NASA Astrophysics Data System (ADS)
Telichev, Igor; Cherniaev, Aleksandr
Gas-filled pressure vessels are extensively used in spacecraft onboard systems. During operation on the orbit they exposed to the space debris environment. Due to high energies they contain, pressure vessels have been recognized as the most critical spacecraft components requiring protection from orbital debris impact. Major type of pressurized containers currently used in spacecraft onboard systems is composite overwrapped pressure vessels (COPVs) manufactured by filament winding. In the present work we analyze the structural integrity of vessels of this kind in case of orbital debris impact at velocities ranging from 2 to 10 km/s. Influence of such parameters as projectile energy, shielding standoff, internal pressure and filament winding pattern on COPVs structural integrity has been investigated by means of numerical and physical experiments.
Borg, Jael; Mizzi, Stephen; Formosa, Cynthia
2018-05-19
Clinicians currently rely on observational clinical data pertaining to the biomechanics of the diabetic foot. However, advances in technology can objectively describe this. A thorough understanding of the functional and mechanical consequences following trans-tibial amputations is lacking. Does a trans-tibial prostheses significantly increase peak plantar pressures and pressure time integrals in the intact foot of patients with type-2 diabetes and neuropathy? A prospective quantitative matched-subject design was employed. Twenty participants living with diabetes and peripheral sensory neuropathy were recruited. Ten participants presented with a trans-tibial amputation and 10 had intact feet. Participants were matched for gender, age, foot type and BMI. Peak plantar pressure and pressure time integral data were recorded using the Tekscan HR™ pressure mat system, using the two-step gait protocol. The Shapiro-Wilk test was used to determine normality of data. The Independent Samples t-test and the Mann Whitney U test were carried out to reject the null hypothesis. Although no significant differences (p < 0.05) in mean peak plantar pressures were observed in all the foot masks analysed between the amputee and the control group, a significant difference (p = 0.002) in mean pressure time integrals was recorded with highest pressure time integral (PTI) values under the 2nd-4th metatarsophalangeal joint (MTP joint) for the trans-tibial amputee group. Cumulative exposure of both pressure and time can lead to tissue damage. PTI could be considered as an important contributory factor in determining ulcer formation. Elevated PTI under the 2nd-4th MTP joints sustained in the intact contralateral limb in patients using below knee prosthesis could possibly be due to gait alterations in this population. The preservation of the contralateral limb is of great concern and importance as this might impact patient's mobility and quality of life. Copyright © 2018 Elsevier B.V. All rights reserved.
Aortic stiffness is associated with white matter integrity in patients with type 1 diabetes.
Tjeerdema, Nathanja; Van Schinkel, Linda D; Westenberg, Jos J; Van Elderen, Saskia G; Van Buchem, Mark A; Smit, Johannes W; Van der Grond, Jeroen; De Roos, Albert
2014-09-01
To assess the association between aortic pulse wave velocity (PWV) as a marker of arterial stiffness and diffusion tensor imaging of brain white matter integrity in patients with type 1 diabetes using advanced magnetic resonance imaging (MRI) technology. Forty-one patients with type 1 diabetes (23 men, mean age 44 ± 12 years, mean diabetes duration 24 ± 13 years) were included. Aortic PWV was assessed using through-plane velocity-encoded MRI. Brain diffusion tensor imaging (DTI) measurements were performed on 3-T MRI. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were calculated for white and grey matter integrity. Pearson correlation and multivariable linear regression analyses including cardiovascular risk factors as covariates were assessed. Multivariable linear regression analyses revealed that aortic PWV is independently associated with white matter integrity FA (β = -0.777, p = 0.008) in patients with type 1 diabetes. This effect was independent of age, gender, mean arterial pressure, body mass index, smoking, duration of diabetes and glycated haemoglobin levels. Aortic PWV was not significantly related to grey matter integrity. Our data suggest that aortic stiffness is independently associated with reduced white matter integrity in patients with type 1 diabetes. Aortic stiffness is associated with brain injury. Aortic stiffness exposes small vessels to high pressure fluctuations and flow. Aortic stiffness is associated with microvascular brain injury in diabetes. This suggests a vascular contribution to early subtle microstructural deficits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pugh, C.E.
2001-01-29
Numerous large-scale fracture experiments have been performed over the past thirty years to advance fracture mechanics methodologies applicable to thick-wall pressure vessels. This report first identifies major factors important to nuclear reactor pressure vessel (RPV) integrity under pressurized thermal shock (PTS) conditions. It then covers 20 key experiments that have contributed to identifying fracture behavior of RPVs and to validating applicable assessment methodologies. The experiments are categorized according to four types of specimens: (1) cylindrical specimens, (2) pressurized vessels, (3) large plate specimens, and (4) thick beam specimens. These experiments were performed in laboratories in six different countries. This reportmore » serves as a summary of those experiments, and provides a guide to references for detailed information.« less
Foot Type Biomechanics Part 1: Structure and Function of the Asymptomatic Foot
Hillstrom, Howard J.; Song, Jinsup; Kraszewski, Andrew P.; Hafer, Jocelyn F.; Mootanah, Rajshree; Dufour, Alyssa B.; PT, Betty (Shingpui) Chow; Deland, Jonathan T.
2012-01-01
Background Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? Aim To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Methods Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMatII gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pairwise comparisons. Results Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Conclusions Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. PMID:23107625
Foot type biomechanics part 1: structure and function of the asymptomatic foot.
Hillstrom, Howard J; Song, Jinsup; Kraszewski, Andrew P; Hafer, Jocelyn F; Mootanah, Rajshree; Dufour, Alyssa B; Chow, Betty Shingpui; Deland, Jonathan T
2013-03-01
Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMat II gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pair wise comparisons. Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. Copyright © 2012 Elsevier B.V. All rights reserved.
Ceramic MEMS Designed for Wireless Pressure Monitoring in the Industrial Environment
Pavlin, Marko; Belavic, Darko; Novak, Franc
2012-01-01
This paper presents the design of a wireless pressure-monitoring system for harsh-environment applications. Two types of ceramic pressure sensors made with a low-temperature cofired ceramic (LTCC) were considered. The first type is a piezoresistive strain gauge pressure sensor. The second type is a capacitive pressure sensor, which is based on changes of the capacitance values between two electrodes: one electrode is fixed and the other is movable under an applied pressure. The design was primarily focused on low power consumption. Reliable operation in the presence of disturbances, like electromagnetic interference, parasitic capacitances, etc., proved to be contradictory constraints. A piezoresistive ceramic pressure sensor with a high bridge impedance was chosen for use in a wireless pressure-monitoring system and an acceptable solution using energy-harvesting techniques has been achieved. The described solution allows for the integration of a sensor element with an energy harvester that has a printed thick-film battery and complete electronics in a single substrate packaged inside a compact housing. PMID:22368471
Nakadate, Hiromichi; Inuzuka, Koji; Akanuma, Suguru; Kakuta, Akira; Aomura, Shigeru
2014-04-16
Intracranial pressure changes during head impact cause brain injuries such as vasogenic edema and cerebral contusion. However, the influence of impulsive pressure on endothelial function has not yet been fully studied in vitro. In this study, we developed a pressure loading device that produced positive and negative pressures by modifying an in vitro fluid percussion model and examined the effects of the amplitude and duration of the pressures on endothelial permeability. Human umbilical vein endothelial cells were subjected to three types of positive pressure (average amplitude/average duration of 352 kPa/23 ms, 73 kPa/27 ms, and 70 kPa/44 ms) and three types of negative pressure (-72 kPa/41 ms, -67 kPa/104 ms, and -91 kPa/108 ms), and the transendothelial electrical resistance (TEER) was measured between 15 min and 24 h after pressure loading for quantifying the formation of an integral monolayer of endothelial cells. After loading, vascular endothelial- (VE-) cadherin, an endothelium-specific cell-cell adhesion molecule involved in endothelial barrier function, was stained and observed using fluorescence microscopy. The pressure loading device could produce positive pressure pulses with amplitudes of 53-1348 kPa and durations of 9-29.1 ms and negative pressure pulses with amplitudes of -52 - -93 kPa and durations of 42.9-179.5 ms. The impulsive pressure reduced the TEER associated with the change in VE-cadherin localization. Additionally, TEER decreased considerably at 15 min and 6 h post-loading, with these changes being significant in positive pressure with larger amplitude and shorter duration and in all types of negative pressures compared to pre-loading. The changes in intracranial pressure during head impact impair endothelial barrier function by the disruption of the integrity of endothelial cell-cell junctions, and the degree of increase in endothelial permeability depends on the amplitude, duration, and direction (compressive and tensile) of the impulsive pressure.
NASA Astrophysics Data System (ADS)
Kenok, R.; Jomdecha, C.; Jirarungsatian, C.
The aim of this paper is to study the acoustic emission (AE) parameters obtained from CNG cylinders during pressurization. AE from flaw propagation, material integrity, and pressuring of cylinder was the main objective for characterization. CNG cylinders of ISO 11439, resin fully wrapped type and metal liner type, were employed to test by hydrostatic stressing. The pressure was step increased until 1.1 time of operating pressure. Two AE sensors, resonance frequency of 150 kHz, were mounted on the cylinder wall to detect the AE throughout the testing. From the experiment results, AE can be detected from pressuring rate, material integrity, and flaw propagation from the cylinder wall. AE parameters including Amplitude, Count, Energy (MARSE), Duration and Rise time were analyzed to distinguish the AE data. The results show that the AE of flaw propagation was different in character from that of pressurization. Especially, AE detected from flaws of resin wrapped and metal liner was significantly different. To locate the flaw position, both the AE sensors can be accurately used to locate the flaw propagation in a linear pattern. The error was less than ±5 cm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... its carrying vessel's hull. (c) Gravity. Tanks having a design pressure (as described in Part 54 of... where stress analysis is neither readily nor completely determinate. (Integral tanks are of the gravity.... Independent gravity tanks which are of normal pressure vessel configuration (i.e., bodies of revolution, in...
Raabe, A; Stöckel, R; Hohrein, D; Schöche, J
1998-01-01
The failure of intraventricular pressure measurement in cases of catheter blockage or dislodgement is thought to be eliminated by using intraventricular microtransducers. We report on an avoidable methodological error that may affect the reliability of intraventricular pressure measurement with these devices. Intraventricular fiberoptic or solid-state devices were implanted in 43 patients considered to be at risk for developing catheter occlusion. Two different types were used, i.e., devices in which the transducer is placed inside the ventriculostomy catheter (Type A) and devices in which the transducer is integrated in the external surface of the catheter (Type B). Type A devices were used in 15 patients and Type B devices in 28 patients. Pressure recordings were checked at bedside for the validity and reliability of the measurement. Of the 15 patients treated with Type A devices, no reliable pressure recordings were able to be obtained in three patients in whom ventricular punctures were not successful. In 4 of the remaining 12 patients, periods of erroneous pressure readings were detected. After opening of cerebrospinal fluid drainage, all Type A devices failed to reflect real intraventricular pressure. In patients treated with Type B devices, no erroneous pressure recordings were able to be identified, irrespective of whether cerebrospinal fluid drainage was performed. Even when ventricular puncture failed, pressure measurement was correct each time. Transducers that are simply placed inside the ventriculostomy catheter require fluid-coupling. They may fail, either during cerebrospinal fluid drainage or when the catheter is blocked or placed within the parenchyma.
46 CFR 151.15-1 - Unknown Title
Code of Federal Regulations, 2014 CFR
2014-10-01
... vessel's hull. (c) Gravity. Tanks having a design pressure (as described in Part 54 of this chapter) not... analysis is neither readily nor completely determinate. (Integral tanks are of the gravity type.) (d... gravity tanks which are of normal pressure vessel configuration (i.e., bodies of revolution, in which the...
Pan, Zhao; Whitehead, Jared; Thomson, Scott; Truscott, Tadd
2016-08-01
Obtaining pressure field data from particle image velocimetry (PIV) is an attractive technique in fluid dynamics due to its noninvasive nature. The application of this technique generally involves integrating the pressure gradient or solving the pressure Poisson equation using a velocity field measured with PIV. However, very little research has been done to investigate the dynamics of error propagation from PIV-based velocity measurements to the pressure field calculation. Rather than measure the error through experiment, we investigate the dynamics of the error propagation by examining the Poisson equation directly. We analytically quantify the error bound in the pressure field, and are able to illustrate the mathematical roots of why and how the Poisson equation based pressure calculation propagates error from the PIV data. The results show that the error depends on the shape and type of boundary conditions, the dimensions of the flow domain, and the flow type.
2014-01-01
Background Intracranial pressure changes during head impact cause brain injuries such as vasogenic edema and cerebral contusion. However, the influence of impulsive pressure on endothelial function has not yet been fully studied in vitro. In this study, we developed a pressure loading device that produced positive and negative pressures by modifying an in vitro fluid percussion model and examined the effects of the amplitude and duration of the pressures on endothelial permeability. Methods Human umbilical vein endothelial cells were subjected to three types of positive pressure (average amplitude/average duration of 352 kPa/23 ms, 73 kPa/27 ms, and 70 kPa/44 ms) and three types of negative pressure (−72 kPa/41 ms, −67 kPa/104 ms, and −91 kPa/108 ms), and the transendothelial electrical resistance (TEER) was measured between 15 min and 24 h after pressure loading for quantifying the formation of an integral monolayer of endothelial cells. After loading, vascular endothelial- (VE-) cadherin, an endothelium-specific cell-cell adhesion molecule involved in endothelial barrier function, was stained and observed using fluorescence microscopy. Results The pressure loading device could produce positive pressure pulses with amplitudes of 53–1348 kPa and durations of 9–29.1 ms and negative pressure pulses with amplitudes of −52–−93 kPa and durations of 42.9–179.5 ms. The impulsive pressure reduced the TEER associated with the change in VE-cadherin localization. Additionally, TEER decreased considerably at 15 min and 6 h post-loading, with these changes being significant in positive pressure with larger amplitude and shorter duration and in all types of negative pressures compared to pre-loading. Conclusions The changes in intracranial pressure during head impact impair endothelial barrier function by the disruption of the integrity of endothelial cell-cell junctions, and the degree of increase in endothelial permeability depends on the amplitude, duration, and direction (compressive and tensile) of the impulsive pressure. PMID:24739360
Miniature piezoresistive solid state integrated pressure sensors
NASA Technical Reports Server (NTRS)
Kahng, S. K.
1980-01-01
The characteristics of silicon pressure sensors with an ultra-small diaphragm are described. The pressure sensors utilize rectangular diaphragm as small as 0.0127 x 0.0254 cm and a p-type Wheatstone bridge consisting of diffused piezoresistive elements, 0.000254 cm by 0.00254 cm. These sensors exhibit as high as 0.5 MHz natural frequency and 1 mV/V/psi pressure sensitivity. Fabrication techniques and high frequency results from shock tube testing and low frequency comparison with microphones are presented.
Bergstra, S A; Kluitenberg, B; Dekker, R; Bredeweg, S W; Postema, K; Van den Heuvel, E R; Hijmans, J M; Sobhani, S
2015-07-01
Minimalist running shoes have been proposed as an alternative to barefoot running. However, several studies have reported cases of forefoot stress fractures after switching from standard to minimalist shoes. Therefore, the aim of the current study was to investigate the differences in plantar pressure in the forefoot region between running with a minimalist shoe and running with a standard shoe in healthy female runners during overground running. Randomized crossover design. In-shoe plantar pressure measurements were recorded from eighteen healthy female runners. Peak pressure, maximum mean pressure, pressure time integral and instant of peak pressure were assessed for seven foot areas. Force time integral, stride time, stance time, swing time, shoe comfort and landing type were assessed for both shoe types. A linear mixed model was used to analyze the data. Peak pressure and maximum mean pressure were higher in the medial forefoot (respectively 13.5% and 7.46%), central forefoot (respectively 37.5% and 29.2%) and lateral forefoot (respectively 37.9% and 20.4%) for the minimalist shoe condition. Stance time was reduced with 3.81%. No relevant differences in shoe comfort or landing strategy were found. Running with a minimalist shoe increased plantar pressure without a change in landing pattern. This increased pressure in the forefoot region might play a role in the occurrence of metatarsal stress fractures in runners who switched to minimalist shoes and warrants a cautious approach to transitioning to minimalist shoe use. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
In-reactor performance of LWR-type tritium target rods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanning, D.D.; Paxton, M.M.; Crumbaugh, L.
Pacific Northwest Laboratory has conducted several 1-yr irradiation tests of light water reactor-type tritium target rods. These tests have been sponsored by the U.S. Department of Energy's Office of New Production Reactors. The first test, designated water capsule-1 (WC-1), was conducted in the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory from November 1989 to December 1990. The test vehicle contained a single 4-ft target rod within a pressurized water capsule. The capsule maintained the rod at pressurized water reactor (PWR)-type water temperature and pressure conditions. Posttest nondestructive examinations of the WC-1 rod involved visual examinations, dimensional checks,more » gamma scanning, and neutron radiography. The results indicate that the rod maintained the integrity of its pressure seal and was otherwise unaltered both mechanically and dimensionally by its irradiation and posttest handling.« less
Partial recovery of peristalsis after myotomy for achalasia; more the rule than the exception
Roman, Sabine; Kahrilas, Peter J; Mion, François; Nealis, Thomas B; Soper, Nathaniel J; Poncet, Gilles; Nicodème, Frédéric; Hungness, Eric; Pandolfino, John E
2013-01-01
Hypothesis: Myotomy that alleviates the esophagogastric junction (EGJ) outflow obstruction in achalasia might improve peristalsis. Design: Retrospective study Setting: Two tertiary hospitals (Chicago, USA and Lyon, France) Patients: Thirty patients (18 males; mean age 43 years, range 17-78) were included from 2004 to 2012: 8 type 1 achalasia (27%), 17 type 2 (57%) and 5 type 3 (16%) according to the Chicago Classification. Interventions: Esophageal high resolution manometry (HRM) before and after laparoscopic or endoscopic myotomy. Main outcomes measures: The integrity of peristalsis was characterized as intact, weak, frequent failed, absent, or premature contractions. Results: Whereas peristaltic fragments were evident only in patients with type 3 achalasia before treatment, intact, weak, or frequent failed peristalsis was encountered in 63% of type 1, 47% of type 2 and 80% of type 3 achalasia after myotomy. One type 3 patient had distal esophageal spasm after treatment. In patients with a post-myotomy integrated relaxation pressure (IRP) <15 mmHg, only 10 (40%) persisted in having absent peristalsis. Panesophageal pressurization disappeared after myotomy in 16 of 19 patients. In the 5 patients with post-myotomy IRP >15 mmHg, 4 had weak peristalsis and one had absent peristalsis. Conclusion: Reduction or normalization of the EGJ relaxation pressure achieved by myotomy in achalasia patients was associated with partial recovery of peristalsis in some patients suggesting that the disease process progresses from the EGJ to the esophageal body. Whether or not the return of peristalsis is predictive of an improved therapeutic outcome requires further study. PMID:23426591
Progressive Damage and Fracture of Unstiffened and Stiffened Composite Pressure Vessels
NASA Technical Reports Server (NTRS)
Minnetyan, Levon; Gotsis, Pascal K.; Chamis, Christos C.
1997-01-01
Structural durability and damage tolerance characteristics of pressurized graphite/epoxy laminated thin composite cylinders are investigated via computational simulation. Both unstiffened and integral hoop stiffened cylinders are considered. A computer code is utilized for the simulation of composite structural degradation under loading. Damage initiation, growth, accumulation, and propagation to structural fracture are included in the simulation. The increase of burst pressure due to hoop stiffening is quantified. Results demonstrate the significance of the type and size of local defects on the structural durability of pressurized composite cylindrical shells.
A preliminary objective evaluation of leprosy footwear using in-shoe pressure measurement.
Linge, K
1996-01-01
The primary function of leprosy shoes, insoles and podiatric orthoses is to provide an underfoot environment capable of distributing the inevitable vertical forces, so reducing areas of peak pressure and ideally the period through which they are applied. Many patients with Hansen's disease have both skeletal deformity and anesthetised feet and the presence of high plantar pressures is the key reason for foot ulceration. This objective investigation using in-shoe dynamic pressure measurements showed that the addition of a shank to control insole rigidity reduced the overall peak pressures under the foot. When a deep canvas shoe was used to test single- and double-thickness insoles of two different types of material it was found in each case that the double-thickness mode was advantageous overall. Microcellular rubber insoles in two types of leprosy shoe were replaced by the polymer Poron. The Poron proved to be superior to both microcellular rubbers. The peak pressure and pressure-time integral should be considered as complimentary variables when determining the efficacy of footwear.
A comparative study of MOEM pressure sensors using MZI, DC, and racetrack resonator IO structures
NASA Astrophysics Data System (ADS)
Selvarajan, A.; Pattnaik, Prasant Kumar; Badrinarayana, T.; Srinivas, T.
2006-03-01
In recent years micro-electro-mechanical system (MEMS) sensors have drawn considerable attention due to their attraction in terms of miniaturization, batch fabrication and ease of integration with the required electronics circuitry. Micro-opto-electro-mechanical (MOEM) devices and systems, based on the principles of integrated optics and micromachining technology on silicon have immense potential for sensor applications. Employing optical techniques have important advantages such as functionality, large bandwidth and higher sensitivity. Pressure sensing is currently the most lucrative market for solid-state micro sensors. Pressure sensing using micromachined structures utilize the changes induced in either the resistive or capacitive properties of the electro-mechanical structure by the impressed pressure. Integrated optical pressure sensors can utilize the changes to the amplitude, phase, refractive index profile, optical path length, or polarization of the lightwave by the external pressure. In this paper we compare the performance characteristics of three types of MOEM pressure sensors based on Mach-Zehnder Interferometer (MZI), Directional Coupler (DC) and racetrack resonator (RR) integrated optical geometries. The first two configurations measure the pressure changes through a change in optical intensity while the third one measures the same in terms of frequency or wavelength change. The analysis of each sensors has been carried out in terms of mechanical and optical models and their interrelationship through optomechanical coupling. For a typical diaphragm of size 2mm × 1mm × 20 μm, normalized pressure sensitivity of 18.35 μW/mW/kPa, 29.37 μW/mW/kPa and 2.26 pm/kPa in case of MZI, DC and RR devices have been obtained respectively. The noise performance of these devices are also presented.
Numerical evaluation of propeller noise including nonlinear effects
NASA Technical Reports Server (NTRS)
Korkan, K. D.; Von Lavante, E.; Bober, L. J.
1986-01-01
Propeller noise in the acoustic near field is presently determined through the integration of the pressure-time history in the tangential direction of a numerically generated flowfield around a propfan of SR-3 type, including the shock wave system in the vicinity of the propeller tip. This acoustic analysis yields overall sound pressure levels, and the associated frequency spectra, as a function of observer location.
Discontinuity stresses in metallic pressure vessels
NASA Technical Reports Server (NTRS)
1971-01-01
The state of the art, criteria, and recommended practices for the theoretical and experimental analyses of discontinuity stresses and their distribution in metallic pressure vessels for space vehicles are outlined. The applicable types of pressure vessels include propellant tanks ranging from main load-carrying integral tank structure to small auxiliary tanks, storage tanks, solid propellant motor cases, high pressure gas bottles, and pressurized cabins. The major sources of discontinuity stresses are discussed, including deviations in geometry, material properties, loads, and temperature. The advantages, limitations, and disadvantages of various theoretical and experimental discontinuity analysis methods are summarized. Guides are presented for evaluating discontinuity stresses so that pressure vessel performance will not fall below acceptable levels.
Integral flange design program. [procedure for computing stresses
NASA Technical Reports Server (NTRS)
Wilson, J. F.
1974-01-01
An automated interactive flange design program utilizing an electronic desk top calculator is presented. The program calculates the operating and seating stresses for circular flanges of the integral or optional type subjected to internal pressure. The required input information is documented. The program provides an automated procedure for computing stresses in selected flange geometries for comparison to the allowable code values.
2013-01-01
Background Although palatal augmentation prostheses (PAPs) can improve dysphagia, their application is compromised in the absence of maxillary abutment teeth. Experimental lingual plates (ELPs) used for raising the tongue may be employed as alternative to PAPs. Methods Influence of different ELP designs, plateau (P–type) and drop-shaped (D–type), on the intra–oral pressure during swallowing were tested. Eleven healthy dentate volunteers, with a mean age of 35.5±10.5 years, participated in this study. Tongue pressure on the hard palate was measured using an ultra-thin sensor sheet with five measuring points, whilst performing dry, 5–ml and 15–ml water swallows, with and without the ELPs in situ. Additional pressure sensors were installed in the lingual aspects of the ELPs, and on the vestibular aspect of the lower molars for measuring sublingual and oral vestibule pressures, respectively. Each measurement was recorded thrice. A repeated measures ANOVA was employed to verify differences in duration, maximal magnitude and integrated value for the different experimental situations. Tukey’s post hoc test was performed for comparison testing. Statistical significance was set at p<0.05. Results The sequence of tongue–palate contact on the median line of the hard palate without ELPs was maintained, except for the 15 ml P–type swallow. Tongue pressure started earlier with the D–type but reached its peak nearly at the same time as without ELPs. The peak magnitude and cumulative tongue pressure against the hard palate decreased by wearing ELPs (p<0.05), but was inconsistent between the two types of ELPs and for the different swallowing volumes. Both, maximum and cumulative vestibular pressures were mostly similar or larger with P–type than that with D–type. Conclusion D-type and P-type ELPs seem to have the inverse effect of PAPs on the palatal tongue pressure during swallowing. These first counterintuitive findings do not yet justify rejecting the basic rationale of using ELPs for the treatment of dysphagia; hence a rather biologically designed piezographic lingual plate may be more appropriate. PMID:23816202
Study on the intrinsic defects in ZnO by combing first-principle and thermodynamic calculations
NASA Astrophysics Data System (ADS)
Ma, Changmin; Liu, Tingyu; Chang, Qiuxiang
2015-11-01
In this paper, the intrinsic point defects in ZnO crystal have been studied by the approach that integrates first-principles, thermodynamic calculations and the contributions of vibrational entropy. With temperature increasing and oxygen partial pressure decreasing, the formation energies of oxygen vacancy (VO), zinc interstitial (Zni) and zinc anti-site (ZnO) are decreasing, while it increases for zinc vacancy (VZn), oxygen interstitial (Oi) and oxygen anti-site (OZn). They are more sensitive to temperature than oxygen partial pressure. There are two interesting phenomena. First, VO or VZn have the lowest formation energies for whole Fermi level at special environment condition (such as at T = 300K, about PO2 = 10-10atm or T = 1500K, about PO2 = 104atm) and intrinsic p-type doping of ZnO is possible by VZn at these special conditions. Second, VO as donors have lowest formation energy for all Fermi level at high temperature and low oxygen partial pressure (T = 1500K, PO2 = 10-10atm). According to our analysis, the VO could produce n-type doping in ZnO at these special conditions and change p-type ZnO to n-type ZnO at condition from low temperature and high oxygen partial pressure to high temperature and low oxygen partial pressure.
1990-04-01
selected for this study because of the availability of MSD crackgrowth data pertinent to the type of situation for which the proof test had been proposed...proof and maximum service pressures. A range of proof pressure was studied , not only for the effect on post-test safe crack growth interval, but also...to investigate the potential for stable crack extension during the test itself. 30 The study author recommended 1.5P as the optimum proof pressure, the
Implantable blood pressure sensor for analyzing elasticity in arteries
NASA Astrophysics Data System (ADS)
Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.
2009-03-01
MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.
NASA Technical Reports Server (NTRS)
Miller, Eric L.; Dudenhoefer, James E.
1989-01-01
In free piston Stirling engine research the integrity of both amplitude and phase of the dynamic pressure measurements is critical to the characterization of cycle dynamics and thermodynamics. It is therefore necessary to appreciate all possible sources of signal distortion when designing pressure measurement systems for this type of research. The signal distortion inherent to pressure transmission lines is discussed. Based on results from classical analysis, guidelines are formulated to describe the dynamic response properties of a volume-terminated transmission tube for applications involving helium-charged free piston Stirling engines. The scope and limitations of the dynamic response analysis are considered.
Optical detection system for MEMS-type pressure sensor
NASA Astrophysics Data System (ADS)
Sareło, K.; Górecka-Drzazga, A.; Dziuban, J. A.
2015-07-01
In this paper a special optical detection system designed for a MEMS-type (micro-electro-mechanical system) silicon pressure sensor is presented. The main part of the optical system—a detection unit with a perforated membrane—is bonded to the silicon sensor, and placed in a measuring system. An external light source illuminates the membrane of the pressure sensor. Owing to the light reflected from the deflected membrane sensor, the optical pattern consisting of light points is visible, and pressure can be estimated. The optical detection unit (20 × 20 × 20.4 mm3) is fabricated using microengineering techniques. Its dimensions are adjusted to the dimensions of the pressure sensor (5 × 5 mm2 silicon membrane). Preliminary tests of the optical detection unit integrated with the silicon pressure sensor are carried out. For the membrane sensor from 15 to 60 µm thick, a repeatable detection of the differential pressure in the range of 0 to 280 kPa is achieved. The presented optical microsystem is especially suitable for the pressure measurements in a high radiation environment.
Crystal structure of solid molecular hydrogen under high pressures
NASA Astrophysics Data System (ADS)
Cui, T.; Ma, Y.; Zou, G.
2002-11-01
In an effort to achieve a comprehensive understanding of the structure of dense H2, we have performed path-integral Monte Carlo simulations for three combinations of pressures and temperatures corresponding to three phases of solid hydrogen. Our results suggest three kinds of distribution of molecules: orientationally disordered hexagonal close packed (hcp), orientationally ordered hcp with Pa3-type local orientation order and orientationally ordered orthorhombic structure of Cmca symmetry, for the three phases.
Modification of a liquid hydrogen tank for integrated refrigeration and storage
NASA Astrophysics Data System (ADS)
Swanger, A. M.; Jumper, K. M.; Fesmire, J. E.; Notardonato, W. U.
2015-12-01
The modification and outfitting of a 125,000-liter liquid hydrogen tank was performed to provide integrated refrigeration and storage capability. These functions include zero boil-off, liquefaction, and densification and therefore require provisions for sub-atmospheric tank pressures within the vacuum-jacketed, multilayer insulated tank. The primary structural modification was to add stiffening rings inside the inner vessel. The internal stiffening rings were designed, built, and installed per the ASME Boiler and Pressure Vessel Code, Section VIII, to prevent collapse in the case of vacuum jacket failure in combination with sub-atmospheric pressure within the tank. For the integrated refrigeration loop, a modular, skeleton-type heat exchanger, with refrigerant temperature instrumentation, was constructed using the stiffening rings as supports. To support the system thermal performance testing, three custom temperature rakes were designed and installed along the 21-meter length of the tank, once again using rings as supports. The temperature rakes included a total of 20 silicon diode temperature sensors mounted both vertically and radially to map the bulk liquid temperature within the tank. The tank modifications were successful and the system is now operational for the research and development of integrated refrigeration technology.
Characteristics of exploding metal wires in water with three discharge types
NASA Astrophysics Data System (ADS)
Han, Ruoyu; Wu, Jiawei; Zhou, Haibin; Ding, Weidong; Qiu, Aici; Clayson, Thomas; Wang, Yanan; Ren, Hang
2017-07-01
This paper presents the characteristics of underwater electrical wire explosion (UEWE) with three discharge types, namely, Type-A, Type-B, and Type-C. Experiments were carried out with copper and tungsten wires (4 cm long and 50-300 μm in diameter) driven by a microsecond time-scale pulsed current source with 500 J stored energy. A time-integrated spectrometer and a photodiode were used to measure the optical emission of UEWE. A Polyvinylidene Fluoride probe was adopted to record the pressure waveforms. Experimental results indicate that from Type-A to Type-C, more energy deposits prior to the voltage peak and the first peak power increases drastically. This variation of energy deposition influences the optical emission and shock wave generation process. Specifically, the light intensity decreases by more than 90% and the peak of continuous spectra moves from ˜400 nm to ˜700 nm. In addition, the peak pressure of the first shock wave increases from ˜2 MPa to more than 7.5 MPa.
Navy Nuclear-Powered Surface Ships: Background, Issues, and Options for Congress
2010-09-29
to design a smaller scale version of a naval pressurized water reactor , or to design a new reactor type potentially using a thorium liquid salt...integrated nuclear power system capable of use on destroyer- sized vessels either using a pressurized water reactor or a thorium liquid salt reactor ...nuclear reactors for Navy surface ships. The text of Section 246 is as follows: SEC. 246. STUDY ON THORIUM -LIQUID FUELED REACTORS FOR NAVAL FORCES
Fluidic origami with embedded pressure dependent multi-stability: a plant inspired innovation
Li, Suyi; Wang, K. W.
2015-01-01
Inspired by the impulsive movements in plants, this research investigates the physics of a novel fluidic origami concept for its pressure-dependent multi-stability. In this innovation, fluid-filled tubular cells are synthesized by integrating different Miura-Ori sheets into a three-dimensional topological system, where the internal pressures are strategically controlled similar to the motor cells in plants. Fluidic origami incorporates two crucial physiological features observed in nature: one is distributed, pressurized cellular organization, and the other is embedded multi-stability. For a single fluidic origami cell, two stable folding configurations can coexist due to the nonlinear relationships among folding, crease material deformation and internal volume change. When multiple origami cells are integrated, additional multi-stability characteristics could occur via the interactions between pressurized cells. Changes in the fluid pressure can tailor the existence and shapes of these stable folding configurations. As a result, fluidic origami can switch between being mono-stable, bistable and multi-stable with pressure control, and provide a rapid ‘snap-through’ type of shape change based on the similar principles as in plants. The outcomes of this research could lead to the development of new adaptive materials or structures, and provide insights for future plant physiology studies at the cellular level. PMID:26400197
Fluidic origami with embedded pressure dependent multi-stability: a plant inspired innovation.
Li, Suyi; Wang, K W
2015-10-06
Inspired by the impulsive movements in plants, this research investigates the physics of a novel fluidic origami concept for its pressure-dependent multi-stability. In this innovation, fluid-filled tubular cells are synthesized by integrating different Miura-Ori sheets into a three-dimensional topological system, where the internal pressures are strategically controlled similar to the motor cells in plants. Fluidic origami incorporates two crucial physiological features observed in nature: one is distributed, pressurized cellular organization, and the other is embedded multi-stability. For a single fluidic origami cell, two stable folding configurations can coexist due to the nonlinear relationships among folding, crease material deformation and internal volume change. When multiple origami cells are integrated, additional multi-stability characteristics could occur via the interactions between pressurized cells. Changes in the fluid pressure can tailor the existence and shapes of these stable folding configurations. As a result, fluidic origami can switch between being mono-stable, bistable and multi-stable with pressure control, and provide a rapid 'snap-through' type of shape change based on the similar principles as in plants. The outcomes of this research could lead to the development of new adaptive materials or structures, and provide insights for future plant physiology studies at the cellular level. © 2015 The Author(s).
Therapeutic Outcome of Achalasia Based on High-Resolution Manometry: A Korean Multicenter Study.
Lee, Hyuk; Chung, Hyunsoo; Lee, Tae Hee; Hong, Kyoung Sup; Youn, Young Hoon; Park, Jung Ho; Park, Hyung Seok; Park, Hyojin
2017-09-11
Because achalasia subtype is associated with therapeutic response, it is possible that regional differences in subtype distribution could lead to differences in therapeutic outcomes. We aimed to evaluate and compare high-resolution manometry (HRM) profiles among the different subtypes of achalasia and to elucidate predictive factors associated with treatment outcomes. Patients who were diagnosed with achalasia using HRM at 4 Korean university hospitals were retrospectively identified and analyzed. Sixty-four patients with untreated achalasia were divided into 3 subtypes using the Chicago classification system. Clinical characteristics, manometric features, and treatment outcomes were compared. Among 64 patients diagnosed with achalasia, 31 patients were classified as type I, 27 as type II, and 6 as type III. Regarding HRM parameters, there were statistically significant differences in basal lower esophageal sphincter pressure, 4-second-integrated relaxation pressure, residual upper esophageal sphincter pressure, body amplitude, and maximal intrabolus pressure between subtypes. Regarding therapeutic outcome, type II patients (overall success rate of 80.0%) were more likely to respond than type I (55.2%) or type III (33.2%) patients. Multivariate analysis demonstrated that achalasia subtype (type I vs. III, P = 0.072; type II vs. III, P = 0.005), therapeutic modality (dilation vs. pharmacologic, P = 0.013; laparoscopic Heller's myotomy vs. pharmacologic, P = 0.006), and HRM-measured esophageal length (<27.5 vs. ≥27.5 cm, P = 0.014) are independent predictive factors for therapeutic failure. Patients with type II achalasia had better treatment outcomes than patients with other achalasia subtypes. Achalasia subtype, therapeutic modality, and esophageal length are independent predictive factors of therapeutic outcome.
Kim, Yong Doo; Kang, Ji Hwan; Bae, Hyun Kil; Kang, Namgoo; Oh, Sang Hyub; Lee, Jin-Hong; Woo, Jin Chun; Lee, Sangil
2017-11-21
Liquid hydrocarbon mixtures such as liquefied petroleum gas and liquefied natural gas are becoming integral parts of the world's energy system. Certified reference materials (CRMs) of liquid hydrocarbon mixtures are necessary to allow assessment of the accuracy and traceability of the compositions of such materials. A piston-type constant-pressure cylinder (PCPC) comprising chambers for a pressurizing gas (helium) and liquid (hydrocarbons) separated by a piston can be used to develop accurate and traceable liquid hydrocarbon mixture CRMs. The development of accurate CRMs relies on the maintenance of their composition. However, a PCPC might allow hydrocarbons to leak owing to the imperfect seal of the piston. In this study, a novel leak-free bellows-type constant-pressure cylinder (BCPC) is designed and evaluated by comparison with PCPCs. Liquid hydrocarbon mixtures consisting of ethane, propane, propene, isobutane, n-butane, 1-butene, and isopentane were prepared in both types of constant pressure cylinders and then monitored to check leakages between the gas and liquid chambers. Overall, notable leakage occurred from and into both chambers in the PCPCs, whereas no leakage occurred in the BCPCs in the three months after their gravimetric preparation. The BCPCs maintained no leakage even 10 months after their preparation, whereas the PCPCs showed significantly increasing leakage during the same period.
Risk factors correlated with plantar pressure in Chinese patients with type 2 diabetes.
Qiu, Xuan; Tian, De-Hu; Han, Chang-Ling; Chen, Wei; Wang, Zhan-Jian; Mu, Zhen-Yun; Li, Xu; Liu, Kuan-Zhi
2013-12-01
Plantar pressure is a key factor for predicting ulceration in the foot of a diabetes patient. We recruited a group of 100 Chinese patients with type 2 diabetes and an age-, sex-, weight-, and height-matched group of 100 Chinese subjects without diabetes. We obtained plantar pressure data using a Footscan(®) gait system (RsScan International, Olen, Belgium) when the subjects with and without diabetes walked barefoot across a sensor platform. We recorded the maximum force, maximum pressure, impulse, pressure-time integral, and loading rate from 10 regions of the foot. We collected the data of 11 history-based variables, 10 anthropometric variables, and three metabolic variables regarding the clinical characteristics of the diabetes patients. Weight was identified as a determining factor for high plantar pressure. Height, the Neuropathy Symptom Score (NSS), and ankle-brachial index (ABI) were correlated positively with plantar pressure measurements, respectively. The sex, history of ulcer and callus, intima-media membrane of the lower limb blood vessels, and fasting blood glucose (FBG) could also explain a portion of the variability of the plantar pressure measurements. However, the correlations were low or weak. High plantar pressure in diabetes patients could be predicted, in part, based on weight, height, NSS, ABI, sex, history of ulcer and callus, intima-media membrane of the lower limb blood vessels, and FBG. Therefore, interventions should be taken specifically before high plantar pressure emerges.
The LEAN Payload Integration Process
NASA Technical Reports Server (NTRS)
Jordan, Lee P.; Young, Yancy; Rice, Amanda
2011-01-01
It is recognized that payload development and integration with the International Space Station (ISS) can be complex. This streamlined integration approach is a first step toward simplifying payload integration; making it easier to fly payloads on ISS, thereby increasing feasibility and interest for more research and commercial organizations to sponsor ISS payloads and take advantage of the ISS as a National Laboratory asset. The streamlined integration approach was addressed from the perspective of highly likely initial payload types to evolve from the National Lab Pathfinder program. Payloads to be accommodated by the Expedite the Processing of Experiments for Space Station (EXPRESS) Racks and Microgravity Sciences Glovebox (MSG) pressurized facilities have been addressed. It is hoped that the streamlined principles applied to these types of payloads will be analyzed and implemented in the future for other host facilities as well as unpressurized payloads to be accommodated by the EXPRESS Logistics Carrier (ELC). Further, a payload does not have to be classified as a National Lab payload in order to be processed according to the lean payload integration process; any payload that meets certain criteria can follow the lean payload integration process.
NASA Astrophysics Data System (ADS)
Leng, Xuefei; Zhang, Jianhui; Jiang, Yan; Wang, Shouyin; Zhao, Chunsheng
2014-07-01
The current research of the valveless piezoelectric pump focuses on increasing the flow rate and pressure differential. Compared with the valve piezoelectric pump, the valveless one has excellent performances in simple structure, low cost, and easy miniaturization. So, their important development trend is the mitigation of their weakness, and the multi-function integration. The flow in a spiral tube element is sensitive to the element attitude caused by the Coriolis force, and that a valveless piezoelectric pump is designed by applying this phenomenon. The pump has gyroscopic effect, and has both the actuator function of fluid transfer and the sensor function, which can obtain the angular velocity when its attitude changes. First, the present paper analyzes the flow characteristics in the tube, obtains the calculation formula for the pump flow, and identifies the relationship between pump attitude and flow, which clarifies the impact of flow and driving voltage, frequency, spiral line type and element attitude, and verifies the gyroscopic effect of the pump. Then, the finite element simulation is used to verify the theory. Finally, a pump is fabricated for experimental testing of the relationship between pump attitude and pressure differential. Experimental results show that when Archimedes spiral θ=4π is selected for the tube design, and the rotation speed of the plate is 70 r/min, the pressure differential is 88.2 Pa, which is 1.5 times that of 0 r/min rotation speed. The spiral-tube-type valveless piezoelectric pump proposed can turn the element attitude into a form of pressure output, which is important for the multi-function integration of the valveless piezoelectric pump and for the development of civil gyroscope in the future.
Fabrication and characterization of bending and pressure sensors for a soft prosthetic hand
NASA Astrophysics Data System (ADS)
Rocha, Rui Pedro; Alhais Lopes, Pedro; de Almeida, Anibal T.; Tavakoli, Mahmoud; Majidi, Carmel
2018-03-01
We demonstrate fabrication, characterization, and implementation of ‘soft-matter’ pressure and bending sensors for a soft robotic hand. The elastomer-based sensors are embedded in a robot finger composed of a 3D printed endoskeleton and covered by an elastomeric skin. Two types of sensors are evaluated, resistive pressure sensors and capacitive pressure sensors. The sensor is fabricated entirely out of insulating and conductive rubber, the latter composed of polydimethylsiloxane (PDMS) elastomer embedded with a percolating network of structured carbon black (CB). The sensor-integrated fingers have a simple materials architecture, can be fabricated with standard rapid prototyping methods, and are inexpensive to produce. When incorporated into a robotic hand, the CB-PDMS sensors and PDMS carrier medium function as an ‘artificial skin’ for touch and bend detection. Results show improved response with a capacitive sensor architecture, which, unlike a resistive sensor, is robust to electromechanical hysteresis, creep, and drift in the CB-PDMS composite. The sensorized fingers are integrated in an anthropomorphic hand and results for a variety of grasping tasks are presented.
76 FR 53086 - Pipeline Safety: Safety of Gas Transmission Pipelines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-25
... and external corrosion (subpart I of 49 CFR part 192). Pressure tests of new pipelines (subpart J of..., integrate and validate data (e.g., review of mill inspection reports, hydrostatic tests reports, pipe leaks... chemical properties, mill inspection reports, hydrostatic tests reports, coating type and condition, pipe...
Comprehensive helicopter rotor instrumentation - A retrofit approach using miniature transducers
NASA Technical Reports Server (NTRS)
Jacklin, Stephen A.; Mort, Ray; Morrison, Dwayne
1992-01-01
This paper reports an approach used to retrofit a set of full-scale main rotor blades with 290 miniature pressure transducers, 46 strain gages, and 24 miniature accelerometers. Normally, in order to avoid disturbing the aerodynamics of the rotor flow field, the pressure instrumentation must be integrally built into the body of the rotor blades. However, using a method developed with NASA, miniature pressure transducers are mounted to the blade exterior surface without degrading the quality of the blade aerodynamics. Moreover, it is estimated that this approach reduced costs by more than 50 percent over building a set of pressure instrumented blades. The aerodynamic measurement objectives are presented as are instrumentation design considerations, type of instrumentation used, assembly process, and the installed instrumentation characteristics.
Anbarian, Mehrdad; Esmaeili, Hamed
2016-07-01
This study aimed to assess the effects of running-induced fatigue on plantar pressure parameters in novice runners with low and high medial longitudinal arch. Plantar pressure data from 42 novice runners (21 with high, and 21 with low arch) were collected before and after running-induced fatigue protocol during running at 3.3m/s along the Footscan(®) platform. Peak plantar pressure, peak force and force-time integral (impulse) were measured in ten anatomical zones. Relative time for foot roll-over phases and medio-lateral force ratio were calculated before and after the fatigue protocol. After the fatigue protocol, increases in the peak pressure under the first-third metatarsal zones and reduction under the fourth-fifth metatarsal regions were observed in the low arch individuals. In the high arch group, increases in peak pressure under the fourth-fifth metatarsal zones after the running-induced fatigue was observed. It could be concluded that running-induced fatigue had different effects on plantar pressure distribution pattern among novice runners with low and high medial longitudinal foot arch. These findings could provide some information related to several running injuries among individuals with different foot types. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of eccentricities and lateral pressure on the design of stiffened compression panels
NASA Technical Reports Server (NTRS)
Giles, G. L.; Anderson, M. S.
1972-01-01
An analysis for determining the effects of eccentricities and lateral pressure on the design of stiffened compression panels is presented. The four types of panel stiffeners considered are integral, zee, integral zee, and integral tee. Mass-strength curves, which give the mass of the panel necessary to carry a specified load, are given along with related design equations needed to calculate the cross-sectional dimensions of the minimum-mass-stiffened panel. The results of the study indicate that the proportions of the panels are geometrically similar to the proportions of panels designed for no eccentricity or lateral pressure, but no cross-sectional dimensions are greater, resulting in significantly increased mass. The analytical minimum-mass designs of zee-stiffened panels are compared with designs from experimentally derived charts. An assumed eccentricity of 0.001 times the length of the panel is used to correlate the analytical and experimental data. Good correlation between the experimentally derived and the analytical curves is obtained for the range of loading where materials yield governs the design. At lower loads the mass given by the analytical curve using this assumed eccentricity is greater than that given by the experimental results.
A high-temperature high-pressure calorimeter for determining heats of solution up to 623 K.
Djamali, Essmaiil; Turner, Peter J; Murray, Richard C; Cobble, James W
2010-07-01
A high-temperature high-pressure isoperibol calorimeter for determining the heats of solution and reaction of very dilute substances in water (10(-4) m) at temperatures up to 623 K is described. The energies of vaporization of water at steam saturation pressure were measured as a function of temperature and the results agree with the corresponding values from steam tables to better than 0.08+/-0.18%. The novelties of the present instrument relative to flow type heat capacity calorimeters are that measurements can be made at orders of magnitude lower concentrations and that measurement of heat of reaction involving solids or gases or in the presence of high concentrations of supporting electrolytes, acids, and bases is possible. Furthermore, the advantage of using enthalpy data over heat capacity data for calculations of the standard state Gibbs free energies of electrolytes is that the experimental heat data of this research need only be integrated once to derive higher temperature free energy data from lower temperatures. The derived heat capacities can be used mathematically to obtain free energies by double integration. However, the resulting errors are much smaller than if experimental aqueous heat capacities were used for the integrations.
Drug Discovery and Development of Type 2 Diabetes Mellitus: Modern-Integrative Medicinal Approach.
Ghosh, Debosree; Parida, Pratap
2016-01-01
Type 2 diabetes is a disorder of ages, which has become deadlier because of life style modification and adaptation in the modern world. Extensive sudy of the pathophysiology of diabetes has opened up various mysteries about the disease and has helped us to know and understand diabetes in a better manner. Presently, we know many minute details about the pathophysiology of diabetes mellitus and are thus well weaponed to fight against it. Treatment regime has been evolving daily. Besides the conventional anti-diabetic drugs, integrated medicinal approach for treating diabetes type 2 with a compact therapeutic approach consisting of various targeted treatments for individual symptoms associated with the disease are being tried currently. Diabetes associated complications like high blood pressure, hyperglycemia, microalbumuria, dyslipidemia, pro -coagulation, etc. are being targeted and dealt with individually in the integrative medicinal approach. The results are promising and thus ignite hope for a better and more successful handling of diabetes and diabetes related pathophysiological complications in near future.
Effect of ultrasonic cavitation on measurement of sound pressure using hydrophone
NASA Astrophysics Data System (ADS)
Thanh Nguyen, Tam; Asakura, Yoshiyuki; Okada, Nagaya; Koda, Shinobu; Yasuda, Keiji
2017-07-01
Effect of ultrasonic cavitation on sound pressure at the fundamental, second harmonic, and first ultraharmonic frequencies was investigated from low to high ultrasonic intensities. The driving frequencies were 22, 304, and 488 kHz. Sound pressure was measured using a needle-type hydrophone and ultrasonic cavitation was estimated from the broadband integrated pressure (BIP). With increasing square root of electric power applied to a transducer, the sound pressure at the fundamental frequency linearly increased initially, dropped at approximately the electric power of cavitation inception, and afterward increased again. The sound pressure at the second harmonic frequency was detected just below the electric power of cavitation inception. The first ultraharmonic component appeared at around the electric power of cavitation inception at 304 and 488 kHz. However, at 22 kHz, the first ultraharmonic component appeared at a higher electric power than that of cavitation inception.
Smart insole sensors for sports and rehabilitation
NASA Astrophysics Data System (ADS)
Tamm, Tarmo; Pärlin, Karel; Tiimus, Tõnis; Leemets, Kaur; Terasmaa, Tõnis; Must, Indrek
2014-04-01
A light-weight, soft, robust and low cost sensory system integrated into the inner soles of footwear is being developed that channels information to a mobile device, allowing to assess the ergonomics of the technique applied and to achieve improved performance in several fields of sport, to develop orthopedic footwear or monitor elevated plantar pressures for several fields of medicine, including early detection of diabetic foot ulceration. The advantages and disadvantages of several sensory material types were considered in the present work, focusing on signal reproducibility for periodic pressure measurements, response frequency and long-term stability, especially after extended load periods. Promising results were obtained for both capacitive and resistive sensory materials, utilizing virtually the same electronics platform for both types.
P05.05. A Multidisciplinary Approach to Hypertension: Yes We Can!
Cheng, Catherine; Burns, Virginia; Southard, Carol; Silberg, Aline; Crowley, Maggie; Feldman, Howard; Meyer, Mary Anne
2013-01-01
Focus Area: Integrative Approaches to Care Hypertension is one of the most common chronic diseases in our nation, affecting approximately 75 million adults, according to the American Heart Association. Data from the JNC-7 in 2003 demonstrated that about two-thirds of those individuals who are being treated with conventional antihypertensive agents did not have their blood pressure under control. Thus, there is a clear need for a complementary and integrative approach to fill in the gaps left by conventional medicine in the treatment of hypertension. In addition, many patients either cannot tolerate conventional antihypertensive medications or are more interested in trying other types of treatments to help control their blood pressure. There are myriad complementary and integrative approaches used for antihypertensive effects, and it is beneficial for practitioners to be aware of the available options. But beyond simply knowing about the choices they have to help their patients manage their hypertension, it is also important for providers to know what evidence exists for the different modalities in order to help direct their patients to make the best choices for their own overall health. The poster presentation will address segments on integrative treatment approaches for hypertension that will include (1) acupuncture and traditional Chinese medicine; (2) tobacco cessation; (3) massage therapy; (4) mindfulness meditation; (5) qi gong; and (6) overall lifestyle change—diet, exercise, and supplements. For most of the individual segments, there will be demonstrations of techniques to be done either with the group as a whole or with individual volunteers. The presenter will discuss the available research for each of the treatment modalities as well as the types of patients who might respond well to specific types of treatment.
Piek, J; Raes, P
1996-01-01
We described a new ventricular catheter that is the combination of a "classic" ventricular catheter with a piezo-resistive transducer at its tip. The device allows parallel recordings of intraventricular fluid pressure via a chip and a fluid-filled external transducer, drainage of cerebrospinal fluid from the ventricle or injection of fluid into the ventricle with simultaneous monitoring of intracranial pressure, and recording of brain tissue pressure in cases of misplacement or dislocation of the ventricular catheter or in cases of progressively narrowing ventricles caused by brain edema. Clinical tests in various situations at different pressure ranges (total recording time, 1356 h in 13 patients) gave excellent correlations of both pressures. Application of the device is especially indicated in clinical situations in which pressure-controlled drainage is desirable, occlusion of ventricular bolts is likely, or pressure-volume tests are needed.
On Small Disturbance Ascent Vent Behavior
NASA Technical Reports Server (NTRS)
Woronowicz, Michael
2015-01-01
As a spacecraft undergoes ascent in a launch vehicle, its ambient pressure environment transitions from one atmosphere to high vacuum in a matter of a few minutes. Venting of internal cavities is necessary to prevent the buildup of pressure differentials across cavity walls. These pressure differentials are often restricted to low levels to prevent violation of container integrity. Such vents usually consist of fixed orifices, ducts, or combinations of both. Duct conductance behavior is fundamentally different from that for orifices in pressure driven flows governing the launch vehicle ascent depressurization environment. Duct conductance is governed by the average pressure across its length, while orifice conductance is dictated by a pressure ratio. Hence, one cannot define a valid equivalent orifice for a given duct across a range of pressure levels. This presentation discusses development of expressions for these two types of vent elements in the limit of small pressure differentials, explores conditions for their validity, and compares their features regarding ascent depressurization performance.
Garain, Samiran; Jana, Santanu; Sinha, Tridib Kumar; Mandal, Dipankar
2016-02-01
We report an efficient, low-cost in situ poled fabrication strategy to construct a large area, highly sensitive, flexible pressure sensor by electrospun Ce(3+) doped PVDF/graphene composite nanofibers. The entire device fabrication process is scalable and enabling to large-area integration. It can able to detect imparting pressure as low as 2 Pa with high level of sensitivity. Furthermore, Ce(3+)-doped PVDF/graphene nanofiber based ultrasensitive pressure sensors can also be used as an effective nanogenerator as it generating an output voltage of 11 V with a current density ∼6 nA/cm(2) upon repetitive application of mechanical stress that could lit up 10 blue light emitting diodes (LEDs) instantaneously. Furthermore, to use it in environmental random vibrations (such as wind flow, water fall, transportation of vehicles, etc.), nanogenerator is integrated with musical vibration that exhibits to power up three blue LEDs instantly that promises as an ultrasensitive acoustic nanogenerator (ANG). The superior sensing properties in conjunction with mechanical flexibility, integrability, and robustness of nanofibers enabled real-time monitoring of sound waves as well as detection of different type of musical vibrations. Thus, ANG promises to use as an ultrasensitive pressure sensor, mechanical energy harvester, and effective power source for portable electronic and wearable devices.
NASA Astrophysics Data System (ADS)
Liu, Wentao; Liu, Zhanqiang
2018-03-01
Machinability improvement of titanium alloy Ti-6Al-4V is a challenging work in academic and industrial applications owing to its low thermal conductivity, low elasticity modulus and high chemical affinity at high temperatures. Surface integrity of titanium alloys Ti-6Al-4V is prominent in estimating the quality of machined components. The surface topography (surface defects and surface roughness) and the residual stress induced by machining Ti-6Al-4V occupy pivotal roles for the sustainability of Ti-6Al-4V components. High-pressure coolant (HPC) is a potential choice in meeting the requirements for the manufacture and application of Ti-6Al-4V. This paper reviews the progress towards the improvements of Ti-6Al4V surface integrity under HPC. Various researches of surface integrity characteristics have been reported. In particularly, surface roughness, surface defects, residual stress as well as work hardening are investigated in order to evaluate the machined surface qualities. Several coolant parameters (including coolant type, coolant pressure and the injection position) deserve investigating to provide the guidance for a satisfied machined surface. The review also provides a clear roadmap for applications of HPC in machining Ti-6Al4V. Experimental studies and analysis are reviewed to better understand the surface integrity under HPC machining process. A distinct discussion has been presented regarding the limitations and highlights of the prospective for machining Ti-6Al4V under HPC.
Conceptualizing and measuring integration: findings from the health systems integration study.
Gillies, R R; Shortell, S M; Anderson, D A; Mitchell, J B; Morgan, K L
1993-01-01
Given the pressures for health care reform, interest in the concept of integrated or organized delivery systems as a means to offer more coordinated cost-effective care is growing. This article has two primary objectives: (1) to clarify the different types of integration associated with the notion of an organized delivery system, and (2) to share the results from an ongoing study of 12 organized delivery systems. The findings indicate a moderate level of integration overall, particularly in the areas of culture, financial planning, and strategic planning. The study found that corporate staff respondents perceive their systems to be more integrated and effective than do operating unit managers, and that some functional integration areas are positively associated with both physician-system and clinical integration that, in turn, are positively related to each other. Overall, perceived integration was found to be positively associated with perceived effectiveness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiskoot, R.J.J.
Accurate and reliable sampling systems are imperative when confirming natural gas' commercial value. Buyers and sellers need accurate hydrocarbon-composition information to conduct fair sale transactions. Because of poor sample extraction, preparation or analysis can invalidate the sale, more attention should be directed toward improving representative sampling. Consider all sampling components, i.e., gas types, line pressure and temperature, equipment maintenance and service needs, etc. The paper discusses gas sampling, design considerations (location, probe type, extraction devices, controller, and receivers), operating requirements, and system integration.
Social integration, social contacts, and blood pressure dipping in African-Americans and whites.
Troxel, Wendy M; Buysse, Daniel J; Hall, Martica; Kamarck, Thomas W; Strollo, Patrick J; Owens, Jane F; Reis, Steven E; Matthews, Karen A
2010-02-01
Both the size and diversity of an individual's social network are strongly and prospectively linked with cardiovascular morbidity and mortality. Social relationships may influence cardiovascular outcomes, at least in part, via their impact on physiologic pathways influenced by stress, such as daytime blood pressure (BP) levels. However, scant research has examined whether social relationships influence key nocturnal pathways, such as nocturnal BP dipping. The current study examined the degree to which social integration, as measured by participants' reported engagement in a range of different types of social relationships, and the frequency of daily social contacts influence the ratio of night/day mean arterial pressure (MAP) in a community sample of African-American and white men and women (N = 224). In addition, we examined the degree to which observed associations persisted after statistical adjustment for factors known to covary with nocturnal BP, including objective measures of sleep, catecholamines, health behaviors, and comorbidities. In fully adjusted models, there was a significant association between both social integration and frequency of social contacts and the ratio of night/day MAP, indicating that socially isolated individuals were more likely to have blunted nocturnal BP-dipping profiles. There was also a significant interaction between social contact frequency and ethnicity, suggesting that the benefits of social relationships were particularly evident in African-Americans. These findings contribute to our understanding of how social integration or conversely, social isolation, influences cardiovascular risk.
Coupling Spatiotemporal Community Assembly Processes to Changes in Microbial Metabolism.
Graham, Emily B; Crump, Alex R; Resch, Charles T; Fansler, Sarah; Arntzen, Evan; Kennedy, David W; Fredrickson, Jim K; Stegen, James C
2016-01-01
Community assembly processes generate shifts in species abundances that influence ecosystem cycling of carbon and nutrients, yet our understanding of assembly remains largely separate from ecosystem-level functioning. Here, we investigate relationships between assembly and changes in microbial metabolism across space and time in hyporheic microbial communities. We pair sampling of two habitat types (i.e., attached and planktonic) through seasonal and sub-hourly hydrologic fluctuation with null modeling and temporally explicit multivariate statistics. We demonstrate that multiple selective pressures-imposed by sediment and porewater physicochemistry-integrate to generate changes in microbial community composition at distinct timescales among habitat types. These changes in composition are reflective of contrasting associations of Betaproteobacteria and Thaumarchaeota with ecological selection and with seasonal changes in microbial metabolism. We present a conceptual model based on our results in which metabolism increases when oscillating selective pressures oppose temporally stable selective pressures. Our conceptual model is pertinent to both macrobial and microbial systems experiencing multiple selective pressures and presents an avenue for assimilating community assembly processes into predictions of ecosystem-level functioning.
Performance of Several Combustion Chambers Designed for Aircraft Oil Engines
NASA Technical Reports Server (NTRS)
Joachim, William F; Kemper, Carlton
1928-01-01
Several investigations have been made on single-cylinder test engines to determine the performance characteristics of four types of combustion chambers designed for aircraft oil engines. Two of the combustion chambers studied were bulb-type precombustion chambers, the connecting orifice of one having been designed to produce high turbulence by tangential air flow in both the precombustion chamber and the cylinder. The other two were integral combustion chambers, one being dome-shaped and the other pent-roof shaped. The injection systems used included cam and eccentric driven fuel pumps, and diaphragm and spring-loaded fuel-injection valves. A diaphragm type maximum cylinder pressure indicator was used in part of these investigations with which the cylinder pressures were controlled to definite valves. The performance of the engines when equipped with each of the combustion chambers is discussed. The best performance for the tests reported was obtained with a bulb-type combustion chamber designed to give a high degree of turbulence within the bulb and cylinder. (author)
Scales, Jeffrey A; Butler, Marguerite A
2016-01-01
Despite the complexity of nature, most comparative studies of phenotypic evolution consider selective pressures in isolation. When competing pressures operate on the same system, it is commonly expected that trade-offs will occur that will limit the evolution of phenotypic diversity, however, it is possible that interactions among selective pressures may promote diversity instead. We explored the evolution of locomotor performance in lizards in relation to possible selective pressures using the Ornstein-Uhlenbeck process. Here, we show that a combination of selection based on foraging mode and predator escape is required to explain variation in performance phenotypes. Surprisingly, habitat use contributed little explanatory power. We find that it is possible to evolve very different abilities in performance which were previously thought to be tightly correlated, supporting a growing literature that explores the many-to-one mapping of morphological design. Although we generally find the expected trade-off between maximal exertion and speed, this relationship surprisingly disappears when species experience selection for both performance types. We conclude that functional integration need not limit adaptive potential, and that an integrative approach considering multiple major influences on a phenotype allows a more complete understanding of adaptation and the evolution of diversity. © 2015 The Author(s). Evolution © 2015 The Society for the Study of Evolution.
NASA Astrophysics Data System (ADS)
Johnston, Patrick H.; Parker, F. Raymond
2014-02-01
As an approach to light-weight, cost-effective and manufacturable structures required to enable the hybrid wing body aircraft, The Boeing Company, Inc. and NASA have developed the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. A PRSEUS pressure cube was developed as a risk reduction test article to examine a new integral cap joint concept as part of a building block approach for technology development of the PRSEUS concept. The overall specimen strength exceeded the 18.4 psi load requirement as testing resulted in the cube reaching a final pressure load of around 48 psi prior to catastrophic failure. The cube pressure test verified that the joints and structure were capable of sustaining the required loads, and represented the first testing of joined PRSEUS structure. This paper will address the damage arrestment performance of the stitched PRSEUS structure. Following catastrophic failure of the cube, ultrasonic pulse-echo inspection found that the localized damage, surrounding a barely-visible impact damage site, did not change noticeably between just after impact and catastrophic failure of the cube, and did not play a role in the catastrophic failure event. Ultrasonic inspection of the remaining intact cube panels presented three basic types of indications: delaminations between laminae parallel to the face sheets, lying between face sheet and tear strap layers, or between tear strap and flange layers; delaminations above the noodles of stringers, frames or integral caps, lying within face sheet or tear strap layers; and delaminations between the laminae in the inner fillets of the integral caps, where pulloff stresses were expected to be highest. Delaminations of all three types were predominantly contained by the first row of stitches encountered. For the small fraction of delaminations extending beyond the first row of stitches, all were contained by the second stitch row.
NASA Technical Reports Server (NTRS)
Johnston, Patrick H.; Parker, F. Raymond
2013-01-01
As an approach to light-weight, cost-effective and manufacturable structures required to enable the hybrid wing body aircraft, The Boeing Company, Inc. and NASA have developed the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. A PRSEUS pressure cube was developed as a risk reduction test article to examine a new integral cap joint concept as part of a building block approach for technology development of the PRSEUS concept. The overall specimen strength exceeded the 18.4 psi load requirement as testing resulted in the cube reaching a final pressure load of around 48 psi prior to catastrophic failure. The cube pressure test verified that the joints and structure were capable of sustaining the required loads, and represented the first testing of joined PRSEUS structure. This paper will address the damage arrestment performance of the stitched PRSEUS structure. Following catastrophic failure of the cube, ultrasonic pulse-echo inspection found that the localized damage, surrounding a barely-visible impact damage site, did not change noticeably between just after impact and catastrophic failure of the cube, and did not play a role in the catastrophic failure event. Ultrasonic inspection of the remaining intact cube panels presented three basic types of indications: delaminations between laminae parallel to the face sheets, lying between face sheet and tear strap layers, or between tear strap and flange layers; delaminations above the noodles of stringers, frames or integral caps, lying within face sheet or tear strap layers; and delaminations between the laminae in the inner fillets of the integral caps, where pulloff stresses were expected to be highest. Delaminations of all three types were predominantly contained by the first row of stitches encountered. For the small fraction of delaminations extending beyond the first row of stitches, all were contained by the second stitch row.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hussain, S. S.; Murtaza, Ghulam; Zakaullah, M.
Correlation of neutron emission with pinch energy for a Mather-type plasma focus energized by a single capacitor 12.5 muF, 21 kV (2.7 kJ) is investigated by employing time resolved and time integrated detectors for two different anode shapes. The maximum average neutron yield of about 1.3x10{sup 8} per shot is recorded with cylindrical anode, that increases to 1.6x10{sup 8} per shot for tapered anode. At optimum pressure the input energy converted to pinch energy is about 24% for cylindrical anode as compared to 36% for tapered anode. It is found that the tapered anode enhances neutron flux about 25+-5% bothmore » in axial and radial directions and also broadens the pressure range for neutron emission as well as pinch energy. The neutron yield and optimum gas filling pressures are found strongly dependent on the anode shape.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prins, A. D.; Lewis, M. K.; Bushell, Z. L.
