NASA Astrophysics Data System (ADS)
Liu, C. L.; Kirchengast, G.; Zhang, K. F.; Norman, R.; Li, Y.; Zhang, S. C.; Carter, B.; Fritzer, J.; Schwaerz, M.; Choy, S. L.; Wu, S. Q.; Tan, Z. X.
2013-09-01
Global Navigation Satellite System (GNSS) radio occultation (RO) is an innovative meteorological remote sensing technique for measuring atmospheric parameters such as refractivity, temperature, water vapour and pressure for the improvement of numerical weather prediction (NWP) and global climate monitoring (GCM). GNSS RO has many unique characteristics including global coverage, long-term stability of observations, as well as high accuracy and high vertical resolution of the derived atmospheric profiles. One of the main error sources in GNSS RO observations that significantly affect the accuracy of the derived atmospheric parameters in the stratosphere is the ionospheric error. In order to mitigate the effect of this error, the linear ionospheric correction approach for dual-frequency GNSS RO observations is commonly used. However, the residual ionospheric errors (RIEs) can be still significant, especially when large ionospheric disturbances occur and prevail such as during the periods of active space weather. In this study, the RIEs were investigated under different local time, propagation direction and solar activity conditions and their effects on RO bending angles are characterised using end-to-end simulations. A three-step simulation study was designed to investigate the characteristics of the RIEs through comparing the bending angles with and without the effects of the RIEs. This research forms an important step forward in improving the accuracy of the atmospheric profiles derived from the GNSS RO technique.
NASA Astrophysics Data System (ADS)
Liu, Congliang; Kirchengast, Gottfried; Sun, Yueqiang; Zhang, Kefei; Norman, Robert; Schwaerz, Marc; Bai, Weihua; Du, Qifei; Li, Ying
2018-04-01
The Global Navigation Satellite System (GNSS) radio occultation (RO) technique is widely used to observe the atmosphere for applications such as numerical weather prediction and global climate monitoring. The ionosphere is a major error source to RO at upper stratospheric altitudes, and a linear dual-frequency bending angle correction is commonly used to remove the first-order ionospheric effect. However, the higher-order residual ionospheric error (RIE) can still be significant, so it needs to be further mitigated for high-accuracy applications, especially from 35 km altitude upward, where the RIE is most relevant compared to the decreasing magnitude of the atmospheric bending angle. In a previous study we quantified RIEs using an ensemble of about 700 quasi-realistic end-to-end simulated RO events, finding typical RIEs at the 0.1 to 0.5 µrad noise level, but were left with 26 exceptional events with anomalous RIEs at the 1 to 10 µrad level that remained unexplained. In this study, we focused on investigating the causes of the high RIE of these exceptional events, employing detailed along-ray-path analyses of atmospheric and ionospheric refractivities, impact parameter changes, and bending angles and RIEs under asymmetric and symmetric ionospheric structures. We found that the main causes of the high RIEs are a combination of physics-based effects - where asymmetric ionospheric conditions play the primary role, more than the ionization level driven by solar activity - and technical ray tracer effects due to occasions of imperfect smoothness in ionospheric refractivity model derivatives. We also found that along-ray impact parameter variations of more than 10 to 20 m are possible due to ionospheric asymmetries and, depending on prevailing horizontal refractivity gradients, are positive or negative relative to the initial impact parameter at the GNSS transmitter. Furthermore, mesospheric RIEs are found generally higher than upper-stratospheric ones, likely due to being closer in tangent point heights to the ionospheric E layer peaking near 105 km, which increases RIE vulnerability. In the future we will further improve the along-ray modeling system to fully isolate technical from physics-based effects and to use it beyond this work for additional GNSS RO signal propagation studies.
Jung, Mi; Kim, Jae Hun; Lee, Seok; Jang, Byung Jin; Lee, Woo Young; Oh, Yoo-Mi; Park, Sun-Woo; Woo, Deokha
2012-07-01
A significant enhancement in the light output from nano-patterned InP substrate covered with a nanoporous alumina mask was observed. A uniform nanohole array on an InP semiconductor substrate was fabricated by inductively coupled plasma reactive ion etching (ICP-RIE), using the nanoporous alumina mask as a shadow mask. The light output property of the semiconductor substrate was investigated via photoluminescence (PL) intensity measurement. The InP substrate with a nanohole array showed a more enhanced PL intensity compared with the raw InP substrate without a nanohole structure. After ICP-RIE etching, the light output from the nanoporous InP substrate covered with a nanoporous alumina mask showed fourfold enhanced PL intensity compared with the raw InP substrate. These results can be used as a prospective method for increasing the light output efficiency of optoelectronic devices.
Characterization and application of a laser-driven intense pulsed neutron source using Trident
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vogel, Sven C.
A team of Los Alamos researchers supported a final campaign to use the Trident laser to produce neutrons, contributed their multidisciplinary expertise to experimentally assess if laser-driven neutron sources can be useful for MaRIE. MaRIE is the Laboratory’s proposed experimental facility for the study of matter-radiation interactions in extremes. Neutrons provide a radiographic probe that is complementary to x-rays and protons, and can address imaging challenges not amenable to those beams. The team's efforts characterize the Laboratory’s responsiveness, flexibility, and ability to apply diverse expertise where needed to perform successful complex experiments.
2016-05-09
inflammation. Author Summary A recent approach to quantitatively characterize the timing and intensity of the inflamma- tory response relies on the use of...Fig 1). The quantitative properties of these trajecto- ries vary as a result of differences in inflammatory conditions and scenarios. Recently, four... quantitative indices [namely, peak height (Cmax), activation time (Tact), resolution interval (Ri), and resolution plateau (Rp)] (Fig 1) were introduced
RIES - Rijnland Internet Election System: A Cursory Study of Published Source Code
NASA Astrophysics Data System (ADS)
Gonggrijp, Rop; Hengeveld, Willem-Jan; Hotting, Eelco; Schmidt, Sebastian; Weidemann, Frederik
The Rijnland Internet Election System (RIES) is a system designed for voting in public elections over the internet. A rather cursory scan of the source code to RIES showed a significant lack of security-awareness among the programmers which - among other things - appears to have left RIES vulnerable to near-trivial attacks. If it had not been for independent studies finding problems, RIES would have been used in the 2008 Water Board elections, possibly handling a million votes or more. While RIES was more extensively studied to find cryptographic shortcomings, our work shows that more down-to-earth secure design practices can be at least as important, and the aspects need to be examined much sooner than right before an election.
NASA Astrophysics Data System (ADS)
Yamamoto, Akio; Makino, Shinya; Kanatani, Keito; Kuzuhara, Masaaki
2018-04-01
In this study, the metal-organic-vapor-phase-epitaxial growth behavior and electrical properties of AlGaN/GaN structures prepared by the growth of an AlGaN layer on a reactive-ion-etched (RIE) GaN surface without regrown GaN layers were investigated. The annealing of RIE-GaN surfaces in NH3 + H2 atmosphere, employed immediately before AlGaN growth, was a key process in obtaining a clean GaN surface for AlGaN growth, that is, in obtaining an electron mobility as high as 1350 cm2 V-1 s-1 in a fabricated AlGaN/RIE-GaN structure. High-electron-mobility transistors (HEMTs) were successfully fabricated with AlGaN/RIE-GaN wafers. With decreasing density of dotlike defects observed on the surfaces of AlGaN/RIE-GaN wafers, both two-dimensional electron gas properties of AlGaN/RIE-GaN structures and DC characteristics of HEMTs were markedly improved. Since dotlike defect density was markedly dependent on RIE lot, rather than on growth lot, surface contaminations of GaN during RIE were believed to be responsible for the formation of dotlike defects and, therefore, for the inferior electrical properties.
Huang, Yi-Wen; Chuang, Chun-Yi; Hsieh, Yih-Shou; Chen, Pei-Ni; Yang, Shun-Fa; Shih-Hsuan-Lin; Chen, Yang-Yu; Lin, Chiao-Wen; Chang, Yu-Chao
2017-03-01
Raspberries (Rubus idaeus L.) have been extensively studies worldwide because of their beneficial effects on health. Recently reports indicate that crude extracts of Rubus idaeus (RIE) have antioxidant and anticancer ability. The aim of this study was to evaluate the mechanism of its antimetastatic ability in oral cancer cells. In this study, SCC-9 and SAS oral cancer cells were subjected to a treatment with RIE and then analyzed the effect of RIE on migration and invasion. The addition of RIE inhibited the migration and invasion ability of oral cancer cells. Real time PCR, western blot and zymography analysis demonstrated that mRNA, protein expression and enzyme activity of matrix metalloproteinases-2 (MMP-2) were down-regulated by RIE. Moreover, the phosphorylation of Focal adhesion kinase (FAK), src, and extracellular signal-regulated kinase (ERK) were inhibited after RIE treatment. In conclusion, these results demonstrated that RIE exerted an inhibitory effect of migration and invasion in oral cancer cells and alter metastasis by suppression of MMP-2 expression through FAK/Scr/ERK signaling pathway. © 2016 Wiley Periodicals, Inc. Environ Toxicol 32: 1037-1046, 2017. © 2016 Wiley Periodicals, Inc.
MaRIE theory, modeling and computation roadmap executive summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lookman, Turab
The confluence of MaRIE (Matter-Radiation Interactions in Extreme) and extreme (exascale) computing timelines offers a unique opportunity in co-designing the elements of materials discovery, with theory and high performance computing, itself co-designed by constrained optimization of hardware and software, and experiments. MaRIE's theory, modeling, and computation (TMC) roadmap efforts have paralleled 'MaRIE First Experiments' science activities in the areas of materials dynamics, irradiated materials and complex functional materials in extreme conditions. The documents that follow this executive summary describe in detail for each of these areas the current state of the art, the gaps that exist and the road mapmore » to MaRIE and beyond. Here we integrate the various elements to articulate an overarching theme related to the role and consequences of heterogeneities which manifest as competing states in a complex energy landscape. MaRIE experiments will locate, measure and follow the dynamical evolution of these heterogeneities. Our TMC vision spans the various pillar science and highlights the key theoretical and experimental challenges. We also present a theory, modeling and computation roadmap of the path to and beyond MaRIE in each of the science areas.« less
NASA Astrophysics Data System (ADS)
Djellit, Hamou; Henry, Bernard; Derder, Mohamed E. M.
In the western Ahaggar shield, the transition between the Precambrian and the Ordovician units is characterised by thick volcano-sedimentary series ('Série pourprée' of the Ahnet). This series, in part of Cambrian age, results from the demolition of the Panafrican belt. Similar series were known in grabens located between the West African craton and the Ahaggar, from the 'Adrar des Iforas', in the south, to the Ougarta belt, in the north. We describe in this study a new formation identical to the 'Série pourprée' of the Ahnet, but cropping out in the far Southeast of the Ahaggar (In Guezzam). This new datum improves the Panafrican belt configuration. To cite this article: H. Djellit et al., C. R. Geoscience 334 (2002) 789-794.
Ke, Lijing; Wen, Teng; Bradshaw, Jeremy P; Zhou, Jianwu; Rao, Pingfan
2012-01-01
The aim of this study is to elucidate how the Isatidis Radix (板藍根 bǎn lán gēn) tonic, as an aqueous mixture of hundreds of compositions, interrupts the infection of influenza viruses to their host cells. The efficacy of the tonic was evaluated and expressed as cell proliferation rate and plaque reduction rate in Madin-Darby Canine Kidney (MDCK) cells, against 3 strains of influenza A and B viruses. This boiling water (at 100°C) extract of Isatidis Radix (RIE) showed antiviral activity against influenza virus A and B. The concentration for 50% inhibition of influenza virus A replication (IC50) in MDCK cell was 12.6 mg/mL with a therapeutic index >8. When cells were incubated with RIE prior to virus adsorption, the numbers of viable cell were at least doubled compared to the numbers of virus control, RIE incubation after virus adsorption and RIE incubation with virus prior to adsorption, in both influenza virus A and B. Moreover, much less virus particles were spotted by scanning electron microscope (SEM) in the RIE pre-treated cells than the cells without RIE treatment. These results indicate the antiviral activity of RIE is mainly attributed to its host cell protection effect but not actions on virus or post-virus-adsorption interruption. Cell, but not virus, is more likely to be the action target of RIE. PMID:24716114
MaRIE: an experimental facility concept revolutionizing materials in extremes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris W
The Matter-Radiation Interactions in Extremes (MaRIE) project intends to create an experimental facility that will revolutionize the control of materials in extremes. That control extends to extreme regimes where solid material has failed and begins to flow - the regimes of fluid dynamics and turbulent mixing. This presentation introduces the MaRIE facility concept, demonstrates examples of the science case that determine its functional requirements, and kicks-off the discussion of the decadal scientific challenges of mixing in extremes, including those MaRIE might address.
The Mesoscale Science of the Matter-Radiation Interactions in Extremes (MaRIE) project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kippen, Karen Elizabeth; Montoya, Donald Raymond
The National Nuclear Security Administration (NNSA) requires the ability to understand and test how material structures, defects, and interfaces determine performance in extreme environments such as in nuclear weapons. To do this, MaRIE will be an x-ray source that is laser-like and brilliant with very fl exible and fast pulses to see at weapons-relevant time scales, and with high enough energy to study critical materials. The Department of Energy (DOE) has determined there is a mission need for MaRIE to deliver this capability. MaRIE can use some of the existing infrastructure of the Los Alamos Neutron Science Center (LANSCE) andmore » its accelerator capability. MaRIE will be built as a strategic partnership of DOE national laboratories and university collaborators.« less
2013-02-01
leukocyte esterase in the diagnosis of urinary tract infection may be higher in patients of an underserved population, who tend to receive evaluation...Crit Care. 2001;5(4):184–8. 4. Lawless ST. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med. 1994;22:981–5. 5. Wald A...after traumatic inju- ries: a predictor of mortality? J Emerg Med. 2003;25:175–9. 22. Lipsky AM, Gausche-Hill M, Henneman PL, et al. Prehospital
Fu, Zhenrong; Lin, Lan; Tian, Miao; Wang, Jingxuan; Zhang, Baiwen; Chu, Pingping; Li, Shaowu; Pathan, Muhammad Mohsin; Deng, Yulin; Wu, Shuicai
2017-11-01
The development of genetically engineered mouse models for neuronal diseases and behavioural disorders have generated a growing need for small animal imaging. High-resolution magnetic resonance microscopy (MRM) provides powerful capabilities for noninvasive studies of mouse brains, while avoiding some limits associated with the histological procedures. Quantitative comparison of structural images is a critical step in brain imaging analysis, which highly relies on the performance of image registration techniques. Nowadays, there is a mushrooming growth of human brain registration algorithms, while fine-tuning of those algorithms for mouse brain MRMs is rarely addressed. Because of their topology preservation property and outstanding performance in human studies, diffeomorphic transformations have become popular in computational anatomy. In this study, we specially tuned five diffeomorphic image registration algorithms [DARTEL, geodesic shooting, diffeo-demons, SyN (Greedy-SyN and geodesic-SyN)] for mouse brain MRMs and evaluated their performance using three measures [volume overlap percentage (VOP), residual intensity error (RIE) and surface concordance ratio (SCR)]. Geodesic-SyN performed significantly better than the other methods according to all three different measures. These findings are important for the studies on structural brain changes that may occur in wild-type and transgenic mouse brains. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
Hsieh, Yih-Shou; Chu, Shu-Chen; Hsu, Li-Sung; Chen, Kuo-Shuen; Lai, Ming-Tsung; Yeh, Chia-Heng; Chen, Pei-Ni
2013-12-01
Epithelial to mesenchymal transition (EMT) has been considered essential for cancer metastasis, a multistep complicated process including local invasion, intravasation, extravasation, and proliferation at distant sites. Herein we provided molecular evidence associated with the antimetastatic effect of Rubus idaeus L. extracts (RIE) by showing a nearly complete inhibition on the invasion (p<0.001) of highly metastatic A549 cells via reduced activities of matrix metalloproteinase-2 (MMP-2) and urokinasetype plasminogen activator (u-PA). We performed Western blot to find that RIE could induce up-regulation of epithelial marker such as E-cadherin and α-catenin and inhibit the mesenchymal markers such as N-cadherin, fibronectin, snail-1, and vimentin. Selective snail-1 inhibition by snail-1-specific-siRNA also showed increased E-cadherin expression in A549 cells suggesting a possible involvement of snail-1 inhibition in RIE-caused increase in E-cadherin level. RIE also inhibited p-FAK, p-paxillin and AP-1 by Western blot analysis, indicating the anti-EMT effect of RIE in human lung carcinoma. Importantly, an in vivo BALB/c nude mice xenograft model showed that RIE treatment reduced tumor growth by oral gavage, and RIE represent promising candidates for future phytochemical-based mechanistic pathway-targeted cancer prevention strategies. Copyright © 2013 Elsevier Ltd. All rights reserved.
MaRIE: Probing Dynamic Processes in Soft Materials Using Advanced Light Sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sykora, Milan; Kober, Edward Martin
Los Alamos National Laboratory has developed a concept for a new research facility, MaRIE: Matter-Radiation Interactions in Extremes. The key motivation for MaRIE is to develop new experimental capabilities needed to fill the existing gaps in our fundamental understanding of materials important for key National Nuclear Security Agency (NNSA) goals. MaRIE will bring two major new capabilities: (a) the ability to characterize the meso- and microstructure of materials in bulk as well as local dynamic response characteristics, and (b) the ability to characterize how this microstructure evolves under NNSA-relevant conditions and impacts the material’s performance in this regime.
Hsin, Chung-Han; Huang, Cheng-Chen; Chen, Pei-Ni; Hsieh, Yih-Shou; Yang, Shun-Fa; Ho, Yu-Ting; Lin, Chiao-Wen
2017-01-01
Nasopharyngeal carcinoma (NPC) is characterized by a high incidence of metastasis in the neck lymph nodes, resulting in a poor prognosis and posing challenges for treatment. In this study, we investigated the in vitro antimetastatic properties of Rubus idaeus extract (RIE) on human nasopharyngeal carcinoma cells. HONE-1, NPC-39 and NPC-BM cells were subjected to RIE treatment, and effects on the migration and invasion of tumor cells were analyzed. The results showed that RIE suppressed the migration and invasion of NPC cells. Gelatin zymography assay, Western blotting and real-time PCR showed that matrix metalloproteinases-2 (MMP-2) enzyme activity, protein expression and mRNA levels were down-regulated by RIE treatment. To identify the signaling pathway, mitogen-activated protein kinase proteins were examined, which showed that phosphorylation of ERK1/2 was inhibited after the treatment of RIE. In summary, our data showed that RIE inhibited the migration and invasion of NPC cells by suppressing the expression of MMP-2 by down-regulating the ERK1/2 signaling pathway, suggesting that Rubus idaeus may serve as chemotherapeutic and chemopreventive agent for NPC.
NASA Astrophysics Data System (ADS)
Janik, Monika; Koba, Marcin; Celebańska, Anna; Bock, Wojtek J.; Śmietana, Mateusz
2018-07-01
In this work, we discuss an application of reactive ion etching (RIE) for enhancing the sensing properties of a micro-cavity in-line Mach-Zehnder interferometer (μIMZI). The μIMZI was fabricated using femtosecond laser micromachining in a standard single-mode fiber as a circular hole with a diameter of 54 μm. Next, the structures underwent two kinds of RIE using as reactive gases: sulfur hexafluoride (SF6) and oxygen (O2) mixtures (SF6/O2) or O2 itself. When RIE with SF6/O2 was applied, it allowed for an efficient and well-controlled etching of the fabricated structure at nanometers level observed as an increase in spectral depths of the minima in the μIMZI transmission spectrum. A similar RIE process with O2 alone was ineffective. The well-defined minima obtained with the SF6/O2 RIE significantly improved the resolution of measurements made with the μIMZI. The effect was demonstrated for high-resolution refractive index (RI) measurements of liquids in the cavity. The result of the RIE process was to clean the micro-cavity bottom, increase its depth, and smooth its sidewalls. As an additional effect, the wettability of the micro-cavity surface was improved, making the RI measurements faster and more repeatable. Moreover, we demonstrated that RIE with SF6/O2 results in more stable wettability improvement than when O2 is applied as a reactive gas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiaoyu, E-mail: xiaoyu.yang@wdc.com; Chen, Lifan; Han, Hongmei
The impact of the fluorine-based reactive ion etch (RIE) process on the structural, electrical, and magnetic properties of NiFe and CoNiFe-plated materials was investigated. Several techniques, including X-ray fluorescence, 4-point-probe, BH looper, transmission electron microscopy (TEM), and electron energy loss spectroscopy (EELS), were utilized to characterize both bulk film properties such as thickness, average composition, Rs, ρ, Bs, Ms, and surface magnetic “dead” layers' properties such as thickness and element concentration. Experimental data showed that the majority of Rs and Bs changes of these bulk films were due to thickness reduction during exposure to the RIE process. ρ and Msmore » change after taking thickness reduction into account were negligible. The composition of the bulk films, which were not sensitive to surface magnetic dead layers with nano-meter scale, showed minimum change as well. It was found by TEM and EELS analysis that although both before and after RIE there were magnetic dead layers on the top surface of these materials, the thickness and element concentration of the layers were quite different. Prior to RIE, dead layer was actually native oxidation layers (about 2 nm thick), while after RIE dead layer consisted of two sub-layers that were about 6 nm thick in total. Sub-layer on the top was native oxidation layer, while the bottom layer was RIE “damaged” layer with very high fluorine concentration. Two in-situ RIE approaches were also proposed and tested to remove such damaged sub-layers.« less
Aquisição de Estreptococos Mutans e Desenvolvimento de Cárie Dental em Primogênitos
NOCE, Erica; RUBIRA, Cassia Maria Fischer; da Silva ROSA, Odila Pereira; da SILVA, Salete Moura Bonifácio; BRETZ, Walter Antonio
2011-01-01
Objetivo Avaliar o momento de aquisição de estreptococos mutans (EM), desenvolvimento de cárie dental e as variáveis a eles associadas no decorrer de 23 meses, em primogênitos de famílias de baixo nível socioeconômico, desde os sete meses de idade. Método A amostra foi selecionada com base em mães densamente colonizadas por EM, incluindo todos os membros de 14 famílias que conviviam na mesma casa. Foram envolvidos no estudo 14 mães, pais e primogênitos e 8 parentes, na maioria avós. Exames clínicos e radiográficos iniciais determinaram os índices de cárie e condição periodontal dos adultos. Contagens de EM foram feitas em todos os adultos nas duas primeiras visitas. Nas crianças foram avaliados os níveis de EM, o número de dentes e de cáries, em quatro visitas. Resultados A prevalência de EM nos adultos foi alta, estando ausente em apenas um dos pais. EM foram detectados em 1, 2, 3 e 10 crianças, respectivamente nas visitas #1, 2, 3 e 4. A cárie dental foi detectada em apenas três crianças na última visita (aos 30 meses de idade), as quais apresentaram escores de EM significantemente maiores que as crianças sem cárie, na mesma visita. Conclusão Exclusivamente a condição social de baixa renda e mães densamente colonizadas por EM não são sinônimo de colonização precoce e alta atividade de cárie em crianças cuidadas em casa. O desenvolvimento de cárie está significantemente associado a escores elevados de EM nas crianças. PMID:22022218
Cooperative simulation of lithography and topography for three-dimensional high-aspect-ratio etching
NASA Astrophysics Data System (ADS)
Ichikawa, Takashi; Yagisawa, Takashi; Furukawa, Shinichi; Taguchi, Takafumi; Nojima, Shigeki; Murakami, Sadatoshi; Tamaoki, Naoki
2018-06-01
A topography simulation of high-aspect-ratio etching considering transports of ions and neutrals is performed, and the mechanism of reactive ion etching (RIE) residues in three-dimensional corner patterns is revealed. Limited ion flux and CF2 diffusion from the wide space of the corner is found to have an effect on the RIE residues. Cooperative simulation of lithography and topography is used to solve the RIE residue problem.
