. If possible, the instrument data is compared with other sensors covering the same or at least a part of the same measurand on the same or on a different spacecraft. In-flight calibration is not easy, as no absolute calibration standard for particles exist in space and measuring the same physical quantity with two different spacecraft at the same environmental conditions is very challenging.
Airborne intercomparison of nitric oxide measurement techniques
NASA Technical Reports Server (NTRS)
Hoell, James M., Jr.; Gregory, Gerald L.; Mcdougal, David S.; Torres, Arnold L.; Davis, Douglas D.
1987-01-01
Results from an airborne intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted during missions flown in the fall of 1983 and spring of 1984. Instruments intercompared included a laser-induced fluorescence (LIF) system and two chemiluminescence instruments (CL). NO mixing ratios from below 5 pptv (parts per trillion by volume) to greater than 100 pptv were reported, with the majority less than 20 pptv. Good correlation was observed between the measurements reported by the CL and LIF techniques. The general level of agreement observed for the ensemble of measurements obtained during the two missions provides the basis from which one can conclude that equally 'valid' measurements of background levels of NO can be expected from either CL or LIF instruments. At the same time the periods of disagreement that were observed between the CL and LIF instruments as well as between the two CL instruments highlight the difficulty of obtaining reliable measurements with NO mixing ratios in the 5-20 pptv range and emphasize the vigilance that should be maintained in future NO measurements.
Avila, Agustín Brau; Mazo, Jorge Santolaria; Martín, Juan José Aguilar
2014-01-01
During the last years, the use of Portable Coordinate Measuring Machines (PCMMs) in industry has increased considerably, mostly due to their flexibility for accomplishing in-line measuring tasks as well as their reduced costs and operational advantages as compared to traditional coordinate measuring machines (CMMs). However, their operation has a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification procedures. In this work the mechanical design of an indexed metrology platform (IMP) is presented. The aim of the IMP is to increase the final accuracy and to radically simplify the calibration, identification and verification of geometrical parameter procedures of PCMMs. The IMP allows us to fix the calibrated gauge object and move the measuring instrument in such a way that it is possible to cover most of the instrument working volume, reducing the time and operator fatigue to carry out these types of procedures. PMID:24451458
Avila, Agustín Brau; Mazo, Jorge Santolaria; Martín, Juan José Aguilar
2014-01-02
During the last years, the use of Portable Coordinate Measuring Machines (PCMMs) in industry has increased considerably, mostly due to their flexibility for accomplishing in-line measuring tasks as well as their reduced costs and operational advantages as compared to traditional coordinate measuring machines (CMMs). However, their operation has a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification procedures. In this work the mechanical design of an indexed metrology platform (IMP) is presented. The aim of the IMP is to increase the final accuracy and to radically simplify the calibration, identification and verification of geometrical parameter procedures of PCMMs. The IMP allows us to fix the calibrated gauge object and move the measuring instrument in such a way that it is possible to cover most of the instrument working volume, reducing the time and operator fatigue to carry out these types of procedures.
Walters, Stephen John; Stern, Cindy; Robertson-Malt, Suzanne
2016-04-01
There is a growing call by consumers and governments for healthcare to adopt systems and approaches to care to improve patient safety. Collaboration within healthcare settings is an important factor for improving systems of care. By using validated measurement instruments a standardized approach to assessing collaboration is possible, otherwise it is only an assumption that collaboration is occurring in any healthcare setting. The objective of this review was to evaluate and compare measurement properties of instruments that measure collaboration within healthcare settings, specifically those which have been psychometrically tested and validated. Participants could be healthcare professionals, the patient or any non-professional who contributes to a patient's care, for example, family members, chaplains or orderlies. The term participant type means the designation of any one participant; for example 'nurse', 'social worker' or 'administrator'. More than two participant types was mandatory. The focus of this review was the validity of tools used to measure collaboration within healthcare settings. The types of studies considered for inclusion were validation studies, but quantitative study designs such as randomized controlled trials, controlled trials and case studies were also eligible for inclusion. Studies that focused on Interprofessional Education, were published as an abstract only, contained patient self-reporting only or were not about care delivery were excluded. The outcome of interest was validation and interpretability of the instrument being assessed and included content validity, construct validity and reliability. Interpretability is characterized by statistics such as mean and standard deviation which can be translated to a qualitative meaning. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in this review. The databases searched included PubMed, CINAHL, Embase, Cochrane Central Register of Controlled Trials, Emerald Fulltext, MD Consult Australia, PsycARTICLES, Psychology and Behavioural Sciences Collection, PsycINFO, Informit Health Databases, Scopus, UpToDate and Web of Science. The search for unpublished studies included EThOS (Electronic Thesis Online Service), Index to Theses and ProQuest- Dissertations and Theses. The assessment of methodological quality of the included studies was undertaken using the COSMIN checklist which is a validated tool that assesses the process of design and validation of healthcare measurement instruments. An Excel spreadsheet version of COSMIN was developed for data collection which included a worksheet for extracting participant characteristics and interpretability data. Statistical pooling of data was not possible for this review. Therefore, the findings are presented in a narrative form including tables and figures to aid in data presentation. To make a synthesis of the assessments of methodological quality of the different studies, each instrument was rated by accounting for the number of studies performed with an instrument, the appraisal of methodological quality and the consistency of results between studies. Twenty-one studies of 12 instruments were included in the review. The studies were diverse in their theoretical underpinnings, target population/setting and measurement objectives. Measurement objectives included: investigating beliefs, behaviors, attitudes, perceptions and relationships associated with collaboration; measuring collaboration between different levels of care or within a multi-rater/target group; assessing collaboration across teams; or assessing internal participation of both teams and patients.Studies produced validity or interpretability data but none of the studies assessed all validity and reliability properties. However, most of the included studies produced a factor structure or referred to prior factor analysis. A narrative synthesis of the individual study factor structures was generated consisting of nine headings: organizational settings, support structures, purpose and goals; communication; reflection on process; cooperation; coordination; role interdependence and partnership; relationships; newly created professional activities; and professional flexibility. Among the many instruments that measure collaboration within healthcare settings, the quality of each instrument varies; instruments are designed for specific populations and purposes, and are validated in various settings. Selecting an instrument requires careful consideration of the qualities of each. Therefore, referring to systematic reviews of measurement properties of instruments may be helpful to clinicians or researchers in instrument selection. Systematic reviews of measurement properties of instruments are valuable in aiding in instrument selection. This systematic review may be useful in instrument selection for the measurement of collaboration within healthcare settings with a complex mix of participant types. Evaluating collaboration provides important information on the strengths and limitations of different healthcare settings and the opportunities for continuous improvement via any remedial actions initiated. Development of a tool that can be used to measure collaboration within teams of healthcare professionals and non-professionals is important for practice. The use of different statistical modelling techniques, such as Item Response Theory modelling and the translation of models into Computer Adaptive Tests, may prove useful. Measurement equivalence is an important consideration for future instrument development and validation. Further development of the COSMIN tool should include appraisal for measurement equivalence. Researchers developing and validating measurement tools should consider multi-method research designs.
An Integrative Review of Self-Efficacy Measurement Instruments in Youth with Type 1 Diabetes (T1DM)
Rasbach, Lisa; Jenkins, Carolyn; Laffel, Lori
2014-01-01
Purpose The purpose of this study is to assess the extant literature on instruments used to measure self-efficacy in youth with type 1 diabetes (T1DM) and their caregivers and to critically evaluate these measurements. Methods An integrative review (2003–2013) was conducted searching PsycINFO, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and U.S. National Library of Medicine PubMed service (PubMed) databases using key words diabetes, type 1 diabetes, and self-efficacy. The authors reviewed the resulting294 references for inclusion criteria of (a) sample of youth with T1DM or sample of caregivers of youth with T1DM, (b) description of the self-efficacy instrument as primary research, and (c) the instrument measured self-efficacy specifically related to diabetes management. Forty-five articles out of the initial 294 met criteria. Results Of the 45 articles, 10 different self-efficacy instruments were identified. The primary theoretical framework used was Bandura’s social cognitive theory and model of self-efficacy. Most participants were white middle class T1DM youth. Evaluations to assess validity often were not reported; however, a majority of studies reported high internal consistency of the instruments. Conclusions Sample homogeneity could limit the applicability of results to certain patient populations. Further psychometric analysis, including validity assessments, should be conducted in more diverse samples. Development of valid and reliable instruments for measuring self-efficacy that are sensitive to change across a wider caregiver base over time is necessary. While this review examined reliable and valid instruments used in research, future opportunities include evaluation of measuring self-efficacy in T1DM youth exposed to recent advances in diabetes management technologies. PMID:25216655
On Aethalometer measurement uncertainties and an instrument correction factor for the Arctic
NASA Astrophysics Data System (ADS)
Backman, John; Schmeisser, Lauren; Virkkula, Aki; Ogren, John A.; Asmi, Eija; Starkweather, Sandra; Sharma, Sangeeta; Eleftheriadis, Konstantinos; Uttal, Taneil; Jefferson, Anne; Bergin, Michael; Makshtas, Alexander; Tunved, Peter; Fiebig, Markus
2017-12-01
Several types of filter-based instruments are used to estimate aerosol light absorption coefficients. Two significant results are presented based on Aethalometer measurements at six Arctic stations from 2012 to 2014. First, an alternative method of post-processing the Aethalometer data is presented, which reduces measurement noise and lowers the detection limit of the instrument more effectively than boxcar averaging. The biggest benefit of this approach can be achieved if instrument drift is minimised. Moreover, by using an attenuation threshold criterion for data post-processing, the relative uncertainty from the electronic noise of the instrument is kept constant. This approach results in a time series with a variable collection time (Δt) but with a constant relative uncertainty with regard to electronic noise in the instrument. An additional advantage of this method is that the detection limit of the instrument will be lowered at small aerosol concentrations at the expense of temporal resolution, whereas there is little to no loss in temporal resolution at high aerosol concentrations ( > 2.1-6.7 Mm-1 as measured by the Aethalometers). At high aerosol concentrations, minimising the detection limit of the instrument is less critical. Additionally, utilising co-located filter-based absorption photometers, a correction factor is presented for the Arctic that can be used in Aethalometer corrections available in literature. The correction factor of 3.45 was calculated for low-elevation Arctic stations. This correction factor harmonises Aethalometer attenuation coefficients with light absorption coefficients as measured by the co-located light absorption photometers. Using one correction factor for Arctic Aethalometers has the advantage that measurements between stations become more inter-comparable.
Anigstein, Robert; Erdman, Michael C.; Ansari, Armin
2017-01-01
The detonation of a radiological dispersion device or other radiological incidents could result in the dispersion of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure photon radiation from radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for further assessments. Computer simulations and experimental measurements are required for these instruments to be used for assessing intakes of radionuclides. Count rates from calibrated sources of 60Co, 137Cs, and 241Am were measured on three instruments: a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal, a thyroid probe using a 5.08 × 5.08-cm NaI(Tl) crystal, and a portal monitor incorporating two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators. Computer models of the instruments and of the calibration sources were constructed, using engineering drawings and other data provided by the manufacturers. Count rates on the instruments were simulated using the Monte Carlo radiation transport code MCNPX. The computer simulations were within 16% of the measured count rates for all 20 measurements without using empirical radionuclide-dependent scaling factors, as reported by others. The weighted root-mean-square deviations (differences between measured and simulated count rates, added in quadrature and weighted by the variance of the difference) were 10.9% for the survey meter, 4.2% for the thyroid probe, and 0.9% for the portal monitor. These results validate earlier MCNPX models of these instruments that were used to develop calibration factors that enable these instruments to be used for assessing intakes and committed doses from several gamma-emitting radionuclides. PMID:27115229
Smith, Shannon M; Paillard, Florence; McKeown, Andrew; Burke, Laurie B; Edwards, Robert R; Katz, Nathaniel P; Papadopoulos, Elektra J; Rappaport, Bob A; Slagle, Ashley; Strain, Eric C; Wasan, Ajay D; Turk, Dennis C; Dworkin, Robert H
2015-05-01
Measurement of inappropriate medication use events (eg, abuse or misuse) in clinical trials is important in characterizing a medication's abuse potential. However, no gold standard assessment of inappropriate use events in clinical trials has been identified. In this systematic review, we examine the measurement properties (ie, content validity, cross-sectional reliability and construct validity, longitudinal construct validity, ability to detect change, and responder definitions) of instruments assessing inappropriate use of opioid and nonopioid prescription medications to identify any that meet U.S. and European regulatory agencies' rigorous standards for outcome measures in clinical trials. Sixteen published instruments were identified, most of which were not designed for the selected concept of interest and context of use. For this reason, many instruments were found to lack adequate content validity (or documentation of content validity) to evaluate current inappropriate medication use events; for example, evaluating inappropriate use across the life span rather than current use, including items that did not directly assess inappropriate use (eg, questions about anger), or failing to capture information pertinent to inappropriate use events (eg, intention and route of administration). In addition, the psychometric data across all instruments were generally limited in scope. A further limitation is the heterogeneous, nonstandardized use of inappropriate medication use terminology. These observations suggest that available instruments are not well suited for assessing current inappropriate medication use within the specific context of clinical trials. Further effort is needed to develop reliable and valid instruments to measure current inappropriate medication use events in clinical trials. This systematic review evaluates the measurement properties of inappropriate medication use (eg, abuse or misuse) instruments to determine whether any meet regulatory standards for clinical trial outcome measures to assess abuse potential. Copyright © 2015 American Pain Society. All rights reserved.
Anigstein, Robert; Erdman, Michael C; Ansari, Armin
2016-06-01
The detonation of a radiological dispersion device or other radiological incidents could result in the dispersion of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure photon radiation from radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for further assessments. Computer simulations and experimental measurements are required for these instruments to be used for assessing intakes of radionuclides. Count rates from calibrated sources of Co, Cs, and Am were measured on three instruments: a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal, a thyroid probe using a 5.08 × 5.08-cm NaI(Tl) crystal, and a portal monitor incorporating two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators. Computer models of the instruments and of the calibration sources were constructed, using engineering drawings and other data provided by the manufacturers. Count rates on the instruments were simulated using the Monte Carlo radiation transport code MCNPX. The computer simulations were within 16% of the measured count rates for all 20 measurements without using empirical radionuclide-dependent scaling factors, as reported by others. The weighted root-mean-square deviations (differences between measured and simulated count rates, added in quadrature and weighted by the variance of the difference) were 10.9% for the survey meter, 4.2% for the thyroid probe, and 0.9% for the portal monitor. These results validate earlier MCNPX models of these instruments that were used to develop calibration factors that enable these instruments to be used for assessing intakes and committed doses from several gamma-emitting radionuclides.
Measuring Room Area or Volume Electronically
NASA Technical Reports Server (NTRS)
Kavaya, M. J.
1987-01-01
Area- and volume-measuring instrument hand-held or mounted on tripod. Instrument rapidly measures distances to walls, ceiling, or floor at many viewing angles and automatically computes area or volume of room. Results obtained rapidly with minimal effort.
Hyperspectral imaging spectro radiometer improves radiometric accuracy
NASA Astrophysics Data System (ADS)
Prel, Florent; Moreau, Louis; Bouchard, Robert; Bullis, Ritchie D.; Roy, Claude; Vallières, Christian; Levesque, Luc
2013-06-01
Reliable and accurate infrared characterization is necessary to measure the specific spectral signatures of aircrafts and associated infrared counter-measures protections (i.e. flares). Infrared characterization is essential to improve counter measures efficiency, improve friend-foe identification and reduce the risk of friendly fire. Typical infrared characterization measurement setups include a variety of panchromatic cameras and spectroradiometers. Each instrument brings essential information; cameras measure the spatial distribution of targets and spectroradiometers provide the spectral distribution of the emitted energy. However, the combination of separate instruments brings out possible radiometric errors and uncertainties that can be reduced with Hyperspectral imagers. These instruments combine both spectral and spatial information into the same data. These instruments measure both the spectral and spatial distribution of the energy at the same time ensuring the temporal and spatial cohesion of collected information. This paper presents a quantitative analysis of the main contributors of radiometric uncertainties and shows how a hyperspectral imager can reduce these uncertainties.
Otterman, Nicoline; Veerbeek, Janne; Schiemanck, Sven; van der Wees, Philip; Nollet, Frans; Kwakkel, Gert
2017-07-01
To select relevant and feasible instruments for the revision of the Dutch clinical practice guideline for physical therapy in patients with stroke. In this implementation study a comprehensive proposal for ICF categories and matching instruments was developed, based on reliability and validity. Relevant instruments were then selected in a consensus round by 11 knowledge brokers who were responsible for the implementation of the selected instruments. The feasibility of the selected instruments was tested by 36 physical therapists at different work settings within stroke services. Finally, instruments that were deemed relevant and feasible were included in the revised guideline. A total of 28 instruments were recommended for inclusion in the revised guideline. Nineteen instruments were retained from the previous guideline. Ten new instruments were tested in clinical practice, seven of which were found feasible. Two more instruments were added after critical appraisal of the set of the measurement instruments. The revised guideline contains 28 relevant and feasible instrument selected and tested in clinical practice by physical therapists. Further education and implementation is needed to integrate instruments in clinical practice. Further research is proposed for developing and implementing a core set of measurement instruments to be used at fixed time points to establish data registries that allow for continuous improvement of rehabilitation for stroke patients. Implications for Rehabilitation The revised Dutch Stroke Physical Therapy Guideline recommends a total of 28 instruments, that are relevant and feasible for clinical practice of physical therapist in the different settings of stroke rehabilitation. The selection of instrument in daily practice should be part of the clinical reasoning process of PTs and be tailored to individual patients' needs and the degree of priority of the affected ICF category. Suggested education strategies for further integration of instruments in of the daily practice of PTs in Stroke Rehabilitation are: 'Training on the job' and 'peer assessment in clinical situations'.
ERIC Educational Resources Information Center
Liou, Pey-Yan; Kuo, Pei-Jung
2014-01-01
Background: Few studies have examined students' attitudinal perceptions of technology. There is no appropriate instrument to measure senior high school students' motivation and self-regulation toward technology learning among the current existing instruments in the field of technology education. Purpose: The present study is to validate an…
ERIC Educational Resources Information Center
Lin, Hsin-Hui; Wang, Yi-Shun; Li, Ci-Rong; Shih, Ying-Wei; Lin, Shin-Jeng
2017-01-01
The main purpose of this study is to develop and validate a multidimensional instrument for measuring mobile learning systems success (MLSS) based on the previous research. This study defines the construct of MLSS, develops a generic MLSS instrument with desirable psychometric properties, and explores the instrument's theoretical and practical…
Measuring Middle Grades Teachers' Understanding of Rational Numbers with the Mixture Rasch Model
ERIC Educational Resources Information Center
Izsak, Andrew; Orrill, Chandra Hawley; Cohen, Allan S.; Brown, Rachael Eriksen
2010-01-01
We report the development of a multiple-choice instrument that measures the mathematical knowledge needed for teaching arithmetic with fractions, decimals, and proportions. In particular, the instrument emphasizes the knowledge needed to reason about such arithmetic when numbers are embedded in problem situations. We administered our instrument to…
Physical Activity Measurement Instruments for Children with Cerebral Palsy: A Systematic Review
ERIC Educational Resources Information Center
Capio, Catherine M.; Sit, Cindy H. P.; Abernethy, Bruce; Rotor, Esmerita R.
2010-01-01
Aim: This paper is a systematic review of physical activity measurement instruments for field-based studies involving children with cerebral palsy (CP). Method: Database searches using PubMed Central, MEDLINE, CINAHL Plus, PsycINFO, EMBASE, Cochrane Library, and PEDro located 12 research papers, identifying seven instruments that met the inclusion…
ERIC Educational Resources Information Center
Daniel, Larry G.; And Others
1997-01-01
Factor analysis of data from 213 college business students supported the existence of 5 constructs for the Ethical Issues Rating Scale, an instrument measuring respondents' assessment of the importance of various ethical issues. Suggestions about refining the instrument and using it are discussed. (SLD)
ERIC Educational Resources Information Center
Shecter, Julie
2009-01-01
Many universities implement programs and interventions to increase students' perceived instrumental social support within the classroom setting, yet to date, no measures exist to adequately assess such perceptions. In response to this need, the current research developed an operational definition of instrumental classroom social support and also…
NASA Astrophysics Data System (ADS)
Sari, Anggi Ristiyana Puspita; Suyanta, LFX, Endang Widjajanti; Rohaeti, Eli
2017-05-01
Recognizing the importance of the development of critical thinking and science process skills, the instrument should give attention to the characteristics of chemistry. Therefore, constructing an accurate instrument for measuring those skills is important. However, the integrated instrument assessment is limited in number. The purpose of this study is to validate an integrated assessment instrument for measuring students' critical thinking and science process skills on acid base matter. The development model of the test instrument adapted McIntire model. The sample consisted of 392 second grade high school students in the academic year of 2015/2016 in Yogyakarta. Exploratory Factor Analysis (EFA) was conducted to explore construct validity, whereas content validity was substantiated by Aiken's formula. The result shows that the KMO test is 0.714 which indicates sufficient items for each factor and the Bartlett test is significant (a significance value of less than 0.05). Furthermore, content validity coefficient which is based on 8 experts is obtained at 0.85. The findings support the integrated assessment instrument to measure critical thinking and science process skills on acid base matter.