2015-04-27
We report pressure-dependent photoluminescence (PL) experiments under hydrostatic pressures up to 2.16 GPa on a mid-wave infrared InAs/InAs{sub 0.86}Sb{sub 0.14} type-II superlattice (T2SL) structure at different pump laser excitation powers and sample temperatures. The pressure coefficient of the T2SL transition was found to be 93 ± 2 meV·GPa{sup −1}. The integrated PL intensity increases with pressure up to 1.9 GPa then quenches rapidly indicating a pressure induced level crossing with the conduction band states at ∼2 GPa. Analysis of the PL intensity as a function of excitation power at 0, 0.42, 1.87, and 2.16 GPa shows a clear change in the dominant photo-generated carrier recombination mechanism frommore » radiative to defect related. From these data, evidence for a defect level situated at 0.18 ± 0.01 eV above the conduction band edge of InAs at ambient pressure is presented. This assumes a pressure-dependent energy shift of −11 meV·GPa{sup −1} for the valence band edge and that the defect level is insensitive to pressure, both of which are supported by an Arrhenius activation energy analysis.« less
Blais, P; Patel, A; Sayuk, G S; Gyawali, C P
2017-12-01
The upper esophageal sphincter (UES) reflexively responds to bolus presence within the esophageal lumen, therefore UES metrics can vary in achalasia. Within consecutive patients undergoing esophageal high-resolution manometry (HRM), 302 patients (58.2±1.0 year, 57% F) with esophageal outflow obstruction were identified, and compared to 16 asymptomatic controls (27.7±0.7 year, 56% F). Esophageal outflow obstruction was segregated into achalasia subtypes 1, 2, and 3, and esophagogastric junction outflow obstruction (EGJOO with intact peristalsis) using Chicago Classification v3.0. UES and lower esophageal sphincter (LES) metrics were compared between esophageal outflow obstruction and normal controls using univariate and multivariate analysis. Linear regression excluded multicollinearity of pressure metrics that demonstrated significant differences across individual subtype comparisons. LES integrated relaxation pressure (IRP) had utility in differentiating achalasia from controls (P<.0001), but no utility in segregating between subtypes (P=.27). In comparison to controls, patients collectively demonstrated univariate differences in UES mean basal pressure, relaxation time to nadir, recovery time, and residual pressure (UES-RP) (P≤.049). UES-RP was highest in type 2 achalasia (P<.0001 compared to other subtypes and controls). In multivariate analysis, only UES-RP retained significance in comparison between each of the subgroups (P≤.02 for each comparison). Intrabolus pressure was highest in type 3 achalasia; this demonstrated significant differences across some but not all subtype comparisons. Nadir UES-RP can differentiate achalasia subtypes within the esophageal outflow obstruction spectrum, with highest values in type 2 achalasia. This metric likely represents a surrogate marker for esophageal pressurization. © 2017 John Wiley & Sons Ltd.
Opening of an interface flaw in a layered elastic half-plane under compressive loading
NASA Technical Reports Server (NTRS)
Kennedy, J. M.; Fichter, W. B.; Goree, J. G.
1984-01-01
A static analysis is given of the problem of an elastic layer perfectly bonded, except for a frictionless interface crack, to a dissimilar elastic half-plane. The free surface of the layer is loaded by a finite pressure distribution directly over the crack. The problem is formulated using the two dimensional linear elasticity equations. Using Fourier transforms, the governing equations are converted to a pair of coupled singular integral equations. The integral equations are reduced to a set of simultaneous algebraic equations by expanding the unknown functions in a series of Jacobi polynomials and then evaluating the singular Cauchy-type integrals. The resulting equations are found to be ill-conditioned and, consequently, are solved in the least-squares sense. Results from the analysis show that, under a normal pressure distribution on the free surface of the layer and depending on the combination of geometric and material parameters, the ends of the crack can open. The resulting stresses at the crack-tips are singular, implying that crack growth is possible. The extent of the opening and the crack-top stress intensity factors depend on the width of the pressure distribution zone, the layer thickness, and the relative material properties of the layer and half-plane.
Begolo, Stefano; Zhukov, Dmitriy V; Selck, David A; Li, Liang; Ismagilov, Rustem F
2014-12-21
Equipment-free pumping is a challenging problem and an active area of research in microfluidics, with applications for both laboratory and limited-resource settings. This paper describes the pumping lid method, a strategy to achieve equipment-free pumping by controlled generation of pressure. Pressure was generated using portable, lightweight, and disposable parts that can be integrated with existing microfluidic devices to simplify workflow and eliminate the need for pumping equipment. The development of this method was enabled by multi-material 3D printing, which allows fast prototyping, including composite parts that combine materials with different mechanical properties (e.g. both rigid and elastic materials in the same part). The first type of pumping lid we describe was used to produce predictable positive or negative pressures via controlled compression or expansion of gases. A model was developed to describe the pressures and flow rates generated with this approach and it was validated experimentally. Pressures were pre-programmed by the geometry of the parts and could be tuned further even while the experiment was in progress. Using multiple lids or a composite lid with different inlets enabled several solutions to be pumped independently in a single device. The second type of pumping lid, which relied on vapor-liquid equilibrium to generate pressure, was designed, modeled, and experimentally characterized. The pumping lid method was validated by controlling flow in different types of microfluidic applications, including the production of droplets, control of laminar flow profiles, and loading of SlipChip devices. We believe that applying the pumping lid methodology to existing microfluidic devices will enhance their use as portable diagnostic tools in limited resource settings as well as accelerate adoption of microfluidics in laboratories.
A comparison of cleat types during two football-specific tasks on FieldTurf.
Queen, R M; Charnock, B L; Garrett, W E; Hardaker, W M; Sims, E L; Moorman, C T
2008-04-01
To examine the effect of different cleat plate configurations on plantar pressure during two tasks. Thirty-six athletes ran an agility course 5 times while wearing 4 different types of Nike Vitoria cleats: (1) bladed, (2) elliptical firm ground, (3) hard ground and (4) turf. Plantar pressure data were recorded during a side cut and a cross cut using Pedar-X insoles. Controlled laboratory study No history of lower extremity injury in the past 6 months, no previous foot or ankle surgery, not currently wearing foot orthotics and play a cleated sport at least twice a week. Total foot contact time, contact area, maximum force, peak pressure and the force-time integral (FTI) in the medial, middle and lateral regions of the forefoot were collected. A 1x4 ANOVA (alpha = 0.05) was performed on each dependent variable. A Bonferroni adjustment was conducted (alpha = 0.008). In the cross cut task, statistical differences between cleats were observed in three variables: total foot peak pressure, lateral forefoot FTI, and lateral forefoot normalised maximum force. In the side cut task, statistical differences between cleats were observed in 4 variables: total foot peak pressure, the medial and middle forefoot FTI, and the medial and middle forefoot normalised maximum force. Significant differences in forefoot loading patterns existed between cleat types. Based on the results of this study, it might be beneficial to increase the forefoot cushioning in cleats in an attempt to decrease loading in these regions of the foot.
Conceptual Design of a 100kW Energy Integrated Type Bi-Directional Tidal Current Turbine
NASA Astrophysics Data System (ADS)
Kim, Ki Pyoung; Ahmed, M. Rafiuddin; Lee, Young Ho
2010-06-01
The development of a tidal current turbine that can extract maximum energy from the tidal current will be extremely beneficial for supplying continuous electric power. The present paper presents a conceptual design of a 100kW energy integrated type tidal current turbine for tidal power generation. The instantaneous power density of a flowing fluid incident on an underwater turbine is proportional to the cubic power of current velocity which is approximately 2.5m/s. A cross-flow turbine, provided with a nozzle and a diffuser, is designed and analyzed. The potential advantages of ducted and diffuser-augmented turbines were taken into consideration in order to achieve higher output at a relatively low speed. This study looks at a cross-flow turbine system which is placed in an augmentation channel to generate electricity bi-directionally. The compatibility of this turbine system is verified using a commercial CFD code, ANSYSCFX. This paper presents the results of the numerical analysis in terms of pressure, streaklines, velocity vectors and performance curves for energy integrated type bi-directional tidal current turbine (BDT) with augmentation.
Pressure tracking control of vehicle ABS using piezo valve modulator
NASA Astrophysics Data System (ADS)
Jeon, Juncheol; Choi, Seung-Bok
2011-03-01
This paper presents a wheel slip control for the ABS(anti-lock brake system) of a passenger vehicle using a controllable piezo valve modulator. The ABS is designed to optimize for braking effectiveness and good steerability. As a first step, the principal design parameters of the piezo valve and pressure modulator are appropriately determined by considering the braking pressure variation during the ABS operation. The proposed piezo valve consists of a flapper, pneumatic circuit and a piezostack actuator. In order to get wide control range of the pressure, the pressure modulator is desired. The modulator consists of a dual-type cylinder filled with different substances (fluid and gas) and a piston rod moving vertical axis to transmit the force. Subsequently, a quarter car wheel slip model is formulated and integrated with the governing equation of the piezo valve modulator. A sliding mode controller to achieve the desired slip rate is then designed and implemented. Braking control performances such as brake pressure and slip rate are evaluated via computer simulations.
Horses for courses: analytical tools to explore planetary boundaries
NASA Astrophysics Data System (ADS)
van Vuuren, Detlef P.; Lucas, Paul L.; Häyhä, Tiina; Cornell, Sarah E.; Stafford-Smith, Mark
2016-03-01
There is a need for more integrated research on sustainable development and global environmental change. In this paper, we focus on the planetary boundaries framework to provide a systematic categorization of key research questions in relation to avoiding severe global environmental degradation. The four categories of key questions are those that relate to (1) the underlying processes and selection of key indicators for planetary boundaries, (2) understanding the impacts of environmental pressure and connections between different types of impacts, (3) better understanding of different response strategies to avoid further degradation, and (4) the available instruments to implement such strategies. Clearly, different categories of scientific disciplines and associated model types exist that can accommodate answering these questions. We identify the strength and weaknesses of different research areas in relation to the question categories, focusing specifically on different types of models. We discuss that more interdisciplinary research is need to increase our understanding by better linking human drivers and social and biophysical impacts. This requires better collaboration between relevant disciplines (associated with the model types), either by exchanging information or by fully linking or integrating them. As fully integrated models can become too complex, the appropriate type of model (the racehorse) should be applied for answering the target research question (the race course).
Hertroijs, Dorijn F L; Elissen, Arianne M J; Brouwers, Martijn C G J; Schaper, Nicolaas C; Ruwaard, Dirk
2018-02-06
Aim To identify which patient-related effect modifiers influence the outcomes of integrated care programs for type 2 diabetes in primary care. Integrated care is a widespread management strategy for the treatment of type 2 diabetes. However, most integrated care programs are not tailored to patients' needs, preferences and abilities. There is increasing consensus that such a patient-centered approach could improve the management of type 2 diabetes. Thus far, it remains unclear which patient-related effect modifiers should guide such an approach. PubMed, CINAHL and EMBASE were searched for empirical studies published after 1998. A systematic literature review was conducted according to the PRISMA guidelines. Findings In total, 23 out of 1015 studies were included. A total of 21 studies measured the effects of integrated diabetes care programs on hemoglobin A1c (HbA1c) and three on low-density lipoprotein cholesterol, systolic blood pressure and health-care utilization. In total, 49 patient characteristics were assessed as potential effect modifiers with HbA1c as an outcome, of which 46 were person or health-related and only three were context-related. Younger age, insulin therapy and longer disease duration were associated with higher HbA1c levels in cross-sectional and longitudinal studies. Higher baseline HbA1c was associated with higher HbA1c at follow-up in longitudinal studies. Information on context- and person-related characteristics was limited, but is necessary to help identify the care needs of individual patients and implement an effective integrated type 2 diabetes tailored care program.
NASA Astrophysics Data System (ADS)
Sokolov, Leonid V.
2010-08-01
There is a need of measuring distributed pressure on the aircraft engine inlet with high precision within a wide operating temperature range in the severe environment to improve the efficiency of aircraft engine control. The basic solutions and principles of designing high-temperature (to 523K) microelectromechanical pressure sensors based on a membrane-type SOI heterostructure with a monolithic integral tensoframe (MEMS-SOIMT) are proposed in accordance with the developed concept, which excludes the use of electric p-n junctions in semiconductor microelectromechanical sensors. The MEMS-SOIMT technology relies on the group processes of microelectronics and micromechanics for high-precision microprofiling of a three-dimension micromechanical structure, which exclude high-temperature silicon doping processes.
Validation of CFD Codes for Parawing Geometries in Subsonic to Supersonic Flows
NASA Technical Reports Server (NTRS)
Cruz-Ayoroa, Juan G.; Garcia, Joseph A.; Melton, John E.
2014-01-01
Computational Fluid Dynamic studies of a rigid parawing at Mach numbers from 0.8 to 4.65 were carried out using three established inviscid, viscous and independent panel method codes. Pressure distributions along four chordwise sections of the wing were compared to experimental wind tunnel data gathered from NASA technical reports. Results show good prediction of the overall trends and magnitudes of the pressure distributions for the inviscid and viscous solvers. Pressure results for the panel method code diverge from test data at large angles of attack due to shock interaction phenomena. Trends in the flow behavior and their effect on the integrated force and moments on this type of wing are examined in detail using the inviscid CFD code results.
The effect of nitric oxide releasing cream on healing pressure ulcers
Saidkhani, Vahid; Asadizaker, Marziyeh; Khodayar, Mohammad Javad; Latifi, Sayed Mahmoud
2016-01-01
Background: Pressure ulcer is one of the main concerns of nurses in medical centers around the world, which, if untreated, causes irreparable problems for patients. In recent years, nitric oxide (NO) has been proposed as an effective method for wound healing. This study was conducted to determine the effect of nitric oxide on pressure ulcer healing. Materials and Methods: In this clinical trial, 58 patients with pressure ulcer at hospitals affiliated to Ahvaz Jundishapur University of Medical Sciences were homogenized and later divided randomly into two groups of treatment (nitric oxide cream; n = 29) and control (placebo cream; n = 29). In this research, the data collection tool was the Pressure Ulcer Scale for Healing (PUSH). At the outset of the study (before using the cream), the patients' ulcers were examined weekly in terms of size, amount of exudates, and tissue type using the PUSH tool for 3 weeks. By integrating these three factors, wound healing was determined. Data were analyzed using SPSS. Results: Although no significant difference was found in terms of the mean of score size, the amount of exudates, and the tissue type between the two groups, the mean of total score (healing) between the two groups was statistically significant (P = 0.04). Conclusions: Nitric oxide cream seems to accelerate wound healing. Therefore, considering its easy availability and cost-effectiveness, it can be used for treating pressure ulcers in the future. PMID:27186212
Design and evaluation of candidate pressure ports for the HYFLITE experiment
NASA Technical Reports Server (NTRS)
Teter, John E., Jr.; Cleckner, Craig S.; Vontheumer, Alfred E.
1994-01-01
A concept for placing a pressure transducer directly in a shuttle type tile was developed at Langley Research Center. A 5 inch long quartz with a .020 inch inner diameter provides the thermal isolation necessary to allow 2800 F surface pressure measurements to be taken by pressure transducer rated at 250 F. The assembly is potted in place with RTV 560 in a piece of FRCI-12 thermal protection system insulation tile. The integrity of the thermal protection system is maintained even with the intrusion of the pressure port assembly and the pressure port does not disrupt the air flow across the lifting body. Approximately 200 of these pressure ports are to be used in each of the Hypersonic Flight Experiment (HYFLITE) flight tests. Initial vibroacoustic and aerothermal testing of the pressure port designs have been completed at Langley Research vibration laboratory and the 20 MWatt 2 x 9 turbulent duct facility at Ames Research Center. The performance of the pressure ports were found to be well within the required design limits for all cases. In addition, a failure mode in which the entire pressure port assembly was removed proved to be a begin case.
Improved system integration for integrated gasification combined cycle (IGCC) systems.
Frey, H Christopher; Zhu, Yunhua
2006-03-01
Integrated gasification combined cycle (IGCC) systems are a promising technology for power generation. They include an air separation unit (ASU), a gasification system, and a gas turbine combined cycle power block, and feature competitive efficiency and lower emissions compared to conventional power generation technology. IGCC systems are not yet in widespread commercial use and opportunities remain to improve system feasibility via improved process integration. A process simulation model was developed for IGCC systems with alternative types of ASU and gas turbine integration. The model is applied to evaluate integration schemes involving nitrogen injection, air extraction, and combinations of both, as well as different ASU pressure levels. The optimal nitrogen injection only case in combination with an elevated pressure ASU had the highest efficiency and power output and approximately the lowest emissions per unit output of all cases considered, and thus is a recommended design option. The optimal combination of air extraction coupled with nitrogen injection had slightly worse efficiency, power output, and emissions than the optimal nitrogen injection only case. Air extraction alone typically produced lower efficiency, lower power output, and higher emissions than all other cases. The recommended nitrogen injection only case is estimated to provide annualized cost savings compared to a nonintegrated design. Process simulation modeling is shown to be a useful tool for evaluation and screening of technology options.
Integrating soft sensor systems using conductive thread
NASA Astrophysics Data System (ADS)
Teng, Lijun; Jeronimo, Karina; Wei, Tianqi; Nemitz, Markus P.; Lyu, Geng; Stokes, Adam A.
2018-05-01
We are part of a growing community of researchers who are developing a new class of soft machines. By using mechanically soft materials (MPa modulus) we can design systems which overcome the bulk-mechanical mismatches between soft biological systems and hard engineered components. To develop fully integrated soft machines—which include power, communications, and control sub-systems—the research community requires methods for interconnecting between soft and hard electronics. Sensors based upon eutectic gallium alloys in microfluidic channels can be used to measure normal and strain forces, but integrating these sensors into systems of heterogeneous Young’s modulus is difficult due the complexity of finding a material which is electrically conductive, mechanically flexible, and stable over prolonged periods of time. Many existing gallium-based liquid alloy sensors are not mechanically or electrically robust, and have poor stability over time. We present the design and fabrication of a high-resolution pressure-sensor soft system that can transduce normal force into a digital output. In this soft system, which is built on a monolithic silicone substrate, a galinstan-based microfluidic pressure sensor is integrated with a flexible printed circuit board. We used conductive thread as the interconnect and found that this method alleviates problems arising due to the mechanical mismatch between conventional metal wires and soft or liquid materials. Conductive thread is low-cost, it is readily wetted by the liquid metal, it produces little bending moment into the microfluidic channel, and it can be connected directly onto the copper bond-pads of the flexible printed circuit board. We built a bridge-system to provide stable readings from the galinstan pressure sensor. This system gives linear measurement results between 500-3500 Pa of applied pressure. We anticipate that integrated systems of this type will find utility in soft-robotic systems as used for wearable technologies like virtual reality, or in soft-medical devices such as exoskeletal rehabilitation robots.
FY16 Progress Report on Test Results In Support Of Integrated EPP and SMT Design Methods Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yanli; Jetter, Robert I.; Sham, T. -L.
2016-08-08
The proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology consists of incorporating an SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid using the creep-fatigue interaction diagram (the D diagram) and to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed code rules and to verify their applicability, a series of thermomechanical tests have been initiated. This report presents the recent test results for Type 2 SMT specimens on Alloy 617, Pressurization SMT on Alloy 617, Type 1 SMT on Gr. 91, and two-barmore » thermal ratcheting test results on Alloy 617 with a new thermal loading profile.« less
Shin, Sung-Ho; Ji, Sangyoon; Choi, Seiho; Pyo, Kyoung-Hee; Wan An, Byeong; Park, Jihun; Kim, Joohee; Kim, Ju-Young; Lee, Ki-Suk; Kwon, Soon-Yong; Heo, Jaeyeong; Park, Byong-Guk; Park, Jang-Ung
2017-03-31
Integrated electronic circuitries with pressure sensors have been extensively researched as a key component for emerging electronics applications such as electronic skins and health-monitoring devices. Although existing pressure sensors display high sensitivities, they can only be used for specific purposes due to the narrow range of detectable pressure (under tens of kPa) and the difficulty of forming highly integrated arrays. However, it is essential to develop tactile pressure sensors with a wide pressure range in order to use them for diverse application areas including medical diagnosis, robotics or automotive electronics. Here we report an unconventional approach for fabricating fully integrated active-matrix arrays of pressure-sensitive graphene transistors with air-dielectric layers simply formed by folding two opposing panels. Furthermore, this realizes a wide tactile pressure sensing range from 250 Pa to ∼3 MPa. Additionally, fabrication of pressure sensor arrays and transparent pressure sensors are demonstrated, suggesting their substantial promise as next-generation electronics.
NASA Astrophysics Data System (ADS)
Shin, Sung-Ho; Ji, Sangyoon; Choi, Seiho; Pyo, Kyoung-Hee; Wan An, Byeong; Park, Jihun; Kim, Joohee; Kim, Ju-Young; Lee, Ki-Suk; Kwon, Soon-Yong; Heo, Jaeyeong; Park, Byong-Guk; Park, Jang-Ung
2017-03-01
Integrated electronic circuitries with pressure sensors have been extensively researched as a key component for emerging electronics applications such as electronic skins and health-monitoring devices. Although existing pressure sensors display high sensitivities, they can only be used for specific purposes due to the narrow range of detectable pressure (under tens of kPa) and the difficulty of forming highly integrated arrays. However, it is essential to develop tactile pressure sensors with a wide pressure range in order to use them for diverse application areas including medical diagnosis, robotics or automotive electronics. Here we report an unconventional approach for fabricating fully integrated active-matrix arrays of pressure-sensitive graphene transistors with air-dielectric layers simply formed by folding two opposing panels. Furthermore, this realizes a wide tactile pressure sensing range from 250 Pa to ~3 MPa. Additionally, fabrication of pressure sensor arrays and transparent pressure sensors are demonstrated, suggesting their substantial promise as next-generation electronics.
Shin, Sung-Ho; Ji, Sangyoon; Choi, Seiho; Pyo, Kyoung-Hee; Wan An, Byeong; Park, Jihun; Kim, Joohee; Kim, Ju-Young; Lee, Ki-Suk; Kwon, Soon-Yong; Heo, Jaeyeong; Park, Byong-Guk; Park, Jang-Ung
2017-01-01
Integrated electronic circuitries with pressure sensors have been extensively researched as a key component for emerging electronics applications such as electronic skins and health-monitoring devices. Although existing pressure sensors display high sensitivities, they can only be used for specific purposes due to the narrow range of detectable pressure (under tens of kPa) and the difficulty of forming highly integrated arrays. However, it is essential to develop tactile pressure sensors with a wide pressure range in order to use them for diverse application areas including medical diagnosis, robotics or automotive electronics. Here we report an unconventional approach for fabricating fully integrated active-matrix arrays of pressure-sensitive graphene transistors with air-dielectric layers simply formed by folding two opposing panels. Furthermore, this realizes a wide tactile pressure sensing range from 250 Pa to ∼3 MPa. Additionally, fabrication of pressure sensor arrays and transparent pressure sensors are demonstrated, suggesting their substantial promise as next-generation electronics. PMID:28361867
Li, Chuanliang; Wu, Yingfa; Qiu, Xuanbing; Wei, Jilin; Deng, Lunhua
2017-05-01
Wavelength modulation spectroscopy (WMS) combined with a multipass absorption cell has been used to measure a weak absorption line of carbon monoxide (CO) at 1.578 µm. A 0.95m Herriott-type cell provides an effective absorption path length of 55.1 m. The WMS signals from the first and second harmonic output of a lock-in amplifier (WMS-1 f and 2 f, respectively) agree with the Beer-Lambert law, especially at low concentrations. After boxcar averaging, the minimum detection limit achieved is 4.3 ppm for a measurement time of 0.125 s. The corresponding normalized detection limit is 84 ppm m Hz -1/2 . If the integrated time is increased to 88 s, the minimum detectable limit of CO can reach to 0.29 ppm based on an Allan variation analysis. The pressure-dependent relationship is validated after accounting for the pressure factor in data processing. Finally, a linear correlation between the WMS-2 f amplitudes and gas concentrations is obtained at concentration ratios less than 15.5%, and the accuracy is better than 92% at total pressure less than 62.7 Torr.
Evaluation of an Integrated Gas-Cooled Reactor Simulator and Brayton Turbine-Generator
NASA Technical Reports Server (NTRS)
Hissam, David Andy; Stewart, Eric T.
2006-01-01
A closed-loop brayton cycle, powered by a fission reactor, offers an attractive option for generating both planetary and in-space electric power. Non-nuclear testing of this type of system provides the opportunity to safely work out integration and system control challenges for a modest investment. Recognizing this potential, a team at Marshall Space Flight Center has evaluated the viability of integrating and testing an existing gas-cooled reactor simulator and a modified commercially available, off-the-shelf, brayton turbine-generator. Since these two systems were developed independently of one another, this evaluation had to determine if they could operate together at acceptable power levels, temperatures, and pressures. Thermal, fluid, and structural analyses show that this combined system can operate at acceptable power levels and temperatures. In addition, pressure drops across the reactor simulator, although higher than desired, are also viewed as acceptable. Three potential working fluids for the system were evaluated: N2, He/Ar, and He/Xe. Other potential issues, such as electrical breakdown in the generator and the operation of the brayton foil bearings using various gas mixtures, were also investigated.
Implementation of MP3 player for music therapy on hypertension.
Yu, J Y; Huang, D F; Li, Y; Zhang, Y T
2009-01-01
Hypertension is a common clinical disease and a major risk to human health. Many clinical findings indicate that certain types of music can reduce blood pressure (BP), and music therapy is considered as an important part of anti-hypertension treatment. We integrate our former related research achievement into the new MP3 player, which can also detect the current BP value with a cuffless measurement method. According to the current BP value, the MP3 player selects certain types of music for playing in order to alleviate the hypertension of patients.
Cold Helium Gas Pressurization For Spacecraft Cryogenic Propulsion Systems
NASA Technical Reports Server (NTRS)
Morehead, Robert L.; Atwell. Matthew J.; Hurlbert, Eric A.; Melcher, J. C.
2017-01-01
To reduce the dry mass of a spacecraft pressurization system, helium pressurant may be stored at low temperature and high pressure to increase mass in a given tank volume. Warming this gas through an engine heat exchanger prior to tank pressurization both increases the system efficiency and simplifies the designs of intermediate hardware such as regulators, valves, etc. since the gas is no longer cryogenic. If this type of cold helium pressurization system is used in conjunction with a cryogenic propellant, though, a loss in overall system efficiency can be expected due to heat transfer from the warm ullage gas to the cryogenic propellant which results in a specific volume loss for the pressurant, interpreted as the Collapse Factor. Future spacecraft with cryogenic propellants will likely have a cold helium system, with increasing collapse factor effects as vehicle sizes decrease. To determine the collapse factor effects and overall implementation strategies for a representative design point, a cold helium system was hotfire tested on the Integrated Cryogenic Propulsion Test Article (ICPTA) in a thermal vacuum environment at the NASA Glenn Research Center Plum Brook Station. The ICPTA vehicle is a small lander-sized spacecraft prototype built at NASA Johnson Space Center utilizing cryogenic liquid oxygen/liquid methane propellants and cryogenic helium gas as a pressurant to operate one 2,800lbf 5:1 throttling main engine, two 28lbf Reaction Control Engines (RCE), and two 7lbf RCEs (Figure 1). This vehicle was hotfire tested at a variety of environmental conditions at NASA Plum Brook, ranging from ambient temperature/simulated high altitude, deep thermal/high altitude, and deep thermal/high vacuum conditions. A detailed summary of the vehicle design and testing campaign may be found in Integrated Cryogenic Propulsion Test Article Thermal Vacuum Hotfire Testing, AIAA JPC 2017.
Modeling and control of a brushless DC axial flow ventricular assist device.
Giridharan, Guruprasad A; Skliar, Mikhail; Olsen, Donald B; Pantalos, George M
2002-01-01
This article presents an integrated model of the human circulatory system that incorporates circulatory support by a brushless DC axial flow ventricular assist device (VAD), and a feedback VAD controller designed to maintain physiologically sufficient perfusion. The developed integrated model combines a network type model of the circulatory system with a nonlinear dynamic model of the brushless DC pump We show that maintaining a reference differential pressure between the left ventricle and aorta leads to adequate perfusion for different pathologic cases, ranging from normal heart to left heart asystole, and widely varying physical activity scenarios from rest to exercise.
Ji, Linong; Hu, Dayi; Pan, Changyu; Weng, Jianping; Huo, Yong; Ma, Changsheng; Mu, Yiming; Hao, Chuanming; Ji, Qiuhe; Ran, Xingwu; Su, Benli; Zhuo, Hanjing; Fox, Keith A A; Weber, Michael; Zhang, Danyi
2013-10-01
Individually, diabetes mellitus, hypertension, and dyslipidemia have been shown to increase the risk of cardiovascular disease. While traditional management of Type 2 diabetes has focused mainly on glycemic control, robust evidence supports the integration of hypertension and dyslipidemia management to reduce the risk of cardiovascular disease. The primary objective of this study was to assess the level of control of blood glucose, blood pressure, and blood lipids (3Bs) among patients with type 2 diabetes. An additional objective was to investigate the impact of hospital type, physician specialty, treatment pattern, and patient profile on clinical outcomes. This was a cross-sectional, multicenter observational study. A nationally representative sample of outpatients with established type 2 diabetes were enrolled at hospitals representative of geographic regions, tiers, and physician specialties in China. Main clinical measurements were the levels of glycosylated hemoglobin (HbA1c), blood pressure, and total serum cholesterol in reference to target goals. A total of 25,817 adults with type 2 diabetes (mean age 62.6 years, 47% male) were enrolled at 104 hospitals. Seventy-two percent reported comorbid hypertension, dyslipidemia, or both. Patients with concurrent type 2 diabetes, hypertension, and dyslipidemia were 6 times more likely to report a prior history of cardiovascular disease compared with those with type 2 diabetes alone. The mean HbA1c level was 7.6%. While 47.7%, 28.4%, and 36.1% of patients achieved the individual target goals for control of blood glucose (HbA1c <7%), blood pressure (systolic blood pressure <130 mm Hg, diastolic blood pressure <80 mm Hg), and blood lipids (total cholesterol <4.5 mmol/L), respectively, only 5.6% achieved all 3 target goals. Lower body mass index (<24 kg/m(2)), no active smoking or drinking, higher education, and diabetes duration <5 years were independent predictors of better cardiovascular disease risk control. Achieving adequate control of risk factors for cardiovascular disease in patients with type 2 diabetes remains a clinical challenge. Interventions to achieve control of 3Bs coupled with modification of additional cardiovascular disease predictors are crucial for optimization of clinical outcomes in patients with type 2 diabetes. Copyright © 2013 Elsevier Inc. All rights reserved.
Low-pressure membrane integrity tests for drinking water treatment: A review.
Guo, H; Wyart, Y; Perot, J; Nauleau, F; Moulin, P
2010-01-01
Low-pressure membrane systems, including microfiltration (MF) and ultrafiltration (UF) membranes, are being increasingly used in drinking water treatments due to their high level of pathogen removal. However, the pathogen will pass through the membrane and contaminate the product if the membrane integrity is compromised. Therefore, an effective on-line integrity monitoring method for MF and UF membrane systems is essential to guarantee the regulatory requirements for pathogen removal. A lot of works on low-pressure membrane integrity tests have been conducted by many researchers. This paper provides a literature review about different low-pressure membrane integrity monitoring methods for the drinking water treatment, including direct methods (pressure-based tests, acoustic sensor test, liquid porosimetry, etc.) and indirect methods (particle counting, particle monitoring, turbidity monitoring, surrogate challenge tests). Additionally, some information about the operation of membrane integrity tests is presented here. It can be realized from this review that it remains urgent to develop an alternative on-line detection technique for a quick, accurate, simple, continuous and relatively inexpensive evaluation of low-pressure membrane integrity. To better satisfy regulatory requirements for drinking water treatments, the characteristic of this ideal membrane integrity test is proposed at the end of this paper.
Deep-Sea Video Cameras Without Pressure Housings
NASA Technical Reports Server (NTRS)
Cunningham, Thomas
2004-01-01
Underwater video cameras of a proposed type (and, optionally, their light sources) would not be housed in pressure vessels. Conventional underwater cameras and their light sources are housed in pods that keep the contents dry and maintain interior pressures of about 1 atmosphere (.0.1 MPa). Pods strong enough to withstand the pressures at great ocean depths are bulky, heavy, and expensive. Elimination of the pods would make it possible to build camera/light-source units that would be significantly smaller, lighter, and less expensive. The depth ratings of the proposed camera/light source units would be essentially unlimited because the strengths of their housings would no longer be an issue. A camera according to the proposal would contain an active-pixel image sensor and readout circuits, all in the form of a single silicon-based complementary metal oxide/semiconductor (CMOS) integrated- circuit chip. As long as none of the circuitry and none of the electrical leads were exposed to seawater, which is electrically conductive, silicon integrated- circuit chips could withstand the hydrostatic pressure of even the deepest ocean. The pressure would change the semiconductor band gap by only a slight amount . not enough to degrade imaging performance significantly. Electrical contact with seawater would be prevented by potting the integrated-circuit chip in a transparent plastic case. The electrical leads for supplying power to the chip and extracting the video signal would also be potted, though not necessarily in the same transparent plastic. The hydrostatic pressure would tend to compress the plastic case and the chip equally on all sides; there would be no need for great strength because there would be no need to hold back high pressure on one side against low pressure on the other side. A light source suitable for use with the camera could consist of light-emitting diodes (LEDs). Like integrated- circuit chips, LEDs can withstand very large hydrostatic pressures. If power-supply regulators or filter capacitors were needed, these could be attached in chip form directly onto the back of, and potted with, the imager chip. Because CMOS imagers dissipate little power, the potting would not result in overheating. To minimize the cost of the camera, a fixed lens could be fabricated as part of the plastic case. For improved optical performance at greater cost, an adjustable glass achromatic lens would be mounted in a reservoir that would be filled with transparent oil and subject to the full hydrostatic pressure, and the reservoir would be mounted on the case to position the lens in front of the image sensor. The lens would by adjusted for focus by use of a motor inside the reservoir (oil-filled motors already exist).
Ultra-compact Marx-type high-voltage generator
Goerz, David A.; Wilson, Michael J.
2000-01-01
An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.
Importance of Air Absorption During Mechanical Integrity Testing
NASA Astrophysics Data System (ADS)
Arnold, Fredric C.
1990-11-01
Wells used for injection of liquid industrial waste into deep saline aquifers are required to be periodically tested for mechanical integrity. A generally accepted method to demonstrate mechanical integrity is to pressurize the casing-tubing annulus and monitor any decline in pressure. If air is used to pressurize the annulus, uncertainty may exist in differentiating between absorption of air into water in the annulus and loss of pressure due to the absence of mechanical integrity. An analytical model of air absorbance has been derived and used to quantify the pressure decline due to dissolving and diffusion of the air in annular water. A parameteric study was made to determine when annular pressure decline due to absorption of air is significant.
Design of MSR primary circuit with minimum pressure losses
NASA Astrophysics Data System (ADS)
Noga, Tomáš; Žitek, Pavel; Valenta, Václav
This article describes a design of a MSR primary circuit with minimum pressure losses. It includes a brief description of this type of a reactor and its integral layout, properties, purpose, etc. The objective of this paper is to define problems of pressure losses calculation and to design a proper device for a primary circuit of MSR reactor, including its basic dimensions. Thanks to this, it can become an initial project for a construction of a real piece of work. This is the main contribution of the carried out study. Of course, this article is not a detailed solution, but it points out facts and problems, which future designers may have to face. The further step of our work will be a reconstruction of the current experiment for a two-stage flowing.
Hetsroni, Iftach; Ben-Sira, David; Nyska, Meir; Ayalon, Moshe
2014-07-01
Plantar pressure abnormalities after open reduction with internal fixation (ORIF) of intra-articular calcaneal fractures have been observed previously, but high-grade fractures were not selectively investigated and follow-up times were shorter than 2 years. The purpose of this study was to characterize plantar pressure anomalies in patients with exclusively high-grade calcaneal fractures after ORIF with a minimum 2 years of follow-up, and to test the association between plantar pressure distribution and the clinical outcome. The orthopaedic registry was reviewed to identify patients with isolated high-grade calcaneal fractures (Sanders types III-IV) who were operated on and had a minimum 2 years of follow-up. Sixteen patients were evaluated. Mean age was 47 years and follow-up was between 2 and 6 years. The Pedar-Mobile system was used to measure 3 loading and 3 temporal variables and compare these between the operated and the uninjured limbs. Mean American Orthopaedic Foot and Ankle Society (AOFAS) score was 76 ± 7 at latest follow-up. Bohler's angle was 5 ± 8 degrees before surgery and 25 ± 7 degrees at latest follow-up. Stance was shorter in operated limbs (P = .001). Timing of the peak of pressure was delayed in operated limbs under the hallux and the second toe (P ≤ .03). Peak pressure, force time integral, and pressure time integral were increased under the lateral midfoot (P ≤ .03) and decreased under the second metatarsal (P ≤ .03). Force time integral was decreased under the first metatarsal (P = .02) and under the hallux and the lateral toes (P ≤ .05). Increased loading under the lateral midfoot and decreased loading under the lateral toes were correlated with poorer clinical outcome (r = -.53, P < .05, and r = .63, P < .01, respectively). Side-to-side plantar pressure mismatch persisted at more than 2 years after ORIF of high-grade calcaneal fractures performed via lateral approach, despite improvement of Bohler's angle. This was characterized by shortened stance phase, delayed timing of peak of pressure under the hallux and second toe, lateral load shift at the midfoot, and decreased toe pressures in operated limbs. Since loading abnormalities were correlated with the clinical outcome, modifications in treatment strategy that can improve foot loading may be desirable in these cases. Level III, case control. © The Author(s) 2014.
Modeling and control of diffusion and low-pressure chemical vapor deposition furnaces
NASA Astrophysics Data System (ADS)
De Waard, H.; De Koning, W. L.
1990-03-01
In this paper a study is made of the heat transfer inside cylindrical resistance diffusion and low-pressure chemical vapor deposition furnaces, aimed at developing an improved temperature controller. A model of the thermal behavior is derived which also covers the important class of furnaces equipped with semitransparent quartz process tubes. The model takes into account the thermal behavior of the thermocouples. It is shown that currently used temperature controllers are highly inefficient for very large scale integration applications. Based on the model an alternative temperature controller of the linear-quadratic-Gaussian type is proposed which features direct wafer temperature control. Some simulation results are given.
30 CFR 250.427 - What are the requirements for pressure integrity tests?
Code of Federal Regulations, 2010 CFR
2010-07-01
... related hole-behavior observations, such as pore-pressure test results, gas-cut drilling fluid, and well... integrity tests? 250.427 Section 250.427 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE... Operations Casing and Cementing Requirements § 250.427 What are the requirements for pressure integrity tests...
An Examination of Unsteady Airloads on a UH-60A Rotor: Computation Versus Measurement
NASA Technical Reports Server (NTRS)
Biedron, Robert T.; Lee-Rausch, Elizabeth
2012-01-01
An unsteady Reynolds-averaged Navier-Stokes solver for unstructured grids is used to simulate the flow over a UH-60A rotor. Traditionally, the computed pressure and shear stresses are integrated on the computational mesh at selected radial stations and compared to measured airloads. However, the corresponding integration of experimental data uses only the pressure contribution, and the set of integration points (pressure taps) is modest compared to the computational mesh resolution. This paper examines the difference between the traditional integration of computed airloads and an integration consistent with that used for the experimental data. In addition, a comparison of chordwise pressure distributions between computation and measurement is made. Examination of this unsteady pressure data provides new opportunities to understand differences between computation and flight measurement.
NASA Astrophysics Data System (ADS)
Lim, Dae-Kwang; Im, Ha-Ni; Song, Sun-Ju
2016-01-01
The maximum power density of SOFC with 8YSZ electrolyte as the function of thickness was calculated by integrating partial conductivities of charge carriers under various DC bias conditions at a fixed oxygen chemical potential gradient at both sides of the electrolyte. The partial conductivities were successfully taken using the Hebb-Wagner polarization method as a function of temperature and oxygen partial pressure, and the spatial distribution of oxygen partial pressure across the electrolyte was calculated based on Choudhury and Patterson’s model by considering zero electrode polarization. At positive voltage conditions corresponding to SOFC and SOEC, the high conductivity region was expanded, but at negative cell voltage condition, the low conductivity region near n-type to p-type transition was expanded. In addition, the maximum power density calculated from the current-voltage characteristic showed approximately 5.76 W/cm2 at 700 oC with 10 μm thick-8YSZ, while the oxygen partial pressure of the cathode and anode sides maintained ≈0.21 and 10-22 atm.
Integrated thruster assembly program
NASA Technical Reports Server (NTRS)
1973-01-01
The program is reported which has provided technology for a long life, high performing, integrated ACPS thruster assembly suitable for use in 100 typical flights of a space shuttle vehicle over a ten year period. The four integrated thruster assemblies (ITA) fabricated consisted of: propellant injector; a capacitive discharge, air gap torch type igniter assembly; fast response igniter and main propellant valves; and a combined regen-dump film cooled chamber. These flightweight 6672 N (1500 lb) thruster assemblies employed GH2/GO2 as propellants at a chamber pressure of 207 N/sq cm (300 psia). Test data were obtained on thrusted performance, thermal and hydraulic characteristics, dynamic response in pulsing, and cycle life. One thruster was fired in excess of 42,000 times.
Naito, Mika; Seki, Yoshimi
2009-01-01
To investigate the relation between cognitive and affective social understanding, Japanese 4- to 8-year-olds received tasks of first- and second-order false beliefs and prosocial and self-presentational display rules. From 6 to 8 years, children comprehended display rules, as well as second-order false belief, using social pressures justifications decreasingly and motivational justifications with embedded perspectives increasingly with age. Although not related to either type of display across ages, second-order tasks were associated with both types of display tasks only at 8 years when examined in each age group. Results suggest that children base their second-order theory of mind and display rules understanding on distinct reasoning until middle childhood, during which time the originally distinct aspects of social understanding are integrated.
Energy Systems High-Pressure Test Laboratory | Energy Systems Integration
Facility | NREL Energy Systems High-Pressure Test Laboratory Energy Systems High-Pressure Test Laboratory In the Energy Systems Integration Facility's High-Pressure Test Laboratory, researchers can safely test high-pressure hydrogen components. Photo of researchers running an experiment with a hydrogen fuel
Anaesthesia Gas Supply: Gas Cylinders
Srivastava, Uma
2013-01-01
Invention of oxygen cylinder was one of the most important developments in the field of medical practice. Oxygen and other gases were compressed and stored at high pressure in seamless containers constructed from hand-forged steel in1880. Materials technology has continued to evolve and now medical gas cylinders are generally made of steel alloys or aluminum. The filling pressure as well as capacity has increased considerably while at the same time the weight of cylinders has reduced. Today oxygen cylinder of equivalent size holds a third more oxygen but weighs about 20 kg less. The cylinders are of varying sizes and are color coded. They are tested at regular intervals by the manufacturer using hydraulic, impact, and tensile tests. The top end of the cylinder is fitted with a valve with a variety of number and markings stamped on it. Common valve types include: Pin index valve, bull nose, hand wheel and integral valve. The type of valve varies with cylinder size. Small cylinders have a pin index valve while large have a bull nose type. Safety features in the cylinder are: Color coding, pin index, pressure relief device, Bodok seal, and label attached etc., Safety rules and guidelines must be followed during storage, installation and use of cylinders to ensure safety of patients, hospital personnel and the environment. PMID:24249883
Anaesthesia gas supply: gas cylinders.
Srivastava, Uma
2013-09-01
Invention of oxygen cylinder was one of the most important developments in the field of medical practice. Oxygen and other gases were compressed and stored at high pressure in seamless containers constructed from hand-forged steel in1880. Materials technology has continued to evolve and now medical gas cylinders are generally made of steel alloys or aluminum. The filling pressure as well as capacity has increased considerably while at the same time the weight of cylinders has reduced. Today oxygen cylinder of equivalent size holds a third more oxygen but weighs about 20 kg less. The cylinders are of varying sizes and are color coded. They are tested at regular intervals by the manufacturer using hydraulic, impact, and tensile tests. The top end of the cylinder is fitted with a valve with a variety of number and markings stamped on it. Common valve types include: Pin index valve, bull nose, hand wheel and integral valve. The type of valve varies with cylinder size. Small cylinders have a pin index valve while large have a bull nose type. Safety features in the cylinder are: Color coding, pin index, pressure relief device, Bodok seal, and label attached etc., Safety rules and guidelines must be followed during storage, installation and use of cylinders to ensure safety of patients, hospital personnel and the environment.
Determination of the Pressure Drag of Airfoils by Integration of Surface Pressures
NASA Technical Reports Server (NTRS)
Phillips, William H.
1990-01-01
A study was conducted of the causes of pressure drag of subsonic airfoils. In a previous paper by the author, the pressure drag is obtained by calculating the total drag from the momentum defect in the boundary layer at the trailing edge and subtracting the friction drag obtained from integration of surface friction along the chord. Herein, the pressure drag is obtained by integrating the streamwise components of surface pressure around the airfoil. Studies were made to verify the accuracy of the integration procedure. The values of pressure drag were much smaller than those obtained by the previous method. This lack of agreement is attributed to the difficulty of calculating boundary layer conditions in the vicinity of the trailing edge and to the extreme sensitivity of the circulation and lift to the trailing edge conditions. The results of these studies are compared with those of previous investigations.
Exhaust Simulation Testing of a Hypersonic Airbreathing Model at Transonic Speeds
NASA Technical Reports Server (NTRS)
Huebner, Lawrence D.; Witte, David W.; Andrews, Earl H., Jr.
2004-01-01
An experimental study was performed to examine jet-effects for an airframe-integrated, scramjet-rocket combined-cycle vehicle configuration at transonic test conditions. This investigation was performed by testing an existing exhaust simulation wind tunnel model, known as Model 5B, in the NASA Langley 16-Ft. Transonic Tunnel. Tests were conducted at freestream Mach numbers from 0.7 to 1.2, at angles of attack from 2 to +14 degrees, and at up to seven nozzle static pressure ratio values for a set of horizontal-tail and body-flap deflections. The model aftbody, horizontal tails, and body flaps were extensively pressure instrumented to provide an understanding of jet-effects and control-surface/plume interactions, as well as for the development of analytical methodologies and calibration of computational fluid dynamic codes to predict this type of flow phenomenon. At all transonic test conditions examined, the exhaust flow at the exit of the internal nozzle was over-expanded, generating an exhaust plume that turned toward the aftbody. Pressure contour plots for the aftbody of Model 5B are presented for freestream transonic Mach numbers of 0.70, 0.95, and 1.20. These pressure data, along with shadowgraph images, indicated the impingement of an internal plume shock and at least one reflected shock onto the aftbody for all transonic conditions tested. These results also provided evidence of the highly three-dimensional nature of the aftbody exhaust flowfield. Parametric testing showed that angle-of-attack, static nozzle pressure ratio, and freestream Mach number all affected the exhaust-plume size, exhaust-flowfield shock structure, and the aftbody-pressure distribution, with Mach number having the largest effect. Integration of the aftbody pressure data showed large variations in the pitching moment throughout the transonic regime.
Dinato, Roberto C; Ribeiro, Ana P; Butugan, Marco K; Pereira, Ivye L R; Onodera, Andrea N; Sacco, Isabel C N
2015-01-01
To investigate the relationships between the perception of comfort and biomechanical parameters (plantar pressure and ground reaction force) during running with four different types of cushioning technology in running shoes. Randomized repeated measures. Twenty-two men, recreational runners (18-45 years) ran 12km/h with running shoes with four different cushioning systems. Outcome measures included nine items related to perception of comfort and 12 biomechanical measures related to the ground reaction forces and plantar pressures. Repeated measure ANOVAs, Pearson correlation coefficients, and step-wise multiple regression analyses were employed (p≤0.05). No significant correlations were found between the perception of comfort and the biomechanical parameters for the four types of investigated shoes. Regression analysis revealed that 56% of the perceived general comfort can be explained by the variables push-off rate and pressure integral over the forefoot (p=0.015) and that 33% of the perception of comfort over the forefoot can be explained by second peak force and push-off rate (p=0.016). The results did not demonstrate significant relationships between the perception of comfort and the biomechanical parameters for the three types of shoes investigated (Gel, Air, and ethylene-vinyl acetate). Only the shoe with Adiprene+ technology had its general comfort and cushioning perception predicted by the loads over the forefoot. Thus, in general, one cannot predict the perception of comfort of a running shoe through impact and plantar pressure received. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Evaluation of atomic pressure in the multiple time-step integration algorithm.
Andoh, Yoshimichi; Yoshii, Noriyuki; Yamada, Atsushi; Okazaki, Susumu
2017-04-15
In molecular dynamics (MD) calculations, reduction in calculation time per MD loop is essential. A multiple time-step (MTS) integration algorithm, the RESPA (Tuckerman and Berne, J. Chem. Phys. 1992, 97, 1990-2001), enables reductions in calculation time by decreasing the frequency of time-consuming long-range interaction calculations. However, the RESPA MTS algorithm involves uncertainties in evaluating the atomic interaction-based pressure (i.e., atomic pressure) of systems with and without holonomic constraints. It is not clear which intermediate forces and constraint forces in the MTS integration procedure should be used to calculate the atomic pressure. In this article, we propose a series of equations to evaluate the atomic pressure in the RESPA MTS integration procedure on the basis of its equivalence to the Velocity-Verlet integration procedure with a single time step (STS). The equations guarantee time-reversibility even for the system with holonomic constrants. Furthermore, we generalize the equations to both (i) arbitrary number of inner time steps and (ii) arbitrary number of force components (RESPA levels). The atomic pressure calculated by our equations with the MTS integration shows excellent agreement with the reference value with the STS, whereas pressures calculated using the conventional ad hoc equations deviated from it. Our equations can be extended straightforwardly to the MTS integration algorithm for the isothermal NVT and isothermal-isobaric NPT ensembles. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Sensing of Living Casualties on the Modern Integrated Battlefield
1983-11-01
spa- tial and energy resolution this technology is not considered to be appropriate to our task. Acoustic sensors including infrasonic (seismic... sonic , and ultrasonic have found application in detecting vehicle and troop movements. This type of sensor may be a useful indicator of notion and, hence...Street Columbus, OH 43210 DAVE NORDIN Monitoring of CO , Blood Resuscitation Products Manager pressure, pH, u trasound, McMinnville Division infra -red
Tissue interface pressure and skin integrity in critically ill, mechanically ventilated patients.
Grap, Mary Jo; Munro, Cindy L; Wetzel, Paul A; Schubert, Christine M; Pepperl, Anathea; Burk, Ruth S; Lucas, Valentina
2017-02-01
To describe tissue interface pressure, time spent above critical pressure levels and the effect on skin integrity at seven anatomical locations. Descriptive, longitudinal study in critically ill mechanically ventilated adults, from Surgical Trauma ICU-STICU; Medical Respiratory ICU-MRICU; Neuroscience ICU-NSICU in a Mid-Atlantic urban university medical centre. Subjects were enroled in the study within 24hours of intubation. Tissue interface pressure was measured continuously using the XSENSOR pressure mapping system (XSENSOR Technology Corporation, Calgary, Canada). Skin integrity was observed at all sites, twice daily, using the National Pressure Ulcer Advisory Panel staging system, for the first seven ICU days and at day 10 and 14. Of the 132 subjects, 90.9% had no observed changes in skin integrity. Maximum interface pressure was above 32mmHg virtually 100% of the time for the sacrum, left and right trochanter. At the 45mmHg level, the left and right trochanter had the greatest amount of time above this level (greater than 95% of the time), followed by the sacrum, left and right scapula, and the left and right heels. Similarly, at levels above 60mmHg, the same site order applied. For those six subjects with sacral skin integrity changes, maximum pressures were greater than 32mmHg 100% of the time. Four of the six sacral changes were associated with greater amounts of time above both 45mmHg and 60mmHg than the entire sample. Maximum tissue interface pressure was above critical levels for the majority of the documented periods, especially in the sacrum, although few changes in skin integrity were documented. Time spent above critical levels for mean pressures were considerably less compared to maximum pressures. Maximum pressures may have reflected pressure spikes, but the large amount of time above the critical pressure levels remains substantial. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tissue interface pressure and skin integrity in critically ill, mechanically ventilated patients☆
Grap, Mary Jo; Munro, Cindy L.; Wetzel, Paul A.; Schubert, Christine M.; Pepperl, Anathea; Burk, Ruth S.; Lucas, Valentina
2016-01-01
Summary Objective To describe tissue interface pressure, time spent above critical pressure levels and the effect on skin integrity at seven anatomical locations. Design, setting, patients Descriptive, longitudinal study in critically ill mechanically ventilated adults, from Surgical Trauma ICU-STICU; Medical Respiratory ICU-MRICU; Neuroscience ICU-NSICU in a Mid-Atlantic urban university medical centre. Subjects were enroled in the study within 24 hours of intubation. Measurements Tissue interface pressure was measured continuously using the XSENSOR pressure mapping system (XSENSOR Technology Corporation, Calgary, Canada). Skin integrity was observed at all sites, twice daily, using the National Pressure Ulcer Advisory Panel staging system, for the first seven ICU days and at day 10 and 14. Results Of the 132 subjects, 90.9% had no observed changes in skin integrity. Maximum interface pressure was above 32 mmHg virtually 100% of the time for the sacrum, left and right trochanter. At the 45 mmHg level, the left and right trochanter had the greatest amount of time above this level (greater than 95% of the time), followed by the sacrum, left and right scapula, and the left and right heels. Similarly, at levels above 60 mmHg, the same site order applied. For those six subjects with sacral skin integrity changes, maximum pressures were greater than 32 mmHg100% of the time. Four of the six sacral changes were associated with greater amounts of time above both 45 mmHg and 60 mmHg than the entire sample. Conclusions Maximum tissue interface pressure was above critical levels for the majority of the documented periods, especially in the sacrum, although few changes in skin integrity were documented. Time spent above critical levels for mean pressures were considerably less compared to maximum pressures. Maximum pressures may have reflected pressure spikes, but the large amount of time above the critical pressure levels remains substantial. PMID:27836262
40 CFR 147.3107 - Mechanical integrity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...
40 CFR 147.3107 - Mechanical integrity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...
40 CFR 147.3107 - Mechanical integrity.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...
40 CFR 147.3107 - Mechanical integrity.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted pursuant to § 146.8(b)(1) shall be preceded by an initial pressure test. A positive gauge pressure on the casing/tubing annulus (filled with liquid) shall be maintained continuously. The pressure shall be...
The Role of Radiation Pressure in the Narrow Line Regions of Seyfert Host Galaxies
NASA Astrophysics Data System (ADS)
Davies, Rebecca L.; Dopita, Michael A.; Kewley, Lisa; Groves, Brent; Sutherland, Ralph; Hampton, Elise J.; Shastri, Prajval; Kharb, Preeti; Bhatt, Harish; Scharwächter, Julia; Jin, Chichuan; Banfield, Julie; Zaw, Ingyin; James, Bethan; Juneau, Stéphanie; Srivastava, Shweta
2016-06-01
We investigate the relative significance of radiation pressure and gas pressure in the extended narrow line regions (ENLRs) of four Seyfert galaxies from the integral field Siding Spring Southern Seyfert Spectroscopic Snapshot Survey (S7). We demonstrate that there exist two distinct types of starburst-active galactic nucleus (AGN) mixing curves on standard emission line diagnostic diagrams, which reflect the balance between gas pressure and radiation pressure in the ENLR. In two of the galaxies the ENLR is radiation pressure dominated throughout and the ionization parameter remains constant (log U ˜ 0). In the other two galaxies radiation pressure is initially important, but gas pressure becomes dominant as the ionization parameter in the ENLR decreases from log U ˜ 0 to -3.2 ≲ log U ≲ -3.4. Where radiation pressure is dominant, the AGN regulates the density of the interstellar medium on kiloparsec scales and may therefore have a direct impact on star formation activity and/or the incidence of outflows in the host galaxy to scales far beyond the zone of influence of the black hole. We find that both radiation pressure dominated and gas pressure dominated ENLRs are dynamically active with evidence for outflows, indicating that radiation pressure may be an important source of AGN feedback even when it is not dominant over the entire ENLR.
Design for cyclic loading endurance of composites
NASA Technical Reports Server (NTRS)
Shiao, Michael C.; Murthy, Pappu L. N.; Chamis, Christos C.; Liaw, Leslie D. G.
1993-01-01
The application of the computer code IPACS (Integrated Probabilistic Assessment of Composite Structures) to aircraft wing type structures is described. The code performs a complete probabilistic analysis for composites taking into account the uncertainties in geometry, boundary conditions, material properties, laminate lay-ups, and loads. Results of the analysis are presented in terms of cumulative distribution functions (CDF) and probability density function (PDF) of the fatigue life of a wing type composite structure under different hygrothermal environments subjected to the random pressure. The sensitivity of the fatigue life to a number of critical structural/material variables is also computed from the analysis.
Flowsheets and source terms for radioactive waste projections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forsberg, C.W.
1985-03-01
Flowsheets and source terms used to generate radioactive waste projections in the Integrated Data Base (IDB) Program are given. Volumes of each waste type generated per unit product throughput have been determined for the following facilities: uranium mining, UF/sub 6/ conversion, uranium enrichment, fuel fabrication, boiling-water reactors (BWRs), pressurized-water reactors (PWRs), and fuel reprocessing. Source terms for DOE/defense wastes have been developed. Expected wastes from typical decommissioning operations for each facility type have been determined. All wastes are also characterized by isotopic composition at time of generation and by general chemical composition. 70 references, 21 figures, 53 tables.
Pressure vessel fracture, fatigue, and life management: PVP-Volume 233
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandari, S.; Milella, P.P.; Pennell, W.E.
1992-01-01
This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on the effects of aging. The papers are organized in the following five areas: (1) pressure vessel life management; (2) fracture characterization using local and dual-parameter approaches; (3) stratification and thermal fatigue; (4) creep, fatigue, and fracture; and (5) integrated approach to integrity assessment of pressure components. Separate abstracts were prepared for 39 papers in this conference.
TBIEM3D: A Computer Program for Predicting Ducted Fan Engine Noise. Version 1.1
NASA Technical Reports Server (NTRS)
Dunn, M. H.
1997-01-01
This document describes the usage of the ducted fan noise prediction program TBIEM3D (Thin duct - Boundary Integral Equation Method - 3 Dimensional). A scattering approach is adopted in which the acoustic pressure field is split into known incident and unknown scattered parts. The scattering of fan-generated noise by a finite length circular cylinder in a uniform flow field is considered. The fan noise is modeled by a collection of spinning point thrust dipoles. The program, based on a Boundary Integral Equation Method (BIEM), calculates circumferential modal coefficients of the acoustic pressure at user-specified field locations. The duct interior can be of the hard wall type or lined. The duct liner is axisymmetric, locally reactive, and can be uniform or axially segmented. TBIEM3D is written in the FORTRAN programming language. Input to TBIEM3D is minimal and consists of geometric and kinematic parameters. Discretization and numerical parameters are determined automatically by the code. Several examples are presented to demonstrate TBIEM3D capabilities.
Thermal and aerothermal performance of a titanium multiwall thermal protection system
NASA Technical Reports Server (NTRS)
Avery, D. E.; Shideler, J. L.; Stuckey, R. N.
1981-01-01
A metallic thermal protection system (TPS) concept the multiwall designed for temperature and pressure at Shuttle body point 3140 where the maximum surface temperature is approximately 811 K was tested to evaluate thermal performance and structural integrity. A two tile model of titanium multiwall and a model consisting of a low temperature reusable surface insulation (LRSI) tiles were exposed to 25 simulated thermal and pressure Shuttle entry missions. The two systems performed the same, and neither system deteriorated during the tests. It is indicated that redesign of the multiwall tiles reduces tile thickness and/or weight. A nine tile model of titanium multiwal was tested for radiant heating and aerothermodynamics. Minor design changes that improve structural integrity without having a significant impact on the thermal protection ability of the titanium multiwall TPS are identified. The capability of a titanium multiwall thermal protection system to protect an aluminum surface during a Shuttle type entry trajectory at locations on the vehicle where the maximum surface temperature is below 811 K is demonstrated.
The IRIS Spool-Type Reactor Coolant Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kujawski, J.M.; Kitch, D.M.; Conway, L.E.
2002-07-01
IRIS (International Reactor Innovative and Secure) is a light water cooled, 335 MWe power reactor which is being designed by an international consortium as part of the US DOE NERI Program. IRIS features an integral reactor vessel that contains all the major reactor coolant system components including the reactor core, the coolant pumps, the steam generators and the pressurizer. This integral design approach eliminates the large coolant loop piping, and thus eliminates large loss-of-coolant accidents (LOCAs) as well as the individual component pressure vessels and supports. In addition, IRIS is being designed with a long life core and enhanced safetymore » to address the requirements defined by the US DOE for Generation IV reactors. One of the innovative features of the IRIS design is the adoption of a reactor coolant pump (called 'spool' pump) which is completely contained inside the reactor vessel. Background, status and future developments of the IRIS spool pump are presented in this paper. (authors)« less
NASA Astrophysics Data System (ADS)
Yin, J. J.; Chang, F.; Li, S. L.; Yao, X. L.; Sun, J. R.; Xiao, Y.
2017-12-01
To clarify the evolution of damage for typical carbon woven fabric/epoxy laminates exposed to lightning strike, artificial lightning testing on carbon woven fabric/epoxy laminates were conducted, damage was assessed using visual inspection and damage peeling approaches. Relationships between damage size and action integral were also elucidated. Results showed that damage appearance of carbon woven fabric/epoxy laminate presents circular distribution, and center of the circle located at the lightning attachment point approximately, there exist no damage projected area dislocations for different layers, visual damage territory represents maximum damage scope; visible damage can be categorized into five modes: resin ablation, fiber fracture and sublimation, delamination, ablation scallops and block-shaped ply-lift; delamination damage due to resin pyrolysis and internal pressure exist obvious distinguish; project area of total damage is linear with action integral for the same type specimens, that of resin ablation damage is linear with action integral, but no correlation with specimen type, for all specimens, damage depth is linear with logarithm of action integral. The coupled thermal-electrical model constructed is capable to simulate the ablation damage for carbon woven fabric/epoxy laminates exposed to simulated lightning current through experimental verification.
NASA Technical Reports Server (NTRS)
Seal, Daniel W.; Weaver, Thomas L.; Kessler, Bradley L.; Bedoya, Carlos A.; Mattes, Robert E.
1994-01-01
This report describes the design, development, and testing of passive fiber optic sensors and a multiplexing electro-optic architecture (EOA) for installation and flight test on a NASA-owned F-18 aircraft. This hardware was developed under the Fiber Optic Control Systems for Advanced Aircraft program, part of a multiyear NASA initiative to design, develop, and demonstrate through flight test 'fly-by-light' systems for application to advanced aircraft flight and propulsion control. This development included the design and production of 10 passive optical sensors and associated multiplexed EOA hardware based on wavelength division multiplexed (WDM) technology. A variety of sensor types (rotary position, linear position, temperature, and pressure) incorporating a broad range of sensor technologies (WDM analog, WDM digital, analog microbend, and fluorescent time rate of decay) were obtained from different manufacturers and functionally integrated with an independently designed EOA. The sensors were built for installation in a variety of aircraft locations, placing the sensors in a variety of harsh environments. The sensors and EOA were designed and built to have the resulting devices be as close as practical to a production system. The integrated system was delivered to NASA for flight testing on a NASA-owned F-18 aircraft. Development and integration testing of the system provided valuable information as to which sensor types were simplest to design and build for a military aircraft environment and which types were simplest to operate with a multiplexed EOA. Not all sensor types met the full range of performance and environmental requirements. EOA development problems provided information on directions to pursue in future fly-by-light flight control development programs. Lessons learned in the development of the EOA and sensor hardware are summarized.
NASA Astrophysics Data System (ADS)
Seal, Daniel W.; Weaver, Thomas L.; Kessler, Bradley L.; Bedoya, Carlos A.; Mattes, Robert E.
1994-11-01
This report describes the design, development, and testing of passive fiber optic sensors and a multiplexing electro-optic architecture (EOA) for installation and flight test on a NASA-owned F-18 aircraft. This hardware was developed under the Fiber Optic Control Systems for Advanced Aircraft program, part of a multiyear NASA initiative to design, develop, and demonstrate through flight test 'fly-by-light' systems for application to advanced aircraft flight and propulsion control. This development included the design and production of 10 passive optical sensors and associated multiplexed EOA hardware based on wavelength division multiplexed (WDM) technology. A variety of sensor types (rotary position, linear position, temperature, and pressure) incorporating a broad range of sensor technologies (WDM analog, WDM digital, analog microbend, and fluorescent time rate of decay) were obtained from different manufacturers and functionally integrated with an independently designed EOA. The sensors were built for installation in a variety of aircraft locations, placing the sensors in a variety of harsh environments. The sensors and EOA were designed and built to have the resulting devices be as close as practical to a production system. The integrated system was delivered to NASA for flight testing on a NASA-owned F-18 aircraft. Development and integration testing of the system provided valuable information as to which sensor types were simplest to design and build for a military aircraft environment and which types were simplest to operate with a multiplexed EOA. Not all sensor types met the full range of performance and environmental requirements. EOA development problems provided information on directions to pursue in future fly-by-light flight control development programs. Lessons learned in the development of the EOA and sensor hardware are summarized.
Energy Systems Integration Laboratory | Energy Systems Integration Facility
systems test hub includes a Class 1, Division 2 space for performing tests of high-pressure hydrogen Laboratory offers the following capabilities. High-Pressure Hydrogen Systems The high-pressure hydrogen infrastructure. Key Infrastructure Robotic arm; high-pressure hydrogen; natural gas supply; standalone SCADA
Integrated Liquid Bismuth Propellant Feed System
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Markusic, Thomas E.; Stanojev, Boris J.
2006-01-01
A prototype bismuth propellant feed and control system was constructed and tested. An electromagnetic pump was used in this system to provide fine control of the hydrostatic pressure, and a new type of in-line flow sensor was developed to provide an accurate, real-time measurement of the mass flow rate. High-temperature material compatibility was a driving design requirement for the pump and flow sensor, leading to the selection of macor for the main body of both components. Post-test inspections of both components revealed no cracks or leaking in either. In separate proof-of-concept experiments, the pump produced a linear pressure rise as a function of current that compared favorably with theoretical pump pressure predictions, with a pressure of 10 kPa at 30 A. Flow sensing was successfully demonstrated in a bench-top test using gallium as a substitute liquid metal. A real-time controller was successfully used to control the entire system, simultaneously monitoring all power supplies and performing data acquisition duties.
Tercero, C.; Ikeda, S.; Ooe, K.; Fukuda, T.; Arai, F.; Negoro, M.; Takahashi, I.; Kwon, G.
2012-01-01
Summary In the domain of endovascular neurosurgery, the measurement of tissue integrity is needed for simulator-based training and for the development of new intravascular instruments and treatment techniques. In vitro evaluation of tissue manipulation can be achieved using photoelastic stress analysis and vasculature modeling with photoelastic materials. In this research we constructed two types of vasculature models of saccular aneurysms for differentiation of embolization techniques according to the respect for tissue integrity measurements based on the stress within the blood vessel model wall. In an aneurysm model with 5 mm dome diameter, embolization using MicroPlex 10 (Complex 1D, with 4 mm diameter loops), a maximum area of 3.97 mm2 with stress above 1 kPa was measured. This area increased to 5.50 mm2 when the dome was touched deliberately with the release mechanism of the coil, and to 4.87 mm2 for an embolization using Micrusphere, (Spherical 18 Platinum Coil). In a similar way trans-cell stent-assisted coil embolization was also compared to human blood pressure simulation using a model of a wide-necked saccular aneurysm with 7 mm diameter. The area with stress above 1kPa was below 1 mm2 for the pressure simulation and maximized at 3.79 mm2 during the trans-cell insertion of the micro-catheter and at 8.92 mm2 during the embolization. The presented results show that this measurement system is useful for identifying techniques compromising tissue integrity, comparing and studying coils and embolization techniques for a specific vasculature morphology and comparing their natural stress variations such as that produced by blood pressure. PMID:23217635
Bayesian inference for heterogeneous caprock permeability based on above zone pressure monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Namhata, Argha; Small, Mitchell J.; Dilmore, Rober
The presence of faults/ fractures or highly permeable zones in the primary sealing caprock of a CO2 storage reservoir can result in leakage of CO2. Monitoring of leakage requires the capability to detect and resolve the onset, location, and volume of leakage in a systematic and timely manner. Pressure-based monitoring possesses such capabilities. This study demonstrates a basis for monitoring network design based on the characterization of CO2 leakage scenarios through an assessment of the integrity and permeability of the caprock inferred from above zone pressure measurements. Four representative heterogeneous fractured seal types are characterized to demonstrate seal permeability rangingmore » from highly permeable to impermeable. Based on Bayesian classification theory, the probability of each fractured caprock scenario given above zone pressure measurements with measurement error is inferred. The sensitivity to injection rate and caprock thickness is also evaluated and the probability of proper classification is calculated. The time required to distinguish between above zone pressure outcomes and the associated leakage scenarios is also computed.« less
NCEL (Naval Civil Engineering Lab.) Ocean Platforms Seminar.
