Sample records for insulin delivery systems

  1. Some engineering aspects of insulin delivery systems.

    PubMed

    Spencer, W J; Bair, R E; Carlson, G A; Love, J T; Urenda, R S; Eaton, R P; Schade, D S

    1980-01-01

    The characteristics of electronically controlled insulin delivery systems are presented. Early experiments with an external system have shown promise in providing improved glycemic control over conventional methods of single or multiple subcutaneous insulin injections. The encouraging results with external insulin delivery systems have led to the development and early testing in dogs of an implantable system with remote controls to permit variable insulin flow rates. A number of questions remain to be answered before widespread experimentation with external and implanted insulin delivery systems is possible. There appears to be no major development problems with the engineering aspects of such systems.

  2. Oral Insulin Delivery: How Far Are We?

    PubMed Central

    Fonte, Pedro; Araújo, Francisca; Reis, Salette; Sarmento, Bruno

    2013-01-01

    Oral delivery of insulin may significantly improve the quality of life of diabetes patients who routinely receive insulin by the subcutaneous route. In fact, compared with this administration route, oral delivery of insulin in diabetes treatment offers many advantages: higher patient compliance, rapid hepatic insulinization, and avoidance of peripheral hyperinsulinemia and other adverse effects such as possible hypoglycemia and weight gain. However, the oral delivery of insulin remains a challenge because its oral absorption is limited. The main barriers faced by insulin in the gastrointestinal tract are degradation by proteolytic enzymes and lack of transport across the intestinal epithelium. Several strategies to deliver insulin orally have been proposed, but without much clinical or commercial success. Protein encapsulation into nanoparticles is regarded as a promising alternative to administer insulin orally because they have the ability to promote insulin paracellular or transcellular transport across the intestinal mucosa. In this review, different delivery systems intended to increase the oral bioavailability of insulin will be discussed, with a special focus on nanoparticulate carrier systems, as well as the efforts that pharmaceutical companies are making to bring to the market the first oral delivery system of insulin. The toxicological and safety data of delivery systems, the clinical value and progress of oral insulin delivery, and the future prospects in this research field will be also scrutinized. PMID:23567010

  3. Controlled delivery of basal insulin from phase-sensitive polymeric systems after subcutaneous administration: in vitro release, stability, biocompatibility, in vivo absorption, and bioactivity of insulin.

    PubMed

    Al-Tahami, Khaled; Oak, Mayura; Singh, Jagdish

    2011-06-01

    The purpose of this study was to investigate the phase-sensitive delivery systems (D,L-polylactide in triacetin) for controlled delivery of insulin at basal level. The effect of varying concentration of zinc, polymer, and insulin on the in vitro release of insulin was evaluated. Stability of released insulin was investigated by differential scanning calorimetry, circular dichroism, and matrix-assisted laser desorption/ionization time of flight mass spectrometry. In Vivo insulin absorption and bioactivity were studied in diabetic rats. In vitro and In Vivo biocompatibility of delivery systems were evaluated by 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide assay and skin histology, respectively. Extended release profiles of insulin for 2, 4, and 8 weeks from delivery systems containing 20%, 30%, and 40% (w/v) polymer concentration was observed. A ratio of 1:5 insulin hexamer to zinc was shown to be optimum. Physical and chemical stability of released insulin was greatly conserved. In Vivo studies demonstrated controlled release of insulin with reduction in blood glucose for approximately 1 month. In vitro and In Vivo studies demonstrated that the delivery system was biocompatible and controlled the delivery of insulin for longer durations after single subcutaneous injection. Copyright © 2010 Wiley-Liss, Inc.

  4. Recent Updates on Novel Approaches in Insulin Drug Delivery: A Review of Challenges and Pharmaceutical Implications.

    PubMed

    Pandey, Manisha; Choudhury, Hira; Yi, Cheah Xiao; Mun, Chen Wei; Ping, Goh Khang; Rou, Guee Xin; Singh, Bhalqish Jeet Kaur A/P Ambar Jeet; Jhee, Angel Ng Ann; Chin, Lee Kai; Kesharwani, Prashant; Gorain, Bapi; Hussain, Zahid

    2018-05-22

    Diabetes mellitus, a metabolic disorder of glucose metabolism, is mainly associated with insulin resistance to the body cells, or impaired production of insulin by the pancreatic β-cells. Insulin is mainly required to regulate glucose metabolism in type 1 diabetes mellitus patients; however, many patients with type 2 diabetes mellitus also require insulin, especially when their condition cannot be controlled solely by oral hypoglycemic agents. Hence, major researches are ongoing attempting to improve the delivery of insulin in order to make it more convenient to patients who experience side effects from the conventional treatment procedure or non-adherence to insulin regimen due to multiple comorbid conditions. Conventionally, insulin is administered via subcutaneous route which is also one of the sole reasons of patient's non-compliance due to the invasiveness of this method. Several attempts have been done to improve patient compliance, reduce side effects, improve delivery adherence, and to enhance pharmaceutical performance of the insulin therapy. Despite of facing substantial challenges in developing efficient delivery systems for insulin, vast researches have been carried out for the development of smart delivery systems to delivery insulin via ocular, buccal, pulmonary, oral, transdermal, as well as rectal routes. Therefore, the present review was aimed to overview the challenges encountered with the current insulin delivery systems and to summarize recent advancements in technology of various novel insulin delivery systems being discovered and introduced in the current market. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Insulin delivery route for the artificial pancreas: subcutaneous, intraperitoneal, or intravenous? Pros and cons.

    PubMed

    Renard, Eric

    2008-07-01

    Insulin delivery is a crucial component of a closed-loop system aiming at the development of an artificial pancreas. The intravenous route, which has been used in the bedside artificial pancreas model for 30 years, has clear advantages in terms of pharmacokinetics and pharmacodynamics, but cannot be used in any ambulatory system so far. Subcutaneous (SC) insulin infusion benefits from the broad expansion of insulin pump therapy that promoted the availability of constantly improving technology and fast-acting insulin analog use. However, persistent delays of insulin absorption and action, variability and shortterm stability of insulin infusion from SC-inserted catheters generate effectiveness and safety issues in view of an ambulatory, automated, glucose-controlled, artificial beta cell. Intraperitoneal insulin delivery, although still marginally used in diabetes care, may offer an interesting alternative because of its more-physiological plasma insulin profiles and sustained stability and reliability of insulin delivery.

  6. Calcium phosphate-PEG-insulin-casein (CAPIC) particles as oral delivery systems for insulin.

    PubMed

    Morçöl, T; Nagappan, P; Nerenbaum, L; Mitchell, A; Bell, S J D

    2004-06-11

    An oral delivery system for insulin was developed and functional activity was tested in a non-obese diabetic (NOD) mice model. Calcium phosphate particles containing insulin was synthesized in the presence of PEG-3350 and modified by aggregating the particles with caseins to obtain the calcium phosphate-PEG-insulin-casein (CAPIC) oral insulin delivery system. Single doses of CAPIC formulation were tested in NOD mice under fasting or fed conditions to evaluate the glycemic activity. The blood glucose levels were monitored every 1-2h for 12h following the treatments using an ACCU CHECK blood glucose monitoring system. Orally administered and subcutaneously injected free insulin solution served as controls in the study. Based on the results obtained we propose that: (1). the biological activity of insulin is preserved in CAPIC formulation; (2). insulin in CAPIC formulations, but not the free insulin, displays a prolonged hypoglycemic effect after oral administration to diabetic mice; (3). CAPIC formulation protects insulin from degradation while passing through the acidic environment of the GI track until it is released in the less acidic environment of the intestines where it can be absorbed in its biologically active form; (4). CAPIC formulation represents a new and unique oral delivery system for insulin and other macromolecules.

  7. Effect of standard (self-directed) training versus intensive training for Lilly/Alkermes human insulin inhalation powder delivery system on patient-reported outcomes and patient evaluation of the system.

    PubMed

    Hayes, Risa P; Nakano, Masako; Muchmore, Douglas; Schmitke, Jennifer

    2007-02-01

    Inhaled insulin may provide patients with diabetes a safe, efficacious method of insulin delivery without the burden of injection, but complexity of and time required for training in proper use of delivery systems have not been evaluated. This 4-week, multicenter, single-blind, randomized parallel-group study compared the effect of self-directed [written text-graphic directions for use (DFU) with patient-assistance phone number] or intensive (same DFU, personal training by study personnel, inspiratory flow rate coaching) training for the Lilly/Alkermes human insulin inhalation powder (HIIP) delivery system on patient-reported outcomes (PROs). Patients with type 2 diabetes poorly controlled on oral therapy (n = 102, mean hemoglobin A1C = 9.3%) were administered measures of vitality, diabetes-associated symptoms, fear of hypoglycemia, insulin-delivery system satisfaction, and a delivery system-specific evaluation questionnaire. Analysis of covariance models were used to compare the effect on PROs of treatment of diabetes for 1 month following the two training methods. Paired t tests were used to determine change in PROs after treatment with HIIP. PROs did not differ significantly between training groups. Patients in both groups positively evaluated the delivery system, but the intensive group agreed significantly (P < 0.05) more strongly that the DFU was easy to follow. Improvements in vitality and symptoms of fatigue and increases in fear of hypoglycemia were detected among all patients after using HIIP (P < 0.05). Training for this HIIP delivery system can be self-directed without detrimental effects on PROs, making it potentially a more patient-friendly insulin-delivery method that should appeal to both clinicians and patients.

  8. Insulin regulates its own delivery to skeletal muscle by feed-forward actions on the vasculature

    PubMed Central

    Wang, Hong; Upchurch, Charles T.; Liu, Zhenqi

    2011-01-01

    Insulin, at physiological concentrations, regulates the volume of microvasculature perfused within skeletal and cardiac muscle. It can also, by relaxing the larger resistance vessels, increase total muscle blood flow. Both of these effects require endothelial cell nitric oxide generation and smooth muscle cell relaxation, and each could increase delivery of insulin and nutrients to muscle. The capillary microvasculature possesses the greatest endothelial surface area of the body. Yet, whether insulin acts on the capillary endothelial cell is not known. Here, we review insulin's actions at each of three levels of the arterial vasculature as well as recent data suggesting that insulin can regulate a vesicular transport system within the endothelial cell. This latter action, if it occurs at the capillary level, could enhance insulin delivery to muscle interstitium and thereby complement insulin's actions on arteriolar endothelium to increase insulin delivery. We also review work that suggests that this action of insulin on vesicle transport depends on endothelial cell nitric oxide generation and that insulin's ability to regulate this vesicular transport system is impaired by inflammatory cytokines that provoke insulin resistance. PMID:21610226

  9. Responsive materials for self-regulated insulin delivery.

    PubMed

    Wu, Weitai; Zhou, Shuiqin

    2013-11-01

    With diabetes mellitus becoming an important public health concern, insulin-delivery systems are attracting increasing interest from both scientific and technological researchers. This feature article covers the present state-of-the-art glucose-responsive insulin-delivery system (denoted as GRIDS), based on responsive polymer materials, a promising system for self-regulated insulin delivery. Three types of GRIDS are discussed, based on different fundamental mechanisms of glucose-recognition, with: a) glucose enzyme, b) glucose binding protein, and c) synthetic boronic acid as the glucose-sensitive component. At the end, a personal perspective on the major issues yet to be worked out in future research is provided. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Progress of Oral Insulin and Related Drug Delivery Systems and their Pharmacokinetics.

    PubMed

    Chen, Jingjing; Liu, Rui; Liu, Changxiao; Jin, Xin; Zhang, Qinghua; Wang, Jialu; Zhao, Fang; Wang, Ze; Qiu, Haiyan; Li, Yazhuo; Yi, Xiulin

    2018-05-22

    As society has developed and living standards have improved, diabetes has become a severe public health issue. Insulin plays a crucial role in managing hyperglycemia caused by type I diabetes and particular type II diabetes. Many researchers are seeking alternative, more acceptable methods of insulin delivery, such as oral insulin. An oral formulation has become a new goal for insulin delivery in recent years. The PubMed and CNKI databases were searched for "oral insulin, " "drug delivery systems, " and "pharmacokinetics, " and 85 relevant articles were selected from the results as material for this review. These papers were authoritative and had a higher number of citations. Oral insulin would be highly advantageous but is poorly absorbed. The main reason for low absorptivity is the hydrolysis of insulin by enzymes in the gastrointestinal tract. Lack of active transport vectors that pass through the intestinal epithelium is also a non-negligible problem. Additional issues need to be considered to facilitate appropriate research, such as long-term efficacy and safety, clinical data, and toxicological characteristics. This review summarized recent advances in oral insulin and the pharmacokinetic profile of the suitable delivery system, providing valuable reference material for future research. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Glucose-Responsive Supramolecular Vesicles Based on Water-Soluble Pillar[5]arene and Pyridylboronic Acid Derivatives for Controlled Insulin Delivery.

    PubMed

    Gao, Lei; Wang, Tingting; Jia, Keke; Wu, Xuan; Yao, Chenhao; Shao, Wei; Zhang, Dongmei; Hu, Xiao-Yu; Wang, Leyong

    2017-05-11

    The stimuli-responsive behavior of supramolecular nanocarriers is crucial for their potential applications as smart drug delivery systems. We hereby constructed a glucose-responsive supramolecular drug delivery system based on the host-guest interaction between a water-soluble pillar[5]arene (WP5) and a pyridylboronic acid derivative (G) for insulin delivery and controlled release under physiological conditions. The approach represents the ideal treatment of diabetes mellitus. The drug loading and in vitro drug release experiments demonstrated that large molecular weight insulin could be encapsulated into the vesicles with high loading efficiency, which, to our knowledge, is the first example of small-size supramolecular vesicles with excellent encapsulation capacity of a large protein molecule. Moreover, FITC-labeled insulin was used to evaluate the release behavior of insulin, and it was demonstrated that high glucose concentration could facilitate the quick release of insulin, suggesting a smart drug delivery system for potential application in controlled insulin release only under hyperglycemic conditions. Finally, we demonstrated that these supramolecular nanocarriers have good cytocompatibility, which is essential for their further biomedical applications. The present study provides a novel strategy for the construction of glucose-responsive smart supramolecular drug delivery systems, which has potential applications for the treatment of diabetes mellitus. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Aerosolized liposomes with dipalmitoyl phosphatidylcholine enhance pulmonary insulin delivery.

    PubMed

    Chono, Sumio; Fukuchi, Rie; Seki, Toshinobu; Morimoto, Kazuhiro

    2009-07-20

    The pulmonary insulin delivery characteristics of liposomes were examined. Aerosolized liposomes containing insulin were administered into rat lungs and the enhancing effect on insulin delivery was evaluated by changes of plasma glucose levels. Liposomes with dipalmitoyl phosphatidylcholine (DPPC) enhanced pulmonary insulin delivery in rats, however, liposomes with dilauroyl, dimyristoyl, distearoyl or dioleoyl phosphatidylcholine did not. Liposomes with DPPC also enhanced the in vitro permeation of FITC dextran (Mw 4400, FD-4) through the calu-3 cell monolayer by reducing the transepithelial electrical resistance and did not harm lung tissues in rats. These findings suggest that liposomes with DPPC enhance pulmonary insulin delivery by opening the epithelial cell space in the pulmonary mucosa not mucosal cell damage. Liposomes with DPPC could be useful as a pulmonary delivery system for peptide and protein drugs.

  13. Current trend in drug delivery considerations for subcutaneous insulin depots to treat diabetes.

    PubMed

    P V, Jayakrishnapillai; Nair, Shantikumar V; Kamalasanan, Kaladhar

    2017-05-01

    Diabetes mellitus (DM) is a metabolic disorder due to irregularities in glucose metabolism, as a result of insulin disregulation. Chronic DM (Type 1) is treated by daily insulin injections by subcutaneous route. Daily injections cause serious patient non-compliance and medication non-adherence. Insulin Depots (ID) are parenteral formulations designed to release the insulin over a specified period of time, to control the plasma blood glucose level for intended duration. Physiologically, pancreas produces and secretes insulin in basal and pulsatile mode into the blood. Delivery systems mimicking basal release profiles are known as open-loop systems and current marketed products are open-loop systems. Future trend in open-loop systems is to reduce the number of injections per week by enhancing duration of action, by modifying the depot properties. The next generation technologies are closed-loop systems that mimic the pulsatile mode of delivery by pancreas. In closed-loop systems insulin will be released in response to plasma glucose. This review focuses on future trend in open-loop systems; by understanding (a) the secretion of insulin from pancreas, (b) the insulin regulation normal and in DM, (c) insulin depots and (d) the recent progress in open-loop depot technology particularly with respect to nanosystems. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Exploration of the Performance of a Hybrid Closed Loop Insulin Delivery Algorithm That Includes Insulin Delivery Limits Designed to Protect Against Hypoglycemia.

    PubMed

    de Bock, Martin; Dart, Julie; Roy, Anirban; Davey, Raymond; Soon, Wayne; Berthold, Carolyn; Retterath, Adam; Grosman, Benyamin; Kurtz, Natalie; Davis, Elizabeth; Jones, Timothy

    2017-01-01

    Hypoglycemia remains a risk for closed loop insulin delivery particularly following exercise or if the glucose sensor is inaccurate. The aim of this study was to test whether an algorithm that includes a limit to insulin delivery is effective at protecting against hypoglycemia under those circumstances. An observational study on 8 participants with type 1 diabetes was conducted, where a hybrid closed loop system (HCL) (Medtronic™ 670G) was challenged with hypoglycemic stimuli: exercise and an overreading glucose sensor. There was no overnight or exercise-induced hypoglycemia during HCL insulin delivery. All daytime hypoglycemia was attributable to postmeal bolused insulin in those participants with a more aggressive carbohydrate factor. HCL systems rely on accurate carbohydrate ratios and carbohydrate counting to avoid hypoglycemia. The algorithm that was tested against moderate exercise and an overreading glucose sensor performed well in terms of hypoglycemia avoidance. Algorithm refinement continues in preparation for long-term outpatient trials.

  15. Design and in vivo evaluation of a patch delivery system for insulin based on thiolated polymers.

    PubMed

    Grabovac, Vjera; Föger, Florian; Bernkop-Schnürch, Andreas

    2008-02-04

    The aim of this study was to develop and evaluate a novel three-layered oral delivery system for insulin in vivo. The patch system consisted of a mucoadhesive layer, a water insoluble backing layer made of ethylcellulose and an enteric coating made of Eudragit. Drug release studies were performed in media mimicking stomach and intestinal fluids. For in vivo studies patch systems were administered orally to conscious non-diabetic rats. Orally administered insulin in aqueous solution was used as control. After the oral administration of the patch systems a decrease of glucose and increase of insulin blood levels were measured. The mucoadhesive layer, exhibiting a diameter of 2.5mm and a weight of 5mg, comprised polycarbophil-cysteine conjugate (49%), bovine insulin (26%), gluthatione (5%) and mannitol (20%). 74.8+/-4.8% of insulin was released from the delivery system over 6h. Six hours after administration of the patch system mean maximum decrease of blood glucose level of 31.6% of the initial value could be observed. Maximum insulin concentration in blood was 11.3+/-6.2ng/ml and was reached 6h after administration. The relative bioavailability of orally administered patch system versus subcutaneous injection was 2.2%. The results indicate that the patch system provides enhancement of intestinal absorption and thereby offers a promising strategy for peroral peptide delivery.

  16. Facilitating process changes in meal delivery and radiological testing to improve inpatient insulin timing using six sigma method.

    PubMed

    Yamamoto, J Jay; Malatestinic, Bill; Lehman, Angela; Juneja, Rattan

    2010-01-01

    The objective of this project was to improve the timing of inpatient insulin administration related to meal delivery and the scheduling of radiology tests by Lean Six Sigma method. A multidisciplinary hospital team and a Six Sigma team from a pharmaceutical manufacturer collaborated to evaluate food delivery and radiology scheduling processes related to the timing of insulin administration. Key factors leading to problems within each system were addressed to improve the efficiency of each process while improving the timeliness of glucose testing and insulin administration. Standardizing the food delivery schedule and utilizing scorecards to track on-time meal deliveries to the floor enabled nursing to more accurately administer insulin in coordination with the delivery of meals. Increasing communication and restricting the scheduling of inpatient procedures during mealtimes reduced disruptions to insulin administration. Data at 6 months postimplementation demonstrated that the institution met goals for most primary outcome metrics including increasing on-time meal delivery and the proportion of patients taking insulin scheduled for radiology tests during appropriate times. By implementing the recommendations identified via Lean Six Sigma, this collaborative effort improved the timing of inpatient insulin administration related to meal delivery and radiology testing.

  17. A novel pen-based Bluetooth-enabled insulin delivery system with insulin dose tracking and advice.

    PubMed

    Bailey, Timothy S; Stone, Jenine Y

    2017-05-01

    Diabetes is growing in prevalence internationally. As more individuals require insulin as part of their treatment, technology evolves to optimize delivery, improve adherence, and reduce dosing errors. Insulin pens outperform vial and syringe in simplicity, dosing accuracy, and user preference. Bolus advisors improve dosing confidence and treatment adherence. The InPen System offers a novel approach to treatment via a wireless pen that syncs to a mobile application featuring a bolus advisor, enabling convenient insulin dose tracking and more accurate bolus advice among other features. Areas covered: Existing technology for insulin delivery and bolus advice are reviewed. The mechanics and functionality of the InPen device are delineated. Findings from formative testing and usability studies of the InPen system are reported. Future directions for the InPen system in the treatment of diabetes are discussed. Expert opinion: Diabetes management is complex and largely data-driven. The InPen System offers a promising new opportunity to avail insulin pen-users of features known to improve treatment efficacy, which have otherwise primarily been available to those using pumps. Given that the majority of insulin users do not use insulin pumps, the InPen System is poised to improve glucose control in a significant portion of the diabetes population.

  18. Gold nanorods in an oil-base formulation for transdermal treatment of type 1 diabetes in mice

    NASA Astrophysics Data System (ADS)

    Nose, Keisuke; Pissuwan, Dakrong; Goto, Masahiro; Katayama, Yoshiki; Niidome, Takuro

    2012-05-01

    Efficient transdermal insulin delivery to the systemic circulation would bring major benefit to diabetic patients. We investigated the possibility of using gold nanorods (GNRs) that formed a complex with an edible surfactant and insulin (INS) in an oil phase to form a solid-in-oil (SO) formulation (SO-INS-GNR) for transdermal treatment of diabetes. Diabetic mice comprised the model for our study. In vitro, there was high penetration of insulin through the stratum corneum (SC) and the dermis in mouse skin treated with an SO-INS-GNR complex plus near-infrared (NIR) light irradiation. Blood glucose levels in the diabetic mice were significantly decreased after treatment with SO-INS-GNR plus irradiation. To our knowledge, this is the first study to use gold nanorods for systemic insulin delivery through the skin. The use of an SO-INS-GNR complex combined with NIR irradiation may provide the possibility of transdermal insulin delivery to diabetic patients.Efficient transdermal insulin delivery to the systemic circulation would bring major benefit to diabetic patients. We investigated the possibility of using gold nanorods (GNRs) that formed a complex with an edible surfactant and insulin (INS) in an oil phase to form a solid-in-oil (SO) formulation (SO-INS-GNR) for transdermal treatment of diabetes. Diabetic mice comprised the model for our study. In vitro, there was high penetration of insulin through the stratum corneum (SC) and the dermis in mouse skin treated with an SO-INS-GNR complex plus near-infrared (NIR) light irradiation. Blood glucose levels in the diabetic mice were significantly decreased after treatment with SO-INS-GNR plus irradiation. To our knowledge, this is the first study to use gold nanorods for systemic insulin delivery through the skin. The use of an SO-INS-GNR complex combined with NIR irradiation may provide the possibility of transdermal insulin delivery to diabetic patients. Electronic supplementary information (ESI) available. See DOI: 10.1039/c2nr30651d

  19. Microparticles, microcapsules and microspheres: A review of recent developments and prospects for oral delivery of insulin.

    PubMed

    Wong, Chun Y; Al-Salami, Hani; Dass, Crispin R

    2018-02-15

    Diabetes mellitus is a chronic metabolic health disease affecting the homeostasis of blood sugar levels. However, subcutaneous injection of insulin can lead to patient non-compliance, discomfort, pain and local infection. Sub-micron sized drug delivery systems have gained attention in oral delivery of insulin for diabetes treatment. In most of the recent literature, the terms "microparticles" and "nanoparticle" refer to particles where the dimensions of the particle are measured in micrometers and nanometers respectively. For instance, insulin-loaded particles are defined as microparticles with size larger than 1 μm by most of the research groups. The size difference between nanoparticles and microparticles proffers numerous effects on the drug loading efficiency, aggregation, permeability across the biological membranes, cell entry and tissue retention. For instance, microparticulate drug delivery systems have demonstrated a number of advantages including protective effect against enzymatic degradation, enhancement of peptide stability, site-specific and controlled drug release. Compared to nanoparticulate drug delivery systems, microparticulate formulations can facilitate oral absorption of insulin by paracellular, transcellular and lymphatic routes. In this article, we review the current status of microparticles, microcapsules and microspheres for oral administration of insulin. A number of novel techniques including layer-by-layer coating, self-polymerisation of shell, nanocomposite microparticulate drug delivery system seem to be promising for enhancing the oral bioavailability of insulin. This review draws several conclusions for future directions and challenges to be addressed for optimising the properties of microparticulate drug formulations and enhancing their hypoglycaemic effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Closed-loop controlled noninvasive ultrasonic glucose sensing and insulin delivery

    NASA Astrophysics Data System (ADS)

    Park, Eun-Joo; Werner, Jacob; Jaiswal, Devina; Smith, Nadine Barrie

    2010-03-01

    To prevent complications in diabetes, the proper management of blood glucose levels is essential. Previously, ultrasonic transdermal methods using a light-weight cymbal transducer array has been studied for noninvasive methods of insulin delivery for Type-1 diabetes and glucose level monitoring. In this study, the ultrasound systems of insulin delivery and glucose sensing have been combined by a feedback controller. This study was designed to show the feasibility of the feedback controlled ultrasound system for the noninvasive glucose control. For perspective human application, in vivo experiments were performed on large animals that have a similar size to humans. Four in vivo experiments were performed using about 200 lbs pigs. The cymbal array of 3×3 pattern has been used for insulin delivery at 30 kHz with the spatial-peak temporal-peak intensity (Isptp) of 100 mW/cm2. For glucose sensing, a 2×2 array was operated at 20 kHz with Isptp = 100 mW/cm2. Based on the glucose level determined by biosensors after the ultrasound exposure, the ultrasound system for the insulin delivery was automatically operated. The glucose level of 115 mg/dl was set as a reference value for operating the insulin delivery system. For comparison, the glucose levels of blood samples collected from the ear vein were measured by a commercial glucose meter. Using the ultrasound system operated by the close-loop, feed-back controller, the glucose levels of four pigs were determined every 20 minutes and continuously controlled for 120 minutes. In comparison to the commercial glucose meter, the glucose levels determined by the biosensor were slightly higher. The results of in vivo experiments indicate the feasibility of the feedback controlled ultrasound system using the cymbal array for noninvasive glucose sensing and insulin delivery. Further studies on the extension of the glucose control will be continued for the effective method of glucose control.

  1. Skin glucose metabolism and microvascular blood flow during local insulin delivery and after an oral glucose load.

    PubMed

    Iredahl, Fredrik; Högstedt, Alexandra; Henricson, Joakim; Sjöberg, Folke; Tesselaar, Erik; Farnebo, Simon

    2016-10-01

    Insulin causes capillary recruitment in muscle and adipose tissue, but the metabolic and microvascular effects of insulin in the skin have not been studied in detail. The aim of this study was to measure glucose metabolism and microvascular blood flow in the skin during local insulin delivery and after an oral glucose load. Microdialysis catheters were inserted intracutanously in human subjects. In eight subjects two microdialysis catheters were inserted, one perfused with insulin and one with control solution. First the local effects of insulin was studied, followed by a systemic provocation by an oral glucose load. Additionally, as control experiment, six subjects did not recieve local delivery of insulin or the oral glucose load. During microdialysis the local blood flow was measured by urea clearance and by laser speckle contrast imaging (LSCI). Within 15 minutes of local insulin delivery, microvascular blood flow in the skin increased (urea clearance: P=.047, LSCI: P=.002) paralleled by increases in pyruvate (P=.01) and lactate (P=.04), indicating an increase in glucose uptake. An oral glucose load increased urea clearance from the catheters, indicating an increase in skin perfusion, although no perfusion changes were detected with LSCI. The concentration of glucose, pyruvate and lactate increased in the skin after the oral glucose load. Insulin has metabolic and vasodilatory effects in the skin both when given locally and after systemic delivery through an oral glucose load. © 2016 John Wiley & Sons Ltd.

  2. Time delay compensation for closed-loop insulin delivery systems: a simulation study.

    PubMed

    Reboldi, G P; Home, P D; Calabrese, G; Fabietti, P G; Brunetti, P; Massi Benedetti, M

    1991-06-01

    Closed loop insulin therapy certainly represents the best possible approach to insulin replacement. However, present limitations preclude wider application of the so-called artificial pancreas. Therefore, a thorough understanding of these limitations is needed to design better systems for future long-term use. The present simulation study was design: to obtain better information on the impact of the measurement delay of currently available closed-loop devices both during closed-loop insulin delivery and blood glucose clamp studies, and to design and test a time delay compensator based on the method originally described by O.J. Smith. Simulations were performed on a Compaq Deskpro 486/25 personal computer under MS-DOS operating system using Simnon rel. 3.00 software. There was a direct relationship between measurement delay and amount of insulin delivered, i.e., the longer the delay the higher the insulin dose needed to control a rise in blood glucose; the closed-loop response in presence of a time delay was qualitatively impaired both during insulin delivery and blood glucose clamp studies; time delay compensation was effective in reducing the insulin dose and improving controller stability during the early phase of clamp studies. However, the robustness of a Smith's predictor-based controller should be carefully evaluated before implementation in closed-loop systems can be considered.

  3. Can Glucose Be Monitored Accurately at the Site of Subcutaneous Insulin Delivery?

    PubMed Central

    Castle, Jessica R.; Jacobs, Peter G.; Cargill, Robert S.

    2014-01-01

    Because insulin promotes glucose uptake into adipocytes, it has been assumed that during measurement of glucose at the site of insulin delivery, the local glucose level would be much lower than systemic glucose. However, recent investigations challenge this notion. What explanations could account for a reduced local effect of insulin in the subcutaneous space? One explanation is that, in humans, the effect of insulin on adipocytes appears to be small. Another is that insulin monomers and dimers (from hexamer disassociation) might be absorbed into the circulation before they can increase glucose uptake locally. In addition, negative cooperativity of insulin action (a lower than expected effect of very high insulin concentrations)may play a contributing role. Other factors to be considered include dilution of interstitial fluid by the insulin vehicle and the possibility that some of the local decline in glucose might be due to the systemic effect of insulin. With regard to future research, redundant sensing units might be able to quantify the effects of proximity, leading to a compensatory algorithm. In summary, when measured at the site of insulin delivery, the decline in subcutaneous glucose level appears to be minimal, though the literature base is not large. Findings thus far support (1) the development of integrated devices that monitor glucose and deliver insulin and (2) the use of such devices to investigate the relationship between subcutaneous delivery of insulin and its local effects on glucose. A reduction in the number of percutaneous devices needed to manage diabetes would be welcome. PMID:24876621

  4. An injectable particle-hydrogel hybrid system for glucose-regulatory insulin delivery.

    PubMed

    Zhao, Fuli; Wu, Di; Yao, Dan; Guo, Ruiwei; Wang, Weiwei; Dong, Anjie; Kong, Deling; Zhang, Jianhua

    2017-12-01

    Long-term and daily subcutaneous injections of insulin for the treatment of insulin-dependent diabetic patients often lead to poor patient compliance and undesired complications. Phenylboronic acid (PBA)-based polymeric hydrogels have been widely considered as one of the most promising insulin delivery system to replace the frequent insulin injections. However, their applications are limited by clinically irrelevant glucose-responsive range, slow response rate, low tissue-adhesiveness and poor biodegradability, undesirable leakage at normoglycemic state. Herein, we report a novel implantable insulin hydrogel for glucose-regulated delivery of insulin based on a unique particle-hydrogel hybrid platform featuring fast glucose responsiveness at physiological pH, shear-thinning behavior for injection, tissue-adhesive function for long-lasting adherence, and full biodegradability for safe use. The system was thoroughly characterized both in vitro and in vivo and was demonstrated to hold these unique functions. Using streptozotocin-induced diabetic mice as a model, it was shown that a single subcutaneous injection of the insulin-loaded particle-hydrogel formulation led to quasi-steady-state blood glucose levels within the normal range for about two weeks. In addition, the preparation of the formulation only involved simple mixing and self-assembling processes, and thus it had great scalability and reproducibility for practical use. The highly feasible preparation, excellent performance, inherent biocompatibility and biodegradability make this novel composite hydrogel promising platform for diabetes therapy. Phenylboronic acid (PBA)-based polymeric hydrogels have been widely considered as one of the most promising insulin delivery system to replace the frequent insulin injections. However, these hydrogels, mostly based on a variety of PBA-containing acrylamide monomers, are still far from clinical reality. Building upon a unique particle-hydrogel hybrid platform, herein we report a novel implantable insulin storage and delivery system with multifunctionalities including fast glucose-sensitiveness at physiological pH, shear-thinning behavior for injection, tissue-adhesive function for long-lasting adherence, biodegradable materials for safe use and well-controlled insulin release. These unique functions were demonstrated through research both in vitro and in vivo. In addition, the preparation of the formulation was simple, and thus it had great scalability and reproducibility for practical use. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Insulin administration: present strategies and future directions for a noninvasive (possibly more physiological) delivery

    PubMed Central

    Matteucci, Elena; Giampietro, Ottavio; Covolan, Vera; Giustarini, Daniela; Fanti, Paolo; Rossi, Ranieri

    2015-01-01

    Insulin is a life-saving medication for people with type 1 diabetes, but traditional insulin replacement therapy is based on multiple daily subcutaneous injections or continuous subcutaneous pump-regulated infusion. Nonphysiologic delivery of subcutaneous insulin implies a rapid and sustained increase in systemic insulin levels due to the loss of concentration gradient between portal and systemic circulations. In fact, the liver degrades about half of the endogenous insulin secreted by the pancreas into the venous portal system. The reverse insulin distribution has short- and long-term effects on glucose metabolism. Thus, researchers have explored less-invasive administration routes based on innovative pharmaceutical formulations, which preserve hormone stability and ensure the therapeutic effectiveness. This review examines some of the recent proposals from clinical and material chemistry point of view, giving particular attention to patients’ (and diabetologists’) ideal requirements that organic chemistry could meet. PMID:26124635

  6. Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.

    PubMed

    Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon

    2010-06-01

    Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.

  7. Liposomes containing glycocholate as potential oral insulin delivery systems: preparation, in vitro characterization, and improved protection against enzymatic degradation

    PubMed Central

    Niu, Mengmeng; Lu, Yi; Hovgaard, Lars; Wu, Wei

    2011-01-01

    Background: Oral delivery of insulin is challenging and must overcome the barriers of gastric and enzymatic degradation as well as low permeation across the intestinal epithelium. The present study aimed to develop a liposomal delivery system containing glycocholate as an enzyme inhibitor and permeation enhancer for oral insulin delivery. Methods: Liposomes containing sodium glycocholate were prepared by a reversed-phase evaporation method followed by homogenization. The particle size and entrapment efficiency of recombinant human insulin (rhINS)-loaded sodium glycocholate liposomes can be easily adjusted by tuning the homogenization parameters, phospholipid:sodium glycocholate ratio, insulin:phospholipid ratio, water:ether volume ratio, interior water phase pH, and the hydration buffer pH. Results: The optimal formulation showed an insulin entrapment efficiency of 30% ± 2% and a particle size of 154 ± 18 nm. A conformational study by circular dichroism spectroscopy and a bioactivity study confirmed the preserved integrity of rhINS against preparative stress. Transmission electron micrographs revealed a nearly spherical and deformed structure with discernable lamella for sodium glycocholate liposomes. Sodium glycocholate liposomes showed better protection of insulin against enzymatic degradation by pepsin, trypsin, and α-chymotrypsin than liposomes containing the bile salt counterparts of sodium taurocholate and sodium deoxycholate. Conclusion: Sodium glycocholate liposomes showed promising in vitro characteristics and have the potential to be able to deliver insulin orally. PMID:21822379

  8. Oral insulin delivery: existing barriers and current counter-strategies.

    PubMed

    Gedawy, Ahmed; Martinez, Jorge; Al-Salami, Hani; Dass, Crispin R

    2018-02-01

    The chronic and progressive nature of diabetes is usually associated with micro- and macrovascular complications where failure of pancreatic β-cell function and a general condition of hyperglycaemia is created. One possible factor is failure of the patient to comply with and adhere to the prescribed insulin due to the inconvenient administration route. This review summarizes the rationale for oral insulin administration, existing barriers and some counter-strategies trialled. Oral insulin mimics the physiology of endogenous insulin secreted by pancreas. Following the intestinal absorption of oral insulin, it reaches the liver at high concentration via the portal vein. Oral insulin on the other hand has the potential to protect pancreatic β-cells from autoimmune destruction. Structural modification, targeting a particular tissue/receptor, and the use of innovative pharmaceutical formulations such as nanoparticles represent strategies introduced to improve oral insulin bioavailability. They showed promising results in overcoming the hurdles facing oral insulin delivery, although delivery is far from ideal. The use of advanced pharmaceutical technologies and further research in particulate carrier system delivery predominantly nanoparticle utilization would offer useful tools in delivering insulin via the oral route which in turn would potentially improve diabetic patient compliance to insulin and the overall management of diabetes. © 2017 Royal Pharmaceutical Society.

  9. pH-sensitive thiolated nanoparticles facilitate the oral delivery of insulin in vitro and in vivo

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Lin, Xia; Du, Xuli; Geng, Sicong; Li, Hongren; Sun, Hong; Tang, Xing; Xiao, Wei

    2015-02-01

    In this work, we designed and developed a delivery system composed of enteric Eudragit L100-cysteine/reduced glutathione nanoparticles (Eul-cys/GSH NPs) for oral delivery of insulin. First, interactions between Eul-cys and mucin glycoproteins, which are believed to be the result of disulfide bonds, were confirmed using rheology experiments. Subsequently, the insulin-loaded Eul-cys/GSH NPs were prepared by the diffusion method using the rich gel network multipore structure at the surface of the Eul-cys when the pH was higher than the p Ka of Eul-cys polymer. The Eul-cys/GSH NPs obtained were characterized by dynamic light scattering, transmission electron microscopy, and atomic force microscopy. The results obtained showed that the average particle size ranged from 240 to 280 nm, and the particles were almost spherical in shape. The in vitro drug release results showed that the Eul-cys/GSH NPs retained a large amount of insulin in simulated gastric fluid, while a significant insulin release was found in simulated intestinal fluid. The in situ release study suggested that NPs released a greater amount of FITC-insulin (49.2 %) into the intestinal mucus layer compared with that of FITC-insulin solution (16.4 %), which facilitating insulin delivery through the intestinal mucosa. Eul-cys/GSH NPs exhibited promising mucoadhesive properties demonstrated using an in vitro cell model. Consequently, NPs were introduced into the ileum loop of healthy rats, thus enhancing the intestinal absorption of insulin and providing a prolonged reduction in blood glucose levels. These results suggest that Eul-cys/GSH NPs may be a promising delivery system for the treatment of diabetes.

  10. Development of glucose-responsive 'smart' insulin systems.

    PubMed

    Rege, Nischay K; Phillips, Nelson F B; Weiss, Michael A

    2017-08-01

    The complexity of modern insulin-based therapy for type I and type II diabetes mellitus and the risks associated with excursions in blood-glucose concentration (hyperglycemia and hypoglycemia) have motivated the development of 'smart insulin' technologies (glucose-responsive insulin, GRI). Such analogs or delivery systems are entities that provide insulin activity proportional to the glycemic state of the patient without external monitoring by the patient or healthcare provider. The present review describes the relevant historical background to modern GRI technologies and highlights three distinct approaches: coupling of continuous glucose monitoring (CGM) to deliver devices (algorithm-based 'closed-loop' systems), glucose-responsive polymer encapsulation of insulin, and molecular modification of insulin itself. Recent advances in GRI research utilizing each of the three approaches are illustrated; these include newly developed algorithms for CGM-based insulin delivery systems, glucose-sensitive modifications of existing clinical analogs, newly developed hypoxia-sensitive polymer matrices, and polymer-encapsulated, stem-cell-derived pancreatic β cells. Although GRI technologies have yet to be perfected, the recent advances across several scientific disciplines that are described in this review have provided a path towards their clinical implementation.

  11. Advances in bioresponsive closed-loop drug delivery systems.

    PubMed

    Yu, Jicheng; Zhang, Yuqi; Yan, Junjie; Kahkoska, Anna R; Gu, Zhen

    2017-11-27

    Controlled drug delivery systems are able to improve efficacy and safety of therapeutics by optimizing the duration and kinetics of release. Among them, closed-loop delivery strategies, also known as self-regulated administration, have proven to be a practical tool for homeostatic regulation, by tuning drug release as a function of biosignals relevant to physiological and pathological processes. A typical example is glucose-responsive insulin delivery system, which can mimic the pancreatic beta cells to release insulin with a proper dose at a proper time point by responding to plasma glucose levels. Similar self-regulated systems are also important in the treatment of other diseases including thrombosis and bacterial infection. In this review, we survey the recent advances in bioresponsive closed-loop drug delivery systems, including glucose-responsive, enzyme-activated, and other biosignal-mediated delivery systems. We also discuss the future opportunities and challenges in this field. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Chitosan-sodium lauryl sulfate nanoparticles as a carrier system for the in vivo delivery of oral insulin.

    PubMed

    Elsayed, Amani; Al-Remawi, Mayyas; Qinna, Nidal; Farouk, Asim; Al-Sou'od, Khaldoun A; Badwan, Adnan A

    2011-09-01

    The present work explores the possibility of formulating an oral insulin delivery system using nanoparticulate complexes made from the interaction between biodegradable, natural polymer called chitosan and anionic surfactant called sodium lauryl sulfate (SLS). The interaction between chitosan and SLS was confirmed by Fourier transform infrared spectroscopy. The nanoparticles were prepared by simple gelation method under aqueous-based conditions. The nanoparticles were stable in simulated gastric fluids and could protect the encapsulated insulin from the GIT enzymes. Additionally, the in vivo results clearly indicated that the insulin-loaded nanoparticles could effectively reduce the blood glucose level in a diabetic rat model. However, additional formulation modifications are required to improve insulin oral bioavailability.

  13. A coordinated control strategy for insulin and glucagon delivery in type 1 diabetes.

    PubMed

    Herrero, Pau; Bondia, Jorge; Oliver, Nick; Georgiou, Pantelis

    2017-10-01

    Type 1 diabetes is an autoimmune condition characterised by a pancreatic insulin secretion deficit, resulting in high blood glucose concentrations, which can lead to micro- and macrovascular complications. Type 1 diabetes also leads to impaired glucagon production by the pancreatic α-cells, which acts as a counter-regulatory hormone to insulin. A closed-loop system for automatic insulin and glucagon delivery, also referred to as an artificial pancreas, has the potential to reduce the self-management burden of type 1 diabetes and reduce the risk of hypo- and hyperglycemia. To date, bihormonal closed-loop systems for glucagon and insulin delivery have been based on two independent controllers. However, in physiology, the secretion of insulin and glucagon in the body is closely interconnected by paracrine and endocrine associations. In this work, we present a novel biologically-inspired glucose control strategy that accounts for such coordination. An in silico study using an FDA-accepted type 1 simulator was performed to evaluate the proposed coordinated control strategy compared to its non-coordinated counterpart, as well as an insulin-only version of the controller. The proposed coordinated strategy achieves a reduction of hyperglycemia without increasing hypoglycemia, when compared to its non-coordinated counterpart.

  14. New-generation diabetes management: glucose sensor-augmented insulin pump therapy

    PubMed Central

    Cengiz, Eda; Sherr, Jennifer L; Weinzimer, Stuart A; Tamborlane, William V

    2011-01-01

    Diabetes is one of the most common chronic disorders with an increasing incidence worldwide. Technologic advances in the field of diabetes have provided new tools for clinicians to manage this challenging disease. For example, the development of continuous subcutaneous insulin infusion systems have allowed for refinement in the delivery of insulin, while continuous glucose monitors provide patients and clinicians with a better understanding of the minute to minute glucose variability, leading to the titration of insulin delivery based on this variability when applicable. Merging of these devices has resulted in sensor-augmented insulin pump therapy, which became a major building block upon which the artificial pancreas (closed-loop systems) can be developed. This article summarizes the evolution of sensor-augmented insulin pump therapy until present day and its future applications in new-generation diabetes management. PMID:21728731

  15. New-generation diabetes management: glucose sensor-augmented insulin pump therapy.

    PubMed

    Cengiz, Eda; Sherr, Jennifer L; Weinzimer, Stuart A; Tamborlane, William V

    2011-07-01

    Diabetes is one of the most common chronic disorders with an increasing incidence worldwide. Technologic advances in the field of diabetes have provided new tools for clinicians to manage this challenging disease. For example, the development of continuous subcutaneous insulin infusion systems have allowed for refinement in the delivery of insulin, while continuous glucose monitors provide patients and clinicians with a better understanding of the minute to minute glucose variability, leading to the titration of insulin delivery based on this variability when applicable. Merging of these devices has resulted in sensor-augmented insulin pump therapy, which became a major building block upon which the artificial pancreas (closed-loop systems) can be developed. This article summarizes the evolution of sensor-augmented insulin pump therapy until present day and its future applications in new-generation diabetes management.

  16. Insulin delivery and nocturnal glucose control in children and adolescents with type 1 diabetes.

    PubMed

    Tauschmann, Martin; Hovorka, Roman

    2017-12-01

    Nocturnal glucose control remains challenging in children and adolescents with type 1 diabetes due to highly variable overnight insulin requirements. The issue may be addressed by glucose responsive insulin delivery based on real-time continuous glucose measurements. Areas covered: This review outlines recent developments of glucose responsive insulin delivery systems from a paediatric perspective. We cover threshold-based suspend application, predictive low glucose suspend, and more advanced single hormone and dual-hormone closed-loop systems. Approaches are evaluated in relation to nocturnal glucose control particularly during outpatient randomised controlled trials. Expert opinion: Significant progress translating research from controlled clinical centre settings to free-living unsupervised home studies have been achieved over the past decade. Nocturnal glycaemic control can be improved whilst reducing the risk of hypoglycaemia with closed-loop systems. Following the US regulatory approval of the first hybrid closed-loop system in non-paediatric population, large multinational closed-loop clinical trials and pivotal studies including paediatric populations are underway or in preparation to facilitate the use of closed-loop systems in clinical practice.

  17. Concanavalin A conjugated biodegradable nanoparticles for oral insulin delivery

    NASA Astrophysics Data System (ADS)

    Hurkat, Pooja; Jain, Aviral; Jain, Ashish; Shilpi, Satish; Gulbake, Arvind; Jain, Sanjay K.

    2012-11-01

    Major research issues in oral protein delivery include the stabilization of protein in delivery devices which could increase its oral bioavailability. The study deals with development of oral insulin delivery system utilizing biodegradable poly(lactic-co-glycolic acid) (PLGA) nanoparticles and modifying its surface with Concanavalin A to increase lymphatic uptake. Surface-modified PLGA nanoparticles were characterized for conjugation efficiency of ligand, shape and surface morphology, particle size, zeta potential, polydispersity index, entrapment efficiency, and in vitro drug release. Stability of insulin in the developed formulation was confirmed by SDS-PAGE, and integrity of entrapped insulin was assessed using circular dichroism spectrum. Ex vivo study was performed on Wistar rats, which exhibited the higher intestinal uptake of Con A conjugated nanoparticles. In vivo study performed on streptozotocin-induced diabetic rats which indicate that a surface-modified nanoparticle reduces blood glucose level effectively within 4 h of its oral administration. In conclusion, the present work resulted in successful production of Con A NPs bearing insulin with sustained release profile, and better absorption and stability. The Con A NPs showed high insulin uptake, due to its relative high affinity for non-reducing carbohydrate residues i.e., fucose present on M cells and have the potential for oral insulin delivery in effective management of Type 1 diabetes condition.

  18. Electrostatic Self-Assembled Chitosan-Pectin Nano- and Microparticles for Insulin Delivery.

    PubMed

    Maciel, Vinicius B V; Yoshida, Cristiana M P; Pereira, Susana M S S; Goycoolea, Francisco M; Franco, Telma T

    2017-10-12

    A polyelectrolyte complex system of chitosan-pectin nano- and microparticles was developed to encapsulate the hormone insulin. The aim of this work was to obtain small particles for oral insulin delivery without chemical crosslinkers based on natural and biodegradable polysaccharides. The nano- and microparticles were developed using chitosans (with different degrees of acetylation: 15.0% and 28.8%) and pectin solutions at various charge ratios (n⁺/n - given by the chitosan/pectin mass ratio) and total charge. Nano- and microparticles were characterized regarding particle size, zeta potential, production yield, encapsulation efficiency, stability in different media, transmission electron microscopy and cytotoxicity assays using Caco-2 cells. The insulin release was evaluated in vitro in simulated gastric and intestinal media. Small-sized particles (~240-~1900 nm) with a maximum production yield of ~34.0% were obtained. The highest encapsulation efficiency (~62.0%) of the system was observed at a charge ratio (n⁺/n - ) 5.00. The system was stable in various media, particularly in simulated gastric fluid (pH 1.2). Transmission electron microscopy (TEM) analysis showed spherical shape particles when insulin was added to the system. In simulated intestinal fluid (pH 6.8), controlled insulin release occurred over 2 h. In vitro tests indicated that the proposed system presents potential as a drug delivery for oral administration of bioactive peptides.

  19. Solid lipid nanoparticles as insulin inhalation carriers for enhanced pulmonary delivery.

    PubMed

    Bi, Ru; Shao, Wei; Wang, Qun; Zhang, Na

    2009-02-01

    Growing attentions have been paid to the pulmonary route for systemic delivery of peptide and protein drugs, such as insulin. Advantages of this non-injective route include rapid drug deposition in the target organ, fewer systemic side effects and avoiding first pass metabolism. However, sustained release formulations for pulmonary delivery have not been fully exploited till now. In our study, a novel dry powder inhalation (DPI) system of insulin loaded solid lipid nanoparticles (Ins-SLNs) was investigated for prolonged drug release, improved stability and effective inhalation. Firstly, the drug was incorporated into the lipid carriers for a maximum entrapment efficiency as high as 69.47 +/- 3.27% (n = 3). Secondly, DPI formulation was prepared by spray freeze drying of Ins-SLNs suspension, with optimized lyoprotectant and technique parameters in this procedure. The properties of DPI particles were characterized for their pulmonary delivery potency. Thirdly, the in vivo study of intratracheal instillation of Ins-SLNs to diabetic rats showed prolonged hypoglycemic effect and a relative pharmacological bioavailability of 44.40% could be achieved in the group of 8 IU/kg dosage. These results indicated that SLNs have shown increasing potential as an efficient and non-toxic lipophilic colloidal drug carrier for enhanced pulmonary delivery of insulin.

  20. Electroreleasing Composite Membranes for Delivery of Insulin and Other Biomacromolecules

    DTIC Science & Technology

    1990-04-05

    electrochemistry to control the delivery of a chemical or drug (1, 2). The major advantage of electroreleasing systems (over conventional diffusional drug...used to deliver insulin and vitamin B-12. The composite membrane fabrication procedure is shown schematically in Figure 1. An Anopore ( Alltech ) A1203

  1. Closing the loop.

    PubMed

    Dassau, E; Atlas, E; Phillip, M

    2010-02-01

    The dream of closing the loop is actually the dream of creating an artificial pancreas and freeing the patients from being involved with the care of their own diabetes. Insulin-dependent diabetes (type 1) is a chronic incurable disease which requires constant therapy without the possibility of any 'holidays' or insulin-free days. It means that patients have to inject insulin every day of their life, several times per day, and in order to do it safely they also have to measure their blood glucose levels several times per day. Patients need to plan their meals, their physical activities and their insulin regime - there is only very small room for spontaneous activities. This is why the desire for an artificial pancreas is so strong despite the fact that it will not cure the diabetic patients. Attempts to develop a closed-loop system started in the 1960s but never got to a clinical practical stage of development. In recent years the availability of continuous glucose sensors revived those efforts and stimulated the clinician and researchers to believe that closing the loop might be possible nowadays. Many papers have been published over the years describing several different ideas on how to close the loop. Most of the suggested systems have a sensing arm that measures the blood glucose repeatedly or continuously, an insulin delivery arm that injects insulin upon command and a computer that makes the decisions of when and how much insulin to deliver. The differences between the various published systems in the literature are mainly in their control algorithms. However, there are also differences related to the method and site of glucose measurement and insulin delivery. SC glucose measurements and insulin delivery are the most studied option but other combinations of insulin measurements and glucose delivery including intravascular and intraperitoneal (IP) are explored. We tried to select recent publications that we believe had influenced and inspired people interested in the field.

  2. Chitosan/lecithin liposomal nanovesicles as an oral insulin delivery system.

    PubMed

    Al-Remawi, Mayyas; Elsayed, Amani; Maghrabi, Ibrahim; Hamaidi, Mohammad; Jaber, Nisrein

    2017-05-01

    In the present work, insulin-chitosan polyelectrolyte complexes associated to lecithin liposomes were investigated as a new carrier for oral delivery of insulin. The preparation was characterized in terms of particle size, zeta potential and encapsulation efficiency. Surface tension measurements revealed that insulin-chitosan polyelectrolyte complexes have some degree of hydrophobicity and should be added to lecithin liposomal dispersion and not the vice versa to prevent their adsorption on the surface. Stability of insulin was enhanced when it was associated to liposomes. Significant reduction of blood glucose levels was noticed after oral administration of liposomal preparation to streptozotocin diabetic rats compared to control. The hypoglycemic activity was more prolonged compared to subcutaneously administered insulin.

  3. Glucagon-Like Peptide 1 Recruits Muscle Microvasculature and Improves Insulin’s Metabolic Action in the Presence of Insulin Resistance

    PubMed Central

    Chai, Weidong; Zhang, Xingxing; Barrett, Eugene J.

    2014-01-01

    Glucagon-like peptide 1 (GLP-1) acutely recruits muscle microvasculature, increases muscle delivery of insulin, and enhances muscle use of glucose, independent of its effect on insulin secretion. To examine whether GLP-1 modulates muscle microvascular and metabolic insulin responses in the setting of insulin resistance, we assessed muscle microvascular blood volume (MBV), flow velocity, and blood flow in control insulin-sensitive rats and rats made insulin-resistant acutely (systemic lipid infusion) or chronically (high-fat diet [HFD]) before and after a euglycemic-hyperinsulinemic clamp (3 mU/kg/min) with or without superimposed systemic GLP-1 infusion. Insulin significantly recruited muscle microvasculature and addition of GLP-1 further expanded muscle MBV and increased insulin-mediated glucose disposal. GLP-1 infusion potently recruited muscle microvasculature in the presence of either acute or chronic insulin resistance by increasing muscle MBV. This was associated with an increased muscle delivery of insulin and muscle interstitial oxygen saturation. Muscle insulin sensitivity was completely restored in the presence of systemic lipid infusion and significantly improved in rats fed an HFD. We conclude that GLP-1 infusion potently expands muscle microvascular surface area and improves insulin’s metabolic action in the insulin-resistant states. This may contribute to improved glycemic control seen in diabetic patients receiving incretin-based therapy. PMID:24658303

  4. Simultaneous expression and transportation of insulin by supramolecular polysaccharide nanocluster

    NASA Astrophysics Data System (ADS)

    Zhang, Yu-Hui; Zhang, Ying-Ming; Zhao, Qi-Hui; Liu, Yu

    2016-03-01

    Drug/gene transportation systems with stimuli-responsive release behaviors are becoming research hotspots in biochemical and biomedical fields. In this work, a glucose-responsive supramolecular nanocluster was successfully constructed by the intermolecular complexation of phenylboronic acid modified β-cyclodextrin with adamantane modified polyethylenimine, which could be used as a biocompatible carrier for insulin and pCMV3-C-GFPSpark-Ins DNA which could express insulin co-delivery. Benefiting from the response capability of phenylboronic acid moiety toward glucose, the encapsulated insulin could be specifically released and the corresponding targeted DNA could efficiently express insulin in HepG2 cell, accompanied by the high-level insulin release in vitro. Our results demonstrate that the simultaneous insulin drug delivery and insulin gene transfection in a controlled mode may have great potential in the clinical diabetes treatments.

  5. May maternal lifestyle have an impact on neonatal glucose levels?

    PubMed

    Hoirisch-Clapauch, Silvia; Porto, Maria Amelia S; Nardi, Antonio E

    2016-02-01

    Neonatal glucose levels correlate negatively with umbilical cord levels of C-peptide, a polypeptide secreted with insulin. In other words, neonatal hypoglycemia results from excessive insulin secretion from fetal/neonatal beta cells. Given that insulin causes fat to be stored rather than to be used for energy, one would expect that chronic hyperinsulinemia would result in large-for-gestational-age neonates. The finding that many small-for-gestational-age neonates have hypoglycemia suggests that the stimulus for insulin production occurs close to delivery. We postulated that a potent stimulation of maternal insulin production close to delivery would also provide a potent stimulus for fetal and neonatal insulin production, causing neonatal hypoglycemia. This study has evaluated 155 mothers with markers of excessive insulin production (such as acanthosis or grade III obesity), or with situations characterized by increased insulin requirements (such as an invasive bacterial infection or use of systemic corticosteroid within a week before delivery; or sedentariness or high-carbohydrate intake within 24h before delivery) and their 158 neonates who were screened for glycemic levels at 1, 2 and 4h after birth. The minimum glucose level was correlated to the maternal parameters, and to classical predictors of neonatal hypoglycemia, such as low-birth weight and preterm delivery. The only independent predictors were sedentariness and high-carbohydrate intake within 24h before delivery. The risk of neonatal hypoglycemia increased five-fold with sedentariness, 11-fold with high-carbohydrate intake, and 329-fold with both risk factors. The risk of neonatal hypoglycemia seems to be highly influenced by maternal lifestyle within 24h before delivery. Controlled randomized trials may help determine whether a controlled carbohydrate diet combined with regular physical activity close to delivery can prevent neonatal hypoglycemia and all its severe complications to the newborn. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Chitosan-modified porous silicon microparticles for enhanced permeability of insulin across intestinal cell monolayers.

    PubMed

    Shrestha, Neha; Shahbazi, Mohammad-Ali; Araújo, Francisca; Zhang, Hongbo; Mäkilä, Ermei M; Kauppila, Jussi; Sarmento, Bruno; Salonen, Jarno J; Hirvonen, Jouni T; Santos, Hélder A

    2014-08-01

    Porous silicon (PSi) based particulate systems are emerging as an important drug delivery system due to its advantageous properties such as biocompatibility, biodegradability and ability to tailor the particles' physicochemical properties. Here, annealed thermally hydrocarbonized PSi (AnnTHCPSi) and undecylenic acid modified AnnTHCPSi (AnnUnTHCPSi) microparticles were developed as a PSi-based platform for oral delivery of insulin. Chitosan (CS) was used to modify the AnnUnTHCPSi microparticles to enhance the intestinal permeation of insulin. Surface modification with CS led to significant increase in the interaction of PSi microparticles with Caco-2/HT-29 cell co-culture monolayers. Compared to pure insulin, the CS-conjugated microparticles significantly improved the permeation of insulin across the Caco-2/HT-29 cell monolayers, with ca. 20-fold increase in the amount of insulin permeated and ca. 7-fold increase in the apparent permeability (P(app)) value. Moreover, among all the investigated particles, the CS-conjugated microparticles also showed the highest amount of insulin associated with the mucus layer and the intestinal Caco-2 cells and mucus secreting HT-29 cells. Our results demonstrate that CS-conjugated AnnUnTHCPSi microparticles can efficiently enhance the insulin absorption across intestinal cells, and thus, they are promising microsystems for the oral delivery of proteins and peptides across the intestinal cell membrane. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Pharmacological and toxicological assessment of innovative self-assembled polymeric micelles as powders for insulin pulmonary delivery.

    PubMed

    Andrade, Fernanda; Fonte, Pedro; Costa, Ana; Reis, Cassilda Cunha; Nunes, Rute; Almeida, Andreia; Ferreira, Domingos; Oliva, Mireia; Sarmento, Bruno

    2016-09-01

    Explore the use of polymeric micelles in the development of powders intended for pulmonary delivery of biopharmaceuticals, using insulin as a model protein. Formulations were assessed in vitro for aerosolization properties and in vivo for efficacy and safety using a streptozotocin-induced diabetic rat model. Powders presented good aerosolization properties like fine particle fraction superior to 40% and a mass median aerodynamic diameter inferior of 6 μm. Endotracheally instilled powders have shown a faster onset of action than subcutaneous administration of insulin at a dose of 10 IU/kg, with pharmacological availabilities up to 32.5% of those achieved by subcutaneous route. Additionally, micelles improved the hypoglycemic effect of insulin. Bronchoalveolar lavage screening for toxicity markers (e.g., lactate dehydrogenase, cytokines) revealed no signs of lung inflammation and cytotoxicity 14 days postadministration. Developed powders showed promising safety and efficacy characteristics for the systemic delivery of insulin by pulmonary administration.

  8. Hypoxia and H2O2 Dual-Sensitive Vesicles for Enhanced Glucose-Responsive Insulin Delivery.

    PubMed

    Yu, Jicheng; Qian, Chenggen; Zhang, Yuqi; Cui, Zheng; Zhu, Yong; Shen, Qundong; Ligler, Frances S; Buse, John B; Gu, Zhen

    2017-02-08

    A glucose-responsive closed-loop insulin delivery system mimicking pancreas activity without long-term side effect has the potential to improve diabetic patients' health and quality of life. Here, we developed a novel glucose-responsive insulin delivery device using a painless microneedle-array patch containing insulin-loaded vesicles. Formed by self-assembly of hypoxia and H 2 O 2 dual-sensitive diblock copolymer, the glucose-responsive polymersome-based vesicles (d-GRPs) can disassociate and subsequently release insulin triggered by H 2 O 2 and hypoxia generated during glucose oxidation catalyzed by glucose specific enzyme. Moreover, the d-GRPs were able to eliminate the excess H 2 O 2 , which may lead to free radical-induced damage to skin tissue during the long-term usage and reduce the activity of GOx. In vivo experiments indicated that this smart insulin patch could efficiently regulate the blood glucose in the chemically induced type 1 diabetic mice for 10 h.

  9. Insulin Patch Pumps: Their Development and Future in Closed-Loop Systems

    PubMed Central

    Bohannon, Nancy J.V.

    2010-01-01

    Abstract Steady progress is being made toward the development of a so-called “artificial pancreas,” which may ultimately be a fully automated, closed-loop, glucose control system comprising a continuous glucose monitor, an insulin pump, and a controller. The controller will use individualized algorithms to direct delivery of insulin without user input. A major factor propelling artificial pancreas development is the substantial incidence of—and attendant patient, parental, and physician concerns about—hypoglycemia and extreme hyperglycemia associated with current means of insulin delivery for type 1 diabetes mellitus (T1DM). A successful fully automated artificial pancreas would likely reduce the frequency of and anxiety about hypoglycemia and marked hyperglycemia. Patch-pump systems (“patch pumps”) are likely to be used increasingly in the control of T1DM and may be incorporated into the artificial pancreas systems of tomorrow. Patch pumps are free of tubing, small, lightweight, and unobtrusive. This article describes features of patch pumps that have been approved for U.S. marketing or are under development. Included in the review is an introduction to control algorithms driving insulin delivery, particularly the two major types: proportional integrative derivative and model predictive control. The use of advanced algorithms in the clinical development of closed-loop systems is reviewed along with projected next steps in artificial pancreas development. PMID:20515308

  10. Comparison of standard (self-directed) versus intensive patient training for the human insulin inhalation powder (HIIP) delivery system in patients with type 2 diabetes: efficacy, safety, and training measures.

    PubMed

    Rosenstock, Julio; Nakano, Masako; Silverman, Bernard L; Sun, Bin; de la Peña, Amparo; Suri, Ajit; Muchmore, Douglas B

    2007-02-01

    The Lilly/Alkermes human insulin inhalation powder (HIIP) delivery system [AIR (a registered trademark of Alkermes, Inc., Cambridge, MA) Inhaled Insulin System] was designed to be easy to use. Training methods were compared in insulin-naive patients with type 2 diabetes. Patients (n = 102) were randomized to standard or intensive training. With standard training, patients learned how to use the HIIP delivery system by reading directions for use (DFU) and trying on their own. Intensive training included orientation to the HIIP delivery system with individual coaching and inspiratory flow rate training. Both groups received preprandial HIIP + metformin with or without a thiazolidinedione for 4 weeks. Overall 2-h postprandial blood glucose (PPBG) excursion was the primary measure. Noninferiority was defined as the upper limit of the two-sided 95% confidence interval of the mean difference between groups being 1.2 < or = mmol/L. Overall 2-h PPBG excursions (least squares mean +/- SE) at endpoint were -0.11 +/- 0.38 (standard training) and 0.23 +/- 0.36 (intensive training) mmol/L. The mean difference (standard minus intensive training) and two-sided 95% confidence interval were -0.35 (-1.02, 0.33) mmol/L. No statistically or clinically significant differences were observed between training methods in premeal, postmeal, or bedtime blood glucose values, HIIP doses at endpoint, or blood glucose values after a test meal. No discontinuations occurred because of difficulty of use or dislike of the HIIP system. DFU compliance was >90% in both training groups. There were no significant differences between training methods in safety measures. The HIIP delivery system is easy to use, and most patients can learn to use it by reading the DFU without assistance from health care professionals.

  11. Ultrasound mediated transdermal insulin delivery in pigs using a lightweight transducer.

    PubMed

    Park, E J; Werner, Jacob; Smith, Nadine Barrie

    2007-07-01

    In previous studies, ultrasound mediated transdermal drug delivery has shown a promising potential as a method for noninvasive drug administration. For prospective future human application, this study was designed to determine the feasibility of lightweight cymbal transducer array as a practical device for noninvasive transdermal insulin delivery in large pigs. Six Yorkshire pigs (100-140 lbs) were divided into two groups. As the control (n = 3), the first group did not receive any ultrasound exposure with the insulin. The second group (n = 3) was treated with ultrasound and insulin at 20 kHz with an I(sptp) = 100 mW/cm(2) at a 20% duty cycle for 60 min. With the pigs in lateral recumbency after anesthesia, the ultrasound transducer with insulin was placed on the axillary area of the pig. At the beginning and every 15 min up to 90 min, the blood glucose level was determined using a glucose monitoring system. To compare the results of individual animals, the change of blood glucose level was normalized to each animal's initial glucose value at the start of the experiment. Although each animal had a different initial glucose level, the mean and standard error for the six animals was 146 +/- 13 mg/dl. For the control group, the blood glucose level increased to 31 +/- 21 mg/dl compared to the initial baseline over the 90 min experiment. However for the ultrasound with insulin treated group, the glucose level decreased to -72 +/- 5 mg/dl at 60 min (p < 0.05) and continued to decrease to -91 +/- 23 mg/dl in 90 min (p < 0.05). The results indicate the feasibility of ultrasound mediated transdermal insulin delivery using the cymbal transducer array in animal with a similar size and weight to a human. Based on these result, the cymbal array has potential as a practical ultrasound system for noninvasive transdermal insulin delivery for diabetes management.

  12. Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes

    PubMed Central

    Castle, Jessica R.; Engle, Julia M.; Youssef, Joseph El; Massoud, Ryan G.; Yuen, Kevin C.J.; Kagan, Ryland; Ward, W. Kenneth

    2010-01-01

    OBJECTIVE To minimize hypoglycemia in subjects with type 1 diabetes by automated glucagon delivery in a closed-loop insulin delivery system. RESEARCH DESIGN AND METHODS Adult subjects with type 1 diabetes underwent one closed-loop study with insulin plus placebo and one study with insulin plus glucagon, given at times of impending hypoglycemia. Seven subjects received glucagon using high-gain parameters, and six subjects received glucagon in a more prolonged manner using low-gain parameters. Blood glucose levels were measured every 10 min and insulin and glucagon infusions were adjusted every 5 min. All subjects received a portion of their usual premeal insulin after meal announcement. RESULTS Automated glucagon plus insulin delivery, compared with placebo plus insulin, significantly reduced time spent in the hypoglycemic range (15 ± 6 vs. 40 ± 10 min/day, P = 0.04). Compared with placebo, high-gain glucagon delivery reduced the frequency of hypoglycemic events (1.0 ± 0.6 vs. 2.1 ± 0.6 events/day, P = 0.01) and the need for carbohydrate treatment (1.4 ± 0.8 vs. 4.0 ± 1.4 treatments/day, P = 0.01). Glucagon given with low-gain parameters did not significantly reduce hypoglycemic event frequency (P = NS) but did reduce frequency of carbohydrate treatment (P = 0.05). CONCLUSIONS During closed-loop treatment in subjects with type 1 diabetes, high-gain pulses of glucagon decreased the frequency of hypoglycemia. Larger and longer-term studies will be required to assess the effect of ongoing glucagon treatment on overall glycemic control. PMID:20332355

  13. Glucose-responsive microgels integrated with enzyme nanocapsules for closed-loop insulin delivery.

    PubMed

    Gu, Zhen; Dang, Tram T; Ma, Minglin; Tang, Benjamin C; Cheng, Hao; Jiang, Shan; Dong, Yizhou; Zhang, Yunlong; Anderson, Daniel G

    2013-08-27

    A glucose-responsive closed-loop insulin delivery system represents the ideal treatment of type 1 diabetes mellitus. In this study, we develop uniform injectable microgels for controlled glucose-responsive release of insulin. Monodisperse microgels (256 ± 18 μm), consisting of a pH-responsive chitosan matrix, enzyme nanocapsules, and recombinant human insulin, were fabricated through a one-step electrospray procedure. Glucose-specific enzymes were covalently encapsulated into the nanocapsules to improve enzymatic stability by protecting from denaturation and immunogenicity as well as to minimize loss due to diffusion from the matrix. The microgel system swelled when subjected to hyperglycemic conditions, as a result of the enzymatic conversion of glucose into gluconic acid and protonation of the chitosan network. Acting as a self-regulating valve system, microgels were adjusted to release insulin at basal release rates under normoglycemic conditions and at higher rates under hyperglycemic conditions. Finally, we demonstrated that these microgels with enzyme nanocapsules facilitate insulin release and result in a reduction of blood glucose levels in a mouse model of type 1 diabetes.

  14. FACTORS AFFECTING THE DEPOSITION OF AEROSOLIZED INSULIN

    EPA Science Inventory

    Abstract
    Background
    The inhalation of insulin for absorption into the bloodstream via the lung seems to be a promising technique for the treatment of diabetes mellitus. A fundamental issue to be resolved in the development of such insulin aerosol delivery systems is their...

  15. Losartan increases muscle insulin delivery and rescues insulin's metabolic action during lipid infusion via microvascular recruitment

    PubMed Central

    Wang, Nasui; Chai, Weidong; Zhao, Lina; Tao, Lijian; Cao, Wenhong

    2013-01-01

    Insulin delivery and transendothelial insulin transport are two discrete steps that limit muscle insulin action. Angiotensin II type 1 receptor (AT1R) blockade recruits microvasculature and increases glucose use in muscle. Increased muscle microvascular perfusion is associated with increased muscle delivery and action of insulin. To examine the effect of acute AT1R blockade on muscle insulin uptake and action, rats were studied after an overnight fast to examine the effects of losartan on muscle insulin uptake (protocol 1), microvascular perfusion (protocol 2), and insulin's microvascular and metabolic actions in the state of insulin resistance (protocol 3). Endothelial cell insulin uptake was assessed, using 125I-insulin as tracer. Systemic lipid infusion was used to induce insulin resistance. Losartan significantly increased muscle insulin uptake (∼60%, P < 0.03), which was associated with a two- to threefold increase in muscle microvascular blood volume (MBV; P = 0.002) and flow (MBF; P = 0.002). Losartan ± angiotensin II had no effect on insulin internalization in cultured endothelial cells. Lipid infusion abolished insulin-mediated increases in muscle MBV and MBF and lowered insulin-stimulated whole body glucose disposal (P = 0.0001), which were reversed by losartan administration. Inhibition of nitric oxide synthase abolished losartan-induced muscle insulin uptake and reversal of lipid-induced metabolic insulin resistance. We conclude that AT1R blockade increases muscle insulin uptake mainly via microvascular recruitment and rescues insulin's metabolic action in the insulin-resistant state. This may contribute to the clinical findings of decreased cardiovascular events and new onset of diabetes in patients receiving AT1R blockers. PMID:23299501

  16. Exubera® (inhaled insulin): an evidence-based review of its effectiveness in the management of diabetes

    PubMed Central

    Profit, Louise

    2005-01-01

    Introduction: Inadequate glycemic control contributes to the development and progression of complications, which are associated with a significant economic burden on healthcare systems. However, optimal glycemic control is difficult to sustain with oral antidiabetic agents and adherence to intensive insulin regimens is compromised by patient compliance to multiple daily injections. Therefore, alternative delivery systems are required to improve the acceptability of insulin therapy. Aims: This review assesses the evidence for the therapeutic value of inhaled insulin (Exubera®) in the management of type 1 and type 2 diabetes. Evidence review: Evidence indicates that glycemic control, as measured by plasma HbA1c levels, with Exubera is as effective as subcutaneous insulin in patients with type 1 or type 2 diabetes. There is also good evidence that Exubera provides improved patient satisfaction and ease of use compared with subcutaneous insulin. However, the cost effectiveness of Exubera and its place in therapy compared with other inhaled insulin delivery systems currently in development remain to be determined. Outcomes summary: Exubera is an alternative treatment option for the management of diabetes which provides effective glycemic control with improved patient satisfaction. PMID:22500147

  17. Biological assessment of self-assembled polymeric micelles for pulmonary administration of insulin.

    PubMed

    Andrade, Fernanda; das Neves, José; Gener, Petra; Schwartz, Simó; Ferreira, Domingos; Oliva, Mireia; Sarmento, Bruno

    2015-10-01

    Pulmonary delivery of drugs for both local and systemic action has gained new attention over the last decades. In this work, different amphiphilic polymers (Soluplus®, Pluronic® F68, Pluronic® F108 and Pluronic® F127) were used to produce lyophilized formulations for inhalation of insulin. Development of stimuli-responsive, namely glucose-sensitive, formulations was also attempted with the addition of phenylboronic acid (PBA). Despite influencing the in vitro release of insulin from micelles, PBA did not confer glucose-sensitive properties to formulations. Lyophilized powders with aerodynamic diameter (<6 μm) compatible with good deposition in the lungs did not present significant in vitro toxicity for respiratory cell lines. Additionally, some formulations, in particular Pluronic® F127-based formulations, enhanced the permeation of insulin through pulmonary epithelial models and underwent minimal internalization by macrophages in vitro. Overall, formulations based on polymeric micelles presenting promising characteristics were developed for the delivery of insulin by inhalation. The ability to deliver other systemic drugs via inhalation has received renewed interests in the clinical setting. This is especially true for drugs which usually require injections for delivery, like insulin. In this article, the authors investigated their previously developed amphiphilic polymers for inhalation of insulin in an in vitro model. The results should provide basis for future in vivo studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Synthetic “smart gel” provides glucose-responsive insulin delivery in diabetic mice

    PubMed Central

    Matsumoto, Akira; Tanaka, Miyako; Matsumoto, Hiroko; Ochi, Kozue; Moro-oka, Yuki; Kuwata, Hirohito; Yamada, Hironori; Shirakawa, Ibuki; Miyazawa, Taiki; Ishii, Hitoshi; Kataoka, Kazunori; Ogawa, Yoshihiro; Miyahara, Yuji; Suganami, Takayoshi

    2017-01-01

    Although previous studies have attempted to create “electronics-free” insulin delivery systems using glucose oxidase and sugar-binding lectins as a glucose-sensing mechanism, no successful clinical translation has hitherto been made. These protein-based materials are intolerant of long-term use and storage because of their denaturing and/or cytotoxic properties. We provide a solution by designing a protein-free and totally synthetic material–based approach. Capitalizing on the sugar-responsive properties of boronic acid, we have established a synthetic polymer gel–based insulin delivery device confined within a single catheter, which exhibits an artificial pancreas–like function in vivo. Subcutaneous implantation of the device in healthy and diabetic mice establishes a closed-loop system composed of “continuous glucose sensing” and “skin layer”–regulated insulin release. As a result, glucose metabolism was controlled in response to interstitial glucose fluctuation under both insulin-deficient and insulin-resistant conditions with at least 3-week durability. Our “smart gel” technology could offer a user-friendly and remarkably economic (disposable) alternative to the current state of the art, thereby facilitating availability of effective insulin treatment not only to diabetic patients in developing countries but also to those patients who otherwise may not be strongly motivated, such as the elderly, infants, and patients in need of nursing care. PMID:29202033

  19. Influence of glucosamine on the bioactivity of insulin delivered subcutaneously and in an oral nanodelivery system

    PubMed Central

    Al-Kurdi, Zakieh I; Chowdhry, Babur Z; Leharne, Stephen A; Qinna, Nidal A; Al Omari, Mahmoud MH; Badwan, Adnan A

    2015-01-01

    The aim of the work reported herein was to study the effect of glucosamine HCl (GlcN·HCl) on the bioactivity (BA) of insulin, administered via subcutaneous (SC) and oral routes, in adult male Sprague Dawley rats. The oral insulin delivery system (insulin–chitosan reverse micelle [IC-RM]) was prepared by solubilizing insulin–chitosan (13 kDa) polyelectrolyte complex in a RM system consisting of oleic acid, PEG-8 caprylic/capric glycerides, and polyglycerol-6-dioleate. The BA of insulin in vivo was evaluated by measuring blood glucose level using a blood glucose meter; the results revealed that the extent of hypoglycemic activity of SC insulin was GlcN·HCl dose dependent when they were administered simultaneously. A significant reduction in blood glucose levels (P<0.05) was found for the insulin:GlcN·HCl at mass ratios of 1:10 and 1:20, whereas lower ratios (eg, 1:1 and 1:4) showed no significant reduction. Furthermore, enhancement of the action of SC insulin was achieved by oral administration of GlcN·HCl for 5 consecutive days prior to insulin injection (P<0.05). For oral insulin administration via the IC-RM system, the presence of GlcN·HCl increased the hypoglycemic activity of insulin (P<0.05). The relative BA were 6.7% and 5.4% in the presence and absence of GlcN·HCl (ie, the increase in the relative BA was approximately 23% due to incorporating GlcN·HCl in the IC-RM system), respectively. The aforementioned findings offer an opportunity to incorporate GlcN·HCl in oral insulin delivery systems in order to enhance a reduction in blood glucose levels. PMID:26640369

  20. Solid lipid nanoparticles for pulmonary delivery of insulin.

    PubMed

    Liu, Jie; Gong, Tao; Fu, Hualin; Wang, Changguang; Wang, Xiuli; Chen, Qian; Zhang, Qin; He, Qin; Zhang, Zhirong

    2008-05-22

    Growing attention has been given to the potential of pulmonary route as an alternative for non-invasive systemic delivery of therapeutic agents. In this study, novel nebulizer-compatible solid lipid nanoparticles (SLNs) for pulmonary drug delivery of insulin were developed by reverse micelle-double emulsion method. The influences of the amount of sodium cholate (SC) and soybean phosphatidylcholine (SPC) on the deposition properties of the nanoparticles were investigated. Under optimal conditions, the entrapment delivery (ED), respirable fraction (RF) and nebulization efficiency (NE) of SLNs could reach 96.53, 82.11 and 63.28%, respectively, and Ins-SLNs remained stable during nebulization. Fasting plasma glucose level was reduced to 39.41% and insulin level was increased to approximately 170 microIU/ml 4h after pulmonary administration of 20 IU/kg Ins-SLNs. A pharmacological bioavailability of 24.33% and a relative bioavailability of 22.33% were obtained using subcutaneous injection as a reference. Incorporating fluorescent-labelled insulin into SLNs, we found that the SLNs were effectively and homogeneously distributed in the lung alveoli. These findings suggested that SLNs could be used as a potential carrier for pulmonary delivery of insulin by improving both in vitro and in vivo stability as well as prolonging hypoglycemic effect, which inevitably resulted in enhanced bioavailability.

  1. Conductive polymer nanotube patch for fast and controlled ex vivo transdermal drug delivery.

    PubMed

    Nguyen, Thao M; Lee, Sebin; Lee, Sang Bok

    2014-10-01

    To uptake and release hydrophilic model drugs and insulin in a novel conductive polymer (CP) nanotube transdermal patch. The externally controlled transdermal delivery of model drugs and insulin were tested ex vivo and results were compared with CP films. The unique intrinsic properties of CPs provide electrostatic interaction between the model drugs and polymer backbone. When a pulsed potential was applied, the drug delivery release profile mimics that of injection delivery. With a constant potential applied, the release rate constants of the patch system were up to three-times faster than the control (0 V) and released approximately 80% more drug molecules over 24 h. The CP nanotube transdermal patch represents a new and promising drug method, specifically for hydrophilic molecules, which have been a large obstacle for conventional transdermal drug delivery systems.

  2. In vivo evaluation of a nasal insulin delivery system based on thiolated chitosan.

    PubMed

    Krauland, Alexander H; Leitner, Verena M; Grabovac, Vjera; Bernkop-Schnürch, Andreas

    2006-11-01

    The aim of this study was the preparation and in vivo evaluation of a nasal insulin delivery system based on thiolated chitosan. 2-Iminothiolane was covalently attached to chitosan. The resulting conjugate (chitosan-TBA) exhibited 304.9 +/- 63.5 micromol thiol groups per gram polymer. Microparticles were prepared via a new precipitation-micronization technique. The microparticulate delivery system comprised insulin, reduced glutathione and chitosan-TBA (Chito-TBA/Ins) or unmodified chitosan (Chito/Ins) and control microparticles were composed of insulin and mannitol (Mannitol/Ins). Due to a hydration process the size of Chito-TBA/Ins and Chito/Ins microparticles increased in phosphate buffer pH 6.8 2.6- and 2.2-fold, respectively. Fluorescent-labeled insulin-loaded chitosan-TBA microparticles showed a controlled release over 4 h. Chito-TBA/Ins administered nasally to rats led to an absolute bioavailability of 6.9 +/- 1.5%. The blood glucose level decreased for more than 2 h and the calculated absolute pharmacological efficacy was 4.9 +/- 1.4%. Chito/Ins, in comparison, displayed a bioavailability of 4.2 +/- 1.8% and a pharmacological efficacy of 0.7 +/- 0.6%. Mannitol/Ins showed a bioavailability of 1.6 +/- 0.4% and no reduction of the blood glucose level at all. According to these findings microparticles comprising chitosan-TBA seem to have substantial higher potential for nasal insulin administration than unmodified chitosan. Copyright 2006 Wiley-Liss, Inc. and the American Pharmacists Association

  3. Combining two technologies: multifunctional polymers and self-nanoemulsifying drug delivery system (SNEDDS) for oral insulin administration.

    PubMed

    Sakloetsakun, Duangkamon; Dünnhaupt, Sarah; Barthelmes, Jan; Perera, Glen; Bernkop-Schnürch, Andreas

    2013-10-01

    The aim of the study is to develop a self-nanoemulsifying drug delivery system (SNEDDS) based on thiolated chitosan for oral insulin administration. The preparations were characterized by particle size, entrapment efficiency, stability and drug release. Serum insulin concentrations were determined after oral administration of all formulations. Insulin SNEDDS formulation was served as control. The optimized SNEDDS consists of 65% (w/w) miglyol 840, 25% (w/w) cremophor EL, 10% (w/w) co-solvents (a mixture of DMSO and glycerol). The formulations in the presence or absence of insulin (5mg/mL) were spherical with the size range between 80 and 160 nm. Entrapment efficiency of insulin increased significantly when the thiolated chitosan was employed (95.14±2.96%), in comparison to the insulin SNEDDS (80.38±1.22%). After 30 min, the in vitro release profile of insulin from the nanoemulsions was markedly increased compared to the control. In vivo results showed that insulin/thiolated chitosan SNEDDS displayed a significant increase in serum insulin (p-value=0.02) compared to oral insulin solution. A new strategy to combine SNEDDS and thiolated chitosan described in the study would therefore be a promising and innovative approach to improve oral bioavailability of insulin. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  4. Cyclodextrin-insulin complex encapsulated polymethacrylic acid based nanoparticles for oral insulin delivery.

    PubMed

    Sajeesh, S; Sharma, Chandra P

    2006-11-15

    Present investigation was aimed at developing an oral insulin delivery system based on hydroxypropyl beta cyclodextrin-insulin (HPbetaCD-I) complex encapsulated polymethacrylic acid-chitosan-polyether (polyethylene glycol-polypropylene glycol copolymer) (PMCP) nanoparticles. Nanoparticles were prepared by the free radical polymerization of methacrylic acid in presence of chitosan and polyether in a solvent/surfactant free medium. Dynamic light scattering (DLS) experiment was conducted with particles dispersed in phosphate buffer (pH 7.4) and size distribution curve was observed in the range of 500-800 nm. HPbetaCD was used to prepare non-covalent inclusion complex with insulin and complex was analyzed by Fourier transform infrared (FTIR) and fluorescence spectroscopic studies. HPbetaCD complexed insulin was encapsulated into PMCP nanoparticles by diffusion filling method and their in vitro release profile was evaluated at acidic/alkaline pH. PMCP nanoparticles displayed good insulin encapsulation efficiency and release profile was largely dependent on the pH of the medium. Enzyme linked immunosorbent assay (ELISA) study demonstrated that insulin encapsulated inside the particles was biologically active. Trypsin inhibitory effect of PMCP nanoparticles was evaluated using N-alpha-benzoyl-L-arginine ethyl ester (BAEE) and casein as substrates. Mucoadhesive studies of PMCP nanoparticles were conducted using freshly excised rat intestinal mucosa and the particles were found fairly adhesive. From the preliminary studies, cyclodextrin complexed insulin encapsulated mucoadhesive nanoparticles appear to be a good candidate for oral insulin delivery.

  5. Comparison of the physiological relevance of systemic vs. portal insulin delivery to evaluate whole body glucose flux during an insulin clamp

    PubMed Central

    Farmer, Tiffany D.; Jenkins, Erin C.; O'Brien, Tracy P.; McCoy, Gregory A.; Havlik, Allison E.; Nass, Erik R.; Nicholson, Wendell E.; Printz, Richard L.

    2014-01-01

    To understand the underlying pathology of metabolic diseases, such as diabetes, an accurate determination of whole body glucose flux needs to be made by a method that maintains key physiological features. One such feature is a positive differential in insulin concentration between the portal venous and systemic arterial circulation (P/S-IG). P/S-IG during the determination of the relative contribution of liver and extra-liver tissues/organs to whole body glucose flux during an insulin clamp with either systemic (SID) or portal (PID) insulin delivery was examined with insulin infusion rates of 1, 2, and 5 mU·kg−1·min−1 under either euglycemic or hyperglycemic conditions in 6-h-fasted conscious normal rats. A P/S-IG was initially determined with endogenous insulin secretion to exist with a value of 2.07. During an insulin clamp, while inhibiting endogenous insulin secretion by somatostatin, P/S-IG remained at 2.2 with PID, whereas, P/S-IG disappeared completely with SID, which exhibited higher arterial and lower portal insulin levels compared with PID. Consequently, glucose disappearance rates and muscle glycogen synthetic rates were higher, but suppression of endogenous glucose production and liver glycogen synthetic rates were lower with SID compared with PID. When the insulin clamp was performed with SID at 2 and 5 mU·kg−1·min−1 without managing endogenous insulin secretion under euglycemic but not hyperglycemic conditions, endogenous insulin secretion was completely suppressed with SID, and the P/S-IG disappeared. Thus, compared with PID, an insulin clamp with SID underestimates the contribution of liver in response to insulin to whole body glucose flux. PMID:25516552

  6. Glucose-responsive insulin delivery for type 1 diabetes: The artificial pancreas story.

    PubMed

    Bally, Lia; Thabit, Hood; Hovorka, Roman

    2018-06-15

    Insulin replacement therapy is integral to the management of type 1 diabetes, which is characterised by absolute insulin deficiency. Optimal glycaemic control, as assessed by glycated haemoglobin, and avoidance of hyper- and hypoglycaemic excursions have been shown to prevent diabetes-related complications. Insulin pump use has increased considerably over the past decade with beneficial effects on glycaemic control, quality of life and treatment satisfaction. The advent and progress of ambulatory glucose sensor technology has enabled continuous glucose monitoring based on real-time glucose levels to be integrated with insulin therapy. Low glucose and predictive low glucose suspend systems are currently used in clinical practice to mitigate against hypoglycaemia, and provide the first step towards feedback glucose control. The more advanced technology approach, an artificial pancreas or a closed-loop system, gradually increases and decreases insulin delivery in a glucose-responsive fashion to mitigate against hyper- and hypoglycaemia. Randomised outpatient clinical trials over the past 5 years have demonstrated the feasibility, safety and efficacy of the approach, and the recent FDA approval of the first single hormone closed-loop system establishes a new standard of care for people with type 1 diabetes. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Insulin Delivery System

    NASA Technical Reports Server (NTRS)

    1988-01-01

    When Programmable Implantable Medication System (PIMS) is implanted in human body, it delivers precise programmed amounts of insulin over long periods of time. Mini-Med Technologies has been refining the Technologies since initial development at APL. The size of a hockey puck, and encased in titanium shell, PIMS holds about 2 1/2 teaspoons of insulin at a programmed basal rate. If a change in measured blood sugar level dictates a different dose, the patient can vary the amount of insulin delivered by holding a small radio transceiver over the implanted system and dialing in a specific program held in the PIMS computer memory. Insulin refills are accomplished approximately 4 times a year by hypodermic needle.

  8. Toward Automation of Insulin Delivery - Management Solutions for Type 1 Diabetes.

    PubMed

    Nimri, Revital; Phillip, Moshe

    2016-01-01

    In the past decade, the field of type 1 diabetes was characterized by the efforts to integrate technology into the daily management of diabetes. Automated insulin delivery systems have emerged followed by the improvements in technology of pumps and sensors and automated close-loop systems that were developed around the world for overnight as well as for day and night use. Initially, these closed-loop systems were tested clinically in research centers, then at diabetes camps or hotels, and recently at patients' homes. The systems were tested in a wide range of populations of patients with type 1 diabetes: children, adolescents, adults, newly diagnosed, well and suboptimally controlled patients, the critically ill and pregnant women. The extensive clinical evaluation found these close-loop systems to be safe and efficient in controlling blood glucose levels. Now is the time to take these systems from research to industry and to get a regulatory approval of convenient devices for the use at home. Automated insulin delivery systems have the potential to change the way diabetes is treated and managed for the benefit of patients. This chapter summarizes the recent advances in this field. © 2016 S. Karger AG, Basel.

  9. V-Go Insulin Delivery System Versus Multiple Daily Insulin Injections for Patients With Uncontrolled Type 2 Diabetes Mellitus.

    PubMed

    Winter, Abigail; Lintner, Michaela; Knezevich, Emily

    2015-04-21

    Type 2 diabetes mellitus affects over 29.1 million Americans, diagnosed and undiagnosed. Achieving and maintaining glycemic control for these patients is of extreme importance when working to prevent complications and improve quality of life for patients. The V-Go is a newly developed insulin delivery system. The push of a button inserts a needle into the patient once daily and remains attached for 24 hours. The V-Go is designed to release a set basal rate throughout the day, while allowing patients to provide up to 36 units of on-demand bolus insulin with the manual click of 2 buttons. It is a spring-loaded device filled daily with rapid-acting insulin that runs without the use of batteries or computer software. The main objective of this prospective active comparator study was to observe the A1C lowering effects of multiple daily insulin injections (MDII) versus the use of the V-Go insulin delivery system for patients with uncontrolled type 2 diabetes mellitus over a 3-month period. In addition, the effect on insulin requirement for these patients was assessed with secondary comparisons of weight, blood pressure, prevalence of hypoglycemic events, and quality of life before and after 3 months of intensified insulin therapy with regular monitoring by a clinical pharmacist at an internal medicine clinic. The average A1C lowering experienced by the 3 patients in the V-Go group was 1.5%, while the average A1C change in the 3 patients in the MDII group was an increase of 0.2%. All patients in the V-Go group experienced a decrease in insulin total daily dose (TDD), with an average decrease of 26.3 units. All patients in the MDII group experienced an increase in insulin TDD with an average of 15 units daily to achieve therapeutic goals individualized for each patient. All patients who underwent intensification of insulin therapy experienced an increase in subjective quality of life (QOL) as determined using the Diabetes-39 (D-39) questionnaire, though QOL results lacked statistical significance. © 2015 Diabetes Technology Society.