NASA Technical Reports Server (NTRS)
Petro, Elaine; Hughes, David
2011-01-01
Analysis has been performed for MAVEN mission. Due to the elliptical orbit, large pressure variations in orbit will be experienced, there is a need to understand how internal pressures change and the flux of gas from vents could potentially bias instrument measurements. Goal of this analysis is to predict the effect that atmospheric gases trapped and vented from spacecraft volumes could have on instrument measurements.
Horizontal film balance having wide range and high sensitivity
Abraham, B.M.; Miyano, K.; Ketterson, J.B.
1981-03-05
A thin-film, horizontal balance instrument is provided for measuring surface tension (surface energy) of thin films suspended on a liquid substrate. The balance includes a support bearing and an optical feedback arrangement for wide-range, high sensitivity measurements. The force on the instrument is balanced by an electromagnet, the current through the magnet providing a measure of the force applied to the instrument. A novel float construction is also disclosed.
Horizontal film balance having wide range and high sensitivity
Abraham, B.M.; Miyano, K.; Ketterson, J.B.
1983-11-08
A thin-film, horizontal balance instrument is provided for measuring surface tension (surface energy) of thin films suspended on a liquid substrate. The balance includes a support bearing and an optical feedback arrangement for wide-range, high sensitivity measurements. The force on the instrument is balanced by an electromagnet, the current through the magnet providing a measure of the force applied to the instrument. A novel float construction is also disclosed. 5 figs.
Horizontal film balance having wide range and high sensitivity
Abraham, Bernard M.; Miyano, Kenjiro; Ketterson, John B.
1983-01-01
A thin-film, horizontal balance instrument is provided for measuring surface tension (surface energy) of thin films suspended on a liquid substrate. The balance includes a support bearing and an optical feedback arrangement for wide-range, high sensitivity measurements. The force on the instrument is balanced by an electromagnet, the current through the magnet providing a measure of the force applied to the instrument. A novel float construction is also disclosed.
NASA Technical Reports Server (NTRS)
Lesco, D. J.; Weikle, D. H.
1980-01-01
The wideband electric power measurement related topics of electronic wattmeter calibration and specification are discussed. Tested calibration techniques are described in detail. Analytical methods used to determine the bandwidth requirements of instrumentation for switching circuit waveforms are presented and illustrated with examples from electric vehicle type applications. Analog multiplier wattmeters, digital wattmeters and calculating digital oscilloscopes are compared. The instrumentation characteristics which are critical to accurate wideband power measurement are described.
Lischka, Alyson E; Garner, Mary
In this paper we present the development and validation of a Mathematics Teaching Pedagogical and Discourse Beliefs Instrument (MTPDBI), a 20 item partial-credit survey designed and analyzed using Rasch measurement theory. Items on the MTPDBI address beliefs about the nature of mathematics, teaching and learning mathematics, and classroom discourse practices. A Rasch partial credit model (Masters, 1982) was estimated from the pilot study data. Results show that item separation reliability is .96 and person separation reliability is .71. Other analyses indicate the instrument is a viable measure of secondary teachers' beliefs about reform-oriented mathematics teaching and learning. This instrument is proposed as a useful measure of teacher beliefs for those working with pre-service and in-service teacher development.
NASA Technical Reports Server (NTRS)
Barbier, Louis M.; Smith, Robert; Murphy, Scott; Christian, Eric R.; Farley, Rodger; Krizmanic, John F.; Mitchell, John W.; Streitmatter, Robert E.; Loh, Eugene C.; Stochaj, Stephen
2004-01-01
We have designed and built an instrument to measure and monitor the "nightglow" of the Earth's atmosphere in the near ultraviolet (NUV). In this paper we describe the design of this instrument, called NIGHTGLOW. NIGHTGLOW is designed to be flown-from a high altitude research balloon, and circumnavigate the globe. NIGHTGLOW is a NASA, University of Utah, and New Mexico State University project. A test flight took place from Palestine, Texas on July 5, 2000, lasting about 8 hours. The instrument performed well and landed safely in Stiles, Texas with little damage. The resulting measurements of the NUV nightglow are consistent with previous measurements from sounding rockets and balloons. The results will be presented and discussed.
Computerized data reduction techniques for nadir viewing remote sensors
NASA Technical Reports Server (NTRS)
Tiwari, S. N.; Gormsen, Barbara B.
1985-01-01
Computer resources have been developed for the analysis and reduction of MAPS experimental data from the OSTA-1 payload. The MAPS Research Project is concerned with the measurement of the global distribution of mid-tropospheric carbon monoxide. The measurement technique for the MAPS instrument is based on non-dispersive gas filter radiometer operating in the nadir viewing mode. The MAPS experiment has two passive remote sensing instruments, the prototype instrument which is used to measure tropospheric air pollution from aircraft platforms and the third generation (OSTA) instrument which is used to measure carbon monoxide in the mid and upper troposphere from space platforms. Extensive effort was also expended in support of the MAPS/OSTA-3 shuttle flight. Specific capabilities and resources developed are discussed.
COBE - New sky maps of the early universe
NASA Technical Reports Server (NTRS)
Smoot, G. F.
1991-01-01
This paper presents early results obtained from the first six months of measurements of the cosmic microwave background (CMB) by instruments aboard NASA's Cosmic Background Explorer (COBE) satellite and discusses the implications for cosmology. The three instruments: FIRAS, DMR, and DIRBE have operated well and produced significant new results. The FIRAS measurement of the CMB spectrum supports the standard big bang nucleosynthesis model. The maps made from the DMR instrument measurements show a surprisingly smooth early universe. The measurements are sufficiently precise that we must pay careful attention to potential systematic errors. The maps of galactic and local emission produced by the DIRBE instrument will be needed to identify foregrounds from extragalactic emission and thus to interpret the terms of events in the early universe.
Pulse energy measurement at the SXR instrument
Moeller, Stefan; Brown, Garth; Dakovski, Georgi; ...
2015-04-14
A gas monitor detector was implemented and characterized at the Soft X-ray Research (SXR) instrument to measure the average, absolute and pulse-resolved photon flux of the LCLS beam in the energy range between 280 and 2000 eV. The detector is placed after the monochromator and addresses the need to provide reliable absolute pulse energy as well as pulse-resolved measurements for the various experiments at this instrument. This detector provides a reliable non-invasive measurement for determining flux levels on the samples in the downstream experimental chamber and for optimizing signal levels of secondary detectors and for the essential need of datamore » normalization. The design, integration into the instrument and operation are described, and examples of its performance are given.« less
West, Michael D; Charles, Christine; Boswell, Rod W
2009-05-01
A high sensitivity momentum flux measuring instrument based on a compound pendulum has been developed for use with electric propulsion devices and radio frequency driven plasmas. A laser displacement system, which builds upon techniques used by the materials science community for surface stress measurements, is used to measure with high sensitivity the displacement of a target plate placed in a plasma thruster exhaust. The instrument has been installed inside a vacuum chamber and calibrated via two different methods and is able to measure forces in the range of 0.02-0.5 mN with a resolution of 15 microN. Measurements have been made of the force produced from the cold gas flow and with a discharge ignited using argon propellant. The plasma is generated using a Helicon Double Layer Thruster prototype. The instrument target is placed about 1 mean free path for ion-neutral charge exchange collisions downstream of the thruster exit. At this position, the plasma consists of a low density ion beam (10%) and a much larger downstream component (90%). The results are in good agreement with those determined from the plasma parameters measured with diagnostic probes. Measurements at various flow rates show that variations in ion beam velocity and plasma density and the resulting momentum flux can be measured with this instrument. The instrument target is a simple, low cost device, and since the laser displacement system used is located outside the vacuum chamber, the measurement technique is free from radio frequency interference and thermal effects. It could be used to measure the thrust in the exhaust of other electric propulsion devices and the momentum flux of ion beams formed by expanding plasmas or fusion experiments.
Comparison of Satellite based Ion Density Measurements with Digisonde electron density measurements
NASA Astrophysics Data System (ADS)
Wilson, G.; Balthazor, R. L.; Reinisch, B. W.; McHarg, M.; Maldonado, C.
2017-12-01
The integrated Miniaturized Electrostatic Analyzer (IMESA) flying on the STPSat-3 satellite has collected more than 3 years of ion density data. This instrument is the first in a constellation of up to 6 instruments. We plan on integrating the data from all IMESAs into an approiate ionospheric model. OUr first step is to validate the IMESA data and calibrate the instrument. In this presentation we discuss our process for preparing IMESA data and comparing it to ground based measurements. Lastly, we present a number of comparisons between IMESA ion density measurements and digisonde electron density measurements.
Investigation of converging and collimated beam instrument geometry on specular gloss measurements
NASA Astrophysics Data System (ADS)
Zwinkels, Joanne C.; Côté, Éric; Morgan, John
2018-02-01
Specular gloss is an important appearance property of a wide variety of manufactured goods. Depending upon the application, e.g. paints, paper, ceramics, etc. different instrument designs and measurement geometries are specified in standard test methods. For a given specular angle, these instrument designs can be broadly classified as converging beam (TAPPI method) and collimated beam (DIN method). In recent comparisons of specular gloss measurements using different glossmeters, very large standard deviations have been reported, well exceeding the manufacturers claims. In this paper, we investigate the effect of instrument beam geometry on gloss measurements. These results indicate that this difference in beam geometry can give the magnitude of gloss differences reported in these comparisons and highlights the importance of educating the user community of best measurement practices and obtaining appropriate traceability for their glossmeters.
The brief negative symptom scale: psychometric properties.
Kirkpatrick, Brian; Strauss, Gregory P; Nguyen, Linh; Fischer, Bernard A; Daniel, David G; Cienfuegos, Angel; Marder, Stephen R
2011-03-01
The participants in the NIMH-MATRICS Consensus Development Conference on Negative Symptoms recommended that an instrument be developed that measured blunted affect, alogia, asociality, anhedonia, and avolition. The Brief Negative Symptom Scale (BNSS) is a 13-item instrument designed for clinical trials and other studies that measures these 5 domains. The interrater, test-retest, and internal consistency of the instrument were strong, with respective intraclass correlation coefficients of 0.93 for the BNSS total score and values of 0.89-0.95 for individual subscales. Comparisons with positive symptoms and other negative symptom instruments supported the discriminant and concurrent validity of the instrument.
NASA Technical Reports Server (NTRS)
Earnshaw, K. B.; Hernandez, E. N.
1972-01-01
The Wave Propagation Laboratory of the Environmental Research Laboratories of the National Oceanic and Atmospheric Administration has been engaged in the development of dual-wavelength, optical distance-measuring instruments. Recently a new generation of this type of high-accuracy instrument has been completed. Preliminary testing of the new instrument indicates that the original goal of the project, accuracy of better than one part in a million over distances of 5-10 km using averaging times of less than 1 min, is being met. This paper describes the instrument and preliminary test results.
Quantifying the value of redundant measurements at GCOS Reference Upper-Air Network sites
Madonna, F.; Rosoldi, M.; Güldner, J.; ...
2014-11-19
The potential for measurement redundancy to reduce uncertainty in atmospheric variables has not been investigated comprehensively for climate observations. We evaluated the usefulness of entropy and mutual correlation concepts, as defined in information theory, for quantifying random uncertainty and redundancy in time series of the integrated water vapour (IWV) and water vapour mixing ratio profiles provided by five highly instrumented GRUAN (GCOS, Global Climate Observing System, Reference Upper-Air Network) stations in 2010–2012. Results show that the random uncertainties on the IWV measured with radiosondes, global positioning system, microwave and infrared radiometers, and Raman lidar measurements differed by less than 8%.more » Comparisons of time series of IWV content from ground-based remote sensing instruments with in situ soundings showed that microwave radiometers have the highest redundancy with the IWV time series measured by radiosondes and therefore the highest potential to reduce the random uncertainty of the radiosondes time series. Moreover, the random uncertainty of a time series from one instrument can be reduced by ~ 60% by constraining the measurements with those from another instrument. The best reduction of random uncertainty is achieved by conditioning Raman lidar measurements with microwave radiometer measurements. In conclusion, specific instruments are recommended for atmospheric water vapour measurements at GRUAN sites. This approach can be applied to the study of redundant measurements for other climate variables.« less
Instrument Reporting Practices in Second Language Research
ERIC Educational Resources Information Center
Derrick, Deirdre J.
2016-01-01
Second language (L2) researchers often have to develop or change the instruments they use to measure numerous constructs (Norris & Ortega, 2012). Given the prevalence of researcher-developed and -adapted data collection instruments, and given the profound effect instrumentation can have on results, thorough reporting of instrumentation is…
Measurement properties of outcome measures for vitiligo. A systematic review.
Vrijman, Charlotte; Linthorst Homan, May W; Limpens, Jacqueline; van der Veen, Wietze; Wolkerstorfer, Albert; Terwee, Caroline B; Spuls, Phyllis I
2012-11-01
OBJECTIVE To summarize and critically appraise the evidence on the measurement properties of clinician-, patient-, and observer-reported outcomes, measuring any construct of interest in patients with all types of vitiligo. DATA SOURCES Electronic databases including PubMed (1948 to July 2011), OVID EMBASE (1980 to July 2011), and CINAHL (EBSCOhost) (1982 to July 2011) were searched. STUDY SELECTION Two authors independently screened all records for eligibility. For inclusion, the study population had to include patients with vitiligo, for which outcome measures were developed or evaluated on their measurement properties. The initial search retrieved 1249 records, of which 14 articles met the inclusion criteria. DATA EXTRACTION Characteristics of the included instruments, study population, and results of the measurement properties were extracted. The Consensus-Based Standards for the Selection of Health Status Measurement Instruments (COSMIN) 4-point checklist, combined with quality criteria for measurement properties, was used to calculate the overall level of evidence per measurement property of each instrument. Independent extraction and assessment was performed by 2 authors. DATA SYNTHESIS Eleven different measurement instruments were identified. Strong evidence was found for a positive internal consistency of the Dermatology Life Quality Index. For other instruments, the evidence of measurement properties was limited or unknown. CONCLUSIONS Recommendations on the use of specific outcome measures for vitiligo should be formulated with caution because current evidence is insufficient owing to a low number of studies with poor methodological quality and unclear clinical relevance. To recommend outcome measures for vitiligo, further research on measurement properties of clinical relevant outcome measures for vitiligo according to COSMIN quality criteria is needed.
Testing Instrument for Flight-Simulator Displays
NASA Technical Reports Server (NTRS)
Haines, Richard F.
1987-01-01
Displays for flight-training simulators rapidly aligned with aid of integrated optical instrument. Calibrations and tests such as aligning boresight of display with respect to user's eyes, checking and adjusting display horizon, checking image sharpness, measuring illuminance of displayed scenes, and measuring distance of optical focus of scene performed with single unit. New instrument combines all measurement devices in single, compact, integrated unit. Requires just one initial setup. Employs laser and produces narrow, collimated beam for greater measurement accuracy. Uses only one moving part, double right prism, to position laser beam.
Spectroelectrochemical Instrument Measures TOC
NASA Technical Reports Server (NTRS)
Kounaves, Sam
2011-01-01
A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.
Plant moisture stress: a portable freezing-point meter compared with the psychrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cary, J.W.; Fisher, H.D.
A small portable instrument for measuring the freezing-point depression of plant tissue has been developed for field use. The instrument is easy to operate and can be constructed from materials costing less than $100. Moisture stress measurements made with the freezing-point meter on a variety of plants were compared with vapor pressure psychrometer measurements. Variation between duplicates in the freezing point averaged 1.2 bars, but differences between stress measurements made with the psychrometer and freezing-point instrument averaged 2.6 bars. 11 references, 5 figures, 2 tables.
A 40 Year Time Series of SBUV Observations: the Version 8.6 Processing
NASA Technical Reports Server (NTRS)
McPeters, Richard; Bhartia, P. K.; Flynn, L.
2012-01-01
Under a NASA program to produce long term data records from instruments on multiple satellites (MEaSUREs), data from a series of eight SBUV and SBUV 12 instruments have been reprocessed to create a 40 year long ozone time series. Data from the Nimbus 4 BUV, Nimbus 7 SBUV, and SBUV/2 instruments on NOAA 9, 11, 14, 16, 17, and 18 were used covering the period 1970 to 1972 and 1979 to the present. In past analyses an ozone time series was created from these instruments by adjusting ozone itself, instrument by instrument, for consistency during overlap periods. In the version 8.6 processing adjustments were made to the radiance calibration of each instrument to maintain a consistent calibration over the entire time series. Data for all eight instruments were then reprocessed using the adjusted radiances. Reprocessing is necessary to produce an accurate latitude dependence. Other improvements incorporated in version 8.6 included the use of the ozone cross sections of Brion, Daumont, and Malicet, and the use of a cloud height climatology derived from Aura OMI measurements. The new cross sections have a more accurate temperature dependence than the cross sections previously used. The OMI-based cloud heights account for the penetration of UV into the upper layers of clouds. The consistency of the version 8.6 time series was evaluated by intra-instrument comparisons during overlap periods, comparisons with ground-based instruments, and comparisons with measurements made by instruments on other satellites such as SAGE II and UARS MLS. These comparisons show that for the instruments on NOAA 16, 17 and 18, the instrument calibrations were remarkably stable and consistent from instrument to instrument. The data record from the Nimbus 7 SBUV was also very stable, and SAGE and ground-based comparisons show that the' calibration was consistent with measurements made years laterby the NOAA 16 instrument. The calibrations of the SBUV/2 instruments on NOAA 9, 11, and 14 were more of a problem. The rapidly drifting orbits of these satellites resulted in relative time and altitude dependent differences that are significant. Despite these problems, total column ozone appears to be consistent to better than 1% over the entire time series, while the ozone vertical distribution is consistent to approximately 5%.
NASA Astrophysics Data System (ADS)
Shaughnessy, B. M.; Eccleston, P.; Fereday, K. J.; Canfer, S. J.; Nørgaard-Nielsen, H. U.; Jessen, N. C.
2007-05-01
The Mid-Infrared Instrument (MIRI) is one of four instruments on the James Webb Space Telescope observatory, scheduled for launch in 2013. It must be cooled to about 7 K and is supported within the telescope’s 40 K instrument module by a hexapod of carbon fibre reinforced plastic (CFRP) tubing. This article describes the measurement of cryogenic thermal conductivity of the candidate CFRP. Measured thermal conductivities were about 0.05 W/m K at a mean temperature of 10 K increasing to about 0.20 W/m K at a mean temperature of 40 K.
Measuring Quality and Outcomes in Sports Medicine.
Ruzbarsky, Joseph J; Marom, Niv; Marx, Robert G
2018-07-01
Patient-reported outcome measures (PROMs) are objective metrics critical to evaluating outcomes throughout orthopedic surgery. New instruments continue to emerge, increasing the breadth of information required for those intending to use these measures for research or clinical care. Although earlier metrics were developed using the principles of classic test theory, newer instruments constructed using item response theory are amenable to computer-adaptive testing and may change the way these instruments are administered. This article aims to define the psychometric properties that are important to understand when using all PROMs and to review the most widely used instruments in sports medicine. Copyright © 2018 Elsevier Inc. All rights reserved.
Intercomparison of active and passive instruments for radon and radon progeny in North America
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, A.C.; Tu, Keng-Wu; Knutson, E.O.
1995-02-01
An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- andmore » beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within {plus_minus}10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement.« less
Improvements in Virtual Sensors: Using Spatial Information to Estimate Remote Sensing Spectra
NASA Technical Reports Server (NTRS)
Oza, Nikunj C.; Srivastava, Ashok N.; Stroeve, Julienne
2005-01-01
Various instruments are used to create images of the Earth and other objects in the universe in a diverse set of wavelength bands with the aim of understanding natural phenomena. Sometimes these instruments are built in a phased approach, with additional measurement capabilities added in later phases. In other cases, technology may mature to the point that the instrument offers new measurement capabilities that were not planned in the original design of the instrument. In still other cases, high resolution spectral measurements may be too costly to perform on a large sample and therefore lower resolution spectral instruments are used to take the majority of measurements. Many applied science questions that are relevant to the earth science remote sensing community require analysis of enormous amounts of data that were generated by instruments with disparate measurement capabilities. In past work [1], we addressed this problem using Virtual Sensors: a method that uses models trained on spectrally rich (high spectral resolution) data to "fill in" unmeasured spectral channels in spectrally poor (low spectral resolution) data. We demonstrated this method by using models trained on the high spectral resolution Terra MODIS instrument to estimate what the equivalent of the MODIS 1.6 micron channel would be for the NOAA AVHRR2 instrument. The scientific motivation for the simulation of the 1.6 micron channel is to improve the ability of the AVHRR2 sensor to detect clouds over snow and ice. This work contains preliminary experiments demonstrating that the use of spatial information can improve our ability to estimate these spectra.