Sun, Laixi; Shao, Ting; Shi, Zhaohua; Huang, Jin; Ye, Xin; Jiang, Xiaodong; Wu, Weidong; Yang, Liming; Zheng, Wanguo
2018-01-01
The reactive ion etching (RIE) process of fused silica is often accompanied by surface contamination, which seriously degrades the ultraviolet laser damage performance of the optics. In this study, we find that the contamination behavior on the fused silica surface is very sensitive to the RIE process which can be significantly optimized by changing the plasma generating conditions such as discharge mode, etchant gas and electrode material. Additionally, an optimized RIE process is proposed to thoroughly remove polishing-introduced contamination and efficiently prevent the introduction of other contamination during the etching process. The research demonstrates the feasibility of improving the damage performance of fused silica optics by using the RIE technique. PMID:29642571
Using superconducting undulator for enhanced imaging capabilities of MaRIE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yampolsky, Nikolai
MaRIE x-ray free electron laser (FEL) is envisioned to deliver a burst of closely spaced in time pulses for enabling the capability of studying the dynamic processes in a sample. MaRIE capability can be largely enhanced using the superconducting undulator, which has the capability of doubling its period. This technology will allow reaching the photon energy as low as ~200-500 eV. As a result, the MaRIE facility will have a broader photon energy range enabling a larger variety of experiments. The soft x-ray capability is more likely to achieve the 3D imaging of dynamic processes in noncrystal materials than themore » hard x-ray capability alone.« less
MaRIE Undulator & XFEL Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, Dinh Cong; Marksteiner, Quinn R.; Anisimov, Petr Mikhaylovich
The 22 slides in this presentation treat the subject under the following headings: MaRIE XFEL Performance Parameters, Input Electron Beam Parameters, Undulator Design, Genesis Simulations, Risks, and Summary It is concluded that time-dependent Genesis simulations show the MaRIE XFEL can deliver the number of photons within the required bandwidth, provided a number of assumptions are met; the highest risks are associated with the electron beam driving the XFEL undulator; and risks associated with the undulator and/or distributed seeding technique may be evaluated or retired by performing early validation experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Han-Soo; Kim, Ju Won; Gang, Jingu
2006-09-15
LB42708 (LB7) and LB42908 (LB9) are pyrrole-based orally active farnesyltransferase inhibitors (FTIs) that have similar structures. The in vitro potencies of these compounds against FTase and GGTase I are remarkably similar, and yet they display different activity in apoptosis induction and morphological reversion of ras-transformed rat intestinal epithelial (RIE) cells. Both FTIs induced cell death despite K-ras prenylation, implying the participation of Ras-independent mechanism(s). Growth inhibition by these two FTIs was accompanied by G1 and G2/M cell cycle arrests in H-ras and K-ras-transformed RIE cells, respectively. We identified three key markers, p21{sup CIP1/WAF1}, RhoB and EGFR, that can explain themore » differences in the molecular mechanism of action between two FTIs. Only LB7 induced the upregulation of p21{sup CIP1/WAF1} and RhoB above the basal level that led to the cell cycle arrest and to distinct morphological alterations of ras-transformed RIE cells. Both FTIs successfully inhibited the ERK and activated JNK in RIE/K-ras cells. While the addition of conditioned medium from RIE/K-ras reversed the growth inhibition of ras-transformed RIE cells by LB9, it failed to overcome the growth inhibitory effect of LB7 in both H-ras- and K-ras-transformed RIE cells. We found that LB7, but not LB9, decreased the expression of EGFRs that confers the cellular unresponsiveness to EGFR ligands. These results suggest that LB7 causes the induction of p21{sup CIP1/WAF1} and RhoB and downregulation of EGFR that may serve as critical steps in the mechanism by which FTIs trigger irreversible inhibitions on the cell growth and apoptosis in ras-transformed cells.« less
RIE-based Pattern Transfer Using Nanoparticle Arrays as Etch Masks
NASA Astrophysics Data System (ADS)
Hogg, Chip; Majetich, Sara A.; Bain, James A.
2009-03-01
Nanomasking is used to transfer the pattern of a self-assembled array of nanoparticles into an underlying thin film, for potential use as bit-patterned media. We have used this process to investigate the limits of pattern transfer, as a function of gap size in the pattern. Reactive Ion Etching (RIE) is our chosen process, since the gaseous reaction products and high chemical selectivity are ideal features for etching very small gaps. Interstitial surfactant is removed with an O2 plasma, allowing the etchants to penetrate between the particles. Their pattern is transferred into an intermediate SiO2 mask using a CH4-based RIE. This patterned SiO2 layer is finally used as a mask for the MeOH-based RIE which patterns the magnetic film. We present cross-sectional TEM characterization of the etch profiles, as well as magnetic characterization of the film before and after patterning.
Enhanced light absorption of solar cells and photodetectors by diffraction
Zaidi, Saleem H.; Gee, James M.
2005-02-22
Enhanced light absorption of solar cells and photodetectors by diffraction is described. Triangular, rectangular, and blazed subwavelength periodic structures are shown to improve performance of solar cells. Surface reflection can be tailored for either broadband, or narrow-band spectral absorption. Enhanced absorption is achieved by efficient optical coupling into obliquely propagating transmitted diffraction orders. Subwavelength one-dimensional structures are designed for polarization-dependent, wavelength-selective absorption in solar cells and photodetectors, while two-dimensional structures are designed for polarization-independent, wavelength-selective absorption therein. Suitable one and two-dimensional subwavelength periodic structures can also be designed for broadband spectral absorption in solar cells and photodetectors. If reactive ion etching (RIE) processes are used to form the grating, RIE-induced surface damage in subwavelength structures can be repaired by forming junctions using ion implantation methods. RIE-induced surface damage can also be removed by post RIE wet-chemical etching treatments.
NASA Astrophysics Data System (ADS)
Schmieder, Martin; Kennedy, Trudi; Jourdan, Fred; Buchner, Elmar; Reimold, Wolf Uwe
2018-01-01
40Ar/39Ar dating of specimens of moldavite, the formation of which is linked to the Ries impact in southern Germany, with a latest-generation ARGUS VI multi-collector mass spectrometer yielded three fully concordant plateau ages with a weighted mean age of 14.808 ± 0.021 Ma (± 0.038 Ma including all external uncertainties; 2σ; MSWD = 0.40, P = 0.67). This new best-estimate age for the Nördlinger Ries is in general agreement with previous 40Ar/39Ar results for moldavites, but constitutes a significantly improved precision with respect to the formation age of the distal Ries-produced tektites. Separates of impact glass from proximal Ries ejecta (suevite glass from three different surface outcrops) and partially melted feldspar particles from impact melt rock of the SUBO 18 Enkingen drill core failed to produce meaningful ages. These glasses show evidence for excess 40Ar introduction, which may have been incurred during interaction with hydrothermal fluids. Only partially reset 40Ar/39Ar ages could be determined for the feldspathic melt separates from the Enkingen core. The new 40Ar/39Ar results for the Ries impact structure constrain the duration of crater cooling, during the prevailing hydrothermal activity, to locally at least ∼60 kyr. With respect to the dating of terrestrial impact events, this paper briefly discusses a number of potential issues and effects that may be the cause for seemingly precise, but on a kyr-scale inaccurate, impact ages.
NASA Astrophysics Data System (ADS)
Pietrek, Alexa; Kenkmann, Thomas
2016-07-01
We reassessed two drill cores of the Bunte Breccia deposits of the Ries crater, Germany. The objectives of our study were the documentation of evidence for water in the Bunte Breccia, the evaluation of how that water influenced the emplacement processes, and from which preimpact water reservoir it was derived. The Bunte Breccia in both cores can be structured into a basal layer composed mainly of local substrate material, overlain by texturally and compositionally diverse, crater-derived breccia units. The basal layer is composed of the youngest sediments (Tertiary clays and Upper Jurassic limestone) and has a razor-sharp boundary to the upper breccia units, which are composed of older rocks of Upper Jurassic to Upper Triassic age. Sparse material exchange occurred between the basal layer and the rest of the Bunte Breccia. Fluids predominantly came from the Tertiary and the Upper Triassic sandstone formation. In the basal layer, Tertiary clays were subjected to intense, ductile deformation, indicating saturation with water. This suggests that water was mixed into the matrix, creating a fluidized basal layer with a strong shear localization. In the upper units, Upper Triassic sandstones are intensely deformed by granular flow. The texture requires that the rocks were disaggregated into granular sand. Vaporization of pore water probably aided fragmentation of these rocks. In the Otting core, hot suevite (T > 600 °C) covered the Bunte Breccia shortly after its emplacement. Vertically oriented gas escape pipes in suevite partly emanate directly at the contact to the Bunte Breccia. They indicate that the Bunte Breccia contained a substantial amount of water in the upper part that was vaporized and escaped through these vents.
Resources in Education (RIE). Volume 36, Number 11.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 12.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community, including researchers, teachers, students, school board members, school administrators, counselors, parents, etc. Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 10.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 7.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 2.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 5.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 3.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 9.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 8.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 4.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 1.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resources in Education (RIE). Volume 36, Number 6.
ERIC Educational Resources Information Center
Resources in Education, 2001
2001-01-01
"Resources in Education" (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, parents, etc.). Each issue announces approximately 1000 documents and provides…
Resonance interatomic energy in a Schwarzschild spacetime
NASA Astrophysics Data System (ADS)
Zhou, Wenting; Yu, Hongwei
2017-08-01
We study, in the Schwarzschild spacetime, the resonance interatomic energy (RIE) of two static identical atoms with an interatomic separation L along the radial direction and correlated by a symmetric/antisymmetric entangled state. The atoms are assumed to be coupled to massless scalar fields in the Boulware, Unruh, and Hartle-Hawking vacua, and approximate analytical results are obtained both at infinity and near the horizon. Our results show that at infinity, the RIE approaches that in a flat spacetime, while, near the horizon, they can deviate dramatically from each other. Besides, different from other atomic radiative properties such as the Lamb shift of a single atom or the interatomic energy between two uncorrelated atoms, which can be obviously affected by the thermal character of quantum fields, the RIE of two atoms in a symmetric/antisymmetric entangled state in the Boulware, Unruh, and Hartle-Hawking vacua are exactly the same as a result of the fact that the RIE of two such atoms depends only on the atomic self-reaction, i.e., it does not feel the vacuum fluctuations. This suggests that the RIE of two static atoms in a symmetric/antisymmetric entangled state outside a black hole is oblivious to the Hawking radiation, in contrast to those uncorrelated atoms.
Resources in Education (RIE). Volume 27, Number 10.
ERIC Educational Resources Information Center
Resources in Education, 1992
1992-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 8.
ERIC Educational Resources Information Center
Resources in Education, 1992
1992-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 6.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 9.
ERIC Educational Resources Information Center
Resources in Education, 1992
1992-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 8.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 5.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 2.
ERIC Educational Resources Information Center
Resources in Education, 1991
1991-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 12.
ERIC Educational Resources Information Center
Resources in Education, 1992
1992-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 1.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 7.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 11.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 3.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 3.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 9.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 10.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 1.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 2.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 4.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 2.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 7.
ERIC Educational Resources Information Center
Resources in Education, 1992
1992-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 29, Number 1.
ERIC Educational Resources Information Center
Resources in Education, 1994
1994-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 6.
ERIC Educational Resources Information Center
Resources in Education, 1991
1991-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 7.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 9.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 5.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 3.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 24, Number 12.
ERIC Educational Resources Information Center
Resources in Education, 1989
1989-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 12.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 10.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 11.
ERIC Educational Resources Information Center
Resources in Education, 1992
1992-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 1.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 5.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 10.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 24, Number 10.
ERIC Educational Resources Information Center
Resources in Education, 1989
1989-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 29, Number 2.
ERIC Educational Resources Information Center
Resources in Education, 1994
1994-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 9.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 4.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 7.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 6.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 4.
ERIC Educational Resources Information Center
Resources in Education, 1991
1991-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 27, Number 4.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 24, Number 11.
ERIC Educational Resources Information Center
Resources in Education, 1989
1989-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 8.
ERIC Educational Resources Information Center
ERIC Processing and Reference Facility, Rockville, MD.
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 26, Number 3.
ERIC Educational Resources Information Center
Resources in Education, 1991
1991-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 28, Number 6.
ERIC Educational Resources Information Center
Resources in Education, 1993
1993-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 2.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Resources in Education (RIE). Volume 25, Number 8.
ERIC Educational Resources Information Center
Resources in Education, 1990
1990-01-01
Resources in Education (RIE) is a monthly abstract journal that announces (catalogs, indexes, abstracts) documents of interest to the educational community (including researchers, teachers, students, school board members, school administrators, counselors, etc.). Each issue announces approximately 1,100 documents and provides indexes by Subject,…
Evaluation of species-dependent detection efficiencies in the aerosol mass spectrometer
USDA-ARS?s Scientific Manuscript database
Mass concentrations of chemical species calculated from the aerosol mass spectrometer (AMS) depend on two factors: particle collection efficiency (CE) and relative ionization efficiency (RIE, relative to the primary calibrant ammonium nitrate). While previous studies have characterized CE, RIE is re...
A Short Bibliography on Library/Media Leadership.
ERIC Educational Resources Information Center
Stanford Univ., CA. ERIC Clearinghouse on Information Resources.
Prepared for distribution at the 1975 Annual Convention of the Association for Educational Communications and Technology, this bibliography was assembled from the Current Index to Journals in Education (CIJE) and Resources in Education (RIE) computer files of the Educational Resources Information Center (ERIC). Annotated CIJE and RIE entries…
Evaluation and Applications of the Prediction of Intensity Model Error (PRIME) Model
NASA Astrophysics Data System (ADS)
Bhatia, K. T.; Nolan, D. S.; Demaria, M.; Schumacher, A.
2015-12-01
Forecasters and end users of tropical cyclone (TC) intensity forecasts would greatly benefit from a reliable expectation of model error to counteract the lack of consistency in TC intensity forecast performance. As a first step towards producing error predictions to accompany each TC intensity forecast, Bhatia and Nolan (2013) studied the relationship between synoptic parameters, TC attributes, and forecast errors. In this study, we build on previous results of Bhatia and Nolan (2013) by testing the ability of the Prediction of Intensity Model Error (PRIME) model to forecast the absolute error and bias of four leading intensity models available for guidance in the Atlantic basin. PRIME forecasts are independently evaluated at each 12-hour interval from 12 to 120 hours during the 2007-2014 Atlantic hurricane seasons. The absolute error and bias predictions of PRIME are compared to their respective climatologies to determine their skill. In addition to these results, we will present the performance of the operational version of PRIME run during the 2015 hurricane season. PRIME verification results show that it can reliably anticipate situations where particular models excel, and therefore could lead to a more informed protocol for hurricane evacuations and storm preparations. These positive conclusions suggest that PRIME forecasts also have the potential to lower the error in the original intensity forecasts of each model. As a result, two techniques are proposed to develop a post-processing procedure for a multimodel ensemble based on PRIME. The first approach is to inverse-weight models using PRIME absolute error predictions (higher predicted absolute error corresponds to lower weights). The second multimodel ensemble applies PRIME bias predictions to each model's intensity forecast and the mean of the corrected models is evaluated. The forecasts of both of these experimental ensembles are compared to those of the equal-weight ICON ensemble, which currently provides the most reliable forecasts in the Atlantic basin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris William; Barber, John L.; Kober, Edward Martin
The Matter-Radiation Interactions in Extremes project will build the experimental facility for the time-dependent control of dynamic material performance. An x-ray free electron laser at up to 42-keV fundamental energy and with photon pulses down to sub-nanosecond spacing, MaRIE 1.0 is designed to meet the challenges of time-dependent mesoscale materials science. Those challenges will be outlined, the techniques of coherent diffractive imaging and dynamic polycrystalline diffraction described, and the resulting requirements defined for a coherent x-ray source. The talk concludes with the role of the MaRIE project and science in the future.
Rural Career Guidance: Abstracts of Current Research, Materials, and Practices.
ERIC Educational Resources Information Center
Far West Lab. for Educational Research and Development, San Francisco, CA.
The annotated bibliography provides a guide to the latest resource material, research findings, and/or developments in rural career guidance found in the ERIC system. Section I contains 158 citations and abstracts which have appeared in "Resources in Education" (RIE). RIE document resumes include the ERIC accession number, author(s), title,…
Asset Management Process (AMP) Improvement Project: Final Report of Findings and Recommendations
2009-10-01
cannibalized components could no longer be sighted due to their re-use in other systems or equipment. Solution — A Rapid Improvement Event, or Kaizen , was...Property Loss Reporting domain’s lifecycle, the Green Belt recognized the opportunity for a Rapid Improvement Event (RIE), or Kaizen . A five-day RIE was
El, Goresy A.; Chao, E.C.T.
1976-01-01
Fe-Cr-Ni particles and veinlets have been discovered in the top 15 m of the compressed zone with abundant shatter cones below the bottom of the Ries crater. The metallic particles are less than a few microns across. They occur in various minerals along healed intergranular and locally in intragranular microfractures in quartz diorite, amphibolite and chloritized granite of the basement crystalline rocks. The particles consist of major Fe, Cr, and Ni with minor Si and Ca. Origin due to contamination is absolutely ruled out. We believe that these Fe-Cr-Ni particles are probably condensed from the vaporized impacting body which produced the Ries crater. These particles were injected with high velocity into microfractures near the top of the compressed zone, implanted in and across various minerals before these microfractures were resealed. The presence of Si and Ca as well as the fact that the Cr content is nearly twice that of Ni, led us to conclude that the Ries impacting body is very likely not an iron meteorite but a stony meteorite. ?? 1976.
NASA Astrophysics Data System (ADS)
Myers, John N.; Zhang, Xiaoxian; Huang, Huai; Shobha, Hosadurga; Grill, Alfred; Chen, Zhan
2017-05-01
Molecular structures at the surface and buried interface of an amorphous ultralow-k pSiCOH dielectric film were quantitatively characterized before and after reactive ion etching (RIE) and subsequent dielectric repair using sum frequency generation (SFG) vibrational spectroscopy and Auger electron spectroscopy. SFG results indicated that RIE treatment of the pSiCOH film resulted in a depletion of ˜66% of the surface methyl groups and changed the orientation of surface methyl groups from ˜47° to ˜40°. After a dielectric recovery process that followed the RIE treatment, the surface molecular structure was dominated by methyl groups with an orientation of ˜55° and the methyl surface coverage at the repaired surface was 271% relative to the pristine surface. Auger depth profiling indicated that the RIE treatment altered the top ˜25 nm of the film and that the dielectric recovery treatment repaired the top ˜9 nm of the film. Both SFG and Auger profiling results indicated that the buried SiCNH/pSiCOH interface was not affected by the RIE or the dielectric recovery process. Beyond characterizing low-k materials, the developed methodology is general and can be used to distinguish and characterize different molecular structures and elemental compositions at the surface, in the bulk, and at the buried interface of many different polymer or organic thin films.
Automated drug dispensing system reduces medication errors in an intensive care setting.
Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick
2010-12-01
We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; p<.05); however, no significant difference was observed before automated dispensing system implementation (20.4% and 19.3%, respectively; not significant). Before-and-after comparisons in the study unit also showed a significantly reduced percentage of total opportunities for error (20.4% and 13.5%; p<.01). An analysis of detailed opportunities for error showed a significant impact of the automated dispensing system in reducing preparation errors (p<.05). Most errors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.
MaRIE: A facility for time-dependent materials science at the mesoscale
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris William; Kippen, Karen Elizabeth
To meet new and emerging national security issues the Laboratory is stepping up to meet another grand challenge—transitioning from observing to controlling a material’s performance. This challenge requires the best of experiment, modeling, simulation, and computational tools. MaRIE is the Laboratory’s proposed flagship experimental facility intended to meet the challenge.
ERIC Educational Resources Information Center
Gateley, D. E.
2015-01-01
The UK government's austerity cuts have negatively impacted many voluntary-sector interventions that provided support to refugees. One such intervention, the Refugee Integration and Employment Service (RIES), is discussed in this paper. The RIES was a UK Border Agency-funded integration programme for recognised refugees and operated through…
ERIC Educational Resources Information Center
Natoli, Riccardo; Zuhair, Segu
2013-01-01
The resource-infrastructure-environment (RIE) index was proposed as an alternative measure of progress which was then employed to: (1) compare the aggregate (single summary) index findings between Australia (mid-industrialised nation), Mexico (emerging economy), and the US (highly industrialised nation); and (2) compare the RIE index against the…
Graphene nanoribbons: Relevance of etching process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simonet, P., E-mail: psimonet@phys.ethz.ch; Bischoff, D.; Moser, A.
2015-05-14
Most graphene nanoribbons in the experimental literature are patterned using plasma etching. Various etching processes induce different types of defects and do not necessarily result in the same electronic and structural ribbon properties. This study focuses on two frequently used etching techniques, namely, O{sub 2} plasma ashing and O{sub 2 }+ Ar reactive ion etching (RIE). O{sub 2} plasma ashing represents an alternative to RIE physical etching for sensitive substrates, as it is a more gentle chemical process. We find that plasma ashing creates defective graphene in the exposed trenches, resulting in instabilities in the ribbon transport. These are probably caused bymore » more or larger localized states at the edges of the ashed device compared to the RIE defined device.« less
NASA Astrophysics Data System (ADS)
Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin
2018-04-01
We present an analysis for measurement-device-independent quantum key distribution with correlated source-light-intensity errors. Numerical results show that the results here can greatly improve the key rate especially with large intensity fluctuations and channel attenuation compared with prior results if the intensity fluctuations of different sources are correlated.
An educational and audit tool to reduce prescribing error in intensive care.
Thomas, A N; Boxall, E M; Laha, S K; Day, A J; Grundy, D
2008-10-01
To reduce prescribing errors in an intensive care unit by providing prescriber education in tutorials, ward-based teaching and feedback in 3-monthly cycles with each new group of trainee medical staff. Prescribing audits were conducted three times in each 3-month cycle, once pretraining, once post-training and a final audit after 6 weeks. The audit information was fed back to prescribers with their correct prescribing rates, rates for individual error types and total error rates together with anonymised information about other prescribers' error rates. The percentage of prescriptions with errors decreased over each 3-month cycle (pretraining 25%, 19%, (one missing data point), post-training 23%, 6%, 11%, final audit 7%, 3%, 5% (p<0.0005)). The total number of prescriptions and error rates varied widely between trainees (data collection one; cycle two: range of prescriptions written: 1-61, median 18; error rate: 0-100%; median: 15%). Prescriber education and feedback reduce manual prescribing errors in intensive care.
Islamic Resurgence in Algeria: The Rise of the Islamic Salvation Front
1993-05-01
Julien, Histolre de l’Afrique du Nord: Tunisie-Alg~rie- Maroc de la conqufte arabe A 1830, 2 ed., Roger LeTourneau ed., Paris, Payot, 1956. 4Jamil M...Nord. Tunisie-Alg~rie- Maroc de la conqu~te arabe A 1830. 2 ed. Roger LeTourneau, ed., Paris, Payot, 1956. El-Kenz, Ali. Algerian Reflections on Arab
ERIC Educational Resources Information Center
Wallat, Cynthia, Comp.
This selective bibliography cites references pertaining to early childhood education from "Research in Education" (RIE) and "Current Index to Journals in Education" (CIJE). The bibliography is divided into three sections. The first two sections contain references from RIE and CIJE from spring 1967 through spring 1973; the last section updates the…
An Overview of the MaRIE X-FEL and Electron Radiography LINAC RF Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley, Joseph Thomas III; Rees, Daniel Earl; Scheinker, Alexander
The purpose of the Matter-Radiation Interactions in Extremes (MaRIE) facility at Los Alamos National Laboratory is to investigate the performance limits of materials in extreme environments. The MaRIE facility will utilize a 12 GeV linac to drive an X-ray Free-Electron Laser (FEL). Most of the same linac will also be used to perform electron radiography. The main linac is driven by two shorter linacs; one short linac optimized for X-FEL pulses and one for electron radiography. The RF systems have historically been the one of the largest single component costs of a linac. We will describe the details of themore » different types of RF systems required by each part of the linacs. Starting with the High Power RF system, we will present our methodology for the choice of RF system peak power and pulselength with respect to klystron parameters, modulator parameters, performance requirements and relative costs. We will also present an overview of the Low Level RF systems that are proposed for MaRIE and briefly describe their use with some proposed control schemes.« less
NASA Astrophysics Data System (ADS)
Muttalib, M. Firdaus A.; Chen, Ruiqi Y.; Pearce, S. J.; Charlton, Martin D. B.