  10. Considerations in insulin delivery device selection.

    PubMed

    Valentine, Virginia; Kruger, Davida F

    2010-06-01

    Recent guidelines from the American Diabetes Association and the European Association for the Study of Diabetes promote the use of insulin sooner rather than later in patients with type 2 diabetes to achieve goal range glucose control (< 7%) but remain silent on a recommendation for delivery system. Even though there is widespread consensus among experts and payers that people with type 2 diabetes should use insulin earlier to achieve tight control, it still remains an elusive goal. Benefits of pen-type delivery devices include accurate dosing, faster and easier setting of dose and injection times, and increased patient acceptance and adherence. Before healthcare professionals can recommend a delivery device, it is critical they understand not only the medication in the device but also the various features and benefits to the different devices available and how those impact the patient. We will present considerations to assist in making appropriate device selection, to optimize patient success.

  11. New developments in the treatment of type 1 diabetes mellitus.

    PubMed

    Haak, T

    1999-01-01

    Treatment of type 1 diabetes mellitus has made tremendous advances within the last decades. With concern to insulin delivery there are two promising new approaches. One is the intrapulmonary insulin delivery which has become feasible by the development of new inhalation devices which provide a sufficient degree of intrapulmonary drug retention. Also oral insulin delivery seems feasible when surface active substances are used to cross the mucosal membrane in the gut. Clinical research has also focussed on coatings for the insulin molecules to solve the problem raised by the proteolytic activity of the digestive system. A very new agent produced by a fungus called Pseudomassaria has been demonstrated to reverse the clinical signs of diabetes mellitus in mice. The compound diffuses through the cell membrane, binds to the inner part of the insulin receptor and activates the insulin typical biological effects. Nowadays a variety of insulin analogs are designed and tested for their clinical use. By shifting the isoelectric point towards to a slightly acidic pH, HOE 901 precipitates at physiologic pH resulting in a constant and peakless insulin delivery. NN 304 is a 14-carbon aliphatic fatty acid acylated analog that binds to serum albumin resulting in a flatter time-action profile than NPH insulin. Also rapid acting insulin analogs are or will be launched in the near future aiming to ensure an improved postprandial glucose regulation. Glucagon-like peptide-1 (GLP-1) improves metabolic control by a variety of effects, e.g. the enhancement of insulin secretion and inhibition of glucagon secretion. Moreover, GLP-1 reduces food and water intake controlled by the brain, and inhibits gastric emptying. A disadvantage of GLP-1 is its very short half-life. Novel derivatives with the beneficial effects of GLP-1 but a better resistance against degradation have been designed. In addition substances have been developed inhibiting GLP-1 degradation or augmenting GLP-1 release from its abundant endogenous pool. Finally, there is a variety of interesting approaches aiming to improve or ease blood glucose self-monitoring. One is the development of subcutaneous catheters for continuous blood glucose control. In another system reverse iontophoresis is used for sampling interstitial fluid which reflects capillary blood glucose levels. Instead of using an electric current, a brandnew system creates micropores in the skin by a laser ablation system. Through these micropores a specific device performs a mild suction to obtain intersitial fluid. Further systems which measure blood glucose by near infrared spectroscopy are still investigated in order to improve their technical function and to reduce their weight. This article intends to give an overview over the new developments in the treatment and management of type-1-diabetes mellitus.

  12. Effective oral delivery of insulin in animal models using vitamin B12-coated dextran nanoparticles.

    PubMed

    Chalasani, Kishore B; Russell-Jones, Gregory J; Jain, Akhlesh K; Diwan, Prakash V; Jain, Sanjay K

    2007-09-26

    The potential utility of vitamin B12 carrier system for the oral delivery of conjugated peptides/proteins and enhancement of nanoparticles (NPs) transport has been demonstrated. The present study aims to optimize the effectiveness of VB12-NPs conjugates using different levels of cross-linking, linked with different VB(12)-coatings and evaluates in animal models to investigate an efficient insulin carrier. Amino alkyl VB12 derivatives suitable for oral delivery were synthesized at 5'hydoxy ribose and e-propionamide sites via carbamate and ester/amide linkages, and were coupled to succinic acid modified dextran NPs of varied cross-linking. VB12 binding was confirmed by XPS analysis, and was quantified by HPLC (4.0 to 5.7% w/w of NPs). These polydisperse NPs conjugates showed higher size, high insulin entrapment and faster insulin release with low levels of cross-linking. These VB12-NPs conjugates (150-300 nm) showed profound (70-75% blood glucose reductions) and prolonged (54 h) anti-diabetic effects with biphasic behaviour in STZ diabetic rats. NPs with the low levels of cross-linking were found to be superior carriers, and were more effective with VB12 derivatives of carbamate linkage. The pharmacological availability relative to SC insulin was found to be 29.4%, which was superior compared to NPs conjugate of ester linked VB12 (1.5 fold) and relatively higher cross-linked particles (1.1 fold). Further, the NPs carrier demonstrated a similar oral insulin efficacy in congenital diabetic mice (60% reduction at 20 h). Significant quantities of plasma insulin were found in both animal models (231 and 197 muIU/ml). At two investigated doses, the carrier system shows dose response. Pre-dosing with a large excess of free VB12 minimized the observed activity, indicating predominance of VB12 mediated uptake. It is concluded that VB12-dextran NPs conjugate is a viable carrier for peroral insulin delivery to treat diabetics.

  13. Technology to Reduce Hypoglycemia

    PubMed Central

    Yeoh, Ester; Choudhary, Pratik

    2015-01-01

    Hypoglycemia is a major barrier toward achieving glycemic targets and is associated with significant morbidity (both psychological and physical) and mortality. This article reviews technological strategies, from simple to more advanced technologies, which may help prevent or mitigate exposure to hypoglycemia. More efficient insulin delivery systems, bolus advisor calculators, data downloads providing information on glucose trends, continuous glucose monitoring with alarms warning of hypoglycemia, predictive algorithms, and finally closed loop insulin delivery systems are reviewed. The building blocks to correct use and interpretation of this range of available technology require patient education and appropriate patient selection. PMID:25883167

  14. Drug transport mechanism of oral antidiabetic nanomedicines.

    PubMed

    Gundogdu, Evren; Yurdasiper, Aysu

    2014-01-01

    Over the last few decades, extensive efforts have been made worldwide to develop nanomedicine delivery systems, especially via oral route for antidiabetic drugs. Absorption of insulin is hindered by epithelial cells of gastrointestinal tract, acidic gastric pH and digestive enzymes. Recent reports have identified and explained the beneficial role of several structural molecules like mucoadhesive polymers (polyacrylic acid, sodium alginate, chitosan) and other copolymers for the efficient transport and release of insulin to its receptors. Insulin nanomedicines based on alginate-dextran sulfate core with a chitosan-polyethylene glycol-albumin shell reduced glycaemia in a dose dependent manner. Orally available exendin-4 formulations exerted their effects in a time dependent manner. Insulin nanoparticles formed by using alginate and dextran sulfate nucleating around calcium and binding to poloxamer, stabilized by chitosan, and subsequently coated with albumin showed a threefold increase of the hypoglycemic effect in comparison to free insulin in animal models. Solid lipid nanoparticles showed an enhancement of the bioavailability of repaglinide (RG) within optimized solid lipid nanoparticle formulations when compared with RG alone. Nanoparticles represent multiparticulate delivery systems designed to obtain prolonged or controlled drug delivery and to improve bioavailability as well as stability. Nanoparticles can also offer advantages like limiting fluctuations within therapeutic range, reducing side effects, protecting drugs from degradation, decreasing dosing frequency, and improving patient compliance and convenience.

  15. Low Molecular Weight Chitosan–Insulin Polyelectrolyte Complex: Characterization and Stability Studies

    PubMed Central

    Al-Kurdi, Zakieh I.; Chowdhry, Babur Z.; Leharne, Stephen A.; Al Omari, Mahmoud M. H.; Badwan, Adnan A.

    2015-01-01

    The aim of the work reported herein was to investigate the effect of various low molecular weight chitosans (LMWCs) on the stability of insulin using USP HPLC methods. Insulin was found to be stable in a polyelectrolyte complex (PEC) consisting of insulin and LMWC in the presence of a Tris-buffer at pH 6.5. In the presence of LMWC, the stability of insulin increased with decreasing molecular weight of LMWC; 13 kDa LMWC was the most efficient molecular weight for enhancing the physical and chemical stability of insulin. Solubilization of insulin-LMWC polyelectrolyte complex (I-LMWC PEC) in a reverse micelle (RM) system, administered to diabetic rats, results in an oral delivery system for insulin with acceptable bioactivity. PMID:25830681

  16. In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes.

    PubMed

    Kovatchev, Boris P; Breton, Marc; Man, Chiara Dalla; Cobelli, Claudio

    2009-01-01

    Arguably, a minimally invasive system using subcutaneous (s.c.) continuous glucose monitoring (CGM) and s.c. insulin delivery via insulin pump would be a most feasible step to closed-loop control in type 1 diabetes mellitus (T1DM). Consequently, diabetes technology is focusing on developing an artificial pancreas using control algorithms to link CGM with s.c. insulin delivery. The future development of the artificial pancreas will be greatly accelerated by employing mathematical modeling and computer simulation. Realistic computer simulation is capable of providing invaluable information about the safety and the limitations of closed-loop control algorithms, guiding clinical studies, and out-ruling ineffective control scenarios in a cost-effective manner. Thus computer simulation testing of closed-loop control algorithms is regarded as a prerequisite to clinical trials of the artificial pancreas. In this paper, we present a system for in silico testing of control algorithms that has three principal components: (1) a large cohort of n=300 simulated "subjects" (n=100 adults, 100 adolescents, and 100 children) based on real individuals' data and spanning the observed variability of key metabolic parameters in the general population of people with T1DM; (2) a simulator of CGM sensor errors representative of Freestyle Navigator™, Guardian RT, or Dexcom™ STS™, 7-day sensor; and (3) a simulator of discrete s.c. insulin delivery via OmniPod Insulin Management System or Deltec Cozmo(®) insulin pump. The system has been shown to represent adequate glucose fluctuations in T1DM observed during meal challenges, and has been accepted by the Food and Drug Administration as a substitute to animal trials in the preclinical testing of closed-loop control strategies. © Diabetes Technology Society

  17. The Clinical and Economic Impact of the V-Go® Disposable Insulin Delivery Device for Insulin Delivery in Patients with Poorly Controlled Diabetes at High Risk.

    PubMed

    Lajara, Rosemarie; Nikkel, Carla; Abbott, Scott

    2016-06-01

    Diabetes is a chronic condition and when poorly controlled can lead to complications and death. Patients with glycated hemoglobin (A1C) measures >9 % are at significant risk for diabetes-related complications impacting the patient's quality of life and imposing higher costs on the healthcare system. A1C reductions of 1 % or greater in this population have demonstrated substantial health and economic benefits. Reducing the percent of patients at risk is an essential component of quality-care measures established for patients with diabetes. To evaluate if switching patients prescribed subcutaneous insulin injections to V-Go for insulin delivery would impact clinical and economic parameters in patients with poorly controlled diabetes (A1C > 9 %). The study was a retrospective analysis using data extracted from the electronic medical records database of a multicenter diabetes system. Outcome measures included mean change in A1C from baseline, the percent of patients achieving a reduction in A1C ≥1 % while on V-Go therapy, and the impact to quality measures. In addition, economic analyses were conducted to assess the pharmacy budget impact and projected implication to total healthcare cost. Ninety-seven patients were evaluated after a mean duration of 13.6 ± 6.9 weeks of insulin delivery with V-Go. Switching to V-Go resulted in an overall mean change (95 % CI) in A1C of -2.0 % (-1.7 to -2.3; p  < 0.001) from a baseline of 10.5 %. Seventy-three percent of patients achieved an A1C reduction ≥1 %. Cost analysis supported a direct pharmacy savings of $119.30 (18.80-219.60, p  = 0.020) per patient per month compared with baseline. Switching to V-Go for insulin delivery resulted in significant glycemic improvement and proved cost effective. This real-world assessment could be applied more broadly at the health system and plan level.

  18. Thiolated Eudragit nanoparticles for oral insulin delivery: preparation, characterization and in vivo evaluation.

    PubMed

    Zhang, Yan; Wu, Xiaorong; Meng, Lingkuo; Zhang, Yu; Ai, Ruiting; Qi, Na; He, Haibing; Xu, Hui; Tang, Xing

    2012-10-15

    In the present study thiolated Eudragit L100 (Eul) based polymeric nanoparticles (NPs) were employed to develop an oral insulin delivery system. Sulfydryl modification was achieved by grafting cysteine to the carboxylic acid group of Eudragit L100, which displayed maximum conjugate level of 390.3±13.4 μmol thiol groups per gram. Eudragit L100-cysteine (Eul-cys) and Eul nanoparticles were prepared by the precipitation method, in which reversible swelling of pH-sensitive material was used for insulin loading and release. Nanoparticles were characterized in terms of their particle size, morphology, loading efficiency (LE%) and in vitro insulin release behavior. The NPs had an average size of 324.2±39.0 nm and 308.8±35.7 nm, maximal LE% of 92.2±1.7% and 96.4±0.5% for Eul-cys and Eul, respectively. The release profile of NPs in vitro showed pH-dependent behavior. Circular dichroism (CD) spectroscopy analysis proved that the secondary structure of the insulin released from NPs was unchanged compared with native insulin. The mucoadhesion study in vitro showed that Eul-cys NPs produced a 3-fold and 2.8-fold increase in rat jejunum and ileum compared with unmodified polymer NPs, respectively, which was due to the immobilization of thiol groups on Eudragit L100. Oral administration of insulin-loaded Eul-cys NPs produced a higher and prolonged hypoglycemic action, and the corresponding relative bioavailability of insulin was found to be 7.33±0.33%, an increase of 2.8-fold compared with Eul NPs (2.65±0.63%). This delivery system is a promising novel tool to improve the absorption of protein and peptide drugs in the intestinal tract. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Preparation and characterization of glycoprotein-resistant starch complex as a coating material for oral bioadhesive microparticles for colon-targeted polypeptide delivery.

    PubMed

    Situ, Wenbei; Li, Xiaoxi; Liu, Jia; Chen, Ling

    2015-04-29

    For effective oral delivery of polypeptide or protein and enhancement their oral bioavailability, a new resistant starch-glycoprotein complex bioadhesive carrier and an oral colon-targeted bioadhesive delivery microparticle system were developed. A glycoprotein, concanavalin A (Con A), was successfully conjugated to the molecules of resistant starch acetate (RSA), leading to the formation of resistant starch-glycoprotein complex. This Con A-conjugated RSA film as a coating material showed an excellent controlled-release property. In streptozotocin (STZ)-induced type II diabetic rats, the insulin-loaded microparticles coated with this Con A-conjugated RSA film exhibited good hypoglycemic response for keeping the plasma glucose level within the normal range for totally 44-52 h after oral administration with different insulin dosages. Oral glucose tolerance tests indicated that successive oral administration of these colon-targeted bioadhesive microparticles with insulin at a level of 50 IU/kg could achieve a hypoglycemic effect similar to that by injection of insulin at 35 IU/kg. Therefore, the potential of this new Con A-conjugated RSA film-coated microparticle system has been demonstrated to be capable of improving the oral bioavailability of bioactive proteins and peptides.

  20. An Amperometric Glucose Sensor Integrated into an Insulin Delivery Cannula: In Vitro and In Vivo Evaluation

    PubMed Central

    Heinrich, Gabriel; Breen, Matthew; Benware, Sheila; Vollum, Nicole; Morris, Kristin; Knutsen, Chad; Kowalski, Joseph D.; Campbell, Scott; Biehler, Jerry; Vreeke, Mark S.; Vanderwerf, Scott M.; Castle, Jessica R.; Cargill, Robert S.

    2017-01-01

    Abstract Background: Labeling prohibits delivery of insulin at the site of subcutaneous continuous glucose monitoring (CGM). Integration of the sensing and insulin delivery functions into a single device would likely increase the usage of CGM in persons with type 1 diabetes. Methods: To understand the nature of such interference, we measured glucose at the site of bolus insulin delivery in swine using a flexible electrode strip that was laminated to the outer wall of an insulin delivery cannula. In terms of sensing design, we compared H2O2-measuring sensors biased at 600 mV with redox mediator-type sensors biased at 175 mV. Results: In H2O2-measuring sensors, but not in sensors with redox-mediated chemistry, a spurious rise in current was seen after insulin lis-pro boluses. This prolonged artifact was accompanied by electrode poisoning. In redox-mediated sensors, the patterns of sensor signals acquired during delivery of saline and without any liquid delivery were similar to those acquired during insulin delivery. Conclusion: Considering in vitro and in vivo findings together, it became clear that the mechanism of interference is the oxidation, at high bias potentials, of phenolic preservatives present in insulin formulations. This effect can be avoided by the use of redox mediator chemistry using a low bias potential. PMID:28221814

  1. A Review of Artificial Pancreas Technologies with an Emphasis on Bi-hormonal Therapy

    PubMed Central

    Bakhtiani, Parkash A.; Zhao, Lauren M.; Youssef, Joseph El; Castle, Jessica R.; Ward, W. Kenneth

    2013-01-01

    Since the discovery of insulin, great progress has been made to improve the accuracy and safety of automated insulin delivery systems to help patients with type 1 diabetes achieve their treatment goals without causing hypoglycemia. In recent years, bioengineering technology has greatly advanced diabetes management, with the development of blood glucose meters, continuous glucose monitors, insulin pumps, and control systems for automatic delivery of one or more hormones. New insulin analogues have improved subcutaneous absorption characteristics, but do not completely eliminate the risk of hypoglycemia. Insulin effect is counteracted by glucagon in non-diabetic individuals, while glucagon secretion in those with type 1 diabetes is impaired. The use of glucagon in the artificial pancreas is therefore a logical and feasible option for preventing and treating hypoglycemia. However, commercially available glucagon is not stable in aqueous solution for long periods, forming potentially cytotoxic fibrils that aggregate quickly. Therefore, a more stable formulation of glucagon is needed for long-term use and storage in a bi-hormonal pump. Additionally, a model of glucagon action in type 1 diabetes is lacking, further limiting the inclusion of glucagon into systems employing model-assisted control. As a result, although several investigators have been working to help develop bi-hormonal systems for patients with type 1 diabetes, most continue to utilize single hormone systems employing only insulin. This article seeks to focus on the attributes of glucagon and its use in bi-hormonal systems. PMID:23602044

  2. Technology to Reduce Hypoglycemia.

    PubMed

    Yeoh, Ester; Choudhary, Pratik

    2015-07-01

    Hypoglycemia is a major barrier toward achieving glycemic targets and is associated with significant morbidity (both psychological and physical) and mortality. This article reviews technological strategies, from simple to more advanced technologies, which may help prevent or mitigate exposure to hypoglycemia. More efficient insulin delivery systems, bolus advisor calculators, data downloads providing information on glucose trends, continuous glucose monitoring with alarms warning of hypoglycemia, predictive algorithms, and finally closed loop insulin delivery systems are reviewed. The building blocks to correct use and interpretation of this range of available technology require patient education and appropriate patient selection. © 2015 Diabetes Technology Society.

  3. Expectations about insulin therapy, perceived insulin-delivery system social acceptability, and insulin treatment satisfaction contribute to decreases in insulin therapy self-efficacy in patients with type 2 diabetes after 36 weeks insulin therapy.

    PubMed

    Hayes, Risa P; Curtis, Bradley; Ilag, Liza; Nelson, David R; Wong, Mayme; Funnell, Martha

    2013-09-01

    Self-efficacy plays a critical role in diabetes self-care. Herein we explore factors contributing to decreased insulin therapy self-efficacy in insulin-naïve patients with type 2 diabetes mellitus (T2DM) initiating and managing insulin therapy over 36 weeks. The study was conducted within an international, randomized clinical trial comparing two insulin therapies administered by insulin pen in patients with T2DM inadequately controlled with oral antihyperglycemic medications. Patients completed the Self-Efficacy about Insulin Therapy Questionnaire (SEITQ) at baseline and endpoint. Patients also completed patient-reported measures assessing expectations about insulin therapy at baseline and perceptions about insulin therapy and insulin-delivery system (IDS) satisfaction at endpoint. Baseline and endpoint SEITQ scores were compared. Using prespecified criteria, patients were classified as having "decreased" or "no change/improved" insulin self-efficacy. Demographic, clinical, and patient-reported variables were entered into a logistic regression model with decreased insulin self-efficacy (yes or no) as the dependent variable. Baseline and endpoint SEITQ data were available for 450 insulin-naïve T2DM patients (mean age 59 years; 53% female; 57% Caucasian; mean baseline HbA1c 9.4%; 80.0 mmol/mol). Insulin therapy self-efficacy improved from baseline to endpoint (74.0 vs 77.5; P<0.001). Logistic regression analysis indicated that lower IDS satisfaction (P<0.0001), lower IDS social acceptability (P=0.004), and more positive expectations of insulin therapy (P<0.0001) were associated with decreased insulin self-efficacy. A candid discussion between clinicians and their insulin-naïve T2DM patients about the benefits and challenges of insulin therapy may prevent unrealistic expectations that could potentially undermine insulin self-efficacy. © 2013 Wiley Publishing Asia Pty Ltd and Ruijin Hospital, Shanghai Jiaotong University School of Medicine.

  4. Intranasal Insulin Prevents Cognitive Decline, Cerebral Atrophy and White Matter Changes in Murine Type I Diabetic Encephalopathy

    ERIC Educational Resources Information Center

    Francis, George J.; Martinez, Jose A.; Liu, Wei Q.; Xu, Kevin; Ayer, Amit; Fine, Jared; Tuor, Ursula I.; Glazner, Gordon; Hanson, Leah R.; Frey, William H., II; Toth, Cory

    2008-01-01

    Insulin deficiency in type I diabetes may lead to cognitive impairment, cerebral atrophy and white matter abnormalities. We studied the impact of a novel delivery system using intranasal insulin (I-I) in a mouse model of type I diabetes (streptozotocin-induced) for direct targeting of pathological and cognitive deficits while avoiding potential…

  5. Day-and-Night Hybrid Closed-Loop Insulin Delivery in Adolescents With Type 1 Diabetes: A Free-Living, Randomized Clinical Trial.

    PubMed

    Tauschmann, Martin; Allen, Janet M; Wilinska, Malgorzata E; Thabit, Hood; Stewart, Zoë; Cheng, Peiyao; Kollman, Craig; Acerini, Carlo L; Dunger, David B; Hovorka, Roman

    2016-07-01

    To evaluate feasibility, safety, and efficacy of day-and-night hybrid closed-loop insulin delivery in adolescents with type 1 diabetes under free-living conditions without remote monitoring or supervision. In an open-label, randomized, free-living, crossover study design, 12 adolescents receiving insulin pump therapy (mean [±SD] age 15.4 ± 2.6 years; HbA1c 8.3 ± 0.9%; duration of diabetes 8.2 ± 3.4 years) underwent two 7-day periods of sensor-augmented insulin pump therapy or hybrid closed-loop insulin delivery without supervision or remote monitoring. During the closed-loop insulin delivery, a model predictive algorithm automatically directed insulin delivery between meals and overnight; prandial boluses were administered by participants using a bolus calculator. The proportion of time when the sensor glucose level was in the target range (3.9-10 mmol/L) was increased during closed-loop insulin delivery compared with sensor-augmented pump therapy (72 vs. 53%, P < 0.001; primary end point), the mean glucose concentration was lowered (8.7 vs. 10.1 mmol/L, P = 0.028), and the time spent above the target level was reduced (P = 0.005) without changing the total daily insulin amount (P = 0.55). The time spent in the hypoglycemic range was low and comparable between interventions. Unsupervised day-and-night hybrid closed-loop insulin delivery at home is feasible and safe in young people with type 1 diabetes. Compared with sensor-augmented insulin pump therapy, closed-loop insulin delivery may improve glucose control without increasing the risk of hypoglycemia in adolescents with suboptimally controlled type 1 diabetes. © 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  6. An Overview of Insulin Pumps and Glucose Sensors for the Generalist

    PubMed Central

    McAdams, Brooke H.; Rizvi, Ali A.

    2016-01-01

    Continuous subcutaneous insulin, or the insulin pump, has gained popularity and sophistication as a near-physiologic programmable method of insulin delivery that is flexible and lifestyle-friendly. The introduction of continuous monitoring with glucose sensors provides unprecedented access to, and prediction of, a patient’s blood glucose levels. Efforts are underway to integrate the two technologies, from “sensor-augmented” and “sensor-driven” pumps to a fully-automated and independent sensing-and-delivery system. Implantable pumps and an early-phase “bionic pancreas” are also in active development. Fine-tuned “pancreas replacement” promises to be one of the many avenues that offers hope for individuals suffering from diabetes. Although endocrinologists and diabetes specialists will continue to maintain expertise in this field, it behooves the primary care physician to have a working knowledge of insulin pumps and sensors to ensure optimal clinical care and decision-making for their patients. PMID:26742082

  7. Drug Transport Mechanism of Oral Antidiabetic Nanomedicines

    PubMed Central

    Gundogdu, Evren; Yurdasiper, Aysu

    2014-01-01

    Context: Over the last few decades, extensive efforts have been made worldwide to develop nanomedicine delivery systems, especially via oral route for antidiabetic drugs. Absorption of insulin is hindered by epithelial cells of gastrointestinal tract, acidic gastric pH and digestive enzymes. Evidence Acquisition: Recent reports have identified and explained the beneficial role of several structural molecules like mucoadhesive polymers (polyacrylic acid, sodium alginate, chitosan) and other copolymers for the efficient transport and release of insulin to its receptors. Results: Insulin nanomedicines based on alginate-dextran sulfate core with a chitosan-polyethylene glycol-albumin shell reduced glycaemia in a dose dependent manner. Orally available exendin-4 formulations exerted their effects in a time dependent manner. Insulin nanoparticles formed by using alginate and dextran sulfate nucleating around calcium and binding to poloxamer, stabilized by chitosan, and subsequently coated with albumin showed a threefold increase of the hypoglycemic effect in comparison to free insulin in animal models. Solid lipid nanoparticles showed an enhancement of the bioavailability of repaglinide (RG) within optimized solid lipid nanoparticle formulations when compared with RG alone. Conclusions: Nanoparticles represent multiparticulate delivery systems designed to obtain prolonged or controlled drug delivery and to improve bioavailability as well as stability. Nanoparticles can also offer advantages like limiting fluctuations within therapeutic range, reducing side effects, protecting drugs from degradation, decreasing dosing frequency, and improving patient compliance and convenience PMID:24696697

  8. Development and characterisation of chitosan films impregnated with insulin loaded PEG-b-PLA nanoparticles (NPs): a potential approach for buccal delivery of macromolecules.

    PubMed

    Giovino, Concetta; Ayensu, Isaac; Tetteh, John; Boateng, Joshua S

    2012-05-30

    Mucoadhesive chitosan based films, incorporated with insulin loaded nanoparticles (NPs) made of poly(ethylene glycol)methyl ether-block-polylactide (PEG-b-PLA) have been developed and characterised. Blank-NPs were prepared by double emulsion solvent evaporation technique with varying concentrations of the copolymer (5 and 10%, w/v). The optimised formulation was loaded with insulin (model protein) at initial loadings of 2, 5 and 10% with respect to copolymer weight. The developed NPs were analysed for size, size distribution, surface charge, morphology, encapsulation efficiency and drug release. NPs showing negative (ζ)-potential (<-6 mV) with average diameter> 300 nm and a polydispersity index (P.I.) of ≈ 0.2, irrespective of formulation process, were achieved. Insulin encapsulation efficiencies of 70% and 30% for NPs-Insulin-2 and NPs-Insulin-5 were obtained, respectively. The in vitro release behaviour of both formulations showed a classic biphasic sustained release of protein over 5 weeks which was influenced by pH of the release medium. Optimised chitosan films embedded with 3mg of insulin loaded NPs were produced by solvent casting with homogeneous distribution of NPs in the mucoadhesive matrix, which displayed excellent physico-mechanical properties. The drug delivery system has been designed as a novel platform for potential buccal delivery of macromolecules. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Thiol functionalized polymethacrylic acid-based hydrogel microparticles for oral insulin delivery.

    PubMed

    Sajeesh, S; Vauthier, C; Gueutin, C; Ponchel, G; Sharma, Chandra P

    2010-08-01

    In the present study thiol functionalized polymethacrylic acid-polyethylene glycol-chitosan (PCP)-based hydrogel microparticles were utilized to develop an oral insulin delivery system. Thiol modification was achieved by grafting cysteine to the activated surface carboxyl groups of PCP hydrogels (Cys-PCP). Swelling and insulin loading/release experiments were conducted on these particles. The ability of these particles to inhibit protease enzymes was evaluated under in vitro experimental conditions. Insulin transport experiments were performed on Caco-2 cell monolayers and excised intestinal tissue with an Ussing chamber set-up. Finally, the efficacy of insulin-loaded particles in reducing the blood glucose level in streptozotocin-induced diabetic rats was investigated. Thiolated hydrogel microparticles showed less swelling and had a lower insulin encapsulation efficiency as compared with unmodified PCP particles. PCP and Cys-PCP microparticles were able to inhibit protease enzymes under in vitro conditions. Thiolation was an effective strategy to improve insulin absorption across Caco-2 cell monolayers, however, the effect was reduced in the experiments using excised rat intestinal tissue. Nevertheless, functionalized microparticles were more effective in eliciting a pharmacological response in diabetic animal, as compared with unmodified PCP microparticles. From these studies thiolation of hydrogel microparticles seems to be a promising approach to improve oral delivery of proteins/peptides. Copyright 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. A rapid-acting, long-acting insulin formulation based on a phospholipid complex loaded PHBHHx nanoparticles.

    PubMed

    Peng, Qiang; Zhang, Zhi-Rong; Gong, Tao; Chen, Guo-Qiang; Sun, Xun

    2012-02-01

    The application of poly(hydroxybutyrate-co-hydroxyhexanoate) (PHBHHx) for sustained and controlled delivery of hydrophilic insulin was made possible by preparing insulin phospholipid complex loaded biodegradable PHBHHx nanoparticles (INS-PLC-NPs). The INS-PLC-NPs produced by a solvent evaporation method showed a spherical shape with a mean particle size, zeta potential and entrapment efficiency of 186.2 nm, -38.4 mv and 89.73%, respectively. In vitro studies demonstrated that only 20% of insulin was released within 31 days with a burst release of 5.42% in the first 8 h. The hypoglycaemic effect in STZ induced diabetic rats lasted for more than 3 days after the subcutaneous injection of INS-PLC-NPs, which significantly prolonged the therapeutic effect compared with the administration of insulin solution. The pharmacological bioavailability (PA) of INS-PLC-NPs relative to insulin solution was over 350%, indicating that the bioavailability of insulin was significantly enhanced by INS-PLC-NPs. Therefore, the INS-PLC-NPs system is promising to serve as a long lasting insulin release formulation, by which the patient compliance can be enhanced significantly. This study also showed that phospholipid complex loaded biodegradable nanoparticles (PLC-NPs) have a great potential to be used as a sustained delivery system for hydrophilic proteins to be encapsulated in hydrophobic polymers. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Regulation of Protein Secretion Through Controlled Aggregation in the Endoplasmic Reticulum

    NASA Astrophysics Data System (ADS)

    Rivera, Victor M.; Wang, Xiurong; Wardwell, Scott; Courage, Nancy L.; Volchuk, Allen; Keenan, Terence; Holt, Dennis A.; Gilman, Michael; Orci, Lelio; Cerasoli, Frank; Rothman, James E.; Clackson, Tim

    2000-02-01

    A system for direct pharmacologic control of protein secretion was developed to allow rapid and pulsatile delivery of therapeutic proteins. A protein was engineered so that it accumulated as aggregates in the endoplasmic reticulum. Secretion was then stimulated by a synthetic small-molecule drug that induces protein disaggregation. Rapid and transient secretion of growth hormone and insulin was achieved in vitro and in vivo. A regulated pulse of insulin secretion resulted in a transient correction of serum glucose concentrations in a mouse model of hyperglycemia. This approach may make gene therapy a viable method for delivery of polypeptides that require rapid and regulated delivery.

  12. Home Use of Day-and-Night Hybrid Closed-Loop Insulin Delivery in Suboptimally Controlled Adolescents With Type 1 Diabetes: A 3-Week, Free-Living, Randomized Crossover Trial.

    PubMed

    Tauschmann, Martin; Allen, Janet M; Wilinska, Malgorzata E; Thabit, Hood; Acerini, Carlo L; Dunger, David B; Hovorka, Roman

    2016-11-01

    This study evaluated the feasibility, safety, and efficacy of day-and-night hybrid closed-loop insulin delivery in adolescents with type 1 diabetes under free-living conditions. In an open-label randomized crossover study, 12 suboptimally controlled adolescents on insulin pump therapy (mean ± SD age 14.6 ± 3.1 years; HbA 1c 69 ± 8 mmol/mol [8.5 ± 0.7%]; duration of diabetes 7.8 ± 3.5 years) underwent two 21-day periods in which hybrid closed-loop insulin delivery was compared with sensor-augmented insulin pump therapy in random order. During the closed-loop intervention, a model predictive algorithm automatically directed insulin delivery between meals and overnight. Participants used a bolus calculator to administer prandial boluses. The proportion of time that sensor glucose was in the target range (3.9-10 mmol/L; primary end point) was increased during the closed-loop intervention compared with sensor-augmented insulin pump therapy by 18.8 ± 9.8 percentage points (mean ± SD; P < 0.001), the mean sensor glucose level was reduced by 1.8 ± 1.3 mmol/L (P = 0.001), and the time spent above target was reduced by 19.3 ± 11.3 percentage points (P < 0.001). The time spent with sensor glucose levels below 3.9 mmol/L was low and comparable between interventions (median difference 0.4 [interquartile range -2.2 to 1.3] percentage points; P = 0.33). Improved glucose control during closed-loop was associated with increased variability of basal insulin delivery (P < 0.001) and an increase in the total daily insulin dose (53.5 [39.5-72.1] vs. 51.5 [37.6-64.3] units/day; P = 0.006). Participants expressed positive attitudes and experience with the closed-loop system. Free-living home use of day-and-night closed-loop in suboptimally controlled adolescents with type 1 diabetes is safe, feasible, and improves glucose control without increasing the risk of hypoglycemia. Larger and longer studies are warranted. © 2016 by the American Diabetes Association.

  13. Therapeutics in pediatric diabetes: insulin and non-insulin approaches. Part of a series on Pediatric Pharmacology, guest edited by Gianvincenzo Zuccotti, Emilio Clementi, and Massimo Molteni.

    PubMed

    Kim, Jongoh; Kim, Se Min; Nguyen, Ha Cam Thuy; Redondo, Maria Jose

    2012-01-01

    Treatment of pediatric diabetes can be challenging. Strict glucose control can be accompanied by hypoglycemia and weight gain. Recently, there have been many developments in insulin preparations and delivery methods which make insulin levels more close to a physiologic pattern. Newly developed rapid/long acting analogues and delivery devices such as continuous subcutaneous insulin infusion (CSII, insulin pump) may reduce hypoglycemia and improve glycemic control. CSII combined with continuous glucose monitoring can achieve even better glycemic control. The closed-loop system is rapidly evolving and an artificial pancreas will be available in the near future. It is now recognized that several hormones other than insulin such as glucagon, amylin, and incretins contribute to glucose homeostasis. The role of co-adjuncts such as metformin, amylin analogues, and incretin based therapy is now emerging. Immunotherapy in a high risk population or patients in the early phase of type 1 diabetes may prevent further destruction of pancreatic β cells. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Molecular imaging analysis of intestinal insulin absorption boosted by cell-penetrating peptides by using positron emission tomography.

    PubMed

    Kamei, Noriyasu; Morishita, Mariko; Kanayama, Yousuke; Hasegawa, Koki; Nishimura, Mie; Hayashinaka, Emi; Wada, Yasuhiro; Watanabe, Yasuyoshi; Takayama, Kozo

    2010-08-17

    Molecular imaging technique by use of positron emission tomography (PET) is a noninvasive tool that allows one to quantitatively analyze the function of endogenous molecules and the pharmacokinetics of therapeutic agents in vivo. This technique is expected to be useful for evaluating the effectiveness of diverse drug delivery systems. We demonstrated previously that intestinal insulin absorption is increased significantly by coadministration of cell-penetrating peptides (CPPs), which are taken up effectively by several cells. However, the distribution behavior of insulin whose absorption is increased by CPPs is not clear. We used PET imaging and quantitatively analyzed the intestinal absorption and subsequent distribution of insulin and the effect of CPPs on its absorption and distribution. An unlabeled insulin solution containing tracer insulin, (68)Ga-DOTA-insulin, was administered with or without CPPs into a rat ileal closed loop. PET imaging showed that the CPPs, particularly D-R8 and L-penetratin, significantly increased the (68)Ga-DOTA-insulin level in the liver, kidney, and circulation. After absorption from the intestine, the (68)Ga-DOTA-insulin passed rapidly through the liver and accumulated in the kidney. The increase in the hepatic and renal distribution of (68)Ga-DOTA-insulin by each CPP coadministration was similar manner as that in intestinal absorption, suggesting that the increased accumulation of insulin in the liver and kidney induced by coadministration of CPPs was associated with the increased intestinal absorption of insulin. This is the first study to show that PET imaging enables one to quantitatively analyze the distribution behavior of intestinally absorbed insulin in several organs. This imaging methodology is likely to be useful for developing effective drug delivery systems targeted to specific organs. Copyright 2010 Elsevier B.V. All rights reserved.

  15. Artifical Pancreas

    NASA Astrophysics Data System (ADS)

    Fei, Jiangfeng

    2013-03-01

    In 2006, JDRF launched the Artificial Pancreas Project (APP) to accelerate the development of a commercially-viable artificial pancreas system to closely mimic the biological function of the pancreas individuals with insulin-dependent diabetes, particularly type 1 diabetes. By automating detection of blood sugar levels and delivery of insulin in response to those levels, an artificial pancreas has the potential to transform the lives of people with type 1 diabetes. The 6-step APP development pathway serves as JDRF's APP strategic funding plan and defines the priorities of product research and development. Each step in the plan represents incremental advances in automation beginning with devices that shut off insulin delivery to prevent episodes of low blood sugar and progressing ultimately to a fully automated ``closed loop'' system that maintains blood glucose at a target level without the need to bolus for meals or adjust for exercise.

  16. Contribution of partial pancreatectomy, systemic hormone delivery, and duct obliteration to glucose regulation in canine pancreas. Importance in pancreas transplantation.

    PubMed

    van der Burg, M P; Gooszen, H G; Guicherit, O R; Jansen, J B; Frölich, M; van Haastert, F A; Lamers, C B

    1989-09-01

    Our aim was to isolate and determine the contribution of partial pancreatectomy, systemic delivery of pancreatic hormones, and duct obliteration to glucose regulation after segmental pancreas transplantation in dogs. Fasting, postprandial, and intravenous glucose-stimulated glucose, insulin, glucagon, pancreatic polypeptide (PP), and cholecystokinin (CCK) and intravenous bombesin-stimulated PP levels were studied in beagles at three successive intervals in a crossover design. The first was 6 wk after partial (approximately 70%) pancreatectomy with intact regular enteric exocrine drainage from the duodenal pancreatic remnant, the next was 2 wk after venous transposition with systemic delivery of pancreatic hormones, and the third was 6 wk after in situ duct obliteration of the remnant. With partial pancreatectomy, K values were modestly diminished (30%), and a concomitant reduction of second-phase intravenous glucose-stimulated insulin release was observed. Other parameters were not significantly affected. Venous transposition doubled peripheral plasma levels of insulin under all conditions. Fasting glucose, PP, and CCK levels decreased slightly. Other parameters were not affected. Duct obliteration of the systemic draining pancreatic remnants seriously impaired glucose sensitivity, resulting in a 50% reduction of K values and fasting and sustained postprandial hyperglycemia (approximately 8 mM) and a 70-50% reduction (acute and overall responses, respectively) of intravenous glucose-stimulated insulin. Fasting hormone and postprandial insulin, glucagon, and CCK levels were not affected. The postprandial PP response was severely reduced, and bombesin-stimulated PP release was abolished by duct obliteration. We conclude that histological changes associated with duct obliteration are the major determinants of glucose regulation in segmental pancreas transplantation.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. A Review of the Security of Insulin Pump Infusion Systems

    PubMed Central

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-01-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. PMID:22226278

  18. A review of the security of insulin pump infusion systems.

    PubMed

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-11-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. © 2011 Diabetes Technology Society.

  19. Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.

    PubMed

    Zisser, Howard C; Bevier, Wendy; Dassau, Eyal; Jovanovic, Lois

    2010-01-01

    The objective was to quantify hydrostatic effects on continuous subcutaneous insulin infusion (CSII) pumps during basal and bolus insulin delivery. We tested CSII pumps from Medtronic Diabetes (MiniMed 512 and 515), Smiths Medical (Deltec Cozmo 1700), and Insulet (OmniPod) using insulin aspart (Novolog, Novo Nordisk). Pumps were filled and primed per manufacturer's instructions. The fluid level change was measured using an inline graduated glass pipette (100 microl) when the pipette was moved in relation to the pump (80 cm Cosmo and 110 cm Medtronics) and when level. Pumps were compared during 1 and 5 U boluses and basal insulin delivery of 1.0 and 1.5 U/h. Pronounced differences were seen during basal delivery in pumps using 80-100 cm tubing. For the 1 U/h rate, differences ranged from 74.5% of the expected delivery when the pumps were below the pipettes and pumping upward to 123.3% when the pumps were above the pipettes and pumping downward. For the 1.5 U/h rate, differences ranged from 86.7% to 117.0% when the pumps were below or above the pipettes, respectively. Compared to pumps with tubing, OmniPod performed with significantly less variation in insulin delivery. Changing position of a conventional CSII pump in relation to its tubing results in significant changes in insulin delivery. The siphon effect in the tubing may affect the accuracy of insulin delivery, especially during low basal rates. This effect has been reported when syringe pumps were moved in relation to infusion sites but has not been reported with CSII pumps. 2010 Diabetes Technology Society.

  20. Dose comparison of ultrasonic transdermal insulin delivery to subcutaneous insulin injection

    NASA Astrophysics Data System (ADS)

    Park, Eun-Joo; Dodds, Jeff; Barrie Smith, Nadine

    2010-03-01

    Prior studies have demonstrated the effectiveness of noninvasive transdermal insulin delivery using a cymbal transducer array. In this study the physiologic response to ultrasound mediated transdermal insulin delivery is compared to that of subcutaneously administered insulin. Anesthetized rats (350-550 g) were divided into four groups of four animals; one group representing ultrasound mediated insulin delivery and three representing subcutaneously administered insulin (0.15, 0.20, and 0.25 U/kg). The cymbal array was operated for 60 minutes at 20 kHz with 100 mW/cm2 spatial-peak temporal-peak intensity and a 20% duty cycle. The blood glucose level was determined at the beginning of the experiment and, following insulin administration, every 15 minutes for 90 minutes for both the ultrasound and injection groups. The change in blood glucose from baseline was compared between groups. When administered by subcutaneous injection at insulin doses of 0.15 and 0.20 U/kg, there was little change in the blood glucose levels over the 90 minute experiment. Following subcutaneous administration of insulin at a dose of 0.25 U/kg, blood glucose decreased by 190±96 mg/dl (mean±SD) at 90 minutes. The change in blood glucose following ultrasound mediated insulin delivery was -262±40 mg/dl at 90 minutes. As expected, the magnitude of change in blood glucose between the three injection groups was dependant on the dose of insulin administered. The change in blood glucose in the ultrasound group was greater than that observed in the injection groups suggesting that a higher effective dose of insulin was delivered.

  1. Needle-free injection of insulin powder: delivery efficiency and skin irritation assessment.

    PubMed

    Li, Chun-yu; Wang, Zhe-wei; Tu, Can; Wang, Jia-bo; Jiang, Bing-qian; Li, Qi; Zeng, Ling-na; Ma, Zhi-jie; Zhang, Ping; Zhao, Yan-ling; Zhang, Ya-ming; Yan, Dan; Tan, Rui; Xiao, Xiao-he

    2014-10-01

    Insulin is widely used in treating diabetes, but still needs to be administered by needle injection. This study investigated a new needle-free approach for insulin delivery. A portable powder needleless injection (PNI) device with an automatic mechanical unit was designed. Its efficiency in delivering insulin was evaluated in alloxan-induced diabetic rabbits. The skin irritation caused by the device was investigated and the results were analyzed in relation to aerodynamic parameters. Inorganic salt-carried insulin powders had hypoglycemic effects, while raw insulin powders were not effective when delivered by PNI, indicating that salt carriers play an important role in the delivery of insulin via PNI. The relative delivery efficiency of phosphate-carried insulin powder using the PNI device was 72.25%. A safety assessment test showed that three key factors (gas pressure, cylinder volume, and nozzle distance) were related to the amount of skin irritation caused by the PNI device. Optimized injection conditions caused minimal skin lesions and are safe to use in practice. The results suggest that PNI has promising prospects as a novel technology for delivering insulin and other biological drugs.

  2. Needle-free injection of insulin powder: delivery efficiency and skin irritation assessment*

    PubMed Central

    Li, Chun-yu; Wang, Zhe-wei; Tu, Can; Wang, Jia-bo; Jiang, Bing-qian; Li, Qi; Zeng, Ling-na; Ma, Zhi-jie; Zhang, Ping; Zhao, Yan-ling; Zhang, Ya-ming; Yan, Dan; Tan, Rui; Xiao, Xiao-he

    2014-01-01

    Insulin is widely used in treating diabetes, but still needs to be administered by needle injection. This study investigated a new needle-free approach for insulin delivery. A portable powder needleless injection (PNI) device with an automatic mechanical unit was designed. Its efficiency in delivering insulin was evaluated in alloxan-induced diabetic rabbits. The skin irritation caused by the device was investigated and the results were analyzed in relation to aerodynamic parameters. Inorganic salt-carried insulin powders had hypoglycemic effects, while raw insulin powders were not effective when delivered by PNI, indicating that salt carriers play an important role in the delivery of insulin via PNI. The relative delivery efficiency of phosphate-carried insulin powder using the PNI device was 72.25%. A safety assessment test showed that three key factors (gas pressure, cylinder volume, and nozzle distance) were related to the amount of skin irritation caused by the PNI device. Optimized injection conditions caused minimal skin lesions and are safe to use in practice. The results suggest that PNI has promising prospects as a novel technology for delivering insulin and other biological drugs. PMID:25294378

  3. Insulin-loaded pH-sensitive hyaluronic acid nanoparticles enhance transcellular delivery.

    PubMed

    Han, Lina; Zhao, Yuefang; Yin, Lifang; Li, Ruiming; Liang, Yang; Huang, Huan; Pan, Shirong; Wu, Chuanbin; Feng, Min

    2012-09-01

    In the present study, we developed novel insulin-loaded hyaluronic acid (HA) nanoparticles for insulin delivery. The insulin-loaded HA nanoparticles were prepared by reverse-emulsion-freeze-drying method. This method led to a homogenous population of small HA nanoparticles with average size of 182.2 nm and achieved high insulin entrapment efficiencies (approximately 95%). The pH-sensitive HA nanoparticles as an oral delivery carrier showed advantages in protecting insulin against the strongly acidic environment of the stomach, and not destroying the junction integrity of epithelial cells which promise long-term safety for chronic insulin treatment. The results of transport experiments suggested that insulin-loaded HA nanoparticles were transported across Caco-2 cell monolayers mainly via transcellular pathway and their apparent permeability coefficient from apical to basolateral had more than twofold increase compared with insulin solution. The efflux ratio of P (app) (B to A) to P (app) (A to B) less than 1 demonstrated that HA nanoparticle-mediated transport of insulin across Caco-2 cell monolayers underwent active transport. The results of permeability through the rat small intestine confirmed that HA nanoparticles significantly enhanced insulin transport through the duodenum and ileum. Diabetic rats treated with oral insulin-loaded HA nanoparticles also showed stronger hypoglycemic effects than insulin solution. Therefore, these HA nanoparticles could be a promising candidate for oral insulin delivery.

  4. Early intranasal insulin therapy halts progression of neurodegeneration: progress in Alzheimer's disease therapeutics.

    PubMed

    de la Monte, Suzanne M

    Evaluation of Craft S, Baker LD, Montine TJ, Minoshima S, Watson GS, Claxton A, et al. Intranasal Insulin Therapy for Alzheimer Disease and Amnestic Mild Cognitive Impairment: A Pilot Clinical Trial. Arch Neurol . 2011 Sep 12. Alzheimer's disease is associated with brain insulin deficiency and insulin resistance, similar to the problems in diabetes. If insulin could be supplied to the brain in the early stages of Alzheimer's, subsequent neurodegeneration might be prevented. Administering systemic insulin to elderly non-diabetics poses unacceptable risks of inadvertant hypoglycemia. However, intranasal delivery directs the insulin into the brain, avoiding systemic side-effects. This pilot study demonstrates both efficacy and safety of using intranasal insulin to treat early Alzheimer's and mild cognitive impairment, i.e. the precursor to Alzheimer's. Significant improvements in learning, memory, and cognition occured within a few months, but without intranasal insulin, brain function continued to deteriorate in measurable degrees. Intranasal insulin therapy holds promise for halting progression of Alzheimer's disease.

  5. Chemically controlled closed-loop insulin delivery.

    PubMed

    Ravaine, Valérie; Ancla, Christophe; Catargi, Bogdan

    2008-11-24

    Alternative treatments for diabetes are currently being investigated to improve both patient comfort and avoid complications due to hyperglycaemia episodes. In the absence of a cure like pancreas or beta-islets transplants, the ideal method would be an artificial "closed-loop" system able to mimic pancreas activity. This would operate continuously and automatically, causing appropriate response to losses and gains in glucose levels. Chemically controlled closed-loop insulin delivery has been explored by two main strategies. The first one consists in delivering insulin with a glucose-responsive matrix. Polymeric hydrogels that swell or shrink according to the glucose concentration allow delivering insulin doses adapted to the glucose concentration. The second strategy consists in modifying insulin itself with glucose-sensitive functional groups that trigger its activity. Recent developments made in these areas represent significant progress in terms of biocompatibility, selectivity, pharmacokinetics, and easiness of administration, as required for in vivo applications. Although some issues still have to be overcome, this field of research is promising as a possible alternative to other approaches for diabetes treatment.

  6. Injectable nano-network for glucose-mediated insulin delivery.

    PubMed

    Gu, Zhen; Aimetti, Alex A; Wang, Qun; Dang, Tram T; Zhang, Yunlong; Veiseh, Omid; Cheng, Hao; Langer, Robert S; Anderson, Daniel G

    2013-05-28

    Diabetes mellitus, a disorder of glucose regulation, is a global burden affecting 366 million people across the world. An artificial "closed-loop" system able to mimic pancreas activity and release insulin in response to glucose level changes has the potential to improve patient compliance and health. Herein we develop a glucose-mediated release strategy for the self-regulated delivery of insulin using an injectable and acid-degradable polymeric network. Formed by electrostatic interaction between oppositely charged dextran nanoparticles loaded with insulin and glucose-specific enzymes, the nanocomposite-based porous architecture can be dissociated and subsequently release insulin in a hyperglycemic state through the catalytic conversion of glucose into gluconic acid. In vitro insulin release can be modulated in a pulsatile profile in response to glucose concentrations. In vivo studies validated that these formulations provided improved glucose control in type 1 diabetic mice subcutaneously administered with a degradable nano-network. A single injection of the developed nano-network facilitated stabilization of the blood glucose levels in the normoglycemic state (<200 mg/dL) for up to 10 days.

  7. A review of the efficacy and safety of nanoparticle-based oral insulin delivery systems.

    PubMed

    Card, Jeffrey W; Magnuson, Bernadene A

    2011-12-01

    Nanotechnology is providing new and innovative means to detect, diagnose, and treat disease. In this regard, numerous nanoparticle-based approaches have been taken in an effort to develop an effective oral insulin therapy for the treatment of diabetes. This review summarizes efficacy data from studies that have evaluated oral insulin therapies in experimental models. Also provided here is an overview of the limited safety data that have been reported in these studies. To date, the most promising approaches for nanoparticle-based oral insulin therapy appear to involve the incorporation of insulin into complex multilayered nanoparticles that are mucoadhesive, biodegradable, biocompatible, and acid protected and into nanoparticles that are designed to take advantage of the vitamin B(12) uptake pathway. It is anticipated that the continued investigation and optimization of nanoparticle-based formulations for oral delivery of insulin will lead to a much sought-after noninvasive treatment for diabetes. Such investigations also may provide insight into the use of nanoparticle-based formulations for peptide- and protein-based oral treatment of other diseases and for various food-related purposes.

  8. Closed loop insulin delivery in diabetes.

    PubMed

    Battelino, Tadej; Omladič, Jasna Šuput; Phillip, Moshe

    2015-06-01

    The primary goal of type 1 diabetes treatment is attaining near-normal glucose values. This currently remains out of reach for most people with type 1 diabetes despite intensified insulin treatment in the form of insulin analogues, educational interventions, continuous glucose monitoring, and sensor augmented insulin pump. The main remaining problem is risk of hypoglycaemia, which cannot be sufficiently reduced in all patient groups. Additionally, patients' burn-out often develops with years of tedious day-to-day diabetes management, rendering available diabetes-related technology less efficient. Over the past 40 years, several attempts have been made towards computer-programmed insulin delivery in the form of closed loop, with faster developments especially in the past decade. Automated insulin delivery has reduced human error in glycaemic control and considerably lessened the burden of routine self-management. In this chapter, data from randomized controlled trials with closed-loop insulin delivery that included type 1 diabetes population are summarized, and an evidence-based vision for possible routine utilization of closed loop is provided. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Structural properties and release of insulin-loaded reverse hexagonal (HII) liquid crystalline mesophase.

    PubMed

    Mishraki-Berkowitz, Tehila; Aserin, Abraham; Garti, Nissim

    2017-01-15

    Insulin loading into the H II mesophases was examined as a function of its concentration, with addition of glycerol as a cosolvent and with addition of phosphatidylcholine (PC) as a structural stabilizer. The structural properties, the molecular interactions, the viscoelastic properties, and the dynamic behavior were investigated by SAXS, ATR-FTIR, and rheological measurements. Insulin release was then monitored and analyzed. Insulin incorporation into the H II systems shrank the cylinders as it competed with the lipids in water-bonding. Insulin interrupted the interface while increasing τ max and creating a more solid-like response. Upon addition of PC, cooperative flow behavior was detected, which is probably the reason for increase in insulin cumulative release from 28% to 52% after 300 min. In the presence of glycerol, the system was less cooperative but insulin was more compactly folded, resulting in a slight improvement in insulin release (up to 6%). Addition of both PC and glycerol caused the maximum release (55%). The addition of additives into the H II system demonstrates how structural modifications can improve insulin release, and influence future design of encapsulated drug delivery systems. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Improved systemic delivery of insulin by condensed drug loading in a dimpled suppository.

    PubMed

    Matsumoto, Akihiro; Murakami, Kayoko; Watanabe, Chie; Murakami, Masahiro

    2017-01-01

    The development of peptide therapeutics owing to the advances in biotechnology has overcome some unmet medical needs; however, the route of administration is still limited to injections. Systemic delivery of insulin via an enteral route remains a great challenge due to its instability and low mucosal permeability. In this study, we investigated the effect of drug condensation in a suppository on the efficacy of insulin after rectal administration. Suppositories with dimples are prepared by a mold method using a hard fat (Suppocire ® AM). Insulin or fluorescein isothiocyanate-dextran (molecular weight: 3,000-5,000) (FD4) as a model of a hydrophilic macromolecule was loaded in the dimples, and sealed with other lipids with different melting points. The in vitro release test showed that the time to 50% drug release depends on the melting point of the lipid for sealing but not on the number of dimples. The suppositories with one-, or three-dimple containing insulin and caprylocaproyl macrogol-8 glyceride (Labrasol ® ) were administered to rats at 0.5 U/head. The reduction in plasma glucose level was more significant for the one-dimple-type suppository than for the three-dimple-type although the one-dimple-type suppository contained less amount of Labrasol by one-third compared to the three-dimple-type. These results suggest that condensation of an insulin dose in a limited surface area of a suppository improves systemic availability via the rectal route with a reduced amount of an absorption enhancer.

  11. Methods for insulin delivery and glucose monitoring in diabetes: summary of a comparative effectiveness review.

    PubMed

    Golden, Sherita Hill; Sapir, Tamar

    2012-08-01

    Diabetes mellitus is defined as a group of metabolic diseases characterized by hyperglycemia, which when untreated can lead to long-term complications, including micro- and macrovascular complications. Tight glycemic control with intensive insulin therapy has been suggested to reduce the risk of such complications in several diabetes populations; however, such an approach can also be associated with risks and challenges. There are currently several modalities available to deliver insulin and monitor glucose levels to achieve glycemic goals in diabetic patients. In July 2012, the Agency for Healthcare Research and Quality (AHRQ) published a systematic review on the comparative effectiveness of insulin delivery systems and glucose-monitoring modalities in diabetic patients receiving intensive insulin therapy. Studies from 44 publications included in the review compared the effects of continuous subcutaneous insulin infusion (CSII) with multiple daily injections (MDI) and/or real time-continuous glucose monitoring (rt-CGM) with self-monitoring of blood glucose (SMBG) among children, adolescents, or adults with either type 1 (T1DM) or type 2 diabetes (T2DM), or pregnant women with pre-existing diabetes (either T1DM or T2DM). This comparative effectiveness review evaluated which modality results in improved glycemic control, less hypoglycemia, better quality of life, and/or improved clinical outcomes. The numerous technologies and the challenges that clinicians face when determining which patient population may benefit from different insulin delivery systems and glucose-monitoring approaches motivated AHRQ to synthesize the available information to assist health professionals in making evidence-based practice decisions for their patients. The review also delineates advances in insulin delivery and glucose-monitoring systems, practical methods to achieve tight glycemic control and strategies to minimize associated risks, as well as highlights gaps in research and areas that need to be addressed in the future.  To (a) educate health care professionals on the findings from AHRQ's 2012 comparative effectiveness review on insulin delivery and glucose-monitoring modalities in patients with diabetes; (b) apply review findings to make treatment decisions in clinical practice; and (c) identify shortcomings in the current research and future directions relating to the comparative effectiveness of insulin delivery and glucose-monitoring modalities for patients with diabetes. The AHRQ systematic review of randomized clinical trials reveals that both insulin delivery modalities (CSII and MDI) demonstrate similar effectiveness on glycemic control and severe hypoglycemia in children and adolescents with T1DM and in adults with T2DM. In adults with T1DM, hemoglobin A1c decreased more with CSII than with MDI with low strength of evidence, but one study heavily influenced these results. In children and adults with T1DM, the use of CSII was associated with improved quality of life compared with MDI, with low strength of evidence, while there was insufficient strength of evidence to make conclusions regarding the quality of life for adults with T2DM. The study investigators suggest that the modality to deliver intensive insulin therapy can be individualized to patient preference in order to maximize quality of life. On all measured outcomes, there was insufficient or low strength of evidence regarding pregnant women with pre-existing diabetes.The AHRQ investigators found studies comparing the effectiveness of glucose-monitoring modalities in individuals with T1DM only. The systematic review demonstrates that rt-CGM is associated with greater lowering of A1c compared with SMBG (high strength of evidence) without affecting the risk of severe hypoglycemia (low strength of evidence) or quality of life (low strength of evidence) in nonpregnant individuals with T1DM, particularly when compliance with device use is high. Additional findings suggest that the use of sensor-augmented insulin pumps (rt-CGM + CSII) is superior to the use of MDI/SMBG use in lowering A1c in nonpregnant individuals with T1DM (moderate strength of evidence). Comparison of other outcome measures did not yield firm conclusions due to low or insufficient evidence.

  12. Reduction in duration of hypoglycemia by automatic suspension of insulin delivery: the in-clinic ASPIRE study.

    PubMed

    Garg, Satish; Brazg, Ronald L; Bailey, Timothy S; Buckingham, Bruce A; Slover, Robert H; Klonoff, David C; Shin, John; Welsh, John B; Kaufman, Francine R

    2012-03-01

    The efficacy of automatic suspension of insulin delivery in induced hypoglycemia among subjects with type 1 diabetes was evaluated. In this randomized crossover study, subjects used a sensor-augmented insulin pump system with a low glucose suspend (LGS) feature that automatically stops insulin delivery for 2 h following a sensor glucose (SG) value ≤70 mg/dL. Subjects fasted overnight and exercised until their plasma glucose (measured with the YSI 2300 STAT Plus™ glucose and lactate analyzer [YSI Life Sciences, Yellow Springs, OH]) value reached ≤85 mg/dL on different occasions separated by washout periods lasting 3-10 days. Exercise sessions were done with the LGS feature turned on (LGS-On) or with continued insulin delivery regardless of SG value (LGS-Off). The order of LGS-On and LGS-Off sessions was randomly assigned. YSI glucose data were used to compare the duration and severity of hypoglycemia from successful LGS-On and LGS-Off sessions and to estimate the risk of rebound hyperglycemia after pump suspension. Fifty subjects attempted 134 sessions, 98 of which were successful. The mean±SD hypoglycemia duration was less during LGS-On than during LGS-Off sessions (138.5±76.68 vs. 170.7±75.91 min, P=0.006). During LGS-On compared with LGS-Off sessions, mean nadir YSI glucose was higher (59.5±5.72 vs. 57.6±5.69 mg/dL, P=0.015), as was mean end-observation YSI glucose (91.4±41.84 vs. 66.2±13.48 mg/dL, P<0.001). Most (53.2%) end-observation YSI glucose values in LGS-On sessions were in the 70-180 mg/dL range, and none was >250 mg/dL. Automatic suspension of insulin delivery significantly reduced the duration and severity of induced hypoglycemia without causing rebound hyperglycemia.

  13. Vascular Function, Insulin Action and Exercise: An Intricate Interplay

    PubMed Central

    Zheng, Chao; Liu, Zhenqi

    2015-01-01

    Insulin enhances the compliance of conduit arteries, relaxes resistance arterioles to increase tissue blood flow and dilates precapillary arterioles to expand muscle microvascular blood volume. These actions are impaired in the insulin resistant states. Exercise ameliorates endothelial dysfunction and improves insulin responses in insulin resistant patients, but the precise underlying mechanisms remain unclear. The microvasculature critically regulates insulin action in muscle by modulating insulin delivery to the capillaries nurturing the myocytes and trans-endothelial insulin transport. Recent data suggest that exercise may exert its insulin-sensitizing effect via recruiting muscle microvasculature to increase insulin delivery to and action in muscle. The current review focuses on how the interplay among exercise, insulin action and the vasculature contributes to exercise-mediated insulin sensitization in muscle. PMID:25735473

  14. Biosynthesis of insulin-silk fibroin nanoparticles conjugates and in vitro evaluation of a drug delivery system

    NASA Astrophysics Data System (ADS)

    Yan, Hai-Bo; Zhang, Yu-Qing; Ma, Yong-Lei; Zhou, Li-Xia

    2009-11-01

    Silk fibroin derived from Bombyx mori is a biomacromolecular protein with outstanding biocompatibility. When it was dissolved in highly concentrated CaCl2 solution and then the mixture of the protein and salt was subjected to desalting treatments for long time in flowing water, the resulting liquid silk was water-soluble polypeptides with different molecular masses, ranging from 8 to 70 kDa. When the liquid silk was introduced rapidly into acetone, silk protein nanoparticles with a range of 40-120 nm in diameter could be obtained. The crystalline silk nanoparticles could be conjugated covalently with insulin alone with cross-linking reagent glutaraldehyde. In vitro properties of the insulin-silk fibroin nanoparticles (Ins-SFN) bioconjugates were determined by Enzyme-Linked Immunosorbent Assay (ELISA). The optimal conditions for the biosynthesis of Ins-SFN bioconjugates were investigated. The Ins-SFN constructs obtained by 8 h of covalent cross-linking with 0.7% cross-linking reagent and the proportion of insulin and SFN being 30 IU: 15 mg showed much higher recoveries (90-115%). When insulin was coupled covalently with silk nanoparticles, the resistance of the modified insulin to trypsin digestion and in vitro stability in human serum were greatly enhanced as compared with insulin alone. The results in human serum indicated that the half-life in vitro of the biosynthesized Ins-SFN derivatives was about 2.5 times more than that of native insulin. Therefore, the silk protein nanoparticles have the potential values for being studied and developed as a new bioconjugate for enzyme/polypeptide drug delivery system.

  15. Oral delivery of insulin for treatment of diabetes: status quo, challenges and opportunities.

    PubMed

    Wong, Chun Y; Martinez, Jorge; Dass, Crispin R

    2016-09-01

    Diabetes mellitus is characterised by progressive β-cell destruction and loss of function, or loss of ability of tissues to respond to insulin. Daily subcutaneous insulin injection is standard management for people with diabetes, although patient compliance is hard to achieve due to the inconvenience of injections, so other forms of delivery are being tested, including oral administration. This review summarises the developments in oral insulin administration. The PubMed database was consulted to compile this review comparing conventional subcutaneous injection of insulin to the desired oral delivery. Oral administration of insulin has potential benefits in reducing pain and chances of skin infection, improving the portal levels of insulin and avoiding side effects such as hyperinsulinemia, weight gain and hypoglycaemia. Although oral delivery of insulin is an ideal administration route for patients with diabetes, several physiological barriers have to be overcome. An expected low oral bioavailability can be attributed to its high molecular weight, susceptibility to enzymatic proteolysis and low diffusion rate across the mucin barrier. Strategies for increasing the bioavailability of oral insulin include the use of enzyme inhibitors, absorption enhancers, mucoadhesive polymers and chemical modification for endogenous receptor-mediated absorption. These may help significantly increase patient compliance and disease management. © 2016 Royal Pharmaceutical Society.

  16. Self-assembling bubble carriers for oral protein delivery.

    PubMed

    Chuang, Er-Yuan; Lin, Kun-Ju; Lin, Po-Yen; Chen, Hsin-Lung; Wey, Shiaw-Pyng; Mi, Fwu-Long; Hsiao, Hsu-Chan; Chen, Chiung-Tong; Sung, Hsing-Wen

    2015-09-01

    Successful oral delivery of therapeutic proteins such as insulin can greatly improve the quality of life of patients. This study develops a bubble carrier system by loading diethylene triamine pentaacetic acid (DTPA) dianhydride, a foaming agent (sodium bicarbonate; SBC), a surfactant (sodium dodecyl sulfate; SDS), and a protein drug (insulin) in an enteric-coated gelatin capsule. Following oral administration to diabetic rats, the intestinal fluid that has passed through the gelatin capsule saturates the mixture; concomitantly, DTPA dianhydride produces an acidic environment, while SBC decomposes to form CO2 bubbles at acidic pH. The gas bubbles grow among the surfactant molecules (SDS) owing to the expansion of the generated CO2. The walls of the CO2 bubbles consist of a self-assembled film of water that is in nanoscale and may serve as a colloidal carrier to transport insulin and DTPA. The grown gas bubbles continue to expand until they bump into the wall and burst, releasing their transported insulin, DTPA, and SDS into the mucosal layer. The released DTPA and SDS function as protease inhibitors to protect the insulin molecules as well as absorption enhancers to augment their epithelial permeability and eventual absorption into systemic circulation, exerting their hypoglycemic effects. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Potential of single cationic amino acid molecule "Arginine" for stimulating oral absorption of insulin.

    PubMed

    Kamei, Noriyasu; Khafagy, El-Sayed; Hirose, Jun; Takeda-Morishita, Mariko

    2017-04-15

    We have reported that cell-penetrating peptides, such as oligoarginine, act as powerful absorption enhancers for the development of oral insulin delivery systems. However, the minimal essential sequence of oligoarginine that stimulates intestinal insulin absorption remains unclear. Therefore, the present study was conducted to clarify this minimum sequence of oligoarginine and to examine the effect of single cationic amino acid arginine on the intestinal and oral absorption of insulin. The results demonstrated that a remarkable enhancement of intestinal insulin absorption was observed after coadministration of insulin with l-arginine. The efficacy of d-forms of oligoarginine/arginine tended to decrease with a decreasing number of amino acid residues, whereas the effect of l-arginine was the strongest of any of the l-forms of oligoarginine/arginine. Interestingly, the effect of l-arginine was stronger than that of d-arginine at various concentrations, and the effect of other cationic amino acids such as lysine and histidine was relatively lower than that of arginine. In addition, no leakage of lactate dehydrogenase from the intestinal epithelium and no change in the transepithelial electrical resistance of a Caco-2 cell monolayer were detected after administration of l-arginine as the single amino acid, which suggests that there were no undesirable effects of arginine on the integrity of cell membranes and paracellular tight junctions. Oral administration study in mice demonstrated that the stronger hypoglycemic effects were observed after coadministration of insulin with l-arginine. In this study, we found that arginine is a key cationic amino acid for delivering insulin across intestinal epithelial barriers and hopefully accelerating the clinical development of oral insulin delivery systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Transdermal drug delivery

    PubMed Central

    Prausnitz, Mark R.; Langer, Robert

    2009-01-01

    Transdermal drug delivery has made an important contribution to medical practice, but has yet to fully achieve its potential as an alternative to oral delivery and hypodermic injections. First-generation transdermal delivery systems have continued their steady increase in clinical use for delivery of small, lipophilic, low-dose drugs. Second-generation delivery systems using chemical enhancers, non-cavitational ultrasound and iontophoresis have also resulted in clinical products; the ability of iontophoresis to control delivery rates in real time provides added functionality. Third-generation delivery systems target their effects to skin’s barrier layer of stratum corneum using microneedles, thermal ablation, microdermabrasion, electroporation and cavitational ultrasound. Microneedles and thermal ablation are currently progressing through clinical trials for delivery of macromolecules and vaccines, such as insulin, parathyroid hormone and influenza vaccine. Using these novel second- and third-generation enhancement strategies, transdermal delivery is poised to significantly increase impact on medicine. PMID:18997767

  19. pH-sensitive poly(lactide-co-glycolide) nanoparticle composite microcapsules for oral delivery of insulin.

    PubMed

    Sun, Shaoping; Liang, Na; Yamamoto, Hiromitsu; Kawashima, Yoshiaki; Cui, Fude; Yan, Pengfei

    2015-01-01

    This study proposes a new concept of pH-sensitive poly(lactide-co-glycolide) (PLGA) nanoparticle composite microcapsules for oral delivery of insulin. Firstly, insulin-sodium oleate complex was prepared by the hydrophobic ion pairing method and then encapsulated into PLGA nanoparticles by the emulsion solvent diffusion method. In order to reduce the burst release of insulin from PLGA nanoparticles and deliver insulin to specific gastrointestinal regions, hence to enhance bioavailability of insulin, the PLGA nanoparticles were further encapsulated into Eudragit(®) FS 30D to prepare PLGA nanoparticle composite microcapsules by organic spray-drying method. The preparation was evaluated in vitro and in vivo, and the absorption mechanism was discussed. The in vitro drug release studies revealed that the drug release was pH dependent, and the in vivo results demonstrated that the formulation of PLGA nanoparticle composite microcapsules was an effective candidate for oral insulin delivery.

  20. Budget impact analysis of insulin therapies and associated delivery systems.

    PubMed

    Lee, Lauren J; Smolen, Lee J; Klein, Timothy M; Foster, Shonda A; Whiteman, Doug; Jorgenson, James A; Hultgren, Steve

    2012-06-01

    A budget impact analysis of insulin therapies and associated delivery systems is presented. Based on inputted procurement totals, per-item costs (based on 2011 average wholesale price), insulin distribution system (floor stock or individual patient supply), waste, and treatment protocols for a specified time frame, the budget impact model approximated the number of patients treated with subcutaneous insulin, costs, utilization, waste, and injection mechanism (pen safety needle or syringe) costs. To calculate net changes, results of one-year 3-mL vial use were subtracted from one-year 10-mL vial or 3-mL pen use. Switching from a 10-mL vial to a 3-mL vial was associated with reductions in both costs and waste. The net reductions in costs and waste ranged from $15,482 and 120,000 IU, respectively, for floor-stock 10-mL vial to floor-stock 3-mL vial conversion to $871,548 and 6,750,000 IU, respectively, for individual patient supply 10-mL vial to floor-stock 3-mL vial conversion. Switching from floor-stock 10-mL vials to individual patient supply 3-mL vials increased costs and waste by $164,659 and 1,275,000 IU, respectively. Converting from individual patient supply 3-mL pens to individual patient supply 3-mL vials reduced costs by $117,236 but did not decrease waste. A budget impact analysis of the conversion of either 10-mL insulin vials or 3-mL insulin pens to 3-mL insulin vials found reductions in both cost and waste, except when converting from floor-stock 10-mL vials to individual patient supply 3-mL vials.

  1. Therapeutics of diabetes mellitus: focus on insulin analogues and insulin pumps.

    PubMed

    Valla, Vasiliki

    2010-01-01

    Inadequately controlled diabetes accounts for chronic complications and increases mortality. Its therapeutic management aims in normal HbA1C, prandial and postprandial glucose levels. This review discusses diabetes management focusing on the latest insulin analogues, alternative insulin delivery systems and the artificial pancreas. Intensive insulin therapy with multiple daily injections (MDI) allows better imitation of the physiological rhythm of insulin secretion. Longer-acting, basal insulin analogues provide concomitant improvements in safety, efficacy and variability of glycaemic control, followed by low risks of hypoglycaemia. Continuous subcutaneous insulin infusion (CSII) provides long-term glycaemic control especially in type 1 diabetic patients, while reducing hypoglycaemic episodes and glycaemic variability. Continuous subcutaneous glucose monitoring (CGM) systems provide information on postprandial glucose excursions and nocturnal hypo- and/or hyperglycemias. This information enhances treatment options, provides a useful tool for self-monitoring and allows safer achievement of treatment targets. In the absence of a cure-like pancreas or islets transplants, artificial "closed-loop" systems mimicking the pancreatic activity have been also developed. Individualized treatment plans for insulin initiation and administration mode are critical in achieving target glycaemic levels. Progress in these fields is expected to facilitate and improve the quality of life of diabetic patients.

  2. Transdermal Protein Delivery Using Choline and Geranate (CAGE) Deep Eutectic Solvent.

    PubMed

    Banerjee, Amrita; Ibsen, Kelly; Iwao, Yasunori; Zakrewsky, Michael; Mitragotri, Samir

    2017-08-01

    Transdermal delivery of peptides and other biological macromolecules is limited due to skin's inherent low permeability. Here, the authors report the use of a deep eutectic solvent, choline and geranate (CAGE), to enhance topical delivery of proteins such as bovine serum albumin (BSA, molecular weight: ≈66 kDa), ovalbumin (OVA, molecular weight: ≈45 kDa) and insulin (INS, molecular weight: 5.8 kDa). CAGE enhances permeation of BSA, OVA, and insulin into porcine skin ex vivo, penetrating deep into the epidermis and dermis. Studies using tritium-labeled BSA and fluorescein isothiocyanate labeled insulin show significantly enhanced delivery of proteins into and across porcine skin, penetrating the skin in a time-dependent manner. Fourier transform IR spectra of porcine stratum corneum (SC) samples before and after incubation in CAGE show a reduction in peak area attributed to SC lipid content, suggesting lipid extraction from the SC. Circular dichroism confirms that CAGE does not affect insulin's secondary conformation. In vivo studies in rats show that topical application of 10 U insulin dispersed in CAGE (25 U kg -1 insulin dose) leads to a highly significant 40% drop in blood glucose levels in 4 h that is relatively sustained for 12 h. Taken together, these studies demonstrate that CAGE is a promising vehicle for transdermal delivery of therapeutic proteins; specifically, as a noninvasive delivery alternative to injectable insulin for the treatment of diabetes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Safe Glycemic Management during Closed-Loop Treatment of Type 1 Diabetes: The Role of Glucagon, Use of Multiple Sensors, and Compensation for Stress Hyperglycemia

    PubMed Central

    Ward, W Kenneth; Castle, Jessica R; Youssef, Joseph El

    2011-01-01

    Patients with type 1 diabetes mellitus (T1DM) must make frequent decisions and lifestyle adjustments in order to manage their disorder. Automated treatment would reduce the need for these self-management decisions and reduce the risk for long-term complications. Investigators in the field of closed-loop glycemic control systems are now moving from inpatient to outpatient testing of such systems. As outpatient systems are developed, the element of safety increases in importance. One such concern is the risk for hypoglycemia, due in part to the delayed onset and prolonged action duration of currently available subcutaneous insulin preparations. We found that, as compared to an insulin-only closed-loop system, a system that also delivers glucagon when needed led to substantially less hypoglycemia. Though the capability of glucagon delivery would mandate the need for a second hormone chamber, glucagon in small doses is tolerated very well. People with T1DM often develop hyperglycemia from emotional stress or medical stress. Automated closed-loop systems should be able to detect such changes in insulin sensitivity and adapt insulin delivery accordingly. We recently verified the adaptability of a model-based closed-loop system in which the gain factors that govern a proportional-integral-derivative-like system are adjusted according to frequently measured insulin sensitivity. Automated systems can be tested by physical exercise to increase glucose uptake and insulin sensitivity or by administering corticosteroids to reduce insulin sensitivity. Another source of risk in closed-loop systems is suboptimal performance of amperometric glucose sensors. Inaccuracy can result from calibration error, biofouling, and current drift. We found that concurrent use of more than one sensor typically leads to better sensor accuracy than use of a single sensor. For example, using the average of two sensors substantially reduces the proportion of large sensor errors. The use of more than two allows the use of voting algorithms, which can temporarily exclude a sensor whose signal is outlying. Elements such as the use of glucagon to minimize hypoglycemia, adaptation to changes in insulin sensitivity, and sensor redundancy will likely increase safety during outpatient use of closed-loop glycemic control systems. PMID:22226254

  4. The effect of nanoparticle size on the ability to cross the blood-brain barrier: an in vivo study.

    PubMed

    Betzer, Oshra; Shilo, Malka; Opochinsky, Renana; Barnoy, Eran; Motiei, Menachem; Okun, Eitan; Yadid, Gal; Popovtzer, Rachela

    2017-07-01

    Our goal was to develop an efficient nanoparticle-based system that can overcome the restrictive mechanism of the blood-brain barrier (BBB) by targeting insulin receptors and would thus enable drug delivery to the brain. Insulin-coated gold nanoparticles (INS-GNPs) were synthesized to serve as a BBB transport system. The effect of nanoparticle size (20, 50 and 70 nm) on their ability to cross the BBB was quantitatively investigated in Balb/C mice. The most widespread biodistribution and highest accumulation within the brain were observed using 20 nm INS-GNPs, 2 h post injection. In vivo CT imaging revealed that particles migrated to specific brain regions, which are involved in neurodegenerative and neuropsychiatric disorders. These findings promote the optimization of nanovehicles for transport of drugs through the BBB. The insulin coating of the particles enabled targeting of specific brain regions, suggesting the potential use of INS-GNPs for delivery of various treatments for brain-related disorders.

  5. Pitfalls of insulin pump clocks: technical glitches that may potentially affect medical care in patients with diabetes.

    PubMed

    Aldasouqi, Saleh A; Reed, Amy J

    2014-11-01

    The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients' visits, and should remind their patients to always verify these settings. © 2014 Diabetes Technology Society.

  6. Pitfalls of Insulin Pump Clocks

    PubMed Central

    Reed, Amy J.

    2014-01-01

    The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients’ visits, and should remind their patients to always verify these settings. PMID:25355713

  7. In vivo dual-delivery of glucagon like peptide-1 (GLP-1) and dipeptidyl peptidase-4 (DPP4) inhibitor through composites prepared by microfluidics for diabetes therapy

    NASA Astrophysics Data System (ADS)

    Araújo, F.; Shrestha, N.; Gomes, M. J.; Herranz-Blanco, B.; Liu, D.; Hirvonen, J. J.; Granja, P. L.; Santos, H. A.; Sarmento, B.

    2016-05-01

    Oral delivery of proteins is still a challenge in the pharmaceutical field. Nanoparticles are among the most promising carrier systems for the oral delivery of proteins by increasing their oral bioavailability. However, most of the existent data regarding nanosystems for oral protein delivery is from in vitro studies, lacking in vivo experiments to evaluate the efficacy of these systems. Herein, a multifunctional composite system, tailored by droplet microfluidics, was used for dual delivery of glucagon like peptide-1 (GLP-1) and dipeptidyl peptidase-4 inhibitor (iDPP4) in vivo. Oral delivery of GLP-1 with nano- or micro-systems has been studied before, but the simultaneous nanodelivery of GLP-1 with iDPP4 is a novel strategy presented here. The type 2 diabetes mellitus (T2DM) rat model, induced through the combined administration of streptozotocin and nicotinamide, a non-obese model of T2DM, was used. The combination of both drugs resulted in an increase in the hypoglycemic effects in a sustained, but prolonged manner, where the iDPP4 improved the therapeutic efficacy of GLP-1. Four hours after the oral administration of the system, blood glucose levels were decreased by 44%, and were constant for another 4 h, representing half of the glucose area under the curve when compared to the control. An enhancement of the plasmatic insulin levels was also observed 6 h after the oral administration of the dual-drug composite system and, although no statistically significant differences existed, the amount of pancreatic insulin was also higher. These are promising results for the oral delivery of GLP-1 to be pursued further in a chronic diabetic model study.

  8. Novel preparation of PLGA/HP55 nanoparticles for oral insulin delivery

    NASA Astrophysics Data System (ADS)

    Wu, Zhi Min; Ling, Li; Zhou, Li Ying; Guo, Xin Dong; Jiang, Wei; Qian, Yu; Luo, Kathy Qian; Zhang, Li Juan

    2012-06-01

    The aim of the present study was to develop the PLGA/HP55 nanoparticles with improved hypoglycemic effect for oral insulin delivery. The insulin-loaded PLGA/HP55 nanoparticles were produced by a modified multiple emulsion solvent evaporation method. The physicochemical characteristics, in vitro release of insulin, and in vivo efficacy in diabetic rats of the nanoparticles were evaluated. The insulin encapsulation efficiency was up to 94%, and insulin was released in a pH-dependent manner under simulated gastrointestinal conditions. When administered orally (50 IU/kg) to diabetic rats, the nanoparticles can decrease rapidly the blood glucose level with a maximal effect between 1 and 8 h. The relative bioavailability compared with subcutaneous injection (5 IU/kg) in diabetic rats was 11.3% ± 1.05%. This effect may be explained by the fast release of insulin in the upper intestine, where it is better absorbed by the high gradient concentration of insulin than other regions. These results show that the PLGA/HP55 nanoparticles developed in the study might be employed as a potential method for oral insulin delivery.

  9. Hypoglycaemic effect of a novel insulin buccal formulation on rabbits.

    PubMed

    Xu, Hui-Bi; Huang, Kai-Xun; Zhu, Yu-Shan; Gao, Qiu-Hua; Wu, Qing-Zhi; Tian, Wei-Qun; Sheng, Xi-Qun; Chen, Ze-Xian; Gao, Zhong-Hong

    2002-11-01

    Transmucosal delivery is a suitable route for insulin non-injection administration. In this study, the hypoglycaemic effect of INSULIN BUCCAL SPRAY (IBS), a formulation with soybean lecithin and propanediol combined as absorption enhancer for insulin on diabetic rabbits and rats, were investigated. The hypoglycaemic rate was calculated and the pharmacodynamics and pharmacokinetics of the formulation in rabbits were studied. The results show that when the diabetic rabbits were administrated with IBS in dosages of 0.5, 1.5 and 4.5Ukg(-1), the blood glucose level decreased significantly compared with that of the control group and the hypoglycaemic effect lasted over 5h. The blood glucose decreasing rates are 22.4, 48.1 and 53.5%, respectively. The average bioavailability of IBS by buccal delivery versus subcutaneous injection is 29.2%. Meanwhile, the diabetic rats were administrated with IBS in dosages of 1.0, 3.0 and 9.0Ukg(-1), the blood glucose level decreased significantly compared with that of the control group and the hypoglycaemic effect lasted over 4h. The blood glucose decreasing rates are 24.6, 47.5 and 59.6%, respectively. Furthermore, the penetration of fluorescein isothiocyanate (FITC)-labelled insulin through rabbit buccal mucosa was investigated by scanning the distribution of the fluorescent probe in the epithelium using confocal laser scanning microscopy. The results revealed that FITC-insulin can pass through the buccal mucosa promoted by the enhancer and the passage of insulin across the epithelium includes both intracellular and paracellular routes. From the rabbit and rat experimental results showed that IBS is an effective buccal delivery system, which is promising for clinical trial and the future clinical application.

  10. Pharmacokinetic Model of the Transport of Fast-Acting Insulin From the Subcutaneous and Intradermal Spaces to Blood.

    PubMed

    Lv, Dayu; Kulkarni, Sandip D; Chan, Alice; Keith, Stephen; Pettis, Ron; Kovatchev, Boris P; Farhi, Leon S; Breton, Marc D

    2015-07-01

    Pharmacokinetic (PK) models describing the transport of insulin from the injection site to blood assist clinical decision making and are part of in silico platforms for developing and testing of insulin delivery strategies for treatment of patients with diabetes. The ability of these models to accurately describe all facets of the in vivo insulin transport is therefore critical for their application. Here, we propose a new model of fast-acting insulin analogs transport from the subcutaneous and intradermal spaces to blood that can accommodate clinically observed biphasic appearance and delayed clearance of injected insulin, 2 phenomena that are not captured by existing PK models. To develop the model we compare 9 insulin transport PK models which describe hypothetical insulin delivery pathways potentially capable of approximating biphasic appearance of exogenous insulin. The models are tested with respect to their ability to describe clinical data from 10 healthy volunteers which received 1 subcutaneous and 2 intradermal insulin injections on 3 different occasions. The optimal model, selected based on information and posterior identifiability criteria, assumes that insulin is delivered at the administrative site and is then transported to the bloodstream via 2 independent routes (1) diffusion-like process to the blood and (2) combination of diffusion-like processes followed by an additional compartment before entering the blood. This optimal model accounts for biphasic appearance and delayed clearance of exogenous insulin. It agrees better with the clinical data as compared to commonly used models and is expected to improve the in silico development and testing of insulin treatment strategies, including artificial pancreas systems. © 2015 Diabetes Technology Society.

  11. Proximity to Delivery Alters Insulin Sensitivity and Glucose Metabolism in Pregnant Mice.

    PubMed

    Musial, Barbara; Fernandez-Twinn, Denise S; Vaughan, Owen R; Ozanne, Susan E; Voshol, Peter; Sferruzzi-Perri, Amanda N; Fowden, Abigail L

    2016-04-01

    In late pregnancy, maternal insulin resistance occurs to support fetal growth, but little is known about insulin-glucose dynamics close to delivery. This study measured insulin sensitivity in mice in late pregnancy at day 16 (D16) and near term at D19. Nonpregnant (NP) and pregnant mice were assessed for metabolite and hormone concentrations, body composition by DEXA, tissue insulin signaling protein abundance by Western blotting, glucose tolerance and utilization, and insulin sensitivity using acute insulin administration and hyperinsulinemic-euglycemic clamps with [(3)H]glucose infusion. Whole-body insulin resistance occurred in D16 pregnant dams in association with basal hyperinsulinemia, insulin-resistant endogenous glucose production, and downregulation of several proteins in hepatic and skeletal muscle insulin signaling pathways relative to NP and D19 values. Insulin resistance was less pronounced at D19, with restoration of NP insulin concentrations, improved hepatic insulin sensitivity, and increased abundance of hepatic insulin signaling proteins. At D16, insulin resistance at whole-body, tissue, and molecular levels will favor fetal glucose acquisition, while improved D19 hepatic insulin sensitivity will conserve glucose for maternal use in anticipation of lactation. Tissue sensitivity to insulin, therefore, alters differentially with proximity to delivery in pregnant mice, with implications for human and other species. © 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  12. Transdermal drug delivery of insulin with ultradeformable carriers.

    PubMed

    Cevc, Gregor

    2003-01-01

    For a long time, scientists believed that macromolecules can only be introduced through the skin with a hypodermic needle or some other harsh treatment that locally damages the skin barrier. It is now clear that macromolecules can be administered epicutaneously, so that insulin, for example, can exhibit therapeutic effects in patients with type 1 diabetes mellitus. When carriers are employed for the purpose, the drugs must be associated with specifically designed vehicles in the form of highly deformable aggregates and applied on the skin non-occlusively. Using such optimised carriers, so-called Transfersomes, ensures reproducible and efficient transcutaneous carrier and drug transport. Insulin-loaded Transfersomes, for example, can deliver the drug through the non-compromised skin barrier with a reproducible drug effect that resembles closely that of an ultralente insulin injected under the skin; the pharmacokinetic and pharmacodynamic properties of the injected and transdermal insulin are also comparable. The efficacy of transcutaneously delivered insulin in Transfersomes is not affected by the previous therapy, similar results having been measured in patients normally receiving intensified insulin therapy or a continuous subcutaneous infusion of insulin solution. Systemic normoglycaemia that lasts at least 16 hours has been achieved using a single non-invasive, epicutaneous administration of insulin in Transfersomes. Experience with other drugs suggests that the biodistribution of injected and transcutaneously delivered drugs can be very similar. This notwithstanding, Transfersomes can be designed and applied so as to mediate site-specific drug delivery into peripheral musculoskeletal tissues or into the skin, as may be desired.

  13. Importance of integrating nanotechnology with pharmacology and physiology for innovative drug delivery and therapy - an illustration with firsthand examples.

    PubMed

    Zhang, Rui Xue; Li, Jason; Zhang, Tian; Amini, Mohammad A; He, Chunsheng; Lu, Brian; Ahmed, Taksim; Lip, HoYin; Rauth, Andrew M; Wu, Xiao Yu

    2018-05-01

    Nanotechnology has been applied extensively in drug delivery to improve the therapeutic outcomes of various diseases. Tremendous efforts have been focused on the development of novel nanoparticles and delineation of the physicochemical properties of nanoparticles in relation to their biological fate and functions. However, in the design and evaluation of these nanotechnology-based drug delivery systems, the pharmacology of delivered drugs and the (patho-)physiology of the host have received less attention. In this review, we discuss important pharmacological mechanisms, physiological characteristics, and pathological factors that have been integrated into the design of nanotechnology-enabled drug delivery systems and therapies. Firsthand examples are presented to illustrate the principles and advantages of such integrative design strategies for cancer treatment by exploiting 1) intracellular synergistic interactions of drug-drug and drug-nanomaterial combinations to overcome multidrug-resistant cancer, 2) the blood flow direction of the circulatory system to maximize drug delivery to the tumor neovasculature and cells overexpressing integrin receptors for lung metastases, 3) endogenous lipoproteins to decorate nanocarriers and transport them across the blood-brain barrier for brain metastases, and 4) distinct pathological factors in the tumor microenvironment to develop pH- and oxidative stress-responsive hybrid manganese dioxide nanoparticles for enhanced radiotherapy. Regarding the application in diabetes management, a nanotechnology-enabled closed-loop insulin delivery system was devised to provide dynamic insulin release at a physiologically relevant time scale and glucose levels. These examples, together with other research results, suggest that utilization of the interplay of pharmacology, (patho-)physiology and nanotechnology is a facile approach to develop innovative drug delivery systems and therapies with high efficiency and translational potential.