The Electric Field and Waves Instruments on the Radiation Belt Storm Probes Mission
NASA Astrophysics Data System (ADS)
Wygant, J. R.; Bonnell, J. W.; Goetz, K.; Ergun, R. E.; Mozer, F. S.; Bale, S. D.; Ludlam, M.; Turin, P.; Harvey, P. R.; Hochmann, R.; Harps, K.; Dalton, G.; McCauley, J.; Rachelson, W.; Gordon, D.; Donakowski, B.; Shultz, C.; Smith, C.; Diaz-Aguado, M.; Fischer, J.; Heavner, S.; Berg, P.; Malsapina, D. M.; Bolton, M. K.; Hudson, M.; Strangeway, R. J.; Baker, D. N.; Li, X.; Albert, J.; Foster, J. C.; Chaston, C. C.; Mann, I.; Donovan, E.; Cully, C. M.; Cattell, C. A.; Krasnoselskikh, V.; Kersten, K.; Brenneman, A.; Tao, J. B.
2013-11-01
The Electric Fields and Waves (EFW) Instruments on the two Radiation Belt Storm Probe (RBSP) spacecraft (recently renamed the Van Allen Probes) are designed to measure three dimensional quasi-static and low frequency electric fields and waves associated with the major mechanisms responsible for the acceleration of energetic charged particles in the inner magnetosphere of the Earth. For this measurement, the instrument uses two pairs of spherical double probe sensors at the ends of orthogonal centripetally deployed booms in the spin plane with tip-to-tip separations of 100 meters. The third component of the electric field is measured by two spherical sensors separated by ˜15 m, deployed at the ends of two stacer booms oppositely directed along the spin axis of the spacecraft. The instrument provides a continuous stream of measurements over the entire orbit of the low frequency electric field vector at 32 samples/s in a survey mode. This survey mode also includes measurements of spacecraft potential to provide information on thermal electron plasma variations and structure. Survey mode spectral information allows the continuous evaluation of the peak value and spectral power in electric, magnetic and density fluctuations from several Hz to 6.5 kHz. On-board cross-spectral data allows the calculation of field-aligned wave Poynting flux along the magnetic field. For higher frequency waveform information, two different programmable burst memories are used with nominal sampling rates of 512 samples/s and 16 k samples/s. The EFW burst modes provide targeted measurements over brief time intervals of 3-d electric fields, 3-d wave magnetic fields (from the EMFISIS magnetic search coil sensors), and spacecraft potential. In the burst modes all six sensor-spacecraft potential measurements are telemetered enabling interferometric timing of small-scale plasma structures. In the first burst mode, the instrument stores all or a substantial fraction of the high frequency measurements in a 32 gigabyte burst memory. The sub-intervals to be downloaded are uplinked by ground command after inspection of instrument survey data and other information available on the ground. The second burst mode involves autonomous storing and playback of data controlled by flight software algorithms, which assess the "highest quality" events on the basis of instrument measurements and information from other instruments available on orbit. The EFW instrument provides 3-d wave electric field signals with a frequency response up to 400 kHz to the EMFISIS instrument for analysis and telemetry (Kletzing et al. Space Sci. Rev. 2013).
Trace Gas Retrievals from the GeoTASO Aircraft Instrument
NASA Astrophysics Data System (ADS)
Nowlan, C. R.; Liu, X.; Leitch, J. W.; Liu, C.; Gonzalez Abad, G.; Chance, K.; Cole, J.; Delker, T.; Good, W. S.; Murcray, F.; Ruppert, L.; Soo, D.; Loughner, C.; Follette-Cook, M. B.; Janz, S. J.; Kowalewski, M. G.; Pickering, K. E.; Zoogman, P.; Al-Saadi, J. A.
2015-12-01
The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument is a passive remote sensing instrument capable of making 2-D measurements of trace gases and aerosols from aircraft. The instrument measures backscattered UV and visible radiation, allowing the retrieval of trace gas amounts below the aircraft at horizontal resolutions on the order of 250 m x 250 m. GeoTASO was originally developed under NASA's Instrument Incubator Program as a test-bed instrument for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey mission, and is now also part of risk reduction for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) and Geostationary Environment Monitoring Spectrometer (GEMS) geostationary satellite missions. We present spatially resolved observations of ozone, nitrogen dioxide, formaldehyde and sulfur dioxide over urban areas and power plants from flights during the DISCOVER-AQ field campaigns in Texas and Colorado, as well as comparisons with observations made by ground-based Pandora spectrometers, in situ monitoring instruments and other aircraft instruments deployed during these campaigns. These measurements at various times of day are providing a very useful data set for testing and improving TEMPO and GEMS retrieval algorithms, as well as demonstrating prototype validation strategies.
NASA Astrophysics Data System (ADS)
van Aalderen-Smeets, Sandra; Walma van der Molen, Juliette
2013-03-01
In this article, we present a valid and reliable instrument which measures the attitude of in-service and pre-service primary teachers toward teaching science, called the Dimensions of Attitude Toward Science (DAS) Instrument. Attention to the attitudes of primary teachers toward teaching science is of fundamental importance to the professionalization of these teachers in the field of primary science education. With the development of this instrument, we sought to fulfill the need for a statistically and theoretically valid and reliable instrument to measure pre-service and in-service teachers' attitudes. The DAS Instrument is based on a comprehensive theoretical framework for attitude toward (teaching) science. After pilot testing, the DAS was revised and subsequently validated using a large group of respondents (pre-service and in-service primary teachers) (N = 556). The theoretical underpinning of the DAS combined with the statistical data indicate that the DAS possesses good construct validity and that it proves to be a promising instrument that can be utilized for research purposes, and also as a teacher training and coaching tool. This instrument can therefore make a valuable contribution to progress within the field of science education.
Slater, Paul; McCormack, Brendan; Bunting, Brendan
2009-01-01
Evidence shows that adopting a person-centered approach to nursing alters the work environment, reduces anxiety levels among nurses in the long term, promotes teamwork among staff, and increases job satisfaction. However, few studies have attempted to quantify the outcomes from the adoption of person-centered nursing. The lack of outcome measurement is in part influenced by the lack of a standardized instrument to measure person-centered nursing. The aim of this study was to develop an instrument (the Nursing Context Index) to inform the development of person-centered nursing and outcomes arising. The Nursing Context Index (NCI) was developed through three stages. Stage 1 involved a systematic literature review to identify the key characteristics that needed to be considered in the instrument. Stage 2 involved the identification and selection of items for inclusion in the instrument identified through focus group discussions. A 19-construct instrument was developed. Face validity and content validity were gauged. In Stage 3, a pilot study (n = 23) was conducted to test the instrument. Measures of internal consistency were ensured using Cronbach's alpha. Criterion-related validity of the instrument was ensured through comparison between factors contained in the instrument. Findings show that the NCI is an accurate representation of the factors influenced by a clinical setting's progression to person-centered nursing. The factors were deemed appropriate to the clinical settings, and possessed face and content validity. Initial statistical findings confirm the validity and usability of the NCI. The process used for the development and testing of the instrument was found to be effective. The NCI was deemed to be an effective measure of factors influenced by the implementation of person-centered nursing and would help in redressing a scarcity of quantitative evidence to examine the benefits of nurses working in a person-centered manner.
Prinsen, Cecilia A C; Vohra, Sunita; Rose, Michael R; King-Jones, Susanne; Ishaque, Sana; Bhaloo, Zafira; Adams, Denise; Terwee, Caroline B
2014-06-25
The Core Outcome Measures in Effectiveness Trials (COMET) initiative aims to facilitate the development and application of 'core outcome sets' (COS). A COS is an agreed minimum set of outcomes that should be measured and reported in all clinical trials of a specific disease or trial population. The overall aim of the Core Outcome Measurement Instrument Selection (COMIS) project is to develop a guideline on how to select outcome measurement instruments for outcomes included in a COS. As part of this project, we describe our current efforts to achieve a consensus on the methods for selecting outcome measurement instruments for outcomes to be included in a COS. A Delphi study is being performed by a panel of international experts representing diverse stakeholders with the intention that this will result in a guideline for outcome measurement instrument selection. Informed by a literature review, a Delphi questionnaire was developed to identify potentially relevant tasks on instrument selection. The Delphi study takes place in a series of rounds. In the first round, panelists were asked to rate the importance of different tasks in the selection of outcome measurement instruments. They were encouraged to justify their choices and to add other relevant tasks. Consensus was reached if at least 70% of the panelists considered a task 'highly recommended' or 'desirable' and if no opposing arguments were provided. These tasks will be included in the guideline. Tasks that at least 50% of the panelists considered 'not relevant' will be excluded from the guideline. Tasks that were indeterminate will be taken to the second round. All responses of the first round are currently being aggregated and will be fed back to panelists in the second round. A third round will only be performed if the results of the second round require it. Since the Delphi method allows a large group of international experts to participate, we consider it to be the preferred consensus-based method for our study. Based upon this consultation process, a guideline will be developed on instrument selection for outcomes to be included in a COS.
Individual Entrepreneurial Orientation: Development of a Measurement Instrument
ERIC Educational Resources Information Center
Bolton, Dawn Langkamp; Lane, Michelle D.
2012-01-01
Purpose: The purpose of this paper is to develop a measurement instrument for individual entrepreneurial orientation to be used to measure the entrepreneurial orientation of students and other individuals. Design/methodology/approach: A measure of Individual Entrepreneurial Orientation (IEO) was generated, validated, and then tested on 1,100…
Measuring School Climate: An Overview of Measurement Scales
ERIC Educational Resources Information Center
Kohl, Diane; Recchia, Sophie; Steffgen, Georges
2013-01-01
Background: School climate is a heterogeneous concept with a multitude of standardised and validated instruments available to measure it. Purpose: This overview of measurement scales aims to provide researchers with short summaries of some of the self-report instruments in existence, especially in relation to the link between school climate and…
27 CFR 19.188 - Measuring devices and proofing instruments.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Measuring devices and proofing instruments. 19.188 Section 19.188 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX..., and Security Requirements Measuring and Proofing Equipment Requirements § 19.188 Measuring devices and...
27 CFR 19.188 - Measuring devices and proofing instruments.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Measuring devices and proofing instruments. 19.188 Section 19.188 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX..., and Security Requirements Measuring and Proofing Equipment Requirements § 19.188 Measuring devices and...
27 CFR 19.188 - Measuring devices and proofing instruments.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Measuring devices and proofing instruments. 19.188 Section 19.188 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX..., and Security Requirements Measuring and Proofing Equipment Requirements § 19.188 Measuring devices and...
27 CFR 19.188 - Measuring devices and proofing instruments.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Measuring devices and proofing instruments. 19.188 Section 19.188 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX..., and Security Requirements Measuring and Proofing Equipment Requirements § 19.188 Measuring devices and...
Bouwmans, Clazien; Krol, Marieke; Severens, Hans; Koopmanschap, Marc; Brouwer, Werner; Hakkaart-van Roijen, Leona
2015-09-01
Productivity losses often contribute significantly to the total costs in economic evaluations adopting a societal perspective. Currently, no consensus exists on the measurement and valuation of productivity losses. We aimed to develop a standardized instrument for measuring and valuing productivity losses. A group of researchers with extensive experience in measuring and valuing productivity losses designed an instrument suitable for self-completion, building on preknowledge and evidence on validity. The instrument was designed to cover all domains of productivity losses, thus allowing quantification and valuation of all productivity losses. A feasibility study was performed to check the questionnaire's consistency and intelligibility. The iMTA Productivity Cost Questionnaire (iPCQ) includes three modules measuring productivity losses of paid work due to 1) absenteeism and 2) presenteeism and productivity losses related to 3) unpaid work. Questions for measuring absenteeism and presenteeism were derived from existing validated questionnaires. Because validated measures of losses of unpaid work are scarce, the questions of this module were newly developed. To enhance the instrument's feasibility, simple language was used. The feasibility study included 195 respondents (response rate 80%) older than 18 years. Seven percent (n = 13) identified problems while filling in the iPCQ, including problems with the questionnaire's instructions and routing (n = 6) and wording (n = 2). Five respondents experienced difficulties in estimating the time that would be needed for other people to make up for lost unpaid work. Most modules of the iPCQ are based on validated questions derived from previously available instruments. The instrument is understandable for most of the general public. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Irwanto, Rohaeti, Eli; LFX, Endang Widjajanti; Suyanta
2017-05-01
This research aims to develop instrument and determine the characteristics of an integrated assessment instrument. This research uses 4-D model, which includes define, design, develop, and disseminate. The primary product is validated by expert judgment, tested it's readability by students, and assessed it's feasibility by chemistry teachers. This research involved 246 students of grade XI of four senior high schools in Yogyakarta, Indonesia. Data collection techniques include interview, questionnaire, and test. Data collection instruments include interview guideline, item validation sheet, users' response questionnaire, instrument readability questionnaire, and essay test. The results show that the integrated assessment instrument has Aiken validity value of 0.95. Item reliability was 0.99 and person reliability was 0.69. Teachers' response to the integrated assessment instrument is very good. Therefore, the integrated assessment instrument is feasible to be applied to measure the students' analytical thinking and science process skills.
Heinemann, Allen W; Miskovic, Ana; Semik, Patrick; Wong, Alex; Dashner, Jessica; Baum, Carolyn; Magasi, Susan; Hammel, Joy; Tulsky, David S; Garcia, Sofia F; Jerousek, Sara; Lai, Jin-Shei; Carlozzi, Noelle E; Gray, David B
2016-12-01
To describe the unique and overlapping content of the newly developed Environmental Factors Item Banks (EFIB) and 7 legacy environmental factor instruments, and to evaluate the EFIB's construct validity by examining associations with legacy instruments. Cross-sectional, observational cohort. Community. A sample of community-dwelling adults with stroke, spinal cord injury, and traumatic brain injury (N=568). None. EFIB covering domains of the built and natural environment; systems, services, and policies; social environment; and access to information and technology; the Craig Hospital Inventory of Environmental Factors (CHIEF) short form; the Facilitators and Barriers Survey/Mobility (FABS/M) short form; the Home and Community Environment Instrument (HACE); the Measure of the Quality of the Environment (MQE) short form; and 3 of the Patient Reported Outcomes Measurement Information System's (PROMIS) Quality of Social Support measures. The EFIB and legacy instruments assess most of the International Classification of Functioning, Disability and Health (ICF) environmental factors chapters, including chapter 1 (products and technology; 75 items corresponding to 11 codes), chapter 2 (natural environment and human-made changes; 31 items corresponding to 7 codes), chapter 3 (support and relationships; 74 items corresponding to 7 codes), chapter 4 (attitudes; 83 items corresponding to 8 codes), and chapter 5 (services, systems, and policies; 72 items corresponding to 16 codes). Construct validity is provided by moderate correlations between EFIB measures and the CHIEF, MQE barriers, HACE technology mobility, FABS/M community built features, and PROMIS item banks and by small correlations with other legacy instruments. Only 5 of the 66 legacy instrument correlation coefficients are moderate, suggesting they measure unique aspects of the environment, whereas all intra-EFIB correlations were at least moderate. The EFIB measures provide a brief and focused assessment of ICF environmental factor chapters. The pattern of correlations with legacy instruments provides initial evidence of construct validity. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Makai, Peter; Brouwer, Werner B F; Koopmanschap, Marc A; Stolk, Elly A; Nieboer, Anna P
2014-02-01
Gaining health may not be the main goal of healthcare services aimed at older people, which may (also) seek to improve wellbeing. This emphasizes the need of finding appropriate outcome measures for economic evaluation of such services, particularly in long-term care, capturing more than only health-related quality of life (HrQol). This review assesses the usefulness of HrQol and wellbeing instruments for economic evaluations specifically aimed at older people, focusing on generic and preference-based questionnaires measuring wellbeing in particular. We systematically searched six databases and extracted instruments used to assess HrQol and wellbeing outcomes. Instruments were compared based on their usefulness for economic evaluation of services aimed at older people (dimensions measured, availability of utility scores, extent of validation). We identified 487 articles using 34 generic instruments: 22 wellbeing (two of which were preference-based) and 11 HrQol instruments. While standard HrQol instruments measure physical, social and psychological dimensions, wellbeing instruments contain additional dimensions such as purpose in life and achievement, security, and freedom. We found four promising wellbeing instruments for inclusion in economic evaluation: Ferrans and Powers QLI and the WHO-Qol OLD, ICECAP-O and the ASCOT. Ferrans and Powers QLI and the WHO-Qol OLD are widely validated but lack preference-weights while for ICECAP-O and the ASCOT preference-weights are available, but are less widely validated. Until preference-weights are available for the first two instruments, the ICECAP-O and the ASCOT currently appear to be the most useful instruments for economic evaluations in services aimed at older people. Their limitations are that (1) health dimensions may be captured only partially and (2) the instruments require further validation. Therefore, we currently recommend using the ICECAP-O or the ASCOT alongside the EQ-5D or SF-6D when evaluating interventions aimed at older people. Copyright © 2013 Elsevier Ltd. All rights reserved.
21 CFR 862.2570 - Instrumentation for clinical multiplex test systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Instrumentation for clinical multiplex test... Laboratory Instruments § 862.2570 Instrumentation for clinical multiplex test systems. (a) Identification. Instrumentation for clinical multiplex test systems is a device intended to measure and sort multiple signals...
21 CFR 862.2570 - Instrumentation for clinical multiplex test systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Instrumentation for clinical multiplex test... Laboratory Instruments § 862.2570 Instrumentation for clinical multiplex test systems. (a) Identification. Instrumentation for clinical multiplex test systems is a device intended to measure and sort multiple signals...
21 CFR 862.2570 - Instrumentation for clinical multiplex test systems.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Instrumentation for clinical multiplex test... Laboratory Instruments § 862.2570 Instrumentation for clinical multiplex test systems. (a) Identification. Instrumentation for clinical multiplex test systems is a device intended to measure and sort multiple signals...
21 CFR 862.2570 - Instrumentation for clinical multiplex test systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Instrumentation for clinical multiplex test... Laboratory Instruments § 862.2570 Instrumentation for clinical multiplex test systems. (a) Identification. Instrumentation for clinical multiplex test systems is a device intended to measure and sort multiple signals...
Brandão, Tânia; Tavares, Rita; Schulz, Marc S; Matos, Paula Mena
2016-02-01
The important role of emotion regulation and expression in adaptation to breast cancer is now widely recognized. Studies have shown that optimal emotion regulation strategies, including less constrained emotional expression, are associated with better adaptation. Our objective was to systematically review measures used to assess the way women with breast cancer regulate their emotions. This systematic review was conducted in accordance with PRISMA guidelines. Nine different databases were searched. Data were independently extracted and assessed by two researchers. English-language articles that used at least one instrument to measure strategies to regulate emotions in women with breast cancer were included. Of 679 abstracts identified 59 studies were deemed eligible for inclusion. Studies were coded regarding their objectives, methods, and results. We identified 16 instruments used to measure strategies of emotion regulation and expression. The most frequently employed instrument was the Courtauld Emotional Control Scale. Few psychometric proprieties other than internal consistency were reported for most instruments. Many studies did not include important information regarding descriptive characteristics and psychometric properties of the instruments used. The instruments used tap different aspects of emotion regulation. Specific instruments should be explored further with regard to content, validity, and reliability in the context of breast cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.
Push Tester For Laminated Films
NASA Technical Reports Server (NTRS)
Sugimura, Russell S.
1991-01-01
Small instrument used to measure brittleness of polymer film adhesively bonded to hard substrate. Penlike instrument has microball tip. Small pointer in slot on side of instrument used to calibrate and indicate spring force applied by point. Microball dents only small area of specimen. Such measurements used to measure rates of embrittlement in environmental tests of candidate laminated-film covers for photovoltaic modules. Not limited to transparent films; also used on opaque laminated films on back panels of photovoltaic modules.
Cross Section Measurements Using the Zero Degree Detector
NASA Technical Reports Server (NTRS)
Christl, M. J.; Adams, J. H., Jr.; Heilbronn, L.; Kuznetsov, E. N.; Miller, J.; Zeitlin, C.
2007-01-01
The Zero Degree Detector (ZDD) is an instrument that has been used in accelerator exposures to measure the angular dependence of particles produced in heavy ion fragmentation experiments. The ZDD uses two identical layers of pixelated silicon detectors that make coincident measurements over the active area of the instrument. The angular distribution of secondary particle produced in nuclear interactions for several heavy ions: and target materials will be presented along with performance characteristic of the instrument.