2017-11-01
In this paper, we demonstrate the optimization of reactive-ion etching (RIE) parameters for the fabrication of tantalum pentoxide (Ta2O5) waveguide with chromium (Cr) hard mask in a commercial OIPT Plasmalab 80 RIE etcher. A design of experiment (DOE) using Taguchi method was implemented to find optimum RF power, mixture of CHF3 and Ar gas ratio, and chamber pressure for a high etch rate, good selectivity, and smooth waveguide sidewall. It was found that the optimized etch condition obtained in this work were RF power = 200 W, gas ratio = 80 %, and chamber pressure = 30 mTorr with an etch rate of 21.6 nm/min, Ta2O5/Cr selectivity ratio of 28, and smooth waveguide sidewall.
Experimental Physical Sciences Vistas: MaRIE (draft)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shlachter, Jack
To achieve breakthrough scientific discoveries in the 21st century, a convergence and integration of world-leading experimental facilities and capabilities with theory, modeling, and simulation is necessary. In this issue of Experimental Physical Sciences Vistas, I am excited to present our plans for Los Alamos National Laboratory's future flagship experimental facility, MaRIE (Matter-Radiation Interactions in Extremes). MaRIE is a facility that will provide transformational understanding of matter in extreme conditions required to reduce or resolve key weapons performance uncertainties, develop the materials needed for advanced energy systems, and transform our ability to create materials by design. Our unique role in materialsmore » science starting with the Manhattan Project has positioned us well to develop a contemporary materials strategy pushing the frontiers of controlled functionality - the design and tailoring of a material for the unique demands of a specific application. Controlled functionality requires improvement in understanding of the structure and properties of materials in order to synthesize and process materials with unique characteristics. In the nuclear weapons program today, improving data and models to increase confidence in the stockpile can take years from concept to new knowledge. Our goal with MaRIE is to accelerate this process by enhancing predictive capability - the ability to compute a priori the observables of an experiment or test and pertinent confidence intervals using verified and validated simulation tools. It is a science-based approach that includes the use of advanced experimental tools, theoretical models, and multi-physics codes, simultaneously dealing with multiple aspects of physical operation of a system that are needed to develop an increasingly mature predictive capability. This same approach is needed to accelerate improvements to other systems such as nuclear reactors. MaRIE will be valuable to many national security science challenges. Our first issue of Vistas focused on our current national user facilities (the Los Alamos Neutron Science Center [LANSCE], the National High Magnetic Field Laboratory-Pulsed Field Facility, and the Center for Integrated Nanotechnologies) and the vitality they bring to our Laboratory. These facilities are a magnet for students, postdoctoral researchers, and staff members from all over the world. This, in turn, allows us to continue to develop and maintain our strong staff across the relevant disciplines and conduct world-class discovery science. The second issue of Vistas was devoted entirely to the Laboratory's materials strategy - one of the three strategic science thrusts for the Laboratory. This strategy has helped focus our thinking for MaRIE. We believe there is a bright future in cutting-edge experimental materials research, and that a 21st-century facility with unique capability is necessary to fulfill this goal. The Laboratory has spent the last several years defining MaRIE, and this issue of Vistas presents our current vision of that facility. MaRIE will leverage LANSCE and our other user facilities, as well as our internal and external materials community for decades to come, giving Los Alamos a unique competitive advantage, advancing materials science for the Laboratory's missions and attracting and recruiting scientists of international stature. MaRIE will give the international materials research community a suite of tools capable of meeting a broad range of outstanding grand challenges.« less
Novaes, Maria Rita Carvalho Garbi; Novaes, Luiz Carlos Garcez; Guilhem, Dirce; Lolas, Fernando; Silveira, Carla; Guiotti, Murilo
2009-01-01
Objetivo Realizar uma análise da inserção da ética e humanidades no currículo do Curso de Medicina da Escola Superior em Ciências da Saúde - ESCS, escola pública do Distrito Federal, Brasil, de forma a contribuir com o processo de gestão curricular. Metodologia O Estudo é de coorte e documental. Foram pesquisados 37 termos relacionados à ética e 36 referentes à humanização nos objetivos educacionais e conteúdo dos módulos temáticos, habilidades e atitudes e interação ensino-serviço-comunidade, de 1a a 4a série e no programa do internato no currículo (ano 2006) e no projeto pedagógico do Curso de Medicina (2001). Resultados Maior inserção da humanização, ética e bioética na 1a e 2a série, quando comparado à inserção na 3a e 4a série e no internato, (IC95%-α=0,034, pvalue=0,007). Unidade de habilidades e atitudes: freqüência das 3 temáticas no currículo da 1a a 4a séries (IC95%-α=0,026, pvalue=0,013). Quando comparada a inserção entre o internato e as quatro primeiras séries, observa-se que nestas a inserção da temática humanização é superior (IC95%-α=0,042, pvalue=0,029). Conclusão O currículo desenvolvido no ano de 2006 na ESCS apresentou correlação com o projeto pedagógico do curso e contemplou a temática de forma abrangente, em todas as séries e internato. PMID:20396594
Kipp, Aaron M.; Audet, Carolyn M.; Earnshaw, Valerie A.; Owens, Jared; McGowan, Catherine C.; Wallston, Kenneth A.
2015-01-01
There is little consensus about which of the many validated human immunodeficiency virus (HIV) stigma scales should be regularly used, with few being re-validated in different contexts or evaluated for how they compare to other, existing HIV stigma scales. The purpose of this exploratory study was to re-validate the Van Rie HIV/AIDS-Related Stigma Scale, originally validated in Thailand and using a third-person wording structure, for use with people living with HIV in the United States. Adult HIV clinic patients completed a survey including the Berger and Van Rie scales, and measures of social support and depression. Eighty-five of 211 (40%) eligible participants provided data for both stigma scales. Exploratory factor analyses identified three factors to the Van Rie scale: Loss of Social Relationships (new subscale), Managing HIV Concealment (new subscale), and Perceived Community Stigma (original subscale). These subscales were moderately inter-related (r = 0.51 to 0.58) with acceptable to excellent reliability (Cronbach’s alpha = 0.69 to 0.90). The Van Rie subscales were also moderately inter-correlated with the Berger subscales (r = 0.44 to 0.76), had similar construct validity, and tended to have higher mean stigma scores when compared with Berger subscales that were conceptually most similar. The revised Van Rie HIV-related Stigma Scale demonstrates good validity and internal consistency, offering a valid measure of HIV stigma with a three-factor structure. The third-person wording may be particularly suitable for measuring stigmatizing attitudes during an individual’s transition from at-risk and undergoing HIV testing to newly diagnosed, a time when experiences of discrimination and processing issues of disclosure have not yet occurred. The stigma mechanisms for individuals making this transition have not been well explored. These scenarios, combined with the observed non-response to the Berger Enacted Stigma subscale items (a surprise finding), highlight gaps in our understanding of HIV stigma and how best to measure it. PMID:25738884
Šupak-Smolčić, Vesna; Šimundić, Ana-Maria
2013-01-01
In February 2013, Biochemia Medica has joined CrossRef, which enabled us to implement CrossCheck plagiarism detection service. Therefore, all manuscript submitted to Biochemia Medica are now first assigned to Research integrity editor (RIE), before sending the manuscript for peer-review. RIE submits the text to CrossCheck analysis and is responsible for reviewing the results of the text similarity analysis. Based on the CrossCheck analysis results, RIE subsequently provides a recommendation to the Editor-in-chief (EIC) on whether the manuscript should be forwarded to peer-review, corrected for suspected parts prior to peer-review or immediately rejected. Final decision on the manuscript is, however, with the EIC. We hope that our new policy and manuscript processing algorithm will help us to further increase the overall quality of our Journal. PMID:23894858
NASA Astrophysics Data System (ADS)
Kamath, K. K.; Vaya, P. R.
1992-12-01
A c irclAl: L mode 1 for Laser diodes based ort nu I C z. mode ra t e eqtiat tons i. s presert t ed hre. be I ay 1 i ries are cornec t ed aL the outpt nodes iduch provide de Lays corresponding to reLative propaation de 1 ays D7i for L aser Lorii LILdZ. ia I modes L!. . ) . n w optical fiber. Th(s modeL s(iruLat. d lASCfl3 th* c(reut s(nwLa LLOTt pacha6e SPICE2. The results were compared with those resuLts by the dtrect rtv soLution of th muLti mode rate equations.
ERIC Educational Resources Information Center
Niepel, Christoph; Brunner, Martin; Preckel, Franzis
2014-01-01
Students' cognitive and motivational profiles have a large impact on their academic careers. The development of such profiles can partly be explained by the reciprocal internal/external frame of reference model (RI/E model). The RI/E model predicts positive and negative longitudinal effects between academic self-concepts and achievements within…
Fabrication of wafer-scale nanopatterned sapphire substrate through phase separation lithography
NASA Astrophysics Data System (ADS)
Guo, Xu; Ni, Mengyang; Zhuang, Zhe; Dai, Jiangping; Wu, Feixiang; Cui, Yushuang; Yuan, Changsheng; Ge, Haixiong; Chen, Yanfeng
2016-04-01
A phase separation lithography (PSL) based on polymer blend provides an extremely simple, low-cost, and high-throughput way to fabricate wafer-scale disordered nanopatterns. This method was introduced to fabricate nanopatterned sapphire substrates (NPSSs) for GaN-based light-emitting diodes (LEDs). The PSL process only involved in spin-coating of polystyrene (PS)/polyethylene glycol (PEG) polymer blend on sapphire substrate and followed by a development with deionized water to remove PEG moiety. The PS nanoporous network was facilely obtained, and the structural parameters could be effectively tuned by controlling the PS/PEG weight ratio of the spin-coating solution. 2-in. wafer-scale NPSSs were conveniently achieved through the PS nanoporous network in combination with traditional nanofabrication methods, such as O2 reactive ion etching (RIE), e-beam evaporation deposition, liftoff, and chlorine-based RIE. In order to investigate the performance of such NPSSs, typical blue LEDs with emission wavelengths of ~450 nm were grown on the NPSS and a flat sapphire substrate (FSS) by metal-organic chemical vapor deposition, respectively. The integral photoluminescence (PL) intensity of the NPSS LED was enhanced by 32.3 % compared to that of the FSS-LED. The low relative standard deviation of 4.7 % for PL mappings of NPSS LED indicated the high uniformity of PL data across the whole 2-in. wafer. Extremely simple, low cost, and high throughput of the process and the ability to fabricate at the wafer scale make PSL a potential method for production of nanopatterned sapphire substrates.
Error correcting coding-theory for structured light illumination systems
NASA Astrophysics Data System (ADS)
Porras-Aguilar, Rosario; Falaggis, Konstantinos; Ramos-Garcia, Ruben
2017-06-01
Intensity discrete structured light illumination systems project a series of projection patterns for the estimation of the absolute fringe order using only the temporal grey-level sequence at each pixel. This work proposes the use of error-correcting codes for pixel-wise correction of measurement errors. The use of an error correcting code is advantageous in many ways: it allows reducing the effect of random intensity noise, it corrects outliners near the border of the fringe commonly present when using intensity discrete patterns, and it provides a robustness in case of severe measurement errors (even for burst errors where whole frames are lost). The latter aspect is particular interesting in environments with varying ambient light as well as in critical safety applications as e.g. monitoring of deformations of components in nuclear power plants, where a high reliability is ensured even in case of short measurement disruptions. A special form of burst errors is the so-called salt and pepper noise, which can largely be removed with error correcting codes using only the information of a given pixel. The performance of this technique is evaluated using both simulations and experiments.
Chao, E.C.T.
1976-01-01
Recently discovered mineral-produced, deeply incised striae and mirror-like polish on broken surfaces of limestone fragments from the sedimentary ejecta of the Ries impact crater of southern Germany are described. The striae and polish were produced under high confining pressures during high-velocity nonballistic transport of the ejecta mass within the time span of the cratering event (measured in terms of seconds). The striae on these fragments were produced by scouring by small mineral grains embedded in the surrounding clay matrix, and the polish was formed under the same condition, by movements of relatively fragment-free clay against the fragment surfaces. The occurrence of these striae and polish is key evidence for estimating the distribution and determining the relative importance of nonballistic and ballistic transport of ejecta from the shallow Ries stony meteorite impact crater.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris William
Los Alamos National Laboratory’s proposed MaRIE facility is slated to introduce the world’s highest energy hard x-ray free electron laser (XFEL). As the light source for the Matter-Radiation Interactions in Extremes experimental facility (MaRIE), the 42-keV XFEL, with bursts of x-ray pulses at gigahertz repetition for studying fast dynamical processes, will help accelerate discovery and design of the advanced materials needed to meet 21st-century national security and energy security challenges. Yet the science of free-electron lasers has a long and distinguished history at Los Alamos National Laboratory (LANL), where for nearly four decades Los Alamos scientists have been performing research,more » design, development, and collaboration work in FEL science. The work at Los Alamos has evolved from low-gain amplifier and oscillator FEL development to highbrightness photoinjector development, and later, self-amplified spontaneous emission (SASE) and high-gain amplifier FEL development.« less
Carbonate-silicate liquid immiscibility upon impact melting, Ries Crater, Germany
NASA Astrophysics Data System (ADS)
Graup, Guenther
1999-05-01
The 24-km-diameter Ries impact crater in southern Germany is one of the most studied impact structures on Earth. The Ries impactor struck a Triassic to Upper Jurassic sedimentary sequence overlying Hercynian crystalline basement. At the time of impact (14.87 +/- 0.36 Ma; Storzer et al., 1995), the 350 m thick Malm limestone was present only to the S and E of the impact site. To the N and W, the Malm had been eroded away, exposing the underlying Dogger and Lias. The largest proportion of shocked target material is in the impact melt-bearing breccia suevite. The suevite had been believed to be derived entirely from the crystalline basement. Calcite in the suevite has been interpreted as a post-impact hydrothermal deposit. From optical inspection of 540 thin sections of suevite from 32 sites, I find that calcite in the suevite shows textural evidence of liquid immiscibility with the silicate impact melt. Textural evidence of liquid immiscibility between silicate and carbonate melt in the Ries suevite includes: carbonate globules within silicate glass, silicate globules embedded in carbonate, deformable and coalescing carbonate spheres within silicate glass, sharp menisci or cusps and budding between silicate and carbonate melt, fluidal textures and gas vesicles in carbonate schlieren, a quench crystallization sequence of the carbonate, spinifex textured quenched carbonate, separate carbonate spherules in the suevite mineral-fragment-matrix, and inclusions of mineral fragments suspended in carbonate blebs. Given this evidence of liquid immiscibility, the carbonate in the suevite has, therefore, like the silicate melt a primary origin by impact shock melting. Evidence of carbonate-silicate liquid immiscibility is abundant in the suevites to the SW to E of the Ries crater. The rarer suevites to the W to NE of the crater are nearly devoid of carbonate melts. This correspondence between the occurrence of outcropping limestones at the target surface and the formation of carbonate melt, indicates that the Malm limestones are the source rocks of the carbonate impact melt. This correspondence shows that the suevites preserve a compositional memory of their source rocks. From the regional distribution of suevites with or without immiscible carbonate melts, it is inferred that the Ries impactor hit the steep Albtrauf escarpment at its toe, in an oblique impact from the north.
A Reactive-Ion Etch for Patterning Piezoelectric Thin Film
NASA Technical Reports Server (NTRS)
Yang, Eui-Hyeok; Wild, Larry
2003-01-01
Reactive-ion etching (RIE) under conditions described below has been found to be a suitable means for patterning piezoelectric thin films made from such materials as PbZr(1-x)Ti(x)O3 or Ba(x)Sr(1.x)TiO3. In the original application for which this particular RIE process was developed, PbZr(1-x)Ti(x)O3 films 0.5 microns thick are to be sandwiched between Pt electrode layers 0.1 microns thick and Ir electrode layers 0.1 microns thick to form piezoelectric capacitor structures. Such structures are typical of piezoelectric actuators in advanced microelectromechanical systems now under development or planned to be developed in the near future. RIE of PbZr(1-x)Ti(x)O3 is usually considered to involve two major subprocesses: an ion-assisted- etching reaction, and a sputtering subprocess that removes reactive byproducts. RIE is favored over other etching techniques because it offers a potential for a high degree of anisotropy, high-resolution pattern definition, and good process control. However, conventional RIE is not ideal for patterning PbZr(1-x)Ti(x)O3 films at a thickness as great as that in the original intended application. In order to realize the potential benefits mentioned above, it is necessary to optimize process conditions . in particular, the composition of the etching gas and the values of such other process parameters as radio-frequency power, gas pressure, gas-flow rate, and duration of the process. Guidelines for determining optimum conditions can be obtained from experimental determination of etch rates as functions of these parameters. Etch-gas mixtures of BCl3 and Cl2, some also including Ar, have been found to offer a high degree of selectivity as needed for patterning of PbZr(1-x)Ti(x)O3 films on top of Ir electrode layers in thin-film capacitor structures. The selectivity is characterized by a ratio of approx.10:1 (rate of etching PbZr(1-x)Ti(x)O3 divided by rate of etching Ir and IrO(x)). At the time of reporting the information for this article, several experiments on RIE in BCl3 and Cl2 (and sometimes Ar) had demonstrated the 10:1 selectivity ratio, and further experiments to enhance understanding and obtain further guidance for optimizing process conditions were planned.
Distributed biotin–streptavidin transcription roadblocks for mapping cotranscriptional RNA folding
Strobel, Eric J.; Nedialkov, Yuri; Artsimovitch, Irina
2017-01-01
Abstract RNA folding during transcription directs an order of folding that can determine RNA structure and function. However, the experimental study of cotranscriptional RNA folding has been limited by the lack of easily approachable methods that can interrogate nascent RNA structure at nucleotide resolution. To address this, we previously developed cotranscriptional selective 2΄-hydroxyl acylation analyzed by primer extension sequencing (SHAPE-Seq) to simultaneously probe all intermediate RNA transcripts during transcription by stalling elongation complexes at catalytically dead EcoRIE111Q roadblocks. While effective, the distribution of elongation complexes using EcoRIE111Q requires laborious PCR using many different oligonucleotides for each sequence analyzed. Here, we improve the broad applicability of cotranscriptional SHAPE-Seq by developing a sequence-independent biotin–streptavidin (SAv) roadblocking strategy that simplifies the preparation of roadblocking DNA templates. We first determine the properties of biotin–SAv roadblocks. We then show that randomly distributed biotin–SAv roadblocks can be used in cotranscriptional SHAPE-Seq experiments to identify the same RNA structural transitions related to a riboswitch decision-making process that we previously identified using EcoRIE111Q. Lastly, we find that EcoRIE111Q maps nascent RNA structure to specific transcript lengths more precisely than biotin–SAv and propose guidelines to leverage the complementary strengths of each transcription roadblock in cotranscriptional SHAPE-Seq. PMID:28398514
Distributed biotin-streptavidin transcription roadblocks for mapping cotranscriptional RNA folding.
Strobel, Eric J; Watters, Kyle E; Nedialkov, Yuri; Artsimovitch, Irina; Lucks, Julius B
2017-07-07
RNA folding during transcription directs an order of folding that can determine RNA structure and function. However, the experimental study of cotranscriptional RNA folding has been limited by the lack of easily approachable methods that can interrogate nascent RNA structure at nucleotide resolution. To address this, we previously developed cotranscriptional selective 2΄-hydroxyl acylation analyzed by primer extension sequencing (SHAPE-Seq) to simultaneously probe all intermediate RNA transcripts during transcription by stalling elongation complexes at catalytically dead EcoRIE111Q roadblocks. While effective, the distribution of elongation complexes using EcoRIE111Q requires laborious PCR using many different oligonucleotides for each sequence analyzed. Here, we improve the broad applicability of cotranscriptional SHAPE-Seq by developing a sequence-independent biotin-streptavidin (SAv) roadblocking strategy that simplifies the preparation of roadblocking DNA templates. We first determine the properties of biotin-SAv roadblocks. We then show that randomly distributed biotin-SAv roadblocks can be used in cotranscriptional SHAPE-Seq experiments to identify the same RNA structural transitions related to a riboswitch decision-making process that we previously identified using EcoRIE111Q. Lastly, we find that EcoRIE111Q maps nascent RNA structure to specific transcript lengths more precisely than biotin-SAv and propose guidelines to leverage the complementary strengths of each transcription roadblock in cotranscriptional SHAPE-Seq. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
NASA Astrophysics Data System (ADS)
Mader, Dieter; Montanari, Alessandro; Gattacceca, Jérôme; Koeberl, Christian; Handler, Robert; Coccioni, Rodolfo
2001-12-01
A nearly complete and undisturbed Miocene carbonate sequence is present in the easternmost part of the Umbria-Marche basin, Italy, which is ideal for detailed and integrated stratigraphic investigations of the Miocene Epoch. In this study, we were trying to obtain evidence for the presence or absence of distal ejecta from the 15 Ma Ries impact structure in southern Germany, located about 600 km to the north-northwest of the Umbria-Marche basin. The first step is to find coeval strata in the Umbria-Marche sequence. At the La Vedova section, Cònero Riviera, we dated a volcaniclastic biotite-rich clay layer, the Aldo Level, which is situated within planktonic foraminiferal Zone N8, at 14.9±0.2 Ma, using the 40Ar/39Ar method. Together with detailed geologic and stratigraphic information about the Aldo Level, the resulting age can be used confidentially to calibrate the Langhian stage. Besides providing new constraints on Miocene geochronology, this age can now be used for impact stratigraphic studies. To directly correlate the biotite ages of the La Vedova section with rocks from the Ries impact event, Ries impact glass was also analyzed and found to be coeval. Although unrelated to this impact event, the biotite-rich clay layer should help in the search for evidence of distal ejecta related to the Ries crater.
Polymer microfilters with nanostructured surfaces for the culture of circulating cancer cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarova, Olga V.; Adams, Daniel L.; Divan, Ralu
There is a critical need to improve the accuracy of drug screening and testing through the development of in vitro culture systems that more effectively mimic the in vivo environment. Surface topographical features on the nanoscale level, in short nanotopography, effect the cell growth patterns, and hence affect cell function in culture. We report the preliminary results on the fabrication, and subsequent cellular growth, of nanoscale surface topography on polymer microfilters using cell lines as a precursor to circulating tumor cells (CTCs). To create various nanoscale features on the microfilter surface, we used reactive ion etching (RIE) with and withoutmore » an etching mask. An anodized aluminum oxide (AAO) membrane fabricated directly on the polymer surface served as an etching mask. Polymer filters with a variety of modified surfaces were used to compare the effects on the culture of cancer cell lines in blank culture wells, with untreated microfilters or with RIE-treated microfilters. We then report the differences of cell shape, phenotype and growth patterns of bladder and glioblastoma cancer cell lines after isolation on the various types of material modifications. Our data suggest that RIE modified polymer filters can isolate model cell lines while retaining ell viability, and that the RIE filter modification allows T24 monolayering cells to proliferate as a structured cluster. Copyright 2016 The Authors. Published by Elsevier B.V. All rights reserved.« less
ERIC Educational Resources Information Center
Alhaisoni, Eid M.; Al-Zuoud, Khalid M.; Gaudel, Daya Ram
2015-01-01
This study reports the types of spelling errors made by the beginner learners of English in the EFL context as well as the major sources underpinning such errors in contextual writing composition tasks. Data were collected from written samples of 122 EFL students (male and female) enrolled in the intensive English language programme during the…
NASA Astrophysics Data System (ADS)
Proost, Joris; Maex, Karen; Delacy, Luc
2000-01-01
We have discussed electromigration (EM)-induced drift in polycrystalline damascene versus reactive ion etched (RIE) Al(Cu) in part I. For polycrystalline Al(Cu), mass transport is well documented to occur through sequential stages : an incubation period (attributed to Cu depletion beyond a critical length) followed by the Al drift stage. In this work, the drift behavior of bamboo RIE and damascene Al(Cu) is analyzed. Using Blech-type test structures, mass transport in RIE lines was shown to proceed both by lattice and interfacial diffusion. The dominating mechanism depends on the Cu distribution in the line, as was evidenced by comparing as-patterned (lattice EM) and RTP-annealed (interface EM) samples. The interfacial EM only occurs at metallic interfaces. In that case, Cu alloying was observed to retard Al interfacial mass transport, giving rise to an incubation time. Although the activation energy for the incubation time was found similar to the one controlling Al lattice drift, for which no incubation time was observed, lattice EM is preferred over interfacial EM because it is insensitive to enhancing geometrical effects upon scaling. When comparing interfacial electromigration in RIE with bamboo damascene Al(Cu), with the incubation time rate controlling for both, the higher EM threshold observed for damascene was shown to be insufficient to compensate for its significantly increased Cu depletion rate, contrary to the case of polycrystalline Al(Cu) interconnects. Two factors were demonstrated to contribute. First, there are more metallic interfaces, intrinsically related to the use of wetting or barrier layers in recessed features. Second, specific to this study, the additional formation of TiAl3 at the trench sidewalls further enhanced the Cu depletion rate, and reduced the rate-controlling incubation time. A separate drift study on RIE via-type test structures indicated that it is very difficult to suppress interfacial mass transport in favor of lattice EM upon TiAl3 formation.