  14. Factors determining insulin requirements in women with type 1 diabetes mellitus during pregnancy: a review

    PubMed Central

    McIntyre, Harold David; Callaway, Leonie

    2014-01-01

    Most women with type 1 diabetes mellitus (T1DM) have increased insulin requirements during pregnancy. However, a minority of women have a fall in insulin requirements. When this occurs in late gestation, it often provokes concern regarding possible compromise of the feto-placental unit. In some centres, this is considered as an indication for delivery, including premature delivery. There are, however, many other factors that affect insulin requirements in pregnancy in women with type 1 diabetes mellitus and the decline in insulin requirements may represent a variant of normal pregnancy. If there is no underlying pathological process, expedited delivery in these women is not warranted and confers increased risks to the newborn. We will explore the factors affecting insulin requirements in gestation in this review. We will also discuss some novel concepts regarding beta-cell function in pregnancy. PMID:27512424

  15. pH-sensitive poly(lactide-co-glycolide) nanoparticle composite microcapsules for oral delivery of insulin

    PubMed Central

    Sun, Shaoping; Liang, Na; Yamamoto, Hiromitsu; Kawashima, Yoshiaki; Cui, Fude; Yan, Pengfei

    2015-01-01

    This study proposes a new concept of pH-sensitive poly(lactide-co-glycolide) (PLGA) nanoparticle composite microcapsules for oral delivery of insulin. Firstly, insulin–sodium oleate complex was prepared by the hydrophobic ion pairing method and then encapsulated into PLGA nanoparticles by the emulsion solvent diffusion method. In order to reduce the burst release of insulin from PLGA nanoparticles and deliver insulin to specific gastrointestinal regions, hence to enhance bioavailability of insulin, the PLGA nanoparticles were further encapsulated into Eudragit® FS 30D to prepare PLGA nanoparticle composite microcapsules by organic spray-drying method. The preparation was evaluated in vitro and in vivo, and the absorption mechanism was discussed. The in vitro drug release studies revealed that the drug release was pH dependent, and the in vivo results demonstrated that the formulation of PLGA nanoparticle composite microcapsules was an effective candidate for oral insulin delivery. PMID:25999713

  16. Novel PLGA-based nanoparticles for the oral delivery of insulin.

    PubMed

    Malathi, Sampath; Nandhakumar, Perumal; Pandiyan, Velayudham; Webster, Thomas J; Balasubramanian, Sengottuvelan

    2015-01-01

    Insulin is the drug therapy for patients with insulin-dependent diabetes mellitus. A number of attempts have been made in the past to overcome the problems associated with the oral delivery of insulin, but with little success. Orally administered insulin has encountered with many difficulties such as rapid degradation and poor intestinal absorption. The potential use of D-α-tocopherol poly(ethylene glycol) 1000 succinate (TPGS)-emulsified poly(ethylene glycol) (PEG)-capped poly(lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) was investigated for sustained delivery of insulin (IS). To investigate the efficacy of TPGS-emulsified PEG-capped PLGA NPs (TPPLG NPs) as a potential drug carrier for the oral delivery of insulin. A series of biodegradable low-molecular-weight PLGA (80/20 [PLG4] and 70/30 [PLG6]) copolymers were synthesized by melt polycondensation. The commercial insulin-loaded TPGS-emulsified PEG-capped PLGA NPs (ISTPPLG NPs) were synthesized by water-oil-water emulsion solvent evaporation method. The physical and chemical properties of PLGA copolymers, particle size, zeta potential, and morphology of the NPs were examined. The in vivo studies of ISTPPLG NPs were carried out in diabetic rats by oral administration. The maximum encapsulation efficiency of ISTPPLG6 NPs was 78.6% ± 1.2%, and the mean diameter of the NPs was 180 ± 20 nm. The serum glucose level was significantly (twofold) decreased on treatment with ISTPPLG NPs, and there was a threefold decrease with insulin-loaded PLGA (70/30) NPs when compared to that of free insulin-treated diabetic rats. The results show that the oral administration of ISTPPLG6 NPs is an effective method of reducing serum glucose level for a period of 24 hours. Histopathological studies reveal that ISTPPLG NPs could restore the damage caused by streptozotocin in the liver, kidneys, and pancreas, indicating its biocompatibility and regenerative effects. ISTPPLG6 NPs can act as potential drug carriers for the oral delivery of insulin.

  17. Novel PLGA-based nanoparticles for the oral delivery of insulin

    PubMed Central

    Malathi, Sampath; Nandhakumar, Perumal; Pandiyan, Velayudham; Webster, Thomas J; Balasubramanian, Sengottuvelan

    2015-01-01

    Background Insulin is the drug therapy for patients with insulin-dependent diabetes mellitus. A number of attempts have been made in the past to overcome the problems associated with the oral delivery of insulin, but with little success. Orally administered insulin has encountered with many difficulties such as rapid degradation and poor intestinal absorption. The potential use of D-α-tocopherol poly(ethylene glycol) 1000 succinate (TPGS)-emulsified poly(ethylene glycol) (PEG)-capped poly(lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) was investigated for sustained delivery of insulin (IS). Objective To investigate the efficacy of TPGS-emulsified PEG-capped PLGA NPs (TPPLG NPs) as a potential drug carrier for the oral delivery of insulin. Methods A series of biodegradable low-molecular-weight PLGA (80/20 [PLG4] and 70/30 [PLG6]) copolymers were synthesized by melt polycondensation. The commercial insulin-loaded TPGS-emulsified PEG-capped PLGA NPs (ISTPPLG NPs) were synthesized by water–oil–water emulsion solvent evaporation method. The physical and chemical properties of PLGA copolymers, particle size, zeta potential, and morphology of the NPs were examined. The in vivo studies of ISTPPLG NPs were carried out in diabetic rats by oral administration. Results The maximum encapsulation efficiency of ISTPPLG6 NPs was 78.6%±1.2%, and the mean diameter of the NPs was 180±20 nm. The serum glucose level was significantly (twofold) decreased on treatment with ISTPPLG NPs, and there was a threefold decrease with insulin-loaded PLGA (70/30) NPs when compared to that of free insulin-treated diabetic rats. The results show that the oral administration of ISTPPLG6 NPs is an effective method of reducing serum glucose level for a period of 24 hours. Histopathological studies reveal that ISTPPLG NPs could restore the damage caused by streptozotocin in the liver, kidneys, and pancreas, indicating its biocompatibility and regenerative effects. Conclusion ISTPPLG6 NPs can act as potential drug carriers for the oral delivery of insulin. PMID:25848248

  18. Oral Insulin Delivery in a Physiologic Context: Review

    PubMed Central

    Arbit, Ehud; Kidron, Miriam

    2017-01-01

    Insulin remains indispensable to the treatment of diabetes, but its availability in injectable form only has hampered its timely and broader use. The development of an oral insulin remains an ultimate goal to both enhance ease of use, and to provide therapeutic advantages rooted in its direct delivery to the portal vein and liver. By mimicking the physiological path taken by pancreatic insulin, oral insulin is expected to have a distinct effect on the hepatic aspect of carbohydrate metabolism, hepatic insulin resistance, and, at the same time, avoid hyperinsulinemia and minimize the risk of hypoglycemia. With oral insulin approaching late stages of development, the goal of this review is to examine oral insulin in a physiological context and report on recent progress in its development. PMID:28654313

  19. Future therapeutic directions; new medications and insulin delivery in a changing world for effective diabetes management.

    PubMed

    Modi, Pankaj

    2009-09-01

    Insulin remains a key to the management of diabetes. The early addition of insulin to oral therapy in type-2 patients is recognized as an effective option that can help improve glycemic control and reduces the complications and contribute to more favorable outcomes. Controlling blood glucose levels within acceptable limits is crucial to the long-term health of patients with diabetes. The benefits of patient education and chronic disease management tools cannot be underestimated as many patients will require education and help in initiation of insulin therapy to achieve glycemic targets. The wide choice of insulin formulations and the ever-expanding range of delivery methods are now available. These methods made insulin administration easier, less painful, more discreet, and more accurate than ever before thus providing important tools to overcome barriers to insulin initiation and improve achievement of glycemic goals. In addition, exciting developments in newer therapeutics have increased the potential for optimal glycemic control. This review discusses how these approaches can help patients manage their diabetes effectively by considering new insulin formulations and delivery devices and newer therapeutics.

  20. Noninvasive Ultrasound Transdermal Insulin Delivery and Glucose Monitoring Using a Low-Profile Cymbal Array

    NASA Astrophysics Data System (ADS)

    Park, E.-J.; Luis, J.; Meyer, R. J.; Pishko, M. V.; Smith, N. B.

    2006-05-01

    Recent studies have shown that ultrasound mediated transdermal drug delivery offers promising results for noninvasive drug administration. The purpose of this study was to demonstrate ultrasonic transdermal insulin delivery and in vivo sensing glucose with a novel, low-profile ultrasound array based on the cymbal transducer. As a practical device, the array composed of circular cymbal transducers was thin (< 7mm) and weighed less than 22g. Using this array on hyperglycemic rats, our previous experiments demonstrated that blood glucose would decrease by 296.7 mg/dL from 60 minutes of ultrasound exposure. With a similar intensity, our goal was to evaluate the feasibility of insulin delivery with large animals (rabbits and pigs) and noninvasively determine the glucose level of hyperglycemic rats with the array system. Ultrasound was exposed for 60 minutes at Isptp=100 mW/cm2. With the same procedure, a preliminary experiment of large animal was performed on a pig (12 kg) at Isptp=50 mW/cm2. For the control experiments in insulin delivery, the blood glucose level varied little from the initial baseline. However, for the ultrasound and insulin exposure experiment, the glucose level was found to decrease by 132.6 mg/dL in 60 minutes and continued to decrease by 208.1 mg/dL in 90 minutes. From the preliminary pig experiment, the blood glucose level decreased by 120 mg/dL in 90 minutes. To noninvasively determine the glucose level, ultrasound exposure experiments with an electrochemical glucose biosensor were performed on hyperglycemic rats. After 20 minutes ultrasound exposure, the biosensor was placed at the exposure area to determine the concentration of glucose diffused through the skin. The glucose level of rats determined by the biosensor was 408 mg/dL which was very similar to the results of conventional glucose meter reading 396.7 mg/dL. Recently, a rectangular cymbal transducer was developed to obtain a larger sonication area without an increase in array size. Preliminary experiments were performed on hyperglycemic rabbits to evaluate the new transducer design. The results showed that the rectangular array has enhanced performance compared to the circular array. All results of ultrasound application indicate the feasibility of using a low-cost, light-weight cymbal array for enhanced noninvasive transdermal insulin delivery and glucose monitoring.

  1. pH responsive cylindrical MSN for oral delivery of insulin-design, fabrication and evaluation.

    PubMed

    Guha, Arijit; Biswas, Nikhil; Bhattacharjee, Kaustav; Sahoo, Nityananda; Kuotsu, Ketousetuo

    2016-11-01

    The objective of the present study was to develop novel PMV [poly (methacrylic acid-co-vinyl triethoxylsilane)]-coated mesoporous silica nanoparticles (MSN) with improved hypoglycemic effect for oral insulin (INS) delivery. MSN was synthesized under acidic condition using Pluronic® P 123 and Tetra ethoxy orthosilane. Surfactant was removed by calcination. Calcined MSN was coated with pH sensitive polymer PMV. Cytotoxicity of this coated MSN was evaluated by MTT assay using CHO-K1 cell line. Different MSN samples were characterized with BET surface area analyzer, FESEM, TEM, FT-IR, XRD, TG-DTA. In vivo study was performed using male rats. Pharmacokinetic study was conducted using HPLC. Highest surface area (304.3921 m 2 /g) was observed in case of calcined sample. Adsorption pore width of final coated sample was highest (64.7844 nm) compared with others. No noticeable cytotoxicity was observed for this coated support. The entrapment efficiency of insulin was found to be 39.39%. In vitro studies were done at different pH using Franz-diffusion cell. Results showed significant release at pH 7.4. Cumulative drug release over a period of 6 h was more than 48% at this systemic pH. Effect of this MSN-PMV-INS on blood glucose level was retained for 16 h. This novel formulation has shown 73.10% relative bioavailability of insulin. A novel-coated mesoporous silica support was successfully developed for delivery of insulin through oral route.

  2. Influence of deposition and spray pattern of nasal powders on insulin bioavailability.

    PubMed

    Pringels, E; Callens, C; Vervaet, C; Dumont, F; Slegers, G; Foreman, P; Remon, J P

    2006-03-09

    The influence of the deposition pattern and spray characteristics of nasal powder formulations on the insulin bioavailability was investigated in rabbits. The formulations were prepared by freeze drying a dispersion containing a physical mixture of drum dried waxy maize starch (DDWM)/Carbopol 974P (90/10, w/w) or a spray-dried mixture of Amioca starch/Carbopol 974P (25/75, w/w). The deposition in the nasal cavity of rabbits and in a silicone human nose model after actuation of three nasal delivery devices (Monopowder, Pfeiffer and experimental system) was compared and related to the insulin bioavailability. Posterior deposition of the powder formulation in the nasal cavity lowered the insulin bioavailability. To study the spray pattern, the shape and cross-section of the emitted powder cloud were analysed. It was concluded that the powder bulk density of the formulation influenced the spray pattern. Consequently, powders of different bulk density were prepared by changing the solid fraction of the freeze dried dispersion and by changing the freezing rate during freeze drying. After nasal delivery of these powder formulations no influence of the powder bulk density and of the spray pattern on the insulin bioavailability was observed.

  3. [From insulin pump and continuous glucose monitoring to the artificial pancreas].

    PubMed

    Apablaza, Pamela; Soto, Néstor; Codner, Ethel

    2017-05-01

    Technology for diabetes care has undergone major development during recent decades. These technological advances include continuous subcutaneous insulin infusion (CSII), also known as insulin pumps, and real-time continuous glucose monitoring system (RT-CGMS). The integration of CSII and RT-CGMS into a single device has led to sensor-augmented pump therapy and more recently, a technology that has automated delivery of basal insulin therapy, known as hybrid system. These new technologies have led to benefits in attaining better metabolic control and decreasing the incidence of severe hypoglycemia, especially in patients with type 1 diabetes. This review describes the types of technologies currently available or under investigation for these purposes, their benefits and disadvantages, recommendations and the appropriate patient selection for their use. The clinical use of the hybrid system and artificial pancreas seem to be possible in the near future.

  4. Variability of Insulin Requirements Over 12 Weeks of Closed-Loop Insulin Delivery in Adults With Type 1 Diabetes.

    PubMed

    Ruan, Yue; Thabit, Hood; Leelarathna, Lalantha; Hartnell, Sara; Willinska, Malgorzata E; Dellweg, Sibylle; Benesch, Carsten; Mader, Julia K; Holzer, Manuel; Kojzar, Harald; Evans, Mark L; Pieber, Thomas R; Arnolds, Sabine; Hovorka, Roman

    2016-05-01

    To quantify variability of insulin requirements during closed-loop insulin delivery. We retrospectively analyzed overnight, daytime, and total daily insulin amounts delivered during a multicenter closed-loop trial involving 32 adults with type 1 diabetes. Participants applied hybrid day-and-night closed-loop insulin delivery under free-living home conditions over 12 weeks. The coefficient of variation was adopted to measure variability of insulin requirements in individual subjects. Data were analyzed from 1,918 nights, 1,883 daytime periods and 1,564 total days characterized by closed-loop use over 85% of time. Variability of overnight insulin requirements (mean [SD] coefficient of variation 31% [4]) was nearly twice as high as variability of total daily requirements (17% [3], P < 0.001) and was also higher than variability of daytime insulin requirements (22% [4], P < 0.001). Overnight insulin requirements were significantly more variable than daytime and total daily amounts. This may explain why some people with type 1 diabetes report frustrating variability in morning glycemia. © 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  5. Insulin pump use compared with intravenous insulin during labour and delivery: the INSPIRED observational cohort study.

    PubMed

    Drever, E; Tomlinson, G; Bai, A D; Feig, D S

    2016-09-01

    To assess the safety and efficacy of pump therapy (continuous subcutaneous insulin infusion; CSII) during labour and delivery in women with Type 1 diabetes. A retrospective cohort study of 161 consecutive Type 1 diabetic pregnancies delivered during 2000-2010 at Mount Sinai Hospital, Toronto, Canada. Capillary blood glucose levels during labour and delivery and time in/out of target (target: 4-6 mmol/l) were compared along with neonatal outcomes for three groups: (1) women on pumps who stayed on pumps during labour (pump/pump n = 31), (2) women on pumps who switched to intravenous (IV) insulin infusion during labour (pump/IVn = 25), and (3) women on multiple daily injections who switched to IV insulin infusion during labour (MDIn = 105). There were no significant differences between the mean or median glucose values during labour and delivery across all three groups, and no significant difference in time spent hypoglycaemic. However, women in the pump/pump group had significantly better glycaemic control as defined by mean glucose (5.5 vs. 6.4 mmol/l; P = 0.01), median glucose (5.4 vs. 6.3 mmol/l; P = 0.02), and more time spent in target (60.9% vs. 39.2%; P = 0.06) compared with women in the pump/IV group (after removing one outlier). This study demonstrates that the continuation of CSII therapy during labour and delivery appears safe and efficacious. Moreover, women who choose to continue CSII have better glucose control during delivery than those who switch to IV insulin, suggesting that it should be standard practice to allow women the option of continuing CSII during labour and delivery. © 2016 Diabetes UK.

  6. A Journey to Improved Inpatient Glycemic Control by Redesigning Meal Delivery and Insulin Administration.

    PubMed

    Engle, Martha; Ferguson, Allison; Fields, Willa

    2016-01-01

    The purpose of this quality improvement project was to redesign a hospital meal delivery process in order to shorten the time between blood glucose monitoring and corresponding insulin administration and improve glycemic control. This process change redesigned the workflow of the dietary and nursing departments. Modifications included nursing, rather than dietary, delivering meal trays to patients receiving insulin. Dietary marked the appropriate meal trays and phoned each unit prior to arrival on the unit. The process change was trialed on 2 acute care units prior to implementation hospital wide. Elapsed time between blood glucose monitoring and insulin administration was analyzed before and after process change as well as evaluation of glucometrics: percentage of patients with blood glucose between 70 and 180 mg/dL (percent perfect), blood glucose greater than 300 mg/dL (extreme hyperglycemia), and blood glucose less than 70 mg/dL (hypoglycemia). Percent perfect glucose results improved from 45% to 53%, extreme hyperglycemia (blood glucose >300 mg/dL) fell from 11.7% to 5%. Hypoglycemia demonstrated a downward trend line, demonstrating that with improving glycemic control hypoglycemia rates did not increase. Percentage of patients receiving meal insulin within 30 minutes of blood glucose check increased from 35% to 73%. In the hospital, numerous obstacles were present that interfered with on-time meal insulin delivery. Establishing a meal delivery process with the nurse performing the premeal blood glucose check, delivering the meal, and administering the insulin improves overall blood glucose control. Nurse-led process improvement of blood glucose monitoring, meal tray delivery, and insulin administration does lead to improved glycemic control for the inpatient population.

  7. Antidiabetic Activity of Self Nanoemulsifying Drug Delivery System from Bay Leaves (Eugenia polyantha Wight) Ethyl Acetate Fraction

    NASA Astrophysics Data System (ADS)

    Prihapsara, F.; Harini, M.; Widiyani, T.; Artanti, A. N.; Ani, I. L.

    2017-02-01

    Insulin resistance is caused by inability of target tissues to insulin response. Bay leaves (Eugenia polyantha Wight) fraction or extract have been used for the treatment of antidibetic mellitus type-2 resistance insulin (ADMRI) but it has low solubility and bioavailability. To overcome these problems, ethyl acetate fraction of bay leaves was formulated into self nanoemulsifying drug delivery system (SNEDDS) using Virgin Coconut Oil (VCO) as a carrier oil. This study aims to produce nanoherbal medicine, determine effect of nanoherbal preparation derived from bay leaves as an anti-ADMRI. The results showed that the optimum SNEDDS formula was tween 80 : PEG 400 : Virgin Coconut Oil (30% : 60% : 10%) in 5 mL. It has emulsification time 13.00 seconds with the average of droplet size value 84.5 nanometer and zeta potential value ± 0.2 mV. Morphological observation showed the nanoemulsion particles has spherical shaped and stable in different pH media. Hypoglycaemic effect of single dose metformin, SNEDDS, combination a-half dose of SNEEDS with metformin value is 28.3%; 15.6%; 34.6% respectively.

  8. Endothelial Fcγ Receptor IIB Activation Blunts Insulin Delivery to Skeletal Muscle to Cause Insulin Resistance in Mice

    PubMed Central

    Tanigaki, Keiji; Chambliss, Ken L.; Yuhanna, Ivan S.; Sacharidou, Anastasia; Ahmed, Mohamed; Atochin, Dmitriy N.; Huang, Paul L.

    2016-01-01

    Modest elevations in C-reactive protein (CRP) are associated with type 2 diabetes. We previously revealed in mice that increased CRP causes insulin resistance and mice globally deficient in the CRP receptor Fcγ receptor IIB (FcγRIIB) were protected from the disorder. FcγRIIB is expressed in numerous cell types including endothelium and B lymphocytes. Here we investigated how endothelial FcγRIIB influences glucose homeostasis, using mice with elevated CRP expressing or lacking endothelial FcγRIIB. Whereas increased CRP caused insulin resistance in mice expressing endothelial FcγRIIB, mice deficient in the endothelial receptor were protected. The insulin resistance with endothelial FcγRIIB activation was due to impaired skeletal muscle glucose uptake caused by attenuated insulin delivery, and it was associated with blunted endothelial nitric oxide synthase (eNOS) activation in skeletal muscle. In culture, CRP suppressed endothelial cell insulin transcytosis via FcγRIIB activation and eNOS antagonism. Furthermore, in knock-in mice harboring constitutively active eNOS, elevated CRP did not invoke insulin resistance. Collectively these findings reveal that by inhibiting eNOS, endothelial FcγRIIB activation by CRP blunts insulin delivery to skeletal muscle to cause insulin resistance. Thus, a series of mechanisms in endothelium that impairs insulin movement has been identified that may contribute to type 2 diabetes pathogenesis. PMID:27207525

  9. Polymer microneedles fabricated from alginate and hyaluronate for transdermal delivery of insulin.

    PubMed

    Yu, Weijiang; Jiang, Guohua; Zhang, Yang; Liu, Depeng; Xu, Bin; Zhou, Junyi

    2017-11-01

    To reduce the inconvenient and painful of subcutaneous needle injection, the polymer microneedle patches that fabricated from modified alginate and hyaluronate were prepared for transdermal delivery of insulin. The as-prepared microneedles (MNs) exhibited excellent mechanical strength to penetrate the skin and good degradability to release loaded insulin. In vitro skin insertion capability was determined by staining with tissue-marking dye after insertion, and the real-time penetration depth was monitored using optical coherence tomography. Confocal microscopy images revealed that the rhodamine B and fluorescein isothiocyanate-labeled insulin (FITC-insulin) can gradually diffuse from the puncture sites to deeper tissue. In vivo and pharmacodynamic studies were then conducted to estimate the feasibility of the administration of insulin-loaded microneedle patches on diabetic mice for glucose regulation. The relative pharmacologic availability (RPA) and relative bioavailability (RBA) of insulin from microneedle patches were 90.5±6.8% and 92.9±7%, respectively. These results suggests the MNs developed in this study have a promising application in diabetes treatment via transdermal delivery. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Potential of insulin nanoparticle formulations for oral delivery and diabetes treatment.

    PubMed

    Wong, Chun Y; Al-Salami, Hani; Dass, Crispin R

    2017-10-28

    Nanoparticles have demonstrated significant advancements in potential oral delivery of insulin. In this publication, we review the current status of polymeric, inorganic and solid-lipid nanoparticles designed for oral administration of insulin. Firstly, the structure and physiological function of insulin are examined. Then, the efficiency and shortcomings of insulin nanoparticle are discussed. These include the susceptibility to digestive enzyme degradation, instability in the acidic pH environment, poor mucus diffusion and inadequate permeation through the gastrointestinal epithelium. In order to optimise the nanocarriers, the following considerations, including polymer nature, surface charge, size, polydispersity index and morphology of nanoparticles, have to be taken into account. Some novel designs such as chitosan-based glucose-responsive nanoparticles, layer by layer technique-based nanoparticles and zwitterion nanoparticles are being adopted to overcome the physiological challenges. The review ends with some future directions and challenges to be addressed for the success of oral delivery of insulin-loaded nanoparticle formulation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Pure Insulin Nanoparticle Agglomerates for Pulmonary Delivery

    PubMed Central

    Bailey, Mark M.; Gorman, Eric M.; Munson, Eric J.; Berkland, Cory J.

    2009-01-01

    Diabetes is a set of diseases characterized by defects in insulin utilization, either through autoimmune destruction of insulin-producing cells (Type I) or insulin resistance (Type II). Treatment options can include regular injections of insulin, which can be painful and inconvenient, often leading to low patient compliance. To overcome this problem, novel formulations of insulin are being investigated, such as inhaled aerosols. Sufficient deposition of powder in the peripheral lung to maximize systemic absorption requires precise control over particle size and density, with particles between 1 and 5 μm in aerodynamic diameter being within the respirable range. Insulin nanoparticles were produced by titrating insulin dissolved at low pH up to the pI of the native protein, and were then further processed into microparticles using solvent displacement. Particle size, crystallinity, dissolution properties, structural stability, and bulk powder density were characterized. We have demonstrated that pure drug insulin microparticles can be produced from nanosuspensions with minimal processing steps without excipients, and with suitable properties for deposition in the peripheral lung. PMID:18959432

  12. Portosystemic shunt as a cause of congenital hyperinsulinemic hypoglycemia.

    PubMed

    Yoshii, Keisuke; Noda, Masahiro; Naiki, Yasuhiro; Horikawa, Reiko

    2017-04-01

    Congenital hyperinsulinemic hypoglycemia (CHH) is characterized by the inappropriate secretion of insulin from pancreatic beta cells in the presence of hypoglycemia. We herein describe the case of a 5-month-old boy with CHH due to congenital portosystemic shunt (CPSS). Insulin secreted from pancreatic beta cells flows into the portal vein and is first metabolized in the liver. First-pass elimination of insulin in the liver leads to great decrease in insulin concentration by approximately 40-80% in humans. CPSS accounts for a large quantity of insulin delivery into the systemic circulation due to the lack of hepatic first-pass elimination. Hypoglycemia can result from consistently high levels of insulin after reaching normal glucose level. CPSS therefore should be considered as a rare cause of CHH, especially in the case of post-prandial hyperinsulinemic hypoglycemia. © 2017 Japan Pediatric Society.

  13. Oral insulin delivery, the challenge to increase insulin bioavailability: Influence of surface charge in nanoparticle system.

    PubMed

    Czuba, Elodie; Diop, Mouhamadou; Mura, Carole; Schaschkow, Anais; Langlois, Allan; Bietiger, William; Neidl, Romain; Virciglio, Aurélien; Auberval, Nathalie; Julien-David, Diane; Maillard, Elisa; Frere, Yves; Marchioni, Eric; Pinget, Michel; Sigrist, Séverine

    2018-05-05

    Oral administration of insulin increases patient comfort and could improve glycemic control thanks to the hepatic first passage. However, challenges remain. The current approach uses poly (d, lactic-co-glycolic) acid (PLGA) nanoparticles (NPs), an effective drug carrier system with a long acting profile. However, this system presents a bioavailability of less than 20% for insulin encapsulation. In this context, physico-chemical parameters like surface charge could play a critical role in NP uptake by the intestinal barrier. Therefore, we developed a simple method to modulate NP surface charge to test its impact on uptake in vitro and finally on NP efficiency in vivo. Various NPs were prepared in the presence (+) or absence (-) of polyvinyl alcohol (PVA), sodium dodecyl sulfate (SDS), and/or coated with chitosan chloride. In vitro internalization was tested using epithelial culture of Caco-2 or using a co-culture (Caco-2/RevHT29MTX) by flow cytometry. NPs were then administered by oral route using a pharmaceutical complex vector (100 or 250 UI/kg) in a diabetic rat model. SDS-NPs (-42 ± 2 mV) were more negatively charged than -PVA-NPs (-22 ± 1 mV) and chitosan-coated NPs were highly positively charged (56 ± 2 mV) compared to +PVA particles (-2 ± 1 mV), which were uncharged. In the Caco-2 model, NP internalization was significantly improved by using negatively charged NPs (SDS NPs) compared to using classical NPs (+PVA NPs) and chitosan-coated NPs. Finally, the efficacy of insulin SDS-NPs was demonstrated in vivo (100 or 250 UI insulin/kg) with a reduction of blood glucose levels in diabetic rats. Formulation of negatively charged NPs represents a promising approach to improve NP uptake and insulin bioavailability for oral delivery. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Modular reservoir concept for MEMS-based transdermal drug delivery systems

    NASA Astrophysics Data System (ADS)

    Cantwell, Cara T.; Wei, Pinghung; Ziaie, Babak; Rao, Masaru P.

    2014-11-01

    While MEMS-based transdermal drug delivery device development efforts have typically focused on tightly-integrated solutions, we propose an alternate conception based upon a novel, modular drug reservoir approach. By decoupling the drug storage functionality from the rest of the delivery system, this approach seeks to minimize cold chain storage volume, enhance compatibility with conventional pharmaceutical practices, and allow independent optimization of reservoir device design, materials, and fabrication. Herein, we report the design, fabrication, and preliminary characterization of modular reservoirs that demonstrate the virtue of this approach within the application context of transdermal insulin administration for diabetes management.

  15. Omentin, an adipokine with insulin-sensitizing properties, is negatively associated with insulin resistance in normal gestation.

    PubMed

    Brandt, Benny; Mazaki-Tovi, Shali; Hemi, Rina; Yinon, Yoav; Schiff, Eyal; Mashiach, Roy; Kanety, Hannah; Sivan, Eyal

    2015-05-01

    Omentin, a newly identified adipokine, enhances insulin mediated glucose uptake in human adipocytes, thus, inducing systemic insulin-sensitizing effect. The aims of this study were to determine whether circulating maternal omentin levels are associated with insulin resistance indices and to assess which compartment, maternal, fetal, or placental, is the source of omentin in maternal circulation. Fasting serum glucose, insulin, and omentin were determined in 25 healthy pregnant women at the third trimester, before and 3 days after elective cesarean section. Cord blood omentin was measured in the 25 term neonates. Homeostasis model assessment (HOMA) was used to evaluate insulin sensitivity before and after delivery. Antepartum maternal omentin levels were negatively correlated with insulin levels (r=-0.41, P=0.04) and positively correlated with insulin sensitivity (HOMA%S; r=0.4, P=0.04). Postpartum omentin levels were negatively correlated with maternal body mass index (r=-0.44, P=0.02). Median maternal omentin levels was comparable before and after delivery (57.2, inter-quartile range: 38.2-76.2 ng/mL vs. 53.4, 39.8-69.4 ng/mL, respectively, P=0.25) and highly correlated (r=0.83, P<0.001). Antepartum maternal and neonatal omentin levels did not differ significantly (fetal: 62.2, 44.3-74.2 ng/mL, P=0.77) and did not correlate (P=0.6). Circulating maternal omentin levels are correlated with insulin resistance indices, suggesting that this adipokine may play a role in metabolic adaptations of normal gestation. The strong correlation between anteparum and postpartum maternal omentin levels, as well as the lack of association between maternal and neonatal omentin levels, suggest that placental or fetal compartments are unlikely as the main source of circulating maternal omentin.

  16. The Use of Low Molecular Weight Protamine Chemical Chimera to Enhance Monomeric Insulin Intestinal Absorption

    PubMed Central

    He, Huining; Sheng, Jianyong; David, Allan E.; Kwon, Young Min; Zhang, Jian; Huang, Yongzhuo; Wang, Jianxin; Yang, Victor C.

    2013-01-01

    Although oral delivery of insulin offers a number of unmatched advantages, it nevertheless is beset by the poor permeability of insulin molecules through the epithelial cell membranes of the intestinal mucosal layer. We previously reported the development of low molecular weight protamine (LMWP) as a nontoxic yet potent cell penetrating peptide, of which via covalent linkage was capable of translocating protein cargos through the membranes of almost all cell types. It is therefore hypothesized that LMWP could be practically employed as a safe and effective tool to deliver insulin across the intestinal mucosal membrane, thereby augmenting its absorption through the GI tract. However, formulating 1:1 monomeric insulin/LMWP conjugate presents a tall order of challenge, as the acidic insulin and basic LMWP would automatically form tight aggregates through electrostatic interactions. In this paper, we developed an innovative conjugation strategy to solve this problem, by using succinimidyl-[(N-maleimidopropionamido)-polyethyleneglycol] ester (NHS-PEG-MAL) as an intermediate cross-linker during the coupling process. Both SDS-PAGE and MALDI-TOF mass spectroscopy confirmed the formation of a homogeneous, monomeric (1:1 ratio) insulin/LMWP conjugate without encountering the conventional problem of substrate aggregation. Cell culture studies demonstrated that transport of the Insulin-PEG-LMWP conjugate across the intestinal mucosal monolayer was augmented by almost five folds compared to native insulin. Furthermore, results from the in situ loop absorption tests in rats showed that systemic pharmacological bioavailability of insulin was significantly enhanced after its conjugation with LMWP. Overall, the presented chemical conjugation with LMWP could offer a reliable and safe means to improve the intestinal permeability of therapeutic peptides/proteins, shedding light of the possibility for their effective oral delivery. PMID:23863452

  17. Glucose-Responsive Implantable Polymeric Microdevices for "Smart" Insulin Therapy of Diabetes

    NASA Astrophysics Data System (ADS)

    Chu, Michael Kok Loon

    Diabetes mellitus is a chronic illness manifested by improper blood glucose management, affecting over 350 million worldwide. As a result, all type 1 patients and roughly 20% of type 2 patients require exogenous insulin therapy to survive. Typically, daily multiple injections are taken to maintain normal glucose levels in response glucose spikes from meals. However, patient compliance and dosing accuracy can fluctuate with variation in meals, exercise, glucose metabolism or stress, leading to poor clinical outcomes. A 'smart', closed-loop insulin delivery system providing on-demand release kinetics responding to circulating glucose levels would be a boon for diabetes patients, replacing constant self monitoring and insulin. This thesis focuses on the development of a novel, 'smart' insulin microdevice that can provide on-demand insulin release in response to blood glucose levels. In the early stage, the feasibility of integrating a composite membrane with pH-responsive nanoparticles embedded in ethylcellulose membrane to provide pH-responsive in vitro release was examined and confirmed using a model drug, vitamin B12. In the second microdevice, glucose oxidase for generating pH signals from glucose oxidation, catalase and manganese dioxide nanoparticles, as peroxide scavengers, were used in a bioinorganic, albumin-based membrane cross-linked with a polydimethylsiloxane (PDMS) grid-microdevice system. This prototype device demonstrated insulin release in response to glucose levels in vitro and regulating plasma glucose in type 1 diabetic rats when implanted intraperitoneally. Advancement allowing for subcutaneous implantation and improved biocompatibility was achieved with surface modification of PDMS microdevices grafted with activated 20 kDa polyethylene glycol (PEG) chains, dramatically reducing immune response and local inflammation. When implanted subcutaneously in diabetic rats, glucose-responsive insulin delivery microdevices showed short and long-term efficacy up to an 18 day period. Finally, to improve insulin stability within microdevice reservoirs, an in situ gelling zinc-insulin formulation was designed. High concentration insulin gel complexed with zinc provided physical and chemical stability against thermal denaturation over a 30 day period. Long-term stability of the zinc-insulin gel formulation shows potential for sustained release application, providing low-level, basal insulin release. These combined technologies present significant progress towards the goal of an 'artificial pancreas' to combat diabetes through 'smart' insulin therapy.

  18. Development and evaluation of mucoadhesive nanoparticles based on thiolated Eudragit for oral delivery of protein drugs

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Yang, Zhijie; Hu, Xi; Zhang, Ling; Li, Feng; Li, Meimei; Tang, Xing; Xiao, Wei

    2015-02-01

    The objective of this study was to develop pH-sensitive Eudragit L100-cysteine/reduced glutathione (Eul-cys/GSH) nanoparticles (NPs), which provided the mucoadhesion and protection for protein drugs against enzymatic degradation. Insulin was chosen as a model biomolecule for testing this system. The Eul-cys conjugate, which was obtained by grafting cysteine onto the carboxy group of Eudragit L100, was analyzed by HNMR and SEM, and the swelling degree (SD), cation binding, and enzymatic inhibition were also determined. The results obtained showed that the Eul-cys conjugate represent a pH-sensitive delivery system which effectively protected the insulin from being degraded by the proteases, and this is related to the mechanism of Ca2+ binding. Insulin-loaded Eul-cys/GSH NPs were prepared by a diffusion method involving an electrostatic interaction between the network structure of the polymer and the embedded proteins, including insulin and GSH. TEM images indicated that Eul-cys/GSH existed as smooth and spherical NPs in aqueous solution with particle sizes of 260 ± 20 nm. The X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) findings showed the presence of amorphous insulin in thiolated NPs and higher free thiol oxidation than the result obtained by Ellman's reagent method. In addition, thiolated NPs showed excellent binding efficiency to the mucin in rat intestine, indicating that Eul-cys/GSH NPs have great potential to be applied as safe carriers for the oral administration of protein drugs.

  19. How can insulin initiation delivery in a dual-sector health system be optimised? A qualitative study on healthcare professionals' views.

    PubMed

    Lee, Ping Yein; Lee, Yew Kong; Ng, Chirk Jenn

    2012-04-30

    The prevalence of type 2 diabetes is increasing at an alarming rate in developing countries. However, glycaemia control remains suboptimal and insulin use is low. One important barrier is the lack of an efficient and effective insulin initiation delivery approach. This study aimed to document the strategies used and proposed by healthcare professionals to improve insulin initiation in the Malaysian dual-sector (public-private) health system. In depth interviews and focus group discussions were conducted in Klang Valley and Seremban, Malaysia in 2010-11. Healthcare professionals consisting of general practitioners (n = 11), medical officers (n = 8), diabetes educators (n = 3), government policy makers (n = 4), family medicine specialists (n = 10) and endocrinologists (n = 2) were interviewed. We used a topic guide to facilitate the interviews, which were audio recorded, transcribed verbatim and analysed using a thematic approach. Three main themes emerged from the interviews. Firstly, there was a lack of collaboration between the private and public sectors in diabetes care. The general practitioners in the private sector proposed an integrated system for them to refer patients to the public health services for insulin initiation programmes. There could be shared care between the two sectors and this would reduce the disproportionately heavy workload at the public sector. Secondly, besides the support from the government health authority, the healthcare professionals wanted greater involvement of non-government organisations, media and pharmaceutical industry in facilitating insulin initiation in both the public and private sectors. The support included: training of healthcare professionals; developing and disseminating patient education materials; service provision by diabetes education teams; organising programmes for patients' peer group sessions; increasing awareness and demystifying insulin via public campaigns; and subsidising glucose monitoring equipment. Finally, the healthcare professionals proposed the establishment of multidisciplinary teams as a strategy to increase the rate of insulin initiation. Having team members from different ethnic backgrounds would help to overcome language and cultural differences when communicating with patients. The challenges faced by a dual-sector health system in delivering insulin initiation may be addressed by greater collaborations between the private and public sectors and governmental and non-government organisations, and among different healthcare professionals.

  20. How can insulin initiation delivery in a dual-sector health system be optimised? A qualitative study on healthcare professionals’ views

    PubMed Central

    2012-01-01

    Background The prevalence of type 2 diabetes is increasing at an alarming rate in developing countries. However, glycaemia control remains suboptimal and insulin use is low. One important barrier is the lack of an efficient and effective insulin initiation delivery approach. This study aimed to document the strategies used and proposed by healthcare professionals to improve insulin initiation in the Malaysian dual-sector (public–private) health system. Methods In depth interviews and focus group discussions were conducted in Klang Valley and Seremban, Malaysia in 2010–11. Healthcare professionals consisting of general practitioners (n = 11), medical officers (n = 8), diabetes educators (n = 3), government policy makers (n = 4), family medicine specialists (n = 10) and endocrinologists (n = 2) were interviewed. We used a topic guide to facilitate the interviews, which were audio recorded, transcribed verbatim and analysed using a thematic approach. Results Three main themes emerged from the interviews. Firstly, there was a lack of collaboration between the private and public sectors in diabetes care. The general practitioners in the private sector proposed an integrated system for them to refer patients to the public health services for insulin initiation programmes. There could be shared care between the two sectors and this would reduce the disproportionately heavy workload at the public sector. Secondly, besides the support from the government health authority, the healthcare professionals wanted greater involvement of non-government organisations, media and pharmaceutical industry in facilitating insulin initiation in both the public and private sectors. The support included: training of healthcare professionals; developing and disseminating patient education materials; service provision by diabetes education teams; organising programmes for patients’ peer group sessions; increasing awareness and demystifying insulin via public campaigns; and subsidising glucose monitoring equipment. Finally, the healthcare professionals proposed the establishment of multidisciplinary teams as a strategy to increase the rate of insulin initiation. Having team members from different ethnic backgrounds would help to overcome language and cultural differences when communicating with patients. Conclusion The challenges faced by a dual-sector health system in delivering insulin initiation may be addressed by greater collaborations between the private and public sectors and governmental and non-government organisations, and among different healthcare professionals. PMID:22545648

  1. Automated control of an adaptive bi-hormonal, dual-sensor artificial pancreas and evaluation during inpatient studies

    PubMed Central

    Jacobs, Peter G.; El Youssef, Joseph; Castle, Jessica; Bakhtiani, Parkash; Branigan, Deborah; Breen, Matthew; Bauer, David; Preiser, Nicholas; Leonard, Gerald; Stonex, Tara; Preiser, Nicholas; Ward, W. Kenneth

    2014-01-01

    Automated control of blood glucose in patients with type 1 diabetes has not yet been fully implemented. The aim of this study was to design and clinically evaluate a system that integrates a control algorithm with off-the-shelf subcutaneous sensors and pumps to automate the delivery of the hormones glucagon and insulin in response to continuous glucose sensor measurements. The automated component of the system runs an adaptive proportional derivative control algorithm which determines hormone delivery rates based on the sensed glucose measurements and the meal announcements by the patient. We provide details about the system design and the control algorithm, which incorporates both a fading memory proportional derivative controller (FMPD) and an adaptive system for estimating changing sensitivity to insulin based on a glucoregulatory model of insulin action. For an inpatient study carried out in eight subjects using Dexcom SEVEN PLUS sensors, pre-study HbA1c averaged 7.6, which translates to an estimated average glucose of 171 mg/dL. In contrast, during use of the automated system, after initial stabilization, glucose averaged 145 mg/dL and subjects were kept within the euglycemic range (between 70 and 180 mg/dL) for 73.1% of the time, indicating improved glycemic control. A further study on five additional subjects in which we used a newer and more reliable glucose sensor (Dexcom G4 PLATINUM) and made improvements to the insulin and glucagon pump communication system resulted in elimination of hypoglycemic events. For this G4 study, the system was able to maintain subjects’ glucose levels within the near-euglycemic range for 71.6% of the study duration and the mean venous glucose level was 151 mg/dL. PMID:24835122

  2. SNARE proteins underpin insulin-regulated GLUT4 traffic.

    PubMed

    Bryant, Nia J; Gould, Gwyn W

    2011-06-01

    Delivery of the glucose transporter type 4 (GLUT4) from an intracellular location to the cell surface in response to insulin represents a specialized form of membrane traffic, known to be impaired in the disease states of insulin resistance and type 2 diabetes. Like all membrane trafficking events, this translocation of GLUT4 requires members of the SNARE family of proteins. Here, we discuss two SNARE complexes that have been implicated in insulin-regulated GLUT4 traffic: one regulating the final delivery of GLUT4 to the cell surface in response to insulin and the other controlling GLUT4's intracellular trafficking. © 2011 John Wiley & Sons A/S.

  3. Drug permeability and mucoadhesion properties of thiolated trimethyl chitosan nanoparticles in oral insulin delivery.

    PubMed

    Yin, Lichen; Ding, Jieying; He, Chunbai; Cui, Liming; Tang, Cui; Yin, Chunhua

    2009-10-01

    Trimethyl chitosan-cysteine conjugate (TMC-Cys) was synthesized in an attempt to combine the mucoadhesion and the permeation enhancing effects of TMC and thiolated polymers related to different mechanisms for oral absorption. TMC-Cys with various molecular weights (30, 200, and 500 kDa) and quaternization degrees (15 and 30%) was allowed to form polyelectrolyte nanoparticles with insulin through self-assembly, which demonstrated particle size of 100-200 nm, zeta potential of +12 to +18 mV, and high encapsulation efficiency. TMC-Cys/insulin nanoparticles (TMC-Cys NP) showed a 2.1-4.7-fold increase in mucoadhesion compared to TMC/insulin nanoparticles (TMC NP), which might be partly attributed to disulfide formation between TMC-Cys and mucin as evidenced by DSC measurement. Compared to insulin solution and TMC NP, TMC-Cys NP induced increased insulin transport through rat intestine by 3.3-11.7 and 1.7-2.6 folds, promoted Caco-2 cell internalization by 7.5-12.7 and 1.7-3.0 folds, and augmented uptake in Peyer's patches by 14.7-20.9 and 1.7-5.0 folds, respectively. Such results were further confirmed by in vivo experiment with the optimal TMC-Cys NP. Biocompatibility assessment revealed lack of toxicity of TMC-Cys NP. Therefore, self-assembled nanoparticles between TMC-Cys and protein drugs could be an effective and safe oral delivery system.

  4. Chitosan Nanofibers for Transbuccal Insulin Delivery

    PubMed Central

    Lancina, Michael G.; Shankar, Roopa Kanakatti; Yang, Hu

    2017-01-01

    Purpose In this work, we aimed at producing chitosan based nanofiber mats capable of delivering insulin via the buccal mucosa. Methods Chitosan was electrospun into nanofibers using poly (ethylene oxide) (PEO) as a carrier molecule in various feed ratios. The mechanical properties and degradation kinetics of the fibers were measured. Insulin release rates were determined in vitro using an ELISA assay. The bioactivity of released insulin was measured in terms of Akt activation in pre-adipocytes. Insulin permeation across the buccal mucosa was measured in an ex-vivo porcine transbuccal model. Results Fiber morphology, mechanical properties, and in vitro stability were dependent on PEO feed ratio. Lower PEO content blends produced smaller diameter fibers with significantly faster insulin release kinetics. Insulin showed no reduction in bioactivity due to electrospinning. Buccal permeation of insulin facilitated by high chitosan content blends was significantly higher than that of free insulin. Conclusions Taken together, our work demonstrates chitosan based nanofibers have the potential to serve as a transbuccal insulin delivery vehicle. PMID:28000386

  5. Implantation of programmable infusion pumps for insulin delivery in type I diabetic patients.

    PubMed

    Walter, H; Günther, A; Kronski, D; Flaschenträger, T; Mehnert, H

    1989-06-01

    Five type I diabetic patients were followed prospectively during treatment with continuous subcutaneous insulin infusion by externally worn pumps and during the first 12 months after implantation of a remote-controlled insulin infusion device (ID1, Siemens AG). Stabilized insulin (Hoe 21 GH, Hoechst AG) was infused intravenously in two and intraperitoneally in three patients. Total observation time was 47.2 patient-months after implantation. Two devices had to be explanted prematurely, one because of a technical failure after 101 days, one due to a skin necrosis over the implant after 236 days. HbA1, frequency of hypoglycemia, total insulin dose, and basal rate infusion did not change after implantation. There was a reduction in the insulin antibodies 6 months after start of intravenous or intraperitoneal insulin delivery. Fasting plasma free insulin levels could be normalized only by intraperitoneal insulin infusion. Although a technical and a surgical problem was observed, our data show the successful implantation and clinical use of programmable dosing devices and stabilized insulin.

  6. Management of Hypoglycemia in Children and Adolescents with Type 1 Diabetes Mellitus.

    PubMed

    McGill, Dayna E; Levitsky, Lynne L

    2016-09-01

    Hypoglycemia and fear of hypoglycemia limit appropriate glycemic control in many children and adolescents with type 1 diabetes. Traditional approaches to the prevention of hypoglycemia including patient education about modifiable risk factors for hypoglycemia (changes in insulin, diet, and exercise) and frequency of self glucose monitoring remain important for hypoglycemia prevention. Continuous glucose monitoring systems with or without a partial closed-loop control of insulin infusion have been very useful in the prevention of hypoglycemia. Oral carbohydrate and parenteral glucagon continue to be the mainstays of hypoglycemia treatment. In the future, we can look forward to regulatory approval of closed-loop insulin delivery and glucose monitoring systems to facilitate euglycemia, as well as glucagon administered by the intranasal route to treat hypoglycemia.

  7. Microencapsulation techniques to develop formulations of insulin for oral delivery: a review.

    PubMed

    Cárdenas-Bailón, Fernando; Osorio-Revilla, Guillermo; Gallardo-Velázquez, Tzayhrí

    2013-01-01

    Oral insulin delivery represents one of the most challenging goals for pharmaceutical industry. In general, it is accepted that oral administration of insulin would be more accepted by patients and insulin would be delivered in a more physiological way than the parenteral route. From all strategies to deliverer insulin orally, microencapsulation or nanoencapsulation of insulin are the most promising approaches because these techniques protect insulin from enzymatic degradation in stomach, show a good release profile at intestine pH values, maintain biological activity during formulation and enhance intestinal permeation at certain extent. From different microencapsulation techniques, it seems that complex coacervation, multiple emulsion and internal gelation are the most appropriate techniques to encapsulate insulin due to their relative ease of preparation. Besides that, the use of organic solvents is not required and can be scaled up at low cost; however, relative oral bioavailability still needs to be improved.

  8. Long-Term Efficacy and Safety of Insulin and Glucokinase Gene Therapy for Diabetes: 8-Year Follow-Up in Dogs.

    PubMed

    Jaén, Maria Luisa; Vilà, Laia; Elias, Ivet; Jimenez, Veronica; Rodó, Jordi; Maggioni, Luca; Ruiz-de Gopegui, Rafael; Garcia, Miguel; Muñoz, Sergio; Callejas, David; Ayuso, Eduard; Ferré, Tura; Grifoll, Iris; Andaluz, Anna; Ruberte, Jesus; Haurigot, Virginia; Bosch, Fatima

    2017-09-15

    Diabetes is a complex metabolic disease that exposes patients to the deleterious effects of hyperglycemia on various organs. Achievement of normoglycemia with exogenous insulin treatment requires the use of high doses of hormone, which increases the risk of life-threatening hypoglycemic episodes. We developed a gene therapy approach to control diabetic hyperglycemia based on co-expression of the insulin and glucokinase genes in skeletal muscle. Previous studies proved the feasibility of gene delivery to large diabetic animals with adeno-associated viral (AAV) vectors. Here, we report the long-term (∼8 years) follow-up after a single administration of therapeutic vectors to diabetic dogs. Successful, multi-year control of glycemia was achieved without the need of supplementation with exogenous insulin. Metabolic correction was demonstrated through normalization of serum levels of fructosamine, triglycerides, and cholesterol and remarkable improvement in the response to an oral glucose challenge. The persistence of vector genomes and therapeutic transgene expression years after vector delivery was documented in multiple samples from treated muscles, which showed normal morphology. Thus, this study demonstrates the long-term efficacy and safety of insulin and glucokinase gene transfer in large animals and especially the ability of the system to respond to the changes in metabolic needs as animals grow older.

  9. Intradermal microneedle delivery of insulin lispro achieves faster insulin absorption and insulin action than subcutaneous injection.

    PubMed

    Pettis, Ronald J; Ginsberg, Barry; Hirsch, Laurence; Sutter, Diane; Keith, Steven; McVey, Elaine; Harvey, Noel G; Hompesch, Marcus; Nosek, Leszek; Kapitza, Christoph; Heinemann, Lutz

    2011-04-01

    This study compared insulin lispro (IL) pharmacokinetics (PK) and pharmacodynamics (PD) delivered via microneedle intradermal (ID) injection with subcutaneous (SC) injection under euglycemic glucose clamp conditions. Ten healthy male volunteers were administered 10 international units (IU) of IL at 3 microneedle lengths (1.25, 1.50, or 1.75 mm) in a randomized, crossover fashion on Days 1-3 followed by a repetitive ID 1.5-mm microneedle dose (Day 4) and an SC dose (Day 5). Microneedle ID delivery resulted in more rapid absorption of IL, with decreased time to maximum insulin concentration (ID vs. SC: 36.0-46.4 vs. 64.3 min, P < 0.05) and higher fractional availability at early postinjection times. ID produced more rapid effects on glucose uptake with shorter times to maximal and early half-maximal glucose infusion rates (GIRs) (ID vs. SC: time to maximum GIR, 106-112 vs. 130 min, P < 0.05; early half-maximal GIR, 29-35 vs. 42 min), increased early GIR area under the curve (AUC), and faster offset of insulin action (shorter time to late half-maximal GIR: 271-287 vs. 309 min). Relative total insulin bioavailability (AUC to 360 min and AUC to infinite measurement) did not significantly differ between administration routes. ID PK/PD parameters showed some variation as a function of needle length. Delivery of ID IL was generally well tolerated, although transient, localized wheal formation and redness were observed at injection sites. Microneedle ID insulin lispro delivery enables more rapid onset and offset of metabolic effect than SC therapy and is safe and well tolerated; further study for insulin therapy is warranted.

  10. Implantable batteryless device for on-demand and pulsatile insulin administration

    NASA Astrophysics Data System (ADS)

    Lee, Seung Ho; Lee, Young Bin; Kim, Byung Hwi; Lee, Cheol; Cho, Young Min; Kim, Se-Na; Park, Chun Gwon; Cho, Yong-Chan; Choy, Young Bin

    2017-04-01

    Many implantable systems have been designed for long-term, pulsatile delivery of insulin, but the lifetime of these devices is limited by the need for battery replacement and consequent replacement surgery. Here we propose a batteryless, fully implantable insulin pump that can be actuated by a magnetic field. The pump is prepared by simple-assembly of magnets and constituent units and comprises a drug reservoir and actuator equipped with a plunger and barrel, each assembled with a magnet. The plunger moves to noninvasively infuse insulin only when a magnetic field is applied on the exterior surface of the body. Here we show that the dose is easily controlled by varying the number of magnet applications. Also, pump implantation in diabetic rats results in profiles of insulin concentration and decreased blood glucose levels similar to those observed in rats treated with conventional subcutaneous insulin injections.

  11. Surface-Modified Nanocarriers for Nose-to-Brain Delivery: From Bioadhesion to Targeting

    PubMed Central

    Clementino, Adryana; Buttini, Francesca; Colombo, Gaia; Pescina, Silvia; Stanisçuaski Guterres, Silvia; Nicoli, Sara

    2018-01-01

    In the field of nasal drug delivery, nose-to-brain delivery is among the most fascinating applications, directly targeting the central nervous system, bypassing the blood brain barrier. Its benefits include dose lowering and direct brain distribution of potent drugs, ultimately reducing systemic side effects. Recently, nasal administration of insulin showed promising results in clinical trials for the treatment of Alzheimer’s disease. Nanomedicines could further contribute to making nose-to-brain delivery a reality. While not disregarding the need for devices enabling a formulation deposition in the nose’s upper part, surface modification of nanomedicines appears the key strategy to optimize drug delivery from the nasal cavity to the brain. In this review, nanomedicine delivery based on particle engineering exploiting surface electrostatic charges, mucoadhesive polymers, or chemical moieties targeting the nasal epithelium will be discussed and critically evaluated in relation to nose-to-brain delivery. PMID:29543755

  12. Developing a hierarchy of needs for Type 1 diabetes.

    PubMed

    Beran, D

    2014-01-01

    The aim of this study was to use the concept of Maslow's hierarchy of needs and apply this to Type 1 diabetes. Qualitative methods were employed using semi-structured interviews with 101 people from 13 countries. Grounded theory was used for data collection and analysis, with thematic analysis employed to identify the interviewees' needs. Sixteen needs were identified and links between these were mapped. Aligning these with Maslow's hierarchy allowed for a hierarchy to be developed for Type 1 diabetes with 'Policies', 'Organization of health system', 'Insulin', 'Delivery of insulin', 'Control', 'Healthcare workers' and 'Information and education' at the base, as they were needed for survival. Next came 'Community, family and peers' and changing roles for 'Healthcare workers' in their approach to care and delivering 'Information and education'. This enabled people to learn how to use 'Insulin', 'Delivery of insulin' and 'Control' flexibly. People's 'Experience' and 'Personality' then helped them 'Adapt' and 'Be open' about their diabetes, allowing for 'Acceptance' and viewing 'Diabetes as something positive'. Despite limitations, this work highlights that some needs are required for survival and others for well-being. Some are tangible as they can be directly provided, whereas others are intangible and cannot be provided directly by the health system. These results might be used for policy and practice in identifying needs that are met within a health system or what needs are lacking for the individual to then implement targeted interventions. © 2013 The Author. Diabetic Medicine © 2013 Diabetes UK.

  13. 3D printed microneedles for insulin skin delivery.

    PubMed

    Pere, Cristiane Patricia Pissinato; Economidou, Sophia N; Lall, Gurprit; Ziraud, Clémentine; Boateng, Joshua S; Alexander, Bruce D; Lamprou, Dimitrios A; Douroumis, Dennis

    2018-06-15

    In this study, polymeric microneedle patches were fabricated by stereolithography, a 3D printing technique, for the transdermal delivery of insulin. A biocompatible resin was photopolymerized to build pyramid and cone microneedle designs followed by inkjet print coating of insulin formulations. Trehalose, mannitol and xylitol were used as drug carriers with the aim to preserve insulin integrity and stability but also to facilitate rapid release rates. Circular dichroism and Raman analysis demonstrated that all carriers maintained the native form of insulin, with xylitol presenting the best performance. Franz cell release studies were used for in vitro determination of insulin release rates in porcine skin. Insulin was released rapidly within 30 min irrespectively of the microneedle design. 3D printing was proved an effective technology for the fabrication of biocompatible and scalable microneedle patches. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Preparation of chitosan-based multifunctional nanocarriers overcoming multiple barriers for oral delivery of insulin.

    PubMed

    Li, Lei; Jiang, Guohua; Yu, Weijiang; Liu, Depeng; Chen, Hua; Liu, Yongkun; Tong, Zaizai; Kong, Xiangdong; Yao, Juming

    2017-01-01

    To overcome multiple barriers for oral delivery of insulin, the chitosan-based multifunctional nanocarriers modified by L-valine (LV, used as a target ligand to facilitate the absorption of the small intestine) and phenylboronic acid (PBA, used as a glucose-responsive unit) have been designed and evaluated in this study. The resultant nanocarriers exhibited low cytotoxicity against HT-29 cells and excellent stability against protein solution. The insulin release behaviors were evaluated triggered by pH and glucose in vitro. The chemical stability of loaded insulin against digestive enzyme were established in presence of simulated gastric fluid (SGF) containing pepsin and simulated intestinal fluid (SIF) containing pancreatin, respectively. The uptake behavior of HT-29 cells was evaluated by confocal laser scanning microscope. After oral administration to the diabetic rats, an effective hypoglycemic effect was obtained compared with subcutaneous injection of insulin. This work suggests that L-valine modified chitosan-based multifunctional nanocarriers may be a promising drug delivery carrier for oral administration of insulin. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Biotinylated liposomes as potential carriers for the oral delivery of insulin.

    PubMed

    Zhang, Xingwang; Qi, Jianping; Lu, Yi; He, Wei; Li, Xiaoyang; Wu, Wei

    2014-01-01

    This study aimed to explore biotinylated liposomes (BLPs) as novel carriers to enhance the oral delivery of insulin. Biotinylation was achieved by incorporating biotin-conjugated phospholipids into the liposome membranes. A significant hypoglycemic effect and enhanced absorption were observed after treating diabetic rats with the BLPs with a relative bioavailability of 12.09% and 8.23%, based on the measurement of the pharmacologic effect and the blood insulin level, respectively; this achieved bioavailability was approximately double that of conventional liposomes. The significance of the biotinylation was confirmed by the facilitated absorption of the BLPs through receptor-mediated endocytosis, as well as by the improved physical stability of the liposomes. Increased cellular uptake and quick gastrointestinal transport further verified the ability of the BLPs to enhance absorption. These results provide a proof of concept that BLPs can be used as potential carriers for the oral delivery of insulin. Diabetes remains a major source of mortality in the Western world, and advances in its management are expected to have substantial socioeconomic impact. In this paper, biotinylated liposomes were utilized as carriers of insulin for local delivery, demonstrating the feasibility of this approach in a rat model. © 2014.

  16. Multiday Fully Closed Loop Insulin Delivery in Monitored Outpatient Conditions

    ClinicalTrials.gov

    2014-04-29

    To Demonstrate That the Closed Loop System Can be Used Safely Over a Few Consecutive Days.; To Assess Effectiveness in Maintaining Patients' Glucose Levels in the Target Range of 70 to 180 mg/dl, Measured by Blood Glucose Sensor.; To Evaluate the User Experience With a Closed Loop System

  17. Biotechnology Conference: Drug Delivery and Drug Targeting Systems Held in London, United Kingdom on 14-15 December 1987

    DTIC Science & Technology

    1988-07-10

    HPLC ). No significant difference to shaking were always below 20 percent. Therefore the was detected between insulin samples exposed to effect of the...altered tenfold, according to Langer. such as lectin-bound insulin and glucose sensitive In vivo experiments were performed using para membranes...heterogeneity aryl acylamidase to catalyze the production of p- of tumor antigenic expression and the specificity of Mabs, aminophenol (measured at + 250 mV

  18. Oral insulin delivery using P(MAA-g-EG) hydrogels: effects of network morphology on insulin delivery characteristics.

    PubMed

    Nakamura, Koji; Murray, Robert J; Joseph, Jeffrey I; Peppas, Nicholas A; Morishita, Mariko; Lowman, Anthony M

    2004-03-24

    Hydrogels of poly(methacrylic acid-g-ethylene glycol) were prepared using different reaction water contents in order to vary the network mesh size, swelling behavior and insulin loading/release kinetics. Gels prepared with greater reaction solvent contents swelled to a greater degree and had a larger network mesh size. All of the hydrogels were able to incorporate insulin and protected it from release in acidic media. At higher pH (7.4), the release rates increased with reaction solvent content. Using a closed loop animal model, all of the insulin loaded formulations produced significant insulin absorption in the upper small intestine combined with hypoglycemic effects. In these studies, bioavailabilities ranged from 4.6% to 7.2% and were dependent on reaction solvent content.

  19. Gestational weight gain and body mass indexes have an impact on the outcomes of diabetic mothers and infants.

    PubMed

    Maayan-Metzger, Ayala; Schushan-Eisen, Irit; Strauss, Tzipora; Globus, Omer; Leibovitch, Leah

    2015-11-01

    This study evaluated mothers with diabetes to determine whether prepregnancy body mass index (BMI), BMI on delivery or gestational weight gain (GWG) had the greatest impact on maternal and neonatal outcomes. We retrospectively examined the medical charts of 634 full-term infants born to mothers with gestational diabetes mellitus not requiring insulin (n = 476), gestational diabetes mellitus requiring insulin (n = 140) and insulin-dependent diabetes mellitus (n = 18). Data regarding maternal BMI before pregnancy and on delivery were recorded, as well as maternal and neonatal complications. Infants born to women who gained more than the recommended weight during pregnancy had higher birthweights, higher rates of meconium-stained amniotic fluid and neonatal hypoglycaemia. Using logistic regression, Caesarean section delivery was predicted by gestational diabetes requiring insulin, with an odds ratio (OR) of 1.76, maternal hypertension (OR 2.4), infants born large for gestational age (OR 2.78) and maternal BMI ≥ 30 on delivery (OR 1.06). Neonatal complications were predicted by maternal insulin-dependent diabetes (OR 5.21), lower gestational age (OR 0.8) and GWG above the recommended amount (OR 1.56). Women with diabetes should be made aware that higher GWG can lead to Caesarean section delivery, infant macrosomia and other neonatal complications. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. Design and Evaluation of a Robust PID Controller for a Fully Implantable Artificial Pancreas

    PubMed Central

    2015-01-01

    Treatment of type 1 diabetes mellitus could be greatly improved by applying a closed-loop control strategy to insulin delivery, also known as an artificial pancreas (AP). In this work, we outline the design of a fully implantable AP using intraperitoneal (IP) insulin delivery and glucose sensing. The design process utilizes the rapid glucose sensing and insulin action offered by the IP space to tune a PID controller with insulin feedback to provide safe and effective insulin delivery. The controller was tuned to meet robust performance and stability specifications. An anti-reset windup strategy was introduced to prevent dangerous undershoot toward hypoglycemia after a large meal disturbance. The final controller design achieved 78% of time within the tight glycemic range of 80–140 mg/dL, with no time spent in hypoglycemia. The next step is to test this controller design in an animal model to evaluate the in vivo performance. PMID:26538805

  1. Factors Influencing the Effectiveness of Glucagon for Preventing Hypoglycemia

    PubMed Central

    Castle, Jessica R; Engle, Julia M; El Youssef, Joseph; Massoud, Ryan G; Ward, W Kenneth

    2010-01-01

    Background Administration of small, intermittent doses of glucagon during closed-loop insulin delivery markedly reduces the frequency of hypoglycemia. However, in some cases, hypoglycemia occurs despite administration of glucagon in this setting. Methods Fourteen adult subjects with type 1 diabetes participated in 22 closed-loop studies, duration 21.5 ± 2.0 h. The majority of subjects completed two studies, one with insulin + glucagon, given subcutaneously by algorithm during impending hypoglycemia, and one with insulin + placebo. The more accurate of two subcutaneous glucose sensors was used as the controller input. To better understand reasons for success or failure of glucagon to prevent hypoglycemia, each response to a glucagon dose over 0.5 µg/kg was analyzed (n = 19 episodes). Results Hypoglycemia occurred in the hour after glucagon delivery in 37% of these episodes. In the failures, estimated insulin on board was significantly higher versus successes (5.8 ± 0.5 versus 2.9 ± 0.5 U, p < .001). Glucose at the time of glucagon delivery was significantly lower in failures versus successes (86 ± 3 versus 95 ± 3 mg/dl, p = .04). Sensor bias (glucose overestimation) was highly correlated with starting glucose (r = 0.65, p = .002). Prior cumulative glucagon dose was not associated with success or failure. Conclusion Glucagon may fail to prevent hypoglycemia when insulin on board is high or when glucagon delivery is delayed due to overestimation of glucose by the sensor. Improvements in sensor accuracy and delivery of larger or earlier glucagon doses when insulin on board is high may further reduce the frequency of hypoglycemia. PMID:21129324

  2. Factors influencing the effectiveness of glucagon for preventing hypoglycemia.

    PubMed

    Castle, Jessica R; Engle, Julia M; El Youssef, Joseph; Massoud, Ryan G; Ward, W Kenneth

    2010-11-01

    Administration of small, intermittent doses of glucagon during closed-loop insulin delivery markedly reduces the frequency of hypoglycemia. However, in some cases, hypoglycemia occurs despite administration of glucagon in this setting. Fourteen adult subjects with type 1 diabetes participated in 22 closed-loop studies, duration 21.5±2.0 h. The majority of subjects completed two studies, one with insulin + glucagon, given subcutaneously by algorithm during impending hypoglycemia, and one with insulin+placebo. The more accurate of two subcutaneous glucose sensors was used as the controller input. To better understand reasons for success or failure of glucagon to prevent hypoglycemia, each response to a glucagon dose over 0.5 µg/kg was analyzed (n=19 episodes). Hypoglycemia occurred in the hour after glucagon delivery in 37% of these episodes. In the failures, estimated insulin on board was significantly higher versus successes (5.8±0.5 versus 2.9±0.5 U, p<.001). Glucose at the time of glucagon delivery was significantly lower in failures versus successes (86±3 versus 95±3 mg/dl, p=.04). Sensor bias (glucose overestimation) was highly correlated with starting glucose (r=0.65, p=.002). Prior cumulative glucagon dose was not associated with success or failure. Glucagon may fail to prevent hypoglycemia when insulin on board is high or when glucagon delivery is delayed due to overestimation of glucose by the sensor. Improvements in sensor accuracy and delivery of larger or earlier glucagon doses when insulin on board is high may further reduce the frequency of hypoglycemia. © 2010 Diabetes Technology Society.

  3. Phytobioactive compound-based nanodelivery systems for the treatment of type 2 diabetes mellitus – current status

    PubMed Central

    Ganesan, Palanivel; Arulselvan, Palanisamy; Choi, Dong-Kug

    2017-01-01

    Type 2 diabetes mellitus (T2DM) is a major chronic disease that is prevalent worldwide, and it is characterized by an increase in blood glucose, disturbances in the metabolism, and alteration in insulin secretion. Nowadays, food-based therapy has become an important treatment mode for type 2 diabetes, and phytobioactive compounds have gained an increasing amount of attention to this end because they have an effect on multiple biological functions, including the sustained secretion of insulin and regeneration of pancreatic islets cells. However, the poor solubility and lower permeability of these phyto products results in a loss of bioactivity during processing and oral delivery, leading to a significant reduction in the bioavailability of phytobioactive compounds to treat T2DM. Recently, nanotechnological systems have been developed for use as various types of carrier systems to improve the delivery of bioactive compounds and thus obtain a greater bioavailability. Furthermore, carrier systems in most nanodelivery systems are highly biocompatible, with nonimmunologic behavior, a high degree of biodegradability, and greater mucoadhesive strength. Therefore, this review focuses on the various types of nanodelivery systems that can be used for phytobioactive compounds in treating T2DM with greater antidiabetic effects. There is also additional focus on improving the effects of various phytobioactive compounds through nanotechnological delivery to ensure a highly efficient treatment of type 2 diabetes. PMID:28223801

  4. Projections for insulin treatment for diabetics.

    PubMed

    Cao, Ying; Lam, Laura

    2002-06-01

    The evolution of insulin treatment of diabetes has dramatically changed the natural course of this disease. Modern recombinant DNA technology has brought about many new insulin analogues with improved pharmacokinetics, resulting in better glycemic control. In addition, improved insulin delivery systems, such as insulin pumps and pens, have been introduced to provide convenience and to enhance patient compliance. Efforts are currently being devoted to developing noninvasive insulin formulations, such as oral and pulmonary insulin. A number of products are at different stages of clinical trials. Meanwhile, the quest for a permanent cure for diabetes continues. The frontier of diabetes research has gone through a period of substantial expansion, with the emergence of new areas that include gene therapy, islet cell transplantation and diabetic vaccine. Technological breakthroughs, such as recombinant DNA, nanotechnology, microarray-aided genomics and proteomics, will provide more profound insights into the pathogenesis, and the immunological and biological basis of diabetes. Our growing knowledge in these areas will ultimately contribute to the discovery of preventive methods against or a cure for this disease.

  5. The PILGRIM study: in silico modeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise.

    PubMed

    Danne, Thomas; Tsioli, Christiana; Kordonouri, Olga; Blaesig, Sarah; Remus, Kerstin; Roy, Anirban; Keenan, Barry; Lee, Scott W; Kaufman, Francine R

    2014-06-01

    Predictive low glucose management (PLGM) may help prevent hypoglycemia by stopping insulin pump delivery based on predicted sensor glucose values. Hypoglycemic challenges were simulated using the Food and Drug Administration-accepted glucose simulator with 100 virtual patients. PLGM was then tested with a system composed of a Paradigm(®) insulin pump (Medtronic, Northridge, CA), an Enlite™ glucose sensor (Medtronic), and a BlackBerry(®) (Waterloo, ON, Canada)-based controller. Subjects (n=22) on continuous subcutaneous insulin infusion (five females, 17 males; median [range] age, 15 [range, 14-20] years; median [range] diabetes duration, 7 [2-14] years; median [range] glycated hemoglobin, 8.0% [6.7-10.4%]) exercised until the PLGM system suspended insulin delivery or until the reference blood glucose value (HemoCue(®); HemoCue GmbH, Großostheim, Germany) reached the predictive suspension threshold setting. PLGM reduced hypoglycemia (<70 mg/dL) in silico by 26.7% compared with no insulin suspension, as opposed to a 5.3% reduction in hypoglycemia with use of low glucose suspend (LGS). The median duration of hypoglycemia (time spent <70 mg/dL) with PLGM was significantly less than with LGS (58 min vs. 101 min, respectively; P<0.001). In the clinical trial the hypoglycemic threshold during exercise was reached in 73% of the patients, and hypoglycemia was prevented in 80% of the successful experiments. The mean (±SD) sensor glucose at predictive suspension was 92±7 mg/dL, resulting in a postsuspension nadir (by HemoCue) of 77±22 mg/dL. The suspension lasted for 90±35 (range, 30-120) min, resulting in a sensor glucose level at insulin resumption of 97±19 mg/dL. In silico modeling and early feasibility data demonstrate that PLGM may further reduce the severity of hypoglycemia beyond that already established for algorithms that use a threshold-based suspension.

  6. Delivery of two-step transcription amplification exendin-4 plasmid system with arginine-grafted bioreducible polymer in type 2 diabetes animal model

    PubMed Central

    Kim, Pyung-Hwan; Lee, Minhyung; Kim, Sung Wan

    2012-01-01

    Exendin-4, glucagon-like peptide 1 (GLP-1) receptor agonist, is an exocrine hormone, which has potent insulinotropic actions similar to GLP-1 such as stimulating insulin biosynthesis, facilitating glucose-concentration dependent insulin secretion, slowing gastric emptying, reducing food intake and stimulating β-cell proliferation. Exendin-4, also, has a longer half-life than GLP-1, due to itsresistance to degradation by dipeptidyl peptidase IV (DPP-IV). In spite of its many advantages as a therapeutic agent for diabetes, its clinical application is still restricted. Thus, to improve the activity of exendin-4 in vivo, gene therapy system was developed as an alternative method. An exendin-4 expression system was constructed using the two-step transcription amplification (TSTA) system, which is composed of pβ-Gal4-p65 and pUAS-SP-exendin-4 with combining the advantages of signal peptide (SP) in order to facilitate its secretion in ectopic cells or tissue. Arginine-grafted cyctaminebisacrylamide-diaminohexane polymer (ABP) was used as a gene carrier. Increased expression of exendin-4, glucose dependent insulin secretion in NIT-1 insulinoma cells, and high insulin expression in the presence of DPP-IV were evaluated in vitro after delivery of ABP/TSTA-SP-exendin-4. Blood glucose levels in diabetic mice were decreased dramatically from the third day for experimental period after single intravenous administration with ABP/TSTA-SP-exendin-4. The highest insulinotropic effect of exendin-4 was also observed in the ABP/TSTA/SP-exendin-4-treated mice groups, compared with the others groups from the 3rd day after injection. TSTA exendin-4 expression system with SP and ABP polymer has a potential gene therapy for the treatment of type 2 diabetes. PMID:22705459

  7. Insulin Delivery Into the Peripheral Circulation: A Key Contributor to Hypoglycemia in Type 1 Diabetes

    PubMed Central

    Kraft, Guillaume; Scott, Melanie F.; Neal, Doss W.; Farmer, Ben; Smith, Marta S.; Hastings, Jon R.; Allen, Eric J.; Donahue, E. Patrick; Rivera, Noelia; Winnick, Jason J.; Edgerton, Dale S.; Nishimura, Erica; Fledelius, Christian; Brand, Christian L.; Cherrington, Alan D.

    2015-01-01

    Hypoglycemia limits optimal glycemic control in type 1 diabetes mellitus (T1DM), making novel strategies to mitigate it desirable. We hypothesized that portal (Po) vein insulin delivery would lessen hypoglycemia. In the conscious dog, insulin was infused into the hepatic Po vein or a peripheral (Pe) vein at a rate four times of basal. In protocol 1, a full counterregulatory response was allowed, whereas in protocol 2, glucagon was fixed at basal, mimicking the diminished α-cell response to hypoglycemia seen in T1DM. In protocol 1, glucose fell faster with Pe insulin than with Po insulin, reaching 56 ± 3 vs. 70 ± 6 mg/dL (P = 0.04) at 60 min. The change in area under the curve (ΔAUC) for glucagon was similar between Pe and Po, but the peak occurred earlier in Pe. The ΔAUC for epinephrine was greater with Pe than with Po (67 ± 17 vs. 36 ± 14 ng/mL/180 min). In protocol 2, glucose also fell more rapidly than in protocol 1 and fell faster in Pe than in Po, reaching 41 ± 3 vs. 67 ± 2 mg/dL (P < 0.01) by 60 min. Without a rise in glucagon, the epinephrine responses were much larger (ΔAUC of 204 ± 22 for Pe vs. 96 ± 29 ng/mL/180 min for Po). In summary, Pe insulin delivery exacerbates hypoglycemia, particularly in the presence of a diminished glucagon response. Po vein insulin delivery, or strategies that mimic it (i.e., liver-preferential insulin analogs), should therefore lessen hypoglycemia. PMID:26085570

  8. Nanoencapsulation of Insulin into Zirconium Phosphate for Oral Delivery Applications

    PubMed Central

    Díaz, Agustín; David, Amanda; Pérez, Riviam; González, Millie L.; Báez, Adriana; Wark, Stacey E.; Zhang, Paul; Clearfield, Abraham; Colón, Jorge L.

    2010-01-01

    The encapsulation of insulin into different kinds of materials for non-invasive delivery is an important field of study because of the many drawbacks of painful needle and syringe delivery such as physiological stress, infection, and local hypertrophy, among others.1 A stable, robust, non-toxic, and viable non-invasive carrier for insulin delivery is needed. We present a new approach for protein nanoencapsulation using layered zirconium phosphate (ZrP) nanoparticles produced without any preintercalator present. The use of ZrP without preintercalators produces a highly pure material, without any kinds of contaminants, such as the preintercalator, which can be noxious. Cytotoxicity cell viability in vitro experiments for the ZrP nanoparticles show that ZrP is not toxic, or harmful, in a biological environment, as previously reported for rats.2 Contrary to previous preintercalator-based methods, we show that insulin can be nanoencapsulated in ZrP if a highly hydrate phase of ZrP with an interlayer distance of 10.3 Å (10.3 Å-ZrP or θ-ZrP) is used as precursor. The intercalation of insulin into ZrP produced a new insulin-intercalated ZrP phase with a ca. 27 Å interlayer distance, as determined by X-ray powder diffraction, demonstrating a successful nanoencapsulation of the hormone. The in vitro release profile of the hormone after the intercalation was determined and circular dichroism was used to study the hormone stability upon intercalation and release. The insulin remains stable in the layered material, at room temperature, for a considerable amount of time, improving the shell life of the peptidic hormone. This type of materials represents a strong candidate to develop a non-invasive insulin carrier for the treatment of diabetes mellitus. PMID:20707305

  9. Economic Model Predictive Control of Bihormonal Artificial Pancreas System Based on Switching Control and Dynamic R-parameter.

    PubMed

    Tang, Fengna; Wang, Youqing

    2017-11-01

    Blood glucose (BG) regulation is a long-term task for people with diabetes. In recent years, more and more researchers have attempted to achieve automated regulation of BG using automatic control algorithms, called the artificial pancreas (AP) system. In clinical practice, it is equally important to guarantee the treatment effect and reduce the treatment costs. The main motivation of this study is to reduce the cure burden. The dynamic R-parameter economic model predictive control (R-EMPC) is chosen to regulate the delivery rates of exogenous hormones (insulin and glucagon). It uses particle swarm optimization (PSO) to optimize the economic cost function and the switching logic between insulin delivery and glucagon delivery is designed based on switching control theory. The proposed method is first tested on the standard subject; the result is compared with the switching PID and the switching MPC. The effect of the dynamic R-parameter on improving the control performance is illustrated by comparing the results of the EMPC and the R-EMPC. Finally, the robustness tests on meal change (size and timing), hormone sensitivity (insulin and glucagon), and subject variability are performed. All results show that the proposed method can improve the control performance and reduce the economic costs. The simulation results verify the effectiveness of the proposed algorithm on improving the tracking performance, enhancing robustness, and reducing economic costs. The method proposed in this study owns great worth in practical application.

  10. Chitosan nanofibers for transbuccal insulin delivery.

    PubMed

    Lancina, Michael G; Shankar, Roopa Kanakatti; Yang, Hu

    2017-05-01

    In this work, they aimed at producing chitosan based nanofiber mats capable of delivering insulin via the buccal mucosa. Chitosan was electrospun into nanofibers using poly(ethylene oxide) (PEO) as a carrier molecule in various feed ratios. The mechanical properties and degradation kinetics of the fibers were measured. Insulin release rates were determined in vitro using an ELISA assay. The bioactivity of released insulin was measured in terms of Akt activation in pre-adipocytes. Insulin permeation across the buccal mucosa was measured in an ex-vivo porcine transbuccal model. Fiber morphology, mechanical properties, and in vitro stability were dependent on PEO feed ratio. Lower PEO content blends produced smaller diameter fibers with significantly faster insulin release kinetics. Insulin showed no reduction in bioactivity due to electrospinning. Buccal permeation of insulin facilitated by high chitosan content blends was significantly higher than that of free insulin. Taken together, the work demonstrates that chitosan-based nanofibers have the potential to serve as a transbuccal insulin delivery vehicle. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1252-1259, 2017. © 2017 Wiley Periodicals, Inc.

  11. Design, characterization and ex vivo evaluation of chitosan film integrating of insulin nanoparticles composed of thiolated chitosan derivative for buccal delivery of insulin.

    PubMed

    Mortazavian, Elaheh; Dorkoosh, Farid Abedin; Rafiee-Tehrani, Morteza

    2014-05-01

    The purpose of this study is to optimize and characterize of chitosan buccal film for delivery of insulin nanoparticles that were prepared from thiolated dimethyl ethyl chitosan (DMEC-Cys). Insulin nanoparticles composed of chitosan and dimethyl ethyl chitosan (DMEC) were also prepared as control groups. The release of insulin from nanoparticles was studied in vitro in phosphate buffer solution (PBS) pH 7.4. Optimization of chitosan buccal films has been carried out by central composite design (CCD) response surface methodology. Independent variables were different amounts of chitosan and glycerol as mucoadhesive polymer and plasticizer, respectively. Tensile strength and bioadhesion force were considered as dependent variables. Ex vivo study was performed on excised rabbit buccal mucosa. Optimized insulin nanoparticles were obtained with acceptable physicochemical properties. In vitro release profile of insulin nanoparticles revealed that the highest solubility of nanoparticles in aqueous media is related to DMEC-Cys nanoparticles. CCD showed that optimized buccal film containing 4% chitosan and 10% glycerol has 5.81 kg/mm(2) tensile strength and 2.47 N bioadhesion forces. Results of ex vivo study demonstrated that permeation of insulin nanoparticles through rabbit buccal mucosa is 17.1, 67.89 and 97.18% for chitosan, DMEC and DMEC-Cys nanoparticles, respectively. Thus, this study suggests that DMEC-Cys can act as a potential enhancer for buccal delivery of insulin.

  12. Nose-to-Brain Delivery of Peptide Drugs Enhanced by Coadministration of Cell-penetrating Peptides: Therapeutic Potential for Dementia.

    PubMed

    Kamei, Noriyasu

    2017-01-01

    Recent reports suggest that peptide drugs such as insulin have the potential to serve as therapeutics in neurodegenerative diseases such as Alzheimer's disease. However, the transport of these drugs to the therapeutic target, the brain, is significantly hindered by the blood-brain barrier (BBB). Intranasal administration appears to be an ideal solution for drug delivery to the brain, bypassing the BBB, however the entry of peptide drugs into neuronal and epithelial cells in the olfactory mucosa remains low. In this study, we therefore examined whether intranasal coadministration of cell-penetrating peptides (CPPs) could improve nose-to-brain drug transport. In both mice and rats, we found that direct transport of insulin into the brain was significantly facilitated when coadministered with amphipathic CPP penetratin, and eventually insulin reached the deeper regions of the brain such as the hippocampus. In the mouse line senescence-accelerated mouse prone-8 (SAMP8), spatial learning tests demonstrated that long-term intranasal coadministration of insulin with penetratin improved mild memory loss in the early stages of dementia. In contrast, the severe cognitive dysfunction in the aged SAMP8 mice was preserved despite intranasal coadministration of insulin with penetratin. The immunohistological examination of the hippocampus suggested that enhanced nose-to-brain delivery of insulin had a partial neuroprotective effect but unexpectedly increased amyloid β plaque deposition. In conclusion, intranasal coadministration of insulin with CPPs has the potential to serve as a therapeutic for mild cognitive dysfunction. To identify suitable pharmacotherapy for dementia with severe pathology, further studies of nose-to-brain delivery of molecularly appropriate biopharmaceuticals are necessary.

  13. Insulin regulates Glut4 confinement in plasma membrane clusters in adipose cells.

    PubMed

    Lizunov, Vladimir A; Stenkula, Karin; Troy, Aaron; Cushman, Samuel W; Zimmerberg, Joshua

    2013-01-01

    Insulin-stimulated delivery of glucose transporter-4 (GLUT4) to the plasma membrane (PM) is the hallmark of glucose metabolism. In this study we examined insulin's effects on GLUT4 organization in PM of adipose cells by direct microscopic observation of single monomers tagged with photoswitchable fluorescent protein. In the basal state, after exocytotic delivery only a fraction of GLUT4 is dispersed into the PM as monomers, while most of the GLUT4 stays at the site of fusion and forms elongated clusters (60-240 nm). GLUT4 monomers outside clusters diffuse freely and do not aggregate with other monomers. In contrast, GLUT4 molecule collision with an existing cluster can lead to immediate confinement and association with that cluster. Insulin has three effects: it shifts the fraction of dispersed GLUT4 upon delivery, it augments the dissociation of GLUT4 monomers from clusters ∼3-fold and it decreases the rate of endocytic uptake. All together these three effects of insulin shift most of the PM GLUT4 from clustered to dispersed states. GLUT4 confinement in clusters represents a novel kinetic mechanism for insulin regulation of glucose homeostasis.

  14. Novel Simple Insulin Delivery Device Reduces Barriers to Insulin Therapy in Type 2 Diabetes

    PubMed Central

    Hermanns, Norbert; Lilly, Leslie C.; Mader, Julia K.; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R.

    2015-01-01

    Background: The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. Methods: This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Results: Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = −5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = −2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. Conclusions: The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. PMID:25670847

  15. Novel simple insulin delivery device reduces barriers to insulin therapy in type 2 diabetes: results from a pilot study.

    PubMed

    Hermanns, Norbert; Lilly, Leslie C; Mader, Julia K; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R

    2015-05-01

    The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = -5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = -2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. © 2015 Diabetes Technology Society.

  16. Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover study.

    PubMed

    Bally, Lia; Thabit, Hood; Kojzar, Harald; Mader, Julia K; Qerimi-Hyseni, Jehona; Hartnell, Sara; Tauschmann, Martin; Allen, Janet M; Wilinska, Malgorzata E; Pieber, Thomas R; Evans, Mark L; Hovorka, Roman

    2017-04-01

    Tight control of blood glucose concentration in people with type 1 diabetes predisposes to hypoglycaemia. We aimed to investigate whether day-and-night hybrid closed-loop insulin delivery can improve glucose control while alleviating the risk of hypoglycaemia in adults with HbA 1c below 7·5% (58 mmol/mol). In this open-label, randomised, crossover study, we recruited adults (aged ≥18 years) with type 1 diabetes and HbA 1c below 7·5% from Addenbrooke's Hospital (Cambridge, UK) and Medical University of Graz (Graz, Austria). After a 2-4 week run-in period, participants were randomly assigned (1:1), using web-based randomly permuted blocks of four, to receive insulin via the day-and-night hybrid closed-loop system or usual pump therapy for 4 weeks, followed by a 2-4 week washout period and then the other intervention for 4 weeks. Treatment interventions were unsupervised and done under free-living conditions. During the closed-loop period, a model-predictive control algorithm directed insulin delivery, and prandial insulin delivery was calculated with a standard bolus wizard. The primary outcome was the proportion of time when sensor glucose concentration was in target range (3·9-10·0 mmol/L) over the 4 week study period. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT02727231, and is completed. Between March 21 and June 24, 2016, we recruited 31 participants, of whom 29 were randomised. One participant withdrew during the first closed-loop period because of dissatisfaction with study devices and glucose control. The proportion of time when sensor glucose concentration was in target range was 10·5 percentage points higher (95% CI 7·6-13·4; p<0·0001) during closed-loop delivery compared with usual pump therapy (65·6% [SD 8·1] when participants used usual pump therapy vs 76·2% [6·4] when they used closed-loop). Compared with usual pump therapy, closed-loop delivery also reduced the proportion of time spent in hypoglycaemia: the proportion of time with glucose concentration below 3·5 mmol/L was reduced by 65% (53-74, p<0·0001) and below 2·8 mmol/L by 76% (59-86, p<0·0001). No episodes of serious hypoglycaemia or other serious adverse events occurred. Use of day-and-night hybrid closed-loop insulin delivery under unsupervised, free-living conditions for 4 weeks in adults with type 1 diabetes and HbA 1c below 7·5% is safe and well tolerated, improves glucose control, and reduces hypoglycaemia burden. Larger and longer studies are warranted. Swiss National Science Foundation (P1BEP3_165297), JDRF, UK National Institute for Health Research Cambridge Biomedical Research Centre, and Wellcome Strategic Award (100574/Z/12/Z). Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  17. Insulin Therapy Improves Adeno-Associated Virus Transduction of Liver and Skeletal Muscle in Mice and Cultured Cells.

    PubMed

    Carrig, Sean; Bijjiga, Enoch; Wopat, Mitchell J; Martino, Ashley T

    2016-11-01

    Adeno-associated virus (AAV) gene transfer is a promising treatment for genetic abnormalities. Optimal AAV vectors are showing success in clinical trials. Gene transfer to skeletal muscle and liver is being explored as a potential therapy for some conditions, that is, α 1 -antitrypsin (AAT) disorder and hemophilia B. Exploring approaches that enhance transduction of liver and skeletal muscle, using these vectors, is beneficial for gene therapy. Regulating hormones as an approach to improve AAV transduction is largely unexplored. In this study we tested whether insulin therapy improves liver and skeletal muscle gene transfer. In vitro studies demonstrated that the temporary coadministration (2, 8, and 24 hr) of insulin significantly improves AAV2-CMV-LacZ transduction of cultured liver cells and differentiated myofibers, but not of lung cells. In addition, there was a dose response related to this improved transduction. Interestingly, when insulin was not coadministered with the virus but given 24 hr afterward, there was no increase in the transgene product. Insulin receptor gene (INSR) expression levels were increased 5- to 13-fold in cultured liver cells and differentiated myofibers when compared with lung cells. Similar INSR gene expression profiles occurred in mouse tissues. Insulin therapy was performed in mice, using a subcutaneously implanted insulin pellet or a high-carbohydrate diet. Insulin treatment began just before intramuscular delivery of AAV1-CMV-schFIX or liver-directed delivery of AAV8-CMV-schFIX and continued for 28 days. Both insulin augmentation therapies improved skeletal muscle- and liver-directed gene transduction in mice as seen by a 3.0- to 4.5-fold increase in human factor IX (hFIX) levels. The improvement was observed even after the insulin therapy ended. Monitoring insulin showed that insulin levels increased during the brief period of rAAV delivery and during the entire insulin augmentation period (28 days). This study demonstrates that AAV transduction of liver or skeletal muscle can be improved by insulin therapy.

  18. Updates on smart polymeric carrier systems for protein delivery.

    PubMed

    El-Sherbiny, Ibrahim; Khalil, Islam; Ali, Isra; Yacoub, Magdi

    2017-10-01

    Smart materials are those materials that are responsive to chemical (organic molecules, chemical agents or specific agents), biochemical (protein, enzymes, growth factors, substrates or ligands), physical (electric field, magnetic field, temperature, pH, ionic strength or radiation) or mechanical (pressure or mechanical stress) signals. These responsive materials interact with the stimuli by changing their properties or conformational structures in a predictable manner. Recently, smart polymers have been utilized in various biomedical applications. Particularly, they have been used as a platform to synthesize stimuli-responsive systems that could deliver therapeutics to a specific site for a specific period with minimal adverse effects. For instance, stimuli-responsive polymers-based systems have been recently reported to deliver different bioactive molecules such as carbohydrates (heparin), chemotherapeutic agents (doxorubicin), small organic molecules (anti-coagulants), nucleic acids (siRNA), and proteins (growth factors and hormones). Protein therapeutics played a fundamental role in treatment of various chronic and some autoimmune diseases. For instance insulin has been used in treatment of diabetes. However, being a protein in nature, insulin delivery is limited by its instability, short half-life, and easy denaturation when administered orally. To overcome these challenges, and as highlighted in this review article, much research efforts have been recently devoted to design and develop convenient smart controlled nanosystems for protein therapeutics delivery.

  19. A sophisticated programmable miniaturised pump for insulin delivery.

    PubMed

    Klein, J C; Slama, G

    1980-09-01

    We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.

  20. Alizarin Complexone Functionalized Mesoporous Silica Nanoparticles: A Smart System Integrating Glucose-Responsive Double-Drugs Release and Real-Time Monitoring Capabilities.

    PubMed

    Zou, Zhen; He, Dinggeng; Cai, Linli; He, Xiaoxiao; Wang, Kemin; Yang, Xue; Li, Liling; Li, Siqi; Su, Xiaoya

    2016-04-06

    The outstanding progress of nanoparticles-based delivery systems capable of releasing hypoglycemic drugs in response to glucose has dramatically changed the outlook of diabetes management. However, the developed glucose-responsive systems have not offered real-time monitoring capabilities for accurate quantifying hypoglycemic drugs released. In this study, we present a multifunctional delivery system that integrates both delivery and monitoring issues using glucose-triggered competitive binding scheme on alizarin complexone (ALC) functionalized mesoporous silica nanoparticles (MSN). In this system, ALC is modified on the surface of MSN as the signal reporter. Gluconated insulin (G-Ins) is then introduced onto MSN-ALC via benzene-1,4-diboronic acid (BA) mediated esterification reaction, where G-Ins not only blocks drugs inside the mesopores but also works as a hypoglycemic drug. In the absence of glucose, the sandwich-type boronate ester structure formed by BA binding to the diols of ALC and G-Ins remains intact, resulting in an fluorescence emission peak at 570 nm and blockage of pores. Following a competitive binding, the presence of glucose cause the dissociation of boronate ester between ALC and BA, which lead to the pores opening and disappearance of fluorescence. As proof of concept, rosiglitazone maleate (RSM), an insulin-sensitizing agent, was doped into the MSN to form a multifunctional MSN (RSM@MSN-ALC-BA-Ins), integrating with double-drugs loading, glucose-responsive performance, and real-time monitoring capability. It has been demonstrated that the glucose-responsive release behaviors of insulin and RSM in buffer or in human serum can be quantified in real-time through evaluating the changes of fluorescence signal. We believe that this developed multifunctional system can shed light on the invention of a new generation of smart nanoformulations for optical diagnosis, individualized treatment, and noninvasive monitoring of diabetes management.