1983-11-01
propagating and evanescent modes. The resulting pressure field from both the scattered and radiated waves are integrated over the submerged surface of...fully submerged value. At the same time, an impact load occurs due to water entry of the member. Repeated loading of this type can result in fatigue...pronounced on deeply submerged caissons than on surface-piercing caissons. In the case of surface piercing caissons where the nonlinear effects tend to
Tessutti, Vitor; Ribeiro, Ana Paula; Trombini-Souza, Francis; Sacco, Isabel C N
2012-01-01
The practice of running has consistently increased worldwide, and with it, related lower limb injuries. The type of running surface has been associated with running injury etiology, in addition other factors, such as the relationship between the amount and intensity of training. There is still controversy in the literature regarding the biomechanical effects of different types of running surfaces on foot-floor interaction. The aim of this study was to investigate the influence of running on asphalt, concrete, natural grass, and rubber on in-shoe pressure patterns in adult recreational runners. Forty-seven adult recreational runners ran twice for 40 m on all four different surfaces at 12 ± 5% km · h(-1). Peak pressure, pressure-time integral, and contact time were recorded by Pedar X insoles. Asphalt and concrete were similar for all plantar variables and pressure zones. Running on grass produced peak pressures 9.3% to 16.6% lower (P < 0.001) than the other surfaces in the rearfoot and 4.7% to 12.3% (P < 0.05) lower in the forefoot. The contact time on rubber was greater than on concrete for the rearfoot and midfoot. The behaviour of rubber was similar to that obtained for the rigid surfaces - concrete and asphalt - possibly because of its time of usage (five years). Running on natural grass attenuates in-shoe plantar pressures in recreational runners. If a runner controls the amount and intensity of practice, running on grass may reduce the total stress on the musculoskeletal system compared with the total musculoskeletal stress when running on more rigid surfaces, such as asphalt and concrete.
40 CFR 147.3010 - Mechanical integrity tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring of annulus pressure listed in § 146.8(b)(1) of this chapter will only be acceptable if preceded by a pressure test, using liquid or gas that clearly demonstrates that mechanical integrity exists at the time of the pressure test. ...
40 CFR 147.3010 - Mechanical integrity tests.
Code of Federal Regulations, 2014 CFR
2014-07-01
... monitoring of annulus pressure listed in § 146.8(b)(1) of this chapter will only be acceptable if preceded by a pressure test, using liquid or gas that clearly demonstrates that mechanical integrity exists at the time of the pressure test. ...
40 CFR 147.3010 - Mechanical integrity tests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... monitoring of annulus pressure listed in § 146.8(b)(1) of this chapter will only be acceptable if preceded by a pressure test, using liquid or gas that clearly demonstrates that mechanical integrity exists at the time of the pressure test. ...
40 CFR 147.3010 - Mechanical integrity tests.
Code of Federal Regulations, 2013 CFR
2013-07-01
... monitoring of annulus pressure listed in § 146.8(b)(1) of this chapter will only be acceptable if preceded by a pressure test, using liquid or gas that clearly demonstrates that mechanical integrity exists at the time of the pressure test. ...
[An integrated system of blood pressure measurement with bluetooth communication].
Wang, Wei; Wang, Jing; Sun, Hongyang; Xu, Zuyang; Chai, Xinyu
2012-07-01
The development of the integrated blood pressure system with bluetooth communication function is introduced. Experimental results show that the system can complete blood pressure measurement and data transmission wireless effectively, which can be used in m-Health in future.
Capacitive Micro Pressure Sensor Integrated with a Ring Oscillator Circuit on Chip
Dai, Ching-Liang; Lu, Po-Wei; Chang, Chienliu; Liu, Cheng-Yang
2009-01-01
The study investigates a capacitive micro pressure sensor integrated with a ring oscillator circuit on a chip. The integrated capacitive pressure sensor is fabricated using the commercial CMOS (complementary metal oxide semiconductor) process and a post-process. The ring oscillator is employed to convert the capacitance of the pressure sensor into the frequency output. The pressure sensor consists of 16 sensing cells in parallel. Each sensing cell contains a top electrode and a lower electrode, and the top electrode is a sandwich membrane. The pressure sensor needs a post-CMOS process to release the membranes after completion of the CMOS process. The post-process uses etchants to etch the sacrificial layers, and to release the membranes. The advantages of the post-process include easy execution and low cost. Experimental results reveal that the pressure sensor has a high sensitivity of 7 Hz/Pa in the pressure range of 0–300 kPa. PMID:22303167
Capacitive micro pressure sensor integrated with a ring oscillator circuit on chip.
Dai, Ching-Liang; Lu, Po-Wei; Chang, Chienliu; Liu, Cheng-Yang
2009-01-01
The study investigates a capacitive micro pressure sensor integrated with a ring oscillator circuit on a chip. The integrated capacitive pressure sensor is fabricated using the commercial CMOS (complementary metal oxide semiconductor) process and a post-process. The ring oscillator is employed to convert the capacitance of the pressure sensor into the frequency output. The pressure sensor consists of 16 sensing cells in parallel. Each sensing cell contains a top electrode and a lower electrode, and the top electrode is a sandwich membrane. The pressure sensor needs a post-CMOS process to release the membranes after completion of the CMOS process. The post-process uses etchants to etch the sacrificial layers, and to release the membranes. The advantages of the post-process include easy execution and low cost. Experimental results reveal that the pressure sensor has a high sensitivity of 7 Hz/Pa in the pressure range of 0-300 kPa.
NASA Technical Reports Server (NTRS)
Morehead, R. L.; Atwell, M. J.; Melcher, J. C.; Hurlbert, E. A.
2016-01-01
Hot-fire test demonstrations were successfully conducted using a cold helium pressurization system fully integrated into a liquid oxygen (LOX) / liquid methane (LCH4) propulsion system (Figure 1). Cold helium pressurant storage at near liquid nitrogen (LN2) temperatures (-275 F and colder) and used as a heated tank pressurant provides a substantial density advantage compared to ambient temperature storage. The increased storage density reduces helium pressurant tank size and mass, creating payload increases of 35% for small lunar-lander sized applications. This degree of mass reduction also enables pressure-fed propulsion systems for human-rated Mars ascent vehicle designs. Hot-fire test results from the highly-instrumented test bed will be used to demonstrate system performance and validate integrated models of the helium and propulsion systems. A pressurization performance metric will also be developed as a means to compare different active pressurization schemes.
Miniature PT Cryocooler Activated by Resonant Piezoelectric Compressor and Passive Warm Expander
NASA Astrophysics Data System (ADS)
Sobol, S.; Grossman, G.
2017-12-01
A novel type of PZT-based compressor operating at mechanical resonance, suitable for pneumatically-driven Stirling-type cryocoolers, was presented at CEC-ICMC 2015. The detailed concept, analytical model and the test results on the preliminary prototype were reported earlier and presented at ICC17. Despite some mismatch between the impedances and insufficient structural stiffness, this compressor demonstrated the feasibility to drive our miniature Pulse Tube cryocooler MTSa, operating at 103 Hz and requiring an average PV power of 11 W, filling pressure of 40 Bar and a pressure ratio of 1.3. At ICC19 the prototype of a miniature passive warm expander (WE) was presented. The WE mechanism included a phase shifting piston suspended on a silicone diaphragm, a mass element, and a viscous damping system. Several technical drawbacks prevented perfect matching between the WE and MTSa; however, the presented prototype proved the ability to create any flow-to-pressure phase appropriate for a PT cryocooler. This paper concentrates on integration of the MTSa cryocooler with the recently modified PZT compressor operating at corrected mechanical resonance and the modified WE, which was also updated recently to match the MTSa requirements.
Berns, Veronica M; Fredrickson, Daniel C
2014-10-06
Interfaces between periodic domains play a crucial role in the properties of metallic materials, as is vividly illustrated by the way in which the familiar malleability of many metals arises from the formation and migration of dislocations. In complex intermetallics, such interfaces can occur as an integral part of the ground-state crystal structure, rather than as defects, resulting in such marvels as the NaCd2 structure (whose giant cubic unit cell contains more than 1000 atoms). However, the sources of the periodic interfaces in intermetallics remain mysterious, unlike the dislocations in simple metals, which can be associated with the exertion of physical stresses. In this Article, we propose and explore the concept of structural plasticity, the hypothesis that interfaces in complex intermetallic structures similarly result from stresses, but ones that are inherent in a defect-free parent structure, rather than being externally applied. Using DFT-chemical pressure analysis, we show how the complex structures of Ca2Ag7 (Yb2Ag7 type), Ca14Cd51 (Gd14Ag51 type), and the 1/1 Tsai-type quasicrystal approximant CaCd6 (YCd6 type) can all be traced to large negative pressures around the Ca atoms of a common progenitor structure, the CaCu5 type with its simple hexagonal 6-atom unit cell. Two structural paths are found by which the compounds provide relief to the Ca atoms' negative pressures: a Ca-rich pathway, where lower coordination numbers are achieved through defects eliminating transition metal (TM) atoms from the structure; and a TM-rich path, along which the addition of spacer Cd atoms provides the Ca coordination environments greater independence from each other as they contract. The common origins of these structures in the presence of stresses within a single parent structure highlights the diverse paths by which intermetallics can cope with competing interactions, and the role that structural plasticity may play in navigating this diversity.
Ploetz, Elizabeth A; Karunaweera, Sadish; Smith, Paul E
2015-01-28
Fluctuation solution theory has provided an alternative view of many liquid mixture properties in terms of particle number fluctuations. The particle number fluctuations can also be related to integrals of the corresponding two body distribution functions between molecular pairs in order to provide a more physical picture of solution behavior and molecule affinities. Here, we extend this type of approach to provide expressions for higher order triplet and quadruplet fluctuations, and thereby integrals over the corresponding distribution functions, all of which can be obtained from available experimental thermodynamic data. The fluctuations and integrals are then determined using the International Association for the Properties of Water and Steam Formulation 1995 (IAPWS-95) equation of state for the liquid phase of pure water. The results indicate small, but significant, deviations from a Gaussian distribution for the molecules in this system. The pressure and temperature dependence of the fluctuations and integrals, as well as the limiting behavior as one approaches both the triple point and the critical point, are also examined.
NASA Astrophysics Data System (ADS)
Ploetz, Elizabeth A.; Karunaweera, Sadish; Smith, Paul E.
2015-01-01
Fluctuation solution theory has provided an alternative view of many liquid mixture properties in terms of particle number fluctuations. The particle number fluctuations can also be related to integrals of the corresponding two body distribution functions between molecular pairs in order to provide a more physical picture of solution behavior and molecule affinities. Here, we extend this type of approach to provide expressions for higher order triplet and quadruplet fluctuations, and thereby integrals over the corresponding distribution functions, all of which can be obtained from available experimental thermodynamic data. The fluctuations and integrals are then determined using the International Association for the Properties of Water and Steam Formulation 1995 (IAPWS-95) equation of state for the liquid phase of pure water. The results indicate small, but significant, deviations from a Gaussian distribution for the molecules in this system. The pressure and temperature dependence of the fluctuations and integrals, as well as the limiting behavior as one approaches both the triple point and the critical point, are also examined.
Fong, Allan; Mittu, Ranjeev; Ratwani, Raj; Reggia, James
2014-01-01
Alarm fatigue caused by false alarms and alerts is an extremely important issue for the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the staff and hospital systems better classify a patient's waveforms and subsequent alarms. This paper explores the use of Echo State Networks, a specific type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network architectures are designed and evaluated. The results show the utility of these echo state networks, particularly ones with larger integrated reservoirs, for predicting electrocardiogram waveforms and the adaptability of such models across individuals. The work presented here offers a unique approach for understanding and predicting a patient's waveforms in order to potentially improve alarm generation. We conclude with a brief discussion of future extensions of this research.
Pressure sensitivity analysis of fiber Bragg grating sensors
NASA Astrophysics Data System (ADS)
Mrad, Nezih; Sridharan, Vasant; Kazemi, Alex
2014-09-01
Recent development in fiber optic sensing technology has mainly focused on discrete sensing, particularly, sensing systems with potential multiplexing and multi-parameter capabilities. Bragg grating fiber optic sensors have emerged as the non-disputed champion for multiplexing and simultaneous multi-parameter sensing for emerging high value structural components, advanced processing and manufacturing capabilities and increased critical infrastructure resilience applications. Although the number of potential applications for this sensing technology is large and spans the domains of medicine, manufacturing, aerospace, and public safety; critical issues such as fatigue life, sensitivity, accuracy, embeddability, material/sensor interface integrity, and universal demodulation systems still need to be addressed. The purpose of this paper is to primarily evaluate Commercial-Of-The-Shelf (COTS) Fiber Bragg Grating (FBG) sensors' sensitivity to pressure, often neglected in several applications. The COTS fiber sensitivity to pressure is further evaluated for two types of coatings (Polyimide and Acrylate), and different arrangements (arrayed and single).
NASA Astrophysics Data System (ADS)
Kolari, K.; Havia, T.; Stuns, I.; Hjort, K.
2014-08-01
Restrictor valves allow proportional control of fluid flow but are rarely integrated in microfluidic systems. In this study, an optically actuated silicon membrane restrictor microvalve is demonstrated. Its actuation is based on the phase transition of paraffin, using a paraffin wax mixed with a suitable concentration of optically absorbing nanographite particles. Backing up the membrane with oil (the melted paraffin) allows for a compliant yet strong contact to the valve seat, which enables handling of high pressures. At flow rates up to 30 µL min-1 and at a pressure of 2 bars, the valve can successfully be closed and control the flow level by restriction. The use of this paraffin composite as an adhesive layer sandwiched between the silicon valve and glass eases fabrication. This type of restrictor valve is best suited for high pressure, low volume flow silicon-based nanofluidic systems.
Skew resisting hydrodynamic seal
Conroy, William T.; Dietle, Lannie L.; Gobeli, Jeffrey D.; Kalsi, Manmohan S.
2001-01-01
A novel hydrodynamically lubricated compression type rotary seal that is suitable for lubricant retention and environmental exclusion. Particularly, the seal geometry ensures constraint of a hydrodynamic seal in a manner preventing skew-induced wear and provides adequate room within the seal gland to accommodate thermal expansion. The seal accommodates large as-manufactured variations in the coefficient of thermal expansion of the sealing material, provides a relatively stiff integral spring effect to minimize pressure-induced shuttling of the seal within the gland, and also maintains interfacial contact pressure within the dynamic sealing interface in an optimum range for efficient hydrodynamic lubrication and environment exclusion. The seal geometry also provides for complete support about the circumference of the seal to receive environmental pressure, as compared the interrupted character of seal support set forth in U.S. Pat. Nos. 5,873,576 and 6,036,192 and provides a hydrodynamic seal which is suitable for use with non-Newtonian lubricants.
Steady internal flow and aerodynamic loads analysis of shuttle thermal protection system
NASA Technical Reports Server (NTRS)
Petley, D. H.; Alexander, W., Jr.; Ivey, G. W., Jr.; Kerr, P. A.
1984-01-01
An analytical model for calculation of ascent steady state tile loading was developed and validated with wind tunnel data. The analytical model is described and results are given. Results are given for loading due to shocks and skin friction. The analysis included calculation of internal flow (porous media flow and channel flow) to obtain pressures and integration of the pressures to obtain forces and moments on an insulation tile. A heat transfer program was modified by using analogies between heat transfer and fluid flow so that it could be used for internal flow calculation. The type of insulation tile considered was undensified reusable surface insulation (RSI) without gap fillers, and the location studied was the lower surface of the orbiter. Force and moment results are reported for parameter variations on surface pressure distribution, gap sizes, insulation permeability, and tile thickness.
Smith, Michael W; Jordan, Kevin C
2014-03-25
An integrated production apparatus for production of boron nitride nanotubes via the pressure vapor-condenser method. The apparatus comprises: a pressurized reaction chamber containing a continuously fed boron containing target having a boron target tip, a source of pressurized nitrogen and a moving belt condenser apparatus; a hutch chamber proximate the pressurized reaction chamber containing a target feed system and a laser beam and optics.
NASA Technical Reports Server (NTRS)
Smith, Michael W. (Inventor); Jordan, Kevin C. (Inventor)
2014-01-01
An integrated production apparatus for production of boron nitride nanotubes via the pressure vapor-condenser method. The apparatus comprises: a pressurized reaction chamber containing a continuously fed boron containing target having a boron target tip, a source of pressurized nitrogen and a moving belt condenser apparatus; a hutch chamber proximate the pressurized reaction chamber containing a target feed system and a laser beam and optics.
NASA Astrophysics Data System (ADS)
Zhang, Hongjuan; Kurtz, Wolfgang; Kollet, Stefan; Vereecken, Harry; Franssen, Harrie-Jan Hendricks
2018-01-01
The linkage between root zone soil moisture and groundwater is either neglected or simplified in most land surface models. The fully-coupled subsurface-land surface model TerrSysMP including variably saturated groundwater dynamics is used in this work. We test and compare five data assimilation methodologies for assimilating groundwater level data via the ensemble Kalman filter (EnKF) to improve root zone soil moisture estimation with TerrSysMP. Groundwater level data are assimilated in the form of pressure head or soil moisture (set equal to porosity in the saturated zone) to update state vectors. In the five assimilation methodologies, the state vector contains either (i) pressure head, or (ii) log-transformed pressure head, or (iii) soil moisture, or (iv) pressure head for the saturated zone only, or (v) a combination of pressure head and soil moisture, pressure head for the saturated zone and soil moisture for the unsaturated zone. These methodologies are evaluated in synthetic experiments which are performed for different climate conditions, soil types and plant functional types to simulate various root zone soil moisture distributions and groundwater levels. The results demonstrate that EnKF cannot properly handle strongly skewed pressure distributions which are caused by extreme negative pressure heads in the unsaturated zone during dry periods. This problem can only be alleviated by methodology (iii), (iv) and (v). The last approach gives the best results and avoids unphysical updates related to strongly skewed pressure heads in the unsaturated zone. If groundwater level data are assimilated by methodology (iii), EnKF fails to update the state vector containing the soil moisture values if for (almost) all the realizations the observation does not bring significant new information. Synthetic experiments for the joint assimilation of groundwater levels and surface soil moisture support methodology (v) and show great potential for improving the representation of root zone soil moisture.
Advances in Materials for Recent Low-Profile Implantable Bioelectronics
Kim, Yun-Soung; Tillman, Bryan W.; Chun, Youngjae
2018-01-01
The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material’s property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities. PMID:29596359
Advances in Materials for Recent Low-Profile Implantable Bioelectronics.
Chen, Yanfei; Kim, Yun-Soung; Tillman, Bryan W; Yeo, Woon-Hong; Chun, Youngjae
2018-03-29
The rapid development of micro/nanofabrication technologies to engineer a variety of materials has enabled new types of bioelectronics for health monitoring and disease diagnostics. In this review, we summarize widely used electronic materials in recent low-profile implantable systems, including traditional metals and semiconductors, soft polymers, biodegradable metals, and organic materials. Silicon-based compounds have represented the traditional materials in medical devices, due to the fully established fabrication processes. Examples include miniaturized sensors for monitoring intraocular pressure and blood pressure, which are designed in an ultra-thin diaphragm to react with the applied pressure. These sensors are integrated into rigid circuits and multiple modules; this brings challenges regarding the fundamental material's property mismatch with the targeted human tissues, which are intrinsically soft. Therefore, many polymeric materials have been investigated for hybrid integration with well-characterized functional materials such as silicon membranes and metal interconnects, which enable soft implantable bioelectronics. The most recent trend in implantable systems uses transient materials that naturally dissolve in body fluid after a programmed lifetime. Such biodegradable metallic materials are advantageous in the design of electronics due to their proven electrical properties. Collectively, this review delivers the development history of materials in implantable devices, while introducing new bioelectronics based on bioresorbable materials with multiple functionalities.
NASA Technical Reports Server (NTRS)
Sandifer, J. P.; Denny, A.; Wood, M. A.
1985-01-01
Technical issues associated with fuel containment and damage tolerance of composite wing structures for transport aircraft were investigated. Material evaluation tests were conducted on two toughened resin composites: Celion/HX1504 and Celion/5245. These consisted of impact, tension, compression, edge delamination, and double cantilever beam tests. Another test series was conducted on graphite/epoxy box beams simulating a wing cover to spar cap joint configuration of a pressurized fuel tank. These tests evaluated the effectiveness of sealing methods with various fastener types and spacings under fatigue loading and with pressurized fuel. Another test series evaluated the ability of the selected coatings, film, and materials to prevent fuel leakage through 32-ply AS4/2220-1 laminates at various impact energy levels. To verify the structural integrity of the technology demonstration article structural details, tests were conducted on blade stiffened panels and sections. Compression tests were performed on undamaged and impacted stiffened AS4/2220-1 panels and smaller element tests to evaluate stiffener pull-off, side load and failsafe properties. Compression tests were also performed on panels subjected to Zone 2 lightning strikes. All of these data were integrated into a demonstration article representing a moderately loaded area of a transport wing. This test combined lightning strike, pressurized fuel, impact, impact repair, fatigue and residual strength.
Space shuttle aps propellant thermal conditioner study
NASA Technical Reports Server (NTRS)
Fulton, D. L.
1973-01-01
An analytical and experimental effort was completed to evaluate a baffle type thermal conditioner for superheating O2 and H2 at supercritical pressures. The thermal conditioner consisted of a heat exchanger and an integral reactor (gas generator) operating on O2/H2 propellants. Primary emphasis was placed on the hydrogen conditioner with some effort on the oxygen conditioner and a study completed of alternate concepts for use in conditioning oxygen. A hydrogen conditioner was hot fire tested under a range of conditions to establish ignition, heat exchange and response parameters. A parallel technology task was completed to further evaluate the integral reactor and heat exchanger with the side mounted electrical spark igniter.
Orbiter integrated active thermal control subsystem test
NASA Technical Reports Server (NTRS)
Jaax, J. R.
1980-01-01
Integrated subsystem level testing of the systems within the orbiter active thermal chamber capable of simulating ground, orbital, and entry temperature and pressure profiles. The test article was in a closed loop configuration that included flight type and functionally simulated protions of all ATCS components for collecting, transporting, and rejecting orbiter waste heat. Specially designed independently operating equipment simulated the transient thermal input from the cabin, payload, fuel cells, freon cold plates, hydraulic system, and space environment. Test team members using data, controls, and procedures available to a flight crew controlled the operation of the ATCS. The ATCS performance met or exceeded all thermal and operational requirements for planned and contingency mission support.
NASA Technical Reports Server (NTRS)
Vasquez, Arturo
2011-01-01
An advanced reactant pressure regulator with an internal ejector reactant circulation pump has been developed to support NASA's future fuel cell power systems needs. These needs include reliable and safe operation in variable-gravity environments, and for exploration activities with both manned and un manned vehicles. This product was developed for use in Proton Exchange Membrane Fuel Cell (PEMFC) power plant reactant circulation systems, but the design could also be applied to other fuel cell system types, (e.g., solid-oxide or alkaline) or for other gas pressure regulation and circulation needs. The regulator design includes porting for measurement of flow and pressure at key points in the system, and also includes several fuel cell system integration options. NASA has recognized ejectors as a viable alternative to mechanical pumps for use in spacecraft fuel cell power systems. The ejector motive force is provided by a variable, high-pressure supply gas that travels through the ejector s jet nozzle, whereby the pressure energy of the fluid stream is converted to kinetic energy in the gas jet. The ejector can produce circulation-to-consumption-flow ratios that are relatively high (2-3 times), and this phenomenon can potentially (with proper consideration of the remainder of the fuel cell system s design) be used to provide completely for reactant pre-humidification and product water removal in a fuel cell system. Specifically, a custom pressure regulator has been developed that includes: (1) an ejector reactant circulation pump (with interchangeable jet nozzles and mixer sections, gas-tight sliding and static seals in required locations, and internal fluid porting for pressure-sensing at the regulator's control elements) and (2) internal fluid porting to allow for flow rate and system pressure measurements. The fluid porting also allows for inclusion of purge, relief, and vacuum-breaker check valves on the regulator assembly. In addition, this regulator could also be used with NASA's advanced nonflow-through fuel cell power systems by simply incorporating a jet nozzle with an appropriate nozzle diameter.
Pressure-specific and multiple pressure response of fish assemblages in European running waters☆
Schinegger, Rafaela; Trautwein, Clemens; Schmutz, Stefan
2013-01-01
We classified homogenous river types across Europe and searched for fish metrics qualified to show responses to specific pressures (hydromorphological pressures or water quality pressures) vs. multiple pressures in these river types. We analysed fish taxa lists from 3105 sites in 16 ecoregions and 14 countries. Sites were pre-classified for 15 selected pressures to separate unimpacted from impacted sites. Hierarchical cluster analysis was used to split unimpacted sites into four homogenous river types based on species composition and geographical location. Classification trees were employed to predict associated river types for impacted sites with four environmental variables. We defined a set of 129 candidate fish metrics to select the best reacting metrics for each river type. The candidate metrics represented tolerances/intolerances of species associated with six metric types: habitat, migration, water quality sensitivity, reproduction, trophic level and biodiversity. The results showed that 17 uncorrelated metrics reacted to pressures in the four river types. Metrics responded specifically to water quality pressures and hydromorphological pressures in three river types and to multiple pressures in all river types. Four metrics associated with water quality sensitivity showed a significant reaction in up to three river types, whereas 13 metrics were specific to individual river types. Our results contribute to the better understanding of fish assemblage response to human pressures at a pan-European scale. The results are especially important for European river management and restoration, as it is necessary to uncover underlying processes and effects of human pressures on aquatic communities. PMID:24003262
Numerical Analysis of the Effects of Normalized Plasma Pressure on RMP ELM Suppression in DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orlov, D. M.; Moyer, R.A.; Evans, T. E.
2010-01-01
The effect of normalized plasma pressure as characterized by normalized pressure parameter (beta(N)) on the suppression of edge localized modes (ELMs) using resonant magnetic perturbations (RMPs) is studied in low-collisionality (nu* <= 0.2) H-mode plasmas with low-triangularity ( = 0.25) and ITER similar shapes ( = 0.51). Experimental results have suggested that ELM suppression by RMPs requires a minimum threshold in plasma pressure as characterized by beta(N). The variations in the vacuum field topology with beta(N) due to safety factor profile and island overlap changes caused by variation of the Shafranov shift and pedestal bootstrap current are examined numerically withmore » the field line integration code TRIP3D. The results show very small differences in the vacuum field structure in terms of the Chirikov (magnetic island overlap) parameter, Poincare sections and field line loss fractions. These differences do not appear to explain the observed threshold in beta(N) for ELM suppression. Linear peeling-ballooning stability analysis with the ELITE code suggests that the ELMs which persist during the RMPs when beta(N) is below the observed threshold are not type I ELMs, because the pedestal conditions are deep within the stable regime for peeling-ballooning modes. These ELMs have similarities to type III ELMs or low density ELMs.« less
Nagasukeerthi, Padakandla; Mooventhan, A; Manjunath, N K
2017-10-01
Type 2 diabetes mellitus (T2DM) is a major global health problem. Though various studies have reported the beneficial effect of Yoga in patient with T2DM, there is a lack of study in combination with bell pepper and yoga. Hence, the present study aims at evaluating short-term effect of add on bell pepper juice with integrated approach of yoga therapy (IAYT) on blood glucose levels and cardiovascular variables in patients with T2DM. Fifty T2DM subjects with the age varied from 34 to 69-years were recruited and randomly divided into either study group or control group. The study group received 100-ml of bell pepper juice (twice/day) along with IAYT while the control group received only IAYT for 4-consecutive days. Baseline and post-test assessments were taken before and after the intervention. Statistical analysis was performed using statistical package for the social sciences, version-16. Results of this study showed no significant difference in overall (fasting and post prandial) blood glucose level in the study group compared with control group. However, a significant reduction in Post prandial blood glucose (PPBG), systolic blood pressure (SBP), pulse pressure (PP), rate pressure product (RPP) and Double product (Do-P) was observed in the study group compared with control group. Results of this study suggest that though an addition of 100-ml of bell pepper juice (twice/day) along with IAYT is not more effective in reducing fasting blood glucose, it may be more effective in reducing PPBG, SBP, PP, RPP and Do-P than IAYT alone. Copyright © 2017 Elsevier Ltd. All rights reserved.
Performance Enhancement of One and Two-Shaft Industrial Turboshaft Engines Topped With Wave Rotors
NASA Astrophysics Data System (ADS)
Fatsis, Antonios
2018-05-01
Wave rotors are rotating equipment designed to exchange energy between high and low enthalpy fluids by means of unsteady pressure waves. In turbomachinery, they can be used as topping devices to gas turbines aiming to improve performance. The integration of a wave rotor into a ground power unit is far more attractive than into an aeronautical application, since it is not accompanied by any inconvenience concerning the over-weight and extra dimensioning. Two are the most common types of ground industrial gas turbines: The one-shaft and the two-shaft engines. Cycle analysis for both types of gas turbine engines topped with a four-port wave rotor is calculated and their performance is compared to the performance of the baseline engine accordingly. It is concluded that important benefits are obtained in terms of specific work and specific fuel consumption, especially compared to baseline engines with low compressor pressure ratio and low turbine inlet temperature.
Gonzalez, M E; Jernstedt, J A; Slaughter, D C; Barrett, D M
2010-09-01
The integrity of onion cells and its impact on tissue texture after high pressure and thermal processing was studied. The contribution of cell membranes and the pectic component of cell walls on the texture properties of onion tissue were analyzed. Neutral red (NR) staining of onion parenchyma cell vacuoles was used for the evaluation of cell membrane integrity and microscopic image analysis was used for its quantification. The content of methanol in tissue as a result of pectin methylesterase activity was used to evaluate the pectin component of the middle lamella and cell walls and the hardening effect on the tissue after processing. High pressure treatments consisted of 5-min holding times at 50, 100, 200, 300, or 600 MPa. Thermal treatments consisted of 30-min water bath exposure to 40, 50, 60, 70, or 90 °C. In the high pressure treatments, loss of membrane integrity commenced at 200 MPa and total loss of membrane integrity occurred at 300 MPa and above. In the thermal treatments, membrane integrity was lost between 50 and 60 °C. The texture of onions was influenced by the state of the membranes and texture profiles were abruptly modified once membrane integrity was lost. Hardening of the tissue corresponded with pressure and temperature PME activation and occurred after membrane integrity loss. The texture of vegetables is an important quality attribute that affects consumer preference. Loss of textural integrity also indicates that other biochemical reactions that affect color, flavor, and nutrient content may occur more rapidly. In this study, we analyzed changes in the texture of onions after preservation with heat and high pressure.
Integrated evaluation of visually induced motion sickness in terms of autonomic nervous regulation.
Kiryu, Tohru; Tada, Gen; Toyama, Hiroshi; Iijima, Atsuhiko
2008-01-01
To evaluate visually-induced motion sickness, we integrated subjective and objective responses in terms of autonomic nervous regulation. Twenty-seven subjects viewed a 2-min-long first-person-view video section five times (total 10 min) continuously. Measured biosignals, the RR interval, respiration, and blood pressure, were used to estimate the indices related to autonomic nervous activity (ANA). Then we determined the trigger points and some sensation sections based on the time-varying behavior of ANA-related indices. We found that there was a suitable combination of biosignals to present the symptoms of visually-induced motion sickness. Based on the suitable combination, integrating trigger points and subjective scores allowed us to represent the time-distribution of subjective responses during visual exposure, and helps us to understand what types of camera motions will cause visually-induced motion sickness.
Buldt, Andrew K; Allan, Jamie J; Landorf, Karl B; Menz, Hylton B
2018-02-23
Foot posture is a risk factor for some lower limb injuries, however the underlying mechanism is not well understood. Plantar pressure analysis is one technique to investigate the interaction between foot posture and biomechanical function of the lower limb. The aim of this review was to investigate the relationship between foot posture and plantar pressure during walking. A systematic database search was conducted using MEDLINE, CINAHL, SPORTDiscus and Embase to identify studies that have assessed the relationship between foot posture and plantar pressure during walking. Included studies were assessed for methodological quality. Meta-analysis was not conducted due to heterogeneity between studies. Inconsistencies included foot posture classification techniques, gait analysis protocols, selection of plantar pressure parameters and statistical analysis approaches. Of the 4213 citations identified for title and abstract review, sixteen studies were included and underwent quality assessment; all were of moderate methodological quality. There was some evidence that planus feet display higher peak pressure, pressure-time integral, maximum force, force-time integral and contact area predominantly in the medial arch, central forefoot and hallux, while these variables are lower in the lateral and medial forefoot. In contrast, cavus feet display higher peak pressure and pressure-time integral in the heel and lateral forefoot, while pressure-time integral, maximum force, force-time integral and contact area are lower for the midfoot and hallux. Centre of pressure was more laterally deviated in cavus feet and more medially deviated in planus feet. Overall, effect sizes were moderate, but regression models could only explain a small amount of variance in plantar pressure variables. Despite these significant findings, future research would benefit from greater methodological rigour, particularly in relation to the use of valid foot posture measurement techniques, gait analysis protocols, and standardised approaches for analysis and reporting of plantar pressure variables. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Yi; Berghaus, Melanie; Klein, Sean; Jenkins, Kelly; Zhang, Siwen; McCallum, Scott A; Morgan, Joel E; Winter, Roland; Barrick, Doug; Royer, Catherine A
2018-04-27
Many repeat proteins contain capping motifs, which serve to shield the hydrophobic core from solvent and maintain structural integrity. While the role of capping motifs in enhancing the stability and structural integrity of repeat proteins is well documented, their contribution to folding cooperativity is not. Here we examined the role of capping motifs in defining the folding cooperativity of the leucine-rich repeat protein, pp32, by monitoring the pressure- and urea-induced unfolding of an N-terminal capping motif (N-cap) deletion mutant, pp32-∆N-cap, and a C-terminal capping motif destabilization mutant pp32-Y131F/D146L, using residue-specific NMR and small-angle X-ray scattering. Destabilization of the C-terminal capping motif resulted in higher cooperativity for the unfolding transition compared to wild-type pp32, as these mutations render the stability of the C-terminus similar to that of the rest of the protein. In contrast, deletion of the N-cap led to strong deviation from two-state unfolding. In both urea- and pressure-induced unfolding, residues in repeats 1-3 of pp32-ΔN-cap lost their native structure first, while the C-terminal half was more stable. The residue-specific free energy changes in all regions of pp32-ΔN-cap were larger in urea compared to high pressure, indicating a less cooperative destabilization by pressure. Moreover, in contrast to complete structural disruption of pp32-ΔN-cap at high urea concentration, its pressure unfolded state remained compact. The contrasting effects of the capping motifs on folding cooperativity arise from the differential local stabilities of pp32, whereas the contrasting effects of pressure and urea on the pp32-ΔN-cap variant arise from their distinct mechanisms of action. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Waters, Daniel Francis
This dissertation investigates the use of gas turbine (GT) engine integrated solid oxide fuel cells (SOFCs) to reduce fuel burn in aircraft with large electrical loads like sensor-laden unmanned air vehicles (UAVs). The concept offers a number of advantages: the GT absorbs many SOFC balance of plant functions (supplying fuel, air, and heat to the fuel cell) thereby reducing the number of components in the system; the GT supplies fuel and pressurized air that significantly increases SOFC performance; heat and unreacted fuel from the SOFC are recaptured by the GT cycle offsetting system-level losses; good transient response of the GT cycle compensates for poor transient response of the SOFC. The net result is a system that can supply more electrical power more efficiently than comparable engine-generator systems with only modest (<10%) decrease in power density. Thermodynamic models of SOFCs, catalytic partial oxidation (CPOx) reactors, and three GT engine types (turbojet, combined exhaust turbofan, separate exhaust turbofan) are developed that account for equilibrium gas phase and electrochemical reaction, pressure losses, and heat losses in ways that capture `down-the-channel' effects (a level of fidelity necessary for making meaningful performance, mass, and volume estimates). Models are created in a NASA-developed environment called Numerical Propulsion System Simulation (NPSS). A sensitivity analysis identifies important design parameters and translates uncertainties in model parameters into uncertainties in overall performance. GT-SOFC integrations reduce fuel burn 3-4% in 50 kW systems on 35 kN rated engines (all types) with overall uncertainty <1%. Reductions of 15-20% are possible at the 200 kW power level. GT-SOFCs are also able to provide more electric power (factors >3 in some cases) than generator-based systems before encountering turbine inlet temperature limits. Aerodynamic drag effects of engine-airframe integration are by far the most important limiter of the combined propulsion/electrical generation concept. However, up to 100-200 kW can be produced in a bypass ratio = 8, overall pressure ratio = 40 turbofan with little or no drag penalty. This study shows that it is possible to create cooperatively integrated GT-SOFC systems for combined propulsion and power with better overall performance than stand-alone components.
Moisture sorption isotherms and thermodynamic properties of bovine leather
NASA Astrophysics Data System (ADS)
Fakhfakh, Rihab; Mihoubi, Daoued; Kechaou, Nabil
2018-04-01
This study was aimed at the determination of bovine leather moisture sorption characteristics using a static gravimetric method at 30, 40, 50, 60 and 70 °C. The curves exhibit type II behaviour according to the BET classification. The sorption isotherms fitting by seven equations shows that GAB model is able to reproduce the equilibrium moisture content evolution with water activity for moisture range varying from 0.02 to 0.83 kg/kg d.b (0.9898 < R2 < 0.999). The sorption isotherms exhibit hysteresis effect. Additionally, sorption isotherms data were used to determine the thermodynamic properties such as isosteric heat of sorption, sorption entropy, spreading pressure, net integral enthalpy and entropy. Net isosteric heat of sorption and differential entropy were evaluated through direct use of moisture isotherms by applying the Clausius-Clapeyron equation and used to investigate the enthalpy-entropy compensation theory. Both sorption enthalpy and entropy for desorption increase to a maximum with increasing moisture content, and then decrease sharply with rising moisture content. Adsorption enthalpy decreases with increasing moisture content. Whereas, adsorption entropy increases smoothly with increasing moisture content to a maximum of 6.29 J/K.mol. Spreading pressure increases with rising water activity. The net integral enthalpy seemed to decrease and then increase to become asymptotic. The net integral entropy decreased with moisture content increase.
NASA Technical Reports Server (NTRS)
Zhang, Wang; Binienda, Wieslaw K.; Pindera, Marek-Jerzy
1997-01-01
A previously developed local-global stiffness matrix methodology for the response of a composite half plane, arbitrarily layered with isotropic, orthotropic or monoclinic plies, to indentation by a rigid parabolic punch is further extended to accommodate the presence of layers with complex eigenvalues (e.g., honeycomb or piezoelectric layers). First, a generalized plane deformation solution for the displacement field in an orthotropic layer or half plane characterized by complex eigenvalues is obtained using Fourier transforms. A local stiffness matrix in the transform domain is subsequently constructed for this class of layers and half planes, which is then assembled into a global stiffness matrix for the entire multilayered half plane by enforcing continuity conditions along the interfaces. Application of the mixed boundary condition on the top surface of the half plane indented by a rigid punch results in an integral equation for the unknown pressure in the contact region. The integral possesses a divergent kernel which is decomposed into Cauchy-type and regular parts using the asymptotic properties of the local stiffness matrix and a relationship between Fourier and finite Hilbert transform of the contact pressure. The solution of the resulting singular integral equation is obtained using a collocation technique based on the properties of orthogonal polynomials developed by Erdogan and Gupta. Examples are presented that illustrate the important influence of low transverse properties of layers with complex eigenvalues, such as those exhibited by honeycomb, on the load versus contact length response and contact pressure distributions for half planes containing typical composite materials.
DEVELOPMENT OF A 4 K STIRLING-TYPE PULSE TUBE CRYOCOOLER FOR A MOBILE TERAHERTZ DETECTION SYSTEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley, P. E.; Gerecht, E.; Radebaugh, R.
2010-04-09
We discuss in this paper the design and development of a 4 K Stirling-type pulse tube cryocooler for a mobile terahertz detection system. This system integrates new heterodyne detector technology at terahertz frequencies with advancements of Stirling-type pulse tube technology that brings the advent of cooled detector sensitivities in a mobile, compact, and long duration operation system without degradation of sensitivity. To achieve this goal we reduced overall system size, input power, and temperature fluctuations and mechanical vibrations in order to maintain the detector sensitivity. The Stirling-type pulse tube cryocooler developed for this system is a hybrid design employing amore » He-4 pulse-tube cryocooler operating at 60 Hz and 2.5 MPa average pressure that precools a He-3 pulse tube cryocooler operating at 30 Hz and 1.0 MPa average pressure to achieve 4 K cooling for the terahertz receiver. The He-4 cryocooler employs stainless steel mesh regenerators for the first stage and ErPr spheres for the second stage, while the He-3 cryocooler employs stainless mesh for the first stage and ErPr spheres for the second stage with a layered rare-earth third stage regenerator. Design details and cooler performance goals are discussed.« less
Graphene-based inline pressure sensor integrated with microfluidic elastic tube
NASA Astrophysics Data System (ADS)
Inoue, Nagisa; Onoe, Hiroaki
2018-01-01
We propose an inline pressure sensor composed of a polydimethylsiloxane (PDMS) microfluidic tube integrated with graphene sheets. The PDMS tube was fabricated through molding, and a multilayered graphene sheet was transferred on the surface of the PDMS tube. The pressure inside the tube was monitored using the changes in the electrical resistance of the transferred graphene. The proposed pressure sensor could be suitable for precise pressure measurement for a small amount of fluid in microfluidic systems including organ-on-a-chip devices.
NASA Technical Reports Server (NTRS)
Scardelletti, M. C.; Jordan, J. L.; Ponchak, G. E.; Zorman, C. A.
2015-01-01
This paper presents the design, fabrication and characterization of a wireless capacitive pressure sensor with directional RF chip antenna that is envisioned for the health monitoring of aircraft engines operating in harsh environments. The sensing system is characterized from room temperature (25 C) to 300 C for a pressure range from 0 to 100 psi. The wireless pressure system consists of a Clapp-type oscillator design with a capacitive MEMS pressure sensor located in the LC-tank circuit of the oscillator. Therefore, as the pressure of the aircraft engine changes, so does the output resonant frequency of the sensing system. A chip antenna is integrated to transmit the system output to a receive antenna 10 m away.The design frequency of the wireless pressure sensor is 127 MHz and a 2 increase in resonant frequency over the temperature range of 25 to 300 C from 0 to 100 psi is observed. The phase noise is less than minus 30 dBcHz at the 1 kHz offset and decreases to less than minus 80 dBcHz at 10 kHz over the entire temperature range. The RF radiation patterns for two cuts of the wireless system have been measured and show that the system is highly directional and the MEMS pressure sensor is extremely linear from 0 to 100 psi.
NASA Technical Reports Server (NTRS)
Lakota, Barbara Anne
1998-01-01
This thesis develops a method to model the acoustic field generated by a monopole source placed in a moving rectangular duct. The walls of the duct are assumed to be infinitesimally thin and the source is placed at the center of the duct. The total acoustic pressure is written in terms of the free-space pressure, or incident pressure, and the scattered pressure. The scattered pressure is the augmentation to the incident pressure due to the presence of the duct. It satisfies a homogeneous wave equation and is discontinuous across the duct walls. Utilizing an integral representation of the scattered pressure, a set of singular boundary integral equations governing the unknown jump in scattered pressure is derived. This equation is solved by the method of collocation after representing the jump in pressure as a double series of shape functions. The solution obtained is then substituted back into the integral representation to determine the scattered pressure, and the total acoustic pressure at any point in the field. A few examples are included to illustrate the influence of various geometric and kinematic parameters on the radiated sound field.
NASA Technical Reports Server (NTRS)
Lamar, J. E.
1971-01-01
The development of a nonplanar lifting surface method having a continuous distribution of singularities and satisfying the tangent flow boundary condition on the mean camber surface is given. The method predicts some incompressible longitudinal aerodynamic coefficients of rectangular wings which have circular-arc camber. The solution method is of the integral-equation type and the resulting surface integrals are evaluated by either using numerical or analytical techniques, as are appropriate. Applications are made and the results compared with those from an exact two-dimensional circular-arc camber solution, a three-dimensional flat-wing solution which represents the camber by a projected slope onto the flat surface, and a flat-wing experiment. From these comparisons, the present method is found to predict well the flat-wing experiment and limiting values, in addition to the center of pressure variation at an angle of attack of zero for any camber. For wings having camber ratios larger than about 1.25% and moderate to high aspect ratios, the results deterioriate due to the inadequacy of lifting pressure modes employed.
46 CFR 154.419 - Design vapor pressure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Design vapor pressure. 154.419 Section 154.419 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Integral Tanks § 154.419 Design vapor pressure. The Po of an integral tank must not exceed 24.5 kPa gauge (3.55...
NASA Astrophysics Data System (ADS)
Ghaebi, Hadi; Abbaspour, Ghader
2018-05-01
In this research, thermoeconomic analysis of a multi-effect desalination thermal vapor compression (MED-TVC) system integrated with a trigeneration system with a gas turbine prime mover is carried out. The integrated system comprises of a compressor, a combustion chamber, a gas turbine, a triple-pressure (low, medium and high pressures) heat recovery steam generator (HRSG) system, an absorption chiller cycle (ACC), and a multi-effect desalination (MED) system. Low pressure steam produced in the HRSG is used to drive absorption chiller cycle, medium pressure is used in desalination system and high pressure superheated steam is used for heating purposes. For thermodynamic and thermoeconomic analysis of the proposed integrated system, Engineering Equation Solver (EES) is used by employing mass, energy, exergy, and cost balance equations for each component of system. The results of the modeling showed that with the new design, the exergy efficiency in the base design will increase to 57.5%. In addition, thermoeconomic analysis revealed that the net power, heating, fresh water and cooling have the highest production cost, respectively.
NASA Technical Reports Server (NTRS)
Panek, Joseph W.
2001-01-01
The proper operation of the Electronically Scanned Pressure (ESP) System critical to accomplish the following goals: acquisition of highly accurate pressure data for the development of aerospace and commercial aviation systems and continuous confirmation of data quality to avoid costly, unplanned, repeat wind tunnel or turbine testing. Standard automated setup and checkout routines are necessary to accomplish these goals. Data verification and integrity checks occur at three distinct stages, pretest pressure tubing and system checkouts, daily system validation and in-test confirmation of critical system parameters. This paper will give an overview of the existing hardware, software and methods used to validate data integrity.
2010-04-01
Water Kit (dry system) installed as standard Abyss second stage with integrated 30-inch braided intermediate pressure hose as standard No user...diaphragm system) installed as standard Abyss second stage with integrated 30-inch braided intermediate pressure hose as standard No user adjustments...1st Stage Regulator with Abyss 2nd Stage and Integrated Intermediate Pressure Hose ..………………………….. A-2 A3 Modified Mares Proton Ice Extreme V32
Time-dependent boundary conditions for hyperbolic systems. II
NASA Technical Reports Server (NTRS)
Thompson, Kevin W.
1990-01-01
A general boundary condition formalism is developed for all types of boundary conditions to which hyperbolic systems are subject; the formalism makes possible a 'cookbook' approach to boundary conditions, by means of which novel boundary 'recipes' may be derived and previously devised ones may be consulted as required. Numerous useful conditions are derived for such CFD problems as subsonic and supersonic inflows and outflows, nonreflecting boundaries, force-free boundaries, constant pressure boundaries, and constant mass flux. Attention is given to the computation and integration of time derivatives.
Time-dependent boundary conditions for hyperbolic systems. II
NASA Astrophysics Data System (ADS)
Thompson, Kevin W.
1990-08-01
A general boundary condition formalism is developed for all types of boundary conditions to which hyperbolic systems are subject; the formalism makes possible a 'cookbook' approach to boundary conditions, by means of which novel boundary 'recipes' may be derived and previously devised ones may be consulted as required. Numerous useful conditions are derived for such CFD problems as subsonic and supersonic inflows and outflows, nonreflecting boundaries, force-free boundaries, constant pressure boundaries, and constant mass flux. Attention is given to the computation and integration of time derivatives.
Electronic Skin with Multifunction Sensors Based on Thermosensation.
Zhao, Shuai; Zhu, Rong
2017-04-01
A multifunctional electronic skin (e-skin) with multimodal sensing capabilities of perceiving mechanical and thermal stimuli, discriminating matter type, and sensing wind is developed using the thermosensation of a platinum ribbon array, whose temperature varies with conductive or convective heat transfer toward the surroundings. Pressure is perceived by a porous elastomer covering on the heated platinum ribbon, which bears mechanical-thermal conversion to allow high integration with other sensors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Zhao, Liang; Li, Mingzhe; Wang, Liyan; Qu, Erhu; Yi, Zhuo
2018-03-01
A novel high-pressure belt-type die with a split-type cylinder is investigated with respect to extending its lifetime and improving its pressure bearing capacity. Specifically, a tungsten carbide cylinder is split into several parts along the radial direction with a prism-type cavity. In this paper, the cylinders with different split numbers are chosen to study the stress distribution and compare them with the traditional belt-type die. The simulation results indicate that the split cylinder has much smaller stress than those in the belt-type cylinder, and the statistical analysis reveals that the split-pressure cylinder is able to bear higher pressure. Experimental tests also show that the high-pressure die with a split cylinder and prism cavity has a stronger pressure-bearing capacity than a belt-type die. The split cylinder has advantages of easy manufacturing, high pressure bearing capacity, and replaceable performance.
Takenaka, Tsuneo; Kishimoto, Miyako; Ohta, Mari; Tomonaga, Osamu; Suzuki, Hiromichi
2017-05-01
The effects of sodium-glucose co-transporter type 2 inhibitors on home blood pressure were examined in type 2 diabetes with nephropathy. The patients with diabetic nephropathy were screened from medical records in our hospitals. Among them, 52 patients who measured home blood pressure and started to take sodium-glucose co-transporter type 2 inhibitors were selected. Clinical parameters including estimated glomerular filtration rate, albuminuria and home blood pressure for 6 months were analysed. Sodium-glucose co-transporter type 2 inhibitors (luseogliflozin 5 mg/day or canagliflozin 100 mg/day) reduced body weight, HbA1c, albuminuria, estimated glomerular filtration rate and office blood pressure. Although sodium-glucose co-transporter type 2 inhibitors did not alter morning blood pressure, it reduced evening systolic blood pressure. Regression analyses revealed that decreases in evening blood pressure predicted decrements in albuminuria. The present data suggest that sodium-glucose co-transporter type 2 inhibitors suppress sodium overload during daytime to reduce evening blood pressure and albuminuria.
Muscle changes with eccentric exercise: Implications on earth and in space
NASA Technical Reports Server (NTRS)
Hargens, Alan R.; Parazynski, Scott; Aratow, Michael; Friden, Jan
1989-01-01
Recent investigations of fluid pressure, morpholo gy, and enzyme activities of skeletal muscle exercised eccentrically or concentrically in normal human subjects are reviewed. Intramuscular pressures were measured before, during, and after submaximal exercise and correlated with subjective muscle soreness, fiber size, water content, and blood indices of muscle enzymes. High intensity eccentric exercise is characterized by post exercise pain, elevated intramuscular pressures, and swelling of both type 1 and 2 fibers as compared to concentric exercise. Thus, long periods of unaccustomed, high level eccentric contraction may cause muscle injury, fiber swelling, fluid accumulation, elevated intramuscular pressure, and delayed muscle soreness. Training regimens of progressively increasing eccentric exercise, however, cause less soreness and are extremely efficacious in increasing muscle mass and strength. It is proposed that on Earth, postural muscles are uniquely adapted to low levels of prolonged eccentric contraction that are absent during weightlessness. The almost complete absence of eccentric exercise in space may be an important contributor to muscle atrophy and therefore equipment should be designed to integrate eccentric contractions into exercise protocols for long-term spaceflight.
Industry structures in private dental markets in Finland.
Widström, E; Mikkola, H
2012-12-01
To use industrial organisation and organisational ecology research methods to survey industry structures and performance in the markets for private dental services and the effect of competition. Data on practice characteristics, performance, and perceived competition were collected from full-time private dentists (n = 1,121) using a questionnaire. The response rate was 59.6%. Cluster analysis was used to identify practice type based on service differentiation and process integration variables formulated from the questionnaire. Four strategic groups were identified in the Finnish markets: Solo practices formed one distinct group and group practices were classified into three clusters Integrated practices, Small practices, and Loosely integrated practices. Statistically significant differences were found in performance and perceived competitiveness between the groups. Integrated practices with the highest level of process integration and service differentiation performed better than solo and small practices. Moreover, loosely integrated and small practices outperformed solo practises. Competitive intensity was highest among small practices which had a low level of service differentiation and was above average among solo practises. Private dental care providers that had differentiated their services from public services and that had a high number of integrated service production processes enjoyed higher performance and less competitive pressures than those who had not.
Jana, Rajesh; Saha, Pinku; Pareek, Vivek; Basu, Abhisek; Kapri, Sutanu; Bhattacharyya, Sayan; Mukherjee, Goutam Dev
2016-01-01
We have carried out detailed experimental investigations on polycrystalline CuO using dielectric constant, dc resistance, Raman spectroscopy and X-ray diffraction measurements at high pressures. Observation of anomalous changes both in dielectric constant and dielectric loss in the pressure range 3.7–4.4 GPa and reversal of piezoelectric current with reversal of poling field direction indicate to a change in ferroelectric order in CuO at high pressures. A sudden jump in Raman integrated intensity of Ag mode at 3.4 GPa and observation of Curie-Weiss type behaviour in dielectric constant below 3.7 GPa lends credibility to above ferroelectric transition. A slope change in the linear behaviour of the Ag mode and a minimum in the FWHM of the same indicate indirectly to a change in magnetic ordering. Since all the previous studies show a strong spin-lattice interaction in CuO, observed change in ferroic behaviour at high pressures can be related to a reentrant multiferroic ordering in the range 3.4 to 4.4 GPa, much earlier than predicted by theoretical studies. We argue that enhancement of spin frustration due to anisotropic compression that leads to change in internal lattice strain brings the multiferroic ordering to room temperature at high pressures. PMID:27530329
NASA Astrophysics Data System (ADS)
Chróścielewski, Jacek; Schmidt, Rüdiger; Eremeyev, Victor A.
2018-05-01
This paper addresses modeling and finite element analysis of the transient large-amplitude vibration response of thin rod-type structures (e.g., plane curved beams, arches, ring shells) and its control by integrated piezoelectric layers. A geometrically nonlinear finite beam element for the analysis of piezolaminated structures is developed that is based on the Bernoulli hypothesis and the assumptions of small strains and finite rotations of the normal. The finite element model can be applied to static, stability, and transient analysis of smart structures consisting of a master structure and integrated piezoelectric actuator layers or patches attached to the upper and lower surfaces. Two problems are studied extensively: (i) FE analyses of a clamped semicircular ring shell that has been used as a benchmark problem for linear vibration control in several recent papers are critically reviewed and extended to account for the effects of structural nonlinearity and (ii) a smart circular arch subjected to a hydrostatic pressure load is investigated statically and dynamically in order to study the shift of bifurcation and limit points, eigenfrequencies, and eigenvectors, as well as vibration control for loading conditions which may lead to dynamic loss of stability.
NASA Astrophysics Data System (ADS)
Maeda, Yusaku; Maeda, Kohei; Kobara, Hideki; Mori, Hirohito; Takao, Hidekuni
2017-04-01
In this study, an integrated pressure and temperature sensor device for a flexible endoscope with long-term stability in in vivo environments was developed and demonstrated. The sensor, which is embedded in the thin wall of the disposable endoscope hood, is intended for use in endoscopic surgery. The device surface is coated with a Cr layer to prevent photoelectronic generation induced by the strong light of the endoscope. The integrated temperature sensor allows compensation for the effect of the temperature drift on a pressure signal. The fabricated device pressure resolution is 0.4 mmHg; the corresponding pressure error is 3.2 mmHg. The packaged device was used in a surgical simulation in an animal experiment. Pressure and temperature monitoring was achieved even in a pH 1 acid solution. The device enables intraluminal pressure and temperature measurements of the stomach, which facilitate the maintenance of internal stomach conditions. The applicability of the sensor was successfully demonstrated in animal experiments.
A 63 K phase change unit integrating with pulse tube cryocoolers
NASA Astrophysics Data System (ADS)
Chunhui, Kong; Liubiao, Chen; Sixue, Liu; Yuan, Zhou; Junjie, Wang
2017-02-01
This article presents the design and computer model results of an integrated cooler system which consists of a single stage pulse tube cryocooler integrated with a small amount of a phase change material. A cryogenic thermal switch was used to thermally connect the phase change unit to the cold end of the cryocooler. During heat load operation, the cryogenic thermal switch is turned off to avoid vibrations. The phase change unit absorbs heat loads by melting a substance in a constant pressure-temperature-volume process. Once the substance has been melted, the cryogenic thermal turned on, the cryocooler can then refreeze the material. Advantages of this type of cooler are no vibrations during sensor operations; the ability to absorb increased heat loads; potentially longer system lifetime; and a lower mass, volume and cost. A numerical model was constructed from derived thermodynamic relationships for the cooling/heating and freezing/melting processes.
Tang, Xiling; Remmel, Kurtis; Lan, Xinwei; Deng, Jiangdong; Xiao, Hai; Dong, Junhang
2009-09-15
Small size fiber optic devices integrated with chemically sensitive photonic materials are emerging as a new class of high-performance optical chemical sensor that have the potential to meet many analytical challenges in future clean energy systems and environmental management. Here, we report the integration of a proton conducting perovskite oxide thin film with a long-period fiber grating (LPFG) device for high-temperature in situ measurement of bulk hydrogen in fossil- and biomass-derived syngas. The perovskite-type Sr(Ce(0.8)Zr(0.1))Y(0.1)O(2.95) (SCZY) nanocrystalline thin film is coated on the 125 microm diameter LPFG by a facile polymeric precursor route. This fiber optic sensor (FOS) operates by monitoring the LPFG resonant wavelength (lambda(R)), which is a function of the refractive index of the perovskite oxide overcoat. At high temperature, the types and population of the ionic and electronic defects in the SCZY structure depend on the surrounding hydrogen partial pressure. Thus, varying the H(2) concentration changes the SCZY film refractive index and light absorbing characteristics that in turn shifts the lambda(R) of the LPFG. The SCZY-coated LPFG sensor has been demonstrated for bulk hydrogen measurement at 500 degrees C for its sensitivity, stability/reversibility, and H(2)-selectivity over other relevant small gases including CO, CH(4), CO(2), H(2)O, and H(2)S, etc.
The numerical calculation of laminar boundary-layer separation
NASA Technical Reports Server (NTRS)
Klineberg, J. M.; Steger, J. L.
1974-01-01
Iterative finite-difference techniques are developed for integrating the boundary-layer equations, without approximation, through a region of reversed flow. The numerical procedures are used to calculate incompressible laminar separated flows and to investigate the conditions for regular behavior at the point of separation. Regular flows are shown to be characterized by an integrable saddle-type singularity that makes it difficult to obtain numerical solutions which pass continuously into the separated region. The singularity is removed and continuous solutions ensured by specifying the wall shear distribution and computing the pressure gradient as part of the solution. Calculated results are presented for several separated flows and the accuracy of the method is verified. A computer program listing and complete solution case are included.
A Numerical Study of Non-hydrostatic Shallow Flows in Open Channels
NASA Astrophysics Data System (ADS)
Zerihun, Yebegaeshet T.
2017-06-01
The flow field of many practical open channel flow problems, e.g. flow over natural bed forms or hydraulic structures, is characterised by curved streamlines that result in a non-hydrostatic pressure distribution. The essential vertical details of such a flow field need to be accounted for, so as to be able to treat the complex transition between hydrostatic and non-hydrostatic flow regimes. Apparently, the shallow-water equations, which assume a mild longitudinal slope and negligible vertical acceleration, are inappropriate to analyse these types of problems. Besides, most of the current Boussinesq-type models do not consider the effects of turbulence. A novel approach, stemming from the vertical integration of the Reynolds-averaged Navier-Stokes equations, is applied herein to develop a non-hydrostatic model which includes terms accounting for the effective stresses arising from the turbulent characteristics of the flow. The feasibility of the proposed model is examined by simulating flow situations that involve non-hydrostatic pressure and/or nonuniform velocity distributions. The computational results for free-surface and bed pressure profiles exhibit good correlations with experimental data, demonstrating that the present model is capable of simulating the salient features of free-surface flows over sharply-curved overflow structures and rigid-bed dunes.
Progressive Fracture and Damage Tolerance of Composite Pressure Vessels
NASA Technical Reports Server (NTRS)
Chamis, Christos C.; Gotsis, Pascal K.; Minnetyan, Levon
1997-01-01
Structural performance (integrity, durability and damage tolerance) of fiber reinforced composite pressure vessels, designed for pressured shelters for planetary exploration, is investigated via computational simulation. An integrated computer code is utilized for the simulation of damage initiation, growth, and propagation under pressure. Aramid fibers are considered in a rubbery polymer matrix for the composite system. Effects of fiber orientation and fabrication defect/accidental damages are investigated with regard to the safety and durability of the shelter. Results show the viability of fiber reinforced pressure vessels as damage tolerant shelters for planetary colonization.
NASA Astrophysics Data System (ADS)
Asrizal; Amran, A.; Ananda, A.; Festiyed; Khairani, S.
2018-04-01
Integrated science learning and literacy skills are relevant issues in Indonesian’s education. However, the use of the integrated science learning and the integration of literacy in learning cannot be implemented well. An alternative solution of this problem is to develop integrated science instructional material on pressure in daily life theme by integrating digital age literacy. Purpose of research is to investigate the effectiveness of the use of integrated science instructional material on pressure in daily life theme to improve knowledge competence, attitudes competence and literacy skills of students. This research was a part of development research which has been conducted. In the product testing stage of this research and development was used before and after design of treatment for one sample group. Instruments to collect the data consist of learning outcomes test sheet, attitude observation sheet, and performance assessment sheet of students. Data analysis techniques include descriptive statistics analysis, normality test, homogeneity test, and paired comparison test. Therefore, the important result of research is the use of integrated science instructional material on pressure in daily life theme is effective in scientific approach to improve knowledge competence, attitudes competence, and digital age literacy skills of grade VIII students at 95% confidence level.
Shared mental models of integrated care: aligning multiple stakeholder perspectives.
Evans, Jenna M; Baker, G Ross
2012-01-01
Health service organizations and professionals are under increasing pressure to work together to deliver integrated patient care. A common understanding of integration strategies may facilitate the delivery of integrated care across inter-organizational and inter-professional boundaries. This paper aims to build a framework for exploring and potentially aligning multiple stakeholder perspectives of systems integration. The authors draw from the literature on shared mental models, strategic management and change, framing, stakeholder management, and systems theory to develop a new construct, Mental Models of Integrated Care (MMIC), which consists of three types of mental models, i.e. integration-task, system-role, and integration-belief. The MMIC construct encompasses many of the known barriers and enablers to integrating care while also providing a comprehensive, theory-based framework of psychological factors that may influence inter-organizational and inter-professional relations. While the existing literature on integration focuses on optimizing structures and processes, the MMIC construct emphasizes the convergence and divergence of stakeholders' knowledge and beliefs, and how these underlying cognitions influence interactions (or lack thereof) across the continuum of care. MMIC may help to: explain what differentiates effective from ineffective integration initiatives; determine system readiness to integrate; diagnose integration problems; and develop interventions for enhancing integrative processes and ultimately the delivery of integrated care. Global interest and ongoing challenges in integrating care underline the need for research on the mental models that characterize the behaviors of actors within health systems; the proposed framework offers a starting point for applying a cognitive perspective to health systems integration.
46 CFR 119.435 - Integral fuel tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for certification of a vessel, integral fuel tanks must withstand a hydrostatic pressure test of 35 kPa (5 psig), or the maximum pressure head to which they may be subjected in service, whichever is...
A new analytical solar radiation pressure model for current BeiDou satellites: IGGBSPM
Tan, Bingfeng; Yuan, Yunbin; Zhang, Baocheng; Hsu, Hou Ze; Ou, Jikun
2016-01-01
An analytical solar radiation pressure (SRP) model, IGGBSPM (an abbreviation for Institute of Geodesy and Geophysics BeiDou Solar Pressure Model), has been developed for three BeiDou satellite types, namely, geostationary orbit (GEO), inclined geosynchronous orbit (IGSO) and medium earth orbit (MEO), based on a ray-tracing method. The performance of IGGBSPM was assessed based on numerical integration, SLR residuals and analyses of empirical SRP parameters (except overlap computations). The numerical results show that the integrated orbit resulting from IGGBSPM differs from the precise ephemerides by approximately 5 m and 2 m for GEO and non-GEO satellites, respectively. Moreover, when IGGBSPM is used as an a priori model to enhance the ECOM (5-parameter) model with stochastic pulses, named ECOM + APR, for precise orbit determination, the SLR RMS residual improves by approximately 20–25 percent over the ECOM-only solution during the yaw-steering period and by approximately 40 percent during the yaw-fixed period. For the BeiDou GEO01 satellite, improvements of 18 and 32 percent can be achieved during the out-of-eclipse season and during the eclipse season, respectively. An investigation of the estimated ECOM D0 parameters indicated that the β-angle dependence that is evident in the ECOM-only solution is no longer present in the ECOM + APR solution. PMID:27595795
A new analytical solar radiation pressure model for current BeiDou satellites: IGGBSPM.
Tan, Bingfeng; Yuan, Yunbin; Zhang, Baocheng; Hsu, Hou Ze; Ou, Jikun
2016-09-06
An analytical solar radiation pressure (SRP) model, IGGBSPM (an abbreviation for Institute of Geodesy and Geophysics BeiDou Solar Pressure Model), has been developed for three BeiDou satellite types, namely, geostationary orbit (GEO), inclined geosynchronous orbit (IGSO) and medium earth orbit (MEO), based on a ray-tracing method. The performance of IGGBSPM was assessed based on numerical integration, SLR residuals and analyses of empirical SRP parameters (except overlap computations). The numerical results show that the integrated orbit resulting from IGGBSPM differs from the precise ephemerides by approximately 5 m and 2 m for GEO and non-GEO satellites, respectively. Moreover, when IGGBSPM is used as an a priori model to enhance the ECOM (5-parameter) model with stochastic pulses, named ECOM + APR, for precise orbit determination, the SLR RMS residual improves by approximately 20-25 percent over the ECOM-only solution during the yaw-steering period and by approximately 40 percent during the yaw-fixed period. For the BeiDou GEO01 satellite, improvements of 18 and 32 percent can be achieved during the out-of-eclipse season and during the eclipse season, respectively. An investigation of the estimated ECOM D0 parameters indicated that the β-angle dependence that is evident in the ECOM-only solution is no longer present in the ECOM + APR solution.