NASA Technical Reports Server (NTRS)
Chirivella, J. E.
1975-01-01
Instrumentation for the measurement of plume exhaust specie deposition rates were developed and demonstrated. The instruments, two sets of quartz crystal microbalances, were designed for low temperature operation in the back flow and variable temperature operation in the core flow regions of an exhaust plume. These quartz crystal microbalances performed nominally, and measurements of exhaust specie deposition rates for 8400 number of pulses for a 0.1-lb monopropellant thruster are reported.
Dimensional nanometrology at the National Physical Laboratory
NASA Astrophysics Data System (ADS)
Yacoot, Andrew; Leach, Richard; Hughes, Ben; Giusca, Claudiu; Jones, Christopher; Wilson, Alan
2008-10-01
The growth in nanotechnology has led to an increased requirement for traceable dimensional measurements of nanometre-sized objects and micrometre-sized objects with nanometre tolerances. To meet this challenge NPL has developed both purpose built instrumentation and added metrology to commercially available equipment. This paper describes the development and use of a selection of these instruments that include: atomic force microscopy, x-ray interferometry, a low force balance, a micro coordinate measuring machine and an areal surface texture measuring instrument.
Scoping review of instruments measuring attitudes toward disability.
Palad, Yves Y; Barquia, Rensyl B; Domingo, Harvey C; Flores, Clinton K; Padilla, Levin I; Ramel, Jonas Mikko D
2016-07-01
Negative attitudes toward disability cause difficulties in integrating persons with disabilities (PWDs) into society and limit their access to health care, education, employment, and leisure. Being aware of societal attitudes toward disability may help explain discrimination against PWDs and draw attention to the solutions needed to address these. Good measures of attitudes are vital for this purpose. The aim is to synthesize published information, including evidences on psychometric properties and overall utility on instruments that measure attitudes toward disability. A two-tiered search process was performed to identify instruments that measure attitudes toward disability and retrieve articles that describe their development and/or validation. The CanChild Outcome Measures Rating Form was utilized to determine the overall utility of the instruments. Results were synthesized using a self-constructed data extraction form. Thirty-one instruments were included in the study. Five measured attitudes toward communication disability, 7 toward intellectual disability, 4 toward mental illness, and 15 toward disability in general. Target respondents ranged from children to adults, and included respondents from different occupations and cultural backgrounds. Twenty-three were found to have adequate overall utility, while 8 have poor overall utility. Several instruments are available in literature and all may be used for their intended purposes as long as their limitations are considered. Many still require further validation to ascertain their validity and responsiveness to change. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Menold, Natalja; Raykov, Tenko
2016-01-01
This article examines the possible dependency of composite reliability on presentation format of the elements of a multi-item measuring instrument. Using empirical data and a recent method for interval estimation of group differences in reliability, we demonstrate that the reliability of an instrument need not be the same when polarity of the…
ERIC Educational Resources Information Center
Lane, Dennis Glenn
2017-01-01
The goal of this study was to develop a survey instrument to measure transactional distance in secondary blended learning environments. This study resulted in a 35-item survey instrument, the Blended Learning Assessment Scale of Transactional Distance (BLASTD), which was tested using a convenience sample of secondary students (n = 222) at a…
ERIC Educational Resources Information Center
Tanujaya, Benidiktus
2016-01-01
The purpose of this research was to develop an instrument that can be used to measure higher-order thinking skills (HOTS) in mathematics instruction of high school students. This research was conducted using a standard procedure of instrument development, from the development of conceptual definitions, development of operational definitions,…
ERIC Educational Resources Information Center
Bowen, Craig W.
1999-01-01
Reports the development and score validation of an instrument for measuring anxieties students experience in college chemistry laboratories. Factor analysis of scores from 361 college students shows that the developed Chemistry Laboratory Anxiety Instrument measures five constructs. Results from a second sample of 598 students show that scores on…
The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument is a test bed for upcoming air quality satellite instruments that will measure backscattered ultraviolet, visible and near-infrared light from geostationary orbit. GeoTASO flew on the NASA F...
ERIC Educational Resources Information Center
van Aalderen-Smeets, Sandra; Walma van der Molen, Juliette
2013-01-01
In this article, we present a valid and reliable instrument which measures the attitude of in-service and pre-service primary teachers toward teaching science, called the Dimensions of Attitude Toward Science (DAS) Instrument. Attention to the attitudes of primary teachers toward teaching science is of fundamental importance to the…
A laser tracking dynamic robot metrology instrument
NASA Technical Reports Server (NTRS)
Parker, G. A.; Mayer, J. R. R.
1989-01-01
Research work over several years has resulted in the development of a laser tracking instrument capable of dynamic 3-D measurements of robot end-effector trajectories. The instrument characteristics and experiments to measure the static and dynamic performance of a robot in an industrial manufacturing environment are described. The use of this technology for space applications is examined.
An Analysis of Several Instruments Measuring "Nature of Science" Objectives
ERIC Educational Resources Information Center
Doran, Rodney L.; And Others
1974-01-01
Reported is an investigation of the relationship among three selected instruments based on the responses of a sample of high school students. The instruments were the Nature of Science Scale (NOSS), the Science Support Scale (SSS), and the Test on the Social Aspects of Science (TSAS). All purport to measure "nature of science"…
ERIC Educational Resources Information Center
DeChenne, Sue Ellen; Enochs, Larry
2010-01-01
An instrument to measure the teaching self-efficacy of science, technology, engineering, and mathematics (STEM) GTAs is adapted from a general college teaching instrument (Prieto Navarro, 2005) for the specific teaching environment of the STEM GTAs. The construct and content validity and reliability of the final instrument are indicated. The final…
ERIC Educational Resources Information Center
Carey, John; Brigman, Greg; Webb, Linda; Villares, Elizabeth; Harrington, Karen
2014-01-01
This article describes the development of the Student Engagement in School Success Skills instrument including item development and exploratory factor analysis. The instrument was developed to measure student use of the skills and strategies identified as most critical for long-term school success that are typically taught by school counselors.
ERIC Educational Resources Information Center
Idris, Khairiani; Yang, Kai-Lin
2017-01-01
This article reports the results of a mixed-methods approach to develop and validate an instrument to measure Indonesian pre-service teachers' conceptions of statistics. First, a phenomenographic study involving a sample of 44 participants uncovered six categories of conceptions of statistics. Second, an instrument of conceptions of statistics was…
The Radio & Plasma Wave Investigation (RPWI) for JUICE - Instrument Concept and Capabilities
NASA Astrophysics Data System (ADS)
Bergman, J. E. S.
2013-09-01
We present the concept and capabilities of the Radio & Plasma Waves Investigation (RPWI) instrument for the JUICE mission. The RPWI instrument provides measurements of plasma, electric- and magnetic field fluctuations from near DC up to 45 MHz. The RPWI sensors are four Langmuir probes for low temperature plasma diagnostics and electric field measurements, a three-axis searchcoil magnetometer for low-frequency magnetic field measurements, and a three-axial radio antenna, which operates from 80 kHz up to 45 MHz and thus gives RPWI remote sensing capabilities.. In addition, active mutual impedance measurements are used to diagnose the in situ plasma. The RPWI instrument is unique as it provides vector field measurements in the whole frequency range. This makes it possible to employ advanced diagnostics techniques, which are unavailable for scalar measurements. The RPWI instrument has thus outstanding new capabilities not previously available to outer planet missions, which and enables RPWI to address many fundamental planetary science objectives, such as the electrodynamic influence of the Jovian magnetosphere on the exospheres, surfaces and conducting oceans of Ganymede, Europa, and Callisto. RPWI will also be able to investigate the sources of radio emissions from auroral regions of Ganymede and Jupiter, in detail and with unprecedented sensitivity, and possibly also lightning. Moreover, RPWI can search for exhaust plumes from cracks on the icy moons, as well as μm-sized dust and related dust-plasmasurface interaction processes occurring near the icy moons of Jupiter. The top-level blockdiagram of the RPWI instrument is shown here. A detailed technical description of the RPWI instrument will be given.
Enhancing our Understanding of Snowfall Modes with Ground-Based Observations
NASA Astrophysics Data System (ADS)
Pettersen, C.; Kulie, M.; Petersen, W. A.; Bliven, L. F.; Wood, N.
2016-12-01
Snowfall can be broadly categorized into deep and shallow events based on the vertical distribution of the precipitating ice. Remotely sensed data refine these precipitation categories and aid in discerning the underlying macro- and microphysical mechanisms. The unique patterns in the remotely sensed instruments observations can potentially connect distinct modes of snowfall to specific processes. Though satellites can observe and recognize these patterns in snowfall, these measurements are limited - particularly in cases of shallow and light precipitation, as the snow may be too close to the surface or below the detection limits of the instrumentation. By enhancing satellite measurements with ground-based instrumentation, whether with limited-term field campaigns or long-term strategic sites, we can further our understanding and assumptions about different snowfall modes and how they are measured from spaceborne instruments. Presented are three years of data from a ground-based instrument suite consisting of a MicroRain Radar (MRR; optimized for snow events) and a Precipitation Imaging Package (PIP). These instruments are located at the Marquette, Michigan National Weather Service Weather Forecast Office to: a) use coincident meteorological measurements and observations to enhance our understanding of the thermodynamic drivers and b) showcase these instruments in an operational setting to enhance forecasts of shallow snow events. Three winters of MRR and PIP measurements are partitioned, based on meteorological surface observations, into two-dimensional histograms of reflectivity and particle size distribution data. These statistics improve our interpretation of deep versus shallow precipitation. Additionally, these statistical techniques are applied to similar datasets from Global Precipitation Measurement field campaigns for further insight into cloud and precipitation macro- and microphysical processes.
Ozone determinations with the NOAA SBUV/2 system
NASA Technical Reports Server (NTRS)
Planet, Walter G.; Lienesch, James H.; Bowman, Harold D.; Miller, Alvin J.; Nagatani, Ronald M.
1994-01-01
The NOAA satellite ozone monitoring program was initiated by the National Environmental Satellite Data and Information Service (NESDIS) in December 1984, with the launch of the NOAA-9 spacecraft carrying the first operational Solar Backscatter Ultraviolet Spectrometer (SBUV/2). This instrument and its successor on NOAA-11, launched in 1988, are similar to the SBUV instrument launched by the NASA in 1978 on the Nimbus-7 research spacecraft. Measurements by the SBUV and SBUV/2 instruments overlap beginning in 1985. These instruments use measurements of the reflected ultraviolet solar radiation from the atmosphere to derive total ozone amounts and ozone vertical profiles. Since launch, the NOAA instruments and the derived products have been undergoing extensive evaluation by scientists of NOAA and NASA. Measurements obtained with these instruments are processed in real time by the NESDIS. These are reprocessed as the SBUV/2 instrument characterization is refined and as the retrieval algorithm for processing the data is improved. The NOAA-9 ozone data archive begins in March 1985 and continues through October 1990. The archive of NOAA-11 data begins in January 1989 and the data continues to be acquired in 1992.
[Development of a questionnaire to measure family stress among married working women].
Kim, Gwang Suk; Cho, Won Jung
2006-08-01
Even though a number of studies have suggested that appropriate measuring instruments of family stress for working women have to be developed, the validity and reliability of the instruments used have not been consistently examined. The purpose of the present study was to develop a sensitive instrument to measure family stress for married working women, and to test the validity and reliability of the instrument. The items generated for this instrument were drawn from a comprehensive literature review. Twenty four items were developed through evaluation by 10 experts and twenty one items were finally confirmed through item analysis. Psychometric testing was preformed and confirmed with a convenient sample of 240 women employed in the industrial sector. Four factors evolved by factor analysis, which explained 50.5% of the total variance. The first factor 'Cooperation' explained 28.1%, 2nd factor 'Satisfaction with relationships' 10.6%, 3rd factor 'Democratic and comfortable environment' 6.3%, and 4th factor 'Disturbance of own living' 5.5%. Cronbach's coefficient of this instrument was 0.86. The study supports the validity and reliability of the instrument.
Measurement Properties of Instruments for Measuring of Lymphedema: Systematic Review.
Hidding, Janine T; Viehoff, Peter B; Beurskens, Carien H G; van Laarhoven, Hanneke W M; Nijhuis-van der Sanden, Maria W G; van der Wees, Philip J
2016-12-01
Lymphedema is a common complication of cancer treatment, resulting in swelling and subjective symptoms. Reliable and valid measurement of this side effect of medical treatment is important. The purpose of this study was to provide best evidence regarding which measurement instruments are most appropriate in measuring lymphedema in its different stages. The PubMed and Web of Science databases were used, and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. Clinical studies on measurement instruments assessing lymphedema were reviewed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) scoring instrument for quality assessment. Data on reliability, concurrent validity, convergent validity, sensitivity, specificity, applicability, and costs were extracted. Pooled data showed good intrarater intraclass correlation coefficients (ICCs) (.89) for bioimpedance spectroscopy (BIS) in the lower extremities and high intrarater and interrater ICCs for water volumetry, tape measurement, and perometry (.98-.99) in the upper extremities. In the upper extremities, the standard error of measurement was 3.6% (σ=0.7%) for water volumetry, 5.6% (σ=2.1%) for perometry, and 6.6% (σ=2.6%) for tape measurement. Sensitivity of tape measurement in the upper extremities, using different cutoff points, varied from 0.73 to 0.90, and specificity values varied from 0.72 to 0.78. No uniform definition of lymphedema was available, and a gold standard as a reference test was lacking. Items concerning risk of bias were study design, patient selection, description of lymphedema, blinding of test outcomes, and number of included participants. Measurement instruments with evidence for good reliability and validity were BIS, water volumetry, tape measurement, and perometry, where BIS can detect alterations in extracellular fluid in stage 1 lymphedema and the other measurement instruments can detect alterations in volume starting from stage 2. In research, water volumetry is indicated as a reference test for measuring lymphedema in the upper extremities. © 2016 American Physical Therapy Association.
The design of optimum remote-sensing instruments
NASA Technical Reports Server (NTRS)
Peckham, G. E.; Flower, D. A.
1983-01-01
Remote-sensing instruments allow values for certain properties of a target to be retrieved from measurements of radiation emitted, reflected or transmitted by the target. The retrieval accuracy is affected by random variations in the many target properties which affect the measurements. A method is described, by which statistical properties of the target and theoretical models of its electromagnetic behavior can be used to choose values for the instrument parameters which maximize the retrieval accuracy. The technique is applicable to a wide range of remote-sensing instruments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anaya, O.; Moreno, G.E.L.; Madrigal, M.M.
1999-11-01
In the last years, several definitions of power have been proposed for more accurate measurement of electrical quantities in presence of harmonics pollution on power lines. Nevertheless, only few instruments have been constructed considering these definitions. This paper describes a new microcontroller-based digital instrument, which include definitions based on Harley Transform. The algorithms are fully processed using Fast Hartley Transform (FHT) and 16 bit-microcontroller platform. The constructed prototype was compared with commercial harmonics analyzer instrument.
NASA Astrophysics Data System (ADS)
Hoeksema, J. T.; Baldner, C. S.; Bush, R. I.; Schou, J.; Scherrer, P. H.
2018-03-01
The Helioseismic and Magnetic Imager (HMI) instrument is a major component of NASA's Solar Dynamics Observatory (SDO) spacecraft. Since commencement of full regular science operations on 1 May 2010, HMI has operated with remarkable continuity, e.g. during the more than five years of the SDO prime mission that ended 30 September 2015, HMI collected 98.4% of all possible 45-second velocity maps; minimizing gaps in these full-disk Dopplergrams is crucial for helioseismology. HMI velocity, intensity, and magnetic-field measurements are used in numerous investigations, so understanding the quality of the data is important. This article describes the calibration measurements used to track the performance of the HMI instrument, and it details trends in important instrument parameters during the prime mission. Regular calibration sequences provide information used to improve and update the calibration of HMI data. The set-point temperature of the instrument front window and optical bench is adjusted regularly to maintain instrument focus, and changes in the temperature-control scheme have been made to improve stability in the observable quantities. The exposure time has been changed to compensate for a 20% decrease in instrument throughput. Measurements of the performance of the shutter and tuning mechanisms show that they are aging as expected and continue to perform according to specification. Parameters of the tunable optical-filter elements are regularly adjusted to account for drifts in the central wavelength. Frequent measurements of changing CCD-camera characteristics, such as gain and flat field, are used to calibrate the observations. Infrequent expected events such as eclipses, transits, and spacecraft off-points interrupt regular instrument operations and provide the opportunity to perform additional calibration. Onboard instrument anomalies are rare and seem to occur quite uniformly in time. The instrument continues to perform very well.
Semi-empirical and phenomenological instrument functions for the scanning tunneling microscope
NASA Astrophysics Data System (ADS)
Feuchtwang, T. E.; Cutler, P. H.; Notea, A.
1988-08-01
Recent progress in the development of a convenient algorithm for the determination of a quantitative local density of states (LDOS) of the sample, from data measured in the STM, is reviewd. It is argued that the sample LDOS strikes a good balance between the information content of a surface characteristic and effort required to obtain it experimentally. Hence, procedures to determine the sample LDOS as directly and as tip-model independently as possible are emphasized. The solution of the STM's "inverse" problem in terms of novel versions of the instrument (or Green) function technique is considered in preference to the well known, more direct solutions. Two types of instrument functions are considered: Approximations of the basic tip-instrument function obtained from the transfer Hamiltonian theory of the STM-STS. And, phenomenological instrument functions devised as a systematic scheme for semi-empirical first order corrections of "ideal" models. The instrument function, in this case, describes the corrections as the response of an independent component of the measuring apparatus inserted between the "ideal" instrument and the measured data. This linear response theory of measurement is reviewed and applied. A procedure for the estimation of the consistency of the model and the systematic errors due to the use of an approximate instrument function is presented. The independence of the instrument function techniques from explicit microscopic models of the tip is noted. The need for semi-empirical, as opposed to strictly empirical or analytical determination of the instrument function is discussed. The extension of the theory to the scanning tunneling spectrometer is noted, as well as its use in a theory of resolution.
Maratia, Stefano; Cedillo, Sergio; Rejas, Javier
2016-10-01
The objective was to obtain a standardized evaluation of available specific and generic breast cancer health-related quality-of-life instruments. We carried out systematic literature reviews in the PubMed and EMBASE databases to identify manuscripts which contained information regarding either the development process or metric properties of health-related quality-of-life instruments used among breast cancer patients. Each instrument was evaluated independently by two researchers, and occasionally a third one, using the Evaluating Measures of Patient-Reported Outcomes (EMPRO) tool. An overall score and seven attribute-specific EMPRO scores were calculated (range 0-100, worst to best): concept and measurement model, reliability, validity, responsiveness, interpretability, burden, and alternative forms. FACT-B was the instrument with the best global performance, obtaining an overall EMPRO score of 79.27. It was also the most accurate instrument on the Concept and Measurement Model, Reliability, and Interpretability attributes. Four more instruments scored over 50 points on the overall score, which summarizes the five attribute-specific scores: EORTC BR-23, IBCSG, WHO-QOL BREF, and SF-36. An overall score of at least 50 points implies that the use of these instruments could be recommended for assessing health-related quality of life in breast cancer patients. The FACT-B scored the highest on overall on our EMPRO evaluation of instruments measuring health-related quality of life among breast cancer patients. However, depending on the purpose of the study, several instruments (EORTC BR-23, IBCSG, SF-36, and WHO-QOL BREF) have shown good performance in some of the specific individual dimensions included in the EMPRO.
Christodoulou, Asterios; Mikrogeorgis, Georgios; Vouzara, Triantafillia; Papachristou, Konstantinos; Angelopoulos, Christos; Nikolaidis, Nikolaos; Pitas, Ioannis; Lyroudia, Kleoniki
2018-02-15
In this study, the three-dimensional (3D) modification of root canal curvature was measured, after the application of Reciproc instrumentation technique, by using cone beam computed tomography (CBCT) imaging and a special algorithm developed for the 3D measurement of the curvature of the root canal. Thirty extracted upper molars were selected. Digital radiographs for each tooth were taken. Root curvature was measured by using Schneider method and they were divided into three groups, each one consisting of 10 roots, according to their curvature: Group 1 (0°-20°), Group 2 (21°-40°), Group 3 (41°-60°). CBCT imaging was applied to each tooth before and after its instrumentation, and the data were examined by using a specially developed CBCT image analysis algorithm. The instrumentation with Reciproc led to a decrease of the curvature by 30.23% (on average) in all groups. The proposed methodology proved to be able to measure the curvature of the root canal and its 3D modification after the instrumentation.
