Sample records for integer order pid

  1. Exploiting Fractional Order PID Controller Methods in Improving the Performance of Integer Order PID Controllers: A GA Based Approach

    NASA Astrophysics Data System (ADS)

    Mukherjee, Bijoy K.; Metia, Santanu

    2009-10-01

    The paper is divided into three parts. The first part gives a brief introduction to the overall paper, to fractional order PID (PIλDμ) controllers and to Genetic Algorithm (GA). In the second part, first it has been studied how the performance of an integer order PID controller deteriorates when implemented with lossy capacitors in its analog realization. Thereafter it has been shown that the lossy capacitors can be effectively modeled by fractional order terms. Then, a novel GA based method has been proposed to tune the controller parameters such that the original performance is retained even though realized with the same lossy capacitors. Simulation results have been presented to validate the usefulness of the method. Some Ziegler-Nichols type tuning rules for design of fractional order PID controllers have been proposed in the literature [11]. In the third part, a novel GA based method has been proposed which shows how equivalent integer order PID controllers can be obtained which will give performance level similar to those of the fractional order PID controllers thereby removing the complexity involved in the implementation of the latter. It has been shown with extensive simulation results that the equivalent integer order PID controllers more or less retain the robustness and iso-damping properties of the original fractional order PID controllers. Simulation results also show that the equivalent integer order PID controllers are more robust than the normal Ziegler-Nichols tuned PID controllers.

  2. A conformal mapping based fractional order approach for sub-optimal tuning of PID controllers with guaranteed dominant pole placement

    NASA Astrophysics Data System (ADS)

    Saha, Suman; Das, Saptarshi; Das, Shantanu; Gupta, Amitava

    2012-09-01

    A novel conformal mapping based fractional order (FO) methodology is developed in this paper for tuning existing classical (Integer Order) Proportional Integral Derivative (PID) controllers especially for sluggish and oscillatory second order systems. The conventional pole placement tuning via Linear Quadratic Regulator (LQR) method is extended for open loop oscillatory systems as well. The locations of the open loop zeros of a fractional order PID (FOPID or PIλDμ) controller have been approximated in this paper vis-à-vis a LQR tuned conventional integer order PID controller, to achieve equivalent integer order PID control system. This approach eases the implementation of analog/digital realization of a FOPID controller with its integer order counterpart along with the advantages of fractional order controller preserved. It is shown here in the paper that decrease in the integro-differential operators of the FOPID/PIλDμ controller pushes the open loop zeros of the equivalent PID controller towards greater damping regions which gives a trajectory of the controller zeros and dominant closed loop poles. This trajectory is termed as "M-curve". This phenomena is used to design a two-stage tuning algorithm which reduces the existing PID controller's effort in a significant manner compared to that with a single stage LQR based pole placement method at a desired closed loop damping and frequency.

  3. Design of distributed PID-type dynamic matrix controller for fractional-order systems

    NASA Astrophysics Data System (ADS)

    Wang, Dawei; Zhang, Ridong

    2018-01-01

    With the continuous requirements for product quality and safety operation in industrial production, it is difficult to describe the complex large-scale processes with integer-order differential equations. However, the fractional differential equations may precisely represent the intrinsic characteristics of such systems. In this paper, a distributed PID-type dynamic matrix control method based on fractional-order systems is proposed. First, the high-order approximate model of integer order is obtained by utilising the Oustaloup method. Then, the step response model vectors of the plant is obtained on the basis of the high-order model, and the online optimisation for multivariable processes is transformed into the optimisation of each small-scale subsystem that is regarded as a sub-plant controlled in the distributed framework. Furthermore, the PID operator is introduced into the performance index of each subsystem and the fractional-order PID-type dynamic matrix controller is designed based on Nash optimisation strategy. The information exchange among the subsystems is realised through the distributed control structure so as to complete the optimisation task of the whole large-scale system. Finally, the control performance of the designed controller in this paper is verified by an example.

  4. Performance analysis of two-degree of freedom fractional order PID controllers for robotic manipulator with payload.

    PubMed

    Sharma, Richa; Gaur, Prerna; Mittal, A P

    2015-09-01

    The robotic manipulators are multi-input multi-output (MIMO), coupled and highly nonlinear systems. The presence of external disturbances and time-varying parameters adversely affects the performance of these systems. Therefore, the controller designed for these systems should effectively deal with such complexities, and it is an intriguing task for control engineers. This paper presents two-degree of freedom fractional order proportional-integral-derivative (2-DOF FOPID) controller scheme for a two-link planar rigid robotic manipulator with payload for trajectory tracking task. The tuning of all controller parameters is done using cuckoo search algorithm (CSA). The performance of proposed 2-DOF FOPID controllers is compared with those of their integer order designs, i.e., 2-DOF PID controllers, and with the traditional PID controllers. In order to show effectiveness of proposed scheme, the robustness testing is carried out for model uncertainties, payload variations with time, external disturbance and random noise. Numerical simulation results indicate that the 2-DOF FOPID controllers are superior to their integer order counterparts and the traditional PID controllers. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  5. A uniform LMI formulation for tuning PID, multi-term fractional-order PID, and Tilt-Integral-Derivative (TID) for integer and fractional-order processes.

    PubMed

    Merrikh-Bayat, Farshad

    2017-05-01

    In this paper first the Multi-term Fractional-Order PID (MFOPID) whose transfer function is equal to [Formula: see text] , where k j and α j are unknown and known real parameters respectively, is introduced. Without any loss of generality, a special form of MFOPID with transfer function k p +k i /s+k d1 s+k d2 s μ where k p , k i , k d1 , and k d2 are unknown real and μ is a known positive real parameter, is considered. Similar to PID and TID, MFOPID is also linear in its parameters which makes it possible to study all of them in a same framework. Tuning the parameters of PID, TID, and MFOPID based on loop shaping using Linear Matrix Inequalities (LMIs) is discussed. For this purpose separate LMIs for closed-loop stability (of sufficient type) and adjusting different aspects of the open-loop frequency response are developed. The proposed LMIs for stability are obtained based on the Nyquist stability theorem and can be applied to both integer and fractional-order (not necessarily commensurate) processes which are either stable or have one unstable pole. Numerical simulations show that the performance of the four-variable MFOPID can compete the trivial five-variable FOPID and often excels PID and TID. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Fractional order PID controller for improvement of PMSM speed control in aerospace applications

    NASA Astrophysics Data System (ADS)

    Saraji, Ali Motalebi; Ghanbari, Mahmood

    2014-12-01

    Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loop of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.

  7. Fractional order PID controller for improvement of PMSM speed control in aerospace applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saraji, Ali Motalebi; Ghanbari, Mahmood

    Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loopmore » of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.« less

  8. Fractional Order PIλDμ Control for Maglev Guiding System

    NASA Astrophysics Data System (ADS)

    Hu, Qing; Hu, Yuwei

    To effectively suppress the external disturbances and parameter perturbation problem of the maglev guiding system, and improve speed and robustness, the electromagnetic guiding system is exactly linearized using state feedback method, Fractional calculus theory is introduced, the order of integer order PID control was extended to the field of fractional, then fractional order PIλDμ Controller was presented, Due to the extra two adjustable parameters compared with traditional PID controller, fractional order PIλDμ controllers were expected to show better control performance. The results of the computer simulation show that the proposed controller suppresses the external disturbances and parameter perturbation of the system effectively; the system response speed was increased; at the same time, it had flexible structure and stronger robustness.

  9. On the fragility of fractional-order PID controllers for FOPDT processes.

    PubMed

    Padula, Fabrizio; Visioli, Antonio

    2016-01-01

    This paper analyzes the fragility issue of fractional-order proportional-integral-derivative controllers applied to integer first-order plus-dead-time processes. In particular, the effects of the variations of the controller parameters on the achieved control system robustness and performance are investigated. Results show that this kind of controllers is more fragile with respect to the standard proportional-integral-derivative controllers and therefore a significant attention should be paid by the user in their tuning. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Study on Fuzzy Adaptive Fractional Order PIλDμ Control for Maglev Guiding System

    NASA Astrophysics Data System (ADS)

    Hu, Qing; Hu, Yuwei

    The mathematical model of the linear elevator maglev guiding system is analyzed in this paper. For the linear elevator needs strong stability and robustness to run, the integer order PID was expanded to the fractional order, in order to improve the steady state precision, rapidity and robustness of the system, enhance the accuracy of the parameter in fractional order PIλDμ controller, the fuzzy control is combined with the fractional order PIλDμ control, using the fuzzy logic achieves the parameters online adjustment. The simulations reveal that the system has faster response speed, higher tracking precision, and has stronger robustness to the disturbance.

  11. Fractional order fuzzy control of hybrid power system with renewable generation using chaotic PSO.

    PubMed

    Pan, Indranil; Das, Saptarshi

    2016-05-01

    This paper investigates the operation of a hybrid power system through a novel fuzzy control scheme. The hybrid power system employs various autonomous generation systems like wind turbine, solar photovoltaic, diesel engine, fuel-cell, aqua electrolyzer etc. Other energy storage devices like the battery, flywheel and ultra-capacitor are also present in the network. A novel fractional order (FO) fuzzy control scheme is employed and its parameters are tuned with a particle swarm optimization (PSO) algorithm augmented with two chaotic maps for achieving an improved performance. This FO fuzzy controller shows better performance over the classical PID, and the integer order fuzzy PID controller in both linear and nonlinear operating regimes. The FO fuzzy controller also shows stronger robustness properties against system parameter variation and rate constraint nonlinearity, than that with the other controller structures. The robustness is a highly desirable property in such a scenario since many components of the hybrid power system may be switched on/off or may run at lower/higher power output, at different time instants. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  12. Enhanced robust fractional order proportional-plus-integral controller based on neural network for velocity control of permanent magnet synchronous motor.

    PubMed

    Zhang, Bitao; Pi, YouGuo

    2013-07-01

    The traditional integer order proportional-integral-differential (IO-PID) controller is sensitive to the parameter variation or/and external load disturbance of permanent magnet synchronous motor (PMSM). And the fractional order proportional-integral-differential (FO-PID) control scheme based on robustness tuning method is proposed to enhance the robustness. But the robustness focuses on the open-loop gain variation of controlled plant. In this paper, an enhanced robust fractional order proportional-plus-integral (ERFOPI) controller based on neural network is proposed. The control law of the ERFOPI controller is acted on a fractional order implement function (FOIF) of tracking error but not tracking error directly, which, according to theory analysis, can enhance the robust performance of system. Tuning rules and approaches, based on phase margin, crossover frequency specification and robustness rejecting gain variation, are introduced to obtain the parameters of ERFOPI controller. And the neural network algorithm is used to adjust the parameter of FOIF. Simulation and experimental results show that the method proposed in this paper not only achieve favorable tracking performance, but also is robust with regard to external load disturbance and parameter variation. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  13. Multi-objective LQR with optimum weight selection to design FOPID controllers for delayed fractional order processes.

    PubMed

    Das, Saptarshi; Pan, Indranil; Das, Shantanu

    2015-09-01

    An optimal trade-off design for fractional order (FO)-PID controller is proposed with a Linear Quadratic Regulator (LQR) based technique using two conflicting time domain objectives. A class of delayed FO systems with single non-integer order element, exhibiting both sluggish and oscillatory open loop responses, have been controlled here. The FO time delay processes are handled within a multi-objective optimization (MOO) formalism of LQR based FOPID design. A comparison is made between two contemporary approaches of stabilizing time-delay systems withinLQR. The MOO control design methodology yields the Pareto optimal trade-off solutions between the tracking performance and total variation (TV) of the control signal. Tuning rules are formed for the optimal LQR-FOPID controller parameters, using median of the non-dominated Pareto solutions to handle delayed FO processes. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  14. The generalised isodamping approach for robust fractional PID controllers design

    NASA Astrophysics Data System (ADS)

    Beschi, M.; Padula, F.; Visioli, A.

    2017-06-01

    In this paper, we present a novel methodology to design fractional-order proportional-integral-derivative controllers. Based on the description of the controlled system by means of a family of linear models parameterised with respect to a free variable that describes the real process operating point, we design the controller by solving a constrained min-max optimisation problem where the maximum sensitivity has to be minimised. Among the imposed constraints, the most important one is the new generalised isodamping condition, that defines the invariancy of the phase margin with respect to the free parameter variations. It is also shown that the well-known classical isodamping condition is a special case of the new technique proposed in this paper. Simulation results show the effectiveness of the proposed technique and the superiority of the fractional-order controller compared to its integer counterpart.

  15. An Implementation Method of the Fractional-Order PID Control System Considering the Memory Constraint and its Application to the Temperature Control of Heat Plate

    NASA Astrophysics Data System (ADS)

    Sasano, Koji; Okajima, Hiroshi; Matsunaga, Nobutomo

    Recently, the fractional order PID (FO-PID) control, which is the extension of the PID control, has been focused on. Even though the FO-PID requires the high-order filter, it is difficult to realize the high-order filter due to the memory limitation of digital computer. For implementation of FO-PID, approximation of the fractional integrator and differentiator are required. Short memory principle (SMP) is one of the effective approximation methods. However, there is a disadvantage that the approximated filter with SMP cannot eliminate the steady-state error. For this problem, we introduce the distributed implementation of the integrator and the dynamic quantizer to make the efficient use of permissible memory. The objective of this study is to clarify how to implement the accurate FO-PID with limited memories. In this paper, we propose the implementation method of FO-PID with memory constraint using dynamic quantizer. And the trade off between approximation of fractional elements and quantized data size are examined so as to close to the ideal FO-PID responses. The effectiveness of proposed method is evaluated by numerical example and experiment in the temperature control of heat plate.

  16. A closer look at the lower-order structure of the Personality Inventory for DSM-5: comparison with the Five-Factor Model.

    PubMed

    Griffin, Sarah A; Samuel, Douglas B

    2014-10-01

    The Personality Inventory for DSM-5 (PID-5) was developed as a measure of the maladaptive personality trait model included within Section III of the DSM-5. Although preliminary findings have suggested the PID-5 has a five-factor structure that overlaps considerably with the Five-Factor Model (FFM) at the higher order level, there has been much less attention on the specific locations of the 25 lower-order traits. Joint exploratory factor analysis of the PID-5 traits and the 30 facets of the NEO-PI-R were used to determine the lower-order structure of the PID-5. Results indicated the PID-5's domain-level structure closely resembled the FFM. We also explored the placement of several lower-order facets that have not loaded consistently in previous studies. Overall, these results indicate that the PID-5 shares a common structure with the FFM and clarify the placement of some interstitial facets. More research investigating the lower-order facets is needed to determine how they fit into the hierarchical structure and explicate their relationships to existing measures of pathological traits. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  17. Two degree of freedom internal model control-PID design for LFC of power systems via logarithmic approximations.

    PubMed

    Singh, Jay; Chattterjee, Kalyan; Vishwakarma, C B

    2018-01-01

    Load frequency controller has been designed for reduced order model of single area and two-area reheat hydro-thermal power system through internal model control - proportional integral derivative (IMC-PID) control techniques. The controller design method is based on two degree of freedom (2DOF) internal model control which combines with model order reduction technique. Here, in spite of taking full order system model a reduced order model has been considered for 2DOF-IMC-PID design and the designed controller is directly applied to full order system model. The Logarithmic based model order reduction technique is proposed to reduce the single and two-area high order power systems for the application of controller design.The proposed IMC-PID design of reduced order model achieves good dynamic response and robustness against load disturbance with the original high order system. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Non-integer viscoelastic constitutive law to model soft biological tissues to in-vivo indentation.

    PubMed

    Demirci, Nagehan; Tönük, Ergin

    2014-01-01

    During the last decades, derivatives and integrals of non-integer orders are being more commonly used for the description of constitutive behavior of various viscoelastic materials including soft biological tissues. Compared to integer order constitutive relations, non-integer order viscoelastic material models of soft biological tissues are capable of capturing a wider range of viscoelastic behavior obtained from experiments. Although integer order models may yield comparably accurate results, non-integer order material models have less number of parameters to be identified in addition to description of an intermediate material that can monotonically and continuously be adjusted in between an ideal elastic solid and an ideal viscous fluid. In this work, starting with some preliminaries on non-integer (fractional) calculus, the "spring-pot", (intermediate mechanical element between a solid and a fluid), non-integer order three element (Zener) solid model, finally a user-defined large strain non-integer order viscoelastic constitutive model was constructed to be used in finite element simulations. Using the constitutive equation developed, by utilizing inverse finite element method and in vivo indentation experiments, soft tissue material identification was performed. The results indicate that material coefficients obtained from relaxation experiments, when optimized with creep experimental data could simulate relaxation, creep and cyclic loading and unloading experiments accurately. Non-integer calculus viscoelastic constitutive models, having physical interpretation and modeling experimental data accurately is a good alternative to classical phenomenological viscoelastic constitutive equations.

  19. Under-reporting of pelvic inflammatory disease in Hawaii: a comparison of state surveillance and hospitalization data.

    PubMed

    Pacheco, Misty; Sentell, Tetine; Katz, Alan R

    2014-04-01

    Hawaii is one of only 19 states for which pelvic inflammatory disease (PID) is a mandated notifiable disease. In order to assess the completeness of PID reporting, we compared the number of hospitalized PID cases in the state of Hawaii with the total number of PID cases reported to the Hawaii State Department of Health surveillance system from 2007 through 2010. While 828 unique PID cases were diagnosed in Hawaii hospitals, only 240 unique PID cases were reported through the state's surveillance system. Severe PID underreporting was seen despite mandatory reporting laws.

  20. A novel interval type-2 fractional order fuzzy PID controller: Design, performance evaluation, and its optimal time domain tuning.

    PubMed

    Kumar, Anupam; Kumar, Vijay

    2017-05-01

    In this paper, a novel concept of an interval type-2 fractional order fuzzy PID (IT2FO-FPID) controller, which requires fractional order integrator and fractional order differentiator, is proposed. The incorporation of Takagi-Sugeno-Kang (TSK) type interval type-2 fuzzy logic controller (IT2FLC) with fractional controller of PID-type is investigated for time response measure due to both unit step response and unit load disturbance. The resulting IT2FO-FPID controller is examined on different delayed linear and nonlinear benchmark plants followed by robustness analysis. In order to design this controller, fractional order integrator-differentiator operators are considered as design variables including input-output scaling factors. A new hybridized algorithm named as artificial bee colony-genetic algorithm (ABC-GA) is used to optimize the parameters of the controller while minimizing weighted sum of integral of time absolute error (ITAE) and integral of square of control output (ISCO). To assess the comparative performance of the IT2FO-FPID, authors compared it against existing controllers, i.e., interval type-2 fuzzy PID (IT2-FPID), type-1 fractional order fuzzy PID (T1FO-FPID), type-1 fuzzy PID (T1-FPID), and conventional PID controllers. Furthermore, to show the effectiveness of the proposed controller, the perturbed processes along with the larger dead time are tested. Moreover, the proposed controllers are also implemented on multi input multi output (MIMO), coupled, and highly complex nonlinear two-link robot manipulator system in presence of un-modeled dynamics. Finally, the simulation results explicitly indicate that the performance of the proposed IT2FO-FPID controller is superior to its conventional counterparts in most of the cases. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  1. A Novel Technique for Performing PID Susceptibility Screening during the Solar Cell Fabrication Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, Jaewon; Dahal, Som; Dauksher, Bill

    2016-11-21

    Various characterization techniques have historically been developed in order to screen potential induced degradation (PID)-susceptible cells, but those techniques require final solar cells. We present a new characterization technique for screening PID-susceptible cells during the cell fabrication process. Illuminated Lock-In Thermography (ILIT) was used to image PID shunting of the cell without metallization and clearly showed PID-affected areas. PID-susceptible cells can be screened by ILIT, and the sample structure can advantageously be simplified as long as the sample has the silicon nitride antireflection coating and an aluminum back surface field.

  2. Research on Potential Induced Degradation (PID) of PV Modules in Different Typical Climate Regions

    NASA Astrophysics Data System (ADS)

    Daoren, Gong; Yingnan, Chen; Gang, Sun; Wenjing, Wang; Zhenshuang, Ji

    2018-03-01

    Potential Induced Degradation (PID) is one of the most important factors effecting the performances of Photovoltaic (PV) modules and PV systems in recent years. In this paper the PID phenomena of the PV power plant in different typical climate regions were studied and some experimental PID simulations were carried out in order to find out the factors effecting the performance by PID. The results show that the typical PID phenomena are easy to occur in cells close to the border of the PV module. PID phenomena can appear in PV power plants under different climate conditions, but the effecting degrees on module performance are different depending on temperature, humidity and other parameters. We also find the maximum power would recover in some degree after positive-bias voltage duration.

  3. Bidirectional active control of structures with type-2 fuzzy PD and PID

    NASA Astrophysics Data System (ADS)

    Paul, Satyam; Yu, Wen; Li, Xiaoou

    2018-03-01

    Proportional-derivative and proportional-integral-derivative (PD/PID) controllers are popular algorithms in structure vibration control. In order to maintain minimum regulation error, the PD/PID control require big proportional and derivative gains. The control performances are not satisfied because of the big uncertainties in the buildings. In this paper, type-2 fuzzy system is applied to compensate the unknown uncertainties, and is combined with the PD/PID control. We prove the stability of these fuzzy PD and PID controllers. The sufficient conditions can be used for choosing the gains of PD/PID. The theory results are verified by a two-storey building prototype. The experimental results validate our analysis.

  4. Order and Value: Transitioning to Integers

    ERIC Educational Resources Information Center

    Bofferding, Laura

    2014-01-01

    As students progress from working with whole numbers to working with integers, they must wrestle with the big ideas of number values and order. Using objects to show positive quantities is easy, but no physical negative quantities exist. Therefore, when talking about integers, the author refers to number values instead of number quantities. The…

  5. Performance comparison of optimal fractional order hybrid fuzzy PID controllers for handling oscillatory fractional order processes with dead time.

    PubMed

    Das, Saptarshi; Pan, Indranil; Das, Shantanu

    2013-07-01

    Fuzzy logic based PID controllers have been studied in this paper, considering several combinations of hybrid controllers by grouping the proportional, integral and derivative actions with fuzzy inferencing in different forms. Fractional order (FO) rate of error signal and FO integral of control signal have been used in the design of a family of decomposed hybrid FO fuzzy PID controllers. The input and output scaling factors (SF) along with the integro-differential operators are tuned with real coded genetic algorithm (GA) to produce optimum closed loop performance by simultaneous consideration of the control loop error index and the control signal. Three different classes of fractional order oscillatory processes with various levels of relative dominance between time constant and time delay have been used to test the comparative merits of the proposed family of hybrid fractional order fuzzy PID controllers. Performance comparison of the different FO fuzzy PID controller structures has been done in terms of optimal set-point tracking, load disturbance rejection and minimal variation of manipulated variable or smaller actuator requirement etc. In addition, multi-objective Non-dominated Sorting Genetic Algorithm (NSGA-II) has been used to study the Pareto optimal trade-offs between the set point tracking and control signal, and the set point tracking and load disturbance performance for each of the controller structure to handle the three different types of processes. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Performance and robustness of optimal fractional fuzzy PID controllers for pitch control of a wind turbine using chaotic optimization algorithms.

    PubMed

    Asgharnia, Amirhossein; Shahnazi, Reza; Jamali, Ali

    2018-05-11

    The most studied controller for pitch control of wind turbines is proportional-integral-derivative (PID) controller. However, due to uncertainties in wind turbine modeling and wind speed profiles, the need for more effective controllers is inevitable. On the other hand, the parameters of PID controller usually are unknown and should be selected by the designer which is neither a straightforward task nor optimal. To cope with these drawbacks, in this paper, two advanced controllers called fuzzy PID (FPID) and fractional-order fuzzy PID (FOFPID) are proposed to improve the pitch control performance. Meanwhile, to find the parameters of the controllers the chaotic evolutionary optimization methods are used. Using evolutionary optimization methods not only gives us the unknown parameters of the controllers but also guarantees the optimality based on the chosen objective function. To improve the performance of the evolutionary algorithms chaotic maps are used. All the optimization procedures are applied to the 2-mass model of 5-MW wind turbine model. The proposed optimal controllers are validated using simulator FAST developed by NREL. Simulation results demonstrate that the FOFPID controller can reach to better performance and robustness while guaranteeing fewer fatigue damages in different wind speeds in comparison to FPID, fractional-order PID (FOPID) and gain-scheduling PID (GSPID) controllers. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  7. The Construct Validity of the Dutch Personality Inventory for DSM-5 Personality Disorders (PID-5) in a Clinical Sample.

    PubMed

    Bastiaens, Tim; Claes, Laurence; Smits, Dirk; De Clercq, Barbara; De Fruyt, Filip; Rossi, Gina; Vanwalleghem, Dominique; Vermote, Rudi; Lowyck, Benedicte; Claes, Stephan; De Hert, Marc

    2016-02-01

    The factor structure and the convergent validity of the Personality Inventory for DSM-5 (PID-5), a self-report questionnaire designed to measure personality pathology as advocated in the fifth edition, Section III of Diagnostic and Statistical Manual of Mental Disorders (DSM-5), are already demonstrated in general population samples, but need replication in clinical samples. In 240 Flemish inpatients, we examined the factor structure of the PID-5 by means of exploratory structural equation modeling. Additionally, we investigated differences in PID-5 higher order domain scores according to gender, age and educational level, and explored convergent and discriminant validity by relating the PID-5 with the Dimensional Assessment of Personality Pathology-Basic Questionnaire and by comparing PID-5 scores of inpatients with and without a DSM-IV categorical personality disorder diagnosis. Our results confirmed the original five-factor structure of the PID-5. The reliability and the convergent and discriminant validity of the PID-5 proved to be adequate. Implications for future research are discussed. © The Author(s) 2015.

  8. Research on intelligent algorithm of electro - hydraulic servo control system

    NASA Astrophysics Data System (ADS)

    Wang, Yannian; Zhao, Yuhui; Liu, Chengtao

    2017-09-01

    In order to adapt the nonlinear characteristics of the electro-hydraulic servo control system and the influence of complex interference in the industrial field, using a fuzzy PID switching learning algorithm is proposed and a fuzzy PID switching learning controller is designed and applied in the electro-hydraulic servo controller. The designed controller not only combines the advantages of the fuzzy control and PID control, but also introduces the learning algorithm into the switching function, which makes the learning of the three parameters in the switching function can avoid the instability of the system during the switching between the fuzzy control and PID control algorithms. It also makes the switch between these two control algorithm more smoother than that of the conventional fuzzy PID.

  9. Design of sewage treatment system by applying fuzzy adaptive PID controller

    NASA Astrophysics Data System (ADS)

    Jin, Liang-Ping; Li, Hong-Chan

    2013-03-01

    In the sewage treatment system, the dissolved oxygen concentration control, due to its nonlinear, time-varying, large time delay and uncertainty, is difficult to establish the exact mathematical model. While the conventional PID controller only works with good linear not far from its operating point, it is difficult to realize the system control when the operating point far off. In order to solve the above problems, the paper proposed a method which combine fuzzy control with PID methods and designed a fuzzy adaptive PID controller based on S7-300 PLC .It employs fuzzy inference method to achieve the online tuning for PID parameters. The control algorithm by simulation and practical application show that the system has stronger robustness and better adaptability.

  10. Digital PI-PD controller design for arbitrary order systems: Dominant pole placement approach.

    PubMed

    Dincel, Emre; Söylemez, Mehmet Turan

    2018-05-02

    In this paper, a digital PI-PD controller design method is proposed for arbitrary order systems with or without time-delay to achieve desired transient response in the closed-loop via dominant pole placement approach. The digital PI-PD controller design problem is solved by converting the original problem to the digital PID controller design problem. Firstly, parametrization of the digital PID controllers which assign dominant poles to desired location is done. After that the subset of digital PID controller parameters in which the remaining poles are located away from the dominant pole pair is found via Chebyshev polynomials. The obtained PID controller parameters are then transformed into the PI-PD controller parameters by considering the closed-loop controller zero and the design is completed. Success of the proposed design method is firstly demonstrated on an example transfer function and compared with the well-known PID controller methods from the literature through simulations. After that the design method is implemented on the fan and plate laboratory system in a real environment. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  11. The application of immune genetic algorithm in main steam temperature of PID control of BP network

    NASA Astrophysics Data System (ADS)

    Li, Han; Zhen-yu, Zhang

    In order to overcome the uncertainties, large delay, large inertia and nonlinear property of the main steam temperature controlled object in the power plant, a neural network intelligent PID control system based on immune genetic algorithm and BP neural network is designed. Using the immune genetic algorithm global search optimization ability and good convergence, optimize the weights of the neural network, meanwhile adjusting PID parameters using BP network. The simulation result shows that the system is superior to conventional PID control system in the control of quality and robustness.

  12. Two-degree-of-freedom fractional order-PID controllers design for fractional order processes with dead-time.

    PubMed

    Li, Mingjie; Zhou, Ping; Zhao, Zhicheng; Zhang, Jinggang

    2016-03-01

    Recently, fractional order (FO) processes with dead-time have attracted more and more attention of many researchers in control field, but FO-PID controllers design techniques available for the FO processes with dead-time suffer from lack of direct systematic approaches. In this paper, a simple design and parameters tuning approach of two-degree-of-freedom (2-DOF) FO-PID controller based on internal model control (IMC) is proposed for FO processes with dead-time, conventional one-degree-of-freedom control exhibited the shortcoming of coupling of robustness and dynamic response performance. 2-DOF control can overcome the above weakness which means it realizes decoupling of robustness and dynamic performance from each other. The adjustable parameter η2 of FO-PID controller is directly related to the robustness of closed-loop system, and the analytical expression is given between the maximum sensitivity specification Ms and parameters η2. In addition, according to the dynamic performance requirement of the practical system, the parameters η1 can also be selected easily. By approximating the dead-time term of the process model with the first-order Padé or Taylor series, the expressions for 2-DOF FO-PID controller parameters are derived for three classes of FO processes with dead-time. Moreover, compared with other methods, the proposed method is simple and easy to implement. Finally, the simulation results are given to illustrate the effectiveness of this method. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Reliability and validity of the personality inventory for DSM-5 (PID-5): predicting DSM-IV personality disorders and psychopathy in community-dwelling Italian adults.

    PubMed

    Fossati, Andrea; Krueger, Robert F; Markon, Kristian E; Borroni, Serena; Maffei, Cesare

    2013-12-01

    In order to assess the internal consistency, factor structure, and ability to recover DSM-IV personality disorders (PDs) of the Personality Inventory for DSM-5 (PID-5) scales, 710 Italian adult community dwelling volunteers were administered the Italian translation of the PID-5, as well as the Italian translation of the Personality Diagnostic Questionnaire-4+ (PDQ-4+). Cronbach's alpha values were >.70 for all PID-5 facet scales and greater than .90 for all PID-5 domain scales. Parallel analysis and confirmatory factor analysis supported the theoretical five-factor model of the PID-5 trait scales. Regression analyses showed that both PID-5 trait and domain scales explained a substantial amount of variance in the PDQ-4+ PD scales, with the exception of the Passive-Aggressive PD scale. When the PID-5 was administered to a second independent sample of 389 Italian adult community dwelling volunteers, the basic psychometric properties of the scale were replicated. In this second sample, the PID-5 trait and domain scales proved to be significant predictors of psychopathy measures. As a whole, the results of the present study support the hypothesis that the PID-5 is a reliable instrument which is able to recover DSM-IV PDs, as well as to capture personality pathology that is not included in the DSM-IV (namely, psychopathy).

  14. Mutation particle swarm optimization of the BP-PID controller for piezoelectric ceramics

    NASA Astrophysics Data System (ADS)

    Zheng, Huaqing; Jiang, Minlan

    2016-01-01

    PID control is the most common used method in industrial control because its structure is simple and it is easy to implement. PID controller has good control effect, now it has been widely used. However, PID method has a few limitations. The overshoot of the PID controller is very big. The adjustment time is long. When the parameters of controlled plant are changing over time, the parameters of controller could hardly change automatically to adjust to changing environment. Thus, it can't meet the demand of control quality in the process of controlling piezoelectric ceramic. In order to effectively control the piezoelectric ceramic and improve the control accuracy, this paper replaced the learning algorithm of the BP with the mutation particle swarm optimization algorithm(MPSO) on the process of the parameters setting of BP-PID. That designed a better self-adaptive controller which is combing the BP neural network based on mutation particle swarm optimization with the conventional PID control theory. This combination is called the MPSO-BP-PID. In the mechanism of the MPSO, the mutation operation is carried out with the fitness variance and the global best fitness value as the standard. That can overcome the precocious of the PSO and strengthen its global search ability. As a result, the MPSO-BP-PID can complete controlling the controlled plant with higher speed and accuracy. Therefore, the MPSO-BP-PID is applied to the piezoelectric ceramic. It can effectively overcome the hysteresis, nonlinearity of the piezoelectric ceramic. In the experiment, compared with BP-PID and PSO-BP-PID, it proved that MPSO is effective and the MPSO-BP-PID has stronger adaptability and robustness.

  15. Demonstrative fractional order - PID controller based DC motor drive on digital platform.

    PubMed

    Khubalkar, Swapnil W; Junghare, Anjali S; Aware, Mohan V; Chopade, Amit S; Das, Shantanu

    2017-09-21

    In industrial drives applications, fractional order controllers can exhibit phenomenal impact due to realization through digital implementation. Digital fractional order controllers have created wide scope as it possess the inherent advantages like robustness against the plant parameter variation. This paper provides brief design procedure of fractional order proportional-integral-derivative (FO-PID) controller through the indirect approach of approximation using constant phase technique. The new modified dynamic particle swarm optimization (IdPSO) technique is proposed to find controller parameters. The FO-PID controller is implemented using floating point digital signal processor. The building blocks are designed and assembled with all peripheral components for the 1.5kW industrial DC motor drive. The robust operation for parametric variation is ascertained by testing the controller with two separately excited DC motors with the same rating but different parameters. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Magnetic impurity effect on charge and magnetic order in doped La1.5Ca0.5CoO4

    NASA Astrophysics Data System (ADS)

    Horigane, K.; Hiraka, H.; Tomiyasu, K.; Ohoyama, K.; Louca, D.; Yamada, K.

    2012-02-01

    Neutron scattering experiments were performed on single crystals of magnetic impurity doped cobalt oxides La1.5Ca0.5CoO4 to characterize the charge and spin orders. We newly found contrasting impurity effects. Two types of magnetic peaks are observed at q = (0.5,0,L) with L = half-integer and integer in La1.5Ca0.5CoO4, while magnetic peak at L = half-integer (integer) was only observed in Mn (Fe)-substituted sample. Although Mn and Fe impurities degrade charge and magnetic order, Cr impurity stabilizes the ordering at x = 0.5. Based on the crystal structural analysis of Cr doped sample, we found that the excess oxygen and change of octahedron around Co3+ were realized in Cr doped sample.

  17. Non-fragile multivariable PID controller design via system augmentation

    NASA Astrophysics Data System (ADS)

    Liu, Jinrong; Lam, James; Shen, Mouquan; Shu, Zhan

    2017-07-01

    In this paper, the issue of designing non-fragile H∞ multivariable proportional-integral-derivative (PID) controllers with derivative filters is investigated. In order to obtain the controller gains, the original system is associated with an extended system such that the PID controller design can be formulated as a static output-feedback control problem. By taking the system augmentation approach, the conditions with slack matrices for solving the non-fragile H∞ multivariable PID controller gains are established. Based on the results, linear matrix inequality -based iterative algorithms are provided to compute the controller gains. Simulations are conducted to verify the effectiveness of the proposed approaches.

  18. [Research on fuzzy proportional-integral-derivative control of master-slave minimally invasive operation robot driver].

    PubMed

    Zhao, Ximei; Ren, Chengyi; Liu, Hao; Li, Haogyi

    2014-12-01

    Robotic catheter minimally invasive operation requires that the driver control system has the advantages of quick response, strong anti-jamming and real-time tracking of target trajectory. Since the catheter parameters of itself and movement environment and other factors continuously change, when the driver is controlled using traditional proportional-integral-derivative (PID), the controller gain becomes fixed once the PID parameters are set. It can not change with the change of the parameters of the object and environmental disturbance so that its change affects the position tracking accuracy, and may bring a large overshoot endangering patients' vessel. Therefore, this paper adopts fuzzy PID control method to adjust PID gain parameters in the tracking process in order to improve the system anti-interference ability, dynamic performance and tracking accuracy. The simulation results showed that the fuzzy PID control method had a fast tracking performance and a strong robustness. Compared with those of traditional PID control, the feasibility and practicability of fuzzy PID control are verified in a robotic catheter minimally invasive operation.

  19. LMI designmethod for networked-based PID control

    NASA Astrophysics Data System (ADS)

    Souza, Fernando de Oliveira; Mozelli, Leonardo Amaral; de Oliveira, Maurício Carvalho; Palhares, Reinaldo Martinez

    2016-10-01

    In this paper, we propose a methodology for the design of networked PID controllers for second-order delayed processes using linear matrix inequalities. The proposed procedure takes into account time-varying delay on the plant, time-varying delays induced by the network and packed dropouts. The design is carried on entirely using a continuous-time model of the closed-loop system where time-varying delays are used to represent sampling and holding occurring in a discrete-time digital PID controller.

  20. Optimization of PID Parameters Utilizing Variable Weight Grey-Taguchi Method and Particle Swarm Optimization

    NASA Astrophysics Data System (ADS)

    Azmi, Nur Iffah Mohamed; Arifin Mat Piah, Kamal; Yusoff, Wan Azhar Wan; Romlay, Fadhlur Rahman Mohd

    2018-03-01

    Controller that uses PID parameters requires a good tuning method in order to improve the control system performance. Tuning PID control method is divided into two namely the classical methods and the methods of artificial intelligence. Particle swarm optimization algorithm (PSO) is one of the artificial intelligence methods. Previously, researchers had integrated PSO algorithms in the PID parameter tuning process. This research aims to improve the PSO-PID tuning algorithms by integrating the tuning process with the Variable Weight Grey- Taguchi Design of Experiment (DOE) method. This is done by conducting the DOE on the two PSO optimizing parameters: the particle velocity limit and the weight distribution factor. Computer simulations and physical experiments were conducted by using the proposed PSO- PID with the Variable Weight Grey-Taguchi DOE and the classical Ziegler-Nichols methods. They are implemented on the hydraulic positioning system. Simulation results show that the proposed PSO-PID with the Variable Weight Grey-Taguchi DOE has reduced the rise time by 48.13% and settling time by 48.57% compared to the Ziegler-Nichols method. Furthermore, the physical experiment results also show that the proposed PSO-PID with the Variable Weight Grey-Taguchi DOE tuning method responds better than Ziegler-Nichols tuning. In conclusion, this research has improved the PSO-PID parameter by applying the PSO-PID algorithm together with the Variable Weight Grey-Taguchi DOE method as a tuning method in the hydraulic positioning system.

  1. Solution to automatic generation control problem using firefly algorithm optimized I(λ)D(µ) controller.

    PubMed

    Debbarma, Sanjoy; Saikia, Lalit Chandra; Sinha, Nidul

    2014-03-01

    Present work focused on automatic generation control (AGC) of a three unequal area thermal systems considering reheat turbines and appropriate generation rate constraints (GRC). A fractional order (FO) controller named as I(λ)D(µ) controller based on crone approximation is proposed for the first time as an appropriate technique to solve the multi-area AGC problem in power systems. A recently developed metaheuristic algorithm known as firefly algorithm (FA) is used for the simultaneous optimization of the gains and other parameters such as order of integrator (λ) and differentiator (μ) of I(λ)D(µ) controller and governor speed regulation parameters (R). The dynamic responses corresponding to optimized I(λ)D(µ) controller gains, λ, μ, and R are compared with that of classical integer order (IO) controllers such as I, PI and PID controllers. Simulation results show that the proposed I(λ)D(µ) controller provides more improved dynamic responses and outperforms the IO based classical controllers. Further, sensitivity analysis confirms the robustness of the so optimized I(λ)D(µ) controller to wide changes in system loading conditions and size and position of SLP. Proposed controller is also found to have performed well as compared to IO based controllers when SLP takes place simultaneously in any two areas or all the areas. Robustness of the proposed I(λ)D(µ) controller is also tested against system parameter variations. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Reliability, Factor Structure, and Associations With Measures of Problem Relationship and Behavior of the Personality Inventory for DSM-5 in a Sample of Italian Community-Dwelling Adolescents.

    PubMed

    Somma, Antonella; Borroni, Serena; Maffei, Cesare; Giarolli, Laura E; Markon, Kristian E; Krueger, Robert F; Fossati, Andrea

    2017-10-01

    In order to assess the reliability, factorial validity, and criterion validity of the Personality Inventory for DSM-5 (PID-5) among adolescents, 1,264 Italian high school students were administered the PID-5. Participants were also administered the Questionnaire on Relationships and Substance Use as a criterion measure. In the full sample, McDonald's ω values were adequate for the PID-5 scales (median ω = .85, SD = .06), except for Suspiciousness. However, all PID-5 scales showed average inter-item correlation values in the .20-.55 range. Exploratory structural equation modeling analyses provided moderate support for the a priori model of PID-5 trait scales. Ordinal logistic regression analyses showed that selected PID-5 trait scales predicted a significant, albeit moderate (Cox & Snell R 2 values ranged from .08 to .15, all ps < .001) amount of variance in Questionnaire on Relationships and Substance Use variables.

  3. Research on Environmental Adjustment of Cloud Ranch Based on BP Neural Network PID Control

    NASA Astrophysics Data System (ADS)

    Ren, Jinzhi; Xiang, Wei; Zhao, Lin; Wu, Jianbo; Huang, Lianzhen; Tu, Qinggang; Zhao, Heming

    2018-01-01

    In order to make the intelligent ranch management mode replace the traditional artificial one gradually, this paper proposes a pasture environment control system based on cloud server, and puts forward the PID control algorithm based on BP neural network to control temperature and humidity better in the pasture environment. First, to model the temperature and humidity (controlled object) of the pasture, we can get the transfer function. Then the traditional PID control algorithm and the PID one based on BP neural network are applied to the transfer function. The obtained step tracking curves can be seen that the PID controller based on BP neural network has obvious superiority in adjusting time and error, etc. This algorithm, calculating reasonable control parameters of the temperature and humidity to control environment, can be better used in the cloud service platform.

  4. Active vibration and noise control of vibro-acoustic system by using PID controller

    NASA Astrophysics Data System (ADS)

    Li, Yunlong; Wang, Xiaojun; Huang, Ren; Qiu, Zhiping

    2015-07-01

    Active control simulation of the acoustic and vibration response of a vibro-acoustic cavity of an airplane based on a PID controller is presented. A full numerical vibro-acoustic model is developed by using an Eulerian model, which is a coupled model based on the finite element formulation. The reduced order model, which is used to design the closed-loop control system, is obtained by the combination of modal expansion and variable substitution. Some physical experiments are made to validate and update the full-order and the reduced-order numerical models. Optimization of the actuator placement is employed in order to get an effective closed-loop control system. For the controller design, an iterative method is used to determine the optimal parameters of the PID controller. The process is illustrated by the design of an active noise and vibration control system for a cavity structure. The numerical and experimental results show that a PID-based active control system can effectively suppress the noise inside the cavity using a sound pressure signal as the controller input. It is also possible to control the noise by suppressing the vibration of the structure using the structural displacement signal as the controller input. For an airplane cavity structure, considering the issue of space-saving, the latter is more suitable.

  5. Design and implementation of EP-based PID controller for chaos synchronization of Rikitake circuit systems.

    PubMed

    Hou, Yi-You

    2017-09-01

    This article addresses an evolutionary programming (EP) algorithm technique-based and proportional-integral-derivative (PID) control methods are established to guarantee synchronization of the master and slave Rikitake chaotic systems. For PID synchronous control, the evolutionary programming (EP) algorithm is used to find the optimal PID controller parameters k p , k i , k d by integrated absolute error (IAE) method for the convergence conditions. In order to verify the system performance, the basic electronic components containing operational amplifiers (OPAs), resistors, and capacitors are used to implement the proposed chaotic Rikitake systems. Finally, the experimental results validate the proposed Rikitake chaotic synchronization approach. Copyright © 2017. Published by Elsevier Ltd.

  6. Data Driven Synthesis of Three Term Digital Controllers

    NASA Astrophysics Data System (ADS)

    Keel, Lee H.; Mitra, Sandipan; Bhattacharyya, Shankar P.

    This paper presents a method for digital PID and first order controller synthesis based on frequency domain data alone. The techniques given here first determine all stabilizing controllers from measurement data. In both PID and first order controller cases, the only information required are frequency domain data (Nyquist-Bode data) and the number of open-loop RHP poles. Specifically no identification of the plant model is required. Examples are given for illustration.

  7. Stabilization of an inverted pendulum-cart system by fractional PI-state feedback.

    PubMed

    Bettayeb, M; Boussalem, C; Mansouri, R; Al-Saggaf, U M

    2014-03-01

    This paper deals with pole placement PI-state feedback controller design to control an integer order system. The fractional aspect of the control law is introduced by a dynamic state feedback as u(t)=K(p)x(t)+K(I)I(α)(x(t)). The closed loop characteristic polynomial is thus fractional for which the roots are complex to calculate. The proposed method allows us to decompose this polynomial into a first order fractional polynomial and an integer order polynomial of order n-1 (n being the order of the integer system). This new stabilization control algorithm is applied for an inverted pendulum-cart test-bed, and the effectiveness and robustness of the proposed control are examined by experiments. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  8. A time series model: First-order integer-valued autoregressive (INAR(1))

    NASA Astrophysics Data System (ADS)

    Simarmata, D. M.; Novkaniza, F.; Widyaningsih, Y.

    2017-07-01

    Nonnegative integer-valued time series arises in many applications. A time series model: first-order Integer-valued AutoRegressive (INAR(1)) is constructed by binomial thinning operator to model nonnegative integer-valued time series. INAR (1) depends on one period from the process before. The parameter of the model can be estimated by Conditional Least Squares (CLS). Specification of INAR(1) is following the specification of (AR(1)). Forecasting in INAR(1) uses median or Bayesian forecasting methodology. Median forecasting methodology obtains integer s, which is cumulative density function (CDF) until s, is more than or equal to 0.5. Bayesian forecasting methodology forecasts h-step-ahead of generating the parameter of the model and parameter of innovation term using Adaptive Rejection Metropolis Sampling within Gibbs sampling (ARMS), then finding the least integer s, where CDF until s is more than or equal to u . u is a value taken from the Uniform(0,1) distribution. INAR(1) is applied on pneumonia case in Penjaringan, Jakarta Utara, January 2008 until April 2016 monthly.

  9. Design of a self-adaptive fuzzy PID controller for piezoelectric ceramics micro-displacement system

    NASA Astrophysics Data System (ADS)

    Zhang, Shuang; Zhong, Yuning; Xu, Zhongbao

    2008-12-01

    In order to improve control precision of the piezoelectric ceramics (PZT) micro-displacement system, a self-adaptive fuzzy Proportional Integration Differential (PID) controller is designed based on the traditional digital PID controller combining with fuzzy control. The arithmetic gives a fuzzy control rule table with the fuzzy control rule and fuzzy reasoning, through this table, the PID parameters can be adjusted online in real time control. Furthermore, the automatic selective control is achieved according to the change of the error. The controller combines the good dynamic capability of the fuzzy control and the high stable precision of the PID control, adopts the method of using fuzzy control and PID control in different segments of time. In the initial and middle stage of the transition process of system, that is, when the error is larger than the value, fuzzy control is used to adjust control variable. It makes full use of the fast response of the fuzzy control. And when the error is smaller than the value, the system is about to be in the steady state, PID control is adopted to eliminate static error. The problems of PZT existing in the field of precise positioning are overcome. The results of the experiments prove that the project is correct and practicable.

  10. Stabilization and analytical tuning rule of double-loop control scheme for unstable dead-time process

    NASA Astrophysics Data System (ADS)

    Ugon, B.; Nandong, J.; Zang, Z.

    2017-06-01

    The presence of unstable dead-time systems in process plants often leads to a daunting challenge in the design of standard PID controllers, which are not only intended to provide close-loop stability but also to give good performance-robustness overall. In this paper, we conduct stability analysis on a double-loop control scheme based on the Routh-Hurwitz stability criteria. We propose to use this unstable double-loop control scheme which employs two P/PID controllers to control first-order or second-order unstable dead-time processes typically found in process industries. Based on the Routh-Hurwitz stability necessary and sufficient criteria, we establish several stability regions which enclose within them the P/PID parameter values that guarantee close-loop stability of the double-loop control scheme. A systematic tuning rule is developed for the purpose of obtaining the optimal P/PID parameter values within the established regions. The effectiveness of the proposed tuning rule is demonstrated using several numerical examples and the result are compared with some well-established tuning methods reported in the literature.

  11. Scheduling algorithms for rapid imaging using agile Cubesat constellations

    NASA Astrophysics Data System (ADS)

    Nag, Sreeja; Li, Alan S.; Merrick, James H.

    2018-02-01

    Distributed Space Missions such as formation flight and constellations, are being recognized as important Earth Observation solutions to increase measurement samples over space and time. Cubesats are increasing in size (27U, ∼40 kg in development) with increasing capabilities to host imager payloads. Given the precise attitude control systems emerging in the commercial market, Cubesats now have the ability to slew and capture images within short notice. We propose a modular framework that combines orbital mechanics, attitude control and scheduling optimization to plan the time-varying, full-body orientation of agile Cubesats in a constellation such that they maximize the number of observed images and observation time, within the constraints of Cubesat hardware specifications. The attitude control strategy combines bang-bang and PD control, with constraints such as power consumption, response time, and stability factored into the optimality computations and a possible extension to PID control to account for disturbances. Schedule optimization is performed using dynamic programming with two levels of heuristics, verified and improved upon using mixed integer linear programming. The automated scheduler is expected to run on ground station resources and the resultant schedules uplinked to the satellites for execution, however it can be adapted for onboard scheduling, contingent on Cubesat hardware and software upgrades. The framework is generalizable over small steerable spacecraft, sensor specifications, imaging objectives and regions of interest, and is demonstrated using multiple 20 kg satellites in Low Earth Orbit for two case studies - rapid imaging of Landsat's land and coastal images and extended imaging of global, warm water coral reefs. The proposed algorithm captures up to 161% more Landsat images than nadir-pointing sensors with the same field of view, on a 2-satellite constellation over a 12-h simulation. Integer programming was able to verify that optimality of the dynamic programming solution for single satellites was within 10%, and find up to 5% more optimal solutions. The optimality gap for constellations was found to be 22% at worst, but the dynamic programming schedules were found at nearly four orders of magnitude better computational speed than integer programming. The algorithm can include cloud cover predictions, ground downlink windows or any other spatial, temporal or angular constraints into the orbital module and be integrated into planning tools for agile constellations.

  12. Fast Integer Ambiguity Resolution for GPS Attitude Determination

    NASA Technical Reports Server (NTRS)

    Lightsey, E. Glenn; Crassidis, John L.; Markley, F. Landis

    1999-01-01

    In this paper, a new algorithm for GPS (Global Positioning System) integer ambiguity resolution is shown. The algorithm first incorporates an instantaneous (static) integer search to significantly reduce the search space using a geometric inequality. Then a batch-type loss function is used to check the remaining integers in order to determine the optimal integer. This batch function represents the GPS sightline vectors in the body frame as the sum of two vectors, one depending on the phase measurements and the other on the unknown integers. The new algorithm has several advantages: it does not require an a-priori estimate of the vehicle's attitude; it provides an inherent integrity check using a covariance-type expression; and it can resolve the integers even when coplanar baselines exist. The performance of the new algorithm is tested on a dynamic hardware simulator.

  13. Effects of a PID Control System on Electromagnetic Fields in an nEDM Experiment

    NASA Astrophysics Data System (ADS)

    Molina, Daniel

    2017-09-01

    The Kellogg Radiation Laboratory is currently testing a prototype for an experiment that hopes to identify the electric dipole moment of the neutron. As part of this testing, we have developed a PID (proportional, integral, derivative) feedback system that uses large coils to fix the value of local external magnetic fields, up to linear gradients. PID algorithms compare the current value to a set-point and use the integral and derivative of the field with respect to the set-point to maintain constant fields. We have also developed a method for zeroing linear gradients within the experimental apparatus. In order to determine the performance of the PID algorithm, measurements of both the internal and external fields were obtained with and without the algorithm running, and these results were compared for noise and time stability. We have seen that the PID algorithm can reduce the effect of disturbance to the field by a factor of 10.

  14. Investigating PID shunting in polycrystalline silicon modules via multiscale, multitechnique characterization

    DOE PAGES

    Harvey, Steven P.; Moseley, John; Norman, Andrew; ...

    2018-02-27

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis.more » By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.« less

  15. Reliability and clinical usefulness of the personality inventory for DSM-5 in clinically referred adolescents: A preliminary report in a sample of Italian inpatients.

    PubMed

    Somma, Antonella; Fossati, Andrea; Terrinoni, Arianna; Williams, Riccardo; Ardizzone, Ignazio; Fantini, Fiorella; Borroni, Serena; Krueger, Robert F; Markon, Kristian E; Ferrara, Mauro

    2016-10-01

    The DSM-5 Alternative Model of Personality Disorders (AMPD) provides the opportunity to integrate the needed developmental perspective in the assessment of personality pathology. Based on this model, Krueger and colleagues (2012) developed the Personality Inventory for DSM-5 (PID-5), which operationalizes the proposed DSM-5 traits. Eighty-five consecutively admitted Italian adolescent inpatients were administered the Italian translation of the PID-5, in order to obtain preliminary data on PID-5 reliability and clinical usefulness in clinically referred adolescents. With the possible exception of the PID-5 Suspiciousness scale, all other PID-5 scales evidenced adequate internal consistency reliability (i.e., Cronbach's α values of at least .70, most being greater than .80). Our data seemed to yield at least partial support for the construct validity of the PID-5 scales also in clinical adolescents, at least in terms of patterns of associations with dimensionally assessed DSM-5 Section II PDs that were also included in the DSM-5 AMPD (excluding Antisocial PD because of the participants' minor age). Finally, our data suggested that the clinical usefulness of the PID-5 in adolescent inpatients may extend beyond PDs to profiling adolescents at risk for life-threatening suicide attempts. In particular, PID-5 Depressivity, Anhedonia, and Submissiveness trait scales were significantly associated with adolescents' history of life-threatening suicide attempts, even after controlling for a number of other variables, including mood disorder diagnosis. As a whole, our study may provide interesting, albeit preliminary data as to the clinical usefulness of PID-5 in the assessment of adolescent inpatients. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. PID feedback controller used as a tactical asset allocation technique: The G.A.M. model

    NASA Astrophysics Data System (ADS)

    Gandolfi, G.; Sabatini, A.; Rossolini, M.

    2007-09-01

    The objective of this paper is to illustrate a tactical asset allocation technique utilizing the PID controller. The proportional-integral-derivative (PID) controller is widely applied in most industrial processes; it has been successfully used for over 50 years and it is used by more than 95% of the plants processes. It is a robust and easily understood algorithm that can provide excellent control performance in spite of the diverse dynamic characteristics of the process plant. In finance, the process plant, controlled by the PID controller, can be represented by financial market assets forming a portfolio. More specifically, in the present work, the plant is represented by a risk-adjusted return variable. Money and portfolio managers’ main target is to achieve a relevant risk-adjusted return in their managing activities. In literature and in the financial industry business, numerous kinds of return/risk ratios are commonly studied and used. The aim of this work is to perform a tactical asset allocation technique consisting in the optimization of risk adjusted return by means of asset allocation methodologies based on the PID model-free feedback control modeling procedure. The process plant does not need to be mathematically modeled: the PID control action lies in altering the portfolio asset weights, according to the PID algorithm and its parameters, Ziegler-and-Nichols-tuned, in order to approach the desired portfolio risk-adjusted return efficiently.

  17. An adaptive PID like controller using mix locally recurrent neural network for robotic manipulator with variable payload.

    PubMed

    Sharma, Richa; Kumar, Vikas; Gaur, Prerna; Mittal, A P

    2016-05-01

    Being complex, non-linear and coupled system, the robotic manipulator cannot be effectively controlled using classical proportional-integral-derivative (PID) controller. To enhance the effectiveness of the conventional PID controller for the nonlinear and uncertain systems, gains of the PID controller should be conservatively tuned and should adapt to the process parameter variations. In this work, a mix locally recurrent neural network (MLRNN) architecture is investigated to mimic a conventional PID controller which consists of at most three hidden nodes which act as proportional, integral and derivative node. The gains of the mix locally recurrent neural network based PID (MLRNNPID) controller scheme are initialized with a newly developed cuckoo search algorithm (CSA) based optimization method rather than assuming randomly. A sequential learning based least square algorithm is then investigated for the on-line adaptation of the gains of MLRNNPID controller. The performance of the proposed controller scheme is tested against the plant parameters uncertainties and external disturbances for both links of the two link robotic manipulator with variable payload (TL-RMWVP). The stability of the proposed controller is analyzed using Lyapunov stability criteria. A performance comparison is carried out among MLRNNPID controller, CSA optimized NNPID (OPTNNPID) controller and CSA optimized conventional PID (OPTPID) controller in order to establish the effectiveness of the MLRNNPID controller. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Physical Applications of a Simple Approximation of Bessel Functions of Integer Order

    ERIC Educational Resources Information Center

    Barsan, V.; Cojocaru, S.

    2007-01-01

    Applications of a simple approximation of Bessel functions of integer order, in terms of trigonometric functions, are discussed for several examples from electromagnetism and optics. The method may be applied in the intermediate regime, bridging the "small values regime" and the "asymptotic" one, and covering, in this way, an area of great…

  19. Particle identification in ALICE: a Bayesian approach

    NASA Astrophysics Data System (ADS)

    Adam, J.; Adamová, D.; Aggarwal, M. M.; Aglieri Rinella, G.; Agnello, M.; Agrawal, N.; Ahammed, Z.; Ahmad, S.; Ahn, S. U.; Aiola, S.; Akindinov, A.; Alam, S. N.; Albuquerque, D. S. D.; Aleksandrov, D.; Alessandro, B.; Alexandre, D.; Alfaro Molina, R.; Alici, A.; Alkin, A.; Almaraz, J. R. M.; Alme, J.; Alt, T.; Altinpinar, S.; Altsybeev, I.; Alves Garcia Prado, C.; Andrei, C.; Andronic, A.; Anguelov, V.; Antičić, T.; Antinori, F.; Antonioli, P.; Aphecetche, L.; Appelshäuser, H.; Arcelli, S.; Arnaldi, R.; Arnold, O. W.; Arsene, I. C.; Arslandok, M.; Audurier, B.; Augustinus, A.; Averbeck, R.; Azmi, M. D.; Badalà, A.; Baek, Y. W.; Bagnasco, S.; Bailhache, R.; Bala, R.; Balasubramanian, S.; Baldisseri, A.; Baral, R. C.; Barbano, A. M.; Barbera, R.; Barile, F.; Barnaföldi, G. G.; Barnby, L. S.; Barret, V.; Bartalini, P.; Barth, K.; Bartke, J.; Bartsch, E.; Basile, M.; Bastid, N.; Basu, S.; Bathen, B.; Batigne, G.; Batista Camejo, A.; Batyunya, B.; Batzing, P. C.; Bearden, I. G.; Beck, H.; Bedda, C.; Behera, N. K.; Belikov, I.; Bellini, F.; Bello Martinez, H.; Bellwied, R.; Belmont, R.; Belmont-Moreno, E.; Belyaev, V.; Benacek, P.; Bencedi, G.; Beole, S.; Berceanu, I.; Bercuci, A.; Berdnikov, Y.; Berenyi, D.; Bertens, R. A.; Berzano, D.; Betev, L.; Bhasin, A.; Bhat, I. R.; Bhati, A. K.; Bhattacharjee, B.; Bhom, J.; Bianchi, L.; Bianchi, N.; Bianchin, C.; Bielčík, J.; Bielčíková, J.; Bilandzic, A.; Biro, G.; Biswas, R.; Biswas, S.; Bjelogrlic, S.; Blair, J. T.; Blau, D.; Blume, C.; Bock, F.; Bogdanov, A.; Bøggild, H.; Boldizsár, L.; Bombara, M.; Book, J.; Borel, H.; Borissov, A.; Borri, M.; Bossú, F.; Botta, E.; Bourjau, C.; Braun-Munzinger, P.; Bregant, M.; Breitner, T.; Broker, T. A.; Browning, T. A.; Broz, M.; Brucken, E. J.; Bruna, E.; Bruno, G. E.; Budnikov, D.; Buesching, H.; Bufalino, S.; Buncic, P.; Busch, O.; Buthelezi, Z.; Butt, J. B.; Buxton, J. T.; Cabala, J.; Caffarri, D.; Cai, X.; Caines, H.; Calero Diaz, L.; Caliva, A.; Calvo Villar, E.; Camerini, P.; Carena, F.; Carena, W.; Carnesecchi, F.; Castillo Castellanos, J.; Castro, A. J.; Casula, E. A. R.; Ceballos Sanchez, C.; Cepila, J.; Cerello, P.; Cerkala, J.; Chang, B.; Chapeland, S.; Chartier, M.; Charvet, J. L.; Chattopadhyay, S.; Chattopadhyay, S.; Chauvin, A.; Chelnokov, V.; Cherney, M.; Cheshkov, C.; Cheynis, B.; Chibante Barroso, V.; Chinellato, D. D.; Cho, S.; Chochula, P.; Choi, K.; Chojnacki, M.; Choudhury, S.; Christakoglou, P.; Christensen, C. H.; Christiansen, P.; Chujo, T.; Chung, S. U.; Cicalo, C.; Cifarelli, L.; Cindolo, F.; Cleymans, J.; Colamaria, F.; Colella, D.; Collu, A.; Colocci, M.; Conesa Balbastre, G.; Conesa del Valle, Z.; Connors, M. E.; Contreras, J. G.; Cormier, T. M.; Corrales Morales, Y.; Cortés Maldonado, I.; Cortese, P.; Cosentino, M. R.; Costa, F.; Crochet, P.; Cruz Albino, R.; Cuautle, E.; Cunqueiro, L.; Dahms, T.; Dainese, A.; Danisch, M. C.; Danu, A.; Das, D.; Das, I.; Das, S.; Dash, A.; Dash, S.; De, S.; De Caro, A.; de Cataldo, G.; de Conti, C.; de Cuveland, J.; De Falco, A.; De Gruttola, D.; De Marco, N.; De Pasquale, S.; Deisting, A.; Deloff, A.; Dénes, E.; Deplano, C.; Dhankher, P.; Di Bari, D.; Di Mauro, A.; Di Nezza, P.; Diaz Corchero, M. A.; Dietel, T.; Dillenseger, P.; Divià, R.; Djuvsland, Ø.; Dobrin, A.; Domenicis Gimenez, D.; Dönigus, B.; Dordic, O.; Drozhzhova, T.; Dubey, A. K.; Dubla, A.; Ducroux, L.; Dupieux, P.; Ehlers, R. J.; Elia, D.; Endress, E.; Engel, H.; Epple, E.; Erazmus, B.; Erdemir, I.; Erhardt, F.; Espagnon, B.; Estienne, M.; Esumi, S.; Eum, J.; Evans, D.; Evdokimov, S.; Eyyubova, G.; Fabbietti, L.; Fabris, D.; Faivre, J.; Fantoni, A.; Fasel, M.; Feldkamp, L.; Feliciello, A.; Feofilov, G.; Ferencei, J.; Fernández Téllez, A.; Ferreiro, E. G.; Ferretti, A.; Festanti, A.; Feuillard, V. J. G.; Figiel, J.; Figueredo, M. A. S.; Filchagin, S.; Finogeev, D.; Fionda, F. M.; Fiore, E. M.; Fleck, M. G.; Floris, M.; Foertsch, S.; Foka, P.; Fokin, S.; Fragiacomo, E.; Francescon, A.; Frankenfeld, U.; Fronze, G. G.; Fuchs, U.; Furget, C.; Furs, A.; Fusco Girard, M.; Gaardhøje, J. J.; Gagliardi, M.; Gago, A. M.; Gallio, M.; Gangadharan, D. R.; Ganoti, P.; Gao, C.; Garabatos, C.; Garcia-Solis, E.; Gargiulo, C.; Gasik, P.; Gauger, E. F.; Germain, M.; Gheata, A.; Gheata, M.; Ghosh, P.; Ghosh, S. K.; Gianotti, P.; Giubellino, P.; Giubilato, P.; Gladysz-Dziadus, E.; Glässel, P.; Goméz Coral, D. M.; Gomez Ramirez, A.; Gonzalez, A. S.; Gonzalez, V.; González-Zamora, P.; Gorbunov, S.; Görlich, L.; Gotovac, S.; Grabski, V.; Grachov, O. A.; Graczykowski, L. K.; Graham, K. L.; Grelli, A.; Grigoras, A.; Grigoras, C.; Grigoriev, V.; Grigoryan, A.; Grigoryan, S.; Grinyov, B.; Grion, N.; Gronefeld, J. M.; Grosse-Oetringhaus, J. F.; Grosso, R.; Guber, F.; Guernane, R.; Guerzoni, B.; Gulbrandsen, K.; Gunji, T.; Gupta, A.; Gupta, R.; Haake, R.; Haaland, Ø.; Hadjidakis, C.; Haiduc, M.; Hamagaki, H.; Hamar, G.; Hamon, J. C.; Harris, J. W.; Harton, A.; Hatzifotiadou, D.; Hayashi, S.; Heckel, S. T.; Hellbär, E.; Helstrup, H.; Herghelegiu, A.; Herrera Corral, G.; Hess, B. A.; Hetland, K. F.; Hillemanns, H.; Hippolyte, B.; Horak, D.; Hosokawa, R.; Hristov, P.; Humanic, T. J.; Hussain, N.; Hussain, T.; Hutter, D.; Hwang, D. S.; Ilkaev, R.; Inaba, M.; Incani, E.; Ippolitov, M.; Irfan, M.; Ivanov, M.; Ivanov, V.; Izucheev, V.; Jacazio, N.; Jacobs, P. M.; Jadhav, M. B.; Jadlovska, S.; Jadlovsky, J.; Jahnke, C.; Jakubowska, M. J.; Jang, H. J.; Janik, M. A.; Jayarathna, P. H. S. Y.; Jena, C.; Jena, S.; Jimenez Bustamante, R. T.; Jones, P. G.; Jusko, A.; Kalinak, P.; Kalweit, A.; Kamin, J.; Kang, J. H.; Kaplin, V.; Kar, S.; Karasu Uysal, A.; Karavichev, O.; Karavicheva, T.; Karayan, L.; Karpechev, E.; Kebschull, U.; Keidel, R.; Keijdener, D. L. D.; Keil, M.; Mohisin Khan, M.; Khan, P.; Khan, S. A.; Khanzadeev, A.; Kharlov, Y.; Kileng, B.; Kim, D. W.; Kim, D. J.; Kim, D.; Kim, H.; Kim, J. S.; Kim, M.; Kim, S.; Kim, T.; Kirsch, S.; Kisel, I.; Kiselev, S.; Kisiel, A.; Kiss, G.; Klay, J. L.; Klein, C.; Klein, J.; Klein-Bösing, C.; Klewin, S.; Kluge, A.; Knichel, M. L.; Knospe, A. G.; Kobdaj, C.; Kofarago, M.; Kollegger, T.; Kolojvari, A.; Kondratiev, V.; Kondratyeva, N.; Kondratyuk, E.; Konevskikh, A.; Kopcik, M.; Kostarakis, P.; Kour, M.; Kouzinopoulos, C.; Kovalenko, O.; Kovalenko, V.; Kowalski, M.; Koyithatta Meethaleveedu, G.; Králik, I.; Kravčáková, A.; Krivda, M.; Krizek, F.; Kryshen, E.; Krzewicki, M.; Kubera, A. M.; Kučera, V.; Kuhn, C.; Kuijer, P. G.; Kumar, A.; Kumar, J.; Kumar, L.; Kumar, S.; Kurashvili, P.; Kurepin, A.; Kurepin, A. B.; Kuryakin, A.; Kweon, M. J.; Kwon, Y.; La Pointe, S. L.; La Rocca, P.; Ladron de Guevara, P.; Lagana Fernandes, C.; Lakomov, I.; Langoy, R.; Lara, C.; Lardeux, A.; Lattuca, A.; Laudi, E.; Lea, R.; Leardini, L.; Lee, G. R.; Lee, S.; Lehas, F.; Lemmon, R. C.; Lenti, V.; Leogrande, E.; León Monzón, I.; León Vargas, H.; Leoncino, M.; Lévai, P.; Li, S.; Li, X.; Lien, J.; Lietava, R.; Lindal, S.; Lindenstruth, V.; Lippmann, C.; Lisa, M. A.; Ljunggren, H. M.; Lodato, D. F.; Loenne, P. I.; Loginov, V.; Loizides, C.; Lopez, X.; López Torres, E.; Lowe, A.; Luettig, P.; Lunardon, M.; Luparello, G.; Lutz, T. H.; Maevskaya, A.; Mager, M.; Mahajan, S.; Mahmood, S. M.; Maire, A.; Majka, R. D.; Malaev, M.; Maldonado Cervantes, I.; Malinina, L.; Mal'Kevich, D.; Malzacher, P.; Mamonov, A.; Manko, V.; Manso, F.; Manzari, V.; Marchisone, M.; Mareš, J.; Margagliotti, G. V.; Margotti, A.; Margutti, J.; Marín, A.; Markert, C.; Marquard, M.; Martin, N. A.; Martin Blanco, J.; Martinengo, P.; Martínez, M. I.; Martínez García, G.; Martinez Pedreira, M.; Mas, A.; Masciocchi, S.; Masera, M.; Masoni, A.; Mastroserio, A.; Matyja, A.; Mayer, C.; Mazer, J.; Mazzoni, M. A.; Mcdonald, D.; Meddi, F.; Melikyan, Y.; Menchaca-Rocha, A.; Meninno, E.; Mercado Pérez, J.; Meres, M.; Miake, Y.; Mieskolainen, M. M.; Mikhaylov, K.; Milano, L.; Milosevic, J.; Mischke, A.; Mishra, A. N.; Miśkowiec, D.; Mitra, J.; Mitu, C. M.; Mohammadi, N.; Mohanty, B.; Molnar, L.; Montaño Zetina, L.; Montes, E.; Moreira De Godoy, D. A.; Moreno, L. A. P.; Moretto, S.; Morreale, A.; Morsch, A.; Muccifora, V.; Mudnic, E.; Mühlheim, D.; Muhuri, S.; Mukherjee, M.; Mulligan, J. D.; Munhoz, M. G.; Munzer, R. H.; Murakami, H.; Murray, S.; Musa, L.; Musinsky, J.; Naik, B.; Nair, R.; Nandi, B. K.; Nania, R.; Nappi, E.; Naru, M. U.; Natal da Luz, H.; Nattrass, C.; Navarro, S. R.; Nayak, K.; Nayak, R.; Nayak, T. K.; Nazarenko, S.; Nedosekin, A.; Nellen, L.; Ng, F.; Nicassio, M.; Niculescu, M.; Niedziela, J.; Nielsen, B. S.; Nikolaev, S.; Nikulin, S.; Nikulin, V.; Noferini, F.; Nomokonov, P.; Nooren, G.; Noris, J. C. C.; Norman, J.; Nyanin, A.; Nystrand, J.; Oeschler, H.; Oh, S.; Oh, S. K.; Ohlson, A.; Okatan, A.; Okubo, T.; Olah, L.; Oleniacz, J.; Oliveira Da Silva, A. C.; Oliver, M. H.; Onderwaater, J.; Oppedisano, C.; Orava, R.; Oravec, M.; Ortiz Velasquez, A.; Oskarsson, A.; Otwinowski, J.; Oyama, K.; Ozdemir, M.; Pachmayer, Y.; Pagano, D.; Pagano, P.; Paić, G.; Pal, S. K.; Pan, J.; Pandey, A. K.; Papikyan, V.; Pappalardo, G. S.; Pareek, P.; Park, W. J.; Parmar, S.; Passfeld, A.; Paticchio, V.; Patra, R. N.; Paul, B.; Pei, H.; Peitzmann, T.; Pereira Da Costa, H.; Peresunko, D.; Pérez Lara, C. E.; Perez Lezama, E.; Peskov, V.; Pestov, Y.; Petráček, V.; Petrov, V.; Petrovici, M.; Petta, C.; Piano, S.; Pikna, M.; Pillot, P.; Pimentel, L. O. D. L.; Pinazza, O.; Pinsky, L.; Piyarathna, D. B.; Płoskoń, M.; Planinic, M.; Pluta, J.; Pochybova, S.; Podesta-Lerma, P. L. M.; Poghosyan, M. G.; Polichtchouk, B.; Poljak, N.; Poonsawat, W.; Pop, A.; Porteboeuf-Houssais, S.; Porter, J.; Pospisil, J.; Prasad, S. K.; Preghenella, R.; Prino, F.; Pruneau, C. A.; Pshenichnov, I.; Puccio, M.; Puddu, G.; Pujahari, P.; Punin, V.; Putschke, J.; Qvigstad, H.; Rachevski, A.; Raha, S.; Rajput, S.; Rak, J.; Rakotozafindrabe, A.; Ramello, L.; Rami, F.; Raniwala, R.; Raniwala, S.; Räsänen, S. S.; Rascanu, B. T.; Rathee, D.; Read, K. F.; Redlich, K.; Reed, R. J.; Rehman, A.; Reichelt, P.; Reidt, F.; Ren, X.; Renfordt, R.; Reolon, A. R.; Reshetin, A.; Reygers, K.; Riabov, V.; Ricci, R. A.; Richert, T.; Richter, M.; Riedler, P.; Riegler, W.; Riggi, F.; Ristea, C.; Rocco, E.; Rodríguez Cahuantzi, M.; Rodriguez Manso, A.; Røed, K.; Rogochaya, E.; Rohr, D.; Röhrich, D.; Ronchetti, F.; Ronflette, L.; Rosnet, P.; Rossi, A.; Roukoutakis, F.; Roy, A.; Roy, C.; Roy, P.; Rubio Montero, A. J.; Rui, R.; Russo, R.; Ryabinkin, E.; Ryabov, Y.; Rybicki, A.; Saarinen, S.; Sadhu, S.; Sadovsky, S.; Šafařík, K.; Sahlmuller, B.; Sahoo, P.; Sahoo, R.; Sahoo, S.; Sahu, P. K.; Saini, J.; Sakai, S.; Saleh, M. A.; Salzwedel, J.; Sambyal, S.; Samsonov, V.; Šándor, L.; Sandoval, A.; Sano, M.; Sarkar, D.; Sarkar, N.; Sarma, P.; Scapparone, E.; Scarlassara, F.; Schiaua, C.; Schicker, R.; Schmidt, C.; Schmidt, H. R.; Schuchmann, S.; Schukraft, J.; Schulc, M.; Schutz, Y.; Schwarz, K.; Schweda, K.; Scioli, G.; Scomparin, E.; Scott, R.; Šefčík, M.; Seger, J. E.; Sekiguchi, Y.; Sekihata, D.; Selyuzhenkov, I.; Senosi, K.; Senyukov, S.; Serradilla, E.; Sevcenco, A.; Shabanov, A.; Shabetai, A.; Shadura, O.; Shahoyan, R.; Shahzad, M. I.; Shangaraev, A.; Sharma, A.; Sharma, M.; Sharma, M.; Sharma, N.; Sheikh, A. I.; Shigaki, K.; Shou, Q.; Shtejer, K.; Sibiriak, Y.; Siddhanta, S.; Sielewicz, K. M.; Siemiarczuk, T.; Silvermyr, D.; Silvestre, C.; Simatovic, G.; Simonetti, G.; Singaraju, R.; Singh, R.; Singha, S.; Singhal, V.; Sinha, B. C.; Sinha, T.; Sitar, B.; Sitta, M.; Skaali, T. B.; Slupecki, M.; Smirnov, N.; Snellings, R. J. M.; Snellman, T. W.; Song, J.; Song, M.; Song, Z.; Soramel, F.; Sorensen, S.; Souza, R. D. de; Sozzi, F.; Spacek, M.; Spiriti, E.; Sputowska, I.; Spyropoulou-Stassinaki, M.; Stachel, J.; Stan, I.; Stankus, P.; Stenlund, E.; Steyn, G.; Stiller, J. H.; Stocco, D.; Strmen, P.; Suaide, A. A. P.; Sugitate, T.; Suire, C.; Suleymanov, M.; Suljic, M.; Sultanov, R.; Šumbera, M.; Sumowidagdo, S.; Szabo, A.; Szanto de Toledo, A.; Szarka, I.; Szczepankiewicz, A.; Szymanski, M.; Tabassam, U.; Takahashi, J.; Tambave, G. J.; Tanaka, N.; Tarhini, M.; Tariq, M.; Tarzila, M. G.; Tauro, A.; Tejeda Muñoz, G.; Telesca, A.; Terasaki, K.; Terrevoli, C.; Teyssier, B.; Thäder, J.; Thakur, D.; Thomas, D.; Tieulent, R.; Timmins, A. R.; Toia, A.; Trogolo, S.; Trombetta, G.; Trubnikov, V.; Trzaska, W. H.; Tsuji, T.; Tumkin, A.; Turrisi, R.; Tveter, T. S.; Ullaland, K.; Uras, A.; Usai, G. L.; Utrobicic, A.; Vala, M.; Valencia Palomo, L.; Vallero, S.; Van Der Maarel, J.; Van Hoorne, J. W.; van Leeuwen, M.; Vanat, T.; Vande Vyvre, P.; Varga, D.; Vargas, A.; Vargyas, M.; Varma, R.; Vasileiou, M.; Vasiliev, A.; Vauthier, A.; Vechernin, V.; Veen, A. M.; Veldhoen, M.; Velure, A.; Vercellin, E.; Vergara Limón, S.; Vernet, R.; Verweij, M.; Vickovic, L.; Viesti, G.; Viinikainen, J.; Vilakazi, Z.; Villalobos Baillie, O.; Villatoro Tello, A.; Vinogradov, A.; Vinogradov, L.; Vinogradov, Y.; Virgili, T.; Vislavicius, V.; Viyogi, Y. P.; Vodopyanov, A.; Völkl, M. A.; Voloshin, K.; Voloshin, S. A.; Volpe, G.; von Haller, B.; Vorobyev, I.; Vranic, D.; Vrláková, J.; Vulpescu, B.; Wagner, B.; Wagner, J.; Wang, H.; Wang, M.; Watanabe, D.; Watanabe, Y.; Weber, M.; Weber, S. G.; Weiser, D. F.; Wessels, J. P.; Westerhoff, U.; Whitehead, A. M.; Wiechula, J.; Wikne, J.; Wilk, G.; Wilkinson, J.; Williams, M. C. S.; Windelband, B.; Winn, M.; Yang, H.; Yang, P.; Yano, S.; Yasin, Z.; Yin, Z.; Yokoyama, H.; Yoo, I.-K.; Yoon, J. H.; Yurchenko, V.; Yushmanov, I.; Zaborowska, A.; Zaccolo, V.; Zaman, A.; Zampolli, C.; Zanoli, H. J. C.; Zaporozhets, S.; Zardoshti, N.; Zarochentsev, A.; Závada, P.; Zaviyalov, N.; Zbroszczyk, H.; Zgura, I. S.; Zhalov, M.; Zhang, H.; Zhang, X.; Zhang, Y.; Zhang, C.; Zhang, Z.; Zhao, C.; Zhigareva, N.; Zhou, D.; Zhou, Y.; Zhou, Z.; Zhu, H.; Zhu, J.; Zichichi, A.; Zimmermann, A.; Zimmermann, M. B.; Zinovjev, G.; Zyzak, M.