Lait humain provenant d’une banque de dons ou acheté en ligne?
St-Onge, Maude; Chaudhry, Shahnaz; Koren, Gideon
2015-01-01
Résumé Question Une de mes patientes m’a demandé si elle pourrait se procurer du lait humain par Internet pour allaiter son nourrisson s’il le fallait. L’usage de lait humain provenant d’une banque de dons est-il plus sécuritaire que son achat en ligne? Réponse L’Organisation mondiale de la Santé et l’American Academy of Pediatrics recommandent d’utiliser des dons de lait humain comme choix à privilégier lorsque le lait maternel n’est pas disponible. Cependant, la Société canadienne de pédiatrie n’approuve pas le partage de lait humain non traité. Le lait humain entreposé dans les banques de lait diffère de celui qu’on peut se procurer par Internet en raison du processus rigoureux de sélection des donneuses, des fréquentes inspections de la qualité, des procédés de transport règlementés et du processus de pasteurisation conforme aux directives établies par l’Agence canadienne d’inspection des aliments. La plupart des échantillons achetés en ligne contiennent des bactéries à gram négatif ou comptent au total plus de 104 unités formant colonies de bactéries aérobiques par millilitre; ils renferment aussi en moyenne au décompte total plus de bactéries aérobiques, de bactéries à gram négatif, de coliformes et de Staphylococcus spp que les échantillons des banques de lait. La croissance de la plupart des espèces de bactéries est associée au nombre de jours en transit, ce qui porte à croire que les conditions de collecte, d’entreposage et de transport sont médiocres pour le lait acheté en ligne.
A multifaceted program for improving quality of care in intensive care units: IATROREF study.
Garrouste-Orgeas, Maite; Soufir, Lilia; Tabah, Alexis; Schwebel, Carole; Vesin, Aurelien; Adrie, Christophe; Thuong, Marie; Timsit, Jean Francois
2012-02-01
To test the effects of three multifaceted safety programs designed to decrease insulin administration errors, anticoagulant prescription and administration errors, and errors leading to accidental removal of endotracheal tubes and central venous catheters, respectively. Medical errors and adverse events are associated with increased mortality in intensive care patients, indicating an urgent need for prevention programs. Multicenter cluster-randomized study. One medical intensive care unit in a university hospital and two medical-surgical intensive care units in community hospitals belonging to the Outcomerea Study Group. Consecutive patients >18 yrs admitted from January 2007 to January 2008 to the intensive care units. We tested three multifaceted safety programs vs. standard care in random order, each over 2.5 months, after a 1.5-month observation period. Incidence rates of medical errors/1000 patient-days in the multifaceted safety program and standard-care groups were compared using adjusted hierarchical models. In 2117 patients with 15,014 patient-days, 8520 medical errors (567.5/1000 patient-days) were reported, including 1438 adverse events (16.9%, 95.8/1000 patient-days). The insulin multifaceted safety program significantly decreased errors during implementation (risk ratio 0.65; 95% confidence interval [CI] 0.52-0.82; p = .0003) and after implementation (risk ratio 0.51; 95% CI 0.35-0.73; p = .0004). A significant Hawthorne effect was found. The accidental tube/catheter removal multifaceted safety program decreased errors significantly during implementation (odds ratio [OR] 0.34; 95% CI 0.15-0.81; p = .01]) and nonsignificantly after implementation (OR 1.65; 95% CI 0.78-3.48). The anticoagulation multifaceted safety program was not significantly effective (OR 0.64; 95% CI 0.26-1.59) but produced a significant Hawthorne effect. A multifaceted program was effective in preventing insulin errors and accidental tube/catheter removal. Significant Hawthorne effects occurred, emphasizing the need for appropriately designed studies before definitively implementing strategies. clinicaltrials.gov Identifier: NCT00461461.
WIS Implementation Study Report. Volume 1. Main Report.
1983-10-01
Luenberger, Prof. David G. * Stanford University Ries, Dr. Daniel R. * Computer Corporation of America Schill, John Naval Ocean Systems Center Shrier , Dr...Robert E. 43 Kaczmarek, Dr. Thomas S. 45 Klein, Dr. Stanely A. 47 Kramer, Dr. John F. 49 Larsen, Dr. Robert E. 55 Luenberger, Prof. David G. 58...Riddle, Dr. William E. 76 Ries, Dr. Daniel R. 82 Sapp, Mr. John W. 88 Shelley, Mr. Stephen H. 89 Shrier , Dr. Stefan 94 Slusarczuk, Dr. Marko M.G. 96
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris William
At the request of Katherine Richardson-McDaniel, Staff Member to U.S. Senator Martin Heinrich (D-NM), a high-level briefing was requested about MaRIE 1.0, the Matter-Radiation Interactions in Extremes effort at Los Alamos National Laboratory. What it would be, the mission need motivation, the scientific challenge, and the current favorable impact on both programs and people are shown in viewgraph form.
A description of medication errors reported by pharmacists in a neonatal intensive care unit.
Pawluk, Shane; Jaam, Myriam; Hazi, Fatima; Al Hail, Moza Sulaiman; El Kassem, Wessam; Khalifa, Hanan; Thomas, Binny; Abdul Rouf, Pallivalappila
2017-02-01
Background Patients in the Neonatal Intensive Care Unit (NICU) are at an increased risk for medication errors. Objective The objective of this study is to describe the nature and setting of medication errors occurring in patients admitted to an NICU in Qatar based on a standard electronic system reported by pharmacists. Setting Neonatal intensive care unit, Doha, Qatar. Method This was a retrospective cross-sectional study on medication errors reported electronically by pharmacists in the NICU between January 1, 2014 and April 30, 2015. Main outcome measure Data collected included patient information, and incident details including error category, medications involved, and follow-up completed. Results A total of 201 NICU pharmacists-reported medication errors were submitted during the study period. All reported errors did not reach the patient and did not cause harm. Of the errors reported, 98.5% occurred in the prescribing phase of the medication process with 58.7% being due to calculation errors. Overall, 53 different medications were documented in error reports with the anti-infective agents being the most frequently cited. The majority of incidents indicated that the primary prescriber was contacted and the error was resolved before reaching the next phase of the medication process. Conclusion Medication errors reported by pharmacists occur most frequently in the prescribing phase of the medication process. Our data suggest that error reporting systems need to be specific to the population involved. Special attention should be paid to frequently used medications in the NICU as these were responsible for the greatest numbers of medication errors.
Error analysis and correction in wavefront reconstruction from the transport-of-intensity equation
Barbero, Sergio; Thibos, Larry N.
2007-01-01
Wavefront reconstruction from the transport-of-intensity equation (TIE) is a well-posed inverse problem given smooth signals and appropriate boundary conditions. However, in practice experimental errors lead to an ill-condition problem. A quantitative analysis of the effects of experimental errors is presented in simulations and experimental tests. The relative importance of numerical, misalignment, quantization, and photodetection errors are shown. It is proved that reduction of photodetection noise by wavelet filtering significantly improves the accuracy of wavefront reconstruction from simulated and experimental data. PMID:20052302
Role of microstructure and doping on the mechanical strength and toughness of polysilicon thin films
Yagnamurthy, Sivakumar; Boyce, Brad L.; Chasiotis, Ioannis
2015-03-24
We investigated the role of microstructure and doping on the mechanical strength of microscale tension specimens of columnar grain and laminated polysilicon doped with different concentrations of phosphorus. The average tensile strengths of undoped columnar and laminated polysilicon specimens were 1.3 ± 0.1 and 2.45 ± 0.3 GPa, respectively. Heavy doping reduced the strength of columnar polysilicon specimens to 0.9 ± 0.1 GPa. On grounds of Weibull statistics, the experimental results from specimens with gauge sections of 1000 μm × 100 μm × 1 μm predicted quite well the tensile strength of specimens with gauge sections of 150 μm ×more » 3.75 μm × 1 μm, and vice versa. The large difference in the mechanical strength between columnar and laminated polysilicon specimens was due to sidewall flaws in columnar polysilicon, which were introduced during reactive ion etching (RIE) and were further exacerbated by phosphorus doping. Moreover, the removal of the large defect regions at the sidewalls of columnar polysilicon specimens via ion milling increased their tensile strength by 70%-100%, approaching the strength of laminated polysilicon, which implies that the two types of polysilicon films have comparable tensile strength. Measurements of the effective mode I critical stress intensity factor, KIC,eff, also showed that all types of polysilicon films had comparable resistance to fracture. Therefore, additional processing steps to eliminate the edge flaws in RIE patterned devices could result in significantly stronger microelectromechanical system components fabricated by conventional columnar polysilicon films.« less
NASA Astrophysics Data System (ADS)
Shedekar, Vinayak S.; King, Kevin W.; Fausey, Norman R.; Soboyejo, Alfred B. O.; Harmel, R. Daren; Brown, Larry C.
2016-09-01
Three different models of tipping bucket rain gauges (TBRs), viz. HS-TB3 (Hydrological Services Pty Ltd.), ISCO-674 (Isco, Inc.) and TR-525 (Texas Electronics, Inc.), were calibrated in the lab to quantify measurement errors across a range of rainfall intensities (5 mm·h- 1 to 250 mm·h- 1) and three different volumetric settings. Instantaneous and cumulative values of simulated rainfall were recorded at 1, 2, 5, 10 and 20-min intervals. All three TBR models showed a substantial deviation (α = 0.05) in measurements from actual rainfall depths, with increasing underestimation errors at greater rainfall intensities. Simple linear regression equations were developed for each TBR to correct the TBR readings based on measured intensities (R2 > 0.98). Additionally, two dynamic calibration techniques, viz. quadratic model (R2 > 0.7) and T vs. 1/Q model (R2 = > 0.98), were tested and found to be useful in situations when the volumetric settings of TBRs are unknown. The correction models were successfully applied to correct field-collected rainfall data from respective TBR models. The calibration parameters of correction models were found to be highly sensitive to changes in volumetric calibration of TBRs. Overall, the HS-TB3 model (with a better protected tipping bucket mechanism, and consistent measurement errors across a range of rainfall intensities) was found to be the most reliable and consistent for rainfall measurements, followed by the ISCO-674 (with susceptibility to clogging and relatively smaller measurement errors across a range of rainfall intensities) and the TR-525 (with high susceptibility to clogging and frequent changes in volumetric calibration, and highly intensity-dependent measurement errors). The study demonstrated that corrections based on dynamic and volumetric calibration can only help minimize-but not completely eliminate the measurement errors. The findings from this study will be useful for correcting field data from TBRs; and may have major implications to field- and watershed-scale hydrologic studies.
Error, stress, and teamwork in medicine and aviation: cross sectional surveys
NASA Technical Reports Server (NTRS)
Sexton, J. B.; Thomas, E. J.; Helmreich, R. L.
2000-01-01
OBJECTIVES: To survey operating theatre and intensive care unit staff about attitudes concerning error, stress, and teamwork and to compare these attitudes with those of airline cockpit crew. DESIGN:: Cross sectional surveys. SETTING:: Urban teaching and non-teaching hospitals in the United States, Israel, Germany, Switzerland, and Italy. Major airlines around the world. PARTICIPANTS:: 1033 doctors, nurses, fellows, and residents working in operating theatres and intensive care units and over 30 000 cockpit crew members (captains, first officers, and second officers). MAIN OUTCOME MEASURES:: Perceptions of error, stress, and teamwork. RESULTS:: Pilots were least likely to deny the effects of fatigue on performance (26% v 70% of consultant surgeons and 47% of consultant anaesthetists). Most pilots (97%) and intensive care staff (94%) rejected steep hierarchies (in which senior team members are not open to input from junior members), but only 55% of consultant surgeons rejected such hierarchies. High levels of teamwork with consultant surgeons were reported by 73% of surgical residents, 64% of consultant surgeons, 39% of anaesthesia consultants, 28% of surgical nurses, 25% of anaesthetic nurses, and 10% of anaesthetic residents. Only a third of staff reported that errors are handled appropriately at their hospital. A third of intensive care staff did not acknowledge that they make errors. Over half of intensive care staff reported that they find it difficult to discuss mistakes. CONCLUSIONS: Medical staff reported that error is important but difficult to discuss and not handled well in their hospital. Barriers to discussing error are more important since medical staff seem to deny the effect of stress and fatigue on performance. Further problems include differing perceptions of teamwork among team members and reluctance of senior theatre staff to accept input from junior members.
Error, stress, and teamwork in medicine and aviation: cross sectional surveys
Sexton, J Bryan; Thomas, Eric J; Helmreich, Robert L
2000-01-01
Objectives: To survey operating theatre and intensive care unit staff about attitudes concerning error, stress, and teamwork and to compare these attitudes with those of airline cockpit crew. Design: Cross sectional surveys. Setting: Urban teaching and non-teaching hospitals in the United States, Israel, Germany, Switzerland, and Italy. Major airlines around the world. Participants: 1033 doctors, nurses, fellows, and residents working in operating theatres and intensive care units and over 30 000 cockpit crew members (captains, first officers, and second officers). Main outcome measures: Perceptions of error, stress, and teamwork. Results: Pilots were least likely to deny the effects of fatigue on performance (26% v 70% of consultant surgeons and 47% of consultant anaesthetists). Most pilots (97%) and intensive care staff (94%) rejected steep hierarchies (in which senior team members are not open to input from junior members), but only 55% of consultant surgeons rejected such hierarchies. High levels of teamwork with consultant surgeons were reported by 73% of surgical residents, 64% of consultant surgeons, 39% of anaesthesia consultants, 28% of surgical nurses, 25% of anaesthetic nurses, and 10% of anaesthetic residents. Only a third of staff reported that errors are handled appropriately at their hospital. A third of intensive care staff did not acknowledge that they make errors. Over half of intensive care staff reported that they find it difficult to discuss mistakes. Conclusions: Medical staff reported that error is important but difficult to discuss and not handled well in their hospital. Barriers to discussing error are more important since medical staff seem to deny the effect of stress and fatigue on performance. Further problems include differing perceptions of teamwork among team members and reluctance of senior theatre staff to accept input from junior members. PMID:10720356
Rebamipide promotes healing of colonic ulceration through enhanced epithelial restitution.
Takagi, Tomohisa; Naito, Yuji; Uchiyama, Kazuhiko; Okuda, Toshimitsu; Mizushima, Katsura; Suzuki, Takahiro; Handa, Osamu; Ishikawa, Takeshi; Yagi, Nobuaki; Kokura, Satoshi; Ichikawa, Hiroshi; Yoshikawa, Toshikazu
2011-09-07
To investigate the efficacy of rebamipide in a rat model of colitis and restitution of intestinal epithelial cells in vitro. Acute colitis was induced with trinitrobenzene sulfonic acid (TNBS) in male Wistar rats. Rats received intrarectal rebamipide treatment daily starting on day 7 and were sacrificed on day 14 after TNBS administration. The distal colon was removed to evaluate the various parameters of inflammation. Moreover, wound healing assays were used to determine the enhanced restitution of rat intestinal epithelial (RIE) cells treated with rebamipide. Intracolonic administration of rebamipide accelerated TNBS-induced ulcer healing. Increases in the wet weight of the colon after TNBS administration were significantly inhibited by rebamipide. The wound assay revealed that rebamipide enhanced the migration of RIE cells through phosphorylation of extracellular signal-regulated kinase (ERK) and activation of Rho kinase. Rebamipide enema healed intestinal injury by enhancing restitution of RIE cells, via ERK activation. Rebamipide might be a novel therapeutic approach for inflammatory bowel disease.
Rebamipide promotes healing of colonic ulceration through enhanced epithelial restitution
Takagi, Tomohisa; Naito, Yuji; Uchiyama, Kazuhiko; Okuda, Toshimitsu; Mizushima, Katsura; Suzuki, Takahiro; Handa, Osamu; Ishikawa, Takeshi; Yagi, Nobuaki; Kokura, Satoshi; Ichikawa, Hiroshi; Yoshikawa, Toshikazu
2011-01-01
AIM: To investigate the efficacy of rebamipide in a rat model of colitis and restitution of intestinal epithelial cells in vitro. METHODS: Acute colitis was induced with trinitrobenzene sulfonic acid (TNBS) in male Wistar rats. Rats received intrarectal rebamipide treatment daily starting on day 7 and were sacrificed on day 14 after TNBS administration. The distal colon was removed to evaluate the various parameters of inflammation. Moreover, wound healing assays were used to determine the enhanced restitution of rat intestinal epithelial (RIE) cells treated with rebamipide. RESULTS: Intracolonic administration of rebamipide accelerated TNBS-induced ulcer healing. Increases in the wet weight of the colon after TNBS administration were significantly inhibited by rebamipide. The wound assay revealed that rebamipide enhanced the migration of RIE cells through phosphorylation of extracellular signal-regulated kinase (ERK) and activation of Rho kinase. CONCLUSION: Rebamipide enema healed intestinal injury by enhancing restitution of RIE cells, via ERK activation. Rebamipide might be a novel therapeutic approach for inflammatory bowel disease. PMID:21987622
Bunte Breccia of the Ries - Continuous deposits of large impact craters
NASA Technical Reports Server (NTRS)
Horz, F.; Ostertag, R.; Rainey, D. A.
1983-01-01
The 26-km-diameter Ries impact crater in south Germany and the mechanism of ejection and emplacement associated with its formation about 15 Myr ago are discussed in detail, and the implications of the findings for models of crater formation on earth, moon, and planets are considered. Field observations and laboratory tests on 560-m core materials from nine locations are reported. The continuous deposits (Bunte Breccia) are found to be a chaotic mixture resulting from deposition at ambient temperatures in a highly turbulent environment, probably in the ballistic scenario proposed by Oberbeck et al. (1975), with an emplacement time of only about 5 min. Further impact parameters are estimated using the 'Z model' of Maxwell (1977): initial radius = 6.5 km, excavation depth = 1650 m, excavation volume = 136 cu km, and transient cavity volume = 230 cu km. The interpretation of lunar and planetary remote-sensing and in situ evidence from impact craters is reviewed in the light of the Ries findings. Numerous photographs, maps, diagrams, and tables illustrate the investigation.
Technique for etching monolayer and multilayer materials
Bouet, Nathalie C. D.; Conley, Raymond P.; Divan, Ralu; Macrander, Albert
2015-10-06
A process is disclosed for sectioning by etching of monolayers and multilayers using an RIE technique with fluorine-based chemistry. In one embodiment, the process uses Reactive Ion Etching (RIE) alone or in combination with Inductively Coupled Plasma (ICP) using fluorine-based chemistry alone and using sufficient power to provide high ion energy to increase the etching rate and to obtain deeper anisotropic etching. In a second embodiment, a process is provided for sectioning of WSi.sub.2/Si multilayers using RIE in combination with ICP using a combination of fluorine-based and chlorine-based chemistries and using RF power and ICP power. According to the second embodiment, a high level of vertical anisotropy is achieved by a ratio of three gases; namely, CHF.sub.3, Cl.sub.2, and O.sub.2 with RF and ICP. Additionally, in conjunction with the second embodiment, a passivation layer can be formed on the surface of the multilayer which aids in anisotropic profile generation.
Little, Charles M; McStay, Christopher; Oeth, Justin; Koehler, April; Bookman, Kelly
2018-02-01
The use of after-action reviews (AARs) following major emergency events, such as a disaster, is common and mandated for hospitals and similar organizations. There is a recurrent challenge of identified problems not being resolved and repeated in subsequent events. A process improvement technique called a rapid improvement event (RIE) was used to conduct an AAR following a complete information technology (IT) outage at a large urban hospital. Using RIE methodology to conduct the AAR allowed for the rapid development and implementation of major process improvements to prepare for future IT downtime events. Thus, process improvement methodology, particularly the RIE, is suited for conducting AARs following disasters and holds promise for improving outcomes in emergency management. Little CM , McStay C , Oeth J , Koehler A , Bookman K . Using rapid improvement events for disaster after-action reviews: experience in a hospital information technology outage and response. Prehosp Disaster Med. 2018;33(1):98-100.
Les biofilms bactériens : leur importance en santé animale et en santé publique
Tremblay, Yannick D.N.; Hathroubi, Skander; Jacques, Mario
2014-01-01
Résumé Les biofilms bactériens sont des amas structurés de cellules bactériennes enrobés d’une matrice polymérique et attachés à une surface. Le biofilm protège les bactéries et leur permet de survivre dans des conditions environnementales hostiles. Les bactéries du biofilm peuvent résister à la réponse immunitaire de l’hôte et sont beaucoup plus résistantes aux antibiotiques et aux désinfectants que les cellules bactériennes planctoniques. La capacité de former un biofilm est maintenant reconnue comme une caractéristique propre à plusieurs microorganismes. La présence de biofilms lors d’infections demande donc de nouvelles méthodes de prévention, de diagnostic et de traitement. De même, la présence de biofilms sur des surfaces retrouvées à la ferme, à l’abattoir ou à l’usine de transformation affectera l’efficacité du protocole de désinfection. De façon surprenante, la formation de biofilms chez les bactéries pathogènes des animaux et les bactéries zoonotiques est un sujet relativement peu étudié. Ce bref compte rendu a pour objectif de sensibiliser les intervenants en santé animale à l’importance des biofilms. PMID:24688172
Manrique-Rodríguez, S; Sánchez-Galindo, A C; Fernández-Llamazares, C M; Calvo-Calvo, M M; Carrillo-Álvarez, Á; Sanjurjo-Sáez, M
2016-10-01
To estimate the impact of smart pump implementation in a pediatric intensive care unit in terms of number and type of administration errors intercepted. Observational, prospective study carried out from January 2010 to March 2015 with syringe and great volumen infusion pumps available in the hospital. A tertiary level hospital pediatric intensive care unit. Infusions delivered with infusion pumps in all pediatric intensive care unit patients. Design of a drug library with safety limits for all intravenous drugs prescribed. Users' compliance with drug library as well as number and type of errors prevented were analyzed. Two hundred and eighty-three errors were intercepted during 62 months of study. A high risk drug was involved in 58% of prevented errors, such as adrenergic agonists and antagonists, sedatives, analgesics, neuromuscular blockers, opioids, potassium and insulin. Users' average compliance with the safety software was 84%. Smart pumps implementation has proven effective in intercepting high risk drugs programming errors. These results might be exportable to other critical care units, involving pediatric or adult patients. Interdisciplinary colaboration is key to succeed in this process. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.