  1. Peptide and protein delivery using new drug delivery systems.

    PubMed

    Jain, Ashish; Jain, Aviral; Gulbake, Arvind; Shilpi, Satish; Hurkat, Pooja; Jain, Sanjay K

    2013-01-01

    Pharmaceutical and biotechnological research sorts protein drug delivery systems by importance based on their various therapeutic applications. The effective and potent action of the proteins/peptides makes them the drugs of choice for the treatment of numerous diseases. Major research issues in protein delivery include the stabilization of proteins in delivery devices and the design of appropriate target-specific protein carriers. Many efforts have been made for effective delivery of proteins/peptidal drugs through various routes of administrations for successful therapeutic effects. Nanoparticles made of biodegradable polymers such as poly lactic acid, polycaprolactone, poly(lactic-co-glycolic acid), the poly(fumaric-co-sebacic) anhydride chitosan, and modified chitosan, as well as solid lipids, have shown great potential in the delivery of proteins/peptidal drugs. Moreover, scientists also have used liposomes, PEGylated liposomes, niosomes, and aquasomes, among others, for peptidal drug delivery. They also have developed hydrogels and transdermal drug delivery systems for peptidal drug delivery. A receptor-mediated delivery system is another attractive strategy to overcome the limitation in drug absorption that enables the transcytosis of the protein across the epithelial barrier. Modification such as PEGnology is applied to various proteins and peptides of the desired protein and peptides also increases the circulating life, solubility and stability, pharmacokinetic properties, and antigenicity of protein. This review focuses on various approaches for effective protein/peptidal drug delivery, with special emphasis on insulin delivery.

  2. Nanolayer encapsulation of insulin-chitosan complexes improves efficiency of oral insulin delivery

    PubMed Central

    Song, Lei; Zhi, Zheng-liang; Pickup, John C

    2014-01-01

    Current oral insulin formulations reported in the literature are often associated with an unpredictable burst release of insulin in the intestine, which may increase the risk for problematic hypoglycemia. The aim of the study was to develop a solution based on a nanolayer encapsulation of insulin-chitosan complexes to afford sustained release after oral administration. Chitosan/heparin multilayer coatings were deposited onto insulin-chitosan microparticulate cores in the presence of poly(ethylene) glycol (PEG) in the precipitating and coating solutions. The addition of PEG improved insulin loading and minimized an undesirable loss of the protein resulting from redissolution. Nanolayer encapsulation and the formation of complexes enabled a superior loading capacity of insulin (>90%), as well as enhanced stability and 74% decreased solubility at acid pH in vitro, compared with nonencapsulated insulin. The capsulated insulin administered by oral gavage lowered fasting blood glucose levels by up to 50% in a sustained and dose-dependent manner and reduced postprandial glycemia in streptozotocin-induced diabetic mice without causing hypoglycemia. Nanolayer encapsulation reduced the possibility of rapid and erratic falls of blood glucose levels in animals. This technique represents a promising strategy to promote the intestinal absorption efficiency and release behavior of the hormone, potentially enabling an efficient and safe route for oral insulin delivery of insulin in diabetes management. PMID:24833901

  3. Insulin pump risks and benefits: a clinical appraisal of pump safety standards, adverse event reporting and research needs. A joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group.

    PubMed

    Heinemann, Lutz; Fleming, G Alexander; Petrie, John R; Holl, Reinhard W; Bergenstal, Richard M; Peters, Anne L

    2015-05-01

    Insulin pump therapy, also known as continuous subcutaneous insulin infusion (CSII), is an important and evolving form of insulin delivery, which is mainly used for people with type 1 diabetes. However, even with modern insulin pumps, errors of insulin infusion can occur due to pump failure, insulin infusion set (IIS) blockage, infusion site problems, insulin stability issues, user error or a combination of these. Users are therefore exposed to significant and potentially fatal hazards: interruption of insulin infusion can result in hyperglycaemia and ketoacidosis; conversely, delivery of excessive insulin can cause severe hypoglycaemia. Nevertheless, the available evidence on the safety and efficacy of CSII remains limited. The European Association for the Study of Diabetes (EASD) and American Diabetes Association (ADA) have therefore joined forces to review the systems in place for evaluating the safety of pumps from a clinical perspective. We found that useful information held by the manufacturing companies is not currently shared in a sufficiently transparent manner. Public availability of adverse event (AE) reports on the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database is potentially a rich source of safety information but is insufficiently utilised due to the current configuration of the system; the comparable database in Europe (European Databank on Medical Devices, EUDAMED) is not publicly accessible. Many AEs appear to be attributable to human factors and/or user error, but the extent to which manufacturing companies are required by regulators to consider the interactions of users with the technical features of their products is limited. The clinical studies required by regulators prior to marketing are small and over-reliant on bench testing in relation to 'predicate' products. Once a pump is available on the market, insufficient data are made publicly available on its long-term use in a real-world setting; such data could provide vital information to help healthcare teams to educate and support users, and thereby prevent AEs. As well as requiring more from the manufacturing companies, we call for public funding of more research addressing clinically important questions in relation to pump therapy: both observational studies and clinical trials. At present there are significant differences in the regulatory systems between the USA and European Union at both pre- and post-marketing stages; improvements in the European system are more urgently required. This statement concludes with a series of recommended specific actions for 'meknovigilance' (i.e. a standardised safety approach to technology) which could be implemented to address the shortcomings we highlight.

  4. L-Valine appended PLGA nanoparticles for oral insulin delivery.

    PubMed

    Jain, Ashish; Jain, Sanjay K

    2015-08-01

    Oral insulin delivery has been the major research issue, since many decades, due to several obvious advantages over other routes. However, this route poses several constraints for the delivery of peptides and proteins which are to be worked upon. The small intestine has been shown to be able to transport the L-forms of amino acids against a concentration gradient and that they compete for the mechanism concerned. So, L-valine was used as a ligand for carrier-mediated transport of insulin-loaded polylactic-co-glycolic acid (PLGA) nanoparticles (NPs). L-Valine-conjugated PLGA nanoparticles were prepared using double emulsion solvent evaporation method. The NPs and conjugated NPs were characterized for their size, drug entrapment efficiency, zeta potential, polydispersity index and in vitro insulin release. Ex vivo studies on intestine revealed that conjugated nanoparticles showed greater insulin uptake as compared to non-conjugated nanoparticles. In vivo studies were performed on streptozotocin-induced diabetic rabbits. Oral suspension of insulin-loaded PLGA nanoparticles reduced blood glucose level from 265.4 ± 8.5 to 246.6 ± 2.4 mg/dL within 4 h which further decreased to 198.7 ± 7.1 mg/dL value after 8 h. The ligand-conjugated formulation on oral administration produced hypoglycaemic effect (216.9 ± 1.9 mg/dL) within 4 h of administration, and the hypoglycaemic effect prolonged till 12 h of oral administration. Simultaneously, the insulin concentration in withdrawn samples was also assessed and found that profile of insulin level is in compliance with the blood glucose reduction profile. Hence, it is concluded that the L-valine-conjugated NPs bearing insulin are the promising carrier for the transportation of insulin across the intestine on oral administration.

  5. Awake, long-term intranasal insulin treatment does not affect object memory, odor discrimination, or reversal learning in mice

    PubMed Central

    Bell, Genevieve A.; Fadool, Debra Ann

    2017-01-01

    Intranasal insulin delivery is currently being used in clinical trials to test for improvement in human memory and cognition, and in particular, for lessening memory loss attributed to neurodegenerative diseases. Studies have reported the effects of short-term intranasal insulin treatment on various behaviors, but less have examined long-term effects. The olfactory bulb contains the highest density of insulin receptors in conjunction with the highest level of insulin transport within the brain. Previous research from our laboratory has demonstrated that acute insulin intranasal delivery (IND) enhanced both short- and long-term memory as well as increased two-odor discrimination in a two-choice paradigm. Herein, we investigated the behavioral and physiological effects of chronic insulin IND. Adult, male C57BL6/J mice were intranasally treated with 5 μg/μl of insulin twice daily for 30 and 60 days. Metabolic assessment indicated no change in body weight, caloric intake, or energy expenditure following chronic insulin IND, but an increase in the frequency of meal bouts selectively in the dark cycle. Unlike acute insulin IND, which has been shown to cause enhanced performance in odor habituation/dishabituation and two-odor discrimination tasks in mice, chronic insulin IND did not enhance olfactometry-based odorant discrimination or olfactory reversal learning. In an object memory recognition task, insulin IND-treated mice performed no different from controls regardless of task duration. Biochemical analyses of the olfactory bulb revealed a modest 1.3X increase in IR kinase phosphorylation but no significant increase in Kv1.3 phosphorylation. Substrate phosphorylation of IR Kinase downstream effectors (MAPK/ERK and Akt signaling) proved to be highly variable. These data indicate that chronic administration of insulin IND in mice fails to enhance olfactory ability, object memory recognition, or a majority of systems physiology metabolic factors – as reported to elicit a modulatory effect with acute administration. This leads to two alternative interpretations regarding long-term insulin IND in mice: 1) It causes an initial stage of insulin resistance to dampen the behaviors that would normally be modulated under acute insulin IND, but ability to clear a glucose challenge is still retained, or 2) There is a lack of behavioral modulation at high concentration of insulin attributed to the twice daily intervals of hyperinsulinemia caused by insulin IND administration without any insulin resistance, per se. PMID:28259806

  6. Awake, long-term intranasal insulin treatment does not affect object memory, odor discrimination, or reversal learning in mice.

    PubMed

    Bell, Genevieve A; Fadool, Debra Ann

    2017-05-15

    Intranasal insulin delivery is currently being used in clinical trials to test for improvement in human memory and cognition, and in particular, for lessening memory loss attributed to neurodegenerative diseases. Studies have reported the effects of short-term intranasal insulin treatment on various behaviors, but less have examined long-term effects. The olfactory bulb contains the highest density of insulin receptors in conjunction with the highest level of insulin transport within the brain. Previous research from our laboratory has demonstrated that acute insulin intranasal delivery (IND) enhanced both short- and long-term memory as well as increased two-odor discrimination in a two-choice paradigm. Herein, we investigated the behavioral and physiological effects of chronic insulin IND. Adult, male C57BL6/J mice were intranasally treated with 5μg/μl of insulin twice daily for 30 and 60days. Metabolic assessment indicated no change in body weight, caloric intake, or energy expenditure following chronic insulin IND, but an increase in the frequency of meal bouts selectively in the dark cycle. Unlike acute insulin IND, which has been shown to cause enhanced performance in odor habituation/dishabituation and two-odor discrimination tasks in mice, chronic insulin IND did not enhance olfactometry-based odorant discrimination or olfactory reversal learning. In an object memory recognition task, insulin IND-treated mice did not perform differently than controls, regardless of task duration. Biochemical analyses of the olfactory bulb revealed a modest 1.3 fold increase in IR kinase phosphorylation but no significant increase in Kv1.3 phosphorylation. Substrate phosphorylation of IR kinase downstream effectors (MAPK/ERK and Akt signaling) proved to be highly variable. These data indicate that chronic administration of insulin IND in mice fails to enhance olfactory ability, object memory recognition, or a majority of systems physiology metabolic factors - as reported to elicit a modulatory effect with acute administration. This leads to two alternative interpretations regarding long-term insulin IND in mice: 1) It causes an initial stage of insulin resistance to dampen the behaviors that would normally be modulated under acute insulin IND, but ability to clear a glucose challenge is still retained, or 2) There is a lack of behavioral modulation at high concentration of insulin attributed to the twice daily intervals of hyperinsulinemia caused by insulin IND administration without any insulin resistance, per se. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Hypoglycaemia incidence and recovery during home use of hybrid closed-loop insulin delivery in adults with type 1 diabetes.

    PubMed

    Ruan, Yue; Bally, Lia; Thabit, Hood; Leelarathna, Lalantha; Hartnell, Sara; Tauschmann, Martin; Wilinska, Malgorzata E; Evans, Mark L; Mader, Julia K; Kojzar, Harald; Dellweg, Sibylle; Benesch, Carsten; Arnolds, Sabine; Pieber, Thomas R; Hovorka, Roman

    2018-03-25

    Glucose excursion was assessed prior to and post hypoglycaemia to increase understanding of hypoglycaemia incidence and recovery during hybrid closed-loop insulin delivery. We retrospectively analysed data from 60 adults with type 1 diabetes who received, in a crossover randomized design, day-and-night hybrid closed-loop insulin delivery and insulin pump therapy, the latter with or without real-time continuous glucose monitoring. Over 4-week study periods, we identified hypoglycaemic episodes, defined as sensor glucose <3.0 mmol/L, and analysed sensor glucose relative to the onset of hypoglycaemia. We identified 377 hypoglycaemic episodes during hybrid closed-loop intervention vs 662 during control intervention (P < .001), with a predominant reduction of nocturnal hypoglycaemia. The slope of sensor glucose prior to hypoglycaemia was steeper during closed-loop intervention than during control intervention (P < .01), while insulin delivery was reduced (P < .01). During both day and night, participants recovered from hypoglycaemia faster when treated by closed-loop intervention. At 120 minutes post hypoglycaemia, sensor glucose levels were higher during closed-loop intervention compared to the control period (P < .05). In conclusion, closed-loop intervention reduces the risk of hypoglycaemia, particularly overnight, with swift recovery from hypoglycaemia leading to higher 2-hour post-hypoglycaemia glucose levels. © 2018 John Wiley & Sons Ltd.

  8. Probing insulin bioactivity in oral nanoparticles produced by ultrasonication-assisted emulsification/internal gelation

    PubMed Central

    Lopes, Marlene A; Abrahim-Vieira, Bárbara; Oliveira, Claudia; Fonte, Pedro; Souza, Alessandra M T; Lira, Tammy; Sequeira, Joana A D; Rodrigues, Carlos R; Cabral, Lúcio M; Sarmento, Bruno; Seiça, Raquel; Veiga, Francisco; Ribeiro, António J

    2015-01-01

    Alginate–dextran sulfate-based particles obtained by emulsification/internal gelation technology can be considered suitable carriers for oral insulin delivery. A rational study focused on the emulsification and particle recovery steps was developed in order to reduce particles to the nanosize range while keeping insulin bioactivity. There was a decrease in size when ultrasonication was used during emulsification, which was more pronounced when a cosurfactant was added. Ultrasonication add-on after particle recovery decreased aggregation and led to a narrower nanoscale particle-size distribution. Insulin encapsulation efficiency was 99.3%±0.5%, attributed to the strong pH-stabilizing electrostatic effect between insulin and nanoparticle matrix polymers. Interactions between these polymers and insulin were predicted using molecular modeling studies through quantum mechanics calculations that allowed for prediction of the interaction model. In vitro release studies indicated well-preserved integrity of nanoparticles in simulated gastric fluid. Circular dichroism spectroscopy proved conformational stability of insulin and Fourier transform infrared spectroscopy technique showed rearrangements of insulin structure during processing. Moreover, in vivo biological activity in diabetic rats revealed no statistical difference when compared to nonencapsulated insulin, demonstrating retention of insulin activity. Our results demonstrate that alginate–dextran sulfate-based nanoparticles efficiently stabilize the loaded protein structure, presenting good physical properties for oral delivery of insulin. PMID:26425087

  9. The Relationship between 25-hydroxyvitamin D Levels, Insulin Sensitivity and Insulin Secretion in Women 3 Years after Delivery.

    PubMed

    Tänczer, Tímea; Magenheim, Rita; Fürst, Ágnes; Domján, Beatrix; Janicsek, Zsófia; Szabó, Eszter; Ferencz, Viktória; Tabák, Ádám G

    2017-12-01

    There is a direct correlation between 25-hydroxyvitamin D (25[OH]D) levels and insulin sensitivity. Furthermore, women with gestational diabetes (GDM) may have lower levels of 25(OH)D compared to controls. The present study intended to investigate 25(OH)D levels and their association with insulin sensitivity and insulin secretion in women with prior GDM and in controls 3.2 years after delivery. A total of 87 patients with prior GDM and 45 randomly selected controls (age range, 22 to 44 years) with normal glucose tolerance during pregnancy nested within a cohort of all deliveries at Saint Margit Hospital, Budapest, between January 1 2005, and December 31 2006, were examined. Their 25(OH) D levels were measured by radioimmunoassay. Insulin sensitivity and fasting insulin secretion were estimated using the homeostasis model asssessment (HOMA) calculator and early insulin secretion by the insulinogenic index based on a 75 g oral glucose tolerance test. There was no significant difference in 25(OH)D levels between cases and controls (27.2±13.1 [±SD] vs. 26.9±9.8 ng/L). There was a positive association between HOMA insulin sensitivity and 25(OH)D levels (beta = 0.017; 95% CI 0.001 to 0.034/1 ng/mL) that was robust to adjustment for age and body mass index. There was a nonsignificant association between HOMA insulin secretion and 25(OH)D (p=0.099), while no association was found with the insulinogenic index. Prior GDM status was not associated with 25(OH)D levels; however, 25(OH) D levels were associated with HOMA insulin sensitivity. It is hypothesized that the association between HOMA insulin secretion and 25(OH)D levels is related to the autoregulation of fasting glucose levels because no association between 25(OH)D and insulinogenic index was found. Copyright © 2017 Diabetes Canada. Published by Elsevier Inc. All rights reserved.

  10. Closed-Loop Insulin Delivery for Adults with Type 1 Diabetes Undertaking High-Intensity Interval Exercise Versus Moderate-Intensity Exercise: A Randomized, Crossover Study.

    PubMed

    Jayawardene, Dilshani C; McAuley, Sybil A; Horsburgh, Jodie C; Gerche, André La; Jenkins, Alicia J; Ward, Glenn M; MacIsaac, Richard J; Roberts, Timothy J; Grosman, Benyamin; Kurtz, Natalie; Roy, Anirban; O'Neal, David N

    2017-06-01

    We aimed to compare closed-loop glucose control for people with type 1 diabetes undertaking high-intensity interval exercise (HIIE) versus moderate-intensity exercise (MIE). Adults with type 1 diabetes established on insulin pumps undertook HIIE and MIE stages in random order during automated insulin delivery via a closed-loop system (Medtronic). Frequent venous sampling for glucose, lactate, ketones, insulin, catecholamines, cortisol, growth hormone, and glucagon levels was performed. The primary outcome was plasma glucose <4.0 mmol/L for ≥15 min, from exercise commencement to 120 min postexercise. Secondary outcomes included continuous glucose monitoring and biochemical parameters. Twelve adults (age mean ± standard deviation 40 ± 13 years) were recruited; all completed the study. Plasma glucose of one participant fell to 3.4 mmol/L following MIE completion; no glucose levels were <4.0 mmol/L for HIIE (primary outcome). There were no glucose excursions >15.0 mmol/L for either stage. Mean (±standard error) plasma glucose did not differ between stages pre-exercise; was higher during exercise in HIIE than MIE (11.3 ± 0.5 mmol/L vs. 9.7 ± 0.6 mmol/L, respectively; P < 0.001); and remained higher until 60 min postexercise. There were no differences in circulating free insulin before, during, or postexercise. During HIIE compared with MIE, there were greater increases in lactate (P < 0.001), catecholamines (all P < 0.05), and cortisol (P < 0.001). Ketones increased more with HIIE than MIE postexercise (P = 0.031). Preliminary findings suggest that closed-loop glucose control is safe for people undertaking HIIE and MIE. However, the management of the postexercise rise in ketones secondary to counter-regulatory hormone-induced insulin resistance observed with HIIE may represent a challenge for closed-loop systems.

  11. Update on Mathematical Modeling Research to Support the Development of Automated Insulin Delivery Systems

    DTIC Science & Technology

    2010-05-01

    that believed the delay is ≤10–15 min, 50% believed that insulin can cause changes in the blood (i.e., plasma)-to-ISF glucose gradient. Also, 50% still...by the R01HL88448-1 grant, which seeks to establish safe pediatric euglycemia after cardiac surgery in neonates using continuous glucose monitoring...2062–7. 9. Burge MR, Castillo KR, Schade DS. Meal composition is a determinant of lispro-induced hypoglycemia in IDDM. Diabetes Care. 1997;20(2):152–5

  12. In vitro and in vivo testing of glucose-responsive insulin-delivery microdevices in diabetic rats.

    PubMed

    Chu, Michael K L; Chen, Jian; Gordijo, Claudia R; Chiang, Simon; Ivovic, Alexander; Koulajian, Khajag; Giacca, Adria; Wu, Xiao Yu; Sun, Yu

    2012-07-21

    We have developed glucose-responsive implantable microdevices for closed-loop delivery of insulin and conducted in vivo testing of these devices in diabetic rats. The microdevices consist of an albumin-based bioinorganic membrane that utilizes glucose oxidase (GOx), catalase (CAT) and manganese dioxide (MnO(2)) nanoparticles to convert a change in the environmental glucose level to a pH stimulus, which regulates the volume of pH-sensitive hydrogel nanoparticles and thereby the permeability of the membrane. The membrane is integrated with microfabricated PDMS (polydimethylsiloxane) structures to form compact, stand-alone microdevices, which do not require tethering wires or tubes. During in vitro testing, the microdevices showed glucose-responsive insulin release over multiple cycles at clinically relevant glucose concentrations. In vivo, the microdevices were able to counter hyperglycemia in diabetic rats over a one-week period. The in vitro and in vivo testing results demonstrated the efficacy of closed-loop biosensing and rapid response of the 'smart' insulin delivery devices.

  13. Smart approaches to glucose-responsive drug delivery.

    PubMed

    Webber, Matthew J; Anderson, Daniel G

    2015-01-01

    A grand challenge in the field of "smart" drug delivery has been the quest to create formulations that can sense glucose and respond by delivering an appropriate dose of insulin. This approach, referred to as the "fully synthetic pancreas", envisions closed-loop insulin therapy. The strategies for incorporating glucose sensing into formulations can be broadly categorized into three subsets: enzymatic sensing, natural glucose-binding proteins and synthetic molecular recognition. Here, we highlight some examples of each of these approaches. The challenges remaining en route to the realization of closed-loop insulin therapy are substantial, and include improved response time, more authentic fidelity in glycemic control, improved biocompatibility for delivery materials and assurance of both safety and efficacy. The ubiquitous existence of glucose, combined with the unstable and toxic properties of insulin, further compound efforts towards the generation of a fully synthetic pancreas. However, given the growing incidence of both type-1 and type-2 diabetes, there is significant potential impact from the realization of such an approach on improving therapeutic management of the disease.

  14. Identifying and meeting the challenges of insulin therapy in type 2 diabetes.

    PubMed

    Sorli, Christopher; Heile, Michael K

    2014-01-01

    Type 2 diabetes mellitus (T2DM) is a chronic illness that requires clinical recognition and treatment of the dual pathophysiologic entities of altered glycemic control and insulin resistance to reduce the risk of long-term micro- and macrovascular complications. Although insulin is one of the most effective and widely used therapeutic options in the management of diabetes, it is used by less than one-half of patients for whom it is recommended. Clinician-, patient-, and health care system-related challenges present numerous obstacles to insulin use in T2DM. Clinicians must remain informed about new insulin products, emerging technologies, and treatment options that have the potential to improve adherence to insulin therapy while optimizing glycemic control and mitigating the risks of therapy. Patient-related challenges may be overcome by actively listening to the patient's fears and concerns regarding insulin therapy and by educating patients about the importance, rationale, and evolving role of insulin in individualized self-treatment regimens. Enlisting the services of Certified Diabetes Educators and office personnel can help in addressing patient-related challenges. Self-management of diabetes requires improved patient awareness regarding the importance of lifestyle modifications, self-monitoring, and/or continuous glucose monitoring, improved methods of insulin delivery (eg, insulin pens), and the enhanced convenience and safety provided by insulin analogs. Health care system-related challenges may be improved through control of the rising cost of insulin therapy while making it available to patients. To increase the success rate of treatment of T2DM, the 2012 position statement from the American Diabetes Association and the European Association for the Study of Diabetes focused on individualized patient care and provided clinicians with general treatment goals, implementation strategies, and tools to evaluate the quality of care.

  15. Intranasal Neuropeptide Administration To Target the Human Brain in Health and Disease.

    PubMed

    Spetter, Maartje S; Hallschmid, Manfred

    2015-08-03

    Central nervous system control of metabolic function relies on the input of endocrine messengers from the periphery, including the pancreatic hormone insulin and the adipokine leptin. This concept primarily derives from experiments in animals where substances can be directly applied to the brain. A feasible approach to study the impact of peptidergic messengers on brain function in humans is the intranasal (IN) route of administration, which bypasses the blood-brain barrier and delivers neuropeptides to the brain compartment, but induces considerably less, if any, peripheral uptake than other administration modes. Experimental IN insulin administration has been extensively used to delineate the role of brain insulin signaling in the control of energy homeostasis, but also cognitive function in healthy humans. Clinical pilot studies have found beneficial effects of IN insulin in patients with memory deficits, suggesting that the IN delivery of this and other peptides bears some promise for new, selectively brain-targeted pharmaceutical approaches in the treatment of metabolic and cognitive disorders. More recently, experiments relying on the IN delivery of the hypothalamic hormone oxytocin, which is primarily known for its involvement in psychosocial processes, have provided evidence that oxytocin influences metabolic control in humans. The IN administration of leptin has been successfully tested in animal models but remains to be investigated in the human setting. We briefly summarize the literature on the IN administration of insulin, leptin, and oxytocin, with a particular focus on metabolic effects, and address limitations and perspectives of IN neuropeptide administration.

  16. Development and in vivo evaluation of an oral insulin-PEG delivery system.

    PubMed

    Calceti, P; Salmaso, S; Walker, G; Bernkop-Schnürch, A

    2004-07-01

    Insulin-monomethoxypoly(ethylene glycol) derivatives were obtained by preparation of mono- and di-terbutyl carbonate insulin derivatives, reaction of available protein amino groups with activated 750 Da PEG and, finally, amino group de-protection. This procedure allowed for obtaining high yield of insulin-1PEG and insulin-2PEG. In vivo studies carried out by subcutaneous injection into diabetic mice demonstrated that the two bioconjugates maintained the native biological activity. In vitro, PEGylation was found to enhance the hormone stability towards proteases. After 1 h incubation with elastase, native insulin, insulin-1PEG and insulin-2PEG undergo about 70, 30 and 10% degradation, respectively, while in the presence of pepsin protein degradation was 100, 70 and 50%, respectively. The attachment of low molecular weight PEG did not significantly (P >0.05) alter insulin permeation behavior across the intestinal mucosa. Insulin-1PEG was formulated into mucoadhesive tablets constituted by the thiolated polymer poly(acrylic acid)-cysteine. The therapeutic agent was sustained released from these tablets within 5 h. In vivo, by oral administration to diabetic mice, the glucose levels were found to decrease of about 40% since the third hour from administration and the biological activity was maintained up to 30 h. According to these results, the combination of PEGylated insulin with a thiolated polymer used as drug carrier matrix might be a promising strategy for oral insulin administration.

  17. Insulin delivery device technology 2012: where are we after 90 years?

    PubMed

    Fry, Andrew

    2012-07-01

    Since the first successful use of insulin in 1921 to treat diabetes at Toronto General Hospital, the major advances in development of the medication itself have taken place in parallel with equally significant developments in the means of delivery. Administration of insulin remains parenteral. This article reviews the main variants in prescription-available delivery technology: vial and syringe, pen injector, needle-free injection, and continuous subcutaneous insulin infusion pumps. For each of these, the background and major milestones are covered briefly and followed by a discussion of the latest product innovations, technologies, and implementations, which are all considered in the context of the interaction with users. The article concludes by reflecting upon how the progress in the technology of diabetes management can best serve the patient. The spectacular technological advances in medication, monitoring, and delivery since 1922 have transformed the lives of millions. However, the fact that we can add sophisticated technology to delivery devices and accessories does not mean it is always the best thing for the patient. Electronic sophistication may be welcomed by a young, eager type 1 diabetes patient, while a senior citizen who discovers he has type 2 diabetes may yearn for simplicity. Technology continues to provide great solutions, but the type of solution delivered must be matched to the user if the maximum benefit is to be achieved for all. © 2012 Diabetes Technology Society.

  18. Insulin Delivery Device Technology 2012: Where Are We after 90 Years?

    PubMed Central

    Fry, Andrew

    2012-01-01

    Since the first successful use of insulin in 1921 to treat diabetes at Toronto General Hospital, the major advances in development of the medication itself have taken place in parallel with equally significant developments in the means of delivery. Administration of insulin remains parenteral. This article reviews the main variants in prescription-available delivery technology: vial and syringe, pen injector, needle-free injection, and continuous subcutaneous insulin infusion pumps. For each of these, the background and major milestones are covered briefly and followed by a discussion of the latest product innovations, technologies, and implementations, which are all considered in the context of the interaction with users. The article concludes by reflecting upon how the progress in the technology of diabetes management can best serve the patient. The spectacular technological advances in medication, monitoring, and delivery since 1922 have transformed the lives of millions. However, the fact that we can add sophisticated technology to delivery devices and accessories does not mean it is always the best thing for the patient. Electronic sophistication may be welcomed by a young, eager type 1 diabetes patient, while a senior citizen who discovers he has type 2 diabetes may yearn for simplicity. Technology continues to provide great solutions, but the type of solution delivered must be matched to the user if the maximum benefit is to be achieved for all. PMID:22920823

  19. Enteric-coated capsules filled with mono-disperse micro-particles containing PLGA-lipid-PEG nanoparticles for oral delivery of insulin.

    PubMed

    Yu, Fei; Li, Yang; Liu, Chang Sheng; Chen, Qin; Wang, Gui Huan; Guo, Wei; Wu, Xue E; Li, Dong Hui; Wu, Winston Duo; Chen, Xiao Dong

    2015-04-30

    The success of the oral delivery of insulin (INS) as a therapeutic protein drug would significantly improve the quality of life of diabetic patients who would otherwise receive multiple daily INS injections. The oral delivery of INS, however, is still limited in its delivery efficiency, which could be due to the chemical, enzymatic, and adsorption barriers. In this work, in an attempt to improve the delivery efficiency, the INS-loaded polymer-lipid hybrid nanoparticles (INS-PLGA-lipid-PEG NPs) were designed and constructed through a double-emulsion solvent evaporation technique, followed by formulation of the spherical micro-particles using a spray freeze dryer (SFD). This kind of dryers has a uniquely designed microfluidic aerosol nozzle (MFAN), ensuring the formation of uniform particles. The resulted particles of ∼212 μm could easily be reverted to discrete INS-PLGA-lipid-PEG NPs in an aqueous solution. The INS-PLGA-lipid-PEG NPs created in this work showed a highly negative surface charge, excellent entrapment efficiency (92.3%) and a sustained drug release (∼24 h). Confocal laser scanning microscopy and flow cytometer were used to show that the cellular uptake efficiency for the INS-PLGA-lipid-PEG NPs was more effective than the INS in Caco-2 cells. More importantly, the in vivo pharmacodynamics demonstrated that the orally delivered system induced a prolonged decrease in blood glucose levels among diabetic rats. The relative bioavailability of INS compared with subcutaneous injection in diabetic rats was found to be approximately 12%. These results suggested that the encapsulated INS-PLGA-lipid-PEG NPs are promising and should be investigated further in the near future as an effective INS oral delivery system. Copyright © 2015. Published by Elsevier B.V.

  20. Iontophoresis of monomeric insulin analogues in vitro: effects of insulin charge and skin pretreatment.

    PubMed

    Langkjaer, L; Brange, J; Grodsky, G M; Guy, R H

    1998-01-23

    The aim of this study was to investigate the influence of association state and net charge of human insulin analogues on the rate of iontophoretic transport across hairless mouse skin, and the effect of different skin pretreatments on said transport. No insulin flux was observed with anodal delivery probably because of degradation at the Ag/AgCl anode. The flux during cathodal iontophoresis through intact skin was insignificant for human hexameric insulin, and only low and variable fluxes were observed for monomeric insulins. Using stripped skin on the other hand, the fluxes of monomeric insulins with two extra negative charges were 50-100 times higher than that of hexameric human insulin. Introducing three additional charges led to a further 2-3-fold increase in flux. Wiping the skin gently with absolute alcohol prior to iontophoresis resulted in a 1000-fold increase in transdermal transport of insulin relative to that across untreated skin, i.e. to almost the same level as stripping the skin. The alcohol pretreatment reduced the electrical resistance of the skin, presumably by lipid extraction. In conclusion, monomeric insulin analogues with at least two extra negative charges can be iontophoretically delivered across hairless mouse skin, whereas insignificant flux is observed with human, hexameric insulin. Wiping the skin with absolute alcohol prior to iontophoresis gave substantially improved transdermal transport of monomeric insulins resulting in clinically relevant delivery rates for basal treatment.

  1. Insulin microcrystal suspension as a long-acting formulation for pulmonary delivery.

    PubMed

    Kwon, Jai-Hyun; Lee, Byung-Ha; Lee, Jae-Jeong; Kim, Chan-Wha

    2004-06-01

    Pulmonary delivery provides the most promising non-parenteral route of insulin administration. Insulin was used as a model protein to demonstrate the feasibility of using protein crystals for the pulmonary delivery of a sustained-release protein drug formulation. Insulin microcrystals with a mean diameter of 3 microm were prepared using a seed zone method. The yield of crystallization was very high (95.8 +/- 0.97%), and the microcrystals were recovered with high efficiency (>98%) by centrifugation. Morphological examination using scanning electron microphotography showed the microcrystals to be of a homogeneous rhombohedral shape, with some rhombus forms, without aggregates. After the administration of 32 U/kg of the microcrystal suspension to STZ-induced diabetic SD rats by intratracheal instillation, the blood glucose levels were reduced and hypoglycemia was prolonged over 13 h, as compared to the insulin solution. The percent minimum reductions of the blood glucose concentration (% MRBG) produced by the microcrystal suspension and insulin solution reached 36.5 and 37.2%, respectively, of the initial level, and the percent total reductions in blood glucose (% TRBG(13 h)) were 34.4 and 25.0%, respectively. In the case of inhalation using a sieve-type ultrasonic nebulizer, the % MRBG produced by the microcrystal suspension and insulin solution were 21.7 and 26.3%, respectively, of the initial level, and the % TRBG(13 h) were 66.7 and 58.4%, respectively. However, the hypoglycemic effects of the microcrystal suspension were prolonged over 7 h, which compares favorably with the insulin solution (P<0.5 by unpaired t-test). These results could be attributed to the sustained-release of insulin from the microcrystals, which were deposited widely throughout the entire lung.

  2. Glucose-Responsive Trehalose Hydrogel for Insulin Stabilization and Delivery.

    PubMed

    Lee, Juneyoung; Ko, Jeong Hoon; Mansfield, Kathryn M; Nauka, Peter C; Bat, Erhan; Maynard, Heather D

    2018-05-01

    Effective delivery of therapeutic proteins is important for many biomedical applications. Yet, the stabilization of proteins during delivery and long-term storage remains a significant challenge. Herein, a trehalose-based hydrogel is reported that stabilizes insulin to elevated temperatures prior to glucose-triggered release. The hydrogel is synthesized using a polymer with trehalose side chains and a phenylboronic acid end-functionalized 8-arm poly(ethylene glycol) (PEG). The hydroxyls of the trehalose side chains form boronate ester linkages with the PEG boronic acid cross-linker to yield hydrogels without any further modification of the original trehalose polymer. Dissolution of the hydrogel is triggered upon addition of glucose as a stronger binder to boronic acid (K b = 2.57 vs 0.48 m -1 for trehalose), allowing the insulin that is entrapped during gelation to be released in a glucose-responsive manner. Moreover, the trehalose hydrogel stabilizes the insulin as determined by immunobinding after heating up to 90 °C. After 30 min heating, 74% of insulin is detected by enzyme-linked immunosorbent assay in the presence of the trehalose hydrogel, whereas only 2% is detected without any additives. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Insulin Regulates Glut4 Confinement in Plasma Membrane Clusters in Adipose Cells

    PubMed Central

    Lizunov, Vladimir A.; Stenkula, Karin; Troy, Aaron; Cushman, Samuel W.; Zimmerberg, Joshua

    2013-01-01

    Insulin-stimulated delivery of glucose transporter-4 (GLUT4) to the plasma membrane (PM) is the hallmark of glucose metabolism. In this study we examined insulin’s effects on GLUT4 organization in PM of adipose cells by direct microscopic observation of single monomers tagged with photoswitchable fluorescent protein. In the basal state, after exocytotic delivery only a fraction of GLUT4 is dispersed into the PM as monomers, while most of the GLUT4 stays at the site of fusion and forms elongated clusters (60–240 nm). GLUT4 monomers outside clusters diffuse freely and do not aggregate with other monomers. In contrast, GLUT4 molecule collision with an existing cluster can lead to immediate confinement and association with that cluster. Insulin has three effects: it shifts the fraction of dispersed GLUT4 upon delivery, it augments the dissociation of GLUT4 monomers from clusters ∼3-fold and it decreases the rate of endocytic uptake. All together these three effects of insulin shift most of the PM GLUT4 from clustered to dispersed states. GLUT4 confinement in clusters represents a novel kinetic mechanism for insulin regulation of glucose homeostasis. PMID:23520472

  4. Clinical Benefits Over Time Associated with Use of V-Go Wearable Insulin Delivery Device in Adult Patients with Diabetes: A Retrospective Analysis.

    PubMed

    Sutton, David; Higdon, Charissa D; Nikkel, Carla; Hilsinger, Karrie A

    2018-05-10

    Advances in insulin delivery have improved outcomes in patients with diabetes. This study evaluated the impact of V-Go ® Wearable Insulin Delivery device on glycated hemoglobin (A1C) and insulin total daily dose (TDD) in patients with diabetes not achieving glycemic targets. Electronic medical record data was obtained for adult patients with A1C > 7% treated at a multicenter endocrine practice who initiated V-Go between August 2012 and August 2015. Data were collected at baseline and for up to four follow-up visits, and were analyzed overall, stratified by insulin use at baseline, and for patients prescribed a basal-bolus insulin regimen delivered by multiple daily injections (MDI) at baseline. Economic evaluations were conducted in patients previously prescribed MDI regimens. Patients (N = 103) were evaluated after a mean of 2, 6, 10, and 14 months of V-Go use. Baseline glycemic control was poor (A1C > 9%) in 59% of patients. Significant, sustained reductions in A1C compared with baseline were observed at every visit (p < 0.0001), with mean ± SE decrease of 1.67 ± 0.24% after 14 months. For patients prescribed insulin at baseline (n = 80), TDD was significantly reduced at all visits (p < 0.0001), with mean ± SE reduction of 17 ± 4.5 units/day at 14 months. Patients previously prescribed MDI therapy (n = 58) benefited from 1.53 ± 0.31% (p < 0.001) A1C reduction and TDD decrease of 30 ± 5 units/day after 14 months. Direct pharmacy wholesale acquisition costs for diabetes therapeutics were reduced by $25.00/patient/month. Use of V-Go was associated with improved glycemic control and decreased TDD. For patients previously prescribed basal-bolus MDI therapy, switching to insulin therapy with V-Go resulted in pharmacy cost savings based on wholesale acquisition costs. V-Go offers an efficacious method of insulin delivery that improves outcomes in patients and can reduce costs. Valeritas, Inc.

  5. In vivo evaluation of thiolated chitosan tablets for oral insulin delivery.

    PubMed

    Millotti, Gioconda; Laffleur, Flavia; Perera, Glen; Vigl, Claudia; Pickl, Karin; Sinner, Frank; Bernkop-Schnürch, Andreas

    2014-10-01

    Chitosan-6-mercaptonicotinic acid (chitosan-6-MNA) is a thiolated chitosan with strong mucoadhesive properties and a pH-independent reactivity. This study aimed to evaluate the in vivo potential for the oral delivery of insulin. The comparison of the nonconjugated chitosan and chitosan-6-MNA was performed on several studies such as mucoadhesion, release, and in vivo studies. Thiolated chitosan formulations were both about 80-fold more mucoadhesive compared with unmodified ones. The thiolated chitosan tablets showed a sustained release for 5 h for the polymer of 20 kDa and 8 h for the polymer of 400 kDa. Human insulin was quantified in rats' plasma by means of ELISA specific for human insulin with no cross-reactivity with the endogenous insulin. In vivo results showed thiolation having a tremendous impact on the absorption of insulin. The absolute bioavailabilities were 0.73% for chitosan-6-MNA of 20 kDa and 0.62% for chitosan-6-MNA 400 kDa. The areas under the concentration-time curves (AUC) of chitosan-6-MNA formulations compared with unmodified chitosan were 4.8-fold improved for the polymer of 20 kDa and 21.02-fold improved for the polymer of 400 kDa. The improvement in the AUC with regard to the most promising aliphatic thiomer was up to 6.8-fold. Therefore, chitosan-6-MNA represents a promising excipient for the oral delivery of insulin. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  6. Formulation, in vitro evaluation and kinetic analysis of chitosan-gelatin bilayer muco-adhesive buccal patches of insulin nanoparticles.

    PubMed

    Mahdizadeh Barzoki, Zahra; Emam-Djomeh, Zahra; Mortazavian, Elaheh; Akbar Moosavi-Movahedi, Ali; Rafiee Tehrani, M

    2016-11-01

    The present study was performed to optimise the formulation of a muco-adhesive buccal patch for insulin nanoparticles (NPs) delivery. Insulin NPs were synthesised by an ionic gelation technique using N-di methyl ethyl chitosan cysteine (DMEC-Cys) as permeation enhancer biopolymer, tripolyphosphate (TPP) and insulin. Buccal patches were developed by solvent-casting technique using chitosan and gelatine as muco-adhesive polymers. Optimised patches were embedded with 3 mg of insulin-loaded NPs with a homogeneous distribution of NPs in the muco-adhesive matrix, which displayed adequate physico-mechanical properties. The drug release characteristics, release mechanism and kinetics were investigated. Data fitting to Peppas equation with a correlation coefficient indicated that the mechanism of drug release followed an anomalous transport that means drug release was afforded through drug diffusion along with polymer erosion. In vitro drug release, release kinetics, physical and mechanical studies for all patch formulations reflected the ideal characteristics of this buccal patch for the delivery of insulin NPs.

  7. Insulin pump use and glycemic control in adolescents with type 1 diabetes: Predictors of change in method of insulin delivery across two years.

    PubMed

    Wong, Jenise C; Dolan, Lawrence M; Yang, Tony T; Hood, Korey K

    2015-12-01

    Few studies have explored durability of insulin pump use, and none have explored the link between depression and pump discontinuation. To examine the relationship between depressive symptoms [measured by the Children's Depression Inventory (CDI)], method of insulin delivery, and hemoglobin A1c (A1c), mixed models were used with data from 150 adolescents with type 1 diabetes (T1D) and visits every 6 months for 2 years. Of the 63% who used a pump, compared with multiple daily injections (MDI) at baseline, there were higher proportions who were non-minorities, had caregivers with a college degree, private insurance, and two caregivers in the home (p ≤ 0.01). After adjusting for time, sex, age, T1D duration, frequency of blood glucose monitoring, ethnicity, insurance, and caregiver number and education, baseline pump use was associated with -0.79% lower mean A1c [95% confidence interval (CI): -1.48, -0.096; p = 0.03]. For those using a pump at baseline, but switching to MDI during the study (n = 9), mean A1c was 1.38% higher (95% CI: 0.68, 2.08; p < 0.001) than that for those who did not switch method of delivery. A 10-point increase in CDI was associated with a 0.39% increase in A1c (95% CI: 0.16, 0.61; p = 0.001), independent of pump use. Regarding the temporal relationship between CDI score and changing method of insulin delivery, prior higher CDI score was associated with switching from pump to MDI (odds ratio = 1.21; 95% CI: 1.05, 1.39; p = 0.007). Clinicians should be aware of the associations between depressive symptoms, change in insulin delivery method, and the effect on glycemic control. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Islet transplantation under the kidney capsule fully corrects the impaired skeletal muscle glucose transport system of streptozocin diabetic rats.

    PubMed Central

    Napoli, R; Davalli, A M; Hirshman, M F; Weitgasser, R; Weir, G C; Horton, E S

    1996-01-01

    Chronic insulin therapy improves but does not restore impaired insulin-mediated muscle glucose uptake in human diabetes or muscle glucose uptake, transport, and transporter translocation in streptozocin diabetic rats. To determine whether this inability is due to inadequate insulin replacement, we studied fasted streptozocin-induced diabetic Lewis rats either untreated or after islet transplantation under the kidney capsule. Plasma glucose was increased in untreated diabetics and normalized by the islet transplantation (110 +/- 5, 452 +/- 9, and 102 +/- 3 mg/dl in controls, untreated diabetics, and transplanted diabetics, respectively). Plasma membrane and intracellular microsomal membrane vesicles were prepared from hindlimb skeletal muscle of basal and maximally insulin-stimulated rats. Islet transplantation normalized plasma membrane carrier-mediated glucose transport Vmax, plasma membrane glucose transporter content, and insulin-induced transporter translocation. There were no differences in transporter intrinsic activity (Vmax/Ro) among the three groups. Microsomal membrane GLUT4 content was reduced by 30% in untreated diabetic rats and normal in transplanted diabetics, whereas the insulin-induced changes in microsomal membrane GLUT4 content were quantitatively similar in the three groups. There were no differences in plasma membrane GLUT1 among the groups and between basal and insulin stimulated states. Microsomal membrane GLUT1 content was increased 60% in untreated diabetics and normalized by the transplantation. In conclusion, an adequate insulin delivery in the peripheral circulation, obtained by islet transplantation, fully restores the muscle glucose transport system to normal in streptozocin diabetic rats. PMID:8617870

  9. Relationship of glucose values to sliding scale insulin (correctional insulin) dose delivery and meal time in acute care patients with diabetes mellitus.

    PubMed

    Trotter, Barbara; Conaway, Mark R; Burns, Suzanne M

    2013-01-01

    Findings of this study suggest the traditional sliding scale insulin (SSI) method does not improve target glucose values among adult medical inpatients. Timing of blood glucose (BC) measurement does affect the required SSI dose. BC measurement and insulin dose administration should be accomplished immediately prior to mealtime.

  10. Microspheres for the oral delivery of insulin: preparation, evaluation and hypoglycaemic effect in streptozotocin-induced diabetic rats.

    PubMed

    Zhang, Huan; Wang, Weimei; Li, Haoran; Peng, Yi; Zhang, Zhiqing

    2018-01-01

    Insulin-loaded microspheres were prepared by alternating deposition film layers that were composed of insulin and poly(vinyl sulfate) potassium on the surface of poly(lactic acid) (PLA) microspheres. The preparation of the insulin-loaded microspheres was optimized by an orthogonal test design, and the relationship between drug loading (DL) and film layers was studied. The particle size, DL and encapsulation efficiency of the obtained insulin-loaded microspheres with 10 films were 5.25 ± 0.15 µm, 111.33 ± 1.15 mg/g and 33.7 ± 0.19%, respectively. Following this, the physical characteristics of the insulin-loaded microspheres were investigated. The results from scanning electron microscopy and a laser particle size analyzer (LPSA) indicated the spherical morphology, rough surface and increasing particle sizes of the insulin-loaded microspheres, which were compared to those of PLA microspheres. An in vitro release study showed that the insulin-loaded microspheres were stable in HCl solution (pH 1.0) and released insulin slowly in phosphate-buffered solution (pH 6.8). Finally, the drug efficacy of the prepared insulin-loaded microspheres via oral administration was evaluated in rats with diabetes induced by streptozotocin, and an obvious dose-dependent hypoglycemic effect was observed. This preliminary data could illustrate the prospect of using microspheres for the oral delivery of insulin.

  11. Temporal changes in sphingolipids and systemic insulin sensitivity during the transition from gestation to lactation

    PubMed Central

    Rico, J. Eduardo; Saed Samii, Sina; Mathews, Alice T.; Lovett, Jacqueline; Haughey, Norman J.; McFadden, Joseph W.

    2017-01-01

    Reduced insulin action develops naturally during the peripartum to ensure maternal nutrient delivery to the fetus and neonate. However, increased insulin resistance can facilitate excessive lipolysis which in turn promotes metabolic disease in overweight dairy cattle. Increased fatty acid availability favors the accumulation of the sphingolipid ceramide and is implicated in the pathogenesis of insulin resistance, however, the relationship between sphingolipid metabolism and insulin resistance during the peripartum remains largely unknown. Our objectives were to characterize temporal responses in plasma and tissue sphingolipids in lean and overweight peripartal cows and to establish the relationships between sphingolipid supply and lipolysis, hepatic lipid deposition, and systemic insulin action. Twenty-one multiparous lean and overweight Holstein cows were enrolled in a longitudinal study spanning the transition from gestation to lactation (d -21 to 21, relative to parturition). Plasma, liver, and skeletal muscle samples were obtained, and sphingolipids were profiled using LC/MS/MS. Insulin sensitivity was assessed utilizing intravenous insulin and glucose challenges. Our results demonstrated the following: first, insulin resistance develops postpartum concurrently with increased lipolysis and hepatic lipid accumulation; second, ceramides and glycosylated ceramides accumulate during the transition from gestation to lactation and are further elevated in overweight cows; third, ceramide accrual is associated with lipolysis and liver lipid accumulation, and C16:0- and C24:0-ceramide are inversely associated with systemic insulin sensitivity postpartum; fourth, plasma sphingomyelin, a potential source of ceramides reaches a nadir at parturition and is closely associated with feed intake; fifth, select sphingomyelins are lower in the plasma of overweight cows during the peripartal period. Our results demonstrate that dynamic changes occur in peripartal sphingolipids that are influenced by adiposity, and are associated with the onset of peripartal insulin resistance. These observations are in agreement with a putative potential role for sphingolipids in facilitating the physiological adaptations of peripartum. PMID:28486481

  12. Glomerular hemodynamic alterations during acute hyperinsulinemia in normal and diabetic rats

    NASA Technical Reports Server (NTRS)

    Tucker, B. J.; Anderson, C. M.; Thies, R. S.; Collins, R. C.; Blantz, R. C.

    1992-01-01

    Treatment of insulin dependent diabetes invariably requires exogenous insulin to control blood glucose. Insulin treatment, independent of other factors associated with insulin dependent diabetes, may induce changes that affect glomerular function. Due to exogenous delivery of insulin in insulin dependent diabetes entering systemic circulation prior to the portal vein, plasma levels of insulin are often in excess of that observed in non-diabetics. The specific effects of hyperinsulinemia on glomerular hemodynamics have not been previously examined. Micropuncture studies were performed in control (non-diabetic), untreated diabetic and insulin-treated diabetic rats 7 to 10 days after administration of 65 mg/kg body weight streptozotocin. After the first period micropuncture measurements were obtained, 5 U of regular insulin (Humulin-R) was infused i.v., and glucose clamped at euglycemic values (80 to 120 mg/dl). Blood glucose concentration in non-diabetic controls was 99 +/- 6 mg/dl. In control rats, insulin infusion and glucose clamp increased nephron filtration rate due to decreases in both afferent and efferent arteriolar resistance (afferent greater than efferent) resulting in increased plasma flow and increased glomerular hydrostatic pressure gradient. However, insulin infusion and glucose clamp produced the opposite effect in both untreated and insulin-treated diabetic rats with afferent arteriolar vasoconstriction resulting in decreases in plasma flow, glomerular hydrostatic pressure gradient and nephron filtration rate. Thromboxane A2 (TX) synthetase inhibition partially decreased the vasoconstrictive response due to acute insulin infusion in diabetic rats preventing the decrease in nephron filtration rate.(ABSTRACT TRUNCATED AT 250 WORDS).

  13. Insulin pump risks and benefits: a clinical appraisal of pump safety standards, adverse event reporting, and research needs: a joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group.

    PubMed

    Heinemann, Lutz; Fleming, G Alexander; Petrie, John R; Holl, Reinhard W; Bergenstal, Richard M; Peters, Anne L

    2015-04-01

    Insulin pump therapy, also known as continuous subcutaneous insulin infusion (CSII), is an important and evolving form of insulin delivery, which is mainly used for people with type 1 diabetes. However, even with modern insulin pumps, errors of insulin infusion can occur due to pump failure, insulin infusion set (IIS) blockage, infusion site problems, insulin stability issues, user error, or a combination of these. Users are therefore exposed to significant and potentially fatal hazards: interruption of insulin infusion can result in hyperglycemia and ketoacidosis; conversely, delivery of excessive insulin can cause severe hypoglycemia. Nevertheless, the available evidence on the safety and efficacy of CSII remains limited. The European Association for the Study of Diabetes (EASD) and the American Diabetes Association (ADA) have therefore joined forces to review the systems in place for evaluating the safety of pumps from a clinical perspective. We found that useful information held by the manufacturing companies is not currently shared in a sufficiently transparent manner. Public availability of adverse event (AE) reports on the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database is potentially a rich source of safety information but is insufficiently utilized due to the current configuration of the system; the comparable database in Europe (European Databank on Medical Devices [EUDAMED]) is not publicly accessible. Many AEs appear to be attributable to human factors and/or user error, but the extent to which manufacturing companies are required by regulators to consider the interactions of users with the technical features of their products is limited. The clinical studies required by regulators prior to marketing are small and over-reliant on bench testing in relation to "predicate" products. Once a pump is available on the market, insufficient data are made publicly available on its long-term use in a real-world setting; such data could provide vital information to help health care teams to educate and support users and thereby prevent AEs. As well as requiring more from the manufacturing companies, we call for public funding of more research addressing clinically important questions in relation to pump therapy: both observational studies and clinical trials. At present, there are significant differences in the regulatory systems between the US and European Union at both pre- and postmarketing stages; improvements in the European system are more urgently required. This statement concludes with a series of recommended specific actions for "meknovigilance" (i.e., a standardized safety approach to technology) that could be implemented to address the shortcomings we highlight. © 2015 by the American Diabetes Association and Springer-Verlag. Copying with attribution allowed for any noncommercial use of the work.

  14. Self-assembled lecithin/chitosan nanoparticles for oral insulin delivery: preparation and functional evaluation.

    PubMed

    Liu, Liyao; Zhou, Cuiping; Xia, Xuejun; Liu, Yuling

    2016-01-01

    Here, we investigated the formation and functional properties of self-assembled lecithin/chitosan nanoparticles (L/C NPs) loaded with insulin following insulin-phospholipid complex preparation, with the aim of developing a method for oral insulin delivery. Using a modified solvent-injection method, insulin-loaded L/C NPs were obtained by combining insulin-phospholipid complexes with L/C NPs. The nanoparticle size distribution was determined by dynamic light scattering, and morphologies were analyzed by cryogenic transmission electron microscopy. Fourier transform infrared spectroscopy analysis was used to disclose the molecular mechanism of prepared insulin-loaded L/C NPs. Fast ultrafiltration and a reversed-phase high-performance liquid chromatography assay were used to separate free insulin from insulin entrapped in the L/C NPs, as well as to measure the insulin-entrapment and drug-loading efficiencies. The in vitro release profile was obtained, and in vivo hypoglycemic effects were evaluated in streptozotocin-induced diabetic rats. Our results indicated that insulin-containing L/C NPs had a mean size of 180 nm, an insulin-entrapment efficiency of 94%, and an insulin-loading efficiency of 4.5%. Cryogenic transmission electron microscopy observations of insulin-loaded L/C NPs revealed multilamellar structures with a hollow core, encircled by several bilayers. In vitro analysis revealed that insulin release from L/C NPs depended on the L/C ratio. Insulin-loaded L/C NPs orally administered to streptozotocin-induced diabetic rats exerted a significant hypoglycemic effect. The relative pharmacological bioavailability following oral administration of L/C NPs was 6.01%. With the aid of phospholipid-complexation techniques, some hydrophilic peptides, such as insulin, can be successfully entrapped into L/C NPs, which could improve oral bioavailability, time-dependent release, and therapeutic activity.

  15. Novel drug delivery system: an immense hope for diabetics.

    PubMed

    Rai, Vineet Kumar; Mishra, Nidhi; Agrawal, Ashish Kumar; Jain, Sanyog; Yadav, Narayan Prasad

    2016-09-01

    Existing medication systems for the treatment of diabetes mellitus (DM) are inconvenient and troublesome for effective and safe delivery of drugs to the specific site. Therefore, investigations are desired to deliver antidiabetics using novel delivery approaches followed by their commercialization. The present review aims to provide a compilation on the latest development in the field of novel drug delivery systems (NDDSs) for antidiabetics with special emphasis on particulate, vesicular and miscellaneous systems. Review of literature (restricted to English language only) was done using electronic databases like Pubmed® and Scirus, i.e. published during 2005-2013. The CIMS/MIMS India Medical Drug Information eBook was used regarding available marketed formulation of antidiabetic drugs. Keywords used were "nanoparticle", "microparticle", "liposomes", "niosomes", "transdermal systems", "insulin", "antidiabetic drugs" and "novel drug delivery systems". Single inclusion was made for one article. If in vivo study was not done then article was seldom included in the manuscript. The curiosity to develop NDDSs of antidiabetic drugs with special attention to the nanoparticulate system followed by microparticulate and lipid-based system is found to emerge gradually to overcome the problems associated with the conventional dosage forms and to win the confidence of end users towards the higher acceptability. In the current scientific panorama when the area of novel drug delivery system has been recognized for its palpable benefits, unique potential of providing physical stability, sustained and site-specific drug delivery for a scheduled period of time can open new vistas for precise, safe and quality treatment of DM.

  16. Effect of varying molecular weight of dextran on acrylic-derivatized dextran and concanavalin A glucose-responsive materials for closed-loop insulin delivery.

    PubMed

    Sahota, Tarsem; Sawicka, Kirsty; Taylor, Joan; Tanna, Sangeeta

    2011-03-01

    Dextran methacrylate (dex-MA) and concanavalin A (con A)-methacrylamide were photopolymerized to produce covalently cross-linked glucose-sensitive gels for the basis of an implantable closed-loop insulin delivery device. The viscoelastic properties of these polymerized gels were tested rheologically in the non-destructive oscillatory mode within the linear viscoelastic range at glucose concentrations between 0 and 5% (w/w). For each cross-linked gel, as the glucose concentration was raised, a decrease in storage modulus, loss modulus and complex viscosity (compared at 1 Hz) was observed, indicating that these materials were glucose responsive. The higher molecular weight acrylic-derivatized dextrans [degree of substitution (DS) 3 and 8%] produced higher complex viscosities across the glucose concentration range. These studies coupled with in vitro diffusion experiments show that dex-MA of 70 kDa and DS (3%) was the optimum mass average molar mass to produce gels that show reduced component leach, glucose responsiveness, and insulin transport useful as part of a self-regulating insulin delivery device.

  17. Insulin delivery through nasal route using thiolated microspheres.

    PubMed

    Nema, Tarang; Jain, Ashish; Jain, Aviral; Shilpi, Satish; Gulbake, Arvind; Hurkat, Pooja; Jain, Sanjay K

    2013-01-01

    The aim of the present study was to investigate the potential of developed thiolated microspheres for insulin delivery through nasal route. In the present study, cysteine was immobilized on carbopol using EDAC. A total of 269.93 µmol free thiol groups per gram polymer were determined. The prepared nonthiolated and thiolated microspheres were studied for particle shape, size, drug content, swellability, mucoadhesion and in vitro insulin release. The thiolated microspheres exhibited higher mucoadhesion due to formation of covalent bonds via disulfide bridges with the mucus gel layer. Drug permeation through goat nasal mucosa of nonthiolated and thiolated microspheres were found as 52.62 ± 2.4% and 78.85 ± 3.1% in 6 h, respectively. Thiolated microspheres bearing insulin showed better reduction in blood glucose level (BGL) in comparison to nonthiolated microspheres as 31.23 ± 2.12% and 75.25 ± 0.93% blood glucose of initial BGL were observed at 6 h after nasal delivery of thiolated and nonthiolated microspheres in streptozotocin-induced diabetic rabbits.

  18. In vitro evaluation of thiolated polydimethylaminoethylmethacrylate hydrogel sub-microparticles for oral insulin delivery.

    PubMed

    Sonia, T A; Sharma, Chandra P

    2013-04-01

    In this investigation, novel cationic thiomer, Thiolated polydimethylaminoethylmethacrylate (PDCys) is synthesised and the feasibility of PDCys sub-microparticles as oral insulin delivery carriers is evaluated in vitro. The presence of both positive charge and thiol group in the same matrix plays a vital role in improving the paracellular permeability. Thiol groups interacts with cysteine rich subdomains via disulfide bond formation and positive charge interacts with sialic residues of mucus glycoproteins via electrostatic interaction, thereby increasing the mucoadhesivity. Cytotoxic evaluation by MTT assay shows that PDCys is nontoxic. Force and Work of adhesion of PDCys was found found to be higher than that of parent polymer. ELISA and Circular dichroism spectra confirms that PDCys retains the biological activity and conformation of insulin. Moreover, PDCys is capable of opening the tight junctions by actin and occludin filament dislocation. Furthermore, permeation of FD4 on Caco-2 cells is improved by 3.9 fold compared to the parent polymer. Preliminary studies suggest that thiolated particles can serve as potential vehicles for oral insulin delivery.

  19. Influence of stabilizers on the physicochemical characteristics of inhaled insulin powders produced by supercritical antisolvent process.

    PubMed

    Kim, Yong Ho; Sioutas, Constantinos; Shing, Katherine S

    2009-01-01

    To examine the effect of stabilizers on aerosol physicochemical characteristics of inhaled insulin particles produced using a supercritical fluid technology. Insulin with stabilizers such as mannitol and trehalose was micronized by aerosol solvent extraction system (ASES). The supercritically-micronized insulin particles were characterized for size, shape, aerosol behavior, crystallinity and secondary structure. Experimental results indicated that when insulin was incorporated with the most commonly used stabilizer mannitol (insulin/mannitol: 15/85 wt.%, designated IM), the particles formed were irregular and needle-shaped and had a tendency to agglomerate. With the incorporation of a second stabilizer trehalose (insulin/mannitol/trehalose: 15/70/15 wt.%, designated IMT), the particles were relatively uniform, more spherical, less cohesive, and less agglomerated in an air flow, when compared to IM particles. The mass median aerodynamic diameter of the IMT particles was 2.32 mum which is suitable for use in inhalation therapy. In vitro deposition test using micro-orifice uniform deposit impactor showed 69 +/- 7 wt.% of the IMT particles was deposited in stage 3, 4, 5 and 6 while 41 +/- 15 wt.% of the IM particles was deposited in the same stages. In terms of insulin stability, secondary structures of insulin particles were not adversely affected by the ASES processing studied here. When properly formulated (as in IMT particles), ASES process can produce particles with appropriate size and size distribution suitable for pulmonary insulin delivery.

  20. Improved insulin loading in poly(lactic-co-glycolic) acid (PLGA) nanoparticles upon self-assembly with lipids.

    PubMed

    García-Díaz, María; Foged, Camilla; Nielsen, Hanne Mørck

    2015-03-30

    Polymeric nanoparticles are widely investigated as drug delivery systems for oral administration. However, the hydrophobic nature of many polymers hampers effective loading of the particles with hydrophilic macromolecules such as insulin. Thus, the aim of this work was to improve the loading of insulin into poly(lactic-co-glycolic) acid (PLGA) nanoparticles by pre-assembly with amphiphilic lipids. Insulin was complexed with soybean phosphatidylcholine or sodium caprate by self-assembly and subsequently loaded into PLGA nanoparticles by using the double emulsion-solvent evaporation technique. The nanoparticles were characterized in terms of size, zeta potential, insulin encapsulation efficiency and loading capacity. Upon pre-assembly with lipids, there was an increased distribution of insulin into the organic phase of the emulsion, eventually resulting in significantly enhanced encapsulation efficiencies (90% as compared to 24% in the absence of lipids). Importantly, the insulin loading capacity was increased up to 20% by using the lipid-insulin complexes. The results further showed that a main fraction of the lipid was incorporated into the nanoparticles and remained associated to the polymer during release studies in buffers, whereas insulin was released in a non-complexed form as a burst of approximately 80% of the loaded insulin. In conclusion, the protein load in PLGA nanoparticles can be significantly increased by employing self-assembled protein-lipid complexes. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Clinical requirements for closed-loop control systems.

    PubMed

    Clarke, William L; Renard, Eric

    2012-03-01

    Closed-loop (CL) therapy systems should be safe, efficacious, and easily manageable for type 1 diabetes mellitus patient use. For the first two clinical requirements, noninferiority and superiority criteria must be determined based on current conventional and intensive therapy outcomes. Current frequencies of hypoglycemia and diabetic ketoacidosis are reviewed and safety expectations for CL therapy systems are proposed. Glycosylated hemoglobin levels lower than current American Diabetes Association recommendations for different age groups are proposed as superiority criteria. Measures of glycemic variability are described and the recording of blood glucose levels as percentages within, above, and below a target range are suggested as reasonable alternatives to sophisticated statistical analyses. It is also suggested that Diabetes Quality of Life and Fear of Hypoglycemia surveys should be used to track psychobehavioral outcomes. Manageability requirements for safe and effective clinical management of CL systems are worth being underscored. The weakest part of the infusion system remains the catheter, which is exposed to variable and under-delivery incidents. Detection methods are needed to warn both the system and the patient about altered insulin delivery, including internal pressure and flow alarms. Glucose monitor sensor accuracy is another requirement; it includes the definition of conditions that lead to capillary glucose measurement, eventually followed by sensor recalibration or replacement. The crucial clinical requirement will be a thorough definition of the situations when the patient needs to move from CL to manual management of insulin delivery, or inversely can switch back to CL after a requested interruption. Instructions about these actions will constitute a major part of the education process of the patients before using CL systems and contribute to the manageability of these systems. © 2012 Diabetes Technology Society.

  2. Prevention of Insulin-Induced Hypoglycemia in Type 1 Diabetes with Predictive Low Glucose Management System.

    PubMed

    Abraham, Mary B; de Bock, Martin; Paramalingam, Nirubasini; O'Grady, Michael J; Ly, Trang T; George, Carly; Roy, Anirban; Spital, Glenn; Karula, Sophy; Heels, Kristine; Gebert, Rebecca; Fairchild, Jan M; King, Bruce R; Ambler, Geoffrey R; Cameron, Fergus; Davis, Elizabeth A; Jones, Timothy W

    2016-07-01

    Sensor-augmented pump therapy (SAPT) with algorithms to predict impending low blood glucose and suspend insulin delivery has the potential to reduce hypoglycemia exposure. The aim of this study was to determine whether predictive low glucose management (PLGM) system is effective in preventing insulin-induced hypoglycemia in controlled experiments. Two protocols were used to induce hypoglycemia in an in-clinic environment. (A) Insulin bolus: Insulin was administered as a manual bolus through the pump. (B) Increased basal insulin: Hypoglycemia was induced by increasing basal rates overnight to 180%. For both protocols, participants were randomized and studied on 2 separate days; a control day with SAPT alone and an intervention day with SAPT and PLGM activated. The predictive algorithm was programmed to suspend basal insulin infusion when sensor glucose was predicted to be <80 mg/dL in 30 min. The primary outcome was the requirement for hypoglycemia treatment (symptomatic hypoglycemia or plasma glucose <50 mg/dL) and was compared in both control and intervention arms. With insulin bolus, 24/28 participants required hypoglycemia treatment with SAPT alone compared to 5/28 participants when PLGM was activated (P ≤ 0.001). With increased basal rates, all the eight SAPT-alone participants required treatment for hypoglycemia compared to only one with SAPT and PLGM. There was no post pump-suspend hyperglycemia with insulin bolus (P = 0.4) or increased basal rates (P = 0.69) in participants with 2-h pump suspension on intervention days. SAPT with PLGM reduced the requirement for hypoglycemia treatment following insulin-induced hypoglycemia in an in-clinic setting.

  3. Development and characterization of lipid-polymeric nanoparticles for oral insulin delivery.

    PubMed

    Sgorla, Débora; Lechanteur, Anna; Almeida, Andreia; Sousa, Flávia; Melo, Eduardo; Bunhak, Élcio; Mainardes, Rubiana; Khalil, Najeh; Cavalcanti, Osvaldo; Sarmento, Bruno

    2018-03-01

    The oral route is widely accepted as the most physiological path for exogenous administration of insulin, as it closely mimic the endogenous insulin pathway. Thus, in this work it is proposed an innovative lipid-polymeric nanocarrier to delivery insulin orally. Areas covered: Nanoparticles were produced through a modified solvent emulsification-evaporation method, using ethyl palmitate and hydroxypropylmethylcellulose acetate succinate as matrix. Lipid-polymeric nanoparticles were around 300 nm in size, negatively charged (-20 mV) and associated insulin with efficiency higher than 80%. Differential scanning calorimetry suggested thermal stability of nanoparticles. In vitro release assays under simulated gastrointestinal conditions resulted in 9% and 14% of insulin released at pH 1.2 during 2 h and at pH 6.8 for 6 h, respectively, demonstrating the ability of those nanoparticles to protect insulin against premature degradation. Importantly, nanoparticles were observed to be safe at potential therapeutic concentrations as did not originate cytotoxicity to intestinal epithelial cells. Lastly, the permeability of nanoencapsulated insulin through Caco-2 monolayers and a triple Caco-2/HT29-MTX/Raji B cell model correlated well with slow release kinetics, and fosters the effectiveness of nanoparticles to promote intestinal absorption of peptidic drugs. Expert opinion: Lipid-polymeric nanoparticles were developed to encapsulate and carry insulin through intestine. Overall, nanoparticles provide insulin stability and intestinal permeability.

  4. Insulin aggregation tracked by its intrinsic TRES

    NASA Astrophysics Data System (ADS)

    Chung, Li Hung C.; Birch, David J. S.; Vyshemirsky, Vladislav; Ryadnov, Maxim G.; Rolinski, Olaf J.

    2017-12-01

    Time-resolved emission spectra (TRES) have been used to detect conformational changes of intrinsic tyrosines within bovine insulin at a physiological pH. The approach offers the ability to detect the initial stages of insulin aggregation at the molecular level. The data analysis has revealed the existence of at least three fluorescent species undergoing dielectric relaxation and significant spectral changes due to insulin aggregation. The results indicate the suitability of the intrinsic TRES approach for insulin studies and for monitoring its stability during storage and aggregation in insulin delivery devices.

  5. Self-assembled lecithin/chitosan nanoparticles for oral insulin delivery: preparation and functional evaluation

    PubMed Central

    Liu, Liyao; Zhou, Cuiping; Xia, Xuejun; Liu, Yuling

    2016-01-01

    Purpose Here, we investigated the formation and functional properties of self-assembled lecithin/chitosan nanoparticles (L/C NPs) loaded with insulin following insulin–phospholipid complex preparation, with the aim of developing a method for oral insulin delivery. Methods Using a modified solvent-injection method, insulin-loaded L/C NPs were obtained by combining insulin–phospholipid complexes with L/C NPs. The nanoparticle size distribution was determined by dynamic light scattering, and morphologies were analyzed by cryogenic transmission electron microscopy. Fourier transform infrared spectroscopy analysis was used to disclose the molecular mechanism of prepared insulin-loaded L/C NPs. Fast ultrafiltration and a reversed-phase high-performance liquid chromatography assay were used to separate free insulin from insulin entrapped in the L/C NPs, as well as to measure the insulin-entrapment and drug-loading efficiencies. The in vitro release profile was obtained, and in vivo hypoglycemic effects were evaluated in streptozotocin-induced diabetic rats. Results Our results indicated that insulin-containing L/C NPs had a mean size of 180 nm, an insulin-entrapment efficiency of 94%, and an insulin-loading efficiency of 4.5%. Cryogenic transmission electron microscopy observations of insulin-loaded L/C NPs revealed multilamellar structures with a hollow core, encircled by several bilayers. In vitro analysis revealed that insulin release from L/C NPs depended on the L/C ratio. Insulin-loaded L/C NPs orally administered to streptozotocin-induced diabetic rats exerted a significant hypoglycemic effect. The relative pharmacological bioavailability following oral administration of L/C NPs was 6.01%. Conclusion With the aid of phospholipid-complexation techniques, some hydrophilic peptides, such as insulin, can be successfully entrapped into L/C NPs, which could improve oral bioavailability, time-dependent release, and therapeutic activity. PMID:26966360

  6. Microemulsions for oral delivery of insulin: design, development and evaluation in streptozotocin induced diabetic rats.

    PubMed

    Sharma, G; Wilson, K; van der Walle, C F; Sattar, N; Petrie, J R; Ravi Kumar, M N V

    2010-10-01

    Insulin loaded microemulsions were developed adopting a low shear reverse micellar approach using didoceyldimethylammonium bromide (DMAB) as the surfactant, propylene glycol (PG) as the co-surfactant, triacetin (TA) as the oil phase and insulin solution as the aqueous phase. A ternary phase diagram was constructed based on multiple cloud point titration to highlight the reverse micellar region. The droplet sizes of the microemulsions were 161.7±24.7nm with PDI of 0.447±0.076 and insulin entrapment of ∼85%. Transmission electron microscopy (TEM) revealed the spherical nature and size homogeneity of the microemulsion droplets. The conformational stability of the entrapped insulin within microemulsions was confirmed by fluorescence spectroscopy and circular dichroism. The microemulsions displayed a 10-fold enhancement in bioavailability compared with plain insulin solution administered per oral in healthy rats. The short-term in vivo efficacy in STZ induced diabetic rats provided the proof of concept by a modest glucose reduction at a dose of 20IU/kg. Together this preliminary data indicate the promise of microemulsions for oral delivery of insulin. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Clinical Evaluation of the Use of a Multifunctional Remotely Controlled Insulin Pump

    PubMed Central

    Pinget, Michel; Lachgar, Karim; Parkin, Christopher G.; Grulet, Hervé; Guillon-Metz, Françoise; Weissmann, Joerg

    2014-01-01

    Current insulin pumps now feature advanced functions for calculating insulin dosages, delivering insulin and analyzing data, however, the perceived usefulness of these functions in clinical settings has not been well studied. We assessed the use and patient perceptions of an insulin delivery system (Accu-Chek® Combo, Roche Diagnostics, Mannheim, Germany) that combines an insulin pump and a handheld multifunctional blood glucose meter with integrated remote control functions. This prospective, observational, multicenter study enrolled 74 type 1 diabetes patients within 13 weeks after starting use of the pump system. At 4 to 24 weeks, investigators collected usage data from the latest 14-day period. Seventy-two patients completed the evaluation, aged 39 ± 15 years, diabetes duration 16 ± 13 years, HbA1c 8.3 ± 1.6%. At follow-up, 62 (86.1%) patients used the remote control for ≥50% of all boluses, 20 (27.8%) used the bolus advisor for ≥50% of all boluses, and 42 (58.3%) viewed at least 1 of the e-logbook reports. More than 95% of users appraised the functions as easy-to-use and useful; median scores from VAS (0 = useless to 100 = indispensable) ranged from 72 to 85. A high percentage of study patients used the system’s advanced features, especially the remote control feature for bolusing. Overall, patients assessed the functions as useful and easy to use. Results support the implementation of these smart capabilities in further insulin pump developments. PMID:25107708

  8. Insulin pumps and insulin quality--requirements and problems.

    PubMed

    Brange, J; Havelund, S

    1983-01-01

    In developing insulin solution suitable for delivery devices the chemical and biological stability, as well as the physical stability, must be taken into consideration. Addition of certain mono- and disaccharides increases the physical stability of neutral insulin solutions, but concurrently the chemical and biological stability decrease to an unacceptable degree. Addition of Ca-ions in low concentrations offers a physiologically acceptable method for stabilizing neutral insulin solutions against heat precipitation without affecting the quality, including the chemical and biological stability.

  9. Meta-Analysis of Maternal and Neonatal Outcomes Associated with the Use of Insulin Glargine versus NPH Insulin during Pregnancy

    PubMed Central

    Lepercq, Jacques; Lin, Jay; Hall, Gillian C.; Wang, Edward; Dain, Marie-Paule; Riddle, Matthew C.; Home, Philip D.

    2012-01-01

    As glargine, an analog of human insulin, is increasingly used during pregnancy, a meta-analysis assessed its safety in this population. A systematic literature search identified studies of gestational or pregestational diabetes comparing use of insulin glargine with human NPH insulin, with at least 15 women in both arms. Data was extracted for maternal outcomes (weight at delivery, weight gain, 1st/3rd trimester HbA1c, severe hypoglycemia, gestation/new-onset hypertension, preeclampsia, and cesarean section) and neonatal outcomes (congenital malformations, gestational age at delivery, birth weight, macrosomia, LGA, 5 minute Apgar score >7, NICU admissions, respiratory distress syndrome, neonatal hypoglycemia, and hyperbilirubinemia). Relative risk ratios and weighted mean differences were determined using a random effect model. Eight studies of women using glargine (331) or NPH (371) were analyzed. No significant differences in the efficacy and safety-related outcomes were found between glargine and NPH use during pregnancy. PMID:22685467

  10. Insulin requirements in late pregnancy in women with type 1 diabetes mellitus: a retrospective review.

    PubMed

    Achong, N; Callaway, L; d'Emden, M; McIntyre, H D; Lust, K; Barrett, H L

    2012-12-01

    Pregnancy in women with type 1 diabetes mellitus (T1DM) is generally associated with increased insulin requirements. To determine the frequency and significance of declining insulin requirements in late gestation in women with T1DM. We conducted a retrospective review of 54 women seen at our institution from 2006 to 2010 with a diagnosis of T1DM pre-pregnancy and presentation for antenatal care prior to 28 weeks. Information was collected regarding patient demographics, insulin dose and pregnancy outcome. A 15% difference in weight-adjusted basal insulin from 30 weeks gestation to delivery was considered significant. Five women (9.3%) had a fall of 15% or more and 23 (42.5%) had a rise of 15% or more rise in insulin requirements. There were fewer neonatal intensive care admissions but more infants with an APGAR <8 at 5 min in women with a fall in insulin requirements. These differences were not evident when the data were re-analysed by quartiles of change. In most women with T1DM, insulin requirements show little change from 30 weeks gestation until delivery. Almost 10% of women had a significant fall in insulin requirements which did not correlate with adverse neonatal outcome. These results require validation in a larger, prospective trial. Crown Copyright © 2012. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Microemulsions containing lecithin and sugar-based surfactants: nanoparticle templates for delivery of proteins and peptides.

    PubMed

    Graf, Anja; Ablinger, Elisabeth; Peters, Silvia; Zimmer, Andreas; Hook, Sarah; Rades, Thomas

    2008-02-28

    Two pseudo-ternary systems comprising isopropyl myristate, soybean lecithin, water, ethanol and either decyl glucoside (DG) or capryl-caprylyl glucoside (CCG) as surfactant were investigated for their potential to form microemulsion templates to produce nanoparticles as drug delivery vehicles for proteins and peptides. All microemulsion and nanoparticle compounds used were pharmaceutically acceptable and biocompatible. Phase diagrams were established and characterized using polarizing light microscopy, viscosity, conductivity, electron microscopy, differential scanning calorimetry and self-diffusion NMR. An area in the phase diagrams containing optically isotropic, monophasic systems was designated as the microemulsion region and systems therein identified as solution-type microemulsions. Poly(alkylcyanoacrylate) nanoparticles prepared by interfacial polymerisation from selected microemulsions ranged from 145 to 660nm in size with a unimodal size distribution depending on the type of monomer (ethyl (2) or butyl (2) cyanoacrylate) and microemulsion template. Generally larger nanoparticles were formed by butyl (2) cyanoacrylate. Insulin was added as a model protein and did not alter the physicochemical behaviour of the microemulsions or the morphology of the nanoparticles. However, insulin-loaded nanoparticles in the CCG containing system decreased in size when using butyl (2) cyanoacrylate. This study shows that microemulsions containing sugar-based surfactants are suitable formulation templates for the formation of nanoparticles to deliver peptides.

  12. Systemic delivery of insulin via the nasal route using a new microemulsion system: In vitro and in vivo studies.

    PubMed

    Sintov, Amnon C; Levy, Haim V; Botner, Shafir

    2010-12-01

    The main purpose of this study was to investigate the nasal absorption of insulin from a new microemulsion spray preparation in rabbits. The bioavailability of insulin lispro via the nasal route using a W/O microemulsion was found to reach 21.5% relative to subcutaneous administration, whereas the use of an inverse microemulsion as well as a plain solution yielded less than 1% bioavailability. The profile of plasma glucose levels obtained after nasal spray application of the microemulsion (1IU/kg lispro) was similar to the subcutaneous profile of 0.5IU/kg at the first 90min after application and resulted in a 30-40% drop in glucose levels. The microemulsion system was characterized by DLS, TEM, viscosity measurements, and by construction of pseudo-ternary phase diagram. The average droplet size of an insulin-unloaded and insulin-loaded microemulsions containing 20% aqueous phase (surfactants-to-oil ratio=87:13) was 2nm and 2.26nm in diameter, respectively. In addition, the effect of the microemulsion on FITC-labeled insulin permeation was examined across the porcine nasal mucosa in vitro. The permeability coefficient of FITC-insulin via the microemulsion was 0.210±0.048cm/h with a lag time of 10.9±6.5min, whereas the permeability coefficient from a plain solution was 0.082±0.043cm/h with a lag time of 36.3±10.1min. In view of the absorption differences of insulin between 20%, 50% water-containing microemulsions and an aqueous solution obtained in vitro and in vivo, it has been concluded that the acceleration in the intramucosal transport process is the result of encapsulating insulin within the nano-droplet clusters of a W/O microemulsion, while the microemulsion ingredients seems to have no direct role. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Secretory expression and surface display of a new and biologically active single-chain insulin (SCI-59) analog by lactic acid bacteria.

    PubMed

    Mao, Ruifeng; Wu, Dongli; Hu, Shimeng; Zhou, Kangping; Wang, Man; Wang, Yefu

    2017-04-01

    Insulin plays an important role in drug therapies for diabetes mellitus and as the main route of insulin delivery, subcutaneous injection may cause local discomfort, hypoglycemia, hyperinsulinemia, and patient non-compliance. Therefore, oral delivery of insulin is more preferred. However, there is a low bioavailability due to insulin degradation by proteolytic enzymes and severe pH conditions along the gastrointestinal tract. In order to use the food-grade bacteria lactic acid bacteria (LAB) as oral delivery vehicles, a new and bioactive single-chain insulin (SCI-59) analog, containing the insulin B- and A-chains connected by an eight-residue linker (RSRGLPFR), was secretory expressed in Lactococcus lactis NZ3900 without using an antibiotic resistance gene and displayed onto the surface of various non-viable bacteria (NVBs) without genetic modification. Both the free SCI-59 and SCI-59 displayed on the surface of NVBs are biologically active as assayed by their ability to stimulate Akt signaling in differentiated 3T3-L1 adipocytes. Modification of the pH of the medium by NaOH addition at early time during induction can enhance the bioactivity of SCI-59. The C-terminal fused anchoring domain, three LysM repeats, does not affect the formation of disulfide bonds and/or the folding of SCI-59, and SCI-59 could be exposed properly and fully when SCI-59-3LysM bound to the surface of NVBs. Compared to the free form SCI-59, SCI-59 displayed on the surface of NVBs is more stable in simulate gastric juice. It may open new prospects for possible oral treatments of diabetes using live LAB secreting or NVBs carrying bioactive SCI analogs.

  14. Stimuli sensitive polymethacrylic acid microparticles (PMAA)--oral insulin delivery.

    PubMed

    Victor, Sunita Prem; Sharma, Chandra P

    2002-10-01

    This study investigated polymethacrylic acid (PMAA) microparticles for controlled release of Insulin in oral administration. The microparticles were characterised by scanning electron microscopy (SEM) for morphological studies. The swelling behaviour and drug release profile in various pH media were studied. The % swelling of gels was found to be inversely related to the amount of crosslinker added. Inclusion complex of betaCD and Insulin was studied using polyacrylamide gel electrophoresis (PAGE). Optimum complexation was obtained in the ratio 100 mg betaCD: 200 IU Insulin. The release pattern of Insulin from Insulin-betaCD complex encapsulated PMAA microparticles showed release of Insulin for more than seven hours.

  15. Hypoglycemia Prevention and User Acceptance of an Insulin Pump System with Predictive Low Glucose Management.

    PubMed

    Choudhary, Pratik; Olsen, Birthe S; Conget, Ignacio; Welsh, John B; Vorrink, Linda; Shin, John J

    2016-05-01

    The MiniMed 640G sensor-augmented insulin pump system (Medtronic, Inc., Northridge, CA) can automatically suspend insulin delivery in advance of predicted hypoglycemia and restart it upon recovery. The aims of this analysis were to determine the rate at which predicted hypoglycemia was avoided with this strategy, as well as to assess user acceptance of the system and its insulin management features. Forty subjects with type 1 diabetes used the system for 4 weeks. We retrospectively evaluated performance of the system, using downloaded pump and sensor data, and evaluated user acceptance via questionnaires. There were 2,322 suspend before low events (2.1 per subject-day). The mean (± SD) duration of pump suspension events was 56.4 ± 9.6 min, and the mean subsequent sensor glucose (SG) nadir was 71.8 ± 5.2 mg/dL. SG values following 1,930 (83.1%) of the predictive suspensions did not reach the preset low limit. Nadir SG values of ≤50 and ≤60 mg/dL were seen in 207 (8.9%) and 356 (15.3%) of the predictive suspensions, respectively. Blood glucose (BG) and SG values before and during the study were comparable (P > 0.05). The mean absolute relative difference between paired SG and BG values was 10.9 ± 13.8%. Subjects felt confident using the system, agreed that it helped protect them from hypoglycemia, and wished to continue using it. Automatic insulin pump suspension as implemented in the MiniMed 640G system can help patients avoid hypoglycemia, without significantly increasing hyperglycemia.

  16. Sequential delivery of BMP-2 and IGF-1 using a chitosan gel with gelatin microspheres enhances early osteoblastic differentiation

    PubMed Central

    Kim, Sungwoo; Kang, Yunqing; Krueger, Chad A.; Sen, Milan; Holcomb, John B.; Chen, Di; Wenke, Joseph C.; Yang, Yunzhi

    2012-01-01

    The purpose of this study was to develop and characterize a chitosan gel/gelatin microspheres (MSs) dual delivery system for sequential release of bone morphogenetic protein-2 (BMP-2) and insulin-like growth factor-1 (IGF-1) to enhance osteoblast differentiation in vitro. We made and characterized the delivery system based on its degree of cross-linking, degradation, and release kinetics. We also evaluated the cytotoxicity of the delivery system and the effect of growth factors on cell response using pre-osteoblast W-20-17 mouse bone marrow stromal cells. IGF-1 was first loaded into MSs, and then the IGF-1 containing MSs were encapsulated into the chitosan gel which contained BMP-2. Cross-linking of gelatin with glyoxal via Schiff bases significantly increased thermal stability and decreased the solubility of the MSs, leading to a significant decrease in the initial release of IGF-1. Encapsulation of the MSs into the chitosan gel generated polyelectrolyte complexes by intermolecular interactions, which further affected the release kinetics of IGF-1. This combinational delivery system provided an initial release of BMP-2 followed by a slow and sustained release of IGF-1. Significantly greater alkaline phosphatase activity was found in W-20-17 cells treated with the sequential delivery system than other treatments (p<0.05) after a week of culture. PMID:22293583

  17. Hydrogel Microencapsulated Insulin-Secreting Cells Increase Keratinocyte Migration, Epidermal Thickness, Collagen Fiber Density, and Wound Closure in a Diabetic Mouse Model of Wound Healing.

    PubMed

    Aijaz, Ayesha; Faulknor, Renea; Berthiaume, François; Olabisi, Ronke M

    2015-11-01

    Wound healing is a hierarchical process of intracellular and intercellular signaling. Insulin is a potent chemoattractant and mitogen for cells involved in wound healing. Insulin's potential to promote keratinocyte growth and stimulate collagen synthesis in fibroblasts is well described. However, there currently lacks an appropriate delivery mechanism capable of consistently supplying a wound environment with insulin; current approaches require repeated applications of insulin, which increase the chances of infecting the wound. In this study, we present a novel cell-based therapy that delivers insulin to the wound area in a constant or glucose-dependent manner by encapsulating insulin-secreting cells in nonimmunogenic poly(ethylene glycol) diacrylate (PEGDA) hydrogel microspheres. We evaluated cell viability and insulin secretory characteristics of microencapsulated cells. Glucose stimulation studies verified free diffusion of glucose and insulin through the microspheres, while no statistical difference in insulin secretion was observed between cells in microspheres and cells in monolayers. Scratch assays demonstrated accelerated keratinocyte migration in vitro when treated with microencapsulated cells. In excisional wounds on the dorsa of diabetic mice, microencapsulated RIN-m cells accelerated wound closure by postoperative day 7; a statistically significant increase over AtT-20ins-treated and control groups. Histological results indicated significantly greater epidermal thickness in both microencapsulated RIN-m and AtT-20ins-treated wounds. The results suggest that microencapsulation enables insulin-secreting cells to persist long enough at the wound site for a therapeutic effect and thereby functions as an effective delivery vehicle to accelerate wound healing.

  18. Recent Advances in Nanotechnology for Diabetes Treatment

    PubMed Central

    DiSanto, Rocco Michael; Subramanian, Vinayak; Gu, Zhen

    2015-01-01

    Nanotechnology in diabetes research has facilitated the development of novel glucose measurement and insulin delivery modalities which hold the potential to dramatically improve quality of life for diabetics. Recent progress in the field of diabetes research at its interface with nanotechnology is our focus. In particular, we examine glucose sensors with nanoscale components including metal nanoparticles and carbon nanostructures. The addition of nanoscale components commonly increases glucose sensor sensitivity, temporal response, and can lead to sensors which facilitate continuous in vivo glucose monitoring. Additionally, we survey nanoscale approaches to “closed-loop” insulin delivery strategies which automatically release insulin in response to fluctuating blood glucose levels. “Closing the loop” between blood glucose level (BGL) measurements and insulin administration by removing the requirement of patient action holds the potential to dramatically improve the health and quality of life of diabetics. Advantages and limitations of current strategies, as well as future opportunities and challenges are also discussed. PMID:25641955

  19. Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes.

    PubMed

    Murphy, Helen R; Elleri, Daniela; Allen, Janet M; Harris, Julie; Simmons, David; Rayman, Gerry; Temple, Rosemary; Dunger, David B; Haidar, Ahmad; Nodale, Marianna; Wilinska, Malgorzata E; Hovorka, Roman

    2011-02-01

    This study evaluated closed-loop insulin delivery with a model predictive control (MPC) algorithm during early (12-16 weeks) and late gestation (28-32 weeks) in pregnant women with type 1 diabetes. Ten women with type 1 diabetes (age 31 years, diabetes duration 19 years, BMI 24.1 kg/m(2), booking A1C 6.9%) were studied over 24 h during early (14.8 weeks) and late pregnancy (28.0 weeks). A nurse adjusted the basal insulin infusion rate from continuous glucose measurements (CGM), fed into the MPC algorithm every 15 min. Mean glucose and time spent in target (63-140 mg/dL), hyperglycemic (>140 to ≥ 180 mg/dL), and hypoglycemic (<63 to ≤ 50 mg/dL) were calculated using plasma and sensor glucose measurements. Linear mixed-effects models were used to compare glucose control during early and late gestation. During closed-loop insulin delivery, median (interquartile range) plasma glucose levels were 117 (100.8-154.8) mg/dL in early and 126 (109.8-140.4) mg/dL in late gestation (P = 0.72). The overnight mean (interquartile range) plasma glucose time in target was 84% (50-100%) in early and 100% (94-100%) in late pregnancy (P = 0.09). Overnight mean (interquartile range) time spent hyperglycemic (>140 mg/dL) was 7% (0-40%) in early and 0% (0-6%) in late pregnancy (P = 0.25) and hypoglycemic (<63 mg/dL) was 0% (0-3%) and 0% (0-0%), respectively (P = 0.18). Postprandial glucose control, glucose variability, insulin infusion rates, and CGM sensor accuracy were no different in early or late pregnancy. MPC algorithm performance was maintained throughout pregnancy, suggesting that overnight closed-loop insulin delivery could be used safely during pregnancy. More work is needed to achieve optimal postprandial glucose control.

  20. Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes

    PubMed Central

    Murphy, Helen R.; Elleri, Daniela; Allen, Janet M.; Harris, Julie; Simmons, David; Rayman, Gerry; Temple, Rosemary; Dunger, David B.; Haidar, Ahmad; Nodale, Marianna; Wilinska, Malgorzata E.; Hovorka, Roman

    2011-01-01

    OBJECTIVE This study evaluated closed-loop insulin delivery with a model predictive control (MPC) algorithm during early (12–16 weeks) and late gestation (28–32 weeks) in pregnant women with type 1 diabetes. RESEARCH DESIGN AND METHODS Ten women with type 1 diabetes (age 31 years, diabetes duration 19 years, BMI 24.1 kg/m2, booking A1C 6.9%) were studied over 24 h during early (14.8 weeks) and late pregnancy (28.0 weeks). A nurse adjusted the basal insulin infusion rate from continuous glucose measurements (CGM), fed into the MPC algorithm every 15 min. Mean glucose and time spent in target (63–140 mg/dL), hyperglycemic (>140 to ≥180 mg/dL), and hypoglycemic (<63 to ≤50 mg/dL) were calculated using plasma and sensor glucose measurements. Linear mixed-effects models were used to compare glucose control during early and late gestation. RESULTS During closed-loop insulin delivery, median (interquartile range) plasma glucose levels were 117 (100.8–154.8) mg/dL in early and 126 (109.8–140.4) mg/dL in late gestation (P = 0.72). The overnight mean (interquartile range) plasma glucose time in target was 84% (50–100%) in early and 100% (94–100%) in late pregnancy (P = 0.09). Overnight mean (interquartile range) time spent hyperglycemic (>140 mg/dL) was 7% (0–40%) in early and 0% (0–6%) in late pregnancy (P = 0.25) and hypoglycemic (<63 mg/dL) was 0% (0–3%) and 0% (0–0%), respectively (P = 0.18). Postprandial glucose control, glucose variability, insulin infusion rates, and CGM sensor accuracy were no different in early or late pregnancy. CONCLUSIONS MPC algorithm performance was maintained throughout pregnancy, suggesting that overnight closed-loop insulin delivery could be used safely during pregnancy. More work is needed to achieve optimal postprandial glucose control. PMID:21216859

  1. Efficacy of an Overnight Predictive Low-Glucose Suspend System in Relation to Hypoglycemia Risk Factors in Youth and Adults With Type 1 Diabetes.