    2016-05-01

    We present a Bayesian approach to particle identification (PID) within the ALICE experiment. The aim is to more effectively combine the particle identification capabilities of its various detectors. After a brief explanation of the adopted methodology and formalism, the performance of the Bayesian PID approach for charged pions, kaons and protons in the central barrel of ALICE is studied. PID is performed via measurements of specific energy loss ( d E/d x) and time of flight. PID efficiencies and misidentification probabilities are extracted and compared with Monte Carlo simulations using high-purity samples of identified particles in the decay channels K0S → π-π+, φ→ K-K+, and Λ→ p π- in p-Pb collisions at √{s_{NN}}=5.02 TeV. In order to thoroughly assess the validity of the Bayesian approach, this methodology was used to obtain corrected pT spectra of pions, kaons, protons, and D0 mesons in pp collisions at √{s}=7 TeV. In all cases, the results using Bayesian PID were found to be consistent with previous measurements performed by ALICE using a standard PID approach. For the measurement of D0 → K-π+, it was found that a Bayesian PID approach gave a higher signal-to-background ratio and a similar or larger statistical significance when compared with standard PID selections, despite a reduced identification efficiency. Finally, we present an exploratory study of the measurement of Λc+ → p K-π+ in pp collisions at √{s}=7 TeV, using the Bayesian approach for the identification of its decay products.

  20. Multivariable PID controller design tuning using bat algorithm for activated sludge process

    NASA Astrophysics Data System (ADS)

    Atikah Nor’Azlan, Nur; Asmiza Selamat, Nur; Mat Yahya, Nafrizuan

    2018-04-01

    The designing of a multivariable PID control for multi input multi output is being concerned with this project by applying four multivariable PID control tuning which is Davison, Penttinen-Koivo, Maciejowski and Proposed Combined method. The determination of this study is to investigate the performance of selected optimization technique to tune the parameter of MPID controller. The selected optimization technique is Bat Algorithm (BA). All the MPID-BA tuning result will be compared and analyzed. Later, the best MPID-BA will be chosen in order to determine which techniques are better based on the system performances in terms of transient response.

  1. Quadrotor trajectory tracking using PID cascade control

    NASA Astrophysics Data System (ADS)

    Idres, M.; Mustapha, O.; Okasha, M.

    2017-12-01

    Quadrotors have been applied to collect information for traffic, weather monitoring, surveillance and aerial photography. In order to accomplish their mission, quadrotors have to follow specific trajectories. This paper presents proportional-integral-derivative (PID) cascade control of a quadrotor for path tracking problem when velocity and acceleration are small. It is based on near hover controller for small attitude angles. The integral of time-weighted absolute error (ITAE) criterion is used to determine the PID gains as a function of quadrotor modeling parameters. The controller is evaluated in three-dimensional environment in Simulink. Overall, the tracking performance is found to be excellent for small velocity condition.

  2. A Head-to-Head Comparison of the Personality Inventory for DSM-5 (PID-5) With the Personality Diagnostic Questionnaire-4 (PDQ-4) in Predicting the General Level of Personality Pathology Among Community Dwelling Subjects.

    PubMed

    Fossati, Andrea; Somma, Antonella; Borroni, Serena; Maffei, Cesare; Markon, Kristian E; Krueger, Robert F

    2016-02-01

    In order to evaluate if measures of DSM-5 Alternative PD Model domains predicted interview-based scores of general personality pathology when compared to self-report measures of DSM-IV Axis II/DSM-5 Section II PD criteria, 300 Italian community adults were administered the Iowa Personality Disorder Screen (IPDS) interview, the Personality Inventory for DSM-5 (PID-5), and the Personality Diagnostic Questionnaire-4+ (PDQ-4+). Multiple regression analyses showed that the five PID-5 domain scales collectively explained an adequate rate of the variance of the IPDS interview total score. This result was slightly lower than the amount of variance in the IPDS total score explained by the 10 PDQ-4+ scales. The PID-5 traits scales performed better than the PDQ-4+, although the difference was marginal. Hierarchical regression analyses revealed that the PID-5 domain and trait scales provided a moderate, but significant increase in the prediction of the general level of personality pathology above and beyond the PDQ-4+ scales.

  3. Primary immunodeficiency investigation in patients during and after hospitalization in a pediatric Intensive Care Unit

    PubMed Central

    Suavinho, Érica; de Nápolis, Ana Carolina R.; Segundo, Gesmar Rodrigues S.

    2014-01-01

    Objective: To analyze whether the patients with severe infections, admitted in the Pediatric Intensive Care Unit of the Hospital de Clínicas of the Universidade Federal de Uberlândia, underwent the active screening for primary immunodeficiencies (PID). Methods: Retrospective study that assessed the data records of patients with any severe infections admitted in the Pediatric Intensive Care Unit, covering a period from January 2011 to January 2012, in order to confirm if they performed an initial investigation for PID with blood count and immunoglobulin dosage. Results: In the studied period, 53 children were hospitalized with severe infections in the Pediatric Intensive Care Unit, and only in seven (13.2%) the initial investigation of PID was performed. Among these patients, 3/7 (42.8%) showed quantitative alterations in immunoglobulin G (IgG) levels, 1/7 (14.3%) had the diagnosis of cyclic neutropenia, and 1/7 (14.3%) presented thrombocytopenia and a final diagnosis of Wiskott-Aldrich syndrome. Therefore, the PID diagnosis was confirmed in 5/7 (71.4%) of the patients. Conclusions: The investigation of PID in patients with severe infections has not been routinely performed in the Pediatric Intensive Care Unit. Our findings suggest the necessity of performing PID investigation in this group of patients. PMID:24676187

  4. Evaluation of PD/PID controller for insulin control on blood glucose regulation in a Type-I diabetes

    NASA Astrophysics Data System (ADS)

    Mahmud, Farhanahani; Isse, Nadir Hussien; Daud, Nur Atikah Mohd; Morsin, Marlia

    2017-01-01

    This project introduces a simulation of Proportional-Derivative (PD) and Proportional-Integral-Derivative (PID) controller based on a virtual Type 1 Diabetes Mellitus (T1DM) patient: Hovorka diabetic model using MATLAB-Simulink software. The results of these simulations are based on three tuning responses for each controller which are fast, slow and oscillation responses. The main purpose of this simulation is to achieve an acceptable stability and fastness response towards the regulation of glucose concentration using PD and PID controller response with insulin infusion rate. Therefore, in order to analyze and compare the responses of both controller performances, one-day simulations of the insulin-glucose dynamic have been conducted using a typical day meal plan that contains five meals of different bolus size. It is found that the PID closed-loop control with a short rise time is required to retrieve a satisfactory glucose regulation.

  5. Anisotropic fractal media by vector calculus in non-integer dimensional space

    NASA Astrophysics Data System (ADS)

    Tarasov, Vasily E.

    2014-08-01

    A review of different approaches to describe anisotropic fractal media is proposed. In this paper, differentiation and integration non-integer dimensional and multi-fractional spaces are considered as tools to describe anisotropic fractal materials and media. We suggest a generalization of vector calculus for non-integer dimensional space by using a product measure method. The product of fractional and non-integer dimensional spaces allows us to take into account the anisotropy of the fractal media in the framework of continuum models. The integration over non-integer-dimensional spaces is considered. In this paper differential operators of first and second orders for fractional space and non-integer dimensional space are suggested. The differential operators are defined as inverse operations to integration in spaces with non-integer dimensions. Non-integer dimensional space that is product of spaces with different dimensions allows us to give continuum models for anisotropic type of the media. The Poisson's equation for fractal medium, the Euler-Bernoulli fractal beam, and the Timoshenko beam equations for fractal material are considered as examples of application of suggested generalization of vector calculus for anisotropic fractal materials and media.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, Steven P.; Moseley, John; Norman, Andrew

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis.more » By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.« less

  7. An approach to design controllers for MIMO fractional-order plants based on parameter optimization algorithm.

    PubMed

    Xue, Dingyü; Li, Tingxue

    2017-04-27

    The parameter optimization method for multivariable systems is extended to the controller design problems for multiple input multiple output (MIMO) square fractional-order plants. The algorithm can be applied to search for the optimal parameters of integer-order controllers for fractional-order plants with or without time delays. Two examples are given to present the controller design procedures for MIMO fractional-order systems. Simulation studies show that the integer-order controllers designed are robust to plant gain variations. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Improved model reduction and tuning of fractional-order PI(λ)D(μ) controllers for analytical rule extraction with genetic programming.

    PubMed

    Das, Saptarshi; Pan, Indranil; Das, Shantanu; Gupta, Amitava

    2012-03-01

    Genetic algorithm (GA) has been used in this study for a new approach of suboptimal model reduction in the Nyquist plane and optimal time domain tuning of proportional-integral-derivative (PID) and fractional-order (FO) PI(λ)D(μ) controllers. Simulation studies show that the new Nyquist-based model reduction technique outperforms the conventional H(2)-norm-based reduced parameter modeling technique. With the tuned controller parameters and reduced-order model parameter dataset, optimum tuning rules have been developed with a test-bench of higher-order processes via genetic programming (GP). The GP performs a symbolic regression on the reduced process parameters to evolve a tuning rule which provides the best analytical expression to map the data. The tuning rules are developed for a minimum time domain integral performance index described by a weighted sum of error index and controller effort. From the reported Pareto optimal front of the GP-based optimal rule extraction technique, a trade-off can be made between the complexity of the tuning formulae and the control performance. The efficacy of the single-gene and multi-gene GP-based tuning rules has been compared with the original GA-based control performance for the PID and PI(λ)D(μ) controllers, handling four different classes of representative higher-order processes. These rules are very useful for process control engineers, as they inherit the power of the GA-based tuning methodology, but can be easily calculated without the requirement for running the computationally intensive GA every time. Three-dimensional plots of the required variation in PID/fractional-order PID (FOPID) controller parameters with reduced process parameters have been shown as a guideline for the operator. Parametric robustness of the reported GP-based tuning rules has also been shown with credible simulation examples. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Position control of an industrial robot using fractional order controller

    NASA Astrophysics Data System (ADS)

    Clitan, Iulia; Muresan, Vlad; Abrudean, Mihail; Clitan, Andrei; Miron, Radu

    2017-02-01

    This paper presents the design of a control structure that ensures no overshoot for the movement of an industrial robot, used for the evacuation of round steel blocks from inside a rotary hearth furnace. First, a mathematical model for the positioning system is derived from a set of experimental data, and further, the paper focuses on obtaining a PID type controller, using the relay method as tuning method in order to obtain a stable closed loop system. The controller parameters are further tuned in order to achieve the imposed set of performances for the positioning of the industrial robot through computer simulation, using trial and error method. Further, a fractional - order PID controller is obtained in order to improve the control signal variation, so as to fit within the range of unified current's variation, 4 to 20 mA.

  10. Anisotropic fractal media by vector calculus in non-integer dimensional space

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tarasov, Vasily E., E-mail: tarasov@theory.sinp.msu.ru

    2014-08-15

    A review of different approaches to describe anisotropic fractal media is proposed. In this paper, differentiation and integration non-integer dimensional and multi-fractional spaces are considered as tools to describe anisotropic fractal materials and media. We suggest a generalization of vector calculus for non-integer dimensional space by using a product measure method. The product of fractional and non-integer dimensional spaces allows us to take into account the anisotropy of the fractal media in the framework of continuum models. The integration over non-integer-dimensional spaces is considered. In this paper differential operators of first and second orders for fractional space and non-integer dimensionalmore » space are suggested. The differential operators are defined as inverse operations to integration in spaces with non-integer dimensions. Non-integer dimensional space that is product of spaces with different dimensions allows us to give continuum models for anisotropic type of the media. The Poisson's equation for fractal medium, the Euler-Bernoulli fractal beam, and the Timoshenko beam equations for fractal material are considered as examples of application of suggested generalization of vector calculus for anisotropic fractal materials and media.« less

  11. Robust PI and PID design for first- and second-order processes with zeros, time-delay and structured uncertainties

    NASA Astrophysics Data System (ADS)

    Parada, M.; Sbarbaro, D.; Borges, R. A.; Peres, P. L. D.

    2017-01-01

    The use of robust design techniques such as the one based on ? and ? for tuning proportional integral (PI) and proportional integral derivative (PID) controllers have been limited to address a small set of processes. This work addresses the problem by considering a wide set of possible plants, both first- and second-order continuous-time systems with time delays and zeros, leading to PI and PID controllers. The use of structured uncertainties to handle neglected dynamics allows to expand the range of processes to be considered. The proposed approach takes into account the robustness of the controller with respect to these structured uncertainties by using the small-gain theorem. In addition, improved performance is sought through the minimisation of an upper bound to the closed-loop system ? norm. A Lyapunov-Krasovskii-type functional is used to obtain delay-dependent design conditions. The controller design is accomplished by means of a convex optimisation procedure formulated using linear matrix inequalities. In order to illustrate the flexibility of the approach, several examples considering recycle compensation, reduced-order controller design and a practical implementation are addressed. Numerical experiments are provided in each case to highlight the main characteristics of the proposed design method.

  12. Patient-centred screening for primary immunodeficiency: a multi-stage diagnostic protocol designed for non-immunologists

    PubMed Central

    de Vries, E

    2006-01-01

    Efficient early identification of primary immunodeficiency disease (PID) is important for prognosis, but is not an easy task for non-immunologists. The Clinical Working Party of the European Society for Immunodeficiencies (ESID) has composed a multi-stage diagnostic protocol that is based on expert opinion, in order to increase the awareness of PID among doctors working in different fields. The protocol starts from the clinical presentation of the patient; immunological skills are not needed for its use. The multi-stage design allows cost-effective screening for PID within the large pool of potential cases in all hospitals in the early phases, while more expensive tests are reserved for definitive classification in collaboration with an immunologist at a later stage. Although many PIDs present in childhood, others may present at any age. The protocols presented here are therefore aimed at both adult physicians and paediatricians. While designed for use throughout Europe, there will be national differences which may make modification of this generic algorithm necessary. PMID:16879238

  13. Research of digital controlled DC/DC converter based on STC12C5410AD

    NASA Astrophysics Data System (ADS)

    Chen, Dan-Jiang; Jin, Xin; Xiao, Zhi-Hong

    2010-02-01

    In order to study application of digital control technology on DC/DC converter, principle of increment mode PID control algorithm was analyzed in the paper. Then, a SCM named STC12C5410AD was introduced with its internal resources and characteristics. The PID control algorithm can be implemented easily based on it. The output of PID control was used to change the value of a variable that is 255 times than duty cycle, and this reduced the error of calculation. The valid of the presented algorithm was verified by an experiment for a BUCK DC/DC converter. The experimental results indicated that output voltage of the BUCK converter is stable with low ripple.

  14. Vector calculus in non-integer dimensional space and its applications to fractal media

    NASA Astrophysics Data System (ADS)

    Tarasov, Vasily E.

    2015-02-01

    We suggest a generalization of vector calculus for the case of non-integer dimensional space. The first and second orders operations such as gradient, divergence, the scalar and vector Laplace operators for non-integer dimensional space are defined. For simplification we consider scalar and vector fields that are independent of angles. We formulate a generalization of vector calculus for rotationally covariant scalar and vector functions. This generalization allows us to describe fractal media and materials in the framework of continuum models with non-integer dimensional space. As examples of application of the suggested calculus, we consider elasticity of fractal materials (fractal hollow ball and fractal cylindrical pipe with pressure inside and outside), steady distribution of heat in fractal media, electric field of fractal charged cylinder. We solve the correspondent equations for non-integer dimensional space models.

  15. Hybridization with a twist: Hidden (hastatic) order in URu2Si2

    NASA Astrophysics Data System (ADS)

    Flint, Rebecca

    The hidden order developing below 17.5K in the heavy fermion material URu2Si2 has eluded identification for over thirty years. A number of recent experiments have shed new light on the nature of this phase. In particular, de Haas-van Alphen measurements indicate nearly perfectly Ising quasiparticles deep in the hidden order phase, and recent nonlinear susceptibility measurements show that this strong Ising anisotropy persists up to and above the hidden order transition itself. Along with other features, this Ising anisotropy implies that the conduction electrons hybridize with a local Ising moment - a 5f2 state of the uranium atom with integer spin. As the hybridization mixes states of integer and half-integer spin, it is itself a spinor and this ``hastatic'' (hasta: [Latin] spear) order parameter therefore breaks both time-reversal and double time-reversal symmetries. A microscopic theory of hastatic order naturally unites a number of disparate experimental results from the large entropy of condensation to the spin rotational symmetry breaking seen in torque magnetometry, and provides a number of experimental predictions. Moreover, this new spinorial order parameter provides a window into a number of new heavy fermion phases.

  16. Robotic excavator trajectory control using an improved GA based PID controller

    NASA Astrophysics Data System (ADS)

    Feng, Hao; Yin, Chen-Bo; Weng, Wen-wen; Ma, Wei; Zhou, Jun-jing; Jia, Wen-hua; Zhang, Zi-li

    2018-05-01

    In order to achieve excellent trajectory tracking performances, an improved genetic algorithm (IGA) is presented to search for the optimal proportional-integral-derivative (PID) controller parameters for the robotic excavator. Firstly, the mathematical model of kinematic and electro-hydraulic proportional control system of the excavator are analyzed based on the mechanism modeling method. On this basis, the actual model of the electro-hydraulic proportional system are established by the identification experiment. Furthermore, the population, the fitness function, the crossover probability and mutation probability of the SGA are improved: the initial PID parameters are calculated by the Ziegler-Nichols (Z-N) tuning method and the initial population is generated near it; the fitness function is transformed to maintain the diversity of the population; the probability of crossover and mutation are adjusted automatically to avoid premature convergence. Moreover, a simulation study is carried out to evaluate the time response performance of the proposed controller, i.e., IGA based PID against the SGA and Z-N based PID controllers with a step signal. It was shown from the simulation study that the proposed controller provides the least rise time and settling time of 1.23 s and 1.81 s, respectively against the other tested controllers. Finally, two types of trajectories are designed to validate the performances of the control algorithms, and experiments are performed on the excavator trajectory control experimental platform. It was demonstrated from the experimental work that the proposed IGA based PID controller improves the trajectory accuracy of the horizontal line and slope line trajectories by 23.98% and 23.64%, respectively in comparison to the SGA tuned PID controller. The results further indicate that the proposed IGA tuning based PID controller is effective for improving the tracking accuracy, which may be employed in the trajectory control of an actual excavator.

  17. Negative Integer Understanding: Characterizing First Graders' Mental Models

    ERIC Educational Resources Information Center

    Bofferding, Laura

    2014-01-01

    This article presents results of a research study. Sixty-one first graders' responses to interview questions about negative integer values and order and directed magnitudes were examined to characterize the students' mental models. The models reveal that initially, students overrelied on various combinations of whole-number principles as…

  18. Optimal Self-Tuning PID Controller Based on Low Power Consumption for a Server Fan Cooling System.

    PubMed

    Lee, Chengming; Chen, Rongshun

    2015-05-20

    Recently, saving the cooling power in servers by controlling the fan speed has attracted considerable attention because of the increasing demand for high-density servers. This paper presents an optimal self-tuning proportional-integral-derivative (PID) controller, combining a PID neural network (PIDNN) with fan-power-based optimization in the transient-state temperature response in the time domain, for a server fan cooling system. Because the thermal model of the cooling system is nonlinear and complex, a server mockup system simulating a 1U rack server was constructed and a fan power model was created using a third-order nonlinear curve fit to determine the cooling power consumption by the fan speed control. PIDNN with a time domain criterion is used to tune all online and optimized PID gains. The proposed controller was validated through experiments of step response when the server operated from the low to high power state. The results show that up to 14% of a server's fan cooling power can be saved if the fan control permits a slight temperature response overshoot in the electronic components, which may provide a time-saving strategy for tuning the PID controller to control the server fan speed during low fan power consumption.

  19. Research on frequency control strategy of interconnected region based on fuzzy PID

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Li, Chunlan

    2018-05-01

    In order to improve the frequency control performance of the interconnected power grid, overcome the problems of poor robustness and slow adjustment of traditional regulation, the paper puts forward a frequency control method based on fuzzy PID. The method takes the frequency deviation and tie-line deviation of each area as the control objective, takes the regional frequency deviation and its deviation as input, and uses fuzzy mathematics theory, adjusts PID control parameters online. By establishing the regional frequency control model of water-fire complementary power generation in MATLAB, the regional frequency control strategy is given, and three control modes (TBC-FTC, FTC-FTC, FFC-FTC) are simulated and analyzed. The simulation and experimental results show that, this method has better control performance compared with the traditional regional frequency regulation.

  20. An improved PID switching control strategy for type 1 diabetes.

    PubMed

    Marchetti, Gianni; Barolo, Massimiliano; Jovanovic, Lois; Zisser, Howard; Seborg, Dale E

    2006-01-01

    In order for an "artificial pancreas" to become a reality for ambulatory use, a practical closed-loop control strategy must be developed and critically evaluated. In this paper, an improved PID control strategy for blood glucose control is proposed and evaluated in silico using a physiologic model of Hovorka et al. The key features of the proposed control strategy are: (i) a switching strategy for initiating PID control after a meal and insulin bolus; (ii) a novel time-varying setpoint trajectory, (iii) noise and derivative filters to reduce sensitivity to sensor noise, and (iv) a systematic controller tuning strategy. Simulation results demonstrate that the proposed control strategy compares favorably to alternatives for realistic conditions that include meal challenges, incorrect carbohydrate meal estimates, changes in insulin sensitivity, and measurement noise.

  1. Development of a GA-Fuzzy-Immune PID Controller with Incomplete Derivation for Robot Dexterous Hand

    PubMed Central

    Liu, Xin-hua; Chen, Xiao-hu; Zheng, Xian-hua; Li, Sheng-peng; Wang, Zhong-bin

    2014-01-01

    In order to improve the performance of robot dexterous hand, a controller based on GA-fuzzy-immune PID was designed. The control system of a robot dexterous hand and mathematical model of an index finger were presented. Moreover, immune mechanism was applied to the controller design and an improved approach through integration of GA and fuzzy inference was proposed to realize parameters' optimization. Finally, a simulation example was provided and the designed controller was proved ideal. PMID:25097881

  2. Parameters-tuning of PID controller for automatic voltage regulators using the African buffalo optimization.

    PubMed

    Odili, Julius Beneoluchi; Mohmad Kahar, Mohd Nizam; Noraziah, A

    2017-01-01

    In this paper, an attempt is made to apply the African Buffalo Optimization (ABO) to tune the parameters of a PID controller for an effective Automatic Voltage Regulator (AVR). Existing metaheuristic tuning methods have been proven to be quite successful but there were observable areas that need improvements especially in terms of the system's gain overshoot and steady steady state errors. Using the ABO algorithm where each buffalo location in the herd is a candidate solution to the Proportional-Integral-Derivative parameters was very helpful in addressing these two areas of concern. The encouraging results obtained from the simulation of the PID Controller parameters-tuning using the ABO when compared with the performance of Genetic Algorithm PID (GA-PID), Particle-Swarm Optimization PID (PSO-PID), Ant Colony Optimization PID (ACO-PID), PID, Bacteria-Foraging Optimization PID (BFO-PID) etc makes ABO-PID a good addition to solving PID Controller tuning problems using metaheuristics.

  3. PID-controller with predictor and auto-tuning algorithm: study of efficiency for thermal plants

    NASA Astrophysics Data System (ADS)

    Kuzishchin, V. F.; Merzlikina, E. I.; Hoang, Van Va

    2017-09-01

    The problem of efficiency estimation of an automatic control system (ACS) with a Smith predictor and PID-algorithm for thermal plants is considered. In order to use the predictor, it is proposed to include an auto-tuning module (ATC) into the controller; the module calculates parameters for a second-order plant module with a time delay. The study was conducted using programmable logical controllers (PLC), one of which performed control, ATC, and predictor functions. A simulation model was used as a control plant, and there were two variants of the model: one of them was built on the basis of a separate PLC, and the other was a physical model of a thermal plant in the form of an electrical heater. Analysis of the efficiency of the ACS with the predictor was carried out for several variants of the second order plant model with time delay, and the analysis was performed on the basis of the comparison of transient processes in the system when the set point was changed and when a disturbance influenced the control plant. The recommendations are given on correction of the PID-algorithm parameters when the predictor is used by means of using the correcting coefficient k for the PID parameters. It is shown that, when the set point is changed, the use of the predictor is effective taking into account the parameters correction with k = 2. When the disturbances influence the plant, the use of the predictor is doubtful, because the transient process is too long. The reason for this is that, in the neighborhood of the zero frequency, the amplitude-frequency characteristic (AFC) of the system with the predictor has an ascent in comparison with the AFC of the system without the predictor.

  4. The Psychometric Properties of the French Version of the Personality Inventory for DSM-5

    PubMed Central

    Roskam, Isabelle; Galdiolo, Sarah; Hansenne, Michel; Massoudi, Koorosh; Rossier, Jérôme; Gicquel, Ludovic; Rolland, Jean-Pierre

    2015-01-01

    In the context of the publication of DSM-5, the Personality Inventory for DSM-5 (PID-5) has been proposed as a new dimensional assessment tool for personality disorders. This instrument includes a pool of 220 items organized around 25 facets included in a five-factor second-order domain structure. The examination of the replicability of the trait structure across methods and populations is of primary importance. In view of this need, the main objective of the current study was to validate the French version of the PID-5 among French-speaking adults from a European community sample (N=2,532). In particular, the assumption of unidimensionality of the 25 facet and the five domain scales was tested, as well as the extent to which the five-factor structure of the PID-5 and the DSM-5 personality trait hierarchical structure are replicated in the current sample. The results support the assumption of unidimensionality of both the facets and the domains. Exploratory factor and hierarchical analyses replicated the five-factor structure as initially proposed in the PID-5. PMID:26193699

  5. The Psychometric Properties of the French Version of the Personality Inventory for DSM-5.

    PubMed

    Roskam, Isabelle; Galdiolo, Sarah; Hansenne, Michel; Massoudi, Koorosh; Rossier, Jérôme; Gicquel, Ludovic; Rolland, Jean-Pierre

    2015-01-01

    In the context of the publication of DSM-5, the Personality Inventory for DSM-5 (PID-5) has been proposed as a new dimensional assessment tool for personality disorders. This instrument includes a pool of 220 items organized around 25 facets included in a five-factor second-order domain structure. The examination of the replicability of the trait structure across methods and populations is of primary importance. In view of this need, the main objective of the current study was to validate the French version of the PID-5 among French-speaking adults from a European community sample (N=2,532). In particular, the assumption of unidimensionality of the 25 facet and the five domain scales was tested, as well as the extent to which the five-factor structure of the PID-5 and the DSM-5 personality trait hierarchical structure are replicated in the current sample. The results support the assumption of unidimensionality of both the facets and the domains. Exploratory factor and hierarchical analyses replicated the five-factor structure as initially proposed in the PID-5.

  6. A comparative study of stabilizing control of a planer electromagnetic levitation using PID and LQR controllers

    NASA Astrophysics Data System (ADS)

    Yaseen, Mundher H. A.

    Magnetic levitation is a technique to suspend an object without any mechanical support. The main objective of this study is to demonstrate stabilized closed loop control of 1-DOF Maglev experimentally using real-time control simulink feature of (SIMLAB) microcontroller. Proportional Integral Derivative (PID) and Linear Quadratic Regulator (LQR) controllers are employed to examine the stability performance of the Maglev control system under effect of unbalanced change of load and wave signal on Maglev plane. The effect of unbalanced change of applied load on single point, line and plane are presented. Furthermore, in order to study the effect of sudden change in input signal, the input of wave signal has been applied on all points of the prototype maglev plate simultaneously. The results of pulse width modulation (PWM) reveal that the control system using LQR controller provides faster response to adjust the levitated plane comparing to PID controller. Moreover, the air gap distance that controlled using PID controller is rather stable with little oscillation. Meanwhile, LQR controller provided more stability and homogeneous response.

  7. SU-F-J-10: Sliding Mode Control of a SMA Actuated Active Flexible Needle for Medical Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podder, T

    Purpose: In medical interventional procedures such as brachytherapy, ablative therapies and biopsy precise steering and accurate placement of needles are very important for anatomical obstacle avoidance and accurate targeting. This study presents the efficacy of a sliding mode controller for Shape Memory Alloy (SMA) actuated flexible needle for medical procedures. Methods: Second order system dynamics of the SMA actuated active flexible needle was used for deriving the sliding mode control equations. Both proportional-integral-derivative (PID) and adaptive PID sliding mode control (APIDSMC) algorithms were developed and implemented. The flexible needle was attached at the end of a 6 DOF robotic system.more » Through LabView programming environment, the control commands were generated using the PID and APIDSMC algorithms. Experiments with artificial tissue mimicking phantom were performed to evaluate the performance of the controller. The actual needle tip position was obtained using an electromagnetic (EM) tracking sensor (Aurora, NDI, waterloo, Canada) at a sampling period of 1ms. During experiment, external disturbances were created applying force and thermal shock to investigate the robustness of the controllers. Results: The root mean square error (RMSE) values for APIDSMC and PID controllers were 0.75 mm and 0.92 mm, respectively, for sinusoidal reference input. In the presence of external disturbances, the APIDSMC controller showed much smoother and less overshooting response compared to that of the PID controller. Conclusion: Performance of the APIDSMC was superior to the PID controller. The APIDSMC was proved to be more effective controller in compensating the SMA uncertainties and external disturbances with clinically acceptable thresholds.« less

  8. Triangular Numbers, Gaussian Integers, and KenKen

    ERIC Educational Resources Information Center

    Watkins, John J.

    2012-01-01

    Latin squares form the basis for the recreational puzzles sudoku and KenKen. In this article we show how useful several ideas from number theory are in solving a KenKen puzzle. For example, the simple notion of triangular number is surprisingly effective. We also introduce a variation of KenKen that uses the Gaussian integers in order to…

  9. Trustworthy persistent identifier systems of the future

    NASA Astrophysics Data System (ADS)

    Golodoniuc, Pavel; Klump, Jens; Car, Nicholas

    2016-04-01

    Over the last two decades, persistent identifier (PID) systems have seen some significant changes in their governance policies, system capabilities, and technology. The development of most systems was driven by two main application areas, namely archives and libraries. Guidelines and criteria for trustworthy PID systems have been clearly devised (Bütikofer, 2009) and many PID system implementations for the identification of static digital objects have been built (e.g., PURL). However systems delivering persistent identifiers for dynamic datasets are not yet mature. There has been a rapid proliferation of different PID systems caused by the specific technical or organisational requirements of various communities that could not be met by existing systems such as DOI, ISBN, and EAN. Many of these different systems were limited by their inability to provide native means of persistent identifier resolution. This has prompted a decoupling of PID-associated data from the resolution service and this is where the Handle system has played a significant role. The Handle allowed to build a distributed system of independently managed resolver services. A trustworthy PID system must be designed to outlive the objects it provides persistent identifiers for, which may cease to exist or otherwise be deprecated, and the technology used to implement it, which will certainly need to change with time. We propose that such a system should rest on four pillars of agreements - (i) definitions, (ii) policies, (iii) services, and (iv) data services, to ensure longevity. While we believe all four pillars are equally important, we intentionally leave regulating aspects of issuing of identifiers and their registration out of the scope of this paper and focus on the agreements that have to be established between PID resolver services and the data sources indicated by the persistent identifiers. We propose an approach to development of PID systems that combines the use of (a) the Handle system as a highly distributed system of independent nodes that provides registration and first-degree resolution facilities for persistent identifiers, and (b) the PID Service tool to enable fine-grained resolution of object representations in dynamic datasets using parameterized requests. The PID Service, deployed in close proximity to data services and managed by individual organisations, gives great flexibility and control over multiple representations and versions of information objects in data stores while allowing basic resolution via the Handle system. Through the assessment proposals and implementation example we give, we highlight a critical aspect of PID system design and implementation that we believe is often neglected - the protocols and procedures required for PID system decommissioning. These protocols and procedures are needed in order for PID systems' core data to be able to be transferred to successor systems when current systems need replacing, as we indicate they inevitably will. Not knowing what successor systems may be, we strongly believe in using open standard formats as this gives future system implementers the best possible chance of being able to work with the data export. Smooth system handover will ensure that identifiers minted today will actually persist into the future.

  10. Convergence of fractional adaptive systems using gradient approach.

    PubMed

    Gallegos, Javier A; Duarte-Mermoud, Manuel A

    2017-07-01

    Conditions for boundedness and convergence of the output error and the parameter error for various Caputo's fractional order adaptive schemes based on the steepest descent method are derived in this paper. To this aim, the concept of sufficiently exciting signals is introduced, characterized and related to the concept of persistently exciting signals used in the integer order case. An application is designed in adaptive indirect control of integer order systems using fractional equations to adjust parameters. This application is illustrated for a pole placement adaptive problem. Advantages of using fractional adjustment in control adaptive schemes are experimentally obtained. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  11. Pole-zero form fractional model identification in frequency domain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mansouri, R.; Djamah, T.; Djennoune, S.

    2009-03-05

    This paper deals with system identification in the frequency domain using non integer order models given in the pole-zero form. The usual identification techniques cannot be used in this case because of the non integer orders of differentiation which makes the problem strongly nonlinear. A general identification method based on Levenberg-Marquardt algorithm is developed and allows to estimate the (2n+2m+1) parameters of the model. Its application to identify the ''skin effect'' of a squirrel cage induction machine modeling is then presented.

  12. The use of fractional orders in the determination of birefringence of highly dispersive materials by the channelled spectrum method

    NASA Astrophysics Data System (ADS)

    Nagarajan, K.; Shashidharan Nair, C. K.

    2007-07-01

    The channelled spectrum employing polarized light interference is a very convenient method for the study of dispersion of birefringence. However, while using this method, the absolute order of the polarized light interference fringes cannot be determined easily. Approximate methods are therefore used to estimate the order. One of the approximations is that the dispersion of birefringence across neighbouring integer order fringes is negligible. In this paper, we show how this approximation can cause errors. A modification is reported whereby the error in the determination of absolute fringe order can be reduced using fractional orders instead of integer orders. The theoretical background for this method supported with computer simulation is presented. An experimental arrangement implementing these modifications is described. This method uses a Constant Deviation Spectrometer (CDS) and a Soleil Babinet Compensator (SBC).

  13. Servo Platform Circuit Design of Pendulous Gyroscope Based on DSP

    NASA Astrophysics Data System (ADS)

    Tan, Lilong; Wang, Pengcheng; Zhong, Qiyuan; Zhang, Cui; Liu, Yunfei

    2018-03-01

    In order to solve the problem when a certain type of pendulous gyroscope in the initial installation deviation more than 40 degrees, that the servo platform can not be up to the speed of the gyroscope in the rough north seeking phase. This paper takes the digital signal processor TMS320F28027 as the core, uses incremental digital PID algorithm, carries out the circuit design of the servo platform. Firstly, the hardware circuit is divided into three parts: DSP minimum system, motor driving circuit and signal processing circuit, then the mathematical model of incremental digital PID algorithm is established, based on the model, writes the PID control program in CCS3.3, finally, the servo motor tracking control experiment is carried out, it shows that the design can significantly improve the tracking ability of the servo platform, and the design has good engineering practice.

  14. Closed-Loop Control of Chemical Injection Rate for a Direct Nozzle Injection System.

    PubMed

    Cai, Xiang; Walgenbach, Martin; Doerpmond, Malte; Schulze Lammers, Peter; Sun, Yurui

    2016-01-20

    To realize site-specific and variable-rate application of agricultural pesticides, accurately metering and controlling the chemical injection rate is necessary. This study presents a prototype of a direct nozzle injection system (DNIS) by which chemical concentration transport lag was greatly reduced. In this system, a rapid-reacting solenoid valve (RRV) was utilized for injecting chemicals, driven by a pulse-width modulation (PWM) signal at 100 Hz, so with varying pulse width the chemical injection rate could be adjusted. Meanwhile, a closed-loop control strategy, proportional-integral-derivative (PID) method, was applied for metering and stabilizing the chemical injection rate. In order to measure chemical flow rates and input them into the controller as a feedback in real-time, a thermodynamic flowmeter that was independent of chemical viscosity was used. Laboratory tests were conducted to assess the performance of DNIS and PID control strategy. Due to the nonlinear input-output characteristics of the RRV, a two-phase PID control process obtained better effects as compared with single PID control strategy. Test results also indicated that the set-point chemical flow rate could be achieved within less than 4 s, and the output stability was improved compared to the case without control strategy.

  15. Digitally controlled analog proportional-integral-derivative (PID) controller for high-speed scanning probe microscopy

    NASA Astrophysics Data System (ADS)

    Dukic, Maja; Todorov, Vencislav; Andany, Santiago; Nievergelt, Adrian P.; Yang, Chen; Hosseini, Nahid; Fantner, Georg E.

    2017-12-01

    Nearly all scanning probe microscopes (SPMs) contain a feedback controller, which is used to move the scanner in the direction of the z-axis in order to maintain a constant setpoint based on the tip-sample interaction. The most frequently used feedback controller in SPMs is the proportional-integral (PI) controller. The bandwidth of the PI controller presents one of the speed limiting factors in high-speed SPMs, where higher bandwidths enable faster scanning speeds and higher imaging resolution. Most SPM systems use digital signal processor-based PI feedback controllers, which require analog-to-digital and digital-to-analog converters. These converters introduce additional feedback delays which limit the achievable imaging speed and resolution. In this paper, we present a digitally controlled analog proportional-integral-derivative (PID) controller. The controller implementation allows tunability of the PID gains over a large amplification and frequency range, while also providing precise control of the system and reproducibility of the gain parameters. By using the analog PID controller, we were able to perform successful atomic force microscopy imaging of a standard silicon calibration grating at line rates up to several kHz.

  16. Digitally controlled analog proportional-integral-derivative (PID) controller for high-speed scanning probe microscopy.

    PubMed

    Dukic, Maja; Todorov, Vencislav; Andany, Santiago; Nievergelt, Adrian P; Yang, Chen; Hosseini, Nahid; Fantner, Georg E

    2017-12-01

    Nearly all scanning probe microscopes (SPMs) contain a feedback controller, which is used to move the scanner in the direction of the z-axis in order to maintain a constant setpoint based on the tip-sample interaction. The most frequently used feedback controller in SPMs is the proportional-integral (PI) controller. The bandwidth of the PI controller presents one of the speed limiting factors in high-speed SPMs, where higher bandwidths enable faster scanning speeds and higher imaging resolution. Most SPM systems use digital signal processor-based PI feedback controllers, which require analog-to-digital and digital-to-analog converters. These converters introduce additional feedback delays which limit the achievable imaging speed and resolution. In this paper, we present a digitally controlled analog proportional-integral-derivative (PID) controller. The controller implementation allows tunability of the PID gains over a large amplification and frequency range, while also providing precise control of the system and reproducibility of the gain parameters. By using the analog PID controller, we were able to perform successful atomic force microscopy imaging of a standard silicon calibration grating at line rates up to several kHz.

  17. Second-order sliding mode control with experimental application.

    PubMed

    Eker, Ilyas

    2010-07-01

    In this article, a second-order sliding mode control (2-SMC) is proposed for second-order uncertain plants using equivalent control approach to improve the performance of control systems. A Proportional + Integral + Derivative (PID) sliding surface is used for the sliding mode. The sliding mode control law is derived using direct Lyapunov stability approach and asymptotic stability is proved theoretically. The performance of the closed-loop system is analysed through an experimental application to an electromechanical plant to show the feasibility and effectiveness of the proposed second-order sliding mode control and factors involved in the design. The second-order plant parameters are experimentally determined using input-output measured data. The results of the experimental application are presented to make a quantitative comparison with the traditional (first-order) sliding mode control (SMC) and PID control. It is demonstrated that the proposed 2-SMC system improves the performance of the closed-loop system with better tracking specifications in the case of external disturbances, better behavior of the output and faster convergence of the sliding surface while maintaining the stability. 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Improvement of cardiac function with device-based diaphragmatic stimulation in chronic heart failure patients: the randomized, open-label, crossover Epiphrenic II Pilot Trial.

    PubMed

    Beeler, Remo; Schoenenberger, Andreas W; Bauer, Peter; Kobza, Richard; Bergner, Michael; Mueller, Xavier; Schlaepfer, Reinhard; Zuber, Michel; Erne, Susanne; Erne, Paul

    2014-03-01

    Device-based pacing-induced diaphragmatic stimulation (PIDS) may have therapeutic potential for chronic heart failure (HF) patients. We studied the effects of PIDS on cardiac function and functional outcomes. In 24 chronic HF patients with CRT, an additional electrode was attached to the left diaphragm. Randomized into two groups, patients received the following PIDS modes for 3 weeks in a different sequence: (i) PIDS off (control group); (ii) PIDS 0 ms mode (PIDS simultaneously with ventricular CRT pulse); or (iii) PIDS optimized mode (PIDS with optimized delay to ventricular CRT pulse). For PIDS optimization, acoustic cardiography was used. Effects of each PIDS mode on dyspnoea, power during exercise testing, and LVEF were assessed. Dyspnoea improved with the PIDS 0 ms mode (P = 0.057) and the PIDS optimized mode (P = 0.034) as compared with the control group. Maximal power increased from median 100.5 W in the control group to 104.0 W in the PIDS 0 ms mode (P = 0.092) and 109.5 W in the PIDS optimized mode (P = 0.022). Median LVEF was 33.5% in the control group, 33.0% in the PIDS 0 ms mode, and 37.0% in the PIDS optimized mode (P = 0.763 and P = 0.009 as compared with the control group, respectively). PIDS was asymptomatic in all patients. PIDS improves dyspnoea, working capacity, and LVEF in chronic HF patients over a 3 week period in addition to CRT. This pilot study demonstrates proof of principle of an innovative technology which should be confirmed in a larger sample. NCT00769678. © 2013 The Authors. European Journal of Heart Failure © 2013 European Society of Cardiology.

  19. Integer sequence discovery from small graphs

    PubMed Central

    Hoppe, Travis; Petrone, Anna

    2015-01-01

    We have exhaustively enumerated all simple, connected graphs of a finite order and have computed a selection of invariants over this set. Integer sequences were constructed from these invariants and checked against the Online Encyclopedia of Integer Sequences (OEIS). 141 new sequences were added and six sequences were extended. From the graph database, we were able to programmatically suggest relationships among the invariants. It will be shown that we can readily visualize any sequence of graphs with a given criteria. The code has been released as an open-source framework for further analysis and the database was constructed to be extensible to invariants not considered in this work. PMID:27034526

  20. Fractional-order in a macroeconomic dynamic model

    NASA Astrophysics Data System (ADS)

    David, S. A.; Quintino, D. D.; Soliani, J.

    2013-10-01

    In this paper, we applied the Riemann-Liouville approach in order to realize the numerical simulations to a set of equations that represent a fractional-order macroeconomic dynamic model. It is a generalization of a dynamic model recently reported in the literature. The aforementioned equations have been simulated for several cases involving integer and non-integer order analysis, with some different values to fractional order. The time histories and the phase diagrams have been plotted to visualize the effect of fractional order approach. The new contribution of this work arises from the fact that the macroeconomic dynamic model proposed here involves the public sector deficit equation, which renders the model more realistic and complete when compared with the ones encountered in the literature. The results reveal that the fractional-order macroeconomic model can exhibit a real reasonable behavior to macroeconomics systems and might offer greater insights towards the understanding of these complex dynamic systems.

  1. Stochastic Semidefinite Programming: Applications and Algorithms

    DTIC Science & Technology

    2012-03-03

    doi: 2011/09/07 13:38:21 13 TOTAL: 1 Number of Papers published in non peer-reviewed journals: Baha M. Alzalg and K. A. Ariyawansa, Stochastic...symmetric programming over integers. International Conference on Scientific Computing, Las Vegas, Nevada, July 18--21, 2011. Baha M. Alzalg. On recent...Proceeding publications (other than abstracts): PaperReceived Baha M. Alzalg, K. A. Ariyawansa. Stochastic mixed integer second-order cone programming

  2. Direct and indirect effects of screening for Chlamydia trachomatis on the prevention of pelvic inflammatory disease: a mathematical modeling study.

    PubMed

    Herzog, Sereina A; Heijne, Janneke C M; Scott, Pippa; Althaus, Christian L; Low, Nicola

    2013-11-01

    Pelvic inflammatory disease (PID) results from the ascending spread of microorganisms, including Chlamydia trachomatis, to the upper genital tract. Screening could improve outcomes by identifying and treating chlamydial infections before they progress to PID (direct effect) or by reducing chlamydia transmission (indirect effect). We developed a compartmental model that represents a hypothetical heterosexual population and explicitly incorporates progression from chlamydia to clinical PID. Chlamydia screening was introduced, with coverage increasing each year for 10 years. We estimated the separate contributions of the direct and indirect effects of screening on PID cases prevented per 100,000 women. We explored the influence of varying the time point at which clinical PID could occur and of increasing the risk of PID after repeated chlamydial infections. The probability of PID at baseline was 3.1% by age 25 years. After 5 years, the intervention scenario had prevented 187 PID cases per 100,000 women and after 10 years 956 PID cases per 100,000 women. At the start of screening, most PID cases were prevented by the direct effect. The indirect effect produced a small net increase in PID cases, which was outweighed by the effect of reduced chlamydia transmission after 2.2 years. The later that progression to PID occurs, the greater the contribution of the direct effect. Increasing the risk of PID with repeated chlamydial infection increases the number of PID cases prevented by screening. This study shows the separate roles of direct and indirect PID prevention and potential harms, which cannot be demonstrated in observational studies.

  3. A new Fortran 90 program to compute regular and irregular associated Legendre functions (new version announcement)

    NASA Astrophysics Data System (ADS)

    Schneider, Barry I.; Segura, Javier; Gil, Amparo; Guan, Xiaoxu; Bartschat, Klaus

    2018-04-01

    This is a revised and updated version of a modern Fortran 90 code to compute the regular Plm (x) and irregular Qlm (x) associated Legendre functions for all x ∈(- 1 , + 1) (on the cut) and | x | > 1 and integer degree (l) and order (m). The necessity to revise the code comes as a consequence of some comments of Prof. James Bremer of the UC//Davis Mathematics Department, who discovered that there were errors in the code for large integer degree and order for the normalized regular Legendre functions on the cut.

  4. Optimization of hydraulic turbine governor parameters based on WPA

    NASA Astrophysics Data System (ADS)

    Gao, Chunyang; Yu, Xiangyang; Zhu, Yong; Feng, Baohao

    2018-01-01

    The parameters of hydraulic turbine governor directly affect the dynamic characteristics of the hydraulic unit, thus affecting the regulation capacity and the power quality of power grid. The governor of conventional hydropower unit is mainly PID governor with three adjustable parameters, which are difficult to set up. In order to optimize the hydraulic turbine governor, this paper proposes wolf pack algorithm (WPA) for intelligent tuning since the good global optimization capability of WPA. Compared with the traditional optimization method and PSO algorithm, the results show that the PID controller designed by WPA achieves a dynamic quality of hydraulic system and inhibits overshoot.

  5. Rule-based navigation control design for autonomous flight

    NASA Astrophysics Data System (ADS)

    Contreras, Hugo; Bassi, Danilo

    2008-04-01

    This article depicts a navigation control system design that is based on a set of rules in order to follow a desired trajectory. The full control of the aircraft considered here comprises: a low level stability control loop, based on classic PID controller and the higher level navigation whose main job is to exercise lateral control (course) and altitude control, trying to follow a desired trajectory. The rules and PID gains were adjusted systematically according to the result of flight simulation. In spite of its simplicity, the rule-based navigation control proved to be robust, even with big perturbation, like crossing winds.

  6. Model-order reduction of lumped parameter systems via fractional calculus

    NASA Astrophysics Data System (ADS)

    Hollkamp, John P.; Sen, Mihir; Semperlotti, Fabio

    2018-04-01

    This study investigates the use of fractional order differential models to simulate the dynamic response of non-homogeneous discrete systems and to achieve efficient and accurate model order reduction. The traditional integer order approach to the simulation of non-homogeneous systems dictates the use of numerical solutions and often imposes stringent compromises between accuracy and computational performance. Fractional calculus provides an alternative approach where complex dynamical systems can be modeled with compact fractional equations that not only can still guarantee analytical solutions, but can also enable high levels of order reduction without compromising on accuracy. Different approaches are explored in order to transform the integer order model into a reduced order fractional model able to match the dynamic response of the initial system. Analytical and numerical results show that, under certain conditions, an exact match is possible and the resulting fractional differential models have both a complex and frequency-dependent order of the differential operator. The implications of this type of approach for both model order reduction and model synthesis are discussed.

  7. Disturbance observer-based adaptive sliding mode hybrid projective synchronisation of identical fractional-order financial systems

    NASA Astrophysics Data System (ADS)

    Khan, Ayub; Tyagi, Arti

    2018-05-01

    In this paper, we have studied the hybrid projective synchronisation for incommensurate, integer and commensurate fractional-order financial systems with unknown disturbance. To tackle the problem of unknown bounded disturbance, fractional-order disturbance observer is designed to approximate the unknown disturbance. Further, we have introduced simple sliding mode surface and designed adaptive sliding mode controllers incorporating with the designed fractional-order disturbance observer to achieve a bounded hybrid projective synchronisation between two identical fractional-order financial model with different initial conditions. It is shown that the slave system with disturbance can be synchronised with the projection of the master system generated through state transformation. Simulation results are presented to ensure the validity and effectiveness of the proposed sliding mode control scheme in the presence of external bounded unknown disturbance. Also, synchronisation error for commensurate, integer and incommensurate fractional-order financial systems is studied in numerical simulation.

  8. Clinical features that identify children with primary immunodeficiency diseases.

    PubMed

    Subbarayan, Anbezhil; Colarusso, Gloria; Hughes, Stephen M; Gennery, Andrew R; Slatter, Mary; Cant, Andrew J; Arkwright, Peter D

    2011-05-01

    The 10 warning signs of primary immunodeficiency diseases (PID) have been promoted by various organizations in Europe and the United States to predict PID. However, the ability of these warning signs to identify children with PID has not been rigorously tested. The main goal of this study was to determine the effectiveness of these 10 warning signs in predicting defined PID among children who presented to 2 tertiary pediatric immunodeficiency centers in the north of England. A retrospective survey of 563 children who presented to 2 pediatric immunodeficiency centers was undertaken. The clinical records of 430 patients with a defined PID and 133 patients for whom detailed investigations failed to establish a specific PID were reviewed. Overall, 96% of the children with PID were referred by hospital clinicians. The strongest identifiers of PID were a family history of immunodeficiency disease in addition to use of intravenous antibiotics for sepsis in children with neutrophil PID and failure to thrive in children with T-lymphocyte PID. With these 3 signs, 96% of patients with neutrophil and complement deficiencies and 89% of children with T-lymphocyte immunodeficiencies could be identified correctly. Family history was the only warning sign that identified children with B-lymphocyte PID. PID awareness initiatives should be targeted at hospital pediatricians and families with a history of PID rather than the general public. Our results provide the general pediatrician with a simple refinement of 10 warning signs for identifying children with underlying immunodeficiency diseases.

  9. A robust fractional-order PID controller design based on active queue management for TCP network

    NASA Astrophysics Data System (ADS)

    Hamidian, Hamideh; Beheshti, Mohammad T. H.

    2018-01-01

    In this paper, a robust fractional-order controller is designed to control the congestion in transmission control protocol (TCP) networks with time-varying parameters. Fractional controllers can increase the stability and robustness. Regardless of advantages of fractional controllers, they are still not common in congestion control in TCP networks. The network parameters are time-varying, so the robust stability is important in congestion controller design. Therefore, we focused on the robust controller design. The fractional PID controller is developed based on active queue management (AQM). D-partition technique is used. The most important property of designed controller is the robustness to the time-varying parameters of the TCP network. The vertex quasi-polynomials of the closed-loop characteristic equation are obtained, and the stability boundaries are calculated for each vertex quasi-polynomial. The intersection of all stability regions is insensitive to network parameter variations, and results in robust stability of TCP/AQM system. NS-2 simulations show that the proposed algorithm provides a stable queue length. Moreover, simulations show smaller oscillations of the queue length and less packet drop probability for FPID compared to PI and PID controllers. We can conclude from NS-2 simulations that the average packet loss probability variations are negligible when the network parameters change.

  10. PID tuning rules for SOPDT systems: review and some new results.

    PubMed

    Panda, Rames C; Yu, Cheng-Ching; Huang, Hsiao-Ping

    2004-04-01

    PID controllers are widely used in industries and so many tuning rules have been proposed over the past 50 years that users are often lost in the jungle of tuning formulas. Moreover, unlike PI control, different control laws and structures of implementation further complicate the use of the PID controller. In this work, five different tuning rules are taken for study to control second-order plus dead time systems with wide ranges of damping coefficients and dead time to time constant ratios (D/tau). Four of them are based on IMC design with different types of approximations on dead time and the other on desired closed-loop specifications (i.e., specified forward transfer function). The method of handling dead time in the IMC type of design is important especially for systems with large D/tau ratios. A systematic approach was followed to evaluate the performance of controllers. The regions of applicability of suitable tuning rules are highlighted and recommendations are also given. It turns out that IMC designed with the Maclaurin series expansion type PID is a better choice for both set point and load changes for systems with D/tau greater than 1. For systems with D/tau less than 1, the desired closed-loop specification approach is favored.

  11. Closed-Loop Control of Chemical Injection Rate for a Direct Nozzle Injection System

    PubMed Central

    Cai, Xiang; Walgenbach, Martin; Doerpmond, Malte; Schulze Lammers, Peter; Sun, Yurui

    2016-01-01

    To realize site-specific and variable-rate application of agricultural pesticides, accurately metering and controlling the chemical injection rate is necessary. This study presents a prototype of a direct nozzle injection system (DNIS) by which chemical concentration transport lag was greatly reduced. In this system, a rapid-reacting solenoid valve (RRV) was utilized for injecting chemicals, driven by a pulse-width modulation (PWM) signal at 100 Hz, so with varying pulse width the chemical injection rate could be adjusted. Meanwhile, a closed-loop control strategy, proportional-integral-derivative (PID) method, was applied for metering and stabilizing the chemical injection rate. In order to measure chemical flow rates and input them into the controller as a feedback in real-time, a thermodynamic flowmeter that was independent of chemical viscosity was used. Laboratory tests were conducted to assess the performance of DNIS and PID control strategy. Due to the nonlinear input–output characteristics of the RRV, a two-phase PID control process obtained better effects as compared with single PID control strategy. Test results also indicated that the set-point chemical flow rate could be achieved within less than 4 s, and the output stability was improved compared to the case without control strategy. PMID:26805833

  12. PINOID AGC kinases are necessary for phytochrome-mediated enhancement of hypocotyl phototropism in Arabidopsis.

    PubMed

    Haga, Ken; Hayashi, Ken-ichiro; Sakai, Tatsuya

    2014-11-01

    Several members of the AGCVIII kinase subfamily, which includes PINOID (PID), PID2, and WAVY ROOT GROWTH (WAG) proteins, have previously been shown to phosphorylate PIN-FORMED (PIN) auxin transporters and control the auxin flow in plants. PID has been proposed as a key component of the phototropin signaling pathway that induces phototropic responses, although the responses were not significantly impaired in the pid single and pid wag1 wag2 triple mutants. This raises questions about the functional roles of the PID family in phototropic responses. Here, we investigated hypocotyl phototropism in the pid pid2 wag1 wag2 quadruple mutant in detail to clarify the roles of the PID family in Arabidopsis (Arabidopsis thaliana). The pid quadruple mutants exhibited moderate responses in continuous light-induced phototropism with a decrease in growth rates of hypocotyls and normal responses in pulse-induced phototropism. However, they showed serious defects in enhancements of pulse-induced phototropic curvatures and lateral fluorescent auxin transport by red light pretreatment. Red light pretreatment significantly reduced the expression level of PID, and the constitutive expression of PID prevented pulse-induced phototropism, irrespective of red light pretreatment. This suggests that the PID family plays a significant role in phytochrome-mediated phototropic enhancement but not the phototropin signaling pathway. Red light treatment enhanced the intracellular accumulation of PIN proteins in response to the vesicle-trafficking inhibitor brefeldin A in addition to increasing their expression levels. Taken together, these results suggest that red light preirradiation enhances phototropic curvatures by up-regulation of PIN proteins, which are not being phosphorylated by the PID family. © 2014 American Society of Plant Biologists. All Rights Reserved.

  13. PINOID AGC Kinases Are Necessary for Phytochrome-Mediated Enhancement of Hypocotyl Phototropism in Arabidopsis1[W][OPEN

    PubMed Central

    Haga, Ken; Hayashi, Ken-ichiro; Sakai, Tatsuya

    2014-01-01

    Several members of the AGCVIII kinase subfamily, which includes PINOID (PID), PID2, and WAVY ROOT GROWTH (WAG) proteins, have previously been shown to phosphorylate PIN-FORMED (PIN) auxin transporters and control the auxin flow in plants. PID has been proposed as a key component of the phototropin signaling pathway that induces phototropic responses, although the responses were not significantly impaired in the pid single and pid wag1 wag2 triple mutants. This raises questions about the functional roles of the PID family in phototropic responses. Here, we investigated hypocotyl phototropism in the pid pid2 wag1 wag2 quadruple mutant in detail to clarify the roles of the PID family in Arabidopsis (Arabidopsis thaliana). The pid quadruple mutants exhibited moderate responses in continuous light-induced phototropism with a decrease in growth rates of hypocotyls and normal responses in pulse-induced phototropism. However, they showed serious defects in enhancements of pulse-induced phototropic curvatures and lateral fluorescent auxin transport by red light pretreatment. Red light pretreatment significantly reduced the expression level of PID, and the constitutive expression of PID prevented pulse-induced phototropism, irrespective of red light pretreatment. This suggests that the PID family plays a significant role in phytochrome-mediated phototropic enhancement but not the phototropin signaling pathway. Red light treatment enhanced the intracellular accumulation of PIN proteins in response to the vesicle-trafficking inhibitor brefeldin A in addition to increasing their expression levels. Taken together, these results suggest that red light preirradiation enhances phototropic curvatures by up-regulation of PIN proteins, which are not being phosphorylated by the PID family. PMID:25281709

  14. Further Studies on the Effect of SiN x Refractive Index and Emitter Sheet Resistance on Potential-Induced Degradation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, Jaewon; Dauksher, Bill; Bowden, Stuart

    We present the impacts of silicon nitride (SiNx) antireflection coating refractive index and emitter sheet resistance on potential-induced degradation of the shunting type (PID-s). Previously, it has been shown that the cell becomes more PID-s-susceptible as the refractive index decreases or the emitter sheet resistance increases. To verify the effect of refractive index on PID-s, we fabricated cells with varying SiN x refractive index (1.87, 1.94, 2.05) on typical p-type base solar cells with ~60 Ω/sq emitters. However, none of these cells showed output power degradation, regardless of the refractive index. Further investigation of the emitter showed that the PID-smore » was suppressed at ~60 Ω/sq due to the extremely high surface phosphorus concentration (6 x 10 21 cm -3), as measured by secondary ion mass spectrometry. Furthermore, PID-s was observed on cells possessing a high emitter sheet resistance (~80 Ω/sq). In conclusion, the emitter surface phosphorus concentration plays an important role in determining PID-s susceptibility.« less

  15. Further Studies on the Effect of SiN x Refractive Index and Emitter Sheet Resistance on Potential-Induced Degradation

    DOE PAGES

    Oh, Jaewon; Dauksher, Bill; Bowden, Stuart; ...

    2017-01-11

    We present the impacts of silicon nitride (SiNx) antireflection coating refractive index and emitter sheet resistance on potential-induced degradation of the shunting type (PID-s). Previously, it has been shown that the cell becomes more PID-s-susceptible as the refractive index decreases or the emitter sheet resistance increases. To verify the effect of refractive index on PID-s, we fabricated cells with varying SiN x refractive index (1.87, 1.94, 2.05) on typical p-type base solar cells with ~60 Ω/sq emitters. However, none of these cells showed output power degradation, regardless of the refractive index. Further investigation of the emitter showed that the PID-smore » was suppressed at ~60 Ω/sq due to the extremely high surface phosphorus concentration (6 x 10 21 cm -3), as measured by secondary ion mass spectrometry. Furthermore, PID-s was observed on cells possessing a high emitter sheet resistance (~80 Ω/sq). In conclusion, the emitter surface phosphorus concentration plays an important role in determining PID-s susceptibility.« less

  16. Investigating the Personality Inventory for DSM-5 using self and spouse reports.

    PubMed

    Jopp, Andrew M; South, Susan C

    2015-04-01

    Two new clinical tools, the Personality Inventory for DSM-5 (PID-5) and its informant report version, the PID-5-IRF, were developed to assess personality pathology as described by the new trait-based model within Section III of DSM-5. The current study used both self and spousal reports to evaluate agreement between the PID-5 and the PID-5-IRF and to determine the extent to which these measures capture personality pathology as conceptualized in Section II of DSM-5. A nonclinical sample (N = 96 individuals) of recently married couples completed the self-report PID-5, the PID-5-IRF, and the SNAP-2 to assess self-reported DSM-IV PD criteria. Analyses found good to excellent agreement between spousal reports on the PID-5 and the PID-5-IRF for facets in the negative affectivity, detachment, and antagonism domains. In addition, both the PID-5 and the PID-5-IRF each individually accounted for a significant proportion of variance in self-reported DSM-IV PD criteria. Implications for the present findings are discussed.

  17. Mutations in CsPID encoding a Ser/Thr protein kinase are responsible for round leaf shape in cucumber (Cucumis sativus L.).

    PubMed

    Zhang, Chaowen; Chen, Feifan; Zhao, Ziyao; Hu, Liangliang; Liu, Hanqiang; Cheng, Zhihui; Weng, Yiqun; Chen, Peng; Li, Yuhong

    2018-06-01

    Two round-leaf mutants, rl-1 and rl-2, were identified from EMS-induced mutagenesis. High throughput sequencing and map-based cloning suggested CsPID encoding a Ser/Thr protein kinase as the most possible candidate for rl-1. Rl-2 was allelic to Rl-1. Leaf shape is an important plant architecture trait that is affected by plant hormones, especially auxin. In Arabidopsis, PINOID (PID), a regulator for the auxin polar transporter PIN (PIN-FORMED) affects leaf shape formation, but this function of PID in crop plants has not been well studied. From an EMS mutagenesis population, we identified two round-leaf (rl) mutants, C356 and C949. Segregation analysis suggested that both mutations were controlled by single recessive genes, rl-1 and rl-2, respectively. With map-based cloning, we show that CsPID as the candidate gene of rl-1; a non-synonymous SNP in the second exon of CsPID resulted in an amino acid substitution and the round leaf phenotype. As compared in the wild type plant, CsPID had significantly lower expression in the root, leaf and female flowers in C356, which may result in the less developed roots, round leaves and abnormal female flowers, respectively in the rl-1 mutant. Among the three copies of PID genes, CsPID, CsPID2 and CSPID2L (CsPID2-like) in the cucumber genome, CsPID was the only one with significantly differential expression in adult leaves between WT and C356 suggesting CsPID plays a main role in leaf shape formation. The rl-2 mutation in C949 was also cloned, which was due to another SNP in a nearby location of rl-1 in the same CsPID gene. The two round leaf mutants and the work presented herein provide a good foundation for understanding the molecular mechanisms of CsPID in cucumber leaf development.

  18. Fractional System Identification: An Approach Using Continuous Order-Distributions

    NASA Technical Reports Server (NTRS)

    Hartley, Tom T.; Lorenzo, Carl F.

    1999-01-01

    This paper discusses the identification of fractional- and integer-order systems using the concept of continuous order-distribution. Based on the ability to define systems using continuous order-distributions, it is shown that frequency domain system identification can be performed using least squares techniques after discretizing the order-distribution.

  19. Prompt isothermal decay properties of the Sr4Al14O25 co-doped with Eu2+ and Dy3+ persistent luminescent phosphor

    NASA Astrophysics Data System (ADS)

    Asal, Eren Karsu; Polymeris, George S.; Gultekin, Serdar; Kitis, George

    2018-06-01

    Thermoluminescence (TL) techniques are very useful in the research of the persistent Luminescence (PL) phosphors research. It gives information about the existence of energy levels within the forbidden band, its activation energy, kinetic order, lifetime etc. The TL glow curve of Sr4Al14O25 :Eu2+,Dy3+ persistent phosphor, consists of two well separated glow peaks. The TL techniques used to evaluate activation energy were the initial rise, prompt isothermal decay (PID) of TL of each peak at elevated temperatures and the glow - curve fitting. The behavior of the PID curves of the two peak is very different. According to the results of the PID procedure and the subsequent data analysis it is suggested that the mechanism behind the low temperature peak is a delocalized transition. On the other hand the mechanism behind the high temperature peak is localized transition involving a tunneling recombination between electron trap and luminescence center.

  20. The psychometric properties of the Portuguese version of the Personality Inventory for DSM-5.

    PubMed

    Pires, Rute; Sousa Ferreira, Ana; Guedes, David

    2017-10-01

    The DSM-5 Section III proposes a hybrid dimensional-categorical model of conceptualizing personality and its disorders that includes assessment of impairments in personality functioning (criterion A) and maladaptive personality traits (criterion B). The Personality Inventory for the DSM-5 is a new dimensional tool, composed of 220 items organized into 25 facets that delineate five higher order domains of clinically relevant personality differences, and was developed to operationalize the DSM-5 model of pathological personality traits. The current studies address the internal consistency (study 1), the test-retest reliability (study 2) and the criterion validity (studies 3 and 4) of the Portuguese version of the PID-5 in samples of native speaking psychology students. Results indicated good internal consistency reliabilities and good temporal stability reliabilities for the majority of the PID-5 traits. The correlational pattern of the PID-5 traits with two measures of personality was in accordance with theoretical expectations and showed its concurrent validity. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  1. Simulation comparison of proportional integral derivative and fuzzy logic in controlling AC-DC buck boost converter

    NASA Astrophysics Data System (ADS)

    Faisal, A.; Hasan, S.; Suherman

    2018-03-01

    AC-DC converter is widely used in the commercial industry even for daily purposes. The AC-DC converter is used to convert AC voltage into DC. In order to obtain the desired output voltage, the converter usually has a controllable regulator. This paper discusses buck boost regulator with a power MOSFET as switching component which is adjusted based on the duty cycle of pulse width modulation (PWM). The main problems of the buck boost converter at start up are the high overshoot, the long peak time and rise time. This paper compares the effectiveness of two control techniques: proportional integral derivative (PID) and fuzzy logic control in controlling the buck boost converter through simulations. The results show that the PID is more sensitive to voltage change than fuzzy logic. However, PID generates higher overshoot, long peak time and rise time. On the other hand, fuzzy logic generates no overshoot and shorter rise time.

  2. Primary immunodeficiency diseases: a 30-year patient registry from the referral center for primary immunodeficiencies in Greece.

    PubMed

    Michos, Athanasios; Raptaki, Maria; Tantou, Sofia; Tzanoudaki, Marianna; Spanou, Kleopatra; Liatsis, Manolis; Constantinidou, Nikki; Paschali, Evangelia; Varela, Ioanna; Moraloglou, Olga; Bakoula, Chryssa; Kanariou, Maria

    2014-10-01

    Primary Immunodeficiencies (PID) represent a group of heterogeneous immune diseases with important biological significance. We reviewed the records of children diagnosed with PID in the Referral Center for PID in our country in order to describe the epidemiological, clinical and laboratory characteristics of immunodeficient patients. During a 30-year period, 147 patients (101 males, 68.7 %), with a mean age of 6.5 years at the time of diagnosis, were diagnosed with PID. The most prevalent diagnoses of PID were: "Combined Immunodeficiency" in 46 (31.3 %) patients, "Well-defined immunodeficiency syndrome" in 35 (23.1 %) patients, "Predominantly antibody deficiency" in 30 (20.4 %) patients and "Congenital defect of phagocyte function or both" in 28 (19 %) patients. There was a higher prevalence of males with "Combined immunodeficiency" (p < 0.033) and "Predominantly antibody deficiency" (p < 0.02) compared to females. The median age of children at the onset of symptoms and at the time of diagnosis was 0.5y (IQR: 0.1-2.5) and 2y (IQR: 0.6-7.2), respectively. The median diagnostic delay was 0.9y (IQR: 0.2-4.8). This period was shorter for patients with "Combined immunodeficiency" [median 0.3y (IQR: 0.1-1)], and longer for those with "Predominantly antibody deficiency" [median 3.2y (IQR: 0.2-5.9) or "Disease of immune dysregulation" [median 3.2y (IQR: 0.1-6.6)]. Comparing the rates in our population with those of the European Registry (ESID), the rates of "Combined immunodeficiencies", "Well-defined syndromes" and "Congenital birth defects and/or function of phagocytes" were significantly higher in this study (p <0,001). PID registry analysis improves knowledge in the field of Immunology and enhances awareness, early detection, diagnosis, and management of this rare but significant group of diseases.