Compact Instruments Measure Helium-Leak Rates
NASA Technical Reports Server (NTRS)
Stout, Stephen; Immer, Christopher
2003-01-01
Compact, lightweight instruments have been developed for measuring small flows of helium and/or detecting helium leaks in solenoid valves when the valves are nominally closed. These instruments do not impede the flows when the valves are nominally open. They can be integrated into newly fabricated valves or retrofitted to previously fabricated valves. Each instrument includes an upstream and a downstream thermistor separated by a heater, plus associated analog and digital heater-control, signal- conditioning, and data-processing circuits. The thermistors and heater are off-the-shelf surface mount components mounted on a circuit board in the flow path. The operation of the instrument is based on a well-established thermal mass-flow-measurement technique: Convection by the flow that one seeks to measure gives rise to transfer of heat from the heater to the downstream thermistor. The temperature difference measured by the thermistors is directly related to the rate of flow. The calibration curve from temperature gradient to helium flow is closely approximated via fifth-order polynomial. A microprocessor that is part of the electronic circuitry implements the calibration curve to compute the flow rate from the thermistor readings.
Cabrera-Arana, Gustavo A; Londoño-Pimienta, Jaime L; Bello-Parías, León D
2008-01-01
Validating an instrument for measuring the perceived quality of services received by people using hospitals forming part of the Colombian Ministry of Social Protection's restructuring, redesigning and modernisation programme for health-service providing networks. Sánchez and Echeverri's guidelines for validating health quality measurement scales were followed due to the lack of a valid instrument for doing this in Colombia. Conceptual synthesis led to identifying a structure of constituent indicators, domains and sub-domains regarding the perception of health service quality. A list of reactions (having a scale for categorising the replies) was analysed according to the validity of appearance, construct, criteria and utility as criteria for sensitivity and usefulness. Successive revisions and three rounds of field-trials led to producing PECASUSS, an acronym given to the instrument for measuring users' perception of health service quality (Percepción de Calidad Según Usuarios de Servicios de Salud). The guidelines effectively orientated the validation of the instrument required for measuring the perceived quality of health services received by people using hospitals forming part of the programme.
Quantifying measurement uncertainty and spatial variability in the context of model evaluation
NASA Astrophysics Data System (ADS)
Choukulkar, A.; Brewer, A.; Pichugina, Y. L.; Bonin, T.; Banta, R. M.; Sandberg, S.; Weickmann, A. M.; Djalalova, I.; McCaffrey, K.; Bianco, L.; Wilczak, J. M.; Newman, J. F.; Draxl, C.; Lundquist, J. K.; Wharton, S.; Olson, J.; Kenyon, J.; Marquis, M.
2017-12-01
In an effort to improve wind forecasts for the wind energy sector, the Department of Energy and the NOAA funded the second Wind Forecast Improvement Project (WFIP2). As part of the WFIP2 field campaign, a large suite of in-situ and remote sensing instrumentation was deployed to the Columbia River Gorge in Oregon and Washington from October 2015 - March 2017. The array of instrumentation deployed included 915-MHz wind profiling radars, sodars, wind- profiling lidars, and scanning lidars. The role of these instruments was to provide wind measurements at high spatial and temporal resolution for model evaluation and improvement of model physics. To properly determine model errors, the uncertainties in instrument-model comparisons need to be quantified accurately. These uncertainties arise from several factors such as measurement uncertainty, spatial variability, and interpolation of model output to instrument locations, to name a few. In this presentation, we will introduce a formalism to quantify measurement uncertainty and spatial variability. The accuracy of this formalism will be tested using existing datasets such as the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign. Finally, the uncertainties in wind measurement and the spatial variability estimates from the WFIP2 field campaign will be discussed to understand the challenges involved in model evaluation.
Assessment of the Influence of the RaD-X Balloon Payload on the Onboard Radiation Detectors
NASA Technical Reports Server (NTRS)
Gronoff, Guilluame; Mertens, Christopher J.; Norman, Ryan B.; Straume, Tore; Lusby, Terry C.
2016-01-01
The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. The instruments were housed in an aluminum structure protected by a foam cover. The structure partially shielded the detectors from cosmic rays but also created secondary particles, modifying the ambient radiation environment observed by the instruments. Therefore, it is necessary to account for the influence of the payload structure on the measured doses. In this paper, we present the results of modeling the effect of the balloon payload on the radiation detector measurements using a Geant-4 (GEometry ANd Tracking) application. Payload structure correction factors derived for the TEPC, Liulin, and TID instruments are provided as a function of altitude. Overall, the payload corrections are no more than a 7% effect on the radiation environment measurements.
In vitro and in vivo evaluations of three computer-aided shade matching instruments.
Yuan, Kun; Sun, Xiang; Wang, Fu; Wang, Hui; Chen, Ji-hua
2012-01-01
This study evaluated the accuracy and reliability of three computer-aided shade matching instruments (Shadepilot, VITA Easyshade, and ShadeEye NCC) using both in vitro and in vivo models. The in vitro model included the measurement of five VITA Classical shade guides. The in vivo model utilized three instruments to measure the central region of the labial surface of maxillary right central incisors of 85 people. The accuracy and reliability of the three instruments in these two evaluating models were calculated. Significant differences were observed in the accuracy of instruments both in vitro and in vivo. No significant differences were found in the reliability of instruments between and within the in vitro and the in vivo groups. VITA Easyshade was significantly different in accuracy between in vitro and in vivo models, while no significant difference was found for the other two instruments. Shadepilot was the only instrument tested in the present study that showed high accuracy and reliability both in vitro and in vivo. Significant differences were observed in the L*a*b* values of the 85 natural teeth measured using three instruments in the in vivo assessment. The pair-agreement rates of shade matching among the three instruments ranged from 37.7% to 48.2%, and the incidence of identical shade results shared by all three instruments was 25.9%. As different L*a*b* values and shade matching results were reported for the same tooth, a combination of the evaluated shade matching instruments and visual shade confirmation is recommended for clinical use.
Fayed, Nora; de Camargo, Olaf Kraus; Kerr, Elizabeth; Rosenbaum, Peter; Dubey, Ankita; Bostan, Cristina; Faulhaber, Markus; Raina, Parminder; Cieza, Alarcos
2012-12-01
Our aims were to (1) describe the conceptual basis of popular generic instruments according to World Health Organization (WHO) definitions of functioning, disability, and health (FDH), and quality of life (QOL) with health-related quality of life (HRQOL) as a subcomponent of QOL; (2) map the instruments to the International Classification of Functioning, Disability and Health (ICF); and (3) provide information on how the analyzed instruments were used in the literature. This should enable users to make valid choices about which instruments have the desired content for a specific context or purpose. Child health-based literature over a 5-year period was reviewed to find research employing health status and QOL/HRQOL instruments. WHO definitions of FDH and QOL were applied to each item of the 15 most used instruments to differentiate measures of FDH and QOL/HRQOL. The ICF was used to describe the health and health-related content (if any) in those instruments. Additional aspects of instrument use were extracted from these articles. Many instruments that were used to measure QOL/HRQOL did not reflect WHO definitions of QOL. The ICF domains within instruments were highly variable with respect to whether body functions, activities and participation, or environment were emphasized. There is inconsistency among researchers about how to measure HRQOL and QOL. Moreover, when an ICF content analysis is applied, there is variability among instruments in the health components included and emphasized. Reviewing content is important for matching instruments to their intended purpose. © The Authors. Developmental Medicine & Child Neurology © 2012 Mac Keith Press.
Evaluating musical instruments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, D. Murray
Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians.
A novel approach to reduce environmental noise in microgravity measurements using a Scintrex CG5
NASA Astrophysics Data System (ADS)
Boddice, Daniel; Atkins, Phillip; Rodgers, Anthony; Metje, Nicole; Goncharenko, Yuriy; Chapman, David
2018-05-01
The accuracy and repeatability of microgravity measurements for surveying purposes are affected by two main sources of noise; instrument noise from the sensor and electronics, and environmental sources of noise from anthropogenic activity, wind, microseismic activity and other sources of vibrational noise. There is little information in the literature on the quantitative values of these different noise sources and their significance for microgravity measurements. Experiments were conducted to quantify these sources of noise with multiple instruments, and to develop methodologies to reduce these unwanted signals thereby improving the accuracy or speed of microgravity measurements. External environmental sources of noise were found to be concentrated at higher frequencies (> 0.1 Hz), well within the instrument's bandwidth. In contrast, the internal instrumental noise was dominant at frequencies much lower than the reciprocal of the maximum integration time, and was identified as the limiting factor for current instruments. The optimum time for integration was found to be between 120 and 150 s for the instruments tested. In order to reduce the effects of external environmental noise on microgravity measurements, a filtering and despiking technique was created using data from noisy environments next to a main road and outside on a windy day. The technique showed a significant improvement in the repeatability of measurements, with between 40% and 50% lower standard deviations being obtained over numerous different data sets. The filtering technique was then tested in field conditions by using an anomaly of known size, and a comparison made between different filtering methods. Results showed improvements with the proposed method performing better than a conventional, or boxcar, averaging process. The proposed despiking process was generally found to be ineffective, with greater gains obtained when complete measurement records were discarded. Field survey results were worse than static measurement results, possibly due to the actions of moving the Scintrex during the survey which caused instability and elastic relaxation in the sensor, or the liquid tilt sensors, which generated additional low frequency instrument noise. However, the technique will result in significant improvements to accuracy and a reduction of measurement time, both for static measurements, for example at reference sites and observatories, and for field measurements using the next generation of instruments based on new technology, such as atom interferometry, resulting in time and cost savings.
NASA Astrophysics Data System (ADS)
Dorn, H.-P.; Brauers, T.; Greif, J.; Häseler, R.; Hofzumahaus, A.; Holland, F.; Rupp, L.
2003-04-01
A striking advantage of the SAPHIR chamber is the availability of two spectroscopic detection instruments for OH radicals: Laser-Induced Fluorescence Spectroscopy (LIF) and Long-Path Differential Optical Laser Absorption Spectroscopy (DOAS). Both instruments have already been compared in 1994 during the field measurement campaign POPCORN. They agreed well with a correlation coefficient of r=0.90 and a weighted linear fit with a slope of 1.09 +- 0.12. However, OH measurements in the simulation chamber differ significantly from measurements in ambient air. While DOAS measures OH as an integral value along the central longitudinal axis of SAPHIR, LIF samples the air locally and close (2 cm) to the floor of the chamber. Thus, the LIF measurements might be possibly affected by local concentration gradients caused by insufficient mixing of the chamber air or by deposition to the wall. On the other hand, if turbulent mixing of the chamber air is weak and high concentrations of ozone are used in experiments, the DOAS instrument might be subject to artificial formation of OH radicals in the air volume which is illuminated by the detection laser. This interference results from laser induced photolysis of ozone and the subsequent reaction of water vapor with the excited oxygen atoms formed. Thus it is of decisive importance to compare OH measurements from both instruments in order to investigate potential disturbing effects due to the specific sampling properties of both instruments within SAPHIR. We report on OH measurements accomplished simultaneously with both instruments using different trace gas compositions and experimental conditions.
The Measurement of Aerosol Optical Properties using Continuous Wave Cavity Ring-Down Techniques
NASA Technical Reports Server (NTRS)
Strawa, Anthony W.; Castaneda, Rene; Owano, Thomas; Baer, Douglas S.; Paldus, Barbara A.; Gore, Warren J. (Technical Monitor)
2002-01-01
Large uncertainties in the effects that aerosols have on climate require improved in situ measurements of extinction coefficient and single-scattering albedo. This paper describes the use of continuous wave cavity ring-down (CW-CRD) technology to address this problem. The innovations in this instrument are the use of CW-CRD to measure aerosol extinction coefficient, the simultaneous measurement of scattering coefficient, and small size suitable for a wide range of aircraft applications. Our prototype instrument measures extinction and scattering coefficient at 690 nm and extinction coefficient at 1550 nm. The instrument itself is small (60 x 48 x 15 cm) and relatively insensitive to vibrations. The prototype instrument has been tested in our lab and used in the field. While improvements in performance are needed, the prototype has been shown to make accurate and sensitive measurements of extinction and scattering coefficients. Combining these two parameters, one can obtain the single-scattering albedo and absorption coefficient, both important aerosol properties. The use of two wavelengths also allows us to obtain a quantitative idea of the size of the aerosol through the Angstrom exponent. Minimum sensitivity of the prototype instrument is 1.5 x 10(exp -6)/m (1.5 M/m). Validation of the measurement of extinction coefficient has been accomplished by comparing the measurement of calibration spheres with Mie calculations. This instrument and its successors have potential to help reduce uncertainty currently associated with aerosol optical properties and their spatial and temporal variation. Possible applications include studies of visibility, climate forcing by aerosol, and the validation of aerosol retrieval schemes from satellite data.
The Measurement of Aerosol Optical Properties Using Continuous Wave Cavity Ring-Down Techniques
NASA Technical Reports Server (NTRS)
Strawa, A. W.; Owano, T.; Castaneda, R.; Baer, D. S.; Paldus, B. A.; Gore, Warren J. (Technical Monitor)
2002-01-01
Large uncertainties in the effects that aerosols have on climate require improved in-situ measurements of extinction coefficient and single-scattering albedo. This abstract describes the use of continuous wave cavity ring-down (CW-CRD) technology to address this problem. The innovations in this instrument are the use of CW-CRD to measure aerosol extinction coefficient, the simultaneous measurement of scattering coefficient, and small size suitable for a wide range of aircraft applications. Our prototype instrument measures extinction and scattering coefficient at 690 nm and extinction coefficient at 1550 nm. The instrument itself is small (60 x 48 x 15 cm) and relatively insensitive to vibrations. The prototype instrument has been tested in our lab and used in the field. While improvements in performance are needed, the prototype has been shown to make accurate and sensitive measurements of extinction and scattering coefficients. Combining these two parameters, one can obtain the single-scattering albedo and absorption coefficient, both important aerosol properties. The use of two wavelengths also allows us to obtain a quantitative idea of the size of the aerosol through the Angstrom exponent. Minimum sensitivity of the prototype instrument is 1.5 x 10(exp -6)/m (1.5/Mm). Validation of the measurement of extinction coefficient has been accomplished by comparing the measurement of calibration spheres with Mie calculations. This instrument and its successors have potential to help reduce uncertainty currently associated with aerosol optical properties and their spatial and temporal variation. Possible applications include studies of visibility, climate forcing by aerosol, and the validation of aerosol retrieval schemes from satellite data.
Scanning system, infrared noise equivalent temperature difference: Measurement procedure
NASA Technical Reports Server (NTRS)
Cannon, J. B., Jr.
1975-01-01
A procedure is described for determining the noise equivalent difference temperature for infrared electro-optical instruments. The instrumentation required, proper measurements, and methods of calculation are included.
Measurements of Aperture Averaging on Bit-Error-Rate
NASA Technical Reports Server (NTRS)
Bastin, Gary L.; Andrews, Larry C.; Phillips, Ronald L.; Nelson, Richard A.; Ferrell, Bobby A.; Borbath, Michael R.; Galus, Darren J.; Chin, Peter G.; Harris, William G.; Marin, Jose A.;
2005-01-01
We report on measurements made at the Shuttle Landing Facility (SLF) runway at Kennedy Space Center of receiver aperture averaging effects on a propagating optical Gaussian beam wave over a propagation path of 1,000 in. A commercially available instrument with both transmit and receive apertures was used to transmit a modulated laser beam operating at 1550 nm through a transmit aperture of 2.54 cm. An identical model of the same instrument was used as a receiver with a single aperture that was varied in size up to 20 cm to measure the effect of receiver aperture averaging on Bit Error Rate. Simultaneous measurements were also made with a scintillometer instrument and local weather station instruments to characterize atmospheric conditions along the propagation path during the experiments.
Measurements of aperture averaging on bit-error-rate
NASA Astrophysics Data System (ADS)
Bastin, Gary L.; Andrews, Larry C.; Phillips, Ronald L.; Nelson, Richard A.; Ferrell, Bobby A.; Borbath, Michael R.; Galus, Darren J.; Chin, Peter G.; Harris, William G.; Marin, Jose A.; Burdge, Geoffrey L.; Wayne, David; Pescatore, Robert
2005-08-01
We report on measurements made at the Shuttle Landing Facility (SLF) runway at Kennedy Space Center of receiver aperture averaging effects on a propagating optical Gaussian beam wave over a propagation path of 1,000 m. A commercially available instrument with both transmit and receive apertures was used to transmit a modulated laser beam operating at 1550 nm through a transmit aperture of 2.54 cm. An identical model of the same instrument was used as a receiver with a single aperture that was varied in size up to 20 cm to measure the effect of receiver aperture averaging on Bit Error Rate. Simultaneous measurements were also made with a scintillometer instrument and local weather station instruments to characterize atmospheric conditions along the propagation path during the experiments.
Lucchetti, Giancarlo; Lucchetti, Alessandra Lamas Granero; Vallada, Homero
2013-01-01
Despite numerous spirituality and/or religiosity (S/R) measurement tools for use in research worldwide, there is little information on S/R instruments in the Portuguese language. The aim of the present study was to map out the S/R scales available for research in the Portuguese language. Systematic review of studies found in databases. A systematic review was conducted in three phases. Phases 1 and 2: articles in Portuguese, Spanish and English, published up to November 2011, dealing with the Portuguese translation and/or validation of S/R measurement tools for clinical research, were selected from six databases. Phase 3: the instruments were grouped according to authorship, cross-cultural adaptation, internal consistency, concurrent and discriminative validity and test-retest procedures. Twenty instruments were found. Forty-five percent of these evaluated religiosity, 40% spirituality, 10% religious/spiritual coping and 5% S/R. Among these, 90% had been produced in (n = 3) or translated to (n = 15) Brazilian Portuguese and two (10%) solely to European Portuguese. Nevertheless, the majority of the instruments had not undergone in-depth psychometric analysis. Only 40% of the instruments presented concurrent validity, 45% discriminative validity and 15% a test-retest procedure. The characteristics of each instrument were analyzed separately, yielding advantages, disadvantages and psychometric properties. Currently, 20 instruments for measuring S/R are available in the Portuguese language. Most have been translated (n = 15) or developed (n = 3) in Brazil and present good internal consistency. Nevertheless, few instruments have been assessed regarding all their psychometric qualities.
Henzlova, Daniela; Menlove, Howard Olsen; Rael, Carlos D.; ...
2015-10-09
Our paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. We describe the initial feasibility demonstration of the CIPN instrument, which involved measurements of fourmore » pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. Lastly, these features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henzlova, Daniela; Menlove, Howard Olsen; Rael, Carlos D.
Our paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. We describe the initial feasibility demonstration of the CIPN instrument, which involved measurements of fourmore » pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. Lastly, these features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.« less
NASA Astrophysics Data System (ADS)
Zhang, Jie; Marto, Joseph P.; Schwab, James J.
2018-05-01
Two optical scattering instruments for particle mass measurement, the Thermo Personal Data RAM (PDR-1500) and the TSI Environmental DustTrak DRX (Model 8543) were evaluated by (1) using poly- and mono-disperse test aerosol in the laboratory, and (2) sampling ambient aerosol. The responses of these optical scattering instruments to different particle characteristics (size, composition, concentration) were compared with responses from reference instruments. A Mie scattering calculation was used to explain the dependence of the optical instruments' response to aerosol size and composition. Concurrently, the detection efficiency of one Alphasense Optical Particle Counter (OPC-N2) was evaluated in the laboratory as well. The relationship between aerosol mass concentration and optical scattering was determined to be strongly dependent on aerosol size and to a lesser extent on aerosol composition (as reflected in the refractive indices of the materials tested) based on ambient measurements. This confirms that there is no simple way to use optical scattering instruments over a wide range of conditions without adjustments based on knowledge of aerosol size and composition. In particular, a test period measuring ambient aerosol with optical scattering instruments and a mass based method (an Aerodyne Aerosol Mass Spectrometer) determined that roughly two thirds of the variance (R2 = 0.64) of the optical to mass signal ratio is explained by the aerosol mass median diameter alone. These observations and calculations help evaluate the applicability and limitations of these optical scattering instruments, and provide guidance to designing suitable applications for each instrument by considering aerosol sources and aerosol size.
NASA Astrophysics Data System (ADS)
Liou, Pey-Yan; Kuo, Pei-Jung
2014-05-01
Background:Few studies have examined students' attitudinal perceptions of technology. There is no appropriate instrument to measure senior high school students' motivation and self-regulation toward technology learning among the current existing instruments in the field of technology education. Purpose:The present study is to validate an instrument for assessing senior high school students' motivation and self-regulation towards technology learning. Sample:A total of 1822 Taiwanese senior high school students (1020 males and 802 females) responded to the newly developed instrument. Design and method:The Motivation and Self-regulation towards Technology Learning (MSRTL) instrument was developed based on the previous instruments measuring students' motivation and self-regulation towards science learning. Exploratory and confirmatory factor analyses were utilized to investigate the structure of the items. Cronbach's alpha was applied for measuring the internal consistency of each scale. Furthermore, multivariate analysis of variance was used to examine gender differences. Results:Seven scales, including 'Technology learning self-efficacy,' 'Technology learning value,' 'Technology active learning strategies,' 'Technology learning environment stimulation,' 'Technology learning goal-orientation,' 'Technology learning self-regulation-triggering,' and 'Technology learning self-regulation-implementing' were confirmed for the MSRTL instrument. Moreover, the results also showed that male and female students did not present the same degree of preference in all of the scales. Conclusions:The MSRTL instrument composed of seven scales corresponding to 39 items was shown to be valid based on validity and reliability analyses. While male students tended to express more positive and active performance in the motivation scales, no gender differences were found in the self-regulation scales.