Arduino and Nagios integration for monitoring
NASA Astrophysics Data System (ADS)
Fernández, V.; Pazos, A.; Saborido, J.; Seco, M.
2014-06-01
The data centre at the Galician Institute of High Energy Physics (IGFAE) of the Santiago de Compostela University (USC) is a computing cluster with about 150 nodes and 1250 cores that hosts the LHCb Tiers 2 and 3. In this small data centre, and of course in similar or bigger ones, it is very important to keep optimal conditions of temperature, humidity and pressure. Therefore, it is a necessity to monitor the environment and be able to trigger alarms when operating outside the recommended settings. There are currently many tools and systems developed for data centre monitoring, but until recent years all of them were of commercial nature and expensive. In recent years there has been an increasing interest in the use of technologies based on Arduino due to its open hardware licensing and the low cost of this type of components. In this article we describe the system developed to monitor IGFAE's data centre, which integrates an Arduino controlled sensor network with the Nagios monitoring software. Sensors of several types, temperature, humidity and pressure, are connected to the Arduino board. The Nagios software is in charge of monitoring the various sensors and, with the help of Nagiosgraph, to keep track of the historic data and to produce the plots. An Arduino program, developed in house, provides the Nagios plugin with the readout of one or several sensors depending on the plugin's request. The Nagios plugin for reading the temperature sensors also broadcasts an SNMP trap when the temperature gets out of the allowed operating range.
Mandel, Susan E; Davis, Beth A; Secic, Michelle
2013-01-01
The purpose of the feasibility study was to compare the effects of music-assisted relaxation and imagery, administered via compact disc recording (MARI CD) without therapeutic intervention, to the effects of music therapy (MT), facilitated by a board-certified music therapist, on selected health outcomes of patients enrolled in diabetes self-management education/training (DSME/T). A 3-group, parallel, randomized controlled trial with 199 patients, aged 30 to 85 years with type 1, type 2, or prediabetes was employed. Patients were enrolled in a study from 2 hospital sites and randomly assigned to: DSME/T alone, DSME/T plus MARI CD, or DSME/T plus MT. The MARI CD included researcher-selected music and spoken suggestions, while MT included therapeutic experiences with personally preferred relaxing and energizing music. Outcome measures included blood pressure, glycosylated hemoglobin (A1C), body mass index (BMI), trait anxiety, state anxiety, and stress. There were no statistically significant differences among the 3 conditions in blood pressure, A1C, BMI, trait anxiety, or stress. Significant changes over time were evident in the MT condition from pre- to post-each session in systolic blood pressure, state anxiety, and stress. Blood pressure changes were compared pre- to postprogram for those patients with a comorbidity of hypertension between DSME/T alone and a combined music intervention group (MT and MARI CD). It was found that the music intervention group had a significantly larger decrease in systolic blood pressure. Themes derived from patient narratives further informed the data. The study results support the relationship between DSME/T and improvement on all measured outcomes except blood pressure. Results suggest the feasibility of integrating MARI and MT with DSME/T to potentially lower systolic blood pressure of patients with diabetes and a comorbidity of hypertension. Collaboration between diabetes educators and board-certified music therapists is recommended.
Titov, V N; Dmitriev, V A; Oshchepkov, E V; Balakhonova, T V; Tripoten', M I; Shiriaeva, Iu K
2012-08-01
The article deals with studying of the relationship between biologic reaction of inflammation with glycosylation reaction and content of methylglyoxal in blood serum. The positive correlation between pulse wave velocity and content of methylglyoxal, C-reactive protein in intercellular medium and malleolar brachial index value was established. This data matches the experimental results concerning involvement of biological reaction of inflammation into structural changes of elastic type arteries under hypertension disease, formation of arteries' rigidity and increase of pulse wave velocity. The arterial blood pressure is a biological reaction of hydrodynamic pressure which is used in vivo by several biological functions: biological function of homeostasis, function of endoecology, biological function of adaptation and function of locomotion. The biological reaction of hydrodynamic (hydraulic) pressure is a mode of compensation of derangement of several biological functions which results in the very high rate of hypertension disease in population. As a matter of fact, hypertension disease is a syndrome of lingering pathological compensation by higher arterial blood pressure of the biological functions derangements occurring in the distal section at the level of paracrine cenoses of cells. The arterial blood pressure is a kind of in vivo integral indicator of deranged metabolism. The essential hypertension disease pathogenically is a result of the derangement of three biological functions: biological function of homeostasis, biological function of trophology - nutrition (biological reaction of external feeding - exotrophia) and biological function of endoecology. In case of "littering" of intercellular medium in vivo with nonspecific endogenic flogogens a phylogenetically earlier activation of biological reactions of excretion, inflammation and hydrodynamic arterial blood pressure occur. In case of derangement of biological function of homeostasis, decreasing of perfusion even in single paracrine cenoses and derangement of biological function of endoecology ("purity" of intercellular medium) the only response always will be the increase of arterial blood pressure.
Total nasal resistance among Sasang constitutional types: a population-based study in Korea
2013-01-01
Background There have been many attempts to find an objective phenotype by Sasang constitutional types (SCTs) on an anatomical, physiological, and psychological basis, but there has been no research on total nasal resistance (TNR) among SCTs. Methods We assessed the value of the TNR in the SCTs classified by an integrated diagnostic model. Included in the study were 1,346 individuals (701 males, 645 females) who participated in the Korean Genome and Epidemiology Study (KoGES). The TNR was measured by active anterior rhinomanometry (AAR) at transnasal pressures of 100 and 150 Pascal (Pa). Results The average TNR was 0.186 ± 0.004 Pa/cm3/second at 100 Pa in the Tae-eum (TE), 0.193 ± 0.007 in the So-eum (SE), and 0.208 ± 0.005 in the So-yang (SY) types. Under condition of 150 Pa the TE type had a TNR value of 0.217 ± 0.004, the SE type was 0.230 ± 0.008, and the SY type was 0.243 ± 0.005. Higher values of TNR were more likely to be reported in the SY type at 100 Pa and 150 Pa. In the stratified analysis by sex, the SY type in males and females tended to have higher TNR value than the TE and SE types at transnasal pressure of both 100 Pa and 150 Pa. Conclusions These results provide new approaches to understand the functional characteristics among the SCTs in terms of nasal physiology. Further studies are required to clarify contributing factors for such a difference. PMID:24180585
Zanobetti, Antonella; Luttmann-Gibson, Heike; Horton, Edward S; Cohen, Allison; Coull, Brent A; Hoffmann, Barbara; Schwartz, Joel D; Mittleman, Murray A; Li, Yongsheng; Stone, Peter H; de Souza, Celine; Lamparello, Brooke; Koutrakis, Petros; Gold, Diane R
2014-03-01
Extreme weather and air pollution are associated with increased cardiovascular risk in people with diabetes. In a population with diabetes, we conducted a novel assessment of vascular brachial artery responses both to ambient pollution and to weather (temperature and water vapor pressure, a measure of humidity). Sixty-four 49- to 85-year-old Boston residents with type 2 diabetes completed up to five study visits (279 repeated measures). Brachial artery diameter (BAD) was measured by ultrasound before and after brachial artery occlusion [i.e., flow-mediated dilation (FMD)] and before and after nitroglycerin-mediated dilation (NMD). Ambient concentrations of fine particulate mass (PM2.5), black carbon (BC), organic carbon (OC), elemental carbon, particle number, and sulfate were measured at our monitoring site; ambient concentrations of carbon monoxide, nitrogen dioxide, and ozone were obtained from state monitors. Particle exposure in the home and during each trip to the clinic (home/trip exposure) was measured continuously and as a 5-day integrated sample. We used linear models with fixed effects for participants, adjusting for date, season, temperature, and water vapor pressure on the day of each visit, to estimate associations between our outcomes and interquartile range increases in exposure. Baseline BAD was negatively associated with particle pollution, including home/trip-integrated BC (-0.02 mm; 95% CI: -0.04, -0.003, for a 0.28 μg/m3 increase in BC), OC (-0.08 mm; 95% CI: -0.14, -0.03, for a 1.61 μg/m3 increase) as well as PM2.5, 5-day average ambient PM2.5, and BC. BAD was positively associated with ambient temperature and water vapor pressure. However, exposures were not consistently associated with FMD or NMD. Brachial artery diameter, a predictor of cardiovascular risk, decreased in association with particle pollution and increased in association with ambient temperature in our study population of adults with type 2 diabetes. Zanobetti A, Luttmann-Gibson H, Horton ES, Cohen A, Coull BA, Hoffmann B, Schwartz JD, Mittleman MA, Li Y, Stone PH, de Souza C, Lamparello B, Koutrakis P, Gold DR. 2014. Brachial artery responses to ambient pollution, temperature, and humidity in people with type 2 diabetes: a repeated-measures study. Environ Health Perspect 122:242-248; http://dx.doi.org/10.1289/ehp.1206136.
Integrated fault seal analysis and risk assessemt: Okan and Meren Fields, Nigeria
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eisenberg, R.A.; Brenneman, R.J.; Adepoju, A.A.
1996-01-01
Integration of production, geochemical, seismic, well log, and structural data provides important constraints on the sealing capacity and dynamic behavior of fault juxtaposed reservoirs in Okan and Meren fields, offshore Nigeria. Correlations were found between pressure decline histories, juxtaposed fluid types, oil composition, fluid contact relationships, fault sealing/leaking condition, and estimates of the composition of the fault gouge. Fault plane sections defined reservoir juxtapositions and potential cross-fault spill points. Smear gouge ratios calculated from E-logs were used to estimate the composition of fault-gouge materials between juxtaposed reservoirs. These tools augmented interpretation of seal/nonseal character in proved reservoirs and were usedmore » to quantify fault seal risk of untested, fault-dependent closures. In the Okan Field juxtapositions of the G-, H, L-, M, and O-sands were analyzed. Smear gouge ratios correlated to fluid contact relationships and pressure decline histories within these juxtaposed reservoirs empirically calibrate sealing potential. The results of these analyses were then used to interpret production-induced fault seal breakdown within the G-sands and to risk seal integrity of fault-dependent closures within the untested 0-sands in an adjacent, upthrown fault block. Within this fault block the presence of potential fault intersection leak points and large areas of sand/sand juxtaposition with high smear gouge ratios (low sealing potential) limits column heights and potential reserves within the O-sand package. In the Meren Field the E- and G-sands are juxtaposed, on different pressure decline, geochemically distinct, and are characterized by low smear gouge ratios. In contrast, the G- and H-sands, juxtaposed across the same fault, contain similar OOWCs and are characterized by high smear gouge ratios.« less
Bhattacharya, S.; Doveton, J.H.; Carr, T.R.; Guy, W.R.; Gerlach, P.M.
2005-01-01
Small independent operators produce most of the Mississippian carbonate fields in the United States mid-continent, where a lack of integrated characterization studies precludes maximization of hydrocarbon recovery. This study uses integrative techniques to leverage extant data in an Osagian and Meramecian (Mississippian) cherty carbonate reservoir in Kansas. Available data include petrophysical logs of varying vintages, limited number of cores, and production histories from each well. A consistent set of assumptions were used to extract well-level porosity and initial saturations, from logs of different types and vintages, to build a geomodel. Lacking regularly recorded well shut-in pressures, an iterative technique, based on material balance formulations, was used to estimate average reservoir-pressure decline that matched available drillstem test data and validated log-analysis assumptions. Core plugs representing the principal reservoir petrofacies provide critical inputs for characterization and simulation studies. However, assigning plugs among multiple reservoir petrofacies is difficult in complex (carbonate) reservoirs. In a bottom-up approach, raw capillary pressure (Pc) data were plotted on the Super-Pickett plot, and log- and core-derived saturation-height distributions were reconciled to group plugs by facies, to identify core plugs representative of the principal reservoir facies, and to discriminate facies in the logged interval. Pc data from representative core plugs were used for effective pay evaluation to estimate water cut from completions, in infill and producing wells, and guide-selective perforations for economic exploitation of mature fields. The results from this study were used to drill 22 infill wells. Techniques demonstrated here can be applied in other fields and reservoirs. Copyright ?? 2005. The American Association of Petroleum Geologists. All rights reserved.
Integrated fault seal analysis and risk assessemt: Okan and Meren Fields, Nigeria
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eisenberg, R.A.; Brenneman, R.J.; Adepoju, A.A.
Integration of production, geochemical, seismic, well log, and structural data provides important constraints on the sealing capacity and dynamic behavior of fault juxtaposed reservoirs in Okan and Meren fields, offshore Nigeria. Correlations were found between pressure decline histories, juxtaposed fluid types, oil composition, fluid contact relationships, fault sealing/leaking condition, and estimates of the composition of the fault gouge. Fault plane sections defined reservoir juxtapositions and potential cross-fault spill points. Smear gouge ratios calculated from E-logs were used to estimate the composition of fault-gouge materials between juxtaposed reservoirs. These tools augmented interpretation of seal/nonseal character in proved reservoirs and were usedmore » to quantify fault seal risk of untested, fault-dependent closures. In the Okan Field juxtapositions of the G-, H, L-, M, and O-sands were analyzed. Smear gouge ratios correlated to fluid contact relationships and pressure decline histories within these juxtaposed reservoirs empirically calibrate sealing potential. The results of these analyses were then used to interpret production-induced fault seal breakdown within the G-sands and to risk seal integrity of fault-dependent closures within the untested 0-sands in an adjacent, upthrown fault block. Within this fault block the presence of potential fault intersection leak points and large areas of sand/sand juxtaposition with high smear gouge ratios (low sealing potential) limits column heights and potential reserves within the O-sand package. In the Meren Field the E- and G-sands are juxtaposed, on different pressure decline, geochemically distinct, and are characterized by low smear gouge ratios. In contrast, the G- and H-sands, juxtaposed across the same fault, contain similar OOWCs and are characterized by high smear gouge ratios.« less
Proof Of Concept of Integrated Load Measurement in 3D Printed Structures
Hinderdael, Michael; Strantza, Maria; De Baere, Dieter; ...
2017-02-09
Currently, research on structural health monitoring systems is focused on direct integration of the system into a component or structure. The latter results in a so-called smart structure. One example of a smart structure is a component with integrated strain sensing for continuous load monitoring. Additive manufacturing, or 3D printing, now also enables such integration of functions inside components. As a proof-of-concept, the Fused Deposition Modeling (FDM) technique was used to integrate a strain sensing element inside polymer (ABS) tensile test samples. The strain sensing element consisted of a closed capillary filled with a fluid and connected to an externallymore » mounted pressure sensor. The volumetric deformation of the integrated capillary resulted in pressure changes in the fluid. The obtained pressure measurements during tensile testing are reported in this paper and compared to state-of-the-art extensometer measurements. The sensitivity of the 3D printed pressure-based strain sensor is primarily a function of the compressibility of the capillary fluid. Air- and watertightness are of critical importance for the proper functioning of the 3D printed pressure-based strain sensor. Therefore, the best after-treatment procedure was selected on basis of a comparative analysis. The obtained pressure measurements are linear with respect to the extensometer readings, and the uncertainty on the strain measurement of a capillary filled with water (incompressible fluid) is ±3.1 µstrain, which is approximately three times less sensitive than conventional strain gauges (±1 µstrain), but 32 times more sensitive than the same sensor based on air (compressible fluid) (±101 µstrain).« less
Proof Of Concept of Integrated Load Measurement in 3D Printed Structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinderdael, Michael; Strantza, Maria; De Baere, Dieter
Currently, research on structural health monitoring systems is focused on direct integration of the system into a component or structure. The latter results in a so-called smart structure. One example of a smart structure is a component with integrated strain sensing for continuous load monitoring. Additive manufacturing, or 3D printing, now also enables such integration of functions inside components. As a proof-of-concept, the Fused Deposition Modeling (FDM) technique was used to integrate a strain sensing element inside polymer (ABS) tensile test samples. The strain sensing element consisted of a closed capillary filled with a fluid and connected to an externallymore » mounted pressure sensor. The volumetric deformation of the integrated capillary resulted in pressure changes in the fluid. The obtained pressure measurements during tensile testing are reported in this paper and compared to state-of-the-art extensometer measurements. The sensitivity of the 3D printed pressure-based strain sensor is primarily a function of the compressibility of the capillary fluid. Air- and watertightness are of critical importance for the proper functioning of the 3D printed pressure-based strain sensor. Therefore, the best after-treatment procedure was selected on basis of a comparative analysis. The obtained pressure measurements are linear with respect to the extensometer readings, and the uncertainty on the strain measurement of a capillary filled with water (incompressible fluid) is ±3.1 µstrain, which is approximately three times less sensitive than conventional strain gauges (±1 µstrain), but 32 times more sensitive than the same sensor based on air (compressible fluid) (±101 µstrain).« less
Proof of Concept of Integrated Load Measurement in 3D Printed Structures
Hinderdael, Michaël; Jardon, Zoé; Lison, Margot; De Baere, Dieter; Devesse, Wim; Strantza, Maria; Guillaume, Patrick
2017-01-01
Currently, research on structural health monitoring systems is focused on direct integration of the system into a component or structure. The latter results in a so-called smart structure. One example of a smart structure is a component with integrated strain sensing for continuous load monitoring. Additive manufacturing, or 3D printing, now also enables such integration of functions inside components. As a proof-of-concept, the Fused Deposition Modeling (FDM) technique was used to integrate a strain sensing element inside polymer (ABS) tensile test samples. The strain sensing element consisted of a closed capillary filled with a fluid and connected to an externally mounted pressure sensor. The volumetric deformation of the integrated capillary resulted in pressure changes in the fluid. The obtained pressure measurements during tensile testing are reported in this paper and compared to state-of-the-art extensometer measurements. The sensitivity of the 3D printed pressure-based strain sensor is primarily a function of the compressibility of the capillary fluid. Air- and watertightness are of critical importance for the proper functioning of the 3D printed pressure-based strain sensor. Therefore, the best after-treatment procedure was selected on basis of a comparative analysis. The obtained pressure measurements are linear with respect to the extensometer readings, and the uncertainty on the strain measurement of a capillary filled with water (incompressible fluid) is ±3.1 µstrain, which is approximately three times less sensitive than conventional strain gauges (±1 µstrain), but 32 times more sensitive than the same sensor based on air (compressible fluid) (±101 µstrain). PMID:28208779
In-line pressure within a HOTLINE® Fluid Warmer, under various flow conditions.
Higashi, Midoriko; Yamaura, Ken; Matsubara, Yukie; Fukudome, Takuya; Hoka, Sumio
2015-04-01
Roller pump infusion devices are widely used for rapid infusion, and may be combined with separate warming devices. There may be instances however, where the pressures generated by the roller pump may not be compatible with the warming device. We assessed a commonly used roller pump in combination with a HOTLINE® Fluid Warmer, and found that it could generate pressures exceeding the HOTLINE® manufacturers specifications. This was of concern because the HOTLINE® manufacturer guideline states that not for use with pressure devices generating over 300 mmHg. Pressure greater than 300 mmHg may compromise the integrity of the HOTLINE® Fluid Warming Set. The aim of this study was to compare in-line pressure within a HOTLINE® Fluid Warmer at different infusion rates of a roller pump using various sizes of intravenous cannulae. The rapid infusion system comprised a 500 mL-normal saline bag, roller pump type infusion device, HOTLINE® Fluid Warmer (blood and fluid warmer system), and six different sizes of intravenous cannulae. In-line pressure was measured proximal to the HOTLINE® (pre-warmer) and proximal to the cannula (post-warmer), at flow rate of 50-160 mL/min. The in-line pressures increased significantly with increasing flow rate. The pre-warmer pressures exceeded 300 mmHg when the flow rate was ≥120 mL/min with 20-gauge, 48 mm length cannula, 130 with 20-gauge, 25 mm cannula, and 160 mL/min with 18-gauge, 48 mm cannula. However, they were <300 mmHg at any flow rates with 18-gauge, 30 mm cannula and 16-gauge cannulae. The post-warmer pressures exceeded 300 mmHg at the flow rate of 140 mL/min with 20-gauge, 48 mm cannula, and 160 mL/min with 20-gauge, 25 mm cannula, while they were <300 mmHg at any flow rates with 18 and 16-gauge cannulae. The in-line pressure within a HOTLINE® could exceed 300 mmHg, depending on the flow rate and size and length of cannula. It is important to pay attention to the size and length of cannulae and flow rate to keep the maximum in-line pressure<300 mmHg when a roller pump type infusion device is used.
NASA Technical Reports Server (NTRS)
Hardin, R. B.; Burrows, R. R.
1975-01-01
The purpose of the test was to determine the effects of cold jet gas plumes on (1) the integrated vehicle longitudinal and lateral-directional force data, (2) exposed wing hinge moment, (3) wing pressure distributions, (4) orbiter MPS external pressure distributions, and (5) model base pressures. An investigation was undertaken to determine the similarity between solid and gaseous plumes; fluorescent oil flow visualization studies were also conducted. Plotted wing pressure data is tabulated.
Studies on pressure-gain combustion engines
NASA Astrophysics Data System (ADS)
Matsutomi, Yu
Various aspects of the pressure-gain combustion engine are investigated analytically and experimentally in the current study. A lumped parameter model is developed to characterize the operation of a valveless pulse detonation engine. The model identified the function of flame quenching process through gas dynamic process. By adjusting fuel manifold pressure and geometries, the duration of the air buffer can be effectively varied. The parametric study with the lumped parameter model has shown that engine frequency of up to approximately 15 Hz is attainable. However, requirements for upstream air pressure increases significantly with higher engine frequency. The higher pressure requirement indicates pressure loss in the system and lower overall engine performance. The loss of performance due to the pressure loss is a critical issue for the integrated pressure-gain combustors. Two types of transitional methods are examined using entropy-based models. An accumulator based transition has obvious loss due to sudden area expansion, but it can be minimized by utilizing the gas dynamics in the combustion tube. An ejector type transition has potential to achieve performance beyond the limit specified by a single flow path Humphrey cycle. The performance of an ejector was discussed in terms of apparent entropy and mixed flow entropy. Through an ideal ejector, the apparent part of entropy increases due to the reduction in flow unsteadiness, but entropy of the mixed flow remains constant. The method is applied to a CFD simulation with a simple manifold for qualitative evaluation. The operation of the wave rotor constant volume combustion rig is experimentally examined. The rig has shown versatility of operation for wide range of conditions. Large pressure rise in the rotor channel and in a section of the exhaust duct are observed even with relatively large leakage gaps on the rotor. The simplified analysis indicated that inconsistent combustion is likely due to insufficient fuel near the ignition source. However, it is difficult to conclude its fuel distribution with the current setup. Additional measurement near the rotor interfaces and better fuel control are required for the future test.
AlTaan, S L; Mohammed, I; Said, D G; Dua, H S
2018-01-01
PurposeTo measure the pressure and volume of air required to create a big bubble (BB) in simulated deep anterior lamellar keratoplasty (DALK) in donor eyes and ascertain the bursting pressure of the BB.Patients and methodsTwenty-two human sclera-corneal discs were used. Air was injected into the corneal stroma to create a BB and the pressure measured by means of a pressure converter attached to the system via a side port. A special clamp was designed to prevent air leak from the periphery of the discs. The pressure at which air emerged in the corneal tissue; the bursting pressure measured after advancing the needle into the bubble cavity and injecting more air; the volume of air required to create a BB and the volume of the BB were ascertained.ResultsType-1 BB were achieved in 19 and type-2 BB in 3 eyes. The maximum pressure reached to create a BB was 96.25+/- 21.61 kpa; the mean type-1 intrabubble pressure was 10.16 +/- 3.65 kpa. The mean bursting pressure of a type-1 BB was 66.65 +/- 18.65 kpa, while that of a type-2 BB was 14.77 +/- 2.44 kpa. The volume of air required to create a type-1 BB was 0.54 ml and the volume of a type-1 BB was consistently 0.1 ml.ConclusionsDua's layer baring DALK can withstand high intraoperative pressures compared to Descemet's membrane baring DALK. The study suggests that it could be safe to undertake procedures such as DALK-triple with a type-1 BB but not with a type-2 BB.
NASA Astrophysics Data System (ADS)
Lubo, M.; Rooman, M.; Spindel, Ph.
1999-02-01
We investigate, in the framework of (2+1)-dimensional gravity, stationary rotationally symmetric gravitational sources of the perfect fluid type, embedded in a space of an arbitrary cosmological constant. We show that the matching conditions between the interior and exterior geometries imply restrictions on the physical parameters of the solutions. In particular, imposing finite sources and the absence of closed timelike curves privileges negative values of the cosmological constant, yielding exterior vacuum geometries of rotating black hole type. In the special case of static sources, we prove the complete integrability of the field equations and show that the sources' masses are bounded from above and, for a vanishing cosmological constant, generally equal to 1. We also discuss and illustrate the stationary configurations by explicitly solving the field equations for constant mass-energy densities. If the pressure vanishes, we recover as interior geometries Gödel-like metrics defined on causally well behaved domains, but with unphysical values of the mass to angular momentum ratio. The introduction of pressure in the sources cures the latter problem and leads to physically more relevant models.
Classical Renin-Angiotensin System in Kidney Physiology
Sparks, Matthew A.; Crowley, Steven D.; Gurley, Susan B.; Mirotsou, Maria; Coffman, Thomas M.
2014-01-01
The renin-angiotensin system has powerful effects in control of the blood pressure and sodium homeostasis. These actions are coordinated through integrated actions in the kidney, cardio-vascular system and the central nervous system. Along with its impact on blood pressure, the renin-angiotensin system also influences a range of processes from inflammation and immune responses to longevity. Here, we review the actions of the “classical” renin-angiotensin system, whereby the substrate protein angiotensinogen is processed in a two-step reaction by renin and angiotensin converting enzyme, resulting in the sequential generation of angiotensin I and angiotensin II, the major biologically active renin-angiotensin system peptide, which exerts its actions via type 1 and type 2 angiotensin receptors. In recent years, several new enzymes, peptides, and receptors related to the renin-angiotensin system have been identified, manifesting a complexity that was previously unappreciated. While the functions of these alternative pathways will be reviewed elsewhere in this journal, our focus here is on the physiological role of components of the “classical” renin-angiotensin system, with an emphasis on new developments and modern concepts. PMID:24944035
An Overview of NASA Efforts on Zero Boiloff Storage of Cryogenic Propellants
NASA Technical Reports Server (NTRS)
Hastings, Leon J.; Plachta, D. W.; Salerno, L.; Kittel, P.; Haynes, Davy (Technical Monitor)
2001-01-01
Future mission planning within NASA has increasingly motivated consideration of cryogenic propellant storage durations on the order of years as opposed to a few weeks or months. Furthermore, the advancement of cryocooler and passive insulation technologies in recent years has substantially improved the prospects for zero boiloff storage of cryogenics. Accordingly, a cooperative effort by NASA's Ames Research Center (ARC), Glenn Research Center (GRC), and Marshall Space Flight Center (MSFC) has been implemented to develop and demonstrate "zero boiloff" concepts for in-space storage of cryogenic propellants, particularly liquid hydrogen and oxygen. ARC is leading the development of flight-type cryocoolers, GRC the subsystem development and small scale testing, and MSFC the large scale and integrated system level testing. Thermal and fluid modeling involves a combined effort by the three Centers. Recent accomplishments include: 1) development of "zero boiloff" analytical modeling techniques for sizing the storage tankage, passive insulation, cryocooler, power source mass, and radiators; 2) an early subscale demonstration with liquid hydrogen 3) procurement of a flight-type 10 watt, 95 K pulse tube cryocooler for liquid oxygen storage and 4) assembly of a large-scale test article for an early demonstration of the integrated operation of passive insulation, destratification/pressure control, and cryocooler (commercial unit) subsystems to achieve zero boiloff storage of liquid hydrogen. Near term plans include the large-scale integrated system demonstration testing this summer, subsystem testing of the flight-type pulse-tube cryocooler with liquid nitrogen (oxygen simulant), and continued development of a flight-type liquid hydrogen pulse tube cryocooler.
Applications for fiber optic sensing in the upstream oil and gas industry
NASA Astrophysics Data System (ADS)
Baldwin, Chris S.
2015-05-01
Fiber optic sensing has been used in an increasing number of applications in the upstream oil and gas industry over the past 20 years. In some cases, fiber optic sensing is providing measurements where traditional measurement technologies could not. This paper will provide a general overview of these applications and describe how the use of fiber optic sensing is enabling these applications. Technologies such as Bragg gratings, distributed temperature and acoustic sensing, interferometric sensing, and Brillouin scattering will be discussed. Applications for optic sensing include a range of possibilities from a single pressure measurement point in the wellbore to multizone pressure and flow monitoring. Some applications make use of fully distributed measurements including thermal profiling of the well. Outside of the wellbore, fiber optic sensors are used in applications for flowline and pipeline monitoring and for riser integrity monitoring. Applications to be described in this paper include in-flow profiling, well integrity, production monitoring, and steam chamber growth. These applications will cover well types such as injectors, producers, hydraulic fracturing, and thermal recovery. Many of these applications use the measurements provided by fiber optic sensing to improve enhanced oil recovery operations. The growing use of fiber optic sensors is providing improved measurement capabilities leading to the generation of actionable data for enhanced production optimization. This not only increases the recovered amount of production fluids but can also enhance wellbore integrity and safety.
The properties of fast and slow oblique solitons in a magnetized plasma
NASA Astrophysics Data System (ADS)
McKenzie, J. F.; Doyle, T. B.
2002-01-01
This work builds on a recent treatment by McKenzie and Doyle [Phys. Plasmas 8, 4367 (2001)], on oblique solitons in a cold magnetized plasma, to include the effects of plasma thermal pressure. Conservation of total momentum in the direction of wave propagation immediately shows that if the flow is supersonic, compressive (rarefactive) changes in the magnetic pressure induce decelerations (accelerations) in the flow speed, whereas if the flow is subsonic, compressive (rarefactive) changes in the magnetic pressure induce accelerations (decelerations) in the flow speed. Such behavior is characteristic of a Bernoulli-type plasma momentum flux which exhibits a minimum at the plasma sonic point. The plasma energy flux (kinetic plus enthalpy) also shows similar Bernoulli-type behavior. This transonic effect is manifest in the spatial structure equation for the flow speed (in the direction of propagation) which shows that soliton structures may exist if the wave speed lies either (i) in the range between the fast and Alfven speeds or (ii) between the sound and slow mode speed. These conditions follow from the requirement that a defined, characteristic "soliton parameter" m exceeds unity. It is in this latter slow soliton regime that the effects of plasma pressure are most keenly felt. The equilibrium points of the structure equation define the center of the wave. The structure of both fast and slow solitons is elucidated through the properties of the energy integral function of the structure equation. In particular, the slow soliton, which owes its existence to plasma pressure, may have either a compressive or rarefactive nature, and exhibits a rich structure, which is revealed through the spatial structure of the longitudinal speed and its corresponding transverse velocity hodograph.
Mirabito, Katrina M; Hilliard, Lucinda M; Kett, Michelle M; Brown, Russell D; Booth, Sean C; Widdop, Robert E; Moritz, Karen M; Evans, Roger G; Denton, Kate M
2014-10-15
Sex hormones regulate the renin-angiotensin system. For example, estrogen enhances expression of the angiotensin type 2 receptor. We hypothesized that activation of the angiotensin type 2 receptor shifts the chronic pressure-natriuresis relationship leftward in females compared with males and that this effect is lost with age. Mean arterial pressure was measured by radiotelemetry in adult (4 mo old) and aged (14 mo old) wild-type and angiotensin type 2 receptor knockout male and female mice. Chronic pressure-natriuresis curves were constructed while mice were maintained on a normal-salt (0.26%) diet and following 6 days of high salt (5.0%) diet. Mean arterial pressure was lower in adult wild-type females than males (88 ± 1 and 97 ± 1 mmHg, respectively), a difference that was maintained with age, but was absent in adult knockout mice. In wild-type females, the chronic pressure-natriuresis relationship was shifted leftward compared with knockout females, an effect that was lost with age. In males, the chronic pressure-natriuresis relationship was not influenced by angiotensin type 2 receptor deficiency. Compared with age-matched females, the chronic pressure-natriuresis relationships in male mice were shifted rightward. Renal expression of the angiotensin type 2 receptor was fourfold greater in adult wild-type females than males. With age, the angiotensin type 2 receptor-to-angiotensin type 1 receptor balance was reduced in females. Conversely, in males, angiotensin receptor expression did not vary significantly with age. In conclusion, the angiotensin type 2 receptor modulates the chronic pressure-natriuresis relationship in an age- and sex-dependent manner. Copyright © 2014 the American Physiological Society.
Impacts of sodium-glucose co-transporter type 2 inhibitors on central blood pressure.
Takenaka, Tsuneo; Ohno, Yoichi; Suzuki, Hiromichi
2018-03-01
To assess the effects of sodium-glucose co-transporter type 2 inhibitors on central blood pressure, an important determinant of cardiovascular events. Canagliflozin, Empagliflozin or Luseogliflozin was given for 102 type 2 diabetic patients with hypertension and nephropathy. Central blood pressure was evaluated by radial tonometry. Clinical parameters were followed for 6 months. Three differing sodium-glucose co-transporter type 2 inhibitors similarly reduced brachial and central blood pressures, casual blood sugar, haemoglobin A1c, estimated glomerular filtration rate and albuminuria without significant changes in pulse rate and lipid profiles. Central systolic blood pressure was associated with the decreases in albuminuria by sodium-glucose co-transporter type 2 inhibitors. Comparable influences of various sodium-glucose co-transporter type 2 inhibitors on central blood pressure suggest class effects.
NASA Astrophysics Data System (ADS)
Rashid, A. A.; Sidek, A. A.; Suffian, S. A.; Daud, M. R. C.
2018-01-01
The idea of assimilating green supply chain is to integrate and establish environmental management into the supply chain practices. The study aims to explore how environmental management competitive pressure influences a SME company in Malaysia to incorporate green supply chain integration, which is an efficient platform to develop environmental innovation. This study further advances green supply chain management research in Malaysia by using the method of quantitative analysis to analyze the model developed which data will be collected based on a sample of SMEs in Malaysia in manufacturing sector. The model developed in this study illustrates how environmental management competitive pressure from main competitors affects three fundamental dimensions of green supply chain integration. The research findings suggest that environmental management competitive pressure is a vital driving force for a SME company to incorporate internal and external collaboration in developing green product innovation. From the analysis conducted, the study strongly demonstrated that the best way for a company to counteract competitor’s environmental management success is to first implement strong internal green product development process then move to incorporate external environmental management innovation between their suppliers and customers. The findings also show that internal integration of green product innovation fully mediates the relationship of environmental management competitive pressure and the external integration of green product innovation.
NASA Technical Reports Server (NTRS)
Melcher, John C.; Morehead, Robert L.; Atwell, Matthew J.; Hurlbert, Eric A.
2015-01-01
A liquid oxygen / liquid methane 2,000 lbf thruster was designed and tested in conjuction with a nozzle heat exchanger for cold helium pressurization. Cold helium pressurization systems offer significant spacecraft vehicle dry mass savings since the pressurant tank size can be reduced as the pressurant density is increased. A heat exchanger can be incorporated into the main engine design to provide expansion of the pressurant supply to the propellant tanks. In order to study the systems integration of a cold-helium pressurization system, a 2,000 lbf thruster with a nozzle heat exchanger was designed for integration into the Project Morpheus vehicle at NASA Johnson Space Center. The testing goals were to demonstrate helium loading and initial conditioning to low temperatures, high-pressure/low temperature storage, expansion through the main engine heat exchanger, and propellant tank injection/pressurization. The helium pressurant tank was an existing 19 inch diameter composite-overwrap tank, and the targert conditions were 4500 psi and -250 F, providing a 2:1 density advantage compared to room tempatrue storage. The thruster design uses like-on-like doublets in the injector pattern largely based on Project Morpheus main engine hertiage data, and the combustion chamber was designed for an ablative chamber. The heat exchanger was installed at the ablative nozzle exit plane. Stand-alone engine testing was conducted at NASA Stennis Space Center, including copper heat-sink chambers and highly-instrumented spoolpieces in order to study engine performance, stability, and wall heat flux. A one-dimensional thermal model of the integrated system was completed. System integration into the Project Morpheus vehicle is complete, and systems demonstrations will follow.
Yoo, Won-Gyu
2015-01-01
[Purpose] This study showed the effects of different computer typing speeds on acceleration and peak contact pressure of the fingertips during computer typing. [Subjects] Twenty-one male computer workers voluntarily consented to participate in this study. They consisted of 7 workers who could type 200-300 characteristics/minute, 7 workers who could type 300-400 characteristics/minute, and 7 workers who could type 400-500 chracteristics/minute. [Methods] This study was used to measure the acceleration and peak contact pressure of the fingertips for different typing speed groups using an accelerometer and CONFORMat system. [Results] The fingertip contact pressure was increased in the high typing speed group compared with the low and medium typing speed groups. The fingertip acceleration was increased in the high typing speed group compared with the low and medium typing speed groups. [Conclusion] The results of the present study indicate that a fast typing speed cause continuous pressure stress to be applied to the fingers, thereby creating pain in the fingers.
A High-Temperature Piezoresistive Pressure Sensor with an Integrated Signal-Conditioning Circuit.
Yao, Zong; Liang, Ting; Jia, Pinggang; Hong, Yingping; Qi, Lei; Lei, Cheng; Zhang, Bin; Xiong, Jijun
2016-06-18
This paper focuses on the design and fabrication of a high-temperature piezoresistive pressure sensor with an integrated signal-conditioning circuit, which consists of an encapsulated pressure-sensitive chip, a temperature compensation circuit and a signal-conditioning circuit. A silicon on insulation (SOI) material and a standard MEMS process are used in the pressure-sensitive chip fabrication, and high-temperature electronic components are adopted in the temperature-compensation and signal-conditioning circuits. The entire pressure sensor achieves a hermetic seal and can be operated long-term in the range of -50 °C to 220 °C. Unlike traditional pressure sensor output voltage ranges (in the dozens to hundreds of millivolts), the output voltage of this sensor is from 0 V to 5 V, which can significantly improve the signal-to-noise ratio and measurement accuracy in practical applications of long-term transmission based on experimental verification. Furthermore, because this flexible sensor's output voltage is adjustable, general follow-up pressure transmitter devices for voltage converters need not be used, which greatly reduces the cost of the test system. Thus, the proposed high-temperature piezoresistive pressure sensor with an integrated signal-conditioning circuit is expected to be highly applicable to pressure measurements in harsh environments.
On the extraction of pressure fields from PIV velocity measurements in turbines
NASA Astrophysics Data System (ADS)
Villegas, Arturo; Diez, Fancisco J.
2012-11-01
In this study, the pressure field for a water turbine is derived from particle image velocimetry (PIV) measurements. Measurements are performed in a recirculating water channel facility. The PIV measurements include calculating the tangential and axial forces applied to the turbine by solving the integral momentum equation around the airfoil. The results are compared with the forces obtained from the Blade Element Momentum theory (BEMT). Forces are calculated by using three different methods. In the first method, the pressure fields are obtained from PIV velocity fields by solving the Poisson equation. The boundary conditions are obtained from the Navier-Stokes momentum equations. In the second method, the pressure at the boundaries is determined by spatial integration of the pressure gradients along the boundaries. In the third method, applicable only to incompressible, inviscid, irrotational, and steady flow, the pressure is calculated using the Bernoulli equation. This approximated pressure is known to be accurate far from the airfoil and outside of the wake for steady flows. Additionally, the pressure is used to solve for the force from the integral momentum equation on the blade. From the three methods proposed to solve for pressure and forces from PIV measurements, the first one, which is solved by using the Poisson equation, provides the best match to the BEM theory calculations.
A High-Temperature Piezoresistive Pressure Sensor with an Integrated Signal-Conditioning Circuit
Yao, Zong; Liang, Ting; Jia, Pinggang; Hong, Yingping; Qi, Lei; Lei, Cheng; Zhang, Bin; Xiong, Jijun
2016-01-01
This paper focuses on the design and fabrication of a high-temperature piezoresistive pressure sensor with an integrated signal-conditioning circuit, which consists of an encapsulated pressure-sensitive chip, a temperature compensation circuit and a signal-conditioning circuit. A silicon on insulation (SOI) material and a standard MEMS process are used in the pressure-sensitive chip fabrication, and high-temperature electronic components are adopted in the temperature-compensation and signal-conditioning circuits. The entire pressure sensor achieves a hermetic seal and can be operated long-term in the range of −50 °C to 220 °C. Unlike traditional pressure sensor output voltage ranges (in the dozens to hundreds of millivolts), the output voltage of this sensor is from 0 V to 5 V, which can significantly improve the signal-to-noise ratio and measurement accuracy in practical applications of long-term transmission based on experimental verification. Furthermore, because this flexible sensor’s output voltage is adjustable, general follow-up pressure transmitter devices for voltage converters need not be used, which greatly reduces the cost of the test system. Thus, the proposed high-temperature piezoresistive pressure sensor with an integrated signal-conditioning circuit is expected to be highly applicable to pressure measurements in harsh environments. PMID:27322288
Silver metaphosphate glass wires inside silica fibers--a new approach for hybrid optical fibers.
Jain, Chhavi; Rodrigues, Bruno P; Wieduwilt, Torsten; Kobelke, Jens; Wondraczek, Lothar; Schmidt, Markus A
2016-02-22
Phosphate glasses represent promising candidates for next-generation photonic devices due to their unique characteristics, such as vastly tunable optical properties, and high rare earth solubility. Here we show that silver metaphosphate wires with bulk optical properties and diameters as small as 2 µm can be integrated into silica fibers using pressure-assisted melt filling. By analyzing two types of hybrid metaphosphate-silica fibers, we show that the filled metaphosphate glass has only negligible higher attenuation and a refractive index that is identical to the bulk material. The presented results pave the way towards new fiber-type optical devices relying on metaphosphate glasses, which are promising materials for applications in nonlinear optics, sensing and spectral filtering.
1989-07-31
facility awaits integration in the soon-to-be funded DOE 36 project, Robert Martinez has been using it to develop a method to evaluate surface stresses...explained as resulting from a pressure- dependent effective mass, m*, and we suggested that this was evidence for r - x 0 mixing. However, simple models of...between near Q i 2.6A’-. The overall shape of this type of data, measured over 10 orders of magnitude, places severe constraints on any possible model for
Instrumented urethral catheter and its ex vivo validation in a sheep urethra
NASA Astrophysics Data System (ADS)
Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, Serdar
2017-03-01
This paper designs and fabricates an instrumented catheter for instantaneous measurement of distributed urethral pressure profiles. Since the catheter enables a new type of urological measurement, a process for accurate ex vivo validation of the catheter is developed. A flexible sensor strip is first fabricated with nine pressure sensors and integrated electronic pads for an associated sensor IC chip. The flexible sensor strip and associated IC chip are assembled on a 7 Fr Foley catheter. A sheep bladder and urethra are extracted and used in an ex vivo set up for verification of the developed instrumented catheter. The bladder-urethra are suspended in a test rig and pressure cuffs placed to apply known static and dynamic pressures around the urethra. A significant challenge in the performance of the sensor system is the presence of parasitics that introduce large bias and drift errors in the capacitive sensor signals. An algorithm based on use of reference parasitic transducers is used to compensate for the parasitics. Extensive experimental results verify that the developed compensation method works effectively. Results on pressure variation profiles circumferentially around the urethra and longitudinally along the urethra are presented. The developed instrumented catheter will be useful in improved urodynamics to more accurately diagnose the source of urinary incontinence in patients.
Blood Pressure Regulation: Every Adaptation is an Integration?
Joyner, Michael J.; Limberg, Jacqueline K.
2013-01-01
This focused review serves to explore relevant issues in regard to blood pressure regulation and by doing so, provides the initial stimulus paper for the Thematic Review series “Blood Pressure Regulation” to be published in the European Journal of Applied Physiology over the coming months. In this introduction, we highlight how variable normal blood pressure can be and challenge the reader to take another look at some key concepts related to blood pressure regulation. We point out that there is frequently an underappreciated balance between peripheral vasodilation and systemic blood pressure regulation and ask the question: Are changes in blood pressure, in effect, reasonable and integrated adaptations to the physiological challenge at hand? We conclude with the idea that blood pressure regulatory systems are both flexible and redundant; ensuring a wide variety of activities associated with life can be accompanied by a perfusion pressure that can serve multiple masters. PMID:23558925
Edwards, Helen E; Chang, Anne M; Gibb, Michelle; Finlayson, Kathleen J; Parker, Christina; O'Reilly, Maria; McDowell, Jan; Shuter, Patricia
2017-12-01
To evaluate the implementation of the Champions for Skin Integrity model on facilitating uptake of evidence-based wound management and improving skin integrity in residents of aged care facilities. The incidence of skin tears, pressure injuries and leg ulcers increases with age, and such wounds can be a serious issue in aged care facilities. Older adults are not only at higher risk for wounds related to chronic disease but also injuries related to falls and manual handling requirements. A longitudinal, pre-post design. The Champions for Skin Integrity model was developed using evidence-based strategies for transfer of evidence into practice. Data were collected before and six months after implementation of the model. Data on wound management and skin integrity were obtained from two random samples of residents (n = 200 pre; n = 201 post) from seven aged care facilities. A staff survey was also undertaken (n = 126 pre; n = 143 post) of experience, knowledge and evidence-based wound management. Descriptive statistics were calculated for all variables. Where relevant, chi-square for independence or t-tests were used to identify differences between the pre-/postdata. There was a significant decrease in the number of residents with a wound of any type (54% pre vs 43% post, χ 2 4·2, p = 0·041), as well as a significant reduction in specific wound types, for example pressure injuries (24% pre vs 10% post, χ 2 14·1, p < 0·001), following implementation of the model. An increase in implementation of evidence-based wound management and prevention strategies was observed in the postimplementation sample in comparison with the preimplementation sample. This included use of limb protectors and/or protective clothing 6% pre vs 20% post (χ 2 17·0, p < 0·001) and use of an emollient or soap alternative for bathing residents (50% pre vs 74% post, χ 2 13·9, p = 0·001). Implementation of the model in this sample fostered an increase in implementation of evidence-based wound management and prevention strategies, which was associated with a decrease in the prevalence and severity of wounds. This study suggests the Champions for Skin Integrity model has the potential to improve uptake of evidence-based wound management and improve skin integrity for older adults. © 2017 John Wiley & Sons Ltd.
"Zero-Mass" Noninvasive Pressure Transducers
NASA Technical Reports Server (NTRS)
Hartley, Frank T.
2009-01-01
Extremely lightweight, compact, noninvasive, rugged, relatively inexpensive strain-gauge transducers have been developed for use in measuring pressures of fluids in tubes. These gauges were originally intended for measuring pressures of spacecraft-propulsion fluids, but they are also attractive for use in numerous terrestrial applications especially those involving fluids that are extremely chemically reactive, fluids that must be isolated for hygienic purposes, fluids that must be allowed to flow without obstruction, and fluid-containing tubes exposed to severe environments. A basic pressure transducer of this type comprises one or more pair(s) of thin-film strain gauges integral with a tube that contains the fluid of interest. Following established strain-gauge practice, the gauges in each pair are connected into opposite arms of a Wheatstone bridge (see figure). Typically, each pressure transducer includes one pair (the active pair) of strain gauges for measuring the hoop stress proportional to the pressure of the fluid in the tube and another pair (the dummy pair) of strain gauges that are nominally unstrained: The dummy gauges are mounted on a substrate that is made of the same material as that of the tube. The substrate is welded to the tube at only one spot so that stresses and strains are not coupled from the tube into the substrate. The dummy strain gauges measure neutral strains (basically, strains associated with thermal expansion), so that the neutral-strain contribution can be subtracted out of the final gauge reading.
NASA Astrophysics Data System (ADS)
Guitouni, Ahmed; Chaieb, Iheb; Rhouma, Amir Ben; Fredj, Nabil Ben
2016-11-01
Fluid application in grinding is getting attention as higher stock removal rates, higher surface integrity and longer wheel life are required. It is necessary to define proper conditions of application for meeting high productivity goals by lowering the specific grinding energy and reducing the temperature of the contact zone. The present study investigated the capacity of the jet pressure of a spot nozzle to improve the wear of a CBN wheel when grinding the AISI 690 superalloy. Grinding experiments were conducted with an emulsion-type cooling fluid delivered at pressure ranging from 0.1 to 4 MPa. Results show that the maximum stock removal, reached at 4 MPa, is 5 times the stock removal obtained at 0.1 MPa, while the grinding ratio at 4 MPa is 8 times that at 0.1 MPa, and there is a critical pressure ( P c) around 1.5 MPa corresponding to the minimum specific grinding energy. Scanning electron microscopy of the grain tips showed that the wear mechanism shifts from breaking and dislodgment at low jet pressure to micro-fracture resulting in continuous self-sharpening of the abrasive grains. By lubricating at jet pressure close to P c, there is less thermal damage due to plowing and sliding and the resulting lower loading of the abrasive grains favors the micro-fracture of grains and thus a longer wheel life.
Energy Conversion Alternatives Study (ECAS)
NASA Technical Reports Server (NTRS)
1977-01-01
ECAS compared various advanced energy conversion systems that can use coal or coal-derived fuels for baseload electric power generation. It was conducted in two phases. Phase 1 consisted of parametric studies. From these results, 11 concepts were selected for further study in Phase 2. For each of the Phase 2 systems and a common set of ground rules, performance, cost, environmental intrusion, and natural resource requirements were estimated. In addition, the contractors defined the state of the associated technology, identified the advances required, prepared preliminary research and development plans, and assessed other factors that would affect the implementation of each type of powerplant. The systems studied in Phase 2 include steam systems with atmospheric- and pressurized-fluidized-bed boilers; combined cycle gas turbine/steam systems with integrated gasifiers or fired by a semiclean, coal derived fuel; a potassium/steam system with a pressurized-fluidized-bed boiler; a closed-cycle gas turbine/organic system with a high-temperature, atmospheric-fluidized-bed furnace; a direct-coal-fired, open- cycle magnetohydrodynamic/steam system; and a molten-carbonate fuel cell/steam system with an integrated gasifier. The sensitivity of the results to changes in the ground rules and the impact of uncertainties in capital cost estimates were also examined.
Increased in-shoe lateral plantar pressures with chronic ankle instability.
Schmidt, Heather; Sauer, Lindsay D; Lee, Sae Yong; Saliba, Susan; Hertel, Jay
2011-11-01
Previous plantar pressure research found increased loads and slower loading response on the lateral aspect of the foot during gait with chronic ankle instability compared to healthy controls. The studies had subjects walking barefoot over a pressure mat and results have not been confirmed with an in-shoe plantar pressure system. Our purpose was to report in-shoe plantar pressure measures for chronic ankle instability subjects compared to healthy controls. Forty-nine subjects volunteered (25 healthy controls, 24 chronic ankle instability) for this case-control study. Subjects jogged continuously on a treadmill at 2.68 m/s (6.0 mph) while three trials of ten consecutive steps were recorded. Peak pressure, time-to-peak pressure, pressure-time integral, maximum force, time-to-maximum force, and force-time integral were assessed in nine regions of the foot with the Pedar-x in-shoe plantar pressure system (Novel, Munich, Germany). Chronic ankle instability subjects demonstrated a slower loading response in the lateral rearfoot indicated by a longer time-to-peak pressure (16.5% +/- 10.1, p = 0.001) and time-to-maximum force (16.8% +/- 11.3, p = 0.001) compared to controls (6.5% +/- 3.7 and 6.6% +/- 5.5, respectively). In the lateral midfoot, ankle instability subjects demonstrated significantly greater maximum force (318.8 N +/- 174.5, p = 0.008) and peak pressure (211.4 kPa +/- 57.7, p = 0.008) compared to controls (191.6 N +/- 74.5 and 161.3 kPa +/- 54.7). Additionally, ankle instability subjects demonstrated significantly higher force-time integral (44.1 N/s +/- 27.3, p = 0.005) and pressure-time integral (35.0 kPa/s +/- 12.0, p = 0.005) compared to controls (23.3 N/s +/- 10.9 and 24.5 kPa/s +/- 9.5). In the lateral forefoot, ankle instability subjects demonstrated significantly greater maximum force (239.9N +/- 81.2, p = 0.004), force-time integral (37.0 N/s +/- 14.9, p = 0.003), and time-to-peak pressure (51.1% +/- 10.9, p = 0.007) compared to controls (170.6 N +/- 49.3, 24.3 N/s +/- 7.2 and 43.8% +/- 4.3). Using an in-shoe plantar pressure system, chronic ankle instability subjects had greater plantar pressures and forces in the lateral foot compared to controls during jogging. These findings may have implications in the etiology and treatment of chronic ankle instability.
Eaton, William P.; Staple, Bevan D.; Smith, James H.
2000-01-01
A microelectromechanical (MEM) capacitance pressure sensor integrated with electronic circuitry on a common substrate and a method for forming such a device are disclosed. The MEM capacitance pressure sensor includes a capacitance pressure sensor formed at least partially in a cavity etched below the surface of a silicon substrate and adjacent circuitry (CMOS, BiCMOS, or bipolar circuitry) formed on the substrate. By forming the capacitance pressure sensor in the cavity, the substrate can be planarized (e.g. by chemical-mechanical polishing) so that a standard set of integrated circuit processing steps can be used to form the electronic circuitry (e.g. using an aluminum or aluminum-alloy interconnect metallization).
Zuo, Lian; Wan, Ting; Xu, Xiahong; Liu, Feifeng; Li, Changsong; Li, Ying; Zhang, Yue; Zhang, Jing; Bao, Huan; Li, Gang
2016-01-01
We examined the relationship between an early spontaneous type V blood pressure fluctuation and the post-thrombolysis prognosis of patients with acute cerebral infarction. Patients were admitted consecutively. All patients were categorized into the type V blood pressure fluctuation group or non-type V blood pressure group. Their blood pressure was monitored before thrombolysis and until 6 h after thrombolysis. Baseline data and clinical outcomes were compared. Of 170 patients, 43 (25.2%) had an early type V blood pressure fluctuation. The National Institute of Health Stroke Scale (NIHSS) score before thrombolysis and 24 h after thrombolysis, and the modified Rankin scale score at 90 days differed significantly between the two groups (P < 0.05). Multiple logistic regression analysis showed that an unfavorable prognosis at 3 months was associated with the NIHSS score before thrombolysis (P = 0.000) but probably not with this blood pressure fluctuation (P = 0.058). An early spontaneous type V blood pressure fluctuation is common in patients with acute cerebral infarction who received venous thrombolysis, especially if they have a higher NIHSS score before thrombolysis. The type V blood pressure fluctuation may not influence patients’ prognosis; however, this needs to be confirmed in future trials. PMID:27278121
Low power integrated pumping and valving arrays for microfluidic systems
Krulevitch, Peter A [Pleasanton, CA; Benett, William J [Livermore, CA; Rose, Klint A [Livermore, CA; Hamilton, Julie [Tracy, CA; Maghribi, Mariam [Davis, CA
2006-04-11
Low power integrated pumping and valving arrays which provide a revolutionary approach for performing pumping and valving approach for performing pumping and valving operations in microfabricated fluidic systems for applications such as medical diagnostic microchips. Traditional methods rely on external, large pressure sources that defeat the advantages of miniaturization. Previously demonstrated microfabrication devices are power and voltage intensive, only function at sufficient pressure to be broadly applicable. This approach integrates a lower power, high-pressure source with a polymer, ceramic, or metal plug enclosed within a microchannel, analogous to a microsyringe. When the pressure source is activated, the polymer plug slides within the microchannel, pumping the fluid on the opposite side of the plug without allowing fluid to leak around the plug. The plugs also can serve as microvalves.
Gonzalez, Maria E; Anthon, Gordon E; Barrett, Diane M
2010-09-01
Two different analytical methods were evaluated for their capacity to provide quantitative information on onion cell membrane permeability and integrity after high pressure and thermal processing and to study the impact of these processing treatments on cell compartmentalization and texture quality. To determine changes in cell membrane permeability and/or integrity the methodologies utilized were: (1) measurement of a biochemical product, pyruvate, formed as a result of membrane permeabilization followed by enzymatic activity and (2) leakage of electrolytes into solution. These results were compared to previously determined methods that quantified cell viability and ¹H-NMR T(2) of onions. These methods allowed for the monitoring of changes in the plasma and tonoplast membranes after high pressure or thermal processing. High pressure treatments consisted of 5 min holding times at 50, 100, 200, 300, or 600 MPa. Thermal treatments consisted of 30 min water bath exposure to 40, 50, 60, 70, or 90 °C. There was strong agreement between the methods in the determination of the ranges of high pressure and temperature that induce changes in the integrity of the plasma and tonoplast membranes. Membrane rupture could clearly be identified at 300 MPa and above in high pressure treatments and at 60 °C and above in the thermal treatments. Membrane destabilization effects could already be visualized following the 200 MPa and 50 °C treatments. The texture of onions was influenced by the state of the membranes and was abruptly modified once membrane integrity was lost. In this study, we used chemical, biochemical, and histological techniques to obtain information on cell membrane permeability and onion tissue integrity after high pressure and thermal processing. Because there was strong agreement between the various methods used, it is possible to implement something relatively simple, such as ion leakage, into routine quality assurance measurements to determine the severity of preservation methods and the shelf life of processed vegetables.
Development of a Pressure Switched Microfluidic Cell Sorter
NASA Astrophysics Data System (ADS)
Ozbay, Baris; Jones, Alex; Gibson, Emily
2009-10-01
Lab on a chip technology allows for the replacement of traditional cell sorters with microfluidic devices which can be produced less expensively and are more compact. Additionally, the compact nature of microfluidic cell sorters may lead to the realization of their application in point-of-care medical devices. Though techniques have been demonstrated previously for sorting in microfluidic devices with optical or electro-osmotic switching, both of these techniques are expensive and more difficult to implement than pressure switching. This microfluidic cell sorter design also allows for easy integration with optical spectroscopy for identification of cell type. Our current microfluidic device was fabricated with polydimethylsiloxane (PDMS), a polymer that houses the channels, which is then chemically bonded to a glass slide. The flow of fluid through the device is controlled by pressure controllers, and the switching of the cells is accomplished with the use of a high performance pressure controller interfaced with a computer. The cells are fed through the channels with the use of hydrodynamic focusing techniques. Once the experimental setup is fully functional the objective will be to determine switching rates, explore techniques to optimize these rates, and experiment with sorting of other biomolecules including DNA.
NASA Astrophysics Data System (ADS)
Roshanghias, Ali; Bardong, Jochen; Pulko, Jozef; Binder, Alfred
2018-04-01
Advanced optical measurement techniques are always of interest for the characterization of engineered surfaces. When pressure or temperature modules are also incorporated, these techniques will turn into robust and versatile methodologies for various applications such as performance monitoring of devices in service conditions. However, some microelectromechanical systems (MEMS) and MOEMS devices require performance monitoring at their final stage, i.e. enclosed or packaged. That necessitates measurements through a protective liquid, plastic, or glass, whereas the conventional objective lenses are not designed for such media. Correspondingly, in the current study, the development and tailoring of a 3D interferometer as a means for measuring the topography of reflective surfaces under transmissive media is sought. For topography measurements through glass, water and oil, compensation glass plates were designed and incorporated into the Michelson type interferometer objectives. Moreover, a customized chamber set-up featuring an optical access for the observation of the topographical changes at increasing pressure and temperature conditions was constructed and integrated into the apparatus. Conclusively, the in situ monitoring of the elastic deformation of sensing microstructures inside MEMS packages was achieved. These measurements were performed at a defined pressure (0–100 bar) and temperature (25 °C–180 °C).
Cundiff, Jenny M; Matthews, Karen A
2018-05-01
In adults, greater social integration is associated with reduced risk of cardiovascular disease, including hypertension. Social integration earlier in life may be similarly associated with cardiovascular risk. Using a longitudinal sample of 267 Black and White men, we examined whether greater social integration with peers during childhood and adolescence, assessed by parent report, prospectively predicts lower blood pressure and body mass index two decades later in adulthood and whether these effects differ by race, given well-documented racial disparities in hypertension. Boys who were reported by their parents to be more socially integrated with peers evidenced lower blood pressure and body mass index in adulthood, and this effect was not accounted for by body mass index in childhood, childhood socioeconomic status, childhood hostility, childhood physical health, extraversion measured in adolescence, or concurrent adult self-reports of social integration. Results did not differ by race, but analyses were not powered to detect interactions of small effect size.
46 CFR 58.30-25 - Accumulators.
Code of Federal Regulations, 2010 CFR
2010-10-01
... pressure vessel in which energy is stored under high pressure in the form of a gas or a gas and hydraulic... pressures not exceeding the maximum allowable working pressures. When an accumulator forms an integral part...
Sustainable Procurement: Integrating Classroom Learning with University Sustainability Programs
ERIC Educational Resources Information Center
Goldschmidt, Kyle; Harrison, Terry; Holtry, Matthew; Reeh, Jeremy
2013-01-01
Organizations are facing increased pressure from various stakeholders to address issues of sustainability, resulting in a growing demand for sustainability education and training. Procurement groups remain the key drivers of many sustainability-related strategies, placing pressure on universities to integrate sustainability concepts into the…
Effect of spinal needle characteristics on measurement of spinal canal opening pressure.
Bellamkonda, Venkatesh R; Wright, Thomas C; Lohse, Christine M; Keaveny, Virginia R; Funk, Eric C; Olson, Michael D; Laack, Torrey A
2017-05-01
A wide variety of spinal needles are used in clinical practice. Little is currently known regarding the impact of needle length, gauge, and tip type on the needle's ability to measure spinal canal opening pressure. This study aimed to investigate the relationship between these factors and the opening-pressure measurement or time to obtain an opening pressure. Thirteen distinct spinal needles, chosen to isolate the effects of length, gauge, and needle-point type, were prospectively tested on a lumbar puncture simulator. The key outcomes were the opening-pressure measurement and the time required to obtain that measure. Pressures were recorded at 10-s intervals until 3 consecutive, identical readings were observed. Time to measure opening pressure increased with increasing spinal needle length, increasing gauge, and the Quincke-type (cutting) point (P<0.001 for all). The time to measurement ranged from 30s to 530s, yet all needle types were able to obtain a consistent opening pressure measure. Although opening pressure estimates are unlikely to vary markedly by needle type, the time required to obtain the measurement increased with increasing needle length and gauge and with Quincke-type needles. Copyright © 2017 Elsevier Inc. All rights reserved.
Energy efficient engine preliminary design and integration study
NASA Technical Reports Server (NTRS)
Gray, D. E.
1978-01-01
The technology and configurational requirements of an all new 1990's energy efficient turbofan engine having a twin spool arrangement with a directly coupled fan and low-pressure turbine, a mixed exhaust nacelle, and a high 38.6:1 overall pressure ratio were studied. Major advanced technology design features required to provide the overall benefits were a high pressure ratio compression system, a thermally actuated advanced clearance control system, lightweight shroudless fan blades, a low maintenance cost one-stage high pressure turbine, a short efficient mixer and structurally integrated engine and nacelle. A conceptual design analysis was followed by integration and performance analyses of geared and direct-drive fan engines with separate or mixed exhaust nacelles to refine previously designed engine cycles. Preliminary design and more detailed engine-aircraft integration analysis were then conducted on the more promising configurations. Engine and aircraft sizing, fuel burned, and airframe noise studies on projected 1990's domestic and international aircraft produced sufficient definition of configurational and advanced technology requirements to allow immediate initiation of component technology development.
Surface Integrity of Inconel 718 by Ball Burnishing
NASA Astrophysics Data System (ADS)
Sequera, A.; Fu, C. H.; Guo, Y. B.; Wei, X. T.
2014-09-01
Inconel 718 has wide applications in manufacturing mechanical components such as turbine blades, turbocharger rotors, and nuclear reactors. Since these components are subject to harsh environments such as high temperature, pressure, and corrosion, it is critical to improve the functionality to prevent catastrophic failure due to fatigue or corrosion. Ball burnishing as a low plastic deformation process is a promising technique to enhance surface integrity for increasing component fatigue and corrosion resistance in service. This study focuses on the experimental study on surface integrity of burnished Inconel 718. The effects of burnishing ball size and pressure on surface integrity factors such as surface topography, roughness, and hardness are investigated. The burnished surfaces are smoother than the as-machined ones. Surface hardness after burnishing is higher than the as-machined surfaces, but become stable over a certain burnishing pressure. There exists an optimal process space of ball sized and burnishing pressure for surface finish. In addition, surface hardness after burnishing is higher than the as-machined surfaces, which is confirmed by statistical analysis.
NASA Astrophysics Data System (ADS)
Sun, Yimin; Verschuur, Eric; van Borselen, Roald
2018-03-01
The Rayleigh integral solution of the acoustic Helmholtz equation in a homogeneous medium can only be applied when the integral surface is a planar surface, while in reality almost all surfaces where pressure waves are measured exhibit some curvature. In this paper we derive a theoretically rigorous way of building propagation operators for pressure waves on an arbitrarily curved surface. Our theory is still based upon the Rayleigh integral, but it resorts to matrix inversion to overcome the limitations faced by the Rayleigh integral. Three examples are used to demonstrate the correctness of our theory - propagation of pressure waves acquired on an arbitrarily curved surface to a planar surface, on an arbitrarily curved surface to another arbitrarily curved surface, and on a spherical cap to a planar surface, and results agree well with the analytical solutions. The generalization of our method for particle velocities and the calculation cost of our method are also discussed.
The epistemic integrity of NASA practices in the Space Shuttle Program.
De Winter, Jan; Kosolosky, Laszlo
2013-01-01
This article presents an account of epistemic integrity and uses it to demonstrate that the epistemic integrity of different kinds of practices in NASA's Space Shuttle Program was limited. We focus on the following kinds of practices: (1) research by working engineers, (2) review by middle-level managers, and (3) communication with the public. We argue that the epistemic integrity of these practices was undermined by production pressure at NASA, i.e., the pressure to launch an unreasonable amount of flights per year. Finally, our findings are used to develop some potential strategies to protect epistemic integrity in aerospace science.
NASA Technical Reports Server (NTRS)
Mushotzky, R. F.; Serlemitsos, P. J.; Smith, B. W.; Boldt, E. A.; Holt, S. S.
1978-01-01
OSO-8 X-ray spectra from 2 to 20 keV were analyzed for 26 clusters of galaxies. Temperature, emission integrals, iron abundances, and low energy absorption measurements are given. Eight clusters have positive iron emission line detections at the 90% confidence level, and all twenty cluster spectra are consistent with Fe/H=0.000014 by number with the possible exception of Virgo. Physical correlations between X-ray spectral parameters and other cluster properties are examined. It is found that: (1) the X-ray temperature is approximately proportional to the square of the velocity dispersion of the galaxies; (2) the emission integral and therefore the bolometric X-ray luminosity is a strong function of the X-ray temperature; (3) the X-ray temperature and emission integral are better correlated with cluster central galaxy density than with richness; (4) temperature and emission integral are separately correlated with Rood-Sastry type; and (5) the fraction of galaxies which are spirals is correlated with the observed ram pressure in the cluster core.
ERIC Educational Resources Information Center
Nyasulu, Frazier; Barlag, Rebecca
2010-01-01
The reaction kinetics of the iodide-catalyzed decomposition of [subscript 2]O[subscript 2] using the integrated-rate method is described. The method is based on the measurement of the total gas pressure using a datalogger and pressure sensor. This is a modification of a previously reported experiment based on the initial-rate approach. (Contains 2…
Exercise excess pressure and exercise-induced albuminuria in patients with type 2 diabetes mellitus.