  3. Ordering kinetics in the long-period superlattice alloy Cu0.79 Pd0.21

    NASA Astrophysics Data System (ADS)

    Wang, X.; Mainville, J.; Ludwig, K.; Flament, X.; Finel, A.; Caudron, R.

    2005-07-01

    The kinetics of long-period superlattice (LPS) formation from the disordered state has been examined in a Cu0.79Pd0.21 alloy that exhibits a one-dimensional LPS ordered state. Time-resolved x-ray scattering shows that, following a rapid temperature quench from the disordered state into the LPS region of the phase diagram, the satellite peaks initially grow more quickly than do the central integer-order superlattice peaks. During this process, the satellite peak position, which is inversely related to the average modulation wavelength 2M , initially decreases rapidly, then reaches a minimum and relaxes slowly back toward its new equilibrium position. In the later stages of the LPS formation process, the satellite and central integer-order superlattice peaks narrow in a manner consistent with t1/2 domain coarsening. A simple stochastic model of the partially ordered structure was developed to better understand the relationships between peak widths.

  4. Fractional-order positive position feedback compensator for active vibration control of a smart composite plate

    NASA Astrophysics Data System (ADS)

    Marinangeli, L.; Alijani, F.; HosseinNia, S. Hassan

    2018-01-01

    In this paper, Active Vibration Control (AVC) of a rectangular carbon fibre composite plate with free edges is presented. The plate is subjected to out-of-plane excitation by a modal vibration exciter and controlled by Macro Fibre Composite (MFC) transducers. Vibration measurements are performed by using a Laser Doppler Vibrometer (LDV) system. A fractional-order Positive Position Feedback (PPF) compensator is proposed, implemented and compared to the standard integer-order PPF. MFC actuator and sensor are positioned on the plate based on maximal modal strain criterion, so as to control the second natural mode of the plate. Both integer and fractional-order PPF allowed for the effective control of the second mode of vibration. However, the newly proposed fractional-order controller is found to be more efficient in achieving the same performance with less actuation voltage. Moreover, it shows promising performance in reducing spillover effect due to uncontrolled modes.

  5. Model Free iPID Control for Glycemia Regulation of Type-1 Diabetes.

    PubMed

    MohammadRidha, Taghreed; Ait-Ahmed, Mourad; Chaillous, Lucy; Krempf, Michel; Guilhem, Isabelle; Poirier, Jean-Yves; Moog, Claude H

    2018-01-01

    The objective is to design a fully automated glycemia controller of Type-1 Diabetes (T1D) in both fasting and postprandial phases on a large number of virtual patients. A model-free intelligent proportional-integral-derivative (iPID) is used to infuse insulin. The feasibility of iPID is tested in silico on two simulators with and without measurement noise. The first simulator is derived from a long-term linear time-invariant model. The controller is also validated on the UVa/Padova metabolic simulator on 10 adults under 25 runs/subject for noise robustness test. It was shown that without measurement noise, iPID mimicked the normal pancreatic secretion with a relatively fast reaction to meals as compared to a standard PID. With the UVa/Padova simulator, the robustness against CGM noise was tested. A higher percentage of time in target was obtained with iPID as compared to standard PID with reduced time spent in hyperglycemia. Two different T1D simulators tests showed that iPID detects meals and reacts faster to meal perturbations as compared to a classic PID. The intelligent part turns the controller to be more aggressive immediately after meals without neglecting safety. Further research is suggested to improve the computation of the intelligent part of iPID for such systems under actuator constraints. Any improvement can impact the overall performance of the model-free controller. The simple structure iPID is a step for PID-like controllers since it combines the classic PID nice properties with new adaptive features.

  6. PID1 (NYGGF4), a new growth-inhibitory gene in embryonal brain tumors and gliomas

    PubMed Central

    Erdreich-Epstein, Anat; Robison, Nathan; Ren, Xiuhai; Zhou, Hong; Xu, Jingying; Davidson, Tom B.; Schur, Mathew; Gilles, Floyd H.; Ji, Lingyun; Malvar, Jemily; Shackleford, Gregory M.; Margol, Ashley S.; Krieger, Mark D.; Judkins, Alexander R.; Jones, David T.W.; Pfister, Stefan; Kool, Marcel; Sposto, Richard; Asgharazadeh, Shahab

    2014-01-01

    Purpose We present here the first report of PID1 (Phosphotyrosine Interaction Domain containing 1; NYGGF4) in cancer. PID1 was identified in 2006 as a gene that modulates insulin signaling and mitochondrial function in adipocytes and muscle cells. Experimental Design and Results Using four independent medulloblastoma datasets, we show that mean PID1 mRNA levels were lower in unfavorable medulloblastomas (Groups 3 and 4, and anaplastic histology) compared with favorable medulloblastomas (SHH and WNT groups, and desmoplastic/nodular histology) and with fetal cerebellum. In two large independent glioma datasets PID1 mRNA was lower in glioblastomas (GBMs), the most malignant gliomas, compared to other astrocytomas, oligodendrogliomas and non-tumor brains. Neural and proneural GBM subtypes had higher PID1 mRNA compared to classical and mesenchymal GBM. Importantly, overall survival and radiation-free progression-free survival were longer in medulloblastoma patients with higher PID1 mRNA (univariate and multivariate analyses). Higher PID1 mRNA also correlated with longer overall survival in glioma and GBM patients. In cell culture, overexpression of PID1 inhibited colony formation in medulloblastoma, atypical teratoid rhabdoid tumor (ATRT) and GBM cell lines. Increasing PID1 also increased cell death and apoptosis, inhibited proliferation, induced mitochondrial depolarization, and decreased serum-mediated phosphorylation of AKT and ERK in medulloblastoma, ATRT and/or GBM cell lines, whereas siRNA to PID1 diminished mitochondrial depolarization. Conclusions These data are the first to link PID1 to cancer and suggest that PID1 may have a tumor inhibitory function in these pediatric and adult brain tumors. PMID:24300787

  7. Absence of even-integer ζ-function values in Euclidean physical quantities in QCD

    NASA Astrophysics Data System (ADS)

    Jamin, Matthias; Miravitllas, Ramon

    2018-04-01

    At order αs4 in perturbative quantum chromodynamics, even-integer ζ-function values are present in Euclidean physical correlation functions like the scalar quark correlation function or the scalar gluonium correlator. We demonstrate that these contributions cancel when the perturbative expansion is expressed in terms of the so-called C-scheme coupling αˆs which has recently been introduced in Ref. [1]. It is furthermore conjectured that a ζ4 term should arise in the Adler function at order αs5 in the MS ‾-scheme, and that this term is expected to disappear in the C-scheme as well.

  8. PINOID functions in root phototropism as a negative regulator

    PubMed Central

    Haga, Ken; Sakai, Tatsuya

    2015-01-01

    The PINOID (PID) family, which belongs to AGCVIII kinases, is known to be involved in the regulation of auxin efflux transporter PIN-FORMED (PIN) proteins through changes in the phosphorylation status. Recently, we demonstrated that the PID family is necessary for phytochrome-mediated phototropic enhancement in Arabidopsis hypocotyls and that the downregulation of PID expression by red-light pretreatment results in the promotion of the PIN-mediated auxin gradient during phototropic responses. However, whether PID participates in root phototropism in Arabidopsis seedlings has not been well studied. Here, we demonstrated that negative root phototropic responses are enhanced in the pid quadruple mutant and are severely impaired in transgenic plants expressing PID constitutively. The results indicate that the PID family functions in a negative root phototropism as a negative regulator. On the other hand, analysis with PID fused to a yellow fluorescent protein, VENUS, showed that unilateral blue-light irradiation causes a lower accumulation of PID proteins on the shaded side than on the irradiated side. This result suggests that the blue-light-mediated asymmetrical distribution of PID proteins may be one of the critical responses in phototropin-mediated signals during a negative root phototropism. Alternatively, such a transverse gradient of PID proteins may result from gravitropic stimulation produced by phototropic bending. PMID:26039488

  9. PINOID functions in root phototropism as a negative regulator.

    PubMed

    Haga, Ken; Sakai, Tatsuya

    2015-01-01

    The PINOID (PID) family, which belongs to AGCVIII kinases, is known to be involved in the regulation of auxin efflux transporter PIN-formed (PIN) proteins through changes in the phosphorylation status. Recently, we demonstrated that the PID family is necessary for phytochrome-mediated phototropic enhancement in Arabidopsis hypocotyls and that the downregulation of PID expression by red-light pretreatment results in the promotion of the PIN-mediated auxin gradient during phototropic responses. However, whether PID participates in root phototropism in Arabidopsis seedlings has not been well studied. Here, we demonstrated that negative root phototropic responses are enhanced in the pid quadruple mutant and are severely impaired in transgenic plants expressing PID constitutively. The results indicate that the PID family functions in a negative root phototropism as a negative regulator. On the other hand, analysis with PID fused to a yellow fluorescent protein, VENUS, showed that unilateral blue-light irradiation causes a lower accumulation of PID proteins on the shaded side than on the irradiated side. This result suggests that the blue-light-mediated asymmetrical distribution of PID proteins may be one of the critical responses in phototropin-mediated signals during a negative root phototropism. Alternatively, such a transverse gradient of PID proteins may result from gravitropic stimulation produced by phototropic bending.

  10. Mixed integer simulation optimization for optimal hydraulic fracturing and production of shale gas fields

    NASA Astrophysics Data System (ADS)

    Li, J. C.; Gong, B.; Wang, H. G.

    2016-08-01

    Optimal development of shale gas fields involves designing a most productive fracturing network for hydraulic stimulation processes and operating wells appropriately throughout the production time. A hydraulic fracturing network design-determining well placement, number of fracturing stages, and fracture lengths-is defined by specifying a set of integer ordered blocks to drill wells and create fractures in a discrete shale gas reservoir model. The well control variables such as bottom hole pressures or production rates for well operations are real valued. Shale gas development problems, therefore, can be mathematically formulated with mixed-integer optimization models. A shale gas reservoir simulator is used to evaluate the production performance for a hydraulic fracturing and well control plan. To find the optimal fracturing design and well operation is challenging because the problem is a mixed integer optimization problem and entails computationally expensive reservoir simulation. A dynamic simplex interpolation-based alternate subspace (DSIAS) search method is applied for mixed integer optimization problems associated with shale gas development projects. The optimization performance is demonstrated with the example case of the development of the Barnett Shale field. The optimization results of DSIAS are compared with those of a pattern search algorithm.

  11. Interplay of Hofstadter and quantum Hall states in bilayer graphene

    NASA Astrophysics Data System (ADS)

    Spanton, Eric M.; Zibrov, Alexander A.; Zhou, Haoxin; Taniguchi, Takashi; Watanabe, Kenji; Young, Andrea

    Electron interactions in ultraclean systems such as graphene lead to the fractional quantum Hall effect in an applied magnetic field. Long wavelength periodic potentials from a moiré pattern in aligned boron nitride-graphene heterostructures may compete with such interactions and favor spatially ordered states (e.g. Wigner crystals orcharge density waves). To investigate this competition, we studied the bulk phase diagram of asymmetrically moiré-coupled bilayer graphene via multi-terminal magnetocapacitance measurements at ultra-high magnetic fields. Two quantum numbers characterize energy gaps in this regime: t, which indexes the Bloch bands, and s, which indexes the Landau level. Similar to past experiments, we observe the conventional integer and fractional quantum Hall gaps (t = 0), integer Hofstadter gaps (integer s and integer t ≠ 0), and fractional Bloch states associated with an expanded superlattice unit cell (fractional s and integer t). Additionally, we find states with fractional values for both s and t. Measurement of the capacitance matrix shows that these states occur on the layer exposed to the strong periodic potential. We discuss the results in terms of possible fractional quantum hall states unique to periodically modulated systems.

  12. Design of high precision temperature control system for TO packaged LD

    NASA Astrophysics Data System (ADS)

    Liang, Enji; Luo, Baoke; Zhuang, Bin; He, Zhengquan

    2017-10-01

    Temperature is an important factor affecting the performance of TO package LD. In order to ensure the safe and stable operation of LD, a temperature control circuit for LD based on PID technology is designed. The MAX1978 and an external PID circuit are used to form a control circuit that drives the thermoelectric cooler (TEC) to achieve control of temperature and the external load can be changed. The system circuit has low power consumption, high integration and high precision,and the circuit can achieve precise control of the LD temperature. Experiment results show that the circuit can achieve effective and stable control of the laser temperature.

  13. Methodologies for Root Locus and Loop Shaping Control Design with Comparisons

    NASA Technical Reports Server (NTRS)

    Kopasakis, George

    2017-01-01

    This paper describes some basics for the root locus controls design method as well as for loop shaping, and establishes approaches to expedite the application of these two design methodologies to easily obtain control designs that meet requirements with superior performance. The two design approaches are compared for their ability to meet control design specifications and for ease of application using control design examples. These approaches are also compared with traditional Proportional Integral Derivative (PID) control in order to demonstrate the limitations of PID control. Robustness of these designs is covered as it pertains to these control methodologies and for the example problems.

  14. [Nationwide survey on pediatric infectious disease organisation and antibiotic management in French hospitals].

    PubMed

    Angoulvant, F; Dubos, F; Cohen, R; Martinot, A

    2015-05-01

    Skills in pediatric infectious disease (PID) and antibiotic management are of critical importance in hospitals. This nationwide survey aimed to assess the characteristics, training, and tasks of PID consultants in French hospitals. The management of PID and antibiotic therapy was also analyzed in hospitals lacking PID consultants. An electronic survey linked to a dedicated website was sent to French hospitals with a pediatric department in June 2012. In hospitals where PID consultants were available, they were asked to answer the questionnaire. In hospitals lacking PID consultants, pediatricians were asked to send the questionnaire to their infectious disease consultant, if available. A total of 86 individual responses were received from 76 hospitals (including 26 academic hospitals). The existence of a PID consultant was declared in 53 hospitals. Responses were received from the person claiming to be "the" or "one of the" PID consultants in 46 cases, representing 39 centers. PID consultants had a degree in PID (46%) or antibiotic therapy (37%), or a complementary qualification as a specialist in infectious diseases (13%). The PID consultants worked in departments of general pediatrics (61%) and emergency medicine (15%), or neonatology (15%). They were involved in the Nosocomial Infection Prevention Committee (43%) or the Antimicrobial Therapy Committee (63%) and had teaching activities (65%). There was a specific unit with a PID label in 10% of the 39 centers reporting at least one consultant and consultations of infectious diseases took place in 28%. PID consultants are rare. Their important role in patient care should be recognized. Efforts should focus on recruiting and training such specialists. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. PIPS-SBB: A Parallel Distributed-Memory Branch-and-Bound Algorithm for Stochastic Mixed-Integer Programs

    DOE PAGES

    Munguia, Lluis-Miquel; Oxberry, Geoffrey; Rajan, Deepak

    2016-05-01

    Stochastic mixed-integer programs (SMIPs) deal with optimization under uncertainty at many levels of the decision-making process. When solved as extensive formulation mixed- integer programs, problem instances can exceed available memory on a single workstation. In order to overcome this limitation, we present PIPS-SBB: a distributed-memory parallel stochastic MIP solver that takes advantage of parallelism at multiple levels of the optimization process. We also show promising results on the SIPLIB benchmark by combining methods known for accelerating Branch and Bound (B&B) methods with new ideas that leverage the structure of SMIPs. Finally, we expect the performance of PIPS-SBB to improve furthermore » as more functionality is added in the future.« less

  16. Logic integer programming models for signaling networks.

    PubMed

    Haus, Utz-Uwe; Niermann, Kathrin; Truemper, Klaus; Weismantel, Robert

    2009-05-01

    We propose a static and a dynamic approach to model biological signaling networks, and show how each can be used to answer relevant biological questions. For this, we use the two different mathematical tools of Propositional Logic and Integer Programming. The power of discrete mathematics for handling qualitative as well as quantitative data has so far not been exploited in molecular biology, which is mostly driven by experimental research, relying on first-order or statistical models. The arising logic statements and integer programs are analyzed and can be solved with standard software. For a restricted class of problems the logic models reduce to a polynomial-time solvable satisfiability algorithm. Additionally, a more dynamic model enables enumeration of possible time resolutions in poly-logarithmic time. Computational experiments are included.

  17. PINOID kinase regulates root gravitropism through modulation of PIN2-dependent basipetal auxin transport in Arabidopsis.

    PubMed

    Sukumar, Poornima; Edwards, Karin S; Rahman, Abidur; Delong, Alison; Muday, Gloria K

    2009-06-01

    Reversible protein phosphorylation is a key regulatory mechanism governing polar auxin transport. We characterized the auxin transport and gravitropic phenotypes of the pinoid-9 (pid-9) mutant of Arabidopsis (Arabidopsis thaliana) and tested the hypothesis that phosphorylation mediated by PID kinase and dephosphorylation regulated by the ROOTS CURL IN NAPHTHYLPHTHALAMIC ACID1 (RCN1) protein might antagonistically regulate root auxin transport and gravity response. Basipetal indole-3-acetic acid transport and gravitropism are reduced in pid-9 seedlings, while acropetal transport and lateral root development are unchanged. Treatment of wild-type seedlings with the protein kinase inhibitor staurosporine phenocopies the reduced auxin transport and gravity response of pid-9, while pid-9 is resistant to inhibition by staurosporine. Staurosporine and the phosphatase inhibitor, cantharidin, delay the asymmetric expression of DR5revGFP (green fluorescent protein) at the root tip after gravistimulation. Gravity response defects of rcn1 and pid-9 are partially rescued by treatment with staurosporine and cantharidin, respectively. The pid-9 rcn1 double mutant has a more rapid gravitropic response than rcn1. These data are consistent with a reciprocal regulation of gravitropism by RCN1 and PID. Furthermore, the effect of staurosporine is lost in pinformed2 (pin2). Our data suggest that reduced PID kinase function inhibits gravitropism and basipetal indole-3-acetic acid transport. However, in contrast to PID overexpression studies, we observed wild-type asymmetric membrane distribution of the PIN2 protein in both pid-9 and wild-type root tips, although PIN2 accumulates in endomembrane structures in pid-9 roots. Similarly, staurosporine-treated plants expressing a PIN2GFP fusion exhibit endomembrane accumulation of PIN2GFP, but no changes in membrane asymmetries were detected. Our data suggest that PID plays a limited role in root development; loss of PID activity alters auxin transport and gravitropism without causing an obvious change in cellular polarity.

  18. Primary Immunodeficiencies: “New” Disease in an Old Country

    PubMed Central

    Lee, Pamela P W; Lau, Yu-Lung

    2009-01-01

    Primary immunodeficiency disorders (PIDs) are rare inborn errors of the immune system. Patients with PIDs are unique models that exemplify the functional and phenotypic consequences of various immune defects underlying infections, autoimmunity, lymphoproliferation, allergy and cancer. Over 150 PID syndromes were characterized in the past 60 years, with an ever growing list of new entities being discovered. Because of their rarity, multi-center collaboration for pooled data analysis and molecular studies is important to gain meaningful insights into the phenotypic and genetic diversities of PIDs. In this article, we summarize our research findings on PIDs in Chinese population in the past 20 years. Close collaboration among various immunology centers, cross-referrals and systematic data analysis constitute the foundation for research on PIDs. Future directions include establishment of a national PID registry, raising awareness of PIDs and securing sufficient resources for patient care and scientific research. PMID:20003815

  19. Improved fuzzy PID controller design using predictive functional control structure.

    PubMed

    Wang, Yuzhong; Jin, Qibing; Zhang, Ridong

    2017-11-01

    In conventional PID scheme, the ensemble control performance may be unsatisfactory due to limited degrees of freedom under various kinds of uncertainty. To overcome this disadvantage, a novel PID control method that inherits the advantages of fuzzy PID control and the predictive functional control (PFC) is presented and further verified on the temperature model of a coke furnace. Based on the framework of PFC, the prediction of the future process behavior is first obtained using the current process input signal. Then, the fuzzy PID control based on the multi-step prediction is introduced to acquire the optimal control law. Finally, the case study on a temperature model of a coke furnace shows the effectiveness of the fuzzy PID control scheme when compared with conventional PID control and fuzzy self-adaptive PID control. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Observation of high-order quantum resonances in the kicked rotor.

    PubMed

    Kanem, J F; Maneshi, S; Partlow, M; Spanner, M; Steinberg, A M

    2007-02-23

    Quantum resonances in the kicked rotor are characterized by a dramatically increased energy absorption rate, in stark contrast to the momentum localization generally observed. These resonances occur when the scaled Planck's constant Planck's [over ]=r/s 4pi, for any integers r and s. However, only the variant Planck's [over ]=r2pi resonances are easily observable. We have observed high-order quantum resonances (s>2) utilizing a sample of low energy, noncondensed atoms and a pulsed optical standing wave. Resonances are observed for variant Planck's [over ]=r/16 4pi for integers r=2-6. Quantum numerical simulations suggest that our observation of high-order resonances indicate a larger coherence length (i.e., coherence between different wells) than expected from an initially thermal atomic sample.

  1. Extending and implementing the Persistent ID pillars

    NASA Astrophysics Data System (ADS)

    Car, Nicholas; Golodoniuc, Pavel; Klump, Jens

    2017-04-01

    The recent double decade anniversary of scholarly persistent identifier use has triggered journal special editions such as "20 Years of Persistent Identifiers". For such a publication, it is apt to consider the longevity of some persistent identifier (PID) mechanisms (Digital Object Identifiers) and the partial disappearance of others (Life Sciences IDs). We have previously postulated a set of "PID Pillars" [1] which are design principles aimed at ensuring PIDs can survive technology and social change and thus persist for the long term that we have drawn from our observations of PIDs at work over many years. The principles: describe how to ensure identifiers' system and organisation independence; codify the delivery of essential PID system functions; mandate a separation of PID functions from data delivery mechanisms; and require generation of policies detailing how change is handled. In this presentation, first we extend on our previous work of introducing the pillars by refining their descriptions, giving specific suggestions for each and presenting some work that addresses them. Second, we propose a baseline data model for persistent identifiers that, if used, would assist the separation of PID metadata and PID system functioning. This would allow PID system function specifics to change over time (e.g. resolver services or even resolution protocols) and yet preserve the PIDs themselves. Third, we detail our existing PID system — the PID Service [2] — that partially implements the pillars and describe both its successes and shortcomings. Finally, we describe our planned next-generation system that will aim to use the baseline data model and fully implement the pillars.

  2. Intelligent tuning method of PID parameters based on iterative learning control for atomic force microscopy.

    PubMed

    Liu, Hui; Li, Yingzi; Zhang, Yingxu; Chen, Yifu; Song, Zihang; Wang, Zhenyu; Zhang, Suoxin; Qian, Jianqiang

    2018-01-01

    Proportional-integral-derivative (PID) parameters play a vital role in the imaging process of an atomic force microscope (AFM). Traditional parameter tuning methods require a lot of manpower and it is difficult to set PID parameters in unattended working environments. In this manuscript, an intelligent tuning method of PID parameters based on iterative learning control is proposed to self-adjust PID parameters of the AFM according to the sample topography. This method gets enough information about the output signals of PID controller and tracking error, which will be used to calculate the proper PID parameters, by repeated line scanning until convergence before normal scanning to learn the topography. Subsequently, the appropriate PID parameters are obtained by fitting method and then applied to the normal scanning process. The feasibility of the method is demonstrated by the convergence analysis. Simulations and experimental results indicate that the proposed method can intelligently tune PID parameters of the AFM for imaging different topographies and thus achieve good tracking performance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. New Insights into the Fractional Order Diffusion Equation Using Entropy and Kurtosis.

    PubMed

    Ingo, Carson; Magin, Richard L; Parrish, Todd B

    2014-11-01

    Fractional order derivative operators offer a concise description to model multi-scale, heterogeneous and non-local systems. Specifically, in magnetic resonance imaging, there has been recent work to apply fractional order derivatives to model the non-Gaussian diffusion signal, which is ubiquitous in the movement of water protons within biological tissue. To provide a new perspective for establishing the utility of fractional order models, we apply entropy for the case of anomalous diffusion governed by a fractional order diffusion equation generalized in space and in time. This fractional order representation, in the form of the Mittag-Leffler function, gives an entropy minimum for the integer case of Gaussian diffusion and greater values of spectral entropy for non-integer values of the space and time derivatives. Furthermore, we consider kurtosis, defined as the normalized fourth moment, as another probabilistic description of the fractional time derivative. Finally, we demonstrate the implementation of anomalous diffusion, entropy and kurtosis measurements in diffusion weighted magnetic resonance imaging in the brain of a chronic ischemic stroke patient.

  4. Soft Real-Time PID Control on a VME Computer

    NASA Technical Reports Server (NTRS)

    Karayan, Vahag; Sander, Stanley; Cageao, Richard

    2007-01-01

    microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.

  5. [Researches in immunological responses after burn injury in China].

    PubMed

    Peng, Dai-zhi

    2008-10-01

    For five decades it has been recognized that severe burn injury may precipitate in marked alterations in immune function, resulting in life-threatening systemic infections, sepsis, multiple organ failure, and even death. Extensive and deep burns exert widespread and profound impacts on various cells and molecules of the immune system. The general characteristics of abnormal immune responses following major burns are hyperinflammatory response and hypoimmune response of innate and adaptive immunity. These are recognized as postburn immune dysfunction (PID). The stress reaction, massive necrotic tissue, shock, infection, malnutrition and various therapeutic procedures after burns alter the microenvironment of the immune cells and molecules in which they reside, and consequently result in the changes in immune cells and their secretions in quantity and/or activity, and also aberrant signal transduction in different immune cells. These events constitute the cellular and molecular bases in the pathogenesis of PID. The main clinical consequences of PID include tissue damages and increased susceptibility to opportunistic pathogens caused by refractory inflammation and suppressed adaptive immunity. In order to decrease the morbidity of these lethal complications, efforts to improve the immune dysfunction after burn injury have been made not only at the integral level of etiological factors, but also at the cellular and molecular levels of its mechanisms. In this review, all these above-mentioned aspects of PID are comprehensively discussed.

  6. Potential-induced degradation in photovoltaic modules: a critical review

    DOE PAGES

    Luo, Wei; Khoo, Yong Sheng; Hacke, Peter; ...

    2016-11-21

    Potential-induced degradation (PID) has received considerable attention in recent years due to its detrimental impact on photovoltaic (PV) module performance under field conditions. Both crystalline silicon (c-Si) and thin-film PV modules are susceptible to PID. While extensive studies have already been conducted in this area, the understanding of the PID phenomena is still incomplete and it remains a major problem in the PV industry. Herein, a critical review of the available literature is given to serve as a one-stop source for understanding the current status of PID research. This article also aims to provide an overview of future research pathsmore » to address PID-related issues. This paper consists of three parts. In the first part, the modelling of leakage current paths in the module package is discussed. The PID mechanisms in both c-Si and thin-film PV modules are also comprehensively reviewed. The second part summarizes various test methods to evaluate PV modules for PID. The last part focuses on studies related to PID in the omnipresent p-type c-Si PV modules. The dependence of temperature, humidity and voltage on the progression of PID is examined. Preventive measures against PID at the cell, module and system levels are illustrated. Moreover, PID recovery in standard p-type c-Si PV modules is also studied. Most of the findings from p-type c-Si PV modules are also applicable to other PV module technologies.« less

  7. How effective are the 6 European Society of Immunodeficiency warning signs for primary immunodeficiency disease?

    PubMed

    Arslan, Sevket; Ucar, Ramazan; Caliskaner, Ahmet Zafer; Reisli, Ismail; Guner, Sukru Nail; Sayar, Esra Hazar; Baloglu, Ismail

    2016-02-01

    The European Society of Immunodeficiency (ESID) developed 6 warning signs to promote the awareness of adult primary immunodeficiency disease (PID). To screen adult patients for the presence of PID using these 6 warning signs to determine the effectiveness of this protocol. Questions related to the ESID warning signs for adult PID were added to the standard outpatient clinic file system and asked of 3,510 patients who were admitted to our clinic for any reason. Patients with signs and/or suspicion of PID based on their medical history underwent immunologic investigation. In total, 24 patients were diagnosed as having a PID. The most common reason that patients with PID were admitted was frequent infection (n=18 [75%]), and the most common PID subgroup was common variable immunodeficiency (n=12 [50%]). Twenty patients with PID had at least one positive finding according to the ESID warning signs. Two patients with gastrointestinal concerns and 2 with dermatologic symptoms were also diagnosed as having a PID, although they did not have any of the ESID warning signs. The ESID warning signs do not specify the need for symptoms to diagnose a PIDs and do not include a comprehensive list of all signs and symptoms of PIDs. As a result, more than infection-centric questions are needed to identify adult patients with immunodeficiencies. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  8. Pelvic inflammatory disease.

    PubMed

    Hanna, L; Highleyman, L

    1996-03-01

    Pelvic inflammatory disease (PID) is a generic term relating to a broad range of conditions. The term is used to describe infections of the fallopian tubes, uterus, ovaries, or peritoneum. PID is a potentially life-threatening condition in any woman, but HIV-positive women are at serious risk of severe complications or death. PID is caused when infection-producing organisms spread upwards from the vagina through the cervix to the upper reproductive organs. Untreated sexually transmitted diseases are a leading cause of PID. Consequences include chronic pelvic pain, abdominal abscesses, inflammation of the covering of the liver, sepsis, and death. Sterility may also result from PID. PID is generally treated with a combination of antibiotics, and it is crucial to treat other concurrent infections as well. Early treatment of PID in HIV-positive women is essential.

  9. Capturing the DSM-5 Alternative Personality Disorder Model Traits in the Five-Factor Model's Nomological Net.

    PubMed

    Suzuki, Takakuni; Griffin, Sarah A; Samuel, Douglas B

    2017-04-01

    Several studies have shown structural and statistical similarities between the Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM-5) alternative personality disorder model and the Five-Factor Model (FFM). However, no study to date has evaluated the nomological network similarities between the two models. The relations of the Revised NEO Personality Inventory (NEO PI-R) and the Personality Inventory for DSM-5 (PID-5) with relevant criterion variables were examined in a sample of 336 undergraduate students (M age  = 19.4; 59.8% female). The resulting profiles for each instrument were statistically compared for similarity. Four of the five domains of the two models have highly similar nomological networks, with the exception being FFM Openness to Experience and PID-5 Psychoticism. Further probing of that pair suggested that the NEO PI-R domain scores obscured meaningful similarity between PID-5 Psychoticism and specific aspects and lower-order facets of Openness. The results support the notion that the DSM-5 alternative personality disorder model trait domains represent variants of the FFM domains. Similarities of Openness and Psychoticism domains were supported when the lower-order aspects and facets of Openness domain were considered. The findings support the view that the DSM-5 trait model represents an instantiation of the FFM. © 2015 Wiley Periodicals, Inc.

  10. Interval type-2 fuzzy PID controller for uncertain nonlinear inverted pendulum system.

    PubMed

    El-Bardini, Mohammad; El-Nagar, Ahmad M

    2014-05-01

    In this paper, the interval type-2 fuzzy proportional-integral-derivative controller (IT2F-PID) is proposed for controlling an inverted pendulum on a cart system with an uncertain model. The proposed controller is designed using a new method of type-reduction that we have proposed, which is called the simplified type-reduction method. The proposed IT2F-PID controller is able to handle the effect of structure uncertainties due to the structure of the interval type-2 fuzzy logic system (IT2-FLS). The results of the proposed IT2F-PID controller using a new method of type-reduction are compared with the other proposed IT2F-PID controller using the uncertainty bound method and the type-1 fuzzy PID controller (T1F-PID). The simulation and practical results show that the performance of the proposed controller is significantly improved compared with the T1F-PID controller. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  11. Efficient numerical simulation of non-integer-order space-fractional reaction-diffusion equation via the Riemann-Liouville operator

    NASA Astrophysics Data System (ADS)

    Owolabi, Kolade M.

    2018-03-01

    In this work, we are concerned with the solution of non-integer space-fractional reaction-diffusion equations with the Riemann-Liouville space-fractional derivative in high dimensions. We approximate the Riemann-Liouville derivative with the Fourier transform method and advance the resulting system in time with any time-stepping solver. In the numerical experiments, we expect the travelling wave to arise from the given initial condition on the computational domain (-∞, ∞), which we terminate in the numerical experiments with a large but truncated value of L. It is necessary to choose L large enough to allow the waves to have enough space to distribute. Experimental results in high dimensions on the space-fractional reaction-diffusion models with applications to biological models (Fisher and Allen-Cahn equations) are considered. Simulation results reveal that fractional reaction-diffusion equations can give rise to a range of physical phenomena when compared to non-integer-order cases. As a result, most meaningful and practical situations are found to be modelled with the concept of fractional calculus.

  12. Implementing direct, spatially isolated problems on transputer networks

    NASA Technical Reports Server (NTRS)

    Ellis, Graham K.

    1988-01-01

    Parametric studies were performed on transputer networks of up to 40 processors to determine how to implement and maximize the performance of the solution of problems where no processor-to-processor data transfer is required for the problem solution (spatially isolated). Two types of problems are investigated a computationally intensive problem where the solution required the transmission of 160 bytes of data through the parallel network, and a communication intensive example that required the transmission of 3 Mbytes of data through the network. This data consists of solutions being sent back to the host processor and not intermediate results for another processor to work on. Studies were performed on both integer and floating-point transputers. The latter features an on-chip floating-point math unit and offers approximately an order of magnitude performance increase over the integer transputer on real valued computations. The results indicate that a minimum amount of work is required on each node per communication to achieve high network speedups (efficiencies). The floating-point processor requires approximately an order of magnitude more work per communication than the integer processor because of the floating-point unit's increased computing capacity.

  13. Quantifying commuter exposures to volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Kayne, Ashleigh

    Motor-vehicles can be a predominant source of air pollution in cities. Traffic-related air pollution is often unavoidable for people who live in populous areas. Commuters may have high exposures to traffic-related air pollution as they are close to vehicle tailpipes. Volatile organic compounds (VOCs) are one class of air pollutants of concern because exposure to VOCs carries risk for adverse health effects. Specific VOCs of interest for this work include benzene, toluene, ethylbenzene, and xylenes (BTEX), which are often found in gasoline and combustion products. Although methods exist to measure time-integrated personal exposures to BTEX, there are few practical methods to measure a commuter's time-resolved BTEX exposure which could identify peak exposures that could be concealed with a time-integrated measurement. This study evaluated the ability of a photoionization detector (PID) to measure commuters' exposure to BTEX using Tenax TA samples as a reference and quantified the difference in BTEX exposure between cyclists and drivers with windows open and closed. To determine the suitability of two measurement methods (PID and Tenax TA) for use in this study, the precision, linearity, and limits of detection (LODs) for both the PID and Tenax TA measurement methods were determined in the laboratory with standard BTEX calibration gases. Volunteers commuted from their homes to their work places by cycling or driving while wearing a personal exposure backpack containing a collocated PID and Tenax TA sampler. Volunteers completed a survey and indicated if the windows in their vehicle were open or closed. Comparing pairs of exposure data from the Tenax TA and PID sampling methods determined the suitability of the PID to measure the BTEX exposures of commuters. The difference between BTEX exposures of cyclists and drivers with windows open and closed in Fort Collins was determined. Both the PID and Tenax TA measurement methods were precise and linear when evaluated in the laboratory using standard BTEX gases. The LODs for the Tenax TA sampling tubes (determined with a sample volume of 1,000 standard cubic centimeters which is close to the approximate commuter sample volumes collected) were orders of magnitude lower (0.04 to 0.7 parts per billion (ppb) for individual compounds of BTEX) compared to the PIDs' LODs (9.3 to 15 ppb of a BTEX mixture), which makes the Tenax TA sampling method more suitable to measure BTEX concentrations in the sub-parts per billion (ppb) range. PID and Tenax TA data for commuter exposures were inversely related. The concentrations of VOCs measured by the PID were substantially higher than BTEX concentrations measured by collocated Tenax TA samplers. The inverse trend and the large difference in magnitude between PID responses and Tenax TA BTEX measurements indicates the two methods may have been measuring different air pollutants that are negatively correlated. Drivers in Fort Collins, Colorado with closed windows experienced greater time-weighted average BTEX exposures than cyclists (p: 0.04). Commuter BTEX exposures measured in Fort Collins were lower than commuter exposures measured in prior studies that occurred in larger cities (Boston and Copenhagen). Although route and intake may affect a commuter's BTEX dose, these variables are outside of the scope of this study. Within the limitations of this study (including: small sample size, small representative area of Fort Collins, and respiration rates not taken into account), it appears health risks associated with traffic-induced BTEX exposures may be reduced by commuting via cycling instead of driving with windows closed and living in a less populous area that has less vehicle traffic. Although the PID did not reliably measure low-level commuter BTEX exposures, the Tenax TA sampling method did. The PID measured BTEX concentrations reliably in a controlled environment, at high concentrations (300-800 ppb), and in the absence of other air pollutants. In environments where there could be multiple chemicals present that may produce a PID signal (such as nitrogen dioxide), Tenax TA samplers may be a better choice for measuring BTEX. Tenax TA measurements were the only suitable method within this study to measure commuter's BTEX exposure in Fort Collins, Colorado.

  14. Pelvic Inflammatory Disease (PID)

    MedlinePlus

    ... a serious condition, in women. 1 in 8 women with a history of PID experience difficulties getting pregnant. You can prevent PID if you know how to protect yourself. What is PID? Pelvic inflammatory disease is an infection of a woman’s reproductive organs. It is a complication often caused ...

  15. The Personality Inventory for DSM-5 Short Form (PID-5-SF): psychometric properties and association with big five traits and pathological beliefs in a Norwegian population.

    PubMed

    Thimm, Jens C; Jordan, Stian; Bach, Bo

    2016-12-07

    With the publication of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), an alternative model for personality disorders based on personality dysfunction and pathological personality traits was introduced. The Personality Inventory for DSM-5 (PID-5) is a 220-item self-report inventory designed to assess the personality traits of this model. Recently, a short 100-item version of the PID-5 (PID-5-SF) has been developed. The aim of this study was to investigate the score reliability and structure of the Norwegian PID-5-SF. Further, criterion validity with the five factor model of personality (FFM) and pathological personality beliefs was examined. A derivation sample of university students (N = 503) completed the PID-5, the Big Five Inventory (BFI), and the Personality Beliefs Questionnaire - Short Form (PBQ-SF), whereas a replication sample of 127 students completed the PID-5-SF along with the aforementioned measures. The short PID-5 showed overall good score reliability and structural validity. The associations with FFM traits and pathological personality beliefs were conceptually coherent and similar for the two forms of the PID-5. The results suggest that the Norwegian PID-5 short form is a reliable and efficient measure of the trait criterion of the alternative model for personality disorders in DSM-5.

  16. Impact of PID on industrial rooftop PV-installations

    NASA Astrophysics Data System (ADS)

    Buerhop, Claudia; Fecher, Frank W.; Pickel, Tobias; Patel, Tirth; Zetzmann, Cornelia; Camus, Christian; Hauch, Jens; Brabec, Christoph J.

    2017-08-01

    Potential induced degradation (PID) causes severe damage and financial losses even in modern PV-installations. In Germany, approximately 19% of PV-installations suffer from PID and resulting power loss. This paper focuses on the impact of PID in real installations and how different evaluated time intervals influence the performance ratio (PR) and the determined degradation rate. The analysis focuses exemplarily on a 314 kWp PV-system in the Atlantic coastal climate. IR-imaging is used for identifying PID without operation interruption. Historic electric performance data are available from a monitoring system for several years on system level, string level as well as punctually measured module string IV- curves. The data sets are combined for understanding the PID behavior of this PV plant. The number of PID affected cells within a string varies strongly between 1 to 22% with the string position on the building complex. With increasing number of PID-affected cells the performance ratio decreases down to 60% for daily and monthly periods. Local differences in PID evolution rates are identified. An average PR-reduction of -3.65% per year is found for the PV-plant. On the string level the degradation rate varied up to 8.8% per year depending on the string position and the time period. The analysis reveals that PID generation and evolution in roof-top installations on industrial buildings with locally varying operation conditions can be fairly complex. The results yield that local operating conditions, e.g. ambient weather conditions as well as surrounding conditions on an industrial building, seem to have a dominating impact on the PID evolution rate.

  17. Tuning algorithms for fractional order internal model controllers for time delay processes

    NASA Astrophysics Data System (ADS)

    Muresan, Cristina I.; Dutta, Abhishek; Dulf, Eva H.; Pinar, Zehra; Maxim, Anca; Ionescu, Clara M.

    2016-03-01

    This paper presents two tuning algorithms for fractional-order internal model control (IMC) controllers for time delay processes. The two tuning algorithms are based on two specific closed-loop control configurations: the IMC control structure and the Smith predictor structure. In the latter, the equivalency between IMC and Smith predictor control structures is used to tune a fractional-order IMC controller as the primary controller of the Smith predictor structure. Fractional-order IMC controllers are designed in both cases in order to enhance the closed-loop performance and robustness of classical integer order IMC controllers. The tuning procedures are exemplified for both single-input-single-output as well as multivariable processes, described by first-order and second-order transfer functions with time delays. Different numerical examples are provided, including a general multivariable time delay process. Integer order IMC controllers are designed in each case, as well as fractional-order IMC controllers. The simulation results show that the proposed fractional-order IMC controller ensures an increased robustness to modelling uncertainties. Experimental results are also provided, for the design of a multivariable fractional-order IMC controller in a Smith predictor structure for a quadruple-tank system.

  18. Hastatic order in URu2Si2 : Hybridization with a twist

    NASA Astrophysics Data System (ADS)

    Chandra, Premala; Coleman, Piers; Flint, Rebecca

    2015-05-01

    The broken symmetry that develops below 17.5 K in the heavy fermion compound URu2Si2 has long eluded identification. Here we argue that the recent observation of Ising quasiparticles in URu2Si2 results from a spinor hybridization order parameter that breaks double time-reversal symmetry by mixing states of integer and half-integer spin. Such "hastatic order" (hasta: [Latin] spear) hybridizes Kramers conduction electrons with Ising, non-Kramers 5 f2 states of the uranium atoms to produce Ising quasiparticles. The development of a spinorial hybridization at 17.5 K accounts for both the large entropy of condensation and the magnetic anomaly observed in torque magnetometry. This paper develops the theory of hastatic order in detail, providing the mathematical development of its key concepts. Hastatic order predicts a tiny transverse moment in the conduction sea, a colossal Ising anisotropy in the nonlinear susceptibility anomaly and a resonant energy-dependent nematicity in the tunneling density of states.

  19. Disturbance rejection performance analyses of closed loop control systems by reference to disturbance ratio.

    PubMed

    Alagoz, Baris Baykant; Deniz, Furkan Nur; Keles, Cemal; Tan, Nusret

    2015-03-01

    This study investigates disturbance rejection capacity of closed loop control systems by means of reference to disturbance ratio (RDR). The RDR analysis calculates the ratio of reference signal energy to disturbance signal energy at the system output and provides a quantitative evaluation of disturbance rejection performance of control systems on the bases of communication channel limitations. Essentially, RDR provides a straightforward analytical method for the comparison and improvement of implicit disturbance rejection capacity of closed loop control systems. Theoretical analyses demonstrate us that RDR of the negative feedback closed loop control systems are determined by energy spectral density of controller transfer function. In this manner, authors derived design criteria for specifications of disturbance rejection performances of PID and fractional order PID (FOPID) controller structures. RDR spectra are calculated for investigation of frequency dependence of disturbance rejection capacity and spectral RDR analyses are carried out for PID and FOPID controllers. For the validation of theoretical results, simulation examples are presented. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Coordinating IMC-PID and adaptive SMC controllers for a PEMFC.

    PubMed

    Wang, Guo-Liang; Wang, Yong; Shi, Jun-Hai; Shao, Hui-He

    2010-01-01

    For a Proton Exchange Membrane Fuel Cell (PEMFC) power plant with a methanol reformer, the process parameters and power output are considered simultaneously to avoid violation of the constraints and to keep the fuel cell power plant safe and effective. In this paper, a novel coordinating scheme is proposed by combining an Internal Model Control (IMC) based PID Control and adaptive Sliding Mode Control (SMC). The IMC-PID controller is designed for the reformer of the fuel flow rate according to the expected first-order dynamic properties. The adaptive SMC controller of the fuel cell current has been designed using the constant plus proportional rate reaching law. The parameters of the SMC controller are adaptively tuned according to the response of the fuel flow rate control system. When the power output controller feeds back the current references to these two controllers, the coordinating controllers system works in a system-wide way. The simulation results of the PEMFC power plant demonstrate the effectiveness of the proposed method. 2009 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Model predictive control of the solid oxide fuel cell stack temperature with models based on experimental data

    NASA Astrophysics Data System (ADS)

    Pohjoranta, Antti; Halinen, Matias; Pennanen, Jari; Kiviaho, Jari

    2015-03-01

    Generalized predictive control (GPC) is applied to control the maximum temperature in a solid oxide fuel cell (SOFC) stack and the temperature difference over the stack. GPC is a model predictive control method and the models utilized in this work are ARX-type (autoregressive with extra input), multiple input-multiple output, polynomial models that were identified from experimental data obtained from experiments with a complete SOFC system. The proposed control is evaluated by simulation with various input-output combinations, with and without constraints. A comparison with conventional proportional-integral-derivative (PID) control is also made. It is shown that if only the stack maximum temperature is controlled, a standard PID controller can be used to obtain output performance comparable to that obtained with the significantly more complex model predictive controller. However, in order to control the temperature difference over the stack, both the stack minimum and the maximum temperature need to be controlled and this cannot be done with a single PID controller. In such a case the model predictive controller provides a feasible and effective solution.

  2. Optimal fractional order PID design via Tabu Search based algorithm.

    PubMed

    Ateş, Abdullah; Yeroglu, Celaleddin

    2016-01-01

    This paper presents an optimization method based on the Tabu Search Algorithm (TSA) to design a Fractional-Order Proportional-Integral-Derivative (FOPID) controller. All parameter computations of the FOPID employ random initial conditions, using the proposed optimization method. Illustrative examples demonstrate the performance of the proposed FOPID controller design method. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Pelvic inflammatory disease and sepsis.

    PubMed

    Dulin, Judy D; Akers, Mary C

    2003-03-01

    Pelvic inflammatory disease affects approximately 1 million women per year in the United States alone and has a variety of causative organisms. Because the diagnosis of PID is based on clinical judgment, health care providers need to be guided by the CDC recommendations for diagnosing and treating PID. Because presenting symptoms are often vague, the health care provider should assess female patients for risky behaviors that may lead to PID and should use screening data when making clinical judgments and differential diagnoses. Whenever possible, female patients with PID should be treated as outpatients. If diagnosis and treatment are not performed in a timely manner, PID may cause sepsis, septic shock, and even death. Even if they survive, as many as 15% to 20% of these women experience long-term sequelae of PID, such as ectopic pregnancy, tubo-ovarian abscess, infertility, dyspareunia, and chronic pelvic pain. The best treatments for PID are interventions that lead to prevention and early detection. The critical care nurse has an important role in recognizing the variables that may lead to PID-related sepsis and in encouraging health-seeking and health-maintenance behaviors among women with these diagnoses.

  4. IUD users may have higher risk of contracting PID, studies find; pill may have protective effect.

    PubMed

    1980-01-01

    The incidence of pelvic inflammatory disease (PID), which can lead to serious reproductive impairment, infertility, or ectopic pregnancy, is increasing worldwide. About 500,000 women in their childbearing years contract PID for the first time each year in the U.S., and the incidence among young women appears to be increasing. Sexually transmitted diseases are responsible for many PID cases worldwide, while in developing countries postpartum and postabortion sepsis and endemic diseases such as filariasis and schistosomiasis may also be implicated. Some increase of PID is associated with legal abortion and IUD insertion, while pill use appears to protect women from PID. A worldwide review of medical literature indicates that the risk of PID is 3.5 times greater for IUD users than for nonusers, although several variables other than IUD use affect PID risk, such as age, race, socioeconomic status, and sexual activity. The risk for never pregnant IUD users in a Swedish study was 11.8 per 100 woman years, compared to 3.4 for ever-pregnant IUD users. There was no difference in relative risk for users of the pill or barrier methods, or for non-contraceptors. Another study reported a higher relative risk of PID related to duration of IUD use.

  5. Risk of psychiatric disorders following pelvic inflammatory disease: a nationwide population-based retrospective cohort study.

    PubMed

    Shen, Cheng-Che; Yang, Albert C; Hung, Jeng-Hsiu; Hu, Li-Yu; Chiang, Yung-Yen; Tsai, Shih-Jen

    2016-01-01

    Pelvic inflammatory disease (PID) a common infection in women that is associated with significant morbidity and is a major cause of infertility. A clear temporal causal relationship between PID and psychiatric disorders has not been well established. We used a nationwide population-based retrospective cohort study to explore the relationship between PID and the subsequent development of psychiatric disorders. We identified subjects who were newly diagnosed with PID between 1 January 2000 and 31 December 2002 in the Taiwan National Health Insurance Research Database. A comparison cohort was constructed for patients without PID. A total of 21 930 PID and 21 930 matched control patients were observed until diagnosed with psychiatric disorders, or until death, withdrawal from the NHI system, or until 31 December 2009. Adjusted hazard ratio (HR) of bipolar disorder, depressive disorder, anxiety disorder and sleep disorder in subjects with PID were significantly higher (HR: 2.671, 2.173, 2.006 and 2.251, respectively) than that of the controls during the follow-up. PID may increase the risk of subsequent newly diagnosed bipolar disorder, depressive disorder, anxiety disorder and sleep disorder, which will impair life quality. Our findings highlight that clinicians should pay particular attention to psychiatric comorbidities in PID patients.

  6. Utility of the Personality Inventory for DSM-5-Brief Form (PID-5-BF) in the Measurement of Maladaptive Personality and Psychopathology.

    PubMed

    Anderson, Jaime L; Sellbom, Martin; Salekin, Randall T

    2018-07-01

    The Diagnostic and Statistical Manual of Mental Disorders-Fifth edition ( DSM-5) Personality and Personality Disorders workgroup developed the Personality Inventory for the DSM-5 (PID-5) for the assessment of the alternative trait model for DSM-5. Along with this measure, the American Psychiatric Association published an abbreviated version, the PID-5-Brief form (PID-5-BF). Although this measure is available on the DSM-5 website for use, only two studies have evaluated its psychometric properties and validity and no studies have examined the U.S. version of this measure. The current study evaluated the reliability, factor structure, and construct validity of PID-5-BF scale scores. This included an evaluation of the scales' associations with Section II PDs, a well-validated dimensional measure of personality psychopathology, and broad externalizing and internalizing psychopathology measures. We found support for the reliability of PID-5-BF scales as well as for the factor structure of the measure. Furthermore, a series of correlation and regression analyses showed conceptually expected associations between PID-5-BF and external criterion variables. Finally, we compared the correlations with external criterion measures to those of the full-length PID-5 and PID-5-Short form. Intraclass correlation analyses revealed a comparable pattern of correlations across all three measures, thereby supporting the use of the PID-5-BF as a screening measure of dimensional maladaptive personality traits.

  7. Fuzzy PID control algorithm based on PSO and application in BLDC motor

    NASA Astrophysics Data System (ADS)

    Lin, Sen; Wang, Guanglong

    2017-06-01

    A fuzzy PID control algorithm is studied based on improved particle swarm optimization (PSO) to perform Brushless DC (BLDC) motor control which has high accuracy, good anti-jamming capability and steady state accuracy compared with traditional PID control. The mathematical and simulation model is established for BLDC motor by simulink software, and the speed loop of the fuzzy PID controller is designed. The simulation results show that the fuzzy PID control algorithm based on PSO has higher stability, high control precision and faster dynamic response speed.

  8. The application of neural network PID controller to control the light gasoline etherification

    NASA Astrophysics Data System (ADS)

    Cheng, Huanxin; Zhang, Yimin; Kong, Lingling; Meng, Xiangyong

    2017-06-01

    Light gasoline etherification technology can effectively improve the quality of gasoline, which is environmental- friendly and economical. By combining BP neural network and PID control and using BP neural network self-learning ability for online parameter tuning, this method optimizes the parameters of PID controller and applies this to the Fcc gas flow control to achieve the control of the final product- heavy oil concentration. Finally, through MATLAB simulation, it is found that the PID control based on BP neural network has better controlling effect than traditional PID control.

  9. Design and implementation of a 2-DOF PID compensation for magnetic levitation systems.

    PubMed

    Ghosh, Arun; Rakesh Krishnan, T; Tejaswy, Pailla; Mandal, Abhisek; Pradhan, Jatin K; Ranasingh, Subhakant

    2014-07-01

    This paper employs a 2-DOF (degree of freedom) PID controller for compensating a physical magnetic levitation system. It is shown that because of having a feedforward gain in the proposed 2-DOF PID control, the transient performance of the compensated system can be changed in a desired manner unlike the conventional 1-DOF PID control. It is also shown that for a choice of PID parameters, although the theoretical loop robustness is the same for both the compensated systems, in real-time, 2-DOF PID control may provide superior robustness if a suitable choice of the feedforward parameter is made. The results are verified through simulations and experiments. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Some operational tools for solving fractional and higher integer order differential equations: A survey on their mutual relations

    NASA Astrophysics Data System (ADS)

    Kiryakova, Virginia S.

    2012-11-01

    The Laplace Transform (LT) serves as a basis of the Operational Calculus (OC), widely explored by engineers and applied scientists in solving mathematical models for their practical needs. This transform is closely related to the exponential and trigonometric functions (exp, cos, sin) and to the classical differentiation and integration operators, reducing them to simple algebraic operations. Thus, the classical LT and the OC give useful tool to handle differential equations and systems with constant coefficients. Several generalizations of the LT have been introduced to allow solving, in a similar way, of differential equations with variable coefficients and of higher integer orders, as well as of fractional (arbitrary non-integer) orders. Note that fractional order mathematical models are recently widely used to describe better various systems and phenomena of the real world. This paper surveys briefly some of our results on classes of such integral transforms, that can be obtained from the LT by means of "transmutations" which are operators of the generalized fractional calculus (GFC). On the list of these Laplace-type integral transforms, we consider the Borel-Dzrbashjan, Meijer, Krätzel, Obrechkoff, generalized Obrechkoff (multi-index Borel-Dzrbashjan) transforms, etc. All of them are G- and H-integral transforms of convolutional type, having as kernels Meijer's G- or Fox's H-functions. Besides, some special functions (also being G- and H-functions), among them - the generalized Bessel-type and Mittag-Leffler (M-L) type functions, are generating Gel'fond-Leontiev (G-L) operators of generalized differentiation and integration, which happen to be also operators of GFC. Our integral transforms have operational properties analogous to those of the LT - they do algebrize the G-L generalized integrations and differentiations, and thus can serve for solving wide classes of differential equations with variable coefficients of arbitrary, including non-integer order. Throughout the survey, we illustrate the parallels in the relationships: Laplace type integral transforms - special functions as kernels - operators of generalized integration and differentiation generated by special functions - special functions as solutions of related differential equations. The role of the so-called Special Functions of Fractional Calculus is emphasized.

  11. Design and Simulation of a PID Controller for Motion Control Systems

    NASA Astrophysics Data System (ADS)

    Hassan Abdullahi, Zakariyya; Danzomo, Bashir Ahmed; Suleiman Abdullahi, Zainab

    2018-04-01

    Motion control system plays important role in many industrial applications among which are in robot system, missile launching, positioning systems etc. However, the performance requirement for these applications in terms of high accuracy, high speed, insignificant or no overshoot and robustness have generated continuous challenges in the field of motion control system design and implementation. To compensate this challenge, a PID controller was design using mathematical model of a DC motor based on classical root-locus approach. The reason for adopting root locus design is to remodel the closed-loop response by putting the closed-loop poles of the system at desired points. Adding poles and zeros to the initial open-loop transfer function through the controller provide a way to transform the root locus in order to place the closed-loop poles at the required points. This process can also be used for discrete-time models. The Advantages of root locus over other methods is that, it gives the better way of pinpointing the parameters and can easily predict the fulfilment of the whole system. The controller performance was simulated using MATLAB code and a reasonable degree of accuracy was obtained. Implementation of the proposed model was conducted using-Simulink and the result obtained shows that the PID controller met the transient performance specifications with both settling time and overshoot less than 0.1s and 5% respectively. In terms of steady state error, the PID controller gave good response for both step input and ramp.

  12. Moderately virulent African swine fever virus infection: blood cell changes and infective virus distribution among blood components.

    PubMed

    Genovesi, E V; Knudsen, R C; Whyard, T C; Mebus, C A

    1988-03-01

    Blood samples of pigs infected with a moderately virulent African swine fever virus (ASFV) isolate, obtained from the Dominican Republic (DR-II), were monitored temporally for viremia, infective ASFV association with major blood components, differential changes in blood cell composition, and plasma antibodies to ASFV. After intranasal/oral virus inoculation, pigs underwent acute infection and illness that resolved. Acute illness began on postinoculation day (PID) 4 and continued to PID 11, and pigs were febrile, with maximal infective ASFV titers detected in blood. By PID 11, initial antibody titers to ASFV antigens were detected in plasma. The WBC numbers were maintained near preinoculation counts; however, lymphocyte counts decreased slightly with a compensatory increment in neutrophil and monocyte numbers. From PID 11 to PID 25, rectal temperatures gradually returned to preinoculation values, titers of viremia began to decrease, plasma antibody to ASFV antigens increased to peak titers, and WBC numbers increased slightly. Percentages of lymphocytes returned to preinoculation values, neutrophil percentages decreased to slightly below preinoculation values, monocyte percentages were mildly increased, and eosinophil percentages were unaffected. From PID 25 to PID 46, titers of viremia further decreased, and plasma titers of antibodies to ASFV antigens remained high. In pigs with DR-II viremia (PID 4 to PID 46), most viral infectivity (greater than 95%) was RBC associated. Plasma contained less than 1% infectivity, and less than 0.1% of virus was in the WBC fraction (monocytes, lymphocytes, and granulocytes). After PID 46, viremia was no longer detectable.

  13. Pinoid kinase regulates root gravitropism through modulation of PIN2-dependent basipetal auxin transport in Arabidopsis thaliana

    NASA Astrophysics Data System (ADS)

    Muday, Gloria; Sukumar, Poornima; Edwards, Karin; Delong, Alison; Rahman, Abidur

    Reversible protein phosphorylation is a key regulatory mechanism governing polar auxin transport. We tested the hypothesis that PINOID (PID)-mediated phosphorylation and RCN1- regulated dephosphorylation might antagonistically regulate auxin transport and gravity response in seedling roots. Here we show that basipetal IAA transport and gravitropism are reduced in pid mutant seedlings, while acropetal transport and lateral root development are unchanged. Treatment of wild-type seedlings with the protein kinase inhibitor, staurosporine, phenocopied the reduced auxin transport and gravity response of pid-9 and reduced formation of asymmetric DR5-revGFP expression at the root tip after reorientation relative to gravity. Gravitropism and auxin transport in pid are resistant to further inhibition by staurosporine. Gravity response defects of rcn1 and pid-9 are partially rescued by treatment with staurosporine or the phosphatase inhibitor, cantharidin, respectively, and in the pid-9 rcn1 double mutant. Furthermore, the effect of staurosporine is lost in pin2, and a PIN2::GFP fusion protein accumulates in endomembrane compartments after staurosporine treatment. In the pid-9 mutant, immunological techniques find a similar PIN2 localization. These data suggest that staurosporine inhibits gravitropism and basipetal IAA transport by blocking PID action and altering PIN2 localization and support the model that PID and RCN1 reciprocally regulate root gravitropic curvature.

  14. The Personality Inventory for DSM-5 Brief Form: Evidence for Reliability and Construct Validity in a Sample of Community-Dwelling Italian Adolescents.

    PubMed

    Fossati, Andrea; Somma, Antonella; Borroni, Serena; Markon, Kristian E; Krueger, Robert F

    2017-07-01

    To assess the reliability and construct validity of the Personality Inventory for DSM-5 Brief Form (PID-5-BF) among adolescents, 877 Italian high school students were administered the PID-5-BF. Participants were administered also the Measure of Disordered Personality Functioning (MDPF) as a criterion measure. In the full sample, Cronbach's alpha values for the PID-5-BF scales ranged from .59 (Detachment) to .77 (Psychoticism); in addition, all PID-5-BF scales showed mean interitem correlation values in the .22 to .40 range. Cronbach's alpha values for the PID-5-BF total score was .83 (mean interitem r = .16). Although 2-month test-retest reliability could be assessed only in a small ( n = 42) subsample of participants, all PID-5-BF scale scores showed adequate temporal stability, as indexed by intraclass r values ranging from .78 (Negative Affectivity) to .97 (Detachment), all ps <.001. Exploratory structural equation modeling analyses provided at least moderate support for the a priori model of PID-5-BF items. Multiple regression analyses showed that PID-5-BF scales predicted a nonnegligible amount of variance in MDPF Non-Cooperativeness, adjusted R 2 = .17, p < .001, and Non-Coping scales, adjusted R 2 = .32, p < .001. Similarly, the PID-5-BF total score was a significant predictor of both MDPF Non-Coping, and Non-Cooperativeness scales.

  15. Handling Qualities Specifications for U.S. Military Helicopters

    NASA Technical Reports Server (NTRS)

    Key, David L.

    1982-01-01

    Inadequacies in the military specification for helicopter handling qualities, MIL-H-8501A, have long been recognized, and the latest procurements by the U.S. Army used special Prime Item Development Specifications (PIDS). This paper assesses the efficacy of these PIDS and suggests that changes should be made. In particular, the structure developed in MIL-F-8785B (ASG) (the specification for flying qualities of piloted airplanes) should be incorporated. Improved requirements must be based on a systematic data base and concentrated on topics most important in preliminary design: static and dynamic stability, control power and sensitivity, and interaction with controllers and displays. Emphasis should be on current military helicopter missions and helicopter idiosyncrasies such as cross-coupling, nonlinearities, and higher-order dynamics.

  16. On the populating mechanisms of the autoionising states of Al III ions produced in a Penning ionisation discharge

    NASA Technical Reports Server (NTRS)

    Finkenthal, M.; Littman, A.; Stutman, D.; Bhatia, A. K.

    1989-01-01

    Spectra emitted by Al II and Al III in the 100-1900-A range from a Penning ionization discharge (PID) have been analyzed in order to study the populating mechanisms of the autoionizing levels of the Al III ion. Electron temperature and density estimates and Al III line intensities obtained using a collisional-radiative model are found to differ from those obtained experimentally, implying that the autoionizing levels of the Na I-like ion may be populated, in the PID plasma, by the inner-shell ionization of excited Mg I-like ions. It is suggested that such autoionizing lines could be used to search for populations inversions in the soft X-ray domain.

  17. Design and experimental validation of linear and nonlinear vehicle steering control strategies

    NASA Astrophysics Data System (ADS)

    Menhour, Lghani; Lechner, Daniel; Charara, Ali

    2012-06-01

    This paper proposes the design of three control laws dedicated to vehicle steering control, two based on robust linear control strategies and one based on nonlinear control strategies, and presents a comparison between them. The two robust linear control laws (indirect and direct methods) are built around M linear bicycle models, each of these control laws is composed of two M proportional integral derivative (PID) controllers: one M PID controller to control the lateral deviation and the other M PID controller to control the vehicle yaw angle. The indirect control law method is designed using an oscillation method and a nonlinear optimisation subject to H ∞ constraint. The direct control law method is designed using a linear matrix inequality optimisation in order to achieve H ∞ performances. The nonlinear control method used for the correction of the lateral deviation is based on a continuous first-order sliding-mode controller. The different methods are designed using a linear bicycle vehicle model with variant parameters, but the aim is to simulate the nonlinear vehicle behaviour under high dynamic demands with a four-wheel vehicle model. These steering vehicle controls are validated experimentally using the data acquired using a laboratory vehicle, Peugeot 307, developed by National Institute for Transport and Safety Research - Department of Accident Mechanism Analysis Laboratory's (INRETS-MA) and their performance results are compared. Moreover, an unknown input sliding-mode observer is introduced to estimate the road bank angle.

  18. Synchronizable Series Expressions. Part 2. Overview of the Theory and Implementation.

    DTIC Science & Technology

    1987-11-01

    more running time than shown in the table. because time is eventually required in order to collect the garbage it creates. Program Running ’rime Garbage...possible to simply put an enumerator where it is used.) (loop for x integer from I to 4 collect x) - (lotS* ((x (Eup I :to 4))) (declare (type integer x...below. (loop for x from 1 to 4 and for y = 0 then (1- x) collect (list x y)) - (lotS* ((x (Eup 1 :to 4)) (y (Tprevious (1- x) 0))) (Rlist (list x y

  19. Treatment of Acute Pelvic Inflammatory Disease

    PubMed Central

    Sweet, Richard L.

    2011-01-01

    Pelvic inflammatory disease (PID), one of the most common infections in nonpregnant women of reproductive age, remains an important public health problem. It is associated with major long-term sequelae, including tubal factor infertility, ectopic pregnancy, and chronic pelvic pain. In addition, treatment of acute PID and its complications incurs substantial health care costs. Prevention of these long-term sequelae is dependent upon development of treatment strategies based on knowledge of the microbiologic etiology of acute PID. It is well accepted that acute PID is a polymicrobic infection. The sexually transmitted organisms, Neisseria gonorrhoeae and Chlamydia trachomatis, are present in many cases, and microorganisms comprising the endogenous vaginal and cervical flora are frequently associated with PID. This includes anaerobic and facultative bacteria, similar to those associated with bacterial vaginosis. Genital tract mycoplasmas, most importantly Mycoplasma genitalium, have recently also been implicated as a cause of acute PID. As a consequence, treatment regimens for acute PID should provide broad spectrum coverage that is effective against these microorganisms. PMID:22228985

  20. Supply-demand mismatch transients in susceptible peri-infarct hot zones explain the origins of spreading injury depolarizations.

    PubMed

    von Bornstädt, Daniel; Houben, Thijs; Seidel, Jessica L; Zheng, Yi; Dilekoz, Ergin; Qin, Tao; Sandow, Nora; Kura, Sreekanth; Eikermann-Haerter, Katharina; Endres, Matthias; Boas, David A; Moskowitz, Michael A; Lo, Eng H; Dreier, Jens P; Woitzik, Johannes; Sakadžić, Sava; Ayata, Cenk

    2015-03-04

    Peri-infarct depolarizations (PIDs) are seemingly spontaneous spreading depression-like waves that negatively impact tissue outcome in both experimental and human stroke. Factors triggering PIDs are unknown. Here, we show that somatosensory activation of peri-infarct cortex triggers PIDs when the activated cortex is within a critical range of ischemia. We show that the mechanism involves increased oxygen utilization within the activated cortex, worsening the supply-demand mismatch. We support the concept by clinical data showing that mismatch predisposes stroke patients to PIDs as well. Conversely, transient worsening of mismatch by episodic hypoxemia or hypotension also reproducibly triggers PIDs. Therefore, PIDs are triggered upon supply-demand mismatch transients in metastable peri-infarct hot zones due to increased demand or reduced supply. Based on the data, we propose that minimizing sensory stimulation and hypoxic or hypotensive transients in stroke and brain injury would reduce PID incidence and their adverse impact on outcome. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Longitudinal control of aircraft dynamics based on optimization of PID parameters

    NASA Astrophysics Data System (ADS)

    Deepa, S. N.; Sudha, G.

    2016-03-01

    Recent years many flight control systems and industries are employing PID controllers to improve the dynamic behavior of the characteristics. In this paper, PID controller is developed to improve the stability and performance of general aviation aircraft system. Designing the optimum PID controller parameters for a pitch control aircraft is important in expanding the flight safety envelope. Mathematical model is developed to describe the longitudinal pitch control of an aircraft. The PID controller is designed based on the dynamic modeling of an aircraft system. Different tuning methods namely Zeigler-Nichols method (ZN), Modified Zeigler-Nichols method, Tyreus-Luyben tuning, Astrom-Hagglund tuning methods are employed. The time domain specifications of different tuning methods are compared to obtain the optimum parameters value. The results prove that PID controller tuned by Zeigler-Nichols for aircraft pitch control dynamics is better in stability and performance in all conditions. Future research work of obtaining optimum PID controller parameters using artificial intelligence techniques should be carried out.

  2. Supply-demand mismatch transients in susceptible peri-infarct hot zones explain the origin of spreading injury depolarizations

    PubMed Central

    von Bornstädt, Daniel; Houben, Thijs; Seidel, Jessica; Zheng, Yi; Dilekoz, Ergin; Qin, Tao; Sandow, Nora; Kura, Sreekanth; Eikermann-Haerter, Katharina; Endres, Matthias; Boas, David A.; Moskowitz, Michael A.; Lo, Eng H.; Dreier, Jens P.; Woitzik, Johannes; Sakadžić, Sava; Ayata, Cenk

    2015-01-01

    SUMMARY Peri-infarct depolarizations (PIDs) are seemingly spontaneous spreading depression-like waves that negatively impact tissue outcome in both experimental and human stroke. Factors triggering PIDs are unknown. Here, we show that somatosensory activation of peri-infarct cortex triggers PIDs when the activated cortex is within a critical range of ischemia. We show that the mechanism involves increased oxygen utilization within the activated cortex, worsening the supply-demand mismatch. We support the concept by clinical data showing that mismatch predisposes to PIDs in human stroke as well. Conversely, transient worsening of mismatch by episodic hypoxemia or hypotension also reproducibly triggers PIDs. Therefore, PIDs are triggered upon supply-demand mismatch transients in metastable peri-infarct hot zones due to increased demand or reduced supply. Based on the data, we propose that minimizing sensory stimulation and hypoxic or hypotensive transients in stroke and brain injury would reduce PID incidence and their adverse impact on outcome. PMID:25741731

  3. Optimizing Multi-Product Multi-Constraint Inventory Control Systems with Stochastic Replenishments

    NASA Astrophysics Data System (ADS)

    Allah Taleizadeh, Ata; Aryanezhad, Mir-Bahador; Niaki, Seyed Taghi Akhavan

    Multi-periodic inventory control problems are mainly studied employing two assumptions. The first is the continuous review, where depending on the inventory level orders can happen at any time and the other is the periodic review, where orders can only happen at the beginning of each period. In this study, we relax these assumptions and assume that the periodic replenishments are stochastic in nature. Furthermore, we assume that the periods between two replenishments are independent and identically random variables. For the problem at hand, the decision variables are of integer-type and there are two kinds of space and service level constraints for each product. We develop a model of the problem in which a combination of back-order and lost-sales are considered for the shortages. Then, we show that the model is of an integer-nonlinear-programming type and in order to solve it, a search algorithm can be utilized. We employ a simulated annealing approach and provide a numerical example to demonstrate the applicability of the proposed methodology.

  4. [Acute renal insufficiency caused by phenyl-indane-dione. Apropos of 1 case].

    PubMed

    Horellou, M F; Feiss, P; Voultoury, J C; Gay, R

    1978-01-01

    One case of Phenindione (PID) adverse reaction is reported. The patient showed a typical picture of immunological reaction to the drug. In spite of severe bacteremia, she recovered. Only 33 cases of PID intolerance are reported in the literature. In all these patients, renal failure occurred. Superinfection is the most frequent cause of death. PID adverse reaction should be evoqued in the presence of signs such a fever, asthenia, anorexia and cutaneous reaction. The PID should be stopped immediatly but renal failure yet develops. During a PID treatment, frequent evaluation of blood azotemia, creatinine and proteinuria should be performed.

  5. [Blood anticoagulation system and urine fibrinolysis in newborn infants with suppurative-inflammatory diseases].

    PubMed

    Samsygina, G A; Vykhristiuk, O F

    1989-01-01

    The anticoagulative blood system, blood and urine fibrinolysis were studied in 95 children with pyo-inflammatory diseases (PID) and in 56 normal neonates aged 2 to 28 days. The patients afflicted with PID were distributed into 3 groups; group I included patients with uneventful localized PID, group II consisted of patients with grave PID, and group III of patients with sepsis. Hemostasis and urine fibrinolysis were compared according to 20 indicators. The intensity and involvement of certain components of the fibrinolytic and anticoagulative blood systems in PID turned out different and were dependent on the disease gravity.