Hasani, Mohammad; Sakieh, Yousef; Dezhkam, Sadeq; Ardakani, Tahereh; Salmanmahiny, Abdolrassoul
2017-04-01
A hierarchical intensity analysis of land-use change is applied to evaluate the dynamics of a coupled urban coastal system in Rasht County, Iran. Temporal land-use layers of 1987, 1999, and 2011 are employed, while spatial accuracy metrics are only available for 2011 data (overall accuracy of 94%). The errors in 1987 and 1999 layers are unknown, which can influence the accuracy of temporal change information. Such data were employed to examine the size and the type of errors that could justify deviations from uniform change intensities. Accordingly, errors comprising 3.31 and 7.47% of 1999 and 2011 maps, respectively, could explain all differences from uniform gains and errors including 5.21 and 1.81% of 1987 and 1999 maps, respectively, could explain all deviations from uniform losses. Additional historical information is also applied for uncertainty assessment and to separate probable map errors from actual land-use changes. In this regard, historical processes in Rasht County can explain different types of transition that are either consistent or inconsistent to known processes. The intensity analysis assisted in identification of systematic transitions and detection of competitive categories, which cannot be investigated through conventional change detection methods. Based on results, built-up area is the most active gaining category in the area and wetland category with less areal extent is more sensitive to intense land-use change processes. Uncertainty assessment results also indicated that there are no considerable classification errors in temporal land-use data and these imprecise layers can reliably provide implications for informed decision making.
Pickering, Brian W; Hurley, Killian; Marsh, Brian
2009-11-01
To use a handover assessment tool for identifying patient information corruption and objectively evaluating interventions designed to reduce handover errors and improve medical decision making. The continuous monitoring, intervention, and evaluation of the patient in modern intensive care unit practice generates large quantities of information, the platform on which medical decisions are made. Information corruption, defined as errors of distortion/omission compared with the medical record, may result in medical judgment errors. Identifying these errors may lead to quality improvements in intensive care unit care delivery and safety. Handover assessment instrument development study divided into two phases by the introduction of a handover intervention. Closed, 17-bed, university-affiliated mixed surgical/medical intensive care unit. Senior and junior medical members of the intensive care unit team. Electronic handover page. Study subjects were asked to recall clinical information commonly discussed at handover on individual patients. The handover score measured the percentage of information correctly retained for each individual doctor-patient interaction. The clinical intention score, a subjective measure of medical judgment, was graded (1-5) by three blinded intensive care unit experts. A total of 137 interactions were scored. Median (interquartile range) handover scores for phases 1 and 2 were 79.07% (67.44-84.50) and 83.72% (76.16-88.37), respectively. Score variance was reduced by the handover intervention (p < .05). Increasing median handover scores, 68.60 to 83.72, were associated with increases in clinical intention scores from 1 to 5 (chi-square = 23.59, df = 4, p < .0001). When asked to recall clinical information discussed at handover, medical members of the intensive care unit team provide data that are significantly corrupted compared with the medical record. Low subjective clinical judgment scores are significant associated with low handover scores. The handover/clinical intention scores may, therefore, be useful screening tools for intensive care unit system vulnerability to medical error. Additionally, handover instruments can identify interventions that reduce system vulnerability to error and may be used to guide quality improvements in handover practice.
Wide-bandgap III-Nitride based Second Harmonic Generation
2014-10-02
fabrication process for a GaN LPS. Fig. 1: 3-step Fabrication process of a GaN based lateral polar structure. ( a ) Growth of a 20 nm AlN buffer layer...etching of the LT-AlN stripes. This results are shown in Fig. 2 ( a ) and (b). Fig. 2: AFM images of KOH ( a ) and RIE (b) patterned templates for lateral ...was varied between 0.6 - 1.0. FIG. 3: Growth process of AlGaN based Lateral Polar Structures. ( a ) RIE patterning. (b) Growth of HT- AlN. (c
A simple process to achieve microchannels geometries able to produce hydrodynamic cavitation
NASA Astrophysics Data System (ADS)
Qiu, X.; Cherief, W.; Colombet, D.; Ayela, F.
2017-04-01
We present a simple process to perform microchannels in which cavitating two phase flows are easily producible. Up to now, hydrodynamic cavitation ‘on a chip’ was reached with small flow rates inside microchannels whose micromachining had involved a deep reactive ion etching (D-RIE). The process we present here does not require a D-RIE reactor, as it is only funded on a wet etching of silicon. It leads to a so-called microstep profile, and large cavitating flow rates become possible together with moderate pressure drops.
Koetsier, Antonie; Peek, Niels; de Keizer, Nicolette
2012-01-01
Errors may occur in the registration of in-hospital mortality, making it less reliable as a quality indicator. We assessed the types of errors made in in-hospital mortality registration in the clinical quality registry National Intensive Care Evaluation (NICE) by comparing its mortality data to data from a national insurance claims database. Subsequently, we performed site visits at eleven Intensive Care Units (ICUs) to investigate the number, types and causes of errors made in in-hospital mortality registration. A total of 255 errors were found in the NICE registry. Two different types of software malfunction accounted for almost 80% of the errors. The remaining 20% were five types of manual transcription errors and human failures to record outcome data. Clinical registries should be aware of the possible existence of errors in recorded outcome data and understand their causes. In order to prevent errors, we recommend to thoroughly verify the software that is used in the registration process.
Reducing medication errors in critical care: a multimodal approach
Kruer, Rachel M; Jarrell, Andrew S; Latif, Asad
2014-01-01
The Institute of Medicine has reported that medication errors are the single most common type of error in health care, representing 19% of all adverse events, while accounting for over 7,000 deaths annually. The frequency of medication errors in adult intensive care units can be as high as 947 per 1,000 patient-days, with a median of 105.9 per 1,000 patient-days. The formulation of drugs is a potential contributor to medication errors. Challenges related to drug formulation are specific to the various routes of medication administration, though errors associated with medication appearance and labeling occur among all drug formulations and routes of administration. Addressing these multifaceted challenges requires a multimodal approach. Changes in technology, training, systems, and safety culture are all strategies to potentially reduce medication errors related to drug formulation in the intensive care unit. PMID:25210478
The effects of center of rotation errors on cardiac SPECT imaging
NASA Astrophysics Data System (ADS)
Bai, Chuanyong; Shao, Ling; Ye, Jinghan; Durbin, M.
2003-10-01
In SPECT imaging, center of rotation (COR) errors lead to the misalignment of projection data and can potentially degrade the quality of the reconstructed images. In this work, we study the effects of COR errors on cardiac SPECT imaging using simulation, point source, cardiac phantom, and patient studies. For simulation studies, we generate projection data using a uniform MCAT phantom first without modeling any physical effects (NPH), then with the modeling of detector response effect (DR) alone. We then corrupt the projection data with simulated sinusoid and step COR errors. For other studies, we introduce sinusoid COR errors to projection data acquired on SPECT systems. An OSEM algorithm is used for image reconstruction without detector response correction, but with nonuniform attenuation correction when needed. The simulation studies show that, when COR errors increase from 0 to 0.96 cm: 1) sinusoid COR errors in axial direction lead to intensity decrease in the inferoapical region; 2) step COR errors in axial direction lead to intensity decrease in the distal anterior region. The intensity decrease is more severe in images reconstructed from projection data with NPH than with DR; and 3) the effects of COR errors in transaxial direction seem to be insignificant. In other studies, COR errors slightly degrade point source resolution; COR errors of 0.64 cm or above introduce visible but insignificant nonuniformity in the images of uniform cardiac phantom; COR errors up to 0.96 cm in transaxial direction affect the lesion-to-background contrast (LBC) insignificantly in the images of cardiac phantom with defects, and COR errors up to 0.64 cm in axial direction only slightly decrease the LBC. For the patient studies with COR errors up to 0.96 cm, images have the same diagnostic/prognostic values as those without COR errors. This work suggests that COR errors of up to 0.64 cm are not likely to change the clinical applications of cardiac SPECT imaging when using iterative reconstruction algorithm without detector response correction.
Error Analysis in Academic Writing: A Case of International Postgraduate Students in Malaysia
ERIC Educational Resources Information Center
Amiri, Fatemeh; Puteh, Marlia
2017-01-01
This paper examines the different types of writing errors performed by 16 international postgraduate students undertaking an intensive English course at a public university in Malaysia. It was mandatory for international postgraduate students who obtained less than IELTS Band 6 to undertake an Intensive English Course (IEC) offered by the…
Sada, Oumer; Melkie, Addisu; Shibeshi, Workineh
2015-09-16
Medication errors (MEs) are important problems in all hospitalized populations, especially in intensive care unit (ICU). Little is known about the prevalence of medication prescribing errors in the ICU of hospitals in Ethiopia. The aim of this study was to assess medication prescribing errors in the ICU of Tikur Anbessa Specialized Hospital using retrospective cross-sectional analysis of patient cards and medication charts. About 220 patient charts were reviewed with a total of 1311 patient-days, and 882 prescription episodes. 359 MEs were detected; with prevalence of 40 per 100 orders. Common prescribing errors were omission errors 154 (42.89%), 101 (28.13%) wrong combination, 48 (13.37%) wrong abbreviation, 30 (8.36%) wrong dose, wrong frequency 18 (5.01%) and wrong indications 8 (2.23%). The present study shows that medication errors are common in medical ICU of Tikur Anbessa Specialized Hospital. These results suggest future targets of prevention strategies to reduce the rate of medication error.
Radiography Capabilities for Matter-Radiation Interactions in Extremes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walstrom, Peter Lowell; Garnett, Robert William; Chapman, Catherine A. B
The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electronmore » and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.« less
Processing-Induced Electrically Active Defects in Black Silicon Nanowire Devices.
Carapezzi, Stefania; Castaldini, Antonio; Mancarella, Fulvio; Poggi, Antonella; Cavallini, Anna
2016-04-27
Silicon nanowires (Si NWs) are widely investigated nowadays for implementation in advanced energy conversion and storage devices, as well as many other possible applications. Black silicon (BSi)-NWs are dry etched NWs that merge the advantages related to low-dimensionality with the special industrial appeal connected to deep reactive ion etching (RIE). In fact, RIE is a well established technique in microelectronics manufacturing. However, RIE processing could affect the electrical properties of BSi-NWs by introducing deep states into their forbidden gap. This work applies deep level transient spectroscopy (DLTS) to identify electrically active deep levels and the associated defects in dry etched Si NW arrays. Besides, the successful fitting of DLTS spectra of BSi-NWs-based Schottky barrier diodes is an experimental confirmation that the same theoretical framework of dynamic electronic behavior of deep levels applies in bulk as well as in low dimensional structures like NWs, when quantum confinement conditions do not occur. This has been validated for deep levels associated with simple pointlike defects as well as for deep levels associated with defects with richer structures, whose dynamic electronic behavior implies a more complex picture.
Evaluation of normalization methods for cDNA microarray data by k-NN classification
Wu, Wei; Xing, Eric P; Myers, Connie; Mian, I Saira; Bissell, Mina J
2005-01-01
Background Non-biological factors give rise to unwanted variations in cDNA microarray data. There are many normalization methods designed to remove such variations. However, to date there have been few published systematic evaluations of these techniques for removing variations arising from dye biases in the context of downstream, higher-order analytical tasks such as classification. Results Ten location normalization methods that adjust spatial- and/or intensity-dependent dye biases, and three scale methods that adjust scale differences were applied, individually and in combination, to five distinct, published, cancer biology-related cDNA microarray data sets. Leave-one-out cross-validation (LOOCV) classification error was employed as the quantitative end-point for assessing the effectiveness of a normalization method. In particular, a known classifier, k-nearest neighbor (k-NN), was estimated from data normalized using a given technique, and the LOOCV error rate of the ensuing model was computed. We found that k-NN classifiers are sensitive to dye biases in the data. Using NONRM and GMEDIAN as baseline methods, our results show that single-bias-removal techniques which remove either spatial-dependent dye bias (referred later as spatial effect) or intensity-dependent dye bias (referred later as intensity effect) moderately reduce LOOCV classification errors; whereas double-bias-removal techniques which remove both spatial- and intensity effect reduce LOOCV classification errors even further. Of the 41 different strategies examined, three two-step processes, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, all of which removed intensity effect globally and spatial effect locally, appear to reduce LOOCV classification errors most consistently and effectively across all data sets. We also found that the investigated scale normalization methods do not reduce LOOCV classification error. Conclusion Using LOOCV error of k-NNs as the evaluation criterion, three double-bias-removal normalization strategies, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, outperform other strategies for removing spatial effect, intensity effect and scale differences from cDNA microarray data. The apparent sensitivity of k-NN LOOCV classification error to dye biases suggests that this criterion provides an informative measure for evaluating normalization methods. All the computational tools used in this study were implemented using the R language for statistical computing and graphics. PMID:16045803
Evaluation of normalization methods for cDNA microarray data by k-NN classification.
Wu, Wei; Xing, Eric P; Myers, Connie; Mian, I Saira; Bissell, Mina J
2005-07-26
Non-biological factors give rise to unwanted variations in cDNA microarray data. There are many normalization methods designed to remove such variations. However, to date there have been few published systematic evaluations of these techniques for removing variations arising from dye biases in the context of downstream, higher-order analytical tasks such as classification. Ten location normalization methods that adjust spatial- and/or intensity-dependent dye biases, and three scale methods that adjust scale differences were applied, individually and in combination, to five distinct, published, cancer biology-related cDNA microarray data sets. Leave-one-out cross-validation (LOOCV) classification error was employed as the quantitative end-point for assessing the effectiveness of a normalization method. In particular, a known classifier, k-nearest neighbor (k-NN), was estimated from data normalized using a given technique, and the LOOCV error rate of the ensuing model was computed. We found that k-NN classifiers are sensitive to dye biases in the data. Using NONRM and GMEDIAN as baseline methods, our results show that single-bias-removal techniques which remove either spatial-dependent dye bias (referred later as spatial effect) or intensity-dependent dye bias (referred later as intensity effect) moderately reduce LOOCV classification errors; whereas double-bias-removal techniques which remove both spatial- and intensity effect reduce LOOCV classification errors even further. Of the 41 different strategies examined, three two-step processes, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, all of which removed intensity effect globally and spatial effect locally, appear to reduce LOOCV classification errors most consistently and effectively across all data sets. We also found that the investigated scale normalization methods do not reduce LOOCV classification error. Using LOOCV error of k-NNs as the evaluation criterion, three double-bias-removal normalization strategies, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, outperform other strategies for removing spatial effect, intensity effect and scale differences from cDNA microarray data. The apparent sensitivity of k-NN LOOCV classification error to dye biases suggests that this criterion provides an informative measure for evaluating normalization methods. All the computational tools used in this study were implemented using the R language for statistical computing and graphics.
NASA Astrophysics Data System (ADS)
Pirkenseer, C.; Spezzaferri, S.; Berger, J.-P.
2009-04-01
During the Late Rupelian the widespread second transgression (corresponding to international Ru2-3 transgressions; BERGER et al. 2005) affected the whole Upper Rhine Graben basin and led to the deposition of the several hundred meters thick marine "Série grise". An abrupt transition (erosion surface) between the uppermost "Série grise" and Niederroedern Formation indicates the change to fluviatile and lacustrine conditions throughout the basin close to the Late Rupelian / Early Chattian boundary. Abundant reworked Middle to Late Cretaceous (e.g., Marginotruncana pseudolinneiana) and Late Paleocene to Late Eocene (e.g., Acarinina bullbrooki, Morozovella subbotinae, Turborotalia cocoaensis) ranging planktonic Foraminifera occur in the "Série Grise" and equivalent lithological units of the Upper Rhine Graben and the Mainz Basin (e.g., FISCHER 1965, PIRKENSEER 2007, SCHÄFER & KUHN 2004). At least Late Cretaceous, Ypresian, Lutetian and Priabonian ages of source sediments are indicated by the overlapping biostratigraphic ranges of the reworked specimens. Abundant reworked material first appears in the lower "Couches à Mélettes" and reaches its acme in the increasingly "Marnes à Cyrènes" (terminal "Série grise"). Only sparse records are documented from the subsequent terrestrial Niederroedern Formation. These reworking events are linked to intervals of increased clastic input throughout the "Série grise". The planktonic Foraminifera are proposed to be reworked from related alpine deposits (later Helvetikum?) via a northwards trending fluviatile system, as no autochthonous Cretaceous and Early to Middle Eocene marine sediments were deposited within the graben basin. Furthermore other possible source areas (e.g., Paris Basin) were either not connected to the Upper Rhine Graben or were not subject to erosion in the Late Rupelian. This accords with the proposition (ROUSSÉ 2006) of a vast northwards prograding delta-system that was located close to the southern margin of the Upper Rhine Graben. Reworked Mesozoic and Paleogene calcareous nannoplankton from the Upper Rhine Graben and the Mainz Basin confirms the data derived from planktonic Foraminifera. The existence of reworked planktonic Foraminifera influences the biostratigraphic interpretation of the assemblage ranges attributed to "Série grise" samples. Facultatively reworked planktonic Foraminifera as Subbotina utilisindex and Pseudohastigerina micra ranging from the Lutetian to the Late Rupelian should not be included in the biostratigraphic analyses, as the occurrences of these facultatively reworked species are always linked to those of exclusively Cretaceous and Eocene age. Therefore the age of the "Série grise" deposits at Allschwil-2 is most likely to be placed within the "Chiloguembelina cubensis - Globigerinella obesa / Globorotaloides variabilis"-assemblage range of Mid P20 to Final P21a, lasting considerably longer than the very short Mid P20 range based on the presence of Pseudohastigerina micra as "last occurrence"-marker (PIRKENSEER 2007). This study was funded by the Swiss National Science Foundation projects 109457 and 118025. References: BERGER, J.-P., REICHENBACHER, B., BECKER, D., et al. (2005): Eocene-Pliocene time scale and stratigraphy of the Upper Rhine Graben (URG) and the Swiss Molasse Basin (SMB). - International Journal of Earth Sciences, 94, 4: 711-731. FISCHER, H. (1965): Geologie des Gebietes zwischen Blauen und Pfirter Jura. - Beiträge zur geologischen Karte der Schweiz, NF 122: 106p. PIRKENSEER, C. (2007): Foraminifera, Ostracoda and other microfossils of the Southern Upper Rhine Graben - Palaeoecology, biostratigraphy, palaeogeography and geodynamic implications. - PhD thesis: 340p, Fribourg. ROUSSÉ, S. (2006): Architecture et dynamique des séries marines et continentales de ĺOligocène Moyen et Supérieur du Sud du Fossé Rhénan: Evolution des milieux de dépôt en contexte de rift en marge de ĺavant-pays alpin. - PhD: 471p, Strasbourg. SCHÄFER, P. & KUHN, W. (2004): Mikropaläontologische und lithologische Abgrenzungskriterien zwischen Oberem Rupelton [= Rosenberg-Subformation] und "Schleichsand" [= Stadecken-Formation] im Rupelium (Tertiär) des Mainzer Beckens. - Mainzer geowissenschaftliche Mitteilungen, 32: 139-178.
Alastruey, Jordi; Hunt, Anthony A E; Weinberg, Peter D
2014-01-01
We present a novel analysis of arterial pulse wave propagation that combines traditional wave intensity analysis with identification of Windkessel pressures to account for the effect on the pressure waveform of peripheral wave reflections. Using haemodynamic data measured in vivo in the rabbit or generated numerically in models of human compliant vessels, we show that traditional wave intensity analysis identifies the timing, direction and magnitude of the predominant waves that shape aortic pressure and flow waveforms in systole, but fails to identify the effect of peripheral reflections. These reflections persist for several cardiac cycles and make up most of the pressure waveform, especially in diastole and early systole. Ignoring peripheral reflections leads to an erroneous indication of a reflection-free period in early systole and additional error in the estimates of (i) pulse wave velocity at the ascending aorta given by the PU–loop method (9.5% error) and (ii) transit time to a dominant reflection site calculated from the wave intensity profile (27% error). These errors decreased to 1.3% and 10%, respectively, when accounting for peripheral reflections. Using our new analysis, we investigate the effect of vessel compliance and peripheral resistance on wave intensity, peripheral reflections and reflections originating in previous cardiac cycles. PMID:24132888
Levesque, Eric; Hoti, Emir; de La Serna, Sofia; Habouchi, Houssam; Ichai, Philippe; Saliba, Faouzi; Samuel, Didier; Azoulay, Daniel
2013-03-01
In the French healthcare system, the intensive care budget allocated is directly dependent on the activity level of the center. To evaluate this activity level, it is necessary to code the medical diagnoses and procedures performed on Intensive Care Unit (ICU) patients. The aim of this study was to evaluate the effects of using an Intensive Care Information System (ICIS) on the incidence of coding errors and its impact on the ICU budget allocated. Since 2005, the documentation on and monitoring of every patient admitted to our ICU has been carried out using an ICIS. However, the coding process was performed manually until 2008. This study focused on two periods: the period of manual coding (year 2007) and the period of computerized coding (year 2008) which covered a total of 1403 ICU patients. The time spent on the coding process, the rate of coding errors (defined as patients missed/not coded or wrongly identified as undergoing major procedure/s) and the financial impact were evaluated for these two periods. With computerized coding, the time per admission decreased significantly (from 6.8 ± 2.8 min in 2007 to 3.6 ± 1.9 min in 2008, p<0.001). Similarly, a reduction in coding errors was observed (7.9% vs. 2.2%, p<0.001). This decrease in coding errors resulted in a reduced difference between the potential and real ICU financial supplements obtained in the respective years (€194,139 loss in 2007 vs. a €1628 loss in 2008). Using specific computer programs improves the intensive process of manual coding by shortening the time required as well as reducing errors, which in turn positively impacts the ICU budget allocation. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
MaRIE X-Ray Free-Electron Laser Pre-Conceptual Design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlsten, Bruce E.; Barnes, Cris W.; Bishofberger, Kip A.
2011-01-01
The proposed Matter-Radiation Interactions in Extremes (MaRIE) facility at the Los Alamos National Laboratory will include a 50-keV X-Ray Free-Electron Laser (XFEL), a significant extension from planned and existing XFEL facilities. To prevent an unacceptably large energy spread arsing from energy diffusion, the electron beam energy should not exceed 20 GeV, which puts a significant constraint on the beam emittance. A 100-pC baseline design is presented along with advanced technology options to increase the photon flux and to decrease the spectral bandwidth through pre-bunching the electron beam.
Sové, Richard J; Drakos, Nicole E; Fraser, Graham M; Ellis, Christopher G
2018-05-25
Red blood cell oxygen saturation is an important indicator of oxygen supply to tissues in the body. Oxygen saturation can be measured by taking advantage of spectroscopic properties of hemoglobin. When this technique is applied to transmission microscopy, the calculation of saturation requires determination of incident light intensity at each pixel occupied by the red blood cell; this value is often approximated from a sequence of images as the maximum intensity over time. This method often fails when the red blood cells are moving too slowly, or if hematocrit is too large since there is not a large enough gap between the cells to accurately calculate the incident intensity value. A new method of approximating incident light intensity is proposed using digital inpainting. This novel approach estimates incident light intensity with an average percent error of approximately 3%, which exceeds the accuracy of the maximum intensity based method in most cases. The error in incident light intensity corresponds to a maximum error of approximately 2% saturation. Therefore, though this new method is computationally more demanding than the traditional technique, it can be used in cases where the maximum intensity-based method fails (e.g. stationary cells), or when higher accuracy is required. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Ghost hunting—an assessment of ghost particle detection and removal methods for tomographic-PIV
NASA Astrophysics Data System (ADS)
Elsinga, G. E.; Tokgoz, S.
2014-08-01
This paper discusses and compares several methods, which aim to remove spurious peaks, i.e. ghost particles, from the volume intensity reconstruction in tomographic-PIV. The assessment is based on numerical simulations of time-resolved tomographic-PIV experiments in linear shear flows. Within the reconstructed volumes, intensity peaks are detected and tracked over time. These peaks are associated with particles (either ghosts or actual particles) and are characterized by their peak intensity, size and track length. Peak intensity and track length are found to be effective in discriminating between most ghosts and the actual particles, although not all ghosts can be detected using only a single threshold. The size of the reconstructed particles does not reveal an important difference between ghosts and actual particles. The joint distribution of peak intensity and track length however does, under certain conditions, allow a complete separation of ghosts and actual particles. The ghosts can have either a high intensity or a long track length, but not both combined, like all the actual particles. Removing the detected ghosts from the reconstructed volume and performing additional MART iterations can decrease the particle position error at low to moderate seeding densities, but increases the position error, velocity error and tracking errors at higher densities. The observed trends in the joint distribution of peak intensity and track length are confirmed by results from a real experiment in laminar Taylor-Couette flow. This diagnostic plot allows an estimate of the number of ghosts that are indistinguishable from the actual particles.