    PubMed

    Calhoun, Peter M; Buckingham, Bruce A; Maahs, David M; Hramiak, Irene; Wilson, Darrell M; Aye, Tandy; Clinton, Paula; Chase, Peter; Messer, Laurel; Kollman, Craig; Beck, Roy W; Lum, John

    2016-11-01

    We developed a system to suspend insulin pump delivery overnight when the glucose trend predicts hypoglycemia. This predictive low-glucose suspend (PLGS) system substantially reduces nocturnal hypoglycemia without an increase in morning ketosis. Evaluation of hypoglycemia risk factors that could potentially influence the efficacy of the system remains critical for understanding possible problems with the system and identifying patients that may have the greatest benefit when using the system. The at-home randomized trial consisted of 127 study participants with hemoglobin A1c (A1C) of ≤8.5% (mmol/mol) for patients aged 4-14 years and ≤8.0% for patient aged 15-45 years. Factors assessed included age, gender, A1C, diabetes duration, daily percentage basal insulin, total daily dose of insulin (units/kg-day), bedtime BG, bedtime snack, insulin on board, continuous glucose monitor (CGM) rate of change (ROC), day of the week, time system activated, daytime exercise intensity, and daytime CGM-measured hypoglycemia. The PLGS system was effective in preventing hypoglycemia for each factor subgroup. There was no evidence that the PLGS system was more or less effective in preventing hypoglycemia in any one subgroup compared with the other subgroups based on that factor. In addition, the effect of the system on overnight hyperglycemia did not differ in subgroups. The PLGS system tested in this study effectively reduced hypoglycemia without a meaningful increase in hyperglycemia across a variety of factors. © 2016 Diabetes Technology Society.

  2. Synthesis and characterization of insulin/zirconium phosphate@TiO2 hybrid composites for enhanced oral insulin delivery applications.

    PubMed

    Safari, Mostafa; Kamari, Younes; Ghiaci, Mehran; Sadeghi-Aliabadi, Hojjat; Mirian, Mina

    2017-05-01

    In this work, a series of composites of insulin (Ins)/zirconium phosphate (ZrP) were synthesized by intercalation method, then, these composites were coated with TiO 2 by sol-gel method to prepare Ins/ZrP@TiO 2 hybrid composites and the drug release of the composites was investigated by using UV-Vis spectroscopy. Ins/ZrP (10, 30, 60 wt%) composites were prepared by intercalation of insulin into the ZrP layers in water. Then Ins/ZrP composites were coated with different amounts of TiO 2 (30, 50, 100 wt %) by using titanium tetra n-butoxide, as precursor. Formation of intercalated Ins/ZrP and Ins/ZrP@TiO 2 hybrid composites was characterized by FT-IR, FE-SEM, BET and XRD analysis. Zeta potential of the optimized Ins/ZrP@TiO 2 hybrid composite was determined -27.2 mV. Cytotoxic effects of the optimized Ins/ZrP@TiO 2 hybrid composite against HeLa and Hek293T cell lines were evaluated using MTT assay and the results showed that designed drug delivery system was not toxic in biological environment. Compared to the Ins/ZrP composites, incorporation of TiO 2 coating enhanced the drug entrapment considerably, and reduced the drug release. The Ins/ZrP composites without TiO 2 coating released the whole drug after 30 min in pH 7.4 (phosphate buffer solution) while the TiO 2 -coated composites released the entrapped drug after 20 h. In addition to increasing the shelf life of hormone, this nanoencapsulation and nanocoating method can convert the insulin utilization from injection to oral and present a painless and more comfortable treatment for diabetics.

  3. Acute supplementation of amino acids increases net protein accretion in IUGR fetal sheep

    PubMed Central

    Rozance, Paul J.; Thorn, Stephanie R.; Friedman, Jacob E.; Hay, William W.

    2012-01-01

    Placental insufficiency decreases fetal amino acid uptake from the placenta, plasma insulin concentrations, and protein accretion, thus compromising normal fetal growth trajectory. We tested whether acute supplementation of amino acids or insulin into the fetus with intrauterine growth restriction (IUGR) would increase net fetal protein accretion rates. Late-gestation IUGR and control (CON) fetal sheep received acute, 3-h infusions of amino acids (with euinsulinemia), insulin (with euglycemia and euaminoacidemia), or saline. Fetal leucine metabolism was measured under steady-state conditions followed by a fetal muscle biopsy to quantify insulin signaling. In CON, increasing amino acid delivery rates to the fetus by 100% increased leucine oxidation rates by 100%. In IUGR, amino acid infusion completely suppressed fetal protein breakdown rates but increased leucine oxidation rate by only 25%, resulting in increased protein accretion rates by 150%. Acute insulin infusion, however, had very little effect on amino acid delivery rates, fetal leucine disposal rates, or fetal protein accretion rates in CON or IUGR fetuses despite robust signaling of the fetal skeletal muscle insulin-signaling cascade. These results indicate that, when amino acids are given directly into the fetal circulation independently of changes in insulin concentrations, IUGR fetal sheep have suppressed protein breakdown rates, thus increasing net fetal protein accretion. PMID:22649066

  4. Glycemic control and maternal and fetal outcomes in pregnant women with type 1 diabetes according to the type of basal insulin.

    PubMed

    Chico, A; Herranz, L; Corcoy, R; Ramírez, O; Goya, M M; Bellart, J; González-Romero, S; Codina, M; Sánchez, P; Cortázar, A; Acosta, D; Picón, M J; Rubio, J A; Megía, A; Sancho, M A; Balsells, M; Solá, E; González, N L; López-López, J

    2016-11-01

    To examine the potential role of the type of basal insulin on glycemic control and maternal and foetal outcomes in pregnant women with type 1 diabetes (T1DM). Retrospective cohort study of pregnancies attended at 18 Spanish tertiary hospitals. T1DM, singleton pregnancies, delivery between 2002-2010, and use of the same basal and prandial insulin from before pregnancy until delivery. A total of 1534 pregnancies were included. The basal insulin most commonly used was Neutral Protamine Hagedorn (NPH) (51.7%), followed by glargine (23.2%) and continuous subcutaneous insulin infusion (CSII) (21.1%). CSII users had longer diabetes duration. Multiple logistic regression analysis showed that CSII was independently associated with lower doses of insulin, higher glycated haemoglobin (HbA 1c ) in all trimesters, and higher rates of miscarriage, preterm birth and neonatal hypoglycemia. Glargine was related to a higher risk of preterm birth and a small-for-gestational age infant (SGA). The odds ratios (OR) of the associations between insulin type and clinical outcomes (from 0.642 to 4.894) have a relevant magnitude. In this observational study of pregnant women with T1DM, the type of basal insulin was independently associated with metabolic variables and foetal outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Nanoparticles Prepared From N,N-Dimethyl-N-Octyl Chitosan as the Novel Approach for Oral Delivery of Insulin: Preparation, Statistical Optimization and In-vitro Characterization

    PubMed Central

    Shamsa, Elnaz Sadat; Mahjub, Reza; Mansoorpour, Maryam; Rafiee-Tehrani, Morteza; Abedin Dorkoosh, Farid

    2018-01-01

    In this study, N,N-Dimethyl-N-Octyl chitosan was synthesized. Nanoparticles containing insulin were prepared using PEC method and were statistically optimized using the Box-Behnken response surface methodology. The independent factors were considered to be the insulin concentration, concentration and pH of the polymer solution, while the dependent factors were characterized as the size, zeta potential, PdI and entrapment efficiency. The optimized nanoparticles were morphologically studied using SEM. The cytotoxicity of the nanoparticles on the Caco-2 cell culture was studied using the MTT cytotoxicity assay method, while the permeation of the insulin nanoparticles across the Caco-2 cell monolayer was also determined. The optimized nanoparticles posed appropriate physicochemical properties. The SEM morphological studies showed spherical to sub-spherical nanoparticles with no sign of aggregation. The in-vitro release study showed that 95.5 ± 1.40% of the loaded insulin was released in 400 min. The permeability studies revealed significant enhancement in the insulin permeability using nanoparticles prepared from octyl chitosan at 240 min (11.3 ± 0.78%). The obtained data revealed that insulin nanoparticles prepared from N,N-Dimethyl-N-Octyl chitosan can be considered as the good candidate for oral delivery of insulin compared to nanoparticles prepared from N,N,N-trimethyl chitosan.

  6. Moving beyond subcutaneous insulin: the application of adjunctive therapies to the treatment of type 1 diabetes.

    PubMed

    Ang, Kathleen H; Sherr, Jennifer L

    2017-09-01

    With the discovery of insulin nearly a century ago, the diagnosis of Type 1 Diabetes (T1D) transformed from a death sentence to a chronic medical condition. Despite the advances that have been made, the vast majority of those living with T1D still struggle to achieve targeted control. Yet, a plethora of agents have been developed to treat those with Type 2 Diabetes. Exploration of how these agents may benefit those with T1D has been an area of intense investigation, especially due to the overweight/obesity epidemic, which now afflicts more than 60% of those living with T1D. Areas covered: This review focuses on agents that have been utilized, including inhaled insulin preparations, pramlintide, metformin, glucagon-like peptide-1 receptor agonists, dipeptidyl peptidase-4 inhibitors, sodium-glucose cotransporter-2 (SGLT-2) inhibitors, and dual SGLT1/2 inhibitors. Furthermore, with approval of the first hybrid closed loop (CL) system, the development of dual hormone CL systems is being explored. While the most common agent applied to these dual systems has been glucagon, research has been conducted to assess how some of the adjunctive therapies described above could aide with achieving postprandial glucose control while on CL insulin delivery. Expert opinion: By becoming less insulin-centric and incorporating some of these other agents, it is possible we may be able to better combat T1D.

  7. Oral delivery of bioencapsulated exendin-4 expressed in chloroplasts lowers blood glucose level in mice and stimulates insulin secretion in beta-TC6 cells

    PubMed Central

    Kwon, Kwang-Chul; Nityanandam, Ramya; New, James Stewart; Daniell, Henry

    2012-01-01

    Summary Glucagon like peptide (GLP-1) increases insulin secretion but is rapidly degraded (half-life: 2 min in circulation). GLP-1 analog, Exenatide (Byetta) has a longer half life (3.3–4 hrs) with potent insulinotropic effects but requires cold storage, daily abdominal injections with short shelf life. Because diabetic patients take >60,000 injections in their life time, alternative delivery methods are highly desired. Exenatide is ideal for oral delivery because insulinotropism is glucose dependent, with reduced risk of hypoglycemia even at higher doses. Therefore, exendin-4 (EX4) was expressed as a cholera toxin B subunit (CTB)-fusion protein in tobacco chloroplasts to facilitate bioencapsulation within plant cells and transmucosal delivery in the gut via GM1 receptors present in the intestinal epithelium. The transgene integration was confirmed by PCR and Southern blot analysis. Expression level of CTB-EX4 reached up to 14.3% of total leaf protein (TLP). Lyophilization of leaf material increased therapeutic protein concentration by 12–24 fold, extended their shelf life up to 15 months when stored at room temperature and eliminated microbes present in fresh leaves. The pentameric structure, disulfide bonds and functionality of CTB-EX4 were well preserved in lyophilized materials. Chloroplast derived CTB-EX4 showed increased insulin secretion similar to the commercial EX4 in beta-TC6, a mouse pancreatic cell line. Even when 5,000-fold excess dose of CTB-EX4 was orally delivered, it stimulated insulin secretion similar to the intraperitoneal injection of commercial EX4 but didn’t cause hypoglycemia in mice. Oral delivery of the bioencapsulated EX4 should eliminate injections, increase patient compliance/convenience and significantly lower their cost. PMID:23078126

  8. Bile Salt Stabilized Vesicles (Bilosomes): A Novel Nano-Pharmaceutical Design for Oral Delivery of Proteins and Peptides.

    PubMed

    Ahmad, Javed; Singhal, Madhur; Amin, Saima; Rizwanullah, Md; Akhter, Sohail; Kamal, Mohammad Amjad; Haider, Nafis; Midoux, Patrick; Pichon, Chantal

    2017-01-01

    With the advent of novel vesicular drug delivery systems especially bilosomes, for large molecular weight proteins and peptides, their oral administration seems a viable approach. These nano-vesicles have shown promising results for the effective delivery of insulin and other therapeutics, perhaps due to their structural composition. The present review has elaborated the biopharmaceutical challenges for the oral delivery of therapeutic proteins and peptides as well as presented a novel approach to deliver the essential macromolecules through oral route as bilosomes. The extensive search has been presented related to the formulation, evaluation and in vivo performance of bilosomes. Some of the crucial findings related to bilosomes have corroborated them superior to other colloidal carriers. The successful drug delivery through bilosomes requires significant justifications related to their interaction with the biological membranes. The other aspects such as absolute absorption, safety and toxicity of bilosome drug delivery should also be equally considered. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. pH-Sensitive stimulus-responsive nanocarriers for targeted delivery of therapeutic agents

    PubMed Central

    Karimi, Mahdi; Eslami, Masoud; Sahandi-Zangabad, Parham; Mirab, Fereshteh; Farajisafiloo, Negar; Shafaei, Zahra; Ghosh, Deepanjan; Bozorgomid, Mahnaz; Dashkhaneh, Fariba; Hamblin, Michael R.

    2016-01-01

    In recent years miscellaneous smart micro/nanosystems that respond to various exogenous/endogenous stimuli including temperature, magnetic/electric field, mechanical force, ultrasound/light irradiation, redox potentials, and biomolecule concentration have been developed for targeted delivery and release of encapsulated therapeutic agents such as drugs, genes, proteins, and metal ions specifically at their required site of action. Owing to physiological differences between malignant and normal cells, or between tumors and normal tissues, pH-sensitive nanosystems represent promising smart delivery vehicles for transport and delivery of anticancer agents. Furthermore, pH-sensitive systems possess applications in delivery of metal ions and biomolecules such as proteins, insulin, etc., as well as co-delivery of cargos, dual pH-sensitive nanocarriers, dual/multi stimuli-responsive nanosystems, and even in the search for new solutions for therapy of diseases such as Alzheimer’s. In order to design an optimized system, it is necessary to understand the various pH-responsive micro/nanoparticles and the different mechanisms of pH-sensitive drug release. This should be accompanied by an assessment of the theoretical and practical challenges in the design and use of these carriers. PMID:26762467

  10. Approaches for Enhancing Oral Bioavailability of Peptides and Proteins

    PubMed Central

    Renukuntla, Jwala; Vadlapudi, Aswani Dutt; Patel, Ashaben; Boddu, Sai HS.; Mitra, Ashim K

    2013-01-01

    Oral delivery of peptide and protein drugs faces immense challenge partially due to the gastrointestinal (GI) environment. In spite of considerable efforts by industrial and academic laboratories, no major breakthrough in the effective oral delivery of polypeptides and proteins has been accomplished. Upon oral administration, gastrointestinal epithelium acts as a physical and biochemical barrier for absorption of proteins resulting in low bioavailability (typically less than 1–2%). An ideal oral drug delivery system should be capable of a) maintaining the integrity of protein molecules until it reaches the site of absorption, b) releasing the drug at the target absorption site, where the delivery system appends to that site by virtue of specific interaction, and c) retaining inside the gastrointestinal tract irrespective of its transitory constraints. Various technologies have been explored to overcome the problems associated with the oral delivery of macromolecules such as insulin, gonadotropin-releasing hormones, calcitonin, human growth factor, vaccines, enkephalins, and interferons, all of which met with limited success. This review article intends to summarize the physiological barriers to oral delivery of peptides and proteins and novel pharmaceutical approaches to circumvent these barriers and enhance oral bioavailability of these macromolecules. PMID:23428883

  11. Effect of algorithm aggressiveness on the performance of the Hypoglycemia-Hyperglycemia Minimizer (HHM) System.

    PubMed

    Finan, Daniel A; McCann, Thomas W; Rhein, Kathleen; Dassau, Eyal; Breton, Marc D; Patek, Stephen D; Anhalt, Henry; Kovatchev, Boris P; Doyle, Francis J; Anderson, Stacey M; Zisser, Howard; Venugopalan, Ramakrishna

    2014-07-01

    The Hypoglycemia-Hyperglycemia Minimizer (HHM) System aims to mitigate glucose excursions by preemptively modulating insulin delivery based on continuous glucose monitor (CGM) measurements. The "aggressiveness factor" is a key parameter in the HHM System algorithm, affecting how readily the system adjusts insulin infusion in response to changing CGM levels. Twenty adults with type 1 diabetes were studied in closed-loop in a clinical research center for approximately 26 hours. This analysis focused on the effect of the aggressiveness factor on the insulin dosing characteristics of the algorithm and, to a lesser extent, on the glucose control results observed. As the aggressiveness factor increased from conservative to medium to aggressive: the maximum observed insulin dose delivered by the algorithm—which is designed to give doses that are corrective in nature every 5 minutes—increased (1.00 vs 1.15 vs 2.20 U, respectively); tendency to adhere to the subject's nominal basal dose decreased (61.9% vs 56.6% vs 53.4%); and readiness to decrease insulin below basal also increased (18.4% vs 19.4% vs 25.2%). Glucose analyses by both CGM and Yellow Springs Instruments (YSI) indicated that the aggressive setting of the algorithm resulted in the least time spent at levels >180 mg/dL, and the most time spent between 70-180 mg/dL. There was no severe hyperglycemia, diabetic ketoacidosis, or severe hypoglycemia for any of the aggressiveness values investigated. These analyses underscore the importance of investigating the sensitivity of the HHM System to its key parameters, such as the aggressiveness factor, to guide future development decisions. © 2014 Diabetes Technology Society.

  12. Mucosal delivery of liposome-chitosan nanoparticle complexes.

    PubMed

    Carvalho, Edison L S; Grenha, Ana; Remuñán-López, Carmen; Alonso, Maria José; Seijo, Begoña

    2009-01-01

    Designing adequate drug carriers has long been a major challenge for those working in drug delivery. Since drug delivery strategies have evolved for mucosal delivery as the outstanding alternative to parenteral administration, many new drug delivery systems have been developed which evidence promising properties to address specific issues. Colloidal carriers, such as nanoparticles and liposomes, have been referred to as the most valuable approaches, but still have some limitations that can become more inconvenient as a function of the specific characteristics of administration routes. To overcome these limitations, we developed a new drug delivery system that results from the combination of chitosan nanoparticles and liposomes, in an approach of combining their advantages, while avoiding their individual limitations. These lipid/chitosan nanoparticle complexes are, thus, expected to protect the encapsulated drug from harsh environmental conditions, while concomitantly providing its controlled release. To prepare these assemblies, two different strategies have been applied: one focusing on the simple hydration of a previously formed dry lipid film with a suspension of chitosan nanoparticles, and the other relying on the lyophilization of both basic structures (nanoparticles and liposomes) with a subsequent step of hydration with water. The developed systems are able to provide a controlled release of the encapsulated model peptide, insulin, evidencing release profiles that are dependent on their lipid composition. Moreover, satisfactory in vivo results have been obtained, confirming the potential of these newly developed drug delivery systems as drug carriers through distinct mucosal routes.

  13. Effect of flow rate and insulin priming on the recovery of insulin from microbore infusion tubing.

    PubMed

    Fuloria, M; Friedberg, M A; DuRant, R H; Aschner, J L

    1998-12-01

    A retrospective medical record review of 13 consecutive, hyperglycemic, extremely low birth weight (ELBW) infants treated with continuous insulin infusions revealed a 14- to 24-hour delay (mean, 19 hours) in blood glucose normalization despite stepwise increases in insulin infusion rates. This in vitro study examined the effects of flow rate and insulin priming on insulin recovery from polyvinyl chloride (PVC) tubing and polyethylene (PE)-lined PVC tubing infused with a standard insulin stock solution. Stock insulin solution (0.2 U/mL) was infused through microbore PVC or PE-lined tubing at flow rates of 0.05 and 0.2 mL/h. To determine if saturation of nonspecific binding sites would alter effluent insulin concentration, we compared insulin recovery from tubing previously flushed with the stock solution and tubing primed with 5 U/mL of insulin for 20 minutes. Effluent samples, which were collected at baseline and at six time points during a 24-hour period, were immediately frozen at -20 degreesC. Insulin concentration was measured by IMx immunoassay. Data were analyzed using general linear modeling with repeated measures. At 0.05 mL/h flow rate, insulin recovery from unprimed PVC tubing at 1, 2, 4, and 8 hours was 17%, 11%, 27%, and 55%, respectively, with 100% recovery at 24 hours. From insulin-primed tubing, insulin recovery was approximately 70% at 1, 2, and 4 hours, and close to 100% at 8 hours. At a faster flow rate of 0.2 mL/h, insulin recovery at 1, 2, 4, and 8 hours was 22%, 38%, 67%, and 75% vs 42%, 85%, 91% and 95% from unprimed and insulin-primed PVC tubing, respectively. Similar results were obtained from unprimed and insulin-primed PE-lined tubing at 0.2 mL/h flow rate. Priming of microbore tubing with 5 U/mL of insulin solution for 20 minutes to block nonspecific binding sites enhances delivery of a standard insulin stock at infusion rates typically used to treat hyperglycemic ELBW infants. We conclude that priming the tubing with a higher concentration of insulin before initiation of standard insulin infusion therapy should accelerate achievement of steady-state insulin delivery and correction of hyperglycemia in ELBW infants.

  14. Membrane Cholesterol in Skeletal Muscle: A Novel Player in Excitation-Contraction Coupling and Insulin Resistance

    PubMed Central

    Barrientos, G.; Sánchez-Aguilera, P.; Jaimovich, E.; Hidalgo, C.

    2017-01-01

    Membrane cholesterol is critical for signaling processes in a variety of tissues. We will address here current evidence supporting an emerging role of cholesterol on excitation-contraction coupling and glucose transport in skeletal muscle. We have centered our review on the transverse tubule system, a complex network of narrow plasma membrane invaginations that propagate membrane depolarization into the fiber interior and allow nutrient delivery into the fibers. We will discuss current evidence showing that transverse tubule membranes have remarkably high cholesterol levels and we will address how modifications of cholesterol content influence excitation-contraction coupling. In addition, we will discuss how membrane cholesterol levels affect glucose transport by modulating the insertion into the membrane of the main insulin-sensitive glucose transporter GLUT4. Finally, we will address how the increased membrane cholesterol levels displayed by obese animals, which also present insulin resistance, affect these two particular skeletal muscle functions. PMID:28367451

  15. Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

    PubMed

    Hanazaki, Kazuhiro; Munekage, Masaya; Kitagawa, Hiroyuki; Yatabe, Tomoaki; Munekage, Eri; Shiga, Mai; Maeda, Hiromichi; Namikawa, Tsutomu

    2016-09-01

    The incidence of diabetes is increasing at an unprecedented pace and has become a serious health concern worldwide during the last two decades. Despite this, adequate glycemic control using an artificial pancreas has not been established, although the 21st century has seen rapid developments in this area. Herein, we review current topics in glycemic control for both the wearable artificial pancreas for type 1 and type 2 diabetic patients and the bedside artificial pancreas for surgical diabetic patients. In type 1 diabetic patients, nocturnal hypoglycemia associated with insulin therapy remains a serious problem that could be addressed by the recent development of a wearable artificial pancreas. This smart phone-like device, comprising a real-time, continuous glucose monitoring system and insulin pump system, could potentially significantly reduce nocturnal hypoglycemia compared with conventional glycemic control. Of particular interest in this space are the recent inventions of a low-glucose suspend feature in the portable systems that automatically stops insulin delivery 2 h following a glucose sensor value <70 mg/dL and a bio-hormonal pump system consisting of insulin and glucagon pumps. Perioperative tight glycemic control using a bedside artificial pancreas with the closed-loop system has also proved safe and effective for not only avoiding hypoglycemia, but also for reducing blood glucose level variability resulting in good surgical outcomes. We hope that a more sophisticated artificial pancreas with closed-loop system will now be taken up for routine use worldwide, providing enormous relief for patients suffering from uncontrolled hyperglycemia, hypoglycemia, and/or variability in blood glucose concentrations.

  16. An integrated buccal delivery system combining chitosan films impregnated with peptide loaded PEG-b-PLA nanoparticles.

    PubMed

    Giovino, Concetta; Ayensu, Isaac; Tetteh, John; Boateng, Joshua S

    2013-12-01

    Peptide (insulin) loaded nanoparticles (NPs) have been embedded into buccal chitosan films (Ch-films-NPs). These films were produced by solvent casting and involved incorporating in chitosan gel (1.25% w/v), NPs-Insulin suspensions at three different concentrations (1, 3, and 5mg of NPs per film) using glycerol as plasticiser. Film swelling and mucoadhesion were investigated using 0.01M PBS at 37°C and texture analyzer, respectively. Formulations containing 3mg of NPs per film produced optimised films with excellent mucoadhesion and swelling properties. Dynamic laser scattering measurements showed that the erosion of the chitosan backbone controlled the release of NPs from the films, preceding in vitro drug (insulin) release from Ch-films-NPs after 6h. Modulated release was observed with 70% of encapsulated insulin released after 360h. The use of chitosan films yielded a 1.8-fold enhancement of ex vivo insulin permeation via EpiOral™ buccal tissue construct relative to the pure drug. Flux and apparent permeation coefficient of 0.1μg/cm(2)/h and 4×10(-2)cm(2)/h were respectively obtained for insulin released from Ch-films-NPs-3. Circular dichroism and FTIR spectroscopy demonstrated that the conformational structure of the model peptide drug (insulin) released from Ch-films-NPs was preserved during the formulation process. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Application of Ultrasound Energy as a New Drug Delivery System

    NASA Astrophysics Data System (ADS)

    Tachibana, Katsuro; Tachibana, Shunro

    1999-05-01

    Ultrasound has been in use for the last three decades as amodality for diagnostic imaging in medicine. Recently, there have beennumerous reports on the application of nonthermal ultrasound energyfor targeting or controlling drug release. This new concept oftherapeutic ultrasound combined with drugs has led to much excitementin various medical fields. Ultrasound energy can enhance the effectsof thrombolytic agents such as urokinase. Therapeutic ultrasoundcatheters are currently being developed for treatment ofcardiovascular diseases. Devices with ultrasound transducers implantedin transdermal drug patches are also being evaluated for possibledelivery of insulin through the skin. Chemical activation of drugs byultrasound energy for treatment of cancers is another new fieldrecently termed “Sonodynamic Therapy”. Various examples of ultrasoundapplication are under investigation which could lead to revolutionarydrug delivery systems in the future.

  18. Preparation, properties and biological application of pH-sensitive poly(ethylene oxide) (PEO) hydrogels grafted with acrylic acid(AAc) using gamma-ray irradiation

    NASA Astrophysics Data System (ADS)

    Nho, Young Chang; Mook Lim, Youn; Moo Lee, Young

    2004-09-01

    pH-sensitive hydrogels were studied as a drug carrier for the protection of insulin from the acidic environment of the stomach before releasing it in the small intestine. In this study, hydrogels based on poly(ethylene oxide) (PEO) networks grafted with acrylic acid (AAc) were prepared via a two-step process. PEO hydrogels were prepared by γ-ray irradiation, and then grafting by AAc monomer onto the PEO hydrogels with the subsequent irradiation (radiation dose: 5-20 kGy, dose rate: 2.15 kGy/h). These grafted hydrogels showed a pH-sensitive swelling behavior. The grafted hydrogels were used as a carrier for the drug delivery systems for the controlled release of insulin. The in vitro drug release behaviors of these hydrogels were examined by quantification analysis with a UV/VIS spectrophotometer. Insulin was loaded into freeze-dried hydrogels (7 mm×3 mm×2.5 mm) and administrated orally to healthy and diabetic Wistar rats. The oral administration of insulin-loaded hydrogels to Wistar rats decreased the blood glucose levels obviously for at least 4 h due to the absorption of insulin in the gastrointestinal tract.

  19. VB12-coated Gel-Core-SLN containing insulin: Another way to improve oral absorption.

    PubMed

    He, Haibing; Wang, Puxiu; Cai, Cuifang; Yang, Rui; Tang, Xing

    2015-09-30

    To improve the oral absorption of insulin, a novel carrier of Vitamin B12 (VB12) gel core solid lipid nanopaticles (Gel-Core-SLN, GCSLN) was designed with a gel core, lipid matrix and VB12-coated surface. VB12-stearate was synthesized and characterized by infrared spectroscopy (IR), nuclear magnetic resonance spectroscopy (NMR) and mass spectrometry (MS). Sol-gel conversion following ultrasonic heating and double emulsion technology were combined to implant the insulin-containing gel into solid lipid nanoparticles (SLN). The influence of the mode of administration, food, the amount of VB12-stearate and the particle size on the oral absorption of insulin incorporated in the VB12-GCSLN was investigated. The determined partition coefficient (LogP) of VB12-stearate in a dichloromethane (DCM)-water system was 3.4. This new structure of VB12-GCSLN had higher insulin encapsulation efficiency (EE) of 55.9%, a lower burst release of less than 10% in the first 2h. In vivo studies demonstrated that stronger absorption of insulin with a relative pharmacological availability (PA) of 9.31% compared with the normal insulin-loaded SLN and GCSLN and fairly stable blood glucose levels up to 12h were maintained without any sharp fluctuations. This study suggests that VB12-GCSLN containing insulin appears to be a promising nano carrier for oral delivery of biomacromolecules with relatively high pharmacological availability. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. RN Diabetes Virtual Case Management: A New Model for Providing Chronic Care Management.

    PubMed

    Brown, Nancy N; Carrara, Barbara E; Watts, Sharon A; Lucatorto, Michelle A

    2016-01-01

    The U.S. chronic disease health care system has substantial gaps in delivery of services. New models of care change traditional delivery of care and explore new settings for care. This article describes a new model of diabetes chronic care delivery: nurse-delivered care that includes protocol-based insulin titration and patient education delivered solely in a virtual environment. In phase 1, the clinical outcome of time to achievement of glycated hemoglobin (A(1C)) goals (P < .001; 95% confidence interval, 1.68-2.24) was significantly improved by registered nurse (RN) standing order intervention (n = 24) as compared with historical controls (n = 28). In phase 2, patients who were referred to an RN-managed insulin titration protocol with individualized A(1C) goals had a significant (P < .001; 95% confidence interval, 1.680-2.242) reduction in results from a mean of 9.6% at baseline to 7.7% at completion. Average patient age was 66 years, with a mean duration of 11 years diagnosed with diabetes. Safety was demonstrated by the absence of hypoglycemia related to RN protocol adjustment. There were no admissions or emergency room (ER) visits for hypoglycemia. This study demonstrates safety and efficacy of RN virtual chronic disease management for an older population of patients with long-standing diabetes.

  1. Gestational Protein Restriction Impairs Glucose Disposal in the Gastrocnemius Muscles of Female Rats

    PubMed Central

    Blesson, Chellakkan S.; Chinnathambi, Vijayakumar; Kumar, Sathish

    2017-01-01

    Gestational low-protein (LP) diet causes hyperglycemia and insulin resistance in adult offspring, but the mechanism is not clearly understood. In this study, we explored the role of insulin signaling in gastrocnemius muscles of gestational LP-exposed female offspring. Pregnant rats were fed a control (20% protein) or an isocaloric LP (6%) diet from gestational day 4 until delivery. Normal diet was given to mothers after delivery and to pups after weaning until necropsy. Offspring were euthanized at 4 months, and gastrocnemius muscles were treated with insulin ex vivo for 30 minutes. Messenger RNA and protein levels of molecules involved in insulin signaling were assessed at 4 months. LP females were smaller at birth but showed rapid catchup growth by 4 weeks. Glucose tolerance test in LP offspring at 3 months showed elevated serum glucose levels (P < 0.01; glycemia Δ area under the curve 342 ± 28 in LP vs 155 ± 23 in controls, mmol/L * 120 minutes) without any change in insulin levels. In gastrocnemius muscles, LP rats showed reduced tyrosine phosphorylation of insulin receptor substrate 1 upon insulin stimulation due to the overexpression of tyrosine phosphatase SHP-2, but serine phosphorylation was unaffected. Furthermore, insulin-induced phosphorylation of Akt, glycogen synthase kinase (GSK)–3α, and GSK-3β was diminished in LP rats, and they displayed an increased basal phosphorylation (inactive form) of glycogen synthase. Our study shows that gestational protein restriction causes peripheral insulin resistance by a series of phosphorylation defects in skeletal muscle in a mechanism involving insulin receptor substrate 1, SHP-2, Akt, GSK-3, and glycogen synthase causing dysfunctional GSK-3 signaling and increased stored glycogen, leading to distorted glucose homeostasis. PMID:28324067

  2. Oral insulin delivery by means of solid lipid nanoparticles

    PubMed Central

    Sarmento, Bruno; Martins, Susana; Ferreira, Domingos; Souto, Eliana B

    2007-01-01

    The aim of this work was to produce and characterize cetyl palmitate-based solid lipid nanoparticles (SLN) containing insulin, and to evaluate the potential of these colloidal carriers for oral administration. SLN were prepared by a modified solvent emulsification-evaporation method based on a w/o/w double emulsion. The particle size, zeta potential and association efficiency of unloaded and insulin-loaded SLN were determined and were found to be around 350 nm, negatively charged and the insulin association efficiency was over 43%. After oral administration of insulin-loaded SLN to diabetic rats, a considerable hypoglycemic effect was observed during 24 hours. These results demonstrated that SLN promote the oral absorption of insulin. PMID:18203440

  3. Kinetics of insulin aggregation in aqueous solutions upon agitation in the presence of hydrophobic surfaces.

    PubMed Central

    Sluzky, V; Tamada, J A; Klibanov, A M; Langer, R

    1991-01-01

    The stability of protein-based pharmaceuticals (e.g., insulin) is important for their production, storage, and delivery. To gain an understanding of insulin's aggregation mechanism in aqueous solutions, the effects of agitation rate, interfacial interactions, and insulin concentration on the overall aggregation rate were examined. Ultraviolet absorption spectroscopy, high-performance liquid chromatography, and quasielastic light scattering analyses were used to monitor the aggregation reaction and identify intermediate species. The reaction proceeded in two stages; insulin stability was enhanced at higher concentration. Mathematical modeling of proposed kinetic schemes was employed to identify possible reaction pathways and to explain greater stability at higher insulin concentration. Images PMID:1946348

  4. Analysis of glucose responses to automated insulin suspension with sensor-augmented pump therapy.

    PubMed

    Ly, Trang T; Nicholas, Jennifer A; Retterath, Adam; Davis, Elizabeth A; Jones, Timothy W

    2012-07-01

    The advent of sensor-augmented pump therapy with a low-glucose suspend (LGS) function (Medtronic Paradigm Veo System), allowing insulin to be automatically suspended for up to 2 h when sensor glucose falls below a preset threshold, has the potential to reduce the duration of hypoglycemia. In this article, we analyzed blood glucose profiles following a full 2-h insulin suspension activated by the LGS function, as well as examined different patterns of use among patients. Data from a cohort of participants using the Veo System for up to 6 months were analyzed to determine the time and duration of insulin suspension activated by the LGS function. We further evaluated overnight suspend events with no patient response occurring prior to 3:00 a.m., which allowed us to determine the pattern of sensor glucose values with no patient intervention during and after the period of insulin suspension. There were 3,128 LGS events during the 2,493 days evaluated. The median duration was 11.2 min, and 36% of events occurred overnight. There were 126 full 2-h suspend events that occurred overnight with no patient response, occurring before 3:00 a.m. For these events, the mean sensor glucose at the end of the 2-h suspend period was 99 ± 6 mg/dL ([means ± SE] 5.5 ± 0.3 mmol/L). The mean sensor glucose 2 h after insulin delivery resumed was 155 ± 10 mg/dL (8.6 ± 0.6 mmol/L). There were no episodes of severe hypoglycemia or diabetic ketoacidosis. Analyses of sensor glucose patterns following insulin suspension activated by LGS suggest that this technology is safe and unlikely to be associated with adverse outcomes.

  5. Simultaneous Effect of Thiolation and Carboxylation of Chitosan Particles Towards Mucoadhesive Oral Insulin Delivery Applications: An In Vitro and In Vivo Evaluation.

    PubMed

    Rekha, M R; Sharma, Chandra P

    2015-01-01

    Thiomalyl chitosan (TCS), a pH sensitive thiolated chitosan derivative, was developed and investigated towards oral protein delivery application. Particles of z-average 364 ± 5.6 nm with a negative zeta potential of 14.4 mV was obtained by tripolyphosphate cross linking of TCS. The release of insulin from TCS particles was significantly restricted at pH 1.2 minimizing up to about < 10% in 3 hours. The permeation enhancement ratio was found to 13 times higher than the FD4 alone and was 1.6 times higher than the unmodified chitosan particles. The protein protective properties of the matrix were established in presence of pepsin and pancreatic enzymes. Confocal microscopy studies proved the tight junction opening of Caco-2 cells by these thiolated chitosan particles and the in vivo studies on diabetic rats established its potential towards oral peptide delivery with pharmacological availability (PA) of 1.5%. The significance of this work is to establish that, the presence of multiple functional groups having similar property in the same matrix can improve its suitability as a promising candidate for oral peptide delivery with improved release characteristics, mucoadhesion as well as protecting the insulin activity and enhancing the permeability across the intestinal wall.

  6. From the Cover: Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies

    NASA Astrophysics Data System (ADS)

    McAllister, Devin V.; Wang, Ping M.; Davis, Shawn P.; Park, Jung-Hwan; Canatella, Paul J.; Allen, Mark G.; Prausnitz, Mark R.

    2003-11-01

    Arrays of micrometer-scale needles could be used to deliver drugs, proteins, and particles across skin in a minimally invasive manner. We therefore developed microfabrication techniques for silicon, metal, and biodegradable polymer microneedle arrays having solid and hollow bores with tapered and beveled tips and feature sizes from 1 to 1,000 μm. When solid microneedles were used, skin permeability was increased in vitro by orders of magnitude for macromolecules and particles up to 50 nm in radius. Intracellular delivery of molecules into viable cells was also achieved with high efficiency. Hollow microneedles permitted flow of microliter quantities into skin in vivo, including microinjection of insulin to reduce blood glucose levels in diabetic rats. transdermal drug delivery | skin | microelectromechanical systems | solid microneedle | hollow needle injection

  7. The automatic regulation of the basal dose on the insulin pump for the treatment of patients that have diabetes type 1

    PubMed Central

    Mehanović, Sifet; Mujić, Midhat

    2010-01-01

    Diabetes mellitus type 1 is a chronic metabolic disorder, and its main characteristic is Hyperglycemia. It usually occurs in the early years because of the absolute or relative absence of the active insulin that is caused by the autoimmune disease of the β cells of the pancreas. Despite the numerous researches and efforts of the scientists, the therapy for Diabetes type 1 is based on the substitution of insulin. Even though the principles of the therapy have not changed so much, still some important changes have occurred in the production and usage of insulin. Lately, the insulin pumps are more frequent in the therapy for Diabetes type 1. The functioning of the pump is based on the continuing delivery of insulin in a small dose (“the basal dose”), that keeps the level of glycemia in the blood constant. The increase of glycemia during the meal is reduced with the additional dose of insulin (“the bolus dose”). The use of the insulin pumps and the continuing glucose sensors has provided an easier and more efficient monitoring of the diabetes, a better metabolic control and a better life quality for the patient and his/her family. This work presents the way of automatic regulation of the basal dose of insulin through the synthesis of the functions of the insulin pump and the continuing glucose sensor. The aim is to give a contribution to the development of the controlling algorithm on the insulin pump for the automatic regulation of the glucose concentration in the blood. This could be a step further which is closer to the delivery of the dose of insulin that is really needed for the basic needs of the organism, and a significant contribution is given to the development of the artificial pancreas. PMID:20507288

  8. The automatic regulation of the basal dose on the insulin pump for the treatment of patients that have Diabetes type 1.

    PubMed

    Mehanović, Sifet; Mujić, Midhat

    2010-05-01

    Diabetes mellitus type 1 is a chronic metabolic disorder, and its main characteristic is Hyperglycemia. It usually occurs in the early years because of the absolute or relative absence of the active insulin that is caused by the autoimmune disease of the beta cells of the pancreas. Despite the numerous researches and efforts of the scientists, the therapy for Diabetes type 1 is based on the substitution of insulin. Even though the principles of the therapy have not changed so much, still some important changes have occurred in the production and usage of insulin. Lately, the insulin pumps are more frequent in the therapy for Diabetes type 1. The functioning of the pump is based on the continuing delivery of insulin in a small dose ("the basal dose"), that keeps the level of glycemia in the blood constant. The increase of glycemia during the meal is reduced with the additional dose of insulin ("the bolus dose"). The use of the insulin pumps and the continuing glucose sensors has provided an easier and more efficient monitoring of the diabetes, a better metabolic control and a better life quality for the patient and his/her family. This work presents the way of automatic regulation of the basal dose of insulin through the synthesis of the functions of the insulin pump and the continuing glucose sensor. The aim is to give a contribution to the development of the controlling algorithm on the insulin pump for the automatic regulation of the glucose concentration in the blood. This could be a step further which is closer to the delivery of the dose of insulin that is really needed for the basic needs of the organism, and a significant contribution is given to the development of the artificial pancreas.

  9. Insulin analogues with improved absorption characteristics.

    PubMed

    Brange, J; Hansen, J F; Langkjaer, L; Markussen, J; Ribel, U; Sørensen, A R

    1992-01-01

    The insulin preparations available today are not ideal for therapy as s.c. injection does not provide a physiological insulin profile. With the aim to improve the absorption properties recombinant DNA technology has been utilized to design novel insulin molecules with changed physico-chemical characteristics and hence altered subcutaneous absorption kinetics. Soluble, long-acting human insulin analogues in which the isoelectric point has been increased from 5.4 to approx. 7 are absorbed very slowly, providing a more constant basal insulin delivery with lower day-to-day variation than present protracted preparations. In addition they have better storage stability. Rapid-acting human insulin analogues with largely reduced self-association are absorbed substantially faster from subcutaneous tissue than current regular insulin and thus are better suited for bolus injection. The absorption kinetics of these analogues have been able to explain the mechanism behind the dose effect on insulin absorption rate.

  10. Progress of artificial pancreas devices towards clinical use: the first outpatient studies.

    PubMed

    Russell, Steven J

    2015-04-01

    This article describes recent progress in the automated control of glycemia in type 1 diabetes with artificial pancreas devices that combine continuous glucose monitoring with automated decision-making and insulin delivery. After a gestation period of closely supervised feasibility studies in research centers, the last 2 years have seen publication of studies testing these devices in outpatient environments, and many more such studies are ongoing. The most basic form of automation, suspension of insulin delivery for actual or predicted hypoglycemia, has been shown to be effective and well tolerated, and a first-generation device has actually reached the market. Artificial pancreas devices that actively dose insulin fall into two categories, those that dose insulin alone and those that also use glucagon to prevent and treat hypoglycemia (bihormonal artificial pancreas). Initial outpatient clinical trials have shown that both strategies can improve glycemic management in comparison with patient-controlled insulin pump therapy, but only the bihormonal strategy has been tested without restrictions on exercise. Artificial pancreas technology has the potential to reduce acute and chronic complications of diabetes and mitigate the burden of diabetes self-management. Successful outpatient studies bring these technologies one step closer to availability for patients.

  11. Long-term Effect of Biomineralized Insulin Nanoparticles on Type 2 Diabetes Treatment

    PubMed Central

    Xiao, Yun; Wang, Xiaoyu; Wang, Ben; Liu, Xueyao; Xu, Xurong; Tang, Ruikang

    2017-01-01

    Intracellular insulin may exhibit a long-term effect in regulating protein synthesis, DNA synthesis, and gene transcription. However, the intracellular delivery of insulin is a great challenge. Here, we describe how a simple biomineralization modification of insulin can transport it into intact cells on a large scale, leading to a long-term therapeutic effect on diabetes mellitus. Using insulin-resistant HepG2 cell and diabetic KKAy mice as models, in vitro and in vivo assessments have demonstrated that biomineralized insulin nanoparticles can trigger glucose metabolism, and this improvement extends after the treatment. The potential exists to improve the current treatment of type 2 diabetes mellitus through biomineralized modifications of insulin. This study provides a new paradigm of biomimetic nanotechnology for biomedical applications. PMID:29158827

  12. Tolerogenic insulin peptide therapy precipitates type 1 diabetes.

    PubMed

    Bergman, Marie-Louise; Lopes-Carvalho, Thiago; Martins, Ana-Catarina; Grieco, Fabio A; Eizirik, Décio L; Demengeot, Jocelyne

    2017-07-03

    Daniel et al. (https://doi.org/10.1084/jem.20110574) have previously published in JEM a study on the preventive effect of tolerogenic vaccination with a strong agonist insulin mimetope in type 1 diabetes. Our study now challenges these results and shows that osmotic pump delivery of the modified insulin peptide R22E did not prevent hyperglycemia, accelerated disease onset, increased its incidence, and worsened insulitis. © 2017 Bergman et al.

  13. Effect of different intestinal conditions on the intermolecular interaction between insulin and cell-penetrating peptide penetratin and on its contribution to stimulation of permeation through intestinal epithelium.

    PubMed

    Kamei, Noriyasu; Aoyama, Yukina; Khafagy, El-Sayed; Henmi, Mao; Takeda-Morishita, Mariko

    2015-08-01

    Our recent studies have shown that the coadministration of cell-penetrating peptides (CPPs) is a potential strategy for oral delivery of peptide- and protein-based biopharmaceuticals. The intermolecular interaction between drug and CPP is an essential factor in the effective delivery of these drugs, but the characteristics of the interaction under the conditions of the intestinal lumen remain unknown. In this study, therefore, we examined the characteristics of binding of the amphipathic CPP penetratin to insulin and the efficiency of its enhancement of epithelial insulin transport at different pH and in simulated intestinal fluids (SIFs). The binding between insulin and penetratin was pH dependent and particularly decreased at pH 5.0. In addition, we clarified that the sodium taurocholate (NaTC) present in two types of SIF (fasted-state SIF [FaSSIF] and fed-state SIF [FeSSIF]) affected binding efficiency. However, the permeation of insulin through a Caco-2 cell monolayer was significantly facilitated by coincubation with l- or d-penetratin at various pH values. Moreover, the permeation-stimulating effect of l-penetratin was observed in FaSSIF containing NaTC and lecithin, but not in 3mM NaTC solution, suggesting that the presence of lecithin was the key factor in maintaining the ability of penetratin to enhance the intestinal absorption of biopharmaceuticals. This report describes the essential considerations for in vivo use and clinical application of a CPP-based oral delivery strategy. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Minimizing morbidity of hypoglycemia in diabetes: A review of mini-dose glucagon

    USDA-ARS?s Scientific Manuscript database

    Type 1 diabetes is a common chronic disease of childhood and one of the most difficult conditions to manage. Advances in insulin formulations and insulin delivery devices have markedly improved the ability to achieve normal glucose homeostasis. However, hypoglycemia remains the primary limiting fact...

  15. Part-2: Analytical Expressions of Concentrations of Glucose, Oxygen, and Gluconic Acid in a Composite Membrane for Closed-Loop Insulin Delivery for the Non-steady State Conditions.

    PubMed

    Mehala, N; Rajendran, L; Meena, V

    2017-02-01

    A mathematical model developed by Abdekhodaie and Wu (J Membr Sci 335:21-31, 2009), which describes a dynamic process involving an enzymatic reaction and diffusion of reactants and product inside glucose-sensitive composite membrane has been discussed. This theoretical model depicts a system of non-linear non-steady state reaction diffusion equations. These equations have been solved using new approach of homotopy perturbation method and analytical solutions pertaining to the concentrations of glucose, oxygen, and gluconic acid are derived. These analytical results are compared with the numerical results, and limiting case results for steady state conditions and a good agreement is observed. The influence of various kinetic parameters involved in the model has been presented graphically. Theoretical evaluation of the kinetic parameters like the maximal reaction velocity (V max ) and Michaelis-Menten constants for glucose and oxygen (K g and K ox ) is also reported. This predicted model is very much useful for designing the glucose-responsive composite membranes for closed-loop insulin delivery.

  16. Multicenter User Evaluation of ACCU-CHEK® Combo, an Integrated System for Continuous Subcutaneous Insulin Infusion

    PubMed Central

    Kerr, David; Hoogma, Roel P.L.M; Buhr, Andreas; Petersen, Bettina; Storms, Fred E.M.G

    2010-01-01

    Background The aim of this study was to evaluate a newly developed system for insulin delivery incorporating a multifunctional blood glucose meter and a remotely controlled insulin pump (ACCU-CHEK® Combo system) in established pump users with type 1 diabetes. The technology was assessed both from device performance and subject usability perspectives. Method A multicenter, prospective, single group study was carried out in five centers in the Netherlands and four centers in the United Kingdom for more than 6 months. The study was divided into two phases: Phase 1 (4 weeks) for device validation purposes and phase 2 (22 weeks) to observe the impact of the system on metabolic control, patient satisfaction [using the Diabetes Treatment Satisfaction Questionnaire (DTSQ)] and device safety. Results Eighty subjects completed the planned study period. There were no unexpected device errors. Treatment satisfaction was high at baseline and further increased to study end (DTSQ change version: sum score, 10.6 ± 7.2; scale score range, -18 to +18, p < 0.0001). Hemoglobin A1c improved continuously over time, from 7.9% (±0.9%) to 7.7% (±0.8%) at month 3 (p < 0.001) and 7.6% (±0.8%) at month 6 (p < 0.0001). The frequency of severe hypoglycemia was 0.08 per patient years. There was no case of ketoacidosis. Conclusions The new system was evaluated by experienced continuous subcutaneous insulin infusion users as safe in daily practice and associated with favorable treatment satisfaction and a modest improvement in glycemic control. PMID:21129336

  17. Insulin Pen—The “iPod” for Insulin Delivery (Why Pen Wins over Syringe)

    PubMed Central

    Asamoah, Ernest

    2008-01-01

    Diabetes affects most aspects of everyday life and places considerable responsibility on the patient; therefore, without patient acceptance of what we offer, the therapy is unlikely to be adhered to especially when that therapy happens to be insulin injection. In 2008, almost every physician/health care provider carries new and sleek cell phones (because the newer ones are well designed and function better). Why these same providers continue to prescribe insulin via syringes in 2008 is something that I cannot fathom. Previously, some insurance companies only paid for vials and there was no other choice, but today almost all insurance pay for pens and so the “insurance reason” is no longer tenable. Since Banting and Best discovered insulin in 1921, scientists have continued to improve the types of insulin (making them mimic physiology more closely in order to minimize hypoglycemia and improve glycemic control as seen with the latest analog insulins). In the same manner, the delivery process of insulin has also continued to evolve to make it easier and more acceptable to patients. Studies have shown that patients prefer device use over traditional vials/syringes. Pen devices used to inject insulin lead to better compliance, are quicker to inject, dosing is much more accurate, and, surprisingly, are more cost effective. I challenge my colleagues to take full responsibility for what their patients use. If a provider believes in pen devices, most of his/her patients will use them. The products your patients use is a direct reflection of what you practice. Educating providers to change their beliefs and practices is key to moving American diabetic patients from syringes to pen devices. PMID:19885358

  18. Insulin pen-the "iPod" for insulin delivery (why pen wins over syringe).

    PubMed

    Asamoah, Ernest

    2008-03-01

    Diabetes affects most aspects of everyday life and places considerable responsibility on the patient; therefore, without patient acceptance of what we offer, the therapy is unlikely to be adhered to especially when that therapy happens to be insulin injection. In 2008, almost every physician/health care provider carries new and sleek cell phones (because the newer ones are well designed and function better). Why these same providers continue to prescribe insulin via syringes in 2008 is something that I cannot fathom. Previously, some insurance companies only paid for vials and there was no other choice, but today almost all insurance pay for pens and so the "insurance reason" is no longer tenable. Since Banting and Best discovered insulin in 1921, scientists have continued to improve the types of insulin (making them mimic physiology more closely in order to minimize hypoglycemia and improve glycemic control as seen with the latest analog insulins). In the same manner, the delivery process of insulin has also continued to evolve to make it easier and more acceptable to patients. Studies have shown that patients prefer device use over traditional vials/syringes. Pen devices used to inject insulin lead to better compliance, are quicker to inject, dosing is much more accurate, and, surprisingly, are more cost effective. I challenge my colleagues to take full responsibility for what their patients use. If a provider believes in pen devices, most of his/her patients will use them. The products your patients use is a direct reflection of what you practice. Educating providers to change their beliefs and practices is key to moving American diabetic patients from syringes to pen devices.

  19. Packaged peristaltic micropump for controlled drug delivery application

    NASA Astrophysics Data System (ADS)

    Vinayakumar, K. B.; Nadiger, Girish; R. Shetty, Vikas; Dinesh, N. S.; Nayak, M. M.; Rajanna, K.

    2017-01-01

    Micropump technology has evolved significantly in the last two decades and is finding a variety of applications ranging from μTAS (micro Total Analysis System) to drug delivery. However, the application area of the micropump is limited owing to: simple pumping mechanism, ease of handling, controlled (microliter to milliliter) delivery, continuous delivery, and accuracy in flow rate. Here, the author presents the design, development, characterization, and precision flow controlling of a DC-motor driven peristaltic pump for controlled drug delivery application. All the micropump components were fabricated using the conventional fabrication technique. The volume flow variation of the pump has been characterized for different viscous fluids. The change in volume flow due to change in back pressure has been presented in detail. The fail-safe mode operation of the pump has been tested and leak rate was measured (˜0.14% leak for an inlet pressure of 140 kPa) for different inlet pressures. The precision volume flow of the pump has been achieved by measuring the pinch cam position and load current. The accuracy in the volume flow has been measured after 300 rotations. Finally, the complete system has been integrated with the necessary electronics and an android application has been developed for the self-administration of bolus and basal delivery of insulin.

  20. Diabetes care and outcomes for American Indians and Alaska natives in commercial integrated delivery systems: a SUrveillance, PREvention, and ManagEment of Diabetes Mellitus (SUPREME-DM) Study.

    PubMed

    Schmittdiel, Julie A; Steiner, John F; Adams, Alyce S; Dyer, Wendy; Beals, Janette; Henderson, William G; Desai, Jay; Morales, Leo S; Nichols, Gregory A; Lawrence, Jean M; Waitzfelder, Beth; Butler, Melissa G; Pathak, Ram D; Hamman, Richard F; Manson, Spero M

    2014-01-01

    To compare cardiovascular disease risk factor testing rates and intermediate outcomes of care between American Indian/Alaska Native (AI/AN) patients with diabetes and non-Hispanic Caucasians enrolled in nine commercial integrated delivery systems in the USA. We used modified Poisson regression models to compare the annual testing rates and risk factor control levels for glycated haemoglobin (HbA1c), low-density lipoprotein cholesterol (LDL-C), and systolic blood pressure (SBP); number of unique diabetes drug classes; insulin use; and oral diabetes drug medication adherence between insured AI/AN and non-Hispanic white adults with diabetes aged ≥18 in 2011. 5831 AI/AN patients (1.8% of the cohort) met inclusion criteria. After adjusting for age, gender, comorbidities, insulin use, and geocoded socioeconomic status, AI/AN patients had similar rates of annual HbA1c, LDL-C, and SBP testing, and LDL-C and SBP control, compared with non-Hispanic Caucasians. However, AI/AN patients were significantly more likely to have HbA1c >9% (>74.9 mmol/mol; RR=1.47, 95% CI 1.38 to 1.58), and significantly less likely to adhere to their oral diabetes medications (RR=0.90, 95% CI 0.88 to 0.93) compared with non-Hispanic Caucasians. AI/AN patients in commercial integrated delivery systems have similar blood pressure and cholesterol testing and control, but significantly lower rates of HbA1c control and diabetes medication adherence, compared with non-Hispanic Caucasians. As more AI/ANs move to urban and suburban settings, clinicians and health plans should focus on addressing disparities in diabetes care and outcomes in this population.

  1. Diabetes care and outcomes for American Indians and Alaska natives in commercial integrated delivery systems: a SUrveillance, PREvention, and ManagEment of Diabetes Mellitus (SUPREME-DM) Study

    PubMed Central

    Schmittdiel, Julie A; Steiner, John F; Adams, Alyce S; Dyer, Wendy; Beals, Janette; Henderson, William G; Desai, Jay; Morales, Leo S; Nichols, Gregory A; Lawrence, Jean M; Waitzfelder, Beth; Butler, Melissa G; Pathak, Ram D; Hamman, Richard F; Manson, Spero M

    2014-01-01

    Objective To compare cardiovascular disease risk factor testing rates and intermediate outcomes of care between American Indian/Alaska Native (AI/AN) patients with diabetes and non-Hispanic Caucasians enrolled in nine commercial integrated delivery systems in the USA. Research design and methods We used modified Poisson regression models to compare the annual testing rates and risk factor control levels for glycated haemoglobin (HbA1c), low-density lipoprotein cholesterol (LDL-C), and systolic blood pressure (SBP); number of unique diabetes drug classes; insulin use; and oral diabetes drug medication adherence between insured AI/AN and non-Hispanic white adults with diabetes aged ≥18 in 2011. Results 5831 AI/AN patients (1.8% of the cohort) met inclusion criteria. After adjusting for age, gender, comorbidities, insulin use, and geocoded socioeconomic status, AI/AN patients had similar rates of annual HbA1c, LDL-C, and SBP testing, and LDL-C and SBP control, compared with non-Hispanic Caucasians. However, AI/AN patients were significantly more likely to have HbA1c >9% (>74.9 mmol/mol; RR=1.47, 95% CI 1.38 to 1.58), and significantly less likely to adhere to their oral diabetes medications (RR=0.90, 95% CI 0.88 to 0.93) compared with non-Hispanic Caucasians. Conclusions AI/AN patients in commercial integrated delivery systems have similar blood pressure and cholesterol testing and control, but significantly lower rates of HbA1c control and diabetes medication adherence, compared with non-Hispanic Caucasians. As more AI/ANs move to urban and suburban settings, clinicians and health plans should focus on addressing disparities in diabetes care and outcomes in this population. PMID:25452877

  2. Customization of home closed-loop insulin delivery in adult patients with type 1 diabetes, assisted with structured remote monitoring: the pilot WP7 Diabeloop study.

    PubMed

    Benhamou, Pierre Yves; Huneker, Erik; Franc, Sylvia; Doron, Maeva; Charpentier, Guillaume

    2018-06-01

    Improvement in closed-loop insulin delivery systems could result from customization of settings to individual needs and remote monitoring. This pilot home study evaluated the efficacy and relevance of this approach. A bicentric clinical trial was conducted for 3 weeks, using an MPC-based algorithm (Diabeloop Artificial Pancreas system) featuring five settings designed to modulate the reactivity of regulation. Remote monitoring was ensured by expert nurses with a web platform generating automatic Secured Information Messages (SIMs) and with a structured procedure. Endpoints were glucose metrics and description of impact of monitoring on regulation parameters. Eight patients with type 1 diabetes (six men, age 41.8 ± 11.4 years, HbA1c 7.7 ± 1.0%) were included. Time spent in the 70-180 mg/dl range was 70.2% [67.5; 76.9]. Time in hypoglycemia < 70 mg/dl was 2.9% [2.1; 3.4]. Eleven SIMs led to phone intervention. Original default settings were modified in all patients by the intervention of the nurses. This pilot trial suggests that the Diabeloop closed-loop system could be efficient regarding metabolic outcomes, whereas its telemedical monitoring feature could contribute to enhanced efficacy and safety. This study is registered at ClinicalTrials.gov with trial registration number NCT02987556.

  3. Enhanced thermogenic program by non-viral delivery of combinatory browning genes to treat diet-induced obesity in mice.

    PubMed

    Park, Hongsuk; Cho, Sungpil; Janat-Amsbury, Margit M; Bae, You Han

    2015-12-01

    Thermogenic program (also known as browning) is a promising and attractive anti-obesity approach. Islet amyloid polypeptide (IAPP) and irisin have emerged as potential browning hormones that hold high potential to treat obesity. Here, we have constructed a dual browning gene system containing both IAPP and irisin (derived from fibronectin type III domain containing 5; FNDC5) combined with 2A and furin self-cleavage sites. Intraperitoneal administration of the construct complexed with a linear polyethylenimine into diet-induced obese mice demonstrated the elevation of anti-obesogenic effects characterized as the decreased body weight, adiposity, and levels of glucose and insulin. In addition, the construct delivery increased energy expenditure and the expression of core molecular determinants associated with browning. The additional advantages of the dual browning gene construct delivery compared to both single gene construct delivery and dual peptide delivery can be emphasized on efficacy and practicability. Hence, we have concluded that dual browning gene delivery makes it therapeutically attractive for diet-induced obesity treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Insulin stimulated-glucose transporter Glut 4 is expressed in the retina.

    PubMed

    Sánchez-Chávez, Gustavo; Peña-Rangel, Ma Teresa; Riesgo-Escovar, Juan R; Martínez-Martínez, Alejandro; Salceda, Rocío

    2012-01-01

    The vertebrate retina is a very metabolically active tissue whose energy demands are normally met through the uptake of glucose and oxygen. Glucose metabolism in this tissue relies upon adequate glucose delivery from the systemic circulation. Therefore, glucose transport depends on the expression of glucose transporters. Here, we show retinal expression of the Glut 4 glucose transporter in frog and rat retinas. Immunohistochemistry and in situ hybridization studies showed Glut 4 expression in the three nuclear layers of the retina: the photoreceptor, inner nuclear and ganglionar cell layers. In the rat retina immunoprecipitation and Western blot analysis revealed a protein with an apparent molecular mass of 45 kDa. ¹⁴C-glucose accumulation by isolated rat retinas was significantly enhanced by physiological concentrations of insulin, an effect blocked by inhibitors of phosphatidyl-inositol 3-kinase (PI3K), a key enzyme in the insulin-signaling pathway in other tissues. Also, we observed an increase in ³H-cytochalasin binding sites in the presence of insulin, suggesting an increase in transporter recruitment at the cell surface. Besides, insulin induced phosphorylation of Akt, an effect also blocked by PI3K inhibition. Expression of Glut 4 was not modified in retinas of a type 1 diabetic rat model. To our knowledge, our results provide the first evidence of Glut4 expression in the retina, suggesting it as an insulin- responsive tissue.

  5. Insulin Stimulated-Glucose Transporter Glut 4 Is Expressed in the Retina

    PubMed Central

    Sánchez-Chávez, Gustavo; Peña-Rangel, Ma. Teresa; Riesgo-Escovar, Juan R.; Martínez-Martínez, Alejandro; Salceda, Rocío

    2012-01-01

    The vertebrate retina is a very metabolically active tissue whose energy demands are normally met through the uptake of glucose and oxygen. Glucose metabolism in this tissue relies upon adequate glucose delivery from the systemic circulation. Therefore, glucose transport depends on the expression of glucose transporters. Here, we show retinal expression of the Glut 4 glucose transporter in frog and rat retinas. Immunohistochemistry and in situ hybridization studies showed Glut 4 expression in the three nuclear layers of the retina: the photoreceptor, inner nuclear and ganglionar cell layers. In the rat retina immunoprecipitation and Western blot analysis revealed a protein with an apparent molecular mass of 45 kDa. 14C-glucose accumulation by isolated rat retinas was significantly enhanced by physiological concentrations of insulin, an effect blocked by inhibitors of phosphatidyl-inositol 3-kinase (PI3K), a key enzyme in the insulin-signaling pathway in other tissues. Also, we observed an increase in 3H-cytochalasin binding sites in the presence of insulin, suggesting an increase in transporter recruitment at the cell surface. Besides, insulin induced phosphorylation of Akt, an effect also blocked by PI3K inhibition. Expression of Glut 4 was not modified in retinas of a type 1 diabetic rat model. To our knowledge, our results provide the first evidence of Glut4 expression in the retina, suggesting it as an insulin- responsive tissue. PMID:23285235

  6. The role of insulin pump therapy for type 2 diabetes mellitus.

    PubMed

    Landau, Zohar; Raz, Itamar; Wainstein, Julio; Bar-Dayan, Yosefa; Cahn, Avivit

    2017-01-01

    Many patients with type 2 diabetes fail to achieve adequate glucose control despite escalation of treatment and combinations of multiple therapies including insulin. Patients with long-standing type 2 diabetes often suffer from the combination of severe insulin deficiency in addition to insulin resistance, thereby requiring high doses of insulin delivered in multiple injections to attain adequate glycemic control. Insulin-pump therapy was first introduced in the 1970s as an approach to mimic physiological insulin delivery and attain normal glucose in patients with type 1 diabetes. The recent years have seen an increase in the use of this technology for patients with type 2 diabetes. This article summarizes the clinical studies evaluating insulin pump use in patients with type 2 diabetes and discusses the benefits and shortcomings of pump therapy in this population. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Misadventures in insulin therapy: are you at risk?

    PubMed Central

    Grissinger, Matthew; Lease, Michael

    2003-01-01

    About dollar 1 out of every dollar 7 spent on health care is related to diabetes mellitus, a leading cause of blindness and kidney failure and a strong risk factor for heart disease. Prevalence of the disease has increased by a third among adults in general in the last decade, but intensive therapy has been shown to delay the onset and slow the progression of diabetes-related complications. While insulin therapy remains key in the management of type 1 diabetes, many patients with type 2, or insulin-resistant, diabetes encounter insulin administration errors that compromise the quality of insulin delivery. Insulin errors are a major, but modifiable, barrier to dosing accuracy and optimal diabetes control for many patients. Future trends to combat the problem include increased use of insulin inhalers and smaller doses of rapid- or short-acting insulin to supplement longer-acting injections. PMID:12653373

  8. Management of the pregnant, insulin-dependent diabetic woman.

    PubMed

    Jovanovic, L; Peterson, C M

    1980-01-01

    An intensive care program was offered to all insulin-dependent, pregnant diabetic women who presented to The New York Hospital Obstetrical Clinic in their eighth week or less of gestation. The patients were hospitalized for 1 wk to normalize their blood glucose and to teach the technique of self-monitored glucose determination, diet and exchange lists, and the method to titrate insulin according to the blood glucose determination. The mean blood glucose for the first 10 patients accepted to the program was 169 mg/dl at the start of the program with a mean hemoglobin A1c of 9.4% for the group (normal < 5.5%) and glucosuria up to 50 g/24 h. After discharge, mean glucose was 91 mg/dl, and urinary glucose excretion was 1.4 g/24 h. HbA1c fell into the normal range 5 wk after normoglycemia was achieved (3.4%) (nl < 5.5%). Normoglycemia was maintained as outpatients until 3 wk before delivery when the patients were readmitted for tests of fetal well-being. Mean weight gain for the mothers was 12.2 kg. Mean glucose at delivery was 87 mg/dl and HbA1c was 3%. Hormonal profiles (hCG, hPRL, estrogens, progesterone, hPL) normalized after normoglycemia was achieved and remained normal until delivery. Mean gestational age at time of delivery was 38.8 wk with a mean infant birth weight of 2988 g. No infant manifested hypoglycemia, hypocalcemia, erythremia, or respiratory disease. The use of self-monitored blood glucose allows for optimal care of the insulin-dependent, pregnant diabetic woman while she remains at home with her family.

  9. Defects in oxygen supply to skeletal muscle of prediabetic ZDF rats

    PubMed Central

    Goldman, Daniel; Hanson, Madelyn; Stephenson, Alan H.; Milkovich, Stephanie; Benlamri, Amina; Ellsworth, Mary L.; Sprague, Randy S.

    2010-01-01

    In humans, prediabetes is characterized by marked increases in plasma insulin and near normal blood glucose levels as well as microvascular dysfunction of unknown origin. Using the extensor digitorum longus muscle of 7-wk inbred male Zucker diabetic fatty rats fed a high-fat diet as a model of prediabetes, we tested the hypothesis that hyperinsulinemia contributes to impaired O2 delivery in skeletal muscle. Using in vivo video microscopy, we determined that the total O2 supply to capillaries in the extensor digitorum longus muscle of prediabetic rats was reduced to 64% of controls with a lower O2 supply rate per capillary and higher O2 extraction resulting in a decreased O2 saturation at the venous end of the capillary network. These findings suggest a lower average tissue Po2 in prediabetic animals. In addition, we determined that insulin, at concentrations measured in humans and Zucker diabetic fatty rats with prediabetes, inhibited the O2-dependent release of ATP from rat red blood cells (RBCs). This inability to release ATP could contribute to the impaired O2 delivery observed in rats with prediabetes, especially in light of the finding that the endothelium-dependent relaxation of resistance arteries from these animals is not different from controls and is not altered by insulin. Computational modeling confirmed a significant 8.3-mmHg decrease in average tissue Po2 as well as an increase in the heterogeneity of tissue Po2, implicating a failure of a regulatory system for O2 supply. The finding that insulin attenuates the O2-dependent release of ATP from RBCs suggests that this defect in RBC physiology could contribute to a failure in the regulation of O2 supply to meet the demand in skeletal muscle in prediabetes. PMID:20207810

  10. A model of insulin delivery by a controlled release micropump.

    PubMed

    Allen, D G; Sefton, M V

    1986-01-01

    A model has been developed to describe the delivery of insulin from a controlled release micropump (CRM). Basal delivery was provided by diffusion due to a concentration difference driving force across the CRM. This was modelled by considering the CRM to be a series of one-dimensional steady-state diffusion resistances. This delivery model was used to size prototypes and identify the piston, foam and the pump outlet as the controlling resistances to basal insulin transport. Augmented delivery by the CRM was achieved by repeated compression of a foam disk by a mild steel piston which was driven by a solenoid (tested voltage range 0-173 V DC; 5 msec "on" time; frequency 20-40 min-1). The increased delivery was attributed to the combination of mixing inside the pump barrel and displacement of barrel contents into the downstream reservoir. This action was approximated by a three-compartment model, which considered the CRM to consist of a well-mixed upstream reservoir and pump barrel (with a downstream reservoir) separated by two resistances: a constant upstream membrane resistance, (KmAm)-1, and a variable downstream mixing rate resistance, (Qd)-1. A least squares fit of the model to experimental data showed Qd to increase with the cube of the force on the piston and linearly with the compression frequency. In agreement with experimental results, the model predicted the upstream membrane to be rate controlling only at augmented pump resistances close to the value (KmAm)-1. These models were used to design an improved prototype (VIII) which is now being evaluated in vivo in pancreatectomized dogs for its efficacy in restoring and sustaining normoglycemia.

  11. Pharmacokinetic and Pharmacodynamic Properties of a Novel Inhaled Insulin

    PubMed Central

    Heinemann, Lutz; Baughman, Robert; Boss, Anders; Hompesch, Marcus

    2016-01-01

    Advances in insulin treatment options over recent decades have markedly improved the management of diabetes. Despite this, glycemic control remains suboptimal in many people with diabetes. Although postprandial glucose control has been improved with the development of subcutaneously injected rapid-acting insulin analogs, currently available insulins are not able to fully mimic the physiological time–action profile of endogenously secreted insulin after a meal. The delayed onset of metabolic action and prolonged period of effect induce the risk of postprandial hyperglycemia and late postprandial hypoglycemia. A number of alternative routes of insulin administration have been investigated over time in an attempt to overcome the limitations associated with subcutaneous administration and to provide an improved time–action insulin profile more closely simulating physiological prandial insulin release. Among these, pulmonary insulin delivery has shown the most promise. Technosphere® Inhaled Insulin (TI) is a rapid-acting inhaled human insulin recently approved by the FDA for prandial insulin therapy. In this article we discuss the pharmacokinetic and pharmacodynamic properties of TI, and, based on key studies performed during its clinical development, the implications for improved postprandial glucose control. PMID:27378794

  12. Continuous subcutaneous insulin infusion therapy and multiple daily insulin injections in type 1 diabetes mellitus: a comparative overview and future horizons.

    PubMed

    Thabit, Hood; Hovorka, Roman

    2016-01-01

    Continuous subcutaneous insulin infusion (CSII) therapy is currently accepted as a treatment strategy for type 1 diabetes. Transition from multiple daily injection therapy (MDI; including basal-bolus regimens) to CSII is based on expectations of better metabolic control and fewer hypoglycaemic events. Evidence to date has not been always conclusive. Evidence for CSII and MDI in terms of glycaemic control, hypoglycaemia and psychosocial outcomes is reviewed in the adult and paediatric population with type 1 diabetes. Findings from studies on threshold-based insulin pump suspension and predictive low glucose management (PLGM) are outlined. Limitations of current CSII application and future technological developments are discussed. Glycaemic control and quality of life (QOL) may be improved by CSII compared to MDI depending on baseline HbA1c and hypoglycaemia rates. Future studies are expected to provide evidence on clinical and cost effectiveness in those who will benefit the most. Training, structured education and support are important to benefit from CSII. Novel technological approaches linking continuous glucose monitoring (CGM) and CSII may help mitigate against frequent hypoglycaemia in those at risk. Development of glucose-responsive automated closed-loop insulin delivery systems may reduce the burden of disease management and improve outcomes in type 1 diabetes.

  13. Sustained co-delivery of BIO and IGF-1 by a novel hybrid hydrogel system to stimulate endogenous cardiac repair in myocardial infarcted rat hearts.

    PubMed

    Fang, Rui; Qiao, Shupei; Liu, Yi; Meng, Qingyuan; Chen, Xiongbiao; Song, Bing; Hou, Xiaolu; Tian, Weiming

    2015-01-01

    Dedifferentiation and proliferation of endogenous cardiomyocytes in situ can effectively improve cardiac repair following myocardial infarction (MI). 6-Bromoindirubin-3-oxime (BIO) and insulin-like growth factor 1 (IGF-1) are two potent factors that promote cardiomyocyte survival and proliferation. However, their delivery for sustained release in MI-affected areas has proved to be challenging. In the current research, we present a study on the sustained co-delivery of BIO and IGF-1 in a hybrid hydrogel system to simulate endogenous cardiac repair in an MI rat model. Both BIO and IGF-1 were efficiently encapsulated in gelatin nanoparticles, which were later cross-linked with the oxidized alginate to form a novel hybrid hydrogel system. The in vivo results indicated that the hybrid system could enhance the proliferation of cardiomyocytes in situ and could promote revascularization around the MI sites, allowing improved cardiac function. Taken together, we concluded that the hybrid hydrogel system can co-deliver BIO and IGF-1 to areas of MI and thus improve cardiac function by promoting the proliferation of cardiomyocytes and revascularization.

  14. Sustained co-delivery of BIO and IGF-1 by a novel hybrid hydrogel system to stimulate endogenous cardiac repair in myocardial infarcted rat hearts

    PubMed Central

    Fang, Rui; Qiao, Shupei; Liu, Yi; Meng, Qingyuan; Chen, Xiongbiao; Song, Bing; Hou, Xiaolu; Tian, Weiming

    2015-01-01

    Dedifferentiation and proliferation of endogenous cardiomyocytes in situ can effectively improve cardiac repair following myocardial infarction (MI). 6-Bromoindirubin-3-oxime (BIO) and insulin-like growth factor 1 (IGF-1) are two potent factors that promote cardiomyocyte survival and proliferation. However, their delivery for sustained release in MI-affected areas has proved to be challenging. In the current research, we present a study on the sustained co-delivery of BIO and IGF-1 in a hybrid hydrogel system to simulate endogenous cardiac repair in an MI rat model. Both BIO and IGF-1 were efficiently encapsulated in gelatin nanoparticles, which were later cross-linked with the oxidized alginate to form a novel hybrid hydrogel system. The in vivo results indicated that the hybrid system could enhance the proliferation of cardiomyocytes in situ and could promote revascularization around the MI sites, allowing improved cardiac function. Taken together, we concluded that the hybrid hydrogel system can co-deliver BIO and IGF-1 to areas of MI and thus improve cardiac function by promoting the proliferation of cardiomyocytes and revascularization. PMID:26251592

  15. pH sensitive thiolated cationic hydrogel for oral insulin delivery.

    PubMed

    Sonia, T A; Sharma, Chandra P

    2014-04-01

    The objective of this work is to study the efficacy of pH sensitive thiolated Polydimethylaminoethylmethacrylate for oral delivery of insulin. Synthesis of pH sensitive thiolated Polydimethylaminoethylmethacrylate (PDCPA) was carried out by crosslinking Polymethacrylic acid with thiolated Polydimethylaminoethylmethacrylate (PDCys) via carbodiimide chemistry. Prior to in vivo experiment, various physicochemical and biological characterisation were carried out to evaluate the efficacy of PDCPA. Modification was confirmed by IR and NMR spectroscopy. The particle size was found to be 284 nm with a zeta potential of 37.3+/-1.58 mV. Texture analyser measurements showed that PDCPA is more mucoadhesive than the parent polymer. Transepithelial electrical measurements showed a reduction of greater than 50% on incubation with PDCPA particles. Permeation studies showed that PDCPA is more permeable than the parent polymer. On in vivo evaluation on male diabetic rats, insulin loaded PDCPA exhibited a blood glucose reduction of 19%.

  16. Diabetes: Models, Signals and control

    NASA Astrophysics Data System (ADS)

    Cobelli, C.

    2010-07-01

    Diabetes and its complications impose significant economic consequences on individuals, families, health systems, and countries. The control of diabetes is an interdisciplinary endeavor, which includes significant components of modeling, signal processing and control. Models: first, I will discuss the minimal (coarse) models which describe the key components of the system functionality and are capable of measuring crucial processes of glucose metabolism and insulin control in health and diabetes; then, the maximal (fine-grain) models which include comprehensively all available knowledge about system functionality and are capable to simulate the glucose-insulin system in diabetes, thus making it possible to create simulation scenarios whereby cost effective experiments can be conducted in silico to assess the efficacy of various treatment strategies - in particular I will focus on the first in silico simulation model accepted by FDA as a substitute to animal trials in the quest for optimal diabetes control. Signals: I will review metabolic monitoring, with a particular emphasis on the new continuous glucose sensors, on the crucial role of models to enhance the interpretation of their time-series signals, and on the opportunities that they present for automation of diabetes control. Control: I will review control strategies that have been successfully employed in vivo or in silico, presenting a promise for the development of a future artificial pancreas and, in particular, I will discuss a modular architecture for building closed-loop control systems, including insulin delivery and patient safety supervision layers.

  17. A Review of Insulin Pen Devices and Use in the Elderly Diabetic Population

    PubMed Central

    Wright, Bradley M.; Bellone, Jessica M.; McCoy, Emily K.

    2010-01-01

    The prevalence of diabetes mellitus (DM) in the elderly population currently represents almost one-half of the overall diabetic population. Treatment of DM often requires a multidrug regimen that includes insulin therapy; however, due to concomitant comorbidities such as dementia, vision loss, neuropathies, poor mobility, and poor manual dexterity, elderly patients may be at increase risk for hypoglycemia and other dosing errors that are associated with insulin administration. Insulin pen devices have been shown to provide more reliable, accurate, and simplified dosing, and therefore may be a safer, easier, and more acceptable method of insulin delivery in the elderly population. This review will describe the various insulin pen devices available today, as well as discuss the potential advantages of these devices in the elderly population. PMID:22879787

  18. A novel nanoemulsion-based method to produce ultrasmall, water-dispersible nanoparticles from chitosan, surface modified with cell-penetrating peptide for oral delivery of proteins and peptides

    PubMed Central

    Barbari, Ghullam Reza; Dorkoosh, Farid Abedin; Amini, Mohsen; Sharifzadeh, Mohammad; Atyabi, Fateme; Balalaie, Saeed; Rafiee Tehrani, Niyousha; Rafiee Tehrani, Morteza

    2017-01-01

    A simple and reproducible water-in-oil (W/O) nanoemulsion technique for making ultrasmall (<15 nm), monodispersed and water-dispersible nanoparticles (NPs) from chitosan (CS) is reported. The nano-sized (50 nm) water pools of the W/O nanoemulsion serve as “nano-containers and nano-reactors”. The entrapped polymer chains of CS inside these “nano-reactors” are covalently cross-linked with the chains of polyethylene glycol (PEG), leading to rigidification and formation of NPs. These NPs possess excessive swelling properties in aqueous medium and preserve integrity in all pH ranges due to chemical cross-linking with PEG. A potent and newly developed cell-penetrating peptide (CPP) is further chemically conjugated to the surface of the NPs, leading to development of a novel peptide-conjugated derivative of CS with profound tight-junction opening properties. The CPP-conjugated NPs can easily be loaded with almost all kinds of proteins, peptides and nucleotides for oral delivery applications. Feasibility of this nanoparticulate system for oral delivery of a model peptide (insulin) is investigated in Caco-2 cell line. The cell culture results for translocation of insulin across the cell monolayer are very promising (15%–19% increase), and animal studies are actively under progress and will be published separately. PMID:28496323

  19. Recent developments in protein and peptide parenteral delivery approaches

    PubMed Central

    Patel, Ashaben; Cholkar, Kishore; Mitra, Ashim K

    2014-01-01

    Discovery of insulin in the early 1900s initiated the research and development to improve the means of therapeutic protein delivery in patients. In the past decade, great emphasis has been placed on bringing protein and peptide therapeutics to market. Despite tremendous efforts, parenteral delivery still remains the major mode of administration for protein and peptide therapeutics. Other routes such as oral, nasal, pulmonary and buccal are considered more opportunistic rather than routine application. Improving biological half-life, stability and therapeutic efficacy is central to protein and peptide delivery. Several approaches have been tried in the past to improve protein and peptide in vitro/in vivo stability and performance. Approaches may be broadly categorized as chemical modification and colloidal delivery systems. In this review we have discussed various chemical approaches such as PEGylation, hyperglycosylation, mannosylation, and colloidal carriers including microparticles, nanoparticles, liposomes, carbon nanotubes and micelles for improving protein and peptide delivery. Recent developments on in situ thermosensitive gel-based protein and peptide delivery have also been described. This review summarizes recent developments on some currently existing approaches to improve stability, bioavailability and bioactivity of peptide and protein therapeutics following parenteral administration. PMID:24592957

  20. Effect of soybean-lecithin as an enhancer of buccal mucosa absorption of insulin.

    PubMed

    Tian, Weiqun; Hu, Qiaolin; Xu, Ying; Xu, Yi

    2012-01-01

    Transmucosal delivery is a suitable route for insulin non-injection administration. In order to understand how insulin passes through mucosa with soybean-lecithin as an enhancing absorption. The penetration rate of insulin molecular through porcine buccal mucosa was investigated by measuring transbuccal fluxes in the Ussing Chambers. The imaging morphology of rabbits buccal mucosa was analyzed by using non-contact mode atomic force microscopy. The permeation rate can be increased by co-administration of soybean-lecithin. Untreated buccal mucosa showed relatively smooth surface characteristics, with many small crater-like pits and indentations spread over mucosa surfaces. Buccal mucosa that had been treated with 1.0% (w/v) sodium deoxycholic acid (pH 7.4) appeared to much more indentations characteristic, which treated with 2.5% (w/v) soybean-lecithin (pH 7.4) and 2.5% (w/v) Azone or laurocapram (pH 7.4) appeared rather different, the surface mucosa treated with soybean-lecithin emulsion showed a fine, rippling effect whereas those exposed to Azone display a more coarse, undulating surface feature. As a result of that Azone could damage the surface of the buccal mucosa, but soybean-lecithin could not. This study demonstrated that soybean-lecithin is a better and safer enhancer for insulin transmucosal delivery.

  1. Improving the Computational Effort of Set-Inversion-Based Prandial Insulin Delivery for Its Integration in Insulin Pumps

    PubMed Central

    León-Vargas, Fabian; Calm, Remei; Bondia, Jorge; Vehí, Josep

    2012-01-01

    Objective Set-inversion-based prandial insulin delivery is a new model-based bolus advisor for postprandial glucose control in type 1 diabetes mellitus (T1DM). It automatically coordinates the values of basal–bolus insulin to be infused during the postprandial period so as to achieve some predefined control objectives. However, the method requires an excessive computation time to compute the solution set of feasible insulin profiles, which impedes its integration into an insulin pump. In this work, a new algorithm is presented, which reduces computation time significantly and enables the integration of this new bolus advisor into current processing features of smart insulin pumps. Methods A new strategy was implemented that focused on finding the combined basal–bolus solution of interest rather than an extensive search of the feasible set of solutions. Analysis of interval simulations, inclusion of physiological assumptions, and search domain contractions were used. Data from six real patients with T1DM were used to compare the performance between the optimized and the conventional computations. Results In all cases, the optimized version yielded the basal–bolus combination recommended by the conventional method and in only 0.032% of the computation time. Simulations show that the mean number of iterations for the optimized computation requires approximately 3.59 s at 20 MHz processing power, in line with current features of smart pumps. Conclusions A computationally efficient method for basal–bolus coordination in postprandial glucose control has been presented and tested. The results indicate that an embedded algorithm within smart insulin pumps is now feasible. Nonetheless, we acknowledge that a clinical trial will be needed in order to justify this claim. PMID:23294789

  2. Comparison of glyburide and insulin in women with gestational diabetes mellitus and associated perinatal outcome: a randomized clinical trial.

    PubMed

    Mirzamoradi, Masoomeh; Heidar, Zahra; Faalpoor, Ziba; Naeiji, Zahra; Jamali, Razyeh

    2015-01-01

    Insulin is currently the drug of choice in treating patients with gestational diabetes mellitus but insulin is expensive, inconvenient to store and use and probably associated with more risks of asymptomatic hypoglycemia in comparison with some oral agents. This randomized clinical trial was conducted to evaluate the efficacy and safety of glyburide in patients with gestational diabetes mellitus in comparison with insulin therapy. Pregnant women aged between 18-45 years with singleton pregnancies and in their 24-36 weeks of gestation were assessed for eligibility. Women with gestational diabetes mellitus were randomly allocated to two insulin and glyburide groups and compared with maternal and neonatal outcome. Ninety-six women with gestational diabetes mellitus enrolled in the study. At screen and treated fasting and post-prandial blood glucose levels were similar in both groups. Time for beginning the treatment to control the glycemic index was 28.30 (±20.60) days in the insulin group and 22.56 (±18.86) in the glyburide group. There was no statistically significant difference in time-to-control the blood glucose level in two studied group. Time, between beginning the treatment of GDM and delivery, was 53.22 (±28.96) days in the insulin group and 56.67 (±30.47) in the glyburide group. There was no statistically significant difference between the times of treatment-to-delivery in two studied groups. There were no statistically significant differences between maternal and neonatal outcomes in two studied groups. Glyburide can effectively and safely control the glycemic index in women with gestational diabetes mellitus in comparison with insulin.

  3. Flow induced protein nucleation: Insulin oligomerization under shear.

    NASA Astrophysics Data System (ADS)

    Dexter, Andrew; Azadani, Ali; Sorci, Mirco; Belfort, Georges; Hirsa, Amir

    2007-11-01

    A large number of diseases are associated with protein aggregation and misfolding, such as Alzheimer's, Parkinson's and human prion diseases such as Creutzveld-Jakob disease. Characteristic of these diseases is the presence of amyloid fibrils and their precursors, oligomers and protofibrils. Considerable evidence exists that a shearing flow strongly influences amyloid formation both in vitro and in vivo. Furthermore, the stability of protein-based pharmaceuticals is essential for conventional therapeutic preparations and drug delivery systems. By studying the nucleation and growth of insulin fibrils in a well-defined flow system, we expect to identify the flow conditions that impact protein aggregation kinetics and which lead to protein destabilization. The present flow system consists of an annular region bounded by stationary inner and outer cylinders and is driven by rotation of the floor. Preliminary results indicate that a continuous shearing flow can accelerate the aggregation process. The interfacial shear viscosity was found to drastically increase during aggregation and appears to be a useful parameter to probe protein oligomerization and the effects of flow.

  4. Insulin Therapy for Diabetes Epidemic: A patent Review.

    PubMed

    Tandon, Runjhun; Luxami, Vijay; Dosanjh, Harmanjit Singh; Tandon, Nitin; Paul, Kamaldeep

    2018-02-28

    Diabetes is a serious and chronic problem that can be attributed to the insufficient release of the insulin or when body does not respond to the insulin which is already present. This disease has been targeted for corrective action and implementation among four non-communicable diseases by world leaders according to WHO report. The prevalence of diabetes has been estimated to be double from 4.7% of adult population in 1980 to 8.5% in the present scenario. The estimated deaths due to this epidemic disease were 1.5 million in 2012 alone. Currently, approximate 400 million people are suffering from diabetes worldwide. Although the factors leading to Type I diabetes are unknown, there are many therapies available in market for Type II disease which bags more than 90% of the total diabetes cases. But, the current treatment for this disease seems to be lacking in terms of proper management of disease while insulin still remains the ultimate therapy to achieve comparatively effective glycemic control. In this review, an attempt has been made to summarize the patent applications filed in the field of pulmonary delivery of insulin as dry powder through inhaler in various formulations. This review will provide an insight to the development and advancement for various formulations of insulin and the design of inhaler to improve the bioavailability of powder formulation of insulin, which would provide an alternate treatment with better acceptability or tolerability among the patients as compared to the intravenous delivery to offer better management of epidemic diabetes. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Treating type 1 diabetes: from strategies for insulin delivery to dual hormonal control

    PubMed Central

    McCall, A. L.; Farhy, L. S.

    2014-01-01

    Type 1 diabetes is a disorder where slow destruction of pancreatic β-cells occurs through autoimmune mechanisms. The result is a progressive and ultimately complete lack of endogenous insulin. Due to β-cell lack, secondary abnormalities in glucagon and likely in incretins occur. These multiple hormonal abnormalities cause metabolic instability and extreme glycemic variability, which is the primary phenotype. As the disease progresses patients often develop hypoglycemia unawareness and defects in their counterregulatory defenses. Intensive insulin therapy may thus lead to 3-fold excess of severe hypoglycemia and severely hinder the effective and safe control of hyperglycemia. The main goal of the therapy for type 1 diabetes has long been physiological mimicry of normal insulin secretion based on monitoring which requires considerable effort and understanding of the underlying physiology. Attainment of this goal is challenged by the nature of the disease and our current lack of means to fully repair the abnormal endocrine pancreas interactive functions. As a result, various insulin preparations has been developed to partially compensate for the inability to deliver timely exogenous insulin directly to the portal/intrapancreatic circulation. It remains an ongoing task to identify the ideal routes and regimens of their delivery and potentially that of other hormones to restore the deficient and disordered hormonal environment of the pancreas to achieve a near normal metabolic state. Several recent technological advances help addressing these goals, including the rapid progress in insulin pumps, continuous glucose sensors, and ultimately the artificial pancreas closed-loop technology and the recent start of dual-hormone therapies. PMID:23732369

  6. A Retrospective Review of the Clinical Characteristics and Blood Glucose Data from Cellnovo System Users using Data Collected from the Cellnovo Online Platform.

    PubMed

    Hautier-Suply, Olivia; Friedmann, Yasmin; Shapley, Julian

    2018-04-01

    Technological advances have led to innovative insulin delivery systems for patients with type 1 diabetes mellitus. In particular, the combination of miniature engineering and software algorithms contained in continuous subcutaneous insulin infusion (CSII) system pumps provide the user and the healthcare practitioner with an opportunity to review and adjust blood glucose (BG) levels according to system feedback, and to modify or programme their regimen according to their needs. While CSII pumps record a number of data parameters such as BG level, carbohydrate intake, activity and insulin delivered, these data are generally 'locked in' and can only be accessed by uploading to a cloud-based system, thus information is not contemporaneous. The Cellnovo Diabetes Management System (Cellnovo, Bridgend, UK) allows data to be transmitted securely and wirelessly in real time to a secure server, which is then retrieved by an online platform, the Cellnovo Online platform, enabling continuous access by the user and by clinicians. In this article, the authors describe a retrospective review of the patient data automatically uploaded to the Cellnovo Online platform. Baseline clinical and demographic characteristics collected at the start of pump therapy are shown for all patients, and BG data from a sub-cohort of patients who have been using the system for at least 6 months and who take and record an average of three BG level tests per day are presented to demonstrate glycaemic data over time.

  7. Prokineticin Receptor‐1 Is a New Regulator of Endothelial Insulin Uptake and Capillary Formation to Control Insulin Sensitivity and Cardiovascular and Kidney Functions

    PubMed Central

    Dormishian, Mojdeh; Turkeri, Gulen; Urayama, Kyoji; Nguyen, Thu Lan; Boulberdaa, Mounia; Messaddeq, Nadia; Renault, Gilles; Henrion, Daniel; Nebigil, Canan G.