  6. Comparison of the population excess fraction of Chlamydia trachomatis infection on pelvic inflammatory disease at 12-months in the presence and absence of chlamydia testing and treatment: Systematic review and retrospective cohort analysis

    PubMed Central

    Turner, Katy M. E.; Leung, Stella; Yu, B. Nancy; Frølund, Maria; Benfield, Thomas; Blanchard, James; Westh, Henrik; Ward, Helen

    2017-01-01

    Background The impact of Chlamydia trachomatis (chlamydia) control on the incidence of pelvic inflammatory disease (PID) is theoretically limited by the proportion of PID caused by chlamydia. We estimate the population excess fraction (PEF) of treated chlamydia infection on PID at 12-months in settings with widespread chlamydia control (testing and treatment) and compare this to the estimated PEF of untreated chlamydia. Methods We used two large retrospective population-based cohorts of women of reproductive age from settings with widespread chlamydia control to calculate the PEF of treated chlamydia on PID at 12-months. We undertook a systematic review to identify further studies that reported the risk of PID in women who were tested for chlamydia (infected and uninfected). We used the same method to calculate the PEF in eligible studies then compared all estimates of PEF. Results The systematic review identified a single study, a randomised controlled trial of chlamydia screening (POPI-RCT). In the presence of testing and treatment <10% of PID at 12-months was attributable to treated (baseline) chlamydia infections (Manitoba: 8.86%(95%CI 7.15–10.75); Denmark: 3.84%(3.26–4.45); screened-arm POPI-RCT: 0.99%(0.00–29.06)). In the absence of active chlamydia treatment 26.44%(11.57–46.32) of PID at 12-months was attributable to untreated (baseline) chlamydia infections (deferred-arm POPI-RCT). The PEFs suggest that eradicating baseline chlamydia infections could prevent 484 cases of PID at 12-months per 100,000 women in the untreated setting and 13–184 cases of PID per 100,000 tested women in the presence of testing and treatment. Conclusion Testing and treating chlamydia reduced the PEF of chlamydia on PID by 65% compared to the untreated setting. But in the presence of testing and treatment over 90% of PID could not be attributed to a baseline chlamydia infection. More information is needed about the aetiology of PID to develop effective strategies for improving the reproductive health of women. PMID:28199392

  7. Pelvic Inflammatory Disease (PID)

    MedlinePlus

    ... Education FAQs Pelvic Inflammatory Disease (PID) Patient Education Pamphlets - Spanish Pelvic Inflammatory Disease (PID) FAQ077, September 2015 ... on Patient Safety For Patients Patient FAQs Spanish Pamphlets Teen Health About ACOG About Us Leadership & Governance ...

  8. Hospitalisations for pelvic inflammatory disease temporally related to a diagnosis of Chlamydia or gonorrhoea: a retrospective cohort study.

    PubMed

    Reekie, Joanne; Donovan, Basil; Guy, Rebecca; Hocking, Jane S; Jorm, Louisa; Kaldor, John M; Mak, Donna B; Preen, David; Pearson, Sallie; Roberts, Christine L; Stewart, Louise; Wand, Handan; Ward, James; Liu, Bette

    2014-01-01

    The presence and severity of pelvic inflammatory disease (PID) symptoms are thought to vary by microbiological etiology but there is limited empirical evidence. We sought to estimate and compare the rates of hospitalisation for PID temporally related to diagnoses of gonorrhoea and chlamydia. All women, aged 15-45 years in the Australian state of New South Wales (NSW), with a diagnosis of chlamydia or gonorrhoea between 01/07/2000 and 31/12/2008 were followed by record linkage for up to one year after their chlamydia or gonorrhoea diagnosis for hospitalisations for PID. Standardised incidence ratios compared the incidence of PID hospitalisations to the age-equivalent NSW population. A total of 38,193 women had a chlamydia diagnosis, of which 483 were hospitalised for PID; incidence rate (IR) 13.9 per 1000 person-years of follow-up (PYFU) (95%CI 12.6-15.1). In contrast, 1015 had a gonorrhoea diagnosis, of which 45 were hospitalised for PID (IR 50.8 per 1000 PYFU, 95%CI 36.0-65.6). The annual incidence of PID hospitalisation temporally related to a chlamydia or gonorrhoea diagnosis was 27.0 (95%CI 24.4-29.8) and 96.6 (95%CI 64.7-138.8) times greater, respectively, than the age-equivalent NSW female population. Younger age, socio-economic disadvantage, having a diagnosis prior to 2005 and having a prior birth were also associated with being hospitalised for PID. Chlamydia and gonorrhoea are both associated with large increases in the risk of PID hospitalisation. Our data suggest the risk of PID hospitalisation is much higher for gonorrhoea than chlamydia; however, further research is needed to confirm this finding.

  9. Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcu, Loredana G., E-mail: loredana@marcunet.com; Faculty of Science, University of Oradea; School of Chemistry and Physics, University of Adelaide, South Australia

    2013-10-01

    Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methodsmore » was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.« less

  10. Profile of the Pediatric Infectious Disease Workforce in 2015.

    PubMed

    Yeh, Sylvia H; Vijayan, Vini; Hahn, Andrea; Ruch-Ross, Holly; Kirkwood, Suzanne; Phillips, Terri Christene; Harrison, Christopher J

    2017-12-22

    Almost 20 years have elapsed since the last workforce survey of pediatric infectious disease (PID) subspecialists was conducted in 1997-1998. The American Academy of Pediatrics Section on Infectious Diseases in collaboration with the Pediatric Infectious Diseases Society sought to assess the status of the current PID workforce. A Web-based survey conducted in 2015 collected data on demographics, practice patterns, and job satisfaction among the PID workforce, and identified factors related to job placement among recent fellowship graduates. Of 946 respondents (48% response rate), 50% were female. The average age was 51 years (range, 29-88 years); 63% were employed by an academic center/hospital, and 85% provided direct patient care; and 18% were not current PID practitioners. Of the 138 (21%) respondents who had completed a PID fellowship within the previous 5 years, 83% applied for <5 PID positions; 43% reported that their first position was created specifically for them; 47% had 1 job offer, and 41% had 2 or 3 job offers; 82% were employed within 6 months; and 74% remained at the institution of their first job. Respondents who were practicing PID full-time or part-time (n = 778) indicated desiring more focused training in immunodeficiencies (31%), transplant-related care (31%), and travel/tropical medicine (28%). Overall, 70% of the respondents would "definitely" or "probably" choose PID again. Most respondents were satisfied with their career choice in PID. Most of the recent fellowship graduates were employed within 6 months after training. We identified potential areas in which the PID community can focus efforts to maintain the pipeline and improve satisfaction among its physicians. © The Author 2017. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. PSO-based PID Speed Control of Traveling Wave Ultrasonic Motor under Temperature Disturbance

    NASA Astrophysics Data System (ADS)

    Arifin Mat Piah, Kamal; Yusoff, Wan Azhar Wan; Azmi, Nur Iffah Mohamed; Romlay, Fadhlur Rahman Mohd

    2018-03-01

    Traveling wave ultrasonic motors (TWUSMs) have a time varying dynamics characteristics. Temperature rise in TWUSMs remains a problem particularly in sustaining optimum speed performance. In this study, a PID controller is used to control the speed of TWUSM under temperature disturbance. Prior to developing the controller, a linear approximation model which relates the speed to the temperature is developed based on the experimental data. Two tuning methods are used to determine PID parameters: conventional Ziegler-Nichols(ZN) and particle swarm optimization (PSO). The comparison of speed control performance between PSO-PID and ZN-PID is presented. Modelling, simulation and experimental work is carried out utilizing Fukoku-Shinsei USR60 as the chosen TWUSM. The results of the analyses and experimental work reveal that PID tuning using PSO-based optimization has the advantage over the conventional Ziegler-Nichols method.

  12. Time-Series INSAR: An Integer Least-Squares Approach For Distributed Scatterers

    NASA Astrophysics Data System (ADS)

    Samiei-Esfahany, Sami; Hanssen, Ramon F.

    2012-01-01

    The objective of this research is to extend the geode- tic mathematical model which was developed for persistent scatterers to a model which can exploit distributed scatterers (DS). The main focus is on the integer least- squares framework, and the main challenge is to include the decorrelation effect in the mathematical model. In order to adapt the integer least-squares mathematical model for DS we altered the model from a single master to a multi-master configuration and introduced the decorrelation effect stochastically. This effect is described in our model by a full covariance matrix. We propose to de- rive this covariance matrix by numerical integration of the (joint) probability distribution function (PDF) of interferometric phases. This PDF is a function of coherence values and can be directly computed from radar data. We show that the use of this model can improve the performance of temporal phase unwrapping of distributed scatterers.

  13. Enhanced index tracking modeling in portfolio optimization with mixed-integer programming z approach

    NASA Astrophysics Data System (ADS)

    Siew, Lam Weng; Jaaman, Saiful Hafizah Hj.; Ismail, Hamizun bin

    2014-09-01

    Enhanced index tracking is a popular form of portfolio management in stock market investment. Enhanced index tracking aims to construct an optimal portfolio to generate excess return over the return achieved by the stock market index without purchasing all of the stocks that make up the index. The objective of this paper is to construct an optimal portfolio using mixed-integer programming model which adopts regression approach in order to generate higher portfolio mean return than stock market index return. In this study, the data consists of 24 component stocks in Malaysia market index which is FTSE Bursa Malaysia Kuala Lumpur Composite Index from January 2010 until December 2012. The results of this study show that the optimal portfolio of mixed-integer programming model is able to generate higher mean return than FTSE Bursa Malaysia Kuala Lumpur Composite Index return with only selecting 30% out of the total stock market index components.

  14. Scattering and cloaking of binary hyper-particles in metamaterials.

    PubMed

    Alexopoulos, A; Yau, K S B

    2010-09-13

    We derive the d-dimensional scattering cross section for homogeneous and composite hyper-particles inside a metamaterial. The polarizability of the hyper-particles is expressed in multi-dimensional form and is used in order to examine various scattering characteristics. We introduce scattering bounds that display interesting results when d --> ∞ and in particular consider the special limit of hyper-particle cloaking in some detail. We demonstrate cloaking via resonance for homogeneous particles and show that composite hyper-particles can be used in order to obtain electromagnetic cloaking with either negative or all positive constitutive parameters respectively. Our approach not only considers cloaking of particles of integer dimension but also particles with non-integer dimension such as fractals. Theoretical results are compared to full-wave numerical simulations for two interacting hyper-particles in a medium.

  15. Research on fuzzy PID control to electronic speed regulator

    NASA Astrophysics Data System (ADS)

    Xu, Xiao-gang; Chen, Xue-hui; Zheng, Sheng-guo

    2007-12-01

    As an important part of diesel engine, the speed regulator plays an important role in stabilizing speed and improving engine's performance. Because there are so many model parameters of diesel-engine considered in traditional PID control and these parameters present non-linear characteristic.The method to adjust engine speed using traditional PID is not considered as a best way. Especially for the diesel-engine generator set. In this paper, the Fuzzy PID control strategy is proposed. Some problems about its utilization in electronic speed regulator are discussed. A mathematical model of electric control system for diesel-engine generator set is established and the way of the PID parameters in the model to affect the function of system is analyzed. And then it is proposed the differential coefficient must be applied in control design for reducing dynamic deviation of system and adjusting time. Based on the control theory, a study combined control with PID calculation together for turning fuzzy PID parameter is implemented. And also a simulation experiment about electronic speed regulator system was conducted using Matlab/Simulink and the Fuzzy-Toolbox. Compared with the traditional PID Algorithm, the simulated results presented obvious improvements in the instantaneous speed governing rate and steady state speed governing rate of diesel-engine generator set when the fuzzy logic control strategy used.

  16. A hybrid intelligent controller for a twin rotor MIMO system and its hardware implementation.

    PubMed

    Juang, Jih-Gau; Liu, Wen-Kai; Lin, Ren-Wei

    2011-10-01

    This paper presents a fuzzy PID control scheme with a real-valued genetic algorithm (RGA) to a setpoint control problem. The objective of this paper is to control a twin rotor MIMO system (TRMS) to move quickly and accurately to the desired attitudes, both the pitch angle and the azimuth angle in a cross-coupled condition. A fuzzy compensator is applied to the PID controller. The proposed control structure includes four PID controllers with independent inputs in 2-DOF. In order to reduce total error and control energy, all parameters of the controller are obtained by a RGA with the system performance index as a fitness function. The system performance index utilized the integral of time multiplied by the square error criterion (ITSE) to build a suitable fitness function in the RGA. A new method for RGA to solve more than 10 parameters in the control scheme is investigated. For real-time control, Xilinx Spartan II SP200 FPGA (Field Programmable Gate Array) is employed to construct a hardware-in-the-loop system through writing VHDL on this FPGA. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Modeling of inter-neuronal coupling medium and its impact on neuronal synchronization

    PubMed Central

    Iqbal, Muhammad; Hong, Keum-Shik

    2017-01-01

    In this paper, modeling of the coupling medium between two neurons, the effects of the model parameters on the synchronization of those neurons, and compensation of coupling strength deficiency in synchronization are studied. Our study exploits the inter-neuronal coupling medium and investigates its intrinsic properties in order to get insight into neuronal-information transmittance and, there from, brain-information processing. A novel electrical model of the coupling medium that represents a well-known RLC circuit attributable to the coupling medium’s intrinsic resistive, inductive, and capacitive properties is derived. Surprisingly, the integration of such properties reveals the existence of a natural three-term control strategy, referred to in the literature as the proportional integral derivative (PID) controller, which can be responsible for synchronization between two neurons. Consequently, brain-information processing can rely on a large number of PID controllers based on the coupling medium properties responsible for the coherent behavior of neurons in a neural network. Herein, the effects of the coupling model (or natural PID controller) parameters are studied and, further, a supervisory mechanism is proposed that follows a learning and adaptation policy based on the particle swarm optimization algorithm for compensation of the coupling strength deficiency. PMID:28486505

  18. High field ESR study of the pi-d interaction effect in beta-(BDA-TTP)2MCl4 (M=Fe, Ga)

    NASA Astrophysics Data System (ADS)

    Tokumoto, Takahisa; Vantol, J.; Brunel, L.-C.; Choi, E. S.; Brooks, J. S.; Kaihatsu, T.; Akutsu, H.; Yamada, J.

    2007-03-01

    Novel magnetic organic conductors with pi-d interaction have commanded attention since the discovery of field induced superconductivity. One of them, beta-(BDA-TTP)2FeCl4, has alternating donor molecules and quasi 2D electrical properties. Previous studies of electrical and magnetic properties show an M-I transition at 120K and an AF transition at TN=8.5K, suggesting an exchange interaction between the conduction electrons and the Fe^3+ d-electrons. The properties of beta-(BDA-TTP)2GaCl4 are similar with exception of the absence of the AF transition, which is apparently due to the absence of pi-d exchange interaction. We report angular/temperature dependent 240GHz quasi optical ESR measurements on both compounds to probe the magnetic properties. The Ga compound signals follow the donor molecule structure, and show no magnetic order at any temperature. The Fe compound signals are quite different from the Ga compound, and exhibit AF behavior below TN. The difference of Fe and Ga compounds will be discussed in terms of the interaction between localized and itinerant magnetic moments.

  19. The maladaptive personality traits of the Personality Inventory for DSM-5 (PID-5) in relation to the HEXACO personality factors and schizotypy/dissociation.

    PubMed

    Ashton, Michael C; Lee, Kibeom; de Vries, Reinout E; Hendrickse, Joshua; Born, Marise Ph

    2012-10-01

    The Personality Inventory for DSM-5 (PID-5), a new measure of maladaptive personality traits, has recently been developed by the DSM-5 Personality and Personality Disorders Workgroup. The PID-5 variables were examined within the seven-factor space defined by the six HEXACO factors and the Schizotypy/Dissociation factor (Ashton & Lee, 2012) using participant samples from Canada (N = 378) and the Netherlands (N = 476). Extension analyses showed that several PID-5 facet-level scales represented each of the Honesty-Humility, Emotionality, Extraversion, Conscientiousness, and Schizotypy/Dissociation factors. In contrast, only one PID-5 scale loaded strongly on HEXACO Agreeableness, and no PID-5 scales loaded strongly on Openness to Experience. In addition, a joint factor analysis involving the PID-5 variables and facets of the Five-Factor Model was conducted in the Canadian sample and recovered a set of seven factors corresponding rather closely to the HEXACO factors plus Schizotypy/Dissociation. The authors discuss implications for the assessment and structure of normal and abnormal personality.

  20. What is the Value Proposition of Persistent Identifiers?

    NASA Astrophysics Data System (ADS)

    Klump, Jens; Huber, Robert

    2017-04-01

    Persistent identifiers (PID) are widely used today in scientific communication and documentation. Global unique identification plus persistent resolution of links to referenced digital research objects have been strong selling points for PID Systems as enabling technical infrastructures. Novel applications of PID Systems in research now go beyond the identification of file based objects such as literature or data sets and include the identification of dynamically changing datasets accessed through web services, physical objects, persons and organisations. But not only do we see more use cases but also a proliferation of identifier systems. An analysis of PID Systems used by 1381 repositories listed in the Registry of Research Data Repositories (re3data.org, status of 14 Dec 2015) showed that many disciplinary data repositories make use of PID that are not among the systems promoted by the libraries and publishers (DOI, PURL, ARK). This indicates that a number of communities have developed their own PID Systems. This begs the question, do we need more identifier systems? What makes their value proposition more appealing than those of already existing systems? On the other hand, some of these new use cases deal with entities outside the digital domain, the original scope of application for PIDs. It is therefore necessary to critically appraise the value propositions of available PID Systems and compare these against the requirements of new use cases for PID. Undoubtedly, DOI are the most used persistent identifier in scholarly communication. It was originally designed "to link customers with publishers, facilitate electronic commerce, and enable copyright management systems." Today, the DOI system is described as providing "a technical and social infrastructure for the registration and use of persistent interoperable identifiers for use on digital networks". This example shows how value propositions can change over time. Additional value can be gained by cross-linking between PID Systems, thus allowing new scholarly documentation and evaluation methods such as documenting the track record of researchers in publications and successful funding proposals, apply advanced bibliometric approaches, estimate the output and impact of funding, assess the reuse and subsequent impact of data publications, demonstrate the efficient use of research infrastructures, etc. This recombination of systems raise a series of new expectations and each stakeholder group may have its own vision of the benefits and value proposition of PIDs, which might be in conflict with others. New PID applications will arise with the application of PID Systems to semantic web technologies and to the Internet of Things, which extend PID applications to beyond digital objects to concepts and things, respectively, raising yet again their own expectations and value propositions. What are we trying to identify? What is the purpose served by identifying it? What are the implications for semantic web technologies? How certain can we be about the identity of an object and its state changes over time (Ship of Theseus Paradox)? In this presentation we will discuss a number of PID use cases and match these against the value propositions offered by a selection of PID Systems.

  1. PID Tuning Using Extremum Seeking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Killingsworth, N; Krstic, M

    2005-11-15

    Although proportional-integral-derivative (PID) controllers are widely used in the process industry, their effectiveness is often limited due to poor tuning. Manual tuning of PID controllers, which requires optimization of three parameters, is a time-consuming task. To remedy this difficulty, much effort has been invested in developing systematic tuning methods. Many of these methods rely on knowledge of the plant model or require special experiments to identify a suitable plant model. Reviews of these methods are given in [1] and the survey paper [2]. However, in many situations a plant model is not known, and it is not desirable to openmore » the process loop for system identification. Thus a method for tuning PID parameters within a closed-loop setting is advantageous. In relay feedback tuning [3]-[5], the feedback controller is temporarily replaced by a relay. Relay feedback causes most systems to oscillate, thus determining one point on the Nyquist diagram. Based on the location of this point, PID parameters can be chosen to give the closed-loop system a desired phase and gain margin. An alternative tuning method, which does not require either a modification of the system or a system model, is unfalsified control [6], [7]. This method uses input-output data to determine whether a set of PID parameters meets performance specifications. An adaptive algorithm is used to update the PID controller based on whether or not the controller falsifies a given criterion. The method requires a finite set of candidate PID controllers that must be initially specified [6]. Unfalsified control for an infinite set of PID controllers has been developed in [7]; this approach requires a carefully chosen input signal [8]. Yet another model-free PID tuning method that does not require opening of the loop is iterative feedback tuning (IFT). IFT iteratively optimizes the controller parameters with respect to a cost function derived from the output signal of the closed-loop system, see [9]. This method is based on the performance of the closed-loop system during a step response experiment [10], [11]. In this article we present a method for optimizing the step response of a closed-loop system consisting of a PID controller and an unknown plant with a discrete version of extremum seeking (ES). Specifically, ES is used to minimize a cost function similar to that used in [10], [11], which quantifies the performance of the PID controller. ES, a non-model-based method, iteratively modifies the arguments (in this application the PID parameters) of a cost function so that the output of the cost function reaches a local minimum or local maximum. In the next section we apply ES to PID controller tuning. We illustrate this technique through simulations comparing the effectiveness of ES to other PID tuning methods. Next, we address the importance of the choice of cost function and consider the effect of controller saturation. Furthermore, we discuss the choice of ES tuning parameters. Finally, we offer some conclusions.« less

  2. Equilibrium points, stability and numerical solutions of fractional-order predator-prey and rabies models

    NASA Astrophysics Data System (ADS)

    Ahmed, E.; El-Sayed, A. M. A.; El-Saka, H. A. A.

    2007-01-01

    In this paper we are concerned with the fractional-order predator-prey model and the fractional-order rabies model. Existence and uniqueness of solutions are proved. The stability of equilibrium points are studied. Numerical solutions of these models are given. An example is given where the equilibrium point is a centre for the integer order system but locally asymptotically stable for its fractional-order counterpart.

  3. Potential-Induced Degradation-Delamination Mode in Crystalline Silicon Modules: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacke, Peter L; Kempe, Michael D; Wohlgemuth, John

    A test sequence producing potential-induced degradation-delamination (PID-d) in crystalline silicon modules has been tested and found comparable under visual inspection to cell/encapsulant delamination seen in some fielded modules. Four commercial modules were put through this sequence, 85 degrees C, 85%, 1000 h damp heat, followed by an intensive PID stress sequence of 72 degrees C, 95% RH, and -1000 V, with the module face grounded using a metal foil. The 60 cell c-Si modules exhibiting the highest current transfer (4.4 center dot 10-4 A) exhibited PID-d at the first inspection after 156 h of PID stress. Effects promoting PID-d aremore » reduced adhesion caused by damp heat, sodium migration further reducing adhesion to the cells, and gaseous products of electrochemical reactions driven by the applied system voltage. A new work item proposal for an IEC test standard to evaluate for PID-d is anticipated.« less

  4. Cost-effectiveness of alternative outpatient pelvic inflammatory disease treatment strategies.

    PubMed

    Smith, Kenneth J; Ness, Roberta B; Wiesenfeld, Harold C; Roberts, Mark S

    2007-12-01

    Effectiveness differences between outpatient pelvic inflammatory disease (PID) treatment regimens are uncertain, but significant differences in cost exist. To examine the influence of antibiotic costs on PID therapy cost-effectiveness. The authors used a Markov decision model to estimate the cost-effectiveness of recommended antibiotic regimens for PID and performed a value of information analysis to guide future research. Antibiotic costs vary between USD 43 and USD188. Pairwise comparisons, assuming a hypothetical 1% relative risk reduction in PID complications with the more expensive regimen, showed economically reasonable cost-effectiveness ratios. Value of information and sample size considerations support further investigation to detect 10% PID complication rate differences between regimens with >or=USD 50 cost differences. Within the cost range of recommended regimens, use of more expensive antibiotics would be economically reasonable if relatively small decreases in PID complication rates exist. Further investigation of effectiveness differences between regimens is needed.

  5. Cascade control of superheated steam temperature with neuro-PID controller.

    PubMed

    Zhang, Jianhua; Zhang, Fenfang; Ren, Mifeng; Hou, Guolian; Fang, Fang

    2012-11-01

    In this paper, an improved cascade control methodology for superheated processes is developed, in which the primary PID controller is implemented by neural networks trained by minimizing error entropy criterion. The entropy of the tracking error can be estimated recursively by utilizing receding horizon window technique. The measurable disturbances in superheated processes are input to the neuro-PID controller besides the sequences of tracking error in outer loop control system, hence, feedback control is combined with feedforward control in the proposed neuro-PID controller. The convergent condition of the neural networks is analyzed. The implementation procedures of the proposed cascade control approach are summarized. Compared with the neuro-PID controller using minimizing squared error criterion, the proposed neuro-PID controller using minimizing error entropy criterion may decrease fluctuations of the superheated steam temperature. A simulation example shows the advantages of the proposed method. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  6. PID Controller Settings Based on a Transient Response Experiment

    ERIC Educational Resources Information Center

    Silva, Carlos M.; Lito, Patricia F.; Neves, Patricia S.; Da Silva, Francisco A.

    2008-01-01

    An experimental work on controller tuning for chemical engineering undergraduate students is proposed using a small heat exchange unit. Based upon process reaction curves in open-loop configuration, system gain and time constant are determined for first order model with time delay with excellent accuracy. Afterwards students calculate PID…

  7. Increased risk of borderline ovarian tumors in women with a history of pelvic inflammatory disease: A nationwide population-based cohort study.

    PubMed

    Rasmussen, Christina B; Jensen, Allan; Albieri, Vanna; Andersen, Klaus K; Kjaer, Susanne K

    2016-11-01

    Some studies suggest that pelvic inflammatory disease (PID) is a potential risk factor for ovarian cancer. However, only few studies have investigated the association between PID and risk of borderline ovarian tumors. We conducted a population-based cohort study to investigate the association between PID and risk of borderline ovarian tumors. Using various nationwide Danish registries we identified all women in Denmark during 1978-2012, who were born during 1940-1970 (n=1,318,925). Of these, 81,263 women were diagnosed with PID in the study period, and 2736 women had a borderline ovarian tumor (1290 serous and 1344 mucinous). Hazard ratios (HRs) and 95% confidence intervals (CIs) for the association between PID and risk of borderline tumors were estimated using Cox regression models with adjustment for potential confounders. A history of PID was associated with an increased risk of borderline ovarian tumors (HR=1.39; 95% CI: 1.19-1.61). However, histotype-specific analyses revealed significant variation in risk as PID was only associated with an increased risk of serous borderline tumors (HR=1.85; 95% CI: 1.52-2.24), but not with mucinous borderline tumors (HR=1.06; 95% CI: 0.83-1.35). PID is associated with an increased risk of serous borderline tumors. Further research on the potential underlying biological mechanisms and on the identification of the subset of women with PID who are at increased risk of serous borderline tumors is warranted. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Pelvic Inflammatory Disease and the Risk of Ovarian Cancer and Borderline Ovarian Tumors: A Pooled Analysis of 13 Case-Control Studies

    PubMed Central

    Rasmussen, Christina B.; Kjaer, Susanne K.; Albieri, Vanna; Bandera, Elisa V.; Doherty, Jennifer A.; Høgdall, Estrid; Webb, Penelope M.; Jordan, Susan J.; Rossing, Mary Anne; Wicklund, Kristine G.; Goodman, Marc T.; Modugno, Francesmary; Moysich, Kirsten B.; Ness, Roberta B.; Edwards, Robert P.; Schildkraut, Joellen M.; Berchuck, Andrew; Olson, Sara H.; Kiemeney, Lambertus A.; Massuger, Leon F. A. G.; Narod, Steven A.; Phelan, Catherine M.; Anton-Culver, Hoda; Ziogas, Argyrios; Wu, Anna H.; Pearce, Celeste L.; Risch, Harvey A.; Jensen, Allan

    2017-01-01

    Inflammation has been implicated in ovarian carcinogenesis. However, studies investigating the association between pelvic inflammatory disease (PID) and ovarian cancer risk are few and inconsistent. We investigated the association between PID and the risk of epithelial ovarian cancer according to tumor behavior and histotype. We pooled data from 13 case-control studies, conducted between 1989 and 2009, from the Ovarian Cancer Association Consortium (OCAC), including 9,162 women with ovarian cancers, 2,354 women with borderline tumors, and 14,736 control participants. Study-specific odds ratios were estimated and subsequently combined into a pooled odds ratio using a random-effects model. A history of PID was associated with an increased risk of borderline tumors (pooled odds ratio (pOR) = 1.32, 95% confidence interval (CI): 1.10, 1.58). Women with at least 2 episodes of PID had a 2-fold increased risk of borderline tumors (pOR = 2.14, 95% CI: 1.08, 4.24). No association was observed between PID and ovarian cancer risk overall (pOR = 0.99, 95% CI: 0.83, 1.19); however, a statistically nonsignificantly increased risk of low-grade serous tumors (pOR = 1.48, 95% CI: 0.92, 2.38) was noted. In conclusion, PID was associated with an increased risk of borderline ovarian tumors, particularly among women who had had multiple episodes of PID. Although our results indicated a histotype-specific association with PID, the association of PID with ovarian cancer risk is still somewhat uncertain and requires further investigation. PMID:27941069

  9. A low power flash-FPGA based brain implant micro-system of PID control.

    PubMed

    Lijuan Xia; Fattah, Nabeel; Soltan, Ahmed; Jackson, Andrew; Chester, Graeme; Degenaar, Patrick

    2017-07-01

    In this paper, we demonstrate that a low power flash FPGA based micro-system can provide a low power programmable interface for closed-loop brain implant inter- faces. The proposed micro-system receives recording local field potential (LFP) signals from an implanted probe, performs closed-loop control using a first order control system, then converts the signal into an optogenetic control stimulus pattern. Stimulus can be implemented through optoelectronic probes. The long term target is for both fundamental neuroscience applications and for clinical use in treating epilepsy. Utilizing our device, closed-loop processing consumes only 14nJ of power per PID cycle compared to 1.52μJ per cycle for a micro-controller implementation. Compared to an application specific digital integrated circuit, flash FPGA's are inherently programmable.

  10. The ESID Online Database network.

    PubMed

    Guzman, D; Veit, D; Knerr, V; Kindle, G; Gathmann, B; Eades-Perner, A M; Grimbacher, B

    2007-03-01

    Primary immunodeficiencies (PIDs) belong to the group of rare diseases. The European Society for Immunodeficiencies (ESID), is establishing an innovative European patient and research database network for continuous long-term documentation of patients, in order to improve the diagnosis, classification, prognosis and therapy of PIDs. The ESID Online Database is a web-based system aimed at data storage, data entry, reporting and the import of pre-existing data sources in an enterprise business-to-business integration (B2B). The online database is based on Java 2 Enterprise System (J2EE) with high-standard security features, which comply with data protection laws and the demands of a modern research platform. The ESID Online Database is accessible via the official website (http://www.esid.org/). Supplementary data are available at Bioinformatics online.

  11. Decentralized PID controller for TITO systems using characteristic ratio assignment with an experimental application.

    PubMed

    Hajare, V D; Patre, B M

    2015-11-01

    This paper presents a decentralized PID controller design method for two input two output (TITO) systems with time delay using characteristic ratio assignment (CRA) method. The ability of CRA method to design controller for desired transient response has been explored for TITO systems. The design methodology uses an ideal decoupler to reduce the interaction. Each decoupled subsystem is reduced to first order plus dead time (FOPDT) model to design independent diagonal controllers. Based on specified overshoot and settling time, the controller parameters are computed using CRA method. To verify performance of the proposed controller, two benchmark simulation examples are presented. To demonstrate applicability of the proposed controller, experimentation is performed on real life interacting coupled tank level system. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  12. Tuning and performance evaluation of PID controller for superheater steam temperature control of 200 MW boiler using gain phase assignment algorithm

    NASA Astrophysics Data System (ADS)

    Begum, A. Yasmine; Gireesh, N.

    2018-04-01

    In superheater, steam temperature is controlled in a cascade control loop. The cascade control loop consists of PI and PID controllers. To improve the superheater steam temperature control the controller's gains in a cascade control loop has to be tuned efficiently. The mathematical model of the superheater is derived by sets of nonlinear partial differential equations. The tuning methods taken for study here are designed for delay plus first order transfer function model. Hence from the dynamical model of the superheater, a FOPTD model is derived using frequency response method. Then by using Chien-Hrones-Reswick Tuning Algorithm and Gain-Phase Assignment Algorithm optimum controller gains has been found out based on the least value of integral time weighted absolute error.

  13. Development of a Clear Fiber Cherenkov Counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaneko, N.; Han, S.; Ito, H.

    2015-07-01

    We have developed a new PID detector consists of clear fibers. PID efficiency was measured with 470 MeV e{sup +} beam. As a result, this detector with thickness of 5 cm has the PID efficiency of 95 %. (authors)

  14. TOXIRAE PRO PID

    EPA Science Inventory

    The ToxiRAE Pro PID measures total volatile organic compounds (VOCs) using a photoionization detector (PID). This sensor can be programmed to measure concentrations of a specified compound automatically and has a real time reading of VOC concentrations in parts per million (ppm) ...

  15. Determination of optimum values for maximizing the profit in bread production: Daily bakery Sdn Bhd

    NASA Astrophysics Data System (ADS)

    Muda, Nora; Sim, Raymond

    2015-02-01

    An integer programming problem is a mathematical optimization or feasibility program in which some or all of the variables are restricted to be integers. In many settings the term refers to integer linear programming (ILP), in which the objective function and the constraints (other than the integer constraints) are linear. An ILP has many applications in industrial production, including job-shop modelling. A possible objective is to maximize the total production, without exceeding the available resources. In some cases, this can be expressed in terms of a linear program, but variables must be constrained to be integer. It concerned with the optimization of a linear function while satisfying a set of linear equality and inequality constraints and restrictions. It has been used to solve optimization problem in many industries area such as banking, nutrition, agriculture, and bakery and so on. The main purpose of this study is to formulate the best combination of all ingredients in producing different type of bread in Daily Bakery in order to gain maximum profit. This study also focuses on the sensitivity analysis due to changing of the profit and the cost of each ingredient. The optimum result obtained from QM software is RM 65,377.29 per day. This study will be benefited for Daily Bakery and also other similar industries. By formulating a combination of all ingredients make up, they can easily know their total profit in producing bread everyday.

  16. The use of integer programming to select bulls across breeding companies with volume price discounts.

    PubMed

    McConnel, M B; Galligan, D T

    2004-10-01

    Optimization programs are currently used to aid in the selection of bulls to be used in herd breeding programs. While these programs offer a systematic approach to the problem of semen selection, they ignore the impact of volume discounts. Volume discounts are discounts that vary depending on the number of straws purchased. The dynamic nature of volume discounts means that, in order to be adequately accounted for, they must be considered in the optimization routine. Failing to do this creates a missed economic opportunity because the potential benefits of optimally selecting and combining breeding company discount opportunities are not captured. To address these issues, an integer program was created which used binary decision variables to incorporate the effects of quantity discounts into the optimization program. A consistent set of trait criteria was used to select a group of bulls from 3 sample breeding companies. Three different selection programs were used to select the bulls, 2 traditional methods and the integer method. After the discounts were applied using each method, the integer program resulted in the lowest cost portfolio of bulls. A sensitivity analysis showed that the integer program also resulted in a low cost portfolio when the genetic trait goals were changed to be more or less stringent. In the sample application, a net benefit of the new approach over the traditional approaches was a 12.3 to 20.0% savings in semen cost.

  17. Educational paper

    PubMed Central

    de Vries, Esther

    2010-01-01

    Primary immunodeficiencies (PIDs) are characterized by an increased susceptibility to infections due to defects in one ore more components of the immune system. Although most PIDs are relatively rare, they are more frequent than generally acknowledged. Early diagnosis and treatment of PIDs save lives, prevent morbidity, and improve quality of life. This early diagnosis is the task of the pediatrician who encounters the child for the first time: he/she should suspect potential PID in time and perform the appropriate diagnostic tests. In this educational paper, the first in a series of five, we will describe the most common clinical presentations of PIDs and offer guidelines for the diagnostic process, as well as a brief overview of therapeutic possibilities and prognosis. PMID:21170549

  18. Modeling an integrated hospital management planning problem using integer optimization approach

    NASA Astrophysics Data System (ADS)

    Sitepu, Suryati; Mawengkang, Herman; Irvan

    2017-09-01

    Hospital is a very important institution to provide health care for people. It is not surprising that nowadays the people’s demands for hospital is increasing. However, due to the rising cost of healthcare services, hospitals need to consider efficiencies in order to overcome these two problems. This paper deals with an integrated strategy of staff capacity management and bed allocation planning to tackle these problems. Mathematically, the strategy can be modeled as an integer linear programming problem. We solve the model using a direct neighborhood search approach, based on the notion of superbasic variables.

  19. Stability Analysis of Distributed Order Fractional Chen System

    PubMed Central

    Aminikhah, H.; Refahi Sheikhani, A.; Rezazadeh, H.

    2013-01-01

    We first investigate sufficient and necessary conditions of stability of nonlinear distributed order fractional system and then we generalize the integer-order Chen system into the distributed order fractional domain. Based on the asymptotic stability theory of nonlinear distributed order fractional systems, the stability of distributed order fractional Chen system is discussed. In addition, we have found that chaos exists in the double fractional order Chen system. Numerical solutions are used to verify the analytical results. PMID:24489508

  20. Simultaneous gains tuning in boiler/turbine PID-based controller clusters using iterative feedback tuning methodology.

    PubMed

    Zhang, Shu; Taft, Cyrus W; Bentsman, Joseph; Hussey, Aaron; Petrus, Bryan

    2012-09-01

    Tuning a complex multi-loop PID based control system requires considerable experience. In today's power industry the number of available qualified tuners is dwindling and there is a great need for better tuning tools to maintain and improve the performance of complex multivariable processes. Multi-loop PID tuning is the procedure for the online tuning of a cluster of PID controllers operating in a closed loop with a multivariable process. This paper presents the first application of the simultaneous tuning technique to the multi-input-multi-output (MIMO) PID based nonlinear controller in the power plant control context, with the closed-loop system consisting of a MIMO nonlinear boiler/turbine model and a nonlinear cluster of six PID-type controllers. Although simplified, the dynamics and cross-coupling of the process and the PID cluster are similar to those used in a real power plant. The particular technique selected, iterative feedback tuning (IFT), utilizes the linearized version of the PID cluster for signal conditioning, but the data collection and tuning is carried out on the full nonlinear closed-loop system. Based on the figure of merit for the control system performance, the IFT is shown to deliver performance favorably comparable to that attained through the empirical tuning carried out by an experienced control engineer. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Development and validation of an Overreporting Scale for the Personality Inventory for DSM-5 (PID-5).

    PubMed

    Sellbom, Martin; Dhillon, Sonya; Bagby, R Michael

    2018-05-01

    Our aim in the current study was to develop a validity scale for the Personality Inventory for DSM-5 (PID-5) to detect noncredible overreported responding. To this end, we used a rare symptoms approach and identified extreme response options on PID-5 items that were infrequently endorsed by students in 3 different university samples (N = 1,370) and in a psychiatric patient sample (N = 194). The resulting 10-item scale (the PID-5-ORS) produced adequate-to-good estimates of internal reliability and was significantly correlated with the Minnesota Multiphasic Personality Inventory-2 Restructued Form (MMPI-2-RF) overreporting validity scales, providing evidence of concurrent validity. The criterion validity of the PID-5-ORS was demonstrated in an analog simulation design study. More specifically, university students instructed to overreport (n = 80) scored substantially higher on the PID-5-ORS relative to both a group of genuine psychiatric patients and students instructed to complete the PID-5 under standard (honest) instructions (n = 161); the effect size magnitudes associated with these differences were large. Classification accuracy analyses further revealed that high scores on the PID-5-ORS were associated with high specificity (and thus, low rates of false positive classifications) in differentiating overreporters from genuine patients, with sensitivity being somewhat weaker. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  2. A novel auto-tuning PID control mechanism for nonlinear systems.

    PubMed

    Cetin, Meric; Iplikci, Serdar

    2015-09-01

    In this paper, a novel Runge-Kutta (RK) discretization-based model-predictive auto-tuning proportional-integral-derivative controller (RK-PID) is introduced for the control of continuous-time nonlinear systems. The parameters of the PID controller are tuned using RK model of the system through prediction error-square minimization where the predicted information of tracking error provides an enhanced tuning of the parameters. Based on the model-predictive control (MPC) approach, the proposed mechanism provides necessary PID parameter adaptations while generating additive correction terms to assist the initially inadequate PID controller. Efficiency of the proposed mechanism has been tested on two experimental real-time systems: an unstable single-input single-output (SISO) nonlinear magnetic-levitation system and a nonlinear multi-input multi-output (MIMO) liquid-level system. RK-PID has been compared to standard PID, standard nonlinear MPC (NMPC), RK-MPC and conventional sliding-mode control (SMC) methods in terms of control performance, robustness, computational complexity and design issue. The proposed mechanism exhibits acceptable tuning and control performance with very small steady-state tracking errors, and provides very short settling time for parameter convergence. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Status of adolescent pelvic inflammatory disease management in the United States.

    PubMed

    Trent, Maria

    2013-10-01

    Pelvic inflammatory disease (PID) is a common and serious reproductive health disorder and disease rates remain unacceptably high among adolescent girls and young adult women in the United States. Despite data demonstrating that women experience major adverse health outcomes after PID, national recommendations for management of adolescents have become increasingly less cautious in an era of cost-containment. In this review, we take an alternative look at published data on adolescents with PID to frame the next steps for optimizing management for this vulnerable population. Several findings emerge from review of the literature. First, there is limited evidence to guide the best practice strategies for adolescents with PID due to low enrolment of early and middle adolescents in national trials. Second, adolescents and adult women in the United States receive suboptimal treatment regimens per Centers for Disease Control and Prevention (CDC) standards. Third, available evidence suggests that adolescents are at an increased risk for poor adherence to CDC recommendations for self-care, reacquisition of sexually transmitted infections (STIs) and PID, and subsequent adverse reproductive health outcomes. Efforts to develop and integrate adolescent-focused, evidence-based strategies for PID management and prevention of subsequent STIs and recurrent PID are warranted.

  4. Pelvic inflammatory disease.

    PubMed

    Soper, David E

    2010-08-01

    Pelvic inflammatory disease (PID) is an infection-caused inflammatory continuum from the cervix to the peritoneal cavity. Most importantly, it is associated with fallopian tube inflammation, which can lead to infertility, ectopic pregnancy, and chronic pelvic pain. The microbial etiology is linked to sexually transmitted microorganisms, including Chlamydia trachomatis, Neisseria gonorrheae, Mycoplasma genitalium, and bacterial vaginosis-associated microorganisms, predominantly anaerobes. Pelvic pain and fever are commonly absent in women with confirmed PID. Clinicians should consider milder symptoms such as abnormal vaginal discharge, metrorrhagia, postcoital bleeding, and urinary frequency as potential symptoms associated with the disease, particularly in women at risk of sexually transmitted infection. The diagnosis of PID is based on the findings of lower genital tract inflammation associated with pelvic organ tenderness. The outpatient treatment of mild-to-moderate PID should include tolerated antibiotic regimens with activity against the commonly isolated microorganisms associated with PID and usually consists of an extended spectrum cephalosporin in conjunction with either doxycycline or azithromycin. Clinically severe PID should prompt hospitalization and imaging to rule out a tuboovarian abscess. Parenteral broad-spectrum antibiotic therapy with activity against a polymicrobial flora, particularly gram-negative aerobes and anaerobes, should be implemented. Screening for and treatment of Chlamydia infection can prevent PID.

  5. Two-dimensional mesh embedding for Galerkin B-spline methods

    NASA Technical Reports Server (NTRS)

    Shariff, Karim; Moser, Robert D.

    1995-01-01

    A number of advantages result from using B-splines as basis functions in a Galerkin method for solving partial differential equations. Among them are arbitrary order of accuracy and high resolution similar to that of compact schemes but without the aliasing error. This work develops another property, namely, the ability to treat semi-structured embedded or zonal meshes for two-dimensional geometries. This can drastically reduce the number of grid points in many applications. Both integer and non-integer refinement ratios are allowed. The report begins by developing an algorithm for choosing basis functions that yield the desired mesh resolution. These functions are suitable products of one-dimensional B-splines. Finally, test cases for linear scalar equations such as the Poisson and advection equation are presented. The scheme is conservative and has uniformly high order of accuracy throughout the domain.

  6. Pelvic Inflammatory Disease and the Risk of Ovarian Cancer and Borderline Ovarian Tumors: A Pooled Analysis of 13 Case-Control Studies.

    PubMed

    Rasmussen, Christina B; Kjaer, Susanne K; Albieri, Vanna; Bandera, Elisa V; Doherty, Jennifer A; Høgdall, Estrid; Webb, Penelope M; Jordan, Susan J; Rossing, Mary Anne; Wicklund, Kristine G; Goodman, Marc T; Modugno, Francesmary; Moysich, Kirsten B; Ness, Roberta B; Edwards, Robert P; Schildkraut, Joellen M; Berchuck, Andrew; Olson, Sara H; Kiemeney, Lambertus A; Massuger, Leon F A G; Narod, Steven A; Phelan, Catherine M; Anton-Culver, Hoda; Ziogas, Argyrios; Wu, Anna H; Pearce, Celeste L; Risch, Harvey A; Jensen, Allan

    2017-01-01

    Inflammation has been implicated in ovarian carcinogenesis. However, studies investigating the association between pelvic inflammatory disease (PID) and ovarian cancer risk are few and inconsistent. We investigated the association between PID and the risk of epithelial ovarian cancer according to tumor behavior and histotype. We pooled data from 13 case-control studies, conducted between 1989 and 2009, from the Ovarian Cancer Association Consortium (OCAC), including 9,162 women with ovarian cancers, 2,354 women with borderline tumors, and 14,736 control participants. Study-specific odds ratios were estimated and subsequently combined into a pooled odds ratio using a random-effects model. A history of PID was associated with an increased risk of borderline tumors (pooled odds ratio (pOR) = 1.32, 95% confidence interval (CI): 1.10, 1.58). Women with at least 2 episodes of PID had a 2-fold increased risk of borderline tumors (pOR = 2.14, 95% CI: 1.08, 4.24). No association was observed between PID and ovarian cancer risk overall (pOR = 0.99, 95% CI: 0.83, 1.19); however, a statistically nonsignificantly increased risk of low-grade serous tumors (pOR = 1.48, 95% CI: 0.92, 2.38) was noted. In conclusion, PID was associated with an increased risk of borderline ovarian tumors, particularly among women who had had multiple episodes of PID. Although our results indicated a histotype-specific association with PID, the association of PID with ovarian cancer risk is still somewhat uncertain and requires further investigation. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Exploring the association between resistance and outpatient antibiotic use expressed as DDDs or packages.

    PubMed

    Bruyndonckx, Robin; Hens, Niel; Aerts, Marc; Goossens, Herman; Cortiñas Abrahantes, José; Coenen, Samuel

    2015-04-01

    The objective of this study was to explore the association between resistance and outpatient antibiotic use, expressed as either DDDs per 1000 inhabitants per day (DID) or packages per 1000 inhabitants per day (PID). IMS Health data on outpatient penicillin and cephalosporin (β-lactam) and tetracycline, macrolide, lincosamide and streptogramin (TMLS) use, aggregated at the level of the active substance (WHO version 2011) expressed as DID and PID (2000-07) were linked to European Antimicrobial Resistance Surveillance System (EARSS) data on proportions of penicillin-non-susceptible Streptococcus pneumoniae (PNSP) and erythromycin-non-susceptible S. pneumoniae (ENSP) (2000-09). Combined data for 27 European countries were analysed with a generalized linear mixed model. Model fit for use in DID, PID or both and 0, 1 or 2 year time lags between use and resistance was assessed and predictions of resistance were made for decreasing use expressed as DID, PID or both. When exploring the association between β-lactam use and PNSP, the best model fit was obtained for use in PID without time lag. For the association between TMLS use and ENSP, the best model fit was obtained for use in both PID and DID with a 1 year time lag. PNSP and ENSP are predicted to decrease when use decreases in PID, but not when use decreases in DID. Associations between outpatient antibiotic use and resistance and predictions of resistance were inconsistent whether expressing antibiotic use as DID or PID. We recommend that data on antibiotic use be expressed as PID and that time lags between use and resistance be considered when exploring these associations. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. Atmospheric Turbulence Modeling for Aerospace Vehicles: Fractional Order Fit

    NASA Technical Reports Server (NTRS)

    Kopasakis, George (Inventor)

    2015-01-01

    An improved model for simulating atmospheric disturbances is disclosed. A scale Kolmogorov spectral may be scaled to convert the Kolmogorov spectral into a finite energy von Karman spectral and a fractional order pole-zero transfer function (TF) may be derived from the von Karman spectral. Fractional order atmospheric turbulence may be approximated with an integer order pole-zero TF fit, and the approximation may be stored in memory.

  9. Anti-windup adaptive PID control design for a class of uncertain chaotic systems with input saturation.

    PubMed

    Tahoun, A H

    2017-01-01

    In this paper, the stabilization problem of actuators saturation in uncertain chaotic systems is investigated via an adaptive PID control method. The PID control parameters are auto-tuned adaptively via adaptive control laws. A multi-level augmented error is designed to account for the extra terms appearing due to the use of PID and saturation. The proposed control technique uses both the state-feedback and the output-feedback methodologies. Based on Lyapunov׳s stability theory, new anti-windup adaptive controllers are proposed. Demonstrative examples with MATLAB simulations are studied. The simulation results show the efficiency of the proposed adaptive PID controllers. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  10. FPGA Implementation of Optimal 3D-Integer DCT Structure for Video Compression

    PubMed Central

    2015-01-01

    A novel optimal structure for implementing 3D-integer discrete cosine transform (DCT) is presented by analyzing various integer approximation methods. The integer set with reduced mean squared error (MSE) and high coding efficiency are considered for implementation in FPGA. The proposed method proves that the least resources are utilized for the integer set that has shorter bit values. Optimal 3D-integer DCT structure is determined by analyzing the MSE, power dissipation, coding efficiency, and hardware complexity of different integer sets. The experimental results reveal that direct method of computing the 3D-integer DCT using the integer set [10, 9, 6, 2, 3, 1, 1] performs better when compared to other integer sets in terms of resource utilization and power dissipation. PMID:26601120

  11. The DSM-5 Trait Measure in a Psychiatric Sample of Late Adolescents and Emerging Adults: Structure, Reliability, and Validity.

    PubMed

    De Caluwé, Elien; Verbeke, Lize; van Aken, Marcel; van der Heijden, Paul T; De Clercq, Barbara

    2018-02-22

    The inclusion of a dimensional trait model of personality pathology in DSM-5 creates new opportunities for research on developmental antecedents of personality pathology. The traits of this model can be measured with the Personality Inventory for DSM-5 (PID-5), initially developed for adults, but also demonstrating validity in adolescents. The present study adds to the growing body of literature on the psychometrics of the PID-5, by examining its structure, validity, and reliability in 187 psychiatric-referred late adolescents and emerging adults. PID-5, Big Five Inventory, and Kidscreen self-reports were provided, and 88 non-clinical matched controls completed the PID-5. Results confirm the PID-5's five-factor structure, indicate adequate psychometric properties, and underscore the construct and criterion validity, showing meaningful associations with adaptive traits and quality of life. Results are discussed in terms of the PID-5's applicability in vulnerable populations who are going through important developmental transition phases, such as the step towards early adulthood.

  12. The development and psychometric properties of an informant-report form of the personality inventory for DSM-5 (PID-5).

    PubMed

    Markon, Kristian E; Quilty, Lena C; Bagby, R Michael; Krueger, Robert F

    2013-06-01

    The current article reports on the development, psychometric properties, and external validity of an informant-report form of the Personality Inventory for DSM-5 (the PID-5-IRF). Using data from two nationally representative samples, as well as an elevated-risk community sample, we report on the PID-5-IRF item characteristics, scale properties, superordinate factor structure, and correlations with other measures. The PID-5-IRF replicates the factor structure of the self-report form and has relationships with other measures (including the PID-5 self-report form and a widely used Big Five measure) that are consistent with previous research and theory. We believe that the PID-5-IRF is a useful measure for a number of scenarios, such as when additional sources of information are desired, where informant measures are expected to provide incremental validity over self-report, where relationships or social perception is a focal interest, or when response bias is a salient concern. Areas for future research are also discussed.

  13. Strong-coupling phases of the spin-orbit-coupled spin-1 Bose-Hubbard chain: Odd-integer Mott lobes and helical magnetic phases

    NASA Astrophysics Data System (ADS)

    Pixley, J. H.; Cole, William S.; Spielman, I. B.; Rizzi, Matteo; Das Sarma, S.

    2017-10-01

    We study the odd-integer filled Mott phases of a spin-1 Bose-Hubbard chain and determine their fate in the presence of a Raman induced spin-orbit coupling which has been achieved in ultracold atomic gases; this system is described by a quantum spin-1 chain with a spiral magnetic field. The spiral magnetic field initially induces helical order with either ferromagnetic or dimer order parameters, giving rise to a spiral paramagnet at large field. The spiral ferromagnet-to-paramagnet phase transition is in a universality class with critical exponents associated with the divergence of the correlation length ν ≈2 /3 and the order-parameter susceptibility γ ≈1 /2 . We solve the effective spin model exactly using the density-matrix renormalization group, and compare with both a large-S classical solution and a phenomenological Landau theory. We discuss how these exotic bosonic magnetic phases can be produced and probed in ultracold atomic experiments in optical lattices.

  14. A supplier selection and order allocation problem with stochastic demands

    NASA Astrophysics Data System (ADS)

    Zhou, Yun; Zhao, Lei; Zhao, Xiaobo; Jiang, Jianhua

    2011-08-01

    We consider a system comprising a retailer and a set of candidate suppliers that operates within a finite planning horizon of multiple periods. The retailer replenishes its inventory from the suppliers and satisfies stochastic customer demands. At the beginning of each period, the retailer makes decisions on the replenishment quantity, supplier selection and order allocation among the selected suppliers. An optimisation problem is formulated to minimise the total expected system cost, which includes an outer level stochastic dynamic program for the optimal replenishment quantity and an inner level integer program for supplier selection and order allocation with a given replenishment quantity. For the inner level subproblem, we develop a polynomial algorithm to obtain optimal decisions. For the outer level subproblem, we propose an efficient heuristic for the system with integer-valued inventory, based on the structural properties of the system with real-valued inventory. We investigate the efficiency of the proposed solution approach, as well as the impact of parameters on the optimal replenishment decision with numerical experiments.

  15. The checkpoint ordering problem

    PubMed Central

    Hungerländer, P.

    2017-01-01

    Abstract We suggest a new variant of a row layout problem: Find an ordering of n departments with given lengths such that the total weighted sum of their distances to a given checkpoint is minimized. The Checkpoint Ordering Problem (COP) is both of theoretical and practical interest. It has several applications and is conceptually related to some well-studied combinatorial optimization problems, namely the Single-Row Facility Layout Problem, the Linear Ordering Problem and a variant of parallel machine scheduling. In this paper we study the complexity of the (COP) and its special cases. The general version of the (COP) with an arbitrary but fixed number of checkpoints is NP-hard in the weak sense. We propose both a dynamic programming algorithm and an integer linear programming approach for the (COP) . Our computational experiments indicate that the (COP) is hard to solve in practice. While the run time of the dynamic programming algorithm strongly depends on the length of the departments, the integer linear programming approach is able to solve instances with up to 25 departments to optimality. PMID:29170574

  16. Women's sexual and reproductive health in post-socialist Georgia: does internal displacement matter?

    PubMed

    Doliashvili, Khatuna; Buckley, Cynthia J

    2008-03-01

    Persons displaced by armed conflicts, natural disasters or other events are at increased risk for health problems. The Republic of Georgia has a substantial population of internally displaced women who may face elevated risks of STIs and pelvic inflammatory disease (PID). The 1999 Georgia Reproductive Health Survey was used to examine the prevalence of self-reported STI and PID diagnoses among displaced and nondisplaced sexually experienced women. Multivariate analyses were conducted to determine whether displacement is associated with STI and PID risk, and whether the behavioral and socioeconomic factors associated with these diagnoses differ between internally displaced women and the general population. In models that controlled for behavioral factors only, displacement was associated with elevated odds of PID diagnosis (odds ratio, 1.3), but the relationship was only marginally significant when socioeconomic factors were added (1.3). Displacement was not associated with STI diagnosis. The factors associated with STI and PID diagnoses among displaced women generally differed from those in the general population, but access to medical care and previous STI diagnosis were associated with PID diagnosis in both groups. Among nondisplaced women, residing in the capital city was associated with increased odds of STI diagnosis (2.2) but reduced odds of PID diagnosis (0.8). These findings highlight the importance of displacement status in determining a woman's reproductive health risks, and underscore the complex relationships between behavioral and socioeconomic variables and the elevation of STI and PID risk.

  17. PIDs, Types and the Semantic Web

    NASA Astrophysics Data System (ADS)

    Schwardmann, Ulrich

    2017-04-01

    PID Information Types are becoming a crucial role in scientific data management because they can provide state (what) and binding (where) information about digital objects as attributes of the PID. This is a similar but much more flexible approach than the well known mime type characterization, because both of these types concepts allow to decide about preconditions for processes in advance and before touching the data. One aspect of this is the need for standards and correctness of the used types to ensure reliability for the processes operating on the digital objects. This requires registries and schemas for PID InfoTypes and suggests an automated schema generation process. Such a process in combination with data type registries will be described in more detail in the intended talk. Another aspect of PID InfoTypes is its intrinsic grammar as subject-predicate-object triple, with the PID as subject, the type as predicate and its value (often again a PID) as object in this relation. Given the registration of types and the proposed syntactical rigidness of the value, guaranteed by the schema, together with the use of PIDs in subject and predicate, the type concept has the ability to overcome the fuzziness and lack of reliability of semantic web categories with its URL references and possibly changing locations and content. The intended talk will also describe this approach in more detail, discusses the differences to linked data and describes some necessary technological developments for the type concept to keep up with the possibilities currently provided by the semantic web.

  18. Comparative study of a learning fuzzy PID controller and a self-tuning controller.

    PubMed

    Kazemian, H B

    2001-01-01

    The self-organising fuzzy controller is an extension of the rule-based fuzzy controller with an additional learning capability. The self-organising fuzzy (SOF) is used as a master controller to readjust conventional PID gains at the actuator level during the system operation, copying the experience of a human operator. The application of the self-organising fuzzy PID (SOF-PID) controller to a 2-link non-linear revolute-joint robot-arm is studied using path tracking trajectories at the setpoint. For the purpose of comparison, the same experiments are repeated by using the self-tuning controller subject to the same data supplied at the setpoint. For the path tracking experiments, the output trajectories of the SOF-PID controller followed the specified path closer and smoother than the self-tuning controller.

  19. Perturbation of Auxin Homeostasis and Signaling by PINOID Overexpression Induces Stress Responses in Arabidopsis

    PubMed Central

    Saini, Kumud; AbdElgawad, Hamada; Markakis, Marios N.; Schoenaers, Sébastjen; Asard, Han; Prinsen, Els; Beemster, Gerrit T. S.; Vissenberg, Kris

    2017-01-01

    Under normal and stress conditions plant growth require a complex interplay between phytohormones and reactive oxygen species (ROS). However, details of the nature of this crosstalk remain elusive. Here, we demonstrate that PINOID (PID), a serine threonine kinase of the AGC kinase family, perturbs auxin homeostasis, which in turn modulates rosette growth and induces stress responses in Arabidopsis plants. Arabidopsis mutants and transgenic plants with altered PID expression were used to study the effect on auxin levels and stress-related responses. In the leaves of plants with ectopic PID expression an accumulation of auxin, oxidative burst and disruption of hormonal balance was apparent. Furthermore, PID overexpression led to the accumulation of antioxidant metabolites, while pid knockout mutants showed only moderate changes in stress-related metabolites. These physiological changes in the plants overexpressing PID modulated their response toward external drought and osmotic stress treatments when compared to the wild type. Based on the morphological, transcriptome, and metabolite results, we propose that perturbations in the auxin hormone levels caused by PID overexpression, along with other hormones and ROS downstream, cause antioxidant accumulation and modify growth and stress responses in Arabidopsis. Our data provide further proof for a strong correlation between auxin and stress biology. PMID:28824662

  20. Risk factors for laparoscopically confirmed pelvic inflammatory disease: findings from Mumbai (Bombay), India.

    PubMed

    Gogate, A; Brabin, L; Nicholas, S; Gogate, S; Gaonkar, T; Naidu, A; Divekar, A; Karande, A; Hart, C A

    1998-12-01

    Sexually transmitted diseases (STDs) are an important cause of pelvic inflammatory disease (PID) but have often not been detected in microbiological studies of Indian women admitted to hospital gynaecology wards or private clinics. In this cross sectional study, women living in the inner city of Mumbai (Bombay) were investigated for socioeconomic, clinical, and microbiological risk factors for PID. Microbiological tests and laparoscopic examination were carried out on 2736 women aged < or = 35 years who came to a health facility with suspected acute salpingitis or infertility or for laparoscopic sterilisation. 86 women with a clinical diagnosis of PID were not referred for laparoscopy although their characteristics are described. Associations between various risk factors and PID status were investigated and logistic regression performed on all factors that remained significant. Of women with a laparoscopically confirmed evaluation, 26 women had acute and 48 chronic pelvic infection. Independent risk factors for PID were later age at menarche (> or = 14 years), a history of stillbirth and no previous pregnancy, history of tuberculosis, STD, dilatation and curettage or previous laparoscopy, and presence of Gardnerella vaginalis. It is concluded that STD related risk factors applied to only a small proportion of PID cases and that other determinants of PID are important, including obstetric complications, invasive surgical procedures such as laparoscopy, and tuberculosis.

  1. Data-Driven Based Asynchronous Motor Control for Printing Servo Systems

    NASA Astrophysics Data System (ADS)

    Bian, Min; Guo, Qingyun

    Modern digital printing equipment aims to the environmental-friendly industry with high dynamic performances and control precision and low vibration and abrasion. High performance motion control system of printing servo systems was required. Control system of asynchronous motor based on data acquisition was proposed. Iterative learning control (ILC) algorithm was studied. PID control was widely used in the motion control. However, it was sensitive to the disturbances and model parameters variation. The ILC applied the history error data and present control signals to approximate the control signal directly in order to fully track the expect trajectory without the system models and structures. The motor control algorithm based on the ILC and PID was constructed and simulation results were given. The results show that data-driven control method is effective dealing with bounded disturbances for the motion control of printing servo systems.

  2. Smith predictor based-sliding mode controller for integrating processes with elevated deadtime.

    PubMed

    Camacho, Oscar; De la Cruz, Francisco

    2004-04-01

    An approach to control integrating processes with elevated deadtime using a Smith predictor sliding mode controller is presented. A PID sliding surface and an integrating first-order plus deadtime model have been used to synthesize the controller. Since the performance of existing controllers with a Smith predictor decrease in the presence of modeling errors, this paper presents a simple approach to combining the Smith predictor with the sliding mode concept, which is a proven, simple, and robust procedure. The proposed scheme has a set of tuning equations as a function of the characteristic parameters of the model. For implementation of our proposed approach, computer based industrial controllers that execute PID algorithms can be used. The performance and robustness of the proposed controller are compared with the Matausek-Micić scheme for linear systems using simulations.

  3. The European internet-based patient and research database for primary immunodeficiencies: update 2011

    PubMed Central

    Gathmann, B; Binder, N; Ehl, S; Kindle, G

    2012-01-01

    In order to build a common data pool and estimate the disease burden of primary immunodeficiencies (PID) in Europe, the European Society for Immunodeficiencies (ESID) has developed an internet-based database for clinical and research data on patients with PID. This database is a platform for epidemiological analyses as well as the development of new diagnostic and therapeutic strategies and the identification of novel disease-associated genes. Since its start in 2004, 13 708 patients from 41 countries have been documented in the ESID database. Common variable immunodeficiency (CVID) represents the most common entity with 2880 patients or 21% of all entries, followed by selective immunoglobulin A (sIgA) deficiency (1424 patients, 10·4%). The total documented prevalence of PID is highest in France, with five patients per 100 000 inhabitants. The highest documented prevalence for a single disease is 1·3 per 100 000 inhabitants for sIgA deficiency in Hungary. The highest reported incidence of PID per 100 000 live births was 16·2 for the period 1999–2002 in France. The highest reported incidence rate for a single disease was 6·7 for sIgA deficiency in Spain for the period 1999–2002. The genetic cause was known in 36·2% of all registered patients. Consanguinity was reported in 8·8%, and 18·5% of patients were reported to be familial cases; 27·9% of patients were diagnosed after the age of 16. We did not observe a significant decrease in the diagnostic delay for most diseases between 1987 and 2010. The most frequently reported long-term medication is immunoglobulin replacement. PMID:22288591

  4. Fast scaffolding with small independent mixed integer programs

    PubMed Central

    Salmela, Leena; Mäkinen, Veli; Välimäki, Niko; Ylinen, Johannes; Ukkonen, Esko

    2011-01-01

    Motivation: Assembling genomes from short read data has become increasingly popular, but the problem remains computationally challenging especially for larger genomes. We study the scaffolding phase of sequence assembly where preassembled contigs are ordered based on mate pair data. Results: We present MIP Scaffolder that divides the scaffolding problem into smaller subproblems and solves these with mixed integer programming. The scaffolding problem can be represented as a graph and the biconnected components of this graph can be solved independently. We present a technique for restricting the size of these subproblems so that they can be solved accurately with mixed integer programming. We compare MIP Scaffolder to two state of the art methods, SOPRA and SSPACE. MIP Scaffolder is fast and produces better or as good scaffolds as its competitors on large genomes. Availability: The source code of MIP Scaffolder is freely available at http://www.cs.helsinki.fi/u/lmsalmel/mip-scaffolder/. Contact: leena.salmela@cs.helsinki.fi PMID:21998153

  5. Multi-task feature selection in microarray data by binary integer programming.

    PubMed

    Lan, Liang; Vucetic, Slobodan

    2013-12-20

    A major challenge in microarray classification is that the number of features is typically orders of magnitude larger than the number of examples. In this paper, we propose a novel feature filter algorithm to select the feature subset with maximal discriminative power and minimal redundancy by solving a quadratic objective function with binary integer constraints. To improve the computational efficiency, the binary integer constraints are relaxed and a low-rank approximation to the quadratic term is applied. The proposed feature selection algorithm was extended to solve multi-task microarray classification problems. We compared the single-task version of the proposed feature selection algorithm with 9 existing feature selection methods on 4 benchmark microarray data sets. The empirical results show that the proposed method achieved the most accurate predictions overall. We also evaluated the multi-task version of the proposed algorithm on 8 multi-task microarray datasets. The multi-task feature selection algorithm resulted in significantly higher accuracy than when using the single-task feature selection methods.

  6. On the Structure of Personality Disorder Traits: Conjoint Analyses of the CAT-PD, PID-5, and NEO-PI-3 Trait Models

    PubMed Central

    Wright, Aidan G.C.; Simms, Leonard J.

    2014-01-01

    The current study examines the relations among contemporary models of pathological and normal range personality traits. Specifically, we report on (a) conjoint exploratory factor analyses of the Computerized Adaptive Test of Personality Disorder static form (CAT-PD-SF) with the Personality Inventory for the DSM-5 (PID-5; Krueger et al., 2012) and NEO Personality Inventory-3 First Half (NEI-PI-3FH; McCrae & Costa, 2007), and (b) unfolding hierarchical analyses of the three measures in a large general psychiatric outpatient sample (N = 628; 64% Female). A five-factor solution provided conceptually coherent alignment among the CAT-PD-SF, PID-5, and NEO-PI-3FH scales. Hierarchical solutions suggested that higher-order factors bear strong resemblance to dimensions that emerge from structural models of psychopathology (e.g., Internalizing and Externalizing spectra). These results demonstrate that the CAT-PD-SF adheres to the consensual structure of broad trait domains at the five-factor level. Additionally, patterns of scale loadings further inform questions of structure and bipolarity of facet and domain level constructs. Finally, hierarchical analyses strengthen the argument for using broad dimensions that span normative and pathological functioning to scaffold a quantitatively derived phenotypic structure of psychopathology to orient future research on explanatory, etiological, and maintenance mechanisms. PMID:24588061

  7. Alterations in Red Blood Cell Functionality Induced by an Indole Scaffold Containing a Y-Iminodiketo Moiety: Potential Antiproliferative Conditions

    PubMed Central

    Scala, Angela; Ficarra, Silvana; Russo, Annamaria; Giunta, Elena; Galtieri, Antonio; Tellone, Ester

    2016-01-01

    We have recently proposed a new erythrocyte-based model of study to predict the antiproliferative effects of selected heterocyclic scaffolds. Starting from the metabolic similarity between erythrocytes and cancer cells, we have demonstrated how the metabolic derangement induced by an indolone-based compound (DPIT) could be related to its antiproliferative effects. In order to prove the validity of our biochemical approach, in the present study the effects on erythrocyte functionality of its chemical precursor (PID), whose synthesis we reported, were investigated. The influence of the tested compound on band 3 protein (B3), oxidative state, ATP efflux, caspase 3, metabolism, intracellular pH, and Ca2+ homeostasis has been evaluated. PID crosses the membrane localizing into the cytosol, increases anion exchange, induces direct caspase activation, shifts the erythrocytes towards an oxidative state, and releases less ATP than in normal conditions. Analysis of phosphatidylserine externalization shows that PID slightly induces apoptosis. Our findings indicate that, due to its unique features, erythrocyte responses to exogenous molecular stimuli can be fruitfully correlated at structurally more complex cells, such as cancer cells. Overall, our work indicates that erythrocyte is a powerful study tool to elucidate the biochemical/biological effects of selected heterocycles opening considerable perspectives in the field of drug discovery. PMID:27651854

  8. Health technology assessment review: Computerized glucose regulation in the intensive care unit - how to create artificial control

    PubMed Central

    2009-01-01

    Current care guidelines recommend glucose control (GC) in critically ill patients. To achieve GC, many ICUs have implemented a (nurse-based) protocol on paper. However, such protocols are often complex, time-consuming, and can cause iatrogenic hypoglycemia. Computerized glucose regulation protocols may improve patient safety, efficiency, and nurse compliance. Such computerized clinical decision support systems (Cuss) use more complex logic to provide an insulin infusion rate based on previous blood glucose levels and other parameters. A computerized CDSS for glucose control has the potential to reduce overall workload, reduce the chance of human cognitive failure, and improve glucose control. Several computer-assisted glucose regulation programs have been published recently. In order of increasing complexity, the three main types of algorithms used are computerized flowcharts, Proportional-Integral-Derivative (PID), and Model Predictive Control (MPC). PID is essentially a closed-loop feedback system, whereas MPC models the behavior of glucose and insulin in ICU patients. Although the best approach has not yet been determined, it should be noted that PID controllers are generally thought to be more robust than MPC systems. The computerized Cuss that are most likely to emerge are those that are fully a part of the routine workflow, use patient-specific characteristics and apply variable sampling intervals. PMID:19849827

  9. Persistent identifiers for CMIP6 data in the Earth System Grid Federation

    NASA Astrophysics Data System (ADS)

    Buurman, Merret; Weigel, Tobias; Juckes, Martin; Lautenschlager, Michael; Kindermann, Stephan

    2016-04-01

    The Earth System Grid Federation (ESGF) is a distributed data infrastructure that will provide access to the CMIP6 experiment data. The data consist of thousands of datasets composed of millions of files. Over the course of the CMIP6 operational phase, datasets may be retracted and replaced by newer versions that consist of completely or partly new files. Each dataset is hosted at a single data centre, but can have one or several backups (replicas) at other data centres. To keep track of the different data entities and relationships between them, to ensure their consistency and improve exchange of information about them, Persistent Identifiers (PIDs) are used. These are unique identifiers that are registered at a globally accessible server, along with some metadata (the PID record). While usually providing access to the data object they refer to, as long as it exists, the metadata record will remain available even beyond the object's lifetime. Besides providing access to data and metadata, PIDs will allow scientists to communicate effectively and on a fine granularity about CMIP6 data. The initiative to introduce PIDs in the ESGF infrastructure has been described and agreed upon through a series of white papers governed by the WGCM Infrastructure Panel (WIP). In CMIP6, each dataset and each file is assigned a PID that keeps track of the data object's physical copies throughout the object lifetime. In addition to this, its relationship with other data objects is stored in the PID recordA human-readable version of this information is available on an information page also linked in the PID record. A possible application that exploits the information available from the PID records is a smart information tool, which a scientific user can call to find out if his/her version was replaced by a new one, to view and browse the related datasets and files, and to get access to the various copies or to additional metadata on a dedicated website. The PID registration process is embedded in the ESGF data publication process. During their first publication, the PID records are populated with metadata including the parent dataset(s), other existing versions and physical location. Every subsequent publication, un-publication or replica publication of a dataset or file then updates the PID records to keep track of changing physical locations of the data (or lack thereof) and of reported errors in the data. Assembling the metadata records and registering the PIDs on a central server is a potential performance bottleneck as millions of data objects may be published in a short timeframe when the CMIP6 experiment phase begins. For this reason, the PID registration and metadata update tasks are pushed to a message queueing system facilitating high availability and scalability and then processed asynchronously. This will lead to a slight delay in PID registration but will avoid blocking resources at the data centres and slowing down the publication of the data so eagerly awaited by the scientists.

  10. Numerical analysis for the fractional diffusion and fractional Buckmaster equation by the two-step Laplace Adam-Bashforth method

    NASA Astrophysics Data System (ADS)

    Jain, Sonal

    2018-01-01

    In this paper, we aim to use the alternative numerical scheme given by Gnitchogna and Atangana for solving partial differential equations with integer and non-integer differential operators. We applied this method to fractional diffusion model and fractional Buckmaster models with non-local fading memory. The method yields a powerful numerical algorithm for fractional order derivative to implement. Also we present in detail the stability analysis of the numerical method for solving the diffusion equation. This proof shows that this method is very stable and also converges very quickly to exact solution and finally some numerical simulation is presented.

  11. Comparison of penalty functions on a penalty approach to mixed-integer optimization

    NASA Astrophysics Data System (ADS)

    Francisco, Rogério B.; Costa, M. Fernanda P.; Rocha, Ana Maria A. C.; Fernandes, Edite M. G. P.

    2016-06-01

    In this paper, we present a comparative study involving several penalty functions that can be used in a penalty approach for globally solving bound mixed-integer nonlinear programming (bMIMLP) problems. The penalty approach relies on a continuous reformulation of the bMINLP problem by adding a particular penalty term to the objective function. A penalty function based on the `erf' function is proposed. The continuous nonlinear optimization problems are sequentially solved by the population-based firefly algorithm. Preliminary numerical experiments are carried out in order to analyze the quality of the produced solutions, when compared with other penalty functions available in the literature.

  12. Finite-time stabilisation of a class of switched nonlinear systems with state constraints

    NASA Astrophysics Data System (ADS)

    Huang, Shipei; Xiang, Zhengrong

    2018-06-01

    This paper investigates the finite-time stabilisation for a class of switched nonlinear systems with state constraints. Some power orders of the system are allowed to be ratios of positive even integers over odd integers. A Barrier Lyapunov function is introduced to guarantee that the state constraint is not violated at any time. Using the convex combination method and a recursive design approach, a state-dependent switching law and state feedback controllers of individual subsystems are constructed such that the closed-loop system is finite-time stable without violation of the state constraint. Two examples are provided to show the effectiveness of the proposed method.