Performance Errors in Weight Training and Their Correction.
ERIC Educational Resources Information Center
Downing, John H.; Lander, Jeffrey E.
2002-01-01
Addresses general performance errors in weight training, also discussing each category of error separately. The paper focuses on frequency and intensity, incorrect training velocities, full range of motion, and symmetrical training. It also examines specific errors related to the bench press, squat, military press, and bent- over and seated row…
A theoretical basis for the analysis of multiversion software subject to coincident errors
NASA Technical Reports Server (NTRS)
Eckhardt, D. E., Jr.; Lee, L. D.
1985-01-01
Fundamental to the development of redundant software techniques (known as fault-tolerant software) is an understanding of the impact of multiple joint occurrences of errors, referred to here as coincident errors. A theoretical basis for the study of redundant software is developed which: (1) provides a probabilistic framework for empirically evaluating the effectiveness of a general multiversion strategy when component versions are subject to coincident errors, and (2) permits an analytical study of the effects of these errors. An intensity function, called the intensity of coincident errors, has a central role in this analysis. This function describes the propensity of programmers to introduce design faults in such a way that software components fail together when executing in the application environment. A condition under which a multiversion system is a better strategy than relying on a single version is given.
Automatic training and reliability estimation for 3D ASM applied to cardiac MRI segmentation
NASA Astrophysics Data System (ADS)
Tobon-Gomez, Catalina; Sukno, Federico M.; Butakoff, Constantine; Huguet, Marina; Frangi, Alejandro F.
2012-07-01
Training active shape models requires collecting manual ground-truth meshes in a large image database. While shape information can be reused across multiple imaging modalities, intensity information needs to be imaging modality and protocol specific. In this context, this study has two main purposes: (1) to test the potential of using intensity models learned from MRI simulated datasets and (2) to test the potential of including a measure of reliability during the matching process to increase robustness. We used a population of 400 virtual subjects (XCAT phantom), and two clinical populations of 40 and 45 subjects. Virtual subjects were used to generate simulated datasets (MRISIM simulator). Intensity models were trained both on simulated and real datasets. The trained models were used to segment the left ventricle (LV) and right ventricle (RV) from real datasets. Segmentations were also obtained with and without reliability information. Performance was evaluated with point-to-surface and volume errors. Simulated intensity models obtained average accuracy comparable to inter-observer variability for LV segmentation. The inclusion of reliability information reduced volume errors in hypertrophic patients (EF errors from 17 ± 57% to 10 ± 18% LV MASS errors from -27 ± 22 g to -14 ± 25 g), and in heart failure patients (EF errors from -8 ± 42% to -5 ± 14%). The RV model of the simulated images needs further improvement to better resemble image intensities around the myocardial edges. Both for real and simulated models, reliability information increased segmentation robustness without penalizing accuracy.
Automatic training and reliability estimation for 3D ASM applied to cardiac MRI segmentation.
Tobon-Gomez, Catalina; Sukno, Federico M; Butakoff, Constantine; Huguet, Marina; Frangi, Alejandro F
2012-07-07
Training active shape models requires collecting manual ground-truth meshes in a large image database. While shape information can be reused across multiple imaging modalities, intensity information needs to be imaging modality and protocol specific. In this context, this study has two main purposes: (1) to test the potential of using intensity models learned from MRI simulated datasets and (2) to test the potential of including a measure of reliability during the matching process to increase robustness. We used a population of 400 virtual subjects (XCAT phantom), and two clinical populations of 40 and 45 subjects. Virtual subjects were used to generate simulated datasets (MRISIM simulator). Intensity models were trained both on simulated and real datasets. The trained models were used to segment the left ventricle (LV) and right ventricle (RV) from real datasets. Segmentations were also obtained with and without reliability information. Performance was evaluated with point-to-surface and volume errors. Simulated intensity models obtained average accuracy comparable to inter-observer variability for LV segmentation. The inclusion of reliability information reduced volume errors in hypertrophic patients (EF errors from 17 ± 57% to 10 ± 18%; LV MASS errors from -27 ± 22 g to -14 ± 25 g), and in heart failure patients (EF errors from -8 ± 42% to -5 ± 14%). The RV model of the simulated images needs further improvement to better resemble image intensities around the myocardial edges. Both for real and simulated models, reliability information increased segmentation robustness without penalizing accuracy.
Segmented Mirror Image Degradation Due to Surface Dust, Alignment and Figure
NASA Technical Reports Server (NTRS)
Schreur, Julian J.
1999-01-01
In 1996 an algorithm was developed to include the effects of surface roughness in the calculation of the point spread function of a telescope mirror. This algorithm has been extended to include the effects of alignment errors and figure errors for the individual elements, and an overall contamination by surface dust. The final algorithm builds an array for a guard-banded pupil function of a mirror that may or may not have a central hole, a central reflecting segment, or an outer ring of segments. The central hole, central reflecting segment, and outer ring may be circular or polygonal, and the outer segments may have trimmed comers. The modeled point spread functions show that x-tilt and y-tilt, or the corresponding R-tilt and theta-tilt for a segment in an outer ring, is readily apparent for maximum wavefront errors of 0.1 lambda. A similar sized piston error is also apparent, but integral wavelength piston errors are not. Severe piston error introduces a focus error of the opposite sign, so piston could be adjusted to compensate for segments with varying focal lengths. Dust affects the image principally by decreasing the Strehl ratio, or peak intensity of the image. For an eight-meter telescope a 25% coverage by dust produced a scattered light intensity of 10(exp -9) of the peak intensity, a level well below detectability.
Sobre o uso das séries de Puiseux em mecanica celeste
NASA Astrophysics Data System (ADS)
Miloni, O. I.
2003-08-01
Neste trabalho é apresentada uma demonstração do uso dos diferentes desenvolvimentos em séries para as equações de perturbação em Mecânica Celeste no marco Hamiltoniano. Em trabalhos clássicos como os de Poincaré (Poincaré, 1893) por exemplo, já esta planteado o uso de potências não inteiras no pequeno parâmetro, o que evidencia a não analiticidade das funções quando uma ressonância ocorre. Nestes trabalhos os desenvolvimentos são na raíz quadrada da massa de Júpiter (o pequeno parâmetro). Mais recentemente (Ferraz-Mello, 1985) outros tipos de desenvolvimentos foram aplicados modificando substancialmente as ordens de grandeza e a velocidade de convergência das séries. Com esta abordagem, os desenvolvimentos foram expressados em termos da raíz cúbica do pequeno parâmetro. Neste trabalho apresentamos um enfoque geral, onde os diferentes tipos de desenvolvimentos em séries de Puiseux (Valiron, 1950) são obtidos a partir da aplicação de Teorema de Preparação de Weierstrass (Goursat, 1916) considerando a equação de Hamilton-Jacobi como uma equação algébrica. Os resultados são aplicados ao problema restrito dos três corpos em ressonância de primeira ordem e, dependendo da grandeza da excentricidade do asteróide em relação à de Júpiter, obtemos os diferentes desenvolvimentos, em raíz quadrada ou raíz cúbica da massa de Júpiter.
Surface passivation of nano-textured fluorescent SiC by atomic layer deposited TiO2
NASA Astrophysics Data System (ADS)
Lu, Weifang; Ou, Yiyu; Jokubavicius, Valdas; Fadil, Ahmed; Syväjärvi, Mikael; Petersen, Paul Michael; Ou, Haiyan
2016-07-01
Nano-textured surfaces have played a key role in optoelectronic materials to enhance the light extraction efficiency. In this work, morphology and optical properties of nano-textured SiC covered with atomic layer deposited (ALD) TiO2 were investigated. In order to obtain a high quality surface for TiO2 deposition, a three-step cleaning procedure was introduced after RIE etching. The morphology of anatase TiO2 indicates that the nano-textured substrate has a much higher surface nucleated grain density than a flat substrate at the beginning of the deposition process. The corresponding reflectance increases with TiO2 thickness due to increased surface diffuse reflection. The passivation effect of ALD TiO2 thin film on the nano-textured fluorescent 6H-SiC sample was also investigated and a PL intensity improvement of 8.05% was obtained due to the surface passivation.
McMahon, Ryan; Papiez, Lech; Rangaraj, Dharanipathy
2007-08-01
An algorithm is presented that allows for the control of multileaf collimation (MLC) leaves based entirely on real-time calculations of the intensity delivered over the target. The algorithm is capable of efficiently correcting generalized delivery errors without requiring the interruption of delivery (self-correcting trajectories), where a generalized delivery error represents anything that causes a discrepancy between the delivered and intended intensity profiles. The intensity actually delivered over the target is continually compared to its intended value. For each pair of leaves, these comparisons are used to guide the control of the following leaf and keep this discrepancy below a user-specified value. To demonstrate the basic principles of the algorithm, results of corrected delivery are shown for a leading leaf positional error during dynamic-MLC (DMLC) IMRT delivery over a rigid moving target. It is then shown that, with slight modifications, the algorithm can be used to track moving targets in real time. The primary results of this article indicate that the algorithm is capable of accurately delivering DMLC IMRT over a rigid moving target whose motion is (1) completely unknown prior to delivery and (2) not faster than the maximum MLC leaf velocity over extended periods of time. These capabilities are demonstrated for clinically derived intensity profiles and actual tumor motion data, including situations when the target moves in some instances faster than the maximum admissible MLC leaf velocity. The results show that using the algorithm while calculating the delivered intensity every 50 ms will provide a good level of accuracy when delivering IMRT over a rigid moving target translating along the direction of MLC leaf travel. When the maximum velocities of the MLC leaves and target were 4 and 4.2 cm/s, respectively, the resulting error in the two intensity profiles used was 0.1 +/- 3.1% and -0.5 +/- 2.8% relative to the maximum of the intensity profiles. For the same target motion, the error was shown to increase rapidly as (1) the maximum MLC leaf velocity was reduced below 75% of the maximum target velocity and (2) the system response time was increased.
Decoy-state quantum key distribution with more than three types of photon intensity pulses
NASA Astrophysics Data System (ADS)
Chau, H. F.
2018-04-01
The decoy-state method closes source security loopholes in quantum key distribution (QKD) using a laser source. In this method, accurate estimates of the detection rates of vacuum and single-photon events plus the error rate of single-photon events are needed to give a good enough lower bound of the secret key rate. Nonetheless, the current estimation method for these detection and error rates, which uses three types of photon intensities, is accurate up to about 1 % relative error. Here I report an experimentally feasible way that greatly improves these estimates and hence increases the one-way key rate of the BB84 QKD protocol with unbiased bases selection by at least 20% on average in realistic settings. The major tricks are the use of more than three types of photon intensities plus the fact that estimating bounds of the above detection and error rates is numerically stable, although these bounds are related to the inversion of a high condition number matrix.
Laurent, Alexandra; Aubert, Laurence; Chahraoui, Khadija; Bioy, Antoine; Mariage, André; Quenot, Jean-Pierre; Capellier, Gilles
2014-11-01
To identify the psychological repercussions of an error on professionals in intensive care and to understand their evolution. To identify the psychological defense mechanisms used by professionals to cope with error. Qualitative study with clinical interviews. We transcribed recordings and analysed the data using an interpretative phenomenological analysis. Two ICUs in the teaching hospitals of Besançon and Dijon (France). Fourteen professionals in intensive care (20 physicians and 20 nurses). None. We conducted 40 individual semistructured interviews. The participants were invited to speak about the experience of error in ICU. The interviews were transcribed and analyzed thematically by three experts. In the month following the error, the professionals described feelings of guilt (53.8%) and shame (42.5%). These feelings were associated with anxiety states with rumination (37.5%) and fear for the patient (23%); a loss of confidence (32.5%); an inability to verbalize one's error (22.5%); questioning oneself at a professional level (20%); and anger toward the team (15%). In the long term, the error remains fixed in memory for many of the subjects (80%); on one hand, for 72.5%, it was associated with an increase in vigilance and verifications in their professional practice, and on the other hand, for three professionals, it was associated with a loss of confidence. Finally, three professionals felt guilt which still persisted at the time of the interview. We also observed different defense mechanisms implemented by the professional to fight against the emotional load inherent in the error: verbalization (70%), developing skills and knowledge (43%), rejecting responsibility (32.5%), and avoidance (23%). We also observed a minimization (60%) of the error during the interviews. It is important to take into account the psychological experience of error and the defense mechanisms developed following an error because they appear to determine the professional's capacity to acknowledge and disclose his/her error and to learn from it.
Low-Power RIE of SiO2 in CHF3 To Obtain Steep Sidewalls
NASA Technical Reports Server (NTRS)
Turner, Tasha; Wu, Chi
2003-01-01
A reactive-ion etching (RIE) process has been developed to enable the formation of holes with steep sidewalls in a layer of silicon dioxide that covers a silicon substrate. The holes in question are through the thickness of the SiO2 and are used to define silicon substrate areas to be etched or to be built upon through epitaxial deposition of silicon. The sidewalls of these holes are required to be vertical in order to ensure that the sidewalls of the holes to be etched in the substrate or the sidewalls of the epitaxial deposits, respectively, also turn out to be vertical.
NASA Astrophysics Data System (ADS)
Barnes, Cris W.; Fernández, Juan; Hartsfield, Thomas; Sandberg, Richard; Sheffield, Richard; Tapia, John P.; Wang, Zhehui
2017-06-01
NNSA does not have a capability to understand and test the response of materials and conditions necessary to determine the linkages between microstructure of materials and performance in extreme weapons-relevant environments. Required is an x-ray source, coherent to optimize imaging capability, brilliant and high repetition-rate to address all relevant time scales, and with high enough energy to see into and through the amount of material in the middle or mesoscale where microstructure determines materials response. The Department of Energy has determined there is a mission need for a MaRIE Project to deliver this capability. There are risks to the Project to successfully deliver all the technology needed to provide the capability for the mission need and to use those photons to control the time-dependent production and performance of materials. The present technology risk mitigation activities for the MaRIE project are: developing ultrafast high-energy x-ray detectors, combining the data from several imaging probes to obtain multi-dimensional information about the sample, and developing techniques for bulk dynamic measurements of temperature. This talk will describe these efforts and other critical technology elements requiring future investment by the project.
Ye, Xin; Shao, Ting; Sun, Laixi; Wu, Jingjun; Wang, Fengrui; He, Junhui; Jiang, Xiaodong; Wu, Wei-Dong; Zheng, Wanguo
2018-04-25
In this work, antireflective and superhydrophilic subwavelength nanostructured fused silica surfaces have been created by one-step, self-masking reactive ion etching (RIE). Bare fused silica substrates with no mask were placed in a RIE vacuum chamber, and then nanoscale fluorocarbon masks and subwavelength nanostructures (SWSs) automatically formed on these substrate after the appropriate RIE plasma process. The mechanism of plasma-induced self-masking SWS has been proposed in this paper. Plasma parameter effects on the morphology of SWS have been investigated to achieve perfect nanocone-like SWS for excellent antireflection, including process time, reactive gas, and pressure of the chamber. Optical properties, i.e., antireflection and optical scattering, were simulated by the finite difference time domain (FDTD) method. Calculated data agree well with the experiment results. The optimized SWS show ultrabroadband antireflective property (up to 99% from 500 to 1360 nm). An excellent improvement of transmission was achieved for the deep-ultraviolet (DUV) range. The proposed low-cost, highly efficient, and maskless method was applied to achieve ultrabroadband antireflective and superhydrophilic SWSs on a 100 mm optical window, which promises great potential for applications in the automotive industry, goggles, and optical devices.
X Ray Mask Of Gold-Carbon Mixture Absorber On BCN Compound Substrate Fabricated By Plasma Processes
NASA Astrophysics Data System (ADS)
Aiyer, Chandrasekhar R.; Itoh, Satoshi; Yamada, Hitomi; Morita, Shinzo; Hattori, Shuzo
1988-06-01
X-ray mask fabrication based on BCN compound membrane and gold containing polymeric carbon ( Au-C ) absorber by totally dry processes is proposed. The Au-C films were depo-sited by plasma polymerization of propylene or styrene monomers and co-evaporation of gold. These films have 2 to 5 times higher etching rate than that of pure gold for 09 RIE, depending on the Au content. The stress in the films could be reduced to 1.9 E 7 N/m2 by annealing. The BCN films were deposited on silicon wafers by rf (13.56 MHz) plasma CVD with diborane, methane and nitrogen as source gases at typical deposition rate of 30 nm/min. The optical (633nm) and X ray (Pd L~) transparencies were nearly 80% for film thickness of 6 um. Patterning of Au-C was achieved by using tungsten as intermediate layer and PMMA electron beam resist. CF4 RIE was used to etch the tungsten layer which in turn acted as mask for the gold carbide 02 RIE. The process parameters and the characteristics of the Au-C and BCN films are presented.
NASA Astrophysics Data System (ADS)
Ait-Kaci Ahmed, Ali; Moussine-Pouchkine, Alexis
The study of two of the intermontane molassic basins of the 'Série pourprée de l'Ahnet' shows that they developed independently both in time and space. The characteristics of their thick sedimentary infillings are quite different. The Ouallen basin is filled by essentially fine-grained sediments which were deposited in continental then marine or lacustrine environments; these sediments thicen from east to west. The In Semmen basin is characterised by coarser sediments which were deposited from south to north, in alluvial fan, fluvial, deltaic and slope environments. This basin is also characterised by an episode of carbonate sedimentation leading to the formation of a remarkable thin layer of carbonate, covering the entire sedimentary area, and perhaps related to a volcanic rhyolitic event. The history of the two basins is also marked by obvious tectonic events simultaneous with the sedimentation and related to the recurrent faulting of major Pan-African faults. These led to the formation of very coarse fanglomerates located near the fault scarps, and are probably responsible for the shape and the evolution of the basins.
Reactive ion etching of GaN using BCl 3, BCl 3/Ar and BCl 3/ N 2 gas plasmas
NASA Astrophysics Data System (ADS)
Basak, D.; Nakanishi, T.; Sakai, S.
2000-04-01
Reactive ion etching (RIE) of GaN has been performed using BCl 3 and additives, Ar and N 2, to BCl 3 plasma. The etch rate, surface roughness and the etch profile have been investigated. The etch rate of GaN is found to be 104 nm/min at rf power of 200 W, pressure of 2 Pa, with 9.5 sccm flow rate of BCl 3. The addition of 5 sccm of Ar to 9.5 sccm of BCl 3 reduces the etch rate of GaN while the addition of N 2 does not influence the etch rate significantly. The RIE of GaN layer with BCl 3/Ar and BCl 3/N 2 results in a smoother surface compared to surfaces etched with BCl 3 only. The etched side-wall in BCl 3 plasma makes an angle of 60° with the normal surface, and the angle of inclination is more in cases of BCl 3/Ar and BCl 3/N 2 plasmas. The RIE induced damage to the surface is measured qualitatively by PL measurements. It is observed that the damage to the etched surfaces is similar for all the plasmas.
The effect of reactive ion etch (RIE) process conditions on ReRAM device performance
NASA Astrophysics Data System (ADS)
Beckmann, K.; Holt, J.; Olin-Ammentorp, W.; Alamgir, Z.; Van Nostrand, J.; Cady, N. C.
2017-09-01
The recent surge of research on resistive random access memory (ReRAM) devices has resulted in a wealth of different materials and fabrication approaches. In this work, we describe the performance implications of utilizing a reactive ion etch (RIE) based process to fabricate HfO2 based ReRAM devices, versus a more unconventional shadow mask fabrication approach. The work is the result of an effort to increase device yield and reduce individual device size. Our results show that choice of RIE etch gas (SF6 versus CF4) is critical for defining the post-etch device profile (cross-section), and for tuning the removal of metal layers used as bottom electrodes in the ReRAM device stack. We have shown that etch conditions leading to a tapered profile for the device stack cause poor electrical performance, likely due to metal re-deposition during etching, and damage to the switching layer. These devices exhibit nonlinear I-V during the low resistive state, but this could be improved to linear behavior once a near-vertical etch profile was achieved. Device stacks with vertical etch profiles also showed an increase in forming voltage, reduced switching variability and increased endurance.
Simulation of wave propagation in three-dimensional random media
NASA Technical Reports Server (NTRS)
Coles, William A.; Filice, J. P.; Frehlich, R. G.; Yadlowsky, M.
1993-01-01
Quantitative error analysis for simulation of wave propagation in three dimensional random media assuming narrow angular scattering are presented for the plane wave and spherical wave geometry. This includes the errors resulting from finite grid size, finite simulation dimensions, and the separation of the two-dimensional screens along the propagation direction. Simple error scalings are determined for power-law spectra of the random refractive index of the media. The effects of a finite inner scale are also considered. The spatial spectra of the intensity errors are calculated and compared to the spatial spectra of intensity. The numerical requirements for a simulation of given accuracy are determined for realizations of the field. The numerical requirements for accurate estimation of higher moments of the field are less stringent.
Typpo, Katri V; Tcharmtchi, M Hossein; Thomas, Eric J; Kelly, P Adam; Castillo, Leticia D; Singh, Hardeep
2012-09-01
Resident duty-hour regulations potentially shift the workload from resident to attending physicians. We sought to understand how current or future regulatory changes might impact safety in academic pediatric and neonatal intensive care units. Web-based survey. U.S. academic pediatric and neonatal intensive care units. Attending pediatric and neonatal intensivists. We evaluated perceptions on four intensive care unit safety-related risk measures potentially affected by current duty-hour regulations: 1) attending physician and resident fatigue; 2) attending physician workload; 3) errors (self-reported rates by attending physicians or perceived resident error rates); and 4) safety culture. We also evaluated perceptions of how these risks would change with further duty-hour restrictions. We administered our survey between February and April 2010 to 688 eligible physicians, of whom 360 (52.3%) responded. Most believed that resident error rates were unchanged or worse (91.9%) and safety culture was unchanged or worse (84.4%) with current duty-hour regulations. Of respondents, 61.9% believed their own work-hours providing direct patient care increased and 55.8% believed they were more fatigued while providing direct patient care. Most (85.3%) perceived no increase in their own error rates currently, but in the scenario of further reduction in resident duty-hours, over half (53.3%) believed that safety culture would worsen and a significant proportion (40.3%) believed that their own error rates would increase. Pediatric intensivists do not perceive improved patient safety from current resident duty-hour restrictions. Policies to further restrict resident duty-hours should consider unintended consequences of worsening certain aspects of intensive care unit safety.
NASA Astrophysics Data System (ADS)
Raju, P. V. S.; Potty, Jayaraman; Mohanty, U. C.
2011-09-01
Comprehensive sensitivity analyses on physical parameterization schemes of Weather Research Forecast (WRF-ARW core) model have been carried out for the prediction of track and intensity of tropical cyclones by taking the example of cyclone Nargis, which formed over the Bay of Bengal and hit Myanmar on 02 May 2008, causing widespread damages in terms of human and economic losses. The model performances are also evaluated with different initial conditions of 12 h intervals starting from the cyclogenesis to the near landfall time. The initial and boundary conditions for all the model simulations are drawn from the global operational analysis and forecast products of National Center for Environmental Prediction (NCEP-GFS) available for the public at 1° lon/lat resolution. The results of the sensitivity analyses indicate that a combination of non-local parabolic type exchange coefficient PBL scheme of Yonsei University (YSU), deep and shallow convection scheme with mass flux approach for cumulus parameterization (Kain-Fritsch), and NCEP operational cloud microphysics scheme with diagnostic mixed phase processes (Ferrier), predicts better track and intensity as compared against the Joint Typhoon Warning Center (JTWC) estimates. Further, the final choice of the physical parameterization schemes selected from the above sensitivity experiments is used for model integration with different initial conditions. The results reveal that the cyclone track, intensity and time of landfall are well simulated by the model with an average intensity error of about 8 hPa, maximum wind error of 12 m s-1and track error of 77 km. The simulations also show that the landfall time error and intensity error are decreasing with delayed initial condition, suggesting that the model forecast is more dependable when the cyclone approaches the coast. The distribution and intensity of rainfall are also well simulated by the model and comparable with the TRMM estimates.