Climie, Rachel E D; Srikanth, Velandai; Keith, Laura J; Davies, Justin E; Sharman, James E
2015-05-01
Exercise-induced albuminuria is common in patients with type 2 diabetes mellitus (T2DM) in response to maximal exercise, but the response to light-moderate exercise is unclear. Patients with T2DM have abnormal central hemodynamics and greater propensity for exercise hypertension. This study sought to determine the relationship between light-moderate exercise central hemodynamics (including aortic reservoir and excess pressure) and exercise-induced albuminuria. Thirty-nine T2DM (62 ± 9 yr; 49% male) and 39 nondiabetic controls (53 ± 9 yr; 51% male) were examined at rest and during 20 min of light-moderate cycle exercise (30 W; 50 revolutions/min). Albuminuria was assessed by the albumin-creatinine ratio (ACR) at rest and 30 min postexercise. Hemodynamics recorded included brachial and central blood pressure (BP), aortic stiffness, augmented pressure (AP), aortic reservoir pressure, and excess pressure integral (Pexcess). There was no difference in ACR between groups before exercise (P > 0.05). Exercise induced a significant rise in ACR in T2DM but not controls (1.73 ± 1.43 vs. 0.53 ± 1.0 mg/mol, P = 0.002). All central hemodynamic variables were significantly higher during exercise in T2DM (i.e., Pexcess, systolic BP and AP; P < 0.01 all). In T2DM (but not controls), exercise Pexcess was associated with postexercise ACR (r = 0.51, P = 0.002), and this relationship was independent of age, sex, body mass index, heart rate, aortic stiffness, antihypertensive medication, and ambulatory daytime systolic BP (β = 0.003, P = 0.003). Light-moderate exercise induced a significant rise in ACR in T2DM, and this was independently associated with Pexcess, a potential marker of vascular dysfunction. These novel findings suggest that Pexcess could be important for appropriate renal function in T2DM. Copyright © 2015 the American Physiological Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josse, Florent; Lefebvre, Yannick; Todeschini, Patrick
2006-07-01
Assessing the structural integrity of a nuclear Reactor Pressure Vessel (RPV) subjected to pressurized-thermal-shock (PTS) transients is extremely important to safety. In addition to conventional deterministic calculations to confirm RPV integrity, Electricite de France (EDF) carries out probabilistic analyses. Probabilistic analyses are interesting because some key variables, albeit conventionally taken at conservative values, can be modeled more accurately through statistical variability. One variable which significantly affects RPV structural integrity assessment is cleavage fracture initiation toughness. The reference fracture toughness method currently in use at EDF is the RCCM and ASME Code lower-bound K{sub IC} based on the indexing parameter RT{submore » NDT}. However, in order to quantify the toughness scatter for probabilistic analyses, the master curve method is being analyzed at present. Furthermore, the master curve method is a direct means of evaluating fracture toughness based on K{sub JC} data. In the framework of the master curve investigation undertaken by EDF, this article deals with the following two statistical items: building a master curve from an extract of a fracture toughness dataset (from the European project 'Unified Reference Fracture Toughness Design curves for RPV Steels') and controlling statistical uncertainty for both mono-temperature and multi-temperature tests. Concerning the first point, master curve temperature dependence is empirical in nature. To determine the 'original' master curve, Wallin postulated that a unified description of fracture toughness temperature dependence for ferritic steels is possible, and used a large number of data corresponding to nuclear-grade pressure vessel steels and welds. Our working hypothesis is that some ferritic steels may behave in slightly different ways. Therefore we focused exclusively on the basic french reactor vessel metal of types A508 Class 3 and A 533 grade B Class 1, taking the sampling level and direction into account as well as the test specimen type. As for the second point, the emphasis is placed on the uncertainties in applying the master curve approach. For a toughness dataset based on different specimens of a single product, application of the master curve methodology requires the statistical estimation of one parameter: the reference temperature T{sub 0}. Because of the limited number of specimens, estimation of this temperature is uncertain. The ASTM standard provides a rough evaluation of this statistical uncertainty through an approximate confidence interval. In this paper, a thorough study is carried out to build more meaningful confidence intervals (for both mono-temperature and multi-temperature tests). These results ensure better control over uncertainty, and allow rigorous analysis of the impact of its influencing factors: the number of specimens and the temperatures at which they have been tested. (authors)« less
Stassen, Oscar M. J. A.; ter Huurne, Fleur M.; Boareto, Marcelo; Sahlgren, Cecilia M.
2018-01-01
Hemodynamic forces and Notch signaling are both known as key regulators of arterial remodeling and homeostasis. However, how these two factors integrate in vascular morphogenesis and homeostasis is unclear. Here, we combined experiments and modeling to evaluate the impact of the integration of mechanics and Notch signaling on vascular homeostasis. Vascular smooth muscle cells (VSMCs) were cyclically stretched on flexible membranes, as quantified via video tracking, demonstrating that the expression of Jagged1, Notch3, and target genes was down-regulated with strain. The data were incorporated in a computational framework of Notch signaling in the vascular wall, where the mechanical load was defined by the vascular geometry and blood pressure. Upon increasing wall thickness, the model predicted a switch-type behavior of the Notch signaling state with a steep transition of synthetic toward contractile VSMCs at a certain transition thickness. These thicknesses varied per investigated arterial location and were in good agreement with human anatomical data, thereby suggesting that the Notch response to hemodynamics plays an important role in the establishment of vascular homeostasis. PMID:29610298
Orion ECLSS/Suit System - Ambient Pressure Integrated Suit Test
NASA Technical Reports Server (NTRS)
Barido, Richard A.
2012-01-01
The Ambient Pressure Integrated Suit Test (APIST) phase of the integrated system testing of the Orion Vehicle Atmosphere Revitalization System (ARS) technology was conducted for the Multipurpose Crew Vehicle (MPCV) Program within the National Aeronautics and Space Administration (NASA) Exploration Systems Mission Directorate. Crew and Thermal Systems Division performed this test in the eleven-foot human-rated vacuum chamber at the NASA Johnson Space Center. This testing is the first phase of suit loop testing to demonstrate the viability of the Environmental Control and Life Support System (ECLSS) being developed for Orion. APIST is the first in a series, which will consist of testing development hardware including the Carbon dioxide and Moisture Removal Amine Swing-bed (CAMRAS) and the air revitalization loop fan with human test subjects in pressure suits at varying suit pressures. Follow-on testing, to be conducted in 2013, will utilize the CAMRAS and a development regulator with human test subjects in pressure suits at varying cabin and suit pressures. This paper will discuss the results and findings of APIST and will also discuss future testing.
Wu, Chueh-Yu; Lu, Jau-Ching; Liu, Man-Chi; Tung, Yi-Chung
2012-10-21
Microfluidic technology plays an essential role in various lab on a chip devices due to its desired advantages. An automated microfluidic system integrated with actuators and sensors can further achieve better controllability. A number of microfluidic actuation schemes have been well developed. In contrast, most of the existing sensing methods still heavily rely on optical observations and external transducers, which have drawbacks including: costly instrumentation, professional operation, tedious interfacing, and difficulties of scaling up and further signal processing. This paper reports the concept of electrofluidic circuits - electrical circuits which are constructed using ionic liquid (IL)-filled fluidic channels. The developed electrofluidic circuits can be fabricated using a well-developed multi-layer soft lithography (MSL) process with polydimethylsiloxane (PDMS) microfluidic channels. Electrofluidic circuits allow seamless integration of pressure sensors with analog and digital operation functions into microfluidic systems and provide electrical readouts for further signal processing. In the experiments, the analog operation device is constructed based on electrofluidic Wheatstone bridge circuits with electrical outputs of the addition and subtraction results of the applied pressures. The digital operation (AND, OR, and XOR) devices are constructed using the electrofluidic pressure controlled switches, and output electrical signals of digital operations of the applied pressures. The experimental results demonstrate the designed functions for analog and digital operations of applied pressures are successfully achieved using the developed electrofluidic circuits, making them promising to develop integrated microfluidic systems with capabilities of precise pressure monitoring and further feedback control for advanced lab on a chip applications.
NASA Astrophysics Data System (ADS)
Hufenbach, W.; Gude, M.; Czulak, A.; Kretschmann, Martin
2014-04-01
Increasing economic, political and ecological pressure leads to steadily rising percentage of modern processing and manufacturing processes for fibre reinforced polymers in industrial batch production. Component weights beneath a level achievable by classic construction materials, which lead to a reduced energy and cost balance during product lifetime, justify the higher fabrication costs. However, complex quality control and failure prediction slow down the substitution by composite materials. High-resolution fibre-optic sensors (FOS), due their low diameter, high measuring point density and simple handling, show a high applicability potential for an automated sensor-integration in manufacturing processes, and therefore the online monitoring of composite products manufactured in industrial scale. Integrated sensors can be used to monitor manufacturing processes, part tests as well as the component structure during product life cycle, which simplifies allows quality control during production and the optimization of single manufacturing processes.[1;2] Furthermore, detailed failure analyses lead to a enhanced understanding of failure processes appearing in composite materials. This leads to a lower wastrel number and products of a higher value and longer product life cycle, whereby costs, material and energy are saved. This work shows an automation approach for FOS-integration in the braiding process. For that purpose a braiding wheel has been supplemented with an appliance for automatic sensor application, which has been used to manufacture preforms of high-pressure composite vessels with FOS-networks integrated between the fibre layers. All following manufacturing processes (vacuum infiltration, curing) and component tests (quasi-static pressure test, programmed delamination) were monitored with the help of the integrated sensor networks. Keywords: SHM, high-pressure composite vessel, braiding, automated sensor integration, pressure test, quality control, optic-fibre sensors, Rayleigh, Luna Technologies
Treatment of Post-SCI Hypotension
2018-02-15
Spinal Cord Injury; Autonomic Dysreflexia; Orthostatic Hypotension; Baroreceptor Integrity; Sympathetic Integrity; Vagal Integrity; Hypotension; Cerebral Blood Flow; Blood Pressure; Venous Occlusion Plethysmography
Integrated high pressure manifold for thermoplastic microfluidic devices
NASA Astrophysics Data System (ADS)
Aghvami, S. Ali; Fraden, Seth
2017-11-01
We introduce an integrated tubing manifold for thermoplastic microfluidic chips that tolerates high pressure. In contrast to easy tubing in PDMS microfluidic devices, tube connection has been challenging for plastic microfluidics. Our integrated manifold connection tolerates 360 psi while conventional PDMS connections fail at 50 psi. Important design considerations are incorporation of a quick-connect, leak-free and high-pressure manifold for the inlets and outlets on the lid and registration marks that allow the precise alignment of the inlets and outlets. In our method, devices are comprised of two molded pieces joined together to create a sealed device. The first piece contains the microfluidic features and the second contains the inlet and outlet manifold, a frame for rigidity and a viewing window. The mold for the lid with integrated manifold is CNC milled from aluminium. A cone shape PDMS component which acts as an O-ring, seals the connection between molded manifold and tubing. The lid piece with integrated inlet and outlets will be a standard piece and can be used for different chips and designs. Sealing the thermoplastic device is accomplished by timed immersion of the lid in a mixture of volatile and non-volatile solvents followed by application of heat and pressure.
Wong, Nichol M. L.; Ma, Ernie Po-Wing; Lee, Tatia M. C.
2017-01-01
Hypertension is a risk factor for cognitive impairment in older age. However, evidence of the neural basis of the relationship between the deterioration of cognitive function and elevated blood pressure is sparse. Based on previous research, we speculate that variations in brain connectivity are closely related to elevated blood pressure even before the onset of clinical conditions and apparent cognitive decline in individuals over 60 years of age. Forty cognitively healthy adults were recruited. Each received a blood pressure test before and after the cognitive assessment in various domains. Diffusion tensor imaging (DTI) and resting-state functional magnetic resonance imaging (rsfMRI) data were collected. Our findings confirm that elevated blood pressure is associated with brain connectivity variations in cognitively healthy individuals. The integrity of the splenium of the corpus callosum is closely related to individual differences in systolic blood pressure. In particular, elevated systolic blood pressure is related to resting-state ventral attention network (VAN) and information processing speed. Serial mediation analyses have further revealed that lower integrity of the splenium statistically predicts elevated systolic blood pressure, which in turn predicts weakened functional connectivity (FC) within the VAN and eventually poorer processing speed. The current study sheds light on how neural correlates are involved in the impact of elevated blood pressure on cognitive functioning. PMID:28484386
NASA Astrophysics Data System (ADS)
Lieberman, Robert A.
Various papers on chemical, biochemical, and environmental fiber sensors are presented. Individual topics addressed include: fiber optic pressure sensor for combustion monitoring and control, viologen-based fiber optic oxygen sensors, renewable-reagent fiber optic sensor for ocean pCO2, transition metal complexes as indicators for a fiber optic oxygen sensor, fiber optic pH measurements using azo indicators, simple reversible fiber optic chemical sensors using solvatochromic dyes, totally integrated optical measuring sensors, integrated optic biosensor for environmental monitoring, radiation dosimetry using planar waveguide sensors, optical and piezoelectric analysis of polymer films for chemical sensor characterization, source polarization effects in an optical fiber fluorosensor, lens-type refractometer for on-line chemical analysis, fiber optic hydrocarbon sensor system, chemical sensors for environmental monitoring, optical fibers for liquid-crystal sensing and logic devices, suitability of single-mode fluoride fibers for evanescent-wave sensing, integrated modules for fiber optic sensors, optoelectronic sensors based on narrowband A3B5 alloys, fiber Bragg grating chemical sensor.
Fracture Testing of Integral Stiffened Structure
NASA Technical Reports Server (NTRS)
Newman, John A.; Smith, Stephen W.; Piascik, Robert S.; Dawicke, David S.; Johnston, William M.; Willard, Scott A.
2008-01-01
Laboratory testing was conducted to evaluate safety concerns for integrally-stiffened tanks that were found to have developed cracks during pressurization testing. Cracks occurred at fastener holes where additional stiffeners were attached to the integrally-stiffened tank structure. Tests were conducted to obtain material properties and to reproduce the crack morphologies that were observed in service to help determine if the tanks are safe for operation. Reproducing the cracking modes observed during pressurization testing required a complex loading state involving both a tensile load in the integrally-stiffened structure and a pin-load at a fastener hole.
This study presents the integrated volume method for estimating saturation pressure and enthalpy of vaporization of a whole aerosol distribution. We measure the change of total volume of an aerosol distribution between a reference state and several heated states, with the heating...
Accurate pressure gradient calculations in hydrostatic atmospheric models
NASA Technical Reports Server (NTRS)
Carroll, John J.; Mendez-Nunez, Luis R.; Tanrikulu, Saffet
1987-01-01
A method for the accurate calculation of the horizontal pressure gradient acceleration in hydrostatic atmospheric models is presented which is especially useful in situations where the isothermal surfaces are not parallel to the vertical coordinate surfaces. The present method is shown to be exact if the potential temperature lapse rate is constant between the vertical pressure integration limits. The technique is applied to both the integration of the hydrostatic equation and the computation of the slope correction term in the horizontal pressure gradient. A fixed vertical grid and a dynamic grid defined by the significant levels in the vertical temperature distribution are employed.
Sun, Jianqin; Wang, Yanfang; Chen, Xiafei; Chen, Yanqiu; Feng, Ying; Zhang, Xinyi; Pan, Yiru; Hu, Ting; Xu, Jianhua; Du, Luyuan; Zhou, Wei; Zhao, Huiping; Riley, Rosemary E; Mustad, Vikkie A
2008-01-01
This study evaluated a structured and integrated intervention program on diabetes management in individuals with type 2 diabetes in Shanghai, China. Men and women with type 2 diabetes and body mass index > 23 kg/m2 were randomized into a 24-week, prospective, randomized clinical trial. The Reference Group (n=50) received diabetes education including diet and physical activity instruction only; the Intervention Group (n=100) received more intensive intervention, including diabetes education with frequent blood glucose monitoring, nutritional counseling, meal plans with diabetes-specific nutritional meal replacement, and weekly progress updates with study staff. Major study assessments were obtained at baseline, and after 12 and/or 24 weeks of intervention. The Intervention Group improved fasting blood glucose, insulin, systolic and diastolic blood pressures compared to Reference Group ( p <0.05). Importantly, HbA1c was lower ( p <0.001) in the Intervention Group at 12 weeks (-0.6 +/- 0.1%) and 24 weeks (-0.8 +/- 0.1%). Weight loss was modest, but significant differences were observed between groups ( p <0.05). Weight change from baseline after 12 and 24 weeks was -2.8 +/- 0.2% and -3.7 +/- 0.3%, respectively, in the Intervention Group vs -1.8 +/- 0.4% and -2.5 +/- 0.4% in the Reference Group. Additionally, waist and hip circumferences and waist:hip ratio decreased in the Intervention compared to the Reference Group ( p <0.05). In conclusion, this study demonstrates that Chinese men and women with type 2 diabetes following an integrated intervention program including diabetes education, frequent blood glucose monitoring and daily use of a diabetes-specific meal replacement, can achieve significant improvements in glycemic control and markers of cardiovascular health.
The Usability of a Pressure-Indicating Film to Measure the Teat Load Caused by a Collapsing Liner
Demba, Susanne; Elsholz, Sabrina; Ammon, Christian; Rose-Meierhöfer, Sandra
2016-01-01
Prevention of damage to the teat and mastitis requires determination of the teat load caused by a collapsing liner. The aim of this study was to test a pressure-indicating film designed to measure the pressure between a collapsing liner and artificial teats. The Ultra Super Low and the Extreme Low pressure-indicating films were tested on two types of artificial teat. The experiments were performed with a conventional milking cluster equipped with round silicone liners. For each teat and film type, 30 repetitions were performed. Each repetition was performed with a new piece of film. Kruskal-Wallis tests were performed to detect differences between the pressure values for the different teats. The area of regions where pressure-indication color developed was calculated to determine the most suitable film type. Both film types measured the pressure applied to both artificial teats by the teat cup liner. Thus, the pressure-indicating films can be used to measure the pressure between a collapsing liner and an artificial teat. Based on the results of the present investigation, a pressure-indicating film with the measurement ranges of both film types combined would be an optimal tool to measure the overall pressure between an artificial teat and a collapsing liner. PMID:27690033
Shin, Seung Kak; Kim, Kyoung Oh; Kim, Eui Joo; Kim, Su Young; Kim, Jung Ho; Kim, Yoon Jae; Chung, Jun-Won; Kwon, Kwang An; Park, Dong Kyun
2017-01-01
Guillain-Barre syndrome (GBS)-associated achalasia is a very rare disease of uncertain cause. We report the case of a patient diagnosed with GBS-associated type I achalasia who was successfully treated with peroral endoscopic myotomy (POEM). A 30-year-old man who was diagnosed with GBS 3 mo before was referred to our department with dysphagia and meal-related regurgitation. The results of esophagography, endoscopy, and high-resolution manometry (HRM) revealed type I achalasia. POEM that utilized a submucosal tunneling technique was performed to treat the GBS-associated type I achalasia. After POEM, smooth passage of a contrast agent into the stomach was shown in follow-up esophagography, and follow-up HRM revealed a decrease in the mean integrated relaxation pressure 22.9 mmHg to 9.6 mmHg. The patient remained without dysphagia for 7 mo, even though the patient’s neurological problems were not fully resolved. POEM may be a safe and effective treatment for GBS-associated type I achalasia. PMID:28223738
Acoustic emission monitoring of composite containment systems
NASA Astrophysics Data System (ADS)
Maguire, John R.
2011-07-01
This paper considers two different types of composite containment system, and two different types of acoustic emission (AE) monitoring approach. The first system is a composite reinforced pressure vessel (CRPV) which is monitored both during construction and in-service using a broadband modal acoustic emission (MAE) technique. The second system is a membrane cargo containment system which is monitored using both a global as well as a local AE technique. For the CRPV, the damage assessment is concerned mainly with the integrity of the composite outer layer at the construction stage, and possible fatigue cracking of the inner steel liner at the in-service stage. For the membrane tank, the damage assessment is concerned with locating and quantifying any abnormal porosities that might develop in-service. By comparing and contrasting the different types of structural system and different monitoring approaches inferences are drawn as to what role AE monitoring could take in the damage assessment of other types of composite containment system. (Detailed technical data have not been included, due to client confidentiality constraints.)
Novel high-pressure phase of ZrO{sub 2}: An ab initio prediction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durandurdu, Murat, E-mail: murat.durandurdu@agu.edu.tr
2015-10-15
The high-pressure behavior of the orthorhombic cotunnite type ZrO{sub 2} is explored using an ab initio constant pressure technique. For the first time, a novel hexagonal phase (Ni{sub 2}In type) within P6{sub 3}/mmc symmetry is predicted through the simulation. The Ni{sub 2}In type crystal is the densest high-pressure phase of ZrO{sub 2} proposed so far and has not been observed in other metal dioxides at high pressure before. The phase transformation is accompanied by a small volume drop and likely to occur around 380 GPa in experiment. - Graphical abstract: Post-cotunnite Ni{sub 2}In type hexagonal phase forms in zirconia atmore » high pressure. - Highlights: • A post-cotunnite phase is predicted for ZrO{sub 2} through an ab initio simulation. • Cotunnite ZrO{sub 2} adopts the Ni{sub 2}In type structure at high pressure. • The Ni{sub 2}In type structure is the densest high-pressure phase of ZrO{sub 2} proposed so far. • The preferred mechanism in ZrO{sub 2} differs from the other metal dioxides.« less
Jeong, Y J; Oh, T I; Woo, E J; Kim, K J
2017-07-01
Recently, highly flexible and soft pressure distribution imaging sensor is in great demand for tactile sensing, gait analysis, ubiquitous life-care based on activity recognition, and therapeutics. In this study, we integrate the piezo-capacitive and piezo-electric nanowebs with the conductive fabric sheets for detecting static and dynamic pressure distributions on a large sensing area. Electrical impedance tomography (EIT) and electric source imaging are applied for reconstructing pressure distribution images from measured current-voltage data on the boundary of the hybrid fabric sensor. We evaluated the piezo-capacitive nanoweb sensor, piezo-electric nanoweb sensor, and hybrid fabric sensor. The results show the feasibility of static and dynamic pressure distribution imaging from the boundary measurements of the fabric sensors.
NASA Astrophysics Data System (ADS)
Moreto, Jose; Liu, Xiaofeng
2017-11-01
The accuracy of the Rotating Parallel Ray omnidirectional integration for pressure reconstruction from the measured pressure gradient (Liu et al., AIAA paper 2016-1049) is evaluated against both the Circular Virtual Boundary omnidirectional integration (Liu and Katz, 2006 and 2013) and the conventional Poisson equation approach. Dirichlet condition at one boundary point and Neumann condition at all other boundary points are applied to the Poisson solver. A direct numerical simulation database of isotropic turbulence flow (JHTDB), with a homogeneously distributed random noise added to the entire field of DNS pressure gradient, is used to assess the performance of the methods. The random noise, generated by the Matlab function Rand, has a magnitude varying randomly within the range of +/-40% of the maximum DNS pressure gradient. To account for the effect of the noise distribution pattern on the reconstructed pressure accuracy, a total of 1000 different noise distributions achieved by using different random number seeds are involved in the evaluation. Final results after averaging the 1000 realizations show that the error of the reconstructed pressure normalized by the DNS pressure variation range is 0.15 +/-0.07 for the Poisson equation approach, 0.028 +/-0.003 for the Circular Virtual Boundary method and 0.027 +/-0.003 for the Rotating Parallel Ray method, indicating the robustness of the Rotating Parallel Ray method in pressure reconstruction. Sponsor: The San Diego State University UGP program.
NASA Technical Reports Server (NTRS)
Desmarais, R. N.; Rowe, W. S.
1984-01-01
For the design of active controls to stabilize flight vehicles, which requires the use of unsteady aerodynamics that are valid for arbitrary complex frequencies, algorithms are derived for evaluating the nonelementary part of the kernel of the integral equation that relates unsteady pressure to downwash. This part of the kernel is separated into an infinite limit integral that is evaluated using Bessel and Struve functions and into a finite limit integral that is expanded in series and integrated termwise in closed form. The developed series expansions gave reliable answers for all complex reduced frequencies and executed faster than exponential approximations for many pressure stations.
van Hateren, Kornelis J J; Landman, Gijs W D; Groenier, Klaas H; Bilo, Henk J G; Kleefstra, Nanne
2015-04-01
There is limited evidence with respect to the between-group effects of various angiotensin receptor blockers (ARBs) on blood pressure and albuminuria in patients with type 2 diabetes mellitus. Therefore, we aimed to investigate the effects of differing ARBs on systolic blood pressure (SBP) and the albumin-creatinine ratio after 1 year in a large cohort of patients with type 2 diabetes mellitus. In 2007, 24 940 primary care patients with type 2 diabetes mellitus participated in the Zwolle Outpatient Diabetes project Integrating Available Care (ZODIAC) study, a prospective observational cohort study. Patients were included in the current study if they were prescribed an ARB in 2007 and if 1-year follow-up data were available. The final study population comprised 3610 patients. Multivariate mixed-model analyses were performed to estimate effects of the various ARBs on SBP and albuminuria. Stratified subgroup analyses were performed according to baseline hypertension and albuminuria. SBP decreased in all groups, the largest decrease being observed in the group receiving telmisartan. No significant or relevant changes over time were observed among groups for SBP and albuminuria. In the subgroup (n=1225) of normotensive patients, telmisartan was associated with a larger decrease in SBP after 1 year compared to other ARBs, without different effects on the albumin-creatinine ratio. We observed no differences in effects on SBP and the albumin-creatinine ratio among differing ARBs in patients with type 2 diabetes mellitus. Copyright © 2015 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Zhenhai; Wang, Qinglin; Ma, Yanzhang
Nanoscale materials exhibit properties that are quite distinct from those of bulk materials because of their size restricted nature. Here, we investigated the high-pressure structural stability of cubic (C-type) nano-Eu2O3 using in situ synchrotron X-ray diffraction (XRD), Raman and luminescence spectroscopy, and impedance spectra techniques. Our high-pressure XRD experimental results revealed a pressure-induced structural phase transition in nano-Eu2O3 from the C-type phase (space group: Ia-3) to a hexagonal phase (A-type, space group: P-3m1). Our reported transition pressure (9.3 GPa) in nano-Eu2O3 is higher than that of the corresponding bulk-Eu2O3 (5.0 GPa), which is contrary to the preceding reported experimental result.more » After pressure release, the A-type phase of Eu2O3 transforms into a new monoclinic phase (B-type, space group: C2/m). Compared with bulk-Eu2O3, C-type and A-type nano-Eu2O3 exhibits a larger bulk modulus. Our Raman and luminescence findings and XRD data provide consistent evidence of a pressure-induced structural phase transition in nano-Eu2O3. To our knowledge, we have performed the first high-pressure impedance spectra investigation on nano-Eu2O3 to examine the effect of the structural phase transition on its transport properties. We propose that the resistance inflection exhibited at ~12 GPa results from the phase boundary between the C-type and A-type phases. Besides, we summarized and discussed the structural evolution process by the phase diagram of lanthanide sesquioxides (Ln2O3) under high pressure.« less
Innovative Pressure Sensor Platform and Its Integration with an End-User Application
Flores-Caballero, Antonio; Copaci, Dorin; Blanco, María Dolores; Moreno, Luis; Herrán, Jaime; Fernández, Iván; Ochoteco, Estíbaliz; Cabañero, German; Grande, Hans
2014-01-01
This paper describes the fully integration of an innovative and low-cost pressure sensor sheet based on a bendable and printed electronics technology. All integration stages are covered, from most low-level functional system, like physical analog sensor data acquisition, followed by embedded data processing, to end user interactive visual application. Data acquisition embedded software and hardware was developed using a Rapid Control Prototyping (RCP). Finally, after first electronic prototype successful testing, a Taylor-made electronics was developed, reducing electronics volume to 3.5 cm × 6 cm × 2 cm with a maximum power consumption of 765 mW for both electronics and pressure sensor sheet. PMID:24922455
You, Wen-Hua; Han, Cui-Min; Fang, Long-Xiang; Du, Dao-Lin
2016-01-01
Many notorious invasive plants are clonal, spreading mainly by vegetative propagules. Propagule pressure (the number of propagules) may affect the establishment, growth, and thus invasion success of these clonal plants, and such effects may also depend on habitat conditions. To understand how propagule pressure, habitat conditions and clonal integration affect the establishment and growth of the invasive clonal plants, an 8-week greenhouse with an invasive clonal plant, Alternanthera philoxeroides was conducted. High (five fragments) or low (one fragment) propagule pressure was established either in bare soil (open habitat) or dense native vegetation of Jussiaea repens (vegetative habitat), with the stolon connections either severed from or connected to the relatively older ramets. High propagule pressure greatly increased the establishment and growth of A. philoxeroides, especially when it grew in vegetative habitats. Surprisingly, high propagule pressure significantly reduced the growth of individual plants of A. philoxeroides in open habitats, whereas it did not affect the individual growth in vegetative habitats. A shift in the intraspecific interaction on A. philoxeroides from competition in open habitats to facilitation in vegetative habitats may be the main reason. Moreover, clonal integration significantly improved the growth of A. philoxeroides only in open habitats, especially with low propagule pressure, whereas it had no effects on the growth and competitive ability of A. philoxeroides in vegetative habitats, suggesting that clonal integration may be of most important for A. philoxeroides to explore new open space and spread. These findings suggest that propagule pressure may be crucial for the invasion success of A. philoxeroides, and such an effect also depends on habitat conditions.
Effect of Wrist Posture on Carpal Tunnel Pressure while Typing
Rempel, David M.; Keir, Peter J.; Bach, Joel M.
2009-01-01
Long weekly hours of keyboard use may lead to or aggravate carpal tunnel syndrome. The effects of typing on fluid pressure in the carpal tunnel, a possible mediator of carpal tunnel syndrome, are unknown. Twenty healthy subjects participated in a laboratory study to investigate the effects of typing at different wrist postures on carpal tunnel pressure of the right hand. Changes in wrist flexion/extension angle (p = 0.01) and radial/ulnar deviation angle (p = 0.03) independently altered carpal tunnel pressure; wrist deviations in extension or radial deviation were associated with an increase in pressure. The activity of typing independently elevated carpal tunnel pressure (p= 0.001) relative to the static hand held in the same posture. This information can guide the design and use of keyboards and workstations in order to minimize carpal tunnel pressure while typing. The findings may also be useful to clinicians and ergonomists in the management of patients with carpal tunnel syndrome who use a keyboard. PMID:18383144
Space Environmental Effects on Thermal Control Coatings
NASA Technical Reports Server (NTRS)
OBrien, Susan K.; Workman, Gary L.
1997-01-01
The study of long term near ultra-violet (NUV) effects in a vacuum atmosphere, is a crucial element for space applications. NUV radiation causes significant changes in the reflectance of many coatings and types of materials. An ultra high vacuum NUV system was assembled in order to investigate various coatings and materials in this hostile environment. The vacuum is an ion pump that maintains a minimum vacuum in the mid 10(exp -9) range. The system has a base pressure of 10(exp -9) torr and this base pressure is maintained with the ion pump. The NUV exposure was maintained at 2-3 suns which allows accelerated NUV exposure without overheating the samples. The goal of this test was to maintain an intensity of 3.4 x 10(exp -2) Watts/cm(exp 2) which equals 2.9 NUV suns. An NUV sun is defined as 1.16 Watts/cm(exp 2) integrated over wavelength of 200-400 nanometers.
NASA Astrophysics Data System (ADS)
Omrani, Elahe; Hasani, Hossein; Dibajian, Sayed Houssain
2018-02-01
Textile composites of 3D integrated spacer configurations have been recently focused by several researchers all over the world. In the present study, newly-designed tubular composites reinforced with 3D spacer weft knitted fabrics were considered and the effects of their structural parameters on some applicable mechanical properties were investigated. For this purpose, two different samples of 3D spacer weft knitted textile types in tubular form were produced on an electronic flat knitting machine, using glass/nylon hybrid yarns. Thermoset tubular-shaped composite parts were manufactured via vacuum infusion molding process using epoxy resin. The mechanical properties of the produced knitted composites in term of external static and internal hydrostatic pressures were evaluated. Resistance of the produced composites against the external static and internal hydrostatic pressures was numerically simulated using multi-scale modeling method. The finding revealed that there is acceptable correlation between experimental and theoretical results.
Modeling of Plasma Pressure Effects on ELM Suppression With RMP in DIII-D
NASA Astrophysics Data System (ADS)
Orlov, D. M.; Moyer, R. A.; Mordijck, S.; Evans, T. E.; Osborne, T. H.; Snyder, P. B.; Unterberg, E. A.; Fenstermacher, M. E.
2009-11-01
Resonant magnetic perturbations (RMPs) are used to control the pedestal pressure gradient in both low and high (ν3^*) DIII-D plasmas. In this work we have analyzed several discharges with different levels of triangularity, different neutral beam injection power levels, and with, βN ranging from 1.5 to 2.3. The field line integration code TRIP3D was used to model the magnetic perturbation in ELMing and ELM suppressed phases during the RMP pulse. The results of this modeling showed very little effect of βN on the structure of the vacuum magnetic field during ELM suppression using n=3 RMPs. Kinetic equilibrium reconstructions showed a decrease in bootstrap current during RMP. Linear peeling-ballooning stability analysis performed with the ELITE code suggested that the ELMs, which persist during RMP, i.e. ELMing still is observed, are not Type I ELMs. Identification of these Dα spikes is an ongoing work.
Supersonic investigation of two dimensional hypersonic exhaust nozzles
NASA Technical Reports Server (NTRS)
Carboni, Jeanne D.; Shyne, Rickey J.; Leavitt, Laurence D.; Taylor, John G.; Lamb, Milton
1992-01-01
An experimental investigation was conducted in the NASA Lewis 10 x 10 ft supersonic Wind Tunnel to determine the performance characteristics of 2D hypersonic exhaust nozzles/afterbodies at low supersonic conditions. Generally, this type of application requires a single expansion ramp nozzle (SERN) that is highly integrated with the airframe of the hypersonic vehicle. At design conditions (hypersonic speeds), the nozzle generally exhibits acceptable performance. At off-design conditions (transonic to mid-supersonic speeds), nozzle performance of a fixed geometry configuration is generally poor. Various 2-D nozzle configurations were tested at off-design conditions from Mach 2.0 to 3.5. Performance data is presented at nozzle pressure ratios from 1 to 35. Jet exhaust was simulated with high-pressure air. To study performance of different geometries, nozzle configurations were varied by interchanging the following model parts: internal upstream contour, expansion ramp, sidewalls, and cowl.
NASA Astrophysics Data System (ADS)
Jang, Munseon; Yun, Kwang-Seok
2017-12-01
In this paper, we presents a MEMS pressure sensor integrated with a readout circuit on a chip for an on-chip signal processing. The capacitive pressure sensor is formed on a CMOS chip by using a post-CMOS MEMS processes. The proposed device consists of a sensing capacitor that is square in shape, a reference capacitor and a readout circuitry based on a switched-capacitor scheme to detect capacitance change at various environmental pressures. The readout circuit was implemented by using a commercial 0.35 μm CMOS process with 2 polysilicon and 4 metal layers. Then, the pressure sensor was formed by wet etching of metal 2 layer through via hole structures. Experimental results show that the MEMS pressure sensor has a sensitivity of 11 mV/100 kPa at the pressure range of 100-400 kPa.
Integrated-fin gasket for palm cubic-anvil high pressure apparatus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, J.-G.; Beijing National Laboratory for Condensed Matter Physics and Institute of Physics, Chinese Academy of Sciences, Beijing 100190; Matsubayashi, K.
2014-09-15
We described an integrated-fin gasket technique for the palm cubic-anvil apparatus specialized for the high-pressure and low-temperature measurements. By using such a gasket made from the semi-sintered MgO ceramics and the tungsten-carbide anvils of 2.5 mm square top, we successfully generate pressures over 16 GPa at both room and cryogenic temperatures down to 0.5 K. We observed a pressure self-increment for this specific configuration and further characterized the thermally induced pressure variation by monitoring the antiferromagnetic transition temperature of chromium up to 12 GPa. In addition to enlarge the pressure capacity, such a modified gasket also improves greatly the survivingmore » rate of electrical leads hanging the sample inside a Teflon capsule filled with the liquid pressure-transmitting medium. These improvements should be attributed to the reduced extrusion of gasket materials during the initial compression.« less
Finite element analysis and experiment on high pressure apparatus with split cylinder
NASA Astrophysics Data System (ADS)
Zhao, Liang; Li, Mingzhe; Yang, Yunfei; Wang, Bolong; Li, Yi
2017-07-01
Ultra-high pressure belt-type die was designed with a large sample volume prism cavity and a split cylinder which was divided into eight segments to eliminate circumferential stress. The cylinder of this type die has no cambered surface on inner wall, and the inner hole is a hexagonal prism-type cavity. The divided bodies squeeze with each other, providing the massive support and lateral support effect of the cylinder. Simulation results indicate that the split cylinder with the prism cavity possesses much smaller stress and more uniform stress distribution. The split cylinder with the prism cavity has been shown to bear larger compressive stresses in radial, circumferential and axial directions due to its structure, and tungsten carbide is most effective in pure compression so this type cylinder could bear higher pressure. Experimental results prove that the high pressure apparatus with a prism-type cavity could bear higher pressure. The apparatus with a prism cavity could bear 52.2% more pressure than the belt-type die.
Comparison of nine methods to estimate ear-canal stimulus levels
Souza, Natalie N.; Dhar, Sumitrajit; Neely, Stephen T.; Siegel, Jonathan H.
2014-01-01
The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion depth. The remaining five quantities were derived from the ear-canal pressure and the Thévenin-equivalent source characteristics of the probe: Forward pressure, initial forward pressure, the pressure transmitted into the middle ear, eardrum sound pressure estimated by summing the magnitudes of the forward and reverse pressure (integrated pressure) and absorbed power. Two sets of behavioral thresholds were measured in 26 subjects from 0.125 to 20 kHz, with the probe inserted at relatively deep and shallow positions in the ear canal. The greatest dependence on insertion depth was for transmitted pressure and absorbed power. The measures with the least dependence on insertion depth throughout the frequency range (best performance) included the depth-compensated simulator, eardrum, forward, and integrated pressures. Among these, forward pressure is advantageous because it quantifies stimulus phase. PMID:25324079
Shared or Integrated: Which Type of Integration is More Effective Improves Students’ Creativity?
NASA Astrophysics Data System (ADS)
Mariyam, M.; Kaniawati, I.; Sriyati, S.
2017-09-01
Integrated science learning has various types of integration. This study aims to apply shared and integrated type of integration with project based learning (PjBL) model to improve students’ creativity on waste recycling theme. The research method used is a quasi experiment with the matching-only pre test-post test design. The samples of this study are 108 students consisting of 36 students (experiment class 1st), 35 students (experiment class 2nd) and 37 students (control class 3rd) at one of Junior High School in Tanggamus, Lampung. The results show that there is difference of creativity improvement in the class applied by PjBL model with shared type of integration, integrated type of integration and without any integration in waste recycling theme. Class applied by PjBL model with shared type of integration has the higher creativity improvement than the PjBL model with integrated type of integration and without any integration. Integrated science learning using shared type only combines 2 lessons, hence an intact concept is resulted. So, PjBL model with shared type of integration more effective improves students’ creativity than integrated type.
Wigle, E D; Auger, P; Marquis, Y
1966-10-15
Two types of intraventricular pressure differences within the left ventricle of man are described. The first is encountered in cases of muscular (or fibrous) subaortic stenosis, in which the outflow tract pressure distal to the stenosis (and proximal to the aortic valve) is low, whereas all pressures recorded in the left ventricle proximal to the stenosis, including that just inside the mitral valve (the initial inflow tract pressure) are high.The second type of intraventricular pressure difference may be recorded in patients without muscular subaortic stenosis when a heart catheter is advanced to the left ventricular wall in such a manner that it becomes imbedded or entrapped by cardiac muscle in systole. Such an entrapped catheter records a high intraventricular pressure that is believed to reflect intramyocardial tissue pressure, which normally exceeds intracavitary pressure. In such cases the initial inflow tract pressure is not high and is precisely equal to the outflow tract systolic pressure, i.e. both are recording intracavity pressure. This type of intramyocardial to intracavitary pressure difference may also be encountered in the left ventricle of dogs.The recent suggestion that intraventricular pressure differences in the left ventricle of cases of muscular subaortic stenosis are due to catheter entrapment by cardiac muscle is refuted by using the initial inflow tract pressure as the means of differentiation between the two types of intraventricular pressure differences outlined.
Effects of Bloom-Forming Algae on Fouling of Integrated Membrane Systems in Seawater Desalination
ERIC Educational Resources Information Center
Ladner, David Allen
2009-01-01
Combining low- and high-pressure membranes into an integrated membrane system is an effective treatment strategy for seawater desalination. Low-pressure microfiltration (MF) and ultrafiltration (UF) membranes remove particulate material, colloids, and high-molecular-weight organics leaving a relatively foulant-free salt solution for treatment by…
Integrating Sustainability into Management Education: A Dean's Perspective
ERIC Educational Resources Information Center
Walck, Christa
2009-01-01
The integration of sustainability and environmental ethics into management education has improved in the past decade. This is partly a response to external pressure, as societal concerns about sustainability grow and businesses have made greater efforts to green their processes and products. But it is also a response to internal pressure from…
30 CFR 250.427 - What are the requirements for pressure integrity tests?
Code of Federal Regulations, 2012 CFR
2012-07-01
..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Casing and Cementing Requirements § 250.427 What are the requirements for... setting depth. You must conduct each pressure integrity test after drilling at least 10 feet but no more...
30 CFR 250.427 - What are the requirements for pressure integrity tests?
Code of Federal Regulations, 2014 CFR
2014-07-01
..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Casing and Cementing Requirements § 250.427 What are the requirements for... setting depth. You must conduct each pressure integrity test after drilling at least 10 feet but no more...
30 CFR 250.427 - What are the requirements for pressure integrity tests?
Code of Federal Regulations, 2013 CFR
2013-07-01
..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Casing and Cementing Requirements § 250.427 What are the requirements for... setting depth. You must conduct each pressure integrity test after drilling at least 10 feet but no more...
30 CFR 250.427 - What are the requirements for pressure integrity tests?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Casing and Cementing Requirements § 250.427 What are the... planned casing setting depth. You must conduct each pressure integrity test after drilling at least 10...
Improvement of a sensor unit for wrist blood pressure monitoring system
NASA Astrophysics Data System (ADS)
Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik
2007-12-01
A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.
Szúcs, G; Tóth, I; Bráth, E; Gyáni, K; Miko, I
2001-08-01
We have good results with telescopic anastomosis technique in partial oesophagectomies and gastrectomies. As we could not find data about the healing process of telescopic anastomoses so we started experimenting. Inside pressure tolerance was examined immediately after performing anastomoses by measuring the bursting pressure using the organs of pigs slaughtered in the meat industry. Both oesophago-gastrostomies and oesophago-jejunostomies were performed with telescopic, single layer interrupted, single layer continuous, double layer interrupted and double layer continuous-interrupted technique, 9 of each anastomosis. A series of oesophago-jejunostomies were performed with EEA stapler. 99 anastomoses of 11 types were investigated. We found, that the inner pressure tolerance of telescopic oesophago-gastrostomy is better than any other single layer type variant. On the other hand the double layer type variants have much better pressure tolerance than the telescopic and other two type single layer anastomoses. The difference is statistically significant. In oesophago-jejunostomies the pressure tolerance of telescopic anastomosis is better than of the single layer interrupted type but the difference between the telescopic and single layer continuous type anastomoses is not significant. The pressure tolerance of double layer anastomosis is higher than the telescopic one but the difference is significant only in the continuous-interrupted type. The inner pressure tolerance of telescopic and EEA stapler anastomoses are equal. The investigation of additional features in anastomosis healing is in progress.
Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types.
Sembiring, Krisnarta; Ramayani, Oke Rina; Lubis, Munar
2018-02-15
Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. To determine the difference in mean blood pressure among adolescents based on dyssomnia types. Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep Disturbance Scale for Children (SDSC) questionnaire. Stature and blood pressure data were collected along with demographic data and sleep disorder questionnaire. Analyses were done with Kruskal-Wallis test and logistic regression. P - value < 0.05 was considered significant. Seventy-six samples were obtained with mean age 13.9 (SD 1.14) years - old. Dyssomnia proportion and hypertension were 72/76 and 20/76 respectively. Mean systolic (SBP) and diastolic blood pressure (DBP) was 111.1 (SD 16.46) mmHg and 70.3 (SD 11.98) mmHg respectively. Mean SDSC score was 49.7 (SD 8.96), and the most frequent dyssomnia type was disorders of initiating and maintaining sleep. Age and sex were not the risk factors of hypertension in dyssomnia. There was a significant difference in mean SBP (P = 0.006) and DBP (P = 0.022) based on dyssomnia types. Combination dyssomnia type had the highest mean blood pressure among dyssomnia types. There is a significant difference in mean blood pressure among adolescents based on dyssomnia types.
NASA Technical Reports Server (NTRS)
Majumdar, Alok K.; LeClair, Andre C.; Hedayat, Ali
2016-01-01
This paper presents a numerical model of pressurization of a cryogenic propellant tank for the Integrated Vehicle Fluid (IVF) system using the Generalized Fluid System Simulation Program (GFSSP). The IVF propulsion system, being developed by United Launch Alliance, uses boiloff propellants to drive thrusters for the reaction control system as well as to run internal combustion engines to develop power and drive compressors to pressurize propellant tanks. NASA Marshall Space Flight Center (MSFC) has been running tests to verify the functioning of the IVF system using a flight tank. GFSSP, a finite volume based flow network analysis software developed at MSFC, has been used to develop an integrated model of the tank and the pressurization system. This paper presents an iterative algorithm for converging the interface boundary conditions between different component models of a large system model. The model results have been compared with test data.
Luttmann-Gibson, Heike; Horton, Edward S.; Cohen, Allison; Coull, Brent A.; Hoffmann, Barbara; Schwartz, Joel D.; Mittleman, Murray A.; Li, Yongsheng; Stone, Peter H.; de Souza, Celine; Lamparello, Brooke; Koutrakis, Petros; Gold, Diane R.
2014-01-01
Background: Extreme weather and air pollution are associated with increased cardiovascular risk in people with diabetes. Objectives: In a population with diabetes, we conducted a novel assessment of vascular brachial artery responses both to ambient pollution and to weather (temperature and water vapor pressure, a measure of humidity). Methods: Sixty-four 49- to 85-year-old Boston residents with type 2 diabetes completed up to five study visits (279 repeated measures). Brachial artery diameter (BAD) was measured by ultrasound before and after brachial artery occlusion [i.e., flow-mediated dilation (FMD)] and before and after nitroglycerin-mediated dilation (NMD). Ambient concentrations of fine particulate mass (PM2.5), black carbon (BC), organic carbon (OC), elemental carbon, particle number, and sulfate were measured at our monitoring site; ambient concentrations of carbon monoxide, nitrogen dioxide, and ozone were obtained from state monitors. Particle exposure in the home and during each trip to the clinic (home/trip exposure) was measured continuously and as a 5-day integrated sample. We used linear models with fixed effects for participants, adjusting for date, season, temperature, and water vapor pressure on the day of each visit, to estimate associations between our outcomes and interquartile range increases in exposure. Results: Baseline BAD was negatively associated with particle pollution, including home/trip–integrated BC (–0.02 mm; 95% CI: –0.04, –0.003, for a 0.28 μg/m3 increase in BC), OC (–0.08 mm; 95% CI: –0.14, –0.03, for a 1.61 μg/m3 increase) as well as PM2.5, 5-day average ambient PM2.5, and BC. BAD was positively associated with ambient temperature and water vapor pressure. However, exposures were not consistently associated with FMD or NMD. Conclusion: Brachial artery diameter, a predictor of cardiovascular risk, decreased in association with particle pollution and increased in association with ambient temperature in our study population of adults with type 2 diabetes. Citation: Zanobetti A, Luttmann-Gibson H, Horton ES, Cohen A, Coull BA, Hoffmann B, Schwartz JD, Mittleman MA, Li Y, Stone PH, de Souza C, Lamparello B, Koutrakis P, Gold DR. 2014. Brachial artery responses to ambient pollution, temperature, and humidity in people with type 2 diabetes: a repeated-measures study. Environ Health Perspect 122:242–248; http://dx.doi.org/10.1289/ehp.1206136 PMID:24398072
2012-01-01
Background Neuropathic diabetic foot ulceration may be prevented if the mechanical stress transmitted to the plantar tissues is reduced. Insole therapy is one practical method commonly used to reduce plantar loads and ulceration risk. The type of insole best suited to achieve this is unknown. This trial compared custom-made functional insoles with prefabricated insoles to reduce risk factors for ulceration of neuropathic diabetic feet. Method A participant-blinded randomised controlled trial recruited 119 neuropathic participants with diabetes who were randomly allocated to custom-made functional or prefabricated insoles. Data were collected at issue and six month follow-up using the F-scan in-shoe pressure measurement system. Primary outcomes were: peak pressure, forefoot pressure time integral, total contact area, forefoot rate of load, duration of load as a percentage of stance. Secondary outcomes were patient perceived foot health (Bristol Foot Score), quality of life (Audit of Diabetes Dependent Quality of Life). We also assessed cost of supply and fitting. Analysis was by intention-to-treat. Results There were no differences between insoles in peak pressure, or three of the other four kinetic measures. The custom-made functional insole was slightly more effective than the prefabricated insole in reducing forefoot pressure time integral at issue (27% vs. 22%), remained more effective at six month follow-up (30% vs. 24%, p=0.001), but was more expensive (UK £656 vs. £554, p<0.001). Full compliance (minimum wear 7 hours a day 7 days per week) was reported by 40% of participants and 76% of participants reported a minimum wear of 5 hours a day 5 days per week. There was no difference in patient perception between insoles. Conclusion The custom-made insoles are more expensive than prefabricated insoles evaluated in this trial and no better in reducing peak pressure. We recommend that where clinically appropriate, the more cost effective prefabricated insole should be considered for use by patients with diabetes and neuropathy. Trial registration Clinical trials.gov (NCT00999635). Note: this trial was registered on completion. PMID:23216959
NASA Astrophysics Data System (ADS)
Sturesson, P.; Khaji, Z.; Knaust, S.; Sundqvist, J.; Klintberg, L.; Thornell, G.
2013-12-01
This paper reports on the design, manufacturing and evaluation of a small, wirelessly powered and read resonating antenna circuit with an integrated pressure sensor. The work aims at developing miniature devices suitable for harsh environments, where high temperature prevents the use of conventional, silicon-based microdevices. Here, the device is made of alumina with platinum as conducting material. Ceramic green tapes were structured using high-precision milling, metallized using screen printing, and subsequently laminated to form stacks before they were sintered. The device's frequency shift as a function of temperature was studied up to 900°C. The contributions to the shift both from the thermomechanical deformation of the device at large, and from the integrated and, so far, self-pressurized sensor were sorted out. A total frequency shift of 3200 ppm was observed for the pressure sensor for heating over the whole range. Negligible levels of thermally induced radius of curvature were observed. With three-point bending, a frequency shift of 180 ppm was possible to induce with a curvature of radius of 220 m at a 10 N load. The results indicate that a robust pressure sensor node, which can register pressure changes of a few bars at 900°C and wirelessly transmit the signal, is viable.
The prediction of the noise of supersonic propellers in time domain - New theoretical results
NASA Technical Reports Server (NTRS)
Farassat, F.
1983-01-01
In this paper, a new formula for the prediction of the noise of supersonic propellers is derived in the time domain which is superior to the previous formulations in several respects. The governing equation is based on the Ffowcs Williams-Hawkings (FW-H) equation with the thickness source term replaced by an equivalent loading source term derived by Isom (1975). Using some results of generalized function theory and simple four-dimensional space-time geometry, the formal solution of the governing equation is manipulated to a form requiring only the knowledge of blade surface pressure data and geometry. The final form of the main result of this paper consists of some surface and line integrals. The surface integrals depend on the surface pressure, time rate of change of surface pressure, and surface pressure gradient. These integrals also involve blade surface curvatures. The line integrals which depend on local surface pressure are along the trailing edge, the shock traces on the blade, and the perimeter of the airfoil section at the inner radius of the blade. The new formulation is for the full blade surface and does not involve any numerical observer time differentiation. The method of implementation on a computer for numerical work is also discussed.
Highly stable liquid metal-based pressure sensor integrated with a microfluidic channel.
Jung, Taekeon; Yang, Sung
2015-05-21
Pressure measurement is considered one of the key parameters in microfluidic systems. It has been widely used in various fields, such as in biology and biomedical fields. The electrical measurement method is the most widely investigated; however, it is unsuitable for microfluidic systems because of a complicated fabrication process and difficult integration. Moreover, it is generally damaged by large deflection. This paper proposes a thin-film-based pressure sensor that is free from these limitations, using a liquid metal called galinstan. The proposed pressure sensor is easily integrated into a microfluidic system using soft lithography because galinstan exists in a liquid phase at room temperature. We investigated the characteristics of the proposed pressure sensor by calibrating for a pressure range from 0 to 230 kPa (R2 > 0.98) using deionized water. Furthermore, the viscosity of various fluid samples was measured for a shear-rate range of 30-1000 s(-1). The results of Newtonian and non-Newtonian fluids were evaluated using a commercial viscometer and normalized difference was found to be less than 5.1% and 7.0%, respectively. The galinstan-based pressure sensor can be used in various microfluidic systems for long-term monitoring with high linearity, repeatability, and long-term stability.
Highly Stable Liquid Metal-Based Pressure Sensor Integrated with a Microfluidic Channel
Jung, Taekeon; Yang, Sung
2015-01-01
Pressure measurement is considered one of the key parameters in microfluidic systems. It has been widely used in various fields, such as in biology and biomedical fields. The electrical measurement method is the most widely investigated; however, it is unsuitable for microfluidic systems because of a complicated fabrication process and difficult integration. Moreover, it is generally damaged by large deflection. This paper proposes a thin-film-based pressure sensor that is free from these limitations, using a liquid metal called galinstan. The proposed pressure sensor is easily integrated into a microfluidic system using soft lithography because galinstan exists in a liquid phase at room temperature. We investigated the characteristics of the proposed pressure sensor by calibrating for a pressure range from 0 to 230 kPa (R2 > 0.98) using deionized water. Furthermore, the viscosity of various fluid samples was measured for a shear-rate range of 30–1000 s−1. The results of Newtonian and non-Newtonian fluids were evaluated using a commercial viscometer and normalized difference was found to be less than 5.1% and 7.0%, respectively. The galinstan-based pressure sensor can be used in various microfluidic systems for long-term monitoring with high linearity, repeatability, and long-term stability. PMID:26007732
Owings, Tammy M; Woerner, Julie L; Frampton, Jason D; Cavanagh, Peter R; Botek, Georgeanne
2008-05-01
The purpose of this study was to determine whether custom insoles tailored to contours of the barefoot pressure distribution and shape of a patient's foot can reduce plantar pressures in the metatarsal head (MTH) region to a greater extent than conventional custom insoles. Seventy regions of elevated barefoot pressures (mean peak 834 kPa under MTHs) were identified in 20 subjects with diabetes. Foam box impressions of their feet were sent to three different orthotic supply companies for fabrication of custom insoles. One company was also given plantar pressure data, which were incorporated into the insole design. Measurements of in-shoe plantar pressures were recorded during gait for the three custom insoles in a flexible and a rocker-bottom shoe. Peak pressure and force-time integral were extracted for analysis. In 64 of 70 regions, the shape-plus-pressure-based insole in the flexible shoe achieved superior unloading compared with the two shape-based insoles. On average, peak pressure was reduced by 32 and 21% (both P
Modelling and control of a diffusion/LPCVD furnace
NASA Astrophysics Data System (ADS)
Dewaard, H.; Dekoning, W. L.
1988-12-01
Heat transfer inside a cylindrical resistance diffusion/Low Pressure Chemical Vapor Deposition (LPCVD) furnace is studied with the aim of developing an improved temperature controller. A model of the thermal behavior is derived, which covers the important class of furnaces equipped with semitransparent quartz process tubes. The model takes into account the thermal behavior of the thermocouples. Currently used temperature controllers are shown to be highly inefficient for very large scale integration applications. Based on the model an alternative temperature controller of the LQG (linear quadratic Gaussian) type is proposed which features direct wafer temperature control. Some simulation results are given.
NASA Technical Reports Server (NTRS)
Watkins, Charles E; Durling, Barbara J
1956-01-01
This report presents tabulated values of certain definite integral that are involved in the calculation of near-field propeller noise when the chordwise forces are assumed to be either uniform or of a Dirac delta type. The tabulations are over a wide range of operating conditions and are useful for estimating propeller noise when either the concept of an effective radius or radial distributions of forces are considered. Use of the tabulations is illustrated by several examples of calculated results for some specific propellers.
Energy efficient engine low-pressure compressor component test hardware detailed design report
NASA Technical Reports Server (NTRS)
Michael, C. J.; Halle, J. E.
1981-01-01
The aerodynamic and mechanical design description of the low pressure compressor component of the Energy Efficient Engine were used. The component was designed to meet the requirements of the Flight Propulsion System while maintaining a low cost approach in providing a low pressure compressor design for the Integrated Core/Low Spool test required in the Energy Efficient Engine Program. The resulting low pressure compressor component design meets or exceeds all design goals with the exception of surge margin. In addition, the expense of hardware fabrication for the Integrated Core/Low Spool test has been minimized through the use of existing minor part hardware.
Massive Air Embolism in a Fontan Patient
Matte, Gregory S.; Kussman, Barry D.; Wagner, Joseph W.; Boyle, Sharon L.; Howe, Robert J.; Pigula, Frank A.; Emani, Sitaram M.
2011-01-01
Abstract: Most institutions performing cardiopulmonary bypass for congenital heart disease patients use an integrated hard shell cardiotomy and venous reservoir attached to an oxygenator. It is of paramount importance that the integrated reservoir be vented so as not to cause pressurization. A pressurized sealed cardiotomy has been reported to occur secondary to issues with vacuum assisted venous drainage systems as well as improper venting in general. We report a case of air embolus caused by retrograde propulsion of air through the venous line secondary to a pressurized cardiotomy reservoir in a patient with Fontan circulation. The mechanism of cardiotomy pressurization is described, and the scenario simulated in a mock circuit. PMID:21848177
Massive air embolism in a Fontan patient.
Matte, Gregory S; Kussman, Barry D; Wagner, Joseph W; Boyle, Sharon L; Howe, Robert J; Pigula, Frank A; Emani, Sitaram M
2011-06-01
Most institutions performing cardiopulmonary bypass for congenital heart disease patients use an integrated hard shell cardiotomy and venous reservoir attached to an oxygenator. It is of paramount importance that the integrated reservoir be vented so as not to cause pressurization. A pressurized sealed cardiotomy has been reported to occur secondary to issues with vacuum assisted venous drainage systems as well as improper venting in general. We report a case of air embolus caused by retrograde propulsion of air through the venous line secondary to a pressurized cardiotomy reservoir in a patient with Fontan circulation. The mechanism of cardiotomy pressurization is described, and the scenario simulated in a mock circuit.
Wigle, E. Douglas; Auger, Pierre; Marquis, Yves
1966-01-01
Two types of intraventricular pressure differences within the left ventricle of man are described. The first is encountered in cases of muscular (or fibrous) subaortic stenosis, in which the outflow tract pressure distal to the stenosis (and proximal to the aortic valve) is low, whereas all pressures recorded in the left ventricle proximal to the stenosis, including that just inside the mitral valve (the initial inflow tract pressure) are high. The second type of intraventricular pressure difference may be recorded in patients without muscular subaortic stenosis when a heart catheter is advanced to the left ventricular wall in such a manner that it becomes imbedded or entrapped by cardiac muscle in systole. Such an entrapped catheter records a high intraventricular pressure that is believed to reflect intramyocardial tissue pressure, which normally exceeds intracavitary pressure. In such cases the initial inflow tract pressure is not high and is precisely equal to the outflow tract systolic pressure, i.e. both are recording intracavity pressure. This type of intramyocardial to intracavitary pressure difference may also be encountered in the left ventricle of dogs. The recent suggestion that intraventricular pressure differences in the left ventricle of cases of muscular subaortic stenosis are due to catheter entrapment by cardiac muscle is refuted by using the initial inflow tract pressure as the means of differentiation between the two types of intraventricular pressure differences outlined. PMID:5951625
2016-01-01
Background. Changes in biomechanical structures of human foot are common in the older person, which may lead to alteration of foot type and plantar pressure distribution. We aimed to examine how foot type affects the plantar pressure distribution and to determine the relationship between plantar pressure distribution and functional reach distance in older persons. Methods. Fifty community-dwelling older persons (age: 69.98 ± 5.84) were categorized into three groups based on the Foot Posture Index. The plantar pressure (maxP) and contact area were analyzed using Footscan® RSScan platform. The Kruskal-Wallis test was used to compare the plantar pressure between foot types and Spearman's correlation coefficient was used to correlate plantar pressure with the functional reach distance. Results. There were significant differences of maxP in the forefoot area across all foot types. The post hoc analysis found significantly lower maxP in the pronated foot compared to the supinated foot. A high linear rank correlation was found between functional reach distance and maxP of the rearfoot region of the supinated foot. Conclusions. These findings suggested that types of the foot affect the plantar maximal pressure in older persons with functional reach distance showing some associations. PMID:27980874
Yang, Hua; Gao, Jian; Ren, Limin; Li, Shuyu; Chen, Zhangyan; Huang, Junfang; Zhu, Shanzhu; Pan, Zhigang
2017-01-01
Knowledge-attitude-practices (KAP) significantly impact the outcome of self-management in patients with diabetes, yet the association between KAP and the combined control of the levels of blood glucose, blood pressure, and blood lipids in these patients remains uncertain. This community-based cross-sectional study was conducted from December 2014 to December 2016 on 3977 patients with type 2 diabetes in Shanghai. KAP were evaluated using the modified Chinese version of the Diabetes, Hypertension and Hyperlipidemia (DHL) Knowledge Instrument, Diabetes Empowerment Scale-Short Form (DES-SF), and Summary of Diabetes Self-Care Activities (SDSCA). Clinical and biochemical measurements were performed at each sampling site. The association between KAP scores and achieving the combined target goal was assessed by multiple logistic regression. Patients having a higher score of knowledge were more likely to achieve the combined target goal. Furthermore, a turning point of knowledge score was found that the possibility of achieving the combined target goal presented a sharp increase when the knowledge score was more than 70. However, the scores of attitude and practices had no significant relations with achieving the combined target goal. Health intervention strategies, especially increasing integrated diabetes knowledge, should be targeted to patients with type 2 diabetes in communities.
New well testing applications of the pressure derivative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onur, M.
1989-01-01
This work presents new derivative type curves based on a new derivative group which is equal to the dimensionless pressure group divided by its logarithmic derivative with respect to dimensionless time group. One major advantage of these type curves is that the type-curve match of field pressure/pressure-derivative data with the new derivative type curves is accomplished by moving the field data plot in only the horizontal direction. This type-curve match fixes time match-point values. The pressure change versus time data is then matched with the dimensionless pressure solution to determine match-point values. Well/reservoir parameters can then be estimated in themore » standard way. This two step type-curve matching procedure increases the likelihood of obtaining a unique match. Moreover, the unique correspondence between the ordinate of the field data plot and the new derivative type curves should prove useful in determining whether given field data actually represents the well/reservoir model assumed by a selected type curve solution. It is also shown that the basic idea used in construction the type curves can be used to ensure that proper semilog straight lines are chosen when analyzing pressure data by semilog methods. Analysis of both drawdown and buildup data is considered and actual field cases are analyzed using the new derivative type curves and the semilog identification method. This work also presents new methods based on the pressure derivative to analyze buildup data obtained at a well (fracture or unfractured) produced to pseudosteady-state prior to shut-in. By using a method of analysis based on the pressure derivative, it is shown that a well's drainage area at the instant of shut-in and the flow capacity can be computed directly from buildup data even in cases where conventional semilog straight lines are not well-defined.« less
A novel integrated multifunction micro-sensor for three-dimensional micro-force measurements.
Wang, Weizhong; Zhao, Yulong; Qin, Yafei
2012-01-01
An integrated multifunction micro-sensor for three-dimensional micro-force precision measurement under different pressure and temperature conditions is introduced in this paper. The integrated sensor consists of three kinds of sensors: a three-dimensional micro-force sensor, an absolute pressure sensor and a temperature sensor. The integrated multifunction micro-sensor is fabricated on silicon wafers by micromachining technology. Different doping doses of boron ion, placement and structure of resistors are tested for the force sensor, pressure sensor and temperature sensor to minimize the cross interference and optimize the properties. A glass optical fiber, with a ladder structure and sharp tip etched by buffer oxide etch solution, is glued on the micro-force sensor chip as the tactile probe. Experimental results show that the minimum force that can be detected by the force sensor is 300 nN; the lateral sensitivity of the force sensor is 0.4582 mV/μN; the probe length is linearly proportional to sensitivity of the micro-force sensor in lateral; the sensitivity of the pressure sensor is 0.11 mv/KPa; the sensitivity of the temperature sensor is 5.836 × 10(-3) KΩ/°C. Thus it is a cost-effective method to fabricate integrated multifunction micro-sensors with different measurement ranges that could be used in many fields.
NASA Astrophysics Data System (ADS)
Madhavi, M.; Venkat, R.
2014-01-01
Fiber reinforced polymer composite materials with their higher specific strength, moduli and tailorability characteristics will result in reduction of weight of the structure. The composite pressure vessels with integrated end domes develop hoop stresses that are twice longitudinal stresses and when isotropic materials like metals are used for development of the hardware and the material is not fully utilized in the longitudinal/meridional direction resulting in over weight components. The determination of a proper winding angles and thickness is very important to decrease manufacturing difficulties and to increase structural efficiency. In the present study a methodology is developed to understand structural characteristics of filament wound pressure vessels with integrated end domes. Progressive ply wise failure analysis of composite pressure vessel with geodesic end domes is carried out to determine matrix crack failure, burst pressure values at various positions of the shell. A three dimensional finite element analysis is computed to predict the deformations and stresses in the composite pressure vessel. The proposed method could save the time to design filament wound structures, to check whether the ply design is safe for the given input conditions and also can be adapted to non-geodesic structures. The results can be utilized to understand structural characteristics of filament wound pressure vessels with integrated end domes. This approach can be adopted for various applications like solid rocket motor casings, automobile fuel storage tanks and chemical storage tanks. Based on the predictions a composite pressure vessel is designed and developed. Hydraulic test is performed on the composite pressure vessel till the burst pressure.
30 CFR 250.1611 - Blowout preventer systems tests, actuations, inspections, and maintenance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... conducting high-pressure tests, all BOP systems shall be tested to a pressure of 200 to 300 psi. (b) Ram-type BOP's and the choke manifold shall be pressure tested with water to rated working pressure or as otherwise approved by the District Manager. Annular type BOP's shall be pressure tested with water to 70...
NASA Technical Reports Server (NTRS)
Majumdar, Alok; Valenzuela, Juan; LeClair, Andre; Moder, Jeff
2015-01-01
This paper presents a numerical model of a system-level test bed - the multipurpose hydrogen test bed (MHTB) using Generalized Fluid System Simulation Program (GFSSP). MHTB is representative in size and shape of a fully integrated space transportation vehicle liquid hydrogen (LH2) propellant tank and was tested at Marshall Space Flight Center (MSFC) to generate data for cryogenic storage. GFSSP is a finite volume based network flow analysis software developed at MSFC and used for thermo-fluid analysis of propulsion systems. GFSSP has been used to model the self-pressurization and ullage pressure control by Thermodynamic Vent System (TVS). A TVS typically includes a Joule-Thompson (J-T) expansion device, a two-phase heat exchanger, and a mixing pump and spray to extract thermal energy from the tank without significant loss of liquid propellant. Two GFSSP models (Self-Pressurization & TVS) were separately developed and tested and then integrated to simulate the entire system. Self-Pressurization model consists of multiple ullage nodes, propellant node and solid nodes; it computes the heat transfer through Multi-Layer Insulation blankets and calculates heat and mass transfer between ullage and liquid propellant and ullage and tank wall. TVS model calculates the flow through J-T valve, heat exchanger and spray and vent systems. Two models are integrated by exchanging data through User Subroutines of both models. The integrated models results have been compared with MHTB test data of 50% fill level. Satisfactory comparison was observed between test and numerical predictions.