  13. Primary Immunodeficiency Diseases in Aguascalientes, Mexico: Results from an Educational Program.

    PubMed

    Alvarez-Cardona, Aristoteles; Espinosa-Padilla, Sara Elva; Reyes, Saul Oswaldo Lugo; Ventura-Juarez, Javier; Lopez-Valdez, Jaime Asael; Martínez-Medina, Lucila; Santillan-Artolozaga, Alberto; Cajero-Avelar, Adriana; De Luna-Sosa, Alma R; Torres-Bernal, Luis F; Espinosa-Rosales, Francisco J

    2016-04-01

    Primary immunodeficiencies (PIDs) are a heterogeneous group of disorders characterized mainly by recurrent infections. Late diagnosis remains as one of the main issues to solve. We aimed to increase PID diagnosis in Aguascalientes, a 1.3 million inhabitants state in the center of Mexico, and to describe the clinical features of such patients. We developed an educational program for health personnel and general public; patients with possible PID were referred to a State University clinical center from December 2011 to December 2012. The patients were evaluated at the clinic and their definitive diagnosis pursued through laboratory, molecular and genetic assays. We describe the findings of those patients and analyze the impact of the program in terms of number of referrals. After 41 talks and 12 media appearances 151 patients were referred for evaluation. Fifteen (9.9%) were diagnosed with PID: five (33%) had antibody deficiencies, seven (47%) Well-defined syndromes, two (13%) Severe combined Immunodeficiency (SCID) and one case (7%) of an innate immune deficiency. All of the 15 PID patients had been referred by physicians, as opposed to the public. We estimated a "number needed to teach" of 75 physicians to get one PID patient referral. Educational programs are a fundamental part of the global efforts to increase PID diagnosis and care. To be successful, such programs should include public relations, reach for first-contact physicians, and aim to develop an efficient referral network with molecular diagnostic capability. Enhancing medical knowledge on PID is a successful strategy to improve early diagnosis and treatment.

  14. Doctors' awareness concerning primary immunodeficiencies in Brazil.

    PubMed

    Dantas, E O; Aranda, C S; Rêgo Silva, A M; Tavares, F S; Severo Ferreira, J F; de Quadros Coelho, M A; de Siqueira Kovalhuk, L C; Roxo Júnior, P; Toledo, E C; Porto Neto, A C; de Sousa Vieira, H M C; Takano, O A; Nobre, F A; Sano, F; Nudelman, V; de Farias Sales, V S; Silva Segundo, G R; Villar Guedes, H T; Félix, E; Marques, S M B; Mazzucchelli, J T L; Wandalsen, N F; Pinto, J A; Paes Barreto, I C D; Silva, M R; Rullo, V E V; Franco, J M; Damasceno, E; Fahl, K; de Moraes-Pinto, M I; Del Nero, D L; Moraes, L S L; Condino-Neto, A; Vilela, M M; Góes, H; Schisler, K L; Miranda, E; Goudouris, E S; Costa Carvalho, B T

    2015-01-01

    PIDs are a heterogeneous group of genetic illnesses, and delay in their diagnosis is thought to be caused by a lack of awareness among physicians concerning PIDs. The latter is what we aimed to evaluate in Brazil. Physicians working at general hospitals all over the country were asked to complete a 14-item questionnaire. One of the questions described 25 clinical situations that could be associated with PIDs and a score was created based on percentages of appropriate answers. A total of 4026 physicians participated in the study: 1628 paediatricians (40.4%), 1436 clinicians (35.7%), and 962 surgeons (23.9%). About 67% of the physicians had learned about PIDs in medical school or residency training, 84.6% evaluated patients who frequently took antibiotics, but only 40.3% of them participated in the immunological evaluation of these patients. Seventy-seven percent of the participating physicians were not familiar with the warning signs for PIDs. The mean score of correct answers for the 25 clinical situations was 48.08% (±16.06). Only 18.3% of the paediatricians, 7.4% of the clinicians, and 5.8% of the surgeons answered at least 2/3 of these situations appropriately. There is a lack of medical awareness concerning PIDs, even among paediatricians, who have been targeted with PID educational programmes in recent years in Brazil. An increase in awareness with regard to these disorders within the medical community is an important step towards improving recognition and treatment of PIDs. Copyright © 2014 SEICAP. Published by Elsevier Espana. All rights reserved.

  15. Paradeisos: A perfect hashing algorithm for many-body eigenvalue problems

    NASA Astrophysics Data System (ADS)

    Jia, C. J.; Wang, Y.; Mendl, C. B.; Moritz, B.; Devereaux, T. P.

    2018-03-01

    We describe an essentially perfect hashing algorithm for calculating the position of an element in an ordered list, appropriate for the construction and manipulation of many-body Hamiltonian, sparse matrices. Each element of the list corresponds to an integer value whose binary representation reflects the occupation of single-particle basis states for each element in the many-body Hilbert space. The algorithm replaces conventional methods, such as binary search, for locating the elements of the ordered list, eliminating the need to store the integer representation for each element, without increasing the computational complexity. Combined with the "checkerboard" decomposition of the Hamiltonian matrix for distribution over parallel computing environments, this leads to a substantial savings in aggregate memory. While the algorithm can be applied broadly to many-body, correlated problems, we demonstrate its utility in reducing total memory consumption for a series of fermionic single-band Hubbard model calculations on small clusters with progressively larger Hilbert space dimension.

  16. New Approaches to Minimum-Energy Design of Integer- and Fractional-Order Perfect Control Algorithms

    NASA Astrophysics Data System (ADS)

    Hunek, Wojciech P.; Wach, Łukasz

    2017-10-01

    In this paper the new methods concerning the energy-based minimization of the perfect control inputs is presented. For that reason the multivariable integer- and fractional-order models are applied which can be used for describing a various real world processes. Up to now, the classical approaches have been used in forms of minimum-norm/least squares inverses. Notwithstanding, the above-mentioned tool do not guarantee the optimal control corresponding to optimal input energy. Therefore the new class of inversebased methods has been introduced, in particular the new σ- and H-inverse of nonsquare parameter and polynomial matrices. Thus a proposed solution remarkably outperforms the typical ones in systems where the control runs can be understood in terms of different physical quantities, for example heat and mass transfer, electricity etc. A simulation study performed in Matlab/Simulink environment confirms the big potential of the new energy-based approaches.

  17. Fractional viscoelasticity in fractal and non-fractal media: Theory, experimental validation, and uncertainty analysis

    NASA Astrophysics Data System (ADS)

    Mashayekhi, Somayeh; Miles, Paul; Hussaini, M. Yousuff; Oates, William S.

    2018-02-01

    In this paper, fractional and non-fractional viscoelastic models for elastomeric materials are derived and analyzed in comparison to experimental results. The viscoelastic models are derived by expanding thermodynamic balance equations for both fractal and non-fractal media. The order of the fractional time derivative is shown to strongly affect the accuracy of the viscoelastic constitutive predictions. Model validation uses experimental data describing viscoelasticity of the dielectric elastomer Very High Bond (VHB) 4910. Since these materials are known for their broad applications in smart structures, it is important to characterize and accurately predict their behavior across a large range of time scales. Whereas integer order viscoelastic models can yield reasonable agreement with data, the model parameters often lack robustness in prediction at different deformation rates. Alternatively, fractional order models of viscoelasticity provide an alternative framework to more accurately quantify complex rate-dependent behavior. Prior research that has considered fractional order viscoelasticity lacks experimental validation and contains limited links between viscoelastic theory and fractional order derivatives. To address these issues, we use fractional order operators to experimentally validate fractional and non-fractional viscoelastic models in elastomeric solids using Bayesian uncertainty quantification. The fractional order model is found to be advantageous as predictions are significantly more accurate than integer order viscoelastic models for deformation rates spanning four orders of magnitude.

  18. Adoptive T Cell Immunotherapy for Patients with Primary Immunodeficiency Disorders.

    PubMed

    McLaughlin, Lauren P; Bollard, Catherine M; Keller, Michael

    2017-01-01

    Primary immunodeficiency disorders (PID) are a group of inborn errors of immunity with a broad range of clinical severity but often associated with recurrent and serious infections. While hematopoietic stem cell transplantation (HSCT) can be curative for some forms of PID, chronic and/or refractory viral infections remain a cause of morbidity and mortality both before and after HSCT. Although antiviral pharmacologic agents exist for many viral pathogens, these are associated with significant costs and toxicities and may not be effective for increasingly drug-resistant pathogens. Thus, the emergence of adoptive immunotherapy with virus-specific T lymphocytes (VSTs) is an attractive option for addressing the underlying impaired T cell immunity in many PID patients. VSTs have been utilized for PID patients following HSCT in many prior phase I trials, and may potentially be beneficial before HSCT in patients with chronic viral infections. We review the various methods of generating VSTs, clinical experience using VSTs for PID patients, and current limitations as well as potential ways to broaden the clinical applicability of adoptive immunotherapy for PID patients.

  19. Primary Immune Deficiencies – Principles of Care

    PubMed Central

    Chapel, Helen; Prevot, Johan; Gaspar, Hubert Bobby; Español, Teresa; Bonilla, Francisco A.; Solis, Leire; Drabwell, Josina

    2014-01-01

    Primary immune deficiencies (PIDs) are a growing group of over 230 different disorders caused by ineffective, absent or an increasing number of gain of function mutations in immune components, mainly cells and proteins. Once recognized, these rare disorders are treatable and in some cases curable. Otherwise untreated PIDs are often chronic, serious, or even fatal. The diagnosis of PIDs can be difficult due to lack of awareness or facilities for diagnosis, and management of PIDs is complex. This document was prepared by a worldwide multi-disciplinary team of specialists; it aims to set out comprehensive principles of care for PIDs. These include the role of specialized centers, the importance of registries, the need for multinational research, the role of patient organizations, management and treatment options, the requirement for sustained access to all treatments including immunoglobulin therapies and hematopoietic stem cell transplantation, important considerations for developing countries and suggestions for implementation. A range of healthcare policies and services have to be put into place by government agencies and healthcare providers, to ensure that PID patients worldwide have access to appropriate and sustainable medical and support services. PMID:25566243

  20. Novel bio-inspired smart control for hazard mitigation of civil structures

    NASA Astrophysics Data System (ADS)

    Kim, Yeesock; Kim, Changwon; Langari, Reza

    2010-11-01

    In this paper, a new bio-inspired controller is proposed for vibration mitigation of smart structures subjected to ground disturbances (i.e. earthquakes). The control system is developed through the integration of a brain emotional learning (BEL) algorithm with a proportional-integral-derivative (PID) controller and a semiactive inversion (Inv) algorithm. The BEL algorithm is based on the neurologically inspired computational model of the amygdala and the orbitofrontal cortex. To demonstrate the effectiveness of the proposed hybrid BEL-PID-Inv control algorithm, a seismically excited building structure equipped with a magnetorheological (MR) damper is investigated. The performance of the proposed hybrid BEL-PID-Inv control algorithm is compared with that of passive, PID, linear quadratic Gaussian (LQG), and BEL control systems. In the simulation, the robustness of the hybrid BEL-PID-Inv control algorithm in the presence of modeling uncertainties as well as external disturbances is investigated. It is shown that the proposed hybrid BEL-PID-Inv control algorithm is effective in improving the dynamic responses of seismically excited building structure-MR damper systems.

  1. Fault tolerant control of multivariable processes using auto-tuning PID controller.

    PubMed

    Yu, Ding-Li; Chang, T K; Yu, Ding-Wen

    2005-02-01

    Fault tolerant control of dynamic processes is investigated in this paper using an auto-tuning PID controller. A fault tolerant control scheme is proposed composing an auto-tuning PID controller based on an adaptive neural network model. The model is trained online using the extended Kalman filter (EKF) algorithm to learn system post-fault dynamics. Based on this model, the PID controller adjusts its parameters to compensate the effects of the faults, so that the control performance is recovered from degradation. The auto-tuning algorithm for the PID controller is derived with the Lyapunov method and therefore, the model predicted tracking error is guaranteed to converge asymptotically. The method is applied to a simulated two-input two-output continuous stirred tank reactor (CSTR) with various faults, which demonstrate the applicability of the developed scheme to industrial processes.

  2. Skin signs of primary immunodeficiencies: how to find the genes to check.

    PubMed

    Ettinger, M; Schreml, J; Wirsching, K; Berneburg, M; Schreml, S

    2018-02-01

    Primary immunodeficiencies (PIDs) are a heterogeneous group of rare diseases that result from defects in immune system development and/or function. The clinical manifestations of PIDs are highly variable, but most disorders involve at least an increased susceptibility to infection. Furthermore, cutaneous manifestations are very common in PIDs. As an easily accessible organ, the skin can be crucial for early diagnosis and treatment. This is relevant for preventing significant disease-associated morbidity and mortality. We provide a table that enables the reader to find the possible diseases and corresponding gene defects based on the skin manifestations of the suspected PIDs. To our knowledge, this is the first review that allows the reader to find relevant PIDs and the respective gene defects through solitary or combined skin signs. © 2017 British Association of Dermatologists.

  3. Method study on fuzzy-PID adaptive control of electric-hydraulic hitch system

    NASA Astrophysics Data System (ADS)

    Li, Mingsheng; Wang, Liubu; Liu, Jian; Ye, Jin

    2017-03-01

    In this paper, fuzzy-PID adaptive control method is applied to the control of tractor electric-hydraulic hitch system. According to the characteristics of the system, a fuzzy-PID adaptive controller is designed and the electric-hydraulic hitch system model is established. Traction control and position control performance simulation are carried out with the common PID control method. A field test rig was set up to test the electric-hydraulic hitch system. The test results showed that, after the fuzzy-PID adaptive control is adopted, when the tillage depth steps from 0.1m to 0.3m, the system transition process time is 4s, without overshoot, and when the tractive force steps from 3000N to 7000N, the system transition process time is 5s, the system overshoot is 25%.

  4. On the origins of generalized fractional calculus

    NASA Astrophysics Data System (ADS)

    Kiryakova, Virginia

    2015-11-01

    In Fractional Calculus (FC), as in the (classical) Calculus, the notions of derivatives and integrals (of first, second, etc. or arbitrary, incl. non-integer order) are basic and co-related. One of the most frequent approach in FC is to define first the Riemann-Liouville (R-L) integral of fractional order, and then by means of suitable integer-order differentiation operation applied over it (or under its sign) a fractional derivative is defined - in the R-L sense (or in Caputo sense). The first mentioned (R-L type) is closer to the theoretical studies in analysis, but has some shortages - from the point of view of interpretation of the initial conditions for Cauchy problems for fractional differential equations (stated also by means of fractional order derivatives/ integrals), and also for the analysts' confusion that such a derivative of a constant is not zero in general. The Caputo (C-) derivative, arising first in geophysical studies, helps to overcome these problems and to describe models of applied problems with physically consistent initial conditions. The operators of the Generalized Fractional Calculus - GFC (integrals and derivatives) are based on commuting m-tuple (m = 1, 2, 3, …) compositions of operators of the classical FC with power weights (the so-called Erdélyi-Kober operators), but represented in compact and explicit form by means of integral, integro-differential (R-L type) or differential-integral (C-type) operators, where the kernels are special functions of most general hypergeometric kind. The foundations of this theory are given in Kiryakova 18. In this survey we present the genesis of the definitions of the GFC - the generalized fractional integrals and derivatives (of fractional multi-order) of R-L type and Caputo type, analyze their properties and applications. Their special cases are all the known operators of classical FC, their generalizations introduced by other authors, the hyper-Bessel differential operators of higher integer order m as a multi-order (1, 1,…, 1), the Gelfond-Leontiev generalized differentiation operators, many other integral and differential operators in Calculus that have been used in various topics, some of them not related to FC at all, others involved in differential and integral equations for treating fractional order models.

  5. Host defense responses associated with experimental hemorrhagic disease in white-tailed deer.

    PubMed

    Quist, C F; Howerth, E W; Stallknecht, D E; Brown, J; Pisell, T; Nettles, V F

    1997-07-01

    Our objectives were to examine the immunity conferred by epizootic hemorrhagic disease virus serotype 2 (EHDV-2) infection in white-tailed deer (Odocoileus virginianus) and determine if this immunity was protective during challenge with homologous (EHDV-2) or heterologous (bluetongue virus serotype 10; BTV-10) virus. Trials were conducted in the fall of 1992 and 1993. In the first experiment, naive white-tailed deer were infected intradermally and subcutaneously with EHDV-2 and monitored via physical examinations, complete blood counts, alpha and beta interferon (IFN) assays, viral isolation, and serology. Infected deer had a wide range of clinical signs in response to infection. Eleven of the 16 deer had body temperature elevations > or = 0.5 C between post-infection day (PID) 4 and 8. Infected deer had decreased lymphocyte counts between PID 6 and 10 that returned to normal levels by PID 17. Severely lymphopenic animals had the most severe clinical signs; five of 10 deer with lymphocyte counts less than 1000 cells/microliters succumbed to the infection. Viremia was detected in all 16 EHDV-2 infected animals by PID 4, and peak viremias occurred between PID 4 and PID 10. Three deer remained viremic until PID 56, the study endpoint. Interferon was first detected between PID 2 and 6. Peak alpha and beta IFN levels coincided with peak viremia in 11 deer. Precipitating and neutralizing antibodies were detected in infected deer by PID 10. In the second experiment, convalescent deer were challenged subcutaneously and intradermally with either EHDV-2 or BTV-10 and similarly monitored. Virus was detected in the blood of all four deer challenged with BTV-10, but viremia was not detected in three EHDV-2-challenged deer. Temperature fluctuations, blood cell parameter changes, and IFN and antibody responses seen in BTV-10-challenged deer were similar to those seen in the initial experiment. Deer challenged with EHDV-2 had mildly increased temperatures, but minimal IFN response and lymphocyte alterations.

  6. Current perspectives in the USA on the diagnosis and treatment of pelvic inflammatory disease in adolescents.

    PubMed

    Risser, William L; Risser, Jan M; Risser, Amanda L

    2017-01-01

    In this review, the epidemiology, diagnosis, and treatment of pelvic inflammatory disease (PID) are discussed from a USA perspective and the difficulties that USA adolescents face in recognizing and seeking care for PID and other sexually transmitted infections (STIs) are emphasized. Females aged 15-24 years have the highest incidence of cervical infection with Chlamydia trachomatis and Neisseria gonorrheae , the principal causes of PID. PID is common in this age group. However, the incidence of PID in the USA is not known, because it is not a reportable disease, and because clinicians vary in the criteria used for the diagnosis. The Centers for Disease Control and Prevention (CDC) recommended the following diagnostic criteria that include lower abdominal or pelvic pain and at least one of the following: adnexal tenderness or cervical motion tenderness or uterine tenderness. Because PID can have serious sequelae, the criteria emphasize sensitivity (few false-negatives) at the expense of specificity (some false-positives). Patients who have PID are usually treated in the outpatient setting, following the CDC's Guidelines for the Treatment of Sexually Transmitted Diseases 2015. They receive one dose of an intramuscular cephalosporin, together with 2 weeks of oral doxy cycline, and sometimes oral metronidazole. Improvement should usually be evident in 3 days. The USA does not offer comprehensive sex education for adolescents in public or private schools. Adolescents are unlikely to recognize the symptoms of PID and seek medical treatment. Confidentiality is important to adolescents, and low cost or free sources of confidential care are uncommon, making it unlikely that an adolescent would seek care even if she suspected an STI. The CDC has concluded that screening programs for chlamydia and gonorrhea infection help prevent PID; however, the lack of appropriate sources of care makes adolescents' participation in screening programs unlikely.

  7. Dietary Docosahexaenoic Acid Improves Cognitive Function, Tissue Sparing, and Magnetic Resonance Imaging Indices of Edema and White Matter Injury in the Immature Rat after Traumatic Brain Injury.

    PubMed

    Schober, Michelle E; Requena, Daniela F; Abdullah, Osama M; Casper, T Charles; Beachy, Joanna; Malleske, Daniel; Pauly, James R

    2016-02-15

    Traumatic brain injury (TBI) is the leading cause of acquired neurologic disability in children. Specific therapies to treat acute TBI are lacking. Cognitive impairment from TBI may be blunted by decreasing inflammation and oxidative damage after injury. Docosahexaenoic acid (DHA) decreases cognitive impairment, oxidative stress, and white matter injury in adult rats after TBI. Effects of DHA on cognitive outcome, oxidative stress, and white matter injury in the developing rat after experimental TBI are unknown. We hypothesized that DHA would decrease early inflammatory markers and oxidative stress, and improve cognitive, imaging and histologic outcomes in rat pups after controlled cortical impact (CCI). CCI or sham surgery was delivered to 17 d old male rat pups exposed to DHA or standard diet for the duration of the experiments. DHA was introduced into the dam diet the day before CCI to allow timely DHA delivery to the pre-weanling pups. Inflammatory cytokines and nitrates/nitrites were measured in the injured brains at post-injury Day (PID) 1 and PID2. Morris water maze (MWM) testing was performed at PID41-PID47. T2-weighted and diffusion tensor imaging studies were obtained at PID12 and PID28. Tissue sparing was calculated histologically at PID3 and PID50. DHA did not adversely affect rat survival or weight gain. DHA acutely decreased oxidative stress and increased anti-inflammatory interleukin 10 in CCI brains. DHA improved MWM performance and lesion volume late after injury. At PID12, DHA decreased T2-imaging measures of cerebral edema and decreased radial diffusivity, an index of white matter injury. DHA improved short- and long-term neurologic outcomes after CCI in the rat pup. Given its favorable safety profile, DHA is a promising candidate therapy for pediatric TBI. Further studies are needed to explore neuroprotective mechanisms of DHA after developmental TBI.

  8. Dietary Docosahexaenoic Acid Improves Cognitive Function, Tissue Sparing, and Magnetic Resonance Imaging Indices of Edema and White Matter Injury in the Immature Rat after Traumatic Brain Injury

    PubMed Central

    Requena, Daniela F.; Abdullah, Osama M.; Casper, T. Charles; Beachy, Joanna; Malleske, Daniel; Pauly, James R.

    2016-01-01

    Abstract Traumatic brain injury (TBI) is the leading cause of acquired neurologic disability in children. Specific therapies to treat acute TBI are lacking. Cognitive impairment from TBI may be blunted by decreasing inflammation and oxidative damage after injury. Docosahexaenoic acid (DHA) decreases cognitive impairment, oxidative stress, and white matter injury in adult rats after TBI. Effects of DHA on cognitive outcome, oxidative stress, and white matter injury in the developing rat after experimental TBI are unknown. We hypothesized that DHA would decrease early inflammatory markers and oxidative stress, and improve cognitive, imaging and histologic outcomes in rat pups after controlled cortical impact (CCI). CCI or sham surgery was delivered to 17 d old male rat pups exposed to DHA or standard diet for the duration of the experiments. DHA was introduced into the dam diet the day before CCI to allow timely DHA delivery to the pre-weanling pups. Inflammatory cytokines and nitrates/nitrites were measured in the injured brains at post-injury Day (PID) 1 and PID2. Morris water maze (MWM) testing was performed at PID41-PID47. T2-weighted and diffusion tensor imaging studies were obtained at PID12 and PID28. Tissue sparing was calculated histologically at PID3 and PID50. DHA did not adversely affect rat survival or weight gain. DHA acutely decreased oxidative stress and increased anti-inflammatory interleukin 10 in CCI brains. DHA improved MWM performance and lesion volume late after injury. At PID12, DHA decreased T2-imaging measures of cerebral edema and decreased radial diffusivity, an index of white matter injury. DHA improved short- and long-term neurologic outcomes after CCI in the rat pup. Given its favorable safety profile, DHA is a promising candidate therapy for pediatric TBI. Further studies are needed to explore neuroprotective mechanisms of DHA after developmental TBI. PMID:26247583

  9. Correlation Between Bladder Pain Syndrome/Interstitial Cystitis and Pelvic Inflammatory Disease

    PubMed Central

    Chung, Shiu-Dong; Chang, Chao-Hsiang; Hung, Peir-Haur; Chung, Chi-Jung; Muo, Chih-Hsin; Huang, Chao-Yuan

    2015-01-01

    Abstract Pelvic inflammatory disease (PID) has been investigated in Western countries and identified to be associated with chronic pelvic pain and inflammation. Bladder pain syndrome/interstitial cystitis (BPS/IC) is a complex syndrome that is significantly more prevalent in women than in men. Chronic pelvic pain is a main symptom of BPS/IC, and chronic inflammation is a major etiology of BPS/IC. This study aimed to investigate the correlation between BPS/IC and PID using a population-based dataset. We constructed a case–control study from the Taiwan National Health Insurance program. The case cohort comprised 449 patients with BPS/IC, and 1796 randomly selected subjects (about 1:4 matching) were used as controls. A Multivariate logistic regression model was constructed to estimate the association between BPS/IC and PID. Of the 2245 sampled subjects, a significant difference was observed in the prevalence of PID between BPS/IC cases and controls (41.7% vs 15.4%, P < 0.001). Multivariate logistic regression analysis revealed that the odds ratio (OR) for PID among cases was 3.69 (95% confidence interval [CI]: 2.89–4.71). Furthermore, the ORs for PID among BPS/IC cases were 4.52 (95% CI: 2.55–8.01), 4.31 (95% CI: 2.91–6.38), 3.00 (95% CI: 1.82–4.94), and 5.35 (95% CI: 1.88–15.20) in the <35, 35–49, 50–64, and >65 years age groups, respectively, after adjusting for geographic region, irritable bowel syndrome, and hypertension. Joint effect was also noted, specifically when patients had both PID and irritable bowel disease with OR of 10.5 (95% CI: 4.88–22.50). This study demonstrated a correlation between PID and BPS/IC. Clinicians treating women with PID should be alert to BPS/IC-related symptoms in the population. PMID:26579800

  10. A statistical mechanical approach to restricted integer partition functions

    NASA Astrophysics Data System (ADS)

    Zhou, Chi-Chun; Dai, Wu-Sheng

    2018-05-01

    The main aim of this paper is twofold: (1) suggesting a statistical mechanical approach to the calculation of the generating function of restricted integer partition functions which count the number of partitions—a way of writing an integer as a sum of other integers under certain restrictions. In this approach, the generating function of restricted integer partition functions is constructed from the canonical partition functions of various quantum gases. (2) Introducing a new type of restricted integer partition functions corresponding to general statistics which is a generalization of Gentile statistics in statistical mechanics; many kinds of restricted integer partition functions are special cases of this restricted integer partition function. Moreover, with statistical mechanics as a bridge, we reveal a mathematical fact: the generating function of restricted integer partition function is just the symmetric function which is a class of functions being invariant under the action of permutation groups. Using this approach, we provide some expressions of restricted integer partition functions as examples.

  11. Design of nonlinear PID controller and nonlinear model predictive controller for a continuous stirred tank reactor.

    PubMed

    Prakash, J; Srinivasan, K

    2009-07-01

    In this paper, the authors have represented the nonlinear system as a family of local linear state space models, local PID controllers have been designed on the basis of linear models, and the weighted sum of the output from the local PID controllers (Nonlinear PID controller) has been used to control the nonlinear process. Further, Nonlinear Model Predictive Controller using the family of local linear state space models (F-NMPC) has been developed. The effectiveness of the proposed control schemes has been demonstrated on a CSTR process, which exhibits dynamic nonlinearity.

  12. Condom Use and the Risk of Recurrent Pelvic Inflammatory Disease, Chronic Pelvic Pain, or Infertility Following an Episode of Pelvic Inflammatory Disease

    PubMed Central

    Ness, Roberta B.; Randall, Hugh; Richter, Holly E.; Peipert, Jeffrey F.; Montagno, Andrea; Soper, David E.; Sweet, Richard L.; Nelson, Deborah B.; Schubeck, Diane; Hendrix, Susan L.; Bass, Debra C.; Kip, Kevin E.

    2004-01-01

    Among 684 sexually active women with pelvic inflammatory disease (PID) followed up for a mean of 35 months, we related contraceptive use to self-reported PID recurrence, chronic pelvic pain, and infertility. Persistent use of condoms during the study reduced the risk of recurrent PID, chronic pelvic pain, and infertility. Consistent condom use (about 60% of encounters) at baseline also reduced these risks, after adjustment for confounders, by 30% to 60%. Self-reported persistent and consistent condom use was associated with lower rates of PID sequelae. PMID:15284036

  13. A Method for Precision Closed-Loop Irrigation Using a Modified PID Control Algorithm

    NASA Astrophysics Data System (ADS)

    Goodchild, Martin; Kühn, Karl; Jenkins, Malcolm; Burek, Kazimierz; Dutton, Andrew

    2016-04-01

    The benefits of closed-loop irrigation control have been demonstrated in grower trials which show the potential for improved crop yields and resource usage. Managing water use by controlling irrigation in response to soil moisture changes to meet crop water demands is a popular approach but requires knowledge of closed-loop control practice. In theory, to obtain precise closed-loop control of a system it is necessary to characterise every component in the control loop to derive the appropriate controller parameters, i.e. proportional, integral & derivative (PID) parameters in a classic PID controller. In practice this is often difficult to achieve. Empirical methods are employed to estimate the PID parameters by observing how the system performs under open-loop conditions. In this paper we present a modified PID controller, with a constrained integral function, that delivers excellent regulation of soil moisture by supplying the appropriate amount of water to meet the needs of the plant during the diurnal cycle. Furthermore, the modified PID controller responds quickly to changes in environmental conditions, including rainfall events which can result in: controller windup, under-watering and plant stress conditions. The experimental work successfully demonstrates the functionality of a constrained integral PID controller that delivers robust and precise irrigation control. Coir substrate strawberry growing trial data is also presented illustrating soil moisture control and the ability to match water deliver to solar radiation.

  14. Monitoring System and Temperature Controlling on PID Based Poultry Hatching Incubator

    NASA Astrophysics Data System (ADS)

    Shafiudin, S.; Kholis, N.

    2018-04-01

    Poultry hatching cultivation is essential to be observed in terms of temperature stability by using artificial penetration incubator which applies On/Off control. The On/Off control produces relatively long response time to reach steady-state conditions. Moreover, how the system works makes the component worn out because the lamp is on-off periodically. Besides, the cultivation in the market is less suitable to be used in an environment which has fluctuating temperature because it may influence plant’s temperature stability. The study aims to design automatic poultry hatching cultivation that can repair the temperature’s response of plant incubator to keep stable and in line with the intended set-point temperature value by using PID controller. The method used in PID controlling is designed to identify plant using ARX (Auto Regressive eXogenous) MATLAB which is dynamic/non-linear to obtain mathematical model and PID constants value that is appropriate to system. The hardware design for PID-based egg incubator uses Arduino Uno R3, as the main controller that includes PID source, and PWM, to keep plant temperature stability, which is integrated with incandescent light actuators and sensors where DHTI 1 sensor as the reader as temperature condition and plant humidity. The result of the study showed that PID constants value of each plant is different. For parallel 15 Watt plant, Kp = 3.9956, Ki = 0.361, Kd = 0, while for parallel 25 Watt plant, the value of Kp = 5.714, Ki = 0.351, Kd = 0. The PID constants value were capable to produce stable system response which is based on set-point with steady state error’s value is around 5%, that is 2.7%. With hatching percentage of 70-80%, the hatching process is successful in air-conditioned environment (changeable).

  15. Mechanism of Inducible Nitric-oxide Synthase Dimerization Inhibition by Novel Pyrimidine Imidazoles*

    PubMed Central

    Nagpal, Latika; Haque, Mohammad M.; Saha, Amit; Mukherjee, Nirmalya; Ghosh, Arnab; Ranu, Brindaban C.; Stuehr, Dennis J.; Panda, Koustubh

    2013-01-01

    Overproduction of nitric oxide (NO) by inducible nitric-oxide synthase (iNOS) has been etiologically linked to several inflammatory, immunological, and neurodegenerative diseases. As dimerization of NOS is required for its activity, several dimerization inhibitors, including pyrimidine imidazoles, are being evaluated for therapeutic inhibition of iNOS. However, the precise mechanism of their action is still unclear. Here, we examined the mechanism of iNOS inhibition by a pyrimidine imidazole core compound and its derivative (PID), having low cellular toxicity and high affinity for iNOS, using rapid stopped-flow kinetic, gel filtration, and spectrophotometric analysis. PID bound to iNOS heme to generate an irreversible PID-iNOS monomer complex that could not be converted to active dimers by tetrahydrobiopterin (H4B) and l-arginine (Arg). We utilized the iNOS oxygenase domain (iNOSoxy) and two monomeric mutants whose dimerization could be induced (K82AiNOSoxy) or not induced (D92AiNOSoxy) with H4B to elucidate the kinetics of PID binding to the iNOS monomer and dimer. We observed that the apparent PID affinity for the monomer was 11 times higher than the dimer. PID binding rate was also sensitive to H4B and Arg site occupancy. PID could also interact with nascent iNOS monomers in iNOS-synthesizing RAW cells, to prevent their post-translational dimerization, and it also caused irreversible monomerization of active iNOS dimers thereby accomplishing complete physiological inhibition of iNOS. Thus, our study establishes PID as a versatile iNOS inhibitor and therefore a potential in vivo tool for examining the causal role of iNOS in diseases associated with its overexpression as well as therapeutic control of such diseases. PMID:23696643

  16. Primary immunodeficiency diseases in children: 15 year experience in a tertiary care medical center in Qatar.

    PubMed

    Ehlayel, Mohammad S; Bener, Abdulbari; Laban, Mohammad Abu

    2013-02-01

    Primary immunodeficiency diseases (PID) are a group of heterogeneous, rare, genetic, mainly childhood disorders that affect specific components of immune system leading to serious complications. This study is aimed at describing the prevalence and the categories of PID, the ages of onset and the diagnosis, the clinical presentations, the treatment modalities and the overall outcome of affected patients. A retrospective study was conducted on 131 pediatric patients (aged 0-14 years) diagnosed with PID at Hamad General Hospital during a 15-year period (1998-2012). Data of 131 patients (75 males & 56 females) was analyzed with an estimated prevalence of 4.7 PID patients per 100,000 children younger than 14 years of age. The most common type of PID was predominantly antibody deficiency (23.7 %), followed by other well-defined immunodeficiency syndromes (22.9 %), 19.1 % combined T and B cell immunodeficiency, but rare CVID, and no cases of complement deficiency. The mean onset age was 24.01 months and diagnosis age was 42.2 months. Recurrent infections, particularly pneumonia (48.9 %), failure to thrive (34.4 %), otitis media (26 %), sepsis (23.7 %), and chronic diarrhoea (21.4 %) were commonest presenting conditions. P. aeruginosa (15.7 %), Salmonella species (13.2 %), and Non-TB mycobacteria (13.2 %) were the most common bacterial isolates. The overall mortality rate was 21.4 % with combined immunodeficiency's accounting for 53.4 % of deaths. This study reveals that PIDs are not rare in children in Qatar; and like other studies predominantly antibody deficiencies are the most common. Strategies that reinforce awareness and education of practicing physicians, bone marrow transplantation, and establishing PID national registry should be adopted to reduce mortality and morbidity of PID patients in Qatar.

  17. Measuring trends of outpatient antibiotic use in Europe: jointly modelling longitudinal data in defined daily doses and packages.

    PubMed

    Bruyndonckx, Robin; Hens, Niel; Aerts, Marc; Goossens, Herman; Molenberghs, Geert; Coenen, Samuel

    2014-07-01

    To complement analyses of the linear trend and seasonal fluctuation of European outpatient antibiotic use expressed in defined daily doses (DDD) by analyses of data in packages, to assess the agreement between both measures and to study changes in the number of DDD per package over time. Data on outpatient antibiotic use, aggregated at the level of the active substance (WHO version 2011) were collected from 2000 to 2007 for 31 countries and expressed in DDD and packages per 1000 inhabitants per day (DID and PID, respectively). Data expressed in DID and PID were analysed separately using non-linear mixed models while the agreement between these measurements was analysed through a joint non-linear mixed model. The change in DDD per package over time was studied with a linear mixed model. Total outpatient antibiotic and penicillin use in Europe and their seasonal fluctuation significantly increased in DID, but not in PID. The use of combinations of penicillins significantly increased in DID and in PID. Broad-spectrum penicillin use did not increase significantly in DID and decreased significantly in PID. For all but one subgroup, country-specific deviations moved in the same direction whether measured in DID or PID. The correlations are not perfect. The DDD per package increased significantly over time for all but one subgroup. Outpatient antibiotic use in Europe shows contrasting trends, depending on whether DID or PID is used as the measure. The increase of the DDD per package corroborates the recommendation to adopt PID to monitor outpatient antibiotic use in Europe. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Generalized vector calculus on convex domain

    NASA Astrophysics Data System (ADS)

    Agrawal, Om P.; Xu, Yufeng

    2015-06-01

    In this paper, we apply recently proposed generalized integral and differential operators to develop generalized vector calculus and generalized variational calculus for problems defined over a convex domain. In particular, we present some generalization of Green's and Gauss divergence theorems involving some new operators, and apply these theorems to generalized variational calculus. For fractional power kernels, the formulation leads to fractional vector calculus and fractional variational calculus for problems defined over a convex domain. In special cases, when certain parameters take integer values, we obtain formulations for integer order problems. Two examples are presented to demonstrate applications of the generalized variational calculus which utilize the generalized vector calculus developed in the paper. The first example leads to a generalized partial differential equation and the second example leads to a generalized eigenvalue problem, both in two dimensional convex domains. We solve the generalized partial differential equation by using polynomial approximation. A special case of the second example is a generalized isoperimetric problem. We find an approximate solution to this problem. Many physical problems containing integer order integrals and derivatives are defined over arbitrary domains. We speculate that future problems containing fractional and generalized integrals and derivatives in fractional mechanics will be defined over arbitrary domains, and therefore, a general variational calculus incorporating a general vector calculus will be needed for these problems. This research is our first attempt in that direction.

  19. Patient-centred screening for primary immunodeficiency, a multi-stage diagnostic protocol designed for non-immunologists: 2011 update

    PubMed Central

    de Vries, E

    2012-01-01

    Members of the European Society for Immunodeficiencies (ESID) and other colleagues have updated the multi-stage expert-opinion-based diagnostic protocol for non-immunologists incorporating newly defined primary immunodeficiency diseases (PIDs). The protocol presented here aims to increase the awareness of PIDs among doctors working in different fields. Prompt identification of PID is important for prognosis, but this may not be an easy task. The protocol therefore starts from the clinical presentation of the patient. Because PIDs may present at all ages, this protocol is aimed at both adult and paediatric physicians. The multi-stage design allows cost-effective screening for PID of the large number of potential cases in the early phases, with more expensive tests reserved for definitive classification in collaboration with a specialist in the field of immunodeficiency at a later stage. PMID:22132890

  20. Proportional integral derivative, modeling and ways of stabilization for the spark plasma sintering process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manière, Charles; Lee, Geuntak; Olevsky, Eugene A.

    The stability of the proportional–integral–derivative (PID) control of temperature in the spark plasma sintering (SPS) process is investigated. The PID regulations of this process are tested for different SPS tooling dimensions, physical parameters conditions, and areas of temperature control. It is shown that the PID regulation quality strongly depends on the heating time lag between the area of heat generation and the area of the temperature control. Tooling temperature rate maps are studied to reveal potential areas for highly efficient PID control. The convergence of the model and experiment indicates that even with non-optimal initial PID coefficients, it is possiblemore » to reduce the temperature regulation inaccuracy to less than 4 K by positioning the temperature control location in highly responsive areas revealed by the finite-element calculations of the temperature spatial distribution.« less

  1. Trait Variance and Response Style Variance in the Scales of the Personality Inventory for DSM-5 (PID-5).

    PubMed

    Ashton, Michael C; de Vries, Reinout E; Lee, Kibeom

    2017-01-01

    Using self- and observer reports on the Personality Inventory for DSM-5 (PID-5) and the HEXACO Personality Inventory-Revised (HEXACO-PI-R), we identified for each inventory several trait dimensions (each defined by both self- and observer reports on the facet-level scales belonging to the same domain) and 2 source dimensions (each defined by self-reports or by observer reports, respectively, on all facet-level scales). Results (N = 217) showed that the source dimensions of the PID-5 were very large (much larger than those of the HEXACO-PI-R), and suggest that self-report (or observer report) response styles substantially inflate the intercorrelations and the alpha reliabilities of the PID-5 scales. We discuss the meaning and the implications of the large PID-5 source components, and we suggest some methods of controlling their influence.

  2. Preimplantation genetic diagnosis and the 'new' eugenics.

    PubMed Central

    King, D S

    1999-01-01

    Preimplantation genetic diagnosis (PID) is often seen as an improvement upon prenatal testing. I argue that PID may exacerbate the eugenic features of prenatal testing and make possible an expanded form of free-market eugenics. The current practice of prenatal testing is eugenic in that its aim is to reduce the numbers of people with genetic disorders. Due to social pressures and eugenic attitudes held by clinical geneticists in most countries, it results in eugenic outcomes even though no state coercion is involved. I argue that technological advances may soon make PID widely accessible. Because abortion is not involved, and multiple embryos are available, PID is radically more effective as a tool of genetic selection. It will also make possible selection on the basis of non-pathological characteristics, leading, potentially, to a full-blown free-market eugenics. For these reasons, I argue that PID should be strictly regulated. PMID:10226925

  3. Defect generation in electronic devices under plasma exposure: Plasma-induced damage

    NASA Astrophysics Data System (ADS)

    Eriguchi, Koji

    2017-06-01

    The increasing demand for higher performance of ULSI circuits requires aggressive shrinkage of device feature sizes in accordance with Moore’s law. Plasma processing plays an important role in achieving fine patterns with anisotropic features in metal-oxide-semiconductor field-effect transistors (MOSFETs). This article comprehensively addresses the negative aspect of plasma processing — plasma-induced damage (PID). PID naturally not only modifies the surface morphology of materials but also degrades the performance and reliability of MOSFETs as a result of defect generation in the materials. Three key mechanisms of PID, i.e., physical, electrical, and photon-irradiation interactions, are overviewed in terms of modeling, characterization techniques, and experimental evidence reported so far. In addition, some of the emerging topics — control of parameter variability in ULSI circuits caused by PID and recovery of PID — are discussed as future perspectives.

  4. Proportional integral derivative, modeling and ways of stabilization for the spark plasma sintering process

    DOE PAGES

    Manière, Charles; Lee, Geuntak; Olevsky, Eugene A.

    2017-04-21

    The stability of the proportional–integral–derivative (PID) control of temperature in the spark plasma sintering (SPS) process is investigated. The PID regulations of this process are tested for different SPS tooling dimensions, physical parameters conditions, and areas of temperature control. It is shown that the PID regulation quality strongly depends on the heating time lag between the area of heat generation and the area of the temperature control. Tooling temperature rate maps are studied to reveal potential areas for highly efficient PID control. The convergence of the model and experiment indicates that even with non-optimal initial PID coefficients, it is possiblemore » to reduce the temperature regulation inaccuracy to less than 4 K by positioning the temperature control location in highly responsive areas revealed by the finite-element calculations of the temperature spatial distribution.« less

  5. Design And Implementation Of PID Controller Using Relay Feedback On TRMS (Twin Rotor MIMO System)

    NASA Astrophysics Data System (ADS)

    Shah, Dipesh H.

    2011-12-01

    Today, many process control problems can be adequately and routinely solved by conventional PID control strategies. The overriding reason that the PID controller is so widely accepted is its simple structure which has proved to be very robust with regard to many commonly met process control problems as for instance disturbances and nonlinearities. Relay feedback methods have been widely used in tuning proportional-integral-derivative controllers due to its closed loop nature. In this work, Relay based PID controller is designed and successfully implemented on TRMS (Twin Rotor MIMO System) in SISO and MIMO configurations. The performance of a Relay based PID controller for control of TRMS is investigated and performed satisfactorily. The system shares some features with a helicopter, such as important interactions between the vertical and horizontal motions. The RTWT toolbox in the MATLAB environment is used to perform real-time experiments.

  6. A Practical Approach to the Diagnosis of Pelvic Inflammatory Disease

    PubMed Central

    Jaiyeoba, Oluwatosin; Soper, David E.

    2011-01-01

    The diagnosis of acute pelvic inflammatory disease (PID) is usually based on clinical criteria and can be challenging for even the most astute clinicians. Although diagnostic accuracy is advocated, antibiotic treatment should be instituted if there is a diagnosis of cervicitis or suspicion of acute PID. Currently, no single test or combination of diagnostic indicators have been found to reliably predict PID, and laparoscopy cannot be recommended as a first line tool for PID diagnosis. For this reason, the clinician is left with maintaining a high index of suspicion for the diagnosis as he/she evaluates the lower genital tract for inflammation and the pelvic organs for tenderness in women with genital tract symptoms and a risk for sexually transmitted infection. This approach should minimize treating women without PID with antibiotics and optimize the diagnosis in a practical and cost-effective way. PMID:21822367

  7. Greenhouse irrigation control system design based on ZigBee and fuzzy PID technology

    NASA Astrophysics Data System (ADS)

    Zhou, Bing; Yang, Qiliang; Liu, Kenan; Li, Peiqing; Zhang, Jing; Wang, Qijian

    In order to achieve the water demand information accurately detect of the greenhouse crop and its precision irrigation automatic control, this article has designed a set of the irrigated control system based on ZigBee and fuzzy PID technology, which composed by the soil water potential sensor, CC2530F256 wireless microprocessor, IAR Embedded Workbench software development platform. And the time of Irrigation as the output .while the amount of soil water potential and crop growth cycle as the input. The article depended on Greenhouse-grown Jatropha to verify the object, the results show that the system can irrigate timely and appropriately according to the soil water potential and water demend of the different stages of Jatropha growth , which basically meet the design requirements. Therefore, the system has broad application prospects in the amount of greenhouse crop of fine control irrigation.

  8. Efficient Remainder Rule

    ERIC Educational Resources Information Center

    Firozzaman, Firoz; Firoz, Fahim

    2017-01-01

    Understanding the solution of a problem may require the reader to have background knowledge on the subject. For instance, finding an integer which, when divided by a nonzero integer leaves a remainder; but when divided by another nonzero integer may leave a different remainder. To find a smallest positive integer or a set of integers following the…

  9. Mutations in CsPID encoding a Ser/Thr protein kinase are responsible for round leaf shape in cucumber (Cucumis sativus L.)

    USDA-ARS?s Scientific Manuscript database

    Leaf shape is an important plant architecture trait that is affected by plant hormones, especially auxin. In Arabidopsis, PINOID (PID), a regulator for the auxin polar transporter PIN (PIN-FORMED) affects leaf shape formation, but this function of PID in crop plants has not been well studied. From a...

  10. Mechanism-based strategies for the management of autoimmunity and immune dysregulation in primary immunodeficiencies

    PubMed Central

    Walter, Jolan E; Farmer, Jocelyn R; Foldvari, Zsofia; Torgerson, Troy R; Cooper, Megan A

    2016-01-01

    A broad spectrum of autoimmunity is now well described in patients with primary immunodeficiencies (PIDs). Management of autoimmune disease in the background of PID is particularly challenging given the seemingly discordant goals of immune support and immune suppression. Our growing ability to define the molecular underpinnings of immune dysregulation has facilitated novel targeted therapeutics. This review focuses on mechanism-based treatment strategies for the most common autoimmune and inflammatory complications of PID including autoimmune cytopenias, rheumatologic disease, and gastrointestinal disease. We aim to provide guidance regarding the rational use of these agents in the complex PID patient population. PMID:27836058

  11. Current Perspectives on Primary Immunodeficiency Diseases

    PubMed Central

    Kumar, Arvind; Teuber, Suzanne S.; Gershwin, M. Eric

    2006-01-01

    Since the original description of X-linked agammaglobulinemia in 1952, the number of independent primary immunodeficiency diseases (PIDs) has expanded to more than 100 entities. By definition, a PID is a genetically determined disorder resulting in enhanced susceptibility to infectious disease. Despite the heritable nature of these diseases, some PIDs are clinically manifested only after prerequisite environmental exposures but they often have associated malignant, allergic, or autoimmune manifestations. PIDs must be distinguished from secondary or acquired immunodeficiencies, which are far more common. In this review, we will place these immunodeficiencies in the context of both clinical and laboratory presentations as well as highlight the known genetic basis. PMID:17162365

  12. X-ray imaging using amorphous selenium: a photoinduced discharge readout method for digital mammography.

    PubMed

    Rowlands, J A; Hunter, D M; Araj, N

    1991-01-01

    A new digital image readout method for electrostatic charge images on photoconductive plates is described. The method can be used to read out images on selenium plates similar to those used in xeromammography. The readout method, called the air-gap photoinduced discharge method (PID), discharges the latent image pixel by pixel and measures the charge. The PID readout method, like electrometer methods, is linear. However, the PID method permits much better resolution than scanning electrometers while maintaining quantum limited performance at high radiation exposure levels. Thus the air-gap PID method appears to be uniquely superior for high-resolution digital imaging tasks such as mammography.

  13. Optimising multi-product multi-chance-constraint inventory control system with stochastic period lengths and total discount under fuzzy purchasing price and holding costs

    NASA Astrophysics Data System (ADS)

    Allah Taleizadeh, Ata; Niaki, Seyed Taghi Akhavan; Aryanezhad, Mir-Bahador

    2010-10-01

    While the usual assumptions in multi-periodic inventory control problems are that the orders are placed at the beginning of each period (periodic review) or depending on the inventory level they can happen at any time (continuous review), in this article, we relax these assumptions and assume that the periods between two replenishments of the products are independent and identically distributed random variables. Furthermore, assuming that the purchasing price are triangular fuzzy variables, the quantities of the orders are of integer-type and that there are space and service level constraints, total discount are considered to purchase products and a combination of back-order and lost-sales are taken into account for the shortages. We show that the model of this problem is a fuzzy mixed-integer nonlinear programming type and in order to solve it, a hybrid meta-heuristic intelligent algorithm is proposed. At the end, a numerical example is given to demonstrate the applicability of the proposed methodology and to compare its performance with one of the existing algorithms in real world inventory control problems.

  14. Boundary layer flow of MHD generalized Maxwell fluid over an exponentially accelerated infinite vertical surface with slip and Newtonian heating at the boundary

    NASA Astrophysics Data System (ADS)

    Imran, M. A.; Riaz, M. B.; Shah, N. A.; Zafar, A. A.

    2018-03-01

    The aim of this article is to investigate the unsteady natural convection flow of Maxwell fluid with fractional derivative over an exponentially accelerated infinite vertical plate. Moreover, slip condition, radiation, MHD and Newtonian heating effects are also considered. A modern definition of fractional derivative operator recently introduced by Caputo and Fabrizio has been used to formulate the fractional model. Semi analytical solutions of the dimensionless problem are obtained by employing Stehfest's and Tzou's algorithms in order to find the inverse Laplace transforms for temperature and velocity fields. Temperature and rate of heat transfer for non-integer and integer order derivatives are computed and reduced to some known solutions from the literature. Finally, in order to get insight of the physical significance of the considered problem regarding velocity and Nusselt number, some graphical illustrations are made using Mathcad software. As a result, in comparison between Maxwell and viscous fluid (fractional and ordinary) we found that viscous (fractional and ordinary) fluids are swiftest than Maxwell (fractional and ordinary) fluids.

  15. JAXA astronaut and Expedition 28 crew member Satoshi Furukawa

    NASA Image and Video Library

    2010-09-17

    PHOTO DATE: 09-17-10 LOCATION: Bldg. 9NW - ISS Mockups SUBJECT: JAXA astronaut and Expedition 28 crew member Satoshi Furukawa during P HRF Integ Cardio Integration Ops training WORK ORDER: 02810-BS__HRFSATOSHI_09-17-10 PHOTOGRAPHER: BILL STAFFORD

  16. Random crystal field effects on the integer and half-integer mixed-spin system

    NASA Astrophysics Data System (ADS)

    Yigit, Ali; Albayrak, Erhan

    2018-05-01

    In this work, we have focused on the random crystal field effects on the phase diagrams of the mixed spin-1 and spin-5/2 Ising system obtained by utilizing the exact recursion relations (ERR) on the Bethe lattice (BL). The distribution function P(Di) = pδ [Di - D(1 + α) ] +(1 - p) δ [Di - D(1 - α) ] is used to randomize the crystal field.The phase diagrams are found to exhibit second- and first-order phase transitions depending on the values of α, D and p. It is also observed that the model displays tricritical point, isolated point, critical end point and three compensation temperatures for suitable values of the system parameters.

  17. Attentiveness of pediatricians to primary immunodeficiency disorders

    PubMed Central

    2012-01-01

    Background Primary immunodeficiency (PID) is a cluster of serious disorders that requires special alertness on the part of the medical staff for prompt diagnosis and management of the patient. This study explored PID knowledge and experience among pediatricians of wide educational backgrounds, practicing in the United Arab Emirates (UAE). Method A self-administered questionnaire was used to determine the competency of pediatricians in their knowledge of PID disorders. This study questionnaire included questions on PID signs and symptoms, syndromes associated with immunodeficiency, screening tests, interpreting laboratory tests and case management. The participants were 263 pediatricians of diverse education working in the 27 governmental hospitals in all regions of UAE. Results The overall performance of the pediatricians did not differ based on their age, gender, origin of certification, rank, or years of experience. Of the 50 questions, 20% of pediatricians answered correctly <60% of the questions, 76% answered correctly 60 to 79% of the questions, and 4% answered correctly ≥80% of the questions. Seventeen of the 19 PID signs and symptoms were identified by 55 to 97%. Four of 5 syndromes associated with immunodeficiency were identified by 50 to 90%. Appropriate screening tests were chosen by 64 to 96%. Attention to the laboratory reference range values as function of patient age was notably limited. Conclusions There was a noteworthy deficiency in PID work-up. Therefore, implementing effective educational strategies is needed to improve the competency of pediatricians to diagnose and manage PID disorders. PMID:22846098

  18. The impact of underreporting and overreporting on the validity of the Personality Inventory for DSM-5 (PID-5): A simulation analog design investigation.

    PubMed

    Dhillon, Sonya; Bagby, R Michael; Kushner, Shauna C; Burchett, Danielle

    2017-04-01

    The Personality Inventory for DSM-5 (PID-5) is a 220-item self-report instrument that assesses the alternative model of personality psychopathology in Section III (Emerging Measures and Models) of DSM-5 . Despite its relatively recent introduction, the PID-5 has generated an impressive accumulation of studies examining its psychometric properties, and the instrument is also already widely and frequently used in research studies. Although the PID-5 is psychometrically sound overall, reviews of this instrument express concern that this scale does not possess validity scales to detect invalidating levels of response bias, such as underreporting and overreporting. McGee Ng et al. (2016), using a "known-groups" (partial) criterion design, demonstrated that both underreporting and overreporting grossly affect mean scores on PID-5 scales. In the current investigation, we replicate these findings using an analog simulation design. An important extension to this replication study was the finding that the construct validity of the PID-5 was also significantly compromised by response bias, with statistically significant attenuation noted in validity coefficients of the PID-5 domain scales with scales from other instruments measuring congruent constructs. This attenuation was found for underreporting and overreporting bias. We believe there is a need to develop validity scales to screen for data-distorting response bias in research contexts and in clinical assessments where response bias is likely or otherwise suspected. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. History of Primary Immunodeficiency Diseases in Iran

    PubMed Central

    Aghamohammadi, Asghar; Moin, Mostafa; Rezaei, Nima

    2010-01-01

    Pediatric immunology came into sight in the second half of 20th century, when pediatricians and basic immunologists began to give attention to diagnosis and treatment of children with primary immunodeficiency diseases (PIDs). Understanding the genetic and mechanistic basis of PIDs provides unique insight into the functioning of the immune system. By progress in basic and clinical immunology, many infrastructural organizations and academic centers have been established in many countries worldwide to focus on training and research on the immune system and related disorders. Along with progress in basic and clinical immunology in the world, pediatric immunology had a good progress in Iran during the last 33-year period. Now, patients with PIDs can benefit from multidisciplinary comprehensive care, which is provided by clinical immunologists in collaboration with other specialists. Patients with history of recurrent and/or chronic infections suggestive of PIDs are evaluated by standard and research-based testing and receive appropriate treatment. The progress in PIDs can be described in three periods. Development of training program for clinical fellowship in allergy and immunology, multidisciplinary and international collaborative projects, primary immunodeficiency diseases textbooks, meetings on immunodeficiency disorders, improvement in diagnosis and treatment, and construction of Iranian primary immunodeficiency association, Students' research group for immunodeficiencies, Iranian primary immunodeficiency registry, and the immunological societies and centers were the main activities on PIDs during these years. In this article, we review the growth of modern pediatric immunology and PIDs status in Iran. PMID:23056678

  20. Prevention of infection in children and adolescents with primary immunodeficiency disorders.

    PubMed

    Papadopoulou-Alataki, Efimia; Hassan, Amel; Davies, E Graham

    2012-12-01

    Primary Immunodeficiency diseases (PIDs) are a heterogenous group of inherited disorders that may involve one or multiple components of the immune system. PIDs are uncommon, chronic and severe disorders, in which patients cannot mount a sufficiently protective immune response, leading to an increased susceptibility to infections. This review addresses the current practices for the prevention of infection in children and adolescents with PIDs, particular covering immunisations and antimicrobial prophylaxis. Over recent years, there have been major advances in molecular and cellular understanding in the field of PIDs. Many different disorders are recognised with variable spectra of infection susceptibility depending on the particular aspects of the immune response that are affected. Immunoglobulin prophylaxis is the mainstay of treatment for PIDs and provides passive protection. Prophylactic antimicrobials are efficacious in children and adolescents with predominant defects in primary T cell immunodeficiency diseases and phagocytic disorders, and also with predominant defects in antibody production. Prophylactic antibiotics are suggested for patients with antibody deficiency diseases if recurrent infections exceed three per year, if severe infections occur despite adequate immunoglobulin replacement and in hypogammaglobulinaemic patients who have bronchiectasis. Certain immunisations are effective in antibody deficiencies, T cell deficiencies, complement deficiencies and phagocytic disorders. There are remarkably few published data relating to clinical management aimed at preventing infectious complications in children and adolescents with PIDs. The cornerstones of the prevention of infection in most PID patients are: antimicrobial prophylaxis, appropriate vaccination, immunoglobulin replacement, for the more severe cases, and regular ongoing follow-up.

  1. An Expansion Formula with Higher-Order Derivatives for Fractional Operators of Variable Order

    PubMed Central

    Almeida, Ricardo

    2013-01-01

    We obtain approximation formulas for fractional integrals and derivatives of Riemann-Liouville and Marchaud types with a variable fractional order. The approximations involve integer-order derivatives only. An estimation for the error is given. The efficiency of the approximation method is illustrated with examples. As applications, we show how the obtained results are useful to solve differential equations, and problems of the calculus of variations that depend on fractional derivatives of Marchaud type. PMID:24319382

  2. On the Existence of Non-Oscillatory Phase Functions for Second Order Ordinary Differential Equations in the High-Frequency Regime

    DTIC Science & Technology

    2014-08-04

    Chebyshev coefficients of both r and q decay exponentially, although those of r decay at a slightly slower rate. 10.2. Evaluation of Legendre polynomials ...In this experiment, we compare the cost of evaluating Legendre polynomials of large order using the standard recurrence relation with the cost of...doing so with a nonoscillatory phase function. For any integer n ě 0, the Legendre polynomial Pnpxq of order n is a solution of the second order

  3. Comments on X. Yin, A. Wen, Y. Chen, and T. Wang, `Studies in an optical millimeter-wave generation scheme via two parallel dual-parallel Mach-Zehnder modulators', Journal of Modern Optics, 58(8), 2011, pp. 665-673

    NASA Astrophysics Data System (ADS)

    Hasan, Mehedi; Maldonado-Basilio, Ramón; Hall, Trevor J.

    2015-04-01

    Yin et al. have described an innovative filter-less optical millimeter-wave generation scheme for octotupling of a 10 GHz RF oscillator, or sedecimtupling of a 5 GHz RF oscillator using two parallel dual-parallel Mach-Zehnder modulators (DP-MZMs). The great merit of their design is the suppression of all harmonics except those of order ? (octotupling) or all harmonics except those of order ? (sedecimtupling), where ? is an integer. A demerit of their scheme is the requirement to set a precise RF signal modulation index in order to suppress the zeroth order optical carrier. The purpose of this comment is to show that, in the case of the octotupling function, all harmonics may be suppressed except those of order ?, where ? is an odd integer, by the simple addition of an optical ? phase shift between the two DP-MZMs and an adjustment of the RF drive phases. Since the carrier is suppressed in the modified architecture, the octotupling circuit is thereby released of the strict requirement to set the drive level to a precise value without any significant increase in circuit complexity.

  4. COED Transactions, Vol. X, No. 10, October 1978. Simulation of a Sampled-Data System on a Hybrid Computer.

    ERIC Educational Resources Information Center

    Mitchell, Eugene E., Ed.

    The simulation of a sampled-data system is described that uses a full parallel hybrid computer. The sampled data system simulated illustrates the proportional-integral-derivative (PID) discrete control of a continuous second-order process representing a stirred-tank. The stirred-tank is simulated using continuous analog components, while PID…

  5. On parameters identification of computational models of vibrations during quiet standing of humans

    NASA Astrophysics Data System (ADS)

    Barauskas, R.; Krušinskienė, R.

    2007-12-01

    Vibration of the center of pressure (COP) of human body on the base of support during quiet standing is a very popular clinical research, which provides useful information about the physical and health condition of an individual. In this work, vibrations of COP of a human body in forward-backward direction during still standing are generated using controlled inverted pendulum (CIP) model with a single degree of freedom (dof) supplied with proportional, integral and differential (PID) controller, which represents the behavior of the central neural system of a human body and excited by cumulative disturbance vibration, generated within the body due to breathing or any other physical condition. The identification of the model and disturbance parameters is an important stage while creating a close-to-reality computational model able to evaluate features of disturbance. The aim of this study is to present the CIP model parameters identification approach based on the information captured by time series of the COP signal. The identification procedure is based on an error function minimization. Error function is formulated in terms of time laws of computed and experimentally measured COP vibrations. As an alternative, error function is formulated in terms of the stabilogram diffusion function (SDF). The minimization of error functions is carried out by employing methods based on sensitivity functions of the error with respect to model and excitation parameters. The sensitivity functions are obtained by using the variational techniques. The inverse dynamic problem approach has been employed in order to establish the properties of the disturbance time laws ensuring the satisfactory coincidence of measured and computed COP vibration laws. The main difficulty of the investigated problem is encountered during the model validation stage. Generally, neither the PID controller parameter set nor the disturbance time law are known in advance. In this work, an error function formulated in terms of time derivative of disturbance torque has been proposed in order to obtain PID controller parameters, as well as the reference time law of the disturbance. The disturbance torque is calculated from experimental data using the inverse dynamic approach. Experiments presented in this study revealed that vibrations of disturbance torque and PID controller parameters identified by the method may be qualified as feasible in humans. Presented approach may be easily extended to structural models with any number of dof or higher structural complexity.

  6. 77 FR 43063 - Affirmation of Vertical Datum for Surveying and Mapping Activities for the Territory of Puerto Rico

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-23

    ... National Water Level Observation Network (NWLON) for bench marks designated 975 5371 A TIDAL (PID TV1513) (1.334 meters), located at La Puntilla, San Juan Puerto Rico, 975 2235 D (PID DN8624) (0.973 meters), located on Culebra Island, 975 2695 A (PID DN8535) (1.962 meters), located at Esperanza, Vieques Island...

  7. Variable Structure PID Control to Prevent Integrator Windup

    NASA Technical Reports Server (NTRS)

    Hall, C. E.; Hodel, A. S.; Hung, J. Y.

    1999-01-01

    PID controllers are frequently used to control systems requiring zero steady-state error while maintaining requirements for settling time and robustness (gain/phase margins). PID controllers suffer significant loss of performance due to short-term integrator wind-up when used in systems with actuator saturation. We examine several existing and proposed methods for the prevention of integrator wind-up in both continuous and discrete time implementations.

  8. Mannose-Binding Lectin Protein Deficiency Among Patients with Primary Immunodeficiency Disease Receiving IVIG Therapy.

    PubMed

    Azizi, Gholamreza; Kiaee, Fatemeh; Yaslianifard, Somaye; Rafiemanesh, Hosein; Mohammadikhajehdehi, Sara; Mohammadi, Hamed; Miresmaeeli, Seyed Sakineh; Pour, Leila H; Poor Heravi, Sina Abdolrahim; Sharifi, Laleh; Yazdani, Reza; Abolhassani, Hassan; Aghamohammadi, Asghar

    2018-02-13

    Primary immunodeficiencies (PIDs) are inherited disorders in which one or several components of the immune system are defective. Immunoglobulin replacement therapy is the mainstay of treatment for patients with impaired antibody production. However, recurrent infections would continue to occur in some patients due to the other high frequent concomitant defects, such as mannose-binding lectin (MBL) deficiency. A total of 51 PID patients participated in this cross-sectional study. A detailed questionnaire was completed by interviewing patients in order to record demographic, clinical and laboratory data. The levels of MBL were determined in the serums of patients by a sandwich enzyme-linked immunosorbent assay (ELISA) technique. MBL deficiency was found in 29.4% of cases; 11.8% patients had mild, 3.9% patients had moderate and 13.7% patients had severe MBL deficiency. In patients with MBL deficiency, the rate of meningitis, sepsis, pneumonia, and otitis media was higher than patients with normal MBL levels. Immunoglobulin replacement therapy reduced the rate of infectious complications in PID patients; however, these reductions were more apparent in patients with normal MBL levels than patients with MBL deficiency. Antibody deficient patients with a concomitant immune defect in MBL production have higher rates of recurrent infections despite receiving Immunoglobulin replacement therapy. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Persistent Identifiers in Earth science data management environments

    NASA Astrophysics Data System (ADS)

    Weigel, Tobias; Stockhause, Martina; Lautenschlager, Michael

    2014-05-01

    Globally resolvable Persistent Identifiers (PIDs) that carry additional context information (which can be any form of metadata) are increasingly used by data management infrastructures for fundamental tasks. The notion of a Persistent Identifier is originally an abstract concept that aims to provide identifiers that are quality-controlled and maintained beyond the life time of the original issuer, for example through the use of redirection mechanisms. Popular implementations of the PID concept are for example the Handle System and the DOI System based on it. These systems also move beyond the simple identification concept by providing facilities that can hold additional context information. Not only in the Earth sciences, data managers are increasingly attracted to PIDs because of the opportunities these facilities provide; however, long-term viable principles and mechanisms for efficient organization of PIDs and context information are not yet available or well established. In this respect, promising techniques are to type the information that is associated with PIDs and to construct actionable collections of PIDs. There are two main drivers for extended PID usage: Earth science data management middleware use cases and applications geared towards scientific end-users. Motivating scenarios from data management include hierarchical data and metadata management, consistent data tracking and improvements in the accountability of processes. If PIDs are consistently assigned to data objects, context information can be carried over to subsequent data life cycle stages much easier. This can also ease data migration from one major curation domain to another, e.g. from early dissemination within research communities to formal publication and long-term archival stages, and it can help to document processes across technical and organizational boundaries. For scientific end users, application scenarios include for example more personalized data citation and improvements in the amount of context available for unfamiliar datasets. We can see how Earth system model data is spatially and temporally transformed to better fit the differing scenarios relevant in consecutive life cycle stages. At the end, users often want to cite and use distinct subsets of data which are disseminated through e-science infrastructures. If actionable collections of fine-granular PIDs are available, much more precise citation and use can be supported. This can also help to establish interoperable input and output references for processing tasks during intermediate life cycle stages. The current working draft API of the Research Data Alliance's working group on PID Information Types combined with more elaborate collection mechanisms can provide the necessary foundations and tools to enable wide-spread use of PIDs for data life cycle management and user applications. This contribution will highlight some of the available mechanisms and existing efforts with particular focus on applications for institutional data management and e-science infrastructures such as the Earth System Grid Federation.

  10. Compression embedding

    DOEpatents

    Sandford, M.T. II; Handel, T.G.; Bradley, J.N.

    1998-07-07

    A method and apparatus for embedding auxiliary information into the digital representation of host data created by a lossy compression technique and a method and apparatus for constructing auxiliary data from the correspondence between values in a digital key-pair table with integer index values existing in a representation of host data created by a lossy compression technique are disclosed. The methods apply to data compressed with algorithms based on series expansion, quantization to a finite number of symbols, and entropy coding. Lossy compression methods represent the original data as ordered sequences of blocks containing integer indices having redundancy and uncertainty of value by one unit, allowing indices which are adjacent in value to be manipulated to encode auxiliary data. Also included is a method to improve the efficiency of lossy compression algorithms by embedding white noise into the integer indices. Lossy compression methods use loss-less compression to reduce to the final size the intermediate representation as indices. The efficiency of the loss-less compression, known also as entropy coding compression, is increased by manipulating the indices at the intermediate stage. Manipulation of the intermediate representation improves lossy compression performance by 1 to 10%. 21 figs.

  11. Compression embedding

    DOEpatents

    Sandford, II, Maxwell T.; Handel, Theodore G.; Bradley, Jonathan N.

    1998-01-01

    A method and apparatus for embedding auxiliary information into the digital representation of host data created by a lossy compression technique and a method and apparatus for constructing auxiliary data from the correspondence between values in a digital key-pair table with integer index values existing in a representation of host data created by a lossy compression technique. The methods apply to data compressed with algorithms based on series expansion, quantization to a finite number of symbols, and entropy coding. Lossy compression methods represent the original data as ordered sequences of blocks containing integer indices having redundancy and uncertainty of value by one unit, allowing indices which are adjacent in value to be manipulated to encode auxiliary data. Also included is a method to improve the efficiency of lossy compression algorithms by embedding white noise into the integer indices. Lossy compression methods use loss-less compression to reduce to the final size the intermediate representation as indices. The efficiency of the loss-less compression, known also as entropy coding compression, is increased by manipulating the indices at the intermediate stage. Manipulation of the intermediate representation improves lossy compression performance by 1 to 10%.

  12. Rarity-weighted richness: a simple and reliable alternative to integer programming and heuristic algorithms for minimum set and maximum coverage problems in conservation planning.

    PubMed

    Albuquerque, Fabio; Beier, Paul

    2015-01-01

    Here we report that prioritizing sites in order of rarity-weighted richness (RWR) is a simple, reliable way to identify sites that represent all species in the fewest number of sites (minimum set problem) or to identify sites that represent the largest number of species within a given number of sites (maximum coverage problem). We compared the number of species represented in sites prioritized by RWR to numbers of species represented in sites prioritized by the Zonation software package for 11 datasets in which the size of individual planning units (sites) ranged from <1 ha to 2,500 km2. On average, RWR solutions were more efficient than Zonation solutions. Integer programming remains the only guaranteed way find an optimal solution, and heuristic algorithms remain superior for conservation prioritizations that consider compactness and multiple near-optimal solutions in addition to species representation. But because RWR can be implemented easily and quickly in R or a spreadsheet, it is an attractive alternative to integer programming or heuristic algorithms in some conservation prioritization contexts.

  13. Enhanced pid vs model predictive control applied to bldc motor

    NASA Astrophysics Data System (ADS)

    Gaya, M. S.; Muhammad, Auwal; Aliyu Abdulkadir, Rabiu; Salim, S. N. S.; Madugu, I. S.; Tijjani, Aminu; Aminu Yusuf, Lukman; Dauda Umar, Ibrahim; Khairi, M. T. M.

    2018-01-01

    BrushLess Direct Current (BLDC) motor is a multivariable and highly complex nonlinear system. Variation of internal parameter values with environment or reference signal increases the difficulty in controlling the BLDC effectively. Advanced control strategies (like model predictive control) often have to be integrated to satisfy the control desires. Enhancing or proper tuning of a conventional algorithm results in achieving the desired performance. This paper presents a performance comparison of Enhanced PID and Model Predictive Control (MPC) applied to brushless direct current motor. The simulation results demonstrated that the PSO-PID is slightly better than the PID and MPC in tracking the trajectory of the reference signal. The proposed scheme could be useful algorithms for the system.

  14. Elucidating PID Degradation Mechanisms and In Situ Dark I–V Monitoring for Modeling Degradation Rate in CdTe Thin-Film Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacke, Peter; Spataru, Sergiu; Johnston, Steve

    A progression of potential-induced degradation (PID) mechanisms are observed in CdTe modules, including shunting/junction degradation and two different manifestations of series resistance depending on the stress level and water ingress. The dark I-V method for in-situ characterization of Pmax based on superposition was adapted for the thin-film modules undergoing PID in view of the degradation mechanisms observed. An exponential model based on module temperature and relative humidity was fit to the PID rate for multiple stress levels in chamber tests and validated by predicting the observed degradation of the module type in the field.

  15. Data Publication Process for CMIP5 Data and the Role of PIDs within Federated Earth System Science Projects

    NASA Astrophysics Data System (ADS)

    Stockhause, M.; Höck, H.; Toussaint, F.; Weigel, T.; Lautenschlager, M.