Clinical review: Medication errors in critical care
Moyen, Eric; Camiré, Eric; Stelfox, Henry Thomas
2008-01-01
Medication errors in critical care are frequent, serious, and predictable. Critically ill patients are prescribed twice as many medications as patients outside of the intensive care unit (ICU) and nearly all will suffer a potentially life-threatening error at some point during their stay. The aim of this article is to provide a basic review of medication errors in the ICU, identify risk factors for medication errors, and suggest strategies to prevent errors and manage their consequences. PMID:18373883
Quantitative evaluation of statistical errors in small-angle X-ray scattering measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sedlak, Steffen M.; Bruetzel, Linda K.; Lipfert, Jan
A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ 2(q) = [I(q) + const.]/(kq), whereI(q) is the scattering intensity as a function of the momentum transferq;kand const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurementmore » errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.« less
In-hospital fellow coverage reduces communication errors in the surgical intensive care unit.
Williams, Mallory; Alban, Rodrigo F; Hardy, James P; Oxman, David A; Garcia, Edward R; Hevelone, Nathanael; Frendl, Gyorgy; Rogers, Selwyn O
2014-06-01
Staff coverage strategies of intensive care units (ICUs) impact clinical outcomes. High-intensity staff coverage strategies are associated with lower morbidity and mortality. Accessible clinical expertise, team work, and effective communication have all been attributed to the success of this coverage strategy. We evaluate the impact of in-hospital fellow coverage (IHFC) on improving communication of cardiorespiratory events. A prospective observational study performed in an academic tertiary care center with high-intensity staff coverage. The main outcome measure was resident to fellow communication of cardiorespiratory events during IHFC vs home coverage (HC) periods. Three hundred twelve cardiorespiratory events were collected in 114 surgical ICU patients in 134 study days. Complete data were available for 306 events. One hundred three communication errors occurred. IHFC was associated with significantly better communication of events compared to HC (P<.0001). Residents communicated 89% of events during IHFC vs 51% of events during HC (P<.001). Communication patterns of junior and midlevel residents were similar. Midlevel residents communicated 68% of all on-call events (87% IHFC vs 50% HC, P<.001). Junior residents communicated 66% of events (94% IHFC vs 52% HC, P<.001). Communication errors were lower in all ICUs during IHFC (P<.001). IHFC reduced communication errors. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miyasaka, Y; Kadoya, N; Ito, K
Purpose: Accurate deformable image registration (DIR) between external beam radiotherapy (EBRT) and HDR brachytherapy (BT) CT images in cervical cancer is challenging. DSC has been evaluated only on the basis of the consistency of the structure, and its use does not guarantee an anatomically reasonable deformation. We evaluate the DIR accuracy for cervical cancer with DSC and anatomical landmarks using a 3D-printed pelvis phantom. Methods: A 3D-printed, deformable female pelvis phantom was created on the basis of the patient’s CT image. Urethane and silicon were used as materials for creating the uterus and bladder, respectively, in the phantom. We performedmore » DIR in two cases: case-A with a full bladder (170 ml) in both the EBRT and BT images and case-B with a full bladder in the BT image and a half bladder (100 ml) in the EBRT image. DIR was evaluated using DSCs and 70 uterus and bladder landmarks. A Hybrid intensity and structure DIR algorithm with two settings (RayStation) was used. Results: In the case-A, DSCs of the intensity-based DIR were 0.93 and 0.85 for the bladder and uterus, respectively, whereas those of hybrid-DIR were 0.98 and 0.96, respectively. The mean landmark error values of intensity-based DIR were 0.73±0.29 and 1.70±0.19 cm for the bladder and uterus, respectively, whereas those of Hybrid-DIR were 0.43±0.33 and 1.23±0.25 cm, respectively. In both cases, the Hybrid-DIR accuracy was better than the intensity-based DIR accuracy for both evaluation methods. However, for several bladder landmarks, the Hybrid-DIR landmark errors were larger than the corresponding intensity-based DIR errors (e.g., 2.26 vs 1.25 cm). Conclusion: Our results demonstrate that Hybrid-DIR can perform with a better accuracy than the intensity-based DIR for both DSC and landmark errors; however, Hybrid-DIR shows a larger landmark error for some landmarks because the technique focuses on both the structure and intensity.« less
Zhang, Ji-Li; Liu, Bo-Fei; Chu, Teng-Fei; Di, Xue-Ying; Jin, Sen
2012-06-01
A laboratory burning experiment was conducted to measure the fire spread speed, residual time, reaction intensity, fireline intensity, and flame length of the ground surface fuels collected from a Korean pine (Pinus koraiensis) and Mongolian oak (Quercus mongolica) mixed stand in Maoer Mountains of Northeast China under the conditions of no wind, zero slope, and different moisture content, load, and mixture ratio of the fuels. The results measured were compared with those predicted by the extended Rothermel model to test the performance of the model, especially for the effects of two different weighting methods on the fire behavior modeling of the mixed fuels. With the prediction of the model, the mean absolute errors of the fire spread speed and reaction intensity of the fuels were 0.04 m X min(-1) and 77 kW X m(-2), their mean relative errors were 16% and 22%, while the mean absolute errors of residual time, fireline intensity and flame length were 15.5 s, 17.3 kW X m(-1), and 9.7 cm, and their mean relative errors were 55.5%, 48.7%, and 24%, respectively, indicating that the predicted values of residual time, fireline intensity, and flame length were lower than the observed ones. These errors could be regarded as the lower limits for the application of the extended Rothermel model in predicting the fire behavior of similar fuel types, and provide valuable information for using the model to predict the fire behavior under the similar field conditions. As a whole, the two different weighting methods did not show significant difference in predicting the fire behavior of the mixed fuels by extended Rothermel model. When the proportion of Korean pine fuels was lower, the predicted values of spread speed and reaction intensity obtained by surface area weighting method and those of fireline intensity and flame length obtained by load weighting method were higher; when the proportion of Korean pine needles was higher, the contrary results were obtained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saleh, Ahmed A., E-mail: asaleh@uow.edu.au
Even with the use of X-ray polycapillary lenses, sample tilting during pole figure measurement results in a decrease in the recorded X-ray intensity. The magnitude of this error is affected by the sample size and/or the finite detector size. These errors can be typically corrected by measuring the intensity loss as a function of the tilt angle using a texture-free reference sample (ideally made of the same alloy as the investigated material). Since texture-free reference samples are not readily available for all alloys, the present study employs an empirical procedure to estimate the correction curve for a particular experimental configuration.more » It involves the use of real texture-free reference samples that pre-exist in any X-ray diffraction laboratory to first establish the empirical correlations between X-ray intensity, sample tilt and their Bragg angles and thereafter generate correction curves for any Bragg angle. It will be shown that the empirically corrected textures are in very good agreement with the experimentally corrected ones. - Highlights: •Sample tilting during X-ray pole figure measurement leads to intensity loss errors. •Texture-free reference samples are typically used to correct the pole figures. •An empirical correction procedure is proposed in the absence of reference samples. •The procedure relies on reference samples that pre-exist in any texture laboratory. •Experimentally and empirically corrected textures are in very good agreement.« less
Chedoe, Indra; Molendijk, Harry; Hospes, Wobbe; Van den Heuvel, Edwin R; Taxis, Katja
2012-11-01
To examine the effect of a multifaceted educational intervention on the incidence of medication preparation and administration errors in a neonatal intensive care unit (NICU). Prospective study with a preintervention and postintervention measurement using direct observation. NICU in a tertiary hospital in the Netherlands. A multifaceted educational intervention including teaching and self-study. The incidence of medication preparation and administration errors. Clinical importance was assessed by three experts. The incidence of errors decreased from 49% (43-54%) (151 medications with one or more errors of 311 observations) to 31% (87 of 284) (25-36%). Preintervention, 0.3% (0-2%) medications contained severe errors, 26% (21-31%) moderate and 23% (18-28%) minor errors; postintervention, none 0% (0-2%) was severe, 23% (18-28%) moderate and 8% (5-12%) minor. A generalised estimating equations analysis provided an OR of 0.49 (0.29-0.84) for period (p=0.032), (route of administration (p=0.001), observer within period (p=0.036)). The multifaceted educational intervention seemed to have contributed to a significant reduction of the preparation and administration error rate, but other measures are needed to improve medication safety further.
Random errors in interferometry with the least-squares method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Qi
2011-01-20
This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Sen; Li, Guangjun; Wang, Maojie
The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors weremore » 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.« less
Booth, Rachelle; Sturgess, Emma; Taberner-Stokes, Alison; Peters, Mark
2012-11-01
To establish the baseline prescribing error rate in a tertiary paediatric intensive care unit (PICU) and to determine the impact of a zero tolerance prescribing (ZTP) policy incorporating a dedicated prescribing area and daily feedback of prescribing errors. A prospective, non-blinded, observational study was undertaken in a 12-bed tertiary PICU over a period of 134 weeks. Baseline prescribing error data were collected on weekdays for all patients for a period of 32 weeks, following which the ZTP policy was introduced. Daily error feedback was introduced after a further 12 months. Errors were sub-classified as 'clinical', 'non-clinical' and 'infusion prescription' errors and the effects of interventions considered separately. The baseline combined prescribing error rate was 892 (95 % confidence interval (CI) 765-1,019) errors per 1,000 PICU occupied bed days (OBDs), comprising 25.6 % clinical, 44 % non-clinical and 30.4 % infusion prescription errors. The combined interventions of ZTP plus daily error feedback were associated with a reduction in the combined prescribing error rate to 447 (95 % CI 389-504) errors per 1,000 OBDs (p < 0.0001), an absolute risk reduction of 44.5 % (95 % CI 40.8-48.0 %). Introduction of the ZTP policy was associated with a significant decrease in clinical and infusion prescription errors, while the introduction of daily error feedback was associated with a significant reduction in non-clinical prescribing errors. The combined interventions of ZTP and daily error feedback were associated with a significant reduction in prescribing errors in the PICU, in line with Department of Health requirements of a 40 % reduction within 5 years.
NASA Technical Reports Server (NTRS)
Bollinger, D.
1983-01-01
The production dry etch processes are reviewed from the perspective of microelectronic fabrication applications. The major dry etch processes used in the fabrication of microelectronic devices can be divided into two categories - plasma processes in which samples are directly exposed to an electrical discharge, and ion beam processes in which samples are etched by a beam of ions extracted from a discharge. The plasma etch processes can be distinguished by the degree to which ion bombardment contributes to the etch process. This, in turn is related to capability for anisotropic etching. Reactive Ion Etching (RIE) and Ion Beam Etching are of most interest for etching of thin film metals. RIE is generally considered the best process for large volume, anisotropic aluminum etching.
2015-01-01
RTO ou AGARD doivent comporter la dénomination « STO », « RTO » ou « AGARD » selon le cas, suivi du numéro de série. Des informations analogues...rapports de la STO au fur et à mesure de leur publication, vous pouvez consulter notre site Web (http://www.sto.nato.int/) et vous abonner à ce service...le cas, suivie du numéro de série (par exemple AGARD-AG-315). Des informations analogues, telles que le titre et la date de publication sont
Lohmann, W
1978-01-01
The shape of the survivorship curve can easily be interpreted on condition that the probability of death is proportional to an exponentially rising function of ageing. According to the formation of a sum for determining of the age index by Ries it was investigated to what extent the survivorship curve may be approximated by a sum of exponentials. It follows that the difference between the pure exponential function and a sum of exponentials by using possible values is lying within the random variation. Because the probability of death for different diseases is variable, the new statement is a better one.
NASA Technical Reports Server (NTRS)
Bringemeier, D.
1992-01-01
Research undertaken in the last decades in Noerdlinger Ries, Germany, has repeatedly emphasized the sharp contact between Bunte breccia and suevite. However, extensive investigations into this layer boundary have not yet been possible due to insufficient outcrop ratios. New outcrops enabled an in-depth investigation into the superposition of suevite on the Bunte breccia, which is assigned a key role in interpreting the transport mechanisms of ejecta of large impact. In two quarries lying several kilometers east and south-southwest of the crater, the contact between the suevite and Bunte breccia was recorded in detailed sections on outcrops of over 50 m in length.
NASA: Model development for human factors interfacing
NASA Technical Reports Server (NTRS)
Smith, L. L.
1984-01-01
The results of an intensive literature review in the general topics of human error analysis, stress and job performance, and accident and safety analysis revealed no usable techniques or approaches for analyzing human error in ground or space operations tasks. A task review model is described and proposed to be developed in order to reduce the degree of labor intensiveness in ground and space operations tasks. An extensive number of annotated references are provided.
NASA Astrophysics Data System (ADS)
Ito, Shunya; Sato, Hiroki; Tasaki, Yuhei; Watanuki, Kimihito; Nemoto, Nobukatsu; Nakagawa, Masaru
2016-06-01
We investigated the selection of bis(trimethylsilyl)phenyl-containing (meth)acrylates as additives to improve the durability to oxygen reactive ion etching (O2 RIE) of sub-50 nm imprint resist patterns suitable for bubble-defect-free UV nanoimprinting with a readily condensable gas. 2,5-Bis(2-acryloyloxyethoxy)-1,4-bis(trimethylsilyl)benzene, which has a diacrylate chemical structure similar to that of glycerol 1,3-diglycerolate diacrylate used as a base monomer, and 3-(2-methacryloyloxyethoxy)-1-(hydroxylethoxy)-2-propoxy-3,5-bis(trimethylsilyl)benzene, which has a hydroxy group similar to the base monomer, were synthesized taking into consideration the Ohnishi and ring parameters, and the oxidization of the trimethylsilyl moiety to inorganic species during O2 RIE. The addition of the latter liquid additive to the base monomer decreased etching rate owing to the good miscibility of the additive in the base monomer, while the addition of the former crystalline additive caused phase separation after UV nanoimprinting. The latter additive worked as a compatibilizer to the former additive, which is preferred for etching durability improvement. The coexistence of the additives enabled the fabrication of a 45 nm line-and-space resist pattern by UV nanoimprinting, and its residual layer could be removed by O2 RIE.
Lee, Sang Bong; Lee, Ho Won; Singh, Thoudam Debraj; Li, Yinghua; Kim, Sang Kyoon; Cho, Sung Jin; Lee, Sang-Woo; Jeong, Shin Young; Ahn, Byeong-Cheol; Choi, Sangil; Lee, In-Kyu; Lim, Dong-Kwon; Lee, Jaetae; Jeon, Yong Hyun
2017-01-01
Reliable and sensitive imaging tools are required to track macrophage migration and provide a better understating of their biological roles in various diseases. Here, we demonstrate the possibility of radioactive iodide-embedded gold nanoparticles (RIe-AuNPs) as a cell tracker for nuclear medicine imaging. To demonstrate this utility, we monitored macrophage migration to carrageenan-induced sites of acute inflammation in living subjects and visualized the effects of anti-inflammatory agents on this process. Macrophage labeling with RIe-AuNPs did not alter their biological functions such as cell proliferation, phenotype marker expression, or phagocytic activity. In vivo imaging with positron-emission tomography revealed the migration of labeled macrophages to carrageenan-induced inflammation lesions 3 h after transfer, with highest recruitment at 6 h and a slight decline of radioactive signal at 24 h; these findings were highly consistent with the data of a bio-distribution study. Treatment with dexamethasone (an anti-inflammation drug) or GSK5182 (an ERRγ inverse agonist) hindered macrophage recruitment to the inflamed sites. Our findings suggest that a cell tracking strategy utilizing RIe-AuNPs will likely be highly useful in research related to macrophage-related disease and cell-based therapies. PMID:28382164
Optimal design and fabrication of ring resonator composed of Ge02-doped silica waveguides for IOG
NASA Astrophysics Data System (ADS)
Guo, Lijun; Shi, Bangren; Chen, Chen; Lv, Hao; Zhao, Zhenming; Zhao, Meng
2009-07-01
The ring resonator is the core sensing element in the resonant integration optical gyroscope (IOG) . Its performances influence the minimum resolution and the error items of gyroscope directly and it is the key of the design and manufacturing. This paper presents optimal design of ring resonator composed of Ge02 -doped silica waveguides fabricated on silicon substrates using wide angle beam propagation method (WA-BPM). The characteristic of the light propagating across the ring resonator is analyzed. According to the design results, we succeed in fabricating the ring resonator by Plasma Enhanced Chemical Vapor Deposition (PECVD) method and Reactive Ion Etching (RIE) technology. In order to characterize the ring resonator, an optical measurement setup is built, fiber laser line-width is 50 kHz, detector responsibility is 0.95A/W and integral time is 10s. By testing, propagation loss and total loss of ring resonator are 0.02dB/cm and 0.1dB/circuit respectively. Observed from the resonance curve, a finesse of 12.5.
Underestimation of Low-Dose Radiation in Treatment Planning of Intensity-Modulated Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jang, Si Young; Liu, H. Helen; Mohan, Radhe
2008-08-01
Purpose: To investigate potential dose calculation errors in the low-dose regions and identify causes of such errors for intensity-modulated radiotherapy (IMRT). Methods and Materials: The IMRT treatment plans of 23 patients with lung cancer and mesothelioma were reviewed. Of these patients, 15 had severe pulmonary complications after radiotherapy. Two commercial treatment-planning systems (TPSs) and a Monte Carlo system were used to calculate and compare dose distributions and dose-volume parameters of the target volumes and critical structures. The effect of tissue heterogeneity, multileaf collimator (MLC) modeling, beam modeling, and other factors that could contribute to the differences in IMRT dose calculationsmore » were analyzed. Results: In the commercial TPS-generated IMRT plans, dose calculation errors primarily occurred in the low-dose regions of IMRT plans (<50% of the radiation dose prescribed for the tumor). Although errors in the dose-volume histograms of the normal lung were small (<5%) above 10 Gy, underestimation of dose <10 Gy was found to be up to 25% in patients with mesothelioma or large target volumes. These errors were found to be caused by inadequate modeling of MLC transmission and leaf scatter in commercial TPSs. The degree of low-dose errors depends on the target volumes and the degree of intensity modulation. Conclusions: Secondary radiation from MLCs contributes a significant portion of low dose in IMRT plans. Dose underestimation could occur in conventional IMRT dose calculations if such low-dose radiation is not properly accounted for.« less
Analysis of deformable image registration accuracy using computational modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong Hualiang; Kim, Jinkoo; Chetty, Indrin J.
2010-03-15
Computer aided modeling of anatomic deformation, allowing various techniques and protocols in radiation therapy to be systematically verified and studied, has become increasingly attractive. In this study the potential issues in deformable image registration (DIR) were analyzed based on two numerical phantoms: One, a synthesized, low intensity gradient prostate image, and the other a lung patient's CT image data set. Each phantom was modeled with region-specific material parameters with its deformation solved using a finite element method. The resultant displacements were used to construct a benchmark to quantify the displacement errors of the Demons and B-Spline-based registrations. The results showmore » that the accuracy of these registration algorithms depends on the chosen parameters, the selection of which is closely associated with the intensity gradients of the underlying images. For the Demons algorithm, both single resolution (SR) and multiresolution (MR) registrations required approximately 300 iterations to reach an accuracy of 1.4 mm mean error in the lung patient's CT image (and 0.7 mm mean error averaged in the lung only). For the low gradient prostate phantom, these algorithms (both SR and MR) required at least 1600 iterations to reduce their mean errors to 2 mm. For the B-Spline algorithms, best performance (mean errors of 1.9 mm for SR and 1.6 mm for MR, respectively) on the low gradient prostate was achieved using five grid nodes in each direction. Adding more grid nodes resulted in larger errors. For the lung patient's CT data set, the B-Spline registrations required ten grid nodes in each direction for highest accuracy (1.4 mm for SR and 1.5 mm for MR). The numbers of iterations or grid nodes required for optimal registrations depended on the intensity gradients of the underlying images. In summary, the performance of the Demons and B-Spline registrations have been quantitatively evaluated using numerical phantoms. The results show that parameter selection for optimal accuracy is closely related to the intensity gradients of the underlying images. Also, the result that the DIR algorithms produce much lower errors in heterogeneous lung regions relative to homogeneous (low intensity gradient) regions, suggests that feature-based evaluation of deformable image registration accuracy must be viewed cautiously.« less
Patient Safety in the Context of Neonatal Intensive Care: Research and Educational Opportunities
Raju, Tonse N. K.; Suresh, Gautham; Higgins, Rosemary D.
2012-01-01
Case reports and observational studies continue to report adverse events from medical errors. However, despite considerable attention to patient safety in the popular media, this topic is not a regular component of medical education, and much research needs to be carried out to understand the causes, consequences, and prevention of healthcare-related adverse events during neonatal intensive care. To address the knowledge gaps and to formulate a research and educational agenda in neonatology, the Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) invited a panel of experts to a workshop in August 2010. Patient safety issues discussed were: the reasons for errors, including systems design, working conditions, and worker fatigue; a need to develop a “culture” of patient safety; the role of electronic medical records, information technology, and simulators in reducing errors; error disclosure practices; medico-legal concerns; and educational needs. Specific neonatology-related topics discussed were: errors during resuscitation, mechanical ventilation, and performance of invasive procedures; medication errors including those associated with milk feedings; diagnostic errors; and misidentification of patients. This article provides an executive summary of the workshop. PMID:21386749
Paediatric in-patient prescribing errors in Malaysia: a cross-sectional multicentre study.
Khoo, Teik Beng; Tan, Jing Wen; Ng, Hoong Phak; Choo, Chong Ming; Bt Abdul Shukor, Intan Nor Chahaya; Teh, Siao Hean
2017-06-01
Background There is a lack of large comprehensive studies in developing countries on paediatric in-patient prescribing errors in different settings. Objectives To determine the characteristics of in-patient prescribing errors among paediatric patients. Setting General paediatric wards, neonatal intensive care units and paediatric intensive care units in government hospitals in Malaysia. Methods This is a cross-sectional multicentre study involving 17 participating hospitals. Drug charts were reviewed in each ward to identify the prescribing errors. All prescribing errors identified were further assessed for their potential clinical consequences, likely causes and contributing factors. Main outcome measures Incidence, types, potential clinical consequences, causes and contributing factors of the prescribing errors. Results The overall prescribing error rate was 9.2% out of 17,889 prescribed medications. There was no significant difference in the prescribing error rates between different types of hospitals or wards. The use of electronic prescribing had a higher prescribing error rate than manual prescribing (16.9 vs 8.2%, p < 0.05). Twenty eight (1.7%) prescribing errors were deemed to have serious potential clinical consequences and 2 (0.1%) were judged to be potentially fatal. Most of the errors were attributed to human factors, i.e. performance or knowledge deficit. The most common contributing factors were due to lack of supervision or of knowledge. Conclusions Although electronic prescribing may potentially improve safety, it may conversely cause prescribing errors due to suboptimal interfaces and cumbersome work processes. Junior doctors need specific training in paediatric prescribing and close supervision to reduce prescribing errors in paediatric in-patients.
Effects of dry etching processes on exciton and polariton characteristics in ZnTe
NASA Astrophysics Data System (ADS)
Sun, J. H.; Xie, W. B.; Shen, W. Z.; Ogawa, H.; Guo, Q. X.
2003-12-01
We have employed temperature-dependent reflection spectra to study the effects of reactive ion etching (RIE) on the exciton and polariton characteristics in ZnTe crystals exposed to CH4/H2 gases under different rf plasma powers. Classic exciton-polariton theory has been used to calculate the reflection spectra. By comparing with an as-grown ZnTe crystal and the temperature-dependent behavior, we are able to identify the excitons and RIE-induced polariton structures in these dry etched ZnTe crystals. An increase of the rf plasma power will lead to an increase of defect density in the surface damage layers, resulting in a decrease of the photon energies of the observed exciton and polariton structures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai Jing; Read, Paul W.; Baisden, Joseph M.