Etzion, Y; Grossman, Y
2000-11-01
High pressure induces CNS hyperexcitability while markedly depressing synaptic transmitter release. We studied the effect of pressure (up to 10.1 MPa) on the parallel fibre (PF) synaptic response in biplanar cerebellar slices of adult guinea pigs. Pressure mildly reduced the PF volley amplitude and to a greater extent depressed the excitatory field postsynaptic potential (fPSP). The depression of the PF volley was noted even at supramaximal stimulus intensities, indicating an effect of pressure on the amplitude of the action potential in each axon. Low concentrations of TTX mimicked the effects of pressure on the PF volley without affecting the fPSP. Application omega-conotoxin GVIA (omega-CgTx) reduced the synaptic efficacy by 34.3+/-2.7%. However, in the presence of omega-CgTx the synaptic depression at pressure was significantly reduced. Reduced Ca2+ entry by application of Cd2+ or low [Ca2+]o did not have a similar influence on the effects of pressure. Application of omega-AGA IVA, omega-AGA TK and Funnel-web spider toxin did not affect the synaptic response in concentrations that usually block P-type Ca2+ channels, whilst the N/P/Q-type blocker omega-conotoxin MVIIC reduced the response to 52.7+/-5.0% indicating the involvement of Q-type channels and R-type channels in the non-N-type fraction of Ca2+ entry. The results demonstrate that N-type Ca2+ channels play a crucial role in the induction of PF synaptic depression at pressure. This finding suggests a coherent mechanism for the induction of CNS hyperexcitability at pressure.
Battery management systems with thermally integrated fire suppression
Bandhauer, Todd M.; Farmer, Joseph C.
2017-07-11
A thermal management system is integral to a battery pack and/or individual cells. It relies on passive liquid-vapor phase change heat removal to provide enhanced thermal protection via rapid expulsion of inert high pressure refrigerant during abnormal abuse events and can be integrated with a cooling system that operates during normal operation. When a thermal runaway event occurs and sensed by either active or passive sensors, the high pressure refrigerant is preferentially ejected through strategically placed passages within the pack to rapidly quench the battery.
Launcher Dynamic Data Acquisition
2012-07-31
K PR Pressure PR Pressure PR Accelerometer PR Accelerometer PR Accelerometer PR Pressure PR Pressure IEPE Microphone IEPE ...transducers, displacement potentiometers, or Integrated Electronics Piezoelectric ( IEPE ) microphones and accelerometers. The characteristics of these...Engineering Units HCl hydrogen chloride HVAC heating ventilation and cooling Hz hertz IEC International Electrotechnical Commission IEPE
Microelectromechanical system pressure sensor integrated onto optical fiber by anodic bonding.
Saran, Anish; Abeysinghe, Don C; Boyd, Joseph T
2006-03-10
Optical microelectromechanical system pressure sensors based on the principle of Fabry-Perot interferometry have been developed and fabricated using the technique of silicon-to-silicon anodic bonding. The pressure sensor is then integrated onto an optical fiber by a novel technique of anodic bonding without use of any adhesives. In this anodic bonding technique we use ultrathin silicon of thickness 10 microm to bond the optical fiber to the sensor head. The ultrathin silicon plays the role of a stress-reducing layer, which helps the bonding of an optical fiber to silicon having conventional wafer thickness. The pressure-sensing membrane is formed by 8 microm thick ultrathin silicon acting as a membrane, thus eliminating the need for bulk silicon etching. The pressure sensor integrated onto an optical fiber is tested for static response, and experimental results indicate degradation in the fringe visibility of the Fabry-Perot interferometer. This effect was mainly due to divergent light rays from the fiber degrading the fringe visibility. This effect is demonstrated in brief by an analytical model.
Zhao, Jianhua; Jin, Zhijun; Hu, Qinhong; Jin, Zhenkui; Barber, Troy J; Zhang, Yuxiang; Bleuel, Markus
2017-11-13
An integration of small-angle neutron scattering (SANS), low-pressure N 2 physisorption (LPNP), and mercury injection capillary pressure (MICP) methods was employed to study the pore structure of four oil shale samples from leading Niobrara, Wolfcamp, Bakken, and Utica Formations in USA. Porosity values obtained from SANS are higher than those from two fluid-invasion methods, due to the ability of neutrons to probe pore spaces inaccessible to N 2 and mercury. However, SANS and LPNP methods exhibit a similar pore-size distribution, and both methods (in measuring total pore volume) show different results of porosity and pore-size distribution obtained from the MICP method (quantifying pore throats). Multi-scale (five pore-diameter intervals) inaccessible porosity to N 2 was determined using SANS and LPNP data. Overall, a large value of inaccessible porosity occurs at pore diameters <10 nm, which we attribute to low connectivity of organic matter-hosted and clay-associated pores in these shales. While each method probes a unique aspect of complex pore structure of shale, the discrepancy between pore structure results from different methods is explained with respect to their difference in measurable ranges of pore diameter, pore space, pore type, sample size and associated pore connectivity, as well as theoretical base and interpretation.
WNK kinases and renal sodium transport in health and disease: an integrated view
McCormick, James; Yang, Chao-Ling; Ellison, David H.
2011-01-01
The with no lysine (WNK) kinases comprise a novel branch of the human kinome that plays a central role in regulating renal sodium, potassium, and chloride transport, and, therefore, blood pressure. Mutations of two WNK kinases, WNK1 and WNK4, cause familial hyperkalemic hypertension (Gordon’s syndrome or Type II pseudohypoaldosteronism), a rare monogenic disease. Many aspects of WNK action have been elucidated during the past seven years. WNKs are all expressed along a short segment of renal distal tubule, where they modulate the activity of a wide variety of transport proteins. These diverse effects, however, make it difficult to describe an integrated model of WNK function within the kidney. Recently, work in vivo and in vitro has begun to clarify this picture. The present review emphasizes recent insights into mechanism by which WNK kinases interact to modulate sodium and potassium transport along the aldosterone-sensitive distal nephron. We describe a potential mechanism by which WNK4 mutations convert the action of WNK4 from inhibiting renal sodium chloride retention to stimulating it, thereby affecting both blood pressure and potassium balance. An explanation for how WNK kinases can alter the effects of aldosterone from primarily kaliuretic to primarily sodium chloride retentive, according to physiological need, is also described. PMID:18212265
M113 Electric Land Drive Demonstration Project. Volume 1: Vehicle Systems Design and Integration
1992-08-01
pickup for L-final drive output speed MP-5 Magnetic pickup for engine speed Pressure Switches PS-I Pressure switch for gearbox pressure (5 lb/in2 ) PS...2 Pressure switch for ac generator pressure (5 lb/in 2 ) PS-3 Pressure switch for dc generator pressure (5 lb/in2 ) PS-4 Pressure switch for ac...generator-i scavenge pressure (5 lb/in 2 ) PS-5 Pressure switch for ac generator-2 scavenge pressure (5 lb/in2 ) PS-6 Pressure switch for engine
Kuyper, Lisette; de Wit, John; Smolenski, Derek; Adam, Philippe; Woertman, Liesbeth; van Berlo, Willy
2013-11-01
The development of effective policies and programs to prevent sexual coercion among young people requires thorough understanding of the diversity of coercive sexual experiences, patterns in such types of experiences, and similarities and differences between subgroups, especially by gender, in patterns of coercive sexual experiences and associations with potential vulnerability factors. The present online self-report study assessed a wide range of coercive sexual experiences and potential vulnerability factors among a sociodemographically diverse sample of 1,319 young people (16-25 years old) in The Netherlands. Findings confirm that sexual coercion comprises a diversity of experiences, with rates differing substantially across types of coercion. Latent class analysis revealed distinct patterns of coercive sexual experiences for young women and young men. Among young men, three patterns of experiences were found: no coercive sexual experiences, experience with verbal pressure, and experience with verbal pressure as well as coercion related to alcohol intoxication. Among young women, four patterns of coercive experiences were identified. In addition to the three patterns observed among young men, a fourth pattern encompassed experiences with verbal pressure as well as the use of force or violence. Higher numbers of sexual partners, lower levels of sexual refusal skills, and higher levels of token resistance were consistently associated with increased vulnerability. Findings illustrate the importance of communication skills and suggest that sexual communication training should be an integral part of sexuality education.
Tenten-Diepenmaat, Marloes; Dekker, Joost; Steenbergen, Menno; Huybrechts, Elleke; Roorda, Leo D; van Schaardenburg, Dirkjan; Bus, Sicco A; van der Leeden, Marike
2016-03-01
Improving foot orthoses (FOs) in patients with rheumatoid arthritis (RA) by using in-shoe plantar pressure measurements seems promising. The objectives of this study were to evaluate (1) the outcome on plantar pressure distribution of FOs that were adapted using in-shoe plantar pressure measurements according to a protocol and (2) the protocol feasibility. Forty-five RA patients with foot problems were included in this observational proof-of concept study. FOs were custom-made by a podiatrist according to usual care. Regions of Interest (ROIs) for plantar pressure reduction were selected. According to a protocol, usual care FOs were evaluated using in-shoe plantar pressure measurements and, if necessary, adapted. Plantar pressure-time integrals at the ROIs were compared between the following conditions: (1) no-FO versus usual care FO and (2) usual care FO versus adapted FO. Semi-structured interviews were held with patients and podiatrists to evaluate the feasibility of the protocol. Adapted FOs were developed in 70% of the patients. In these patients, usual care FOs showed a mean 9% reduction in pressure-time integral at forefoot ROIs compared to no-FOs (p=0.01). FO adaptation led to an additional mean 3% reduction in pressure-time integral (p=0.05). The protocol was considered feasible by patients. Podiatrists considered the protocol more useful to achieve individual rather than general treatment goals. A final protocol was proposed. Using in-shoe plantar pressure measurements for adapting foot orthoses for patients with RA leads to a small additional plantar pressure reduction in the forefoot. Further research on the clinical relevance of this outcome is required. Copyright © 2016. Published by Elsevier B.V.
Spurgeon, Peter; Mazelan, Patti; Barwell, Fred
2012-02-01
This paper briefly describes the OSM (Organizational Stress Measure) which was developed over a decade ago and has evolved to become a well-established practical method not only for assessing wellbeing at work but also as a cost-effective strategy to tackle workplace stress. The OSM measures perceived organizational pressures and felt individual strains within the same instrument, and provides a rich and subtle picture of both the organizational culture and the personal perspectives of the constituent staff groups. There are many types of organizational pressure that may impact upon the wellbeing and potential effectiveness of staff including skill shortages, ineffective strategic planning and poor leadership, and these frequently result in reduced performance, absenteeism, high turnover and poor staff morale. These pressures may increase the probability of some staff reacting negatively and research with the OSM has shown that increased levels of strain for small clusters of staff may be a leading indicator of future organizational problems. One of the main benefits of using the OSM is the ability to identify 'hot-spots', where organizational pressures are triggering high levels of personal strain in susceptible clusters of staff. In this way, the OSM may act as an 'early warning alarm' for potential organizational problems.
Highly Parallel Alternating Directions Algorithm for Time Dependent Problems
NASA Astrophysics Data System (ADS)
Ganzha, M.; Georgiev, K.; Lirkov, I.; Margenov, S.; Paprzycki, M.
2011-11-01
In our work, we consider the time dependent Stokes equation on a finite time interval and on a uniform rectangular mesh, written in terms of velocity and pressure. For this problem, a parallel algorithm based on a novel direction splitting approach is developed. Here, the pressure equation is derived from a perturbed form of the continuity equation, in which the incompressibility constraint is penalized in a negative norm induced by the direction splitting. The scheme used in the algorithm is composed of two parts: (i) velocity prediction, and (ii) pressure correction. This is a Crank-Nicolson-type two-stage time integration scheme for two and three dimensional parabolic problems in which the second-order derivative, with respect to each space variable, is treated implicitly while the other variable is made explicit at each time sub-step. In order to achieve a good parallel performance the solution of the Poison problem for the pressure correction is replaced by solving a sequence of one-dimensional second order elliptic boundary value problems in each spatial direction. The parallel code is implemented using the standard MPI functions and tested on two modern parallel computer systems. The performed numerical tests demonstrate good level of parallel efficiency and scalability of the studied direction-splitting-based algorithm.
Braun, Fabian; Ferrario, Damien; Rossi, René M.; Scheel-Sailer, Anke; Wolf, Martin; Bona, Gian-Luca; Hufenus, Rudolf; Scherer, Lukas J.
2017-01-01
Knowledge of an individual's skin condition is important for pressure ulcer prevention. Detecting early changes in skin through perfusion, oxygen saturation values, and pressure on tissue and subsequent therapeutic intervention could increase patients' quality of life drastically. However, most existing sensing options create additional risk of ulcer development due to further pressure on and chafing of the skin. Here, as a first component, we present a flexible, photonic textile-based sensor for the continuous monitoring of the heartbeat and blood flow. Polymer optical fibres (POFs) are melt-spun continuously and characterized optically and mechanically before being embroidered. The resulting sensor shows flexibility when embroidered into a moisture-wicking fabric, and withstands disinfection with hospital-type laundry cycles. Additionally, the new sensor textile shows a lower static coefficient of friction (COF) than conventionally used bedsheets in both dry and sweaty conditions versus a skin model. Finally, we demonstrate the functionality of our sensor by measuring the heartbeat at the forehead in reflection mode and comparing it with commercial finger photoplethysmography for several subjects. Our results will allow the development of flexible, individualized, and fully textile-integrated wearable sensors for sensitive skin conditions and general long-term monitoring of patients with risk for pressure ulcer. PMID:28275123
Quandt, Brit M; Braun, Fabian; Ferrario, Damien; Rossi, René M; Scheel-Sailer, Anke; Wolf, Martin; Bona, Gian-Luca; Hufenus, Rudolf; Scherer, Lukas J; Boesel, Luciano F
2017-03-01
Knowledge of an individual's skin condition is important for pressure ulcer prevention. Detecting early changes in skin through perfusion, oxygen saturation values, and pressure on tissue and subsequent therapeutic intervention could increase patients' quality of life drastically. However, most existing sensing options create additional risk of ulcer development due to further pressure on and chafing of the skin. Here, as a first component, we present a flexible, photonic textile-based sensor for the continuous monitoring of the heartbeat and blood flow. Polymer optical fibres (POFs) are melt-spun continuously and characterized optically and mechanically before being embroidered. The resulting sensor shows flexibility when embroidered into a moisture-wicking fabric, and withstands disinfection with hospital-type laundry cycles. Additionally, the new sensor textile shows a lower static coefficient of friction (COF) than conventionally used bedsheets in both dry and sweaty conditions versus a skin model. Finally, we demonstrate the functionality of our sensor by measuring the heartbeat at the forehead in reflection mode and comparing it with commercial finger photoplethysmography for several subjects. Our results will allow the development of flexible, individualized, and fully textile-integrated wearable sensors for sensitive skin conditions and general long-term monitoring of patients with risk for pressure ulcer. © 2017 The Author(s).
Harnessing solar pressure to slew and point large infrared space telescopes
NASA Astrophysics Data System (ADS)
Errico, Simona; Angel, Roger P.; Calvert, Paul D.; Woof, Neville
2003-03-01
Large astronomical Gossamer telescopes in space will need to employ large solar shields to safeguard the optics from solar radiation. These types of telescopes demand accurate controls to maintain telescope pointing over long integration periods. We propose an active solar shield system that harnesses radiation pressure to accurately slew and acquire new targets without the need for reaction wheels or thrusters. To provide the required torques, the solar shield is configured as an inverted, 4-sided pyramidal roof. The sloped roof interior surfaces are covered with hinged “tiles” made from piezoelectric film bimorphs with specular metallized surfaces. Nominally, the tiles lie flat against the roof and the sunlight is reflected outward equally from all sloped surfaces. However, when the tiles on one roof pitch are raised, the pressure balance is upset and the sunshade is pushed to one side. By judicious selection of the tiles and control of their lift angle, the solar pressure can be harvested to stabilize the spacecraft orientation or to change its angular momentum. A first order conceptual design performance analysis and the results from the experimental design, fabrication and testing of piezoelectric bimorph hinge elements will be presented. Next phase challenges in engineering design, materials technology, and systems testing will be discussed.
NASA Astrophysics Data System (ADS)
Sugano, Koji; Matsumoto, Ryu; Tsutsui, Ryota; Kishihara, Hiroyuki; Matsuzuka, Naoki; Yamashita, Ichiro; Uraoka, Yukiharu; Isono, Yoshitada
2016-07-01
This study focuses on the development of a multi-walled carbon nanotube (MWCNT) forest integrated micromechanical resonator working as a rarefied gas analyzer for nitrogen (N2) and hydrogen (H2) gases in a medium vacuum atmosphere. The resonant response is detected in the form of changes in the resonant frequency or damping effects, depending on the rarefied gas species. The carbon nanotube (CNT) forest on the resonator enhances the effective specific surface area of the resonator, such that the variation of the resonant frequency and the damping effect based on the gas species increase significantly. We developed the fabrication process for the proposed resonator, which consists of standard micro-electro-mechanical systems (MEMS) processes and high-density CNT synthesis on the resonator mass. The high-density CNT synthesis was realized using multistep alternate coating of two types of ferritin proteins that act as catalytic iron particles. Two devices with different CNT densities were fabricated and characterized to evaluate the effect of the surface area of the CNT forest on the resonant response as a function of gas pressures ranging from 0.011 to 1 Pa for N2 and H2. Considering the damping effect, we found that the device with higher density was able to distinguish N2 and H2 clearly, whereas the device with lower density showed no difference between N2 and H2. We confirmed that a larger surface area showed a higher damping effect. These results were explained based on the kinetic theory of gases. In the case of resonant frequency, the relative resonant frequency shift increased with gas pressure and surface area because of the adsorption of gas molecules on the resonator surfaces. Higher density CNT forest adsorbed more gas molecules on the surfaces. The developed CNT forest integrated micromechanical resonator could successfully detect N2 and H2 gases and distinguish between them under pressures of 1 Pa.
Green, Lawrence W; Brancati, Frederick L; Albright, Ann
2012-01-01
Type 2 diabetes imposes a large and growing burden on the public’s health. This burden, combined with the growing evidence for primary prevention from randomized controlled trials of structured lifestyle programs leads to recommendations to include caloric reduction, increased physical activity and specific assistance to patients in problem solving to achieve modest weight loss as well as pharmacotherapy. These recommendations demand exploration of new ways to implement such primary prevention strategies through more integrated community organization, medical practice and policy. The US experience with control of tobacco use and high blood pressure offers valuable lessons for policy, such as taxation on products, and for practice in a variety of settings, such as coordination of referrals for lifestyle supports. We acknowledge also some notable exceptions to their generalizability. This paper presents possible actions proposed by an expert panel, summarized in Table 1 as recommendations for immediate action, strategic action and research. The collaboration of primary care and public health systems will be required to make many of these recommendations a reality. This paper also provides information on the progress made in recent years by the Division of Diabetes Translation at the US Centers for Disease Control and Prevention (CDC) to implement or facilitate such integration of primary care and public health for primary prevention. PMID:22399542
[Gas Concentration Measurement Based on the Integral Value of Absorptance Spectrum].
Liu, Hui-jun; Tao, Shao-hua; Yang, Bing-chu; Deng, Hong-gui
2015-12-01
The absorptance spectrum of a gas is the basis for the qualitative and quantitative analysis of the gas by the law of the Lambert-Beer. The integral value of the absorptance spectrum is an important parameter to describe the characteristics of the gas absorption. Based on the measured absorptance spectrum of a gas, we collected the required data from the database of HIT-RAN, and chose one of the spectral lines and calculated the integral value of the absorptance spectrum in the frequency domain, and then substituted the integral value into Lambert-Beer's law to obtain the concentration of the detected gas. By calculating the integral value of the absorptance spectrum we can avoid the more complicated calculation of the spectral line function and a series of standard gases for calibration, so the gas concentration measurement will be simpler and faster. We studied the changing trends of the integral values of the absorptance spectrums versus temperature. Since temperature variation would cause the corresponding variation in pressure, we studied the changing trends of the integral values of the absorptance spectrums versus both the pressure not changed with temperature and changed with the temperature variation. Based on the two cases, we found that the integral values of the absorptance spectrums both would firstly increase, then decrease, and finally stabilize with temperature increasing, but the ranges of specific changing trend were different in the two cases. In the experiments, we found that the relative errors of the integrated values of the absorptance spectrum were much higher than 1% and still increased with temperature when we only considered the change of temperature and completely ignored the pressure affected by the temperature variation, and the relative errors of the integrated values of the absorptance spectrum were almost constant at about only 1% when we considered that the pressure were affected by the temperature variation. As the integral value of the absorptance spectrum varied with temperature and the calculating error for the integral value fluctuates with ranges of temperature, in the gas measurement when we usd integral values of the absoptance spectrum, we should select a suitable temperature variation and obtain a more accurate measurement result.
Code of Federal Regulations, 2012 CFR
2012-10-01
... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...
Code of Federal Regulations, 2013 CFR
2013-10-01
... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...
Code of Federal Regulations, 2014 CFR
2014-10-01
... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...
NASA Technical Reports Server (NTRS)
Morehead, R. L.; Atwell, M. J.; Melcher, J. C.; Hurlbert, E. A.
2016-01-01
A prototype cold helium active pressurization system was incorporated into an existing liquid oxygen (LOX) / liquid methane (LCH4) prototype planetary lander and hot-fire tested to collect vehicle-level performance data. Results from this hot-fire test series were used to validate integrated models of the vehicle helium and propulsion systems and demonstrate system effectiveness for a throttling lander. Pressurization systems vary greatly in complexity and efficiency between vehicles, so a pressurization performance metric was also developed as a means to compare different active pressurization schemes. This implementation of an active repress system is an initial sizing draft. Refined implementations will be tested in the future, improving the general knowledge base for a cryogenic lander-based cold helium system.
Szulcek, Robert; van Bezu, Jan; Boonstra, Johannes; van Loon, Jack J. W. A.; van Nieuw Amerongen, Geerten P.
2015-01-01
Background Endothelial cells (EC) guard vascular functions by forming a dynamic barrier throughout the vascular system that sensitively adapts to ‘classical’ biomechanical forces, such as fluid shear stress and hydrostatic pressure. Alterations in gravitational forces might similarly affect EC integrity, but remain insufficiently studied. Methods In an unique approach, we utilized Electric Cell-substrate Impedance Sensing (ECIS) in the gravity-simulators at the European Space Agency (ESA) to study dynamic responses of human EC to simulated micro- and hyper-gravity as well as to classical forces. Results Short intervals of micro- or hyper-gravity evoked distinct endothelial responses. Stimulated micro-gravity led to decreased endothelial barrier integrity, whereas hyper-gravity caused sustained barrier enhancement by rapid improvement of cell-cell integrity, evidenced by a significant junctional accumulation of VE-cadherin (p = 0.011), significant enforcement of peripheral F-actin (p = 0.008) and accompanied by a slower enhancement of cell-matrix interactions. The hyper-gravity triggered EC responses were force dependent and nitric-oxide (NO) mediated showing a maximal resistance increase of 29.2±4.8 ohms at 2g and 60.9±6.2 ohms at 4g vs. baseline values that was significantly suppressed by NO blockage (p = 0.011). Conclusion In conclusion, short-term application of hyper-gravity caused a sustained improvement of endothelial barrier integrity, whereas simulated micro-gravity weakened the endothelium. In clear contrast, classical forces of shear stress and hydrostatic pressure induced either short-lived or no changes to the EC barrier. Here, ECIS has proven a powerful tool to characterize subtle and distinct EC gravity-responses due to its high temporal resolution, wherefore ECIS has a great potential for the study of gravity-responses such as in real space flights providing quantitative assessment of a variety of cell biological characteristics of any adherent growing cell type in an automated and continuous fashion. PMID:26637177
ASRDI oxygen technology survey. Volume 8: Pressure measurement
NASA Technical Reports Server (NTRS)
Arvidson, J. M.; Brennan, J. A.
1975-01-01
Pressure transducers and their current uses with gaseous or liquid oxygen are reviewed. All transducer types such as strain gage, capacitance, potentiometric, piezoelectric, etc., are included. Topics covered include: cryogenic pressure measurement; material compatibility with gaseous and liquid oxygen; cleaning procedures; pressure tap connections; transducer types and descriptions; and calibration techniques.
A unified approach to fluid-flow, geomechanical, and seismic modelling
NASA Astrophysics Data System (ADS)
Yarushina, Viktoriya; Minakov, Alexander
2016-04-01
The perturbations of pore pressure can generate seismicity. This is supported by observations from human activities that involve fluid injection into rocks at high pressure (hydraulic fracturing, CO2 storage, geothermal energy production) and natural examples such as volcanic earthquakes. Although the seismic signals that emerge during geotechnical operations are small both in amplitude and duration when compared to natural counterparts. A possible explanation for the earthquake source mechanism is based on a number of in situ stress measurements suggesting that the crustal rocks are close to its plastic yield limit. Hence, a rapid increase of the pore pressure decreases the effective normal stress, and, thus, can trigger seismic shear deformation. At the same time, little attention has been paid to the fact that the perturbation of fluid pressure itself represents an acoustic source. Moreover, non-double-couple source mechanisms are frequently reported from the analysis of microseismicity. A consistent formulation of the source mechanism describing microseismic events should include both a shear and isotropic component. Thus, improved understanding of the interaction between fluid flow and seismic deformation is needed. With this study we aim to increase the competence in integrating real-time microseismic monitoring with geomechanical modelling such that there is a feedback loop between monitored deformation and stress field modelling. We propose fully integrated seismic, geomechanical and reservoir modelling. Our mathematical formulation is based on fundamental set of force balance, mass balance, and constitutive poro-elastoplastic equations for two-phase media consisting of deformable solid rock frame and viscous fluid. We consider a simplified 1D modelling setup for consistent acoustic source and wave propagation in poro-elastoplastic media. In this formulation the seismic wave is generated due to local changes of the stress field and pore pressure induced by e.g. fault generation or strain localization. This approach gives unified framework to characterize microseismicity of both class-I (pressure induced) and class-II (stress triggered) type of events. We consider two modelling setups. In the first setup the event is located within the reservoir and associated with pressure/stress drop due to fracture initiation. In the second setup we assume that seismic wave from a distant source hits a reservoir. The unified formulation of poro-elastoplastic deformation allows us to link the macroscopic stresses to local seismic instability.
Effects of a continuous lateral turning device on pressure relief.
Do, Nam Ho; Kim, Deog Young; Kim, Jung-Hoon; Choi, Jong Hyun; Joo, So Young; Kang, Na Kyung; Baek, Yoon Su
2016-01-01
[Purpose] The purpose of this study was to examine the pressure-relieving effects of a continuous lateral turning device on common pressure ulcer sites. [Subjects] Twenty-four healthy adults participated. [Methods] The design of our continuous lateral turning device was motivated by the need for an adequate pressure-relieving device for immobile and/or elderly people. The procedure of manual repositioning is embodied in our continuous lateral turning device. The interface pressure and time were measured, and comfort grade was evaluated during sessions of continuous lateral turning at 0°, 15°, 30°, and 45°. We quantified the pressure-relieving effect using peak pressure, mean pressure, and pressure time integration. [Results] Participants demonstrated pressure time integration values below the pressure-time threshold at 15°, 30°, and 45° at all the common pressure ulcer sites. Moreover, the most effective angles for pressure relief at the common pressure ulcer sites were 30° at the occiput, 15° at the left scapula, 45° at the right scapula, 45° at the sacrum, 15° at the right heel, and 30° at the left heel. However, angles greater than 30° induced discomfort. [Conclusion] Continuous lateral turning with our specially designed device effectively relieved the pressure of targeted sites. Moreover, the suggested angles of continuous lateral turning can be used to relieve pressure at targeted sites.
Integration of a supersonic unsteady aerodynamic code into the NASA FASTEX system
NASA Technical Reports Server (NTRS)
Appa, Kari; Smith, Michael J. C.
1987-01-01
A supersonic unsteady aerodynamic loads prediction method based on the constant pressure method was integrated into the NASA FASTEX system. The updated FASTEX code can be employed for aeroelastic analyses in subsonic and supersonic flow regimes. A brief description of the supersonic constant pressure panel method, as applied to lifting surfaces and body configurations, is followed by a documentation of updates required to incorporate this method in the FASTEX code. Test cases showing correlations of predicted pressure distributions, flutter solutions, and stability derivatives with available data are reported.
Human-in-the-Loop Integrated Life Support Systems Ground Testing
NASA Technical Reports Server (NTRS)
Henninger, Donald L.; Marmolejo, Jose A.; Westheimer, David T.
2011-01-01
Human exploration missions beyond low earth orbit will be long duration with abort scenarios of days to months. This necessitates provisioning the crew with all the things they will need to sustain themselves while carrying out mission objectives. Systems engineering and integration is critical to the point where extensive integrated testing of life support systems on the ground is required to identify and mitigate risks. Ground test facilities (human-rated altitude chamber) at the Johnson Space Center are being readied to integrate all the systems for a mission along with a human test crew. The relevant environment will include deep space habitat human accommodations, sealed atmosphere of 8 psi total pressure and 32% oxygen concentration, life support systems (food, air, water), communications, crew accommodations, medical, EVA, tools, etc. Testing periods will approximate those of the expected missions (such as a near Earth asteroid, Earth-Moon L2 or L1, the moon). This type of integrated testing is needed for research and technology development as well as later during the mission design, development, test, and evaluation (DDT&E) phases of an approved program. Testing will evolve to be carried out at the mission level fly the mission on the ground . Mission testing will also serve to inform the public and provide the opportunity for active participation by international partners.
On sorption and swelling of CO 2 in clays
Busch, A.; Bertier, P.; Gensterblum, Y.; ...
2016-03-23
One well-studied technology is the geological storage of carbon dioxide (CO 2), and a number of demonstration projects around the world have proven its feasibility and challenges. Storage conformance and seal integrity are among the most important aspects, as they determine risk of leakage as well as limits for storage capacity and injectivity. By providing evidence for safe storage is critical for improving public acceptance. Most caprocks are composed of clays as dominant mineral type which can typically be illite, kaolinite, chlorite or smectite. A number of recent studies addressed the interaction between CO 2 and these different clays andmore » it was shown that clay minerals adsorb considerable quantities of CO 2. For smectite this uptake can lead to volumetric expansion followed by the generation of swelling pressures. On the one hand CO 2 adsorption traps CO 2, on the other hand swelling pressures can potentially change local stress regimes and in unfavourable situations shear-type failure is assumed to occur. Moreover, for storage in a reservoir having high clay contents the CO 2 uptake can add to storage capacity which is widely underestimated so far. Smectite-rich seals in direct contact with a dry CO 2 plume at the interface to the reservoir might dehydrate leading to dehydration cracks. Such dehydration cracks can provide pathways for CO 2 ingress and further accelerate dewatering and penetration of the seal by supercritical CO 2. At the same time, swelling may also lead to the closure of fractures or the reduction of fracture apertures, thereby improving seal integrity. Finally, the goal of this communication is to theoretically evaluate and discuss these scenarios in greater detail in terms of phenomenological mechanisms, but also in terms of potential risks or benefits for carbon storage.« less
Tank System Integrated Model: A Cryogenic Tank Performance Prediction Program
NASA Technical Reports Server (NTRS)
Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Sutherlin, S. G.; Schnell, A. R.; Moder, J. P.
2017-01-01
Accurate predictions of the thermodynamic state of the cryogenic propellants, pressurization rate, and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning for future space exploration missions. This Technical Memorandum (TM) presents the analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, mixing, and condensation on the tank wall. This TM also includes comparisons of TankSIM program predictions with the test data andexamples of multiphase mission calculations.
Structural integrated sensor and actuator systems for active flow control
NASA Astrophysics Data System (ADS)
Behr, Christian; Schwerter, Martin; Leester-Schädel, Monika; Wierach, Peter; Dietzel, Andreas; Sinapius, Michael
2016-04-01
An adaptive flow separation control system is designed and implemented as an essential part of a novel high-lift device for future aircraft. The system consists of MEMS pressure sensors to determine the flow conditions and adaptive lips to regulate the mass flow and the velocity of a wall near stream over the internally blown Coanda flap. By the oscillating lip the mass flow in the blowing slot changes dynamically, consequently the momentum exchange of the boundary layer over a high lift flap required mass flow can be reduced. These new compact and highly integrated systems provide a real-time monitoring and manipulation of the flow conditions. In this context the integration of pressure sensors into flow sensing airfoils of composite material is investigated. Mechanical and electrical properties of the integrated sensors are investigated under mechanical loads during tensile tests. The sensors contain a reference pressure chamber isolated to the ambient by a deformable membrane with integrated piezoresistors connected as a Wheatstone bridge, which outputs voltage signals depending on the ambient pressure. The composite material in which the sensors are embedded consists of 22 individual layers of unidirectional glass fiber reinforced plastic (GFRP) prepreg. The results of the experiments are used for adapting the design of the sensors and the layout of the laminate to ensure an optimized flux of force in highly loaded structures primarily for future aeronautical applications. It can be shown that the pressure sensor withstands the embedding process into fiber composites with full functional capability and predictable behavior under stress.
NASA Astrophysics Data System (ADS)
Antony, Joby; Mathuria, D. S.; Chaudhary, Anup; Datta, T. S.; Maity, T.
2017-02-01
Cryogenic network for linear accelerator operations demand a large number of Cryogenic sensors, associated instruments and other control-instrumentation to measure, monitor and control different cryogenic parameters remotely. Here we describe an alternate approach of six types of newly designed integrated intelligent cryogenic instruments called device-servers which has the complete circuitry for various sensor-front-end analog instrumentation and the common digital back-end http-server built together, to make crateless PLC-free model of controls and data acquisition. These identified instruments each sensor-specific viz. LHe server, LN2 Server, Control output server, Pressure server, Vacuum server and Temperature server are completely deployed over LAN for the cryogenic operations of IUAC linac (Inter University Accelerator Centre linear Accelerator), New Delhi. This indigenous design gives certain salient features like global connectivity, low cost due to crateless model, easy signal processing due to integrated design, less cabling and device-interconnectivity etc.
Continuous thermal hydrolysis and energy integration in sludge anaerobic digestion plants.
Fdz-Polanco, F; Velazquez, R; Perez-Elvira, S I; Casas, C; del Barrio, D; Cantero, F J; Fdz-Polanco, M; Rodriguez, P; Panizo, L; Serrat, J; Rouge, P
2008-01-01
A thermal hydrolysis pilot plant with direct steam injection heating was designed and constructed. In a first period the equipment was operated in batch to verify the effect of sludge type, pressure and temperature, residence time and solids concentration. Optimal operation conditions were reached for secondary sludge at 170 degrees C, 7 bar and 30 minutes residence time, obtaining a disintegration factor higher than 10, methane production increase by 50% and easy centrifugation In a second period the pilot plant was operated working with continuous feed, testing the efficiency by using two continuous anaerobic digester operating in the mesophilic and thermophilic range. Working at 12 days residence time, biogas production increases by 40-50%. Integrating the energy transfer it is possible to design a self-sufficient system that takes advantage of this methane increase to produce 40% more electric energy. (c) IWA Publishing 2008.
NASA Astrophysics Data System (ADS)
Smith, R. K.; Ungers, L. J.
1984-07-01
A walk through survey of the integrated circuit fabrication operation revealed that engineering controls consisted of general and local ventilation, and isolation enclosure of the epitaxy and gas cylinder storage areas. The gas storage room was maintained at a slight negative pressure and gas monitoring was conducted. Liquid wastes were segregated according to type. Acidic wastes were pumped to a drain that carried them to a waste treatment system where they were neutralized with sodium hydroxide. Organic wastes were placed in containers which were taken to an outdoor area behind the facility where they were emptied into drums for disposal. The facility had no routine industrial hygiene program. Smocks, gloves, and safety glasses were required in all fabrication areas. Respirators were available in case of emergency. Preplacement medical examinations were not administered. Quarterly urinalyses for arsenic (7440382) exposure were conducted on all employees performing sawing operations.
High-pressure phases transitions in SnO2 to 117 GPa: Implications for silica
NASA Astrophysics Data System (ADS)
Shieh, S. R.; Kubo, A.; Duffy, T. S.; Prakapenka, V. B.; Shen, G.
2005-12-01
Cassiterite (SnO2) is regarded to be a good analog material for silica as both SnO2 and SiO2 are group IV-B metal dioxides. The high-pressure behavior of SnO2 has been the subject of many previous investigations extending up to 49 GPa and in addition to the rutile structure, three high-pressure phases, CaCl2-type, α-PbO2-type, and pyrite-type were observed. Better knowledge of high-pressure phases of SnO2 will be useful to understand the behavior of silica at deep mantle conditions. In addition, high-pressure metal dioxide phases may qualify as superhard solids. Our study will also provide insights into interpretation of shock compression data. Pure natural cassiterite (SnO2) powder was compressed in a diamond anvil cell using an argon medium. Pressure was determined from the equation of state of platinum. In situ monochromatic x-ray diffraction at high pressure was carried out at the GSECARS, Advanced Photon Source. High temperatures were achieved using double-sided laser heating . Three heating cycles were conducted with total heating times up to 30 minutes. Our diffraction results on SnO2 demonstrate the existence of four phase transitions to 117 GPa. The observed sequence of high-pressure phases for SnO2 is rutile-type, CaCl2-type, pyrite-type, ZrO2 orthorhombic phase I (Pbca), cotunnite-type. Our observations of the first three phases are generally in agreement with earlier studies. The orthorhombic phase I and cotunnite-type structures were observed in SnO2 for the first time. The Pbca phase is found at 50-74 GPa during room-temperature compression. The cotunnite-type structure was synthesized when SnO2 was heated at 74 GPa and 1200 K. The cotunnite-type form was observed during compression between 54-117 GPa. Fitting the pressure-volume data for the high-pressure phases to the second-order Birch-Murnaghan equation of state yields a bulk modulus of 259(26) GPa for the Pbca phase and 417(7) GPa for the cotunnite-type phase. Rietveld profile refinements were also carried out successfully for these two phases.
Integrated LTCC pressure/flow/temperature multisensor for compressed air diagnostics.
Fournier, Yannick; Maeder, Thomas; Boutinard-Rouelle, Grégoire; Barras, Aurélie; Craquelin, Nicolas; Ryser, Peter
2010-01-01
We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues.
Integrated LTCC Pressure/Flow/Temperature Multisensor for Compressed Air Diagnostics†
Fournier, Yannick; Maeder, Thomas; Boutinard-Rouelle, Grégoire; Barras, Aurélie; Craquelin, Nicolas; Ryser, Peter
2010-01-01
We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues. PMID:22163518
Improving the result of forcasting using reservoir and surface network simulation
NASA Astrophysics Data System (ADS)
Hendri, R. S.; Winarta, J.
2018-01-01
This study was aimed to get more representative results in production forcasting using integrated simulation in pipeline gathering system of X field. There are 5 main scenarios which consist of the production forecast of the existing condition, work over, and infill drilling. Then, it’s determined the best development scenario. The methods of this study is Integrated Reservoir Simulator and Pipeline Simulator so-calle as Integrated Reservoir and Surface Network Simulation. After well data result from reservoir simulator was then integrated with pipeline networking simulator’s to construct a new schedule, which was input for all simulation procedure. The well design result was done by well modeling simulator then exported into pipeline simulator. Reservoir prediction depends on the minimum value of Tubing Head Pressure (THP) for each well, where the pressure drop on the Gathering Network is not necessary calculated. The same scenario was done also for the single-reservoir simulation. Integration Simulation produces results approaching the actual condition of the reservoir and was confirmed by the THP profile, which difference between those two methods. The difference between integrated simulation compared to single-modeling simulation is 6-9%. The aimed of solving back-pressure problem in pipeline gathering system of X field is achieved.
NASA Astrophysics Data System (ADS)
Zhang, Qiang; Ma, XinCheng; Tie, Xuexi; Huang, Mengyu; Zhao, Chunsheng
In this study, aerosol vertical distributions of 17 in-situ aircraft measurements during 2005 and 2006 springs are analyzed. The 17 flights are carefully selected to exclude dust events, and the analyses are focused on the vertical distributions of aerosol particles associated with anthropogenic activities. The results show that the vertical distributions of aerosol particles are strongly affected by weather and meteorological conditions, and 3 different types of aerosol vertical distributions corresponding to different weather systems are defined in this study. The measurement with a flat vertical gradient and low surface aerosol concentrations is defined as type-1; a gradual decrease of aerosols with altitudes and modest surface aerosol concentrations is defined as type-2; a sharp vertical gradient (aerosols being strongly depressed in the PBL) with high surface aerosol concentrations is defined as type-3. The weather conditions corresponding to the 3 different aerosol types are high pressure, between two high pressures, and low pressure systems (frontal inversions), respectively. The vertical mixing and horizontal transport for the 3 different vertical distributions are analyzed. Under the type-1 condition, the vertical mixing and horizontal transport were rapid, leading to strong dilution of aerosols in both vertical and horizontal directions. As a result, the aerosol concentrations in PBL (planetary boundary layer) were very low, and the vertical distribution was flat. Under the type-2 condition, the vertical mixing was strong and there was no strong barrier at the PBL height. The horizontal transport (wind flux) was modest. As a result, the aerosol concentrations were gradually reduced with altitude, with modest surface aerosol concentrations. Under the type-3 condition, there was a cold front near the region. As a result, a frontal inversion associated with weak vertical mixing appeared at the top of the inversion layer, forming a very strong barrier to prevent aerosol particles being exchanged from the PBL height to the free troposphere. As a result, the aerosol particles were strongly depressed in the PBL height, producing high surface aerosol concentrations. The measured vertical aerosol distributions have important implications for studying the effects of aerosols on photochemistry. The J[O 3] values are reduced by 11%, 48%, and 50%, under the type-1, type-2, and type-3 conditions, respectively. This result reveals that atmospheric oxidant capacity (OH concentrations) is modestly reduced under the type-1 condition, but is significantly reduced under the type-2 and type-3 conditions. This result also suggests that the effect of aerosol particles on surface solar flux is an integrated column effect, and detailed vertical distributions of aerosol particles are very important for assessing the impacts of aerosol on photochemistry.
Energy efficient engine: Turbine transition duct model technology report
NASA Technical Reports Server (NTRS)
Leach, K.; Thurlin, R.
1982-01-01
The Low-Pressure Turbine Transition Duct Model Technology Program was directed toward substantiating the aerodynamic definition of a turbine transition duct for the Energy Efficient Engine. This effort was successful in demonstrating an aerodynamically viable compact duct geometry and the performance benefits associated with a low camber low-pressure turbine inlet guide vane. The transition duct design for the flight propulsion system was tested and the pressure loss goal of 0.7 percent was verified. Also, strut fairing pressure distributions, as well as wall pressure coefficients, were in close agreement with analytical predictions. Duct modifications for the integrated core/low spool were also evaluated. The total pressure loss was 1.59 percent. Although the increase in exit area in this design produced higher wall loadings, reflecting a more aggressive aerodynamic design, pressure profiles showed no evidence of flow separation. Overall, the results acquired have provided pertinent design and diagnostic information for the design of a turbine transition duct for both the flight propulsion system and the integrated core/low spool.
Stretchable Optomechanical Fiber Sensors for Pressure Determination in Compressive Medical Textiles.
Sandt, Joseph D; Moudio, Marie; Clark, J Kenji; Hardin, James; Argenti, Christian; Carty, Matthew; Lewis, Jennifer A; Kolle, Mathias
2018-05-29
Medical textiles are widely used to exert pressure on human tissues during treatment of post-surgical hematoma, burn-related wounds, chronic venous ulceration, and other maladies. However, the inability to dynamically sense and adjust the applied pressure often leads to suboptimal pressure application, prolonging treatment or resulting in poor patient outcomes. Here, a simple strategy for measuring sub-bandage pressure by integrating stretchable optomechanical fibers into elastic bandages is demonstrated. Specifically, these fibers possess an elastomeric photonic multilayer cladding that surrounds an extruded stretchable core filament. They can sustain repetitive strains of over 100%, and respond to deformation with a predictable and reversible color variation. Integrated into elastic textiles, which apply pressure as a function of their strain, these fibers can provide instantaneous and localized pressure feedback. These colorimetric fiber sensors are well suited for medical textiles, athletic apparel, and other smart wearable technologies, especially when repetitive, large deformations are required. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Path-integral simulation of ice Ih: The effect of pressure
NASA Astrophysics Data System (ADS)
Herrero, Carlos P.; Ramírez, Rafael
2011-12-01
The effect of pressure on structural and thermodynamic properties of ice Ih has been studied by means of path-integral molecular dynamics simulations at temperatures between 50 and 300 K. Interatomic interactions were modeled by using the effective q-TIP4P/F potential for flexible water. Positive (compression) and negative (tension) pressures have been considered, which allowed us to approach the limits for the mechanical stability of this solid water phase. We have studied the pressure dependence of the crystal volume, bulk modulus, interatomic distances, atomic delocalization, and kinetic energy. The spinodal point at both negative and positive pressures is derived from the vanishing of the bulk modulus. For P<0, the spinodal pressure changes from -1.38 to - 0.73 GPa in the range from 50 to 300 K. At positive pressure the spinodal is associated with ice amorphization, and at low temperatures it is found to be between 1.1 and 1.3 GPa. Quantum nuclear effects cause a reduction of the metastability region of ice Ih.
Ceramic-to-Metal Joining for High Temperature, High Pressure Heat Exchangers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mako, Frederick; Mako III, Frederick
2016-12-05
Designed and tested silicon carbide to metal joining and silicon carbide joining technology under high temperature and high pressure conditions. Determined that the joints maintained integrity and remained helium gas tight. These joined parts have been tested for mechanical strength, fracture toughness and hermeticity. A component testing chamber was designed and built and used for testing the joint integrity.
Modelling gas dynamics in 1D ducts with abrupt area change
NASA Astrophysics Data System (ADS)
Menina, R.; Saurel, R.; Zereg, M.; Houas, L.
2011-09-01
Most gas dynamic computations in industrial ducts are done in one dimension with cross-section-averaged Euler equations. This poses a fundamental difficulty as soon as geometrical discontinuities are present. The momentum equation contains a non-conservative term involving a surface pressure integral, responsible for momentum loss. Definition of this integral is very difficult from a mathematical standpoint as the flow may contain other discontinuities (shocks, contact discontinuities). From a physical standpoint, geometrical discontinuities induce multidimensional vortices that modify the surface pressure integral. In the present paper, an improved 1D flow model is proposed. An extra energy (or entropy) equation is added to the Euler equations expressing the energy and turbulent pressure stored in the vortices generated by the abrupt area variation. The turbulent energy created by the flow-area change interaction is determined by a specific estimate of the surface pressure integral. Model's predictions are compared with 2D-averaged results from numerical solution of the Euler equations. Comparison with shock tube experiments is also presented. The new 1D-averaged model improves the conventional cross-section-averaged Euler equations and is able to reproduce the main flow features.
Forkel, Philipp; Reuter, Sven; Sprenker, Frederike; Achtnich, Andrea; Herbst, Elmar; Imhoff, Andreas; Petersen, Wolf
2015-01-01
Posterior lateral meniscus root tears (PLMRTs) affect the intra-articular pressure distribution in the lateral compartment of the knee. The biomechanical consequences of these injuries are significantly influenced by the integrity of the meniscofemoral ligaments (MFLs). A newly introduced arthroscopic classification system for PLMRTs that takes MFL integrity into account has not yet been clinically applied but may be useful in selecting the optimal method of PLMRT repair. Prospective ACL reconstruction data were collected. Concomitant injuries of the lateral meniscus posterior horn were classified according to their shape and MFL status. The classifications were: type 1, avulsion of the root; type 2, radial tear of the lateral meniscus posterior horn close to the root with an intact MFL; and type 3, complete detachment of the posterior meniscus horn. Between January 2011 and May 2012, 228 consecutive ACL reconstructions were included. Lateral and medial meniscus tears were identified in 38.2% (n = 87) and 44.7% (n = 102), respectively. Of the 87 lateral meniscus tears, 32 cases had PLMRTs; the overall prevalence of PLMRTs was 14% (n = 32). Two medial meniscus root tears were detected. All PLMRTs were classified according to the classification system described above, and the fixation procedure was adapted to the type of meniscus tear. The PLMRT tear is a common injury among patients undergoing ACL repair and can be arthroscopically classified into three different types. Medial meniscus root tears are rare in association with ACL tears. The PLMRT classification presented here may help to estimate the injury's impact on the lateral compartment and to identify the optimal treatment. These tears should not be overlooked, and the treatment strategy should be chosen with respect to the type of root tear. IV.
Xu, Wei-Hua; Shen, Hua-Hao
2010-02-25
When using pressure-type plethysmography to test lung function of rodents, calculation of lung volume is always based on Boyle's law. The precondition of Boyle's law is that perfect air is static. However, air in the chamber is flowing continuously when a rodent breathes inside the chamber. Therefore, Boyle's law, a principle of air statics, may not be appropriate for measuring pressure changes of flowing air. In this study, we deduced equations for pressure changes inside pressure-type plethysmograph and then designed three experiments to testify the theoretic deduction. The results of theoretic deduction indicated that increased pressure was generated from two sources: one was based on Boyle's law, and the other was based on the law of conservation of momentum. In the first experiment, after injecting 0.1 mL, 0.2 mL, 0.4 mL of air into the plethysmograph, the pressure inside the chamber increased sharply to a peak value, then promptly decreased to horizontal pressure. Peak values were significantly higher than the horizontal values (P<0.001). This observation revealed that flowing air made an extra effect on air pressure in the plethysmograph. In the second experiment, the same volume of air was injected into the plethysmograph at different frequencies (0, 0.5, 1, 2, 3 Hz) and pressure changes inside were measured. The results showed that, with increasing frequencies, the pressure changes in the chamber became significantly higher (P<0.001). In the third experiment, small animal ventilator and pipette were used to make two types of airflow with different functions of time. The pressure changes produced by the ventilator were significantly greater than those produced by the pipette (P<0.001). Based on the data obtained, we draw the conclusion that, the flow of air plays a role in pressure changes inside the plethysmograph, and the faster the airflow is, the higher the pressure changes reach. Furthermore, the type of airflow also influences the pressure changes.
Integrated Main Propulsion System Performance Reconstruction Process/Models
NASA Technical Reports Server (NTRS)
Lopez, Eduardo; Elliott, Katie; Snell, Steven; Evans, Michael
2013-01-01
The Integrated Main Propulsion System (MPS) Performance Reconstruction process provides the MPS post-flight data files needed for postflight reporting to the project integration management and key customers to verify flight performance. This process/model was used as the baseline for the currently ongoing Space Launch System (SLS) work. The process utilizes several methodologies, including multiple software programs, to model integrated propulsion system performance through space shuttle ascent. It is used to evaluate integrated propulsion systems, including propellant tanks, feed systems, rocket engine, and pressurization systems performance throughout ascent based on flight pressure and temperature data. The latest revision incorporates new methods based on main engine power balance model updates to model higher mixture ratio operation at lower engine power levels.
Plasma jet printing for flexible substrates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandhiraman, Ram P.; Singh, Eric; Diaz-Cartagena, Diana C.
2016-03-21
Recent interest in flexible electronics and wearable devices has created a demand for fast and highly repeatable printing processes suitable for device manufacturing. Robust printing technology is critical for the integration of sensors and other devices on flexible substrates such as paper and textile. An atmospheric pressure plasma-based printing process has been developed to deposit different types of nanomaterials on flexible substrates. Multiwalled carbon nanotubes were deposited on paper to demonstrate site-selective deposition as well as direct printing without any type of patterning. Plasma-printed nanotubes were compared with non-plasma-printed samples under similar gas flow and other experimental conditions and foundmore » to be denser with higher conductivity. The utility of the nanotubes on the paper substrate as a biosensor and chemical sensor was demonstrated by the detection of dopamine, a neurotransmitter, and ammonia, respectively.« less
Some ideas and opportunities concerning three-dimensional wind-tunnel wall corrections
NASA Technical Reports Server (NTRS)
Rubbert, P. E.
1982-01-01
Opportunities for improving the accuracy and reliability of wall corrections in conventional ventilated test sections are presented. The approach encompasses state-of-the-art technology in transonic computational methods combined with the measurement of tunnel-wall pressures. The objective is to arrive at correction procedures of known, verifiable accuracy that are practical within a production testing environment. It is concluded that: accurate and reliable correction procedures can be developed for cruise-type aerodynamic testing for any wall configuration; passive walls can be optimized for minimal interference for cruise-type aerodynamic testing (tailored slots, variable open area ratio, etc.); monitoring and assessment of noncorrectable interference (buoyancy and curvature in a transonic stream) can be an integral part of a correction procedure; and reasonably good correction procedures can probably be developd for complex flows involving extensive separation and other unpredictable phenomena.
Fu Shaw, Ling; Chang, Pao-Chu; Lee, Jung-Fen; Kung, Huei-Yu
2014-01-01
Purpose. To explore the context of incidence of and associated risk factors for pressure ulcers amongst the population of surgical patients. Methods. The initial study cohort was conducted with a total of 297 patients admitted to a teaching hospital for a surgical operation from November 14th to 27th 2006 in Taipei, Taiwan. The Braden scale, pressure ulcers record sheet, and perioperative patient outcomes free from signs and symptoms of injury related to positioning and related nursing interventions and activities were collected. Results. The incidence of immediate and thirty-minute-later pressure ulcers is 9.8% (29/297) and 5.1% (15/297), respectively. Using logistic regression model, the statistically significantly associated risk factors related to immediate and thirty-minute-later pressure ulcers include operation age, type of anesthesia, type of operation position, type of surgery, admission Braden score, and number of nursing intervention after adjustment for confounding factors. Conclusion. Admission Braden score and number of nursing intervention are well-established protected factors for the development of pressure ulcers. Our study shows that older operation age, type of anesthesia, type of operation position, and type of surgery are also associated with the development of pressure ulcers. PMID:25057484
NASA Technical Reports Server (NTRS)
Scardelletti, M.; Neudeck, P.; Spry, D.; Meredith, R.; Jordan, J.; Prokop, N.; Krasowski, M.; Beheim, G.; Hunter, G.
2017-01-01
This paper describes initial development and testing of a novel high temperature capacitive pressure sensor system. The pressure sensor system consists of two 4H-SiC 11-stage ring oscillators and a SiCN capacitive pressure sensor. One oscillator has the capacitive pressure sensor fixed at one node in its feedback loop and varies as a function of pressure and temperature while the other provides a pressure-independent reference frequency which can be used to temperature compensate the output of the first oscillator. A two-day repeatability test was performed up to 500C on the oscillators and the oscillator fundamental frequency changed by only 1. The SiCN capacitive pressure sensor was characterized at room temperature from 0 to 300 psi. The sensor had an initial capacitance of 3.76 pF at 0 psi and 1.75 pF at 300 psi corresponding to a 54 change in capacitance. The integrated pressure sensor system was characterized from 0 to 300 psi in steps of 50 psi over a temperature range of 25 to 500C. The pressure sensor system sensitivity was 0.113 kHzpsi at 25C and 0.026 kHzpsi at 500C.
Choi, Sungjoon; Lee, Haksue; Moon, Wonkyu
2010-09-01
Although an air-backed thin plate is an effective sound receiver structure, it is easily damaged via pressure unbalance caused by external hydrostatic pressure. To overcome this difficulty, a simple pressure-balancing module is proposed. Despite its small size and relative simplicity, with proper design and operation, micro-channel structure provides a solution to the pressure-balancing problem. If the channel size is sufficiently small, the gas-liquid interface may move back and forth without breach by the hydrostatic pressure since the surface tension can retain the interface surface continuously. One input port of the device is opened to an intermediate liquid, while the other port is connected to the air-backing chamber. As the hydrostatic pressure increases, the liquid in the micro-channel compresses the air, and the pressure in the backing chamber is then equalized to match the external hydrostatic pressure. To validate the performance of the proposed mechanism, a micro-channel prototype is designed and integrated with the piezoelectric micro-machined flexural sensor developed in our previous work. The working principle of the mechanism is experimentally verified. In addition, the effect of hydrostatic pressure on receiving sensitivity is evaluated and compared with predicted behavior.
Ocular response to environmental variations in contact lens wearers.
López-de la Rosa, Alberto; Martín-Montañez, Vicente; López-Miguel, Alberto; Fernández, Itziar; Calonge, Margarita; González-Méijome, José M; González-García, María J
2017-01-01
To assess the influence of different indoor environments simulated in an environmental chamber on soft contact lens (CL) wearers. Fifty-four CL wearers were grouped based on their symptoms while wearing their CLs. Subjects were fitted with two different CL types, conventional hydrogel (Omafilcon A) and silicone hydrogel (comfilcon A), and exposed to two controlled indoor environmental conditions, standard [50% relative humidity (RH), 23°C, 930 mb of atmospheric pressure] and adverse (in-flight air cabin environment: 5% RH, localised air flow, 23°C, 750 mb atmospheric pressure), for 90 min in an environmental chamber, making a total of four visits. Symptoms, tear osmolarity, pre-lens tear breakup time (PLBUT), phenol red thread test, visual acuity, bulbar and limbal hyperaemia, corneal and limbal staining, and CL dehydration were assessed using repeated measures analysis of variance. A linear mixed model was used to analyse the effect of environment, CL type, discomfort-based grouping, and time on blink rate. Environment was found to significantly (p ≤ 0.018) affect limbal and bulbar hyperaemia, PLBUT, tear osmolarity, and CL dehydration. Likewise, CL type significantly (p ≤ 0.04) affected nasal and total corneal staining, limbal conjunctival staining, CL dehydration, comfort, and blurred vision. The environment, CL type, and time had significant effects (p ≤ 0.0001) on the blink rate. Ocular surface integrity and blink rate in CL wearers depend on the environment CL users are exposed to, as well as on the soft CL type that they are wearing. Tight control of environmental conditions can contribute to a better understanding of CL-related discomfort. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Pressure-induced phase transition in GaN nanocrystals
NASA Astrophysics Data System (ADS)
Cui, Q.; Pan, Y.; Zhang, W.; Wang, X.; Zhang, J.; Cui, T.; Xie, Y.; Liu, J.; Zou, G.
2002-11-01
High-pressure in situ energy-dispersive x-ray diffraction experiments on GaN nanocrystals with 50 nm diameter have been carried out using a synchrotron x-ray source and a diamond-anvil cell up to about 79 GPa at room temperature. A pressure-induced first-order structural phase transition from the wurtzite-type structure to the rock-salt-type structure starts at about 48.8 GPa. The rock-salt-type phase persists to the highest pressure in our experimental range.
Numerical calculations of velocity and pressure distribution around oscillating airfoils
NASA Technical Reports Server (NTRS)
Bratanow, T.; Ecer, A.; Kobiske, M.
1974-01-01
An analytical procedure based on the Navier-Stokes equations was developed for analyzing and representing properties of unsteady viscous flow around oscillating obstacles. A variational formulation of the vorticity transport equation was discretized in finite element form and integrated numerically. At each time step of the numerical integration, the velocity field around the obstacle was determined for the instantaneous vorticity distribution from the finite element solution of Poisson's equation. The time-dependent boundary conditions around the oscillating obstacle were introduced as external constraints, using the Lagrangian Multiplier Technique, at each time step of the numerical integration. The procedure was then applied for determining pressures around obstacles oscillating in unsteady flow. The obtained results for a cylinder and an airfoil were illustrated in the form of streamlines and vorticity and pressure distributions.
Miyazaki, Yu; Komasawa, Nobuyasu; Fujiawara, Shunsuke; Majima, Nozomi; Tatsumi, Shinichi; Minami, Toshiaki
2015-02-01
BaCKGROUND: The present study aimed to compare nitrous oxide-mediated increases in cuff pressure between the disposable type air-Q (air-Q-DT) and re-use type air-Q (air-Q-RU) in a simulated adult airway model. Automated cuff pressure was adjusted to 10, 20, and 30 cmH2O. The air-Q-DT and air-Q-RU were exposed to 80% nitrous oxide and cuff pressure was measured 15 and 30 minutes later. Cuff pressure of the air-Q-DT was significantly lower than that of the air-Q-RU after 15 and 30 minutes, regardless of the initial pressure. The polyvinyl chloride-based air-Q-DT may be more effective than the silicon-based air-Q-RU in preventing hyperinflation of the tracheal tube cuff in response to nitrous oxide exposure.
An integrated CFD/experimental analysis of aerodynamic forces and moments
NASA Technical Reports Server (NTRS)
Melton, John E.; Robertson, David D.; Moyer, Seth A.
1989-01-01
Aerodynamic analysis using computational fluid dynamics (CFD) is most fruitful when it is combined with a thorough program of wind tunnel testing. The understanding of aerodynamic phenomena is enhanced by the synergistic use of both analysis methods. A technique is described for an integrated approach to determining the forces and moments acting on a wind tunnel model by using a combination of experimentally measured pressures and CFD predictions. The CFD code used was FLO57 (an Euler solver) and the wind tunnel model was a heavily instrumented delta wing with 62.5 deg of leading-edge sweep. A thorough comparison of the CFD results and the experimental data is presented for surface pressure distributions and longitudinal forces and moments. The experimental pressures were also integrated over the surface of the model and the resulting forces and moments are compared to the CFD and wind tunnel results. The accurate determination of various drag increments via the combined use of the CFD and experimental pressures is presented in detail.
Wauters, L; Van Oudenhove, L; Selleslagh, M; Vanuytsel, T; Boeckxstaens, G; Tack, J; Omari, T; Rommel, N
2014-01-01
Pneumatic dilation of the lower esophageal sphincter (LES) in achalasia has an unappreciated effect on upper esophageal sphincter (UES) function. We studied UES pressure patterns at baseline and alterations in UES parameters resulting from therapy. High-resolution manometry (HRM) tracings from 50 achalasia patients, seen at a tertiary center between January 2009 and July 2011, were reviewed. Manometric parameters studied were (i) LES: resting pressure (restP), 4-second integrated relaxation pressure (IRP4); (ii) UES: resting pressure (restP), minimal relaxation pressure (MRP), peak pressure (PP), relaxation interval (RI), intrabolus pressure (IBP), and deglutitive sphincter resistance (DSR). Mixed models analyses with LES and UES parameters as dependent variables and treatment stage as within-subject independent variable of interest were used. Correlations between treatment-induced changes in LES, UES, and esophageal body (EB) parameters were performed. Pre- and posttreatment HRM tracings were available from 50 patients (mean age 52.7 ± 18.6 years, 29 men). Upper esophageal sphincter parameters MRP (17.9 ± 1.2 vs 15.2 ± 0.9 mmHg; p = 0.02) and IBP (31.5 ± 1.5 vs 27.4 ± 1.2 mmHg; p = 0.009) were significantly reduced after initial balloon dilation and this effect was significant in type II achalasia (p = 0.002 and p = 0.0006). Peak pressure, RI, and DSR were not. The therapeutic effect on LES IRP4 correlated significantly with the change in UES MRP, statistically mediated by the change in EB deglutitive pressure (p = 0.004 and p = 0.0002). We present the first HRM study demonstrating that pneumatic dilation of the LES affects intraesophageal and UES pressures in patients with achalasia. © 2013 John Wiley & Sons Ltd.
Type 2 Diabetes Mellitus and Cardiovascular Disease: Genetic and Epigenetic Links.
De Rosa, Salvatore; Arcidiacono, Biagio; Chiefari, Eusebio; Brunetti, Antonio; Indolfi, Ciro; Foti, Daniela P
2018-01-01
Type 2 diabetes mellitus (DM) is a common metabolic disorder predisposing to diabetic cardiomyopathy and atherosclerotic cardiovascular disease (CVD), which could lead to heart failure through a variety of mechanisms, including myocardial infarction and chronic pressure overload. Pathogenetic mechanisms, mainly linked to hyperglycemia and chronic sustained hyperinsulinemia, include changes in metabolic profiles, intracellular signaling pathways, energy production, redox status, increased susceptibility to ischemia, and extracellular matrix remodeling. The close relationship between type 2 DM and CVD has led to the common soil hypothesis, postulating that both conditions share common genetic and environmental factors influencing this association. However, although the common risk factors of both CVD and type 2 DM, such as obesity, insulin resistance, dyslipidemia, inflammation, and thrombophilia, can be identified in the majority of affected patients, less is known about how these factors influence both conditions, so that efforts are still needed for a more comprehensive understanding of this relationship. The genetic, epigenetic, and environmental backgrounds of both type 2 DM and CVD have been more recently studied and updated. However, the underlying pathogenetic mechanisms have seldom been investigated within the broader shared background, but rather studied in the specific context of type 2 DM or CVD, separately. As the precise pathophysiological links between type 2 DM and CVD are not entirely understood and many aspects still require elucidation, an integrated description of the genetic, epigenetic, and environmental influences involved in the concomitant development of both diseases is of paramount importance to shed new light on the interlinks between type 2 DM and CVD. This review addresses the current knowledge of overlapping genetic and epigenetic aspects in type 2 DM and CVD, including microRNAs and long non-coding RNAs, whose abnormal regulation has been implicated in both disease conditions, either etiologically or as cause for their progression. Understanding the links between these disorders may help to drive future research toward an integrated pathophysiological approach and to provide future directions in the field.
Ushigome, Emi; Fukui, Michiaki; Hamaguchi, Masahide; Matsumoto, Shinobu; Mineoka, Yusuke; Nakanishi, Naoko; Senmaru, Takafumi; Yamazaki, Masahiro; Hasegawa, Goji; Nakamura, Naoto
2013-09-01
Recently, focus has been directed toward pulse pressure as a potentially independent risk factor for micro- and macrovascular disease. This study was designed to examine the relationship between pulse pressure taken at home and elevated albuminuria in patients with type 2 diabetes. This study is a post hoc analysis of a cross-sectional multicenter study. Home blood pressure measurements were performed for 14 consecutive days in 858 patients with type 2 diabetes. We investigated the relationship between systolic blood pressure or pulse pressure in the morning or in the evening and urinary albumin excretion using univariate and multivariate analyses. Furthermore, we measured area under the receiver-operating characteristic curve (AUC) to compare the ability to identify elevated albuminuria, defined as urinary albumin excretion equal to or more than 30 mg/g creatinine, of systolic blood pressure or pulse pressure. Morning systolic blood pressure (β=0.339, P<0.001) and morning pulse pressure (β=0.378, P<0.001) were significantly associated with logarithm of urinary albumin excretion independent of other potential co-factors. AUC for elevated albuminuria in morning systolic blood pressure and morning pulse pressure were 0.668 (0.632-0.705; P<0.001) and 0.694 (0.659-0.730; P<0.001), respectively. AUC of morning pulse pressure was significantly greater than that of morning systolic blood pressure (P=0.040). Our findings implicate that morning pulse pressure is associated with elevated albuminuria in patients with type 2 diabetes, which suggests that lowering morning pulse pressure could prevent the development and progression of diabetic nephropathy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Recent Advances in Flexible/Stretchable Supercapacitors for Wearable Electronics.