    2012-12-01

    We present the publication process for the CMIP5 (Coupled Model Intercomparison Project Phase 5) data with special emphasis on the current role of identifiers and the potential future role of PIDs in such distributed technical infrastructures. The DataCite data publication with DOI assignment finalizes the 3 levels quality control procedure for CMIP5 data (Stockhause et al., 2012). WDCC utilizes the Assistant System Atarrabi to support the publication process. Atarrabi is a web-based workflow system for metadata reviews of data creators and Publication Agents (PAs). Within the quality checks for level 3 all available information in the different infrastructure components is cross-checked for consistency by the DataCite PA. This information includes: metadata on data, metadata in the long-term archive of the Publication Agency, quality information, and external metadata on model and simulation (CIM). For these consistency checks metadata related to the data publication has to be identified. The Data Reference Syntax (DRS) convention functions as global identifier for data. Since the DRS structures the data, hierarchically, it can be used to identify data collections like DataCite publication units, i.e. all data belonging to a CMIP5 simulation. Every technical component of the infrastructure uses DRS or maps to it, but there is no central repository storing DRS_ids. Thus they have to be mapped, occasionally. Additional local identifiers are used within the different technical infrastructure components. Identification of related pieces of information in their repositories is cumbersome and tricky for the PA. How could PIDs improve the situation? To establish a reliable distributed data and metadata infrastructure, PIDs for all objects are needed as well as relations between them. An ideal data publication scenario for federated community projects within Earth System Sciences, e.g. CMIP, would be: 1. Data creators at the modeling centers define their simulation, related metadata, and software, which are assigned PIDs. 2. During ESGF data publication the data entities are assigned PIDs with references to the PIDs of 1. Since we deal with different hierarchical levels, the definition of collections on these levels is advantageous. A possible implementation concept using Handles is described by Weigel et al. (2012). 3. Quality results are assigned PID(s) and a reference to the data. A quality PID is added as a reference to the data collection PID. 4. The PA accesses the PID on the data collection to get the data and all related information for cross-checking. The presented example of the technical infrastructure for the CMIP5 data distribution shows the importance of PIDs, especially as the data is distributed over multiple repositories world-wide and additional separate pieces of data related information are independently collected from the data. References: Stockhause, M., Höck, H., Toussaint, F., Lautenschlager, M. (2012): 'Quality assessment concept of the World Data Center for Climate and its application to CMIP5 data', Geosci. Model Dev. Discuss., 5, 781-802, doi:10.5194/gmdd-5-781-2012. Weigel, T., et al. (2012): 'Structural Elements in a Persistent Identifier Infrastructure and Resulting Benefits for the Earth Science Community', submitted to AGU 2012 Session IN009.

  16. Tunning PID controller using particle swarm optimization algorithm on automatic voltage regulator system

    NASA Astrophysics Data System (ADS)

    Aranza, M. F.; Kustija, J.; Trisno, B.; Hakim, D. L.

    2016-04-01

    PID Controller (Proportional Integral Derivative) was invented since 1910, but till today still is used in industries, even though there are many kind of modern controllers like fuzz controller and neural network controller are being developed. Performance of PID controller is depend on on Proportional Gain (Kp), Integral Gain (Ki) and Derivative Gain (Kd). These gains can be got by using method Ziegler-Nichols (ZN), gain-phase margin, Root Locus, Minimum Variance dan Gain Scheduling however these methods are not optimal to control systems that nonlinear and have high-orde, in addition, some methods relative hard. To solve those obstacles, particle swarm optimization (PSO) algorithm is proposed to get optimal Kp, Ki and Kd. PSO is proposed because PSO has convergent result and not require many iterations. On this research, PID controller is applied on AVR (Automatic Voltage Regulator). Based on result of analyzing transient, stability Root Locus and frequency response, performance of PID controller is better than Ziegler-Nichols.

  17. A Family Study of the DSM-5 Section III Personality Pathology Model Using the Personality Inventory for the DSM-5 (PID-5).

    PubMed

    Katz, Andrea C; Hee, Danelle; Hooker, Christine I; Shankman, Stewart A

    2017-10-03

    In Section III of the DSM-5, the American Psychiatric Association (APA) proposes a pathological personality trait model of personality disorders. The recommended assessment instrument is the Personality Inventory for the DSM-5 (PID-5), an empirically derived scale that assesses personality pathology along five domains and 25 facets. Although the PID-5 demonstrates strong convergent validity with other personality measures, no study has examined whether it identifies traits that run in families, another important step toward validating the DSM-5's dimensional model. Using a family study method, we investigated familial associations of PID-5 domain and facet scores in 195 families, examining associations between parents and offspring and across siblings. The Psychoticism, Antagonism, and Detachment domains showed significant familial aggregation, as did facets of Negative Affect and Disinhibition. Results are discussed in the context of personality pathology and family study methodology. The results also help validate the PID-5, given the familial nature of personality traits.

  18. Hierarchical Structure and Cross-Cultural Measurement Invariance of the Norwegian Version of the Personality Inventory for DSM-5.

    PubMed

    Thimm, Jens C; Jordan, Stian; Bach, Bo

    2017-01-01

    The Personality Inventory for DSM-5 (PID-5) was created to aid a trait-based diagnostic system for personality disorders (PDs) in the Diagnostic and Statistical Manual of Mental Disorders (5th ed. [DSM-5]; American Psychiatric Association, 2013a ). In this study, we aimed to evaluate the Norwegian version of the PID-5 by examining its score reliability, hierarchical structure, congruency with international findings, and cross-cultural measurement invariance with a matched U.S. For this purpose, 503 university students (76% females) were administered the PID-5. The Norwegian PID-5 showed good score reliability and structural validity from 1 to 5 factors. The 5-factor structure was generally congruent with international findings, and support for measurement invariance across the Norwegian and a matched U.S. sample was found. Conclusively, the results indicate that scores on the Norwegian PID-5 have sound psychometric properties, which are substantially comparable with the original U.S. version, supporting its use in a Norwegian population.

  19. Wireless Sensor Network Congestion Control Based on Standard Particle Swarm Optimization and Single Neuron PID

    PubMed Central

    Yang, Xiaoping; Chen, Xueying; Xia, Riting; Qian, Zhihong

    2018-01-01

    Aiming at the problem of network congestion caused by the large number of data transmissions in wireless routing nodes of wireless sensor network (WSN), this paper puts forward an algorithm based on standard particle swarm–neural PID congestion control (PNPID). Firstly, PID control theory was applied to the queue management of wireless sensor nodes. Then, the self-learning and self-organizing ability of neurons was used to achieve online adjustment of weights to adjust the proportion, integral and differential parameters of the PID controller. Finally, the standard particle swarm optimization to neural PID (NPID) algorithm of initial values of proportion, integral and differential parameters and neuron learning rates were used for online optimization. This paper describes experiments and simulations which show that the PNPID algorithm effectively stabilized queue length near the expected value. At the same time, network performance, such as throughput and packet loss rate, was greatly improved, which alleviated network congestion and improved network QoS. PMID:29671822

  20. Wireless Sensor Network Congestion Control Based on Standard Particle Swarm Optimization and Single Neuron PID.

    PubMed

    Yang, Xiaoping; Chen, Xueying; Xia, Riting; Qian, Zhihong

    2018-04-19

    Aiming at the problem of network congestion caused by the large number of data transmissions in wireless routing nodes of wireless sensor network (WSN), this paper puts forward an algorithm based on standard particle swarm⁻neural PID congestion control (PNPID). Firstly, PID control theory was applied to the queue management of wireless sensor nodes. Then, the self-learning and self-organizing ability of neurons was used to achieve online adjustment of weights to adjust the proportion, integral and differential parameters of the PID controller. Finally, the standard particle swarm optimization to neural PID (NPID) algorithm of initial values of proportion, integral and differential parameters and neuron learning rates were used for online optimization. This paper describes experiments and simulations which show that the PNPID algorithm effectively stabilized queue length near the expected value. At the same time, network performance, such as throughput and packet loss rate, was greatly improved, which alleviated network congestion and improved network QoS.

  1. Utilization of coincidence criteria in absolute length measurements by optical interferometry in vacuum and air

    NASA Astrophysics Data System (ADS)

    Schödel, R.

    2015-08-01

    Traceability of length measurements to the international system of units (SI) can be realized by using optical interferometry making use of well-known frequencies of monochromatic light sources mentioned in the Mise en Pratique for the realization of the metre. At some national metrology institutes, such as Physikalisch-Technische Bundesanstalt (PTB) in Germany, the absolute length of prismatic bodies (e.g. gauge blocks) is realized by so-called gauge-block interference comparators. At PTB, a number of such imaging phase-stepping interference comparators exist, including specialized vacuum interference comparators, each equipped with three highly stabilized laser light sources. The length of a material measure is expressed as a multiple of each wavelength. The large number of integer interference orders can be extracted by the method of exact fractions in which the coincidence of the lengths resulting from the different wavelengths is utilized as a criterion. The unambiguous extraction of the integer interference orders is an essential prerequisite for correct length measurements. This paper critically discusses coincidence criteria and their validity for three modes of absolute length measurements: 1) measurements under vacuum in which the wavelengths can be identified with the vacuum wavelengths, 2) measurements under air in which the air refractive index is obtained from environmental parameters using an empirical equation, and 3) measurements under air in which the air refractive index is obtained interferometrically by utilizing a vacuum cell placed along the measurement pathway. For case 3), which corresponds to PTB’s Kösters-Comparator for long gauge blocks, the unambiguous determination of integer interference orders related to the air refractive index could be improved by about a factor of ten when an ‘overall dispersion value,’ suggested in this paper, is used as coincidence criterion.

  2. Establishment of hydrochloric acid/lipopolysaccharide-induced pelvic inflammatory disease model.

    PubMed

    Oh, Yeonsu; Lee, Jaehun; Kim, Hyeon-Cheol; Hahn, Tae-Wook; Yoon, Byung-Il; Han, Jeong-Hee; Kwon, Yong-Soo; Park, Joung Jun; Koo, Deog-Bon; Rhee, Ki-Jong; Jung, Bae Dong

    2016-09-30

    Pelvic inflammatory disease (PID), which is one of the most problematic complications experienced by women with sexually transmitted diseases, frequently causes secondary infections after reproductive abnormalities in veterinary animals. Although the uterus is self-protective, it becomes fragile during periods or pregnancy. To investigate PID, bacteria or lipopolysaccharide (LPS) extracted from gram negative bacteria has been used to induce the disease in several animal models. However, when LPS is applied to the peritoneum, it often causes systemic sepsis leading to death and the PID was not consistently demonstrated. Hydrochloric acid (HCl) has been used to induce inflammation in the lungs and stomach but not tested for reproductive organs. In this study, we developed a PID model in mice by HCl and LPS sequential intracervical (i.c.) administration. The proinflammatory cytokines, interleukin (IL)-1β, IL-6 and tumor necrosis factor-α, were detected in the mouse uterus by western blot analysis and cytokine enzyme-linked immunosorbent assay after HCl (25 mg/kg) administration i.c. followed by four LPS (50 mg/kg) treatments. Moreover, mice exhibited increased infiltration of neutrophils in the endometrium and epithelial layer. These results suggest that ic co-administration of HCl and LPS induces PID in mice. This new model may provide a consistent and reproducible PID model for future research.

  3. Establishment of hydrochloric acid/lipopolysaccharide-induced pelvic inflammatory disease model

    PubMed Central

    Oh, Yeonsu; Lee, Jaehun; Kim, Hyeon-Cheol; Hahn, Tae-Wook; Yoon, Byung-Il; Han, Jeong-Hee; Kwon, Yong-Soo; Park, Joung Jun; Koo, Deog-Bon; Rhee, Ki-Jong

    2016-01-01

    Pelvic inflammatory disease (PID), which is one of the most problematic complications experienced by women with sexually transmitted diseases, frequently causes secondary infections after reproductive abnormalities in veterinary animals. Although the uterus is self-protective, it becomes fragile during periods or pregnancy. To investigate PID, bacteria or lipopolysaccharide (LPS) extracted from gram negative bacteria has been used to induce the disease in several animal models. However, when LPS is applied to the peritoneum, it often causes systemic sepsis leading to death and the PID was not consistently demonstrated. Hydrochloric acid (HCl) has been used to induce inflammation in the lungs and stomach but not tested for reproductive organs. In this study, we developed a PID model in mice by HCl and LPS sequential intracervical (i.c.) administration. The proinflammatory cytokines, interleukin (IL)-1β, IL-6 and tumor necrosis factor-α, were detected in the mouse uterus by western blot analysis and cytokine enzyme-linked immunosorbent assay after HCl (25 mg/kg) administration i.c. followed by four LPS (50 mg/kg) treatments. Moreover, mice exhibited increased infiltration of neutrophils in the endometrium and epithelial layer. These results suggest that ic co-administration of HCl and LPS induces PID in mice. This new model may provide a consistent and reproducible PID model for future research. PMID:26726020

  4. Simulated Annealing-based Optimal Proportional-Integral-Derivative (PID) Controller Design: A Case Study on Nonlinear Quadcopter Dynamics

    NASA Astrophysics Data System (ADS)

    Nemirsky, Kristofer Kevin

    In this thesis, the history and evolution of rotor aircraft with simulated annealing-based PID application were reviewed and quadcopter dynamics are presented. The dynamics of a quadcopter were then modeled, analyzed, and linearized. A cascaded loop architecture with PID controllers was used to stabilize the plant dynamics, which was improved upon through the application of simulated annealing (SA). A Simulink model was developed to test the controllers and verify the functionality of the proposed control system design. In addition, the data that the Simulink model provided were compared with flight data to present the validity of derived dynamics as a proper mathematical model representing the true dynamics of the quadcopter system. Then, the SA-based global optimization procedure was applied to obtain optimized PID parameters. It was observed that the tuned gains through the SA algorithm produced a better performing PID controller than the original manually tuned one. Next, we investigated the uncertain dynamics of the quadcopter setup. After adding uncertainty to the gyroscopic effects associated with pitch-and-roll rate dynamics, the controllers were shown to be robust against the added uncertainty. A discussion follows to summarize SA-based algorithm PID controller design and performance outcomes. Lastly, future work on SA application on multi-input-multi-output (MIMO) systems is briefly discussed.

  5. Regulation of flow through a T-Shaped open cavity by temperature dependent P, PI, and PID controllers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saha, Sourav, E-mail: ssaha09@me.buet.ac.bd; Mojumder, Satyajit, E-mail: satyajit@me.buet.ac.bd; Saha, Sumon, E-mail: sumonsaha@me.buet.ac.bd

    P (proportional), PI (proportional-integral), and PID (proportional-integral-derivative) controllers are popular means of controlling industrial processes. Due to superior response, accuracy, and stable performance, PID controllers are mostly used in control systems. This paper presents a mathematical model and subsequent response analysis regarding regulation of flow in mixed convection through a T-shaped open cavity by temperature dependent controllers. The T-shaped cavity has cold top and hot bottom walls, while air is flowing through the inlet at surrounding temperature. The inflow is regulated by a controlled gate which operates according to the signal received from the controller. Values of proportional gain (k{submore » p}), integral gain (k{sub i}), and derivative gain (k{sub d}) are varied to obtain the desired system response and to ensure a stable system with fastest response. At first, only P controller is used and eventually PI and finally PID control scheme is applied for controller tuning. Tuning of different controllers (P, PI, and PID) are carried out systematically based on the reference temperature which is continuously monitored at a certain location inside the cavity. It is found that PID controller performs better than P or PI controller.« less

  6. Updated French guidelines for diagnosis and management of pelvic inflammatory disease.

    PubMed

    Brun, Jean-Luc; Graesslin, Olivier; Fauconnier, Arnaud; Verdon, Renaud; Agostini, Aubert; Bourret, Antoine; Derniaux, Emilie; Garbin, Olivier; Huchon, Cyrille; Lamy, Catherine; Quentin, Roland; Judlin, Philippe

    2016-08-01

    Pelvic inflammatory disease (PID) is commonly encountered in clinical practice. To provide up-to-date guidelines on management of PID. An initial search of the Cochrane database, PubMed, and Embase was performed using keywords related to PID to identify reports in any language published between January 1990 and January 2012, with an update in May 2015. All identified reports relevant to the areas of focus were included. A level of evidence based on the quality of the data available was applied for each area of focus and used for the guidelines. PID must be suspected when spontaneous pelvic pain is associated with induced adnexal or uterine pain (grade C). Pelvic ultrasonography is necessary to exclude tubo-ovarian abscess (grade B). Microbiological diagnosis requires vaginal and endocervical sampling for molecular and bacteriological analysis (grade B). First-line treatment for uncomplicated PID combines ofloxacin and metronidazole for 14days (grade B). Treatment of tubo-ovarian abscess is based on drainage if the collection measures more than 3cm (grade B), with combined ceftriaxone, metronidazole, and doxycycline for 14-21days. Current management of PID requires easily reproducible investigations and treatment, and thus can be applied worldwide. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Screening and treating Chlamydia trachomatis genital infection to prevent pelvic inflammatory disease: interpretation of findings from randomized controlled trials.

    PubMed

    Gottlieb, Sami L; Xu, Fujie; Brunham, Robert C

    2013-02-01

    We critically reviewed randomized controlled trials evaluating chlamydia screening to prevent pelvic inflammatory disease (PID) and explored factors affecting interpretation and translation of trial data into public health prevention. Taken together, data from these trials offer evidence that chlamydia screening and treatment is an important and useful intervention to reduce the risk of PID among young women. However, the magnitude of benefit to be expected from screening may have been overestimated based on the earliest trials. It is likely that chlamydia screening programs have contributed to declines in PID incidence through shortening prevalent infections, although the magnitude of their contribution remains unclear. Program factors such as screening coverage as well as natural history factors such as risk of PID after repeat chlamydia infection can be important in determining the impact of chlamydia screening on PID incidence in a population. Uptake of chlamydia screening is currently suboptimal, and expansion of screening among young, sexually active women remains a priority. To reduce transmission and repeat infections, implementation of efficient strategies to treat partners of infected women is also essential. Results of ongoing randomized evaluations of the effect of screening on community-wide chlamydia prevalence and PID will also be valuable.

  8. Persistent Identifiers as Boundary Objects

    NASA Astrophysics Data System (ADS)

    Parsons, M. A.; Fox, P. A.

    2017-12-01

    In 1989, Leigh Star and Jim Griesemer defined the seminal concept of `boundary objects'. These `objects' are what Latour calls `immutable mobiles' that enable communication and collaboration across difference by helping meaning to be understood in different contexts. As Star notes, they are a sort of arrangement that allow different groups to work together without (a priori) consensus. Part of the idea is to recognize and allow for the `interpretive flexibility' that is central to much of the `constructivist' approach in the sociology of science. Persistent Identifiers (PIDs) can clearly act as boundary objects, but people do not usually assume that they enable interpretive flexibility. After all, they are meant to be unambiguous, machine-interpretable identifiers of defined artifacts. In this paper, we argue that PIDs can fill at least two roles: 1) That of the standardized form, where there is strong agreement on what is being represented and how and 2) that of the idealized type, a more conceptual concept that allows many different representations. We further argue that these seemingly abstract conceptions actually help us implement PIDs more effectively to link data, publications, various other artifacts, and especially people. Considering PIDs as boundary objects can help us address issues such as what level of granularity is necessary for PIDs, what metadata should be directly associated with PIDs, and what purpose is the PID serving (reference, provenance, credit, etc.). In short, sociological theory can improve data sharing standards and their implementation in a way that enables broad interdisciplinary data sharing and reuse. We will illustrate this with several specific examples of Earth science data.

  9. Risk of pelvic inflammatory disease after Chlamydia infection in a prospective cohort of sex workers.

    PubMed

    Davies, Bethan; Turner, Katy; Ward, Helen

    2013-03-01

    There is uncertainty in the risk of pelvic inflammatory disease (PID) after chlamydia infection. We analyzed a prospective cohort of sex workers recruited in London between 1985 and 1993 to estimate the risk of PID after a diagnosed case of chlamydia. Chlamydia and gonorrhea were defined as "recent" if they occurred during the most recent 6 months of follow-up or "previous" if they were more than 6 months ago, were the second infection during follow-up, or occurred before the study. Pelvic inflammatory disease was diagnosed using clinical criteria. We used Cox proportional hazards regression to estimate the association between chlamydia and PID controlled for gonorrhea. Three hundred seven women contributed 401.2 person-years of follow-up. The rate of PID in women with recent chlamydia was 27.4 per 100 person-years compared with 11.2 in those without recent chlamydia. Recent and previous chlamydia significantly increased the risk of PID; this association persisted but was no longer significant after controlling for age and history of gonorrhea: recent chlamydia (adjusted hazard ratio [aHR], 2.0; 95% confidence interval [CI], 0.7-5.5), previous chlamydia (aHR, 1.8; 95% CI, 1.0-3.5), previous gonorrhea (aHR, 2.3; 95% CI, 1.1-4.6), and age (HR, 0.9; 95% CI, 0.9-1.0). Women with recent or previous chlamydia are at increased risk for PID. However, this association may be explained by previous exposure to gonorrhea, which was found to increase the risk of PID after a future chlamydia infection.

  10. [The role of intrauterine contraceptive devices in the development of inflammatory processes in the small pelvis].

    PubMed

    Batar, I

    1986-08-10

    The incidence of pelvic inflammatory disease (PID) attributable to IUD use has been increasing, especially after the removal of the Dalkon shield from the market, but this relationship has not been settled conclusively. In recent decades PID included a variety of infections, but lately the definition of PID has meant acute ascending infections of the female genital tract. Its most common risk factors include promiscuity of IUD use, although this can be reduced to one fourth by regular checkups and proper hygiene. The frequency of PID is estimated at 2-5% of IUD users. Microorganisms contributing to PID include Neisseria gonorrhoeae, Chlamydia trachomatis, Mycoplasma hominis, Escherichia coli, Proteus, Staphylococcus epidermis, Haemophilus influenzae, Bacteroides, Peptococcus, Peptostreptococcus, Clostridium, and Actinomyces israelii, The differentiation of actinomycosis (AC) and pseudoactinomycosis (PAC) is well advised. The potential of IUD use in increasing the risk of AIDS should not be discounted. The clinical picture of PID is varied, it can be mild requiring conservative drug therapy; with medium severity requiring removal of the IUD and drug therapy; severe necessitating removal, antibiotics and sulfonamide treatment and laparotomy; and very severe with potentially fatal generalized sepsis. In addition to antibiotics, e.g., penicillin, treatment can include the so called catastrophy combination of Mandokef- Metronidazol-Gentamycin. An analysis of the data of 8536 IUD fittings in Debrecen, Hungary showed 1.4% removals due to PID after 4 years, 694 patients (8.1%) had lower abdominal pain 73 of which (0.9%) had palpable resistance, and suppuration occurred in only 30 cases (0.4%). Treatment included Semicillin or Tetran, or removal of the IUD, and even surgery if no improvement resulted. Prevention of PID include elimination of risk factors, the careful selection of IUD users, regular checkups, the use of copper (Cu) T device, and strict adherence to professional standards.

  11. Integers as Transformations.

    ERIC Educational Resources Information Center

    Thompson, Patrick W.; Dreyfus, Tommy

    1988-01-01

    Investigates whether elementary school students can construct operations of thought for integers and integer addition crucial for understanding elementary algebra. Two sixth graders were taught using a computer. Results included both students being able to construct mental operations for negating arbitrary integers and determining sign and…

  12. Paradeisos: A perfect hashing algorithm for many-body eigenvalue problems

    DOE PAGES

    Jia, C. J.; Wang, Y.; Mendl, C. B.; ...

    2017-12-02

    Here, we describe an essentially perfect hashing algorithm for calculating the position of an element in an ordered list, appropriate for the construction and manipulation of many-body Hamiltonian, sparse matrices. Each element of the list corresponds to an integer value whose binary representation reflects the occupation of single-particle basis states for each element in the many-body Hilbert space. The algorithm replaces conventional methods, such as binary search, for locating the elements of the ordered list, eliminating the need to store the integer representation for each element, without increasing the computational complexity. Combined with the “checkerboard” decomposition of the Hamiltonian matrixmore » for distribution over parallel computing environments, this leads to a substantial savings in aggregate memory. While the algorithm can be applied broadly to many-body, correlated problems, we demonstrate its utility in reducing total memory consumption for a series of fermionic single-band Hubbard model calculations on small clusters with progressively larger Hilbert space dimension.« less

  13. Method and apparatus for recirculation with control of synchrotron radiation

    DOEpatents

    Douglas, David R.; Tennant, Christopher

    2016-08-02

    A method for controlling beam quality degradation from ISR and CSR and stabilizing the microbunching instability (.mu.BI) in a high brightness electron beam. The method includes providing a super-periodic second order achromat line with each super period being individually linearly achromatic and isochronous, setting individual superperiod tunes to rational fractions of an integer (such as 4.sup.th or 6.sup.th integers), setting individual bend angles to be as small as practical to reduce driving terms due to dispersion and dispersive angle, and setting bend radii as large enough to suppress ISR but not negatively affect the radial dependence of CSR. The method includes setting the structure of the individual superperiods to minimize bend plane beam envelope values in the dipoles to reduce betatron response to a CSR event at a dispersed location, increasing beam angular divergence, and creating dispersion nodes in the dipoles to similarly reduce response to CSR events, and limit R.sub.56 modulation in order to mitigate .mu.BI.

  14. Paradeisos: A perfect hashing algorithm for many-body eigenvalue problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jia, C. J.; Wang, Y.; Mendl, C. B.

    Here, we describe an essentially perfect hashing algorithm for calculating the position of an element in an ordered list, appropriate for the construction and manipulation of many-body Hamiltonian, sparse matrices. Each element of the list corresponds to an integer value whose binary representation reflects the occupation of single-particle basis states for each element in the many-body Hilbert space. The algorithm replaces conventional methods, such as binary search, for locating the elements of the ordered list, eliminating the need to store the integer representation for each element, without increasing the computational complexity. Combined with the “checkerboard” decomposition of the Hamiltonian matrixmore » for distribution over parallel computing environments, this leads to a substantial savings in aggregate memory. While the algorithm can be applied broadly to many-body, correlated problems, we demonstrate its utility in reducing total memory consumption for a series of fermionic single-band Hubbard model calculations on small clusters with progressively larger Hilbert space dimension.« less

  15. Pelvic inflammatory disease (PID)

    MedlinePlus

    ... Names PID; Oophoritis; Salpingitis; Salpingo - oophoritis; Salpingo - peritonitis Images Pelvic laparoscopy Female reproductive anatomy Endometritis Uterus References McKinzie J. Sexually transmitted diseases. In: Walls RM, Hockberger RS, ...

  16. Temperature dependence on plasma-induced damage and chemical reactions in GaN etching processes using chlorine plasma

    NASA Astrophysics Data System (ADS)

    Liu, Zecheng; Ishikawa, Kenji; Imamura, Masato; Tsutsumi, Takayoshi; Kondo, Hiroki; Oda, Osamu; Sekine, Makoto; Hori, Masaru

    2018-06-01

    Plasma-induced damage (PID) on GaN was optimally reduced by high-temperature chlorine plasma etching. Energetic ion bombardments primarily induced PID involving stoichiometry, surface roughness, and photoluminescence (PL) degradation. Chemical reactions under ultraviolet (UV) irradiation and chlorine radical exposure at temperatures higher than 400 °C can be controlled by taking into account the synergism of simultaneous photon and radical irradiations to effectively reduce PID.

  17. Adaptive PID formation control of nonholonomic robots without leader's velocity information.

    PubMed

    Shen, Dongbin; Sun, Weijie; Sun, Zhendong

    2014-03-01

    This paper proposes an adaptive proportional integral derivative (PID) algorithm to solve a formation control problem in the leader-follower framework where the leader robot's velocities are unknown for the follower robots. The main idea is first to design some proper ideal control law for the formation system to obtain a required performance, and then to propose the adaptive PID methodology to approach the ideal controller. As a result, the formation is achieved with much more enhanced robust formation performance. The stability of the closed-loop system is theoretically proved by Lyapunov method. Both numerical simulations and physical vehicle experiments are presented to verify the effectiveness of the proposed adaptive PID algorithm. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  18. On Reductions of the Hirota-Miwa Equation

    NASA Astrophysics Data System (ADS)

    Hone, Andrew N. W.; Kouloukas, Theodoros E.; Ward, Chloe

    2017-07-01

    The Hirota-Miwa equation (also known as the discrete KP equation, or the octahedron recurrence) is a bilinear partial difference equation in three independent variables. It is integrable in the sense that it arises as the compatibility condition of a linear system (Lax pair). The Hirota-Miwa equation has infinitely many reductions of plane wave type (including a quadratic exponential gauge transformation), defined by a triple of integers or half-integers, which produce bilinear ordinary difference equations of Somos/Gale-Robinson type. Here it is explained how to obtain Lax pairs and presymplectic structures for these reductions, in order to demonstrate Liouville integrability of some associated maps, certain of which are related to reductions of discrete Toda and discrete KdV equations.

  19. PLAN FOR BETTER EDUCATION THROUGH INTEGATION.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY.

    IN ORDER TO PREPARE PUPILS TO PARTICIPATE FULLY, REGARDLESS OF ENVIRONMENTAL HANDICAP, IN ECONOMIC, SOCIAL, AND POLITICAL LIFE, SCHOOLS SHOULD MAKE IMPROVEMENTS IN THE PROBLEM OF DESEGREGATION. SPECIFIC PLANS UNDERTAKEN BY NEW YORK CITY REQUIRED THE STUDY OF CERTAIN ASPECTS OF EDUCATION--ELEMENTARY SCHOOL COMMUNITY ZONING, JUNIOR HIGH SCHOOL…

  20. Prevalence and risk factors of symptoms of pelvic inflammatory disease in a rural community of Jamshoro, Sindh, Pakistan.

    PubMed

    Bhurt, A W; Fikree, F F; Bhurt, A M; Channa, G Z; Soomro, R A; Bhurt, N

    1999-08-01

    (1). To estimate the prevalence of symptoms of pelvic inflammatory disease (PID) in rural Jamshoro, Sindh, (2). To assess specific social and biological risk factors of symptoms of PID. Trained females conducted the interviews using a pre-tested Sindhi questionnaire during a cross-sectional survey carried out in 8 villages of rural Jamshoro, Sindh. Women reporting either lower abdominal pain or vaginal discharge with continuous or intermittent fever during the 6 months prior to interview, were classified as having PID symptoms. We approached 753 ever-married women and successfully interviewed 738 (98%) from July-September 1997. Sixty-five women (9%) had symptoms consistent with PID, and 156 (24%) reported ever using a modern contraceptive. Symptomatic women were 3.6 times more likely to have ever used IUCD/tubal ligation (95% CI, 1.9-6.9), 1.8 times more likely to have married at earlier age (< 15) (95% CI, 1.1-3), and 3 times more likely to be housewives by occupation (95% CI, 10-8.4) as compared to women who did not have PID symptoms. Symptoms of PID among tubal ligation/IUCD users may reflect existence of unhygienic conditions during application of procedure, delay in replacement of IUCD and mismatching in the size of IUCD with uterus. The quality of life is affected in women with PID symptoms and may have serious consequences like infertility. These symptoms need thorough evaluation/investigation to gauge the magnitude and nature of the problem and to guide intervention, effective promotion of women's socio-economic status, health education regarding counselling for delaying age at marriage and hygienic/safe use of family planning methods.

  1. Control of force during rapid visuomotor force-matching tasks can be described by discrete time PID control algorithms.

    PubMed

    Dideriksen, Jakob Lund; Feeney, Daniel F; Almuklass, Awad M; Enoka, Roger M

    2017-08-01

    Force trajectories during isometric force-matching tasks involving isometric contractions vary substantially across individuals. In this study, we investigated if this variability can be explained by discrete time proportional, integral, derivative (PID) control algorithms with varying model parameters. To this end, we analyzed the pinch force trajectories of 24 subjects performing two rapid force-matching tasks with visual feedback. Both tasks involved isometric contractions to a target force of 10% maximal voluntary contraction. One task involved a single action (pinch) and the other required a double action (concurrent pinch and wrist extension). 50,000 force trajectories were simulated with a computational neuromuscular model whose input was determined by a PID controller with different PID gains and frequencies at which the controller adjusted muscle commands. The goal was to find the best match between each experimental force trajectory and all simulated trajectories. It was possible to identify one realization of the PID controller that matched the experimental force produced during each task for most subjects (average index of similarity: 0.87 ± 0.12; 1 = perfect similarity). The similarities for both tasks were significantly greater than that would be expected by chance (single action: p = 0.01; double action: p = 0.04). Furthermore, the identified control frequencies in the simulated PID controller with the greatest similarities decreased as task difficulty increased (single action: 4.0 ± 1.8 Hz; double action: 3.1 ± 1.3 Hz). Overall, the results indicate that discrete time PID controllers are realistic models for the neural control of force in rapid force-matching tasks involving isometric contractions.

  2. Place of laparoscopy in pelvic inflammatory disease.

    PubMed

    Krishna, U R; Sheth, S S; Motashaw, N D

    1979-06-01

    577 laparoscopic examinations were performed in women presenting with sterility, chronic abdominal pain, primary or secondary amenorrhea, and irregular menstrual periods. 125 cases of chronic pelvic inflammatory disease (PID) of both the tuberculous and nonspecific varieties were detected through this procedure. 59 of the 125 cases were diagnosed as tuberculous. Investigations prior to laparoscopy had yielded significant results in only 12 cases. 87 of the 125 cases had no abnormal clinical findings, and only 18 of the 37 tubo-ovarian masses were diagnosed by bimanual examination. These results indicate that laparoscopy is an invaluable tool for the diagnosis of PID. It can reveal peritubal adhesions, tubercles on the tubes, small tubo-ovarian masses, and hydrosalpinx cases that cannot be detected clinically. It is considered a more suitable tool than culdoscopy, which less frequently notes adhesions to the fallopian tubes and pathological conditions in the upper pelvis. Laparoscopy can play an especially valuable role in India as a prelude to tuboplasty, given the high incidence of pelvic tuberculosis. Of the 316 cases of primary sterility examined in this study, 51 had genital tuberculosis and 39 had nonspecific PID. Laparoscopy can also be useful in disproving cases wrongly labelled as chronic pelvic disease. 15 women in this study who reported chronic lower abdominal pain had normal findings, and only 13 cases of PID were confirmed among the 33 cases preoperatively diagnosed as PID. A significant number of PID cases are attributed to operative procedures such as hysterosalpingography and ventrisuspension that are repeated unnecessarily and without proper sepsis. Thus, the possibility of a flare-up of infection during laparoscopy, especially due to hydroperturbation, should be considered. Women in this study who were found to have PID were given postoperative antibiotics. No significant postoperative complications were observed.

  3. Mitigation of PID in commercial PV modules using current interruption method

    NASA Astrophysics Data System (ADS)

    Bora, Birinchi; Oh, Jaewon; Tatapudi, Sai; Sastry, Oruganty S.; Kumar, Rajesh; Prasad, Basudev; Tamizhmani, Govindasamy

    2017-08-01

    Potential-induced degradation (PID) is known to have a very severe effect on the reliability of PV modules. PID is caused due to the leakage of current from the cell circuit to the grounded frame under humid conditions of high voltage photovoltaic (PV) systems. There are multiple paths for the current leakage. The most dominant leakage path is from the cell to the frame through encapsulant, glass bulk and glass surface. This dominant path can be prevented by interrupting the electrical conductivity at the glass surface. In our previous works related to this topic, we demonstrated the effectiveness of glass surface conductivity interruption technique using one-cell PV coupons. In this work, we demonstrate the effectiveness of this technique using a full size commercial module susceptible to PID. The interruption of surface conductivity of the commercial module was achieved by attaching a narrow, thin flexible glass strips, from Corning, called Willow Glass on the glass surface along the inner edges of the frame. The flexible glass strip was attached to the module glass surface by heating the glass strip with an ionomer adhesive underneath using a handheld heat gun. The PID stress test was performed at 60°C and 85% RH for 96 hours at -600 V. Pre- and post-PID characterizations including I-V and electroluminescence were carried out to determine the performance loss and affected cell areas. This work demonstrates that the PID issue can be effectively addressed by using this current interruption technique. An important benefit of this approach is that this interruption technique can be applied after manufacturing the modules and after installing the modules in the field as well.

  4. Frequency of laboratory measurement and hyperkalaemia in hospitalised patients using serum potassium concentration increasing drugs.

    PubMed

    Uijtendaal, Esther V; Zwart-van Rijkom, Jeannette E F; van Solinge, Wouter W; Egberts, Toine C G

    2011-09-01

    Although, drug-drug interactions (DDIs) between potassium-increasing drugs (PIDs) are known risk factors for developing hyperkalaemia, not much is known about their risk and management strategies during hospitalisation. This study examines the frequency of serum potassium measurements and hyperkalaemia in hospitalised patients, based on the use of one or more PIDs, and the determinants thereof. Adult patients hospitalised in the University Medical Centre Utrecht between 2006 and 2008 were included in this cross-sectional study. The frequency of serum potassium measurements and of hyperkalaemia were compared between patients using only one PID at a time (monotherapy group) and patients using two or more PIDs concomitantly (interaction group). The determinants studied were renal failure, diabetes mellitus, use of diuretics, type of DDI, start of the PIDs within the hospital versus continued home medication and medical speciality. Serum potassium was measured more frequently in the interaction group than in the monotherapy group [67 vs. 56%; relative risk (RR) 1.19, 95% confidence interval (CI) 1.14-1.24] and the risk of hyperkalaemia was also increased in the interaction group (9.9 vs. 5.9%, RR 1.7, 95% CI 1.3-2.1). The combination of potassium-sparing diuretics plus a potassium supplement, start of the PID within the hospital and hospitalisation in non-internal medicine departments was associated with higher relative risk estimates for hyperkalaemia. Among our patient cohort, even when physicians received a direct pop-up to monitor serum potassium levels when prescribing two PIDs concomitantly, serum potassium levels were not measured in 33% of patients, and 10% of patients developed hyperkalaemia. Improved management strategies and/or clinical decision-support systems are needed to decrease the frequency of hyperkalaemia following DDIs.

  5. Neural Network-Based Self-Tuning PID Control for Underwater Vehicles

    PubMed Central

    Hernández-Alvarado, Rodrigo; García-Valdovinos, Luis Govinda; Salgado-Jiménez, Tomás; Gómez-Espinosa, Alfonso; Fonseca-Navarro, Fernando

    2016-01-01

    For decades, PID (Proportional + Integral + Derivative)-like controllers have been successfully used in academia and industry for many kinds of plants. This is thanks to its simplicity and suitable performance in linear or linearized plants, and under certain conditions, in nonlinear ones. A number of PID controller gains tuning approaches have been proposed in the literature in the last decades; most of them off-line techniques. However, in those cases wherein plants are subject to continuous parametric changes or external disturbances, online gains tuning is a desirable choice. This is the case of modular underwater ROVs (Remotely Operated Vehicles) where parameters (weight, buoyancy, added mass, among others) change according to the tool it is fitted with. In practice, some amount of time is dedicated to tune the PID gains of a ROV. Once the best set of gains has been achieved the ROV is ready to work. However, when the vehicle changes its tool or it is subject to ocean currents, its performance deteriorates since the fixed set of gains is no longer valid for the new conditions. Thus, an online PID gains tuning algorithm should be implemented to overcome this problem. In this paper, an auto-tune PID-like controller based on Neural Networks (NN) is proposed. The NN plays the role of automatically estimating the suitable set of PID gains that achieves stability of the system. The NN adjusts online the controller gains that attain the smaller position tracking error. Simulation results are given considering an underactuated 6 DOF (degrees of freedom) underwater ROV. Real time experiments on an underactuated mini ROV are conducted to show the effectiveness of the proposed scheme. PMID:27608018

  6. Neural Network-Based Self-Tuning PID Control for Underwater Vehicles.

    PubMed

    Hernández-Alvarado, Rodrigo; García-Valdovinos, Luis Govinda; Salgado-Jiménez, Tomás; Gómez-Espinosa, Alfonso; Fonseca-Navarro, Fernando

    2016-09-05

    For decades, PID (Proportional + Integral + Derivative)-like controllers have been successfully used in academia and industry for many kinds of plants. This is thanks to its simplicity and suitable performance in linear or linearized plants, and under certain conditions, in nonlinear ones. A number of PID controller gains tuning approaches have been proposed in the literature in the last decades; most of them off-line techniques. However, in those cases wherein plants are subject to continuous parametric changes or external disturbances, online gains tuning is a desirable choice. This is the case of modular underwater ROVs (Remotely Operated Vehicles) where parameters (weight, buoyancy, added mass, among others) change according to the tool it is fitted with. In practice, some amount of time is dedicated to tune the PID gains of a ROV. Once the best set of gains has been achieved the ROV is ready to work. However, when the vehicle changes its tool or it is subject to ocean currents, its performance deteriorates since the fixed set of gains is no longer valid for the new conditions. Thus, an online PID gains tuning algorithm should be implemented to overcome this problem. In this paper, an auto-tune PID-like controller based on Neural Networks (NN) is proposed. The NN plays the role of automatically estimating the suitable set of PID gains that achieves stability of the system. The NN adjusts online the controller gains that attain the smaller position tracking error. Simulation results are given considering an underactuated 6 DOF (degrees of freedom) underwater ROV. Real time experiments on an underactuated mini ROV are conducted to show the effectiveness of the proposed scheme.

  7. Primary Immunodeficiency Diseases in Oman: 10-Year Experience in a Tertiary Care Hospital.

    PubMed

    Al-Tamemi, Salem; Naseem, Shafiq Ur Rehman; Al-Siyabi, Nabila; El-Nour, Ibtisam; Al-Rawas, Abdulhakim; Dennison, David

    2016-11-01

    Primary immunodeficiency (PID) diseases are rare, complex medical disorders that often are overlooked in clinical settings. There are emerging reports of PID from Middle Eastern populations. This study describes the features of PID patients in a tertiary care setting in Oman and compares them with regional and worldwide reports. Sultan Qaboos University Hospital (SQUH) is an academic tertiary care-level hospital for specialized healthcare, including PID patients. At the time of diagnosis, patients' sociodemographics, clinical features, laboratory investigations, and management were entered in electronic form. This study included patients seen between August 2005 and July 2015. One hundred forty patients were registered with a minimum estimated population prevalence of 7.0/100,000. The male/female ratio was 1.6:1, the median age of onset of symptoms was 8 months, and diagnosis was 21 months with a delay of 13 months. Family history was positive in 44 %, consanguinity was present in 76 %, death of a previous sibling was present in 36 %, and there was an overall mortality in 18 %, with an 85 % probability of survival 10 years following diagnosis. The most common type of immunodeficiency was phagocytic disorders (35.0 %), followed by predominantly antibody disorders (20.7 %), combined immunodeficiency (17.8 %), other well-defined PID syndromes (15.0 %), immune dysregulation syndromes (3.5 %), complement deficiencies (3.5 %), and unclassified immunodeficiency (4.2 %). The commonest presenting infection was pneumonia (47.1 %). PID is not a rare condition in Oman. The prevalence is in concordance with reports from the region but higher than in Western populations. The findings of the current study would help to improve the awareness and management of, and policy making for PID.

  8. Rapid Flow cytometric prenatal diagnosis of primary immunodeficiency (PID) disorders.

    PubMed

    Mishra, Anju; Gupta, Maya; Dalvi, Aparna; Ghosh, Kanjaksha; Madkaikar, Manisha

    2014-04-01

    Primary Immunodeficiency diseases (PID) are a heterogeneous group of inherited disorders of immune system. Immunophenotypic evaluation of PIDs using flowcytometry provides important clues for diagnosis of these disorders, though confirmation requires identification of underlying molecular defects. Prenatal diagnosis (PND) forms an important component of management in families affected with severe PID. However, molecular diagnostic facilities for each of these diseases are not available and may not be possible to perform in all cases. In such scenario we opted for phenotypic prenatal diagnosis by cordocentesis for families with index case having immunophenotypically well characterized PID. Normal reference ranges of lymphocyte subsets, CD 18/CD11 integrins on leukocytes, MHC class II expression and oxidative burst activity of fetal neutrophils at 18 weeks of gestation were previously established on 30 cord blood samples. PND was performed in 13 families with PIDs. Maternal contamination was ruled out by VNTR analysis. Out of 13 fetuses, nine were found to be unaffected (three cases with leukocyte adhesion deficiency (LAD-I), four cases with severe combined immunodeficiency diseases (SCID), one with X-linked agammaglobulinemia (XLA), and one with chronic granulomatous disease (CGD)] and three were found to be affected (one with T-B+NK-SCID, one with MHC class II deficiency and one with LAD-I). Diagnosis was confirmed by testing the cord blood samples after delivery and further follow-up of the children. In one family diagnosis could not be offered due to maternal contamination. No procedure related complications were observed. Flowcytometry offers rapid and sensitive method for prenatal diagnosis and genetic counseling for selected phenotypically well characterized PID in cases where molecular diagnostic facilities are not available.

  9. Sample size considerations using mathematical models: an example with Chlamydia trachomatis infection and its sequelae pelvic inflammatory disease.

    PubMed

    Herzog, Sereina A; Low, Nicola; Berghold, Andrea

    2015-06-19

    The success of an intervention to prevent the complications of an infection is influenced by the natural history of the infection. Assumptions about the temporal relationship between infection and the development of sequelae can affect the predicted effect size of an intervention and the sample size calculation. This study investigates how a mathematical model can be used to inform sample size calculations for a randomised controlled trial (RCT) using the example of Chlamydia trachomatis infection and pelvic inflammatory disease (PID). We used a compartmental model to imitate the structure of a published RCT. We considered three different processes for the timing of PID development, in relation to the initial C. trachomatis infection: immediate, constant throughout, or at the end of the infectious period. For each process we assumed that, of all women infected, the same fraction would develop PID in the absence of an intervention. We examined two sets of assumptions used to calculate the sample size in a published RCT that investigated the effect of chlamydia screening on PID incidence. We also investigated the influence of the natural history parameters of chlamydia on the required sample size. The assumed event rates and effect sizes used for the sample size calculation implicitly determined the temporal relationship between chlamydia infection and PID in the model. Even small changes in the assumed PID incidence and relative risk (RR) led to considerable differences in the hypothesised mechanism of PID development. The RR and the sample size needed per group also depend on the natural history parameters of chlamydia. Mathematical modelling helps to understand the temporal relationship between an infection and its sequelae and can show how uncertainties about natural history parameters affect sample size calculations when planning a RCT.

  10. Physiologic Inter-eye Differences in Monkey Optic Nerve Head Architecture and Their Relation to Changes in Early Experimental Glaucoma

    PubMed Central

    Yang, Hongli; Downs, J. Crawford; Burgoyne, Claude F.

    2009-01-01

    Purpose To characterize physiologic inter-eye differences in optic nerve head (ONH) architecture within six normal rhesus monkeys and compare them to inter-eye differences within three previously-reported cynomolgus monkeys with early experimental glaucoma (EEG). Methods Trephinated ONH and peripapillary sclera from both eyes of six normal monkeys were serial sectioned, 3D reconstructed, 3D delineated and parameterized. For each normal animal, and each parameter, physiologic inter-eye difference (PID) was calculated (both overall and regionally) by converting all OS data to OD configuration and subtracting the OS from the OD value and Physiologic Inter-eye Percent Difference (PIPD) was calculated as the PID divided by the measurement mean of the two eyes. For each EEG monkey, inter-eye (EEG minus normal) differences and percent differences for each parameter overall and regionally were compared to the PID and PIPD Maximums. Results For all parameters the PID Maximums were relatively small overall. Compared to overall PID maximums, overall inter-eye differences in EEG monkeys were greatest for laminar deformation and thickening, posterior scleral canal enlargement, cupping and prelaminar neural tissue thickening. Compared to the regional PID Maximums, the lamina cribrosa was posteriorly deformed centrally, inferiorly, inferonasally and superiorly and was thickened centrally. The prelaminar neural tissues were thickened inferiorly, inferonasally and superiorly. Conclusion These data provide the first characterization of PID/PIPD maximums for ONH neural and connective tissue parameters in normal monkeys and serve to further clarify the location and character of early ONH change in experimental glaucoma. However, because of the species differences, the findings in EEG need to be confirmed within EEG rhesus monkey eyes. PMID:18775866

  11. Learning Integer Addition: Is Later Better?

    ERIC Educational Resources Information Center

    Aqazade, Mahtob; Bofferding, Laura; Farmer, Sherri

    2017-01-01

    We investigate thirty-three second and fifth-grade students' solution strategies on integer addition problems before and after analyzing contrasting cases with integer addition and participating in a lesson on integers. The students took a pretest, participated in two small group sessions and a short lesson, and took a posttest. Even though the…

  12. Online with Integers

    ERIC Educational Resources Information Center

    Siegel, Jonathan W.; Siegel, P. B.

    2011-01-01

    Integers are sometimes used in physics problems to simplify the mathematics so the arithmetic does not distract students from the physics concepts. This is particularly important in exams where students should not have to spend a lot of time using their calculators. Common uses of integers in physics problems include integer solutions to…

  13. Integers Made Easy: Just Walk It Off

    ERIC Educational Resources Information Center

    Nurnberger-Haag, Julie

    2007-01-01

    This article describes a multisensory method for teaching students how to multiply and divide as well as add and subtract integers. The author uses sidewalk chalk and the underlying concept of integers to physically and mentally engage students in understanding the concepts of integers, making connections, and developing computational fluency.…

  14. Lyapunov functions for a class of nonlinear systems using Caputo derivative

    NASA Astrophysics Data System (ADS)

    Fernandez-Anaya, G.; Nava-Antonio, G.; Jamous-Galante, J.; Muñoz-Vega, R.; Hernández-Martínez, E. G.

    2017-02-01

    This paper presents an extension of recent results that allow proving the stability of Caputo nonlinear and time-varying systems, by means of the fractional order Lyapunov direct method, using quadratic Lyapunov functions. This article introduces a new way of building polynomial Lyapunov functions of any positive integer order as a way of determining the stability of a greater variety of systems when the order of the derivative is 0 < α < 1. Some examples are given to validate these results.

  15. Higher order supersymmetric truncated oscillators

    NASA Astrophysics Data System (ADS)

    Fernández C., David J.; Morales-Salgado, Vicente Said

    2018-01-01

    We study the supersymmetric partners of the harmonic oscillator with an infinite potential barrier at the origin and obtain the conditions under which it is possible to add levels to the energy spectrum of these systems. It is found that instead of the usual rule for non-singular potentials, where the order of the transformation corresponds to the maximum number of levels which can be added, now it is the integer part of half the order of the transformation which gives the maximum number of levels to be created.

  16. Fractional two-compartmental model for articaine serum levels

    NASA Astrophysics Data System (ADS)

    Petronijevic, Branislava; Sarcev, Ivan; Zorica, Dusan; Janev, Marko; Atanackovic, Teodor M.

    2016-06-01

    Two fractional two-compartmental models are applied to the pharmacokinetics of articaine. Integer order derivatives are replaced by fractional derivatives, either of different, or of same orders. Models are formulated so that the mass balance is preserved. Explicit forms of the solutions are obtained in terms of the Mittag-Leffler functions. Pharmacokinetic parameters are determined by the use of the evolutionary algorithm and trust regions optimization to recover the experimental data.

  17. Fractional Order and Dynamic Simulation of a System Involving an Elastic Wide Plate

    NASA Astrophysics Data System (ADS)

    David, S. A.; Balthazar, J. M.; Julio, B. H. S.; Oliveira, C.

    2011-09-01

    Numerous researchers have studied about nonlinear dynamics in several areas of science and engineering. However, in most cases, these concepts have been explored mainly from the standpoint of analytical and computational methods involving integer order calculus (IOC). In this paper we have examined the dynamic behavior of an elastic wide plate induced by two electromagnets of a point of view of the fractional order calculus (FOC). The primary focus of this study is on to help gain a better understanding of nonlinear dynamic in fractional order systems.

  18. Increased Incidence of Fatigue in Patients with Primary Immunodeficiency Disorders: Prevalence and Associations Within the US Immunodeficiency Network Registry.

    PubMed

    Hajjar, Joud; Guffey, Danielle; Minard, Charles G; Orange, Jordan S

    2017-02-01

    Patients with primary immunodeficiency (PID) often report fatigue, yet this symptom has not been studied in PID. Fatigue affects 6-7.5% of healthy adults. The goal of this study is to estimate the prevalence of fatigue in patients with PID and investigate its associated factors. We analyzed 2537 PID patients registered in USIDNET to determine responses to the field "fatigue" in the core registry form. Demographics, immune phenotypes, and comorbid conditions were compared between fatigued and non-fatigued patients to identify relevant associations and potential drivers. A focused analysis was performed for patients with predominantly antibody deficiency disorders (PADs). Fatigue was reported in 25.9% (95% CI 23.7-28.3) of PAD patients, compared to 6.4% (95% CI 4.9-8.2) of non-PAD. Patients with common variable immunodeficiency (CVID) had the highest prevalence of fatigue (p < 0.001) among all PID diagnoses. Other factors that were associated with a higher rate of fatigue among PAD patients included female sex, higher BMI, depression, bronchiectasis, and autoimmunity. Additionally, fatigued PAD patients had lower absolute lymphocyte, CD3, CD4, and CD8 counts compared to non-fatigued patients. Our findings suggest that fatigue is overrepresented in PAD patients. Prospective studies to estimate prevalence, risk factors, and fatigue etiology in PID are warranted, so therapeutic interventions can be considered.

  19. The German national registry for primary immunodeficiencies (PID)

    PubMed Central

    Gathmann, B; Goldacker, S; Klima, M; Belohradsky, B H; Notheis, G; Ehl, S; Ritterbusch, H; Baumann, U; Meyer-Bahlburg, A; Witte, T; Schmidt, R; Borte, M; Borte, S; Linde, R; Schubert, R; Bienemann, K; Laws, H-J; Dueckers, G; Roesler, J; Rothoeft, T; Krüger, R; Scharbatke, E C; Masjosthusmann, K; Wasmuth, J-C; Moser, O; Kaiser, P; Groß-Wieltsch, U; Classen, C F; Horneff, G; Reiser, V; Binder, N; El-Helou, S M; Klein, C; Grimbacher, B; Kindle, G

    2013-01-01

    In 2009, a federally funded clinical and research consortium (PID–NET, http://www.pid-net.org) established the first national registry for primary immunodeficiencies (PID) in Germany. The registry contains clinical and genetic information on PID patients and is set up within the framework of the existing European Database for Primary Immunodeficiencies, run by the European Society for Primary Immunodeficiencies. Following the example of other national registries, a central data entry clerk has been employed to support data entry at the participating centres. Regulations for ethics approvals have presented a major challenge for participation of individual centres and have led to a delay in data entry in some cases. Data on 630 patients, entered into the European registry between 2004 and 2009, were incorporated into the national registry. From April 2009 to March 2012, the number of contributing centres increased from seven to 21 and 738 additional patients were reported, leading to a total number of 1368 patients, of whom 1232 were alive. The age distribution of living patients differs significantly by gender, with twice as many males than females among children, but 15% more women than men in the age group 30 years and older. The diagnostic delay between onset of symptoms and diagnosis has decreased for some PID over the past 20 years, but remains particularly high at a median of 4 years in common variable immunodeficiency (CVID), the most prevalent PID. PMID:23607573

  20. The Genetic and Environmental Sources of Resemblance Between Normative Personality and Personality Disorder Traits.

    PubMed

    Kendler, K S; Aggen, S H; Gillespie, Nathan; Neale, M C; Knudsen, G P; Krueger, R F; Czajkowski, Nikolai; Ystrom, Eivind; Reichborn-Kjennerud, T

    2017-04-01

    Recent work has suggested a high level of congruence between normative personality, most typically represented by the "big five" factors, and abnormal personality traits. In 2,293 Norwegian adult twins ascertained from a population-based registry, the authors evaluated the degree of sharing of genetic and environmental influences on normative personality, assessed by the Big Five Inventory (BFI), and personality disorder traits (PDTs), assessed by the Personality Inventory for DSM-5-Norwegian Brief Form (PID-5-NBF). For four of the five BFI dimensions, the strongest genetic correlation was observed with the expected PID-5-NBF dimension (e.g., neuroticism with negative affectivity [+], conscientiousness with disinhibition [-]). However, neuroticism, conscientiousness, and agreeableness had substantial genetic correlations with other PID-5-NBF dimensions (e.g., neuroticism with compulsivity [+], agreeableness with detachment [-]). Openness had no substantial genetic correlations with any PID-5-NBF dimension. The proportion of genetic risk factors shared in aggregate between the BFI traits and the PID-5-NBF dimensions was quite high for conscientiousness and neuroticism, relatively robust for extraversion and agreeableness, but quite low for openness. Of the six PID-5-NBF dimensions, three (negative affectivity, detachment, and disinhibition) shared, in aggregate, most of their genetic risk factors with normative personality traits. Genetic factors underlying psychoticism, antagonism, and compulsivity were shared to a lesser extent, suggesting that they are influenced by etiological factors not well indexed by the BFI.

  1. Borderline Personality Disorder and Personality Inventory for DSM-5 (PID-5): Dimensional personality assessment with DSM-5.

    PubMed

    Calvo, Natalia; Valero, Sergi; Sáez-Francàs, Naia; Gutiérrez, Fernando; Casas, Miguel; Ferrer, Marc

    2016-10-01

    Borderline personality disorder (BPD) diagnosis has been considered highly controversial. The Diagnostic and Statistical Manual of Mental Disorders 5th edition (DSM-5) proposes an alternative hybrid diagnostic model for personality disorders (PD), and the Personality Inventory for DSM-5 (PID-5) has adequate psychometric properties and has been widely used for the assessment of the dimensional component. Our aim was to analyze the utility of the personality traits presented in Section III of the DSM-5 for BPD diagnosis in an outpatient clinical sample, using the Spanish version of the PID-5. Two clinical samples were studied: BPD sample (n=84) and non-BPD sample (n=45). Between-sample differences in PID-5 scores were analyzed. The BPD sample obtained significantly higher scores in most PID-5 trait facets and domains. Specifically and after regression logistic analyses, in BPD patients, the domains of Negative Affectivity and Disinhibition, and the trait facets of emotional lability, [lack of] restricted affectivity, and impulsivity were more significantly associated with BPD. Although our findings are only partially consistent with the algorithm proposed by DSM-5, we consider that the combination of the PID-5 trait domains and facets could be useful for BPD dimensional diagnosis, and could further our understanding of BPD diagnosis complexity. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Successful treatment of lymphoproliferative disease complicating primary immunodeficiency/immunodysregulatory disorders with reduced-intensity allogeneic stem-cell transplantation.

    PubMed

    Cohen, Jonathan M; Sebire, Neil J; Harvey, Julia; Gaspar, H Bobby; Cathy, Cale; Jones, Alison; Rao, Kanchan; Cubitt, David; Amrolia, Persis J; Davies, E Graham; Veys, Paul

    2007-09-15

    Lymphoproliferative disease (LPD) is a recognized complication of primary immunodeficiency (PID) and immunodysregulatory syndromes. Historically, it has a very poor outcome. For patients surviving LPD, myeloablative hematopoietic stem cell transplantation (SCT) was the only cure for the underlying PID, with a high risk of developing posttransplantation complications, including recurrent lymphoproliferative disease. We describe 8 patients with a range of PID and immunodysregulatory syndromes complicated by LPD. After initial treatment of the LPD (including the use of anti-CD20 monoclonal antibody, rituximab, in 6 of the patients), all patients underwent reduced-intensity conditioning (RIC) SCT with prospective monitoring for Epstein-Barr virus (EBV) viremia. After transplantation, 3 patients received rituximab, and 3 patients received prophylactic EBV-specific cytotoxic T-lymphocytes. Only 1 patient developed recurrent LPD posttransplantation, which responded to rituximab. All patients who underwent transplantation survive free of LPD and are cured of their PID at a median follow-up of 4 years (range, 1-7 years). With careful monitoring and pre-emptive therapy, we advocate this RIC SCT approach to patients with PID who have pre-existing EBV-LPD.

  3. Early-Onset Autoimmune Disease as a Manifestation of Primary Immunodeficiency

    PubMed Central

    Carneiro-Sampaio, Magda; Coutinho, Antonio

    2015-01-01

    Autoimmune disorders (AID) have been increasingly observed in association with primary immunodeficiencies (PIDs). Here, we discuss the interface between PID and AID, focusing on autoimmune manifestations early in life, which can be diagnostic clues for underlying PIDs. Inflammatory bowel disease in infants and children has been associated with IL-10 and IL-10R deficiencies, chronic granulomatous disease, immunedysregulation-polyendocrinopathy-enteropathy-X-linked syndrome (IPEX), autoinflammatory disorders, and others. Some PIDs have been identified as underlying defects in juvenile systemic lupus erythematosus: C1q-, IgA-, IgM deficiencies, alterations of the IFN-α pathway (in Aicardi–Goutières syndrome due to TREX1 mutation). IPEX (due to FOXP3 mutation leading to Treg cell deficiency), usually appearing in the first months of life, was recently observed in miscarried fetuses with hydrops who presented with CD3+ infiltrating lymphocytes in the pancreas. Hemophagocytic lymphohistiocytosis due to perforin deficiency was also identified as a cause of fetal hydrops. In conclusion, PID should be suspected in any infant with signs of autoimmunity after excluding transferred maternal effects, or in children with multiple and/or severe AID. PMID:25999944

  4. Clinical comparison between patients with selective immunoglobulin A deficiency and other primary immunodeficiencies.

    PubMed

    Lozano, Natalia A; Lozano, Alejandro; Sasia, Laura V; Saranz, Ricardo J; Agresta, María Fernanda; del Pilar Bovina Martijena, María; Ianiero, Luciano; Grenat, Andrés R

    2015-04-01

    Primary immunodeficiencies (PID) are low-prevalence diseases. There are warning signs that may raise clinical suspicion. The objectives of this study were to describe the clinical characteristics and warning signs of patients with PID and to compare the clinical differences between selective immunoglobulin A (IgA) deficiency and other PIDs. Eighty-nine patients were studied; their median age at the time of diagnosis was 6 years old (4.08-11.67). Fifty-three (59.5%) patients were male. Fifty-four (60.7%) patients had selective IgA deficiency, and 35 (39.3%) had other PIDs. The main clinical manifestations were rhinopharyngitis in 65 (73.03%) patients and atopy in 39 (43.82%). Twenty- four (26.97%) patients showed warning signs, and none had selective IgA deficiency. Patients with other PIDs had a higher incidence of lower respiratory tract infection, sepsis, skin infections, mucocutaneous candidiasis, dental alterations, cardiovascular malformations, angioedema, hospitalizations and death. Ten (28.57%) patients received intravenous gammaglobulin, 15 (42.85%) antibiotic prophylaxis, and 2 (2.24%) antifungal prophylaxis.

  5. The DSM-5 alternative model of personality disorders from the perspective of adult attachment: a study in community-dwelling adults.

    PubMed

    Fossati, Andrea; Krueger, Robert F; Markon, Kristian E; Borroni, Serena; Maffei, Cesare; Somma, Antonella

    2015-04-01

    To assess how the maladaptive personality domains and facets that were included in the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) Alternative Model of Personality Disorders relate to adult attachment styles, 480 Italian nonclinical adults were administered the Personality Inventory for DSM-5 (PID-5) and the Attachment Style Questionnaire (ASQ). To evaluate the uniqueness of the associations between the PID-5 scales and the ASQ scales, the participants were also administered the Big Five Inventory (BFI). Multiple regression analyses showed that the ASQ scales significantly predicted both PID-5 domain scales and BFI scales; however, the relationships were different both qualitatively and quantitatively. With the exception of the PID-5 risk taking scale (adjusted R(2) = 0.02), all other PID-5 trait scales were significantly predicted by the ASQ scales, median adjusted R(2) value = 0.25, all ps < 0.001. Our findings suggest that the maladaptive personality domains and traits listed in the DSM-5 Alternative Model of Personality Disorders show meaningful associations with adult attachment styles.

  6. Potential-induced degradation of Cu(In,Ga)Se2 photovoltaic modules

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Seira; Jonai, Sachiko; Hara, Kohjiro; Komaki, Hironori; Shimizu-Kamikawa, Yukiko; Shibata, Hajime; Niki, Shigeru; Kawakami, Yuji; Masuda, Atsushi

    2015-08-01

    Potential-induced degradation (PID) of Cu(In,Ga)Se2 (CIGS) photovoltaic (PV) modules fabricated from integrated submodules is investigated. PID tests were performed by applying a voltage of -1000 V to connected submodule interconnector ribbons at 85 °C. The normalized energy conversion efficiency of a standard module decreases to 0.2 after the PID test for 14 days. This reveals that CIGS modules suffer PID under this experimental condition. In contrast, a module with non-alkali glass shows no degradation, which implies that the degradation occurs owing to alkali metal ions, e.g., Na+, migrating from the cover glass. The results of dynamic secondary ion mass spectrometry show Na accumulation in the n-ZnO transparent conductive oxide layer of the degraded module. A CIGS PV module with an ionomer (IO) encapsulant instead of a copolymer of ethylene and vinyl acetate shows no degradation. This reveals that the IO encapsulant can prevent PID of CIGS modules. A degraded module can recover from its performance losses by applying +1000 V to connected submodule interconnector ribbons from an Al plate placed on the test module.

  7. Development of a novel direct X-ray detector using photoinduced discharge (PID) readout for digital radiography

    NASA Astrophysics Data System (ADS)

    Heo, D.; Jeon, S.; Kim, J.-S.; Kim, R. K.; Cha, B. K.; Moon, B. J.; Yoon, J.

    2013-02-01

    We developed a novel direct X-ray detector using photoinduced discharge (PID) readout for digital radiography. The pixel resolution is 512 × 512 with 200 μm pixel and the overall active dimensions of the X-ray imaging panel is 10.24 cm × 10.24 cm. The detector consists of an X-ray absorption layer of amorphous selenium, a charge accumulation layer of metal, and a PID readout layer of amorphous silicon. In particular, the charge accumulation is pixelated because image charges generated by X-ray should be stored pixel by pixel. Here the image charges, or holes, are recombined with electrons generated by the PID method. We used a 405 nm laser diode and cylindrical lens to make a line beam source with a width of 50 μm for PID readout, which generates charges for each pixel lines during the scan. We obtained spatial frequencies of about 1.0 lp/mm for the X-direction (lateral direction) and 0.9 lp/mm for the Y-direction (scanning direction) at 50% modulation transfer function.

  8. Designing of new structure PID controller of boost converter for solar photovoltaic stability

    NASA Astrophysics Data System (ADS)

    Shabrina, Hanifati Nur; Setiawan, Eko Adhi; Sabirin, Chip Rinaldi

    2017-03-01

    Nowadays, the utilization of renewable energy as the source on distributed generation system is increasing. It aims to reduce reliance and power losses from utility grid and improve power stability in near loads. One example of renewable energy technology that have been highly proven on the market is solar photovoltaic (PV). This technology converts photon from sunlight into electricity. However, the fluctuation of solar radiation that often occurs become the main problem for this system. Due to this condition, the power conversion is needed to convert the change frequently in photovoltaic panel into a stable voltage to the system. Developing control of boost converter has important role to keep ability of system stabilization. A conventional PID (Proportional, Integral, Derivative) control is mostly used to achieve this goal. In this research, a design of new structure PID controller of boost converter is offered to better optimize system stability comparing to the conventional PID. Parameters obtained from this PID structure have been successfully yield a stable boost converter output at 200 V with 10% overshoot, 1.5 seconds of settling time, and 1.5% of steady-state error.

  9. Learning oncogenetic networks by reducing to mixed integer linear programming.

    PubMed

    Shahrabi Farahani, Hossein; Lagergren, Jens

    2013-01-01

    Cancer can be a result of accumulation of different types of genetic mutations such as copy number aberrations. The data from tumors are cross-sectional and do not contain the temporal order of the genetic events. Finding the order in which the genetic events have occurred and progression pathways are of vital importance in understanding the disease. In order to model cancer progression, we propose Progression Networks, a special case of Bayesian networks, that are tailored to model disease progression. Progression networks have similarities with Conjunctive Bayesian Networks (CBNs) [1],a variation of Bayesian networks also proposed for modeling disease progression. We also describe a learning algorithm for learning Bayesian networks in general and progression networks in particular. We reduce the hard problem of learning the Bayesian and progression networks to Mixed Integer Linear Programming (MILP). MILP is a Non-deterministic Polynomial-time complete (NP-complete) problem for which very good heuristics exists. We tested our algorithm on synthetic and real cytogenetic data from renal cell carcinoma. We also compared our learned progression networks with the networks proposed in earlier publications. The software is available on the website https://bitbucket.org/farahani/diprog.

  10. Nonlinear oscillator with power-form elastic-term: Fourier series expansion of the exact solution

    NASA Astrophysics Data System (ADS)

    Beléndez, Augusto; Francés, Jorge; Beléndez, Tarsicio; Bleda, Sergio; Pascual, Carolina; Arribas, Enrique

    2015-05-01

    A family of conservative, truly nonlinear, oscillators with integer or non-integer order nonlinearity is considered. These oscillators have only one odd power-form elastic-term and exact expressions for their period and solution were found in terms of Gamma functions and a cosine-Ateb function, respectively. Only for a few values of the order of nonlinearity, is it possible to obtain the periodic solution in terms of more common functions. However, for this family of conservative truly nonlinear oscillators we show in this paper that it is possible to obtain the Fourier series expansion of the exact solution, even though this exact solution is unknown. The coefficients of the Fourier series expansion of the exact solution are obtained as an integral expression in which a regularized incomplete Beta function appears. These coefficients are a function of the order of nonlinearity only and are computed numerically. One application of this technique is to compare the amplitudes for the different harmonics of the solution obtained using approximate methods with the exact ones computed numerically as shown in this paper. As an example, the approximate amplitudes obtained via a modified Ritz method are compared with the exact ones computed numerically.

  11. Making Sense of Integer Arithmetic: The Effect of Using Virtual Manipulatives on Students' Representational Fluency

    ERIC Educational Resources Information Center

    Bolyard, Johnna; Moyer-Packenham, Patricia

    2012-01-01

    This study investigated how the use of virtual manipulatives in integer instruction impacts student achievement for integer addition and subtraction. Of particular interest was the influence of using virtual manipulatives on students' ability to create and translate among representations for integer computation. The research employed a…

  12. Teachers' Construction of Meanings of Signed Quantities and Integer Operation

    ERIC Educational Resources Information Center

    Kumar, Ruchi S.; Subramaniam, K.; Naik, Shweta Shripad

    2017-01-01

    Understanding signed quantities and its arithmetic is one of the challenging topics of middle school mathematics. The "specialized content knowledge" (SCK) for teaching integers includes understanding of a variety of representations that may be used while teaching. In this study, we argue that meanings of integers and integer operations…

  13. Pelvic inflammatory disease risk following negative results from chlamydia nucleic acid amplification tests (NAATs) versus non-NAATs in Denmark: A retrospective cohort

    PubMed Central

    Frølund, Maria; Westh, Henrik

    2018-01-01

    Background Nucleic Acid Amplification Tests (NAATs) are the recommended test type for diagnosing Chlamydia trachomatis (chlamydia). However, less sensitive diagnostic methods—including direct immunofluorescence (IF) and enzyme-linked immunoassay (ELISA)—remain in use in lower resourced settings. We estimate the risk of pelvic inflammatory disease (PID) following undiagnosed infection in women tested with non-NAATs and estimate the health gain from using accurate diagnostic tests. Methods and findings We used Denmark’s national Chlamydia Study dataset to extract all chlamydia tests performed in women aged 15–34 years (1998–2001). Tests were categorised as non-NAAT (IF/ELISA) or NAAT and limited to each woman’s first test in the study period. We linked test data to hospital presentations for PID within 12 months from the Danish National Patient Register. The study included 272,105 women with a chlamydia test, just under half (44.78%, n = 121,857) were tested using NAATs. Overall, 6.38% (n = 17,353) tested positive for chlamydia and 0.64% (n = 1,732) were diagnosed with PID within 12 months. The risk of PID following a positive chlamydia test did not differ by test type (NAAT 0.81% [95% CI 0.61–1.00], non-NAAT 0.78% [0.59–0.96]). The risk of PID following a negative test was significantly lower in women tested with NAATs compared to non-NAATs (0.55% [0.51–0.59] compared to 0.69% [0.64–0.73]; adjusted odds ratio (AOR) 0.83 [0.75–0.93]). We estimate that 18% of chlamydia infections in women tested with a non-NAAT were undiagnosed and that the risk of progression from undiagnosed chlamydia infection to PID within 12 months was 9.52% (9.30–9.68). Using non-NAATs could lead to an excess 120 cases of PID per 100,000 women tested compared to using NAATs. The key limitations of this study are under ascertainment of PID cases, misclassification bias in chlamydia and PID exposure status, bias to the association between clinical presentation and test type and the presence of unmeasured confounders (including other sexually transmitted infection [STI] diagnoses and clinical indication for chlamydia test). Conclusion This retrospective observational study estimates the positive impact on women’s reproductive health from using accurate chlamydia diagnostic tests and provides further evidence for restricting the use of inferior tests. Women with a negative chlamydia test have a 17% higher adjusted risk of PID by 12 months if they are tested using a non-NAAT compared to a NAAT. PMID:29293503

  14. Design of a temperature control system using incremental PID algorithm for a special homemade shortwave infrared spatial remote sensor based on FPGA

    NASA Astrophysics Data System (ADS)

    Xu, Zhipeng; Wei, Jun; Li, Jianwei; Zhou, Qianting

    2010-11-01

    An image spectrometer of a spatial remote sensing satellite requires shortwave band range from 2.1μm to 3μm which is one of the most important bands in remote sensing. We designed an infrared sub-system of the image spectrometer using a homemade 640x1 InGaAs shortwave infrared sensor working on FPA system which requires high uniformity and low level of dark current. The working temperature should be -15+/-0.2 Degree Celsius. This paper studies the model of noise for focal plane array (FPA) system, investigated the relationship with temperature and dark current noise, and adopts Incremental PID algorithm to generate PWM wave in order to control the temperature of the sensor. There are four modules compose of the FPGA module design. All of the modules are coded by VHDL and implemented in FPGA device APA300. Experiment shows the intelligent temperature control system succeeds in controlling the temperature of the sensor.

  15. Neural net controller for inlet pressure control of rocket engine testing

    NASA Technical Reports Server (NTRS)

    Trevino, Luis C.