    2013-01-01

    Background Reciprocal relationships between endothelial dysfunction and insulin resistance result in a vicious cycle of cardiovascular, renal, and metabolic disorders. The mechanisms underlying these impairments are unclear. The peptide hormones prokineticins exert their angiogenic function via prokineticin receptor‐1 (PKR1). We explored the extent to which endothelial PKR1 contributes to expansion of capillary network and the transcapillary passage of insulin into the heart, kidney, and adipose tissues, regulating organ functions and metabolism in a specific mice model. Methods and Results By combining cellular studies and studies in endothelium‐specific loss‐of‐function mouse model (ec‐PKR1−/−), we showed that a genetically induced PKR1 loss in the endothelial cells causes the impaired capillary formation and transendothelial insulin delivery, leading to insulin resistance and cardiovascular and renal disorders. Impaired insulin delivery in endothelial cells accompanied with defective expression and activation of endothelial nitric oxide synthase in the ec‐PKR1−/− aorta, consequently diminishing endothelium‐dependent relaxation. Despite having a lean body phenotype, ec‐PKR1−/− mice exhibited polyphagia, polydipsia, polyurinemia, and hyperinsulinemia, which are reminiscent of human lipodystrophy. High plasma free fatty acid levels and low leptin levels further contribute to the development of insulin resistance at the later age. Peripheral insulin resistance and ectopic lipid accumulation in mutant skeletal muscle, heart, and kidneys were accompanied by impaired insulin‐mediated Akt signaling in these organs. The ec‐PKR1−/− mice displayed myocardial fibrosis, low levels of capillary formation, and high rates of apoptosis, leading to diastolic dysfunction. Compact fibrotic glomeruli and high levels of phosphate excretion were found in mutant kidneys. PKR1 restoration in ec‐PKR1−/− mice reversed the decrease in capillary recruitment and insulin uptake and improved heart and kidney function and insulin resistance. Conclusions We show a novel role for endothelial PKR1 signaling in cardiac, renal, and metabolic functions by regulating transendothelial insulin uptake and endothelial cell proliferation. Targeting endothelial PKR1 may serve as a therapeutic strategy for ameliorating these disorders. PMID:24152983

  8. Impaired postprandial tissue regulation of blood flow in insulin resistance: a determinant of cardiovascular risk?

    PubMed

    Summers, L K; Samra, J S; Frayn, K N

    1999-11-01

    The insulin resistant state is a major risk factor for coronary artery disease. This increased risk is likely to be due to associated lipid and coagulation abnormalities rather than just abnormalities in glucose metabolism or hyperinsulinaemia alone. Exaggerated postprandial lipaemia is a well-recognised associate of insulin resistance and postprandial hypertriglyceridaemia is particularly important in the development of coronary atheroma. It seems likely that insulin is one of the hormonal regulators of adipose tissue and skeletal muscle blood flow. The reduced blood flow and blunting of the postprandial rise of peripheral blood flow in insulin resistance may decrease chylomicron-triglyceride delivery to muscle in subjects with insulin resistance. This, in turn, will lead to increased production of atherogenic particles. We propose that impaired postprandial vasodilation, already recognised as a key feature of glucose intolerance, is also the cause of impaired lipid metabolism in insulin resistant subjects and predisposes them to cardiovascular disease.

  9. Evaluation of current trends and recent development in insulin therapy for management of diabetes mellitus.

    PubMed

    Nawaz, Muhammad Sarfraz; Shah, Kifayat Ullah; Khan, Tahir Mehmood; Rehman, Asim Ur; Rashid, Haroon Ur; Mahmood, Sajid; Khan, Shahzeb; Farrukh, Muhammad Junaid

    2017-12-01

    Diabetes mellitus is a major health problem in developing countries. There are various insulin therapies to manage diabetes mellitus. This systematic review evaluates various insulin therapies for management of diabetes mellitus worldwide. This review also focuses on recent developments being explored for better management of diabetes mellitus. We reviewed a number of published articles from 2002 to 2016 to find out the appropriate management of diabetes mellitus. The paramount parameters of the selected studies include the insulin type & its dose, type of diabetes, duration and comparison of different insulin protocols. In addition, various newly developed approaches for insulin delivery with potential output have also been evaluated. A great variability was observed in managing diabetes mellitus through insulin therapy and the important controlling factors found for this therapy include; dose titration, duration of insulin use, type of insulin used and combination therapy of different insulin. A range of research articles on current trends and recent advances in insulin has been summarized, which led us to the conclusion that multiple daily insulin injections or continuous subcutaneous insulin infusion (insulin pump) is the best method to manage diabetes mellitus. In future perspectives, development of the oral and inhalant insulin would be a tremendous breakthrough in Insulin therapy. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  10. Oral delivery of insulin via polyethylene imine-based nanoparticles for colonic release allows glycemic control in diabetic rats.

    PubMed

    Salvioni, Lucia; Fiandra, Luisa; Del Curto, Maria Dorly; Mazzucchelli, Serena; Allevi, Raffaele; Truffi, Marta; Sorrentino, Luca; Santini, Benedetta; Cerea, Matteo; Palugan, Luca; Corsi, Fabio; Colombo, Miriam

    2016-08-01

    In this study, insulin-containing nanoparticles were loaded into pellet cores and orally administered to diabetic rats. Polyethylene imine-based nanoparticles, either placebo or loaded with insulin, were incorporated by extrusion and spheronization technology into cores that were subsequently coated with three overlapping layers and a gastroresistant film. The starting and coated systems were evaluated in vitro for their physico-technololgical characteristics, as well as disintegration and release performance. Nanoparticles-loaded cores showed homogeneous particle size distribution and shape. When a superdisintegrant and a soluble diluent were included in the composition enhanced disintegration and release performance were observed. The selected formulations, coated either with enteric or three-layer films, showed gastroresistant and release delayed behavior in vitro, respectively. The most promising formulations were finally tested for their hypoglycemic effect in diabetic rats. Only the nanoformulations loaded into the three-layer pellets were able to induce a significant hypoglycemic activity in diabetic rats. Our results suggest that this efficient activity could be attributed to a retarded release of insulin into the distal intestine, characterized by relatively low proteolytic activity and optimal absorption. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. New technology, new errors: how to prime an upgrade of an insulin infusion pump.

    PubMed

    Rule, Ann M; Drincic, Andjela; Galt, Kimberly A

    2007-03-01

    A series of use errors occurred when switching an ambulatory care clinic patient from an older model to a newer model of an ambulatory continuous subcutaneous insulin infusion pump. The nurse practitioner (N.P.) reviewed the new pump's mechanics with the patient, who had a 26-year history of Type 1 diabetes mellitus, and supervised the patient's programming of the pump. At bedtime, a blood sugar of > 250 mg/dL prompted the patient to give herself insulin via the pump. The next morning, she was treated at the emergency department for diabetic ketoacidosis. The pump had been improperly primed, resulting in no insulin delivery. The incident also reflected the absence of a fail-safe mechanism(s) on the pump to alert the user to the improper priming and inappropriate handoff of the patient's care. Unlike the old pump, the new pump did not require manual priming. The lack of delivery of insulin resulted in DKA, a potentially life-threatening complication of diabetes. A root cause analysis suggested several important safety issues, including skipping of steps on the patient training checklist and other shortcuts in patient training. The clinic developed policies and procedures, including mandatory formal training for each pump model by the certified pump trainer and for initiation of insulin pump therapy. This case illustrates the importance of a structured device selection process, provider education, patient education, and monitoring for safety and effectiveness of technological devices in care.

  12. Functional characterisation and permeation studies of lyophilised thiolated chitosan xerogels for buccal delivery of insulin.

    PubMed

    Boateng, Joshua S; Mitchell, John C; Pawar, Harshavardhan; Ayensu, Isaac

    2014-01-01

    Stable and mucoadhesive, lyophilised, thiolated chitosan xerogels, loaded with insulin for buccal mucosa deliv- ery, in place of the currently used parenteral route have been developed. The xerogels were backed with impervious ethyl- cellulose laminate to ensure unidirectional release and also loaded with enzyme inhibitor to enhance insulin permeability across the buccal mucosa. Characterisation of xerogels using(1) HNMR confirmed the degree of deacetylation of the syn- thesised thiolated chitosan. The amount of thiol groups immobilised on the modified chitosan was quantified by Ellman's reaction and molecular weight monitored by gel permeation chromatography. The stability of the secondary structure of insulin was examined by attenuated total reflectance Fourier transform infra-red spectroscopy and circular dichroism. In vitro and ex vivo permeation studies were undertaken by using EpiOral ™ and sheep buccal membrane respectively. Insu- lin released from thiolated chitosan xerogels, loaded with aprotinin (enzyme inhibitor and permeation enhancer) showed a 1.7-fold increase in permeation through EpiOral ™ buccal tissue construct compared to the pure drug. However, permea- tion was decreased for xerogels containing the enzyme inhibitor glutathione. Further, aprotinin containing xerogels en- hanced insulin permeation through sheep buccal membrane and demonstrated good linear correlation with the permeation data from the EpiOral ™ study. The results show the potential application of lyoph ilised thiolated chitosan xerogels con- taining aprotinin with improved mucoadhesion, penetration enhancing and enzyme inhibition characteristics for buccal mucosa delivery of macromolecules such as insulin.

  13. The insulin response integrates increased TGF-β signaling through Akt-induced enhancement of cell surface delivery of TGF-β receptors

    PubMed Central

    Budi, Erine H.; Muthusamy, Baby Periyanayaki; Derynck, Rik

    2015-01-01

    Increased activity of transforming growth factor β (TGF-β), which binds to and stimulates cell surface receptors, contributes to cancer progression and fibrosis by driving epithelial cells toward a migratory mesenchymal phenotype and increasing the abundance of extracellular matrix proteins. The abundance of TGF-β receptors at the cell surface determines cellular responsiveness to TGF-β, which is often produced by the same cells that have the receptors, and thus serves as an autocrine signal. We found that Akt-mediated phosphorylation of AS160, a RabGAP [guanosine triphosphatase (GTPase)-activating protein] promoted the translocation of TGF-β receptors from intracellular stores to the plasma membrane of mouse embryonic fibroblasts (MEFs) and NMuMG epithelial cells. Consequently, insulin, which is commonly used to treat hyperglycemia and activates Akt signaling, increased the amount of TGF-β receptors at the cell surface, thereby enhancing TGF-β responsiveness. This insulin-induced increase in autocrine TGF-β signaling contributed to insulin-induced gene expression responses, attenuated the epithelial phenotype, and promoted the migration of NMuMG cells. Furthermore, the enhanced delivery of TGF-β receptors at the cell surface enabled insulin to increase TGF-β-induced gene responses. The enhancement of TGF-β responsiveness in response to Akt activation may help to explain the biological effects of insulin, the progression of cancers in which Akt is activated, and the increased incidence of fibroses in diabetes. PMID:26420907

  14. Scalable fabrication of size-controlled chitosan nanoparticles for oral delivery of insulin.

    PubMed

    He, Zhiyu; Santos, Jose Luis; Tian, Houkuan; Huang, Huahua; Hu, Yizong; Liu, Lixin; Leong, Kam W; Chen, Yongming; Mao, Hai-Quan

    2017-06-01

    Controlled delivery of protein would find diverse therapeutic applications. Formulation of protein nanoparticles by polyelectrolyte complexation between the protein and a natural polymer such as chitosan (CS) is a popular approach. However, the current method of batch-mode mixing faces significant challenges in scaling up while maintaining size control, high uniformity, and high encapsulation efficiency. Here we report a new method, termed flash nanocomplexation (FNC), to fabricate insulin nanoparticles by infusing aqueous solutions of CS, tripolyphosphate (TPP), and insulin under rapid mixing condition (Re > 1600) in a multi-inlet vortex mixer. In comparison with the bulk-mixing method, the optimized FNC process produces CS/TPP/insulin nanoparticles with a smaller size (down to 45 nm) and narrower size distribution, higher encapsulation efficiency (up to 90%), and pH-dependent nanoparticle dissolution and insulin release. The CS/TPP/insulin nanoparticles can be lyophilized and reconstituted without loss of activity, and produced at a throughput of 5.1 g h -1 when a flow rate of 50 mL min -1 is used. Evaluated in a Type I diabetes rat model, the smaller nanoparticles (45 nm and 115 nm) control the blood glucose level through oral administration more effectively than the larger particles (240 nm). This efficient, reproducible and continuous FNC technique is amenable to scale-up in order to address the critical barrier of manufacturing for the translation of protein nanoparticles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Automatic Detection and Estimation of Unannounced Meals for Multivariable Artificial Pancreas System.

    PubMed

    Samadi, Sediqeh; Rashid, Mudassir; Turksoy, Kamuran; Feng, Jianyuan; Hajizadeh, Iman; Hobbs, Nicole; Lazaro, Caterina; Sevil, Mert; Littlejohn, Elizabeth; Cinar, Ali

    2018-03-01

    Automatically attenuating the postprandial rise in the blood glucose concentration without manual meal announcement is a significant challenge for artificial pancreas (AP) systems. In this study, a meal module is proposed to detect the consumption of a meal and to estimate the amount of carbohydrate (CHO) intake. The meals are detected based on qualitative variables describing variation of continuous glucose monitoring (CGM) readings. The CHO content of the meals/snacks is estimated by a fuzzy system using CGM and subcutaneous insulin delivery data. The meal bolus amount is computed according to the patient's insulin to CHO ratio. Integration of the meal module into a multivariable AP system allows revision of estimated CHO based on knowledge about physical activity, sleep, and the risk of hypoglycemia before the final decision for a meal bolus is made. The algorithm is evaluated by using 117 meals/snacks in retrospective data from 11 subjects with type 1 diabetes. Sensitivity, defined as the percentage of correctly detected meals and snacks, is 93.5% for meals and 68.0% for snacks. The percentage of false positives, defined as the proportion of false detections relative to the total number of detected meals and snacks, is 20.8%. Integration of a meal detection module in an AP system is a further step toward an automated AP without manual entries. Detection of a consumed meal/snack and infusion of insulin boluses using an estimate of CHO enables the AP system to automatically prevent postprandial hyperglycemia.

  16. Interaction of dipalmitoyl phosphatidylcholine (DPPC) liposomes and insulin

    NASA Astrophysics Data System (ADS)

    Mady, Mohsen M.; Elshemey, Wael M.

    2011-06-01

    Insulin, a peptide that has been used for decades in the treatment of diabetes, has well-defined properties and delivery requirements. Liposomes, which are lipid bilayer vesicles, have gained increasing attention as drug carriers which reduce the toxicity and increase the pharmacological activity of various drugs. The molecular interaction between (uncharged lipid) dipalmitoyl phosphatidylcholine (DPPC) liposomes and insulin has been characterized by using Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction. The characteristic protein absorption band peaks, Amide I (at about 1660 cm-1) and Amide II band (at about 1546 cm-1) are potentially reduced in the liposome insulin complex. Wide-angle x-ray scattering measurements showed that the association of insulin with DPPC lipid of liposomes still maintains the characteristic DPPC diffraction peaks with almost no change in relative intensities or change in peak positions. The absence of any shift in protein peak positions after insulin being associated with DPPC liposomes indicates that insulin is successfully forming complex with DPPC liposomes with possibly no pronounced alterations in the structure of insulin molecule.

  17. Daily insulin requirement of children and adolescents with type 1 diabetes: effect of age, gender, body mass index and mode of therapy.

    PubMed

    Wiegand, Susanna; Raile, Klemens; Reinehr, Thomas; Hofer, Sabine; Näke, Andrea; Rabl, Wolfgang; Holl, Reinhard W

    2008-04-01

    The purpose of this study was to generate insulin dose (ID) percentiles for children and adolescents with type 1 diabetes mellitus (DM1) having the opportunity to assess this important parameter in relation to age and sex. Daily IDs per weight (ID/kg) were recorded in 22,177 patients with DM1 (3-25 years of age, DM1 duration of more than 2 years, 48% female) and ID percentiles (ID-Perc) were created statistically. The ID-Perc were compared between male and female, and between multiple insulin injection therapy (MIT) and continuous s.c. insulin infusion (CSII). A multivariate regression analysis was performed for ID in the third year of DM1 with ID/kg, body weight, age, gender, and insulin delivery regimen as variables. The 50th ID-Perc (P50) varied among 0.67 IU/kg (age 3 years), 0.93 IU/kg (13 years), and 0.70 IU/kg (23 years) increasing from early childhood to adolescence and decreasing toward adulthood. Highest P50 ID was found at 12 years in females (0.94 IU/kg) and at 14 years in males (0.92 IU/kg). Using ICT, the ID was significantly higher compared with CSII (P50: 0.94 IU/kg versus 0.79 IU/kg at 13 years). In multivariate regression analysis, ID was significantly (P>0.001) associated with age, gender, and insulin delivery regime. The ID-Perc were significantly different during various periods of childhood and were influenced by gender, body weight, and insulin injection regimes. Therefore, the presented data 1) provide evidence to interpret individual ID in children and adolescents with DM1 and 2) more specifically identify children with unusually high (insulin resistance and non-compliance) or low (MODY and persistent remission) insulin requirement.

  18. Protein delivery with infusion pumps.

    PubMed

    Bremer, U; Horres, C R; Francoeur, M L

    1997-01-01

    When a therapeutic effect is optimized by precise control of specific temporal patterns of plasma levels, infusion offers distinct advantages over oral administration, bolus injection, or depot delivery of polypeptides. The limitations of oral delivery are well known, and although research is under way into development of carrier systems that prevent degradation of labile agents, it is unlikely that the variances in absorption will meet the need for precise control. Depot delivery from subcutaneous or intramuscular implants presents a difficult situation when local tissue reactions to the agent sometimes occur. Removal of a depot system in the event of adverse reactions presents additional difficulties. Bolus injections are unable to sustain constant plasma levels unless the drug half-life is long or the injections are frequently administered. Insulin injections, for example, would be required every 30-60 minutes to approximate the plasma levels provided by a continuous infusion; such frequent injections would not be practical on a 24-hour basis. For the developer of new polypeptides, parenteral administration offers the most direct route to the marketplace. The step from periodic injections to tightly controlled infusion is a logical progression as compared with modification of the molecules or vehicles to obtain equivalent profiles. In Table II several different types of devices that can be used for infusion of proteins are compared. Microelectronics have played a major role in the miniaturization of infusion devices and undoubtedly will continue to do so. Micromachining, a spin-off technology of integrated circuit manufacture, will also find application in small infusion devices. In the future, we will have cost-effective disposable devices (Saaman et al., 1994) built on this technology that are programmable and thus can be adapted to meet each individual therapeutic need (Horres, 1994). We can also expect to see more closed-loop drug delivery systems where biosensors and infusion devices are combined to optimize a particular therapy. Recent positive results obtained in diabetics by a decade on tight glucose control may forecast a resurgence of popularity of insulin pumps. At the other end of the spectrum, low-cost, small, and simple-to-use osmotically powered systems are close to being marketed; these systems will make infusion almost as convenient as transdermal patches. We will also see major advances in how drugs and devices are interfaced. Prefilled and ready-to-use drug cartridges have proven to be efficient in surgical and emergency medicine and can greatly improve most infusion applications. It is anticipated that coded, prefilled cartridges or pouches will be automatically, recognized by preprogrammed pumps to reduce operator labor and entry error.

  19. Microneedles for intradermal and transdermal delivery

    PubMed Central

    Tuan-Mahmood, Tuan-Mazlelaa; McCrudden, Maeliosa T.C.; Torrisi, Barbara M.; McAlister, Emma; Garland, Martin J; Singh, Thakur Raghu Raj; Donnelly, Ryan F

    2014-01-01

    The formidable barrier properties of the uppermost layer of the skin, the stratum corneum impose significant limitations for successful systemic delivery of a broad range of therapeutic molecules, particularly macromolecules and genetic material. Microneedle delivery has been proposed as a strategy to breach the SC barrier function in order to facilitate effective transport of molecules across the skin. This strategy involves the use of micron sized needles fabricated from different materials and using different geometries to create transient aqueous conduits across the skin. Microneedles in isolation, or in combination with other enhancing strategies, have been shown to dramatically enhance the skin permeability of numerous therapeutic molecules including biopharmaceuticals either in vitro, ex vivo or in vivo. Progress in the areas of microneedle design, development and manufacture have proven promising in terms of the potential use of this emerging delivery method in clinical applications such as insulin delivery, transcutaneous immunisations and cutaneous gene delivery. This review article focuses on recent and potential future developments in microneedle technologies. This will include the detailing of progress made in microneedle design, an exploration of the challenges faced in this field and potential forward strategies to embrace the exploitation of microneedle methodologies, while considering the inherent safety aspects of such therapeutic tools. PMID:23680534

  20. [D-Leu-4]-OB3, a synthetic peptide amide with leptin-like activity, augments the effects of orally delivered exenatide and pramlintide acetate on energy balance and glycemic control in insulin-resistant male C57BLK/6-m db/db mice.

    PubMed

    Leinung, Matthew C; Grasso, Patricia

    2012-11-10

    The escalation predicted for the incidence of both type 2 diabetes mellitus and obesity has prompted investigators to search for additional pharmacotherapeutic approaches to their treatment. Two of these approaches, combination pharmacotherapy and utilization of leptin-related bioactive synthetic peptides as anti-diabetes/anti-obesity agents, were used in the present study. Exenatide or pramlintide acetate was reconstituted in dodecyl maltoside (DDM) in the absence or presence of [D-Leu-4]-OB3, and delivered orally by gavage to insulin-resistant male C57BLK/6-m db/db mice twice daily for 14 days. Body weight gain, food and water intake, blood glucose, and serum insulin levels were measured. Mice given DDM alone for 14 days were 19.7% heavier than they were at the beginning of the study, while oral delivery of exenatide or [D-Leu-4]-OB3 in DDM reduced body weight gain to only 13.9% and 11.5%, respectively, of initial body weight. Mice receiving exenatide and [D-Leu-4]-OB3 were 4.2% lighter than they were at the beginning of the study. In another study, Intravail® treated control mice gained 38.2% of their initial body weight, while mice receiving pramlintide acetate or [D-Leu-4]-OB3 were only 26.8% and 25.4% heavier, respectively, at the end of the study, Co-administration of pramlintide acetate and [D-Leu-4]-OB3 did not further enhance the effect of pramlintide acetate on body weight gain. Food intake was reduced by exenatide, pramlintide acetate, and [D-Leu-4]-OB3 alone, and co-delivery with [D-Leu-4]-OB3 did not induce a further decrease. Water intake was not affected by exenatide, pramlintide acetate, or [D-Leu-4]-OB3 alone, but co-delivery of exenatide or pramlintide acetate with [D-Leu-4]-OB3 resulted in a significant reduction in water intake. Oral delivery of exenatide or pramlintide acetate in DDM significantly lowered blood glucose levels by 20.4% and 30.2%, respectively. Co-delivery with [D-Leu-4]-OB3 further reduced blood glucose by 38.3% and 50.5%, respectively. A concentration-dependent increase in serum insulin was observed in response to increasing concentrations of exenatide, and [D-Leu-4]-OB3 slightly reduced the insulin response to exenatide at all concentrations tested. Increasing concentrations of pramlintide acetate alone did not elevate serum insulin, and when given in combination with [D-Leu-4]-OB3, serum insulin levels fell below those of DDM-treated control mice. Our data indicate that (1) exenatide and pramlintide acetate, currently administered by subcutaneous injection, can be given orally in DDM; (2) the bioactivity of exenatide and pramlintide acetate is retained following oral delivery in DDM; and (3) the effects of exenatide and pramlintide acetate on energy balance and glycemic control can be enhanced by co-administration with [D-Leu-4]-OB3, a synthetic peptide amide with leptin-like activity. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Synthesis of poly(N-isopropylacrylamide)-co-poly(phenylboronate ester) acrylate and study on their glucose-responsive behavior.

    PubMed

    Yao, Yuan; Shen, Heyun; Zhang, Guanghui; Yang, Jing; Jin, Xu

    2014-10-01

    We introduced thermo-sensitive poly(N-isopropylacrylamide) (PNIPAM) into the polymer structure of poly(ethylene glycol)-block-poly(phenylboronate ester) acrylate (MPEG-block-PPBDEMA) by block and random polymerization pathways in order to investigate the effect of polymer architecture on the glucose-responsiveness and enhance their insulin release controllability. By following the structure, the continuous PNIPAM shell of the triblock polymer MPEG-block-PNIPAM-block-PPBDEMA collapsing on the glucose-responsive PPBDEMA core formed the polymeric micelles with a core-shell-corona structure, and MPEG-block-(PNIPAM-rand-PPBDEMA) exhibited core-corona micelles in which the hydrophobic core consisted of PNIPAM and PPBDEMA segments when the environmental temperature was increased above low critical solution temperature (LCST) of PNIPAM. The micellar morphologies can be precisely controlled by temperature change between 15 and 37°C. As a result, the introduction of PNIPAM greatly enhanced the overall stability of insulin encapsulated in the polymeric micelles in the absence of glucose over incubation 80 h at 37°C. Comparing to MPEG-block-PNIPAM-block-PPBDEMA, the nanocarriers from MPEG-block-(PNIPAM-rand-PPBDEMA) showed great insulin release behavior which is zero insulin release without glucose, low release at normal blood glucose concentration (1.0 mg/mL). Therefore, these nanocarriers may be served as promising self-regulated insulin delivery system for diabetes treatment. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Position Statement on the management of continuous subcutaneous insulin infusion (CSII): The Italian Lazio experience.

    PubMed

    Maurizi, Anna R; Suraci, Concetta; Pitocco, Dario; Schiaffini, Riccardo; Tubili, Claudio; Morviducci, Lelio; Giordano, Renato; Manfrini, Silvia; Lauro, Davide; Frontoni, Simona; Pozzilli, Paolo; Buzzetti, Raffaella

    2016-01-01

    This document has been developed by a group of Italian diabetologists with extensive experience in continuous subcutaneous insulin infusion (CSII) therapy to provide indications for the clinical management of CSII in diabetic patients (both type 1 and type 2) based on delivery mode operating in Italy. Although the potential benefits of pump therapy in achieving glycemic goals is now accepted, such results cannot be obtained without specific knowledge and skills being conveyed to patients during ad hoc educational training. To ensure that these new technologies reach their full effectiveness, as demonstrated theoretically and clinically, a careful assessment of the overall therapeutic and educational process is required, in both qualitative and quantitative terms. Therefore, to ensure the cost-effectiveness of insulin pump therapy and to justify reimbursement of therapy costs by the National Health System in Italy, in this article we present a model for diabetes and healthcare centers to follow that provides for different levels of expertise in the field of CSII therapy. This model will guarantee the provision of excellent care during insulin pump therapies, thus representing the basis for a successful outcome and expansion of this form of insulin treatment in patients with diabetes while also keeping costs under control. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  3. Intraarterial Microdosing, a Novel Drug Development Approach, Proof-of-Concept PET Study in Rats

    PubMed Central

    Burt, Tal; Rouse, Douglas C.; Lee, Kihak; Wu, Huali; Layton, Anita T.; Hawk, Thomas C.; Weitzel, Douglas H.; Chin, Bennett B.; Cohen-Wolkowiez, Michael; Chow, Shein-Chung; Noveck, Robert J.

    2016-01-01

    Intraarterial microdosing (IAM) is a novel drug development approach combining intraarterial drug delivery and microdosing. We aimed to demonstrate that IAM leads to target exposure similar to that of systemic full-dose administration but with minimal systemic exposure. IAM could enable the safe, inexpensive, and early study of novel drugs at the first-in-human stage and the study of established drugs in vulnerable populations. Methods Insulin was administered intraarterially (ipsilateral femoral artery) or systemically to 8 CD IGS rats just before blood sampling or 60-min 18F-FDG uptake PET imaging of ipsilateral and contralateral leg muscles (lateral gastrocnemius) and systemic muscles (spinotrapezius). The 18F-FDG uptake slope analysis was used to compare the interventions. Plasma levels of insulin and glucose were compared using area under the curve calculated by the linear trapezoidal method. A physiologically based computational pharmacokinetics/pharmacodynamics model was constructed to simulate the relationship between the administered dose and response over time. Results 18F-FDG slope analysis found no difference between IAM and systemic full-dose slopes (0.0066 and 0.0061, respectively; 95% confidence interval [CI], −0.024 to 0.029; P = 0.7895), but IAM slope was statistically significantly greater than systemic microdose (0.0018; 95% CI, −0.045 to −0.007; P = 0.0147) and sham intervention (−0.0015; 95% CI, 0.023–0.058; P = 0.0052). The pharmacokinetics/pharmacodynamics data were used to identify model parameters that describe membrane insulin binding and glucose–insulin dynamics. Conclusion Target exposure after IAM was similar to systemic full dose administration but with minimal systemic effects. The computational pharmacokinetics/pharmacodynamics model can be generalized to predict whole-body response. Findings should be validated in larger, controlled studies in animals and humans using a range of targets and classes of drugs. PMID:26315828

  4. Subcutaneous insulin therapy - end of the road after 80 years?

    PubMed

    Leifke, E; Strack, T R

    2014-02-01

    Subcutaneous (SC) insulin therapy has been a mainstay of pharmacological diabetes management from the moment insulin was successfully developed as treatment. Insulin formulations have become more refined and less allergenic over time, and ancillary technologies such as injection devices and glucose measurement tools have evolved to the extent of permitting closed-loop therapy. However, investigations have continued exploring alternative routes of administration with the ultimate goal of implantable islet replacements, whether cell- or "silicon"-based. Progress on these lines of research, however, has been slow to present patients with viable options: alternative delivery routes have failed to deliver insulin reliably and with commercially viable efficiency, while beta cell transplantation continues to struggle with tissue availability and in vivo viability. In the meantime, SC insulin formulations have advanced for rapid- and long-acting formulations, to better meet typical insulin requirements across the day. Thus, SC insulin will likely remain a key technology for the foreseeable future in order to address the needs of an ever larger number of insulin-dependent patients with diabetes. Copyright 2014 Prous Science, S.A.U. or its licensors. All rights reserved.

  5. Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens.

    PubMed

    Klonoff, David; Nayberg, Irina; Thonius, Marissa; See, Florian; Abdel-Tawab, Mona; Erbstein, Frank; Haak, Thomas

    2015-08-26

    To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™. For the accuracy assessment, 60 of each of the 3 tested devices were used for the delivery of 3 different doses (1 U, half-maximal dose, and maximal dose), which were measured gravimetrically. For the injection force assessment, 20 pens of each of the 3 types were tested twice at half-maximal and once at maximal dose, at an injection speed of 6 U/s. All tested pens met the International Organization for Standardization (ISO) requirements for dosing accuracy, with Gla-300 SoloSTAR showing the lowest between-dose variation (greatest reproducibility) at all dose levels. Mean injection force was significantly lower for Gla-300 SoloSTAR than for the other 2 pens at both half maximal and maximal doses (P < .0271). All tested pens were accurate according to ISO criteria, and the Gla-300 SoloSTAR pen displayed the greatest reproducibility and lowest injection force of any of the 3 tested devices. © 2015 Diabetes Technology Society.

  6. Asymptotic tracking and disturbance rejection of the blood glucose regulation system.

    PubMed

    Ashley, Brandon; Liu, Weijiu

    2017-07-01

    Type 1 diabetes patients need external insulin to maintain blood glucose within a narrow range from 65 to 108 mg/dl (3.6 to 6.0 mmol/l). A mathematical model for the blood glucose regulation is required for integrating a glucose monitoring system into insulin pump technology to form a closed-loop insulin delivery system on the feedback of the blood glucose, the so-called "artificial pancreas". The objective of this paper is to treat the exogenous glucose from food as a glucose disturbance and then develop a closed-loop feedback and feedforward control system for the blood glucose regulation system subject to the exogenous glucose disturbance. For this, a mathematical model for the glucose disturbance is proposed on the basis of experimental data, and then incorporated into an existing blood glucose regulation model. Because all the eigenvalues of the disturbance model have zero real parts, the center manifold theory is used to establish blood glucose regulator equations. We then use their solutions to synthesize a required feedback and feedforward controller to reject the disturbance and asymptotically track a constant glucose reference of 90  mg/dl. Since the regulator equations are nonlinear partial differential equations and usually impossible to solve analytically, a linear approximation solution is obtained. Our numerical simulations show that, under the linear approximate feedback and feedforward controller, the blood glucose asymptotically tracks its desired level of 90 mg/dl approximately. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Glucose sensing in the peritoneal space offers faster kinetics than sensing in the subcutaneous space.

    PubMed

    Burnett, Daniel R; Huyett, Lauren M; Zisser, Howard C; Doyle, Francis J; Mensh, Brett D

    2014-07-01

    The paramount goal in the treatment of type 1 diabetes is the maintenance of normoglycemia. Continuous glucose monitoring (CGM) technologies enable frequent sensing of glucose to inform exogenous insulin delivery timing and dosages. The most commonly available CGMs are limited by the physiology of the subcutaneous space in which they reside. The very same advantages of this minimally invasive approach are disadvantages with respect to speed. Because subcutaneous blood flow is sensitive to local fluctuations (e.g., temperature, mechanical pressure), subcutaneous sensing can be slow and variable. We propose the use of a more central, physiologically stable body space for CGM: the intraperitoneal space. We compared the temporal response characteristics of simultaneously placed subcutaneous and intraperitoneal sensors during intravenous glucose tolerance tests in eight swine. Using compartmental modeling based on simultaneous intravenous sensing, blood draws, and intraarterial sensing, we found that intraperitoneal kinetics were more than twice as fast as subcutaneous kinetics (mean time constant of 5.6 min for intraperitoneal vs. 12.4 min for subcutaneous). Combined with the known faster kinetics of intraperitoneal insulin delivery over subcutaneous delivery, our findings suggest that artificial pancreas technologies may be optimized by sensing glucose and delivering insulin in the intraperitoneal space. © 2014 by the American Diabetes Association.

  8. Glucose Sensing in the Peritoneal Space Offers Faster Kinetics Than Sensing in the Subcutaneous Space

    PubMed Central

    Burnett, Daniel R.; Huyett, Lauren M.; Zisser, Howard C.; Doyle, Francis J.

    2014-01-01

    The paramount goal in the treatment of type 1 diabetes is the maintenance of normoglycemia. Continuous glucose monitoring (CGM) technologies enable frequent sensing of glucose to inform exogenous insulin delivery timing and dosages. The most commonly available CGMs are limited by the physiology of the subcutaneous space in which they reside. The very same advantages of this minimally invasive approach are disadvantages with respect to speed. Because subcutaneous blood flow is sensitive to local fluctuations (e.g., temperature, mechanical pressure), subcutaneous sensing can be slow and variable. We propose the use of a more central, physiologically stable body space for CGM: the intraperitoneal space. We compared the temporal response characteristics of simultaneously placed subcutaneous and intraperitoneal sensors during intravenous glucose tolerance tests in eight swine. Using compartmental modeling based on simultaneous intravenous sensing, blood draws, and intraarterial sensing, we found that intraperitoneal kinetics were more than twice as fast as subcutaneous kinetics (mean time constant of 5.6 min for intraperitoneal vs. 12.4 min for subcutaneous). Combined with the known faster kinetics of intraperitoneal insulin delivery over subcutaneous delivery, our findings suggest that artificial pancreas technologies may be optimized by sensing glucose and delivering insulin in the intraperitoneal space. PMID:24622798

  9. Predictors of Hypoglycemia in the ASPIRE In-Home Study and Effects of Automatic Suspension of Insulin Delivery.

    PubMed

    Weiss, Ram; Garg, Satish K; Bergenstal, Richard M; Klonoff, David C; Bode, Bruce W; Bailey, Timothy S; Thrasher, James; Schwartz, Frank; Welsh, John B; Kaufman, Francine R

    2015-05-18

    Hypoglycemia varies between patients with type 1 diabetes and is the main obstacle to therapy intensification. We investigated known and potential risk factors for hypoglycemia in subjects with type 1 diabetes. In the ASPIRE In-Home study (NCT01497938), a randomized trial of the threshold suspend (TS) feature of sensor-augmented insulin pump (SAP) therapy, subjects' propensity to nocturnal hypoglycemia (NH) was established in a 2-week run-in phase and assessed in a 3-month study phase via continuous glucose monitoring. Categorical variables were tested for association with NH rates in both phases. Elevated rates of NH were significantly associated with baseline A1C ≤7%, with bolus insulin deliveries unassisted by the bolus estimation calculator, and with assignment to the control group during the study phase. Routine use of the TS feature and the bolus estimation calculator are strategies that may reduce the risk of NH. © 2015 Diabetes Technology Society.

  10. Insulin during pregnancy, labour and delivery.

    PubMed

    de Valk, Harold W; Visser, Gerard H A

    2011-02-01

    Optimal glycaemic control is of the utmost importance to achieve the best possible outcome of a pregnancy complicated by diabetes. This holds for pregnancies in women with preconceptional type 1 or type 2 diabetes as well as for pregnancies complicated by gestational diabetes. Glycaemic control is conventionally expressed in the HbA1c value but the HbA1c value does not completely capture the complexity of glycaemic control. The daily glucose profile measured by the patients themselves through measurements performed in capillary blood obtained by finger stick provides valuable information needed to adjust insulin therapy. Hypoglycaemia is the major threat to the pregnant woman or the woman with tight glycaemic control in the run-up to pregnancy. Repetitive hypoglycaemia can lead to hypoglycaemia unawareness, which is reversible with prevention of hypoglycaemia. A delicate balance should be struck between preventing hyperglycaemia and hypoglycaemia. Insulin requirements are not uniform across the day: it is low during the night with a more or less pronounced rise at dawn, followed by a gradual decrease during the remainder of the day. A basal amount of insulin is needed to regulate the endogenous glucose production, short-acting insulin shots are needed to handle exogenous glucose loads. Insulin therapy means two choices: the type of insulin used and the method of insulin administration. Regarding the type of insulin, the choice is between human and analogue insulins. The analogue short-acting insulin aspart has been shown to be safe during pregnancy in a randomised trial and has received registration for this indication; the short-acting analogue insulin lispro has been shown to be safe in observational studies. No such information is available on the long-acting insulin analogues detemir and glargine and both are prescribed off-label with human long-acting insulin as obvious alternatives. Randomised trials have not been able to show superiority of continuous subcutaneous insulin administration (CSII (insulin pump)) over intensive insulin injection therapy (multiple-dose insulin (MDI)) on any maternal or foeto-neonatal end point. However, group sizes were far too small to allow assessment of superiority and issues such as manageability of the disease and quality of life were never assessed. These two issues are of major importance to patients. The first trimester is often the period of most hypoglycaemic events, and insulin therapy should be especially closely monitored and adjusted in this period. After midterm, insulin requirements increase. Continuous glucose monitoring can offer better insights into the glycaemic profile than self-monitoring of blood glucose levels by the patients but the place of these new monitoring techniques has yet to be established more clearly. Insulin therapy during labour means short-acting insulin adjusted to achieve glucose levels between 4 and 8 mmol l(-1) to prevent neonatal hypoglycaemia as much as possible. After delivery, glycaemic control must be relaxed to prevent hypoglycaemia, especially in women who breastfeed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Vascularization and Cellular Isolation Potential of a Novel Electrospun Cell Delivery Vehicle

    PubMed Central

    Krishnan, Laxminarayanan; Touroo, Jeremy; Reed, Robert; Boland, Eugene; Hoying, James B.; Williams, Stuart K.

    2014-01-01

    A clinical need exists for a cell delivery device that supports long term cell viability, cell retention within the device and retrieval of delivered cells if necessary. Previously, cell isolation devices have been based on hollow fiber membranes, porous polymer scaffolds, alginate systems, or micro-machined membranes. We present the development and characterization of a novel dual porosity electrospun membrane based device, which supports cellular infiltration and vascularization of its outer porous layer and maintains cellular isolation within a lumen bounded by an inner low porosity layer. Electrospinning conditions were initially established to support electrospun fiber deposition onto nonconductive silicone surfaces. With these parameters established, devices for in vivo evaluations were produced using nylon as a nonconductive scaffold for deposition of dual porosity electrospun fibers. The outer porous layer supported the development of a penetrating microcirculation and the membrane supported the transfer of insulin from encapsulated sustained release pellets for four weeks. Viable cells implanted within the device could be identified after two weeks of implantation. Through the successful demonstration of survival and cellular isolation of human epithelial cells within the implanted devices and the ability to use the device to deliver insulin, we have established the utility of this device toward localized cell transplantation. The Cell Delivery Device establishes a platform to test the feasibility of approaches to cell dose control and cell localization at the site of implantation in the clinical use of modified autologous or allogeneic cells. PMID:23913805

  12. Dissolving polymeric microneedle arrays for electrically assisted transdermal drug delivery.

    PubMed

    Garland, Martin J; Caffarel-Salvador, Ester; Migalska, Katarzyna; Woolfson, A David; Donnelly, Ryan F

    2012-04-10

    It has recently been proposed that the combination of skin barrier impairment using microneedles (MNs) coupled with iontophoresis (ITP) may broaden the range of drugs suitable for transdermal delivery, as well as enabling the rate of delivery to be achieved with precise electronic control. However, no reports exist on the combination of ITP with in situ drug loaded polymeric MN delivery systems. Furthermore, although a number of studies have highlighted the importance of MN design for transdermal drug delivery enhancement, to date, there has been no systematic investigation of the influence of MN geometry on the performance of polymeric MN arrays which are designed to remain in contact with the skin during the period of drug delivery. As such, for the first time, this study reports on the effect of MN heigth and MN density upon the transdermal delivery of small hydrophilic compounds (theophylline, methylene blue, and fluorescein sodium) across neonatal porcine skin in vitro, with the optimised MN array design evaluated for its potential in the electrically faciliatated delivery of peptide (bovine insulin) and protein (fluorescein isothiocyanate-labelled bovine serum albumin (FTIC-BSA)) macromolecules. The results of the in vitro drug release investigations revealed that the extent of transdermal delivery was dependent upon the design of the MN array employed, whereby an increase in MN height and an increase in MN density led to an increase in the extent of transdermal drug delivery achieved 6h after MN application. Overall, the in vitro permeation studies revealed that the MN design containing 361 MNs/cm(2) of 600 μm height resulted in the greatest extent of transdermal drug delivery. As such, this design was evaluated for its potential in the MN mediated iontophoretic transdermal delivery. Whilst the combination of MN and ITP did not further enhance the extent of small molecular weight solute delivery, the extent of peptide/protein release was significantly enhanced when ITP was used in combination of the soluble PMVE/MA MN arrays. For example, the cumulative amount of insulin permeated across neonatal porcine skin at 6h was found to be approximately 150 μg (3.25%), 227 μg (4.85%) and 462 μg (9.87%) for ITP, MN, and MN/ITP delivery strategies, respectively. Similarly, the cumulative amount of FTIC-BSA delivered across neonatal porcine skin after a 6h period was found to be approximately 110 μg (4.53%) for MN alone and 326 μg (13.40%) for MN in combination with anodal ITP (p<0.001). As such, drug loaded soluble PMVE/MA MN arrays show promise for the electrically controlled transdermal delivery of biomacromolecules in a simple, one-step approach. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Promoting effects of chemical permeation enhancers on insulin permeation across TR146 cell model of buccal epithelium in vitro.

    PubMed

    Xue, Xiao-yan; Zhou, Ying; Chen, Ying-ying; Meng, Jing-ru; Jia, Min; Hou, Zheng; Bai, Hui; Mao, Xing-gang; Luo, Xiao-xing

    2012-04-01

    To find potential enhancers for facilitating the buccal delivery of insulin, a TR146 cell-culture model of buccal epithelium, cultured on commercially available insert plates, was used to evaluate the permeability-enhancing effects of several traditional and new types of chemical enhancers, including N-acetyl-L-cysteine (NAC), sodium deoxycholate (SDC), sodium nitroprusside (SNP), reduced glutathione (GSH), glutamine (Gln), chitosan (CS), L-arginine (Arg), 1-dodecylazacycloheptan-2-one (Azone), and soybean lecithin (SPC) (50 and 10 μg/mL respectively). Permeability studies were performed to determine the enhancing effects of these compounds on insulin permeation across the cell-culture model. The enhancing effects of the enhancers were assessed by calculating the apparent permeability coefficients and enhancement ratio. Cytotoxicity of the permeation enhancers at different concentrations was investigated by using the methylthiazolydiphenyl-tetrazolium bromide (MTT) assay. Results showed that 50 μg/mL of NAC, SDC, GSH, CS, Arg, Azone, SPC, SNP, and 10 μg/mL of SNP had a significant enhancing effect on promoting the transport of insulin across the TR146 cell model. MTT assays showed that 50 μg/mL of Gln, Azone, SDC, SNP, Arg, 10 μg/mL SDC, and Arg had obvious toxic effects on TR146 cells. Therefore, NAC, GSH, CS, SPC, and SNP appear to be safe, effective permeability enhancers that promote the transport of insulin across the TR146 cell-culture model of buccal epithelium and may be potential enhancers for buccal delivery of insulin with both low toxicity and high efficiency.

  14. Intranasal insulin protects against substantia nigra dopaminergic neuronal loss and alleviates motor deficits induced by 6-OHDA in rats.

    PubMed

    Pang, Y; Lin, S; Wright, C; Shen, J; Carter, K; Bhatt, A; Fan, L-W

    2016-03-24

    Protection of substantia nigra (SN) dopaminergic (DA) neurons by neurotrophic factors (NTFs) is one of the promising strategies in Parkinson's disease (PD) therapy. A major clinical challenge for NTF-based therapy is that NTFs need to be delivered into the brain via invasive means, which often shows limited delivery efficiency. The nose to brain pathway is a non-invasive brain drug delivery approach developed in recent years. Of particular interest is the finding that intranasal insulin improves cognitive functions in Alzheimer's patients. In vitro, insulin has been shown to protect neurons against various insults. Therefore, the current study was designed to test whether intranasal insulin could afford neuroprotection in the 6-hydroxydopamine (6-OHDA)-based rat PD model. 6-OHDA was injected into the right side of striatum to induce a progressive DA neuronal lesion in the ipsilateral SN pars compact (SNc). Recombinant human insulin was applied intranasally to rats starting from 24h post lesion, once per day, for 2 weeks. A battery of motor behavioral tests was conducted on day 8 and 15. The number of DA neurons in the SNc was estimated by stereological counting. Our results showed that 6-OHDA injection led to significant motor deficits and 53% of DA neuron loss in the ipsilateral side of injection. Treatment with insulin significantly ameliorated 6-OHDA-induced motor impairments, as shown by improved locomotor activity, tapered/ledged beam-walking performance, vibrissa-elicited forelimb-placing, initial steps, as well as methamphetamine-induced rotational behavior. Consistent with behavioral improvements, insulin treatment provided a potent protection of DA neurons in the SNc against 6-OHDA neurotoxicity, as shown by a 74.8% increase in tyrosine hydroxylase (TH)-positive neurons compared to the vehicle group. Intranasal insulin treatment did not affect body weight and blood glucose levels. In conclusion, our study showed that intranasal insulin provided strong neuroprotection in the 6-OHDA rat PD model, suggesting that insulin signaling may be a novel therapeutic target in broad neurodegenerative disorders. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  15. Lyophilized insulin nanoparticles prepared from quaternized N-aryl derivatives of chitosan as a new strategy for oral delivery of insulin: in vitro, ex vivo and in vivo characterizations.

    PubMed

    Mahjub, Reza; Radmehr, Moojan; Dorkoosh, Farid Abedin; Ostad, Seyed Naser; Rafiee-Tehrani, Morteza

    2014-12-01

    The purpose of this research was the development, in vitro, ex vivo and in vivo characterization of lyophilized insulin nanoparticles prepared from quaternized N-aryl derivatives of chitosan. Insulin nanoparticles were prepared from methylated N-(4-N,N-dimethylaminobenzyl), methylated N-(4 pyridinyl) and methylated N-(benzyl). Insulin nanoparticles containing non-modified chitosan and also trimethyl chiotsan (TMC) were also prepared as control. The effects of the freeze-drying process on physico-chemical properties of nanoparticles were investigated. The release of insulin from the nanoparticles was studied in vitro. The mechanism of the release of insulin from different types of nanoparticles was determined using curve fitting. The secondary structure of the insulin released from the nanoparticles was analyzed using circular dichroism and the cell cytotoxicity of nanoparticles on a Caco-2 cell line was determined. Ex vivo studies were performed on excised rat jejunum using Frantz diffusion cells. In vivo studies were performed on diabetic male Wistar rats and blood glucose level and insulin serum concentration were determined. Optimized nanoparticles with proper physico-chemical properties were obtained. The lyophilization process was found to cause a decrease in zeta potential and an increase in PdI as well as and a decrease in entrapment efficiency (EE%) and loading efficiency (LE%) but conservation in size of nanoparticles. Atomic force microscopy (AFM) images showed non-aggregated, stable and spherical to sub-spherical nanoparticles. The in vitro release study revealed higher release rates for lyophilized compared to non-lyophilized nanoparticles. Cytotoxicity studies on Caco-2 cells revealed no significant cytotoxicity for prepared nanoparticles after 3-h post-incubation but did show the concentration-dependent cytotoxicity after 24 h. The percentage of cumulative insulin determined from ex vivo studies was significantly higher in nanoparticles prepared from quaternized aromatic derivatives of chitosan. In vivo data showed significantly higher insulin intestinal absorption in nanoparticles prepared from methylated N-(4-N, N-dimethylaminobenzyl) chitosan nanoparticles compared to trimethyl chitosan. These data obtained demonstrated that as the result of optimized physico-chemical properties, drug release rate, cytotoxicity profile, ex vivo permeation enhancement and increased in vivo absorption, nanoparticles prepared from N-aryl derivatives of chitosan can be considered as valuable method for the oral delivery of insulin.

  16. Continuous versus bolus tube feeds: Does the modality affect glycemic variability, tube feeding volume, caloric intake, or insulin utilization?

    PubMed

    Evans, David C; Forbes, Rachel; Jones, Christian; Cotterman, Robert; Njoku, Chinedu; Thongrong, Cattleya; Tulman, David; Bergese, Sergio D; Thomas, Sheela; Papadimos, Thomas J; Stawicki, Stanislaw P

    2016-01-01

    Enteral nutrition (EN) is very important to optimizing outcomes in critical illness. Debate exists regarding the best strategy for enteral tube feeding (TF), with concerns that bolus TF (BTF) may increase glycemic variability (GV) but result in fewer nutritional interruptions than continuous TF (CTF). This study examines if there is a difference in GV, insulin usage, TF volume, and caloric delivery among intensive care patients receiving BTF versus CTF. We hypothesize that there are no significant differences between CTF and BTF when comparing the above parameters. Prospective, randomized pilot study of critically ill adult patients undergoing percutaneous endoscopic gastrostomy (PEG) placement for EN was performed between March 1, 2012 and May 15, 2014. Patients were randomized to BTF or CTF. Glucose values, insulin use, TF volume, and calories administered were recorded. Data were organized into 12-h epochs for statistical analyses and GV determination. In addition, time to ≥80% nutritional delivery goal, demographics, Acute Physiology and Chronic Health Evaluation II scores, and TF interruptions were examined. When performing BTF versus CTF assessments, continuous parameters were compared using Mann-Whitney U-test or repeated measures t-test, as appropriate. Categorical data were analyzed using Fisher's exact test. No significant demographic or physiologic differences between the CTF (n = 24) and BTF (n = 26) groups were seen. The immediate post-PEG 12-h epoch showed significantly lower GV and median TF volume for patients in the CTF group. All subsequent epochs (up to 18 days post-PEG) showed no differences in GV, insulin use, TF volume, or caloric intake. Insulin use for both groups increased when comparing the first 24 h post-PEG values to measurements from day 8. There were no differences in TF interruptions, time to ≥80% nutritional delivery goal, or hypoglycemic episodes. This study demonstrated no clinically relevant differences in GV, insulin use, TF volume or caloric intake between BTF and CTF groups. Despite some shortcomings, our data suggest that providers should not feel limited to BTF or CTF because of concerns for GV, time to goal nutrition, insulin use, or caloric intake, and should consider other factors such as resource utilization, ease of administration, and/or institutional/patient characteristics.

  17. Inorganic Nanoporous Membranes for Immunoisolated Cell-Based Drug Delivery

    PubMed Central

    Mendelsohn, Adam; Desai, Tejal

    2014-01-01

    Materials advances enabled by nanotechnology have brought about promising approaches to improve the encapsulation mechanism for immunoisolated cell-based drug delivery. Cell-based drug delivery is a promising treatment for many diseases but has thus far achieved only limited clinical success. Treatment of insulin dependent diabetes mellitus (IDDM) by transplantation of pancreatic β-cells represents the most anticipated application of cell-based drug delivery technology. This review outlines the challenges involved with maintaining transplanted cell viability and discusses how inorganic nanoporous membranes may be useful in achieving clinical success. PMID:20384222

  18. The role of new technologies in treating children and adolescents with type 1 diabetes mellitus.

    PubMed

    Shalitin, S; Phillip, M

    2007-10-01

    Given the physiological and psychological impact of type 1 diabetes in children and adolescents, these patients present special challenges to pediatric health care providers. The goals of intensive management of diabetes have been clearly established since the publication of the Diabetes Control and Complication Trial (DCCT) in 1993, which demonstrated that tight metabolic control achieved with intensive insulin therapy is superior to conventional treatment in reducing the risk of long-term microvascular complications. Thus, current recommendations mandate that youth with type 1 diabetes should aim to achieve metabolic control as close to normal as possible. However, strict glycemic control is hard to achieve requiring frequent blood glucose measurements and several insulin injections per day, and in addition is associated with an increased risk of severe hypoglycemia. Recurrent episodes of hypoglycemia, especially at young ages, may cause adverse effects on neurocognitive function, may lead to hypoglycemia unawareness, and may be associated with significant emotional morbidity for the child and parents. Since the discovery of insulin in 1921 there has been constant progress in the way patients with type 1 diabetes are treated. The introduction of recombinant insulin and insulin analogs as well as new insulin delivery systems and glucose monitoring devices enhanced the ability of both patients and medical teams to better define the therapeutic goals and to develop more effective therapeutic strategies. Recent advances in devices for insulin administration and glucose monitoring and the introduction of telemedicine are having a profound effect on the lives of youth with type 1 diabetes. This review focuses on the new technologies which have been developed for treating children and adolescents with type 1 diabetes.

  19. Impact of streptozotocin on altering normal glucose homeostasis during insulin testing in diabetic rats compared to normoglycemic rats

    PubMed Central

    Qinna, Nidal A; Badwan, Adnan A

    2015-01-01

    Streptozotocin (STZ) is currently the most used diabetogenic agent in testing insulin and new antidiabetic drugs in animals. Due to the toxic and disruptive nature of STZ on organs, apart from pancreas, involved in preserving the body’s normal glucose homeostasis, this study aims to reassess the action of STZ in inducing different glucose response states in diabetic rats while testing insulin. Diabetic Sprague-Dawley rats induced with STZ were classified according to their initial blood glucose levels into stages. The effect of randomizing rats in such a manner was investigated for the severity of interrupting normal liver, pancreas, and kidney functions. Pharmacokinetic and pharmacodynamic actions of subcutaneously injected insulin in diabetic and nondiabetic rats were compared. Interruption of glucose homeostasis by STZ was challenged by single and repeated administrations of injected insulin and oral glucose to diabetic rats. In diabetic rats with high glucose (451–750 mg/dL), noticeable changes were seen in the liver and kidney functions compared to rats with lower basal glucose levels. Increased serum levels of recombinant human insulin were clearly indicated by a significant increase in the calculated maximum serum concentration and area under the concentration–time curve. Reversion of serum glucose levels to normal levels pre- and postinsulin and oral glucose administrations to STZ diabetic rats were found to be variable. In conclusion, diabetic animals were more responsive to insulin than nondiabetic animals. STZ was capable of inducing different levels of normal glucose homeostasis disruption in rats. Both pharmacokinetic and pharmacodynamic actions of insulin were altered when different initial blood glucose levels of STZ diabetic rats were selected for testing. Such findings emphasize the importance of selecting predefined and unified glucose levels when using STZ as a diabetogenic agent in experimental protocols evaluating new antidiabetic agents and insulin delivery systems. PMID:26005328

  20. Experiences of continuous subcutaneous insulin infusion in pregnant women with type 1 diabetes during delivery from four Italian centers: a retrospective observational study.

    PubMed

    Fresa, Raffaella; Visalli, Natalia; Di Blasi, Vincenzo; Cavallaro, Vincenzo; Ansaldi, Egle; Trifoglio, Oria; Abbruzzese, Santina; Bongiovanni, Marzia; Agrusta, Mariano; Napoli, Angela

    2013-04-01

    An optimized metabolic control during delivery is mandatory to prevent maternal-neonatal complications. The primary aim of this study was to evaluate the efficacy and safety of continuous subcutaneous insulin infusion (CSII) during delivery in pregnant women with type 1 diabetes. The secondary aim was to assess the impact of real-time continuous glucose monitoring (RT-CGM) added to CSII versus CSII alone. This was a multicenter observational retrospective study. A standardized protocol, to use CSII throughout pregnancy and delivery, foresaw three different insulin basal rates according to blood glucose level: profile A, the last basal rate in use; profile B, preventive 50% reduction of the last basal rate in use; and profile C, 0.1-0.2 U/h for blood glucose level <70 mg/dL, activated just before anesthesia or at the beginning of active labor. An alternative intravenous protocol (IVP) was given in case of complications and relevant metabolic deterioration. Blood glucose in the target range (70-140 mg/dL) throughout delivery and percentage of activation of the IVP were primary outcomes. Sixty-five pregnant women with diabetes included in the study (56-86% cesarean section; 9-14% spontaneous/stimulated vaginal delivery). Mean blood glucose level was 102 ± 31 mg/dL at 0 min, 109 ± 42 mg/dL at 30 min, 120 ± 48 mg/dL at 60 min, and 99 ± 34 mg/dL at 24 h. Mean basal rate during delivery was 0.6 ± 0.4 U/h (profile B). Mean capillary blood glucose (CBG) level was lower in the RT-CGM group relative to the CSII-alone group: 80 ± 14 mg/dL versus 111 ± 32 mg/dL at 0 min (P<0.01), 79 ± 11 mg/dL versus 109 ± 42 mg/dL at 30 min (P<0.02), and 98 ± 20 mg/dL versus 125 ± 51 mg/dL at 60 min (difference not significant). Eleven newborns experienced transient neonatal hypoglycemia. None of the women switched to IVP. No major differences were observed according to delivery procedure. CSII is possible and safe in different types of delivery in selected and educated women. RT-CGM helps to obtain better outcomes in terms of maternal peripartum CBG level.

  1. Mitochondrial Dynamics Mediated by Mitofusin 1 Is Required for POMC Neuron Glucose-Sensing and Insulin Release Control.

    PubMed

    Ramírez, Sara; Gómez-Valadés, Alicia G; Schneeberger, Marc; Varela, Luis; Haddad-Tóvolli, Roberta; Altirriba, Jordi; Noguera, Eduard; Drougard, Anne; Flores-Martínez, Álvaro; Imbernón, Mónica; Chivite, Iñigo; Pozo, Macarena; Vidal-Itriago, Andrés; Garcia, Ainhoa; Cervantes, Sara; Gasa, Rosa; Nogueiras, Ruben; Gama-Pérez, Pau; Garcia-Roves, Pablo M; Cano, David A; Knauf, Claude; Servitja, Joan-Marc; Horvath, Tamas L; Gomis, Ramon; Zorzano, Antonio; Claret, Marc

    2017-06-06

    Proopiomelanocortin (POMC) neurons are critical sensors of nutrient availability implicated in energy balance and glucose metabolism control. However, the precise mechanisms underlying nutrient sensing in POMC neurons remain incompletely understood. We show that mitochondrial dynamics mediated by Mitofusin 1 (MFN1) in POMC neurons couple nutrient sensing with systemic glucose metabolism. Mice lacking MFN1 in POMC neurons exhibited defective mitochondrial architecture remodeling and attenuated hypothalamic gene expression programs during the fast-to-fed transition. This loss of mitochondrial flexibility in POMC neurons bidirectionally altered glucose sensing, causing abnormal glucose homeostasis due to defective insulin secretion by pancreatic β cells. Fed mice lacking MFN1 in POMC neurons displayed enhanced hypothalamic mitochondrial oxygen flux and reactive oxygen species generation. Central delivery of antioxidants was able to normalize the phenotype. Collectively, our data posit MFN1-mediated mitochondrial dynamics in POMC neurons as an intrinsic nutrient-sensing mechanism and unveil an unrecognized link between this subset of neurons and insulin release. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Intra‐Target Microdosing – A Novel Drug Development Approach: Proof of Concept, Safety, and Feasibility Study in Humans

    PubMed Central

    MacLeod, D; Lee, K; Santoro, A; DeMasi, DK; Hawk, T; Feinglos, M; Rowland, M; Noveck, RJ

    2017-01-01

    Abstract Intra‐Target Microdosing (ITM) is a novel drug development approach aimed at increasing the efficiency of first‐in‐human (FIH) testing of new molecular entities (NMEs). ITM combines intra‐target drug delivery and “microdosing,” the subpharmacological systemic exposure. We hypothesized that when the target tissue is small (about 1/100th of total body mass), ITM can lead to target therapeutic‐level exposure with minimal (microdose) systemic exposure. Each of five healthy male volunteers received insulin microdose into the radial artery or full therapeutic dose intravenously in separate visits. Insulin and glucose levels were similar between systemic administration and ITM administration in the ipsilateral hand, and glucose levels demonstrated a reduction in the ipsilateral hand but not in the contralateral hand. Positron emission tomography (PET) imaging of 18F‐fluorodeoxyglucose (FDG) uptake demonstrated differences between the ipsilateral and contralateral arms. The procedures were safe and well‐tolerated. Results are consistent with ITM proof‐of‐concept (POC) and demonstrate the ethical, regulatory, and logistical feasibility of the approach. PMID:28689370

  3. Local myocardial insulin-like growth factor 1 (IGF-1) delivery with biotinylated peptide nanofibers improves cell therapy for myocardial infarction

    NASA Astrophysics Data System (ADS)

    Davis, Michael E.; Hsieh, Patrick C. H.; Takahashi, Tomosaburo; Song, Qing; Zhang, Shuguang; Kamm, Roger D.; Grodzinsky, Alan J.; Anversa, Piero; Lee, Richard T.

    2006-05-01

    Strategies for cardiac repair include injection of cells, but these approaches have been hampered by poor cell engraftment, survival, and differentiation. To address these shortcomings for the purpose of improving cardiac function after injury, we designed self-assembling peptide nanofibers for prolonged delivery of insulin-like growth factor 1 (IGF-1), a cardiomyocyte growth and differentiation factor, to the myocardium, using a "biotin sandwich" approach. Biotinylated IGF-1 was complexed with tetravalent streptavidin and then bound to biotinylated self-assembling peptides. This biotin sandwich strategy allowed binding of IGF-1 but did not prevent self-assembly of the peptides into nanofibers within the myocardium. IGF-1 that was bound to peptide nanofibers activated Akt, decreased activation of caspase-3, and increased expression of cardiac troponin I in cardiomyocytes. After injection into rat myocardium, biotinylated nanofibers provided sustained IGF-1 delivery for 28 days, and targeted delivery of IGF-1 in vivo increased activation of Akt in the myocardium. When combined with transplanted cardiomyocytes, IGF-1 delivery by biotinylated nanofibers decreased caspase-3 cleavage by 28% and increased the myocyte cross-sectional area by 25% compared with cells embedded within nanofibers alone or with untethered IGF-1. Finally, cell therapy with IGF-1 delivery by biotinylated nanofibers improved systolic function after experimental myocardial infarction, demonstrating how engineering the local cellular microenvironment can improve cell therapy. engineering | maturation | scaffold

  4. Pulmonary sustained release of insulin from microparticles composed of polyelectrolyte layer-by-layer assembly.

    PubMed

    Amancha, Kiran Prakash; Balkundi, Shantanu; Lvov, Yuri; Hussain, Alamdar

    2014-05-15

    The present study tests the hypothesis that layer-by-layer (LbL) nanoassembly of thin polyelectrolyte films on insulin particles provides sustained release of the drug after pulmonary delivery. LbL insulin microparticles were formulated using cationic and anionic polyelectrolytes. The microparticles were characterized for particle size, particle morphology, zeta potential and in vitro release. The pharmacokinetics and pharmacodynamics of drug were assessed by measuring serum insulin and glucose levels after intrapulmonary administration in rats. Bronchoalveolar lavage (BAL) and evans blue (EB) extravasation studies were performed to investigate the cellular or biochemical changes in the lungs caused by formulation administration. The mass median aerodynamic diameter (MMAD) of the insulin microparticles was 2.7 μm. Confocal image of the formulation particles confirmed the polyelectrolyte deposition around the insulin particles. Zeta potential measurements showed that there was charge reversal after each layering. Pulmonary administered LbL insulin formulation resulted in sustained serum insulin levels and concomitant decrease in serum glucose levels. The BAL and EB extravasation studies showed that the LbL insulin formulation did not elicit significant increase in marker enzymes activities compared to control group. These results demonstrate that the sustained release of insulin could be achieved using LbL nanoassembly around the insulin particles. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. A glucose-sensitive block glycopolymer hydrogel based on dynamic boronic ester bonds for insulin delivery.

    PubMed

    Cai, Baoqi; Luo, Yanping; Guo, Qianqian; Zhang, Xinge; Wu, Zhongming

    2017-06-05

    Hydrogels are good candidates to satisfy many needs for functional and tunable biomaterials. How to precisely control the gel structure and functions is crucial for the construction of sophisticated soft biomaterials comprising the hydrogels, which facilitates the impact of the surrounding environment on a unique biological function occurring. Here, glucose-responsive hydrogels comprised of 3-acrylamidophenyl boronic acid copolymerized with 2-lactobionamidoethyl methacrylate (p(APBA-b-LAMA)) were synthesized, and further evaluated as carriers for insulin delivery. The formation of (p(APBA-b-LAMA)) hydrogel was based on dynamic covalent bond using the association of boronic acid with diols. P(APBA-b-LAMA) hydrogel with the typical porous structure showed a rapid increase in equilibrium of swelling, which was up to 1856% after incubation with aqueous solution. Using insulin as a model protein therapeutic, p(APBA-b-LAMA) hydrogel exhibited high drug loading capability up to 15.6%, and also displayed glucose-dependent insulin release under physiological conditions. Additionally, the viability of NIH3T3 cells was more than 90% after treated with p(APBA-b-LAMA) hydrogel, indicating that the hydrogel had no cytotoxicity. Consequently, the novel p(APBA-b-LAMA) hydrogel has a practical application for diabetes treatment. Copyright © 2017. Published by Elsevier Ltd.

  6. Thermo-responsive human α-elastin self-assembled nanoparticles for protein delivery.

    PubMed

    Kim, Jae Dong; Jung, Youn Jae; Woo, Chang Hee; Choi, Young Chan; Choi, Ji Suk; Cho, Yong Woo

    2017-01-01

    Self-assembled nanoparticles based on PEGylated human α-elastin were prepared as a potential vehicle for sustained protein delivery. The α-elastin was extracted from human adipose tissue and modified with methoxypolyethyleneglycol (mPEG) to control particle size and enhance the colloidal stability. The PEGylated human α-elastin showed sol-to-particle transition with a lower critical solution temperature (LCST) of 25°C-40°C in aqueous media. The PEGylated human α-elastin nanoparticles (PhENPs) showed a narrow size distribution with an average diameter of 330±33nm and were able to encapsulate significant amounts of insulin and bovine serum albumin (BSA) upon simple mixing at low temperature in water and subsequent heating to physiological temperature. The release profiles of insulin and BSA showed sustained release for 72h. Overall, the thermo-responsive self-assembled PhENPs provide a useful tool for a range of protein delivery and tissue engineering applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Spray-freeze-drying of nanosuspensions: the manufacture of insulin particles for needle-free ballistic powder delivery

    PubMed Central

    Schiffter, Heiko; Condliffe, Jamie; Vonhoff, Sebastian

    2010-01-01

    The feasibility of preparing microparticles with high insulin loading suitable for needle-free ballistic drug delivery by spray-freeze-drying (SFD) was examined in this study. The aim was to manufacture dense, robust particles with a diameter of around 50 µm, a narrow size distribution and a high content of insulin. Atomization using ultrasound atomizers showed improved handling of small liquid quantities as well as narrower droplet size distributions over conventional two-fluid nozzle atomization. Insulin nanoparticles were produced by SFD from solutions with a low solid content (<10 mg ml−1) and subsequent ultra-turrax homogenization. To prepare particles for needle-free ballistic injection, the insulin nanoparticles were suspended in matrix formulations with a high excipient content (>300 mg ml−1) consisting of trehalose, mannitol, dextran (10 kDa) and dextran (150 kDa) (abbreviated to TMDD) in order to maximize particle robustness and density after SFD. With the increase in insulin content, the viscosity of the nanosuspensions increased. Liquid atomization was possible up to a maximum of 250 mg of nano-insulin suspended in a 1.0 g matrix. However, if a narrow size distribution with a good correlation between theoretical and measurable insulin content was desired, no more than 150 mg nano-insulin could be suspended per gram of matrix formulation. Particles were examined by laser light diffraction, scanning electron microscopy and tap density testing. Insulin stability was assessed using size exclusion chromatography (SEC), reverse phase chromatography and Fourier transform infrared (FTIR) spectroscopy. Densification of the particles could be achieved during primary drying if the product temperature (Tprod) exceeded the glass transition temperature of the freeze concentrate (Tg′) of −29.4°C for TMDD (3∶3∶3∶1) formulations. Particles showed a collapsed and wrinkled morphology owing to viscous flow of the freeze concentrate. With increasing insulin loading, the d (v, 0.5) of the SFD powders increased and particle size distributions got wider. Insulin showed a good stability during the particle formation process with a maximum decrease in insulin monomer of only 0.123 per cent after SFD. In accordance with the SEC data, FTIR analysis showed only a small increase in the intermolecular β-sheet of 0.4 per cent after SFD. The good physical stability of the polydisperse particles made them suitable for ballistic injection into tissue-mimicking agar hydrogels, showing a mean penetration depth of 251.3 ± 114.7 µm. PMID:20519207

  8. Markers of insulin resistance and sedentary lifestyle are predictors of preeclampsia in women with adverse obstetric results.

    PubMed

    Hoirisch-Clapauch, S; Benchimol-Barbosa, P R

    2011-12-01

    Some thrombophilias and severe preeclampsia may increase the risk for preterm deliveries and fetal death due to placental insufficiency. Our objective was to evaluate clinical and laboratory data as predictors of preeclampsia in a population of mothers with 3rd trimester fetal losses or preterm deliveries. In a longitudinal retrospective study, 54 consecutive women (age range: 16 to 39 years) with normotensive pregnancies were compared to 79 consecutive women with preeclampsia (age range: 16 to 43 years). Weight accrual rate (WAR) was arbitrarily defined as weight gain from age 18 years to the beginning of pregnancy divided by elapsed years. Independent predictors of preeclampsia were past history of oligomenorrhea, WAR >0.8 kg/years, pre-pregnancy or 1st trimester triglyceridemia >150 mg/dL, and elevated acanthosis nigricans in the neck. In a multivariate logistic regression model, two or more predictors conferred an odds ratio of 15 (95%CI [5.9-37]; P < 0.001) to develop preeclampsia (85% specificity, 73% sensitivity, c-statistic of 81 ± 4%; P < 0.0001). Clinical markers related to insulin resistance and sedentary lifestyles are strong independent predictors of preeclampsia in mothers with 3rd trimester fetal losses or preterm deliveries due to placental insufficiency. Women at risk for preeclampsia in this particular population might benefit from measures focused on overcoming insulin resistance.

  9. Comparison of vials and prefilled pens of a rapid-acting insulin analog on pharmacy budgets in a long-term care setting.

    PubMed

    Eby, Elizabeth L; Smolen, Lee J; Pitts, Amber C; Krueger, Linda A; Andrews, Jeffrey Scott

    2014-12-01

    Estimate budgetary impact for skilled nursing facility converting from individual patient supply (IPS) delivery of rapid-acting insulin analog (RAIA) 10-mL vials or 3-mL prefilled pens to 3-mL vials. A budget-impact model used insulin volume purchased and assumptions of length of stay (LOS), daily RAIA dose, and delivery protocol to estimate the cost impact of using 3-mL vials. Skilled nursing facility. Medicare Part A patients. Simulations conducted using 12-month current and future scenarios. Comparisons of RAIA use for 13- and 28-day LOS. RAIA costs and savings, waste reduction. For patients with 13-day LOS using 20 units/day of IPS insulin, the model estimated a 70% reduction in RAIA costs and units purchased and a 95% waste reduction for the 3-mL vial compared with the 10-mL vial. The estimated costs for prefilled pen use were 58% lower than for use of 10-mL vials. The incremental savings associated with 3-mL vial use instead of prefilled pens was 28%, attributable to differences in per-unit cost of insulin in vials versus prefilled pens. Using a more conservative scenario of 28-day LOS at 20 units/day, the model estimated a 40% reduction in RAIA costs and units purchased, resulting in a 91% reduction in RAIA waste for the 3-mL vial, compared with 10-mL vial. Budget-impact analysis of conversion from RAIA 10-mL vials or 3-mL prefilled pens to 3-mL vials estimated reductions in both insulin costs and waste across multiple scenarios of varying LOS and patient daily doses for skilled nursing facility stays.

  10. Long-term inflammatory response to liquid injectable silicone, cartilage, and silicone sheet.

    PubMed

    Hizal, Evren; Buyuklu, Fuat; Ozdemir, B Handan; Erbek, Selim S

    2014-11-01

    To show and compare the long-term inflammatory responses to subdermal microdroplet injections of 1,000 centistoke (cS) and 5,000 cS liquid injectable silicone (LIS), and to assess the applicability of insulin pen as an alternative LIS delivery device in an animal model. Animal study. Eighteen healthy adult Sprague-Dawley rats were used. Two graft recipient sites and four injection sites were prepared on each rat's back for: 1) autogenous auricular cartilage graft; 2) silicone sheet; 3) 1,000 cS LIS injection with insulin syringe; 4) 1,000 cS LIS injection with insulin pen; 5) 5,000 cS LIS injection with insulin syringe; and 6) 5,000 cS LIS injection with insulin pen. The animals were followed up for 6 months, and skin biopsies were examined for the evaluation of LIS microdroplets in situ and the degree of inflammatory tissue response. Immunohistochemistry was used for the examination of macrophages and the density of microvessels. Biopsies from 17 animals were assessed. There was no statistically significant difference among the groups in terms of the number of lymphocytes (P = 0.081), macrophages (P = 0.857), and neutrophils (P = 0.995), the degree of vascular proliferation (P = 0.698), and the mean LIS microdroplet diameter (P = 0.540). Grossly, there was no sign of granuloma formation in any of the specimens. There is a low-grade, well-tolerated long-term inflammatory response to microdroplet injections of 1,000 cS and 5,000 cS LIS that is comparable to autogenous cartilage graft in rats. Standard dose delivery devices such as insulin pens can be used for controlled LIS injections. N/A. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  11. The diet-derived short chain fatty acid propionate improves beta-cell function in humans and stimulates insulin secretion from human islets in vitro.

    PubMed

    Pingitore, Attilio; Chambers, Edward S; Hill, Thomas; Maldonado, Inmaculada Ruz; Liu, Bo; Bewick, Gavin; Morrison, Douglas J; Preston, Tom; Wallis, Gareth A; Tedford, Catriona; Castañera González, Ramón; Huang, Guo C; Choudhary, Pratik; Frost, Gary; Persaud, Shanta J

    2017-02-01

    Diet-derived short chain fatty acids (SCFAs) improve glucose homeostasis in vivo, but the role of individual SCFAs and their mechanisms of action have not been defined. This study evaluated the effects of increasing colonic delivery of the SCFA propionate on β-cell function in humans and the direct effects of propionate on isolated human islets in vitro. For 24 weeks human subjects ingested an inulin-propionate ester that delivers propionate to the colon. Acute insulin, GLP-1 and non-esterified fatty acid (NEFA) levels were quantified pre- and post-supplementation in response to a mixed meal test. Expression of the SCFA receptor FFAR2 in human islets was determined by western blotting and immunohistochemistry. Dynamic insulin secretion from perifused human islets was quantified by radioimmunoassay and islet apoptosis was determined by quantification of caspase 3/7 activities. Colonic propionate delivery in vivo was associated with improved β-cell function with increased insulin secretion that was independent of changes in GLP-1 levels. Human islet β-cells expressed FFAR2 and propionate potentiated dynamic glucose-stimulated insulin secretion in vitro, an effect that was dependent on signalling via protein kinase C. Propionate also protected human islets from apoptosis induced by the NEFA sodium palmitate and inflammatory cytokines. Our results indicate that propionate has beneficial effects on β-cell function in vivo, and in vitro analyses demonstrated that it has direct effects to potentiate glucose-stimulated insulin release and maintain β-cell mass through inhibition of apoptosis. These observations support ingestion of propiogenic dietary fibres to maintain healthy glucose homeostasis. © 2016 John Wiley & Sons Ltd.

  12. Solid lipid nanoparticles carrying chemotherapeutic drug across the blood-brain barrier through insulin receptor-mediated pathway.

    PubMed

    Kuo, Yung-Chih; Shih-Huang, Chun-Yuan

    2013-09-01

    Carmustine (BCNU)-loaded solid lipid nanoparticles (SLNs) were grafted with 83-14 monoclonal antibody (MAb) (83-14 MAb/BCNU-SLNs) and applied to the brain-targeting delivery. Human brain-microvascular endothelial cells (HBMECs) incubated with 83-14 MAb/BCNU-SLNs were stained to demonstrate the interaction between the nanocarriers and expressed insulin receptors (IRs). The results revealed that the particle size of 83-14 MAb/BCNU-SLNs decreased with an increasing weight percentage of Dynasan 114 (DYN). Storage at 4 °C for 6 weeks slightly deformed the colloidal morphology. In addition, poloxamer 407 on 83-14 MAb/BCNU-SLNs induced cytotoxicity to RAW264.7 cells and inhibited phagocytosis by RAW264.7 cells. An increase in the weight percentage of DYN from 0% to 67% slightly reduced the viability of RAW264.7 cells and promoted phagocytosis. Moreover, the transport ability of 83-14 MAb/BCNU-SLNs across the blood-brain barrier (BBB) in vitro enhanced with an increasing weight percentage of Tween 80. 83-14 MAb on MAb/BCNU-SLNs stimulated endocytosis by HBMECs via IRs and enhanced the permeability of BCNU across the BBB. 83-14 MAb/BCNU-SLNs can be a promising antitumor drug delivery system for transporting BCNU to the brain.

  13. Insulin stimulates syntaxin4 SNARE complex assembly via a novel regulatory mechanism.

    PubMed

    Kioumourtzoglou, Dimitrios; Gould, Gwyn W; Bryant, Nia J

    2014-04-01

    Insulin stimulates glucose transport into fat and muscle cells by increasing the exocytic trafficking rate of the GLUT4 facilitative glucose transporter from intracellular stores to the plasma membrane. Delivery of GLUT4 to the plasma membrane is mediated by formation of functional SNARE complexes containing syntaxin4, SNAP23, and VAMP2. Here we have used an in situ proximity ligation assay to integrate these two observations by demonstrating for the first time that insulin stimulation causes an increase in syntaxin4-containing SNARE complex formation in adipocytes. Furthermore, we demonstrate that insulin brings about this increase in SNARE complex formation by mobilizing a pool of syntaxin4 held in an inactive state under basal conditions. Finally, we have identified phosphorylation of the regulatory protein Munc18c, a direct target of the insulin receptor, as a molecular switch to coordinate this process. Hence, this report provides molecular detail of how the cell alters membrane traffic in response to an external stimulus, in this case, insulin.

  14. Enhanced paracellular transport of insulin can be achieved via transient induction of myosin light chain phosphorylation.

    PubMed

    Taverner, Alistair; Dondi, Ruggero; Almansour, Khaled; Laurent, Floriane; Owens, Siân-Eleri; Eggleston, Ian M; Fotaki, Nikoletta; Mrsny, Randall J

    2015-07-28

    The intestinal epithelium functions to effectively restrict the causal uptake of luminal contents but has been demonstrated to transiently increase paracellular permeability properties to provide an additional entry route for dietary macromolecules. We have examined a method to emulate this endogenous mechanism as a means of enhancing the oral uptake of insulin. Two sets of stable Permeant Inhibitor of Phosphatase (PIP) peptides were rationally designed to stimulate phosphorylation of intracellular epithelial myosin light chain (MLC) and screened using Caco-2 monolayers in vitro. Apical application of PIP peptide 640, designed to disrupt protein-protein interactions between protein phosphatase 1 (PP1) and its regulator CPI-17, resulted in a reversible and non-toxic transient reduction in Caco-2 monolayer trans-epithelial electric resistance (TEER) and opening of the paracellular route to 4kDa fluorescent dextran but not 70kDa dextran in vitro. Apical application of PIP peptide 250, designed to impede MYPT1-mediated regulation of PP1, also decreased TEER in a reversible and non-toxic manner but transiently opened the paracellular route to both 4 and 70kDa fluorescent dextrans. Direct injection of PIP peptides 640 or 250 with human insulin into the lumen of rat jejunum caused a decrease in blood glucose levels that was PIP peptide and insulin dose-dependent and correlated with increased pMLC levels. Systemic levels of insulin suggested approximately 3-4% of the dose injected into the intestinal lumen was absorbed, relative to a subcutaneous injection. Measurement of insulin levels in the portal vein showed a time window of absorption that was consistent with systemic concentration-time profiles and approximately 50% first-pass clearance by the liver. Monitoring the uptake of a fluorescent form of insulin suggested its uptake occurred via the paracellular route. Together, these studies add validation to the presence of an endogenous mechanism used by the intestinal epithelium to dynamically regulate its paracellular permeability properties and better define the potential to enhance the oral delivery of biopharmaceuticals via a transient regulation of an endogenous mechanism controlling the intestinal paracellular barrier. Copyright © 2015. Published by Elsevier B.V.

  15. The expanding role of aerosols in systemic drug delivery, gene therapy, and vaccination.

    PubMed

    Laube, Beth L

    2005-09-01

    Aerosolized medications have been used for centuries to treat respiratory diseases. Until recently, inhalation therapy focused primarily on the treatment of asthma and chronic obstructive pulmonary disease, and the pressurized metered-dose inhaler was the delivery device of choice. However, the role of aerosol therapy is clearly expanding beyond that initial focus. This expansion has been driven by the Montreal protocol and the need to eliminate chlorofluorocarbons (CFCs) from traditional metered-dose inhalers, by the need for delivery devices and formulations that can efficiently and reproducibly target the systemic circulation for the delivery of proteins and peptides, and by developments in medicine that have made it possible to consider curing lung diseases with aerosolized gene therapy and preventing epidemics of influenza and measles with aerosolized vaccines. Each of these drivers has contributed to a decade or more of unprecedented research and innovation that has altered how we think about aerosol delivery and has expanded the role of aerosol therapy into the fields of systemic drug delivery, gene therapy, and vaccination. During this decade of innovation, we have witnessed the coming of age of dry powder inhalers, the development of new soft mist inhalers, and improved pressurized metered-dose inhaler delivery as a result of the replacement of CFC propellants with hydrofluoroalkane. The continued expansion of the role of aerosol therapy will probably depend on demonstration of the safety of this route of administration for drugs that have their targets outside the lung and are administered long term (eg, insulin aerosol), on the development of new drugs and drug carriers that can efficiently target hard-to-reach cell populations within the lungs of patients with disease (eg, patients with cystic fibrosis or lung cancer), and on the development of devices that improve aerosol delivery to infants, so that early intervention in disease processes with aerosol therapy has a high probability of success.

  16. Self-assembled nanogel of hydrophobized dendritic dextrin for protein delivery.

    PubMed

    Ozawa, Yayoi; Sawada, Shin-Ichi; Morimoto, Nobuyuki; Akiyoshi, Kazunari

    2009-07-07

    Highly branched cyclic dextrin derivatives (CH-CDex) that are partly substituted with cholesterol groups have been synthesized. The CH-CDex forms monodisperse and stable nanogels with a hydrodynamic radii of approximately 10 nm by the self-assembly of 4-6 CH-CDex macromolecules in water. The CH-CDex nanogels spontaneously trap 10-16 molecules of fluorescein isothiocyanate-labeled insulin (FITC-Ins). The complex shows high colloidal stability: no dissociation of trapped insulin is observed after at least 1 month in phosphate buffer (0.1 M, pH 8.0). In the presence of bovine serum albumin (BSA, 50 mg . mL(-1)), which is a model blood system, the FITC-Ins trapped in the nanogels is continuously released ( approximately 20% at 12 h) without burst release. The high-density nanogel structure derived from the highly branched CDex significantly affects the stability of the nanogel-protein complex.

  17. Targeting Extracellular DNA to Deliver IGF-1 to the Injured Heart

    NASA Astrophysics Data System (ADS)

    Khan, Raffay S.; Martinez, Mario D.; Sy, Jay C.; Pendergrass, Karl D.; Che, Pao-Lin; Brown, Milton E.; Cabigas, E. Bernadette; Dasari, Madhuri; Murthy, Niren; Davis, Michael E.

    2014-03-01

    There is a great need for the development of therapeutic strategies that can target biomolecules to damaged myocardium. Necrosis of myocardium during a myocardial infarction (MI) is characterized by extracellular release of DNA, which can serve as a potential target for ischemic tissue. Hoechst, a histological stain that binds to double-stranded DNA can be conjugated to a variety of molecules. Insulin-like growth factor-1 (IGF-1), a small protein/polypeptide with a short circulating-half life is cardioprotective following MI but its clinical use is limited by poor delivery, as intra-myocardial injections have poor retention and chronic systemic presence has adverse side effects. Here, we present a novel delivery vehicle for IGF-1, via its conjugation to Hoechst for targeting infarcted tissue. Using a mouse model of ischemia-reperfusion, we demonstrate that intravenous delivery of Hoechst-IGF-1 results in activation of Akt, a downstream target of IGF-1 and protects from cardiac fibrosis and dysfunction following MI.

  18. Photomechanical drug delivery

    NASA Astrophysics Data System (ADS)

    Doukas, Apostolos G.; Lee, Shun

    2000-05-01

    Photomechanical waves (PW) are generated by Q-switched or mode-locked lasers. Ablation is a reliable method for generating PWs with consistent characteristics. Depending on the laser wavelength and target material, PWs with different parameters can be generated which allows the investigation of PWs with cells and tissue. PWs have been shown to permeabilize the stratum corneum (SC) in vivo and facilitate the transport of drugs into the skin. Once a drug has diffused into the dermis it can enter the vasculature, thus producing a systemic effect. Fluorescence microscopy of biopsies show that 40-kDa molecules can be delivered to a depth of > 300 micrometers into the viable skin of rats. Many important drugs such as insulin, and erythropoietin are smaller or comparable in size, making the PWs attractive for transdermal drug delivery. There are three possible pathways through the SC: Transappendageal via hair follicles or other appendages, transcellular through the corneocytes, and intercellular via the extracellular matrix. The intracellular route appears to be the most likely pathway of drug delivery through the SC.

  19. Ben Taub General Hospital & LifeGift: Strengthening a Partnership to Save Lives and Improve Healthcare Delivery

    DTIC Science & Technology

    2007-05-24

    0.9% sodium chloride will be prepared, dispensed, and administered intravenously to the organ donor. Subsequent to the initiation of the potassium...of methylprednisolone, 20 units of regular insulin, and 20 micrograms of levothyroxine . The dextrose and insulin are contained within vials that can...be obtained from the Pyxis pharmaceutical dispensing machine. Methylprednisolone and levothyroxine are contained in vials in the main pharmacy. Once

  20. Falling insulin requirements are associated with adverse obstetric outcomes in women with preexisting diabetes.

    PubMed

    Padmanabhan, Suja; McLean, Mark; Cheung, N Wah

    2014-10-01

    To investigate the clinical significance of falling insulin requirements in women with preexisting or overt diabetes in pregnancy. A retrospective review of 139 pregnancies was conducted in women, with preexisting diabetes, delivering between January 2010 and January 2013. Women with falling insulin requirements of 15% or more from the peak total daily dose in late pregnancy were considered case subjects (n = 35). The primary outcome consisted of a composite of clinical markers of placental dysfunction, including preeclampsia, small for gestational age (SGA, ≤5th percentile for gestational age), stillbirth (>20 weeks), and premature delivery (≤30 weeks). A total of 25.2% of women had >15% fall in insulin requirements with nulliparity as the only predictor at baseline (odds ratio [OR] 2.5 [95% CI 1.1-5.7], P = 0.03). Falling insulin requirements were associated with an increased risk of preeclampsia (OR 3.5 [1.1-10.7], P < 0.05) and the composite of clinical markers of placental dysfunction (4.4 [1.73-11.26], P = 0.002). Although falling insulin requirements were associated with higher rates of SGA (3.4 [1.0-11.3], P = 0.048), they were not associated with other adverse neonatal outcomes. However, there was a higher incidence of neonatal intensive care unit admission (15.5 [3.1-77.6], P = 0.001) and earlier delivery in this group (median 37.7 weeks [IQR 34.3-38.4] vs. 38.3 weeks [37.4-38.9], P = 0.014). Falling insulin requirements, in women with preexisting diabetes, are associated with an increased risk of complications related to placental dysfunction. Further prospective studies are needed to guide clinical management. © 2014 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  1. Effects of intranasal insulin on hepatic fat accumulation and energy metabolism in humans.

    PubMed

    Gancheva, Sofiya; Koliaki, Chrysi; Bierwagen, Alessandra; Nowotny, Peter; Heni, Martin; Fritsche, Andreas; Häring, Hans-Ulrich; Szendroedi, Julia; Roden, Michael

    2015-06-01

    Studies in rodents suggest that insulin controls hepatic glucose metabolism through brain-liver crosstalk, but human studies using intranasal insulin to mimic central insulin delivery have provided conflicting results. In this randomized controlled crossover trial, we investigated the effects of intranasal insulin on hepatic insulin sensitivity (HIS) and energy metabolism in 10 patients with type 2 diabetes and 10 lean healthy participants (CON). Endogenous glucose production was monitored with [6,6-(2)H2]glucose, hepatocellular lipids (HCLs), ATP, and inorganic phosphate concentrations with (1)H/(31)P magnetic resonance spectroscopy. Intranasal insulin transiently increased serum insulin levels followed by a gradual lowering of blood glucose in CON only. Fasting HIS index was not affected by intranasal insulin in CON and patients. HCLs decreased by 35% in CON only, whereas absolute hepatic ATP concentration increased by 18% after 3 h. A subgroup of CON received intravenous insulin to mimic the changes in serum insulin and blood glucose levels observed after intranasal insulin. This resulted in a 34% increase in HCLs without altering hepatic ATP concentrations. In conclusion, intranasal insulin does not affect HIS but rapidly improves hepatic energy metabolism in healthy humans, which is independent of peripheral insulinemia. These effects are blunted in patients with type 2 diabetes. © 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  2. Exponential increase in postprandial blood-glucose exposure with increasing carbohydrate loads using a linear carbohydrate-to-insulin ratio.

    PubMed

    Marran, K J; Davey, B; Lang, A; Segal, D G

    2013-04-10

    Postprandial glucose excursions contribute significantly to average blood glucose, glycaemic variability and cardiovascular risk. Carbohydrate counting is a method of insulin dosing that balances carbohydrate load to insulin dose using a fixed ratio. Many patients and current insulin pumps calculate insulin delivery for meals based on a linear carbohydrate-to-insulin relationship. It is our hypothesis that a non-linear relationship exists between the amounts of carbohydrate consumed and the insulin required to cover it. To document blood glucose exposure in response to increasing carbohydrate loads on fixed carbohydrate-to-insulin ratios. Five type 1 diabetic subjects receiving insulin pump therapy with good control were recruited. Morning basal rates and carbohydrate- to-insulin ratios were optimised. A Medtronic glucose sensor was used for 5 days to collect data for area-under-the-curve (AUC) analysis, during which standardised meals of increasing carbohydrate loads were consumed. Increasing carbohydrate loads using a fixed carbohydrate-to-insulin ratio resulted in increasing glucose AUC. The relationship was found to be exponential rather than linear. Late postprandial hypoglycaemia followed carbohydrate loads of >60 g and this was often followed by rebound hyperglycaemia that lasted >6 hours. A non-linear relationship exists between carbohydrates consumed and the insulin required to cover them. This has implications for control of postprandial blood sugars, especially when consuming large carbohydrate loads. Further studies are required to look at the optimal ratios, duration and type of insulin boluses required to cover increasing carbohydrate loads.

  3. Improved glycaemic control and treatment satisfaction with a simple wearable 3-day insulin delivery device among people with Type 2 diabetes.