2011-01-01
Background Psychometric properties include validity, reliability and sensitivity to change. Establishing the psychometric properties of an instrument which measures three-dimensional human posture are essential prior to applying it in clinical practice or research. Methods This paper reports the findings of a systematic literature review which aimed to 1) identify non-invasive three-dimensional (3D) human posture-measuring instruments; and 2) assess the quality of reporting of the methodological procedures undertaken to establish their psychometric properties, using a purpose-build critical appraisal tool. Results Seventeen instruments were identified, of which nine were supported by research into psychometric properties. Eleven and six papers respectively, reported on validity and reliability testing. Rater qualification and reference standards were generally poorly addressed, and there was variable quality reporting of rater blinding and statistical analysis. Conclusions There is a lack of current research to establish the psychometric properties of non-invasive 3D human posture-measuring instruments. PMID:21569486
Development of Low-Cost Instrumentation for Single Point Autofluorescence Lifetime Measurements.
Lagarto, João; Hares, Jonathan D; Dunsby, Christopher; French, Paul M W
2017-09-01
Autofluorescence lifetime measurements, which can provide label-free readouts in biological tissues, contrasting e.g. different types and states of tissue matrix components and different cellular metabolites, may have significant clinical potential for diagnosis and to provide surgical guidance. However, the cost of the instrumentation typically used currently presents a barrier to wider implementation. We describe a low-cost single point time-resolved autofluorescence instrument, exploiting modulated laser diodes for excitation and FPGA-based circuitry for detection, together with a custom constant fraction discriminator. Its temporal accuracy is compared against a "gold-standard" instrument incorporating commercial TCSPC circuitry by resolving the fluorescence decays of reference fluorophores presenting single and double exponential decay profiles. To illustrate the potential to read out intrinsic contrast in tissue, we present preliminary measurements of autofluorescence lifetime measurements of biological tissues ex vivo. We believe that the lower cost of this instrument could enhance the potential of autofluorescence lifetime metrology for clinical deployment and commercial development.
AC resistance measuring instrument
Hof, P.J.
1983-10-04
An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.
AC Resistance measuring instrument
Hof, Peter J.
1983-01-01
An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.
The Next Spaceflight Solar Irradiance Sensor: TSIS
NASA Astrophysics Data System (ADS)
Kopp, Greg; Pilewskie, Peter; Richard, Erik
2016-05-01
The Total and Spectral Solar Irradiance Sensor (TSIS) will continue measurements of the solar irradiance with improved accuracies and stabilities over extant spaceflight instruments. The two TSIS solar-observing instruments include the Total Irradiance Monitor (TIM) and the Spectral Irradiance Monitor (SIM) for measuring total- and spectral- solar-irradiance, respectively. The former provides the net energy powering the Earth’s climate system while the latter helps attribute where that energy is absorbed by the Earth’s atmosphere and surface. Both spaceflight instruments are assembled and being prepared for integration on the International Space Station. With operations commencing in late 2017, the TSIS is intended to overlap with NASA’s ongoing SOlar Radiation and Climate Experiment (SORCE) mission, which launched in 2003 and contains the first versions of both the TIM and SIM instruments, as well as with the TSI Calibration Transfer Experiment (TCTE), which began total solar irradiance measurements in 2013. We summarize the TSIS’s instrument improvements and intended solar-irradiance measurements.
Portable Instrument to Measure CDOM Light Absorption in Aquatic Systems: WPI Success Story
NASA Technical Reports Server (NTRS)
2001-01-01
World Precision Instruments, Inc. (WPI), of Sarasota, FL, in collaboration with NASA's John C. Stennis Space Center, has developed an innovative instrument to accurately measure Colored Dissolved Organic Matter (CDOM) absorption in the field. This successful collaboration has culminated in an exciting new device, called the UltraPath, now commercially available through WPI. Traditional methods of measuring absorption of dissolved materials require special handling and storage prior to measurement. Use of laboratory spectrophotometers as the measuring devices have proven time consuming, cumbersome, and delicate to handle. The UltraPath provides a low-cost, highly sensitive, rugged, portable system that is capable of high sensitivity measurements in widely divergent waters.
Hsueh, Pei-Yun S; Zhu, Xinxin; Deng, Vincent; Ramarishnan, Sreeram; Ball, Marion
2014-01-01
Patient engagement is important to help patients become more informed and active in managing their health. Effective patient engagement demands short, yet valid instruments for measuring self-efficacy in various care dimensions. However, the static instruments are often too lengthy to be effective for assessment purposes. Furthermore, these tests could neither account for the dynamicity of measurements over time, nor differentiate care dimensions that are more critical to certain sub-populations. To remedy these disadvantages, we devise a dynamic instrument composition approach that can model the measurement of patient self-efficacy over time and iteratively select critical care dimensions and appropriate assessment questions based on dynamic user categorization. The dynamically composed instruments are expected to guide patients through self-management reinforcement cycles within or across care dimensions, while tightly integrated into clinical workflow and standard care processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, Matthew B; Niedziela, Jennifer L; Abernathy, Douglas L
The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments is not exclusive and overlaps significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems.more » We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, M. B.; Abernathy, D. L.; Ehlers, G.
The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. Wemore » have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.« less
Psychometric testing of the clinical nurse leader staff satisfaction instrument.
Spiva, LeeAnna; Hart, Patricia L; Wesley, Mary Lou; Gallagher, Erin; McVay, Frank; Waggoner, Jessica; Jarrell, Nicole; Threatt, Jamie L
2014-01-01
Patient care is changing rapidly with increased complexity of care, patient volumes, and financial constraints with rising health care costs and limited reimbursements. In response, the clinical nurse leader (CNL) role was developed. No appropriate instrument exists to measure staff satisfaction with the CNL role. This study describes the development and testing of an instrument designed to measure staff satisfaction with implementation of the CNL role. The psychometric properties and factor structure of the Clinical Nurse Leader Staff Satisfaction (CNLSS) instrument was examined. A 2-factor solution was discovered for the CNLSS. Cronbach's alpha coefficients were acceptable for the subscales and instrument. The CNLSS is a valid and reliable instrument. Future research should focus on establishing test-retest reliability and construct validity.
Design of an 8-40 GHz Antenna for the Wideband Instrument for Snow Measurements (WISM)
NASA Technical Reports Server (NTRS)
Durham, Timothy E.; Vanhille, Kenneth J.; Trent, Christopher; Lambert, Kevin M.; Miranda, Felix A.
2015-01-01
Measurement of land surface snow remains a significant challenge in the remote sensing arena. Developing the tools needed to remotely measure Snow Water Equivalent (SWE) is an important priority. The Wideband Instrument for Snow Measurements (WISM) is being developed to address this need. WISM is an airborne instrument comprised of a dual-frequency (X- and Ku-bands) Synthetic Aperture Radar (SAR) and dual-frequency (K- and Ka-bands) radiometer. A unique feature of this instrument is that all measurement bands share a common antenna aperture consisting of an array feed reflector that covers the entire bandwidth. This paper covers the design and fabrication of the wideband array feed which is based on tightly coupled dipole arrays. Implementation using a relatively new multi-layer microfabrication process results in a small, 6x6 element, dual-linear polarized array with beamformer that operates from 8 to 40 gigahertz.
How to Select a Questionnaire with a Good Methodological Quality?
Paiva, Saul Martins; Perazzo, Matheus de França; Ortiz, Fernanda Ruffo; Pordeus, Isabela Almeida; Martins-Júnior, Paulo Antônio
2018-01-01
In the last decades, several instruments have been used to evaluate the impact of oral health problems on the oral health-related quality of life (OHRQoL) of individuals. However, some instruments lack thorough methodological validation or present conceptual differences that hinder comparisons with instruments. Thus, it can be difficult to clinicians and researchers to select a questionnaire that accurately reflect what are really meaningful to individuals. This short communication aimed to discuss the importance of use an appropriate checklist to select an instrument with a good methodological quality. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist was developed to provide tools for evidence-based instrument selection. The COSMIN checklist comprises ten boxes that evaluate whether a study meets the standard for good methodological quality and two additional boxes to meet studies that use the Item Response Theory method and general requirements for results generalization, resulting in four steps to be followed. In this way, it is required at least some expertise in psychometrics or clinimetrics to a wide-ranging use of this checklist. The COSMIN applications include its use to ensure the standardization of cross-cultural adaptations and safer comparisons between measurement studies and evaluation of methodological quality of systematic reviews of measurement properties. Also, it can be used by students when training about measurement properties and by editors and reviewers when revising manuscripts on this topic. The popularization of COSMIN checklist is therefore necessary to improve the selection and evaluation of health measurement instruments.
NASA Technical Reports Server (NTRS)
Vasilyev, Y. M.; Lagunov, L. F.
1973-01-01
The schematic diagram of a noise measuring device is presented that uses pulse expansion modeling according to the peak or any other measured values, to obtain instrument readings at a very low noise error.
Sub-microradian Surface Slope Metrology with the ALS Developmental Long Trace Profiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, Valeriy V; Barber, Samuel; Domning, Edward E.
2009-09-11
A new low budget slope measuring instrument, the Developmental Long Trace Profiler (DLTP), was recently brought to operation at the ALS Optical Metrology Laboratory. The design, instrumental control and data acquisition system, initial alignment and calibration procedures, as well as the developed experimental precautions and procedures are described in detail. The capability of the DLTP to achieve sub-microradian surface slope metrology is verified via cross-comparison measurements with other high performance slope measuring instruments when measuring the same high quality test optics. The directions of future work to develop a surface slope measuring profiler with nano-radian performance are also discussed.
Measurements of stratospheric composition using a star pointing spectrometer
NASA Technical Reports Server (NTRS)
Fish, Deb J.; Jones, Rod L.; Freshwater, Ray A.; Roscoe, Howard K.; Oldham, Derek J.
1994-01-01
Measurements of stratospheric composition have been made with a novel star-pointing spectrometer. The instrument consists of a telescope that focuses light from stars, planets, or the moon onto a spectrometer and two dimensional CCD array detector. Atmospheric absorptions can be measured, from which atmospheric columns of several gases can be determined. The instrument was deployed in Abisko, 69 deg N, during the European Arctic Stratospheric Ozone Experiment (EASOE). The instrument has the potential for measuring O3, OClO, NO2, and NO3. In this paper, a method for the retrieval of vertical columns is described, and some examples of ozone measurements given.
Turvey, Carolyn L; Nazi, Kim M; Holman, John E; Hogan, Timothy P; Shimada, Stephanie L; Kennedy, Diana R
2017-01-01
Background Significant resources are being invested into eHealth technology to improve health care. Few resources have focused on evaluating the impact of use on patient outcomes A standardized set of metrics used across health systems and research will enable aggregation of data to inform improved implementation, clinical practice, and ultimately health outcomes associated with use of patient-facing eHealth technologies. Objective The objective of this project was to conduct a systematic review to (1) identify existing instruments for eHealth research and implementation evaluation from the patient’s point of view, (2) characterize measurement components, and (3) assess psychometrics. Methods Concepts from existing models and published studies of technology use and adoption were identified and used to inform a search strategy. Search terms were broadly categorized as platforms (eg, email), measurement (eg, survey), function/information use (eg, self-management), health care occupations (eg, nurse), and eHealth/telemedicine (eg, mHealth). A computerized database search was conducted through June 2014. Included articles (1) described development of an instrument, or (2) used an instrument that could be traced back to its original publication, or (3) modified an instrument, and (4) with full text in English language, and (5) focused on the patient perspective on technology, including patient preferences and satisfaction, engagement with technology, usability, competency and fluency with technology, computer literacy, and trust in and acceptance of technology. The review was limited to instruments that reported at least one psychometric property. Excluded were investigator-developed measures, disease-specific assessments delivered via technology or telephone (eg, a cancer-coping measure delivered via computer survey), and measures focused primarily on clinician use (eg, the electronic health record). Results The search strategy yielded 47,320 articles. Following elimination of duplicates and non-English language publications (n=14,550) and books (n=27), another 31,647 articles were excluded through review of titles. Following a review of the abstracts of the remaining 1096 articles, 68 were retained for full-text review. Of these, 16 described an instrument and six used an instrument; one instrument was drawn from the GEM database, resulting in 23 articles for inclusion. None included a complete psychometric evaluation. The most frequently assessed property was internal consistency (21/23, 91%). Testing for aspects of validity ranged from 48% (11/23) to 78% (18/23). Approximately half (13/23, 57%) reported how to score the instrument. Only six (26%) assessed the readability of the instrument for end users, although all the measures rely on self-report. Conclusions Although most measures identified in this review were published after the year 2000, rapidly changing technology makes instrument development challenging. Platform-agnostic measures need to be developed that focus on concepts important for use of any type of eHealth innovation. At present, there are important gaps in the availability of psychometrically sound measures to evaluate eHealth technologies. PMID:29021128
On the comparison between MASS and generalized-SCIDAR techniques
NASA Astrophysics Data System (ADS)
Masciadri, E.; Lombardi, G.; Lascaux, F.
2014-02-01
The Multi-Aperture Scintillation Sensor (MASS) and the Generalized-Scintillation Detection and Ranging (Generalized-SCIDAR) are two instruments conceived to measure the optical turbulence vertical distribution on the whole troposphere and low stratosphere (˜20 km) widely used in the astronomical context. In this paper, we perform a detailed analysis/comparison of measurements provided by the two instruments and taken during the extended site testing campaign carried out in 2007 at Cerro Paranal and promoted by the European Southern Observatory. The main and final goal of the study is to provide a detailed estimation of the measurements reliability, i.e. dispersion of turbulence measurements done by the two instruments at different heights above the ground. This information is directly related to our ability in estimating the absolute value of the turbulence stratification. To better analyse the uncertainties between the MASS and the Generalized-SCIDAR we took advantage of the availability of measurements taken during the same campaign by a third independent instrument called Differential Image Motion Monitor (DIMM) measuring the integrated turbulence extended on the whole 20 km. Such a cross-check comparison permitted us to define the reliability of the instruments and their measurements, their limits and the contexts in which their use can present some risk.
Multiwavelength Shack-Hartmann aberrometer
NASA Astrophysics Data System (ADS)
Jain, Prateek
Measurement of higher order optical aberrations in the human eye has become important and common place now days, particularly in the advent of custom Lasik surgery and adaptive optics. The most widely used instrument in the industry and clinics is the Shack-Hartmann Aberrometer that utilizes the Shack-Hartmann sensor to measure the aberrations of the eye. The standard SH aberrometer is made of a chin rest and requires the subject to look at the target with one eye and measures the aberrations at an infrared wavelength which is generally 780 nm. This research work adds two improvements to the standard instrument. These two new SH aberrometers have been built and tested on Human subjects. The first modification is to make the aberrometer portable and unobtrusive so that it can be hand held and the subject is allowed to look at the target with both eyes. This instrument is called the Unobtrusive SH Aberrometer (USHA). The second modification is to measure the aberrations at three visible wavelengths spanning the visible spectrum so as to not only measure the aberrations over the visible spectrum but also measure the chromatic aberration. This instrument is called the Multiwavelength SH Aberrometer (MSHA). This instrument is probably a first of its kind, capable measuring the in vivo chromatic aberration in a single image.
Craving and relapse measurement in alcoholism.
Potgieter, A S; Deckers, F; Geerlings, P
1999-01-01
This paper attempts to summarize the measurement of craving with four different craving instruments and to relate this to definitions and measurement of relapse. The definitions of relapse may vary between studies and researchers, but are usually well defined. Five commonly used methods to measure relapse are: (1) quantity/frequency of drinking; (2) cumulative duration of abstinence (CDA); (3) post-withdrawal abstinent period; (4) stable recovery period; (5) the time line follow-back method. The definition of craving is much less clear and is mostly described as an emotional-motivational state or as obsessive-compulsive behaviour. Four self-rating instruments are briefly discussed and compared: the Obsessive-Compulsive Drinking Scale, OCDS, the Lübeck Craving Scale, LCRR, the Alcohol Craving Questionnaire, ACQ-Now-SF-R, and ordinal scales (e.g. visual analogue, Likert, or verbal descriptive scales). These instruments measure different aspects or dimensions of craving over different periods. The different dimensions measured suggest that there is still a need to conceptualize a standard interpretation of the word craving. There is a need also to measure an emotional-motivational dimension, a cognitive-behavioural dimension, expectancies, and effects on positive and negative reinforcement with different instruments or with one multidimensional instrument. It is suggested that different patients are expected to have different craving profiles.
Blaker, Kendra M; Plotto, Anne; Baldwin, Elizabeth A; Olmstead, James W
2014-01-01
BACKGROUND Fruit texture is a primary selection trait in southern highbush blueberry (SHB) breeding to increase fresh fruit postharvest quality and consumer acceptance. A novel crisp fruit texture has recently been identified among SHB germplasm. In this study, we developed a common set of descriptors that align sensory evaluation of blueberry fruit texture with instrumental measures that could be used for quantitative measurements during pre- and postharvest evaluation. RESULTS Sensory and instrumental characteristics were measured in 36 and 49 genotypes in 2010 and 2011, respectively. A trained sensory panel evaluated fresh fruit based on five common textural attributes in 2010 and 2011: bursting energy, flesh firmness, skin toughness, juiciness and mealiness. Instrumental measures of compression and bioyield forces were significantly different among cultivars and correlated with sensory scores for bursting energy, flesh firmness and skin toughness (R > 0.7, except skin toughness in 2011), but correlations with sensory scores for juiciness and mealiness were low (R < 0.4). CONCLUSION The results of sensory and instrumental measures supported the use of both compression and bioyield force measures in distinguishing crisp from standard-texture genotypes, and suggest that crisp texture in SHB is related to the sensory perception of bursting energy, flesh firmness and skin toughness. PMID:24619938
Endedijk, Maaike D; Brekelmans, Mieke; Sleegers, Peter; Vermunt, Jan D
Self-regulated learning has benefits for students' academic performance in school, but also for expertise development during their professional career. This study examined the validity of an instrument to measure student teachers' regulation of their learning to teach across multiple and different kinds of learning events in the context of a postgraduate professional teacher education programme. Based on an analysis of the literature, we developed a log with structured questions that could be used as a multiple-event instrument to determine the quality of student teachers' regulation of learning by combining data from multiple learning experiences. The findings showed that this structured version of the instrument measured student teachers' regulation of their learning in a valid and reliable way. Furthermore, with the aid of the Structured Learning Report individual differences in student teachers' regulation of learning could be discerned. Together the findings indicate that a multiple-event instrument can be used to measure regulation of learning in multiple contexts for various learning experiences at the same time, without the necessity of relying on students' ability to rate themselves across all these different experiences. In this way, this instrument can make an important contribution to bridging the gap between two dominant approaches to measure SRL, the traditional aptitude and event measurement approach.
CSP-IEEE Instrumentation and Measurement Technology Conference 2016 (IEEE 12MTC 2016)
2016-08-22
Advanced Measurement and Instrumentation for NDT&E • Instrumentation and measurement for improving quality, reliability and safety : new...the Conference is in Asia , therefore China , Taiwan , Malaysia , and India were on the list. As for the acceptance rat ion , Austria , Italy, UK...15 69.4% Brazil 14 7 66.7% USA 15 6 71.4% Malaysia 12 10 54 .5% Germany 9 3 75.0% United Kingdom 10 2 83 .3% Canada 8 2 80.0% Austria 10 0
System Measures Pressures Aboard A Compressor Rotor
NASA Technical Reports Server (NTRS)
Freedman, Robert J.; Senyitko, Richard G.; Blumenthal, Philip Z.
1994-01-01
Rotating pressure-measuring instrumentation includes on-board calibration standard. Computer-controlled, multichannel instrumentation system acquires pressure measurements from sensors mounted in 1.52-m-diameter rotor of compressor. Includes 5 miniature, electronically scanned pressure (ESP) modules, each containing 48 piezoresistive pressure sensors, pneumatic calibration valve, and electronic circuits for addressing and amplifying output of each sensor. Modules mounted on centerline of rotor, on instrumentation tower located inside nose cone of rotor. Subsystem designed to convert analog signal to distinct frequency without significantly affecting accuracy.