    1994-01-01

    Many dynamic systems operate in select operating regions, each exhibiting characteristic modes of behavior. It is traditional to employ standard adjustable gain proportional-integral-derivative (PID) loops in such systems where no apriori model information is available. However, for controlling inlet pressure for rocket engine testing, problems in fine tuning, disturbance accommodation, and control gains for new profile operating regions (for research and development) are typically encountered. Because of the capability of capturing I/O peculiarities, using NETS, a back propagation trained neural network is specified. For select operating regions, the neural network controller is simulated to be as robust as the PID controller. For a comparative analysis, the higher order moment neural array (HOMNA) method is used to specify a second neural controller by extracting critical exemplars from the I/O data set. Furthermore, using the critical exemplars from the HOMNA method, a third neural controller is developed using NETS back propagation algorithm. All controllers are benchmarked against each other.

  16. Adaptive fuzzy PID control of hydraulic servo control system for large axial flow compressor

    NASA Astrophysics Data System (ADS)

    Wang, Yannian; Wu, Peizhi; Liu, Chengtao

    2017-09-01

    To improve the stability of the large axial compressor, an efficient and special intelligent hydraulic servo control system is designed and implemented. The adaptive fuzzy PID control algorithm is used to control the position of the hydraulic servo cylinder steadily, which overcomes the drawback that the PID parameters should be adjusted based on the different applications. The simulation and the test results show that the system has a better dynamic property and a stable state performance.

  17. Faddeev calculations of. pi. D scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, A.W.

    1976-01-01

    The present status of the Faddeev calculations of ..pi..D scattering is summarized, with emphasis on what has been learned about common approximation methods (for ..pi..-nucleus as well as ..pi..D). Some space is devoted to a discussion of the theoretical work which remains, including a suggestion of co-operation between theorists on a ''homework'' problem. Finally, examples of the interesting phenomena are given which one hopes to investigate through good ..pi..D experiments. Suggestions are made as to which experiments would be most useful.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giovannetti, Vittorio; Lloyd, Seth; Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139

    The Amosov-Holevo-Werner conjecture implies the additivity of the minimum Renyi entropies at the output of a channel. The conjecture is proven true for all Renyi entropies of integer order greater than two in a class of Gaussian bosonic channel where the input signal is randomly displaced or where it is coupled linearly to an external environment.

  19. Critical Branches and Lucky Loads in Control-Independence Architectures

    ERIC Educational Resources Information Center

    Malik, Kshitiz

    2009-01-01

    Branch mispredicts have a first-order impact on the performance of integer applications. Control Independence (CI) architectures aim to overlap the penalties of mispredicted branches with useful execution by spawning control-independent work as separate threads. Although control independent, such threads may consume register and memory values…

  20. Core barrier formation near integer q surfaces in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Austin, M. E.; Gentle, K. W.; Burrell, K. H.

    2006-08-15

    Recent DIII-D experiments have significantly improved the understanding of internal transport barriers (ITBs) that are triggered close to the time when an integer value of the minimum in q is crossed. While this phenomenon has been observed on many tokamaks, the extensive transport and fluctuation diagnostics on DIII-D have permitted a detailed study of the generation mechanisms of q-triggered ITBs as pertaining to turbulence suppression dynamics, shear flows, and energetic particle modes. In these discharges, the evolution of the q profile is measured using motional Stark effect polarimetry and the integer q{sub min} crossings are further pinpointed in time bymore » the observation of Alfven cascades. High time resolution measurements of the ion and electron temperatures and the toroidal rotation show that the start of improved confinement is simultaneous in all three channels, and that this event precedes the traversal of integer q{sub min} by 5-20 ms. There is no significant low-frequency magnetohydrodynamic activity prior to or just after the crossing of the integer q{sub min} and hence magnetic reconnection is determined not to be the precipitant of the confinement change. Instead, results from the GYRO code point to the effects of zonal flows near low order rational q values as playing a role in ITB triggering. A reduction in local turbulent fluctuations is observed at the start of the temperature rise and, concurrently, an increase in turbulence poloidal flow velocity and flow shear is measured with the beam emission spectroscopy diagnostic. For the case of a transition to an enduring internal barrier the fluctuation level remains at a reduced amplitude. The timing and nature of the temperature, rotation, and fluctuation changes leading to internal barriers suggests transport improvement due to increased shear flow arising from the zonal flow structures.« less

  1. A simple approximation of moments of the quasi-equilibrium distribution of an extended stochastic theta-logistic model with non-integer powers.

    PubMed

    Bhowmick, Amiya Ranjan; Bandyopadhyay, Subhadip; Rana, Sourav; Bhattacharya, Sabyasachi

    2016-01-01

    The stochastic versions of the logistic and extended logistic growth models are applied successfully to explain many real-life population dynamics and share a central body of literature in stochastic modeling of ecological systems. To understand the randomness in the population dynamics of the underlying processes completely, it is important to have a clear idea about the quasi-equilibrium distribution and its moments. Bartlett et al. (1960) took a pioneering attempt for estimating the moments of the quasi-equilibrium distribution of the stochastic logistic model. Matis and Kiffe (1996) obtain a set of more accurate and elegant approximations for the mean, variance and skewness of the quasi-equilibrium distribution of the same model using cumulant truncation method. The method is extended for stochastic power law logistic family by the same and several other authors (Nasell, 2003; Singh and Hespanha, 2007). Cumulant truncation and some alternative methods e.g. saddle point approximation, derivative matching approach can be applied if the powers involved in the extended logistic set up are integers, although plenty of evidence is available for non-integer powers in many practical situations (Sibly et al., 2005). In this paper, we develop a set of new approximations for mean, variance and skewness of the quasi-equilibrium distribution under more general family of growth curves, which is applicable for both integer and non-integer powers. The deterministic counterpart of this family of models captures both monotonic and non-monotonic behavior of the per capita growth rate, of which theta-logistic is a special case. The approximations accurately estimate the first three order moments of the quasi-equilibrium distribution. The proposed method is illustrated with simulated data and real data from global population dynamics database. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Dynamic analysis and control PID path of a model type gantry crane

    NASA Astrophysics Data System (ADS)

    Ospina-Henao, P. A.; López-Suspes, Framsol

    2017-06-01

    This paper presents an alternate form for the dynamic modelling of a mechanical system that simulates in real life a gantry crane type, using Euler’s classical mechanics and Lagrange formalism, which allows find the equations of motion that our model describe. Moreover, it has a basic model design system using the SolidWorks software, based on the material and dimensions of the model provides some physical variables necessary for modelling. In order to verify the theoretical results obtained, a contrast was made between solutions obtained by simulation in SimMechanics-Matlab and Euler-Lagrange equations system, has been solved through Matlab libraries for solving equation’s systems of the type and order obtained. The force is determined, but not as exerted by the spring, as this will be the control variable. The objective is to bring the mass of the pendulum from one point to another with a specified distance without the oscillation from it, so that, the answer is overdamped. This article includes an analysis of PID control in which the equations of motion of Euler-Lagrange are rewritten in the state space, once there, they were implemented in Simulink to get the natural response of the system to a step input in F and then draw the desired trajectories.

  3. Enhancing the stabilization of aircraft pitch motion control via intelligent and classical method

    NASA Astrophysics Data System (ADS)

    Lukman, H.; Munawwarah, S.; Azizan, A.; Yakub, F.; Zaki, S. A.; Rasid, Z. A.

    2017-12-01

    The pitching movement of an aircraft is very important to ensure passengers are intrinsically safe and the aircraft achieve its maximum stability. The equations governing the motion of an aircraft are a complex set of six nonlinear coupled differential equations. Under certain assumptions, it can be decoupled and linearized into longitudinal and lateral equations. Pitch control is a longitudinal problem and thus, only the longitudinal dynamics equations are involved in this system. It is a third order nonlinear system, which is linearized about the operating point. The system is also inherently unstable due to the presence of a free integrator. Because of this, a feedback controller is added in order to solve this problem and enhance the system performance. This study uses two approaches in designing controller: a conventional controller and an intelligent controller. The pitch control scheme consists of proportional, integral and derivatives (PID) for conventional controller and fuzzy logic control (FLC) for intelligent controller. Throughout the paper, the performance of the presented controllers are investigated and compared based on the common criteria of step response. Simulation results have been obtained and analysed by using Matlab and Simulink software. The study shows that FLC controller has higher ability to control and stabilize the aircraft's pitch angle as compared to PID controller.

  4. Experimental realization of Shor's quantum factoring algorithm using nuclear magnetic resonance.

    PubMed

    Vandersypen, L M; Steffen, M; Breyta, G; Yannoni, C S; Sherwood, M H; Chuang, I L

    The number of steps any classical computer requires in order to find the prime factors of an l-digit integer N increases exponentially with l, at least using algorithms known at present. Factoring large integers is therefore conjectured to be intractable classically, an observation underlying the security of widely used cryptographic codes. Quantum computers, however, could factor integers in only polynomial time, using Shor's quantum factoring algorithm. Although important for the study of quantum computers, experimental demonstration of this algorithm has proved elusive. Here we report an implementation of the simplest instance of Shor's algorithm: factorization of N = 15 (whose prime factors are 3 and 5). We use seven spin-1/2 nuclei in a molecule as quantum bits, which can be manipulated with room temperature liquid-state nuclear magnetic resonance techniques. This method of using nuclei to store quantum information is in principle scalable to systems containing many quantum bits, but such scalability is not implied by the present work. The significance of our work lies in the demonstration of experimental and theoretical techniques for precise control and modelling of complex quantum computers. In particular, we present a simple, parameter-free but predictive model of decoherence effects in our system.

  5. The computational complexity of elliptic curve integer sub-decomposition (ISD) method

    NASA Astrophysics Data System (ADS)

    Ajeena, Ruma Kareem K.; Kamarulhaili, Hailiza

    2014-07-01

    The idea of the GLV method of Gallant, Lambert and Vanstone (Crypto 2001) is considered a foundation stone to build a new procedure to compute the elliptic curve scalar multiplication. This procedure, that is integer sub-decomposition (ISD), will compute any multiple kP of elliptic curve point P which has a large prime order n with two low-degrees endomorphisms ψ1 and ψ2 of elliptic curve E over prime field Fp. The sub-decomposition of values k1 and k2, not bounded by ±C√n , gives us new integers k11, k12, k21 and k22 which are bounded by ±C√n and can be computed through solving the closest vector problem in lattice. The percentage of a successful computation for the scalar multiplication increases by ISD method, which improved the computational efficiency in comparison with the general method for computing scalar multiplication in elliptic curves over the prime fields. This paper will present the mechanism of ISD method and will shed light mainly on the computation complexity of the ISD approach that will be determined by computing the cost of operations. These operations include elliptic curve operations and finite field operations.

  6. Software Technology for Adaptable, Reliable Systems (STARS) (User Manual). Ada Command Environment (ACE) Version 8.0 Sun OS Implementation

    DTIC Science & Technology

    1990-10-29

    the equivalent type names in the basic X libary . 37. Intrinsics Contains the type declarations common to all Xt toolkit routines. 38. Widget-Package...Memory-Size constant Integer 1; MinInt constant I-reger Integer’First; MaxInt const-i’ integer Integer’Last; -- Max- Digits constant Integer 1; -- MaxMan...connection between some type names used by Xt routines and the equivalent type names in the basic X libary . .package RenamedXlibTypes is P;’ge 65 29

  7. Pelvic Inflammatory Disease

    MedlinePlus

    Pelvic inflammatory disease (PID) is an infection and inflammation of the uterus, ovaries, and other female reproductive organs. It causes scarring ... United States. Gonorrhea and chlamydia, two sexually transmitted diseases, are the most common causes of PID. Other ...

  8. A solution procedure for mixed-integer nonlinear programming formulation of supply chain planning with quantity discounts under demand uncertainty

    NASA Astrophysics Data System (ADS)

    Yin, Sisi; Nishi, Tatsushi

    2014-11-01

    Quantity discount policy is decision-making for trade-off prices between suppliers and manufacturers while production is changeable due to demand fluctuations in a real market. In this paper, quantity discount models which consider selection of contract suppliers, production quantity and inventory simultaneously are addressed. The supply chain planning problem with quantity discounts under demand uncertainty is formulated as a mixed-integer nonlinear programming problem (MINLP) with integral terms. We apply an outer-approximation method to solve MINLP problems. In order to improve the efficiency of the proposed method, the problem is reformulated as a stochastic model replacing the integral terms by using a normalisation technique. We present numerical examples to demonstrate the efficiency of the proposed method.

  9. Update on gene therapy for immunodeficiencies.

    PubMed

    Kohn, Donald B

    2010-05-01

    Primary immune deficiencies (PID) are due to blood cell defects and can be treated with transplantation of normal hematopoietic stem cells (HSC) from another person (allogeneic). Gene therapy in which a patient's autologous HSC are genetically corrected represents an alternative treatment for patients with PID, which could avoid the immunologic risks of allogeneic HSCT and confer similar benefits. Recent clinical trials using gene therapy have led to immune restoration in patients with X-linked severe combined immune deficiency (XSCID), adenosine deaminase (ADA)-deficient SCID and chronic granulomatous disease (CGD). However, severe complications arose in several of the patients in whom the integrated retroviral vectors led to leukoproliferative disorders. New approaches using safer integrating vectors or direct correction of the defective gene underlying the PID are being developed and may lead to safer and effective gene therapy for PID. Copyright 2009 Elsevier Inc. All rights reserved.

  10. Flight representative positive isolation disconnect

    NASA Technical Reports Server (NTRS)

    Rosener, A. A.; Jonkoniec, T. G.

    1977-01-01

    Resolutions were developed for each problem encountered and a tradeoff analysis was performed to select a final configuration for a flight representative PID (Positive Isolation Disconnect) that is reduced in size and comparable in weight and pressure drop to the developmental PID. A 6.35 mm (1/4-inch) line size PID was fabricated and tested. The flight representative PID consists of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique prevents uncoupling of disconnect halves prior to fluid isolation. Future development efforts for the Space Shuttle subsystems that would benefit from the use of the positive isolation disconnect are also recommended. Customary units were utilized for principal measurements and calculations with conversion factors being inserted in equations to convert the results to the international system of units.

  11. Quantum Efficiency Loss after PID Stress: Wavelength Dependence on Cell Surface and Cell Edge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, Jaewon; Bowden, Stuart; TamizhMani, GovindaSamy

    2015-06-14

    It is known that the potential induced degradation (PID) stress of conventional p-base solar cells affects power, shunt resistance, junction recombination, and quantum efficiency (QE). One of the primary solutions to address the PID issue is a modification of chemical and physical properties of antireflection coating (ARC) on the cell surface. Depending on the edge isolation method used during cell processing, the ARC layer near the edges may be uniformly or non-uniformly damaged. Therefore, the pathway for sodium migration from glass to the cell junction could be either through all of the ARC surface if surface and edge ARC havemore » low quality or through the cell edge if surface ARC has high quality but edge ARC is defective due to certain edge isolation process. In this study, two PID susceptible cells from two different manufacturers have been investigated. The QE measurements of these cells before and after PID stress were performed at both surface and edge. We observed the wavelength dependent QE loss only in the first manufacturer's cell but not in the second manufacturer's cell. The first manufacturer's cell appeared to have low quality ARC whereas the second manufacturer's cell appeared to have high quality ARC with defective edge. To rapidly screen a large number of cells for PID stress testing, a new but simple test setup that does not require laminated cell coupon has been developed and is used in this investigation.« less

  12. Increased Incidence of Fatigue in Patients with Primary Immunodeficiency Disorders: Prevalence and Associations Within the US Immunodeficiency Network Registry

    PubMed Central

    Guffey, Danielle; Minard, Charles G.; Orange, Jordan S.

    2017-01-01

    Introduction Patients with primary immunodeficiency (PID) often report fatigue, yet this symptom has not been studied in PID. Fatigue affects 6–7.5% of healthy adults. The goal of this study is to estimate the prevalence of fatigue in patients with PID and investigate its associated factors. Methods We analyzed 2537 PID patients registered in USIDNET to determine responses to the field “fatigue” in the core registry form. Demographics, immune phenotypes, and comorbid conditions were compared between fatigued and non-fatigued patients to identify relevant associations and potential drivers. A focused analysis was performed for patients with predominantly antibody deficiency disorders (PADs). Results Fatigue was reported in 25.9%(95% CI 23.7–28.3) of PAD patients, compared to 6.4% (95% CI 4.9–8.2) of non-PAD. Patients with common variable immunodeficiency (CVID) had the highest prevalence of fatigue (p < 0.001) among all PID diagnoses. Other factors that were associated with a higher rate of fatigue among PAD patients included female sex, higher BMI, depression, bronchiectasis, and autoimmunity. Additionally, fatigued PAD patients had lower absolute lymphocyte, CD3, CD4, and CD8 counts compared to non-fatigued patients. Conclusion Our findings suggest that fatigue is overrepresented in PAD patients. Prospective studies to estimate prevalence, risk factors, and fatigue etiology in PID are warranted, so therapeutic interventions can be considered. PMID:28124237

  13. Counting Triangles to Sum Squares

    ERIC Educational Resources Information Center

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  14. Slip and Slide Method of Factoring Trinomials with Integer Coefficients over the Integers

    ERIC Educational Resources Information Center

    Donnell, William A.

    2012-01-01

    In intermediate and college algebra courses there are a number of methods for factoring quadratic trinomials with integer coefficients over the integers. Some of these methods have been given names, such as trial and error, reversing FOIL, AC method, middle term splitting method and slip and slide method. The purpose of this article is to discuss…

  15. Solving Integer Programs from Dependence and Synchronization Problems

    DTIC Science & Technology

    1993-03-01

    DEFF.NSNE Solving Integer Programs from Dependence and Synchronization Problems Jaspal Subhlok March 1993 CMU-CS-93-130 School of Computer ScienceT IC...method Is an exact and efficient way of solving integer programming problems arising in dependence and synchronization analysis of parallel programs...7/;- p Keywords: Exact dependence tesing, integer programming. parallelilzng compilers, parallel program analysis, synchronization analysis Solving

  16. Obstacles and Affordances for Integer Reasoning: An Analysis of Children's Thinking and the History of Mathematics

    ERIC Educational Resources Information Center

    Bishop, Jessica Pierson; Lamb, Lisa L.; Philipp, Randolph A.; Whitacre, Ian; Schappelle, Bonnie P.; Lewis, Melinda L.

    2014-01-01

    We identify and document 3 cognitive obstacles, 3 cognitive affordances, and 1 type of integer understanding that can function as either an obstacle or affordance for learners while they extend their numeric domains from whole numbers to include negative integers. In particular, we highlight 2 key subsets of integer reasoning: understanding or…

  17. Evaluation of plasma-induced damage and bias temperature instability depending on type of antenna layer using current-starved ring oscillators

    NASA Astrophysics Data System (ADS)

    Kishida, Ryo; Furuta, Jun; Kobayashi, Kazutoshi

    2018-04-01

    Plasma-induced damage (PID) and bias temperature instability (BTI) are inevitable reliability issues that degrade the performance of transistors. In this study, PID and BTI, depending on the type of antenna layer, are evaluated in current-starved ring oscillators (ROs) to separate degradations in PMOS and NMOS transistors in a 65 nm silicon-on-insulator (SOI) process. Oscillation frequencies of ROs fluctuate with the performance of MOSFET switches between power/ground rails and virtual power/ground nodes. The initial frequencies of ROs with PMOS switches having antennas on upper layers decrease. However, those with NMOS switches become higher than those without PID because high-k dielectrics are damaged by positive charges. The degradation induced by negative BTI (NBTI) in PMOS is 1.5 times larger than that induced by positive BTI (PBTI) in NMOS. However, both NBTI- and PBTI-induced degradations are the same among different antenna layers. The frequency fluctuation caused by PID is converted to threshold voltage shifts by circuit simulations. Threshold voltages shift by 8.4 and 11% owing to PID in PMOS and NMOS transistors, respectively.

  18. ? PID output-feedback control under event-triggered protocol

    NASA Astrophysics Data System (ADS)

    Zhao, Di; Wang, Zidong; Ding, Derui; Wei, Guoliang; Alsaadi, Fuad E.

    2018-07-01

    This paper is concerned with the ? proportional-integral-derivative (PID) output-feedback control problem for a class of linear discrete-time systems under event-triggered protocols. The controller and the actuators are connected through a communication network of limited bandwidth, and an event-triggered communication mechanism is adopted to decide when a certain control signal should be transmitted to the respective actuator. Furthermore, a novel PID output-feedback controller is designed where the accumulative sum-loop (the counterpart to the integral-loop in the continues-time setting) operates on a limited time-window with hope to mitigate the effect from the past measurement data. The main objective of the problem under consideration is to design a desired PID controller such that the closed-loop system is exponentially stable and the prescribed ? disturbance rejection attenuation level is guaranteed under event-triggered protocols. By means of the Lyapunov stability theory combined with the orthogonal decomposition, sufficient conditions are established under which the addressed PID controller design problem is recast into a linear convex optimization one that can be easily solved via available software packages. Finally, a simulation example is exploited to illustrate the usefulness and effectiveness of the established control scheme.

  19. In vivo imaging of cidofovir treatment of cowpox virus infection.

    PubMed

    Goff, Arthur; Twenhafel, Nancy; Garrison, Aura; Mucker, Eric; Lawler, James; Paragas, Jason

    2007-09-01

    Variola virus and other members of the genus Orthopoxviruses constitute a prominent bioterrorism and public health threat. Treatment with the anti-viral drug cidofovir inhibits replication of orthopoxviruses in vitro and in vivo. In this study, we visualized the effect of cidofovir on viral kinetics in orthopoxvirus infected mice by using whole-body fluorescence imaging (FI). We engineered a cowpox virus (CPV) expressing the enhanced green fluorescent protein (GFP). Single-step growth curves and calculated 50% lethal doses (LD(50)) of wild-type CPX (Wt-CPV) and GFP-expressing CPX (GFP-CPV) were comparable. Whole-body FI first detected GFP fluorescence in the mesenteric tissue of untreated animals on post-infection day (PID) 1. On PID 3 GFP signal was detected throughout the mesentery, in all abdominal organs by PID 5 and in most major organs, except for the heart and brain by PID 6. Infected animals treated with 25mg/kg of cidofovir also began showing signs of viral replication on PID 1, however, the fluorescent signal was limited only to discrete foci throughout the course of the infection. This work describes the first use of an established Orthopox model of infection to evaluate drug efficacy and track virus progression on a macroscopic level.

  20. Monitoring of piglets' open field activity and choice behaviour during the replay of maternal vocalization: a comparison between Observer and PID technique.

    PubMed

    Puppe, B; Schön, P C; Wendland, K

    1999-07-01

    The paper presents a new system for the automatic monitoring of open field activity and choice behaviour of medium-sized animals. Passive infrared motion detectors (PID) were linked on-line via a digital I/O interface to a personal computer provided with self-developed analysis software based on LabVIEW (PID technique). The set up was used for testing 18 one-week-old piglets (Sus scrofa) for their approach to their mother's nursing vocalization replayed through loudspeakers. The results were validated by comparison with a conventional Observer technique, a computer-aided direct observation. In most of the cases, no differences were seen between the Observer and PID technique regarding the percentage of stay in previously defined open field segments, the locomotor open field activity, and the choice behaviour. The results revealed that piglets are clearly attracted by their mother's nursing vocalization. The monitoring system presented in this study is thus suitable for detailed behavioural investigations of individual acoustic recognition. In general, the PID technique is a useful tool for research into the behaviour of individual animals in a restricted open field which does not rely on subjective analysis by a human observer.

  1. Sequential computation of elementary modes and minimal cut sets in genome-scale metabolic networks using alternate integer linear programming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Hyun-Seob; Goldberg, Noam; Mahajan, Ashutosh

    Elementary (flux) modes (EMs) have served as a valuable tool for investigating structural and functional properties of metabolic networks. Identification of the full set of EMs in genome-scale networks remains challenging due to combinatorial explosion of EMs in complex networks. It is often, however, that only a small subset of relevant EMs needs to be known, for which optimization-based sequential computation is a useful alternative. Most of the currently available methods along this line are based on the iterative use of mixed integer linear programming (MILP), the effectiveness of which significantly deteriorates as the number of iterations builds up. Tomore » alleviate the computational burden associated with the MILP implementation, we here present a novel optimization algorithm termed alternate integer linear programming (AILP). Results: Our algorithm was designed to iteratively solve a pair of integer programming (IP) and linear programming (LP) to compute EMs in a sequential manner. In each step, the IP identifies a minimal subset of reactions, the deletion of which disables all previously identified EMs. Thus, a subsequent LP solution subject to this reaction deletion constraint becomes a distinct EM. In cases where no feasible LP solution is available, IP-derived reaction deletion sets represent minimal cut sets (MCSs). Despite the additional computation of MCSs, AILP achieved significant time reduction in computing EMs by orders of magnitude. The proposed AILP algorithm not only offers a computational advantage in the EM analysis of genome-scale networks, but also improves the understanding of the linkage between EMs and MCSs.« less

  2. Techniques for computing the discrete Fourier transform using the quadratic residue Fermat number systems

    NASA Technical Reports Server (NTRS)

    Truong, T. K.; Chang, J. J.; Hsu, I. S.; Pei, D. Y.; Reed, I. S.

    1986-01-01

    The complex integer multiplier and adder over the direct sum of two copies of finite field developed by Cozzens and Finkelstein (1985) is specialized to the direct sum of the rings of integers modulo Fermat numbers. Such multiplication over the rings of integers modulo Fermat numbers can be performed by means of two integer multiplications, whereas the complex integer multiplication requires three integer multiplications. Such multiplications and additions can be used in the implementation of a discrete Fourier transform (DFT) of a sequence of complex numbers. The advantage of the present approach is that the number of multiplications needed to compute a systolic array of the DFT can be reduced substantially. The architectural designs using this approach are regular, simple, expandable and, therefore, naturally suitable for VLSI implementation.

  3. PID-based error signal modeling

    NASA Astrophysics Data System (ADS)

    Yohannes, Tesfay

    1997-10-01

    This paper introduces a PID based signal error modeling. The error modeling is based on the betterment process. The resulting iterative learning algorithm is introduced and a detailed proof is provided for both linear and nonlinear systems.

  4. PID techniques: Alternatives to RICH methods

    DOE PAGES

    Va’vra, J.

    2017-07-05

    Here, in this review article we discuss new updates on PID techniques, other than the Cherenkov method. In particular, we discuss recent efforts to develop high resolution timing, placing an emphasis on small scale test results.

  5. BROJA-2PID: A Robust Estimator for Bivariate Partial Information Decomposition

    NASA Astrophysics Data System (ADS)

    Makkeh, Abdullah; Theis, Dirk; Vicente, Raul

    2018-04-01

    Makkeh, Theis, and Vicente found in [8] that Cone Programming model is the most robust to compute the Bertschinger et al. partial information decompostion (BROJA PID) measure [1]. We developed a production-quality robust software that computes the BROJA PID measure based on the Cone Programming model. In this paper, we prove the important property of strong duality for the Cone Program and prove an equivalence between the Cone Program and the original Convex problem. Then describe in detail our software and how to use it.\

  6. Software For Integer Programming

    NASA Technical Reports Server (NTRS)

    Fogle, F. R.

    1992-01-01

    Improved Exploratory Search Technique for Pure Integer Linear Programming Problems (IESIP) program optimizes objective function of variables subject to confining functions or constraints, using discrete optimization or integer programming. Enables rapid solution of problems up to 10 variables in size. Integer programming required for accuracy in modeling systems containing small number of components, distribution of goods, scheduling operations on machine tools, and scheduling production in general. Written in Borland's TURBO Pascal.

  7. Fractional modeling of viscoelasticity in 3D cerebral arteries and aneurysms

    NASA Astrophysics Data System (ADS)

    Yu, Yue; Perdikaris, Paris; Karniadakis, George Em

    2016-10-01

    We develop efficient numerical methods for fractional order PDEs, and employ them to investigate viscoelastic constitutive laws for arterial wall mechanics. Recent simulations using one-dimensional models [1] have indicated that fractional order models may offer a more powerful alternative for modeling the arterial wall response, exhibiting reduced sensitivity to parametric uncertainties compared with the integer-calculus-based models. Here, we study three-dimensional (3D) fractional PDEs that naturally model the continuous relaxation properties of soft tissue, and for the first time employ them to simulate flow structure interactions for patient-specific brain aneurysms. To deal with the high memory requirements and in order to accelerate the numerical evaluation of hereditary integrals, we employ a fast convolution method [2] that reduces the memory cost to O (log ⁡ (N)) and the computational complexity to O (Nlog ⁡ (N)). Furthermore, we combine the fast convolution with high-order backward differentiation to achieve third-order time integration accuracy. We confirm that in 3D viscoelastic simulations, the integer order models strongly depends on the relaxation parameters, while the fractional order models are less sensitive. As an application to long-time simulations in complex geometries, we also apply the method to modeling fluid-structure interaction of a 3D patient-specific compliant cerebral artery with an aneurysm. Taken together, our findings demonstrate that fractional calculus can be employed effectively in modeling complex behavior of materials in realistic 3D time-dependent problems if properly designed efficient algorithms are employed to overcome the extra memory requirements and computational complexity associated with the non-local character of fractional derivatives.

  8. Fractional modeling of viscoelasticity in 3D cerebral arteries and aneurysms

    PubMed Central

    Perdikaris, Paris; Karniadakis, George Em

    2017-01-01

    We develop efficient numerical methods for fractional order PDEs, and employ them to investigate viscoelastic constitutive laws for arterial wall mechanics. Recent simulations using one-dimensional models [1] have indicated that fractional order models may offer a more powerful alternative for modeling the arterial wall response, exhibiting reduced sensitivity to parametric uncertainties compared with the integer-calculus-based models. Here, we study three-dimensional (3D) fractional PDEs that naturally model the continuous relaxation properties of soft tissue, and for the first time employ them to simulate flow structure interactions for patient-specific brain aneurysms. To deal with the high memory requirements and in order to accelerate the numerical evaluation of hereditary integrals, we employ a fast convolution method [2] that reduces the memory cost to O(log(N)) and the computational complexity to O(N log(N)). Furthermore, we combine the fast convolution with high-order backward differentiation to achieve third-order time integration accuracy. We confirm that in 3D viscoelastic simulations, the integer order models strongly depends on the relaxation parameters, while the fractional order models are less sensitive. As an application to long-time simulations in complex geometries, we also apply the method to modeling fluid–structure interaction of a 3D patient-specific compliant cerebral artery with an aneurysm. Taken together, our findings demonstrate that fractional calculus can be employed effectively in modeling complex behavior of materials in realistic 3D time-dependent problems if properly designed efficient algorithms are employed to overcome the extra memory requirements and computational complexity associated with the non-local character of fractional derivatives. PMID:29104310

  9. An INAR(1) Negative Multinomial Regression Model for Longitudinal Count Data.

    ERIC Educational Resources Information Center

    Bockenholt, Ulf

    1999-01-01

    Discusses a regression model for the analysis of longitudinal count data in a panel study by adapting an integer-valued first-order autoregressive (INAR(1)) Poisson process to represent time-dependent correlation between counts. Derives a new negative multinomial distribution by combining INAR(1) representation with a random effects approach.…

  10. A New Class of Pandiagonal Squares

    ERIC Educational Resources Information Center

    Loly, P. D.; Steeds, M. J.

    2005-01-01

    An interesting class of purely pandiagonal, i.e. non-magic, whole number (integer) squares of orders (row/column dimension) of the powers of two which are related to Gray codes and square Karnaugh maps has been identified. Treated as matrices these squares possess just two non-zero eigenvalues. The construction of these squares has been automated…

  11. A hybrid inventory management system respondingto regular demand and surge demand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohammad S. Roni; Mingzhou Jin; Sandra D. Eksioglu

    2014-06-01

    This paper proposes a hybrid policy for a stochastic inventory system facing regular demand and surge demand. The combination of two different demand patterns can be observed in many areas, such as healthcare inventory and humanitarian supply chain management. The surge demand has a lower arrival rate but higher demand volume per arrival. The solution approach proposed in this paper incorporates the level crossing method and mixed integer programming technique to optimize the hybrid inventory policy with both regular orders and emergency orders. The level crossing method is applied to obtain the equilibrium distributions of inventory levels under a givenmore » policy. The model is further transformed into a mixed integer program to identify an optimal hybrid policy. A sensitivity analysis is conducted to investigate the impact of parameters on the optimal inventory policy and minimum cost. Numerical results clearly show the benefit of using the proposed hybrid inventory model. The model and solution approach could help healthcare providers or humanitarian logistics providers in managing their emergency supplies in responding to surge demands.« less

  12. Polynomial sequences for bond percolation critical thresholds

    DOE PAGES

    Scullard, Christian R.

    2011-09-22

    In this paper, I compute the inhomogeneous (multi-probability) bond critical surfaces for the (4, 6, 12) and (3 4, 6) using the linearity approximation described in (Scullard and Ziff, J. Stat. Mech. 03021), implemented as a branching process of lattices. I find the estimates for the bond percolation thresholds, pc(4, 6, 12) = 0.69377849... and p c(3 4, 6) = 0.43437077..., compared with Parviainen’s numerical results of p c = 0.69373383... and p c = 0.43430621... . These deviations are of the order 10 -5, as is standard for this method. Deriving thresholds in this way for a given latticemore » leads to a polynomial with integer coefficients, the root in [0, 1] of which gives the estimate for the bond threshold and I show how the method can be refined, leading to a series of higher order polynomials making predictions that likely converge to the exact answer. Finally, I discuss how this fact hints that for certain graphs, such as the kagome lattice, the exact bond threshold may not be the root of any polynomial with integer coefficients.« less

  13. Developing project initiation documents : a survey of state practice.

    DOT National Transportation Integrated Search

    2011-12-01

    Caltrans is performing an assessment of its project initiation document (PID) program in response to findings and : recommendations provided by the Legislative Analysts Office (LAO) in its February 2009 annual budget report. : PIDs are highway pro...

  14. An accurate computational method for the diffusion regime verification

    NASA Astrophysics Data System (ADS)

    Zhokh, Alexey A.; Strizhak, Peter E.

    2018-04-01

    The diffusion regime (sub-diffusive, standard, or super-diffusive) is defined by the order of the derivative in the corresponding transport equation. We develop an accurate computational method for the direct estimation of the diffusion regime. The method is based on the derivative order estimation using the asymptotic analytic solutions of the diffusion equation with the integer order and the time-fractional derivatives. The robustness and the computational cheapness of the proposed method are verified using the experimental methane and methyl alcohol transport kinetics through the catalyst pellet.

  15. Inverse optimal self-tuning PID control design for an autonomous underwater vehicle

    NASA Astrophysics Data System (ADS)

    Rout, Raja; Subudhi, Bidyadhar

    2017-01-01

    This paper presents a new approach to path following control design for an autonomous underwater vehicle (AUV). A NARMAX model of the AUV is derived first and then its parameters are adapted online using the recursive extended least square algorithm. An adaptive Propotional-Integral-Derivative (PID) controller is developed using the derived parameters to accomplish the path following task of an AUV. The gain parameters of the PID controller are tuned using an inverse optimal control technique, which alleviates the problem of solving Hamilton-Jacobian equation and also satisfies an error cost function. Simulation studies were pursued to verify the efficacy of the proposed control algorithm. From the obtained results, it is envisaged that the proposed NARMAX model-based self-tuning adaptive PID control provides good path following performance even in the presence of uncertainty arising due to ocean current or hydrodynamic parameter.

  16. PID self tuning control based on Mamdani fuzzy logic control for quadrotor stabilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Priyambodo, Tri Kuntoro, E-mail: mastri@ugm.ac.id; Putra, Agfianto Eko; Department of Computer Science and Electronics, Universitas Gadjah Mada, Yogyakarta

    Quadrotor as one type of UAV have the ability to perform Vertical Take Off and Landing (VTOL). It allows the Quadrotor to be stationary hovering in the air. PID (Proportional Integral Derivative) control system is one of the control methods that are commonly used. It is usually used to optimize the Quadrotor stabilization at least based on the three Eulerian angles (roll, pitch, and yaw) as input parameters for the control system. The three constants of PID can be obtained in various methods. The simplest method is tuning manually. This method has several weaknesses. For example if the three constantsmore » are not exact, the resulting response will deviate from the desired result. By combining the methods of PID with fuzzy logic systems where human expertise is implemented into the machine language is expected to further optimize the control system.« less

  17. Modeling and simulation of permanent magnet synchronous motor based on neural network control strategy

    NASA Astrophysics Data System (ADS)

    Luo, Bingyang; Chi, Shangjie; Fang, Man; Li, Mengchao

    2017-03-01

    Permanent magnet synchronous motor is used widely in industry, the performance requirements wouldn't be met by adopting traditional PID control in some of the occasions with high requirements. In this paper, a hybrid control strategy - nonlinear neural network PID and traditional PID parallel control are adopted. The high stability and reliability of traditional PID was combined with the strong adaptive ability and robustness of neural network. The permanent magnet synchronous motor will get better control performance when switch different working modes according to different controlled object conditions. As the results showed, the speed response adopting the composite control strategy in this paper was faster than the single control strategy. And in the case of sudden disturbance, the recovery time adopting the composite control strategy designed in this paper was shorter, the recovery ability and the robustness were stronger.

  18. Nonlinear Adaptive PID Control for Greenhouse Environment Based on RBF Network

    PubMed Central

    Zeng, Songwei; Hu, Haigen; Xu, Lihong; Li, Guanghui

    2012-01-01

    This paper presents a hybrid control strategy, combining Radial Basis Function (RBF) network with conventional proportional, integral, and derivative (PID) controllers, for the greenhouse climate control. A model of nonlinear conservation laws of enthalpy and matter between numerous system variables affecting the greenhouse climate is formulated. RBF network is used to tune and identify all PID gain parameters online and adaptively. The presented Neuro-PID control scheme is validated through simulations of set-point tracking and disturbance rejection. We compare the proposed adaptive online tuning method with the offline tuning scheme that employs Genetic Algorithm (GA) to search the optimal gain parameters. The results show that the proposed strategy has good adaptability, strong robustness and real-time performance while achieving satisfactory control performance for the complex and nonlinear greenhouse climate control system, and it may provide a valuable reference to formulate environmental control strategies for actual application in greenhouse production. PMID:22778587

  19. IESIP - AN IMPROVED EXPLORATORY SEARCH TECHNIQUE FOR PURE INTEGER LINEAR PROGRAMMING PROBLEMS

    NASA Technical Reports Server (NTRS)

    Fogle, F. R.

    1994-01-01

    IESIP, an Improved Exploratory Search Technique for Pure Integer Linear Programming Problems, addresses the problem of optimizing an objective function of one or more variables subject to a set of confining functions or constraints by a method called discrete optimization or integer programming. Integer programming is based on a specific form of the general linear programming problem in which all variables in the objective function and all variables in the constraints are integers. While more difficult, integer programming is required for accuracy when modeling systems with small numbers of components such as the distribution of goods, machine scheduling, and production scheduling. IESIP establishes a new methodology for solving pure integer programming problems by utilizing a modified version of the univariate exploratory move developed by Robert Hooke and T.A. Jeeves. IESIP also takes some of its technique from the greedy procedure and the idea of unit neighborhoods. A rounding scheme uses the continuous solution found by traditional methods (simplex or other suitable technique) and creates a feasible integer starting point. The Hook and Jeeves exploratory search is modified to accommodate integers and constraints and is then employed to determine an optimal integer solution from the feasible starting solution. The user-friendly IESIP allows for rapid solution of problems up to 10 variables in size (limited by DOS allocation). Sample problems compare IESIP solutions with the traditional branch-and-bound approach. IESIP is written in Borland's TURBO Pascal for IBM PC series computers and compatibles running DOS. Source code and an executable are provided. The main memory requirement for execution is 25K. This program is available on a 5.25 inch 360K MS DOS format diskette. IESIP was developed in 1990. IBM is a trademark of International Business Machines. TURBO Pascal is registered by Borland International.

  20. Sums of Consecutive Integers

    ERIC Educational Resources Information Center

    Pong, Wai Yan

    2007-01-01

    We begin by answering the question, "Which natural numbers are sums of consecutive integers?" We then go on to explore the set of lengths (numbers of summands) in the decompositions of an integer as such sums.

  1. Music algorithm for imaging of a sound-hard arc in limited-view inverse scattering problem

    NASA Astrophysics Data System (ADS)

    Park, Won-Kwang

    2017-07-01

    MUltiple SIgnal Classification (MUSIC) algorithm for a non-iterative imaging of sound-hard arc in limited-view inverse scattering problem is considered. In order to discover mathematical structure of MUSIC, we derive a relationship between MUSIC and an infinite series of Bessel functions of integer order. This structure enables us to examine some properties of MUSIC in limited-view problem. Numerical simulations are performed to support the identified structure of MUSIC.

  2. The natural history of Chlamydia trachomatis infection in women: a multi-parameter evidence synthesis.

    PubMed

    Price, Malcolm J; Ades, A E; Soldan, Kate; Welton, Nicky J; Macleod, John; Simms, Ian; DeAngelis, Daniela; Turner, Katherine Me; Horner, Paddy J

    2016-03-01

    The evidence base supporting the National Chlamydia Screening Programme, initiated in 2003, has been questioned repeatedly, with little consensus on modelling assumptions, parameter values or evidence sources to be used in cost-effectiveness analyses. The purpose of this project was to assemble all available evidence on the prevalence and incidence of Chlamydia trachomatis (CT) in the UK and its sequelae, pelvic inflammatory disease (PID), ectopic pregnancy (EP) and tubal factor infertility (TFI) to review the evidence base in its entirety, assess its consistency and, if possible, arrive at a coherent set of estimates consistent with all the evidence. Evidence was identified using 'high-yield' strategies. Bayesian Multi-Parameter Evidence Synthesis models were constructed for separate subparts of the clinical and population epidemiology of CT. Where possible, different types of data sources were statistically combined to derive coherent estimates. Where evidence was inconsistent, evidence sources were re-interpreted and new estimates derived on a post-hoc basis. An internally coherent set of estimates was generated, consistent with a multifaceted evidence base, fertility surveys and routine UK statistics on PID and EP. Among the key findings were that the risk of PID (symptomatic or asymptomatic) following an untreated CT infection is 17.1% [95% credible interval (CrI) 6% to 29%] and the risk of salpingitis is 7.3% (95% CrI 2.2% to 14.0%). In women aged 16-24 years, screened at annual intervals, at best, 61% (95% CrI 55% to 67%) of CT-related PID and 22% (95% CrI 7% to 43%) of all PID could be directly prevented. For women aged 16-44 years, the proportions of PID, EP and TFI that are attributable to CT are estimated to be 20% (95% CrI 6% to 38%), 4.9% (95% CrI 1.2% to 12%) and 29% (95% CrI 9% to 56%), respectively. The prevalence of TFI in the UK in women at the end of their reproductive lives is 1.1%: this is consistent with all PID carrying a relatively high risk of reproductive damage, whether diagnosed or not. Every 1000 CT infections in women aged 16-44 years, on average, gives rise to approximately 171 episodes of PID and 73 of salpingitis, 2.0 EPs and 5.1 women with TFI at age 44 years. The study establishes a set of interpretations of the major studies and study designs, under which a coherent set of estimates can be generated. CT is a significant cause of PID and TFI. CT screening is of benefit to the individual, but detection and treatment of incident infection may be more beneficial. Women with lower abdominal pain need better advice on when to seek early medical attention to avoid risk of reproductive damage. The study provides new insights into the reproductive risks of PID and the role of CT. Further research is required on the proportions of PID, EP and TFI attributable to CT to confirm predictions made in this report, and to improve the precision of key estimates. The cost-effectiveness of screening should be re-evaluated using the findings of this report. The Medical Research Council grant G0801947.

  3. A second-order accurate immersed boundary-lattice Boltzmann method for particle-laden flows

    NASA Astrophysics Data System (ADS)

    Zhou, Qiang; Fan, Liang-Shih

    2014-07-01

    A new immersed boundary-lattice Boltzmann method (IB-LBM) is presented for fully resolved simulations of incompressible viscous flows laden with rigid particles. The immersed boundary method (IBM) recently developed by Breugem (2012) [19] is adopted in the present method, development including the retraction technique, the multi-direct forcing method and the direct account of the inertia of the fluid contained within the particles. The present IB-LBM is, however, formulated with further improvement with the implementation of the high-order Runge-Kutta schemes in the coupled fluid-particle interaction. The major challenge to implement high-order Runge-Kutta schemes in the LBM is that the flow information such as density and velocity cannot be directly obtained at a fractional time step from the LBM since the LBM only provides the flow information at an integer time step. This challenge can be, however, overcome as given in the present IB-LBM by extrapolating the flow field around particles from the known flow field at the previous integer time step. The newly calculated fluid-particle interactions from the previous fractional time steps of the current integer time step are also accounted for in the extrapolation. The IB-LBM with high-order Runge-Kutta schemes developed in this study is validated by several benchmark applications. It is demonstrated, for the first time, that the IB-LBM has the capacity to resolve the translational and rotational motion of particles with the second-order accuracy. The optimal retraction distances for spheres and tubes that help the method achieve the second-order accuracy are found to be around 0.30 and -0.47 times of the lattice spacing, respectively. Simulations of the Stokes flow through a simple cubic lattice of rotational spheres indicate that the lift force produced by the Magnus effect can be very significant in view of the magnitude of the drag force when the practical rotating speed of the spheres is encountered. This finding may lead to more comprehensive studies of the effect of the particle rotation on fluid-solid drag laws. It is also demonstrated that, when the third-order or the fourth-order Runge-Kutta scheme is used, the numerical stability of the present IB-LBM is better than that of all methods in the literature, including the previous IB-LBMs and also the methods with the combination of the IBM and the traditional incompressible Navier-Stokes solver.

  4. On the convergence between PSY-5 domains and PID-5 domains and facets: implications for assessment of DSM-5 personality traits.

    PubMed

    Anderson, Jaime L; Sellbom, Martin; Bagby, R Michael; Quilty, Lena C; Veltri, Carlo O C; Markon, Kristian E; Krueger, Robert F

    2013-06-01

    The DSM-5 Personality and Personality Disorders workgroup and their consultants have developed the 220-item, self-report Personality Inventory for the DSM-5 (PID-5) for direct assessment of the proposed personality trait system for DSM-5; however, most practicing clinical psychologists will likely continue to rely on separate omnibus measures to index symptoms and traits associated with psychopathology. The Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF) is one such measure and assesses the Personality Psychopathology Five (PSY-5) domains, which are conceptual cognates of the DSM-5 trait domains. The current study examined the associations between the MMPI-2-RF PSY-5 scales and the DSM-5 trait domains and facets indexed by the PID-5. A clear pattern of convergence was found indicating that each of the PSY-5 scales was most highly correlated with its conceptually expected PID-5 counterpart (rs = .44-.67; Mdn r = .53) and facet correlations generally showed the same pattern. Similarly, when each of the PSY-5 scales was regressed onto the PID-5 domains, the conceptually expected pattern of associations emerged even more clearly. Finally, a joint exploratory factor analysis with the PSY-5 and PID-5 trait facet scales indicated a five-factor solution that clearly resembled both of the PSY-5/DSM-5 trait domains. These results show clear evidence that the MMPI-2-RF has utility in the assessment of dimensional personality traits proposed for the upcoming DSM-5.

  5. Susceptibility of white-tailed deer (Odocoileus virginianus) to experimental infection with epizootic hemorrhagic disease virus serotype 7.

    PubMed

    Ruder, Mark G; Allison, Andrew B; Stallknecht, David E; Mead, Daniel G; McGraw, Sabrina M; Carter, Deborah L; Kubiski, Steven V; Batten, Carrie A; Klement, Eyal; Howerth, Elizabeth W

    2012-07-01

    During the fall of 2006, in Israel, epizootic hemorrhagic disease virus (EHDV) serotype 7 caused an intense and widespread epizootic in domestic cattle that resulted in significant economic losses for the dairy industry. The susceptibility of potential North American vector and ruminant hosts to infection with EHDV-7 is not known but is essential to understanding the potential for establishment of this exotic orbivirus in North America if it were introduced. Our primary objective was to determine whether white-tailed deer (WTD; Odocoileus virginianus) are susceptible to infection with EHDV-7. Six, 8-mo-old WTD were experimentally infected with EHDV-7, and all became infected and exhibited varying degrees of clinical disease. Clinical signs, clinicopathologic abnormalities, and postmortem findings were consistent with previous reports of orbiviral hemorrhagic disease (HD) in this species. Four of six animals died or were euthanized because of the severity of disease, one on postinoculation day (PID) 5 and the remaining WTD on PID 7. All deer had detectable viremia on PID 3, which peaked on PID 5 or 6 and persisted for as long as PID 46 in one animal. Deer surviving the acute phase of the disease seroconverted by PID 10. Based on the 67% mortality rate we observed, this strain of EHDV-7 is virulent in WTD, reaffirming their role as a sentinel species for the detection of endemic and nonendemic EHDV. Further, the observed disease was indistinguishable from previous reports of disease caused by North American EHDV and bluetongue virus serotypes, highlighting the importance of serotype-specific diagnostics during suspected HD outbreaks.

  6. Untangling therapeutic ingredients of a personalized intervention for patients with depression and severe COPD.

    PubMed

    Alexopoulos, George S; Kiosses, Dimitris N; Sirey, Jo Anne; Kanellopoulos, Dora; Seirup, Joanna K; Novitch, Richard S; Ghosh, Samiran; Banerjee, Samprit; Raue, Patrick J

    2014-11-01

    We developed a personalized intervention for depressed patients with COPD (PID-C) aimed to mobilize patients to participate in the care of both conditions. We showed that PID-C reduced depressive symptoms and dyspnea-related disability more than usual care over 28 weeks. This study focused on untangling key therapeutic ingredients of PID-C. Randomized controlled trial. Community. 138 patients who received the diagnoses of COPD and major depression after screening 898 consecutive admissions for acute inpatient pulmonary rehabilitation. Nine sessions of PID-C compared with usual care over 28 weeks. Primary outcome measures were the 17-item Hamilton Depression Rating Scale and the Pulmonary Functional Status and Dyspnea Questionnaire-Modified. Other measures were adherence to rehabilitation exercise (≥2 hours per week) and adherence to adequate antidepressant prescriptions. Low severity of dyspnea-related disability and adherence to antidepressants predicted subsequent improvement of depression. Exercise and low depression severity predicted improvement of dyspnea-related disability. PID-C led to an interacting spiral of improvement in both depression and disability in a gravely medically ill population with a 17% mortality rate over 28 weeks and an expected deterioration in disability. The interrelationship of the course of depression and dyspnea-related disability underscores the need to target adherence to both antidepressants and chronic obstructive pulmonary disease rehabilitation. PID-C may serve as a care management model for depressed persons suffering from medical illnesses with a deteriorating course. Copyright © 2014 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  7. Near-infrared diffuse reflectance imaging of infarct core and peri-infarct depolarization in a rat middle cerebral artery occlusion model

    NASA Astrophysics Data System (ADS)

    Kawauchi, Satoko; Nishidate, Izumi; Nawashiro, Hiroshi; Sato, Shunichi

    2014-03-01

    To understand the pathophysiology of ischemic stroke, in vivo imaging of the brain tissue viability and related spreading depolarization is crucial. In the infarct core, impairment of energy metabolism causes anoxic depolarization (AD), which considerably increases energy consumption, accelerating irreversible neuronal damage. In the peri-infarct penumbra region, where tissue is still reversible despite limited blood flow, peri-infarct depolarization (PID) occurs, exacerbating energy deficit and hence expanding the infarct area. We previously showed that light-scattering signal, which is sensitive to cellular/subcellular structural integrity, was correlated with AD and brain tissue viability in a rat hypoxia-reoxygenation model. In the present study, we performed transcranial NIR diffuse reflectance imaging of the rat brain during middle cerebral artery (MCA) occlusion and examined whether the infarct core and PIDs can be detected. Immediately after occluding the left MCA, light scattering started to increase focally in the occlusion site and a bright region was generated near the occlusion site and spread over the left entire cortex, which was followed by a dark region, showing the occurrence of PID. The PID was generated repetitively and the number of times of occurrence in a rat ranged from four to ten within 1 hour after occlusion (n=4). The scattering increase in the occlusion site was irreversible and the area with increased scattering expanded with increasing the number of PIDs, indicating an expansion of the infarct core. These results suggest the usefulness of NIR diffuse reflectance signal to visualize spatiotemporal changes in the infarct area and PIDs.

  8. Adoptive Immunotherapy for Primary Immunodeficiency Disorders with Virus-Specific T-lymphocytes

    PubMed Central

    Naik, Swati; Nicholas, Sarah K; Martinez, Caridad A; Leen, Ann M; Hanley, Patrick J; Gottschalk, Steven M; Rooney, Cliona M; Hanson, I Celine; Krance, Robert A; Cruz, Conrad R; Amrolia, Persis; Lucchini, Giovanna; Bunin, Nancy; Heimall, Jennifer; Klein, Orly R; Gennery, Andrew R; Slatter, Mary A; Vickers, Mark A; Orange, Jordan S; Heslop, Helen E; Bollard, Catherine M; Keller, Michael D

    2016-01-01

    Background Viral infections are a leading fatal complication for patients with primary immunodeficiency (PID) who require hematopoietic stem cell transplantation (HSCT). Use of virus-specific T-lymphocytes (VST) has been successful for treatment and prevention of viral infections after HSCT for malignant and non-malignant conditions. Here, we describe the clinical use of VST in PID at four centers. Objective To evaluate the safety and efficacy of VST for treatment of viral infections in patients with PID. Methods Patients with PID who have received VST therapy on previous or current protocols were reviewed in aggregate. Clinical information including transplantation details, viral infections, and use of antiviral and immunosuppressive pharmacotherapy were evaluated. Data regarding VST production, infusions, and adverse reactions were compared. Results Thirty-six patients with twelve classes of PID diagnoses received 37 VST products before or after HSCT. Twenty-six patients (72%) had been diagnosed with infections with cytomegalovirus, Epstein-Barr virus, adenovirus, BK virus, and/or human herpesvirus 6 (HHV6). Two patients were treated prior to HSCT due to EBV-associated lymphoproliferative disease (LPD). Partial or complete responses against targeted viruses occurred in 81% of patients overall. Time to response varied from two weeks to three months (median 28 days). Overall survival at six months after therapy was 80%. Four patients developed graft versus host disease (GVHD) in the 45 days following VST infusion, which in most cases was therapy-responsive. Interpretation VST derived from either stem cell donors or third-party donors are likely safe and effective for treatment of viral infections in patients with PID. PMID:26920464

  9. Evaluation of the Safety, Tolerability, and Pharmacokinetics of Gammaplex® 10% Versus Gammaplex® 5% in Subjects with Primary Immunodeficiency.

    PubMed

    Wasserman, Richard L; Melamed, Isaac R; Stein, Mark R; Jolles, Stephen; Norton, Miranda; Moy, James N

    2017-04-01

    This phase 3, multicenter, open-label, randomized, two-period, crossover bioequivalence trial evaluated the safety, tolerability, and pharmacokinetics of intravenous immunoglobulins (IVIGs) Gammaplex 5% and Gammaplex 10% in 33 adults and 15 children with primary immunodeficiency diseases (PIDs). Eligible adults received five Gammaplex 5% infusions followed by five Gammaplex 10% infusions, or vice versa, stratified by a 21- or 28-day dosing regimen. Pediatric subjects received five Gammaplex 10% infusions only. The primary objective, to demonstrate the bioequivalence of Gammaplex 10% and Gammaplex 5% at the 28-day dosing interval, was met based on the Gammaplex 10%/Gammaplex 5% ratio of area under the concentration versus time curve (AUC 0-28 ) values. Throughout the study, total immunoglobulin G trough levels were well maintained, with total values generally ≥600 mg/dL (minimum level for study inclusion). At the dosing schedules and infusion rates used in this study, safety and tolerability were comparable and acceptable in adult and pediatric PID subjects treated with Gammaplex 10% and 5%. In this study, the first direct comparison of 5% IVIG and 10% IVIG products in PID subjects, the pharmacokinetic analysis demonstrated bioequivalence of Gammaplex 10% and Gammaplex 5% at the 28-day dosing interval. The Gammaplex 10% formulation was safe and well tolerated in pediatric and adult PID subjects. Based on the results from this bridging study in PID subjects, Gammaplex 10% could be expected to have a therapeutic effect similar to the licensed Gammaplex 5%, which has demonstrated efficacy and tolerability in patients with PID and idiopathic thrombocytopenic purpura.

  10. Primary Immunodeficiency Diseases in Highly Consanguineous Populations from Middle East and North Africa: Epidemiology, Diagnosis, and Care

    PubMed Central

    Al-Mousa, Hamoud; Al-Saud, Bandar

    2017-01-01

    Middle East and North Africa region (MENA)1 populations are of different ethnic origins. Consanguineous marriages are common practice with an overall incidence ranging between 20 and 50%. Primary immunodeficiency diseases (PIDs) are a group of heterogeneous genetic disorders caused by defects in the immune system that predisposes patients to recurrent infections, autoimmune diseases, and malignancies. PIDs are more common in areas with high rates of consanguineous marriage since most have an autosomal recessive mode of inheritance. Studies of PIDs in the region had contributed into the discovery and the understanding of several novel immunodeficiency disorders. Few MENA countries have established national registries that helped in estimating the prevalence and defining common PID phenotypes. Available reports from those registries suggest a predominance of combined immunodeficiency disorders in comparison to antibody deficiencies seen in other populations. Access to a comprehensive clinical immunology management services is limited in most MENA countries. Few countries had established advanced clinical immunology service, capable to provide extensive genetic testing and stem cell transplantation for various immunodeficiency disorders. Newborn screening for PIDs is an essential need in this population considering the high incidence of illness and can be implemented and incorporated into existing newborn screening programs in some MENA countries. Increased awareness, subspecialty training in clinical immunology, and establishing collaborating research centers are necessary to improve patient care. In this review, we highlight some of the available epidemiological data, challenges in establishing diagnosis, and available therapy for PID patients in the region. PMID:28694805

  11. Randomized Crossover Comparison of Personalized MPC and PID Control Algorithms for the Artificial Pancreas

    PubMed Central

    Pinsker, Jordan E.; Lee, Joon Bok; Dassau, Eyal; Seborg, Dale E.; Bradley, Paige K.; Gondhalekar, Ravi; Bevier, Wendy C.; Huyett, Lauren; Zisser, Howard C.; Doyle, Francis J.

    2016-01-01

    OBJECTIVE To evaluate two widely used control algorithms for an artificial pancreas (AP) under nonideal but comparable clinical conditions. RESEARCH DESIGN AND METHODS After a pilot safety and feasibility study (n = 10), closed-loop control (CLC) was evaluated in a randomized, crossover trial of 20 additional adults with type 1 diabetes. Personalized model predictive control (MPC) and proportional integral derivative (PID) algorithms were compared in supervised 27.5-h CLC sessions. Challenges included overnight control after a 65-g dinner, response to a 50-g breakfast, and response to an unannounced 65-g lunch. Boluses of announced dinner and breakfast meals were given at mealtime. The primary outcome was time in glucose range 70–180 mg/dL. RESULTS Mean time in range 70–180 mg/dL was greater for MPC than for PID (74.4 vs. 63.7%, P = 0.020). Mean glucose was also lower for MPC than PID during the entire trial duration (138 vs. 160 mg/dL, P = 0.012) and 5 h after the unannounced 65-g meal (181 vs. 220 mg/dL, P = 0.019). There was no significant difference in time with glucose <70 mg/dL throughout the trial period. CONCLUSIONS This first comprehensive study to compare MPC and PID control for the AP indicates that MPC performed particularly well, achieving nearly 75% time in the target range, including the unannounced meal. Although both forms of CLC provided safe and effective glucose management, MPC performed as well or better than PID in all metrics. PMID:27289127

  12. Pelvic Inflammatory Disease

    MedlinePlus

    ... No single step can protect you from every single type of STI. Can women who have sex with women get PID? Yes. ... No single step can protect you from every single type of STI. Can women who have sex with women get PID? Yes. ...

  13. Distributed design approach in persistent identifiers systems

    NASA Astrophysics Data System (ADS)

    Golodoniuc, Pavel; Car, Nicholas; Klump, Jens

    2017-04-01

    The need to identify both digital and physical objects is ubiquitous in our society. Past and present persistent identifier (PID) systems, of which there is a great variety in terms of technical and social implementations, have evolved with the advent of the Internet, which has allowed for globally unique and globally resolvable identifiers. PID systems have catered for identifier uniqueness, integrity, persistence, and trustworthiness, regardless of the identifier's application domain, the scope of which has expanded significantly in the past two decades. Since many PID systems have been largely conceived and developed by small communities, or even a single organisation, they have faced challenges in gaining widespread adoption and, most importantly, the ability to survive change of technology. This has left a legacy of identifiers that still exist and are being used but which have lost their resolution service. We believe that one of the causes of once successful PID systems fading is their reliance on a centralised technical infrastructure or a governing authority. Golodoniuc et al. (2016) proposed an approach to the development of PID systems that combines the use of (a) the Handle system, as a distributed system for the registration and first-degree resolution of persistent identifiers, and (b) the PID Service (Golodoniuc et al., 2015), to enable fine-grained resolution to different information object representations. The proposed approach solved the problem of guaranteed first-degree resolution of identifiers, but left fine-grained resolution and information delivery under the control of a single authoritative source, posing risk to the long-term availability of information resources. Herein, we develop these approaches further and explore the potential of large-scale decentralisation at all levels: (i) persistent identifiers and information resources registration; (ii) identifier resolution; and (iii) data delivery. To achieve large-scale decentralisation, we propose using Distributed Hash Tables (DHT), Peer Exchange networks (PEX), Magnet Links, and peer-to-peer (P2P) file sharing networks - the technologies that enable applications such as BitTorrent (Wu et al., 2010). The proposed approach introduces reliable information replication and caching mechanisms, eliminating the need for a central PID data store, and increases overall system fault tolerance due to the lack of a single point of failure. The proposed PID system's design aims to ensure trustworthiness of the system and incorporates important aspects of governance, such as the notion of the authoritative source, data integrity, caching, and data replication control.

  14. Synchrotron x-ray scattering study of charge-density-wave order in HgBa2CuO4 +δ

    NASA Astrophysics Data System (ADS)

    Tabis, W.; Yu, B.; Bialo, I.; Bluschke, M.; Kolodziej, T.; Kozlowski, A.; Blackburn, E.; Sen, K.; Forgan, E. M.; Zimmermann, M. v.; Tang, Y.; Weschke, E.; Vignolle, B.; Hepting, M.; Gretarsson, H.; Sutarto, R.; He, F.; Le Tacon, M.; Barišić, N.; Yu, G.; Greven, M.

    2017-10-01

    We present a detailed synchrotron x-ray scattering study of the charge-density-wave (CDW) order in simple tetragonal HgBa2CuO4 +δ (Hg1201). Resonant soft x-ray scattering measurements reveal that short-range order appears at a temperature that is distinctly lower than the pseudogap temperature and in excellent agreement with a prior transient reflectivity result. Despite considerable structural differences between Hg1201 and YBa2Cu3O6 +δ , the CDW correlations exhibit similar doping dependencies, and we demonstrate a universal relationship between the CDW wave vector and the size of the reconstructed Fermi pocket observed in quantum oscillation experiments. The CDW correlations in Hg1201 vanish already below optimal doping, once the correlation length is comparable to the CDW modulation period, and they appear to be limited by the disorder potential from unit cells hosting two interstitial oxygen atoms. A complementary hard x-ray diffraction measurement, performed on an underdoped Hg1201 sample in magnetic fields along the crystallographic c axis of up to 16 T, provides information on the form factor of the CDW order. As expected from the single-CuO2-layer structure of Hg1201, the CDW correlations vanish at half-integer values of L and appear to be peaked at integer L . We conclude that the atomic displacements associated with the short-range CDW order are mainly planar, within the CuO2 layers.

  15. Ultra wideband (0.5-16 kHz) MR elastography for robust shear viscoelasticity model identification.

    PubMed

    Liu, Yifei; Yasar, Temel K; Royston, Thomas J

    2014-12-21

    Changes in the viscoelastic parameters of soft biological tissues often correlate with progression of disease, trauma or injury, and response to treatment. Identifying the most appropriate viscoelastic model, then estimating and monitoring the corresponding parameters of that model can improve insight into the underlying tissue structural changes. MR Elastography (MRE) provides a quantitative method of measuring tissue viscoelasticity. In a previous study by the authors (Yasar et al 2013 Magn. Reson. Med. 70 479-89), a silicone-based phantom material was examined over the frequency range of 200 Hz-7.75 kHz using MRE, an unprecedented bandwidth at that time. Six viscoelastic models including four integer order models and two fractional order models, were fit to the wideband viscoelastic data (measured storage and loss moduli as a function of frequency). The 'fractional Voigt' model (spring and springpot in parallel) exhibited the best fit and was even able to fit the entire frequency band well when it was identified based only on a small portion of the band. This paper is an extension of that study with a wider frequency range from 500 Hz to 16 kHz. Furthermore, more fractional order viscoelastic models are added to the comparison pool. It is found that added complexity of the viscoelastic model provides only marginal improvement over the 'fractional Voigt' model. And, again, the fractional order models show significant improvement over integer order viscoelastic models that have as many or more fitting parameters.

  16. Simulation of process identification and controller tuning for flow control system

    NASA Astrophysics Data System (ADS)

    Chew, I. M.; Wong, F.; Bono, A.; Wong, K. I.

    2017-06-01

    PID controller is undeniably the most popular method used in controlling various industrial processes. The feature to tune the three elements in PID has allowed the controller to deal with specific needs of the industrial processes. This paper discusses the three elements of control actions and improving robustness of controllers through combination of these control actions in various forms. A plant model is simulated using the Process Control Simulator in order to evaluate the controller performance. At first, the open loop response of the plant is studied by applying a step input to the plant and collecting the output data from the plant. Then, FOPDT of physical model is formed by using both Matlab-Simulink and PRC method. Then, calculation of controller’s setting is performed to find the values of Kc and τi that will give satisfactory control in closed loop system. Then, the performance analysis of closed loop system is obtained by set point tracking analysis and disturbance rejection performance. To optimize the overall physical system performance, a refined tuning of PID or detuning is further conducted to ensure a consistent resultant output of closed loop system reaction to the set point changes and disturbances to the physical model. As a result, the PB = 100 (%) and τi = 2.0 (s) is preferably chosen for setpoint tracking while PB = 100 (%) and τi = 2.5 (s) is selected for rejecting the imposed disturbance to the model. In a nutshell, selecting correlation tuning values is likewise depended on the required control’s objective for the stability performance of overall physical model.

  17. Information fusion based optimal control for large civil aircraft system.

    PubMed

    Zhen, Ziyang; Jiang, Ju; Wang, Xinhua; Gao, Chen

    2015-03-01

    Wind disturbance has a great influence on landing security of Large Civil Aircraft. Through simulation research and engineering experience, it can be found that PID control is not good enough to solve the problem of restraining the wind disturbance. This paper focuses on anti-wind attitude control for Large Civil Aircraft in landing phase. In order to improve the riding comfort and the flight security, an information fusion based optimal control strategy is presented to restrain the wind in landing phase for maintaining attitudes and airspeed. Data of Boeing707 is used to establish a nonlinear mode with total variables of Large Civil Aircraft, and then two linear models are obtained which are divided into longitudinal and lateral equations. Based on engineering experience, the longitudinal channel adopts PID control and C inner control to keep longitudinal attitude constant, and applies autothrottle system for keeping airspeed constant, while an information fusion based optimal regulator in the lateral control channel is designed to achieve lateral attitude holding. According to information fusion estimation, by fusing hard constraint information of system dynamic equations and the soft constraint information of performance index function, optimal estimation of the control sequence is derived. Based on this, an information fusion state regulator is deduced for discrete time linear system with disturbance. The simulation results of nonlinear model of aircraft indicate that the information fusion optimal control is better than traditional PID control, LQR control and LQR control with integral action, in anti-wind disturbance performance in the landing phase. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Analysis misconception of integers in microteaching activities

    NASA Astrophysics Data System (ADS)

    Setyawati, R. D.; Indiati, I.

    2018-05-01

    This study view to analyse student misconceptions on integers in microteaching activities. This research used qualitative research design. An integers test contained questions from eight main areas of integers. The Integers material test includes (a) converting the image into fractions, (b) examples of positive numbers including rational numbers, (c) operations in fractions, (d) sorting fractions from the largest to the smallest, and vice versa; e) equate denominator, (f) concept of ratio mark, (g) definition of fraction, and (h) difference between fractions and parts. The results indicated an integers concepts: (1) the students have not been able to define concepts well based on the classification of facts in organized part; (2) The correlational concept: students have not been able to combine interrelated events in the form of general principles; and (3) theoretical concepts: students have not been able to use concepts that facilitate in learning the facts or events in an organized system.

  19. Selection of Sustainable Processes using Sustainability ...

    EPA Pesticide Factsheets

    Chemical products can be obtained by process pathways involving varying amounts and types of resources, utilities, and byproduct formation. When such competing process options such as six processes for making methanol as are considered in this study, it is necessary to identify the most sustainable option. Sustainability of a chemical process is generally evaluated with indicators that require process and chemical property data. These indicators individually reflect the impacts of the process on areas of sustainability, such as the environment or society. In order to choose among several alternative processes an overall comparative analysis is essential. Generally net profit will show the most economic process. A mixed integer optimization problem can also be solved to identify the most economic among competing processes. This method uses economic optimization and leaves aside the environmental and societal impacts. To make a decision on the most sustainable process, the method presented here rationally aggregates the sustainability indicators into a single index called sustainability footprint (De). Process flow and economic data were used to compute the indicator values. Results from sustainability footprint (De) are compared with those from solving a mixed integer optimization problem. In order to identify the rank order of importance of the indicators, a multivariate analysis is performed using partial least square variable importance in projection (PLS-VIP)

  20. Multi-Item Multiperiodic Inventory Control Problem with Variable Demand and Discounts: A Particle Swarm Optimization Algorithm

    PubMed Central

    Mousavi, Seyed Mohsen; Niaki, S. T. A.; Bahreininejad, Ardeshir; Musa, Siti Nurmaya

    2014-01-01

    A multi-item multiperiod inventory control model is developed for known-deterministic variable demands under limited available budget. Assuming the order quantity is more than the shortage quantity in each period, the shortage in combination of backorder and lost sale is considered. The orders are placed in batch sizes and the decision variables are assumed integer. Moreover, all unit discounts for a number of products and incremental quantity discount for some other items are considered. While the objectives are to minimize both the total inventory cost and the required storage space, the model is formulated into a fuzzy multicriteria decision making (FMCDM) framework and is shown to be a mixed integer nonlinear programming type. In order to solve the model, a multiobjective particle swarm optimization (MOPSO) approach is applied. A set of compromise solution including optimum and near optimum ones via MOPSO has been derived for some numerical illustration, where the results are compared with those obtained using a weighting approach. To assess the efficiency of the proposed MOPSO, the model is solved using multi-objective genetic algorithm (MOGA) as well. A large number of numerical examples are generated at the end, where graphical and statistical approaches show more efficiency of MOPSO compared with MOGA. PMID:25093195

  1. Fractional Modeling of the AC Large-Signal Frequency Response in Magnetoresistive Current Sensors

    PubMed Central

    Arias, Sergio Iván Ravello; Muñoz, Diego Ramírez; Moreno, Jaime Sánchez; Cardoso, Susana; Ferreira, Ricardo; de Freitas, Paulo Jorge Peixeiro

    2013-01-01

    Fractional calculus is considered when derivatives and integrals of non-integer order are applied over a specific function. In the electrical and electronic domain, the transfer function dependence of a fractional filter not only by the filter order n, but additionally, of the fractional order α is an example of a great number of systems where its input-output behavior could be more exactly modeled by a fractional behavior. Following this aim, the present work shows the experimental ac large-signal frequency response of a family of electrical current sensors based in different spintronic conduction mechanisms. Using an ac characterization set-up the sensor transimpedance function Zt(if) is obtained considering it as the relationship between sensor output voltage and input sensing current, Zt(jf)=Vo,sensor(jf)/Isensor(jf). The study has been extended to various magnetoresistance sensors based in different technologies like anisotropic magnetoresistance (AMR), giant magnetoresistance (GMR), spin-valve (GMR-SV) and tunnel magnetoresistance (TMR). The resulting modeling shows two predominant behaviors, the low-pass and the inverse low-pass with fractional index different from the classical integer response. The TMR technology with internal magnetization offers the best dynamic and sensitivity properties opening the way to develop actual industrial applications. PMID:24351648

  2. Sixth-grade students' reasoning on the order relation of integers as influenced by prior experience: an inferentialist analysis

    NASA Astrophysics Data System (ADS)

    Schindler, Maike; Hußmann, Stephan; Nilsson, Per; Bakker, Arthur

    2017-12-01

    Negative numbers are among the first formalizations students encounter in their mathematics learning that clearly differ from out-of-school experiences. What has not sufficiently been addressed in previous research is the question of how students draw on their prior experiences when reasoning on negative numbers and how they infer from these experiences. This article presents results from an empirical study investigating sixth-grade students' reasoning and inferring from school-based and out-of-school experiences. In particular, it addresses the order relation, which deals with students' very first encounters with negative numbers. Here, students can reason in different ways, depending on the experiences they draw on. We study how students reason before a lesson series and how their reasoning is influenced through this lesson series where the number line and the context debts-and-assets are predominant. For grasping the reasoning's inferential and social nature and conducting in-depth analyses of two students' reasoning, we use an epistemological framework that is based on the philosophical theory of inferentialism. The results illustrate how the students infer their reasoning from out-of-school and from school-based experiences both before and after the lesson series. They reveal interesting phenomena not previously analyzed in the research on the order relation for integers.

  3. Microwave spectroscopic observation of distinct electron solid phases in wide quantum wells

    NASA Astrophysics Data System (ADS)

    Hatke, A. T.; Liu, Yang; Magill, B. A.; Moon, B. H.; Engel, L. W.; Shayegan, M.; Pfeiffer, L. N.; West, K. W.; Baldwin, K. W.