    PubMed

    Mader, J K; Lilly, L C L; Aberer, F; Poettler, T; Johns, D; Trautmann, M; Warner, J; Pieber, T R

    2018-06-11

    To evaluate the PAQ ® (CeQur SA, Horw, Switzerland), a wearable 3-day insulin delivery device that provides set basal rates and bolus insulin on demand, in people with Type 2 diabetes. Adults with Type 2 diabetes with HbA 1c concentrations ≥53 and ≤97 mmol/mol (7.0 and 11.0%) while treated with ≥2 insulin injections/day were enrolled in two single-arm studies comprising three periods: a baseline (insulin injections), a transition and a PAQ treatment period (12 weeks). Endpoints included HbA 1c , seven-point self-monitored blood glucose, total daily dose of insulin and body weight. Safety was assessed according to examination, hypoglycaemic episodes and adverse device effects. A total of 28 adults were enrolled (age 63 ± 7 years, 86% men, BMI 32.3 ± 4.3kg/m 2 , Type 2 diabetes duration 17 ± 8 years, HbA 1c 70 ± 12 mmol/mol (8.6 ± 1.1%), total daily insulin dose 58.7 ± 20.7 U), of whom 24 completed the studies. When transitioned to PAQ, 75% of participants continued on the first basal rate selected. After 12 weeks of PAQ wear, significant improvements from baseline were seen [HbA 1c -16 ± 9 mmol/mol (95% CI -20, -12) or -1.5 ± 0.9% (95% CI -1.8, -1.1) P<0.0001], and at all seven self-monitored blood glucose readings time points (P ≤0.03). Total daily insulin dose increased by 12.1 ± 19.5 U (95% CI 3.9, 20.4; P=0.0058), the number of meal time boluses increased by 0.9 ± 1.5/day (95% CI 0.3, 1.5; P=0.0081) and body weight remained stable. Six participants had mild to moderate catheter site reactions and one mild skin irritation occurred. No participant experienced severe hypoglycaemia. Adults with Type 2 diabetes were safely transitioned from insulin injections to the PAQ and had significantly improved glycaemic control and treatment satisfaction with insulin therapy. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. The ASPIRE study: design and methods of an in-clinic crossover trial on the efficacy of automatic insulin pump suspension in exercise-induced hypoglycemia.

    PubMed

    Brazg, Ronald L; Bailey, Timothy S; Garg, Satish; Buckingham, Bruce A; Slover, Robert H; Klonoff, David C; Nguyen, Xuan; Shin, John; Welsh, John B; Lee, Scott W

    2011-11-01

    The Paradigm®Veo™ System includes a low glucose suspend (LGS) feature which suspends insulin delivery when a prespecified glucose threshold setting is reached by the associated continuous glucose monitoring (CGM) sensor. The ASPIRE (Automation to Simulate Pancreatic Insulin REsponse) study is a multicenter, in-clinic, randomized, crossover study to examine the efficacy of LGS in exercise-induced hypoglycemia. Insulin-pump users underwent two separate exercise sessions, one with the LGS feature set to suspend insulin (LGS-on) when the CGM-detected glucose concentration was ≤ 70 mg/dl and one with the LGS feature off. Exercise sessions were conducted after an overnight fast and with initial plasma glucose level as measured by the YSI 2300 STAT Plus glucose analyzer (YSI) of 100-140 mg/dl. Subjects exercised until their YSI value fell to ≤ 85 mg/dl; subsequent YSI values <70 mg/dl were recorded for up to 4 h to measure the duration and nadir of hypoglycemia. The protocol required that subjects with YSI values <50 or >300 mg/dl were rescued with carbohydrates or insulin, respectively, based on the provider's recommendation. The primary end point was comparison of duration and severity of hypoglycemia between LGS-on and LGS-off sessions. Secondary end points included areas under the glucose concentration curve, CGM sensor accuracy, and last YSI glucose. Device- and procedure-related adverse events and serious adverse events were recorded. Fifty adults and teenagers (17-58 years) with type 1 diabetes were randomized. Study completion is expected in November 2011. © 2011 Diabetes Technology Society.

  5. Insulin Particle Formation in Supersaturated Aqueous Solutions of Poly(Ethylene Glycol)

    PubMed Central

    Bromberg, Lev; Rashba-Step, Julia; Scott, Terrence

    2005-01-01

    Protein microspheres are of particular utility in the field of drug delivery. A novel, completely aqueous, process of microsphere fabrication has been devised based on controlled phase separation of protein from water-soluble polymers such as polyethylene glycols. The fabrication process results in the formation of spherical microparticles with narrow particle size distributions. Cooling of preheated human insulin-poly(ethylene glycol)-water solutions results in the facile formation of insulin particles. To map out the supersaturation conditions conducive to particle nucleation and growth, we determined the temperature- and concentration-dependent boundaries of an equilibrium liquid-solid phase separation. The kinetics of formation of microspheres were followed by dynamic and continuous-angle static light scattering techniques. The presence of PEG at a pH that was close to the protein's isoelectric point resulted in rapid nucleation and growth. The time elapsed from the moment of creation of a supersaturated solution and the detection of a solid phase in the system (the induction period, tind) ranged from tens to several hundreds of seconds. The dependence of tind on supersaturation could be described within the framework of classical nucleation theory, with the time needed for the formation of a critical nucleus (size <10 nm) being much longer than the time of the onset of particle growth. The growth was limited by cluster diffusion kinetics. The interfacial energies of the insulin particles were determined to be 3.2–3.4 and 2.2 mJ/m2 at equilibrium temperatures of 25 and 37°C, respectively. The insulin particles formed as a result of the process were monodisperse and uniformly spherical, in clear distinction to previously reported processes of microcrystalline insulin particle formation. PMID:16254391

  6. ADVANCED MOLECULAR DESIGN OF BIOPOLYMERS FOR TRANSMUCOSAL AND INTRACELLULAR DELIVERY OF CHEMOTHERAPEUTIC AGENTS AND BIOLOGICAL THERAPEUTICS

    PubMed Central

    Liechty, William B.; Caldorera-Moore, Mary; Phillips, Margaret A.; Schoener, Cody; Peppas, Nicholas A.

    2011-01-01

    Hydrogels have been instrumental in the development of polymeric systems for controlled release of therapeutic agents. These materials are attractive for transmucosal and intracellular drug delivery because of their facile synthesis, inherent biocompatibility, tunable physicochemical properties, and capacity to respond to various physiological stimuli. In this contribution, we outline a multifaceted hydrogel-based approach for expanding the range of therapeutics in oral formulations from classical small-molecule drugs to include proteins, chemotherapeutics, and nucleic acids. Through judicious materials selection and careful design of copolymer composition and molecular architecture, we can engineer systems capable of responding to distinct physiological cues, with tunable physicochemical properties that are optimized to load, protect, and deliver valuable macromolecular payloads to their intended site of action. These hydrogel carriers, including complexation hydrogels, tethered hydrogels, interpenetrating networks, nanoscale hydrogels, and hydrogels with decorated structures are investigated for their ability respond to changes in pH, to load and release insulin and fluorescein, and remain non-toxic to Caco-2 cells. Our results suggest these novel hydrogel networks have great potential for controlled delivery of proteins, chemotherapeutics, and nucleic acids. PMID:21699934

  7. Thiomers for oral delivery of hydrophilic macromolecular drugs.

    PubMed

    Bernkop-Schnürch, Andreas; Hoffer, Martin H; Kafedjiiski, Krum

    2004-11-01

    In recent years thiolated polymers (thiomers) have appeared as a promising new tool in oral drug delivery. Thiomers are obtained by the immobilisation of thio-bearing ligands to mucoadhesive polymeric excipients. By the formation of disulfide bonds with mucus glycoproteins, the mucoadhesive properties of thiomers are up to 130-fold improved compared with the corresponding unmodified polymers. Owing to the formation of inter- and intramolecular disulfide bonds within the thiomer itself, matrix tablets and particulate delivery systems show strong cohesive properties, resulting in comparatively higher stability, prolonged disintegration times and a more controlled drug release. The permeation of hydrophilic macromolecular drugs through the gastrointestinal (GI) mucosa can be improved by the use of thiomers. Furthermore, some thiomers exhibit improved inhibitory properties towards GI peptidases. The efficacy of thiomers in oral drug delivery has been demonstrated by various in vivo studies. A pharmacological efficacy of 1%, for example, was achieved in rats by oral administration of calcitonin tablets comprising a thiomer. Furthermore, tablets comprising a thiomer and pegylated insulin resulted in a pharmacological efficacy of 7% after oral application to diabetic mice. Low-molecular-weight heparin embedded in thiolated polycarbophil led to an absolute bioavailability of > or = 20% after oral administration to rats. In these studies, formulations comprising the corresponding unmodified polymer had only a marginal or no effect. These results indicate drug carrier systems based on thiomers appear to be a promising tool for oral delivery of hydrophilic macromolecular drugs.

  8. Young people with type 1 diabetes mellitus: Attitudes, perceptions, and experiences of diabetes management and continuous subcutaneous insulin infusion therapy.

    PubMed

    Perry, Lin; James, Steven; Steinbeck, Katharine; Dunbabin, Janet; Lowe, Julia

    2017-06-01

    Continuous subcutaneous insulin infusion (CSII; insulin pump) use is increasing. However, there is little information about how this technology is used compared with other insulin delivery methods (ie, injections) by young people with type 1 diabetes mellitus in Australia. This study explored young people's attitudes, perceptions, and experiences with diabetes management comparing those using with those not using CSII, and proportions likely to transition to adult services requiring initiation and/or support for CSII use. A survey was undertaken of young people (aged 12 to 18 years) with type 1 diabetes mellitus and their parents/guardians living in Hunter New England, Australia, using a questionnaire designed to collect quantitative, descriptive, and demographic data. Most questions were based on previously developed and validated instruments. In total, 107 respondents returned partially or fully completed questionnaires. Respondents had positive attitudes and perceptions of their self-efficacy and diabetes management, but were moderately disturbed by their diabetes and reported experiencing suboptimal management outcomes. Patterns of associations were demonstrated between knowledge, attitudes, and experiences of diabetes modeled by regression analysis. There were no statistically significant differences in responses between users and nonusers of CSII. Over 40% indicated their intention to use the technology as adults. Opportunities for enhanced diabetes service support were clear, and CSII did not appear to be used to its full potential. Service redesign could enhance support for this young population using all preferred insulin delivery methods and should align to patients' goals and preferences to maximize service and patient gain. © 2017 John Wiley & Sons, Ltd.

  9. Investigation of Chitosan for Prevention of Diabetic Progression Through Gut Microbiota Alteration in Sugar Rich Diet Induced Diabetic Rats.

    PubMed

    Prajapati, Bhumika; Rajput, Parth; Jena, Prasant Kumar; Seshadri, Sriram

    2015-01-01

    Sugar rich diet induces inflammation and insulin resistance mainly through gut microbiota alteration. Gut microflora dysbiosis increases plasma lipopolysaccharide and reduces short chain fatty acids to impair the insulin signaling cascades by different molecular pathways to progress into diabetes. Chitosan based formulations have major significance in insulin delivery system due to their ability to protect the insulin from enzymatic degradation and its efficient inter-epithelial transport. This study was designed to investigate the effect of chitosan administration on gut microflora mediated signaling pathways to prevent the diet induced diabetes. Male wistar rats were divided into non-diabetic group with a normal diet (CD), diabetic group with high sucrose diet (HSD) and treatment group with HSD and chitosan (60 mg/kg). After 8 weeks of the study, significant alterations in two major gut dominant microbial phyla i.e Firmicutes and Bacteroides and four dominant microbial species i.e. Lactobacilli, Bifidobacteria, Escherichia and Clostridia were observed in HSD group compared to CD. This microbial dysbiosis in dominant phyla was significantly prevented in chitosan administrated HSD group. Chitosan administration had also reduced the HSD induced activation of Toll like receptors and Nod like receptors signaling pathways compared to HSD control group to reduce the inflammation. These suggest that chitosan can prevent the progression of Type 2 Diabetes through gut microbiota alteration, reducing endotoxin and microbes mediated inflammation.

  10. Banting Memorial Lecture 2014* Technology and diabetes care: appropriate and personalized.

    PubMed

    Pickup, J C

    2015-01-01

    Continuous subcutaneous insulin infusion was initially developed as a research procedure in the 1970s but quickly became a routine treatment for selected people with Type 1 diabetes. Continuous subcutaneous insulin infusion and other diabetes technologies, such as continuous glucose monitoring, are now an established and evidence-based part of diabetes care, but there has been some confusion about effectiveness and best use, particularly because of conflicting results from meta-analyses. This is because literature summary meta-analyses (including all trials) are inappropriate for therapeutic and economic decision-making; such meta-analyses should only include trials representative of groups likely to benefit. For example, for continuous subcutaneous insulin infusion, this would be those with continued disabling hypoglycaemia or elevated HbA1c levels. Alternatively, individual patient data meta-analysis allows modelling of covariates that determine effect size, e.g. in the case of continuous glucose monitoring, baseline HbA1c and frequency of sensor usage. Diabetes technology is therefore an example of personalized medicine, where evaluation and use should be both appropriate and targeted. This will also apply to future technologies such as new 'patch' pumps for Type 2 diabetes, closed-loop insulin delivery systems and nanomedicine applications in diabetes that we are currently researching. These include fluorescence lifetime-based non-invasive glucose monitoring and nanoencapsulation of islets for improved post-transplant survival. © 2014 The Author. Diabetic Medicine © 2014 Diabetes UK.

  11. Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis.

    PubMed

    Yeh, Hsin-Chieh; Brown, Todd T; Maruthur, Nisa; Ranasinghe, Padmini; Berger, Zackary; Suh, Yong D; Wilson, Lisa M; Haberl, Elisabeth B; Brick, Jessica; Bass, Eric B; Golden, Sherita Hill

    2012-09-04

    Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring. To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions. 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4). 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data. In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes. Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus. Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia. Agency for Healthcare Research and Quality.

  12. Automated hybrid closed-loop control with a proportional-integral-derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance.

    PubMed

    Ly, Trang T; Weinzimer, Stuart A; Maahs, David M; Sherr, Jennifer L; Roy, Anirban; Grosman, Benyamin; Cantwell, Martin; Kurtz, Natalie; Carria, Lori; Messer, Laurel; von Eyben, Rie; Buckingham, Bruce A

    2017-08-01

    Automated insulin delivery systems, utilizing a control algorithm to dose insulin based upon subcutaneous continuous glucose sensor values and insulin pump therapy, will soon be available for commercial use. The objective of this study was to determine the preliminary safety and efficacy of initialization parameters with the Medtronic hybrid closed-loop controller by comparing percentage of time in range, 70-180 mg/dL (3.9-10 mmol/L), mean glucose values, as well as percentage of time above and below target range between sensor-augmented pump therapy and hybrid closed-loop, in adults and adolescents with type 1 diabetes. We studied an initial cohort of 9 adults followed by a second cohort of 15 adolescents, using the Medtronic hybrid closed-loop system with the proportional-integral-derivative with insulin feed-back (PID-IFB) algorithm. Hybrid closed-loop was tested in supervised hotel-based studies over 4-5 days. The overall mean percentage of time in range (70-180 mg/dL, 3.9-10 mmol/L) during hybrid closed-loop was 71.8% in the adult cohort and 69.8% in the adolescent cohort. The overall percentage of time spent under 70 mg/dL (3.9 mmol/L) was 2.0% in the adult cohort and 2.5% in the adolescent cohort. Mean glucose values were 152 mg/dL (8.4 mmol/L) in the adult cohort and 153 mg/dL (8.5 mmol/L) in the adolescent cohort. Closed-loop control using the Medtronic hybrid closed-loop system enables adaptive, real-time basal rate modulation. Initializing hybrid closed-loop in clinical practice will involve individualizing initiation parameters to optimize overall glucose control. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Emerging Roles for MicroRNAs in Diabetic Microvascular Disease: Novel Targets for Therapy

    PubMed Central

    Zhang, Yu; Sun, Xinghui; Icli, Basak

    2017-01-01

    Chronic, low-grade systemic inflammation and impaired microvascular function are critical hallmarks in the development of insulin resistance. Accordingly, insulin resistance is a major risk factor for type 2 diabetes and cardiovascular disease. Accumulating studies demonstrate that restoration of impaired function of the diabetic macro- and microvasculature may ameliorate a range of cardiovascular disease states and diabetes-associated complications. In this review, we focus on the emerging role of microRNAs (miRNAs), noncoding RNAs that fine-tune target gene expression and signaling pathways, in insulin-responsive tissues and cell types important for maintaining optimal vascular homeostasis and preventing the sequelae of diabetes-induced end organ injury. We highlight current pathophysiological paradigms of miRNAs and their targets involved in regulating the diabetic microvasculature in a range of diabetes-associated complications such as retinopathy, nephropathy, wound healing, and myocardial injury. We provide an update of the potential use of circulating miRNAs diagnostically in type I or type II diabetes. Finally, we discuss emerging delivery platforms for manipulating miRNA expression or function as the next frontier in therapeutic intervention to improve diabetes-associated microvascular dysfunction and its attendant clinical consequences. PMID:28323921

  14. Psychology, technology, and diabetes management.

    PubMed

    Gonder-Frederick, Linda A; Shepard, Jaclyn A; Grabman, Jesse H; Ritterband, Lee M

    2016-10-01

    Use of technology in diabetes management is rapidly advancing and has the potential to help individuals with diabetes achieve optimal glycemic control. Over the past 40 years, several devices have been developed and refined, including the blood glucose meter, insulin pump, and continuous glucose monitor. When used in tandem, the insulin pump and continuous glucose monitor have prompted the Artificial Pancreas initiative, aimed at developing control system for fully automating glucose monitoring and insulin delivery. In addition to devices, modern technology, such as the Internet and mobile phone applications, have been used to promote patient education, support, and intervention to address the behavioral and emotional challenges of diabetes management. These state-of-the-art technologies not only have the potential to improve clinical outcomes, but there are possible psychological benefits, such as improved quality of life, as well. However, practical and psychosocial limitations related to advanced technology exist and, in the context of several technology-related theoretical frameworks, can influence patient adoption and continued use. It is essential for future diabetes technology research to address these barriers given that the clinical benefits appear to largely depend on patient engagement and consistence of technology use. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. 21 CFR 862.1405 - Immunoreactive insulin test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Immunoreactive insulin test system. 862.1405... Systems § 862.1405 Immunoreactive insulin test system. (a) Identification. An immunoreactive insulin test system is a device intended to measure immunoreactive insulin in serum and plasma. Immunoreactive insulin...

  16. 21 CFR 862.1405 - Immunoreactive insulin test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Immunoreactive insulin test system. 862.1405... Systems § 862.1405 Immunoreactive insulin test system. (a) Identification. An immunoreactive insulin test system is a device intended to measure immunoreactive insulin in serum and plasma. Immunoreactive insulin...

  17. 21 CFR 862.1405 - Immunoreactive insulin test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunoreactive insulin test system. 862.1405... Systems § 862.1405 Immunoreactive insulin test system. (a) Identification. An immunoreactive insulin test system is a device intended to measure immunoreactive insulin in serum and plasma. Immunoreactive insulin...

  18. 21 CFR 862.1405 - Immunoreactive insulin test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Immunoreactive insulin test system. 862.1405... Systems § 862.1405 Immunoreactive insulin test system. (a) Identification. An immunoreactive insulin test system is a device intended to measure immunoreactive insulin in serum and plasma. Immunoreactive insulin...

  19. New Approaches to Providing Individualized Diabetes Care in the 21st Century

    PubMed Central

    Powell, Priscilla W.; Corathers, Sarah D.; Raymond, Jennifer; Streisand, Randi

    2016-01-01

    Building from a foundation of rapid innovation, the 21st century is poised to offer considerable new approaches to providing modern diabetes care. The focus of this paper is the evolving role of diabetes care providers collaboratively working with patients and families toward the goals of achieving optimal clinical and psychosocial outcomes for individuals living with diabetes. Advances in monitoring, treatment and technology have been complemented by trends toward patient-centered care with expertise from multiple health care disciplines. The evolving clinical care delivery system extends far beyond adjustment of insulin regimens. Effective integration of patient-centered strategies, such as shared-decision making, motivational interviewing techniques, shared medical appointments, and multidisciplinary team collaboration, into a dynamic model of diabetes care delivery holds promise in reaching glycemic targets and improving patients’ quality of life. PMID:25901504

  20. Lack of effect of sodium nitroprusside on insulin-mediated blood flow and glucose disposal in the elderly.

    PubMed

    Meneilly, G S; Battistini, B; Floras, J S

    2000-03-01

    Insulin increases skeletal muscle blood flow in healthy young subjects by a nitric oxide (NO)-dependent mechanism. Impairment of this mechanism may contribute to the insulin resistance of normal aging, a state characterized by reduced endothelial production of NO, an attenuated effect of insulin on skeletal muscle blood flow, and resistance to insulin-mediated glucose uptake (IMGU). We tested the hypothesis that the NO donor sodium nitroprusside (SNP) would augment insulin-mediated vasodilation and thus increase IMGU in healthy elderly subjects. Experiments were performed with young (n = 9; age, 25 +/- 1 years; body mass index [BMI], 24 +/- 1 kg/m2) and old (n = 10; age, 78 +/- 2 years; BMI, 25 +/- 1 kg/m2) healthy subjects. Each group underwent two studies in random order. In one study (control), insulin was infused using the euglycemic clamp protocol for 240 minutes at a rate of 40 mU/m2/min (young) and 34 mU/m2/min (old). In the other study (SNP), SNP was coinfused with insulin from 120 to 240 minutes. At regular intervals in each study, blood samples were obtained and calf blood flow was measured using venous occlusion plethysmography. Glucose and insulin values were similar in control and SNP studies in both age groups. In the young, SNP had no effect on blood flow to the calf, but its action in calf resistance vessels augmented insulin-mediated vasodilation, since incremental calf vascular conductance was greater during SNP infusion (control v SNP, 0.027 +/- 0.002 v 0.040 +/- 0.008 mL/100 mL/min/mm Hg, P< .0001). However, SNP had no effect on insulin-mediated glucose disposal. In the elderly, SNP reduced the blood flow to the calf, but this was countered by its effect on calf resistance vessels such that vascular conductance was unaffected (control v SNP, 0.012 +/- 0.003 v 0.011 +/- 0.003 mL/100 mL/min/mm Hg, P = nonsignificant [NS]). Steady-state (180 to 240 minutes) glucose disposal (control v SNP, 7.47 +/- 0.47 v 6.54 +/- 0.56 mg/kg/min, P < .01) rates were significantly lower during SNP infusion. In summary, systemic infusion of SNP did not increase insulin-mediated glucose disposal in either young or old subjects. Thus, the present findings do not support the concept that increasing NO availability will enhance glucose disposal in either age group. However, because the incremental increases in IMGU during SNP infusion paralleled the changes in blood supply to the calf rather than calf vascular conductance, any potential benefits on NO delivery in elderly subjects may have been offset by the direct or reflex effects of systemic hypotension. Other stimuli to NO production that do not cause hypotension must be tested before this therapeutic strategy can be considered as a potential means for enhancing the metabolic actions of insulin in the elderly.

  1. The role of adding metformin in insulin-resistant diabetic pregnant women: a randomized controlled trial.

    PubMed

    Ibrahim, Moustafa Ibrahim; Hamdy, Ahmed; Shafik, Adel; Taha, Salah; Anwar, Mohammed; Faris, Mohammed

    2014-05-01

    The aim of the present study is to assess the impact of adding oral metformin to insulin therapy in pregnant women with insulin-resistant diabetes mellitus. The current non-inferiority randomized controlled trial was conducted at Ain Shams University Maternity Hospital. The study included pregnant women with gestational or pre-existing diabetes mellitus at gestations between 20 and 34 weeks, who showed insulin resistance (defined as poor glycemic control at a daily dose of ≥1.12 units/kg). Recruited women were randomized into one of two groups: group I, including women who received oral metformin without increasing the insulin dose; and group II, including women who had their insulin dose increased. The primary outcome was maternal glycemic control. Secondary outcomes included maternal bouts of hypoglycemia, need for another hospital admission for uncontrolled diabetes during pregnancy, gestational age at delivery, mode of delivery, birth weight, birth trauma, congenital anomalies, 1- and 5-min Apgar score, neonatal hypoglycemia, need for neonatal intensive care unit (NICU) admission and adverse neonatal outcomes. A total number of 154 women with diabetes mellitus with pregnancy were approached; of them 90 women were eligible and were randomly allocated and included in the final analysis. The recruited 90 women were randomized into one of two groups: group I (metformin group) (n = 46), including women who received oral metformin in addition to the same initial insulin dose; and group II (control group) (n = 44), including women who had their insulin dose increased according to the standard protocol. The mean age of included women was 29.84 ± 5.37 years (range 20-42 years). The mean gestational age at recruitment was 28.7 ± 3.71 weeks (range 21-34 weeks). Among the 46 women of group I, 17 (36.9 %) women reached proper glycemic control at a daily metformin dose of 1,500 mg, 18 (39.2 %) at a daily dose of 2,000 mg, while 11 (23.9 %) received metformin at a daily dose of 2,000 mg without reaching proper glycemic control and needed raising the dose of insulin dose. Adding metformin to insulin therapy in women with insulin-resistant diabetes mellitus with pregnancy seems to be effective in proper glycemic control in a considerable proportion of women, along with benefits of reduced hospital stay, reduced frequency of maternal hypoglycemia as well as reduced frequency of neonatal hypoglycemia, NICU admission and neonatal respiratory distress syndrome.

  2. Associations of maternal weight status prior and during pregnancy with neonatal cardio-metabolic markers at birth: The Healthy Start Study

    PubMed Central

    Lemas, Dominick J.; Brinton, John T.; Shapiro, Allison L. B.; Glueck, Deborah H.; Friedman, Jacob E.; Dabelea, Dana

    2015-01-01

    Background Maternal obesity increases adult offspring risk for cardiovascular disease; however the role of offspring adiposity in mediating this association remains poorly characterized. Objective To investigate the associations of maternal pre-pregnant body mass index (maternal BMI) and gestational weight gain (GWG) with neonatal cardio-metabolic markers independent of fetal growth and neonatal adiposity. Methods A total of 753 maternal-infant pairs from the Healthy Start study, a large multi-ethnic pre-birth observational cohort were used. Neonatal cardio-metabolic markers included cord blood glucose, insulin, glucose-to-insulin ratio (Glu/Ins), total and high-density lipoprotein cholesterol (HDL-c), triglycerides, free fatty acids and leptin. Maternal BMI was abstracted from medical records or self-reported. GWG was calculated as the difference between the first pre-pregnant weight and the last weight measurement before delivery. Neonatal adiposity (percent fat mass) was measured within 72 hours of delivery using whole body air displacement plethysmography. Results In covariate adjusted models, maternal BMI was positively associated with cord blood insulin (p=0.01) and leptin (p<0.001) levels and inversely associated with cord blood HDL-c (p=0.05) and Glu/Ins (p=0.003). Adjustment for fetal growth or neonatal adiposity attenuated the effect of maternal BMI on neonatal insulin, rendering the association non-significant. However, maternal BMI remained associated with higher leptin (p<0.0011), lower HDL-c (p=0.02) and Glu/Ins (p=0.05), independent of neonatal adiposity. GWG was positively associated with neonatal insulin (p=0.02), glucose (p=0.03) and leptin levels (p<0.001) and negatively associated with Glu/Ins (p=0.006). After adjusting for neonatal adiposity, GWG remained associated with higher neonatal glucose (p=0.02) and leptin levels (p=0.02) and lower Glu/Ins (p=0.048). Conclusions Maternal weight prior and/or during pregnancy is associated with neonatal cardio-metabolic makers including leptin, glucose, and HDL-c at delivery, independent of neonatal adiposity. Our results suggest that intrauterine exposure to maternal obesity influences metabolic processes beyond fetal growth and fat accretion. PMID:26055075

  3. Effect of cryoprotectants on the porosity and stability of insulin-loaded PLGA nanoparticles after freeze-drying

    PubMed Central

    Fonte, Pedro; Soares, Sandra; Costa, Ana; Andrade, José Carlos; Seabra, Vítor; Reis, Salette; Sarmento, Bruno

    2012-01-01

    PLGA nanoparticles are useful to protect and deliver proteins in a localized or targeted manner, with a long-term systemic delivery pattern intended to last for a period of time, depending on polymer bioerosion and biodegradability. However, the principal concern regarding these carriers is the hydrolytic instability of polymer in aqueous suspension. Freeze-drying is a commonly used method to stabilize nanoparticles, and cryoprotectants may be also used, to even increase its physical stability. The aim of the present work was to analyze the influence of cryoprotectants on nanoparticle stability and porosity after freeze-drying, which may influence protein release and stability. It was verified that freeze-drying significantly increased the number of pores on PLGA-NP surface, being more evident when cryoprotectants are added. The presence of pores is important in a lyophilizate to facilitate its reconstitution in water, although this may have consequences to protein release and stability. The release profile of insulin encapsulated into PLGA-NP showed an initial burst in the first 2 h and a sustained release up to 48 h. After nanoparticles freeze-drying the insulin release increased about 18% in the first 2 h due to the formation of pores, maintaining a sustained release during time. After freeze-drying with cryoprotectants, the amount of insulin released was higher for trehalose and lower for sucrose, glucose, fructose and sorbitol comparatively to freeze-dried PLGA-NP with no cryoprotectant added. Besides the porosity, the ability of cryoprotectants to be adsorbed on the nanoparticles surface may also play an important role on insulin release and stability. PMID:23507897

  4. The bioartificial pancreas (BAP): Biological, chemical and engineering challenges.

    PubMed

    Iacovacci, Veronica; Ricotti, Leonardo; Menciassi, Arianna; Dario, Paolo

    2016-01-15

    The bioartificial pancreas (BAP) represents a viable solution for the treatment of type 1 diabetes (T1D). By encapsulating pancreatic cells in a semipermeable membrane to allow nutrient, insulin and glucose exchange, the side effects produced by islets and whole organ transplantation-related immunosuppressive therapy can be circumvented. Several factors, mainly related to materials properties, capsule morphology and biological environment, play a key role in optimizing BAP systems. The BAP is an extremely complex delivery system for insulin. Despite considerable efforts, in some instances meeting with limited degree of success, a BAP capable of restoring physiological pancreas functions without the need for immunosuppressive drugs and of controlling blood glucose levels especially in large animal models and a few clinical trials, does not exist. The state of the art in terms of materials, fabrication techniques and cell sources, as well as the current status of commercial devices and clinical trials, are described in this overview from an interdisciplinary viewpoint. In addition, challenges to the creation of effective BAP systems are highlighted including future perspectives in terms of component integration from both a biological and an engineering viewpoint. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Insulin pump therapy with automated insulin suspension in response to hypoglycemia: reduction in nocturnal hypoglycemia in those at greatest risk.

    PubMed

    Choudhary, Pratik; Shin, John; Wang, Yongyin; Evans, Mark L; Hammond, Peter J; Kerr, David; Shaw, James A M; Pickup, John C; Amiel, Stephanie A

    2011-09-01

    To evaluate a sensor-augmented insulin pump with a low glucose suspend (LGS) feature that automatically suspends basal insulin delivery for up to 2 h in response to sensor-detected hypoglycemia. The LGS feature of the Paradigm Veo insulin pump (Medtronic, Inc., Northridge, CA) was tested for 3 weeks in 31 adults with type 1 diabetes. There were 166 episodes of LGS: 66% of daytime LGS episodes were terminated within 10 min, and 20 episodes lasted the maximum 2 h. LGS use was associated with reduced nocturnal duration ≤2.2 mmol/L in those in the highest quartile of nocturnal hypoglycemia at baseline (median 46.2 vs. 1.8 min/day, P = 0.02 [LGS-OFF vs. LGS-ON]). Median sensor glucose was 3.9 mmol/L after 2-h LGS and 8.2 mmol/L at 2 h after basal restart. Use of an insulin pump with LGS was associated with reduced nocturnal hypoglycemia in those at greatest risk and was well accepted by patients.

  6. Anti-cancer vaccination by transdermal delivery of antigen peptide-loaded nanogels via iontophoresis.

    PubMed

    Toyoda, Mao; Hama, Susumu; Ikeda, Yutaka; Nagasaki, Yukio; Kogure, Kentaro

    2015-04-10

    Transdermal vaccination with cancer antigens is expected to become a useful anti-cancer therapy. However, it is difficult to accumulate enough antigen in the epidermis for effective exposure to Langerhans cells because of diffusion into the skin and muscle. Carriers, such as liposomes and nanoparticles, may be useful for the prevention of antigen diffusion. Iontophoresis, via application of a small electric current, is a noninvasive and efficient technology for transdermal drug delivery. Previously, we succeeded in the iontophoretic transdermal delivery of liposomes encapsulating insulin, and accumulation of polymer-based nanoparticle nanogels in the stratum corneum of the skin. Therefore, in the present study, we examined the use of iontophoresis with cancer antigen gp-100 peptide KVPRNQDWL-loaded nanogels for anti-cancer vaccination. Iontophoresis resulted in the accumulation of gp-100 peptide and nanogels in the epidermis, and subsequent increase in the number of Langerhans cells in the epidermis. Moreover, tumor growth was significantly suppressed by iontophoresis of the antigen peptide-loaded nanogels. Thus, iontophoresis of the antigen peptide-loaded nanogels may serve as an effective transdermal delivery system for anti-cancer vaccination. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Pre-formulation and systematic evaluation of amino acid assisted permeability of insulin across in vitro buccal cell layers

    PubMed Central

    Iyire, Affiong; Alayedi, Maryam; Mohammed, Afzal R.

    2016-01-01

    The aim of this work was to investigate alternative safe and effective permeation enhancers for buccal peptide delivery. Basic amino acids improved insulin solubility in water while 200 and 400 μg/mL lysine significantly increased insulin solubility in HBSS. Permeability data showed a significant improvement in insulin permeation especially for 10 μg/mL of lysine (p < 0.05) and 10 μg/mL histidine (p < 0.001), 100 μg/mL of glutamic acid (p < 0.05) and 200 μg/mL of glutamic acid and aspartic acid (p < 0.001) without affecting cell integrity; in contrast to sodium deoxycholate which enhanced insulin permeability but was toxic to the cells. It was hypothesized that both amino acids and insulin were ionised at buccal cavity pH and able to form stable ion pairs which penetrated the cells as one entity; while possibly triggering amino acid nutrient transporters on cell surfaces. Evidence of these transport mechanisms was seen with reduction of insulin transport at suboptimal temperatures as well as with basal-to-apical vectoral transport, and confocal imaging of transcellular insulin transport. These results obtained for insulin are the first indication of a possible amino acid mediated transport of insulin via formation of insulin-amino acid neutral complexes by the ion pairing mechanism. PMID:27581177

  8. 1H NMR investigation of thermally triggered insulin release from poly(N-isopropylacrylamide) microgels.

    PubMed

    Nolan, Christine M; Gelbaum, Leslie T; Lyon, L Andrew

    2006-10-01

    We describe investigations of insulin release from thermoresponsive microgels using variable temperature (1)H NMR. Microgel particles composed of poly(N-isopropylacrylamide) were loaded with the peptide via a swelling technique, and this method was compared to simple equilibrium partitioning. Variable temperature (1)H NMR studies suggest that the swelling loading method results in enhanced entrapment of the peptide versus equilibrium partitioning. A centrifugation-loading assay supports this finding. Pseudo-temperature jump (1)H NMR measurements suggest that the insulin release rate is partially decoupled from microgel collapse. These types of direct release investigations could prove to be useful methods in the future design of controlled macromolecule drug delivery devices.

  9. Design of spray dried insulin microparticles to bypass deposition in the extrathoracic region and maximize total lung dose.

    PubMed

    Ung, Keith T; Rao, Nagaraja; Weers, Jeffry G; Huang, Daniel; Chan, Hak-Kim

    2016-09-25

    Inhaled drugs all too often deliver only a fraction of the emitted dose to the target lung site due to deposition in the extrathoracic region (i.e., mouth and throat), which can lead to increased variation in lung exposure, and in some instances increases in local and systemic side effects. For aerosol medications, improved targeting to the lungs may be achieved by tailoring the micromeritic properties of the particles (e.g., size, density, rugosity) to minimize deposition in the mouth-throat and maximize the total lung dose. This study evaluated a co-solvent spray drying approach to modulate particle morphology and dose delivery characteristics of engineered powder formulations of insulin microparticles. The binary co-solvent system studied included water as the primary solvent mixed with an organic co-solvent, e.g., ethanol. Factors such as the relative rate of evaporation of each component of a binary co-solvent mixture, and insulin solubility in each component were considered in selecting feedstock compositions. A water-ethanol co-solvent mixture with a composition range considered suitable for modulating particle shell formation during drying was selected for experimental investigation. An Alberta Idealized Throat model was used to evaluate the in vitro total lung dose of a series of spray dried insulin formulations engineered with different bulk powder properties and delivered with two prototype inhalers that fluidize and disperse powder using different principles. The in vitro total lung dose of insulin microparticles was improved and favored for powders with low bulk density and small primary particle size, with reduction of deposition in the extrathoracic region. The results demonstrated that a total lung dose >95% of the delivered dose can be achieved with engineered particles, indicating a high degree of lung targeting, almost completely bypassing deposition in the mouth-throat. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Hyperglycaemia attenuates in vivo reprogramming of pancreatic exocrine cells to beta cells in mice

    PubMed Central

    Cavelti-Weder, Claudia; Li, Weida; Zumsteg, Adrian; Stemann-Andersen, Marianne; Zhang, Yuemei; Yamada, Takatsugu; Wang, Max; Lu, Jiaqi; Jermendy, Agnes; Bee, Yong Mong; Bonner-Weir, Susan; Weir, Gordon C.; Zhou, Qiao

    2016-01-01

    Aims/hypothesis Reprogramming of pancreatic exocrine to insulin-producing cells by viral delivery of the genes encoding transcription factors neurogenin-3 (Ngn3), pancreas/duodenum homeobox protein 1 (Pdx1) and MafA is an efficient method for reversing diabetes in murine models. The variables that modulate reprogramming success are currently ill-defined. Methods Here, we assess the impact of glycaemia on in vivo reprogramming in a mouse model of streptozotocin-induced beta cell ablation, using subsequent islet transplantation or insulin pellet implantation for creation of groups with differing levels of glycaemia before viral delivery of transcription factors. Results We observed that hyperglycaemia significantly impaired reprogramming of exocrine to insulin-producing cells in their quantity, differentiation status and function. With hyperglycaemia, the reprogramming of acinar towards beta cells was less complete. Moreover, inflammatory tissue changes within the exocrine pancreas including macrophage accumulation were found, which may represent the tissue’s response to clear the pancreas from insufficiently reprogrammed cells. Conclusions/interpretation Our findings shed light on normoglycaemia as a prerequisite for optimal reprogramming success in a diabetes model, which might be important in other tissue engineering approaches and disease models, potentially facilitating their translational applications. PMID:26693711

  11. Hyperglycaemia attenuates in vivo reprogramming of pancreatic exocrine cells to beta cells in mice.

    PubMed

    Cavelti-Weder, Claudia; Li, Weida; Zumsteg, Adrian; Stemann-Andersen, Marianne; Zhang, Yuemei; Yamada, Takatsugu; Wang, Max; Lu, Jiaqi; Jermendy, Agnes; Bee, Yong Mong; Bonner-Weir, Susan; Weir, Gordon C; Zhou, Qiao

    2016-03-01

    Reprogramming of pancreatic exocrine to insulin-producing cells by viral delivery of the genes encoding transcription factors neurogenin-3 (Ngn3), pancreas/duodenum homeobox protein 1 (Pdx1) and MafA is an efficient method for reversing diabetes in murine models. The variables that modulate reprogramming success are currently ill-defined. Here, we assess the impact of glycaemia on in vivo reprogramming in a mouse model of streptozotocin-induced beta cell ablation, using subsequent islet transplantation or insulin pellet implantation for creation of groups with differing levels of glycaemia before viral delivery of transcription factors. We observed that hyperglycaemia significantly impaired reprogramming of exocrine to insulin-producing cells in their quantity, differentiation status and function. With hyperglycaemia, the reprogramming of acinar towards beta cells was less complete. Moreover, inflammatory tissue changes within the exocrine pancreas including macrophage accumulation were found, which may represent the tissue's response to clear the pancreas from insufficiently reprogrammed cells. Our findings shed light on normoglycaemia as a prerequisite for optimal reprogramming success in a diabetes model, which might be important in other tissue engineering approaches and disease models, potentially facilitating their translational applications.

  12. Managing type 1 diabetes mellitus in pregnancy--from planning to breastfeeding.

    PubMed

    Ringholm, Lene; Mathiesen, Elisabeth R; Kelstrup, Louise; Damm, Peter

    2012-11-01

    Type 1 diabetes mellitus in pregnant women increases the risk of adverse outcomes for mother and offspring. Careful preconception counselling and screening is important, with particular focus on glycaemic control, indications for antihypertensive therapy, screening for diabetic nephropathy, diabetic retinopathy and thyroid dysfunction, as well as review of other medications. Supplementation with folic acid should be initiated before conception in order to minimize the risk of fetal malformations. Obtaining and maintaining tight control of blood glucose and blood pressure before and during pregnancy is crucial for optimizing outcomes; however, the risk of severe hypoglycaemia during pregnancy is a major obstacle. Although pregnancy does not result in deterioration of kidney function in women with diabetic nephropathy and normal serum creatinine levels, pregnancy complications such as pre-eclampsia and preterm delivery are more frequent in these women than in women with T1DM and normal kidney function. Rapid-acting insulin analogues are considered safe to use in pregnancy and studies on long-acting insulin analogues have provided reassuring results. Immediately after delivery the insulin requirement declines to approximately 60% of the prepregnancy dose, and remains 10% lower than before pregnancy during breastfeeding.

  13. Nanomaterial Solutions for the Protection of Insulin Producing Beta Cells

    NASA Astrophysics Data System (ADS)

    Atchison, Nicole Ann

    Islet transplantation is a promising treatment for type 1 diabetes. However, even with the many successes, islet transplantation has yet to reach its full potential. Limited islet sources, loss of cell viability during isolation and culture, and post-transplant graft loss are a few of the issues preventing extensive use of islet transplantation. The application of biomaterial systems to alleviate some of the stresses affecting islet viability has led to improvements in isolation and transplantation outcomes, but problems persist. In this work we approach two distinct issues affecting islet viability; ischemic conditions and immunological attack post-transplant. Ischemic conditions have been linked to a loss of islet graft function and occur during organ preservation, islet isolation and culture, and after islets are transplanted. We show that liposomal delivery of adenosine triphosphate (ATP) to beta cells can limit cell death and loss of function in ischemic conditions. We demonstrate that by functionalizing liposomes with the fibronectin-mimetic peptide PR_b, delivery of liposomes to porcine islets and rat beta cells is increased compared to nontargeted controls. Additionally, liposomes are shown to protect by providing both ATP and lipids to the ischemic cells. The delivery of ATP was investigated here but application of PR_b functionalized liposomes could be extended to other interesting cargos as well. The second area of investigation involves encapsulation of islets with silica nanoparticles to create a permselective barrier. Silica nanoparticles are an interesting material for encapsulation given their ability to be fine-tuned and further functionalized. We demonstrate that size-tunable, fluorescent silica nanoparticles can be assembled layer-by-layer on the surface of cells and that silica nanoparticle encapsulated islets are able to secrete insulin in response to a glucose challenge.

  14. Insulin pump treatment in children and adolescents with type 1 diabetes.

    PubMed

    Hofer, S; Meraner, D; Koehle, J

    2012-08-01

    Within children and adolescents with type 1 diabetes insulin pump treatment is of increasing interest. Frequency of insulin pump therapy shows a rapid and steep increase in toddlers and young children. Insulin pumps allow a close to physiologic insulin delivery due to basal rates programmed over 24 hours with circadian rhythms taken into account. Furthermore, another advantage of technical devices as insulin pumps is the application of extremely small amounts of insulin, as needed in very young children, with the possibility of titration of infusion rates down to 0.01E/h. Dawn Phenomenon and hypoglycemic events are main indications for insulin pump treatment in children and adolescents. A significant reduction of severe hypoglycemia, especially nocturnal hypoglycemia was shown, whereas a reduction of HbA1c and an improvement of metabolic control has been reported in short term and in some but not all long term studies. Ketoacidosis rate did not increase in insulin pump therapy. Complications due to continuous subcutaneous insulin infusion, like local infections and dermatological changes are frequent but were not associated with glycemic control and did not lead to discontinuation of insulin pump treatment. Pump discontinuation rate in general is low, varying from 1% in very young children up to 6% in pubertal adolescent girls. Insulin pump treatment was shown to be safe and efficient and the simplicity of handling the devices as well as an improvement of quality of life may explain the rapid increase of pump treatment in young children and adolescents with type 1 diabetes.

  15. The disposition index does not reflect β-cell function in IGT subjects treated with pioglitazone.

    PubMed

    DeFronzo, Ralph A; Tripathy, Devjit; Abdul-Ghani, Muhammad; Musi, Nicolas; Gastaldelli, Amalia

    2014-10-01

    The insulin secretion/insulin resistance (IR) (disposition) index (ΔI/ΔG ÷ IR, where Δ is change from baseline, I is insulin, and G is glucose) is commonly used as a measure of β-cell function. This relationship is curvilinear and becomes linear when log transformed. ΔI is determined by 2 variables: insulin secretion rate (ISR) and metabolic clearance of insulin. We postulated that the characteristic curvilinear relationship would be lost if Δ plasma C-peptide (ΔCP) (instead of Δ plasma insulin) was plotted against insulin sensitivity. A total of 441 individuals with impaired glucose tolerance (IGT) from ACT NOW received an oral glucose tolerance test and were randomized to pioglitazone or placebo for 2.4 years. Pioglitazone reduced IGT conversion to diabetes by 72% (P < .0001). ΔI/ΔG vs the Matsuda index of insulin sensitivity showed the characteristic curvilinear relationship. However, when ΔCP/ΔG or ΔISR/ΔG was plotted against the Matsuda index, the curvilinear relationship was completely lost. This discordance was explained by 2 distinct physiologic effects that altered plasma insulin response in opposite directions: 1) increased ISR and 2) augmented metabolic clearance of insulin. The net result was a decline in the plasma insulin response to hyperglycemia during the oral glucose tolerance test. These findings demonstrate a physiologic control mechanism wherein the increase in ISR ensures adequate insulin delivery into the portal circulation to suppress hepatic glucose production while delivering a reduced but sufficient amount of insulin to peripheral tissues to maintain the pioglitazone-mediated improvement in insulin sensitivity without excessive hyperinsulinemia. These results demonstrate the validity of the disposition index when relating the plasma insulin response to insulin sensitivity but underscore the pitfall of this index when drawing conclusions about β-cell function, because insulin secretion declined despite an increase in the plasma insulin response.

  16. Does pen help? A real-world outcomes study of switching from vial to disposable pen among insulin glargine-treated patients with type 2 diabetes mellitus.

    PubMed

    Xie, Lin; Zhou, Steve; Wei, Wenhui; Gill, Jasvinder; Pan, Chunshen; Baser, Onur

    2013-03-01

    The study was designed to evaluate real-world data on clinical and economic outcome differences between patients with type 2 diabetes mellitus (T2DM) who use insulin glargine with vial-and-syringe delivery and those who switch to pen administration. This retrospective study analyzed medical and pharmacy claims information from the national managed-care IMPACT(®) database (Ingenix Inc., Salt Lake City, UT). Adults with T2DM treated with insulin glargine were evaluated. Clinical and economic outcomes over 1 year were compared between individuals who had converted from administering glargine via vial-and-syringe to the SoloSTAR(®) (sanofi-aventis U.S., Bridgewater, NJ) pen (Switchers) and patients who continued to use vial-and-syringe administration (Continuers). Patients from each cohort were matched using propensity score matching for a comparison sample. In total, 3,893 eligible patients were identified (665 Switchers and 3,228 Continuers), with a matched cohort with 603 patients in each group. Baseline characteristics were similar between groups. One-year treatment persistence was significantly higher with Switchers versus Continuers (65.3% vs. 49.8%; P<0.0001). Medication possession ratio was also significantly higher among Switchers (0.79 vs. 0.76; P=0.0173). Insulin use and glycemic control were similar between groups. Healthcare utilization and total costs were also similar between groups. Higher prescription costs among Switchers were offset by lower overall and diabetes-related outpatient and inpatient costs. Switching from insulin glargine vial-and-syringe administration to pen delivery resulted in improved treatment adherence and persistence, with comparable clinical and economic outcomes.

  17. Earth benefits from space life sciences

    NASA Technical Reports Server (NTRS)

    Garshnek, V.; Nicogossian, A. E.; Griffiths, L.

    1988-01-01

    The applications to medicine of various results from space exploration are examined. Improvements have been made in the management of cardiovascular disease, in particular the use of the ultrasonic scanner to image arteries in three dimensions, the use of excimer lasers to disrupt arterial plaques in coronary blood vessels, and the use of advanced electrodes for cardiac monitoring. A bone stiffness analyzer has helped to diagnose osteoporosis and aid in its treatment. An automated light microscope system is used for chromosome analysis, and an X-ray image intensifier called Lixiscope is used in emergency medical care. An advanced portable defibrillator has been developed for the heart, and an insulin delivery system has been derived from space microminiaturization techniques.

  18. Multifunctional Nanocarriers for diagnostics, drug delivery and targeted treatment across blood-brain barrier: perspectives on tracking and neuroimaging.

    PubMed

    Bhaskar, Sonu; Tian, Furong; Stoeger, Tobias; Kreyling, Wolfgang; de la Fuente, Jesús M; Grazú, Valeria; Borm, Paul; Estrada, Giovani; Ntziachristos, Vasilis; Razansky, Daniel

    2010-03-03

    Nanotechnology has brought a variety of new possibilities into biological discovery and clinical practice. In particular, nano-scaled carriers have revolutionalized drug delivery, allowing for therapeutic agents to be selectively targeted on an organ, tissue and cell specific level, also minimizing exposure of healthy tissue to drugs. In this review we discuss and analyze three issues, which are considered to be at the core of nano-scaled drug delivery systems, namely functionalization of nanocarriers, delivery to target organs and in vivo imaging. The latest developments on highly specific conjugation strategies that are used to attach biomolecules to the surface of nanoparticles (NP) are first reviewed. Besides drug carrying capabilities, the functionalization of nanocarriers also facilitate their transport to primary target organs. We highlight the leading advantage of nanocarriers, i.e. their ability to cross the blood-brain barrier (BBB), a tightly packed layer of endothelial cells surrounding the brain that prevents high-molecular weight molecules from entering the brain. The BBB has several transport molecules such as growth factors, insulin and transferrin that can potentially increase the efficiency and kinetics of brain-targeting nanocarriers. Potential treatments for common neurological disorders, such as stroke, tumours and Alzheimer's, are therefore a much sought-after application of nanomedicine. Likewise any other drug delivery system, a number of parameters need to be registered once functionalized NPs are administered, for instance their efficiency in organ-selective targeting, bioaccumulation and excretion. Finally, direct in vivo imaging of nanomaterials is an exciting recent field that can provide real-time tracking of those nanocarriers. We review a range of systems suitable for in vivo imaging and monitoring of drug delivery, with an emphasis on most recently introduced molecular imaging modalities based on optical and hybrid contrast, such as fluorescent protein tomography and multispectral optoacoustic tomography. Overall, great potential is foreseen for nanocarriers in medical diagnostics, therapeutics and molecular targeting. A proposed roadmap for ongoing and future research directions is therefore discussed in detail with emphasis on the development of novel approaches for functionalization, targeting and imaging of nano-based drug delivery systems, a cutting-edge technology poised to change the ways medicine is administered.

  19. Postpartum changes in maternal and infant erythrocyte fatty acids are likely to be driven by restoring insulin sensitivity and DHA status.

    PubMed

    Kuipers, Remko S; Luxwolda, Martine F; Sango, Wicklif S; Kwesigabo, Gideon; Velzing-Aarts, Francien V; Dijck-Brouwer, D A Janneke; Muskiet, Frits A J

    2011-06-01

    Perinatal changes in maternal glucose and lipid fluxes and de novo lipogenesis (DNL) are driven by hormones and nutrients. Docosahexaenoic acid (DHA) reduces, whereas insulin augments, nuclear abundance of sterol-regulatory-element-binding-protein-1 (SREBP-1), which promotes DNL, stearoyl-CoA-desaturase (SCD, also Δ9-desaturase), fatty acid-(FA)-elongation (Elovl) and FA-desaturation (FADS). Decreasing maternal insulin sensitivity with advancing gestation and compensatory hyperinsulinemia cause augmented postprandial glucose levels, adipose tissue lipolysis and hepatic glucose- and VLDL-production. Hepatic VLDL is composed of dietary, body store and DNL derived FA. Decreasing insulin sensitivity increases the contribution of FA from hepatic-DNL in VLDL-triacylglycerols, and consequently saturated-FA and monounsaturated-FA (MUFA) in maternal serum lipids increase during pregnancy. Although other authors described changes in maternal serum and RBC essential-FA (EFA) after delivery, none went into detail about the changes in non-EFA and the mechanisms behind -and/or functions of- the observed changes. Postpartum FA-changes result from changing enzymatic activities that are influenced by the changing hormonal milieu after delivery and DHA-status. We studied FA-profiles and FA-ratios (as indices for enzymatic activities) of maternal and infant RBC at delivery and after 3 months exclusive breastfeeding in three populations with increasing freshwater-fish intakes. DNL-, SCD- and FADS2-activities decreased after delivery. Elongation-6 (Elovl-6)- and FADS1-activities increased. The most pronounced postpartum changes for mothers were increases in 18:0, linoleic (LA), arachidonic acid (AA) and decreases in 16:0, 18:1ω9 and DHA; and for infants increases in 18:1ω9, 22:5ω3, LA and decreases in 16:0 and AA. Changes were in line with the literature. Postpartum increases in 18:0, and decreases in 16:0 and 18:1ω9, might derive from reduced insulin-promoted DNL-activity, with more reduced SCD- than Elovl-activity that leaves more 16:0 to be converted to 18:0 (Elovl-activity) than to MUFA (SCD-activity). Postpartum changes in ΣDNL, saturated-FA and MUFA related negatively to RBC-DHA. This concurs with suppression of both SCD- and Elovl-6 activities by DHA, through its influence on SREBP. Infant MUFA and LA increased at expense of their mothers. Sustained transport might be important for myelination (MUFA) and skin barrier development (LA). Maternal postpartum decreases in FADS2-, and apparent increases in FADS1-activity, together with increases in LA, AA, and 22:5ω3, but decrease in DHA, confirm that FADS2 is rate limiting in EFA-desaturation. Maternal LA and AA increases might be the result of rerouting from transplacental transfer to the incorporation into milk lipids and discontinued placental AA-utilization. Perinatal changes in maternal and infant FA status may be strongly driven by changing insulin sensitivity and DHA status. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes.

    PubMed

    Spaic, Tamara; Driscoll, Marsha; Raghinaru, Dan; Buckingham, Bruce A; Wilson, Darrell M; Clinton, Paula; Chase, H Peter; Maahs, David M; Forlenza, Gregory P; Jost, Emily; Hramiak, Irene; Paul, Terri; Bequette, B Wayne; Cameron, Faye; Beck, Roy W; Kollman, Craig; Lum, John W; Ly, Trang T

    2017-03-01

    The objective of this study was to determine the safety, feasibility, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system compared with predictive low-glucose insulin suspension (PLGS) alone in overnight glucose control. A 42-night trial was conducted in 30 individuals with type 1 diabetes in the age range 15-45 years. Participants were randomly assigned each night to either PHHM or PLGS and were blinded to the assignment. The system suspended the insulin pump on both the PHHM and PLGS nights for predicted hypoglycemia but delivered correction boluses for predicted hyperglycemia on PHHM nights only. The primary outcome was the percentage of time spent in a sensor glucose range of 70-180 mg/dL during the overnight period. The addition of automated insulin delivery with PHHM increased the time spent in the target range (70-180 mg/dL) from 71 ± 10% during PLGS nights to 78 ± 10% during PHHM nights ( P < 0.001). The average morning blood glucose concentration improved from 163 ± 23 mg/dL after PLGS nights to 142 ± 18 mg/dL after PHHM nights ( P < 0.001). Various sensor-measured hypoglycemic outcomes were similar on PLGS and PHHM nights. All participants completed 42 nights with no episodes of severe hypoglycemia, diabetic ketoacidosis, or other study- or device-related adverse events. The addition of a predictive hyperglycemia minimization component to our existing PLGS system was shown to be safe, feasible, and effective in overnight glucose control. © 2017 by the American Diabetes Association.

  1. A hollow stainless steel microneedle array to deliver insulin to a diabetic rat

    NASA Astrophysics Data System (ADS)

    Vinayakumar, K. B.; Kulkarni, Prachit G.; Nayak, M. M.; Dinesh, N. S.; Hegde, Gopalkrishna M.; Ramachandra, S. G.; Rajanna, K.

    2016-06-01

    A novel fabrication process has been described for the development of a hollow stainless steel microneedle array using femto second laser micromachining. Using this method, a complicated microstructure can be fabricated in a single process step without using masks. The mechanical stability of the fabricated microneedle array was measured for axial and transverse loading. Skin histology was carried out to study the microneedle penetration into the rat skin. Fluid flow through the microneedle array was studied for different inlet pressures. The packaging of the microneedle array, to protect the microneedle bore blockage from dust and other atmospheric contaminations, was also considered. Finally, the microneedle array was tested and studied in vivo for insulin delivery to a diabetic rat. The results obtained were compared with the standard subcutaneous delivery with the same dose rate and were found to be in good agreement.

  2. A Review of the Clinical Efficacy and Safety of Insulin Degludec and Glargine 300 U/mL in the Treatment of Diabetes Mellitus.

    PubMed

    Woo, Vincent C

    2017-08-01

    The treatment of type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM) using insulin is not ideal at this time. Despite advances made with basal insulin analogues, many individuals achieve less than optimal glycemic control or are at risk for hypoglycemia. Currently available basal insulin analogues do not deliver steady, peakless, continuous insulin for >24 hours and are associated with adverse events, including hypoglycemia. The objective of this paper was to review the clinical efficacy and safety of upcoming long-acting insulin analogues such as insulin degludec and insulin glargine 300 U/mL (Gla-300). A comprehensive literature search of PubMed and Google Scholar was conducted from 1966 to 2015. The search included randomized controlled trials that specifically assessed the efficacy and safety of insulin degludec and Gla-300 in patients with T1DM and T2DM. The efficacy of insulin degludec and Gla-300 in achieving glycemic control has been reported in clinical trials in adults with T1DM and T2DM. Not only did a large number of patients succeed in meeting glycosylated hemoglobin targets, but they also experienced reductions in hypoglycemic events. These 2 therapies are associated with a reduced risk of nocturnal hypoglycemia and are generally well tolerated. The long-acting insulin analogues insulin degludec and Gla-300 are promising therapies in the treatment of T1DM and T2DM. Their improved insulin delivery for >24 hours offers glycemic control with a good safety profile. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  3. Association of Adverse Pregnancy Outcomes With Glyburide vs Insulin in Women With Gestational Diabetes.

    PubMed

    Camelo Castillo, Wendy; Boggess, Kim; Stürmer, Til; Brookhart, M Alan; Benjamin, Daniel K; Jonsson Funk, Michele

    2015-05-01

    Glyburide is thought to be safe for use during pregnancy for treatment of gestational diabetes mellitus (GDM). However, there are limited data on the effectiveness of glyburide when compared with insulin as used in a real-world setting. To estimate the risk of adverse maternal and neonatal outcomes in women with GDM treated with glyburide compared with insulin. Retrospective cohort study of a population-based cohort from a nationwide US employer-based insurance claims database from January 1, 2000, to December 31, 2011. We identified women with GDM and their newborns. We excluded those with type 1 or 2 diabetes and those younger than 15 years or older than 45 years. Treatment with glyburide or insulin during pregnancy within 150 days before delivery. We used binomial regression to estimate risk ratios (RRs) and risk differences with 95% confidence intervals for the association of glyburide with diagnosis codes for obstetric trauma, cesarean delivery, birth injury, preterm birth, hypoglycemia, respiratory distress, jaundice, large for gestational age, and hospitalization in the neonatal intensive care unit. Inverse probability of treatment weights were used to adjust for maternal characteristics that differed between the treatment groups. Among 110,879 women with GDM, 9173 women (8.3%) were treated with glyburide (n = 4982) or insulin (n = 4191). After adjusting for differences at baseline, newborns of women treated with glyburide were at increased risk for neonatal intensive care unit admission (RR = 1.41; 95% CI, 1.23-1.62), respiratory distress (RR = 1.63; 95% CI, 1.23-2.15), hypoglycemia (RR = 1.40; 95% CI, 1.00-1.95), birth injury (RR = 1.35; 95% CI, 1.00-1.82), and large for gestational age (RR = 1.43; 95% CI, 1.16-1.76) compared with those treated with insulin; they were not at increased risk for obstetric trauma (RR = 0.92; 95% CI, 0.71-1.20), preterm birth (RR = 1.06; 95% CI, 0.93-1.21), or jaundice (RR = 0.96; 95% CI, 0.48-1.91). The risk of cesarean delivery was 3% lower in the glyburide group (adjusted RR = 0.97; 95% CI, 0.93-1.00). The risk difference associated with glyburide was 2.97% (95% CI, 1.82-4.12) for neonatal intensive care unit admission, 1.41% (95% CI, 0.61-2.20) for large for gestational age, and 1.11% (95% CI, 0.50-1.72) for respiratory distress. Newborns from privately insured mothers treated with glyburide were more likely to experience adverse outcomes than those from mothers treated with insulin. Given the widespread use of glyburide, further investigation of these differences in pregnancy outcomes is a public health priority.

  4. Gestational Protein Restriction Impairs Insulin-Regulated Glucose Transport Mechanisms in Gastrocnemius Muscles of Adult Male Offspring

    PubMed Central

    Blesson, Chellakkan S.; Sathishkumar, Kunju; Chinnathambi, Vijayakumar

    2014-01-01

    Type II diabetes originates from various genetic and environmental factors. Recent studies showed that an adverse uterine environment such as that caused by a gestational low-protein (LP) diet can cause insulin resistance in adult offspring. The mechanism of insulin resistance induced by gestational protein restriction is not clearly understood. Our aim was to investigate the role of insulin signaling molecules in gastrocnemius muscles of gestational LP diet–exposed male offspring to understand their role in LP-induced insulin resistance. Pregnant Wistar rats were fed a control (20% protein) or isocaloric LP (6%) diet from gestational day 4 until delivery and a normal diet after weaning. Only male offspring were used in this study. Glucose and insulin responses were assessed after a glucose tolerance test. mRNA and protein levels of molecules involved in insulin signaling were assessed at 4 months in gastrocnemius muscles. Muscles were incubated ex vivo with insulin to evaluate insulin-induced phosphorylation of insulin receptor (IR), Insulin receptor substrate-1, Akt, and AS160. LP diet-fed rats gained less weight than controls during pregnancy. Male pups from LP diet–fed mothers were smaller but exhibited catch-up growth. Plasma glucose and insulin levels were elevated in LP offspring when subjected to a glucose tolerance test; however, fasting levels were comparable. LP offspring showed increased expression of IR and AS160 in gastrocnemius muscles. Ex vivo treatment of muscles with insulin showed increased phosphorylation of IR (Tyr972) in controls, but LP rats showed higher basal phosphorylation. Phosphorylation of Insulin receptor substrate-1 (Tyr608, Tyr895, Ser307, and Ser318) and AS160 (Thr642) were defective in LP offspring. Further, glucose transporter type 4 translocation in LP offspring was also impaired. A gestational LP diet leads to insulin resistance in adult offspring by a mechanism involving inefficient insulin-induced IR, Insulin receptor substrate-1, and AS160 phosphorylation and impaired glucose transporter type 4 translocation. PMID:24797633

  5. Polymers for the stabilization and delivery of proteins topically and per os to the insect hemocoel through conjugation with aliphatic polyethylene glycol.

    PubMed

    Jeffers, Laura A; Shen, Hongyan; Bissinger, Brooke W; Khalil, Sayed; Gunnoe, T Brent; Roe, R Michael

    2014-10-01

    Co-feeding of aliphatic polyethylene glycol (PEG), phospholipase A2, anionic and ionic detergents, and amphipathic glycoside with bovine serum albumin (BSA) as a model protein to fourth stadium tobacco budworms, Heliothis virescens, did not affect the levels of BSA in the hemolymph. Covalent conjugation of small proteins like the decapeptide trypsin modulating oostatic factor (TMOF) to polyethylene glycol was previously shown to protect the peptide from protease attack and enhance its accumulation in the insect hemocoel. Whether this polymer chemistry could do the same for larger proteins was examined. The chemistry for the synthesis of polydispersed aliphatic PEG350-insulin and monodispersed aliphatic PEG333-insulin are described herein. Insulin was used for this synthesis and not BSA to better control conjugation among the available free amine groups. When PEGylated insulin or free insulin were fed in artificial diet to fifth stadium budworms, greater concentrations of insulin using the PEGylated variants were found in the hemolymph than when free insulin was used (a 6.7 and 7.3-fold increase for the PEG350 and PEG333 conjugates, respectively). When insulin is topically applied to the dorsum of H. virescens, no insulin is found in the hemolymph. However, after topical application of the PEGylated insulins, PEG350-insulin and PEG333-insulin were detected in the hemolymph. After injections of insulin into the hemocoel of fourth stadium H. virescens, insulin is completely cleared from the hemolymph in 120min. In comparison, PEG350-insulin and PEG333-insulin were present in the hemolymph for 300 and 240min after injection, respectively, translating to a 3.3 and 2.7-fold increase in the length of time insulin remains in the hemolymph after injection. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Globular adiponectin ameliorates metabolic insulin resistance via AMPK-mediated restoration of microvascular insulin responses

    PubMed Central

    Zhao, Lina; Fu, Zhuo; Wu, Jing; Aylor, Kevin W; Barrett, Eugene J; Cao, Wenhong; Liu, Zhenqi

    2015-01-01

    Abstract Hypoadiponectinaemia is closely associated with endothelial dysfunction and insulin resistance, and microvasculature plays a critical role in the regulation of insulin action in muscle. Here we tested whether adiponectin replenishment could improve metabolic insulin sensitivity in male rats fed a high-fat diet (HFD) via the modulation of microvascular insulin responses. Male Sprague–Dawley rats were fed either a HFD or low-fat diet (LFD) for 4 weeks. Small resistance artery myograph changes in tension, muscle microvascular recruitment and metabolic response to insulin were determined. Compared with rats fed a LFD, HFD feeding abolished the vasodilatory actions of globular adiponectin (gAd) and insulin on pre-constricted distal saphenous arteries. Pretreatment with gAd improved insulin responses in arterioles isolated from HFD rats, which was blocked by AMP-activated protein kinase (AMPK) inhibition. Similarly, HFD abolished microvascular responses to either gAd or insulin and decreased insulin-stimulated glucose disposal by ∼60%. However, supplementing gAd fully rescued insulin’s microvascular action and significantly improved the metabolic responses to insulin in HFD male rats and these actions were abolished by inhibition of either AMPK or nitric oxide production. We conclude that HFD induces vascular adiponectin and insulin resistance but gAd administration can restore vascular insulin responses and improve insulin’s metabolic action via an AMPK- and nitric oxide-dependent mechanism in male rats. Key points Adiponectin is an adipokine with anti-inflammatory and anti-diabetic properties. Hypoadiponectinaemia is closely associated with endothelial dysfunction and insulin resistance in obesity and diabetes. Insulin resistance is present in muscle microvasculature and this may contribute to decreased insulin delivery to, and action in, muscle. In this study we examined whether adiponectin ameliorates metabolic insulin resistance by affecting muscle microvascular recruitment. We demonstrated that a high-fat diet induces vascular adiponectin and insulin resistance but globular adiponectin administration can restore vascular insulin responses and improve insulin’s metabolic action via an AMPK- and nitric oxide-dependent mechanism. This suggests that globular adiponectin might have a therapeutic potential for improving insulin resistance and preventing cardiovascular complications in patients with diabetes via modulation of microvascular insulin responses. PMID:26108677

  7. Glycoproteins functionalized natural and synthetic polymers for prospective biomedical applications: A review.

    PubMed

    Tabasum, Shazia; Noreen, Aqdas; Kanwal, Arooj; Zuber, Mohammad; Anjum, Muhammad Naveed; Zia, Khalid Mahmood

    2017-05-01

    Glycoproteins have multidimensional properties such as biodegradability, biocompatibility, non-toxicity, antimicrobial and adsorption properties; therefore, they have wide range of applications. They are blended with different polymers such as chitosan, carboxymethyl cellulose (CMC), polyvinyl pyrrolidone (PVP), polycaprolactone (PCL), heparin, polystyrene fluorescent nanoparticles (PS-NPs) and carboxyl pullulan (PC) to improve their properties like thermal stability, mechanical properties, resistance to pH, chemical stability and toughness. Considering the versatile charateristics of glycoprotein based polymers, this review sheds light on synthesis and characterization of blends and composites of glycoproteins, with natural and synthetic polymers and their potential applications in biomedical field such as drug delivery system, insulin delivery, antimicrobial wound dressing uses, targeting of cancer cells, development of anticancer vaccines, development of new biopolymers, glycoproteome research, food product and detection of dengue glycoproteins. All the technical scientific issues have been addressed; highlighting the recent advancement. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Droplet-born air blowing: novel dissolving microneedle fabrication.

    PubMed

    Kim, Jung Dong; Kim, Miroo; Yang, Huisuk; Lee, Kwang; Jung, Hyungil

    2013-09-28

    The microneedle-mediated drug delivery system has been developed to provide painless self-administration of drugs in a patient-friendly manner. Current dissolving microneedle fabrication methods, however, require harsh conditions for biological drugs and also have problems standardizing the drug dose. Here, we suggested the droplet-born air blowing (DAB) method, which provides gentle (4-25 °C) and fast (≤10min) microneedle fabrication conditions without drug loss. The amount of drug in the microneedle can be controlled by the pressure and time of droplet dispenser and the air blowing shapes this droplet to the microneedle, providing a force sufficient to penetrate skin. Also, the introduction of a base structure of two layered DAB-microneedle could provide complete drug delivery without wasting of drug. The DAB-based insulin loaded microneedle shows similar bioavailability (96.6±2.4%) and down regulation of glucose level compared with subcutaneous injection. We anticipate that DAB described herein will be suitable to design dissolving microneedles for use in biological drug delivery to patients. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Insulin analogs for the treatment of diabetes mellitus: therapeutic applications of protein engineering.

    PubMed

    Berenson, Daniel F; Weiss, Allison R; Wan, Zhu-Li; Weiss, Michael A

    2011-12-01

    The engineering of insulin analogs represents a triumph of structure-based protein design. A framework has been provided by structures of insulin hexamers. Containing a zinc-coordinated trimer of dimers, such structures represent a storage form of the active insulin monomer. Initial studies focused on destabilization of subunit interfaces. Because disassembly facilitates capillary absorption, such targeted destabilization enabled development of rapid-acting insulin analogs. Converse efforts were undertaken to stabilize the insulin hexamer and promote higher-order self-assembly within the subcutaneous depot toward the goal of enhanced basal glycemic control with reduced risk of hypoglycemia. Current products either operate through isoelectric precipitation (insulin glargine, the active component of Lantus(®); Sanofi-Aventis) or employ an albumin-binding acyl tether (insulin detemir, the active component of Levemir(®); Novo-Nordisk). To further improve pharmacokinetic properties, modified approaches are presently under investigation. Novel strategies have recently been proposed based on subcutaneous supramolecular assembly coupled to (a) large-scale allosteric reorganization of the insulin hexamer (the TR transition), (b) pH-dependent binding of zinc ions to engineered His-X(3)-His sites at hexamer surfaces, or (c) the long-range vision of glucose-responsive polymers for regulated hormone release. Such designs share with wild-type insulin and current insulin products a susceptibility to degradation above room temperature, and so their delivery, storage, and use require the infrastructure of an affluent society. Given the global dimensions of the therapeutic supply chain, we envisage that concurrent engineering of ultra-stable protein analog formulations would benefit underprivileged patients in the developing world.

  10. [THE CHANGES OF NOCICEPTIVE THRESHOLD AND ACTIVITY OF THE ADENYLYL CYCLASE SYSTEM IN THE SKELETAL MUSCLES OF RATS WITH ACUTE AND MILD TYPE 1 DIABETES MELLITUS ].

    PubMed

    Shipilov, V N; Trost, A M; Chistyakova, O V; Derkach, K V; Shpakov, A O

    2016-02-01

    Diabetic peripheral neuropathy (DPN) is one of the most common complications of the type 1 diabetes mellitus (DM1). The aim of the work was to study the dynamics of a painful DPN and functional state of the hormone-sensitive ACSS in the skeletal muscles of rats with the models of acute and mild DM1, as well as the study of impact on them of insulin therapy with different ways of hormone delivery - intranasal and peripheral. In both models of DM1, the level of nociceptive threshold in rats decreased and the stimulatory effects of guanine nucleotides (GppNHp) and adrenergic agonists (isoproterenol, BRL-37344) on adenylyl cyclase (AC) activity were attenuated. The AC stimulating effect of relaxin decreased in animals with acute DM1, but in mild DM1, the decrease was insignificant. Peripheral administration of insulin in rats with acute DM1 increased the nociceptive threshold and partially restored the AC effect of ß 3-agonist BRL-37344. Intranasal administration of insulin in rats with DM1 also increased the nociceptive threshold and partially restored the basal and BRL-37344-stimulated AC activity in the skeletal muscles of diabetic animals. Thus, in the skeletal muscles of rats with acute and mild DM1 the nociceptive sensitivity and the functions of ACSS were disturbed, and they were partially restored by the treatment with peripheral (acute DM1) or intranasal (mild DM1) insulin.

  11. Nose-to-brain drug delivery: An update on clinical challenges and progress towards approval of anti-Alzheimer drugs.

    PubMed

    Agrawal, Mukta; Saraf, Swarnlata; Saraf, Shailendra; Antimisiaris, Sophia G; Chougule, Mahavir Bhupal; Shoyele, Sunday A; Alexander, Amit

    2018-07-10

    According to the Alzheimer Association Report (2017), Alzheimer's disease (AD) is the 6th primary cause of death in the USA, which affects nearly 5.5 million people. In the year 2017 itself, the cost of AD treatment in the USA has been reported to rise to $259 billion. This statistic shows the severity of the disease in the USA which is very much similar across the globe. On the other hand, the treatment remains limited to a few conventional oral medications (approved by FDA). These are mainly acting superficially from mild to the moderate AD. The therapeutic efficacy of the drug is not only affected by its reduced concentration in the brain owing to the existence of blood-brain-barrier (BBB) but also due to its low brain permeability. In this context, the intranasal (IN) route of drug administration has emerged as an alternative route over the systemic (oral and parenteral) drug delivery to the brain. The delivery of the drug via an IN route offers various advantages over systemic drug delivery system, as it directly delivers the drug into the brain via olfactory route. Presence of drug in the olfactory bulb, in turn, increases the drug bioavailability in the brain and reduces the drug degradation as well as wastage of the drug through` systemic clearance. However, there is also some limitation associated with IN like poor drug permeation through the nasal mucosa and mucociliary clearance. The delivery system various through novel strategies (nano drug carrier system, colloidal carriers, mucoadhesive devices, controlled delivery system, pro-drug, etc.) are adapted to overcome the above-stated limitations. Although, after all, such successful research claims, very few of the nose-to-brain drug delivery of anti-AD drugs have gained market approval due to lack of sufficient clinical evidence. Onzetra Xsail® is one such marketed preparations approved for IN delivery used for the treatment of a brain disorder; migraine. In the field of patents also, no work is found which could present sufficient experimental findings to support its clinical safety profile. It also underlines the fact that majority of work related to the nose-to-brain delivery of anti-AD drugs is limited only up to preclinical studies. In this review article, we have discussed the latest works on various novel formulations loaded with various anti-Alzheimer agents. These agents include galantamine, deferoxamine, tacrine, tarenflurbil, rivastigmine, risperidone, curcumin, quercetin, piperine, insulin, etc. and various peptides towards the development of a promising IN drug delivery system for the treatment of AD. Through this review article, we want to drag the attention of the researchers working in this field towards the challenges and hurdles of practical applicability IN delivery of anti-AD drugs. Moreover, the attention towards the clinical studies will ease the approval process for the administration of anti-Alzheimer drugs via IN route. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Cord plasma insulin and in utero exposure to ambient air pollution.

    PubMed

    Madhloum, Narjes; Janssen, Bram G; Martens, Dries S; Saenen, Nelly D; Bijnens, Esmée; Gyselaers, Wilfried; Penders, Joris; Vanpoucke, Charlotte; Lefebvre, Wouter; Plusquin, Michelle; Nawrot, Tim S

    2017-08-01

    Cardio-metabolic risk factors including insulin levels are at young age barely perceived as harmful, but over time these risk factors may track and lead to higher risk of metabolic syndrome. Studies showed that exposure to air pollution is associated with an increased risk of insulin resistance in childhood. We determined whether the origin of type 2 diabetes can be found in the early childhood by examining the levels of insulin in the neonatal cord blood and whether this can be considered as a disease marker for later life. In the ENVIRONAGE (ENVIRonmental influence ON early AGEing) birth cohort, we recruited 620 mother-infant pairs between February 2nd 2010 until August 12th 2014 at the East-Limburg Hospital in Genk, Belgium. We investigated in 590 newborns the association between cord plasma insulin levels and exposure to particulate matter (PM 2.5 and PM 10 ) and nitrogen dioxide (NO 2 ) in various exposure windows during pregnancy. Trimester-specific air pollutant exposure levels were estimated for each mother's home address using a spatiotemporal model. Cord plasma insulin levels averaged 33.1pmol/L (25-75th percentile: 20.1-53.5), while PM 2.5 exposure during pregnancy averaged (SD) 13.7μg/m 3 (2.4). Independent of maternal age, newborn's sex, birth weight, gestational age, parity, early-pregnancy BMI, ethnicity, smoking status, time of the day, maternal education, time of delivery, and season of delivery, cord plasma insulin levels increased with 15.8% (95% CI 7.8 to 24.4, p<0.0001) for each SD increment in PM 2.5 levels during the entire pregnancy and was most pronounced in the 2nd trimester (13.1%, 95% CI 3.4 to 23.7, p=0.007) of pregnancy. The results for PM 10 exposure were similar with those of PM 2.5 exposure but we did not observe an association between cord blood insulin levels and NO 2 exposure. Exposure to particulate air pollution during pregnancy is associated with increased levels of cord plasma insulin at birth. The public health relevance of this association is demonstrated by the fact that a 2.4μg/m 3 (SD) increase in PM 2.5 during pregnancy on cord plasma insulin levels corresponds to the effect-size of a 9kg/m 2 higher early-pregnancy BMI on cord plasma. Particulate air pollution induced changes in cord plasma insulin levels during early life and might be a risk factor in the development of metabolic disease, such as glucose intolerance or type 2 diabetes, later in life. Copyright © 2017. Published by Elsevier Ltd.

  13. Evaluation of the timing and coordination of prandial insulin administration in the hospital.

    PubMed

    Alwan, Dhuha; Chipps, Esther; Yen, Po-Yin; Dungan, Kathleen

    2017-09-01

    The objective of this study was to examine the relationship between measures of coordinated insulin delivery and capillary blood glucose (CBG) levels among hospitalized patients and to assess nurse perceptions of insulin administration. Hospitalized patients (n=451) receiving rapid acting insulin analog (RAIA) using carbohydrate counting were retrospectively analyzed. Nurses (n=35) were asked to complete an 18-item anonymous survey assessing perception of RAIA dosing. The median time from breakfast CBG to RAIA dose was 93 (IQR 57-138) min. There was no association between timeliness measures and mean CBG at lunch or dinner. Hypoglycemia was rare (N=2). More than half (54%) of nurses were confident all of the time in determining the correct dose of RAIA, though none were confident in administering it on time. The majority of nurses perceived an electronic dosing calculator and a patient reminder to notify the nurse at the end of the meal favorably. The data demonstrate suboptimal coordination of CBG monitoring and insulin doses using a flexible meal insulin dosing strategy, though there was minimal impact on glycemic control. Nurses reported high confidence in the ability to calculate the correct insulin dose but not in the ability to administer it on time. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Insulin Glulisine in Pregnancy - Experience from Clinical Trials and Post-marketing Surveillance.

    PubMed

    Doder, Zoran; Vanechanos, Demi; Oster, Manfred; Landgraf, Wolfgang; Lin, Stephen

    2015-04-01

    Pregnancies complicated by gestational diabetes or pre-existing type 1 or type 2 diabetes mellitus are associated with a higher rate of adverse outcomes compared with pregnancies in the background population. These outcomes include miscarriage, pre-term delivery, pre-eclampsia, perinatal mortality and congenital malformations. Insulin glulisine (Apidra ® , Sanofi) is a rapid-acting insulin analogue indicated for the treatment of adults, adolescents and children 6 years or older with diabetes mellitus where treatment with insulin is required. Here, all post-marketing and clinical trials safety data with insulin glulisine in pregnancy available to Sanofi up to June 2014 are summarised together with the findings of a comprehensive literature search. Cumulatively, a total of 303 pregnancy exposures to insulin glulisine were received. Of these 303 pregnancy exposures, there were 116 live births, 12 spontaneous abortions, two late foetal intra-uterine deaths (>28 weeks), three elective abortions and 170 cases without a known pregnancy outcome. There were six cases of congenital malformations; of these, there were five live births; in the other case a live birth was not confirmed. The congenital malformations reported to date do not reveal a pattern of defects. In conclusion, the evidence to date does not suggest a causal association between insulin glulisine and an increased risk of pregnancy complications or congenital malformations.

  15. The Effects of Peripheral and Central High Insulin on Brain Insulin Signaling and Amyloid-β in Young and Old APP/PS1 Mice

    PubMed Central

    Stanley, Molly; Macauley, Shannon L.; Caesar, Emily E.; Koscal, Lauren J.; Moritz, Will; Robinson, Grace O.; Roh, Joseph; Keyser, Jennifer; Jiang, Hong

    2016-01-01

    Hyperinsulinemia is a risk factor for late-onset Alzheimer's disease (AD). In vitro experiments describe potential connections between insulin, insulin signaling, and amyloid-β (Aβ), but in vivo experiments are needed to validate these relationships under physiological conditions. First, we performed hyperinsulinemic-euglycemic clamps with concurrent hippocampal microdialysis in young, awake, behaving APPswe/PS1dE9 transgenic mice. Both a postprandial and supraphysiological insulin clamp significantly increased interstitial fluid (ISF) and plasma Aβ compared with controls. We could detect no increase in brain, ISF, or CSF insulin or brain insulin signaling in response to peripheral hyperinsulinemia, despite detecting increased signaling in the muscle. Next, we delivered insulin directly into the hippocampus of young APP/PS1 mice via reverse microdialysis. Brain tissue insulin and insulin signaling was dose-dependently increased, but ISF Aβ was unchanged by central insulin administration. Finally, to determine whether peripheral and central high insulin has differential effects in the presence of significant amyloid pathology, we repeated these experiments in older APP/PS1 mice with significant amyloid plaque burden. Postprandial insulin clamps increased ISF and plasma Aβ, whereas direct delivery of insulin to the hippocampus significantly increased tissue insulin and insulin signaling, with no effect on Aβ in old mice. These results suggest that the brain is still responsive to insulin in the presence of amyloid pathology but increased insulin signaling does not acutely modulate Aβ in vivo before or after the onset of amyloid pathology. Peripheral hyperinsulinemia modestly increases ISF and plasma Aβ in young and old mice, independent of neuronal insulin signaling. SIGNIFICANCE STATEMENT The transportation of insulin from blood to brain is a saturable process relevant to understanding the link between hyperinsulinemia and AD. In vitro experiments have found direct connections between high insulin and extracellular Aβ, but these mechanisms presume that peripheral high insulin elevates brain insulin significantly. We found that physiological hyperinsulinemia in awake, behaving mice does not increase CNS insulin to an appreciable level yet modestly increases extracellular Aβ. We also found that the brain of aged APP/PS1 mice was not insulin resistant, contrary to the current state of the literature. These results further elucidate the relationship between insulin, the brain, and AD and its conflicting roles as both a risk factor and potential treatment. PMID:27852778

  16. Fetal adaptations in insulin secretion result from high catecholamines during placental insufficiency.

    PubMed

    Limesand, Sean W; Rozance, Paul J

    2017-08-01

    Placental insufficiency and intrauterine growth restriction (IUGR) of the fetus affects approximately 8% of all pregnancies and is associated with short- and long-term disturbances in metabolism. In pregnant sheep, experimental models with a small, defective placenta that restricts delivery of nutrients and oxygen to the fetus result in IUGR. Low blood oxygen concentrations increase fetal plasma catecholamine concentrations, which lower fetal insulin concentrations. All of these observations in sheep models with placental insufficiency are consistent with cases of human IUGR. We propose that sustained high catecholamine concentrations observed in the IUGR fetus produce developmental adaptations in pancreatic β-cells that impair fetal insulin secretion. Experimental evidence supporting this hypothesis shows that chronic elevation in circulating catecholamines in IUGR fetuses persistently inhibits insulin concentrations and secretion. Elevated catecholamines also allow for maintenance of a normal fetal basal metabolic rate despite low fetal insulin and glucose concentrations while suppressing fetal growth. Importantly, a compensatory augmentation in insulin secretion occurs following inhibition or cessation of catecholamine signalling in IUGR fetuses. This finding has been replicated in normally grown sheep fetuses following a 7-day noradrenaline (norepinephrine) infusion. Together, these programmed effects will potentially create an imbalance between insulin secretion and insulin-stimulated glucose utilization in the neonate which probably explains the transient hyperinsulinism and hypoglycaemia in some IUGR infants. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.

  17. Macromolecular Colloids of Diblock Poly(amino acids) That Bind Insulin.

    PubMed

    Constancis; Meyrueix; Bryson; Huille; Grosselin; Gulik-Krzywicki; Soula

    1999-09-15

    The diblock polymer poly(l-leucine-block-l-glutamate), bLE, was synthesized by acid hydrolysis of the ester poly(l-leucine-block-l-methyl glutamate). During the hydrolysis reaction the leucine block precipitates from the reaction mixture, forming nanosized particulate structures. These particles can be purified and further suspended in water or in 0.15 M phosphate saline buffer (PBS) to give stable, colloidal dispersions. TEM analysis shows the predominant particle form to be that of platelets with a diameter of 200 nm. Smaller cylindrical or spherical particles form a relatively minor fraction of the sample. After fractionation, analysis shows the platelets to be compositionally rich in leucine, while the spheres are glutamate-rich. (1)H NMR, CD, and X-ray diffraction indicate that the core of the platelets is composed of crystalline, helical leucine segments. The poly(l-glutamate) polyelectrolyte brush extending out from the two faces of the disk stabilizes individual particles from flocculation. At pH 7.4, the nanoparticles (platelets and cylinders) spontaneously adsorb proteins, such as insulin, directly from solution. Partial desorption of the protein in its native configuration can be induced by simple dilution. The reversibility of the insulin-nanoparticle complex is the basis for a potential new delivery system. Copyright 1999 Academic Press.

  18. Adherence challenges in the management of type 1 diabetes in adolescents: prevention and intervention

    PubMed Central

    Borus, Joshua S.; Laffel, Lori

    2011-01-01

    Purpose of review Despite the availability of effective therapies, adolescents with type 1 diabetes demonstrate poorer adherence to treatment regimens compared with other pediatric age groups. Nonadherence is tightly linked to suboptimal glycemic control, increasing morbidity, and risk for premature mortality. This article will review barriers to adherence and discuss interventions that have shown promise in improving outcomes for this population. Recent findings Adolescents face numerous obstacles to adherence, including developmental behaviors, flux in family dynamics, and perceived social pressures, which compound the relative insulin resistance brought on by pubertal physiology. Some successful interventions have relied on encouraging nonjudgmental family support in the daily tasks of blood glucose monitoring and insulin administration. Other interventions overcome these barriers through the use of motivational interviewing and problem-solving techniques, flexibility in dietary recommendations, and extending provider outreach and support with technology. Summary Effective interventions build on teens' internal and external supports (family, technology, and internal motivation) in order to simplify their management of diabetes and provide opportunities for the teens to share the burdens of care. Although such strategies help to minimize the demands placed upon teens with diabetes, suboptimal glycemic control will likely persist for the majority of adolescents until technological breakthroughs allow for automated insulin delivery in closed loop systems. PMID:20489639

  19. Downregulation of Adipose Tissue Fatty Acid Trafficking in Obesity

    PubMed Central

    McQuaid, Siobhán E.; Hodson, Leanne; Neville, Matthew J.; Dennis, A. Louise; Cheeseman, Jane; Humphreys, Sandy M.; Ruge, Toralph; Gilbert, Marjorie; Fielding, Barbara A.; Frayn, Keith N.; Karpe, Fredrik

    2011-01-01

    OBJECTIVE Lipotoxicity and ectopic fat deposition reduce insulin signaling. It is not clear whether excess fat deposition in nonadipose tissue arises from excessive fatty acid delivery from adipose tissue or from impaired adipose tissue storage of ingested fat. RESEARCH DESIGN AND METHODS To investigate this we used a whole-body integrative physiological approach with multiple and simultaneous stable-isotope fatty acid tracers to assess delivery and transport of endogenous and exogenous fatty acid in adipose tissue over a diurnal cycle in lean (n = 9) and abdominally obese men (n = 10). RESULTS Abdominally obese men had substantially (2.5-fold) greater adipose tissue mass than lean control subjects, but the rates of delivery of nonesterified fatty acids (NEFA) were downregulated, resulting in normal systemic NEFA concentrations over a 24-h period. However, adipose tissue fat storage after meals was substantially depressed in the obese men. This was especially so for chylomicron-derived fatty acids, representing the direct storage pathway for dietary fat. Adipose tissue from the obese men showed a transcriptional signature consistent with this impaired fat storage function. CONCLUSIONS Enlargement of adipose tissue mass leads to an appropriate downregulation of systemic NEFA delivery with maintained plasma NEFA concentrations. However the implicit reduction in adipose tissue fatty acid uptake goes beyond this and shows a maladaptive response with a severely impaired pathway for direct dietary fat storage. This adipose tissue response to obesity may provide the pathophysiological basis for ectopic fat deposition and lipotoxicity. PMID:20943748

  20. Thiomers: potential excipients for non-invasive peptide delivery systems.

    PubMed

    Bernkop-Schnürch, Andreas; Krauland, Alexander H; Leitner, Verena M; Palmberger, Thomas

    2004-09-01

    In recent years thiolated polymers or so-called thiomers have appeared as a promising alternative in the arena of non-invasive peptide delivery. Thiomers are generated by the immobilisation of thiol-bearing ligands to mucoadhesive polymeric excipients. By formation of disulfide bonds with mucus glycoproteins, the mucoadhesive properties of these polymers are improved up to 130-fold. Due to formation of inter- and intramolecular disulfide bonds within the thiomer itself, dosage forms such as tablets or microparticles display strong cohesive properties resulting in comparatively higher stability, prolonged disintegration times and a more controlled release of the embedded peptide drug. The permeation of peptide drugs through mucosa can be improved by the use of thiolated polymers. Additionally some thiomers exhibit improved inhibitory properties towards peptidases. The efficacy of thiomers in non-invasive peptide delivery could be demonstrated by various in vivo studies. Tablets comprising a thiomer and pegylated insulin, for instance, resulted in a pharmacological efficacy of 7% after oral application to diabetic mice. Furthermore, a pharmacological efficacy of 1.3% was achieved in rats by oral administration of calcitonin tablets comprising a thiomer. Human growth hormone in a thiomer-gel was applied nasally to rats and led to a bioavailability of 2.75%. In all these studies, formulations comprising the corresponding unmodified polymer had only a marginal or no effect. According to these results drug carrier systems based on thiomers seem to be a promising tool for non-invasive peptide drug delivery.

  1. Comparison of prandial AIR inhaled insulin alone to intensified insulin glargine alone and to AIR insulin plus intensified insulin glargine in patients with type 2 diabetes previously treated with once-daily insulin glargine.

    PubMed

    Rosenstock, Julio; Eliaschewitz, Freddy G; Heilmann, Cory R; Muchmore, Douglas B; Hayes, Risa P; Belin, Ruth M

    2009-09-01

    Patients with type 2 diabetes often initiate insulin with once-daily basal insulin. Over time, many patients intensify their insulin regimens in an attempt to attain and sustain glycemic targets. This study compares three intensification approaches: changing insulin glargine to preprandial AIR inhaled insulin (developed by Alkermes, Inc. [Cambridge, MA] and Eli Lilly and Company [Indianapolis, IN]; AIR is a registered trademark of Alkermes, Inc.), intensifying glargine via validated titration algorithms (IG), or adding AIR insulin while intensifying glargine (AIR + IG). Five hundred sixty patients with hemoglobin A(1c) (A1C) of 7.5-10.5%, on one or more antihyperglycemic medications, and on once-daily insulin glargine for > or =4 months were randomly allocated to one of the three treatments lasting 52 weeks. The primary objective assessed between-group differences in A1C mean change from baseline to 24 weeks using last-observation-carried-forward (LOCF) in the intent-to-treat population. At 24 weeks, A1C was reduced from a mean baseline of 8.5% to 7.7%, 7.9%, and 7.5% for the AIR, IG, and AIR + IG groups, respectively. AIR produced 0.20% greater A1C decrease than IG (least-squares mean difference = -0.20%; 95% confidence interval [CI], -0.39, -0.02). AIR + IG had a 0.35% greater A1C decrease versus IG (95% CI, -0.57, -0.13). The -0.15% difference between AIR + IG versus AIR was not significant (P < 0.198). More hypoglycemia categorized as severe occurred with AIR alone versus IG alone at LOCF end points. More nocturnal hypoglycemia occurred with IG alone versus AIR alone and AIR + IG. Preprandial inhaled insulin provides an alternative for patients not optimized on insulin glargine alone. Glycemic control, hypoglycemic risk, delivery preference, and regimen complexity must be considered when selecting insulin initiation and optimization regimens.