Li, La; Lou, Zheng; Chen, Di; Jiang, Kai; Han, Wei; Shen, Guozhen
2017-11-22
The popularization of personalized wearable devices has accelerated the development of flexible/stretchable supercapacitors (SCs) that possess remarkable features of miniaturization, high security, and easy integration to build an all-in-one integrated system, and realize the functions of comfortable, noninvasive and continuous health monitoring, motion records, and information acquisition, etc. This Review presents a brief phylogeny of flexible/stretchable SCs, represented by planar micro-supercapacitors (MSCs) and 1D fibrous SCs. The latest progress and advantages of different flexible/stretchable/self-healing substrate, solid-state electrolyte and electrode materials for the fabrication of wearable SCs devices are summarized. The various configurations used in planar MSCs and 1D fibrous SCs aiming at the improvement of performance are also discussed. In addition, from the viewpoint of practical value and large-scale production, a survey of integrated systems, from different types of SC powered wearable sensing (gas, pressure, tactile…) systems, wearable all-in-one systems (including energy harvest, storage, and functional groups), to device packaging is presented. Finally, the challenges and future perspectives of wearable SCs are also considered. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Jain, Aayushi; Dixit, R. C.
2018-05-01
Pressure induced structural phase transition of NaCl-type (B1) to CsCl-type (B2) structure in Sodium Chloride NaCl are presented. An effective interionic interaction potential (EIOP) with long range Coulomb, van der Waals (vdW) interaction and the short-range repulsive interaction upto second-neighbor ions within the Hafemeister and Flygare approach with modified ionic charge is reported here. The reckon value of the phase transition pressure (Pt) and the magnitude of the discontinuity in volume at the transition pressure are compatible as compared with reported data. The variations of elastic constants and their combinations with pressure follow ordered behavior. The present approach has also succeeded in predicting the Born and relative stability criteria.
Investigations on the self-excited oscillations in a kerosene spray flame
DOE Office of Scientific and Technical Information (OSTI.GOV)
de la Cruz Garcia, M.; Mastorakos, E.; Dowling, A.P.
2009-02-15
A laboratory scale gas turbine type burner at atmospheric pressure and with air preheat was operated with aviation kerosene Jet-A1 injected from a pressure atomiser. Self-excited oscillations were observed and analysed to understand better the relationship between the spray and thermo-acoustic oscillations. The fluctuations of CH{sup *} chemiluminescence measured simultaneously with the pressure were used to determine the flame transfer function. The Mie scattering technique was used to record spray fluctuations in reacting conditions with a high speed camera. Integrating the Mie intensity over the imaged region gave a temporal signal acquired simultaneously with pressure fluctuations and the transfer functionmore » between the light scattered from the spray and the velocity fluctuations in the plenum was evaluated. Phase Doppler anemometry was used for axial velocity and drop size measurements at different positions downstream the injection plane and for various operating conditions. Pressure spectra showed peaks at a frequency that changed with air mass flow rate. The peak for low air mass flow rate operation was at 220 Hz and was associated with a resonance of the supply plenum. At the same global equivalence ratio but at high air mass flow rates, the pressure spectrum peak was at 323 Hz, a combustion chamber resonant frequency. At low air flow rates, the spray fluctuation motion was pronounced and followed the frequency of the pressure oscillation. At high air flow rates, more effective evaporation resulted in a complete disappearance of droplets at an axial distance of about 1/3 burner diameters from the injection plane, leading to a different flame transfer function and frequency of the self-excited oscillation. The results highlight the sensitivity of the self-excited oscillation to the degree of mixing achieved before the main recirculation zone. (author)« less
An algorithm to estimate unsteady and quasi-steady pressure fields from velocity field measurements.
Dabiri, John O; Bose, Sanjeeb; Gemmell, Brad J; Colin, Sean P; Costello, John H
2014-02-01
We describe and characterize a method for estimating the pressure field corresponding to velocity field measurements such as those obtained by using particle image velocimetry. The pressure gradient is estimated from a time series of velocity fields for unsteady calculations or from a single velocity field for quasi-steady calculations. The corresponding pressure field is determined based on median polling of several integration paths through the pressure gradient field in order to reduce the effect of measurement errors that accumulate along individual integration paths. Integration paths are restricted to the nodes of the measured velocity field, thereby eliminating the need for measurement interpolation during this step and significantly reducing the computational cost of the algorithm relative to previous approaches. The method is validated by using numerically simulated flow past a stationary, two-dimensional bluff body and a computational model of a three-dimensional, self-propelled anguilliform swimmer to study the effects of spatial and temporal resolution, domain size, signal-to-noise ratio and out-of-plane effects. Particle image velocimetry measurements of a freely swimming jellyfish medusa and a freely swimming lamprey are analyzed using the method to demonstrate the efficacy of the approach when applied to empirical data.
Transducer Modules for Dry-Coupled Ultrasonic Inspection of Aircraft Structures
NASA Astrophysics Data System (ADS)
Komsky, Igor N.
2004-02-01
Several types of transducer modules have been developed at Northwestern University to overcome the problems that are associated with the application of liquid or gel couplants. The modules deploy polymer films to transmit the ultrasound through a dry interface. These films are very flexible, so even with a low pressure they can be adapted to the irregular inspection surfaces. The dry-coupled transducer modules may be used for transmission and reception of both longitudinal and transverse ultrasonic waves in the MHz frequency range. The prototype modules have been integrated with the portable ultrasonic inspection units and tested on a number of aircraft structures.
Accurate green water loads calculation using naval hydro pack
NASA Astrophysics Data System (ADS)
Jasak, H.; Gatin, I.; Vukčević, V.
2017-12-01
An extensive verification and validation of Finite Volume based CFD software Naval Hydro based on foam-extend is presented in this paper for green water loads. Two-phase numerical model with advanced methods for treating the free surface is employed. Pressure loads on horizontal deck of Floating Production Storage and Offloading vessel (FPSO) model are compared to experimental results from [1] for three incident regular waves. Pressure peaks and integrals of pressure in time are measured on ten different locations on deck for each case. Pressure peaks and integrals are evaluated as average values among the measured incident wave periods, where periodic uncertainty is assessed for both numerical and experimental results. Spatial and temporal discretization refinement study is performed providing numerical discretization uncertainties.
Chen, Wenjun; Gui, Xuchun; Liang, Binghao; Yang, Rongliang; Zheng, Yongjia; Zhao, Chengchun; Li, Xinming; Zhu, Hai; Tang, Zikang
2017-07-19
Nature-motivated pressure sensors have been greatly important components integrated into flexible electronics and applied in artificial intelligence. Here, we report a high sensitivity, ultrathin, and transparent pressure sensor based on wrinkled graphene prepared by a facile liquid-phase shrink method. Two pieces of wrinkled graphene are face to face assembled into a pressure sensor, in which a porous anodic aluminum oxide (AAO) membrane with the thickness of only 200 nm was used to insulate the two layers of graphene. The pressure sensor exhibits ultrahigh operating sensitivity (6.92 kPa -1 ), resulting from the insulation in its inactive state and conduction under compression. Formation of current pathways is attributed to the contact of graphene wrinkles through the pores of AAO membrane. In addition, the pressure sensor is also an on/off and energy saving device, due to the complete isolation between the two graphene layers when the sensor is not subjected to any pressure. We believe that our high-performance pressure sensor is an ideal candidate for integration in flexible electronics, but also paves the way for other 2D materials to be involved in the fabrication of pressure sensors.
NASA Astrophysics Data System (ADS)
Kunimoto, Takehiro; Irifune, Tetsuo; Tange, Yoshinori; Wada, Kouhei
2016-04-01
A pressure generation test for Kawai-type multianvil apparatus (KMA) has been made using second-stage anvils of a newly developed ultra-hard tungsten carbide composite. Superb performance of the new anvil with significantly less plastic deformation was confirmed as compared to those commonly used for the KMA experiments. A maximum pressure of ∼48 GPa was achieved using the new anvils with a truncation edge length (TEL) of 1.5 mm, based on in situ X-ray diffraction measurements. Further optimization of materials and sizes of the pressure medium/gasket should lead to pressures even higher than 50 GPa in KMA using this novel tungsten carbide composite, which may also be used for expansion of the pressure ranges in other types of high pressure apparatus operated in large volume press.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorin Zaharia; C.Z. Cheng
In this paper, we study whether the magnetic field of the T96 empirical model can be in force balance with an isotropic plasma pressure distribution. Using the field of T96, we obtain values for the pressure P by solving a Poisson-type equation {del}{sup 2}P = {del} {center_dot} (J x B) in the equatorial plane, and 1-D profiles on the Sun-Earth axis by integrating {del}P = J x B. We work in a flux coordinate system in which the magnetic field is expressed in terms of Euler potentials. Our results lead to the conclusion that the T96 model field cannot bemore » in equilibrium with an isotropic pressure. We also analyze in detail the computation of Birkeland currents using the Vasyliunas relation and the T96 field, which yields unphysical results, again indicating the lack of force balance in the empirical model. The underlying reason for the force imbalance is likely the fact that the derivatives of the least-square fitted model B are not accurate predictions of the actual magnetospheric field derivatives. Finally, we discuss a possible solution to the problem of lack of force balance in empirical field models.« less
NASA Technical Reports Server (NTRS)
Goradia, S. H.; Bobbitt, P. J.; Morgan, H. L.; Ferris, J. C.; Harvey, William D.
1989-01-01
Results of correlative and design studies for transition location, laminar and turbulent boundary-layer parameters, and wake drag for forward swept and aft swept wings are presented. These studies were performed with the use of an improved integral-type boundary-layer and transition-prediction methods. Theoretical predictions were compared with flight measurements at subsonic and transonic flow conditions for the variable aft swept wing F-14 aircraft for which experimental pressure distributions, transition locations, and turbulent boundary-layer velocity profiles were measured. Flight data were available at three spanwise stations for several values of sweep, freestream unit Reynolds number, Mach numbers, and lift coefficients. Theory/experiment correlations indicate excellent agreement for both transition location and turbulent boundary-layer parameters. The results of parametric studies performed during the design of a laminar glove for the forward swept wing X-29 aircraft are also presented. These studies include the effects of a spanwise pressure gradient on transition location and wake drag for several values of freestream Reynolds numbers at a freestream Mach number of 0.9.
Smart healthcare textile sensor system for unhindered-pervasive health monitoring
NASA Astrophysics Data System (ADS)
Rai, Pratyush; Kumar, Prashanth S.; Oh, Sechang; Kwon, Hyeokjun; Mathur, Gyanesh N.; Varadan, Vijay K.; Agarwal, M. P.
2012-04-01
Simultaneous monitoring of physiological parameters- multi-lead Electrocardiograph (ECG), Heart rate variability, and blood pressure- is imperative to all forms of medical treatments. Using an array of signal recording devices imply that the patient will have to be confined to a bed. Textiles offer durable platform for embedded sensor and communication systems. The smart healthcare textile, presented here, is a mobile system for remote/wireless data recording and conditioning. The wireless textile system has been designed to monitor a patient in a non-obstructive way. It has a potential for facilitating point of care medicine and streamlining ambulatory medicine. The sensor systems were designed and fabricated with textile based components for easy integration on textile platform. An innovative plethysmographic blood pressure monitoring system was designed and tested as an alternative to inflatable blood pressure sphygmomanometer. Flexible dry electrodes technology was implemented for ECG. The sensor systems were tested and conditioned to daily activities of patients, which is not permissible with halter type systems. The signal quality was assessed for it applicability to medical diagnosis. The results were used to corroborate smart textile sensor system's ability to function as a point of care system that can provide quality healthcare.
An Autonomous, Low Cost Platform for Seafloor Geodetic Observations
NASA Astrophysics Data System (ADS)
Ericksen, T.; Foster, J. H.; Bingham, B. S.
2013-12-01
The high cost of acquiring geodetic data from the sea floor has limited the observations available to help us understand and model the behavior of seafloor geodetic processes. To address this problem, the Pacific GPS Facility at the University of Hawaii is developing a cost effective approach for accurately measuring short-term vertical motions of the seafloor and maintaining a continuous long-term record of seafloor pressure without the requirement for costly ship time. There is a recognized need to vastly increase our underwater geodetic observing capacity. Most of the largest recorded earthquakes and most devastating tsunamis are generated at subduction zones underwater. Similarly, many volcanoes are partly (e.g. Santorini) or completely (e.g. Loihi) submerged, and are not well observed and understood. Furthermore, landslide features ring many ocean basins, and huge debris deposits surround many volcanic oceanic islands. Our approach will lower the cost of collecting sea-floor geodetic data, reducing the barriers preventing us from acquiring the information we need to observe and understand these types of structures and provide a direct societal benefit in improving hazard assessment. The capability is being developed by equipping one of the University of Hawaii Wave Gliders with an integrated acoustic telemetry package, a dual frequency geodetic-grade Global Positioning System (GPS) receiver, processing unit, and cellular communications. The Wave Glider will interrogate high accuracy pressure sensors on the sea floor to maintain a near-continuous stream of pressure and temperature data, but seafloor pressure data includes contribution from a variety of sources and on its own may not provide the accuracy required for geodetic investigations. Independent measurements of sea surface pressure and sea surface height can be used to remove these contributions from the observed sea floor pressure timeseries. We will integrate our seafloor pressure measurements with air pressure data, and precise vertical measurements of the sea surface from kinematic positioning of the Wave Glider over the bottom sensor, to determine cm-scale vertical seafloor motions. The seafloor package will consist of a simple tripod frame that seats the pressure sensor unit, and includes an attachment onto which an ROV can install a mobile pressure recorder (MPR) should ship and ROV time be available. Two visits with an MPR would allow calibration of the linear drift of the continuous sensor, further enhancing the value of the timeseries. The pressure sensor is recoverable and serviceable and using the MPR calibration will enable the seafloor monument to be re-occupied to extend the pressure record beyond a single 5+ year deployment. We are currently focused on retrieving high accuracy vertical sea floor motions, but, importantly, we have chosen a development approach that provides a simple upgrade path for incorporating the Wave Glider GPS-Acoustic (GPS/A) measurement system under development at SIO. With this upgrade, Wave Gliders could also acquire accurate horizontal motions of the sea floor sensors, and provide a cost-effective way of performing full, 3-dimensional, surveys of sea-floor motions.
NASA Astrophysics Data System (ADS)
Feddema, Rick
Feddema, Rick T. M.S.M.E., Purdue University, December 2013. Effect of Aviation Fuel Type and Fuel Injection Conditions on the Spray Characteristics of Pressure Swirl and Hybrid Air Blast Fuel Injectors. Major Professor: Dr. Paul E. Sojka, School of Mechanical Engineering Spray performance of pressure swirl and hybrid air blast fuel injectors are central to combustion stability, combustor heat management, and pollutant formation in aviation gas turbine engines. Next generation aviation gas turbine engines will optimize spray atomization characteristics of the fuel injector in order to achieve engine efficiency and emissions requirements. Fuel injector spray atomization performance is affected by the type of fuel injector, fuel liquid properties, fuel injection pressure, fuel injection temperature, and ambient pressure. Performance of pressure swirl atomizer and hybrid air blast nozzle type fuel injectors are compared in this study. Aviation jet fuels, JP-8, Jet A, JP-5, and JP-10 and their effect on fuel injector performance is investigated. Fuel injector set conditions involving fuel injector pressure, fuel temperature and ambient pressure are varied in order to compare each fuel type. One objective of this thesis is to contribute spray patternation measurements to the body of existing drop size data in the literature. Fuel droplet size tends to increase with decreasing fuel injection pressure, decreasing fuel injection temperature and increasing ambient injection pressure. The differences between fuel types at particular set conditions occur due to differences in liquid properties between fuels. Liquid viscosity and surface tension are identified to be fuel-specific properties that affect the drop size of the fuel. An open aspect of current research that this paper addresses is how much the type of aviation jet fuel affects spray atomization characteristics. Conventional aviation fuel specifications are becoming more important with new interest in alternative fuels. Optical patternation data and line of sight laser diffraction data show that there is significant difference between jet fuels. Particularly at low fuel injection pressures (0.345 MPa) and cold temperatures (-40 C), the patternation data shows that the total surface area in the spray at 38.1 mm from the pressure swirl injector for the JP-10 fuel type is one-sixth the amount of the JP-8. Finally, this study compares the atomizer performance of a pressure swirl nozzle to a hybrid air blast nozzle. The total surface area for both the hybrid air blast nozzle and the pressure swirl nozzle show a similar decline in atomization performance at low fuel injection pressures and cold temperatures. However, the optical patternator radial profile data and the line of sight laser diffraction data show that the droplet size and spray distribution data are less affected by injection conditions and fuel type in the hybrid air blast nozzle, than they are in the pressure swirl nozzle. One explanation is that the aerodynamic forces associated with the swirler on the hybrid air blast nozzle control the distribution droplets in the spray. This is in contrast to the pressure swirl nozzle droplet distribution that is controlled by internal geometry and droplet ballistics.
Hoshide, Satoshi; Yano, Yuichiro; Mizuno, Hiroyuki; Kanegae, Hiroshi; Kario, Kazuomi
2018-01-01
We assessed the relationship between day-by-day home blood pressure (BP) variability and incident cardiovascular disease (CVD) in clinical practice. J-HOP study (Japan Morning Surge-Home Blood Pressure) participants underwent home BP monitoring in the morning and evening for a 14-day period, and their BP levels and BP variability independent of the mean (VIM) were assessed. Incident CVD events included coronary heart disease and stroke. Cox models were fitted to assess the home BP variability-CVD risk association. Among 4231 participants (mean±SD age, 64.9±10.9 years; 53.3% women; 79.1% taking antihypertensive medication), mean (SD) home systolic BP (SBP) levels over time and VIM SBP were 134.2 (14.3) and 6.8 (2.5) mm Hg, respectively. During a 4-year follow-up period (16 750.3 person-years), 148 CVD events occurred. VIM SBP was associated with CVD risk (hazard ratio per 1-SD increase, 1.32; 95% confidence interval [CI], 1.15-1.52), independently of mean home SBP levels over time and circulating B-type natriuretic peptide levels or urine albumin-to-creatinine ratio. Adding VIM SBP to the CVD prediction model improved the discrimination (C statistic, 0.785 versus 0.770; C statistic difference, 0.015; 95% CI, 0.003-0.028). Changes in continuous net reclassification improvement (0.259; 95% CI, 0.052-0.537), absolute integrated discrimination improvement (0.010; 95% CI, 0.003-0.016), and relative integrated discrimination improvement (0.104; 95% CI, 0.037-0.166) were also observed with the addition of VIM SBP to the CVD prediction models. In addition to the assessments of mean home SBP levels and cardiovascular end-organ damage, home BP variability measurements may provide a clinically useful distinction between high- and low-risk groups among Japanese outpatients. © 2017 American Heart Association, Inc.
Pretreatment of high solid microbial sludges
Rivard, Christopher J.; Nagle, Nicholas J.
1998-01-01
A process and apparatus for pretreating microbial sludges in order to enhance secondary anaerobic digestion. The pretreatment process involves disrupting the cellular integrity of municipal sewage sludge through a combination of thermal, explosive decompression and shear forces. The sludge is pressurized and pumped to a pretreatment reactor where it is mixed with steam to heat and soften the sludge. The pressure of the sludge is suddenly reduced and explosive decompression forces are imparted which partially disrupt the cellular integrity of the sludge. Shear forces are then applied to the sludge to further disrupt the cellular integrity of the sludge. Disrupting cellular integrity releases both soluble and insoluble organic constituents and thereby renders municipal sewage sludge more amenable to secondary anaerobic digestion.
Effects of Age on Esophageal Motility: Use of High-resolution Esophageal Impedance Manometry
Shim, Young Kwang; Kim, Nayoung; Park, Yo Han; Lee, Jong-Chan; Sung, Jihee; Choi, Yoon Jin; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2017-01-01
Background/Aims Disturbances of esophageal motility have been reported to be more frequent the aged population. However, the physiology of disturbances in esophageal motility during aging is unclear. The aim of this study was to evaluate the effects of age on esophageal motility using high-resolution esophageal impedance manometry (HRIM). Methods Esophageal motor function of 268 subjects were measured using HRIM in 3 age groups, < 40 years (Group A, n = 32), 40–65 years (Group B, n = 185), and > 65 years (Group C, n = 62). Lower esophageal sphincter (LES) and upper esophageal sphincter (UES) pressures, integrated relaxation pressure, distal contractile integral, contractile front velocity, distal latency, and pressures and duration of contraction on 4 positions along the esophagus, and complete bolus transit were measured. Results Basal UES pressure was lower in Group C (P < 0.001) but there was no significant difference in the LES pressure among groups. Contractile duration on position 3 (10 cm from proximal LES high pressure zone) was longer in Group C (P = 0.001), and the contractile amplitude on position 4 (5 cm from proximal LES high pressure zone) was lower in Group C (P = 0.005). Distal contractile integral was lower in Group C (P = 0.037). Contractile front velocity (P = 0.015) and the onset velocity (P = 0.040) was lower in Group C. There was no significant difference in impedance values. Conclusions The decrease of UES pressure, distal esophageal motility, and peristaltic velocity might be related with esophageal symptoms in the aged population. PMID:28163259
NASA Astrophysics Data System (ADS)
Stam, Frank; Kuisma, Heikki; Gao, Feng; Saarilahti, Jaakko; Gomes Martins, David; Kärkkäinen, Anu; Marrinan, Brendan; Pintal, Sebastian
2017-05-01
The deadliest disease in the world is coronary artery disease (CAD), which is related to a narrowing (stenosis) of blood vessels due to fatty deposits, plaque, on the arterial walls. The level of stenosis in the coronary arteries can be assessed by Fractional Flow Reserve (FFR) measurements. This involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. The blood flow is represented by a pressure drop, thus a pressure wire or pressure sensor integrated in a catheter can be used to calculate the ratio between the coronary pressure distal to the stenosis and the normal coronary pressure. A 2 Fr (0.67mm) outer diameter catheter was used, which required a high level of microelectronics miniaturisation to fit a pressure sensing system into the outer wall. The catheter has an eccentric guidewire lumen with a diameter of 0.43mm, which implies that the thickest catheter wall section provides less than 210 microns height for flex assembly integration consisting of two dies, a capacitive MEMS pressure sensor and an ASIC. In order to achieve this a very thin circuit flex was used, and the two chips were thinned down to 75 microns and flip chip mounted face down on the flex. Many challenges were involved in obtaining a flex layout that could wrap into a small tube without getting the dies damaged, while still maintaining enough flexibility for the catheter to navigate the arterial system.
NASA Astrophysics Data System (ADS)
Kumar, Anuj; Yadav, Sanjay; Agarwal, Ravinder
2017-08-01
A number of pressure transducers, based on strain gauge, capacitance/inductance type, frequency resonators, are commercially available and are being used for sensing and producing an electrical output proportional to applied pressure. These sensors have their own advantages and limitations due to operational ease, measurement uncertainty and the costs. Strain gauge type transducers are now well established devices for accurate and precise measurement of pressure within measurement uncertainty up to 0.1 % of full scale. In the present research work, an indigenous strain gauge pressure transducer has been designed, developed, tested and calibrated for pressure measurement up to 200 MPa. The measurement uncertainty estimated using the pressure transducer was found better than 0.1 % of full scale. This transducer was developed using four foil type strain gauges, bonded, two in axial direction while other two in radial direction, to the controlled stress zones of a tubular maraging steel active cylinder working also as diaphragm. The strain gages were then connected to a Wheatstone bridge arrangement to measure stress generated strains. The pressure was applied through matching connector designed in the same tubular transducer active element. The threaded unique design in a single piece through collar, ferule and tubing arrangement provides leak proof pressure connections with external devices without using additional seals. The calibration and performance checking of the pressure transducer was carried out using dead weight type national pressure standard using the internationally accepted calibration procedure.
NASA Technical Reports Server (NTRS)
Wnuk, Michael P.
1997-01-01
The objective of this research work has been to provide analytical background and support to the ongoing experimental program at NASA, White Sands Test Facility, involving testing composite overwrapped pressure vessels (COPV) for impact damage and cyclic pressurization. Preliminary theoretical basis, including the governing equations for a shallow shell subjected to internal pressure, has been established. Effects of the Griffith type cracks on the structural integrity of the cylindrical vessel were evaluated by methods of Fracture Mechanics. The results indicate that the effective mass of the pressure vessel is an important factor influencing the response to impact events. We also have found that the material properties of the target, contained in the constitutive equations of the composite attached to the Aluminum liner, dominate the impact event in the low velocity range, the material properties become less important, while the target mass distribution and the impactor mass become more significant as the velocity of the impactor increases. Therefore, at high-velocity impact it is not only the kinetic energy of the impactor but also its mass which has a significant effect on the dynamics of the event, and consequently on the induced damage. This work also suggests a methodology for an assessment of the rate of loading effects on the degradation of the material toughness associated with a high-velocity impact where the rate effects become significant. To model the rate dependence of the material response a viscoelastic-plastic constitutive equations were assumed, and on this basis predictions are made regarding the rate dependent material resistance curve. Other dynamic phenomena associated with the impact event have been treated in the framework of the Computational Mechanics using the courtesy of Prof. P. Guebelle and his graduate student at University of Illinois at Urbana-Champaign who have an access to a super-fast computer located on their campus. Finally, the guidelines for a follow-up research program are provided in the body of this report. They address three major areas: theoretical research, numerical studies, and further experimental work.
46 CFR 119.435 - Integral fuel tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Integral fuel tanks. 119.435 Section 119.435 Shipping... Machinery Requirements § 119.435 Integral fuel tanks. (a) Diesel fuel tanks may not be built integral with... for certification of a vessel, integral fuel tanks must withstand a hydrostatic pressure test of 35 k...
46 CFR 119.435 - Integral fuel tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Integral fuel tanks. 119.435 Section 119.435 Shipping... Machinery Requirements § 119.435 Integral fuel tanks. (a) Diesel fuel tanks may not be built integral with... for certification of a vessel, integral fuel tanks must withstand a hydrostatic pressure test of 35 k...
Integration of fracturing dynamics and pressure transient analysis for hydraulic fracture evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arihara, N.; Abbaszadeh, M.; Wright, C.A.
This paper presents pre- and post-fracture pressure transient analysis, combined with net fracture pressure interpretation, for a well in a naturally fractured geothermal reservoir. Integrated analysis was performed to achieve a consistent interpretation of the created fracture geometry, propagation, conductivity, shrinkage, reservoir flow behavior, and formation permeability characteristics. The interpreted data includes two-rate pre-frac injection tests, step-rate injection tests, a series of pressure falloff tests, and the net fracturing pressure from a massive fracture treatment. Pressure transient analyses were performed utilizing advanced well test interpretation techniques and a thermal reservoir simulator with fracture propagation option. Hydraulic fracture propagation analysis wasmore » also performed Milt a generalized 3-D dynamic fracture growth model simulator. Three major conclusions resulted from the combined analysis: (1) that an increasing number of hydraulic fractures were being simultaneously propagated during the fracture treatment. (2) that the reservoir behaved as a composite reservoir Keith the outer region permeability being greater than the permeability of the region immediately surrounding the wellbore, and (3) that the created fractures extended into the outer region during the fracture treatment but retreated to the inner region several days after stimulation had ceased. These conclusions were apparent from independent pressure transient analysis and from independent hydraulic fracture propagation analysis. Integrated interpretation, however, increased the confidence in these conclusions and greatly aided the quantification of the created hydraulic fracture geometry and characterization of the reservoir permeability.« less
Analysis of the possibility of a PGA309 integrated circuit application in pressure sensors
NASA Astrophysics Data System (ADS)
Walendziuk, Wojciech; Baczewski, Michal; Idzkowski, Adam
2016-09-01
This article present the results of research concerning the analysis of the possibilities of applying a PGA309 integrated circuit in transducers used for pressure measurement. The experiments were done with the use of a PGA309EVM-USB evaluation circuit with a BD|SENSORS pressure sensor. A specially prepared MATLAB script was used in the process of the calibration setting choice and the results analysis. The article discusses the worked out algorithm that processes the measurement results, i.e. the algorithm which calculates the desired gain and the offset adjustment voltage of the transducer measurement bridge in relation to the input signal range of the integrated circuit and the temperature of the environment (temperature compensation). The checking procedure was conducted in a measurement laboratory and the obtained result were analyzed and discussed.
Canonical fluid thermodynamics
NASA Technical Reports Server (NTRS)
Schmid, L. A.
1972-01-01
The space-time integral of the thermodynamic pressure plays the role of the thermodynamic potential for compressible, adiabatic flow in the sense that the pressure integral for stable flow is less than for all slightly different flows. This stability criterion can be converted into a variational minimum principle by requiring the molar free-enthalpy and the temperature, which are the arguments of the pressure function, to be generalized velocities, that is, the proper-time derivatives of scalar spare-time functions which are generalized coordinates in the canonical formalism. In a fluid context, proper-time differentiation must be expressed in terms of three independent quantities that specify the fluid velocity. This can be done in several ways, all of which lead to different variants (canonical transformations) of the same constraint-free action integral whose Euler-Lagrange equations are just the well-known equations of motion for adiabatic compressible flow.
PERFORMANCE OF RC AND FRC WALL PANELS REINFORCED WITH MILD STEEL AND GFRP COMPOSITES IN BLAST EVENTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Timothy Garfield; William D. Richins; Thomas K. Larson
The structural integrity of reinforced concrete structures in blast events is important for critical facilities. This paper presents experimental data generated for calibrating detailed finite element models that predict the performance of reinforced concrete wall panels with a wide range of construction details under blast loading. The test specimens were 1.2 m square wall panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consists of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bar reinforcement (Type A); FRC panels without additional reinforcement (Type B); FRC panels with steel barmore » reinforcement (Type C); NWC panels with glass fiber reinforced polymer (GFRP) bar reinforcement (Type D); and NWC panels reinforced with steel bar reinforcement and external bidirectional GFRP overlays on both faces (Type E). An additional three Type C panels were used as control specimens (CON). Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. The panels were instrumented with strain gauges, and accelerometers; in addition, pressure sensors and high speed videos were employed during the blast events. Panel types C and E had the best performance, whereas panel type B did not perform well. Preliminary dynamic simulations show crack patterns similar to the experimental results.« less
Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.
Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung
2009-08-01
The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.
Accuracy of intravenous infusion pumps in continuous renal replacement therapies.
Jenkins, R; Harrison, H; Chen, B; Arnold, D; Funk, J
1992-01-01
Most extracorporeal continuous renal replacement therapies (CRRT) require inflow pumping of either dialysate, filtrate replacement solution, or both. Outflow of spent dialysate and ultrafiltrate can be accomplished by gravity drainage or pump. Intravenous infusion pumps have been commonly used for these purposes, although little is known about the accuracy of these pumps. To evaluate accuracy of two different types of intravenous infusion pumps used in CRRT, we studied flow rates at nine different pressure variations in three piston type and three linear peristaltic pumps. The results showed that error of either pump was not different for flow rates of 4 and 16 ml/min. Both types of pumps were affected by fluid circuit pressures, although pressure conditions under which error was low were different for each pump type. The linear peristaltic pumps were most accurate under conditions of low pump inlet pressure, whereas piston pumps were most accurate under conditions of low pump pressure gradient (outlet minus inlet) of 0 or -100 mmHg. The magnitude of error outside these conditions was substantial, reaching 12.5% for the linear peristaltic pump when inlet pressure was -100 mmHg and outlet pressure was 100 mmHg. Error may be minimized in the clinical setting by choosing the pump type best suited for the pressure conditions expected for the renal replacement modality in use.
Friction of Compression-ignition Engines
NASA Technical Reports Server (NTRS)
Moore, Charles S; Collins, John H , Jr
1936-01-01
The cost in mean effective pressure of generating air flow in the combustion chambers of single-cylinder compression-ignition engines was determined for the prechamber and the displaced-piston types of combustion chamber. For each type a wide range of air-flow quantities, speeds, and boost pressures was investigated. Supplementary tests were made to determine the effect of lubricating-oil temperature, cooling-water temperature, and compression ratio on the friction mean effective pressure of the single-cylinder test engine. Friction curves are included for two 9-cylinder, radial, compression-ignition aircraft engines. The results indicate that generating the optimum forced air flow increased the motoring losses approximately 5 pounds per square inch mean effective pressure regardless of chamber type or engine speed. With a given type of chamber, the rate of increase in friction mean effective pressure with engine speed is independent of the air-flow speed. The effect of boost pressure on the friction cannot be predicted because the friction was decreased, unchanged, or increased depending on the combustion-chamber type and design details. High compression ratio accounts for approximately 5 pounds per square inch mean effective pressure of the friction of these single-cylinder compression-ignition engines. The single-cylinder test engines used in this investigation had a much higher friction mean effective pressure than conventional aircraft engines or than the 9-cylinder, radial, compression-ignition engines tested so that performance should be compared on an indicated basis.
Black, Joyce; Berke, Christine; Urzendowski, Gail
2012-01-01
The primary objective of this study was to compare facility-acquired pressure ulcer incidence and progression of pressure ulcers present on admission in critically ill patients, using 2 different support surfaces. We completed a comparison cohort study in a surgical intensive care unit (ICU). The study setting was a 12-bed cardiovascular ICU in a university-based hospital in the Midwestern United States. The sample comprised 52 critically ill patients; 31 were placed on low air loss weight-based pressure redistribution-microclimate management system beds and 21 were placed on integrated powered air pressure redistribution beds. Prior to the start of the study, 5 low airloss beds were placed in open rooms in the cardiovascular surgical ICU. Inclusion criteria were anticipated ICU stay of 3 days, and patients did not receive a speciality bed for pulmonary or wound issues. Initial assessment of the patients included risk assessment and prior events that would increase risk for pressure ulcer development such as extended time in operating room, along with skin assessment for existing pressure ulcers. Subjects in both groups had ongoing skin assessment every 3 to 4 days and a subjective evaluation of heel elevation and turning or repositioning by the researcher. Data were collected until the subjects were dismissed from the ICU. Patients admitted to the unit were assigned to open rooms following the usual protocols. The mean length of stay was 7.0 days, with an 8.1-day length of stay for subjects on "low air loss with microclimate management" beds (LAL-MCM) and 6.6 days on the integrated power pressure air redistribution (IP-AR) beds (P = NS). The incidence of pressure ulcers on the buttocks, sacrum, or coccyx was 0% (0/31) on the low air loss bed and 18% (4/21) on the IP-AR bed (P = .046). Five subjects had 6 pressure ulcers on admission. Two pressure ulcers on 2 patients worsened on the integrated power air redistribution beds, which required specialty bed rental costing the facility $4116. No subjects on the low air loss beds experienced worsening of existing pressure ulcer. One patient with a deep tissue injury present on admission improved on the LAL-MCM bed. The IP-AR beds were approximately 7 years old, and the LAL-MCM beds were new. Critically ill subjects placed on low air loss beds with microclimate management in surgical ICUs had a lower pressure ulcer incidence than those placed on integrated powered air pressure redistribution beds. The clinical performance of the IP-AR surfaces may have been influenced by their age.
Vezzalini, Giovanna; Arletti, Rossella; Quartieri, Simona
2014-06-01
This is a comparative study on the high-pressure behavior of microporous materials with an MFI framework type (i.e. natural mutinaite, ZSM-5 and the all-silica phase silicalite-1), based on in-situ experiments in which penetrating and non-penetrating pressure-transmitting media were used. Different pressure-induced phenomena and deformation mechanisms (e.g. pressure-induced over-hydration, pressure-induced amorphization) are discussed. The influence of framework and extra-framework composition and of the presence of silanol defects on the response to the high pressure of MFI-type zeolites is discussed.
NASA Technical Reports Server (NTRS)
Kim, Sang-Wook
1988-01-01
A velocity-pressure integrated, mixed interpolation, Galerkin finite element method for the Navier-Stokes equations is presented. In the method, the velocity variables were interpolated using complete quadratic shape functions and the pressure was interpolated using linear shape functions. For the two dimensional case, the pressure is defined on a triangular element which is contained inside the complete biquadratic element for velocity variables; and for the three dimensional case, the pressure is defined on a tetrahedral element which is again contained inside the complete tri-quadratic element. Thus the pressure is discontinuous across the element boundaries. Example problems considered include: a cavity flow for Reynolds number of 400 through 10,000; a laminar backward facing step flow; and a laminar flow in a square duct of strong curvature. The computational results compared favorable with those of the finite difference methods as well as experimental data available. A finite elememt computer program for incompressible, laminar flows is presented.
Techakanon, Chukwan; Gradziel, Thomas M; Zhang, Lu; Barrett, Diane M
2016-09-28
Fruit maturity is an important factor associated with final product quality, and it may have an effect on the level of browning in peaches that are high pressure processed (HPP). Peaches from three different maturities, as determined by firmness (M1 = 50-55 N, M2 = 35-40 N, and M3 = 15-20 N), were subjected to pressure levels at 0.1, 200, and 400 MPa for 10 min. The damage from HPP treatment results in loss of fruit integrity and the development of browning during storage. Increasing pressure levels of HPP treatment resulted in greater damage, particularly in the more mature peaches, as determined by shifts in transverse relaxation time (T2) of the vacuolar component and by light microscopy. The discoloration of peach slices of different maturities processed at the same pressure was comparable, indicating that the effect of pressure level is greater than that of maturity in the development of browning.
A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time.
Buxi, Dilpreet; Redouté, Jean-Michel; Yuce, Mehmet Rasit
2015-03-01
Blood pressure monitoring based on pulse transit or arrival time has been the focus of much research in order to design ambulatory blood pressure monitors. The accuracy of these monitors is limited by several challenges, such as acquisition and processing of physiological signals as well as changes in vascular tone and the pre-ejection period. In this work, a literature survey covering recent developments is presented in order to identify gaps in the literature. The findings of the literature are classified according to three aspects. These are the calibration of pulse transit/arrival times to blood pressure, acquisition and processing of physiological signals and finally, the design of fully integrated blood pressure measurement systems. Alternative technologies as well as locations for the measurement of the pulse wave signal should be investigated in order to improve the accuracy during calibration. Furthermore, the integration and validation of monitoring systems needs to be improved in current ambulatory blood pressure monitors.
Précigout, Jacques; Stünitz, Holger; Pinquier, Yves; Champallier, Rémi; Schubnel, Alexandre
2018-01-01
In order to address geological processes at great depths, rock deformation should ideally be tested at high pressure (> 0.5 GPa) and high temperature (> 300 °C). However, because of the low stress resolution of current solid-pressure-medium apparatuses, high-resolution measurements are today restricted to low-pressure deformation experiments in the gas-pressure-medium apparatus. A new generation of solid-medium piston-cylinder ("Griggs-type") apparatus is here described. Able to perform high-pressure deformation experiments up to 5 GPa and designed to adapt an internal load cell, such a new apparatus offers the potential to establish a technological basis for high-pressure rheology. This paper provides video-based detailed documentation of the procedure (using the "conventional" solid-salt assembly) to perform high-pressure, high-temperature experiments with the newly designed Griggs-type apparatus. A representative result of a Carrara marble sample deformed at 700 °C, 1.5 GPa and 10-5 s-1 with the new press is also given. The related stress-time curve illustrates all steps of a Griggs-type experiment, from increasing pressure and temperature to sample quenching when deformation is stopped. Together with future developments, the critical steps and limitations of the Griggs apparatus are then discussed. PMID:29683444
Fernando, Malindu E.; Crowther, Robert G.; Lazzarini, Peter A.; Yogakanthi, Saiumaeswar; Sangla, Kunwarjit S.; Buttner, Petra; Jones, Rhondda; Golledge, Jonathan
2017-01-01
Objective High plantar pressures are implicated in the development of diabetes-related foot ulcers. Whether plantar pressures remain high in patients with chronic diabetes-related foot ulcers over time is uncertain. The primary aim of this study was to compare plantar pressures at baseline and three and six months later in participants with chronic diabetes-related foot ulcers (cases) to participants without foot ulcers (controls). Methods Standardised protocols were used to measure mean peak plantar pressure and pressure-time integral at 10 plantar foot sites (the hallux, toes, metatarsals 1 to 5, mid-foot, medial heel and lateral heel) during barefoot walking. Measurements were performed at three study visits: baseline, three and six months. Linear mixed effects random-intercept models were utilised to assess whether plantar pressures differed between cases and controls after adjusting for age, sex, body mass index, neuropathy status and follow-up time. Standardised mean differences (Cohen’s d) were used to measure effect size. Results Twenty-one cases and 69 controls started the study and 16 cases and 63 controls completed the study. Cases had a higher mean peak plantar pressure at several foot sites including the toes (p = 0.005, Cohen’s d = 0.36) and mid-foot (p = 0.01, d = 0.36) and a higher pressure-time integral at the hallux (p<0.001, d = 0.42), metatarsal 1 (p = 0.02, d = 0.33) and mid-foot (p = 0.04, d = 0.64) compared to controls throughout follow-up. A reduction in pressure-time integral at multiple plantar sites over time was detected in all participants (p<0.05, respectively). Conclusions Plantar pressures assessed during gait are higher in diabetes patients with chronic foot ulcers than controls at several plantar sites throughout prolonged follow-up. Long term offloading is needed in diabetes patients with diabetes-related foot ulcers to facilitate ulcer healing. PMID:28859075
A general low frequency acoustic radiation capability for NASTRAN
NASA Technical Reports Server (NTRS)
Everstine, G. C.; Henderson, F. M.; Schroeder, E. A.; Lipman, R. R.
1986-01-01
A new capability called NASHUA is described for calculating the radiated acoustic sound pressure field exterior to a harmonically-excited arbitrary submerged 3-D elastic structure. The surface fluid pressures and velocities are first calculated by coupling a NASTRAN finite element model of the structure with a discretized form of the Helmholtz surface integral equation for the exterior fluid. After the fluid impedance is calculated, most of the required matrix operations are performed using the general matrix manipulation package (DMAP) available in NASTRAN. Far field radiated pressures are then calculated from the surface solution using the Helmholtz exterior integral equation. Other output quantities include the maximum sound pressure levels in each of the three coordinate planes, the rms and average surface pressures and normal velocities, the total radiated power and the radiation efficiency. The overall approach is illustrated and validated using known analytic solutions for submerged spherical shells subjected to both uniform and nonuniform applied loads.
40 CFR 147.3010 - Mechanical integrity tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Mechanical integrity tests. 147.3010..., Ute Mountain Ute, and All Other New Mexico Tribes § 147.3010 Mechanical integrity tests. The... a pressure test, using liquid or gas that clearly demonstrates that mechanical integrity exists at...
Using Weather Types to Understand and Communicate Weather and Climate Impacts
NASA Astrophysics Data System (ADS)
Prein, A. F.; Hale, B.; Holland, G. J.; Bruyere, C. L.; Done, J.; Mearns, L.
2017-12-01
A common challenge in atmospheric research is the translation of scientific advancements and breakthroughs to decision relevant and actionable information. This challenge is central to the mission of NCAR's Capacity Center for Climate and Weather Extremes (C3WE, www.c3we.ucar.edu). C3WE advances our understanding of weather and climate impacts and integrates these advances with distributed information technology to create tools that promote a global culture of resilience to weather and climate extremes. Here we will present an interactive web-based tool that connects historic U.S. losses and fatalities from extreme weather and climate events to 12 large-scale weather types. Weather types are dominant weather situations such as winter high-pressure systems over the U.S. leading to very cold temperatures or summertime moist humid air masses over the central U.S. leading to severe thunderstorms. Each weather type has a specific fingerprint of economic losses and fatalities in a region that is quantified. Therefore, weather types enable a direct connection of observed or forecasted weather situation to loss of life and property. The presented tool allows the user to explore these connections, raise awareness of existing vulnerabilities, and build resilience to weather and climate extremes.
Fan Noise Source Diagnostic Test: Vane Unsteady Pressure Results
NASA Technical Reports Server (NTRS)
Envia, Edmane
2002-01-01
To investigate the nature of fan outlet guide vane pressure fluctuations and their link to rotor-stator interaction noise, time histories of vane fluctuating pressures were digitally acquired as part of the Fan Noise Source Diagnostic Test. Vane unsteady pressures were measured at seven fan tip speeds for both a radial and a swept vane configuration. Using time-domain averaging and spectral analysis, the blade passing frequency (BPF) harmonic and broadband contents of the vane pressures were individually analyzed. Significant Sound Pressure Level (SPL) reductions were observed for the swept vane relative to the radial vane for the BPF harmonics of vane pressure, but vane broadband reductions due to sweep turned out to be much smaller especially on an average basis. Cross-correlation analysis was used to establish the level of spatial coherence of broadband pressures between different locations on the vane and integral length scales of pressure fluctuations were estimated from these correlations. Two main results of this work are: (1) the average broadband level on the vane (in dB) increases linearly with the fan tip speed for both the radial and swept vanes, and (2) the broadband pressure distribution on the vane is nearly homogeneous and its integral length scale is a monotonically decreasing function of fan tip speed.
Hüser, Daniela; Gogol-Döring, Andreas; Chen, Wei
2014-01-01
ABSTRACT Genome-wide analysis of adeno-associated virus (AAV) type 2 integration in HeLa cells has shown that wild-type AAV integrates at numerous genomic sites, including AAVS1 on chromosome 19q13.42. Multiple GAGY/C repeats, resembling consensus AAV Rep-binding sites are preferred, whereas rep-deficient AAV vectors (rAAV) regularly show a random integration profile. This study is the first study to analyze wild-type AAV integration in diploid human fibroblasts. Applying high-throughput third-generation PacBio-based DNA sequencing, integration profiles of wild-type AAV and rAAV are compared side by side. Bioinformatic analysis reveals that both wild-type AAV and rAAV prefer open chromatin regions. Although genomic features of AAV integration largely reproduce previous findings, the pattern of integration hot spots differs from that described in HeLa cells before. DNase-Seq data for human fibroblasts and for HeLa cells reveal variant chromatin accessibility at preferred AAV integration hot spots that correlates with variant hot spot preferences. DNase-Seq patterns of these sites in human tissues, including liver, muscle, heart, brain, skin, and embryonic stem cells further underline variant chromatin accessibility. In summary, AAV integration is dependent on cell-type-specific, variant chromatin accessibility leading to random integration profiles for rAAV, whereas wild-type AAV integration sites cluster near GAGY/C repeats. IMPORTANCE Adeno-associated virus type 2 (AAV) is assumed to establish latency by chromosomal integration of its DNA. This is the first genome-wide analysis of wild-type AAV2 integration in diploid human cells and the first to compare wild-type to recombinant AAV vector integration side by side under identical experimental conditions. Major determinants of wild-type AAV integration represent open chromatin regions with accessible consensus AAV Rep-binding sites. The variant chromatin accessibility of different human tissues or cell types will have impact on vector targeting to be considered during gene therapy. PMID:25031342
NASA Technical Reports Server (NTRS)
Sullivan, J. L.
1975-01-01
The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.
Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee
2017-01-01
In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.
Kim, Hyung Jin; Seo, Yeong Ho
2017-01-01
In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3–5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3–5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more. PMID:29216189
Alemi, Hamid; Khaloo, Pegah; Mansournia, Mohammad Ali; Rabizadeh, Soghra; Salehi, Salome Sadat; Mirmiranpour, Hossein; Meftah, Neda; Esteghamati, Alireza; Nakhjavani, Manouchehr
2018-02-01
Type 2 diabetes is associated with higher pulse pressure. In this study, we assessed and compared effects of classic diabetes treatments on pulse pressure (PP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) in patients with type 2 diabetes.In a retrospective cohort study, 718 non-hypertensive patients with type 2 diabetes were selected and divided into 4 groups including metformin, insulin, glibenclamide+metformin, and metformin+insulin. They were followed for 4 consecutive visits lasting about 45.5 months. Effects of drug regimens on pulse and blood pressure over time were assessed separately and compared in regression models with generalized estimating equation method and were adjusted for age, duration of diabetes, sex, smoking, and body mass index (BMI).Studied groups had no significant change in PP, SBP, and DBP over time. No significant difference in PP and DBP among studied groups was observed (PP:P = 0.090; DBP:P = 0.063). Pairwise comparisons of PP, SBP, and DBP showed no statistically significant contrast between any 2 studied groups. Interactions of time and treatment were not different among groups.Our results demonstrate patients using metformin got higher PP and SBP over time. Averagely, pulse and blood pressure among groups were not different. Trends of variation in pulse and blood pressure were not different among studied diabetes treatments.
Huang, Huan; Yang, Ming; Lu, Cunyue; Xu, Liang; Zhuang, Xiaoqi; Meng, Fan
2013-10-01
Pulsatile left ventricular assist devices (LVADs) driven by electric motors have been widely accepted as a treatment of heart failure. Performance enhancement with computer assistance for this kind of LVAD has seldom been reported. In this article, a numerical method is proposed to assist the design of a cam-type pump. The method requires an integrated model of an LVAD system, consisting of a motor, a transmission mechanism, and a cardiovascular circulation. Performance indices, that is, outlet pressure, outlet flow, and pump efficiency, were used to select the best cam profile from six candidates. A prototype pump connected to a mock circulatory loop (MCL) was used to calibrate the friction coefficient of the cam groove and preliminarily evaluate modeling accuracy. In vitro experiments show that the mean outlet pressure and flow can be predicted with high accuracy by the model, and gross geometries of the measurements can also be reproduced. Simulation results demonstrate that as the total peripheral resistance (TPR) is fixed at 1.1 mm Hg.s/mL, the two-cycle 2/3-rise profile is the best. Compared with other profiles, the maximum increases of pressure and flow indices are 75 and 76%, respectively, and the maximum efficiency increase is over 51%. For different TPRs (0.5∼1.5 mm Hg.s/mL) and operation intervals (0.1∼0.4 s) in counterpulsation, the conclusion is also acceptable. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.
NASA Astrophysics Data System (ADS)
Fekete, Tamás
2018-05-01
Structural integrity calculations play a crucial role in designing large-scale pressure vessels. Used in the electric power generation industry, these kinds of vessels undergo extensive safety analyses and certification procedures before deemed feasible for future long-term operation. The calculations are nowadays directed and supported by international standards and guides based on state-of-the-art results of applied research and technical development. However, their ability to predict a vessel's behavior under accidental circumstances after long-term operation is largely limited by the strong dependence of the analysis methodology on empirical models that are correlated to the behavior of structural materials and their changes during material aging. Recently a new scientific engineering paradigm, structural integrity has been developing that is essentially a synergistic collaboration between a number of scientific and engineering disciplines, modeling, experiments and numerics. Although the application of the structural integrity paradigm highly contributed to improving the accuracy of safety evaluations of large-scale pressure vessels, the predictive power of the analysis methodology has not yet improved significantly. This is due to the fact that already existing structural integrity calculation methodologies are based on the widespread and commonly accepted 'traditional' engineering thermal stress approach, which is essentially based on the weakly coupled model of thermomechanics and fracture mechanics. Recently, a research has been initiated in MTA EK with the aim to review and evaluate current methodologies and models applied in structural integrity calculations, including their scope of validity. The research intends to come to a better understanding of the physical problems that are inherently present in the pool of structural integrity problems of reactor pressure vessels, and to ultimately find a theoretical framework that could serve as a well-grounded theoretical foundation for a new modeling framework of structural integrity. This paper presents the first findings of the research project.
Aeronautic Instruments. Section V : Power Plant Instruments
NASA Technical Reports Server (NTRS)
Washburn, G E; Sylvander, R C; Mueller, E F; Wilhelm, R M; Eaton, H N; Warner, John A C
1923-01-01
Part 1 gives a general discussion of the uses, principles, construction, and operation of airplane tachometers. Detailed description of all available instruments, both foreign and domestic, are given. Part 2 describes methods of tests and effect of various conditions encountered in airplane flight such as change of temperature, vibration, tilting, and reduced air pressure. Part 3 describes the principal types of distance reading thermometers for aircraft engines, including an explanation of the physical principles involved in the functioning of the instruments and proper filling of the bulbs. Performance requirements and testing methods are given and a discussion of the source of error and results of tests. Part 4 gives methods of tests and calibration, also requirements of gauges of this type for the pressure measurement of the air pressure in gasoline tanks and the engine oil pressure on airplanes. Part 5 describes two types of gasoline gauges, the float type and the pressure type. Methods of testing and calibrating gasoline depth gauges are given. The Schroeder, R. A. E., and the Mark II flowmeters are described.
Disturbance torque rejection properties of the NASA/JPL 70-meter antenna axis servos
NASA Technical Reports Server (NTRS)
Hill, R. E.
1989-01-01
Analytic methods for evaluating pointing errors caused by external disturbance torques are developed and applied to determine the effects of representative values of wind and friction torque. The expressions relating pointing errors to disturbance torques are shown to be strongly dependent upon the state estimator parameters, as well as upon the state feedback gain and the flow versus pressure characteristics of the hydraulic system. Under certain conditions, when control is derived from an uncorrected estimate of integral position error, the desired type 2 servo properties are not realized and finite steady-state position errors result. Methods for reducing these errors to negligible proportions through the proper selection of control gain and estimator correction parameters are demonstrated. The steady-state error produced by a disturbance torque is found to be directly proportional to the hydraulic internal leakage. This property can be exploited to provide a convenient method of determining system leakage from field measurements of estimator error, axis rate, and hydraulic differential pressure.
Sensing and Storing the Blood Pressure Measure by Patients through A Platform and Mobile Devices †.
Villarreal, Vladimir; Nielsen, Mel; Samudio, Manuel
2018-06-03
In this article, we present a platform that allows for the integration of different applications for the follow-up of patients with chronic diseases. We developed two elements: a mobile and a web application. The mobile application allows the capture and processing of vital signs for patients with high blood pressure (hypertension). This application allows for the patient to store the data obtained, provides historical information and trends of the stored measures, and provides alerts and recommendations according to ranges of measures that were obtained. The web application allows the doctor and patients to obtain updated information of the disease behavior through the measures obtained. We used different biometric devices including an efimomanometer, glucometer, scale, and a thermometer with a wi-fi connection. Through this web application, we also generated information about average measures at a given time, by age, by region, and by a specific date. The developed system was evaluated in a medical center with different types of patients.
Effect of Isotope Mass in Simulations of JET H-mode Discharges
NASA Astrophysics Data System (ADS)
Snyder, S. E.; Onjun, T.; Kritz, A. H.; Bateman, G.; Parail, V.
2004-11-01
In JET type-I ELMy H-mode discharges, it is found that the height of the pressure pedestal increases and the frequency of the ELMs decreases with increasing isotope mass. These experimentally observed trends are obtained in these simulations only if the pedestal width increases with isotope mass. Simulations are carried out using the JETTO integrated modeling code with a dynamic model for the H-mode pedestal and the ELMs.(T. Onjun et al, Phys. Plasmas 11 (2004) 1469 and 3006.) The HELENA and MISHKA stability codes are applied to calibrate the stability criteria used to trigger ELM crashes in the JETTO code and to explore possible access to second stability in the pedestal. In the simulations, transport in the pedestal is given by the ion thermal neoclassical diffusivity, which increases with isotope mass. Consequently, as the isotope mass is increased, the pressure gradient and the bootstrap current in the pedestal rebuild more slowly after each ELM crash. Several models are explored in which the pedestal width increases with isotope mass.
Autonomous Correction of Sensor Data Applied to Building Technologies Using Filtering Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castello, Charles C; New, Joshua Ryan; Smith, Matt K
2013-01-01
Sensor data validity is extremely important in a number of applications, particularly building technologies where collected data are used to determine performance. An example of this is Oak Ridge National Laboratory s ZEBRAlliance research project, which consists of four single-family homes located in Oak Ridge, TN. The homes are outfitted with a total of 1,218 sensors to determine the performance of a variety of different technologies integrated within each home. Issues arise with such a large amount of sensors, such as missing or corrupt data. This paper aims to eliminate these problems using: (1) Kalman filtering and (2) linear predictionmore » filtering techniques. Five types of data are the focus of this paper: (1) temperature; (2) humidity; (3) energy consumption; (4) pressure; and (5) airflow. Simulations show the Kalman filtering method performed best in predicting temperature, humidity, pressure, and airflow data, while the linear prediction filtering method performed best with energy consumption data.« less
A spectral approach for discrete dislocation dynamics simulations of nanoindentation
NASA Astrophysics Data System (ADS)
Bertin, Nicolas; Glavas, Vedran; Datta, Dibakar; Cai, Wei
2018-07-01
We present a spectral approach to perform nanoindentation simulations using three-dimensional nodal discrete dislocation dynamics. The method relies on a two step approach. First, the contact problem between an indenter of arbitrary shape and an isotropic elastic half-space is solved using a spectral iterative algorithm, and the contact pressure is fully determined on the half-space surface. The contact pressure is then used as a boundary condition of the spectral solver to determine the resulting stress field produced in the simulation volume. In both stages, the mechanical fields are decomposed into Fourier modes and are efficiently computed using fast Fourier transforms. To further improve the computational efficiency, the method is coupled with a subcycling integrator and a special approach is devised to approximate the displacement field associated with surface steps. As a benchmark, the method is used to compute the response of an elastic half-space using different types of indenter. An example of a dislocation dynamics nanoindentation simulation with complex initial microstructure is presented.
Dynamical origin of complex motor patterns
NASA Astrophysics Data System (ADS)
Alonso, L. M.; Alliende, J. A.; Mindlin, G. B.
2010-11-01
Behavior emerges as the nervous system generates motor patterns in charge of driving a peripheral biomechanical device. For several cases in the animal kingdom, it has been identified that the motor patterns used in order to accomplish a diversity of tasks are the different solutions of a simple, low dimensional nonlinear dynamical system. Yet, motor patterns emerge from the interaction of an enormous number of individual dynamical units. In this work, we study the dynamics of the average activity of a large set of coupled excitable units which are periodically forced. We show that low dimensional, yet non trivial dynamics emerges. As a case study, we analyze the air sac pressure patterns used by domestic canaries during song, which consists of a succession of repetitions of different syllable types. We show that the pressure patterns used to generate different syllables can be approximated by the solutions of the investigated model. In this way, we are capable of integrating different description scales of our problem.
NASA Astrophysics Data System (ADS)
Song, Jun Hee; Kim, Hak Kun; Kim, Sam Yeon
2014-07-01
Laminated fiber-reinforced composites can be applied to an insulating structure of a nuclear fusion device. It is necessary to investigate the interlaminar fracture characteristics of the laminated composites for the assurance of design and structural integrity. The three methods used to prepare the glass fiber reinforced plastic composites tested in this study were vacuum pressure impregnation, high pressure laminate (HPL), and prepreg laminate. We discuss the design criteria for safe application of composites and the shear-compressive test methods for evaluating mechanical properties of the material. Shear-compressive tests could be performed successfully using series-type test jigs that were inclined 0°, 30°, 45°, 60°, and 75° to the normal axis. Shear strength depends strongly on the applied compressive stress. The design range of allowable shear stress was extended by use of the appropriate composite fabrication method. HPL had the largest design range, and the allowable interlaminar shear stress was 0.254 times the compressive stress.
Worse cardiac remodeling in response to pressure overload in type 2 diabetes mellitus.
Gonçalves, N; Gomes-Ferreira, C; Moura, C; Roncon-Albuquerque, R; Leite-Moreira, A F; Falcão-Pires, I
2016-08-15
Diabetic cardiomyopathy is characterized by cardiac structural and functional abnormalities. Additionally, chronic pressure overload conditions are highly prevalent amongst diabetic population and this association leads to a more severe myocardial impairment. The differences in myocardial pathophysiology between type 1 and type 2 diabetes mellitus (DM) still remain to be clarified. Thus, we aimed to investigate biventricular structural and functional changes promoted by the two types of DM and the impact of concomitant chronic pressure overload. Wistar rats were injected with streptozotocin (Type 1 DM, T1DM) or fed with a hypercaloric diet (Type 2 DM, T2DM). Pressure overload was imposed in DM animals by aortic constriction and after 5weeks of DM the cardiac function and structure were evaluated. Both types of DM promoted hypertrophy, increased fibrosis and advanced glycation end-products deposition, in the two ventricles. Interestingly, the induced myocardial alterations were distinct. While T1DM stimulated a pronounced hypertrophy and extracellular matrix remodeling, T2DM induced functional impairment. The negative impact of the association of DM with aortic constriction was more pronounced in T2DM, promoting impaired function and increased stiffness, particularly in the right ventricle. Our study demonstrated that the two types of diabetes induce distinct cardiac alterations per se or when combined with chronic pressure overload. T1DM promoted a more extensive remodeling in cardiac structure while T2DM significantly impaired ventricular function. The impact of pressure overload was more notorious in T2DM as observed by worse myocardial remodeling, suggesting a higher susceptibility to the deleterious effects of chronic pressure overload, namely hypertension, among this diabetic population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Initial Operation of the Miniaturized Inductively Heated Plasma Generator IPG6
NASA Astrophysics Data System (ADS)
Dropmann, Michael; Herdrich, Georg; Laufer, Rene; Koch, Helmut; Gomringer, Chris; Cook, Mike; Schmoke, Jimmy; Matthews, Lorin; Hyde, Truell
2012-10-01
In close collaboration between the Center for Astrophysics, Space Physics and Engineering Research (CASPER) at Baylor University, Texas, and the Institute of Space Systems (IRS) at the University of Stuttgart, Germany, two plasma wind tunnel facilities of similar type have been established using the inductively heated plasma source IPG6 which is based on proven IRS designs. The facility at Baylor University (IPG6-B) works at a frequency of 13.56 MHz and a maximum power of 15 kW. A vacuum pump of 160m^3/h in combination with a butterfly valve allows pressure control in a wide range. First experiments have been conducted with Air, O2 and N2 as working gases and volumetric flow rates of up to 14 L/min at pressures of a few 100 Pa, although pressures below 1 Pa are achievable at lower flow rates. The maximum tested electric power so far was 8 kW. Plasma powers and total pressures in the plasma jet have been obtained. In the near future the set up of additional diagnostics, the use of other gases (i.e. H2, He), and the integration of a dust particle accelerator are planned. The intended fields of research are basic investigation in thermo-chemistry and plasma radiation, space plasma environments and high heat fluxes e.g. in fusion devices or during atmospheric entry of spacecraft.
NASA Technical Reports Server (NTRS)
Russin, W. R.
1974-01-01
Tests were conducted to determine the performance of a hydrogen burner used to produce a test gas that simulates air entering a scramjet combustor at various flight conditions. The test gas simulates air in that it duplicates the total temperature, total pressure, and the volume fraction of oxygen of air at flight conditions. The main objective of the tests was to determine the performance of the burner as a function of the effective exhaust port area. The conclusions were: (1) pressure oscillations of the chugging type were reduced in amplitude to plus or minus 2 percent of the mean pressure level by proper sizing of hydrogen, oxygen, and air injector flow areas; (2) combustion efficiency remained essentially constant as the exhaust port area was increased by a factor of 3.4; (3) the mean total temperature determined from integrating the exit radial gas property profiles was within plus or minus 5 percent of the theoretical bulk total temperature; (4) the measured exit total temperature profile had a local peak temperature more than 30 percent greater than the theoretical bulk total temperature; and (5) measured heat transfer to the burner liner was 75 percent of that predicted by theory based on a flat radial temperature profile.
Structural Concepts Study of Non-circular Fuselage Configurations
NASA Technical Reports Server (NTRS)
Mukhopadhyay, Vivel
1996-01-01
A preliminary study of structural concepts for noncircular fuselage configurations is presented. For an unconventional flying-wing type aircraft, in which the fuselage is inside the wing, multiple fuselage bays with non-circular sections need to be considered. In a conventional circular fuselage section, internal pressure is carried efficiently by a thin skin via hoop tension. If the section is non-circular, internal pressure loads also induce large bending stresses. The structure must also withstand additional bending and compression loads from aerodynamic and gravitational forces. Flat and vaulted shell structural configurations for such an unconventional, non-circular pressurized fuselage of a large flying-wing were studied. A deep honeycomb sandwich-shell and a ribbed double-wall shell construction were considered. Combinations of these structural concepts were analyzed using both analytical and simple finite element models of isolated sections for a comparative conceptual study. Weight, stress, and deflection results were compared to identify a suitable configuration for detailed analyses. The flat sandwich-shell concept was found preferable to the vaulted shell concept due to its superior buckling stiffness. Vaulted double-skin ribbed shell configurations were found to be superior due to their weight savings, load diffusion, and fail-safe features. The vaulted double-skin ribbed shell structure concept was also analyzed for an integrated wing-fuselage finite element model. Additional problem areas such as wing-fuselage junction and pressure-bearing spar were identified.
Khatri, Kshitij; Klein, Joshua A; White, Mitchell R; Grant, Oliver C; Leymarie, Nancy; Woods, Robert J; Hartshorn, Kevan L; Zaia, Joseph
2016-06-01
Despite sustained biomedical research effort, influenza A virus remains an imminent threat to the world population and a major healthcare burden. The challenge in developing vaccines against influenza is the ability of the virus to mutate rapidly in response to selective immune pressure. Hemagglutinin is the predominant surface glycoprotein and the primary determinant of antigenicity, virulence and zoonotic potential. Mutations leading to changes in the number of HA glycosylation sites are often reported. Such genetic sequencing studies predict at best the disruption or creation of sequons for N-linked glycosylation; they do not reflect actual phenotypic changes in HA structure. Therefore, combined analysis of glycan micro and macro-heterogeneity and bioassays will better define the relationships among glycosylation, viral bioactivity and evolution. We present a study that integrates proteomics, glycomics and glycoproteomics of HA before and after adaptation to innate immune system pressure. We combined this information with glycan array and immune lectin binding data to correlate the phenotypic changes with biological activity. Underprocessed glycoforms predominated at the glycosylation sites found to be involved in viral evolution in response to selection pressures and interactions with innate immune-lectins. To understand the structural basis for site-specific glycan microheterogeneity at these sites, we performed structural modeling and molecular dynamics simulations. We observed that the presence of immature, high-mannose type glycans at a particular site correlated with reduced accessibility to glycan remodeling enzymes. Further, the high mannose glycans at sites implicated in immune lectin recognition were predicted to be capable of forming trimeric interactions with the immune-lectin surfactant protein-D. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Active Flow Control on a Boundary-Layer-Ingesting Inlet
NASA Technical Reports Server (NTRS)
Gorton, Susan Althoff; Owens, Lewis R.; Jenkins, Luther N.; Allan, Brian G.; Schuster, Ernest P.
2004-01-01
Boundary layer ingestion (BLI) is explored as means to improve overall system performance for Blended Wing Body configuration. The benefits of BLI for vehicle system performance benefit are assessed with a process derived from first principles suitable for highly-integrated propulsion systems. This performance evaluation process provides framework within which to assess the benefits of an integrated BLI inlet and lays the groundwork for higher-fidelity systems studies. The results of the system study show that BLI provides a significant improvement in vehicle performance if the inlet distortion can be controlled, thus encouraging the pursuit of active flow control (AFC) as a BLI enabling technology. The effectiveness of active flow control in reducing engine inlet distortion was assessed using a 6% scale model of a 30% BLI offset, diffusing inlet. The experiment was conducted in the NASA Langley Basic Aerodynamics Research Tunnel with a model inlet designed specifically for this type of testing. High mass flow pulsing actuators provided the active flow control. Measurements were made of the onset boundary layer, the duct surface static pressures, and the mass flow through the duct and the actuators. The distortion was determined by 120 total pressure measurements located at the aerodynamic interface plane. The test matrix was limited to a maximum freestream Mach number of 0.15 with scaled mass flows through the inlet for that condition. The data show that the pulsed actuation can reduce distortion from 29% to 4.6% as measured by the circumferential distortion descriptor DC60 using less than 1% of inlet mass flow. Closed loop control of the actuation was also demonstrated using a sidewall surface static pressure as the response sensor.