    2014-06-01

    In high magnetic fields, two-dimensional electron systems can form a number of phases in which interelectron repulsion plays the central role, since the kinetic energy is frozen out by Landau quantization. These phases include the well-known liquids of the fractional quantum Hall effect, as well as solid phases with broken spatial symmetry and crystalline order. Solids can occur at the low Landau-filling termination of the fractional quantum Hall effect series but also within integer quantum Hall effects. Here we present microwave spectroscopy studies of wide quantum wells that clearly reveal two distinct solid phases, hidden within what in d.c. transport would be the zero diagonal conductivity of an integer quantum-Hall-effect state. Explanation of these solids is not possible with the simple picture of a Wigner solid of ordinary (quasi) electrons or holes.

  4. Chromosome structures: reduction of certain problems with unequal gene content and gene paralogs to integer linear programming.

    PubMed

    Lyubetsky, Vassily; Gershgorin, Roman; Gorbunov, Konstantin

    2017-12-06

    Chromosome structure is a very limited model of the genome including the information about its chromosomes such as their linear or circular organization, the order of genes on them, and the DNA strand encoding a gene. Gene lengths, nucleotide composition, and intergenic regions are ignored. Although highly incomplete, such structure can be used in many cases, e.g., to reconstruct phylogeny and evolutionary events, to identify gene synteny, regulatory elements and promoters (considering highly conserved elements), etc. Three problems are considered; all assume unequal gene content and the presence of gene paralogs. The distance problem is to determine the minimum number of operations required to transform one chromosome structure into another and the corresponding transformation itself including the identification of paralogs in two structures. We use the DCJ model which is one of the most studied combinatorial rearrangement models. Double-, sesqui-, and single-operations as well as deletion and insertion of a chromosome region are considered in the model; the single ones comprise cut and join. In the reconstruction problem, a phylogenetic tree with chromosome structures in the leaves is given. It is necessary to assign the structures to inner nodes of the tree to minimize the sum of distances between terminal structures of each edge and to identify the mutual paralogs in a fairly large set of structures. A linear algorithm is known for the distance problem without paralogs, while the presence of paralogs makes it NP-hard. If paralogs are allowed but the insertion and deletion operations are missing (and special constraints are imposed), the reduction of the distance problem to integer linear programming is known. Apparently, the reconstruction problem is NP-hard even in the absence of paralogs. The problem of contigs is to find the optimal arrangements for each given set of contigs, which also includes the mutual identification of paralogs. We proved that these problems can be reduced to integer linear programming formulations, which allows an algorithm to redefine the problems to implement a very special case of the integer linear programming tool. The results were tested on synthetic and biological samples. Three well-known problems were reduced to a very special case of integer linear programming, which is a new method of their solutions. Integer linear programming is clearly among the main computational methods and, as generally accepted, is fast on average; in particular, computation systems specifically targeted at it are available. The challenges are to reduce the size of the corresponding integer linear programming formulations and to incorporate a more detailed biological concept in our model of the reconstruction.

  5. Blood cultures for women hospitalized with acute pelvic inflammatory disease. Are they necessary?

    PubMed

    Apuzzio, J J; Hessami, S; Rodriguez, P

    2001-09-01

    To determine the incidence of positive blood cultures and if the results affect the clinical management or the duration of hospital stay in patients with acute pelvic inflammatory disease (PID). Retrospective study of all patients hospitalized with a diagnosis of acute PID from January 1, 1996, to December 31, 1997. Of 93 patients in the study, 3 had significant bacterial growth from blood culture specimens. The results of blood culture specimens did not affect clinical management. Routine specimens for blood culture may not be needed from patients hospitalized with acute PID.

  6. Consanguinity and primary immunodeficiencies.

    PubMed

    Al-Herz, Waleed; Aldhekri, Hasan; Barbouche, Mohamed-Ridha; Rezaei, Nima

    2014-01-01

    Primary immunodeficiencies (PIDs) are a heterogeneous group of genetic disorders caused by defects in the immune system that predispose patients to infections, autoimmune diseases, lymphoproliferation and malignancies. Most PIDs are inherited in an autosomal recessive pattern; therefore, they are more common in areas with high rates of consanguineous marriage. Reports about PIDs from these areas have demonstrated a peculiar prevalence of more severe forms of diseases compared to other regions, and patients born to consanguineous parents have increased rates of morbidity and mortality compared to other patients. Individuals at high risk of having a child with a PID who wish to have a healthy child have limited options, these include prenatal diagnosis and pre-implantation genetic diagnosis. However, these options require a collaborative team of specialists and may not always be implemented due to geographic, religious, financial or social factors. The recent introduction of newborn-screening programs for a number of T and B lymphocyte deficiencies will facilitate early diagnosis and therapeutic interventions, which may include hematopoietic stem cell transplantation and intravenous immunoglobulin treatment. There is a need for the implementation of strategies to increase public awareness of the health risks associated with consanguineous marriage. It should be stressed that genetic counseling should be an important component of the care of patients with PIDs as well as their families. © 2014 S. Karger AG, Basel.

  7. The psychometric properties of the personality inventory for DSM-5 in an APA DSM-5 field trial sample.

    PubMed

    Quilty, Lena C; Ayearst, Lindsay; Chmielewski, Michael; Pollock, Bruce G; Bagby, R Michael

    2013-06-01

    Section 3 of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) includes a hybrid model of personality pathology, in which dimensional personality traits are used to derive one of seven categorical personality disorder diagnoses. The Personality Inventory for DSM-5 (PID-5) was developed by the DSM-5 Personality and Personality Disorders workgroup and their consultants to produce a freely available instrument to assess the personality traits within this new system. To date, the psychometric properties of the PID-5 have been evaluated primarily in undergraduate student and community adult samples. In the current investigation, we extend this line of research to a psychiatric patient sample who participated in the APA DSM-5 Field Trial (Centre for Addiction and Mental Health site). A total of 201 psychiatric patients (102 men, 99 women) completed the PID-5 and the Revised NEO Personality Inventory (NEO PI-R). The internal consistencies of the PID-5 domain and facet trait scales were acceptable. Results supported the unidimensional structure of all trait scales but one, and the convergence between the PID-5 and analogous NEO PI-R scales. Evidence for discriminant validity was mixed. Overall, the current investigation provides support for the psychometric properties of this diagnostic instrument in psychiatric samples.

  8. Bifurcation and chaos of a new discrete fractional-order logistic map

    NASA Astrophysics Data System (ADS)

    Ji, YuanDong; Lai, Li; Zhong, SuChuan; Zhang, Lu

    2018-04-01

    The fractional-order discrete maps with chaotic behaviors based on the theory of ;fractional difference; are proposed in recent years. In this paper, instead of using fractional difference, a new fractionalized logistic map is proposed based on the numerical algorithm of fractional differentiation definition. The bifurcation diagrams of this map with various differential orders are given by numerical simulation. The simulation results show that the fractional-order logistic map derived in this manner holds rich dynamical behaviors because of its memory effect. In addition, new types of behaviors of bifurcation and chaos are found, which are different from those of the integer-order and the previous fractional-order logistic maps.

  9. Fractal electrodynamics via non-integer dimensional space approach

    NASA Astrophysics Data System (ADS)

    Tarasov, Vasily E.

    2015-09-01

    Using the recently suggested vector calculus for non-integer dimensional space, we consider electrodynamics problems in isotropic case. This calculus allows us to describe fractal media in the framework of continuum models with non-integer dimensional space. We consider electric and magnetic fields of fractal media with charges and currents in the framework of continuum models with non-integer dimensional spaces. An application of the fractal Gauss's law, the fractal Ampere's circuital law, the fractal Poisson equation for electric potential, and equation for fractal stream of charges are suggested. Lorentz invariance and speed of light in fractal electrodynamics are discussed. An expression for effective refractive index of non-integer dimensional space is suggested.

  10. [Effects of arnebia root oil on wound healing of rats with full-thickness skin defect and the related mechanism].

    PubMed

    Shen, J Y; Ma, Q; Yang, Z B; Gong, J J; Wu, Y S

    2017-09-20

    Objective: To observe the effects of arnebia root oil on wound healing of rats with full-thickness skin defect, and to explore the related mechanism. Methods: Eighty SD rats were divided into arnebia root oil group and control group according to the random number table, with 40 rats in each group, then full-thickness skin wounds with area of 3 cm×3 cm were inflicted on the back of each rat. Wounds of rats in arnebia root oil group and control group were treated with sterile medical gauze and bandage package infiltrated with arnebia root oil gauze or Vaseline gauze, respectively, with dressing change of once every two days. On post injury day (PID) 3, 7, 14, and 21, 10 rats in each group were sacrificed respectively for general observation and calculation of wound healing rate. The tissue samples of unhealed wound were collected for observation of histomorphological change with HE staining, observation of expressions of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF) with immunohistochemical staining, and determination of mRNA expressions of VEGF and bFGF with real time fluorescent quantitive reverse transcription polymerase chain reaction. Data were processed with analysis of variance of factorial design, t test, and Bonferroni correction. Results: (1) On PID 3, there were a few secretions in wounds of rats in the two groups. On PID 7, there were fewer secretions and more granulation tissue in wounds of rats in arnebia root oil group, while there were more secretions and less granulation tissue in wounds of rats in control group. On PID 14, most of the wounds of rats in arnebia root oil group were healed and there was much red granulation tissue in unhealed wounds, while part of wounds of rats in control group was healed and there were a few secretions and less granulation tissue in unhealed wounds. On PID 21, wounds of rats in arnebia root oil group were basically healed, while there were still some unhealed wounds of rats in control group. (2) On PID 3 and 7, the wound healing rates of rats in arnebia root oil group were (39±5)% and (46±4)% respectively, which were close to (34±3)% and (44±4)% of rats in control group (with t values respectively 0.807 and 0.481, P values above 0.05). On PID 14 and 21, the wound healing rates of rats in arnebia root oil group were (76±4)% and (90±3)% respectively, which were significantly higher than (60±6)% and (73±5)% of rats in control group (with t values respectively 2.308 and 3.072, P <0.05 or P <0.01). (3) On PID 3, 7, and 14, granulation tissue, fibroblasts, and nascent capillaries in unhealed wound tissue of rats in the two groups both gradually increased, and more ranulation tissue, fibroblasts, and nascent capillaries were seen in unhealed wound tissue of rats in arnebia root oil group. On PID 21, granulation tissue, fibroblasts, and nascent capillaries in unhealed wound tissue of rats in the two groups both gradually decreased. (4) On PID 3, 7, and 14, the numbers of VEGF positive cells and bFGF positive cells in unhealed wound tissue of rats in the two groups both gradually increased; there were more VEGF positive cells and bFGF positive cells in unhealed wound tissue of rats in arnebia root oil group than those in control group. On PID 21, positive expressions of VEGF and bFGF both decreased in unhealed wound tissue of rats in the two groups. (5) On PID 3, 7, and 14, mRNA expressions of VEGF in unhealed wound tissue of rats in arnebia root oil group were higher than those of control group (with t values from 2.967 to 4.173, P values below 0.01). On PID 21, mRNA expression of VEGF in unhealed wound tissue of rats in arnebia root oil group was lower than that of control group ( t =-4.786, P <0.001). From PID 3 to 21, mRNA expressions of bFGF in unhealed wound tissue of rats in arnebia root oil group were higher than those of control group (with t values from 2.326 to 4.702, P <0.05 or P <0.01). Conclusions: Arnebia root oil can promote wound healing of rats with full-thickness skin defect, which may relate to increasing expressions of VEGF and bFGF.

  11. Web Services and Handle Infrastructure - WDCC's Contributions to International Projects

    NASA Astrophysics Data System (ADS)

    Föll, G.; Weigelt, T.; Kindermann, S.; Lautenschlager, M.; Toussaint, F.

    2012-04-01

    Climate science demands on data management are growing rapidly as climate models grow in the precision with which they depict spatial structures and in the completeness with which they describe a vast range of physical processes. The ExArch project is exploring the challenges of developing a software management infrastructure which will scale to the multi-exabyte archives of climate data which are likely to be crucial to major policy decisions in by the end of the decade. The ExArch approach to future integration of exascale climate archives is based on one hand on a distributed web service architecture providing data analysis and quality control functionality across archvies. On the other hand a consistent persistent identifier infrastructure is deployed to support distributed data management and data replication. Distributed data analysis functionality is based on the CDO climate data operators' package. The CDO-Tool is used for processing of the archived data and metadata. CDO is a collection of command line Operators to manipulate and analyse Climate and forecast model Data. A range of formats is supported and over 500 operators are provided. CDO presently is designed to work in a scripting environment with local files. ExArch will extend the tool to support efficient usage in an exascale archive with distributed data and computational resources by providing flexible scheduling capabilities. Quality control will become increasingly important in an exascale computing context. Researchers will be dealing with millions of data files from multiple sources and will need to know whether the files satisfy a range of basic quality criterea. Hence ExArch will provide a flexible and extensible quality control system. The data will be held at more than 30 computing centres and data archives around the world, but for users it will appear as a single archive due to a standardized ExArch Web Processing Service. Data infrastructures such as the one built by ExArch can greatly benefit from assigning persistent identifiers (PIDs) to the main entities, such as data and metadata records. A PID should then not only consist of a globally unique identifier, but also support built-in facilities to relate PIDs to each other, to build multi-hierarchical virtual collections and to enable attaching basic metadata directly to PIDs. With such a toolset, PIDs can support crucial data management tasks. For example, data replication performed in ExArch can be supported through PIDs as they can help to establish durable links between identical copies. By linking derivative data objects together, their provenance can be traced with a level of detail and reliability currently unavailable in the Earth system modelling domain. Regarding data transfers, virtual collections of PIDs may be used to package data prior to transmission. If the PID of such a collection is used as the primary key in data transfers, safety of transfer and traceability of data objects across repositories increases. End-users can benefit from PIDs as well since they make data discovery independent from particular storage sites and enable user-friendly communication about primary research objects. A generic PID system can in fact be a fundamental building block for scientific e-infrastructures across projects and domains.

  12. PIDs for digital content: Are they used as they should be? The example of DOI and ORCID, told from a research library perspective

    NASA Astrophysics Data System (ADS)

    Kraft, Angelina; Dreyer, Britta; Löwe, Peter

    2017-04-01

    For finding, linking and citing research content, persistent digital identifiers are the key, as a persistent identifier is a long-lasting reference to a resource. But are PIDs really used as they should be? With respect to the obstacles of the PID systems, we face a diverse landscape of stakeholders, legacy systems, competing interests and often incomprehensible messaging filled with technical jargon around PIDs. Insufficient metadata quality is another major challenge for these systems. While the principal task for service providers lies in collaborating to provide a shared and easy to use PID infrastructure, it is the key responsibility for data centers to provide rich metadata and structured access to research content. Especially metadata and structured access are imperative for the most basic services such as search, citation tracking and reuse. And of course all needs to be human- and machine interoperable, as we want our machines to be able to interpret PIDs depended on a specific use case. Since 2004, the German National Library of Science and Technology (TIB) has been providing DOI services to data centers in Germany. Recent developments make clear that requirements for PIDs have changed. Science has developed a need for PIDs at multiple content levels: In addition to DOIs for journal articles and research data, PIDs for people, physical objects, collections, software, funders, organizations, expeditions, resources, instruments and even for data management plans are required to enable different platforms to exchange information consistently and unambiguously. In this work we want to emphasize on the distinct increases of total DOI registrations for research data and other research output such as images, videos or software in Germany within the past decade and how research institutes and universities differ in their DOI registration workflows. We present use cases which illustrate the deployment of DOIs e.g. for dynamic data, and demonstrate the need of rich metadata for a successful performance of user services. Along with a broader acceptance of DOIs for research content beyond articles, institutes are faced with the challenge of providing appropriate recognition to their researchers for their published work. To promote this, the ORCID Germany Consortium was launched in October 2016. The consortium, administrated by TIB, is an essential building block of the ORCID DE project with the goal to facilitate the distribution of researcher IDs in Germany. An ORCID (Open Researcher and Contributor ID) provides scientists with an unambiguous identifier, enabling them to distinguish themselves from others, while at the same time simplifying the management of their research activity records (e.g. publications of papers, dissertation, research data, software, and attended conferences). ORCID Germany Consortium member institutions are able to link their academic records to the ORCID identifiers of their researchers and benefit from up-to-date and complete publication lists. DOIs and ORCIDs, if used correctly, are both machine-interoperable PIDs which not only make research more accessible, but also increase the visibility of all outputs of research, the researcher and the affiliated institution.

  13. System using leo satellites for centimeter-level navigation

    NASA Technical Reports Server (NTRS)

    Rabinowitz, Matthew (Inventor); Parkinson, Bradford W. (Inventor); Cohen, Clark E. (Inventor); Lawrence, David G. (Inventor)

    2002-01-01

    Disclosed herein is a system for rapidly resolving position with centimeter-level accuracy for a mobile or stationary receiver [4]. This is achieved by estimating a set of parameters that are related to the integer cycle ambiguities which arise in tracking the carrier phase of satellite downlinks [5,6]. In the preferred embodiment, the technique involves a navigation receiver [4] simultaneously tracking transmissions [6] from Low Earth Orbit Satellites (LEOS) [2] together with transmissions [5] from GPS navigation satellites [1]. The rapid change in the line-of-sight vectors from the receiver [4] to the LEO signal sources [2], due to the orbital motion of the LEOS, enables the resolution with integrity of the integer cycle ambiguities of the GPS signals [5] as well as parameters related to the integer cycle ambiguity on the LEOS signals [6]. These parameters, once identified, enable real-time centimeter-level positioning of the receiver [4]. In order to achieve high-precision position estimates without the use of specialized electronics such as atomic clocks, the technique accounts for instabilities in the crystal oscillators driving the satellite transmitters, as well as those in the reference [3] and user [4] receivers. In addition, the algorithm accommodates as well as to LEOS that receive signals from ground-based transmitters, then re-transmit frequency-converted signals to the ground.

  14. Indirect detection of 10B (I = 3) overtone NMR at very fast magic angle spinning

    NASA Astrophysics Data System (ADS)

    Duong, Nghia Tuan; Kuprov, Ilya; Nishiyama, Yusuke

    2018-06-01

    The application of overtone nuclear magnetic resonance (OT NMR) to symmetric spin transitions of integer quadrupolar nuclei is of considerable interest since this transition is immune to the first-order quadrupolar interaction, thus resulting in narrow NMR lines. Owing to its roles in nature and its high natural abundance, 14N (I = 1) OT NMR has been explored, in which the indirect and/or direct acquisitions of 14N OT were experimentally demonstrated. However, other than 14N nucleus, no OT NMR observation of other integer quadrupolar nuclei has been reported in the literature. In this work, we extend the application of OT NMR to another integer quadrupolar nucleus, namely 10B (I = 3). However, this is not straightforward owing to the unfavorable characteristics of 10B isotope. Here, for the first time, we present the selective acquisition of 10B central (-1 ↔ +1) OT NMR via detection of 1H nuclei on perborate monohydrate sample. Numerical calculations are in a good agreement with the experimental results. Both show that the optimal sensitivity is achieved when the carrier frequency is applied at the second OT spinning sideband, i.e. an offset of twice of the spinning frequency from the center band.

  15. Generating subtour elimination constraints for the TSP from pure integer solutions.

    PubMed

    Pferschy, Ulrich; Staněk, Rostislav

    2017-01-01

    The traveling salesman problem ( TSP ) is one of the most prominent combinatorial optimization problems. Given a complete graph [Formula: see text] and non-negative distances d for every edge, the TSP asks for a shortest tour through all vertices with respect to the distances d. The method of choice for solving the TSP to optimality is a branch and cut approach . Usually the integrality constraints are relaxed first and all separation processes to identify violated inequalities are done on fractional solutions . In our approach we try to exploit the impressive performance of current ILP-solvers and work only with integer solutions without ever interfering with fractional solutions. We stick to a very simple ILP-model and relax the subtour elimination constraints only. The resulting problem is solved to integer optimality, violated constraints (which are trivial to find) are added and the process is repeated until a feasible solution is found. In order to speed up the algorithm we pursue several attempts to find as many relevant subtours as possible. These attempts are based on the clustering of vertices with additional insights gained from empirical observations and random graph theory. Computational results are performed on test instances taken from the TSPLIB95 and on random Euclidean graphs .

  16. Finding One's Meaning: A Test of the Relation between Quantifiers and Integers in Language Development

    ERIC Educational Resources Information Center

    Barner, David; Chow, Katherine; Yang, Shu-Ju

    2009-01-01

    We explored children's early interpretation of numerals and linguistic number marking, in order to test the hypothesis (e.g., Carey (2004). Bootstrapping and the origin of concepts. "Daedalus", 59-68) that children's initial distinction between "one" and other numerals (i.e., "two," "three," etc.) is bootstrapped from a prior distinction between…

  17. Integrating Test-Form Formatting into Automated Test Assembly

    ERIC Educational Resources Information Center

    Diao, Qi; van der Linden, Wim J.

    2013-01-01

    Automated test assembly uses the methodology of mixed integer programming to select an optimal set of items from an item bank. Automated test-form generation uses the same methodology to optimally order the items and format the test form. From an optimization point of view, production of fully formatted test forms directly from the item pool using…

  18. [Validation of a French translation of Krueger's personality inventory for DSM-5 in its brief form (PID-5 BF)].

    PubMed

    Combaluzier, S; Gouvernet, B; Menant, F; Rezrazi, A

    2018-02-01

    Since the publication of the DSM-5 (APA, 2013), the dimensional conception of the personality disorders is co-existing with the classical categorical paradigm. Tools have been proposed for the evaluations of five big pathological factors to be explored further according to the APA (negative affectivity, detachment, antagonism, disinhibition, psychoticism). Despite numerous works using these questionnaires (30 works in 3 years according to Al-Adjani et al., 2015), none of them have yet been translated into French. Also, the main objective of the paper is to present a French translation of the Personality Inventory for DSM -5 by Kruegger et al. (2013) in its brief form of 25 items (PID-5 BF). To reach this goal, we have employed the classic translation-retranslation method (Vallerand, 1989) and tested the consistence and the validity of this French version among a non-clinical sample (n=216) of young adults (age=31.4, SD=4.8), in joining some other questionnaires in their short forms to study the external validity of the PID-5 about the psychological distress (SCL-10, Nguyen, 1983), the categorical diagnosis of personality disorders (SAPAS, Moran et al., 2003) and the classical Big Five dimensions of the personality (BDI 10, Ramamstedt and John, 2007). The internal consistency of this translation has been studied through the classical outcomes on factor analysis for the dimensional repartitions of the items in 5 scales and Cronbach's alpha for the consistency of each found dimensions. The external validity has been explored by studying Pearson's correlations between the outcomes on each dimension of the PID-5 BF and both the clinical dimensions of SCL-10, personality dimensions of the BFI-10 or personality disorders (SAPAS). Factor analysis led to the same repartition of the 25 items as the original versions. Each of the dimensions is consistent enough (α>.65) to be taken into account as clinically significant. The items of the French version of the PID-5 BF follow the expected repartitions in 5 dimensions, which are consistent enough. Although their mean scores are significantly not different from the outcomes found by Krueger with the PID-5 200 items among another non-clinical population (n=264), one cannot say that is enough to ensure the external validity of our translation, for it uses neither the same tools nor sample. A comparison with a French translation of the PID-5 would be more significant. However, the external validity of the French version seems to be significant enough. Global score on the PID-5 is correlated both to the Global Severity Index of the SCL-10, which reflects global psychological distress, and SAPAS's score, which evaluates the suspicion of personality disorder. The clinical validity of the PID-5 is confirmed by the relationships between negative affectivity and anxiety or depression or antagonism and hostility, although the clinical scale of the SCL-10, with one item by dimension, is less sensitive than the complete original version in 90 items (DeRogatis, 1974). PID-5 score and domains are also correlated with the Big Five personality dimension and global score of personality disorders which led us to think that it is coherent with the evaluation of personality suffering (r=.34) and dimensions. The links between negative affectivity and neurosism (r=.48) or between desinhibition and extraversion (r=.32) or the negative correlation between psychoticism and conscientiousness (r=-0.16) are consistent with the expectations related both to the descriptions of the domains by the DSM and outcomes on the comparisons between PID-5 200 item scales and NEO-PI or BFI 45 items. This translation offers enough consistency and validity to be used in future studies. This could lead us to either continue studying a more representative general population or testing its validity in focusing on a clinical sample where personality disorders are prevalent, such as homeless men or substance users. As soon as a French version of the PID-5 200 items is published, one can compare the outcomes on PID-5 BF and PID-5 to lead to estimations of personality disorders and pathological domains among French populations and explore personality disorders throughout a dimensional paradigm instead of syndromic perspective. One can also see whether the items that have been kept for each dimension are as saturated in the French version as in the original one. Among general populations, comparisons with clinical distress, syndromic personality disorders or dimensional aspect of personality could be done with complete versions of PID-5, Symptom Check-list, Personality Disorders Questionnaires or Big Five Inventory; therefore, the brief forms of any questionnaire could be used among any people whose psychological distress or side effects impaired their attention and concentration. Copyright © 2016 L'Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.

  19. Use of the fractional Fourier transform in {pi}/2 converters of laser modes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malyutin, A A

    2004-02-28

    The possibility of using the fractional Fourier transform (FrFT) in optical schemes for astigmatic {pi}/2 converters of Hermite-Gaussian modes to donut Laguerre-Gaussian modes is considered. Several schemes of converters based on the FrFT of the half-integer and irrational orders are presented. The lowest FrFT order than can be used in astigmatic mode converters is found. The properties of converters based on the fractional and ordinary Fourier transforms are compared. (laser beams)

  20. Computer program for Bessel and Hankel functions

    NASA Technical Reports Server (NTRS)

    Kreider, Kevin L.; Saule, Arthur V.; Rice, Edward J.; Clark, Bruce J.

    1991-01-01

    A set of FORTRAN subroutines for calculating Bessel and Hankel functions is presented. The routines calculate Bessel and Hankel functions of the first and second kinds, as well as their derivatives, for wide ranges of integer order and real or complex argument in single or double precision. Depending on the order and argument, one of three evaluation methods is used: the power series definition, an Airy function expansion, or an asymptotic expansion. Routines to calculate Airy functions and their derivatives are also included.

  1. Deriving ICD-11 personality disorder domains from dsm-5 traits: initial attempt to harmonize two diagnostic systems.

    PubMed

    Bach, B; Sellbom, M; Kongerslev, M; Simonsen, E; Krueger, R F; Mulder, R

    2017-07-01

    The personality disorder domains proposed for the ICD-11 comprise Negative Affectivity, Detachment, Dissociality, Disinhibition, and Anankastia, which are reasonably concordant with the higher-order trait domains in the Alternative DSM-5 Model for Personality Disorders. We examined (i) whether designated DSM-5 trait facets can be used to describe the proposed ICD-11 trait domains, and (ii) how these ICD-11 trait features are hierarchically organized. A mixed Danish derivation sample (N = 1541) of 615 psychiatric out-patients and 925 community participants along with a US replication sample (N = 637) completed the Personality Inventory for DSM-5 (PID-5). Sixteen PID-5 traits were designated to cover features of the ICD-11 trait domains. Exploratory structural equation modeling (ESEM) analyzes showed that the designated traits were meaningfully organized in the proposed ICD-11 five-domain structure as well as other recognizable higher-order models of personality and psychopathology. Model fits revealed that the five proposed ICD-11 personality disorder domains were satisfactorily resembled, and replicated in the independent US sample. The proposed ICD-11 personality disorder domains can be accurately described using designated traits from the DSM-5 personality trait system. A scoring algorithm for the ICD-11 personality disorder domains is provided in appendix. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. System-wide hybrid MPC-PID control of a continuous pharmaceutical tablet manufacturing process via direct compaction.

    PubMed

    Singh, Ravendra; Ierapetritou, Marianthi; Ramachandran, Rohit

    2013-11-01

    The next generation of QbD based pharmaceutical products will be manufactured through continuous processing. This will allow the integration of online/inline monitoring tools, coupled with an efficient advanced model-based feedback control systems, to achieve precise control of process variables, so that the predefined product quality can be achieved consistently. The direct compaction process considered in this study is highly interactive and involves time delays for a number of process variables due to sensor placements, process equipment dimensions, and the flow characteristics of the solid material. A simple feedback regulatory control system (e.g., PI(D)) by itself may not be sufficient to achieve the tight process control that is mandated by regulatory authorities. The process presented herein comprises of coupled dynamics involving slow and fast responses, indicating the requirement of a hybrid control scheme such as a combined MPC-PID control scheme. In this manuscript, an efficient system-wide hybrid control strategy for an integrated continuous pharmaceutical tablet manufacturing process via direct compaction has been designed. The designed control system is a hybrid scheme of MPC-PID control. An effective controller parameter tuning strategy involving an ITAE method coupled with an optimization strategy has been used for tuning of both MPC and PID parameters. The designed hybrid control system has been implemented in a first-principles model-based flowsheet that was simulated in gPROMS (Process System Enterprise). Results demonstrate enhanced performance of critical quality attributes (CQAs) under the hybrid control scheme compared to only PID or MPC control schemes, illustrating the potential of a hybrid control scheme in improving pharmaceutical manufacturing operations. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Adoptive immunotherapy for primary immunodeficiency disorders with virus-specific T lymphocytes.

    PubMed

    Naik, Swati; Nicholas, Sarah K; Martinez, Caridad A; Leen, Ann M; Hanley, Patrick J; Gottschalk, Steven M; Rooney, Cliona M; Hanson, I Celine; Krance, Robert A; Shpall, Elizabeth J; Cruz, Conrad R; Amrolia, Persis; Lucchini, Giovanna; Bunin, Nancy; Heimall, Jennifer; Klein, Orly R; Gennery, Andrew R; Slatter, Mary A; Vickers, Mark A; Orange, Jordan S; Heslop, Helen E; Bollard, Catherine M; Keller, Michael D

    2016-05-01

    Viral infections are a leading fatal complication for patients with primary immunodeficiencies (PIDs) who require hematopoietic stem cell transplantation (HSCT). Use of virus-specific T lymphocytes (VSTs) has been successful for the treatment and prevention of viral infections after HSCT for malignant and nonmalignant conditions. Here we describe the clinical use of VSTs in patients with PIDs at 4 centers. We sought to evaluate the safety and efficacy of VSTs for treatment of viral infections in patients with PIDs. Patients with PIDs who have received VST therapy on previous or current protocols were reviewed in aggregate. Clinical information, including transplantation details, viral infections, and use of antiviral and immunosuppressive pharmacotherapy, were evaluated. Data regarding VST production, infusions, and adverse reactions were compared. Thirty-six patients with 12 classes of PID diagnoses received 37 VST products before or after HSCT. Twenty-six (72%) patients had received a diagnosis of infection with cytomegalovirus, EBV, adenovirus, BK virus, and/or human herpesvirus 6. Two patients were treated before HSCT because of EBV-associated lymphoproliferative disease. Partial or complete responses against targeted viruses occurred in 81% of patients overall. Time to response varied from 2 weeks to 3 months (median, 28 days). Overall survival at 6 months after therapy was 80%. Four patients had graft-versus-host disease in the 45 days after VST infusion, which in most cases was therapy responsive. VSTs derived from either stem cell donors or third-party donors are likely safe and effective for the treatment of viral infections in patients with PIDs. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. Use of transabdominal ultrasound-guided amniocentesis for detection of equid herpesvirus 1-induced fetal infection in utero.

    PubMed

    Smith, K C; McGladdery, A J; Binns, M M; Mumford, J A

    1997-09-01

    To evaluate transabdominal ultrasound-guided amniocentesis for detection of equid herpes-virus 1 (EHV-1)-induced fetal infection in utero. 4 Welsh Mountain mares. Pregnant mares were inoculated intranasally with EHV-1 during the ninth month of gestation. Amniocentesis was initiated on postinoculation day (PID) 12, and was performed at 2- to 3-day intervals in standing mares under deep sedation. Amniotic fluid samples were tested by virus isolation (VI), polymerase chain reaction (PCR), and immunoperoxidase cytologic examination (IC) for detection of EHV-1. Exposure to EHV-1 in the ninth month of gestation resulted in nasal shedding of infective virus, establishment of cell-associated viremia, and seroconversion. Equid herpesvirus 1 was detected by VI, PCR, and IC in amniotic fluid collected on PID 14 from 1 mare and on PID 16 and 17 from a second mare. Specimens of amniotic fluid from a third mare were VI negative until PID 18, when collections ceased, although this mare subsequently aborted an EHV-1-infected fetus on PID 28. The fourth mare aborted an EHV-1 infected fetus on PID 14. The 2 mares with VI-positive amniotic fluid were each carrying an EHV-1 infected fetus in utero, confirmed by examination of the uterus, placenta, and fetus, using specific immunohistochemistry and in situ hybridization. Endothelial cells in the endometrium and allantochorion were often virus-infected, with accompanying vascular lesions. The fetus had been infected via the chorionic vasculature in the first and fourth mares, and by inhalation of infected amniotic fluid in the second mare. Amniocentesis permits specific detection of EHV-1-induced fetal infection in utero. Amniocentesis may have a clinical role in the specific identification and isolation of mares carrying virus-infected fetuses during EHV-1-induced abortion epizootics.

  5. Myocarditis in mice and guinea pigs experimentally infected with a canine-origin Borrelia isolate from Florida.

    PubMed

    Breitschwerdt, E B; Geoly, F J; Meuten, D J; Levine, J F; Howard, P; Hegarty, B C; Stafford, L C

    1996-04-01

    To characterize the pathogenic potential of a unique Borrelia isolate obtained from a dog from Florida (FCB isolate). Prospective experimental infection. 32 preweanling Swiss Webster mice and 12 adult male Hartley guinea pigs were injected intraperitoneally with 10(5) spirochetes. Mice were used as controls and blood recipients, and at 3- to 4-day intervals, 1 control mouse and 2 infected mice were necropsied, tissues were cultured, and a recipient mouse was inoculated with blood. Guinea pigs were randomized to 4 groups and inoculated intradermally with 10(0), 10(2), 10(3), or 10(4) spirochetes. For 48 days, clinical, hematologic, serologic, and microbiologic tests were performed on them, after which they were necropsied. In mice, spirochetemia was detectable between postinoculation days (PID) 3 and 13, and seroreactivity to homologous antigen was detectable during PID 10 through 31. Compared with control mice, infected mouse spleens were 2 to 3 times larger. Histologic lesions included lymphoid hyperplasia, neutrophilic panniculitis, epicarditis, and myocarditis, with intralesional spirochetes detected from PID 3 through 6. During PID 10 through 31, nonsuppurative epicarditis developed. Signs of illness and hematologic abnormalities were not observed in guinea pigs, despite isolating spirochetes from blood during PID 7 to 27. When necropsied on PID 48, histologic lesions included lymphoid hyperplasia and lymphocytic plasmacytic epicarditis. The FCB isolate causes spirochetemia, lymphoid hyperplasia, dermatitis, and myocardial injury in Swiss Webster mice and can be transmitted by blood inoculation. In Hartley guinea pigs, the isolate causes spirochetemia, lymphoid hyperplasia, and epicarditis. Documentation of disease in mice, guinea pigs, and, presumably, dogs raises the level of concern that the FCB isolate might be pathogenic for man and other animal species.

  6. Diagnosis of primary antibody and complement deficiencies in young adults after a first invasive bacterial infection.

    PubMed

    Sanges, S; Wallet, F; Blondiaux, N; Theis, D; Vérin, I; Vachée, A; Dessein, R; Faure, K; Viget, N; Senneville, E; Leroy, O; Maury, F; Just, N; Poissy, J; Mathieu, D; Prévotat, A; Chenivesse, C; Scherpereel, A; Smith, G; Lopez, B; Rosain, J; Frémeaux-Bacchi, V; Hachulla, E; Hatron, P-Y; Bahuaud, M; Batteux, F; Launay, D; Labalette, M; Lefèvre, G

    2017-08-01

    Screening for primary immunodeficiencies (PIDs) in adults is recommended after two severe bacterial infections. We aimed to evaluate if screening should be performed after the first invasive infection in young adults. Eligible patients were retrospectively identified using hospital discharge and bacteriology databases in three centres during a 3-year period. Eighteen to 40-year-old patients were included if they had experienced an invasive infection with encapsulated bacteria commonly encountered in PIDs (Streptococcus pneumoniae (SP), Neisseria meningitidis (NM), Neisseria gonorrhoeae (NG), Haemophilus influenzae (HI), or group A Streptococcus (GAS)). They were excluded in case of general or local predisposing factors. Immunological explorations and PIDs diagnoses were retrieved from medical records. Serum complement and IgG/A/M testings were systematically proposed at the time of study to patients with previously incomplete PID screening. The study population comprised 38 patients. Thirty-six had experienced a first invasive episode and a PID was diagnosed in seven (19%): two cases of common variable immunodeficiency revealed by SP bacteraemia, one case of idiopathic primary hypogammaglobulinaemia, and two cases of complement (C6 and C7) deficiency revealed by NM meningitis, one case of IgG2/IgG4 subclasses deficiency revealed by GAS bacteraemia, and one case of specific polysaccharide antibody deficiency revealed by HI meningitis. Two patients had previously experienced an invasive infection before the study period: in both cases, a complement deficiency was diagnosed after a second NM meningitis and a second NG bacteraemia, respectively. PID screening should be considered after a first unexplained invasive encapsulated-bacterial infection in young adults. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  7. Professional driving and prolapsed lumbar intervertebral disc diagnosed by magnetic resonance imaging – a case–control study

    PubMed Central

    Palmer, Keith T; Griffin, Michael; Ntani, Georgia; Shambrook, James; McNee, Philip; Sampson, Madeleine; Harris, E Clare; Coggon, David

    2012-01-01

    Objectives The aim of this study was to investigate whether whole-body vibration (WBV) is associated with prolapsed lumbar intervertebral disc (PID) and nerve root entrapment among patients with low-back pain (LBP) undergoing magnetic resonance imaging (MRI). Methods A consecutive series of patients referred for lumbar MRI because of LBP were compared with controls X-rayed for other reasons. Subjects were questioned about occupational activities loading the spine, psychosocial factors, driving, personal characteristics, mental health, and certain beliefs about LBP. Exposure to WBV was assessed by six measures, including weekly duration of professional driving, hours driven at a spell, and current 8-hour daily equivalent root-mean-square acceleration A(8). Cases were sub-classified according to whether or not PID/nerve root entrapment was present. Associations with WBV were examined separately for cases with and without these MRI findings, with adjustment for age, sex, and other potential confounders. Results Altogether, 237 cases and 820 controls were studied, including 183 professional drivers and 176 cases with PID and/or nerve root entrapment. Risks associated with WBV tended to be lower for LBP with PID/nerve root entrapment but somewhat higher for risks of LBP without these abnormalities. However, associations with the six metrics of exposure were all weak and not statistically significant. Neither exposure–response relationships nor increased risk of PID/nerve root entrapment from professional driving or exposure at an A(8) above the European Union daily exposure action level were found. Conclusions WBV may be a cause of LBP but it was not associated with PID or nerve root entrapment in this study. PMID:22249859

  8. Erythropoietin Improved Cognitive Function and Decreased Hippocampal Caspase Activity in Rat Pups after Traumatic Brain Injury

    PubMed Central

    Requena, Daniela F.; Block, Benjamin; Davis, Lizeth J.; Rodesch, Christopher; Casper, T. Charles; Juul, Sandra E.; Kesner, Raymond P.; Lane, Robert H.

    2014-01-01

    Abstract Traumatic brain injury (TBI) is a leading cause of acquired neurologic disability in children. Erythropoietin (EPO), an anti-apoptotic cytokine, improved cognitive outcome in adult rats after TBI. To our knowledge, EPO has not been studied in a developmental TBI model. Hypothesis: We hypothesized that EPO would improve cognitive outcome and increase neuron fraction in the hippocampus in 17-day-old (P17) rat pups after controlled cortical impact (CCI). Methods: EPO or vehicle was given at 1, 24, and 48 h after CCI and at post injury day (PID) 7. Cognitive outcome at PID14 was assessed using Novel Object Recognition (NOR). Hippocampal EPO levels, caspase activity, and mRNA levels of the apoptosis factors Bcl2, Bax, Bcl-xL, and Bad were measured during the first 14 days after injury. Neuron fraction and caspase activation in CA1, CA3, and DG were studied at PID2. Results: EPO normalized recognition memory after CCI. EPO blunted the increased hippocampal caspase activity induced by CCI at PID1, but not at PID2. EPO increased neuron fraction in CA3 at PID2. Brain levels of exogenous EPO appeared low relative to endogenous. Timing of EPO administration was associated with temporal changes in hippocampal mRNA levels of EPO and pro-apoptotic factors. Conclusion/Speculation: EPO improved recognition memory, increased regional hippocampal neuron fraction, and decreased caspase activity in P17 rats after CCI. We speculate that EPO improved cognitive outcome in rat pups after CCI as a result of improved neuronal survival via inhibition of caspase-dependent apoptosis early after injury. PMID:23972011

  9. A design of LED adaptive dimming lighting system based on incremental PID controller

    NASA Astrophysics Data System (ADS)

    He, Xiangyan; Xiao, Zexin; He, Shaojia

    2010-11-01

    As a new generation energy-saving lighting source, LED is applied widely in various technology and industry fields. The requirement of its adaptive lighting technology is more and more rigorous, especially in the automatic on-line detecting system. In this paper, a closed loop feedback LED adaptive dimming lighting system based on incremental PID controller is designed, which consists of MEGA16 chip as a Micro-controller Unit (MCU), the ambient light sensor BH1750 chip with Inter-Integrated Circuit (I2C), and constant-current driving circuit. A given value of light intensity required for the on-line detecting environment need to be saved to the register of MCU. The optical intensity, detected by BH1750 chip in real time, is converted to digital signal by AD converter of the BH1750 chip, and then transmitted to MEGA16 chip through I2C serial bus. Since the variation law of light intensity in the on-line detecting environment is usually not easy to be established, incremental Proportional-Integral-Differential (PID) algorithm is applied in this system. Control variable obtained by the incremental PID determines duty cycle of Pulse-Width Modulation (PWM). Consequently, LED's forward current is adjusted by PWM, and the luminous intensity of the detection environment is stabilized by self-adaptation. The coefficients of incremental PID are obtained respectively after experiments. Compared with the traditional LED dimming system, it has advantages of anti-interference, simple construction, fast response, and high stability by the use of incremental PID algorithm and BH1750 chip with I2C serial bus. Therefore, it is suitable for the adaptive on-line detecting applications.

  10. Stress exposure and the risk for the onset of alcohol use disorders and nicotine dependence in deployed military personnel: the role of prior internalizing disorders.

    PubMed

    Trautmann, Sebastian; Schönfeld, Sabine; Behrendt, Silke; Heinrich, Anke; Höfler, Michael; Siegel, Stefan; Zimmermann, Peter; Wittchen, Hans-Ulrich

    2015-04-01

    This prospective study aimed to investigate whether prior internalizing disorders (PIDs) moderate the relationship between stress exposure (SE) and the onset of alcohol use disorders (AUDs) and nicotine dependence (ND) in deployed military personnel. 358 male soldiers were examined directly before and 12months after return from deployment using standardized interviews. Combat experiences, concerns about family disruptions, and difficult living and working environment were assessed as different aspects of SE. PID diagnoses (mood disorders (PMDs), anxiety disorders (PADs)) and substance use disorders were defined according to the DSM-IV-TR. PMDs were related to a stronger association between concerns about family disruptions and the risk of AUD onset (OR=7.7, 95% CI 1.8-32.8, p=0.006). The number of PID diagnoses (OR per diagnosis: 1.7, 95% CI 1.0-2.8, p=0.036) and PADs (OR: 2.6, 95% CI 1.1-6.3, p=0.038) were further related to a stronger association between difficult living and working environment and the risk of AUD onset. With regard to ND, PMDs were related to a weaker association between difficult living and working environment and the risk of ND onset (OR=0.4, 95% CI 0.2-0.8, p=0.013). PIDs might be related to an increased risk for the onset of AUDs but not ND following SE. This effect is probably restricted to specific constellations of PADs, PMDs, comorbid PIDs and specific aspects of SE. These critical constellations of PIDs and SE might be a promising target for future research and could contribute to the development of preventive measures to reduce the risk of AUDs following SE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. An evaluation of the budget impact of a new 20% subcutaneous immunoglobulin (Ig20Gly) for the management of primary immunodeficiency diseases in Switzerland.

    PubMed

    Pollock, Richard F; Meckley, Lisa M

    2018-01-01

    While most individual primary immunodeficiency diseases (PID) are rare, the collective prevalence of PID results in a substantial economic and clinical burden. The aim of this study was to evaluate the budgetary implications of Ig20Gly (Immune Globulin Subcutaneous [human] 20% solution; CUVITRU ® , Baxalta US Inc, now part of Shire Plc, Westlake Village, CA, USA) as a treatment for PID relative to intravenous immunoglobulin (IVIG) and other subcutaneous immunoglobulin (SCIG) formulations in the Swiss health care setting. A budget impact model was developed in Microsoft Excel to capture the estimated prevalence of PID in Switzerland, the proportion of patients treated in different health care settings, and the costs of administering SCIG and IVIG in each setting. Unit costs were based on a recent cost-minimization analysis of SCIG in Lausanne, and drug costs were taken from the Spezialitätenliste. All costs were reported in 2016 Swiss Francs (CHF), and future costs were not discounted. The total cost of treating PID in Switzerland was estimated to be CHF 11.16 m over 3 years, comprising CHF 9.28 m of drug costs and CHF 1.87 m of ancillary costs, including health care professional time and other administration costs, such as pumps and needle sets. The analysis showed that using Ig20Gly in place of other SCIG formulations would be cost neutral, while using Ig20Gly in place of IVIG would result in savings of 4.0%. Ig20Gly would be cost neutral relative to existing SCIG products and would result in cost savings relative to IVIG in patients with PID in Switzerland, even with modest uptake.

  12. Management of first-episode pelvic inflammatory disease in primary care: results from a large UK primary care database.

    PubMed

    Nicholson, Amanda; Rait, Greta; Murray-Thomas, Tarita; Hughes, Gwenda; Mercer, Catherine H; Cassell, Jackie

    2010-10-01

    Prompt and effective treatment of pelvic inflammatory disease (PID) may help prevent long-term complications. Many PID cases are seen in primary care but it is not known how well management follows recommended guidelines. To estimate the incidence of first-episode PID cases seen in UK general practice, describe their management, and assess its adequacy in relation to existing guidelines. Cohort study. UK general practices contributing to the General Practice Research Database (GPRD). Women aged 15 to 40 years, consulting with a first episode of PID occurring between 30 June 2003 and 30 June 2008 were identified, based on the presence of a diagnostic code. The records within 28 days either side of the diagnosis date were analysed to describe management. A total of 3797 women with a first-ever coded diagnosis of PID were identified. Incidence fell during the study period from 19.3 to 8.9/10 000 person-years. Thirty-four per cent of cases had evidence of care elsewhere, while 2064 (56%) appeared to have been managed wholly within the practice. Of these 2064 women, 34% received recommended treatment including metronidazole, and 54% had had a Chlamydia trachomatis test, but only 16% received both. Management was more likely to follow guidelines in women in their 20s, and later in the study period. These analyses suggest that the management of PID in UK primary care, although improving, does not follow recommended guidelines for the majority of women. Further research is needed to understand the delivery of care in general practice and the coding of such complex syndromic conditions.

  13. Comparative pathology of pigs infected with Korean H1N1, H1N2, or H3N2 swine influenza A viruses.

    PubMed

    Lyoo, Kwang-Soo; Kim, Jeong-Ki; Jung, Kwonil; Kang, Bo-Kyu; Song, Daesub

    2014-09-24

    The predominant subtypes of swine influenza A virus (SIV) in Korea swine population are H1N1, H1N2, and H3N2. The viruses are genetically close to the classical U.S. H1N1 and triple-reassortant H1N2 and H3N2 viruses, respectively. Comparative pathogenesis caused by Korean H1N1, H1N2, and H3N2 SIV was evaluated in this study. The H3N2 infected pigs had severe scores of gross and histopathological lesions at post-inoculation days (PID) 2, and this then progressively decreased. Both the H1N1 and H1N2 infected pigs lacked gross lesions at PID 2, but they showed moderate to severe pneumonia on PID 4, 7 and 14. The pigs infected with H1N1 had significant scores of gross and histopathological lesions when compared with the other pigs infected with H1N2, H3N2, and mock at PID 14. Mean SIV antigen-positive scores were rarely detected for pigs infected with H1N2 and H3N2 from PID 7, whereas a significantly increased amount of viral antigens were found in the bronchioles and alveolar epithelium of the H1N1infected pigs at PID 14. We demonstrated that Korean SIV subtypes had different pulmonary pathologic patterns. The Korean H3N2 rapidly induced acute lung lesions such as broncho-interstitial pneumonia, while the Korean H1N1 showed longer course of infection as compared to other strains.

  14. Cost-effectiveness of microscopy of urethral smears for asymptomatic Mycoplasma genitalium urethritis in men in England.

    PubMed

    Sutton, Andrew J; Roberts, Tracy E; Jackson, Louise; Saunders, John; White, Peter J; Birger, Ruthie; Estcourt, Claudia

    2018-01-01

    The objective was to determine whether or not the limited use of urethral microscopy to diagnose asymptomatic and symptomatic non-chlamydial, non-gonococcal urethritis (NCNGU) in men is a cost-effective strategy to avert pelvic inflammatory disease (PID), ectopic pregnancy or infertility in female partners. Outputs from a transmission dynamic model of NCNGU in a population of 16-30 year olds in England simulating the number of consultations, PID cases and patients treated over time amongst others, were used along with secondary data to undertake a cost-effectiveness analysis carried out from a health care provider perspective. The main outcome measure was cost per case of PID averted. A secondary outcome measure was cost per major outcome averted, where a major outcome is a case of symptomatic PID, ectopic pregnancy, or infertility. Offering a limited number of asymptomatic men urethral microscopy was more effective than the current practice of no microscopy in terms of reducing the number of cases of PID with an incremental cost-effectiveness ratio of £15,700, meaning that an investment of £15,800 is required to avert one case of PID. For major outcomes averted, offering some asymptomatic men urethral microscopy was again found to be more effective than no microscopy, but here an investment of £49,900 is required to avert one major outcome. Testing asymptomatic men for NCNGU in a small number of genitourinary medicine settings in England is not cost-effective, and thus by maintaining the current practice of not offering this patient group microscopy, this continues to make savings for the health care provider.

  15. Adaptive fuzzy logic controller with direct action type structures for InnoSAT attitude control system

    NASA Astrophysics Data System (ADS)

    Bakri, F. A.; Mashor, M. Y.; Sharun, S. M.; Bibi Sarpinah, S. N.; Abu Bakar, Z.

    2016-10-01

    This study proposes an adaptive fuzzy controller for attitude control system (ACS) of Innovative Satellite (InnoSAT) based on direct action type structure. In order to study new methods used in satellite attitude control, this paper presents three structures of controllers: Fuzzy PI, Fuzzy PD and conventional Fuzzy PID. The objective of this work is to compare the time response and tracking performance among the three different structures of controllers. The parameters of controller were tuned on-line by adjustment mechanism, which was an approach similar to a PID error that could minimize errors between actual and model reference output. This paper also presents a Model References Adaptive Control (MRAC) as a control scheme to control time varying systems where the performance specifications were given in terms of the reference model. All the controllers were tested using InnoSAT system under some operating conditions such as disturbance, varying gain, measurement noise and time delay. In conclusion, among all considered DA-type structures, AFPID controller was observed as the best structure since it outperformed other controllers in most conditions.

  16. 10 Aspects of the Big Five in the Personality Inventory for DSM-5

    PubMed Central

    DeYoung, Colin. G.; Carey, Bridget E.; Krueger, Robert F.; Ross, Scott R.

    2015-01-01

    DSM-5 includes a dimensional model of personality pathology, operationalized in the Personality Inventory for DSM-5 (PID-5), with 25 facets grouped into five higher-order factors resembling the Big Five personality dimensions. The present study tested how well these 25 facets could be integrated with the 10-factor structure of traits within the Big Five that is operationalized by the Big Five Aspect Scales (BFAS). In two healthy adult samples, 10-factor solutions largely confirmed our hypothesis that each of the 10 BFAS scales would be the highest loading BFAS scale on one and only one factor. Varying numbers of PID-5 scales were additional markers of each factor, and the overall factor structure in the first sample was well replicated in the second. Our results allow Cybernetic Big Five Theory (CB5T) to be brought to bear on manifestations of personality disorder, because CB5T offers mechanistic explanations of the 10 factors measured by the BFAS. Future research, therefore, may begin to test hypotheses derived from CB5T regarding the mechanisms that are dysfunctional in specific personality disorders. PMID:27032017

  17. The Lateral Tracking Control for the Intelligent Vehicle Based on Adaptive PID Neural Network.

    PubMed

    Han, Gaining; Fu, Weiping; Wang, Wen; Wu, Zongsheng

    2017-05-30

    The intelligent vehicle is a complicated nonlinear system, and the design of a path tracking controller is one of the key technologies in intelligent vehicle research. This paper mainly designs a lateral control dynamic model of the intelligent vehicle, which is used for lateral tracking control. Firstly, the vehicle dynamics model (i.e., transfer function) is established according to the vehicle parameters. Secondly, according to the vehicle steering control system and the CARMA (Controlled Auto-Regression and Moving-Average) model, a second-order control system model is built. Using forgetting factor recursive least square estimation (FFRLS), the system parameters are identified. Finally, a neural network PID (Proportion Integral Derivative) controller is established for lateral path tracking control based on the vehicle model and the steering system model. Experimental simulation results show that the proposed model and algorithm have the high real-time and robustness in path tracing control. This provides a certain theoretical basis for intelligent vehicle autonomous navigation tracking control, and lays the foundation for the vertical and lateral coupling control.

  18. The Lateral Tracking Control for the Intelligent Vehicle Based on Adaptive PID Neural Network

    PubMed Central

    Han, Gaining; Fu, Weiping; Wang, Wen; Wu, Zongsheng

    2017-01-01

    The intelligent vehicle is a complicated nonlinear system, and the design of a path tracking controller is one of the key technologies in intelligent vehicle research. This paper mainly designs a lateral control dynamic model of the intelligent vehicle, which is used for lateral tracking control. Firstly, the vehicle dynamics model (i.e., transfer function) is established according to the vehicle parameters. Secondly, according to the vehicle steering control system and the CARMA (Controlled Auto-Regression and Moving-Average) model, a second-order control system model is built. Using forgetting factor recursive least square estimation (FFRLS), the system parameters are identified. Finally, a neural network PID (Proportion Integral Derivative) controller is established for lateral path tracking control based on the vehicle model and the steering system model. Experimental simulation results show that the proposed model and algorithm have the high real-time and robustness in path tracing control. This provides a certain theoretical basis for intelligent vehicle autonomous navigation tracking control, and lays the foundation for the vertical and lateral coupling control. PMID:28556817

  19. Characteristics of an aerosol photometer while automatically controlling chamber dilution-air flow rate.

    PubMed

    O'Shaughnessy, P T; Hemenway, D R

    2000-10-01

    Trials were conducted to determine those factors that affect the accuracy of a direct-reading aerosol photometer when automatically controlling airflow rate within an exposure chamber to regulate airborne dust concentrations. Photometer response was affected by a shift in the aerosol size distribution caused by changes in chamber flow rate. In addition to a dilution effect, flow rate also determined the relative amount of aerosol lost to sedimentation within the chamber. Additional calculations were added to a computer control algorithm to compensate for these effects when attempting to automatically regulate flow based on a proportional-integral-derivative (PID) feedback control algorithm. A comparison between PID-controlled trials and those performed with a constant generator output rate and dilution-air flow rate demonstrated that there was no significant decrease in photometer accuracy despite the many changes in flow rate produced when using PID control. Likewise, the PID-controlled trials produced chamber aerosol concentrations within 1% of a desired level.

  20. Distribution, clinical features and molecular analysis of primary immunodeficiency diseases in Chinese children: a single-center study from 2005 to 2011.

    PubMed

    Zhang, Zhi-Yong; An, Yun-Fei; Jiang, Li-Ping; Liu, Wei; Liu, Da-Wei; Xie, Jing-Wen; Tang, Xue-Mei; Wang, Mo; Yang, Xi-Qiang; Zhao, Xiao-Dong

    2013-10-01

    Two hundred three children with genetically proven primary immunodeficiency diseases (PIDs) from 197 unrelated families were enrolled from January 2005 to December 2011. On the basis of criteria developed by the International Union of Immunological Societies, 79 patients were diagnosed as "other well-defined immunodeficiency syndromes" (38.9%), 62 (30.6%) with "predominant antibody deficiencies," 26 (12.8%) with "congenital defects of phagocyte," 25 (12.3%) with "T- and B-cell immunodeficiency" and 11 (5.4%) with "diseases of immune dysregulation." The median time to the diagnosis was 27.9 months and the patients had a wide range of clinical presentations. In addition, a total of 23 pathogenic genes were identified and 213 mutations were detected, including 42 novel mutations. With the increase in the awareness of PIDs and diagnostic competence, more PID patients will be diagnosed and we will be able to more accurately identify the frequency and the distribution of PIDs in the most populous country in the world.

  1. Characterizing psychopathy using DSM-5 personality traits.

    PubMed

    Strickland, Casey M; Drislane, Laura E; Lucy, Megan; Krueger, Robert F; Patrick, Christopher J

    2013-06-01

    Despite its importance historically and contemporarily, psychopathy is not recognized in the current Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revised (DSM-IV-TR). Its closest counterpart, antisocial personality disorder, includes strong representation of behavioral deviance symptoms but weak representation of affective-interpersonal features considered central to psychopathy. The current study evaluated the extent to which psychopathy and its distinctive facets, indexed by the Triarchic Psychopathy Measure, can be assessed effectively using traits from the dimensional model of personality pathology developed for DSM-5, operationalized by the Personality Inventory for DSM-5 (PID-5). Results indicate that (a) facets of psychopathy entailing impulsive externalization and callous aggression are well-represented by traits from the PID-5 considered relevant to antisocial personality disorder, and (b) the boldness facet of psychopathy can be effectively captured using additional PID-5 traits. These findings provide evidence that the dimensional model of personality pathology embodied in the PID-5 provides effective trait-based coverage of psychopathy and its facets.

  2. Oilfield flooding polymer

    DOEpatents

    Martin, Fred D.; Hatch, Melvin J.; Shepitka, Joel S.; Donaruma, Lorraine G.

    1986-01-01

    A monomer, polymers containing the monomer, and the use of the polymer in oilfield flooding is disclosed. The subject monomer is represented by the general formula: ##STR1## wherein: n is an integer from 0 to about 4; m is an integer from 0 to about 6; a is an integer equal to at least 1 except where m is equal to 0, a must equal 0 and where m is equal to 1, a must equal 0 or 1; p is an integer from 2 to about 10; b is an integer equal to at least 1 and is of sufficient magnitude that the ratio b/p is at least 0.2; and q is an integer from 0 to 2. The number of hydroxy groups in the monomer is believed to be critical, and therefore the sum of (a+b) divided by the sum (m+p) should be at least 0.2. The moieties linked to the acrylic nitrogen can be joined to provide a ringed structure.

  3. Dynamic PID loop control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pei, L.; Klebaner, A.; Theilacker, J.

    2011-06-01

    The Horizontal Test Stand (HTS) SRF Cavity and Cryomodule 1 (CM1) of eight 9-cell, 1.3GHz SRF cavities are operating at Fermilab. For the cryogenic control system, how to hold liquid level constant in the cryostat by regulation of its Joule-Thompson JT-valve is very important after cryostat cool down to 2.0 K. The 72-cell cryostat liquid level response generally takes a long time delay after regulating its JT-valve; therefore, typical PID control loop should result in some cryostat parameter oscillations. This paper presents a type of PID parameter self-optimal and Time-Delay control method used to reduce cryogenic system parameters oscillation.

  4. Outpatient management of pelvic inflammatory disease.

    PubMed

    Price, B; Martens, M

    2001-08-01

    Pelvic inflammatory disease (PID) is a spectrum of inflammatory disorders of the female genital tract involving at least the endrometrium and may include the fallopian tubes, ovaries, and pelvic cavity. Over 1 million women each year are treated for PID in the United States, and it is one of the most serious infections diagnosed in women due to its sequelae. Women with PID acutely experience pain and are at risk for sepsis; however, the significant increases in ectopic pregnancy and infertility are the most disturbing long-term complications. It most often is initiated with an infection by a sexually transmitted disease, but can also involve a variety of pathogenic aerobes and anaerobes secondarily.

  5. Load Frequency Control of AC Microgrid Interconnected Thermal Power System

    NASA Astrophysics Data System (ADS)

    Lal, Deepak Kumar; Barisal, Ajit Kumar

    2017-08-01

    In this paper, a microgrid (MG) power generation system is interconnected with a single area reheat thermal power system for load frequency control study. A new meta-heuristic optimization algorithm i.e. Moth-Flame Optimization (MFO) algorithm is applied to evaluate optimal gains of the fuzzy based proportional, integral and derivative (PID) controllers. The system dynamic performance is studied by comparing the results with MFO optimized classical PI/PID controllers. Also the system performance is investigated with fuzzy PID controller optimized by recently developed grey wolf optimizer (GWO) algorithm, which has proven its superiority over other previously developed algorithm in many interconnected power systems.

  6. A second-order accurate immersed boundary-lattice Boltzmann method for particle-laden flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Qiang; Fan, Liang-Shih, E-mail: fan.1@osu.edu

    A new immersed boundary-lattice Boltzmann method (IB-LBM) is presented for fully resolved simulations of incompressible viscous flows laden with rigid particles. The immersed boundary method (IBM) recently developed by Breugem (2012) [19] is adopted in the present method, development including the retraction technique, the multi-direct forcing method and the direct account of the inertia of the fluid contained within the particles. The present IB-LBM is, however, formulated with further improvement with the implementation of the high-order Runge–Kutta schemes in the coupled fluid–particle interaction. The major challenge to implement high-order Runge–Kutta schemes in the LBM is that the flow information suchmore » as density and velocity cannot be directly obtained at a fractional time step from the LBM since the LBM only provides the flow information at an integer time step. This challenge can be, however, overcome as given in the present IB-LBM by extrapolating the flow field around particles from the known flow field at the previous integer time step. The newly calculated fluid–particle interactions from the previous fractional time steps of the current integer time step are also accounted for in the extrapolation. The IB-LBM with high-order Runge–Kutta schemes developed in this study is validated by several benchmark applications. It is demonstrated, for the first time, that the IB-LBM has the capacity to resolve the translational and rotational motion of particles with the second-order accuracy. The optimal retraction distances for spheres and tubes that help the method achieve the second-order accuracy are found to be around 0.30 and −0.47 times of the lattice spacing, respectively. Simulations of the Stokes flow through a simple cubic lattice of rotational spheres indicate that the lift force produced by the Magnus effect can be very significant in view of the magnitude of the drag force when the practical rotating speed of the spheres is encountered. This finding may lead to more comprehensive studies of the effect of the particle rotation on fluid–solid drag laws. It is also demonstrated that, when the third-order or the fourth-order Runge–Kutta scheme is used, the numerical stability of the present IB-LBM is better than that of all methods in the literature, including the previous IB-LBMs and also the methods with the combination of the IBM and the traditional incompressible Navier–Stokes solver. - Highlights: • The IBM is embedded in the LBM using Runge–Kutta time schemes. • The effectiveness of the present IB-LBM is validated by benchmark applications. • For the first time, the IB-LBM achieves the second-order accuracy. • The numerical stability of the present IB-LBM is better than previous methods.« less

  7. Primary immunodeficiency association with systemic lupus erythematosus: review of literature and lessons learned by the Rheumatology Division of a tertiary university hospital at São Paulo, Brazil.

    PubMed

    Errante, Paolo Ruggero; Perazzio, Sandro Félix; Frazão, Josias Brito; da Silva, Neusa Pereira; Andrade, Luis Eduardo Coelho

    2016-01-01

    Primary immunodeficiency disorders (PID) represent a heterogeneous group of diseases resulting from inherited defects in the development, maturation and normal function of immune cells; thus, turning individuals susceptible to recurrent infections, allergy, autoimmunity, and malignancies. In this retrospective study, autoimmune diseases (AIDs), in special systemic lupus erythematosus (SLE) which arose associated to the course of PID, are described. Classically, the literature describes three groups of PID associated with SLE: (1) deficiency of Complement pathway components, (2) defects in immunoglobulin synthesis, and (3) chronic granulomatous disease (CGD). Currently, other PID have been described with clinical manifestation of SLE, such as Wiskott-Aldrich syndrome (WAS), autoimmune polyendocrinopathy candidiasis ectodermal dystrophy (APECED), autoimmune lymphoproliferative syndrome (ALPS) and idiopathic CD4(+) lymphocytopenia. Also we present findings from an adult cohort from the outpatient clinic of the Rheumatology Division of Universidade Federal de São Paulo. The PID manifestations found by our study group were considered mild in terms of severity of infections and mortality in early life. Thus, it is possible that some immunodeficiency states are compatible with survival regarding infectious susceptibility; however these states might represent a strong predisposing factor for the development of immune disorders like those observed in SLE. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.

  8. A Paper-and-Pencil gcd Algorithm for Gaussian Integers

    ERIC Educational Resources Information Center

    Szabo, Sandor

    2005-01-01

    As with natural numbers, a greatest common divisor of two Gaussian (complex) integers "a" and "b" is a Gaussian integer "d" that is a common divisor of both "a" and "b". This article explores an algorithm for such gcds that is easy to do by hand.

  9. Influence of non-integer-order derivatives on unsteady unidirectional motions of an Oldroyd-B fluid with generalized boundary conditions

    NASA Astrophysics Data System (ADS)

    Zafar, A. A.; Riaz, M. B.; Shah, N. A.; Imran, M. A.

    2018-03-01

    The objective of this article is to study some unsteady Couette flows of an Oldroyd-B fluid with non-integer derivatives. The fluid fills an annular region of two infinite co-axial circular cylinders. Flows are due to the motion of the outer cylinder, that rotates about its axis with an arbitrary time-dependent velocity while the inner cylinder is held fixed. Closed form solutions of dimensionless velocity field and tangential tension are obtained by means of the finite Hankel transform and the theory of Laplace transform for fractional calculus. Several results in the literature including the rotational flows through an infinite cylinder can be obtained as limiting cases of our general solutions. Finally, the control of the fractional framework on the dynamics of fluid is analyzed by numerical simulations and graphical illustrations.

  10. Robust design of (s, S) inventory policy parameters in supply chains with demand and lead time uncertainties

    NASA Astrophysics Data System (ADS)

    Karimi Movahed, Kamran; Zhang, Zhi-Hai

    2015-09-01

    Demand and lead time uncertainties have significant effects on supply chain behaviour. In this paper, we present a single-product three-level multi-period supply chain with uncertain demands and lead times by using robust techniques to study the managerial insights of the supply chain inventory system under uncertainty. We formulate this problem as a robust mixed-integer linear program with minimised expected cost and total cost variation to determine the optimal (s, S) values of the inventory parameters. Several numerical studies are performed to investigate the supply chain behaviour. Useful guidelines for the design of a robust supply chain are also provided. Results show that the order variance and the expected cost in a supply chain significantly increase when the manufacturer's review period is an integer ratio of the distributor's and the retailer's review periods.

  11. Analytical estimation of the correlation dimension of integer lattices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lacasa, Lucas, E-mail: l.lacasa@qmul.ac.uk; Gómez-Gardeñes, Jesús, E-mail: gardenes@gmail.com; Departamento de Fisica de la Materia Condensada, Universidad de Zaragoza, Zaragoza

    2014-12-01

    Recently [L. Lacasa and J. Gómez-Gardeñes, Phys. Rev. Lett. 110, 168703 (2013)], a fractal dimension has been proposed to characterize the geometric structure of networks. This measure is an extension to graphs of the so called correlation dimension, originally proposed by Grassberger and Procaccia to describe the geometry of strange attractors in dissipative chaotic systems. The calculation of the correlation dimension of a graph is based on the local information retrieved from a random walker navigating the network. In this contribution, we study such quantity for some limiting synthetic spatial networks and obtain analytical results on agreement with the previouslymore » reported numerics. In particular, we show that up to first order, the correlation dimension β of integer lattices ℤ{sup d} coincides with the Haussdorf dimension of their coarsely equivalent Euclidean spaces, β = d.« less

  12. Errors in the estimation of approximate entropy and other recurrence-plot-derived indices due to the finite resolution of RR time series.

    PubMed

    García-González, Miguel A; Fernández-Chimeno, Mireya; Ramos-Castro, Juan

    2009-02-01

    An analysis of the errors due to the finite resolution of RR time series in the estimation of the approximate entropy (ApEn) is described. The quantification errors in the discrete RR time series produce considerable errors in the ApEn estimation (bias and variance) when the signal variability or the sampling frequency is low. Similar errors can be found in indices related to the quantification of recurrence plots. An easy way to calculate a figure of merit [the signal to resolution of the neighborhood ratio (SRN)] is proposed in order to predict when the bias in the indices could be high. When SRN is close to an integer value n, the bias is higher than when near n - 1/2 or n + 1/2. Moreover, if SRN is close to an integer value, the lower this value, the greater the bias is.

  13. Comparative performance evaluation of transform coding in image pre-processing

    NASA Astrophysics Data System (ADS)

    Menon, Vignesh V.; NB, Harikrishnan; Narayanan, Gayathri; CK, Niveditha

    2017-07-01

    We are in the midst of a communication transmute which drives the development as largely as dissemination of pioneering communication systems with ever-increasing fidelity and resolution. Distinguishable researches have been appreciative in image processing techniques crazed by a growing thirst for faster and easier encoding, storage and transmission of visual information. In this paper, the researchers intend to throw light on many techniques which could be worn at the transmitter-end in order to ease the transmission and reconstruction of the images. The researchers investigate the performance of different image transform coding schemes used in pre-processing, their comparison, and effectiveness, the necessary and sufficient conditions, properties and complexity in implementation. Whimsical by prior advancements in image processing techniques, the researchers compare various contemporary image pre-processing frameworks- Compressed Sensing, Singular Value Decomposition, Integer Wavelet Transform on performance. The paper exposes the potential of Integer Wavelet transform to be an efficient pre-processing scheme.

  14. Natural variation of rice blast resistance gene Pi-d2

    USDA-ARS?s Scientific Manuscript database

    Studying natural variation of rice resistance (R) genes in cultivated and wild rice relatives can predict resistance stability to rice blast fungus. In the present study, the protein coding regions of rice R gene Pi-d2 in 35 rice accessions of subgroups, aus (AUS), indica (IND), temperate japonica (...

  15. Design of a PID Controller for a PCR Micro Reactor

    ERIC Educational Resources Information Center

    Dinca, M. P.; Gheorghe, M.; Galvin, P.

    2009-01-01

    Proportional-integral-derivative (PID) controllers are widely used in process control, and consequently they are described in most of the textbooks on automatic control. However, rather than presenting the overall design process, the examples given in such textbooks are intended to illuminate specific focused aspects of selection, tuning and…

  16. A new VLSI complex integer multiplier which uses a quadratic-polynomial residue system with Fermat numbers

    NASA Technical Reports Server (NTRS)

    Truong, T. K.; Hsu, I. S.; Chang, J. J.; Shyu, H. C.; Reed, I. S.

    1986-01-01

    A quadratic-polynomial Fermat residue number system (QFNS) has been used to compute complex integer multiplications. The advantage of such a QFNS is that a complex integer multiplication requires only two integer multiplications. In this article, a new type Fermat number multiplier is developed which eliminates the initialization condition of the previous method. It is shown that the new complex multiplier can be implemented on a single VLSI chip. Such a chip is designed and fabricated in CMOS-pw technology.

  17. A new VLSI complex integer multiplier which uses a quadratic-polynomial residue system with Fermat numbers

    NASA Technical Reports Server (NTRS)

    Shyu, H. C.; Reed, I. S.; Truong, T. K.; Hsu, I. S.; Chang, J. J.

    1987-01-01

    A quadratic-polynomial Fermat residue number system (QFNS) has been used to compute complex integer multiplications. The advantage of such a QFNS is that a complex integer multiplication requires only two integer multiplications. In this article, a new type Fermat number multiplier is developed which eliminates the initialization condition of the previous method. It is shown that the new complex multiplier can be implemented on a single VLSI chip. Such a chip is designed and fabricated in CMOS-Pw technology.

  18. Elasticity of fractal materials using the continuum model with non-integer dimensional space

    NASA Astrophysics Data System (ADS)

    Tarasov, Vasily E.

    2015-01-01

    Using a generalization of vector calculus for space with non-integer dimension, we consider elastic properties of fractal materials. Fractal materials are described by continuum models with non-integer dimensional space. A generalization of elasticity equations for non-integer dimensional space, and its solutions for the equilibrium case of fractal materials are suggested. Elasticity problems for fractal hollow ball and cylindrical fractal elastic pipe with inside and outside pressures, for rotating cylindrical fractal pipe, for gradient elasticity and thermoelasticity of fractal materials are solved.

  19. Sixth-Grade Students' Reasoning on the Order Relation of Integers as Influenced by Prior Experience: An Inferentialist Analysis

    ERIC Educational Resources Information Center

    Schindler, Maike; Hußmann, Stephan; Nilsson, Per; Bakker, Arthur

    2017-01-01

    Negative numbers are among the first formalizations students encounter in their mathematics learning that clearly differ from out-of-school experiences. What has not sufficiently been addressed in previous research is the question of how students draw on their prior experiences when reasoning on negative numbers and how they infer from these…

  20. Origini Concettuali di Errori che si Riscontrano Nel Confrontare Numeri Decimali e Frazioni=Conceptual Sources of Difficulties Concerning the Ordering of Decimal Numbers and the Comparison of Fractions.

    ERIC Educational Resources Information Center

    Bonotto, C.

    1993-01-01

    Examined fifth-grade students' survey responses to investigate incorrect rules that derive from children's efforts to interpret decimals as integers or as fractions. Regarding fractions, difficulties arise because only the whole-part approach to fractions is presented in elementary school. (Author/MDH)

Top