  2. Developmental programming of aging of isolated pancreatic islet glucose-stimulated insulin secretion in female offspring of mothers fed low-protein diets in pregnancy and/or lactation.

    PubMed

    Morimoto, S; Sosa, T C; Calzada, L; Reyes-Castro, L A; Díaz-Díaz, E; Morales, A; Nathanielsz, P W; Zambrano, E

    2012-12-01

    Diabetes predisposition is determined by pancreatic islet insulin secretion and insulin resistance. We studied female rat offspring exposed to low-protein maternal diet (50% control protein diet) in pregnancy and/or lactation at postnatal days 36, 110 and 450. Rats were fed either control 20% casein diet (C) or restricted diet (R - 10% casein) during pregnancy. After delivery, mothers received either C or R diet until weaning to provide four offspring groups: CC, RR, CR and RC (first letter denoting maternal pregnancy diet and the second lactation diet). Serum glucose, insulin and homeostatic model assessment (HOMA) were measured. Pancreatic islets were isolated and in vitro insulin secretion quantified in low glucose (5 mM) and high glucose (11 mM). Serum glucose, insulin and HOMA were similar in all groups at 36 and 110 postnatal days. HOMA was only higher in RR at 450 postnatal days. Only CC demonstrated differences in glucose sensitivity of β-cells to high and low doses at the three ages studied. At 36 days, RR, CR and RC and at 450 days RR and RC groups did not show glucose-stimulated insulin secretion differences between low and high glucose. Aging-associated glucose-stimulated insulin secretion loss was affected by maternal dietary history, indicating that developmental programming must be considered a major factor in aging-related development of predisposition to later-life dysfunctional insulin metabolism. Female offspring islets' insulin secretion was higher than previously reported in males.

  3. Severe Hypoglycemia Requiring Medical Intervention in a Large Cohort of Adults With Diabetes Receiving Care in U.S. Integrated Health Care Delivery Systems: 2005-2011.

    PubMed

    Pathak, Ram D; Schroeder, Emily B; Seaquist, Elizabeth R; Zeng, Chan; Lafata, Jennifer Elston; Thomas, Abraham; Desai, Jay; Waitzfelder, Beth; Nichols, Gregory A; Lawrence, Jean M; Karter, Andrew J; Steiner, John F; Segal, Jodi; O'Connor, Patrick J

    2016-03-01

    Appropriate glycemic control is fundamental to diabetes care, but aggressive glucose targets and intensive therapy may unintentionally increase episodes of hypoglycemia. We quantified the burden of severe hypoglycemia requiring medical intervention in a well-defined population of insured individuals with diabetes receiving care in integrated health care delivery systems across the U.S. This observational cohort study included 917,440 adults with diabetes receiving care during 2005 to 2011 at participating SUrveillance, PREvention, and ManagEment of Diabetes Mellitus (SUPREME-DM) network sites. Severe hypoglycemia rates were based on any occurrence of hypoglycemia-related ICD-9 codes from emergency department or inpatient medical encounters and reported overall and by age, sex, comorbidity status, antecedent A1C level, and medication use. Annual rates of severe hypoglycemia ranged from 1.4 to 1.6 events per 100 person-years. Rates of severe hypoglycemia were higher among those with older age, chronic kidney disease, congestive heart failure, cardiovascular disease, depression, and higher A1C levels, and in users of insulin, insulin secretagogues, or β-blockers (P < 0.001 for all). Changes in severe hypoglycemia occurrence over time were not clinically significant in the cohort as a whole but were observed in subgroups of individuals with chronic kidney disease, congestive heart failure, and cardiovascular disease. Risk of severe hypoglycemia in clinical settings is considerably higher in identifiable patient subgroups than in randomized controlled trials. Strategies that reduce the risk of hypoglycemia in high-risk patients are needed. © 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  4. Control of brain development and homeostasis by local and systemic insulin signalling.

    PubMed

    Liu, J; Spéder, P; Brand, A H

    2014-09-01

    Insulin and insulin-like growth factors (IGFs) are important regulators of growth and metabolism. In both vertebrates and invertebrates, insulin/IGFs are made available to various organs, including the brain, through two routes: the circulating systemic insulin/IGFs act on distant organs via endocrine signalling, whereas insulin/IGF ligands released by local tissues act in a paracrine or autocrine fashion. Although the mechanisms governing the secretion and action of systemic insulin/IGF have been the focus of extensive investigation, the significance of locally derived insulin/IGF has only more recently come to the fore. Local insulin/IGF signalling is particularly important for the development and homeostasis of the central nervous system, which is insulated from the systemic environment by the blood-brain barrier. Local insulin/IGF signalling from glial cells, the blood-brain barrier and the cerebrospinal fluid has emerged as a potent regulator of neurogenesis. This review will address the main sources of local insulin/IGF and how they affect neurogenesis during development. In addition, we describe how local insulin/IGF signalling couples neural stem cell proliferation with systemic energy state in Drosophila and in mammals. © 2014 John Wiley & Sons Ltd.

  5. Diabetes: Models, Signals, and Control

    PubMed Central

    Cobelli, Claudio; Man, Chiara Dalla; Sparacino, Giovanni; Magni, Lalo; De Nicolao, Giuseppe; Kovatchev, Boris P.

    2010-01-01

    The control of diabetes is an interdisciplinary endeavor, which includes a significant biomedical engineering component, with traditions of success beginning in the early 1960s. It began with modeling of the insulin-glucose system, and progressed to large-scale in silico experiments, and automated closed-loop control (artificial pancreas). Here, we follow these engineering efforts through the last, almost 50 years. We begin with the now classic minimal modeling approach and discuss a number of subsequent models, which have recently resulted in the first in silico simulation model accepted as substitute to animal trials in the quest for optimal diabetes control. We then review metabolic monitoring, with a particular emphasis on the new continuous glucose sensors, on the analyses of their time-series signals, and on the opportunities that they present for automation of diabetes control. Finally, we review control strategies that have been successfully employed in vivo or in silico, presenting a promise for the development of a future artificial pancreas and, in particular, discuss a modular architecture for building closed-loop control systems, including insulin delivery and patient safety supervision layers. We conclude with a brief discussion of the unique interactions between human physiology, behavioral events, engineering modeling and control relevant to diabetes. PMID:20936056

  6. Diabetes in Kyrgyzstan: changes between 2002 and 2009.

    PubMed

    Beran, David; Abdraimova, Aida; Akkazieva, Baktygul; McKee, Martin; Balabanova, Dina; Yudkin, John S

    2013-01-01

    Health system reform in Kyrgyzstan is seen as a relative success story in central Asia. Initially, most attention focused on structural changes, and it is only since 2006 that the delivery of care and the experience of health service users have risen on the agenda. One exception from the earlier period was a rapid appraisal of the management of diabetes, undertaken in 2002. Using that study as a baseline, we describe the findings of a new evaluation of diabetes management, undertaken in 2009, using the Rapid Assessment Protocol for Insulin Access, now implemented in seven countries. Access to care has improved through the creation of the Family Medical Centres and the deployment of endocrinologists to them. Another improvement is the access to insulin and related medicines, although assessment of the procurement system reveals that the government is getting very poor value for money. Looking ahead, there are grounds for optimism that the passage of the law on diabetes may progressively have a greater impact. Although the law is not yet fully implemented, it has enabled the diabetes associations to defend the rights of their members. This increased capacity is credited with some improvements in diabetes care. Copyright © 2012 John Wiley & Sons, Ltd.

  7. Low molecular weight protamine (LMWP): a nontoxic protamine substitute and an effective cell-penetrating peptide.

    PubMed

    He, Huining; Ye, Junxiao; Liu, Ergang; Liang, Qiuling; Liu, Quan; Yang, Victor C

    2014-11-10

    Low molecular weight protamine (LMWP) is a peptide fragment produced in our laboratory from enzymatic digestion of native protamine. More than 30 papers studying the properties and applications of LMWP have been published by our group in various journals since its initial discovery in 1999. Results have shown that LMWP could completely neutralize the anticoagulant functions of both heparin and low molecular weight heparin (LMWH), with reduced antigenicity and cross-reactivity toward the mice-derived anti-protamine antibodies. Aside from its potential as a heparin/LMWH antagonist, LMWP also shows the ability to retard insulin adsorption by the formation of an insoluble complex, making it a less toxic long-lasting insulin product than the conventional neutral protamine Hagedorn (NPH) insulin for diabetic control. Importantly, LMWP (Sequence: VSRRRRRRGGRRRR), with 10 arginine residues in its structure, could function as a cell-penetrating peptide (CPP), also termed protein transduction domain (PTD), to achieve effective intracellular protein or gene delivery in clinical practice. In this paper, we present a thorough review of our work related to LMWP, with the aim of providing readers an insight into its potential to be a clinical protamine substitute as well as a non-toxic cell penetrating peptide applicable to achieve intracellular protein and gene delivery. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Continuous corticosterone delivery via the drinking water or pellet implantation: A comparative study in mice.

    PubMed

    Gasparini, Sylvia J; Weber, Marie-Christin; Henneicke, Holger; Kim, Sarah; Zhou, Hong; Seibel, Markus J

    2016-12-01

    In order to investigate the effects of glucocorticoid excess in rodent models, reliable methods of continuous glucocorticoid delivery are essential. The current study compares two methods of corticosterone (CS) delivery in regards to their ability to induce typical adverse outcomes such as fat accrual, insulin resistance, sarcopenia and bone loss. Eight-week-old mice received CS for 4weeks either via the drinking water (25-100μgCS/mL) or through weekly surgical implantation of slow release pellets containing 1.5mg CS. Both methods induced abnormal fat mass accrual, inhibited lean mass accretion and bone expansion, suppressed serum osteocalcin levels and induced severe insulin resistance. There was a clear dose dependant relationship between the CS concentrations in the drinking water and the severity of the phenotype, with a concentration of 50μg CS/mL drinking water most closely matching the metabolic changes induced by weekly pellet implantations. In contrast to pellets, however, delivery of CS via the drinking water resulted in a consistent diurnal exposure pattern, closely mimicking the kinetics of clinical glucocorticoid therapy. In addition, the method is safe, inexpensive, easily adjustable, non-invasive and avoids operative stress to the animals. Our data demonstrate that delivery of CS via the drinking water has advantages over weekly implantations of slow-release pellets. A dose of 50μg CS/mL drinking water is appropriate for the investigation of chronic glucocorticoid excess in mice. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  9. Mechanisms of insulin action on sympathetic nerve activity

    NASA Technical Reports Server (NTRS)

    Muntzel, Martin S.; Anderson, Erling A.; Johnson, Alan Kim; Mark, Allyn L.

    1996-01-01

    Insulin resistance and hyperinsulinemia may contribute to the development of arterial hypertension. Although insulin may elevate arterial pressure, in part, through activation of the sympathetic nervous system, the sites and mechanisms of insulin-induced sympathetic excitation remain uncertain. While sympathoexcitation during insulin may be mediated by the baroreflex, or by modulation of norepinephrine release from sympathetic nerve endings, it has been shown repeatedly that insulin increases sympathetic outflow by actions on the central nervous system. Previous studies employing norepinephrine turnover have suggested that insulin causes sympathoexcitation by acting in the hypothalamus. Recent experiments from our laboratory involving direct measurements of regional sympathetic nerve activity have provided further evidence that insulin acts in the central nervous system. For example, administration of insulin into the third cerebralventricle increased lumbar but not renal or adrenal sympathetic nerve activity in normotensive rats. Interestingly, this pattern of regional sympathetic nerve responses to central neural administration of insulin is similar to that seen with systemic administration of insulin. Further, lesions of the anteroventral third ventricle hypothalamic (AV3V) region abolished increases in sympathetic activity to systemic administration of insulin with euglycemic clamp, suggesting that AV3V-related structures are critical for insulin-induced elevations in sympathetic outflow.

  10. Parity Increases Insulin Requirements in Pregnant Women With Type 1 Diabetes.

    PubMed

    Skajaa, Gitte Ø; Fuglsang, Jens; Kampmann, Ulla; Ovesen, Per G

    2018-06-01

    Tight glycemic control throughout pregnancy in women with type 1 diabetes is crucial, and knowledge about which factors that affect insulin sensitivity could improve the outcome for both mother and offspring. To evaluate insulin requirements in women with type 1 diabetes during pregnancy and test whether parity affects insulin requirements. Observational cohort study consisting of women with type 1 diabetes who gave birth at Aarhus University Hospital, Denmark, from 2004 to 2014. Daily insulin requirement (the hypothesis that parity could affect insulin resistance was formulated before data collection). A total of 380 women with a total of 536 pregnancies were included in the study. Mean age was 31.1 years, and prepregnancy hemoglobin A1c was 60 mmol/mol. Parity was as follows: P0, 43%; P1, 40%; P2, 14%; and P3+4, 3%. Insulin requirements from weeks 11 to 16 decreased significantly by 4% (P = 0.0004) and rose from week 19 to delivery with a peak of 70% (P < 0.0005) at weeks 33 to 36. Overall, insulin requirements increased significantly with parity. The unadjusted differences between P0 and P1, P2, and P3+4 were 9% (P < 0.0005), 12% (P < 0.0005), and 23% (P < 0.0011), respectively. After adjustment for confounders, differences were 13% (P < 0.0005), 20% (P < 0.0005), and 36% (P < 0.0005). We also observed an adjusted difference between P1 and P3+4 of 20% (P < 0.0012). The data show changes in insulin requirements from week to week in pregnancy and indicate that insulin requirements increase with parity. This suggests that the patient's parity probably should be considered in choosing insulin dosages for pregnant women with type 1 diabetes.

  11. Functional Evaluation of the Reusable JuniorSTAR® Half-Unit Insulin Pen.

    PubMed

    Klonoff, David; Nayberg, Irina; Rabbone, Ivana; Domenger, Catherine; Stauder, Udo; Oualali, Hamid; Danne, Thomas

    2015-05-01

    The functional performance of the JuniorSTAR(®) (Sanofi, Paris, France) half-unit insulin pen was evaluated through a series of specific objective tests to assess the dose accuracy, pen weight, injection force, and dialing torque. Pens (n = 60) were tested under standard atmospheric conditions with 3 different types of insulins manufactured by Sanofi (insulin glargine, insulin glulisine, and biphasic insulin isophane). The dose accuracy was tested according to the ISO 11608-1:2012 standards. Injection doses of 0.010, 0.155, and 0.300 ml were evaluated. For mean weight evaluation, the pens without the cartridge were weighed on precision balances. The injection force was measured using a texture analyzer and the dialing torque was measured using a torque meter. JuniorSTAR met the ISO 11608-1:2012 criteria for dose accuracy as all the delivered doses were within the predefined limits for all types of insulin tested. The mean weight of the JuniorSTAR pen was 33.4 g (SD = 0.075). The mean injection force was 6.0 N (SD = 0.8), 4.3 N (SD = 0.4), and 5.1 N (SD = 0.6) for insulin glargine, insulin glulisine, and biphasic insulin isophane, respectively. The mean dialing torque was 5.09 Ncm (SD = 0.29) and 5.88 Ncm (SD = 0.53) for setting and correcting a dose, respectively. Together with results from a previously reported usability survey, these results show that the JuniorSTAR reusable, half-unit pen is a lightweight and accurate device for insulin delivery with a dialing torque and injection force suitable for young people with type 1 diabetes. © 2015 Diabetes Technology Society.

  12. Functional Evaluation of the Reusable JuniorSTAR® Half-Unit Insulin Pen

    PubMed Central

    Klonoff, David; Nayberg, Irina; Rabbone, Ivana; Domenger, Catherine; Stauder, Udo; Oualali, Hamid; Danne, Thomas

    2015-01-01

    Background: The functional performance of the JuniorSTAR® (Sanofi, Paris, France) half-unit insulin pen was evaluated through a series of specific objective tests to assess the dose accuracy, pen weight, injection force, and dialing torque. Method: Pens (n = 60) were tested under standard atmospheric conditions with 3 different types of insulins manufactured by Sanofi (insulin glargine, insulin glulisine, and biphasic insulin isophane). The dose accuracy was tested according to the ISO 11608-1:2012 standards. Injection doses of 0.010, 0.155, and 0.300 ml were evaluated. For mean weight evaluation, the pens without the cartridge were weighed on precision balances. The injection force was measured using a texture analyzer and the dialing torque was measured using a torque meter. Results: JuniorSTAR met the ISO 11608-1:2012 criteria for dose accuracy as all the delivered doses were within the predefined limits for all types of insulin tested. The mean weight of the JuniorSTAR pen was 33.4 g (SD = 0.075). The mean injection force was 6.0 N (SD = 0.8), 4.3 N (SD = 0.4), and 5.1 N (SD = 0.6) for insulin glargine, insulin glulisine, and biphasic insulin isophane, respectively. The mean dialing torque was 5.09 Ncm (SD = 0.29) and 5.88 Ncm (SD = 0.53) for setting and correcting a dose, respectively. Conclusions: Together with results from a previously reported usability survey, these results show that the JuniorSTAR reusable, half-unit pen is a lightweight and accurate device for insulin delivery with a dialing torque and injection force suitable for young people with type 1 diabetes. PMID:25633967

  13. Employment rights of people with diabetes: changing technology and changing law.

    PubMed

    Griffin, John W

    2013-03-01

    Though the treatment of diabetes has advanced remarkably, the law and many employers have not always kept pace. New insulins, delivery systems, and monitoring systems give people with diabetes exceptional control over their blood sugar and virtually eliminate serious complications such as hypoglycemia and hyperglycemia. Changes in the law, particularly the Americans with Disabilities Act and its 2008 amendments, give people with diabetes greater rights and employment opportunities than ever before. Despite these advances, many employers continue to use blanket bans or ill-considered standards to bar people with diabetes. Efforts to break down these remaining barriers are ongoing through employee litigation and through the American Diabetes Association's collaboration with entities that set occupational standards. © 2013 Diabetes Technology Society.

  14. Twelve-Week 24/7 Ambulatory Artificial Pancreas With Weekly Adaptation of Insulin Delivery Settings: Effect on Hemoglobin A1c and Hypoglycemia.

    PubMed

    Dassau, Eyal; Pinsker, Jordan E; Kudva, Yogish C; Brown, Sue A; Gondhalekar, Ravi; Dalla Man, Chiara; Patek, Steve; Schiavon, Michele; Dadlani, Vikash; Dasanayake, Isuru; Church, Mei Mei; Carter, Rickey E; Bevier, Wendy C; Huyett, Lauren M; Hughes, Jonathan; Anderson, Stacey; Lv, Dayu; Schertz, Elaine; Emory, Emma; McCrady-Spitzer, Shelly K; Jean, Tyler; Bradley, Paige K; Hinshaw, Ling; Laguna Sanz, Alejandro J; Basu, Ananda; Kovatchev, Boris; Cobelli, Claudio; Doyle, Francis J

    2017-12-01

    Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A 1c (HbA 1c ). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. Twenty-nine patients completed the trial. HbA 1c , 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (-0.3, 95% CI -0.5 to -0.2, P < 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (-3.1, 95% CI -4.1 to -2.1, P < 0.001) and overnight from 4.1 to 1.1% (-3.1, 95% CI -4.2 to -1.9, P < 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. Use of our novel adaptive AP yielded significant reductions in HbA 1c and hypoglycemia. © 2017 by the American Diabetes Association.

  15. Recombinant DNA derived monomeric insulin analogue: comparison with soluble human insulin in normal subjects.

    PubMed

    Vora, J P; Owens, D R; Dolben, J; Atiea, J A; Dean, J D; Kang, S; Burch, A; Brange, J

    1988-11-12

    To compare the rate of absorption from subcutaneous tissue and the resulting hypoglycaemic effect of iodine-125 labelled soluble human insulin and a monomeric insulin analogue derived by recombinant DNA technology. Single blind randomised comparison of equimolar doses of 125I labelled soluble human insulin and insulin analogue. Study in normal people at a diabetes research unit and a university department of medical physics. Seven healthy male volunteers aged 20-39 not receiving any other drugs. After an overnight fast and a basal period of one hour two doses (0.05 and 0.1 U/kg) of 125I labelled soluble human insulin and insulin analogue were injected subcutaneously into the anterior abdominal wall on four separate days. To find a fast acting insulin for meal related requirements in insulin dependent diabetics. MEASUREMENTS and main results--Residual radioactivity at the injection site was measured continuously for the first two hours after injection of the 125I labelled preparations and thereafter for five minutes simultaneously with blood sampling. Frequent venous blood samples were obtained over six hours for determination of plasma immunoreactive insulin, insulin analogue, glucose, and glucagon values. Time to 50% of initial radioactivity at the injection site for the insulin analogue compared with soluble insulin was 61 v 135 minutes (p less than 0.05) with 0.05 U/kg and 67 v 145 minutes (p less than 0.001) with 0.1 U/kg. Concentrations in plasma increased faster after the insulin analogue compared with soluble insulin, resulting in higher plasma concentrations between 10 and 150 minutes (0.001 less than p less than 0.05) after 0.05 U/kg and between 40 and 360 minutes (0.001 less than p less than 0.05) after 0.1 U/kg. The hypoglycaemic response to insulin analogue was a plasma glucose nadir at 60 minutes with both doses compared with 90 and 120 minutes with soluble insulin at 0.5 and 0.1 U/kg respectively. The response of glucagon substantiated the earlier and more dramatic hypoglycaemic effect with the insulin analogue. The much faster absorption from subcutaneous tissue of the disubstituted monomeric insulin analogue compared with soluble insulin suggests that the analogue may be a potential candidate for rapid insulin delivery after subcutaneous bolus injection.

  16. Recombinant DNA derived monomeric insulin analogue: comparison with soluble human insulin in normal subjects.

    PubMed Central

    Vora, J. P.; Owens, D. R.; Dolben, J.; Atiea, J. A.; Dean, J. D.; Kang, S.; Burch, A.; Brange, J.

    1988-01-01

    OBJECTIVE--To compare the rate of absorption from subcutaneous tissue and the resulting hypoglycaemic effect of iodine-125 labelled soluble human insulin and a monomeric insulin analogue derived by recombinant DNA technology. DESIGN--Single blind randomised comparison of equimolar doses of 125I labelled soluble human insulin and insulin analogue. SETTING--Study in normal people at a diabetes research unit and a university department of medical physics. SUBJECTS--Seven healthy male volunteers aged 20-39 not receiving any other drugs. INTERVENTIONS--After an overnight fast and a basal period of one hour two doses (0.05 and 0.1 U/kg) of 125I labelled soluble human insulin and insulin analogue were injected subcutaneously into the anterior abdominal wall on four separate days. END POINT--To find a fast acting insulin for meal related requirements in insulin dependent diabetics. MEASUREMENTS and main results--Residual radioactivity at the injection site was measured continuously for the first two hours after injection of the 125I labelled preparations and thereafter for five minutes simultaneously with blood sampling. Frequent venous blood samples were obtained over six hours for determination of plasma immunoreactive insulin, insulin analogue, glucose, and glucagon values. Time to 50% of initial radioactivity at the injection site for the insulin analogue compared with soluble insulin was 61 v 135 minutes (p less than 0.05) with 0.05 U/kg and 67 v 145 minutes (p less than 0.001) with 0.1 U/kg. Concentrations in plasma increased faster after the insulin analogue compared with soluble insulin, resulting in higher plasma concentrations between 10 and 150 minutes (0.001 less than p less than 0.05) after 0.05 U/kg and between 40 and 360 minutes (0.001 less than p less than 0.05) after 0.1 U/kg. The hypoglycaemic response to insulin analogue was a plasma glucose nadir at 60 minutes with both doses compared with 90 and 120 minutes with soluble insulin at 0.5 and 0.1 U/kg respectively. The response of glucagon substantiated the earlier and more dramatic hypoglycaemic effect with the insulin analogue. CONCLUSIONS--The much faster absorption from subcutaneous tissue of the disubstituted monomeric insulin analogue compared with soluble insulin suggests that the analogue may be a potential candidate for rapid insulin delivery after subcutaneous bolus injection. PMID:3145064

  17. Maize arabinoxylan gels as protein delivery matrices.

    PubMed

    Berlanga-Reyes, Claudia M; Carvajal-Millán, Elizabeth; Lizardi-Mendoza, Jaime; Rascón-Chu, Agustin; Marquez-Escalante, Jorge A; Martínez-López, Ana Luisa

    2009-04-08

    The laccase induced gelation of maize bran arabinoxylans at 2.5% (w/v) in the presence of insulin or beta-lactoglobulin at 0.1% (w/v) was investigated. Insulin and beta-lacto-globulin did not modify either the gel elasticity (9 Pa) or the cross-links content (0.03 and 0.015 microg di- and triferulic acids/mg arabinoxylan, respectively). The protein release capability of the gel was also investigated. The rate of protein release from gels was dependent on the protein molecular weight. The apparent diffusion coefficient was 0.99 x 10(-7) and 0.79 x 10(-7) cm(2)/s for insulin (5 kDa) and beta-lactoglobulin (18 kDa), respectively. The results suggest that maize bran arabinoxylan gels can be potential candidates for the controlled release of proteins.

  18. Pectin-cysteine conjugate: synthesis and in-vitro evaluation of its potential for drug delivery.

    PubMed

    Majzoob, Sayeh; Atyabi, Fatemeh; Dorkoosh, Farid; Kafedjiiski, Krum; Loretz, Brigitta; Bernkop-Schnürch, Andreas

    2006-12-01

    This study was aimed at improving certain properties of pectin by introduction of thiol moieties on the polymer. Thiolated pectin was synthesized by covalent attachment of cysteine. Pectin-cysteine conjugate was evaluated for its ability to be degraded by pectinolytic enzyme. The toxicity profile of the thiolated polymer in Caco-2-cells, its permeation enhancing effect and its mucoadhesive and swelling properties were studied. Moreover insulin-loaded hydrogel beads of the new polymer were examined for their stability in simulated gastrointestinal conditions and their drug release profile. The new polymer displayed 892.27 +/- 68.68 micromol thiol groups immobilized per g polymer, and proved to have retained its biodegradability, upon addition of Pectinex Ultra SPL in-vitro, determined by viscosity measurements and titration method. Pectin-cysteine showed no severe toxicity in Caco-2 cells, as tested by 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide (MTT) and lactate dehydrogenase (LDH) assays. Moreover, the synthesized polymer exhibited a relative permeation enhancement ratio of 1.61 for sodium fluorescein, compared to unmodified pectin. Pectin-cysteine conjugate exhibited approximately 5-fold increased in in-vitro adhesion duration and significantly improved cohesive properties. Zinc pectin-cysteine beads showed improved stability in simulated gastrointestinal media; however, insulin release from these beads followed the same profile as unmodified zinc pectinate beads. Due to favourable safety and biodegradability profile, and improved cohesive and permeation-enhancing properties, pectin-cysteine might be a promising excipient in various transmucosal drug delivery systems.

  19. Nutrition and Hyperglycemia Management in the Inpatient Setting (Meals on Demand, Parenteral, or Enteral Nutrition).

    PubMed

    Drincic, Andjela T; Knezevich, Jon T; Akkireddy, Padmaja

    2017-08-01

    The goal of this paper is to provide the latest evidence and expert recommendations for management of hospitalized patients with diabetes or hyperglycemia receiving enteral (EN), parenteral (PN) nutrition support or, those with unrestricted oral diet, consuming meals on demand. Patients with and without diabetes mellitus commonly develop hyperglycemia while receiving EN or PN support, placing them at increased risk of adverse outcomes, including in-hospital mortality. Very little new evidence is available in the form of randomized controlled trials (RCT) to guide the glycemic management of these patients. Reduction in the dextrose concentration within parenteral nutrition as well as selection of an enteral formula that diminishes the carbohydrate exposure to a patient receiving enteral nutrition are common strategies utilized in practice. No specific insulin regimen has been shown to be superior in the management of patients receiving EN or PN nutrition support. For those receiving oral nutrition, new challenges have been introduced with the most recent practice allowing patients to eat meals on demand, leading to extreme variability in carbohydrate exposure and risk of hypo and hyperglycemia. Synchronization of nutrition delivery with the astute use of intravenous or subcutaneous insulin therapy to match the physiologic action of insulin in patients receiving nutritional support should be implemented to improve glycemic control in hospitalized patients. Further RCTs are needed to evaluate glycemic and other clinical outcomes of patients receiving nutritional support. For patients eating meals on demand, development of hospital guidelines and policies are needed, ensuring optimization and coordination of meal insulin delivery in order to facilitate patient safety.

  20. Glucose counterregulation, hypoglycemia, and intensive insulin therapy in diabetes mellitus.

    PubMed

    Cryer, P E; Gerich, J E

    1985-07-25

    The prevention or correction of hypoglycemia is the result of both dissipation of insulin and activation of counterregulatory systems. In the models studied to date, glucagon and epinephrine have been shown to be the key counterregulatory factors; the potential roles of other hormones, neural factors, or substrate mechanisms in other models and during more gradual recovery from hypoglycemia remain to be defined. Deficient glucagon responses to decrements in plasma glucose, which are common in patients with IDDM and occur in some patients with NIDDM, result in altered counterregulation. But counterregulation is generally adequate, because epinephrine compensates for it. Defective glucose counterregulation due to combined deficiencies of glucagon and epinephrine secretory responses occurs in many patients, typically those with longstanding diabetes, and must be added to the list of factors known to increase the risk of hypoglycemia, at least during intensive therapy. From the material reviewed, it should be apparent that much has been learned about glucose counterregulation. It should be equally clear that much remains to be learned. Among the many possibilities, we consider four worthy of emphasis. First of all, we need to examine the physiology and pathophysiology of glucose counterregulation in additional models (e.g., during exercise) and over longer periods. Secondly, we need to determine whether central nervous system adaptation to antecedent glycemia occurs and, if so, identify its mechanisms. Thirdly, we need to develop better methods of insulin delivery or learn to correct or compensate for defective counterregulatory systems, if we are to achieve euglycemia safely in diabetic patients with defective glucose counterregulation. Finally, we need to know whether effective control of diabetes mellitus prevents development of defective glucose counterregulation.

  1. The Portal Theory Supported by Venous Drainage–Selective Fat Transplantation

    PubMed Central

    Rytka, Julia M.; Wueest, Stephan; Schoenle, Eugen J.; Konrad, Daniel

    2011-01-01

    OBJECTIVE The “portal hypothesis” proposes that the liver is directly exposed to free fatty acids and cytokines increasingly released from visceral fat tissue into the portal vein of obese subjects, thus rendering visceral fat accumulation particularly hazardous for the development of hepatic insulin resistance and type 2 diabetes. In the present study, we used a fat transplantation paradigm to (artificially) increase intra-abdominal fat mass to test the hypothesis that venous drainage of fat tissue determines its impact on glucose homeostasis. RESEARCH DESIGN AND METHODS Epididymal fat pads of C57Bl6/J donor mice were transplanted into littermates, either to the parietal peritoneum (caval/systemic venous drainage) or, by using a novel approach, to the mesenterium, which confers portal venous drainage. RESULTS Only mice receiving the portal drained fat transplant developed impaired glucose tolerance and hepatic insulin resistance. mRNA expression of proinflammatory cytokines was increased in both portally and systemically transplanted fat pads. However, portal vein (but not systemic) plasma levels of interleukin (IL)-6 were elevated only in mice receiving a portal fat transplant. Intriguingly, mice receiving portal drained transplants from IL-6 knockout mice showed normal glucose tolerance. CONCLUSIONS These results demonstrate that the metabolic fate of intra-abdominal fat tissue transplantation is determined by the delivery of inflammatory cytokines to the liver specifically via the portal system, providing direct evidence in support of the portal hypothesis. PMID:20956499

  2. Sex and ApoE Genotype Differences in Treatment Response to Two Doses of Intranasal Insulin in Adults with Mild Cognitive Impairment or Alzheimer’s Disease

    PubMed Central

    Claxton, Amy; Baker, Laura D.; Wilkinson, Charles W.; Trittschuh, Emily H.; Chapmana, Darla; Watson, G. Stennis; Cholerton, Brenna; Plymate, Stephen R.; Arbuckle, Matthew; Craft, Suzanne

    2014-01-01

    A previous clinical trial demonstrated that four months of treatment with intranasal insulin improves cognition and function for patients with Alzheimer’s disease (AD) or mild cognitive impairment (MCI), but prior studies suggest that response to insulin treatment may differ by sex and ApoE ε4 carriage. Thus, responder analyses using repeated measures analysis of covariance were completed on the trial’s 104 participants with MCI or AD who received either placebo or 20 or 40 IU of insulin for 4 months, administered by a nasal delivery device. Results indicate that men and women with memory impairment responded differently to intranasal insulin treatment. On delayed story memory, men and women showed cognitive improvement when taking 20 IU of intranasal insulin, but only men showed cognitive improvement for the 40 IU dose. The sex difference was most apparent for ApoE ε4 negative individuals. For the 40 IU dose, ApoE ε4 negative men improved while ApoE ε4 negative women worsened. Their ApoE ε4 positive counterparts remained cognitively stable. This sex effect was not detected in functional measures. However, functional abilities were relatively preserved for women on either dose of intranasal insulin compared with men. Unlike previous studies with young adults, neither men nor women taking intranasal insulin exhibited a significant change in weight over 4 months of treatment. PMID:23507773

  3. The effect of different doses of vitamin D supplementation on insulin resistance during pregnancy.

    PubMed

    Soheilykhah, Sedigheh; Mojibian, Mahdieh; Moghadam, Maryam Jannati; Shojaoddiny-Ardekani, Ahmad

    2013-04-01

    Low serum vitamin D levels are correlated with insulin resistance during pregnancy. We have assessed the effects of different doses of vitamin D on insulin resistance during pregnancy. A randomized clinical trial was done on 120 women with a gestational age of less than 12 weeks. The women were divided into three groups randomly. Group A received 200 IU vitamin D daily, group B 50,000 IU vitamin D monthly and group C 50,000 IU vitamin D every 2 weeks from 12 weeks of pregnancy until delivery. The serum levels of fasting blood sugar (FBS), insulin, calcium and 25-hydroxyvitamin D were measured before and after intervention. We used the homeostatic model assessment of insulin resistance (HOMA-IR) as a surrogate measure of insulin resistance. The mean ± standard deviation of serum 25-hydroxyvitamin D increased in group C from 7.3 ± 5.9 to 34.1 ± 11.5 ng/ml and in group B it increased from 7.3 ± 5.3 to 27.23 ± 10.7 ng/ml, but the level of vitamin D in group A increased from 8.3 ± 7.8 to 17.7 ± 9.3 ng/ml (p < 0.001). The mean differences of insulin and HOMA-IR before and after intervention in groups A and C were significant (p = 0.01, p = 0.02). This study has shown that supplementation of pregnant women with 50 000 IU vitamin D every 2 weeks improved insulin resistance significantly.

  4. Changing roles in community health care: Delegation of insulin injections to health care support workers.

    PubMed

    Dutton, Julie; McCaskill, Kelly; Alton, Sarah; Levesley, Maria; Hemingway, Cath; Farndon, Lisa

    2018-01-02

    Diabetes is a common long-term condition affecting many people many of whom require support with their insulin injections at home. These injections are often carried out by community nurses if individuals are unable to self-manage their condition. This paper describes a pilot project where health care support workers were trained to administer insulin at home for suitable patients. Four patients took part in the pilot study and two support workers were trained to give the insulin injections. The project was evaluated well by all those who took part. It freed up 80 hours of nursing time while also providing the support workers with an extended scope of practice and associated increased in job satisfaction. No untoward medication errors were reported as a result of this initiative. This project will now be rolled out to the wider nursing teams with a staggered approach to the delivery of the training to ensure there is not a detrimental effect on patient care.

  5. Comparing twice- versus four-times daily insulin in mothers with gestational diabetes in Pakistan and its implications.

    PubMed

    Saleem, Nazish; Godman, Brian; Hussain, Shahzad

    2016-08-01

    Gestational diabetes mellitus is a common medical problem associated with maternal and fetal complications. Good glycemic control is the cornerstone of treatment. Compare outcomes between four times (q.i.d) and twice daily (b.i.d) regimens. The morning dose of the b.i.d regimen contained two-thirds of the total insulin, comprising a third human regular insulin and two-thirds human intermediate insulin; equal amounts in the evening. 480 women at >30 weeks with gestational diabetes mellitus with failure to control blood glucose were randomly assigned to either regimen. Mean time to the control of blood glucose was significantly less and glycemic control significantly increased with the q.i.d regimen. Operative deliveries, extent of neonatal hypoglycemia, babies with low Agpar scores and those with hyperbilirubinemia were significantly higher with the b.i.d daily regimen. The q.i.d daily regime was associated with improved fetal and maternal outcomes. Consequently should increasingly be used in Pakistan, assisted by lower acquisition costs.

  6. Insulin Glulisine in Pregnancy – Experience from Clinical Trials and Post-marketing Surveillance

    PubMed Central

    Vanechanos, Demi; Oster, Manfred; Landgraf, Wolfgang; Lin, Stephen

    2015-01-01

    Abstract Pregnancies complicated by gestational diabetes or pre-existing type 1 or type 2 diabetes mellitus are associated with a higher rate of adverse outcomes compared with pregnancies in the background population. These outcomes include miscarriage, pre-term delivery, pre-eclampsia, perinatal mortality and congenital malformations. Insulin glulisine (Apidra®, Sanofi) is a rapid-acting insulin analogue indicated for the treatment of adults, adolescents and children 6 years or older with diabetes mellitus where treatment with insulin is required. Here, all post-marketing and clinical trials safety data with insulin glulisine in pregnancy available to Sanofi up to June 2014 are summarised together with the findings of a comprehensive literature search. Cumulatively, a total of 303 pregnancy exposures to insulin glulisine were received. Of these 303 pregnancy exposures, there were 116 live births, 12 spontaneous abortions, two late foetal intra-uterine deaths (>28 weeks), three elective abortions and 170 cases without a known pregnancy outcome. There were six cases of congenital malformations; of these, there were five live births; in the other case a live birth was not confirmed. The congenital malformations reported to date do not reveal a pattern of defects. In conclusion, the evidence to date does not suggest a causal association between insulin glulisine and an increased risk of pregnancy complications or congenital malformations. PMID:29632561

  7. The role of exogenous insulin in the complex of hepatic lipidosis and ketosis associated with insulin resistance phenomenon in postpartum dairy cattle.

    PubMed

    Hayirli, A

    2006-10-01

    As a result of a marked decline in dry matter intake (DMI) prior to parturition and a slow rate of increase in DMI relative to milk production after parturition, dairy cattle experience a negative energy balance. Changes in nutritional and metabolic status during the periparturient period predispose dairy cattle to develop hepatic lipidosis and ketosis. The metabolic profile during early lactation includes low concentrations of serum insulin, plasma glucose, and liver glycogen and high concentrations of serum glucagon, adrenaline, growth hormone, plasma beta-hydroxybutyrate and non-esterified fatty acids, and liver triglyceride. Moreover, during late gestation and early lactation, flow of nutrients to fetus and mammary tissues are accorded a high degree of metabolic priority. This priority coincides with lowered responsiveness and sensitivity of extrahepatic tissues to insulin, which presumably plays a key role in development of hepatic lipidosis and ketosis. Hepatic lipidosis and ketosis compromise production, immune function, and fertility. Cows with hepatic lipidosis and ketosis have low tissue responsiveness to insulin owing to ketoacidosis. Insulin has numerous roles in metabolism of carbohydrates, lipids and proteins. Insulin is an anabolic hormone and acts to preserve nutrients as well as being a potent feed intake regulator. In addition to the major replacement therapy to alleviate severity of negative energy balance, administration of insulin with concomitant delivery of dextrose increases efficiency of treatment for hepatic lipidosis and ketosis. However, data on use of insulin to prevent these lipid-related metabolic disorders are limited and it should be investigated.

  8. Synthesis and characterization of a novel cationic hydrogel base on salecan-g-PMAPTAC.

    PubMed

    Wei, Wei; Qi, Xiaoliang; Li, Junjian; Zhong, Yin; Zuo, Gancheng; Pan, Xihao; Su, Ting; Zhang, Jianfa; Dong, Wei

    2017-08-01

    Salecan is a biological macromolecular and biocompatible polysaccharide that has been investigated for recent years. Herein, we report a novel cationic hydrogel fabricated by graft-polymerizing 3-(methacryloylamino)propyl-trimethylammonium chloride (MAPTAC) onto salecan chains. The obtained hydrogels were transparent, solid-elastic, macro-porous, ion-sensitive, and non-cytotoxic. The swelling ratios increased with salecan content, while mechanical strength does the opposite. Moreover, drug delivery test was studied as a potential application. Diclofenac sodium (DS) and insulin were selected as model drugs. Interestingly, in drug loading process, DS molecules exhibited highly affinity to these cationic hydrogels. Almost all the DS molecules in loading solution were absorbed and spread into the hydrogel. For drug release profiles, insulin-loaded hydrogel showed an initial rapid release and a sustained release. As a comparison, DS-loaded hydrogel exhibited a more sustained release profile. Results suggested salecan-g-PMAPTAC hydrogel could be a good candidate for anionic drug loading and delivery. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A feasibility study of a 3-day basal-bolus insulin delivery device in individuals with type 2 diabetes.

    PubMed

    Mader, Julia K; Lilly, Leslie C; Aberer, Felix; Korsatko, Stefan; Strock, Ellie; Mazze, Roger S; Damsbo, Peter; Pieber, Thomas R

    2014-05-01

    This study tested the feasibility of transition from multiple daily injections (MDI) to a 3-day, basal-bolus insulin delivery device (PaQ) for type 2 diabetes (T2D). Twenty MDI-treated individuals with T2D with HbA(1c) ≤9% (75 mmol/mol) were enrolled in a single-center, single-arm pilot study, lasting three 2-week periods: baseline (MDI), transition to PaQ, and PaQ therapy. Feasibility of use, glycemic control, safety, and patient satisfaction were assessed. Nineteen participants transitioned to PaQ treatment and demonstrated competency in assembling, placing, and using the device. Self-monitored blood glucose and blinded continuous glucose-monitoring data showed glycemic control similar to MDI. Study participants reported high satisfaction and device acceptance. PaQ treatment is both feasible and acceptable in individuals with T2D. Transition from MDI is easy and safe. PaQ treatment might lead to better therapy adherence and improvements in glycemic control and clinical outcomes.

  10. Recent Updates on Type 1 Diabetes Mellitus Management for Clinicians

    PubMed Central

    Iqbal, Ahmed; Novodvorsky, Peter

    2018-01-01

    Type 1 diabetes mellitus (T1DM) is a chronic autoimmune condition that requires life-long administration of insulin. Optimal management of T1DM entails a good knowledge and understanding of this condition both by the physician and the patient. Recent introduction of novel insulin preparations, technological advances in insulin delivery and glucose monitoring, such as continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring and improved understanding of the detrimental effects of hypoglycaemia and hyperglycaemia offer new opportunities and perspectives in T1DM management. Evidence from clinical trials suggests an important role of structured patient education. Our efforts should be aimed at improved metabolic control with concomitant reduction of hypoglycaemia. Despite recent advances, these goals are not easy to achieve and can put significant pressure on people with T1DM. The approach of physicians should therefore be maximally supportive. In this review, we provide an overview of the recent advances in T1DM management focusing on novel insulin preparations, ways of insulin administration and glucose monitoring and the role of metformin or sodium-glucose co-transporter 2 inhibitors in T1DM management. We then discuss our current understanding of the effects of hypoglycaemia on human body and strategies aimed at mitigating the risks associated with hypoglycaemia. PMID:29504302

  11. Shape Effect in the Design of Nanowire Coated Microparticles as Transepithelial Drug Delivery Devices

    PubMed Central

    Uskoković, Vuk; Lee, Kunwoo; Lee, Phin Peng; Fischer, Kathleen E.; Desai, Tejal A.

    2012-01-01

    While the oral drug delivery route has traditionally been the most popular among patients, it is estimated that 90 % of therapeutic compounds possess oral bioavailability limitations. Thus, the development of novel drug carriers for more effective oral delivery of therapeutics is an important goal. Composite particles made by growing nanoscopic silicon wires from the surface of narrowly dispersed, microsized silica beads were previously shown to be able to: (a) adhere well onto the epithelium by interdigitating their nanowires with the apical microvilli; and (b) increase the permeability of Caco-2 cell monolayers with respect to small organic molecules in direct proportion to their concentration. A comparison between the effects of spherical and planar particle morphologies on the permeability of the epithelial cell layer in vitro and in vivo presented the subject of this study. Owing to their larger surface area, the planar particles exhibited a higher drug loading efficiency than their spherical counterparts, while simultaneously increasing the transepithelial permeation of a moderately sized model drug, insulin. The insulin elution profile for planar nanowire-coated particles displayed a continual increase in the cumulative amount of the released drug, approaching a constant release rate for 1 – 4 h period of the elution time. An immunohistochemical study confirmed the ability of planar silica particles coated with nanowires to loosen the tight junction of the epithelial cells to a greater extent than the spherical particles did, thus enabling a more facile transport of the drug across the epithelium. Transepithelial permeability tests conducted for model drugs ranging in size from 0.4 to 150 kDa yielded three categories of molecules depending on their permeation propensities. Insulin belonged to the category of molecules deliverable across the epithelium only with the assistance of nanowire-coated particles. Other groups of drugs, smaller and bigger, respectively, either did not need the carrier to permeate the epithelium or were not able to cross it even with the support from the nanowire-coated particles. Bioavailability of insulin orally administered to rabbits was also found to be increased when delivered in conjunction with the nanowire-coated planar particles. PMID:22900471

  12. A novel validated model for the prediction of insulin therapy initiation and adverse perinatal outcomes in women with gestational diabetes mellitus.

    PubMed

    Barnes, Robyn A; Wong, Tang; Ross, Glynis P; Jalaludin, Bin B; Wong, Vincent W; Smart, Carmel E; Collins, Clare E; MacDonald-Wicks, Lesley; Flack, Jeff R

    2016-11-01

    Identifying women with gestational diabetes mellitus who are more likely to require insulin therapy vs medical nutrition therapy (MNT) alone would allow risk stratification and early triage to be incorporated into risk-based models of care. The aim of this study was to develop and validate a model to predict therapy type (MNT or MNT plus insulin [MNT+I]) for women with gestational diabetes mellitus (GDM). Analysis was performed of de-identified prospectively collected data (1992-2015) from women diagnosed with GDM by criteria in place since 1991 and formally adopted and promulgated as part of the more detailed 1998 Australasian Diabetes in Pregnancy Society management guidelines. Clinically relevant variables predictive of insulin therapy by univariate analysis were dichotomised and included in a multivariable regression model. The model was tested in a separate clinic population. In 3317 women, seven dichotomised significant independent predictors of insulin therapy were maternal age >30 years, family history of diabetes, pre-pregnancy obesity (BMI ≥30 kg/m(2)), prior GDM, early diagnosis of GDM (<24 weeks gestation), fasting venous blood glucose level (≥5.3 mmol/l) and HbA1c at GDM diagnosis ≥5.5% (≥37 mmol/mol). The requirement for MNT+I could be estimated according to the number of predictors present: 85.7-93.1% of women with 6-7 predictors required MNT+I compared with 9.3-14.7% of women with 0-1 predictors. This model predicted the likelihood of several adverse outcomes, including Caesarean delivery, early delivery, large for gestational age and an abnormal postpartum OGTT. The model was validated in a separate clinic population. This validated model has been shown to predict therapy type and the likelihood of several adverse perinatal outcomes in women with GDM.

  13. Thin-fat insulin-resistant phenotype also present in South Asian neonates born in the Netherlands.

    PubMed

    Karamali, N S; Ariëns, G A M; Kanhai, H H H; de Groot, C J M; Tamsma, J T; Middelkoop, B J C

    2015-02-01

    Several studies have shown that South Asian neonates have a characteristic thin-fat insulin-resistant phenotype. The aim of our study was to determine whether this phenotype is also present in South Asians who have migrated to a Western country (the Netherlands). South Asian and white Dutch pregnant women were included in our study. After delivery, cord blood was collected and neonatal anthropometry was measured within 72 h. Compared with white Dutch mothers, South Asian mothers were younger (28.5 v. 32.2 years, P<0.001) and had a higher prepregnancy body mass index (25.1 v. 23.0, P=0.001). Gestational age at delivery was on average 4 days shorter in South Asians (274.9 v. 278.8, P=0.001). To compare the two groups of neonates, we calculated sex- and gestation-specific s.d. scores using the values for mean and s.d. obtained from the white Dutch subjects as a reference. All measurements were smaller in South Asian neonates, except for those of the skinfolds. The largest difference was found in abdominal circumference (s.d. score 1.39, 95% CI -1.76 to -1.01). Triceps and subscapular skinfolds were similar in both groups (triceps s.d. score -0.34, 95% CI -0.88 to +0.20 and subscapular s.d. score -0.03, 95% CI -0.31 to +0.25). South Asian neonates had higher cord plasma levels of triglycerides (0.40 v. 0.36, P=0.614), glucose (5.4 v. 4.8, P=0.079) and insulin (6.3 v. 4.0, P=0.051). However, these differences were not statistically significant. After adjustment for birth weight, the difference in insulin became statistically significant (P=0.001). We therefore conclude that the thin-fat insulin-resistant phenotype is also present in South Asian neonates in the Netherlands.

  14. Rapid implantation of dissolving microneedles on an electrospun pillar array.

    PubMed

    Yang, Huisuk; Kim, Soyoung; Huh, Inyoung; Kim, Suyong; Lahiji, Shayan F; Kim, Miroo; Jung, Hyungil

    2015-09-01

    Dissolving microneedles (DMNs), designed to release drugs and dissolve after skin insertion, have been spotlighted as a novel transdermal delivery system due to their advantages such as minimal pain and tissue damage, ability to self-administer, and no associated hazardous residues. The drug delivery efficacy of DMNs, however, is limited by incomplete insertion and the extended period required for DMN dissolution. Here, we introduce a novel DMN delivery system, DMN on an electrospun pillar array (DEPA), which can rapidly implant DMNs into skin. DMNs were fabricated on a pillar array covered by a fibrous sheet produced by electrospinning PLGA solution (14%, w/v). DMNs were implanted into the skin by manual application (press and vibration for 10 s) by tearing of the fibers hung on the 300-μm pillars. Separation of DMNs from the fibrous sheet was dependent on both pillar height and the properties of the fibrous sheet. After evaluation of the implantation and dissolution of DMNs with diffusion of red dye by taking cross-sectional images of porcine skin, the hypoglycemic effect of insulin loaded DEPA was examined using a healthy mouse model. This DMN array overcomes critical issues associated with the low penetration efficiency of flat patch-based DMNs, and will allow realization of patient convenience with the desired drug efficacy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Fluorinated ionic liquids for protein drug delivery systems: Investigating their impact on the structure and function of lysozyme.

    PubMed

    Alves, Márcia; Vieira, Nicole S M; Rebelo, Luís Paulo N; Araújo, João M M; Pereiro, Ana B; Archer, Margarida

    2017-06-30

    Since the approval of recombinant human insulin by FDA in 1982, more than 200 proteins are currently available for pharmaceutical use to treat a wide range of diseases. However, innovation is still required to develop effective approaches for drug delivery. Our aim is to investigate the potential use of fluorinated ionic liquids (FILs) as drug delivery systems (DDS) for therapeutic proteins. Some initial parameters need to be assessed before further studies can proceed. This work evaluates the impact of FILs on the stability, function, structure and aggregation state of lysozyme. Different techniques were used for this purpose, which included differential scanning fluorimetry (DSF), spectrophotometric assays, circular dichroism (CD), dynamic light scattering (DLS), and scanning and transmission electron microscopy (SEM/TEM). Ionic liquids composed of cholinium-, imidazolium- or pyridinium- derivatives were combined with different anions and analysed at different concentrations in aqueous solutions (below and above the critical aggregation concentration, CAC). The results herein presented show that the addition of ionic liquids had no significant effect on the stability and hydrolytic activity of lysozyme. Moreover, a distinct behaviour was observed in DLS experiments for non-surfactant and surfactant ionic liquids, with the latter encapsulating the protein at concentrations above the CAC. These results encourage us to further study ionic liquids as promising tools for DDS of protein drugs. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Comparative efficacy and safety of oral antidiabetic drugs and insulin in treating gestational diabetes mellitus

    PubMed Central

    Liang, Hui-ling; Ma, Shu-juan; Xiao, Yan-ni; Tan, Hong-zhuan

    2017-01-01

    Abstract Background: The safety and efficacy of different drugs in treatment of gestational diabetes mellitus (GDM) patients who could not maintain normal glucose level only through diet and exercise remains to be debated. We performed this network meta-analysis (NAM) to compare and rank different antidiabetic drugs in glucose level control and pregnancy outcomes in GDM patients. Methods: We searched PubMed, Cochrane Library, Web of Science, and Embase up to December 31, 2016. Randomized controlled trials (RCTs) related to different drugs in the treatment of GDM patients were enrolled. We extracted the relevant information and assessed the risk of bias with the Cochrane risk of bias tool. We did pair-wise meta-analyses using the fixed-effects model or random-effects model and then adopted random-effects NAM combining both direct and indirect evidence within a Bayesian framework, to calculate the odds ratio (OR) or standardized mean difference (SMD) and to draw a surface under the cumulative ranking curve of the neonatal and maternal outcomes of different treatments in GDM patients. Results: Thirty-two randomized controlled trials (RCTs) were included in this NAM, including 6 kinds of treatments (metformin, metformin plus insulin, insulin, glyburide, acarbose, and placebo). The results of the NAM showed that regarding the incidence of macrosomia and LGA, metformin had lower incidence than glyburide (OR, 0.5411 and 0.4177). In terms of the incidence of admission to the NICU, insulin had higher incidence compared with glyburide (OR, 1.844). As for the incidence of neonatal hypoglycemia, metformin had lower incidence than insulin and glyburide (OR, 0.6331 and 0.3898), and insulin was lower than glyburide (OR, 0.6236). For mean birth weight, metformin plus insulin was lower than insulin (SMD, -0.5806), glyburide (SMD, -0.7388), and placebo (SMD, -0.6649). Besides, metformin was observed to have lower birth weight than glyburide (SMD, 0.2591). As for weight gain, metformin and metformin plus insulin were lower than insulin (SMD, -0.9166, -1.53). Ranking results showed that glyburide might be the optimum treatment regarding average glucose control, and metformin is the fastest in glucose control for GDM patients; glyburide have the highest incidence of macrosomia, preeclampsia, hyperbilirubinemia, neonatal hypoglycemia, shortest gestational age at delivery, and lowest mean birth weight; metformin (plus insulin when required) have the lowest incidence of macrosomia, PIH, LGA, RDS, low gestational age at delivery, and low birth weight. Besides, insulin had the highest incidence of NICU admission, acarbose had the lowest risk of neonatal hypoglycemia. Conclusion: Our study concluded that metformin is fastest in glucose control, with a more favorable pregnancy outcomes—would be a better option, but its rate of glucose control is the lowest.However, glyburide is the optimumtreatment regarding the rate of glucose control, but withmore adverse outcomes. This NAMbased on 32 RCTs will strongly help to guide further development of management for GDM patients, clinicians should carefully balance the risk–benefit profile of different treatments according to various situations. PMID:28930827

  17. Effects of Regular and Long-Acting Insulin on Cognition and Alzheimer's Disease Biomarkers: A Pilot Clinical Trial.

    PubMed

    Craft, Suzanne; Claxton, Amy; Baker, Laura D; Hanson, Angela J; Cholerton, Brenna; Trittschuh, Emily H; Dahl, Deborah; Caulder, Erin; Neth, Bryan; Montine, Thomas J; Jung, Youngkyoo; Maldjian, Joseph; Whitlow, Christopher; Friedman, Seth

    2017-01-01

    Long acting insulin detemir administered intranasally for three weeks enhanced memory for adults with Alzheimer's disease dementia (AD) or amnestic mild cognitive impairment (MCI). The investigation of longer-term administration is necessary to determine whether benefits persist, whether they are similar to benefits provided by regular insulin, and whether either form of insulin therapy affects AD biomarkers. The present study aimed to determine whether four months of treatment with intranasal insulin detemir or regular insulin improves cognition, daily functioning, and AD biomarkers for adults with MCI or AD. This randomized, double-blind, placebo-controlled trial included an intent-to-treat sample consisting of 36 adults diagnosed with MCI or mild to moderate AD. Participants received placebo (n = 12), 40 IU of insulin detemir (n = 12), or 40 IU of regular insulin (n = 12) daily for four months, administered with a nasal delivery device. A cognitive battery was administered at baseline and after two and four months of treatment. MRI was administered for all participants and lumbar puncture for a subset (n = 20) at baseline and four months. The primary outcome was change from baseline to four months on a memory composite (sum of Z scores for delayed list and story recall). Secondary outcomes included: global cognition (Alzheimer's Disease Assessment Scale-Cognition), daily functioning (Dementia Severity Rating Scale), MRI volume changes in AD-related regions of interest, and cerebrospinal fluid AD markers. The regular insulin treated group had better memory after two and four months compared with placebo (p < 0.03). No significant effects were observed for the detemir-assigned group compared with the placebo group, or for daily functioning for either group. Regular insulin treatment was associated with preserved volume on MRI. Regular insulin treatment was also associated with reduction in the tau-P181/Aβ42 ratio. Future research is warranted to examine the mechanistic basis of treatment differences, and to further assess the efficacy and safety of intranasal insulin.

  18. Determination of diffusion coefficient for released nanoparticles from developed gelatin/chitosan bilayered buccal films.

    PubMed

    Mahdizadeh Barzoki, Zahra; Emam-Djomeh, Zahra; Mortazavian, Elaheh; Rafiee-Tehrani, Niyousha; Behmadi, Homa; Rafiee-Tehrani, Morteza; Moosavi-Movahedi, Ali Akbar

    2018-06-01

    This study aims at the mathematical optimization by Box-Behnken statistical design, fabrication by ionic gelation technique and in vitro characterization of insulin nanoparticles containing thiolated N- dimethyl ethyl chitosan (DMEC-Cys) conjugate. Then Optimized insulin nanoparticles were loaded into the buccal film, and in-vitro drug release from films was investigated, and diffusion coefficient was predicted. The optimized nanoparticles were shown to have mean particle size diameter of 148nm, zeta potential of 15.5mV, PdI of 0.26 and AE of 97.56%. Cell viability after incubation with optimized nanoparticles and films were assessed using an MTT biochemical assay. In vitro release study, FTIR and cytotoxicity also indicated that nanoparticles made of this thiolated polymer are suitable candidates for oral insulin delivery. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Acylcarnitines as markers of exercise-associated fuel partitioning, xenometabolism, and potential signals to muscle afferent neurons

    USDA-ARS?s Scientific Manuscript database

    With insulin-resistance or type 2 diabetes mellitus, mismatches between mitochondrial fatty acid fuel delivery and oxidative phosphorylation/tricarboxylic acid cycle activity may contribute to inordinate accumulation of short- or medium-chain acylcarnitine fatty acid derivatives (markers of incomple...

  20. 76 FR 36539 - Scientific Information Request on Insulin Delivery and Glucose Monitoring Devices for Diabetes...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Agency for Healthcare Research and Quality Scientific... for Healthcare Research and Quality (AHRQ), HHS. ACTION: Request for scientific information submissions. SUMMARY: The Agency for Healthcare Research and Quality (AHRQ) is seeking scientific information...

  1. [Studies of diet management and insulin resistance in obese pregnant women].

    PubMed

    Takeda, S; Saitoh, M; Kinoshita, K; Sakamoto, S

    1992-02-01

    In an attempt to determine the principles of diet management in obese pregnant women, the association between maternal weight gain during pregnancy (Group I; weight reduction, Group II; +0-4 kg, Group III; +5-9 kg, Group IV; +10 kg-) and the incidence of the complications was investigated in 151 obese pregnant women. Studies on glucose tolerance and insulin binding to erythrocytes were also undertaken. 1) In Group I, the incidences of C/S, forceps delivery, prolonged labor and complication of PIH were lower than those of other groups. There were no heavy-for-dates and light-for-dates babies in Group I, differing from the other three groups. 2) Plasma levels of glucose and insulin were high in obese pregnant women on 75 g OGTT in the second trimester. The binding sites of insulin to erythrocytes were significantly decreased in obese pregnant women. In conclusion, the risks of pregnancy complicated by obesity were high. Insulin resistance was a characteristic of obese pregnant women. The results of this study suggested that the nutritional requirements for very obese pregnant women should be restricted to maintaining the same weight or losing weight during the course of pregnancy to minimize maternal and perinatal risks.

  2. Subconjunctivally Implantable Hydrogels with Degradable and Thermoresponsive Properties for Sustained Release of Insulin to the Retina

    PubMed Central

    Misra, Gauri P.; Singh, Ravi S.J.; Aleman, Tomas S.; Jacobson, Samuel G.; Gardner, Thomas W.; Lowe, Tao L.

    2009-01-01

    The objective of this work is to develop subconjunctivally implantable, biodegradable hydrogels for sustained release of intact insulin to the retina to prevent and treat retinal neurovascular degeneration such as diabetic retinopathy. The hydrogels are synthesized by UV photopolymerization of N-isopropylacrylamide (NIPAAm) monomer and a dextran macromer containing multiple hydrolytically degradable oligolactate-(2-hydroxyetheyl methacrylate) units (Dex-lactateHEMA) in 25:75 (v:v) ethanol:water mixture solvent. Insulin is loaded into the hydrogels during the synthesis process with loading efficiency up to 98%. The hydrogels can release biologically active insulin in vitro for at least one week and the release kinetics can be modulated by varying the ratio between NIPAAm and Dex-lactateHEMA and altering the physical size of the hydrogels. The hydrogels are not toxic to R28 retinal neuron cells in culture medium with 100% cell viability. The hydrogels can be implanted under the conjunctiva without causing adverse effects to the retina based on hematoxylin and eosin stain, immunostaining for microglial cell activation, and electroretinography. These subconjunctivally implantable hydrogels have potential for long-term periocular delivery of insulin or other drugs to treat diabetic retinopathy and other retinal diseases. PMID:19709741

  3. Dietary fructose in pregnancy induces hyperglycemia, hypertension, and pathologic kidney and liver changes in a rodent model.

    PubMed

    Shortliffe, Linda M Dairiki; Hammam, Olfat; Han, Xiaoyuan; Kouba, Erik; Tsao, Philip S; Wang, Bingyin

    2015-10-01

    The incidence of pregnancies complicated by hyperglycemia and hypertension is increasing along with associated morbidities to mother and offspring. The high fructose diet is a well-studied model that induces hyperglycemia and hypertension in male rodents, but may not affect females. We hypothesized that the physiologic stress of pregnancy may alter metabolic responses to dietary fructose. In this study female Sprague-Dawley rats were divided into two gestational dietary groups: (1) 60% carbohydrate standard rat chow (Pregnant-S-controls) and (2) 60% fructose enriched chow (Pregnant-F). Body weight, blood pressure, blood glucose, triglycerides, and insulin were measured in pregnancy and during the post-partum period. Maternal organ weight and histological changes were also assessed after delivery. By midpregnancy Pregnant-F rats had increased weight, elevated blood pressure, higher fasting glucose, and elevated triglycerides compared with Pregnant-S rats. Both groups demonstrated elevated gestational insulin levels with signs of insulin resistance (increased HOMA-IR). Pregnant-F rats showed significant histopathologic hepatic steatosis and renal tubular changes characterized by tubular dilation and glomerulosclerosis. Our study provides a model in which dietary change during pregnancy can be examined. We demonstrate, moreover, that high dietary fructose ingestion in pregnant rats may result in profound systemic and pathologic changes not appreciated during routine pregnancy. Copyright © 2015 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

  4. Optimization of novel pentablock copolymer based composite formulation for sustained delivery of peptide/protein in the treatment of ocular diseases

    PubMed Central

    Patel, Sulabh P.; Vaishya, Ravi; Patel, Ashaben; Agrahari, Vibhuti; Pal, Dhananjay; Mitra, Ashim K.

    2016-01-01

    This manuscript is focused on the development of pentablock (PB) copolymer based sustained release formulation for the treatment of posterior segment ocular diseases. We have successfully synthesized biodegradable and biocompatible PB copolymers for the preparation of nanoparticles (NPs) and thermosensitive gel. Achieving high drug loading with hydrophilic biotherapeutics (peptides /proteins) is a challenging task. Moreover, small intravitreal injection volume (≤100 μL) requires high loading to develop a long term (6 months) sustained release formulation. We have successfully investigated various formulation parameters to achieve maximum peptide/protein (octreotide, insulin, lysozyme, IgG-Fab, IgG, and catalase) loading in PB NPs. Improvement in drug loading can facilitate delivery of larger doses of therapeutic proteins via limited injection volume. A composite formulation comprised of NPs in gel system exhibited sustained release (without burst effect) of peptides and proteins, may serve as a platform technology for the treatment of posterior segment ocular diseases. PMID:26964498

  5. Efficacy of sustained delivery of GC-1 from a Nanofluidic system in a spontaneously obese non-human primate: a case study.

    PubMed

    Filgueira, Carly S; Bruno, Giacomo; Smith, Zachary W; Chua, Corrine Ying Xuan; Ballerini, Andrea; Folci, Marco; Gilbert, April L; Jain, Priya; Sastry, Jagannadha K; Nehete, Pramod N; Shelton, Kathryn A; Hill, Lori R; Ali, Areeba; Youker, Keith A; Grattoni, Alessandro

    2018-06-18

    With nearly 40% of U.S. adults obese, and childhood and adolescent rates rising, obesity and associated comorbidities are serious public health concerns with massive societal costs. Often, lifestyle interventions do not offer sufficient weight loss to improve health, requiring surgery and medications as adjunct management strategies. Here, we present a 4-month case study in which the sustained, low-dose, and constant administration of the thyroid receptor β selective agonist GC-1 (sobetirome) from a novel nanochannel membrane implant was assessed in an obese, pre-diabetic rhesus macaque. Dramatic loss of white adipose tissue in the abdomen from 36 to 18% was observed via magnetic resonance imaging in conjunction with normalized serum insulin and glycemia, with no signs of cardiotoxicity shown. The non-human primate study highlights sustained low-dose delivery of GC-1 from our minimally invasive subcutaneous implant as a valuable approach to induce weight loss and manage obesity and comorbidities, including type 2 diabetes.

  6. Needle-free nasal delivery of glucagon for treatment of diabetes-related severe hypoglycemia: toxicology of polypropylene resin used in delivery device.

    PubMed

    Reno, Frederick E; Edwards, C Nicholas; Bendix Jensen, Morten; Török-Bathó, Magdolna; Esdaile, David J; Piché, Claude; Triest, Myriam; Carballo, Dolorès

    2016-09-01

    The intranasal route is a promising route of administration for several emergency rescue drugs including naloxone and glucagon. Glucagon nasal powder (GNP) is a novel, needle-free delivery system for intranasal administration of glucagon for the treatment of severe hypoglycemia, an infrequent but serious complication of insulin use in patients with diabetes. The GNP delivery device is a compact, highly portable, single-use nasal powder dosing device constructed of polypropylene that allows for simple, single-step administration. To evaluate the toxicological profile of the polypropylene resin used in the actuator part of the delivery device that will contact skin and nasal mucosal membranes of the patient, we performed an in vitro cytotoxicity study, a skin sensitization study and an irritation (intracutaneous reactivity) study in animal models. Extracts of the actuator of the GNP device were generated from HAM F12 medium with 10% fetal bovine serum, 0.9% sodium chloride (NaCl) or sesame oil. The in vitro cytotoxicity test was performed in cultured L929 mouse fibroblasts. Skin sensitization analysis was performed in 10 guinea pigs according to the Magnusson-Kligman method, using a maximization method with Freund's Complete Adjuvant. Irritation following intracutaneous/intradermal treatment with device extracts (NaCl and sesame oil extractants) was assessed in three New Zealand White rabbits. In vitro cytotoxicity test: Both undiluted and diluted extract showed no toxicity (i.e. no abnormal morphology, cell death or cell lysis) toward L929 fibroblasts (cytotoxicity grade 0). Sensitization test in guinea pigs: Challenge with device extracts did not evoke positive responses in test animals previously induced with device extracts. The net response value represented an incidence rate of 0% and a net dermal irritation score value of 0.00. Irritation (intracutaneous/intradermal) test in New Zealand White rabbits: Device extracts and corresponding vehicle controls caused similar irritation reactions. The difference between the mean scores for the device extracts and the corresponding vehicle controls was less than 1.0. Extracts of the polypropylene resin of the GNP delivery device are not cytotoxic, do not result in dermal sensitization and do not cause irritation when applied topically or intracutaneously. Given the infrequent use and very short duration of exposure to the nasal mucosa during administration of GNP, the polypropylene resin of the GNP device actuator will likely not cause adverse dermal sensitization effects or irritation effects in humans and can, therefore, be considered for use as a delivery device in clinical trials assessing the efficacy and safety of GNP for the treatment of insulin-using patients experiencing episodes of severe hypoglycemia.

  7. Multiplex Conditional Mutagenesis Using Transgenic Expression of Cas9 and sgRNAs

    PubMed Central

    Yin, Linlin; Maddison, Lisette A.; Li, Mingyu; Kara, Nergis; LaFave, Matthew C.; Varshney, Gaurav K.; Burgess, Shawn M.; Patton, James G.; Chen, Wenbiao

    2015-01-01

    Determining the mechanism of gene function is greatly enhanced using conditional mutagenesis. However, generating engineered conditional alleles is inefficient and has only been widely used in mice. Importantly, multiplex conditional mutagenesis requires extensive breeding. Here we demonstrate a system for one-generation multiplex conditional mutagenesis in zebrafish (Danio rerio) using transgenic expression of both cas9 and multiple single guide RNAs (sgRNAs). We describe five distinct zebrafish U6 promoters for sgRNA expression and demonstrate efficient multiplex biallelic inactivation of tyrosinase and insulin receptor a and b, resulting in defects in pigmentation and glucose homeostasis. Furthermore, we demonstrate temporal and tissue-specific mutagenesis using transgenic expression of Cas9. Heat-shock-inducible expression of cas9 allows temporal control of tyr mutagenesis. Liver-specific expression of cas9 disrupts insulin receptor a and b, causing fasting hypoglycemia and postprandial hyperglycemia. We also show that delivery of sgRNAs targeting ascl1a into the eye leads to impaired damage-induced photoreceptor regeneration. Our findings suggest that CRISPR/Cas9-based conditional mutagenesis in zebrafish is not only feasible but rapid and straightforward. PMID:25855067

  8. Antenatal Corticosteroids Alter Insulin Signaling Pathways in Fetal Baboon Skeletal Muscle

    PubMed Central

    BLANCO, Cynthia L.; MOREIRA, Alvaro G.; McGILL, Lisa L.; ANZUETO, Diana G.; NATHANIELSZ, Peter; MUSI, Nicolas

    2015-01-01

    Objective We hypothesize that prenatal exposure to glucocorticoids (GCs) will negatively alter the insulin signal transduction pathway and has differing effects on the fetus according to gestational age at exposure. Methods Twenty-three fetal baboons were delivered from twenty-three healthy, non-diabetic mothers. Twelve preterm (0.67 gestational age) and eleven near term (0.95 gestational age) baboons were euthanized immediately after delivery. Half of the pregnant baboons at each gestation received two doses of intramuscular betamethasone 24-hours apart (170 μg.kg−1) before delivery, while the other half received no intervention. Vastus lateralis muscle was obtained from postnatal animals to measure protein content and gene expression of insulin receptor (IR)-β, IR-β Tyr 1361 phosphorylation (pIR-β), IR substate-1 (IRS-1), IRS-1 tyrosine phosphorylation (pIRS-1), p85 subunit of PI3-kinase (p85), Akt (Protein Kinase B), phospho-Akt Ser473 (pAkt), Akt-1, Akt-2, and glucose transporters (GLUT1 and GLUT4). Results Skeletal muscle from preterm baboons exposed to glucocorticoids had markedly reduced protein content of Akt and Akt-1 (respectively, 73% and 72% from 0.67 gestational age Control, P<0.001); IR-β and pIR-β were decreased (respectively, 94% and 85%, P<0.01) in the muscle of premature GC exposed fetuses, but not in term fetuses. GLUT1 and GLUT4 tended to increase with GC exposure in preterm animals (P=0.09), while GLUT4 increased 6.0 fold in term animals after GC exposure (P<0.05). Conclusion Exposure to a single course of antenatal GCs during fetal life alters the insulin-signaling pathway in fetal muscle in a manner dependent on the stage of gestation. PMID:24756099

  9. Antenatal corticosteroids alter insulin signaling pathways in fetal baboon skeletal muscle.

    PubMed

    Blanco, Cynthia L; Moreira, Alvaro G; McGill-Vargas, Lisa L; Anzueto, Diana G; Nathanielsz, Peter; Musi, Nicolas

    2014-05-01

    We hypothesize that prenatal exposure to glucocorticoids (GCs) negatively alters the insulin signal transduction pathway and has differing effects on the fetus according to gestational age (GA) at exposure. Twenty-three fetal baboons were delivered from 23 healthy, nondiabetic mothers. Twelve preterm (0.67 GA) and 11 near-term (0.95 GA) baboons were killed immediately after delivery. Half of the pregnant baboons at each gestation received two doses of i.m. betamethasone 24 h apart (170 μg/kg) before delivery, while the other half received no intervention. Vastus lateralis muscle was obtained from postnatal animals to measure the protein content and gene expression of insulin receptor β (IRβ; INSR), IRβ Tyr 1361 phosphorylation (pIRβ), IR substrate 1 (IRS1), IRS1 tyrosine phosphorylation (pIRS1), p85 subunit of PI3-kinase, AKT (protein kinase B), phospho-AKT Ser473 (pAKT), AKT1, AKT2, and glucose transporters (GLUT1 and GLUT4). Skeletal muscle from preterm baboons exposed to GCs had markedly reduced protein content of AKT and AKT1 (respectively, 73 and 72% from 0.67 GA control, P<0.001); IRβ and pIRβ were also decreased (respectively, 94 and 85%, P<0.01) in the muscle of premature GC-exposed fetuses but not in term fetuses. GLUT1 and GLUT4 tended to increase with GC exposure in preterm animals (P=0.09), while GLUT4 increased sixfold in term animals after exposure to GC (P<0.05). In conclusion, exposure to a single course of antenatal GCs during fetal life alters the insulin signaling pathway in fetal muscle in a manner dependent on the stage of gestation.

  10. Amperometric Glucose Sensors: Sources of Error and Potential Benefit of Redundancy

    PubMed Central

    Castle, Jessica R.; Kenneth Ward, W.

    2010-01-01

    Amperometric glucose sensors have advanced the care of patients with diabetes and are being studied to control insulin delivery in the research setting. However, at times, currently available sensors demonstrate suboptimal accuracy, which can result from calibration error, sensor drift, or lag. Inaccuracy can be particularly problematic in a closed-loop glycemic control system. In such a system, the use of two sensors allows selection of the more accurate sensor as the input to the controller. In our studies in subjects with type 1 diabetes, the accuracy of the better of two sensors significantly exceeded the accuracy of a single, randomly selected sensor. If an array with three or more sensors were available, it would likely allow even better accuracy with the use of voting. PMID:20167187

  11. Paediatrics, insulin resistance and the kidney.

    PubMed

    Marlais, Matko; Coward, Richard J

    2015-08-01

    Systemic insulin resistance is becoming more prevalent in the young due to modern lifestyles predisposing to the metabolic syndrome and obesity. There is also evidence that there are critical insulin-resistant phases for the developing child, including puberty, and that renal disease per se causes systemic insulin resistance. This review considers the factors that render children insulin resistant, as well as the accumulating evidence that the kidney is an insulin-responsive organ and could be affected by insulin resistance.

  12. Interleukin-1β inhibits insulin signaling and prevents insulin-stimulated system A amino acid transport in primary human trophoblasts.

    PubMed

    Aye, Irving L M H; Jansson, Thomas; Powell, Theresa L

    2013-12-05

    Interleukin-1β (IL-1β) promotes insulin resistance in tissues such as liver and skeletal muscle; however the influence of IL-1β on placental insulin signaling is unknown. We recently reported increased IL-1β protein expression in placentas of obese mothers, which could contribute to insulin resistance. In this study, we tested the hypothesis that IL-1β inhibits insulin signaling and prevents insulin-stimulated amino acid transport in cultured primary human trophoblast (PHT) cells. Cultured trophoblasts isolated from term placentas were treated with physiological concentrations of IL-1β (10pg/ml) for 24h. IL-1β increased the phosphorylation of insulin receptor substrate-1 (IRS-1) at Ser307 (inhibitory) and decreased total IRS-1 protein abundance but did not affect insulin receptor β expression. Furthermore, IL-1β inhibited insulin-stimulated phosphorylation of IRS-1 (Tyr612, activation site) and Akt (Thr308) and prevented insulin-stimulated increase in PI3K/p85 and Grb2 protein expression. IL-1β alone stimulated cRaf (Ser338), MEK (Ser221) and Erk1/2 (Thr202/Tyr204) phosphorylation. The inflammatory pathways nuclear factor kappa B and c-Jun N-terminal kinase, which are involved in insulin resistance, were also activated by IL-1β treatment. Moreover, IL-1β inhibited insulin-stimulated System A, but not System L amino acid uptake, indicating functional impairment of insulin signaling. In conclusion, IL-1β inhibited the insulin signaling pathway by inhibiting IRS-1 signaling and prevented insulin-stimulated System A transport, thereby promoting insulin resistance in cultured PHT cells. These findings indicate that conditions which lead to increased systemic maternal or placental IL-1β levels may attenuate the effects of maternal insulin on placental function and consequently fetal growth. Published by Elsevier Ireland Ltd.

  13. Interleukin-1β Inhibits Insulin Signaling and Prevents Insulin-Stimulated System A Amino Acid Transport in Primary Human Trophoblasts

    PubMed Central

    Aye, Irving L. M. H.; Jansson, Thomas; Powell, Theresa L.

    2013-01-01

    Interleukin-1β (IL-1β) promotes insulin resistance in tissues such as liver and skeletal muscle; however the influence of IL-1β on placental insulin signaling is unknown. We recently reported increased IL-1β protein expression in placentas of obese mothers, which could contribute to insulin resistance. In this study, we tested the hypothesis that IL-1β inhibits insulin signaling and prevents insulin-stimulated amino acid transport in cultured primary human trophoblast (PHT) cells. Cultured trophoblasts isolated from term placentas were treated with physiological concentrations of IL-1β (10 pg/ml) for 24 hours. IL-1β increased the phosphorylation of insulin receptor substrate-1 (IRS-1) at Ser307 (inhibitory) and decreased total IRS-1 protein abundance but did not affect insulin receptor β expression. Furthermore, IL-1β inhibited insulin-stimulated phosphorylation of IRS-1 (Tyr612, activation site) and Akt (Thr308) and prevented insulin-stimulated increase in PI3K/p85 and Grb2 protein expression. IL-1β alone stimulated cRaf (Ser338), MEK (Ser221) and Erk1/2 (Thr202/Tyr204) phosphorylation. The inflammatory pathways nuclear factor kappa B and c-Jun N-terminal kinase, which are involved in insulin resistance, were also activated by IL-1β treatment. Moreover, IL-1β inhibited insulin-stimulated System A, but not System L amino acid uptake, indicating functional impairment of insulin signaling. In conclusion, IL-1β inhibited the insulin signaling pathway by inhibiting IRS-1 signaling and prevented insulin-stimulated System A transport, thereby promoting insulin resistance in cultured PHT cells. These findings indicate that conditions which lead to increased systemic maternal or placental IL-1β levels may attenuate the effects of maternal insulin on placental function and consequently fetal growth. PMID:23891856

  14. Quantification of the Glycemic Response to Microdoses of Subcutaneous Glucagon at Varying Insulin Levels

    PubMed Central

    Castle, Jessica R.; Bakhtiani, Parkash A.; Haidar, Ahmad; Branigan, Deborah L.; Breen, Matthew; Ward, W. Kenneth

    2014-01-01

    OBJECTIVE Glucagon delivery in closed-loop control of type 1 diabetes is effective in minimizing hypoglycemia. However, high insulin concentration lowers the hyperglycemic effect of glucagon, and small doses of glucagon in this setting are ineffective. There are no studies clearly defining the relationship between insulin levels, subcutaneous glucagon, and blood glucose. RESEARCH DESIGN AND METHODS Using a euglycemic clamp technique in 11 subjects with type 1 diabetes, we examined endogenous glucose production (EGP) of glucagon (25, 75, 125, and 175 μg) at three insulin infusion rates (0.016, 0.032, and 0.05 units/kg/h) in a randomized, crossover study. Infused 6,6-dideuterated glucose was measured every 10 min, and EGP was determined using a validated glucoregulatory model. Area under the curve (AUC) for glucose production was the primary outcome, estimated over 60 min. RESULTS At low insulin levels, EGP rose proportionately with glucagon dose, from 5 ± 68 to 112 ± 152 mg/kg (P = 0.038 linear trend), whereas at high levels, there was no increase in glucose output (19 ± 53 to 26 ± 38 mg/kg, P = NS). Peak glucagon serum levels and AUC correlated well with dose (r2 = 0.63, P < 0.001), as did insulin levels with insulin infusion rates (r2 = 0.59, P < 0.001). CONCLUSIONS EGP increases steeply with glucagon doses between 25 and 175 μg at lower insulin infusion rates. However, high insulin infusion rates prevent these doses of glucagon from significantly increasing glucose output and may reduce glucagon effectiveness in preventing hypoglycemia when used in the artificial pancreas. PMID:25139882

  15. Quantification of the glycemic response to microdoses of subcutaneous glucagon at varying insulin levels.

    PubMed

    El Youssef, Joseph; Castle, Jessica R; Bakhtiani, Parkash A; Haidar, Ahmad; Branigan, Deborah L; Breen, Matthew; Ward, W Kenneth

    2014-11-01

    Glucagon delivery in closed-loop control of type 1 diabetes is effective in minimizing hypoglycemia. However, high insulin concentration lowers the hyperglycemic effect of glucagon, and small doses of glucagon in this setting are ineffective. There are no studies clearly defining the relationship between insulin levels, subcutaneous glucagon, and blood glucose. Using a euglycemic clamp technique in 11 subjects with type 1 diabetes, we examined endogenous glucose production (EGP) of glucagon (25, 75, 125, and 175 μg) at three insulin infusion rates (0.016, 0.032, and 0.05 units/kg/h) in a randomized, crossover study. Infused 6,6-dideuterated glucose was measured every 10 min, and EGP was determined using a validated glucoregulatory model. Area under the curve (AUC) for glucose production was the primary outcome, estimated over 60 min. At low insulin levels, EGP rose proportionately with glucagon dose, from 5 ± 68 to 112 ± 152 mg/kg (P = 0.038 linear trend), whereas at high levels, there was no increase in glucose output (19 ± 53 to 26 ± 38 mg/kg, P = NS). Peak glucagon serum levels and AUC correlated well with dose (r2 = 0.63, P < 0.001), as did insulin levels with insulin infusion rates (r2 = 0.59, P < 0.001). EGP increases steeply with glucagon doses between 25 and 175 μg at lower insulin infusion rates. However, high insulin infusion rates prevent these doses of glucagon from significantly increasing glucose output and may reduce glucagon effectiveness in preventing hypoglycemia when used in the artificial pancreas. © 2014 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  16. Pharmacological vasodilation improves insulin-stimulated muscle protein anabolism but not glucose utilization in older adults.

    PubMed

    Timmerman, Kyle L; Lee, Jessica L; Fujita, Satoshi; Dhanani, Shaheen; Dreyer, Hans C; Fry, Christopher S; Drummond, Micah J; Sheffield-Moore, Melinda; Rasmussen, Blake B; Volpi, Elena

    2010-11-01

    Skeletal muscle protein metabolism is resistant to the anabolic action of insulin in healthy, nondiabetic older adults. This defect is associated with impaired insulin-induced vasodilation and mTORC1 signaling. We hypothesized that, in older subjects, pharmacological restoration of insulin-induced capillary recruitment would improve the response of muscle protein synthesis and anabolism to insulin. Twelve healthy, nondiabetic older subjects (71 ± 2 years) were randomized to two groups. Subjects were studied at baseline and during local infusion in one leg of insulin alone (Control) or insulin plus sodium nitroprusside (SNP) at variable rate to double leg blood flow. We measured leg blood flow by dye dilution; muscle microvascular perfusion with contrast enhanced ultrasound; Akt/mTORC1 signaling by Western blotting; and muscle protein synthesis, amino acid, and glucose kinetics using stable isotope methodologies. There were no baseline differences between groups. Blood flow, muscle perfusion, phenylalanine delivery to the leg, and intracellular availability of phenylalanine increased significantly (P < 0.05) in SNP only. Akt phosphorylation increased in both groups but increased more in SNP (P < 0.05). Muscle protein synthesis and net balance (nmol · min(-1) · 100 ml · leg(-1)) increased significantly (P < 0.05) in SNP (synthesis, 43 ± 6 to 129 ± 25; net balance, -16 ± 3 to 26 ± 12) but not in Control (synthesis, 41 ± 10 to 53 ± 8; net balance, -17 ± 3 to -2 ± 3). Pharmacological enhancement of muscle perfusion and amino acid availability during hyperinsulinemia improves the muscle protein anabolic effect of insulin in older adults.

  17. Mechanism of insulin resistance in normal pregnancy.

    PubMed

    Hodson, K; Man, C Dalla; Smith, F E; Thelwall, P E; Cobelli, C; Robson, S C; Taylor, R

    2013-08-01

    Normal pregnancy is associated with insulin resistance although the mechanism is not understood. Increased intramyocellular lipid is closely associated with the insulin resistance of type 2 diabetes and obesity, and the aim of this study was to determine whether this was so for the physiological insulin resistance of pregnancy. Eleven primiparous healthy pregnant women (age: 27-39 years, body mass index 24.0±3.1 kg/m2) and no personal or family history of diabetes underwent magnetic resonance studies to quantify intramyocellular lipid, plasma lipid fractions, and insulin sensitivity. The meal-related insulin sensitivity index was considerably lower in pregnancy (45.6±9.9 vs. 193.0±26.1; 10(-4) dl/kg/min per pmol/l, p=0.0002). Fasting plasma triglyceride levels were elevated 3-fold during pregnancy (2.3±0.2 vs. 0.8±0.1 mmol/l, p<0.01) and the low-density density lipoprotein fraction, responsible for fatty acid delivery to muscle and other tissues, was 6-fold elevated (0.75±0.43 vs. 0.12±0.09 mmol/l; p=0.001). However, mean intramyocellular lipid concentrations of the soleus muscle were not different during pregnancy (20.0±2.3 vs. 19.1±3.2 mmol/l, p=0.64). The pregnancy effect on muscle insulin resistance is distinct from that underlying type 2 diabetes. © Georg Thieme Verlag KG Stuttgart · New York.

  18. The Mitochondrial 2-Oxoglutarate Carrier Is Part of a Metabolic Pathway That Mediates Glucose- and Glutamine-stimulated Insulin Secretion*

    PubMed Central

    Odegaard, Matthew L.; Joseph, Jamie W.; Jensen, Mette V.; Lu, Danhong; Ilkayeva, Olga; Ronnebaum, Sarah M.; Becker, Thomas C.; Newgard, Christopher B.

    2010-01-01

    Glucose-stimulated insulin secretion from pancreatic islet β-cells is dependent in part on pyruvate cycling through the pyruvate/isocitrate pathway, which generates cytosolic α-ketoglutarate, also known as 2-oxoglutarate (2OG). Here, we have investigated if mitochondrial transport of 2OG through the 2-oxoglutarate carrier (OGC) participates in control of nutrient-stimulated insulin secretion. Suppression of OGC in clonal pancreatic β-cells (832/13 cells) and isolated rat islets by adenovirus-mediated delivery of small interfering RNA significantly decreased glucose-stimulated insulin secretion. OGC suppression also reduced insulin secretion in response to glutamine plus the glutamate dehydrogenase activator 2-amino-2-norbornane carboxylic acid. Nutrient-stimulated increases in glucose usage, glucose oxidation, glutamine oxidation, or ATP:ADP ratio were not affected by OGC knockdown, whereas suppression of OGC resulted in a significant decrease in the NADPH:NADP+ ratio during stimulation with glucose but not glutamine + 2-amino-2-norbornane carboxylic acid. Finally, OGC suppression reduced insulin secretion in response to a membrane-permeant 2OG analog, dimethyl-2OG. These data reveal that the OGC is part of a mechanism of fuel-stimulated insulin secretion that is common to glucose, amino acid, and organic acid secretagogues, involving flux through the pyruvate/isocitrate cycling pathway. Although the components of this pathway must remain intact for appropriate stimulus-secretion coupling, production of NADPH does not appear to be the universal second messenger signal generated by these reactions. PMID:20356834

  19. Childhood diabetes mellitus: recent advances & future prospects.

    PubMed

    Dejkhamron, Prapai; Menon, Ram K; Sperling, Mark A

    2007-03-01

    Diabetes mellitus (DM) is a metabolic disease characterized by absolute or relative insulin deficiency. Absolute deficiency of insulin most commonly results from an autoimmune destruction of insulin producing cells in the pancreas and in general, the term Type 1 DM (T1DM) is used to denote childhood diabetes associated with autoimmunity and absolute insulin deficiency. The term Type 2 DM (T2DM) is used to denote diabetes resulting from a relative deficiency of insulin when insulin secretion is inadequate to overcome co-existent resistance to insulin action on carbohydrate, protein or fat metabolism; T2DM is most commonly associated with the prototypic insulin resistant state of obesity. In the western hemisphere DM is one of the most prevalent chronic diseases in childhood, whereas the incidence of T1DM in developing countries is significantly less than that in the western hemisphere. Epidemiological studies indicate that there is gradual but steady increase in the incidence of both T1DM and T2DM in both developed and developing countries. This review provides an overview of the major advances in our understanding of the aetiology, pathogenesis, and clinical management of DM in children with the focus being on T1DM. Genetic predisposition, environmental causes, and emerging concepts of the pathogenesis of T1DM such as the accelerator hypothesis are discussed. The goals of treating a child with DM are to achieve normal growth and development with prevention of acute and chronic complications of DM. These goals are achieved by co-ordinated care delivered by a multidisciplinary team focusing on insulin administrations, glucose monitoring, meal planning, and screening for complications. Newer insulin analogues ("designer" insulin) and automated methods of delivery via programmable pumps have revolutionized the care of the child with diabetes. Though T1DM cannot yet be prevented, ongoing trials and strategies aimed at modulating the autoimmune response and the burgeoning science of embryonic stem cell biology, and isolating and propagating islet cell progenitor cells are discussed in this review.

  20. Preliminary Evaluation of a New Semi-Closed-Loop Insulin Therapy System Over the Prandial Period in Adult Patients With Type 1 Diabetes

    PubMed Central

    Quemerais, Marie Aude; Doron, Maeva; Dutrech, Florent; Melki, Vincent; Franc, Sylvia; Antonakios, Michel; Charpentier, Guillaume; Hanaire, Helene; Charpentier, Guillaume

    2014-01-01

    There is room for improvement in the algorithms used in closed-loop insulin therapy during the prandial period. This pilot study evaluated the efficacy and safety of the Diabeloop algorithm (model predictive control type) during the postprandial period. This 2-center clinical trial compared interstitial glucose levels over two 5-hour periods (with/without the algorithm) following a calibrated lunch. On the control day, the amount of insulin delivered by the pump was determined according to the patient’s usual parameters. On the test day, 50% or 75% of the theoretical bolus required was delivered, while the algorithm, informed of carbohydrate intake, proposed changes to insulin delivery every 15 minutes using modeling to forecast glucose levels. The primary endpoint was percentage of time spent at near normoglycemia (70-180 mg/dl). Twelve patients with type 1 diabetes (9 men, age 35.6 ± 12.7 years, HbA1c 7.3 ± 0.8%) were included. The percentage of time spent in the target range was 84.5 ± 20.8 (test day) versus 69.2 ± 33.9% (control day, P = .11). The percentage of time spent in hypoglycemia < 70 mg/dl was 0.2 ± 0.8 (test) versus 4.4 ± 8.2% (control, P = .18). Interstitial glucose at the end of the test (5 hours) was 127.5 ± 40.1 (test) versus 146 ± 53.5 mg/dl (control, P = .25). The insulin doses did not differ, and no differences were observed between the 50% and 75% boluses. In a semi-closed-loop configuration with manual priming boluses (25% or 50% reduction), the Diabeloop v1 algorithm was as successful as the manual method in determining the prandial bolus, without any exposure to excessive hypoglycemic risk. PMID:25097057

Top