Wideband Instrument for Snow Measurements (WISM)
NASA Technical Reports Server (NTRS)
Miranda, Felix A.; Lambert, Kevin M.; Romanofsky, Robert R.; Durham, Tim; Speed, Kerry; Lange, Robert; Olsen, Art; Smith, Brett; Taylor, Robert; Schmidt, Mark;
2016-01-01
This presentation discusses current efforts to develop a Wideband Instrument for Snow Measurements (WISM). The objective of the effort are as follows: to advance the utility of a wideband active and passive instrument (8-40 gigahertz) to support the snow science community; improve snow measurements through advanced calibration and expanded frequency of active and passive sensors; demonstrate science utility through airborne retrievals of snow water equivalent (SWE); and advance the technology readiness of broadband current sheet array (CSA) antenna technology for spaceflight applications.
Remote sensing technology research and instrumentation platform design
NASA Technical Reports Server (NTRS)
1992-01-01
An instrumented pallet concept and definition of an aircraft with performance and payload capability to meet NASA's airborne turbulent flux measurement needs for advanced multiple global climate research and field experiments is presented. The report addresses airborne measurement requirements for general circulation model sub-scale parameterization research, specifies instrumentation capable of making these measurements, and describes a preliminary support pallet design. Also, a review of aircraft types and a recommendation of a manned and an unmanned aircraft capable of meeting flux parameterization research needs is given.
Flight set 360L003 instrumentation final test report, volume 9
NASA Technical Reports Server (NTRS)
1989-01-01
Post-flight instrumentation hardware and data evaluation for 360L003 is summarized. The 360L003 motors were equipped with Developmental Flight Instrumentation (DFI), Operational Flight Instrumentation (OFI), and Ground Environmental Instrumentation (GEI). The DFI was designed to measure strain, temperature, pressure, and vibration at various locations on the motor during flight. The DFI is used to validate engineering models in a flight environment. The OFI consists of six Operational Pressure Tranducers which monitor chamber pressure during flight. These pressure transducers are used in the SRB separation cue. GEI measures the motor case, igniter flange, and nozzle temperature prior to launch.
ARIES NDA Robot operators` manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheer, N.L.; Nelson, D.C.
1998-05-01
The ARIES NDA Robot is an automation device for servicing the material movements for a suite of Non-destructive assay (NDA) instruments. This suite of instruments includes a calorimeter, a gamma isotopic system, a segmented gamma scanner (SGS), and a neutron coincidence counter (NCC). Objects moved by the robot include sample cans, standard cans, and instrument plugs. The robot computer has an RS-232 connection with the NDA Host computer, which coordinates robot movements and instrument measurements. The instruments are expected to perform measurements under the direction of the Host without operator intervention. This user`s manual describes system startup, using the mainmore » menu, manual operation, and error recovery.« less
Harvard ER-2 OH laser-induced fluorescence instrument
NASA Technical Reports Server (NTRS)
Wennberg, Paul O.; Anderson, James G.
1994-01-01
The Harvard ER-2 OH instrument is scheduled to be integrated into the NASA ER-2 high altitude aircraft ozone payload in August 1992. Design and fabrication is presently underway. This experiment is a descendant of a balloon borne instrument designed and built in the mid-1980s. The ER-2 instrument is being designed to measure OH and HO2 as part of the NASA ozone payload for the investigation of processes controlling the concentration of stratospheric ozone. Although not specifically designed to do so, it is hoped that valid measurements of OH and HO2 can be made in the remote free troposphere with this instrument.
Measuring teamwork in health care settings: a review of survey instruments.
Valentine, Melissa A; Nembhard, Ingrid M; Edmondson, Amy C
2015-04-01
Teamwork in health care settings is widely recognized as an important factor in providing high-quality patient care. However, the behaviors that comprise effective teamwork, the organizational factors that support teamwork, and the relationship between teamwork and patient outcomes remain empirical questions in need of rigorous study. To identify and review survey instruments used to assess dimensions of teamwork so as to facilitate high-quality research on this topic. We conducted a systematic review of articles published before September 2012 to identify survey instruments used to measure teamwork and to assess their conceptual content, psychometric validity, and relationships to outcomes of interest. We searched the ISI Web of Knowledge database, and identified relevant articles using the search terms team, teamwork, or collaboration in combination with survey, scale, measure, or questionnaire. We found 39 surveys that measured teamwork. Surveys assessed different dimensions of teamwork. The most commonly assessed dimensions were communication, coordination, and respect. Of the 39 surveys, 10 met all of the criteria for psychometric validity, and 14 showed significant relationships to nonself-report outcomes. Evidence of psychometric validity is lacking for many teamwork survey instruments. However, several psychometrically valid instruments are available. Researchers aiming to advance research on teamwork in health care should consider using or adapting one of these instruments before creating a new one. Because instruments vary considerably in the behavioral processes and emergent states of teamwork that they capture, researchers must carefully evaluate the conceptual consistency between instrument, research question, and context.
Wang, Zuocheng; Calderón, Leonardo; Patton, Allison P; Sorensen Allacci, MaryAnn; Senick, Jennifer; Wener, Richard; Andrews, Clinton J; Mainelis, Gediminas
2016-11-01
This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM 2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM 2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM 2.5 mass concentration compared to the PMI 2.5 filter. The pDR-1500 direct reading and PMI 2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R 2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R 2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R 2 = 0.936 for OPC versus pDR-1500 reading and R 2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real-time monitors is convenient for measurement of airborne PM at short time scales, the accuracy of those monitors depends on a particular instrument. Bias correction factors identified in this paper could provide guidance for other studies using direct-reading instruments to measure PM concentrations.
Development of a Transportable Gravity Gradiometer Based on Atom Interferometry
NASA Astrophysics Data System (ADS)
Yu, N.; Kohel, J. M.; Aveline, D. C.; Kellogg, J. R.; Thompson, R. J.; Maleki, L.
2007-12-01
JPL is developing a transportable gravity gradiometer based on light-pulse atom interferometers for NASA's Earth Science Technology Office's Instrument Incubator Program. The inertial sensors in this instrument employ a quantum interference measurement technique, analogous to the precise phase measurements in atomic clocks, which offers increased sensitivity and improved long-term stability over traditional mechanical devices. We report on the implementation of this technique in JPL's gravity gradiometer, and on the current performance of the mobile instrument. We also discuss the prospects for satellite-based gravity field mapping, including high-resolution monitoring of time-varying fields from a single satellite platform and multi-component measurements of the gravitational gradient tensor, using atom interferometer-based instruments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reisler, R.E.; Keefer, J.H.; Ethridge, N.H.
1995-03-01
Blast wave measurement techniques and instrumentation developed by Military Applications of Blast Simulators (MABS) participating countries to study blast phenomena during the nuclear era are summarized. Passive and active gages both mechanical self-recording and electronic systems deployed on kiloton and megaton explosive tests during the period 1945-1963 are presented. The country and the year the gage was introduced are included with the description. References are also provided. Volume 2 covers measurement techniques and instrumentation for the period 1959-1993 and Volume 3 covers structural target and gage calibration from 1943 to 1993.
ERIC Educational Resources Information Center
Ramful, Ajay; Lowrie, Thomas; Logan, Tracy
2017-01-01
This article describes the development and validation of a newly designed instrument for measuring the spatial ability of middle school students (11-13 years old). The design of the Spatial Reasoning Instrument (SRI) is based on three constructs (mental rotation, spatial orientation, and spatial visualization) and is aligned to the type of spatial…
ERIC Educational Resources Information Center
Rutledge, Michael L.; Sadler, Kim C.
2007-01-01
The Measure of Acceptance of the Theory of Evolution (MATE) instrument was initially designed to assess high school biology teachers' acceptance of evolutionary theory. To determine if the MATE instrument is reliable with university students, it was administered to students in a non-majors biology course (n = 61) twice over a 3-week period.…
Development of an Instrument for the Measurement of Leadership Commitment to Organizational Process
ERIC Educational Resources Information Center
Hylton, Peter D.
2013-01-01
The purpose of this research study was to create a new instrument designed to examine the commitment of an organization's leadership to following organizational processes, as measured by stakeholder perceptions. This instrument was designed to aid in closure of a gap in the field of leadership studies relative to the impact that a leader's…
ERIC Educational Resources Information Center
Knaus, Karen J.; Murphy, Kristen L.; Holme, Thomas A.
2009-01-01
The design and use of a chemistry practice exam instrument that includes a measure for student mental effort is described in this paper. Use of such an instrument can beneficial to chemistry students and chemistry educators as well as chemical education researchers from both a content and cognitive science perspective. The method for calculating…
Instrumentation for the Atmospheric Explorer photoelectron spectrometer
NASA Technical Reports Server (NTRS)
Peletier, D. P.
1973-01-01
The photoelectron spectrometer (PES) is part of the complements of scientific instruments aboard three NASA Atmosphere Explorer (AE) satellites. The PES measures the energy spectrum, angular distribution, and intensity of electrons in the earth's thermosphere. Measurements of energies between 2 and 500 eV are made at altitudes as low as 130 km. The design, characteristics, and performance of the instrument are described.
ERIC Educational Resources Information Center
Bjerke, Annette Hessen; Eriksen, Elisabeta
2016-01-01
This article reports on the use of Rasch modelling to develop and validate an instrument measuring self-efficacy in tutoring children in primary mathematics (SETcPM). In response to the literature on teacher efficacy, the 20-item instrument aims to inform teacher educators, and is designed for novice pre-service teachers (nPSTs) preparing to teach…
ERIC Educational Resources Information Center
Taylor, Bryan; Kroth, Michael
2009-01-01
This article is a meta-analysis of the theory of andragogy and its search for a measurable instrument. The article explores three areas surrounding andragogy: (a) its concept and history, (b) its assumptions, and (c) its primary criticisms. In examining these three areas, a foundation is established for the creation of an instrument to provide…
ERIC Educational Resources Information Center
Wilkes, Sam T.; Blackbourn, Joe M.
This project attempts to refine the Zones of Indifference Instrument, (included in appendix) that measures zones of indifference of teachers to typical directives issued by administrators. As a result of the original validation study, a 78-item, two-factor instrument was developed. These two factors explained 52 percent of the variance. The…
Development and Validation of Scores from an Instrument Measuring Student Test-Taking Motivation
ERIC Educational Resources Information Center
Eklof, Hanna
2006-01-01
Using the expectancy-value model of achievement motivation as a basis, this study's purpose is to develop, apply, and validate scores from a self-report instrument measuring student test-taking motivation. Sampled evidence of construct validity for the present sample indicates that a number of the items in the instrument could be used as an…
ERIC Educational Resources Information Center
Aryadoust, Vahid; Mehran, Parisa; Alizadeh, Mehrasa
2016-01-01
A few computer-assisted language learning (CALL) instruments have been developed in Iran to measure EFL (English as a foreign language) learners' attitude toward CALL. However, these instruments have no solid validity argument and accordingly would be unable to provide a reliable measurement of attitude. The present study aimed to develop a CALL…
The Role of Naturally Occurring Stable Isotopes in Mass Spectrometry, Part II: The Instrumentation
Bluck, Les; Volmer, Dietrich A.
2013-01-01
In the second instalment of this tutorial, the authors explain the instrumentation for measuring naturally occurring stable isotopes, specifically the magnetic sector mass spectrometer. This type of instrument remains unrivalled in its performance for isotope ratio mass spectrometry (IRMS) and the reader is reminded of its operation and its technical advantages for isotope measurements. PMID:23772101
ERIC Educational Resources Information Center
Liu, Ou Lydia; Jackson, Teresa; Ling, Guangming
2008-01-01
Learning strategies have been increasingly recognized as a useful tool to promote effective learning. In response to the lack of available learning strategies measures for middle school students, this study designed an instrument for these students, assessing behavioral, cognitive, and metacognitive strategies. This instrument, the Middle School…
ERIC Educational Resources Information Center
Kaur, Daisy; Zhao, Yi
2017-01-01
The present study is focused on the detailed description of Physics Attitude Scale (PAS) to measure students' attitudes toward physics. The development of this new instrument involved extensive interviews with both the experts as well as the students. This was followed by expert reviews and pilot testing of the instrument. The duly revised draft…
ERIC Educational Resources Information Center
Talbot, Robert M., III
2017-01-01
There is a clear need for valid and reliable instrumentation that measures teacher knowledge. However, the process of investigating and making a case for instrument validity is not a simple undertaking; rather, it is a complex endeavor. This paper presents the empirical case of one aspect of such an instrument validation effort. The particular…
Comparing tiltmeters for crustal deformation measurement--a preliminary report.
Wyatt, F; Bilham, R; Beavan, J; Sylvester, A G; Owen, T; Harvey, A; Macdonald, C; Jackson, D D; Agnew, D C
1984-10-01
A collection of high-precision tiltmeters is being operated at Pinon Flat Observatory, southern California, both to compare instruments and to measure tectonic deformation. We report on 1.2 years of data from four of these: two Michelson-Gale long fluid tiltmeters, one long center-pressure tiltmeter, and a shallow borehole tiltmeter. The three long-base instruments are all located on the same baseline, with a precise leveling line running between their end-monuments. At nontidal frequencies, only the two Michelson-Gale instruments show some coherence (gamma 2 = .3 for periods of 2 to 4 days), while the center-pressure instrument is correlated with air temperature at periods from a few days to a few weeks. The most stable tilt record shows a secular rate of 0.28 mu rad/a, which may be real. Over much longer times, leveling to specially stabilized bench-marks should confirm this. Comparing instruments has identified more and less successful measurement techniques; it appears that low-noise data will most probably be produced only by relatively complex and expensive instruments, though even for these, the operating costs over any reasonable lifetime will exceed the capital cost. Even the best existing sensors must be improved to measure continuous tectonic motions.
Measuring first-line nurse manager work: instrument: development and testing.
Cadmus, Edna; Wisniewska, Edyta K
2013-12-01
The objective of this study was to develop and test a 1st-line nurse manager (FLNM) work instrument to measure categories of work and frequency of activities. First-line nurse managers have been demonstrated to be key contributors in meeting organizational outcomes and patient and nurse satisfaction. Identifying the work of FLNMs is essential to help in the development of prioritization and sequence. The need for an instrument that can measure and categorize the work of FLNMs is indicated. The author-developed instrument was administered as a pilot study to 173 FLNMs in New Jersey. Descriptive statistics were analyzed, and validity and reliability were measured. Content validity was established through 2 focus groups using 10 FLNMs and conducting a survey of 5 chief nursing officers. Reliability was assessed by 13 of 16 FLNM participants using the test/retest method and quantified using percent agreement within a 10-day period. Those items with 70% agreement or more were identified as reliable and retained on the instrument. The content validity of the instrument is strong; further refinement and testing of the tool are indicated to improve the reliability and generalizability across multiple populations of leaders and settings.
Measuring emotional intelligence of medical school applicants.
Carrothers, R M; Gregory, S W; Gallagher, T J
2000-05-01
To discuss the development, pilot testing, and analysis of a 34-item semantic differential instrument for measuring medical school applicants' emotional intelligence (the EI instrument). The authors analyzed data from the admission interviews of 147 1997 applicants to a six-year BS/MD program that is composed of three consortium universities. They compared the applicants' scores on traditional admission criteria (e.g., GPA and traditional interview assessments) with their scores on the EI instrument (which comprised five dimensions of emotional intelligence), breaking the data out by consortium university (each of which has its own educational ethos) and gender. They assessed the EI instrument's reliability and validity for assessing noncognitive personal and interpersonal qualities of medical school applicants. The five dimensions of emotional intelligence (maturity, compassion, morality, sociability, and calm disposition) indicated fair to excellent internal consistency: reliability coefficients were .66 to .95. Emotional intelligence as measured by the instrument was related to both being female and matriculating at the consortium university that has an educational ethos that values the social sciences and humanities. Based on this pilot study, the 34-item EI instrument demonstrates the ability to measure attributes that indicate desirable personal and interpersonal skills in medical school applicants.
Organizational Capabilities for Integrating Care: A Review of Measurement Tools.
Evans, Jenna M; Grudniewicz, Agnes; Baker, G Ross; Wodchis, Walter P
2016-12-01
The success of integrated care interventions is highly dependent on the internal and collective capabilities of the organizations in which they are implemented. Yet, organizational capabilities are rarely described, understood, or measured with sufficient depth and breadth in empirical studies or in practice. Assessing these capabilities can contribute to understanding why some integrated care interventions are more effective than others. We identified, organized, and assessed survey instruments that measure the internal and collective organizational capabilities required for integrated care delivery. We conducted an expert consultation and searched Medline and Google Scholar databases for survey instruments measuring factors outlined in the Context and Capabilities for Integrating Care Framework. A total of 58 instruments were included in the review and assessed based on their psychometric properties, practical considerations, and applicability to integrated care efforts. This study provides a bank of psychometrically sound instruments for describing and comparing organizational capabilities. Greater use of these instruments across integrated care interventions and studies can enhance standardized comparative analyses and inform change management. Further research is needed to build an evidence base for these instruments and to explore the associations between organizational capabilities and integrated care processes and outcomes. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Kraus, Adam H.
Moisture within a transformer's insulation system has been proven to degrade its dielectric strength. When installing a transformer in situ, one method used to calculate the moisture content of the transformer insulation is to measure the dew point temperature of the internal gas volume of the transformer tank. There are two instruments commercially available that are designed for dew point temperature measurement: the Alnor Model 7000 Dewpointer and the Vaisala DRYCAPRTM Hand-Held Dewpoint Meter DM70. Although these instruments perform an identical task, the design technology behind each instrument is vastly different. When the Alnor Dewpointer and Vaisala DM70 instruments are used to measure the dew point of the internal gas volume simultaneously from a pressurized transformer, their differences in dew point measurement have been observed to vary as much as 30 °F. There is minimal scientific research available that focuses on the process of measuring dew point of a gas inside a pressurized transformer, let alone this observed phenomenon. The primary objective of this work was to determine what effect certain factors potentially have on dew point measurements of a transformer's internal gas volume, in hopes of understanding the root cause of this phenomenon. Three factors that were studied include (1) human error, (2) the use of calibrated and out-of-calibration instruments, and (3) the presence of oil vapor gases in the dry air sample, and their subsequent effects on the Q-value of the sampled gas. After completing this portion of testing, none of the selected variables proved to be a direct cause of the observed discrepancies between the two instruments. The secondary objective was to validate the accuracy of each instrument as compared to its respective published range by testing against a known dew point temperature produced by a humidity generator. In a select operating range of -22 °F to -4 °F, both instruments were found to be accurate and within their specified tolerances. This temperature range is frequently encountered in oil-soaked transformers, and demonstrates that both instruments can measure accurately over a limited, yet common, range despite their different design methodologies. It is clear that there is another unknown factor present in oil-soaked transformers that is causing the observed discrepancy between these instruments. Future work will include testing on newly manufactured or rewound transformers in order to investigate other variables that could be causing this discrepancy.
QNOTE: an instrument for measuring the quality of EHR clinical notes.
Burke, Harry B; Hoang, Albert; Becher, Dorothy; Fontelo, Paul; Liu, Fang; Stephens, Mark; Pangaro, Louis N; Sessums, Laura L; O'Malley, Patrick; Baxi, Nancy S; Bunt, Christopher W; Capaldi, Vincent F; Chen, Julie M; Cooper, Barbara A; Djuric, David A; Hodge, Joshua A; Kane, Shawn; Magee, Charles; Makary, Zizette R; Mallory, Renee M; Miller, Thomas; Saperstein, Adam; Servey, Jessica; Gimbel, Ronald W
2014-01-01
The outpatient clinical note documents the clinician's information collection, problem assessment, and patient management, yet there is currently no validated instrument to measure the quality of the electronic clinical note. This study evaluated the validity of the QNOTE instrument, which assesses 12 elements in the clinical note, for measuring the quality of clinical notes. It also compared its performance with a global instrument that assesses the clinical note as a whole. Retrospective multicenter blinded study of the clinical notes of 100 outpatients with type 2 diabetes mellitus who had been seen in clinic on at least three occasions. The 300 notes were rated by eight general internal medicine and eight family medicine practicing physicians. The QNOTE instrument scored the quality of the note as the sum of a set of 12 note element scores, and its inter-rater agreement was measured by the intraclass correlation coefficient. The Global instrument scored the note in its entirety, and its inter-rater agreement was measured by the Fleiss κ. The overall QNOTE inter-rater agreement was 0.82 (CI 0.80 to 0.84), and its note quality score was 65 (CI 64 to 66). The Global inter-rater agreement was 0.24 (CI 0.19 to 0.29), and its note quality score was 52 (CI 49 to 55). The QNOTE quality scores were consistent, and the overall QNOTE score was significantly higher than the overall Global score (p=0.04). We found the QNOTE to be a valid instrument for evaluating the quality of electronic clinical notes, and its performance was superior to that of the Global instrument. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
The Jupiter Energetic Particle Detector Instrument (JEDI) Investigation for the Juno Mission
NASA Astrophysics Data System (ADS)
Mauk, B. H.; Haggerty, D. K.; Jaskulek, S. E.; Schlemm, C. E.; Brown, L. E.; Cooper, S. A.; Gurnee, R. S.; Hammock, C. M.; Hayes, J. R.; Ho, G. C.; Hutcheson, J. C.; Jacques, A. D.; Kerem, S.; Kim, C. K.; Mitchell, D. G.; Nelson, K. S.; Paranicas, C. P.; Paschalidis, N.; Rossano, E.; Stokes, M. R.