Visible Wavelength Exoplanet Phase Curves from Global Albedo Maps
NASA Astrophysics Data System (ADS)
Webber, Matthew; Cahoy, Kerri Lynn
2015-01-01
To investigate the effect of three-dimensional global albedo maps we use an albedo model that: calculates albedo spectra for each points across grid in longitude and latitude on the planetary disk, uses the appropriate angles for the source-observer geometry for each location, and then weights and sums these spectra using the Tschebychev-Gauss integration method. This structure permits detailed 3D modeling of an illuminated planetary disk and computes disk-integrated phase curves. Different pressure-temperature profiles are used for each location based on geometry and dynamics. We directly couple high-density pressure maps from global dynamic radiative-transfer models to compute global cloud maps. Cloud formation is determined from the correlation of the species condensation curves with the temperature-pressure profiles. We use the detailed cloud patterns, of spatial-varying composition and temperature, to determine the observable albedo spectra and phase curves for exoplanets Kepler-7b and HD189733b. These albedo spectra are used to compute planet-star flux ratios using PHOENIX stellar models, exoplanet orbital parameters, and telescope transmission functions. Insight from the Earthshine spectrum and solid surface albedo functions (e.g. water, ice, snow, rocks) are used with our planetary grid to determine the phase curve and flux ratios of non-uniform Earth and Super Earth-like exoplanets with various rotation rates and stellar types. Predictions can be tailored to the visible and Near-InfraRed (NIR) spectral windows for the Kepler space telescope, Hubble space telescope, and future observatories (e.g. WFIRST, JWST, Exo-C, Exo-S). Additionally, we constrain the effect of exoplanet urban-light on the shape of the night-side phase curve for Earths and Super-Earths.
Macura, Katarzyna Jadwiga; Thompson, Richard Eugene; Bluemke, David Alan; Genadry, Rene
2015-11-28
To define the magnetic resonance imaging (MRI) parameters differentiating urethral hypermobility (UH) and intrinsic sphincter deficiency (ISD) in women with stress urinary incontinence (SUI). The static and dynamic MR images of 21 patients with SUI were correlated to urodynamic (UD) findings and compared to those of 10 continent controls. For the assessment of the urethra and integrity of the urethral support structures, we applied the high-resolution endocavitary MRI, such as intraurethral MRI, endovaginal or endorectal MRI. For the functional imaging of the urethral support, we performed dynamic MRI with the pelvic phased array coil. We assessed the following MRI parameters in both the patient and the volunteer groups: (1) urethral angle; (2) bladder neck descent; (3) status of the periurethral ligaments, (4) vaginal shape; (5) urethral sphincter integrity, length and muscle thickness at mid urethra; (6) bladder neck funneling; (7) status of the puborectalis muscle; (8) pubo-vaginal distance. UDs parameters were assessed in the patient study group as follows: (1) urethral mobility angle on Q-tip test; (2) Valsalva leak point pressure (VLPP) measured at 250 cc bladder volume; and (3) maximum urethral closure pressure (MUCP). The UH type of SUI was defined with the Q-tip test angle over 30 degrees, and VLPP pressure over 60 cm H2O. The ISD incontinence was defined with MUCP pressure below 20 cm H2O, and VLPP pressure less or equal to 60 cm H2O. We considered the associations between the MRI and clinical data and UDs using a variety of statistical tools to include linear regression, multivariate logistic regression and receiver operating characteristic (ROC) analysis. All statistical analyses were performed using STATA version 9.0 (StataCorp LP, College Station, TX). In the incontinent group, 52% have history of vaginal delivery trauma as compared to none in control group (P < 0.001). There was no difference between the continent volunteers and incontinent patients in body habitus as assessed by the body mass index. Pubovaginal distance and periurethral ligament disruption are significantly associated with incontinence; periurethral ligament symmetricity reduces the odds of incontinence by 87%. Bladder neck funneling and length of the suprapubic urethral sphincter are significantly associated with the type of incontinence on UDs; funneling reduced the odds of pure UH by almost 95%; increasing suprapubic urethral sphincter length at rest is highly associated with UH. Both MRI variables result in a predictive model for UDs diagnosis (area under the ROC = 0.944). MRI may play an important role in assessing the contribution of hypermobility and sphincteric dysfunction to the SUI in women when considering treatment options.
Macura, Katarzyna Jadwiga; Thompson, Richard Eugene; Bluemke, David Alan; Genadry, Rene
2015-01-01
AIM: To define the magnetic resonance imaging (MRI) parameters differentiating urethral hypermobility (UH) and intrinsic sphincter deficiency (ISD) in women with stress urinary incontinence (SUI). METHODS: The static and dynamic MR images of 21 patients with SUI were correlated to urodynamic (UD) findings and compared to those of 10 continent controls. For the assessment of the urethra and integrity of the urethral support structures, we applied the high-resolution endocavitary MRI, such as intraurethral MRI, endovaginal or endorectal MRI. For the functional imaging of the urethral support, we performed dynamic MRI with the pelvic phased array coil. We assessed the following MRI parameters in both the patient and the volunteer groups: (1) urethral angle; (2) bladder neck descent; (3) status of the periurethral ligaments, (4) vaginal shape; (5) urethral sphincter integrity, length and muscle thickness at mid urethra; (6) bladder neck funneling; (7) status of the puborectalis muscle; (8) pubo-vaginal distance. UDs parameters were assessed in the patient study group as follows: (1) urethral mobility angle on Q-tip test; (2) Valsalva leak point pressure (VLPP) measured at 250 cc bladder volume; and (3) maximum urethral closure pressure (MUCP). The UH type of SUI was defined with the Q-tip test angle over 30 degrees, and VLPP pressure over 60 cm H2O. The ISD incontinence was defined with MUCP pressure below 20 cm H2O, and VLPP pressure less or equal to 60 cm H2O. We considered the associations between the MRI and clinical data and UDs using a variety of statistical tools to include linear regression, multivariate logistic regression and receiver operating characteristic (ROC) analysis. All statistical analyses were performed using STATA version 9.0 (StataCorp LP, College Station, TX). RESULTS: In the incontinent group, 52% have history of vaginal delivery trauma as compared to none in control group (P < 0.001). There was no difference between the continent volunteers and incontinent patients in body habitus as assessed by the body mass index. Pubovaginal distance and periurethral ligament disruption are significantly associated with incontinence; periurethral ligament symmetricity reduces the odds of incontinence by 87%. Bladder neck funneling and length of the suprapubic urethral sphincter are significantly associated with the type of incontinence on UDs; funneling reduced the odds of pure UH by almost 95%; increasing suprapubic urethral sphincter length at rest is highly associated with UH. Both MRI variables result in a predictive model for UDs diagnosis (area under the ROC = 0.944). CONCLUSION: MRI may play an important role in assessing the contribution of hypermobility and sphincteric dysfunction to the SUI in women when considering treatment options. PMID:26644825
Van Ouytsel, Joris; Walrave, Michel; Ponnet, Koen; Heirman, Wannes
2015-02-01
When a sexting message spreads to an unintended audience, it can adversely affect the victim's reputation. Sexting incidents constitute a potential school safety risk. Just as with other types of adolescent risk behavior, school nurses might have to initiate the first response when a sexting episode arises, but a school nurse's role goes beyond intervention. They can also play an important role in the prevention of sexting and its related risks. This article reviews the links between adolescent sexting, other types of risk behavior, and its emotional and psychosocial conditions. Seven databases were examined and nine studies remained for further review. The review of the literature shows that adolescent sexting is cross sectionally associated with a range of health-risk behaviors. Youth who engage in sexting are also found to experience peer pressure and a range of emotional difficulties. The results can guide school nurse education and practice. © The Author(s) 2014.
High temperature ceramic-tubed reformer
NASA Astrophysics Data System (ADS)
Williams, Joseph J.; Rosenberg, Robert A.; McDonough, Lane J.
1990-03-01
The overall objective of the HiPHES project is to develop an advanced high-pressure heat exchanger for a convective steam/methane reformer. The HiPHES steam/methane reformer is a convective, shell and tube type, catalytic reactor. The use of ceramic tubes will allow reaction temperature higher than the current state-of-the-art outlet temperatures of about 1600 F using metal tubes. Higher reaction temperatures increase feedstock conversion to synthesis gas and reduce energy requirements compared to currently available radiant-box type reformers using metal tubes. Reforming of natural gas is the principal method used to produce synthesis gas (primarily hydrogen and carbon monoxide, H2 and CO) which is used to produce hydrogen (for refinery upgrading), methanol, as well as several other important materials. The HiPHES reformer development is an extension of Stone and Webster's efforts to develop a metal-tubed convective reformer integrated with a gas turbine cycle.
ERIC Educational Resources Information Center
Kraemer Diaz, Anne E.; Spears Johnson, Chaya R.; Arcury, Thomas A.
2015-01-01
Scientific integrity is necessary for strong science; yet many variables can influence scientific integrity. In traditional research, some common threats are the pressure to publish, competition for funds, and career advancement. Community-based participatory research (CBPR) provides a different context for scientific integrity with additional and…
High Reynolds number analysis of an axisymmetric afterbody with flow separation
NASA Technical Reports Server (NTRS)
Carlson, John R.; Reubush, David E.
1996-01-01
The ability of a three-dimensional Navier-Stokes method, PAB3D, to predict nozzle afterbody flow at high Reynolds number was assessed. Predicted surface pressure coefficient distributions and integrated afterbody drag are compared with experimental data obtained from the NASA-Langley 0.3 m Transonic Cryogenic Tunnel. Predicted afterbody surface pressures matched experimental data fairly closely. The change in the pressure coefficient distribution with Reynolds number was slightly over-predicted. Integrated afterbody drag was typically high compared to the experimental data. The change in afterbody pressure drag with Reynolds number was fairly small. The predicted point of flow separation on the nozzle was slightly downstream of that observed from oilflow data at low Reynolds numbers and had a very slight Reynolds number dependence, moving slightly further downstream as Reynolds number increased.
Research on pressure sensors for biomedical instruments
NASA Technical Reports Server (NTRS)
Angell, J. B.
1975-01-01
The development of a piezo-resistive pressure transducer is discussed suitable for recording pressures typically encountered in biomedical applications. The pressure transducer consists of a thin silicon diaphragm containing four strain-sensitive resistors, and is fabricated using silicon monolithic integrated-circuit technology. The pressure transducers can be as small as 0.7 mm outer diameter, and are, as a result, suitable for mounting at the tip of a catheter. Pressure-induced stress in the diaphragm is sensed by the resistors, which are interconnected to form a Wheatstone bridge.
Tests Of Array Of Flush Pressure Sensors
NASA Technical Reports Server (NTRS)
Larson, Larry J.; Moes, Timothy R.; Siemers, Paul M., III
1992-01-01
Report describes tests of array of pressure sensors connected to small orifices flush with surface of 1/7-scale model of F-14 airplane in wind tunnel. Part of effort to determine whether pressure parameters consisting of various sums, differences, and ratios of measured pressures used to compute accurately free-stream values of stagnation pressure, static pressure, angle of attack, angle of sideslip, and mach number. Such arrays of sensors and associated processing circuitry integrated into advanced aircraft as parts of flight-monitoring and -controlling systems.
Fukui, Michiaki; Ushigome, Emi; Tanaka, Muhei; Hamaguchi, Masahide; Tanaka, Toru; Atsuta, Haruhiko; Ohnishi, Masayoshi; Oda, Yohei; Hasegawa, Goji; Nakamura, Naoto
2013-03-01
Recent studies have suggested that not only mean blood pressure but also variability in blood pressure might be related to cardiovascular disease. The aim of this study was to investigate the association between home blood pressure variability on one occasion and markers of arterial stiffness in patients with type 2 diabetes. We investigated the relationship between the s.d. of clinic- or home-measured systolic blood pressure on one occasion and pulse wave velocity (PWV) in 332 patients with type 2 diabetes, and we evaluated whether the SD of clinic- or home-measured systolic blood pressure on one occasion was an independent determinant of PWV by multivariate linear regression analysis, after adjustment for known risk factors for arterial stiffness, including sex, age, duration of diabetes, body mass index, hemoglobin A1c, serum total cholesterol, triglycerides, smoking status, drinking alcohol, presence of antihypertensive medication, average systolic blood pressure and heart rate. Age, average morning home-measured systolic blood pressure, heart rate and PWV (r=0.259, P<0.0001) were positively correlated with the s.d. of morning home blood pressure on one occasion. Multiple regression analysis demonstrated that age, average morning home-measured systolic blood pressure (P=0.0019), heart rate and the s.d. of morning home-measured systolic blood pressure on one occasion (P=0.0159) were independently associated with PWV. In conclusion, home blood pressure variability on one occasion was correlated with PWV, independent of other known risk factors, in Japanese patients with type 2 diabetes.
A 2 TiO 5 (A = Dy, Gd, Er, Yb) at High Pressure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Sulgiye; Rittman, Dylan R.; Tracy, Cameron L.
The structural evolution of lanthanide A2TiO5 (A = Dy, Gd, Yb, and Er) at high pressure is investigated using synchrotron X-ray diffraction. The effects of A-site cation size and of the initial structure are systematically examined by varying the composition of the isostructural lanthanide titanates, and the structure of dysprosium titanate polymorphs (orthorhombic, hexagonal and cubic), respectively. All samples undergo irreversible high pressure phase transformations, but with different onset pressures depending on the initial structure. While individual phase exhibits different phase transformation histories, all samples commonly experience a sluggish transformation to a defect cotunnite-like (Pnma) phase for a certain pressuremore » range. Orthorhombic Dy2TiO5 and Gd2TiO5 form P21am at pressures below 9 GPa and Pnma above 13 GPa. Pyrochlore-type Dy2TiO5 and Er2TiO5 as well as defect-fluorite-type Yb2TiO5 form Pnma at ~ 21 GPa, followed by Im-3m. Hexagonal Dy2TiO5 forms Pnma directly, although a small amount of remnants of hexagonal Dy2TiO5 is observed even at the highest pressure (~ 55 GPa) reached, indicating a kinetic limitations in the hexagonal Dy2TiO5 phase transformations at high pressure. Decompression of these materials leads to different metastable phases. Most interestingly, a high pressure cubic X-type phase (Im-3m) is confirmed using highresolution transmission electron microscopy on recovered pyrochlore-type Er2TiO5. The kinetic constraints on this metastable phase yield a mixture of both the X-type phase and amorphous domains upon pressure release. This is the first observation of an X-type phase for an A2BO5 composition at high pressure.« less
A Wireless Pressure Sensor Integrated with a Biodegradable Polymer Stent for Biomedical Applications
Park, Jongsung; Kim, Ji-Kwan; Patil, Swati J.; Park, Jun-Kyu; Park, SuA; Lee, Dong-Weon
2016-01-01
This paper describes the fabrication and characterization of a wireless pressure sensor for smart stent applications. The micromachined pressure sensor has an area of 3.13 × 3.16 mm2 and is fabricated with a photosensitive SU-8 polymer. The wireless pressure sensor comprises a resonant circuit and can be used without the use of an internal power source. The capacitance variations caused by changes in the intravascular pressure shift the resonance frequency of the sensor. This change can be detected using an external antenna, thus enabling the measurement of the pressure changes inside a tube with a simple external circuit. The wireless pressure sensor is capable of measuring pressure from 0 mmHg to 230 mmHg, with a sensitivity of 0.043 MHz/mmHg. The biocompatibility of the pressure sensor was evaluated using cardiac cells isolated from neonatal rat ventricular myocytes. After inserting a metal stent integrated with the pressure sensor into a cardiovascular vessel of an animal, medical systems such as X-ray were employed to consistently monitor the condition of the blood vessel. No abnormality was found in the animal blood vessel for approximately one month. Furthermore, a biodegradable polymer (polycaprolactone) stent was fabricated with a 3D printer. The polymer stent exhibits better sensitivity degradation of the pressure sensor compared to the metal stent. PMID:27271619
Park, Jongsung; Kim, Ji-Kwan; Patil, Swati J; Park, Jun-Kyu; Park, SuA; Lee, Dong-Weon
2016-06-02
This paper describes the fabrication and characterization of a wireless pressure sensor for smart stent applications. The micromachined pressure sensor has an area of 3.13 × 3.16 mm² and is fabricated with a photosensitive SU-8 polymer. The wireless pressure sensor comprises a resonant circuit and can be used without the use of an internal power source. The capacitance variations caused by changes in the intravascular pressure shift the resonance frequency of the sensor. This change can be detected using an external antenna, thus enabling the measurement of the pressure changes inside a tube with a simple external circuit. The wireless pressure sensor is capable of measuring pressure from 0 mmHg to 230 mmHg, with a sensitivity of 0.043 MHz/mmHg. The biocompatibility of the pressure sensor was evaluated using cardiac cells isolated from neonatal rat ventricular myocytes. After inserting a metal stent integrated with the pressure sensor into a cardiovascular vessel of an animal, medical systems such as X-ray were employed to consistently monitor the condition of the blood vessel. No abnormality was found in the animal blood vessel for approximately one month. Furthermore, a biodegradable polymer (polycaprolactone) stent was fabricated with a 3D printer. The polymer stent exhibits better sensitivity degradation of the pressure sensor compared to the metal stent.
Penny, Jeannette Østergaard; Speedtsberg, Merete Brink; Kallemose, Thomas; Bencke, Jesper
2018-03-16
The study sought to investigate whether an orthotic stiletto could modulate the pressure and comfort under the forefoot, arch and heel that stiletto wearers experience. Twenty-two women participated. We measured the peak pressure and pressure-time integral for orthotic stilettos with built-in metatarsal pad, heel cup and arch support; standard stilettos without inlays; and trainers. Comfort was recorded during 3 × 3 working days. The orthotic stiletto exhibited lower metatarsal head1 (MTH) and MTH2+3 and heel pressures than the standard stiletto (p < .01), and a long second metatarsal increased MTH2+3 pressure (p < .01). The comfort in the forefoot and heel was higher in the orthotic stiletto than in the standard one (p < .01), and comfort in the forefoot was correlated to the pressure-time integral of MTH2+3 (p = .03) and not peak pressure. Off-the-rack orthotic stilettos can notably reduce plantar pressures and improve forefoot and heel comfort during everyday use. Practitioner Summary: Off-the-rack orthotic stilettos with built-in metatarsal pad, arch support and heel caps can lower the pressure under the heel and forefoot in comparison with a standard stiletto and can improve comfort during everyday use. Having a long second metatarsal is a risk factor for increased forefoot pressure.
A Balanced Diaphragm Type of Maximum Cylinder Pressure Indicator
NASA Technical Reports Server (NTRS)
Spanogle, J A; Collins, John H , Jr
1930-01-01
A balanced diaphragm type of maximum cylinder pressure indicator was designed to give results consistent with engine operating conditions. The apparatus consists of a pressure element, a source of controlled high pressure and a neon lamp circuit. The pressure element, which is very compact, permits location of the diaphragm within 1/8 inch of the combustion chamber walls without water cooling. The neon lamp circuit used for indicating contact between the diaphragm and support facilitates the use of the apparatus with multicylinder engines.
Three types of cavitation caused by air seeding.
Shen, Fanyi; Wang, Yuansheng; Cheng, Yanxia; Zhang, Li
2012-11-01
There are different opinions of the dynamics of an air bubble entering a xylem conduit. In this paper, we present a thorough mechanical analysis and conclude that there are three types of cavitation caused by air seeding. After an air seed enters a conduit at high xylem pressure P'(1), along with the drop of the water potential, it will expand gradually to a long-shaped bubble and extend continually. This is the first type of air seeding, or the type of expanding gradually. When the xylem pressure is moderate, right after an air seed enters a conduit, it will expand first. Then, as soon as the pressure reaches a threshold the bubble will blow up to form a bubble in long shape, accompanied by acoustic (or ultra-acoustic) emission. It will extend further as xylem pressure decreases continually. This is the second type of air seeding, or the type of expanding-exploding, becoming a long-shaped bubble-lengthening by degrees. In the range of P'(1) ≤ - 3P(o) (P(o) is atmospheric pressure), soon after an air seed is sucked into a conduit it will explode immediately and the conduit will be full of the gas of the bubble instantly. This is the third type of air seeding, or the type of sudden exploding and filling conduit instantly. The third type is the frequent event in daily life of plant.
Stability of fluorite-type La 2Ce 2O 7 under extreme conditions
Zhang, F. X.; Tracy, C. L.; Lang, M.; ...
2016-03-03
Here, the structural stability of fluorite-type La 2Ce 2O 7 was studied at pressure up to ~40 GPa and under hydrothermal conditions (~1 GPa, 350 °C), respectively, using synchrotron x-ray diffraction (XRD) and Raman scattering measurements. XRD measurements indicated that fluorite-type La 2Ce 2O 7 is not stable at pressures greater than 22.6 GPa and slowly transforms to a high-pressure phase. The high-pressure phase is not stable and changes back to the fluorite-type structure when pressure is released. The La 2Ce 2O 7 fluorite is also not stable under hydrothermal conditions and begins to react with water at 200~250 °C.more » Both Raman and XRD results suggest that lanthanum hydroxide La(OH) 3 and La 3+-doped CeO 2 fluorite are the dominant products after hydrothermal treatment.« less
Kwon, Hae-Yeon
2017-01-01
[Purpose] The purpose of this study was to determine differences in respiratory function and pressure among three groups of children with cerebral palsy as a predominant abnormal movement which included spastic type, dyskinetic type, and ataxic type. [Subjects and Methods] Forty-three children with cerebral palsy of 5–13 years of age in I–III levels according to the Gross Motor Function Classification System, the study subjects were divided by stratified random sampling into three groups of spastic type, dyskinetic type, and ataxic type. For reliability of the measurement results, respiratory function and pressure of the children with cerebral palsy were measured by the same inspector using Spirometer Pony FX (Cosmed Ltd., Italy) equipment, and the subject’s guardians (legal representative) was always made to observe. [Results] In the respiratory function, there were significant differences among three groups in all of forced vital capacity, forced expiratory volume at one second, and peak expiratory flow. For respiratory pressure, the maximal inspiratory pressure had significant differences among three groups, although the maximal expiratory pressure had no significant difference. [Conclusion] Therefore, pediatric physical therapists could be provided with important clinical information in understanding the differences in respiratory function and pressure for the children with cerebral palsy showing predominantly abnormal movement as a diverse qualitative characteristics of the muscle tone and movement patterns, and in planning intervention programs for improvement of respiratory capacity. PMID:28265153
Determination of vertical pressures on running wheels of freight trolleys of bridge type cranes
NASA Astrophysics Data System (ADS)
Goncharov, K. A.; Denisov, I. A.
2018-03-01
The problematic issues of the design of the bridge-type trolley crane, connected with ensuring uniform load distribution between the running wheels, are considered. The shortcomings of the existing methods of calculation of reference pressures are described. The results of the analytical calculation of the pressure of the support wheels are compared with the results of the numerical solution of this problem for various schemes of trolley supporting frames. Conclusions are given on the applicability of various methods for calculating vertical pressures, depending on the type of metal structures used in the trolley.
Pretreatment of high solid microbial sludges
Rivard, C.J.; Nagle, N.J.
1998-07-28
A process and apparatus are disclosed for pretreating microbial sludges in order to enhance secondary anaerobic digestion. The pretreatment process involves disrupting the cellular integrity of municipal sewage sludge through a combination of thermal, explosive decompression and shear forces. The sludge is pressurized and pumped to a pretreatment reactor where it is mixed with steam to heat and soften the sludge. The pressure of the sludge is suddenly reduced and explosive decompression forces are imparted which partially disrupt the cellular integrity of the sludge. Shear forces are then applied to the sludge to further disrupt the cellular integrity of the sludge. Disrupting cellular integrity releases both soluble and insoluble organic constituents and thereby renders municipal sewage sludge more amenable to secondary anaerobic digestion. 1 fig.
NASA Technical Reports Server (NTRS)
Borderies, Nicole; Longaretti, Pierre-Yves
1990-01-01
The purpose of this paper is to present a model for the radiation pressure acceleration of a spherical satellite, due to the radiation reflected by a planet with a uniform albedo. A particular choice of variables allows one to reduce the surface integrals over the lit portion of the planet visible to the satellite to one-dimensional integrals. Exact analytical expressions are found for the integrals corresponding to the case where the spacecraft does not 'see' the terminator. The other integrals can be computer either numerically, or analytical in an approximate form. The results are compared with those of Lochry (1966). The model is applied to Magellan, a spacecraft orbiting Venus.
Coupled NASTRAN/boundary element formulation for acoustic scattering
NASA Technical Reports Server (NTRS)
Everstine, Gordon C.; Henderson, Francis M.; Schuetz, Luise S.
1987-01-01
A coupled finite element/boundary element capability is described for calculating the sound pressure field scattered by an arbitrary submerged 3-D elastic structure. Structural and fluid impedances are calculated with no approximation other than discretization. The surface fluid pressures and normal velocities are first calculated by coupling a NASTRAN finite element model of the structure with a discretized form of the Helmholtz surface integral equation for the exterior field. Far field pressures are then evaluated from the surface solution using the Helmholtz exterior integral equation. The overall approach is illustrated and validated using a known analytic solution for scattering from submerged spherical shells.
Human in the Loop Integrated Life Support Systems Ground Testing
NASA Technical Reports Server (NTRS)
Henninger, Donald L.; Marmolejo, Jose A.; Seaman, Calvin H.
2012-01-01
Human exploration missions beyond low earth orbit will be long duration with abort scenarios of days to months. This necessitates provisioning the crew with all the things they will need to sustain themselves while carrying out mission objectives. Systems engineering and integration is critical to the point where extensive integrated testing of life support systems on the ground is required to identify and mitigate risks. Ground test facilities (human-rated altitude chambers) at the Johnson Space Center are being readied to integrate all the systems for a mission along with a human test crew. The relevant environment will include deep space habitat human accommodations, sealed atmosphere capable of 14.7 to 8 psi total pressure and 21 to 32% oxygen concentration, life support systems (food, air, and water), communications, crew accommodations, medical, EVA, tools, etc. Testing periods will approximate those of the expected missions (such as a near Earth asteroid, Earth-Moon L2 or L1, the moon, Mars). This type of integrated testing is needed for research and technology development as well as later during the mission design, development, test, and evaluation (DDT&E) phases of an approved program. Testing will evolve to be carried out at the mission level fly the mission on the ground . Mission testing will also serve to inform the public and provide the opportunity for active participation by international, industrial and academic partners.
Provol, Steve J.; Russell, David B.; Isaksson, Matti J.
1994-01-01
A power plant having a system for converting coal to power in a gas turbine comprises a coal fed pressurized circulating bed for converting coal to pressurized gases, a gas turbine having a compressor for pressurizing air for the pressurized circulating bed and expander for receiving and expanding hot combustion gases for powering a generator, a first fast acting valve for controlling the pressurized air, a second fast acting valve means for controlling pressurized gas from the compressor to the expander.
30 CFR 57.4430 - Surface storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... liquids shall be— (1) Capable of withstanding working pressures and stresses and compatible with the type.... These pressure relief requirements do not apply to tanks used for storage of Class IIIB liquids that are... withstanding working pressures and stresses; (2) Compatible with the type of liquid stored; and (3) Maintained...
30 CFR 57.4430 - Surface storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... liquids shall be— (1) Capable of withstanding working pressures and stresses and compatible with the type.... These pressure relief requirements do not apply to tanks used for storage of Class IIIB liquids that are... withstanding working pressures and stresses; (2) Compatible with the type of liquid stored; and (3) Maintained...
46 CFR 154.438 - Design vapor pressure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Design vapor pressure. 154.438 Section 154.438 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Independent Tank Type A § 154.438 Design vapor pressure. (a) If the surface of an independent tank type A are...
46 CFR 154.445 - Design vapor pressure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Design vapor pressure. 154.445 Section 154.445 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Independent Tank Type B § 154.445 Design vapor pressure. If the surfaces of an independent tank type B are...
Experimental Evidence of Volcanic Earthquakes Induced by Different Fluid Types
NASA Astrophysics Data System (ADS)
Clarke, J. A.; Adam, L.; Sarout, J.; van Wijk, K.; Dautriat, J. D.; Kennedy, B.
2017-12-01
Low Frequency volcanic seismicity has long been associated with resonance in fluid-filled cracks or conduits driven by pressure perturbations at depth. In volcano monitoring, fluid movement, fracturing and the conduit geometry are interpreted based on field observations, laboratory experiments, and numerical models. Fluids in a volcanic environment include gasses, brine and magmas with different viscosities. Magma viscosity is a key influence on eruptive behaviour. For example, increasing magma viscosity is known to favour explosive eruptions. How different fluids affect volcano seismicity is not well understood. Here, we explore the effects of fluid type on volcano seismic signals. Frequency content in the signal, frequency of the events, source mechanism and quality factor are studied. We simulate volcano tectonic (fracturing) and volcano seismic (fluid movement) signatures in a controlled laboratory environment using a range of rock samples, fluid types and pressure conditions. The viscosity of the fluids spans six orders of magnitude, representing realistic volcanic fluids. Microseismicity is generated by venting pressurised fluids through pre-generated fracture networks in cylindrical rock core samples and detected by an array of 18 ultrasonic transducers. We fracture samples of two lithologies: 1) low porosity impermeable granite samples and 2) a permeable volcanic ash tuff sample. Permeability and porosity in the granites are due to a fracture network, while in the tuff a high porosity matrix ( 40 %) and a fracture network interact. The fluids used are nitrogen gas, water, and mixtures of water and glycerol. We generate and detect a myriad of seismic event types, some of which resemble well-known families of volcano-tectonic, low-frequency, hybrid and tremor-type seismicity. Samples with fluids of lower density and viscosity generate a higher number of seismic events. We will present an integrated analysis of the event types, frequency content, source locations and mechanisms. In addition, we explore the importance of seismic wave attenuation by studying the relationship between wave path and event frequency content.
Application of Newton's method to the postbuckling of rings under pressure loadings
NASA Technical Reports Server (NTRS)
Thurston, Gaylen A.
1989-01-01
The postbuckling response of circular rings (or long cylinders) is examined. The rings are subjected to four types of external pressure loadings; each type of pressure is defined by its magnitude and direction at points on the buckled ring. Newton's method is applied to the nonlinear differential equations of the exact inextensional theory for the ring problem. A zeroth approximation for the solution of the nonlinear equations, based on the mode shape corresponding to the first buckling pressure, is derived in closed form for each of the four types of pressure. The zeroth approximation is used to start the iteration cycle in Newton's method to compute numerical solutions of the nonlinear equations. The zeroth approximations for the postbuckling pressure-deflection curves are compared with the converged solutions from Newton's method and with similar results reported in the literature.
Integrated Heat Switch/Oxide Sorption Compressor
NASA Technical Reports Server (NTRS)
Bard, Steven
1989-01-01
Thermally-driven, nonmechanical compressor uses container filled with compressed praseodymium cerium oxide powder (PrCeOx) to provide high-pressure flow of oxygen gas for driving closed-cycle Joule-Thomson-expansion refrigeration unit. Integrated heat switch/oxide sorption compressor has no moving parts except check valves, which control flow of oxygen gas between compressor and closed-cycle Joule-Thomson refrigeration system. Oxygen expelled from sorbent at high pressure by evacuating heat-switch gap and turning on heater.
Peng, Wei; Qi, Bing; Wang, Anbo
2006-05-16
A flow rate fiber optic transducer is made self-compensating for both temperature and pressure by using preferably well-matched integral Fabry-Perot sensors symmetrically located around a cantilever-like structure. Common mode rejection signal processing of the outputs allows substantially all effects of both temperature and pressure to be compensated. Additionally, the integral sensors can individually be made insensitive to temperature.
NASA Astrophysics Data System (ADS)
de la Cruz, Javier; Cano, Ulises; Romero, Tatiana
2016-10-01
A critical parameter for PEM fuel cell's electric contact is the nominal clamping pressure. Predicting the mechanical behavior of all components in a fuel cell stack is a very complex task due to the diversity of materials properties. Prior to the integration of a 3 kW PEMFC power plant, a numerical simulation was performed in order to obtain the mechanical stress distribution for two of the most pressure sensitive components of the stack: the membrane, and the graphite plates. The stress distribution of the above mentioned components was numerically simulated by finite element analysis and the stress magnitude for the membrane was confirmed using pressure films. Stress values were found within the elastic zone which guarantees mechanical integrity of fuel cell components. These low stress levels particularly for the membrane will allow prolonging the life and integrity of the fuel cell stack according to its design specifications.
Mobile health platform for pressure ulcer monitoring with electronic health record integration.
Rodrigues, Joel J P C; Pedro, Luís M C C; Vardasca, Tomé; de la Torre-Díez, Isabel; Martins, Henrique M G
2013-12-01
Pressure ulcers frequently occur in patients with limited mobility, for example, people with advanced age and patients wearing casts or prostheses. Mobile information communication technologies can help implement ulcer care protocols and the monitoring of patients with high risk, thus preventing or improving these conditions. This article presents a mobile pressure ulcer monitoring platform (mULCER), which helps control a patient's ulcer status during all stages of treatment. Beside its stand-alone version, it can be integrated with electronic health record systems as mULCER synchronizes ulcer data with any electronic health record system using HL7 standards. It serves as a tool to integrate nursing care among hospital departments and institutions. mULCER was experimented with in different mobile devices such as LG Optimus One P500, Samsung Galaxy Tab, HTC Magic, Samsung Galaxy S, and Samsung Galaxy i5700, taking into account the user's experience of different screen sizes and processing characteristics.
Hasan, Y; Go, J; Hashmi, S M; Valestin, J; Schey, R
2015-04-01
The standard protocol for esophageal manometry involves placing the patient in the supine position with head turned to left (supine head left [SHL]) while evaluating liquid bolus swallows. Routinely, semisolid or solid boluses are not evaluated. Currently, the daily American diet includes up to 40% solid or semisolid texture. Thus far, the data on the effect of different bolus on high-resolution esophageal pressure topography (HREPT) parameters are scarce. This study aims to evaluate the effect of every day bolus consistencies in different body positions on HREPT variables. HREPT was performed on healthy volunteers with a modified protocol including liquid swallows in the SHL position followed by applesauce (semisolid), cracker (solid), and marshmallow (soft solid) in three different positions (SHL, sitting, and standing). A total of 38 healthy adult subjects (22 males and 16 females, median age = 27, and mean body mass index = 25) were evaluated. The resting upper esophageal sphincter pressure was significantly different while subjects swallowed crackers, applesauce, and marshmallows in most positions compared with liquid SHL (P < 0.05). The lower esophageal sphincter, contractile front velocity, and distal contractile integral pressures did not differ in all different consistencies compared with SHL. The integrated relaxation period was significantly higher with solid bolus compared with liquid bolus only in SHL position. The intrabolus pressure was significantly different with solid and soft solid boluses in all postures compared to liquid SHL. The American diet consistency affects upper esophageal sphincter pressure and partially integrated relaxation period and intrabolus pressure in various positions. Semisolid bolus swallows do not cause substantial pressure changes and are safe for evaluation and maintaining adequate caloric intake in patients with dysphagia who cannot tolerate solids. © 2014 International Society for Diseases of the Esophagus.
Application of ideal pressure distribution in development process of automobile seats.
Kilincsoy, U; Wagner, A; Vink, P; Bubb, H
2016-07-19
In designing a car seat the ideal pressure distribution is important as it is the largest contact surface between the human and the car. Because of obstacles hindering a more general application of the ideal pressure distribution in seating design, multidimensional measuring techniques are necessary with extensive user tests. The objective of this study is to apply and integrate the knowledge about the ideal pressure distribution in the seat design process for a car manufacturer in an efficient way. Ideal pressure distribution was combined with pressure measurement, in this case pressure mats. In order to integrate this theoretical knowledge of seating comfort in the seat development process for a car manufacturer a special user interface was defined and developed. The mapping of the measured pressure distribution in real-time and accurately scaled to actual seats during test setups directly lead to design implications for seat design even during the test situation. Detailed analysis of the subject's feedback was correlated with objective measurements of the subject's pressure distribution in real time. Therefore existing seating characteristics were taken into account as well. A user interface can incorporate theoretical and validated 'state of the art' models of comfort. Consequently, this information can reduce extensive testing and lead to more detailed results in a shorter time period.
Pressure-induced enhancement in the thermoelectric properties of monolayer and bilayer SnSe2
NASA Astrophysics Data System (ADS)
Zou, Daifeng; Yu, Chuanbin; Li, Yuhao; Ou, Yun; Gao, Yongyi
2018-03-01
The electronic structures of monolayer and bilayer SnSe2 under pressure were investigated by using first-principles calculations including van der Waals interactions. For monolayer SnSe2, the variation of electronic structure under pressure is controlled by pressure-dependent lattice parameters. For bilayer SnSe2, the changes in electronic structure under pressure are dominated by intralayer and interlayer atomic interactions. The n-type thermoelectric properties of monolayer and bilayer SnSe2 under pressure were calculated on the basis of the semi-classical Boltzmann transport theory. It was found that the electrical conductivity of monolayer and bilayer SnSe2 can be enhanced under pressure, and such dependence can be attributed to the pressure-induced changes of the Se-Sn antibonding states in conduction band. Finally, the doping dependence of power factors of n-type monolayer and bilayer SnSe2 at three different pressures were estimated, and the results unveiled that thermoelectric performance of n-type monolayer and bilayer SnSe2 can be improved by applying external pressure. This study benefits to understand the nature of the transport properties for monolayer and bilayer SnSe2 under pressure, and it offers valuable insight for designing high-performance thermoelectric few-layered SnSe2 through strain engineering induced by external pressure.
Pressure-induced enhancement in the thermoelectric properties of monolayer and bilayer SnSe2.
Zou, Daifeng; Yu, Chuanbin; Li, Yuhao; Ou, Yun; Gao, Yongyi
2018-03-01
The electronic structures of monolayer and bilayer SnSe 2 under pressure were investigated by using first-principles calculations including van der Waals interactions. For monolayer SnSe 2 , the variation of electronic structure under pressure is controlled by pressure-dependent lattice parameters. For bilayer SnSe 2 , the changes in electronic structure under pressure are dominated by intralayer and interlayer atomic interactions. The n -type thermoelectric properties of monolayer and bilayer SnSe 2 under pressure were calculated on the basis of the semi-classical Boltzmann transport theory. It was found that the electrical conductivity of monolayer and bilayer SnSe 2 can be enhanced under pressure, and such dependence can be attributed to the pressure-induced changes of the Se-Sn antibonding states in conduction band. Finally, the doping dependence of power factors of n -type monolayer and bilayer SnSe 2 at three different pressures were estimated, and the results unveiled that thermoelectric performance of n -type monolayer and bilayer SnSe 2 can be improved by applying external pressure. This study benefits to understand the nature of the transport properties for monolayer and bilayer SnSe 2 under pressure, and it offers valuable insight for designing high-performance thermoelectric few-layered SnSe 2 through strain engineering induced by external pressure.
Wind tunnel test IA300 analysis and results, volume 1
NASA Technical Reports Server (NTRS)
Kelley, P. B.; Beaufait, W. B.; Kitchens, L. L.; Pace, J. P.
1987-01-01
The analysis and interpretation of wind tunnel pressure data from the Space Shuttle wind tunnel test IA300 are presented. The primary objective of the test was to determine the effects of the Space Shuttle Main Engine (SSME) and the Solid Rocket Booster (SRB) plumes on the integrated vehicle forebody pressure distributions, the elevon hinge moments, and wing loads. The results of this test will be combined with flight test results to form a new data base to be employed in the IVBC-3 airloads analysis. A secondary objective was to obtain solid plume data for correlation with the results of gaseous plume tests. Data from the power level portion was used in conjunction with flight base pressures to evaluate nominal power levels to be used during the investigation of changes in model attitude, eleveon deflection, and nozzle gimbal angle. The plume induced aerodynamic loads were developed for the Space Shuttle bases and forebody areas. A computer code was developed to integrate the pressure data. Using simplified geometrical models of the Space Shuttle elements and components, the pressure data were integrated to develop plume induced force and moments coefficients that can be combined with a power-off data base to develop a power-on data base.
Evaluation of SSME test data reduction methods
NASA Technical Reports Server (NTRS)
Santi, L. Michael
1994-01-01
Accurate prediction of hardware and flow characteristics within the Space Shuttle Main Engine (SSME) during transient and main-stage operation requires a significant integration of ground test data, flight experience, and computational models. The process of integrating SSME test measurements with physical model predictions is commonly referred to as data reduction. Uncertainties within both test measurements and simplified models of the SSME flow environment compound the data integration problem. The first objective of this effort was to establish an acceptability criterion for data reduction solutions. The second objective of this effort was to investigate the data reduction potential of the ROCETS (Rocket Engine Transient Simulation) simulation platform. A simplified ROCETS model of the SSME was obtained from the MSFC Performance Analysis Branch . This model was examined and tested for physical consistency. Two modules were constructed and added to the ROCETS library to independently check the mass and energy balances of selected engine subsystems including the low pressure fuel turbopump, the high pressure fuel turbopump, the low pressure oxidizer turbopump, the high pressure oxidizer turbopump, the fuel preburner, the oxidizer preburner, the main combustion chamber coolant circuit, and the nozzle coolant circuit. A sensitivity study was then conducted to determine the individual influences of forty-two hardware characteristics on fourteen high pressure region prediction variables as returned by the SSME ROCETS model.
Eizayaga, Francisco; Scorticati, Camila; Prestifilippo, Juan P; Romay, Salvador; Fernandez, Maria A; Castro, José L; Lemberg, Abraham; Perazzo, Juan C
2006-01-01
AIM: To study the blood-brain barrier integrity in prehepatic portal hypertensive rats induced by partial portal vein ligation, at 14 and 40 d after ligation when portal pressure is spontaneously normalized. METHODS: Adult male Wistar rats were divided into four groups: Group I: Sham14d , sham operated; Group II: PH14d , portal vein stenosis; (both groups were used 14 days after surgery); Group III: Sham40d, Sham operated and Group IV: PH40d Portal vein stenosis (Groups II and IV used 40 d after surgery). Plasma ammonia, plasma and cerebrospinal fluid protein and liver enzymes concentrations were determined. Trypan and Evans blue dyes, systemically injected, were investigated in hippocampus to study blood-brain barrier integrity. Portal pressure was periodically recorded. RESULTS: Forty days after stricture, portal pressure was normalized, plasma ammonia was moderately high, and both dyes were absent in central nervous system parenchyma. All other parameters were reestablished. When portal pressure was normalized and ammonia level was lowered, but not normal, the altered integrity of blood-brain barrier becomes reestablished. CONCLUSION: The impairment of blood-brain barrier and subsequent normalization could be a mechanism involved in hepatic encephalopathy reversibility. Hemodynamic changes and ammonia could trigger blood-brain barrier alterations and its reestablishment. PMID:16552803
40 CFR 147.3107 - Mechanical integrity.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Mechanical integrity. 147.3107 Section 147.3107 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS... Oklahoma Indian Tribes § 147.3107 Mechanical integrity. (a) Monitoring of annulus pressure conducted...
Pressure distribution along the AGS vacuum chambers with new types of pump out conduits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nayak, S.; Mapes, M.; Smart, L.
2015-10-28
The AGS HEBT and ring vacuum system is monitored by the discharge current of the magnet ion pumps, which is proportional to the pressure at the inlet port of these ion pumps. The discharge current is measured and suitably calibrated to indicate the ion pump pressure. In order to calculate the vacuum chamber pressure from the ion pump pressure, a detailed analysis is essential to compute their difference in different scenarios. Such analysis has been carried out numerically in the past for the system with the older type of pump out conduits, and similar analysis using FEM in ANSYS ismore » presented in this paper with the newer type of pump out conduit.« less
Mizuno, Ju; Namba, Chikara; Takahashi, Toru
2014-10-01
We investigated external pressure on peroneal nerve tract coming in contact with two kinds of leg holders using pressure distribution measurement system BIG- MAT® (Nitta Corp., Osaka) in the lithotomy position Peak contact (active) pressure at the left fibular head region coming in contact with knee-crutch-type leg holder M® (Takara Belmont Corp., Osaka), which supports the left popliteal fossa, was 78.0 ± 26.4 mmHg. On the other hand, peak contact pressure at the left lateral lower leg region coming in contact with boot-support-type leg holder Bel Flex® (Takara Belmont Corp., Osaka), which supports the left lower leg and foot was 26.3±7.9 mmHg. These results suggest that use of knee-crutch-type leg holder is more likely to induce common peroneal nerve palsy at the fibular head region, but use of boot-support-type leg holder dose not easily induce superficial peroneal nerve palsy at the lateral lower leg region, because capillary blood pressure is known to be 32 mmHg. Safer holders for positioning will be developed to prevent nerve palsy based on the analysis of chronological change in external pressure using BIG-MAT® system during anesthesia.
Associations Between Economic Pressure and Diabetes Efficacy in Couples With Type 2 Diabetes
Novak, Joshua R.; Anderson, Jared R.; Johnson, Matthew D.; Walker, Ann; Wilcox, Allison; Lewis, Virginia L.; Robbins, David C.
2017-01-01
Objective The purpose of this study was to explore dyadic associations between economic pressure and diabetes self-efficacy via emotional distress in patients with type 2 diabetes and their partners. Background Understanding how economic pressure is associated with successful diabetes management is an important area for research, as couples with type 2 diabetes can incur heavy economic pressures that could likely influence diabetes outcomes. Method Data from 117 married couples were used to test actor–partner associations using moderated mediation analyses in a structural equation modeling framework. Problem-solving communication was tested as a possible moderator of the economic pressure–emotional distress pathway. Results Results revealed that greater patient economic pressure was associated with lower patient and spouse confidence in the patient’s diabetes management ability through higher levels of patient emotional distress. The deleterious association between economic pressure and emotional distress was less pronounced when spouses reported more effective problem-solving communication. Conclusion These results provide evidence that the economic pressure couples with type 2 diabetes face may reduce the patient and spouse’s confidence in the patient’s diabetes management ability. Implications This study demonstrates the importance of couple’s relationship processes in buffering the impact of economic pressure on diabetes management, providing a clear target for intervention and education efforts. PMID:29151662
Wu, Haiyan; van Thiel, Bibi S; Bautista-Niño, Paula K; Reiling, Erwin; Durik, Matej; Leijten, Frank P J; Ridwan, Yanto; Brandt, Renata M C; van Steeg, Harry; Dollé, Martijn E T; Vermeij, Wilbert P; Hoeijmakers, Jan H J; Essers, Jeroen; van der Pluijm, Ingrid; Danser, A H Jan; Roks, Anton J M
2017-08-01
DNA damage is an important contributor to endothelial dysfunction and age-related vascular disease. Recently, we demonstrated in a DNA repair-deficient, prematurely aging mouse model ( Ercc1 Δ/- mice) that dietary restriction (DR) strongly increases life- and health span, including ameliorating endothelial dysfunction, by preserving genomic integrity. In this mouse mutant displaying prominent accelerated, age-dependent endothelial dysfunction we investigated the signaling pathways involved in improved endothelium-mediated vasodilation by DR, and explore the potential role of the renin-angiotensin system (RAS). Ercc1 Δ/- mice showed increased blood pressure and decreased aortic relaxations to acetylcholine (ACh) in organ bath experiments. Nitric oxide (NO) signaling and phospho-Ser 1177 -eNOS were compromised in Ercc1 Δ / - DR improved relaxations by increasing prostaglandin-mediated responses. Increase of cyclo-oxygenase 2 and decrease of phosphodiesterase 4B were identified as potential mechanisms. DR also prevented loss of NO signaling in vascular smooth muscle cells and normalized angiotensin II (Ang II) vasoconstrictions, which were increased in Ercc1 Δ/- mice. Ercc1 Δ/ - mutants showed a loss of Ang II type 2 receptor-mediated counter-regulation of Ang II type 1 receptor-induced vasoconstrictions. Chronic losartan treatment effectively decreased blood pressure, but did not improve endothelium-dependent relaxations. This result might relate to the aging-associated loss of treatment efficacy of RAS blockade with respect to endothelial function improvement. In summary, DR effectively prevents endothelium-dependent vasodilator dysfunction by augmenting prostaglandin-mediated responses, whereas chronic Ang II type 1 receptor blockade is ineffective. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.
Fluctuating surface pressure measurements on USB wing using two types of transducers
NASA Technical Reports Server (NTRS)
Reed, J. B.
1975-01-01
Measurements of the fluctuating pressures on the wing surface of an upper-surface-blown powered-lift model and a JT15 engine were obtained using two types of pressure transducers. The pressures were measured using overall-fluctuating pressures and power spectral density analyses for various thrust settings and two jet impingement angles. Comparison of the data from the two transducers indicate that similar results are obtained in the lower frequency ranges for both transducers. The data also indicate that for this configuration, the highest pressure levels occur at frequencies below 2000 Hz.
NASA Technical Reports Server (NTRS)
Schuster, David M.; Panda, Jayanta; Ross, James C.; Roozeboom, Nettie H.; Burnside, Nathan J.; Ngo, Christina L.; Kumagai, Hiro; Sellers, Marvin; Powell, Jessica M.; Sekula, Martin K.;
2016-01-01
This NESC assessment examined the accuracy of estimating buffet loads on in-line launch vehicles without booster attachments using sparse unsteady pressure measurements. The buffet loads computed using sparse sensor data were compared with estimates derived using measurements with much higher spatial resolution. The current method for estimating launch vehicle buffet loads is through wind tunnel testing of models with approximately 400 unsteady pressure transducers. Even with this relatively large number of sensors, the coverage can be insufficient to provide reliable integrated unsteady loads on vehicles. In general, sparse sensor spacing requires the use of coherence-length-based corrections in the azimuthal and axial directions to integrate the unsteady pressures and obtain reasonable estimates of the buffet loads. Coherence corrections have been used to estimate buffet loads for a variety of launch vehicles with the assumption methodology results in reasonably conservative loads. For the Space Launch System (SLS), the first estimates of buffet loads exceeded the limits of the vehicle structure, so additional tests with higher sensor density were conducted to better define the buffet loads and possibly avoid expensive modifications to the vehicle design. Without the additional tests and improvements to the coherence-length analysis methods, there would have been significant impacts to the vehicle weight, cost, and schedule. If the load estimates turn out to be too low, there is significant risk of structural failure of the vehicle. This assessment used a combination of unsteady pressure-sensitive paint (uPSP), unsteady pressure transducers, and a dynamic force and moment balance to investigate the integration schemes used with limited unsteady pressure data by comparing them with direct integration of extremely dense fluctuating pressure measurements. An outfall of the assessment was to evaluate the potential of using the emerging uPSP technique in a production test environment for future launch vehicles. The results show that modifications to the current technique can improve the accuracy of buffet estimates. More importantly, the uPSP worked remarkably well and, with improvements to the frequency response, sensitivity, and productivity, will provide an enhanced method for measuring wind tunnel buffet forcing functions (BFFs).
Determination of pressure drop across activated carbon fiber respirator cartridges.
Balanay, Jo Anne G; Lungu, Claudiu T
2016-01-01
Activated carbon fiber (ACF) is considered as an alternative adsorbent to granular activated carbon (GAC) for the development of thinner, lighter, and efficient respirators because of their larger surface area and adsorption capacities, thinner critical bed depth, lighter weight, and fabric form. This study aims to measure the pressure drop across different types of commercially available ACFs in respirator cartridges to determine the ACF composition and density that will result in acceptably breathable respirators. Seven ACF types in cloth (ACFC) and felt (ACFF) forms were tested. ACFs in cartridges were challenged with pre-conditioned constant air flow (43 LPM, 23°C, 50% RH) at different compositions (single- or combination-ACF type) in a test chamber. Pressure drop across ACF cartridges were obtained using a micromanometer, and compared among different cartridge configurations, to those of the GAC cartridge, and to the NIOSH breathing resistance requirements for respirator cartridges. Single-ACF type cartridges filled with any ACFF had pressure drop measurements (23.71-39.93 mmH2O) within the NIOSH inhalation resistance requirement of 40 mmH2O, while those of the ACFC cartridges (85.47±3.67 mmH2O) exceeded twice the limit due possibly to the denser weaving of ACFC fibers. All single ACFF-type cartridges had higher pressure drop compared to the GAC cartridge (23.13±1.14 mmH2O). Certain ACF combinations (2 ACFF or ACFC/ACFF types) resulted to pressure drop (26.39-32.81 mmH2O) below the NIOSH limit. All single-ACFF type and all combination-ACF type cartridges with acceptable pressure drop had much lower adsorbent weights than GAC (≤15.2% of GAC weight), showing potential for light-weight respirator cartridges. 100% ACFC in cartridges may result to respirators with high breathing resistance and, thus, is not recommended. The more dense ACFF and ACFC types may still be possibly used in respirators by combining them with less dense ACFF materials and/or by reducing cartridge bed depth to reduce pressure drop to acceptable levels. ACFF by itself may be more appropriate as adsorbent materials in ACF respirator cartridges in terms of acceptable breathing resistance.
The Influence of Hydraulic Fracturing on Carbon Storage Performance
NASA Astrophysics Data System (ADS)
Fu, Pengcheng; Settgast, Randolph R.; Hao, Yue; Morris, Joseph P.; Ryerson, Frederick J.
2017-12-01
Conventional principles of the design and operation of geologic carbon storage (GCS) require injecting CO2 below the caprock fracturing pressure to ensure the integrity of the storage complex. In nonideal storage reservoirs with relatively low permeability, pressure buildup can lead to hydraulic fracturing of the reservoir and caprock. While the GCS community has generally viewed hydraulic fractures as a key risk to storage integrity, a carefully designed stimulation treatment under appropriate geologic conditions could provide improved injectivity while maintaining overall seal integrity. A vertically contained hydraulic fracture, either in the reservoir rock or extending a limited height into the caprock, provides an effective means to access reservoir volume far from the injection well. Employing a fully coupled numerical model of hydraulic fracturing, solid deformation, and matrix fluid flow, we study the enabling conditions, processes, and mechanisms of hydraulic fracturing during CO2 injection. A hydraulic fracture's pressure-limiting behavior dictates that the near-well fluid pressure is only slightly higher than the fracturing pressure of the rock and is insensitive to injection rate and mechanical properties of the formation. Although a fracture contained solely within the reservoir rock with no caprock penetration, would be an ideal scenario, poroelastic principles dictate that sustaining such a fracture could lead to continuously increasing pressure until the caprock fractures. We also investigate the propagation pattern and injection pressure responses of a hydraulic fracture propagating in a caprock subjected to heterogeneous in situ stress. The results have important implications for the use of hydraulic fracturing as a tool for managing storage performance.
Structural Integrity of Water Reactor Pressure Boundary Components.
1980-08-01
Boiler and Pressure Vessel Code , Sec. Ill). Estimates of the upper shelf K level from small-specimen...from Appendix A of Section XI of the ASME Boiler and Pressure Vessel Code [11. Figure 9 shows this same data set, together with earlier data for...0969, NRL Memo- randum Report 4063, Sep. 1979. 11. Section XI - ASME Boiler and Pressure Vessel Code , Rules for Inservice Inspection of Nuclear
Intapad, Suttira; Ojeda, Norma B.; Varney, Elliott; Royals, Thomas P.; Alexander, Barbara T.
2015-01-01
The renal endothelin system contributes to sex differences in blood pressure with males demonstrating greater endothelin type-A receptor-mediated responses relative to females. Intrauterine growth restriction programs hypertension and enhanced renal sensitivity to acute angiotensin II in male growth-restricted rats. Endothelin is reported to work synergistically with angiotensin II. Thus, this study tested the hypothesis that endothelin augments the blood pressure response to acute angiotensin II in male growth-restricted rats. Systemic and renal hemodynamics were determined in response to acute angiotensin II (100 nanogram/kilogram/minute for 30 minutes) with and without the endothelin type-A receptor antagonist, ABT 627(10 nanogram/kilogram/minute for 30 minutes), in rats pretreated with enalapril (250 milligram/Liter for one week) to normalize the endogenous renin angiotensin system. Endothelin type-A receptor blockade reduced angiotensin II-mediated increases in blood pressure in male control and male growth-restricted rats. Endothelin type-A receptor blockade also abolished hyper-responsiveness to acute angiotensin II in male growth-restricted rats. Yet, blood pressure remained significantly elevated above baseline following endothelin type-A receptor blockade suggesting that factors in addition to endothelin contribute to the basic angiotensin II-induced pressor response in male rats. We also determined sex-specific effects of endothelin on acute angiotensin II-mediated hemodynamic responses. Endothelin type-A receptor blockade did not reduce acute angiotensin II-mediated increases in blood pressure in female control or growth-restricted rats, intact or ovariectomized. Thus, these data suggest that endothelin type-A receptor blockade contributes to hypersensitivity to acute angiotensin II in male growth-restricted rats and further supports the sex-specific effect of endothelin on blood pressure. PMID:26459423
NASA Astrophysics Data System (ADS)
Sahatiya, Parikshit; Badhulika, Sushmee
2017-03-01
This paper reports a new type of electronic, recoverable skin-like pressure and strain sensor, produced on a flexible, biodegradable pencil-eraser substrate and fabricated using a solvent-free, low-cost and energy efficient process. Multi-walled carbon nanotube (MWCNT) film, the strain sensing element, was patterned on pencil eraser with a rolling pin and a pre-compaction mechanical press. This induces high interfacial bonding between the MWCNTs and the eraser substrate, which enables the sensor to achieve recoverability under ambient conditions. The eraser serves as a substrate for strain sensing, as well as acting as a dielectric for capacitive pressure sensing, thereby eliminating the dielectric deposition step, which is crucial in capacitive-based pressure sensors. The strain sensing transduction mechanism is attributed to the tunneling effect, caused by the elastic behavior of the MWCNTs and the strong mechanical interlock between MWCNTs and the eraser substrate, which restricts slippage of MWCNTs on the eraser thereby minimizing hysteresis. The gauge factor of the strain sensor was calculated to be 2.4, which is comparable to and even better than most of the strain and pressure sensors fabricated with more complex designs and architectures. The sensitivity of the capacitive pressure sensor was found to be 0.135 MPa-1.To demonstrate the applicability of the sensor as artificial electronic skin, the sensor was assembled on various parts of the human body and corresponding movements and touch sensation were monitored. The entire fabrication process is scalable and can be integrated into large areas to map spatial pressure distributions. This low-cost, easily scalable MWCNT pin-rolled eraser-based pressure and strain sensor has huge potential in applications such as artificial e-skin in flexible electronics and medical diagnostics, in particular in surgery as it provides high spatial resolution without a complex nanostructure architecture.
Experimental study of dynamic effective stress coefficient for ultrasonic velocities of Bakken cores
NASA Astrophysics Data System (ADS)
Ma, X.; Zoback, M. D.
2016-12-01
We have performed a series of exhaustive experiments to measure the effective stress coefficient (α) of the tight cores from the Bakken shale oil play. Five distinct, bedding-normal cores from a vertical well were tested, covering the sequences of Lodgepole, Middle Bakken, and Three Forks. The scope of this laboratory study is two-fold: (1) to obtain the dynamic effective stress coefficient for ultrasonic velocities; (2) to characterize the poromechanical properties in relation to rock's mineral composition and microstructure. The experiments were carried out as follows: Argon-saturated specimen (1-inch length, 1-inch diameter) was subjected to hydrostatic confining pressure under drained conditions. Pore pressure was regulated as Argon was injected into both ends of the specimen. We drilled multiple non-through-going boreholes (1-mm diameter) in the specimen to facilitate pore pressure equilibrium, without compromising its integrity. The specimen was put through a loading path to experience confining pressure and pore pressure up to 70 and 60 MPa, respectively. P- and S- wave velocities were measured and used to calculate the rock's dynamic effective stress coefficient. Results of all five cores unanimously show that the dynamic a is a function of both confining and pore pressures, regardless of the wave type and loading path. When the simple effective stress is low, α is close to unity; however, α consistently increases as the simple effective stress rises and can reach as much as 3 when the latter reaches 60 MPa. This trend is rather surprising as it is diametrically the opposite of what was observed for the static α. A possible explanation is that high-frequency wave-induced pore pressure increment may have not remained equilibrated throughout the pore space, especially in very thin cracks, according to the squirt model. This phenomenon can be enhanced when the bulk modulus of pore fluid (gas typically considered to be `soft' and `non-viscous') increases with pore pressure and becomes comparable to the crack stiffness.
Sahatiya, Parikshit; Badhulika, Sushmee
2017-03-03
This paper reports a new type of electronic, recoverable skin-like pressure and strain sensor, produced on a flexible, biodegradable pencil-eraser substrate and fabricated using a solvent-free, low-cost and energy efficient process. Multi-walled carbon nanotube (MWCNT) film, the strain sensing element, was patterned on pencil eraser with a rolling pin and a pre-compaction mechanical press. This induces high interfacial bonding between the MWCNTs and the eraser substrate, which enables the sensor to achieve recoverability under ambient conditions. The eraser serves as a substrate for strain sensing, as well as acting as a dielectric for capacitive pressure sensing, thereby eliminating the dielectric deposition step, which is crucial in capacitive-based pressure sensors. The strain sensing transduction mechanism is attributed to the tunneling effect, caused by the elastic behavior of the MWCNTs and the strong mechanical interlock between MWCNTs and the eraser substrate, which restricts slippage of MWCNTs on the eraser thereby minimizing hysteresis. The gauge factor of the strain sensor was calculated to be 2.4, which is comparable to and even better than most of the strain and pressure sensors fabricated with more complex designs and architectures. The sensitivity of the capacitive pressure sensor was found to be 0.135 MPa -1 .To demonstrate the applicability of the sensor as artificial electronic skin, the sensor was assembled on various parts of the human body and corresponding movements and touch sensation were monitored. The entire fabrication process is scalable and can be integrated into large areas to map spatial pressure distributions. This low-cost, easily scalable MWCNT pin-rolled eraser-based pressure and strain sensor has huge potential in applications such as artificial e-skin in flexible electronics and medical diagnostics, in particular in surgery as it provides high spatial resolution without a complex nanostructure architecture.
Design guide for helicopter transmission seals
NASA Technical Reports Server (NTRS)
Hayden, T. S.; Keller, C. H., Jr.
1974-01-01
A detailed approach for the selection and design of seals for helicopter transmissions is presented. There are two major types of seals presently being used and they are lip type seals and mechanical type seals. Lip type seals can be divided in conventional lip seals and hydrodynamic lip seals. Conventional lip seals can be used for slow-speed, low-pressure, low-temperature sealing. Hydrodynamic lip seals although they are as pressure and temperature limited as conventional lip seals, can operate at a higher speed. Mechanical types seals are comprised of face seals and circumferential seals. Face seals are capable of high speed, high pressure, and high temperature. Circumferential seals can be used in high-speed and high-temperature applications, but will leak excessively at moderate pressures. The performance goals of transmission seals are a life that is at least equal to the scheduled overhaul interval of the gearbox component and a leakage rate of near zero.
Effects of hydrostatic pressure on mouse sperm.
Karimi, N; Kamangar, P Bahrami; Azadbakht, M; Amini, A; Amiri, I
2014-01-01
The objective of this study was to investigate the abnormalities in sperm after exposure to hydrostatic pressure. Hydrostatic pressure acting on the cells is one of the fundamental environmental mechanical forces. Disorders of relationship between the cells and this mechanical force, such as when pressure varies beyond physiological limits, can lead to disease or pathological states. Sperm exposed to different range of hydrostatic pressure within male reproductive system and after entering the female reproductive system. Sexually mature male NMRI mice, 8-12 weeks-old were sperm donors. Sperms were separated from the caudal epididymis and maintained in Ham's F-10 culture medium supplemented with 10 % FBS and divided into control and treatments. Sperm suspensions in the treatments were placed within pressure chamber and were subjected to increased hydrostatic pressure of 25, 50 and 100 mmHg (treatment I, II and III) above atmospheric pressure for 2 and 4 h. Sperm viability, motility, morphology, DNA integrity and fertilizing ability were assessed and compared with control. Results showed that hydrostatic pressure dependent on ranges and time manner reduced sperm quality due to adverse effect on viability, motility , morphology, DNA integrity and fertilizing ability in all of treatments, especially after 4h (p<0.05). Our data revealed hydrostatic pressure reduces sperm quality as a consequence of adverse effects on sperm parameters and may cause male infertility or subfertility (Tab. 5, Ref. 5).
Integrated titer plate-injector head for microdrop array preparation, storage and transfer
Swierkowski, Stefan P.
2000-01-01
An integrated titer plate-injector head for preparing and storing two-dimensional (2-D) arrays of microdrops and for ejecting part or all of the microdrops and inserting same precisely into 2-D arrays of deposition sites with micrometer precision. The titer plate-injector head includes integrated precision formed nozzles with appropriate hydrophobic surface features and evaporative constraints. A reusable pressure head with a pressure equalizing feature is added to the titer plate to perform simultaneous precision sample ejection. The titer plate-injector head may be utilized in various applications including capillary electrophoresis, chemical flow injection analysis, microsample array preparation, etc.
Thermodynamic Study of Multi Pressure HRSG in Gas/Steam Combined Cycle Power Plant
NASA Astrophysics Data System (ADS)
Sharma, Meeta; Singh, Onkar
2018-01-01
Combined cycle power plants have a combination of gas based topping cycle and steam based bottoming cycle through the use of Heat Recovery Steam Generator (HRSG). These HRSG may be either of single pressure (SP) or dual pressure (DP) or multiple pressure type. Here in this study thermodynamic analysis is carried out for optimal performance of HRSG using different types of HRSG layout for combined cycle efficiency improvement. Performance of single pressure HRSG and dual pressure HRSG, utilized in gas/steam combined cycle is analyzed and presented here. In comparison to single pressure, dual pressure HRSG offers 10 to 15% higher reduction in stack temperature due to greater heat recovery and thus improved plant efficiency.
46 CFR 38.10-5 - Filling and discharge pipes-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-closing valve shall satisfy the requirements of § 38.10-1(j). (b) For pressure vessel type tanks the... the piping enters the tank. For pressure vessel type tanks operating at low pressure and with service temperature near the cargo atmospheric boiling point, the Commandant may approve individual installations...
46 CFR 151.50-22 - Hydrochloric acid.
Code of Federal Regulations, 2013 CFR
2013-10-01
...), compressed air may be used to discharge hydrochloric acid from gravity type cargo tanks only if the tanks are of cylindrical shape with dished heads, provided the air pressure does not exceed the design pressure...) Hydrochloric acid shall be carried in gravity or pressure type cargo tanks which are independent of the vessel...
46 CFR 151.50-22 - Hydrochloric acid.
Code of Federal Regulations, 2014 CFR
2014-10-01
...), compressed air may be used to discharge hydrochloric acid from gravity type cargo tanks only if the tanks are of cylindrical shape with dished heads, provided the air pressure does not exceed the design pressure...) Hydrochloric acid shall be carried in gravity or pressure type cargo tanks which are independent of the vessel...
46 CFR 151.50-22 - Hydrochloric acid.
Code of Federal Regulations, 2012 CFR
2012-10-01
...), compressed air may be used to discharge hydrochloric acid from gravity type cargo tanks only if the tanks are of cylindrical shape with dished heads, provided the air pressure does not exceed the design pressure...) Hydrochloric acid shall be carried in gravity or pressure type cargo tanks which are independent of the vessel...
Code of Federal Regulations, 2010 CFR
2010-10-01
... respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... the facepiece shall not fall below atmospheric at inhalation airflows less than 115 liters (4 cubic...
Code of Federal Regulations, 2011 CFR
2011-10-01
... respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... the facepiece shall not fall below atmospheric at inhalation airflows less than 115 liters (4 cubic...