2017-11-01
The Jupiter Energetic Particle Detector Instruments (JEDI) on the Juno Jupiter polar-orbiting, atmosphere-skimming, mission to Jupiter will coordinate with the several other space physics instruments on the Juno spacecraft to characterize and understand the space environment of Jupiter's polar regions, and specifically to understand the generation of Jupiter's powerful aurora. JEDI comprises 3 nearly-identical instruments and measures at minimum the energy, angle, and ion composition distributions of ions with energies from H:20 keV and O: 50 keV to >1 MeV, and the energy and angle distribution of electrons from <40 to >500 keV. Each JEDI instrument uses microchannel plates (MCP) and thin foils to measure the times of flight (TOF) of incoming ions and the pulse height associated with the interaction of ions with the foils, and it uses solid state detectors (SSD's) to measure the total energy ( E) of both the ions and the electrons. The MCP anodes and the SSD arrays are configured to determine the directions of arrivals of the incoming charged particles. The instruments also use fast triple coincidence and optimum shielding to suppress penetrating background radiation and incoming UV foreground. Here we describe the science objectives of JEDI, the science and measurement requirements, the challenges that the JEDI team had in meeting these requirements, the design and operation of the JEDI instruments, their calibrated performances, the JEDI inflight and ground operations, and the initial measurements of the JEDI instruments in interplanetary space following the Juno launch on 5 August 2011. Juno will begin its prime science operations, comprising 32 orbits with dimensions 1.1×40 RJ, in mid-2016.
An Open-path Laser Transmissometer for Atmospheric Extinction Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chandran, P. M. Satheesh; Krishnakumar, C. P.; Varma, Ravi
2011-10-20
A transmissometer is an optical instrument which measures transmitted intensity of monochromatic light over a fixed pathlength. Prototype of a simple laser transmissometer has been developed for transmission (or extinction) measurements through suspended absorbers and scatterers in the atmosphere over tens of meters. Instrument consists of a continuous green diode pumped solid state laser, transmission optics, photodiode detectors and A/D data acquisition components. A modulated laser beam is transmitted and subsequently reflected and returned to the unit by a retroreflecting mirror assembly placed several tens of meters away. Results from an open-path field measurement of the instrument are described.
NASA Technical Reports Server (NTRS)
King, Michael C.; Bachalo, William; Kurek, Andrzej
2017-01-01
This paper presents particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.
NASA Technical Reports Server (NTRS)
King, Michael C.; Bachalo, William; Kurek, Andrzej
2017-01-01
This presentation shows particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.
Measuring the Use of ICTs in the Classroom
ERIC Educational Resources Information Center
Jamieson-Proctor, Romina; Watson, Glenice; Finger, Glenn; Grimbeek, Peter; Burnett, Paul C.
2007-01-01
In 2003, the "ICT Curriculum Integration Performance Measurement Instrument" was developed from an extensive review of the contemporary international and Australian research pertaining to the definition and measurement of ICT curriculum integration in classrooms (Proctor, Watson, & Finger, 2003). The 45-item instrument that resulted…
Reconciling the Differences between the Measurements of CO2 Isotopes by the Phoenix and MSL Landers
NASA Technical Reports Server (NTRS)
Niles, P. B.; Mahaffy, P. R.; Atreya, S.; Pavlov, A. A.; Trainer, M.; Webster, C. R.; Wong, M.
2014-01-01
Precise stable isotope measurements of the CO2 in the martian atmosphere have the potential to provide important constraints for our understanding of the history of volatiles, the carbon cycle, current atmospheric processes, and the degree of water/rock interaction on Mars. There have been several different measurements by landers and Earth based systems performed in recent years that have not been in agreement. In particular, measurements of the isotopic composition of martian atmospheric CO2 by the Thermal and Evolved Gas Analyzer (TEGA) instrument on the Mars Phoenix Lander and the Sample Analysis at Mars (SAM) instrument on the Mars Science Laboratory (MSL) are in stark disagreement. This work attempts to use measurements of mass 45 and mass 46 of martian atmospheric CO2 by the SAM and TEGA instruments to search for agreement as a first step towards reaching a consensus measurement that might be supported by data from both instruments.
Peest, Christian; Schinke, Carsten; Brendel, Rolf; Schmidt, Jan; Bothe, Karsten
2017-01-01
Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Cary 5000 in accordance with the Guide to the expression of uncertainty in measurements. We focus on the instrumentation-related uncertainty contributions rather than the specific application and thus outline a general procedure which can be adapted for other instruments. Moreover, we discover a systematic signal deviation due to the inertia of the measurement amplifier and develop and apply a correction procedure. Thereby we increase the usable dynamic range of the instrument by more than one order of magnitude. We present methods for the quantification of the uncertainty contributions and combine them into an uncertainty budget for the device.
An Automatic Instrument to Study the Spatial Scaling Behavior of Emissivity
Tian, Jing; Zhang, Renhua; Su, Hongbo; Sun, Xiaomin; Chen, Shaohui; Xia, Jun
2008-01-01
In this paper, the design of an automatic instrument for measuring the spatial distribution of land surface emissivity is presented, which makes the direct in situ measurement of the spatial distribution of emissivity possible. The significance of this new instrument lies in two aspects. One is that it helps to investigate the spatial scaling behavior of emissivity and temperature; the other is that, the design of the instrument provides theoretical and practical foundations for the implement of measuring distribution of surface emissivity on airborne or spaceborne. To improve the accuracy of the measurements, the emissivity measurement and its uncertainty are examined in a series of carefully designed experiments. The impact of the variation of target temperature and the environmental irradiance on the measurement of emissivity is analyzed as well. In addition, the ideal temperature difference between hot environment and cool environment is obtained based on numerical simulations. Finally, the scaling behavior of surface emissivity caused by the heterogeneity of target is discussed. PMID:27879735
ERIC Educational Resources Information Center
Schwella, E.; van Nieuwenhuyzen, Bernard J.
2014-01-01
Are South Africans financially literate, and how can this be measured? Until 2009 there was no South African financial literacy measure and, therefore, the aim was to develop a South African measurement instrument that is scientific, socially acceptable, valid and reliable. To achieve this aim a contextual and conceptual analysis of financial…
ACRF Instrumentation Status: New, Current, and Future - October – November 2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
JW Voyles
2007-11-30
The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF) instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) SBIR instrument development.
Quality of health literacy instruments used in children and adolescents: a systematic review.
Guo, Shuaijun; Armstrong, Rebecca; Waters, Elizabeth; Sathish, Thirunavukkarasu; Alif, Sheikh M; Browne, Geoffrey R; Yu, Xiaoming
2018-06-14
Improving health literacy at an early age is crucial to personal health and development. Although health literacy in children and adolescents has gained momentum in the past decade, it remains an under-researched area, particularly health literacy measurement. This study aimed to examine the quality of health literacy instruments used in children and adolescents and to identify the best instrument for field use. Systematic review. A wide range of settings including schools, clinics and communities. Children and/or adolescents aged 6-24 years. Measurement properties (reliability, validity and responsiveness) and other important characteristics (eg, health topics, components or scoring systems) of health literacy instruments. There were 29 health literacy instruments identified from the screening process. When measuring health literacy in children and adolescents, researchers mainly focus on the functional domain (basic skills in reading and writing) and consider participant characteristics of developmental change (of cognitive ability), dependency (on parents) and demographic patterns (eg, racial/ethnic backgrounds), less on differential epidemiology (of health and illness). The methodological quality of included studies as assessed via measurement properties varied from poor to excellent. More than half (62.9%) of measurement properties were unknown, due to either poor methodological quality of included studies or a lack of reporting or assessment. The 8-item Health Literacy Assessment Tool (HLAT-8) showed best evidence on construct validity, and the Health Literacy Measure for Adolescents showed best evidence on reliability. More rigorous and high-quality studies are needed to fill the knowledge gap in measurement properties of health literacy instruments. Although it is challenging to draw a robust conclusion about which instrument is the most reliable and the most valid, this review provides important evidence that supports the use of the HLAT-8 to measure childhood and adolescent health literacy in future school-based research. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin
2003-06-01
To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase "organizational culture." In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources.
Wilberforce, Mark; Challis, David; Davies, Linda; Kelly, Michael P; Roberts, Chris; Loynes, Nik
2016-03-07
Person-centredness is promoted as a central feature of the long-term care of older adults. Measures are needed to assist researchers, service planners and regulators in assessing this feature of quality. However, no systematic review exists to identify potential instruments and to provide a critical appraisal of their measurement properties. A systematic review of measures of person-centredness was undertaken. Inclusion criteria restricted references to multi-item instruments designed for older adult services, or otherwise with measurement properties tested in an older adult population. A two-stage critical appraisal was conducted. First, the methodological quality of included references was assessed using the COSMIN toolkit. Second, seven measurement properties were rated using widely-recognised thresholds of acceptability. These results were then synthesised to provide an overall appraisal of the strength of evidence for each measurement property for each instrument. Eleven measures tested in 22 references were included. Six instruments were designed principally for use in long-stay residential facilities, and four were for ambulatory hospital or clinic-based services. Only one measure was designed mainly for completion by users of home care services. No measure could be assessed across all seven measurement properties. Despite some instruments having promising measurement properties, this was consistently undermined by the poor methodological quality underpinning them. Testing of hypotheses to support construct validity was of particularly low quality, whilst measurement error was rarely assessed. Two measures were identified as having been the subject of the most rigorous testing. The review is unable to unequivocally recommend any measures of person-centredness for use in older adult care. Researchers are advised to improve methodological rigour when testing instruments. Efforts may be best focused on testing a narrower range of measurement properties but to a higher standard, and ensuring that translations to new languages are resisted until strong measurement properties are demonstrated in the original tongue. Limitations of the review include inevitable semantic and conceptual challenges involved in defining 'person-centredness'. The review protocol was registered with PROSPERO (ref: CRD42014005935).
Chow, Clara K.; Lock, Karen; Madhavan, Manisha; Corsi, Daniel J.; Gilmore, Anna B.; Subramanian, S. V.; Li, Wei; Swaminathan, Sumathi; Lopez-Jaramillo, Patricio; Avezum, Alvaro; Lear, Scott A.; Dagenais, Gilles; Teo, Koon; McKee, Martin; Yusuf, Salim
2010-01-01
Background The environment in which people live is known to be important in influencing diet, physical activity, smoking, psychosocial and other risk factors for cardiovascular (CV) disease. However no instrument exists that evaluates communities for these multiple environmental factors and is suitable for use across different communities, regions and countries. This report describes the design and reliability of an instrument to measure environmental determinants of CV risk factors. Method/Principal Findings The Environmental Profile of Community Health (EPOCH) instrument comprises two parts: (I) an assessment of the physical environment, and (II) an interviewer-administered questionnaire to collect residents' perceptions of their community. We examined the inter-rater reliability amongst 3 observers from each region of the direct observation component of the instrument (EPOCH I) in 93 rural and urban communities in 5 countries (Canada, Colombia, Brazil, China and India). Data collection using the EPOCH instrument was feasible in all communities. Reliability of the instrument was excellent (Intraclass Correlation Coefficient - ICC>0.75) for 24 of 38 items and fair to good (ICC 0.4–0.75) for 14 of 38 items. Conclusion This report shows data collection with the EPOCH instrument is feasible and direct observation of community measures reliable. The EPOCH instrument will enable further research on environmental determinants of health for population studies from a broad range of settings. PMID:21170320
Outcome instruments to assess scoliosis surgery.
Bagó, Juan; Climent, Jose Ma; Pérez-Grueso, Francisco J S; Pellisé, Ferran
2013-03-01
To review and summarize the current knowledge regarding the outcome measures used to evaluate scoliosis surgery. Literature review. Outcome instruments should be tested to ensure that they have adequate metric characteristics: content and construct validity, reliability, and responsiveness. In the evaluation of scoliosis, generic instruments to assess health-related quality of life (HRQL) have been used, such as the SF-36 questionnaire and the EuroQol5D instrument. Nonetheless, it is preferable to use disease-specific instruments for this purpose, such as the SRS-22 Patient Questionnaire and the quality of life profile for spinal deformities (QLPSD). More recently, these generic and disease-specific instruments have been complemented with the use of super-specific instruments; i.e., those assessing a single aspect of the condition or specific populations with the condition. The patients' perception of their trunk deformity and body image has received particular attention, and several instruments are available to evaluate these aspects, such as the Walter-Reed Visual Assessment Scale (WRVAS), the Spinal Appearance Questionnaire (SAQ), and the Trunk Appearance Perception Scale (TAPS). The impacts of brace use can also be measured with specific scales, including the Bad Sobernheim Stress Questionnaire (BSSQ) and the Brace Questionnaire (BrQ). The available instruments to evaluate the treatment for non-idiopathic scoliosis have not been sufficiently validated and analyzed. Evaluation of scoliosis treatment should include the patient's perspective, which can be obtained with the use of patient-reported outcome measures.
Zaror, Carlos; Pardo, Yolanda; Espinoza-Espinoza, Gerardo; Pont, Àngels; Muñoz-Millán, Patricia; Martínez-Zapata, María José; Vilagut, Gemma; Forero, Carlos G; Garin, Olatz; Alonso, Jordi; Ferrer, Montse
2018-03-22
To obtain a systematic and standardized evaluation of the current evidence on development process, metric properties, and administration issues of oral health-related quality of life instruments available for children and adolescents. A systematic search until October 2016 was conducted in PubMed, Embase, Lilacs, SciELO, and Cochrane databases. Articles with information regarding the development process, metric properties, and administration issues of pediatric instruments measuring oral health-related quality of life were eligible for inclusion. Two researchers independently evaluated each instrument applying the Evaluating Measures of Patient-Reported Outcomes (EMPRO) tool. An overall and seven attribute-specific EMPRO scores were calculated (range 0-100, worst to best): measurement model, reliability, validity, responsiveness, interpretability, burden, and alternative forms. We identified 18 instruments evaluated in 132 articles. From five instruments designed for preschoolers, the Early Childhood Oral Health Impact Scale (ECOHIS) obtained the highest overall EMPRO score (82.2). Of nine identified for schoolchildren and adolescents, the best rated instrument was the Child Perceptions Questionnaire 11-14 (82.1). Among the four instruments developed for any age, the Family Impact Scale (FIS) obtained the highest scores (80.3). The evidence supports the use of the ECOHIS for preschoolers, while the age is a key factor when choosing among the four recommended instruments for schoolchildren and adolescents. Instruments for specific conditions, symptoms, or treatments need further research on metric properties. Our results facilitate decision-making on the correct oral health-related quality of life instrument selection for any certain study purpose and population during the childhood and adolescence life cycle.
Evaluation of an immunosuppressant side effect instrument.
Winsett, Rebecca P; Arheart, Kris; Stratta, Robert J; Alloway, Rita; Wicks, Mona N; Gaber, A Osama; Hathaway, Donna K
2004-09-01
Clinicians continue to be compelled to evaluate the impact of immunosuppressive medication side effects on the quality of life of transplant recipients. We Were asked to develop an instrument to measure side effects in immunosuppressed transplant recipients. To construct an instrument that measures the impact and severity of side effects of immunosuppressive medications used in transplantation and to assess the reliability and validity of the newly developed instrument called the Memphis Survey. The instrument was constructed by a panel of physicians, nurses, and pharmacists with experience in treating transplant recipients. A small group of kidney transplant recipients (n= 13) provided pilot data for refining and testing the instrument. A national sample of kidney, liver, and heart transplant recipients (n = 505) provided data that were used to further develop the instrument. Factor analysis was used to determine the psychological dimensions underlying the instrument and to guide the construction of scales from the survey items. The instrument scales were then computed from the dataset of 505 transplant recipients to quantify the impact of immunosuppressant side effects on the quality of life of transplant recipients. Analyses showed the final instrument scales to be valid and reliable. Exploratory analysis suggests the need for further testing of the instrument to determine gender differences.
An Autonomous Ozone Instrument for Atmospheric Measurements from Ocean Buoys
NASA Astrophysics Data System (ADS)
Hintsa, E. J.; Rawlins, W. T.; Sholkovitz, E. R.; Hosom, D. S.; Allsup, G. P.; Purcell, M. J.; Scott, D. R.; Mulhall, P.
2002-05-01
Tropospheric ozone is an oxidant, a greenhouse gas, and a pollutant. Because of its adverse health effects, there are numerous monitoring stations on land but none over the oceans. We have built an ozone instrument for deployment anywhere at sea from ocean buoys, to study ozone chemistry over the oceans, intercontinental transport of pollution, diurnal and seasonal cycles of ozone, and to make baseline and long-term time series measurements of ozone in remote locations. The instrument uses direct (Beer's Law) absorption of UV radiation in a dual-path cell, with ambient and ozone-free air alternately switched between the two paths, to measure ozone. Ozone can be measured at a rate of 1 Hz, with a precision of about 1 ppb at sea level. The air inlet and outlet have valves which close automatically under high wind conditions or rain to protect the ozone sensor. The instrument has been packaged for deployment at sea, and tested on a 3-meter discus buoy with other instruments in coastal waters in fall 2001. It can operate autonomously or be controlled via line-of-sight modem or a satellite link. We will present the details of the instrument, and laboratory and buoy test data from its first deployment, including a comparison with a nearby ozone monitoring station on land. We will also present an evaluation of the instrument's performance and describe plans for improvements. In summer 2002, the ozone measurement system will be operated at the Martha's Vineyard Coastal Observatory; in the future we anticipate deploying on the Bermuda Testbed Mooring, followed by use on the open ocean to measure long-range transport of ozone.
Instrumentation for measuring and recording streamflow data at river-control structures
,
1983-01-01
Instrumentation was developed in the mid to late 60 's to resolve the dilemma of intolerably high percentages of missing streamflow records on certain large and highly controlled streams in industrialized parts of the United States. Analysis of the field situation at specific problem sites quickly suggested that conventional stream gaging techniques should be supplanted by new instruments, designed to measure key hydraulic data at the nearest stream control structures. The key data were found universally to include some combination of a length measurement to specify the vertical height of a gate opening in a dam; measurement of pressure head differential in a turbine; a count of lockages; and precise measurement of time, to give one master reference scale to which all measurements could be keyed. The instruments designed to collect such key data are the shaft position digitizer, the shaft output follower, the STACOM manometer, the lock pressure switch, and the digital data collection console. Although their design was prompted by the need to collect data at river control structures their potential for field use is not that restrictive. Several of these instruments have already found widespread use in the hydrologic data collection program at large. In the 12-1/2 yr period from June 1968 to December 1980 nineteen different river control structures were instrumented. The general experience to date has been a marked improvement in completeness of record, with the average performance somewhere in the 80 percentile range. Performance percentiles at individual sites have ranged from the mid 90 's to about 70. Maintenance records show the instruments to be virtually trouble free, except for the unpredictable acts of nature and man. (Author 's abstract)
NASA Astrophysics Data System (ADS)
Shankar, Mohan; Priestley, Kory; Smith, Nathaniel; Smith, Nitchie; Thomas, Susan; Walikainen, Dale
2015-10-01
The Clouds and Earth's Radiant Energy System (CERES) instruments help to study the impact of clouds on the earth's radiation budget. There are currently five instruments- two each on board Aqua and Terra spacecraft and one on the Suomi NPP spacecraft to measure the earth's reflected shortwave and emitted longwave energy, which represent two components of the earth's radiation energy budget. Flight Models (FM) 1 and 2 are on Terra, FM 3 and 4 are on Aqua, and FM5 is on Suomi NPP. The measurements are made by three sensors on each instrument: a shortwave sensor that measures the 0.3-5 microns wavelength band, a window sensor that measures the water vapor window between 8-12 microns, and a total sensor that measures all incident energy (0.3- >100 microns). The required accuracy of CERES measurements of 0.5% in the longwave and 1% in the shortwave is achieved through an extensive pre-launch ground calibration campaign as well as on-orbit calibration and validation activities. Onorbit calibration is carried out using the Internal Calibration Module (ICM) that consists of a tungsten lamp, blackbodies, and a solar diffuser known as the Mirror Attenuator Mosaic (MAM). The ICM calibration provides information about the stability of the sensors' broadband radiometric gains on-orbit. Several validation studies are conducted in order to monitor the behavior of the instruments in various spectral bands. The CERES Edition-4 data products for the FM1-FM4 instruments incorporate the latest calibration methodologies to improve on the Edition-3 data products. In this paper, we discuss the updated calibration methodology and present some validation studies to demonstrate the improvement in the trends using the CERES Edition-4 data products for all four instruments.