Purpose: To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Methods and Materials: Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA)more » from RedCAM ({epsilon}), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability ({nu}). Results: Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies ({epsilon} = -21.64% {+-} 8.23%) and lung tumor patient studies ({epsilon} = -20.31% {+-} 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly ({epsilon} = -5.13{nu} - 6.71, r{sup 2} = 0.76) with the subjects' respiratory variability. Conclusions: Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.« less
Cai, Jing; Read, Paul W; Baisden, Joseph M; Larner, James M; Benedict, Stanley H; Sheng, Ke
2007-11-01
To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA) from RedCAM (epsilon), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability (nu). Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies (epsilon = -21.64% +/- 8.23%) and lung tumor patient studies (epsilon = -20.31% +/- 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly (epsilon = -5.13nu - 6.71, r(2) = 0.76) with the subjects' respiratory variability. Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.
A study on suppressing transmittance fluctuations for air-gapped Glan-type polarizing prisms
NASA Astrophysics Data System (ADS)
Zhang, Chuanfa; Li, Dailin; Zhu, Huafeng; Li, Chuanzhi; Jiao, Zhiyong; Wang, Ning; Xu, Zhaopeng; Wang, Xiumin; Song, Lianke
2018-05-01
Light intensity transmittance is a key parameter for the design of polarizing prisms, while sometimes its experimental curves based on spatial incident angle presents periodical fluctuations. Here, we propose a novel method for completely suppressing these fluctuations via setting a glued error angle in the air gap of Glan-Taylor prisms. The proposal consists of: an accurate formula of the intensity transmittance for Glan-Taylor prisms, a numerical simulation and a contrast experiment of Glan-Taylor prisms for analyzing the causes of the fluctuations, and a simple method for accurately measuring the glued error angle. The result indicates that when the setting glued error angle is larger than the critical angle for a certain polarizing prism, the fluctuations can be completely suppressed, and a smooth intensity transmittance curve can be obtained. Besides, the critical angle in the air gap for suppressing the fluctuations is decreased with the increase of beam spot size. This method has the advantage of having less demand for the prism position in optical systems.
CPO Prediction: Accuracy Assessment and Impact on UT1 Intensive Results
NASA Technical Reports Server (NTRS)
Malkin, Zinovy
2010-01-01
The UT1 Intensive results heavily depend on the celestial pole offset (CPO) model used during data processing. Since accurate CPO values are available with a delay of two to four weeks, CPO predictions are necessarily applied to the UT1 Intensive data analysis, and errors in the predictions can influence the operational UT1 accuracy. In this paper we assess the real accuracy of CPO prediction using the actual IERS and PUL predictions made in 2007-2009. Also, results of operational processing were analyzed to investigate the actual impact of EOP prediction errors on the rapid UT1 results. It was found that the impact of CPO prediction errors is at a level of several microseconds, whereas the impact of the inaccuracy in the polar motion prediction may be about one order of magnitude larger for ultra-rapid UT1 results. The situation can be amended if the IERS Rapid solution will be updated more frequently.
Mutual optical intensity propagation through non-ideal mirrors
Meng, Xiangyu; Shi, Xianbo; Wang, Yong; ...
2017-08-18
The mutual optical intensity (MOI) model is extended to include the propagation of partially coherent radiation through non-ideal mirrors. The propagation of the MOI from the incident to the exit plane of the mirror is realised by local ray tracing. The effects of figure errors can be expressed as phase shifts obtained by either the phase projection approach or the direct path length method. Using the MOI model, the effects of figure errors are studied for diffraction-limited cases using elliptical cylinder mirrors. Figure errors with low spatial frequencies can vary the intensity distribution, redistribute the local coherence function and distortmore » the wavefront, but have no effect on the global degree of coherence. The MOI model is benchmarked againstHYBRIDand the multi-electronSynchrotron Radiation Workshop(SRW) code. The results show that the MOI model gives accurate results under different coherence conditions of the beam. Other than intensity profiles, the MOI model can also provide the wavefront and the local coherence function at any location along the beamline. The capability of tuning the trade-off between accuracy and efficiency makes the MOI model an ideal tool for beamline design and optimization.« less
NASA Astrophysics Data System (ADS)
Zhou, Feifan; Yamaguchi, Munehiko; Qin, Xiaohao
2016-07-01
This paper investigates the possible sources of errors associated with tropical cyclone (TC) tracks forecasted using the Global/Regional Assimilation and Prediction System (GRAPES). The GRAPES forecasts were made for 16 landfalling TCs in the western North Pacific basin during the 2008 and 2009 seasons, with a forecast length of 72 hours, and using the default initial conditions ("initials", hereafter), which are from the NCEP-FNL dataset, as well as ECMWF initials. The forecasts are compared with ECMWF forecasts. The results show that in most TCs, the GRAPES forecasts are improved when using the ECMWF initials compared with the default initials. Compared with the ECMWF initials, the default initials produce lower intensity TCs and a lower intensity subtropical high, but a higher intensity South Asia high and monsoon trough, as well as a higher temperature but lower specific humidity at the TC center. Replacement of the geopotential height and wind fields with the ECMWF initials in and around the TC center at the initial time was found to be the most efficient way to improve the forecasts. In addition, TCs that showed the greatest improvement in forecast accuracy usually had the largest initial uncertainties in TC intensity and were usually in the intensifying phase. The results demonstrate the importance of the initial intensity for TC track forecasts made using GRAPES, and indicate the model is better in describing the intensifying phase than the decaying phase of TCs. Finally, the limit of the improvement indicates that the model error associated with GRAPES forecasts may be the main cause of poor forecasts of landfalling TCs. Thus, further examinations of the model errors are required.
A Study of Upper Error Limits in Accounting Populations.
1986-09-01
The error amount intensity is a population characteristic obtained by dividing the total...423.36/$763,931.19). This population characteristic is of interest because the results of the simulation done for research questions four through v.o
NASA Astrophysics Data System (ADS)
Fu, Qingshan; Xue, Yongqiang; Cui, Zixiang; Duan, Huijuan
2017-07-01
A rational melting model is indispensable to address the fundamental issue regarding the melting of nanoparticles. To ascertain the rationality and the application scopes of the three classical thermodynamic models, namely Pawlow, Rie, and Reiss melting models, corresponding accurate equations for size-dependent melting temperature of nanoparticles were derived. Comparison of the melting temperatures of Au, Al, and Sn nanoparticles calculated by the accurate equations with available experimental results demonstrates that both Reiss and Rie melting models are rational and capable of accurately describing the melting behaviors of nanoparticles at different melting stages. The former (surface pre-melting) is applicable to the stage from initial melting to critical thickness of liquid shell, while the latter (solid particles surrounded by a great deal of liquid) from the critical thickness to complete melting. The melting temperatures calculated by the accurate equation based on Reiss melting model are in good agreement with experimental results within the whole size range of calculation compared with those by other theoretical models. In addition, the critical thickness of liquid shell is found to decrease with particle size decreasing and presents a linear variation with particle size. The accurate thermodynamic equations based on Reiss and Rie melting models enable us to quantitatively and conveniently predict and explain the melting behaviors of nanoparticles at all size range in the whole melting process. [Figure not available: see fulltext.
Baquedano, Estela; Martinez, Ramses V; Llorens, José M; Postigo, Pablo A
2017-05-11
Soft lithography allows for the simple and low-cost fabrication of nanopatterns with different shapes and sizes over large areas. However, the resolution and the aspect ratio of the nanostructures fabricated by soft lithography are limited by the depth and the physical properties of the stamp. In this work, silicon nanobelts and nanostructures were achieved by combining soft nanolithography patterning with optimized reactive ion etching (RIE) in silicon. Using polymethylmethacrylate (PMMA) nanopatterned layers with thicknesses ranging between 14 and 50 nm, we obtained silicon nanobelts in areas of square centimeters with aspect ratios up to ~1.6 and linewidths of 225 nm. The soft lithographic process was assisted by a thin film of SiO x (less than 15 nm) used as a hard mask and RIE. This simple patterning method was also used to fabricate 2D nanostructures (nanopillars) with aspect ratios of ~2.7 and diameters of ~200 nm. We demonstrate that large areas patterned with silicon nanobelts exhibit a high reflectivity peak in the ultraviolet C (UVC) spectral region (280 nm) where some aminoacids and peptides have a strong absorption. We also demonstrated how to tailor the aspect ratio and the wettability of these photonic surfaces (contact angles ranging from 8.1 to 96.2°) by changing the RIE power applied during the fabrication process.
Microfabricated Nanotopological Surfaces for Study of Adhesion-dependent Cell mechanosensitivity**
Chen, Weiqiang; Sun, Yubing
2014-01-01
Cells display high sensitivity and exhibit diverse responses to the intrinsic nanotopography of the extracellular matrix through their nanoscale cellular sensing machinery. Here, we reported a simple microfabrication method for precise control and spatial patterning of the local nanoroughness on glass surfaces using photolithography and reactive ion etching (RIE). Using RIE-generated nanorough glass surfaces, we demonstrated that local nanoroughness could provide a potent biophysical signal to regulate a diverse array of NIH/3T3 fibroblast behaviors, including cell morphology, adhesion, proliferation and migration. We further showed that cellular responses to nanotopography might be regulated by cell adhesion signaling and actin cytoskeleton remodeling. To further investigate the role of cytoskeleton contractility in nanoroughness sensing, we applied the RIE method to generate nanoroughness on the tops of an array of elastomeric poly-dimethylsiloxane (PDMS) microposts. We utilized the PDMS microposts as force sensors and demonstrated that nanoroughness could indeed regulate the cytoskeleton contractility of NIH/3T3 fibroblasts. Our results suggested that a feedback regulation and mechano-chemical integration mechanism involving adhesion signaling, actin cytoskeleton, and intracellular mechanosensory components might play an important role in regulating mechanosensitive behaviors of NIH/3T3 fibroblasts. The capability to control and further predict cellular responses to nanoroughness might suggest novel methods for developing biomaterials mimicking nanotopographic structures in vivo and suitable local cellular microenvironments for functional tissue engineering. PMID:22887768
NASA Technical Reports Server (NTRS)
Brown, G. S.; Curry, W. J.
1977-01-01
The statistical error of the pointing angle estimation technique is determined as a function of the effective receiver signal to noise ratio. Other sources of error are addressed and evaluated with inadequate calibration being of major concern. The impact of pointing error on the computation of normalized surface scattering cross section (sigma) from radar and the waveform attitude induced altitude bias is considered and quantitative results are presented. Pointing angle and sigma processing algorithms are presented along with some initial data. The intensive mode clean vs. clutter AGC calibration problem is analytically resolved. The use clutter AGC data in the intensive mode is confirmed as the correct calibration set for the sigma computations.
Systematic error of diode thermometer.
Iskrenovic, Predrag S
2009-08-01
Semiconductor diodes are often used for measuring temperatures. The forward voltage across a diode decreases, approximately linearly, with the increase in temperature. The applied method is mainly the simplest one. A constant direct current flows through the diode, and voltage is measured at diode terminals. The direct current that flows through the diode, putting it into operating mode, heats up the diode. The increase in temperature of the diode-sensor, i.e., the systematic error due to self-heating, depends on the intensity of current predominantly and also on other factors. The results of systematic error measurements due to heating up by the forward-bias current have been presented in this paper. The measurements were made at several diodes over a wide range of bias current intensity.
System calibration method for Fourier ptychographic microscopy
NASA Astrophysics Data System (ADS)
Pan, An; Zhang, Yan; Zhao, Tianyu; Wang, Zhaojun; Dan, Dan; Lei, Ming; Yao, Baoli
2017-09-01
Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging technique with both high-resolution and wide field of view. In current FPM imaging platforms, systematic error sources come from aberrations, light-emitting diode (LED) intensity fluctuation, parameter imperfections, and noise, all of which may severely corrupt the reconstruction results with similar artifacts. Therefore, it would be unlikely to distinguish the dominating error from these degraded reconstructions without any preknowledge. In addition, systematic error is generally a mixture of various error sources in the real situation, and it cannot be separated due to their mutual restriction and conversion. To this end, we report a system calibration procedure, termed SC-FPM, to calibrate the mixed systematic errors simultaneously from an overall perspective, based on the simulated annealing algorithm, the LED intensity correction method, the nonlinear regression process, and the adaptive step-size strategy, which involves the evaluation of an error metric at each iteration step, followed by the re-estimation of accurate parameters. The performance achieved both in simulations and experiments demonstrates that the proposed method outperforms other state-of-the-art algorithms. The reported system calibration scheme improves the robustness of FPM, relaxes the experiment conditions, and does not require any preknowledge, which makes the FPM more pragmatic.
Nature of nursing errors and their contributing factors in intensive care units.
Eltaybani, Sameh; Mohamed, Nadia; Abdelwareth, Mona
2018-04-27
Errors tend to be multifactorial and so learning from nurses' experiences with them would be a powerful tool toward promoting patient safety. To identify the nature of nursing errors and their contributing factors in intensive care units (ICUs). A semi-structured interview with 112 critical care nurses to elicit the reports about their encountered errors followed by a content analysis. A total of 300 errors were reported. Most of them (94·3%) were classified in more than one error category, e.g. 'lack of intervention', 'lack of attentiveness' and 'documentation errors': these were the most frequently involved error categories. Approximately 40% of reported errors contributed to significant harm or death of the involved patients, with system-related factors being involved in 84·3% of them. More errors occur during the evening shift than the night and morning shifts (42·7% versus 28·7% and 16·7%, respectively). There is a statistically significant relation (p ≤ 0·001) between error disclosure to a nursing supervisor and its impact on the patient. Nurses are more likely to report their errors when they feel safe and when the reporting system is not burdensome, although an internationally standardized language to define and analyse nursing errors is needed. Improving the health care system, particularly the managerial and environmental aspects, might reduce nursing errors in ICUs in terms of their incidence and seriousness. Targeting error-liable times in the ICU, such as mid-evening and mid-night shifts, along with improved supervision and adequate staff reallocation, might tackle the incidence and seriousness of nursing errors. Development of individualized nursing interventions for patients with low health literacy and patients in isolation might create more meaningful dialogue for ICU health care safety. © 2018 British Association of Critical Care Nurses.
Nanogrids and Beehive-Like Nanostructures Formed by Plasma Etching the Self-Organized SiGe Islands
NASA Astrophysics Data System (ADS)
Chang, Yuan-Ming; Jian, Sheng-Rui; Juang, Jenh-Yih
2010-09-01
A lithography-free method for fabricating the nanogrids and quasi-beehive nanostructures on Si substrates is developed. It combines sequential treatments of thermal annealing with reactive ion etching (RIE) on SiGe thin films grown on (100)-Si substrates. The SiGe thin films deposited by ultrahigh vacuum chemical vapor deposition form self-assembled nanoislands via the strain-induced surface roughening (Asaro-Tiller-Grinfeld instability) during thermal annealing, which, in turn, serve as patterned sacrifice regions for subsequent RIE process carried out for fabricating nanogrids and beehive-like nanostructures on Si substrates. The scanning electron microscopy and atomic force microscopy observations confirmed that the resultant pattern of the obtained structures can be manipulated by tuning the treatment conditions, suggesting an interesting alternative route of producing self-organized nanostructures.
Report for MaRIE Drivers Workshop on needs for energetic material's studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Specht, Paul Elliott
Energetic materials (i.e. explosives, propellants, and pyrotechnics) have complex mesoscale features that influence their dynamic response. Direct measurement of the complex mechanical, thermal, and chemical response of energetic materials is critical for improving computational models and enabling predictive capabilities. Many of the physical phenomena of interest in energetic materials cover time and length scales spanning several orders of magnitude. Examples include chemical interactions in the reaction zone, the distribution and evolution of temperature fields, mesoscale deformation in heterogeneous systems, and phase transitions. This is particularly true for spontaneous phenomena, like thermal cook-off. The ability for MaRIE to capture multiple lengthmore » scales and stochastic phenomena can significantly advance our understanding of energetic materials and yield more realistic, predictive models.« less
Medication Errors in Patients with Enteral Feeding Tubes in the Intensive Care Unit.
Sohrevardi, Seyed Mojtaba; Jarahzadeh, Mohammad Hossein; Mirzaei, Ehsan; Mirjalili, Mahtabalsadat; Tafti, Arefeh Dehghani; Heydari, Behrooz
2017-01-01
Most patients admitted to Intensive Care Units (ICU) have problems in using oral medication or ingesting solid forms of drugs. Selecting the most suitable dosage form in such patients is a challenge. The current study was conducted to assess the frequency and types of errors of oral medication administration in patients with enteral feeding tubes or suffering swallowing problems. A cross-sectional study was performed in the ICU of Shahid Sadoughi Hospital, Yazd, Iran. Patients were assessed for the incidence and types of medication errors occurring in the process of preparation and administration of oral medicines. Ninety-four patients were involved in this study and 10,250 administrations were observed. Totally, 4753 errors occurred among the studied patients. The most commonly used drugs were pantoprazole tablet, piracetam syrup, and losartan tablet. A total of 128 different types of drugs and nine different oral pharmaceutical preparations were prescribed for the patients. Forty-one (35.34%) out of 116 different solid drugs (except effervescent tablets and powders) could be substituted by liquid or injectable forms. The most common error was the wrong time of administration. Errors of wrong dose preparation and administration accounted for 24.04% and 25.31% of all errors, respectively. In this study, at least three-fourth of the patients experienced medication errors. The occurrence of these errors can greatly impair the quality of the patients' pharmacotherapy, and more attention should be paid to this issue.
WSi2/Si multilayer sectioning by reactive ion etching for multilayer Laue lens fabrication
NASA Astrophysics Data System (ADS)
Bouet, N.; Conley, R.; Biancarosa, J.; Divan, R.; Macrander, A. T.
2010-09-01
Reactive ion etching (RIE) has been employed in a wide range of fields such as semiconductor fabrication, MEMS (microelectromechanical systems), and refractive x-ray optics with a large investment put towards the development of deep RIE. Due to the intrinsic differing chemistries related to reactivity, ion bombardment, and passivation of materials, the development of recipes for new materials or material systems can require intense effort and resources. For silicon in particular, methods have been developed to provide reliable anisotropic profiles with good dimensional control and high aspect ratios1,2,3, high etch rates, and excellent material to mask etch selectivity. A multilayer Laue lens4 is an x-ray focusing optic, which is produced by depositing many layers of two materials with differing electron density in a particular stacking sequence where the each layer in the stack satisfies the Fresnel zone plate law. When this stack is sectioned to allow side-illumination with radiation, the diffracted exiting radiation will constructively interfere at the focal point. Since the first MLLs were developed at Argonne in the USA in 20064, there have been published reports of MLL development efforts in Japan5, and, very recently, also in Germany6. The traditional technique for sectioning multilayer Laue lens (MLL) involves mechanical sectioning and polishing7, which is labor intensive and can induce delamination or structure damage and thereby reduce yield. If a non-mechanical technique can be used to section MLL, it may be possible to greatly shorten the fabrication cycle, create more usable optics from the same amount of deposition substrate, and perhaps develop more advanced structures to provide greater stability or flexibility. Plasma etching of high aspect-ratio multilayer structures will also expand the scope for other types of optics fabrication (such as gratings, zone plates, and so-on). However, well-performing reactive ion etching recipes have been developed for only a small number of materials, and even less recipes exist for concurrent etching of more than one element so a fully material specific process needs to be developed. In this paper, sectioning of WSi2/Si multilayers for MLL fabrication using fluorinated gases is investigated. The main goals were to demonstrate the feasibility of this technique, achievement of high anisotropy, adequate sidewall roughness control and high etching rates. We note that this development for MLL sidewalls should be distinguished from work on improving aspect ratios in traditional Fresnel zone plates. Aspect ratios for MLL sidewalls are not similarly constrained.
The Effectiveness of Extensive versus Intensive Recasts for Learning L2 Grammar
ERIC Educational Resources Information Center
Nassaji, Hossein
2017-01-01
This study investigated the effects of extensive versus intensive recasts. The focus was on the effect of feedback on learning English articles, which, as nonsalient target structures, have been shown to be difficult for many second language learners. Intensive recasts were operationalized as recasts provided on article errors only, while…
Brannon, Timothy S
2006-01-01
Continuous infusion intravenous (IV) drugs in neonatal intensive care are usually prepared based on patient weight so that the dose is readable as a simple multiple of the infusion pump rate. New safety guidelines propose that hospitals switch to using standardized admixtures of these drugs to prevent calculation errors during ad hoc preparation. Extended hierarchical task analysis suggests that switching to standardized admixtures may lead to more errors in programming the pump at the bedside.
Brannon, Timothy S.
2006-01-01
Continuous infusion intravenous (IV) drugs in neonatal intensive care are usually prepared based on patient weight so that the dose is readable as a simple multiple of the infusion pump rate. New safety guidelines propose that hospitals switch to using standardized admixtures of these drugs to prevent calculation errors during ad hoc preparation. Extended hierarchical task analysis suggests that switching to standardized admixtures may lead to more errors in programming the pump at the bedside. PMID:17238482
Roon, David A.; Waits, L.P.; Kendall, K.C.
2005-01-01
Non-invasive genetic sampling (NGS) is becoming a popular tool for population estimation. However, multiple NGS studies have demonstrated that polymerase chain reaction (PCR) genotyping errors can bias demographic estimates. These errors can be detected by comprehensive data filters such as the multiple-tubes approach, but this approach is expensive and time consuming as it requires three to eight PCR replicates per locus. Thus, researchers have attempted to correct PCR errors in NGS datasets using non-comprehensive error checking methods, but these approaches have not been evaluated for reliability. We simulated NGS studies with and without PCR error and 'filtered' datasets using non-comprehensive approaches derived from published studies and calculated mark-recapture estimates using CAPTURE. In the absence of data-filtering, simulated error resulted in serious inflations in CAPTURE estimates; some estimates exceeded N by ??? 200%. When data filters were used, CAPTURE estimate reliability varied with per-locus error (E??). At E?? = 0.01, CAPTURE estimates from filtered data displayed < 5% deviance from error-free estimates. When E?? was 0.05 or 0.09, some CAPTURE estimates from filtered data displayed biases in excess of 10%. Biases were positive at high sampling intensities; negative biases were observed at low sampling intensities. We caution researchers against using non-comprehensive data filters in NGS studies, unless they can achieve baseline per-locus error rates below 0.05 and, ideally, near 0.01. However, we suggest that data filters can be combined with careful technique and thoughtful NGS study design to yield accurate demographic information. ?? 2005 The Zoological Society of London.
Zhang, You; Ma, Jianhua; Iyengar, Puneeth; Zhong, Yuncheng; Wang, Jing
2017-01-01
Purpose Sequential same-patient CT images may involve deformation-induced and non-deformation-induced voxel intensity changes. An adaptive deformation recovery and intensity correction (ADRIC) technique was developed to improve the CT reconstruction accuracy, and to separate deformation from non-deformation-induced voxel intensity changes between sequential CT images. Materials and Methods ADRIC views the new CT volume as a deformation of a prior high-quality CT volume, but with additional non-deformation-induced voxel intensity changes. ADRIC first applies the 2D-3D deformation technique to recover the deformation field between the prior CT volume and the new, to-be-reconstructed CT volume. Using the deformation-recovered new CT volume, ADRIC further corrects the non-deformation-induced voxel intensity changes with an updated algebraic reconstruction technique (‘ART-dTV’). The resulting intensity-corrected new CT volume is subsequently fed back into the 2D-3D deformation process to further correct the residual deformation errors, which forms an iterative loop. By ADRIC, the deformation field and the non-deformation voxel intensity corrections are optimized separately and alternately to reconstruct the final CT. CT myocardial perfusion imaging scenarios were employed to evaluate the efficacy of ADRIC, using both simulated data of the extended-cardiac-torso (XCAT) digital phantom and experimentally acquired porcine data. The reconstruction accuracy of the ADRIC technique was compared to the technique using ART-dTV alone, and to the technique using 2D-3D deformation alone. The relative error metric and the universal quality index metric are calculated between the images for quantitative analysis. The relative error is defined as the square root of the sum of squared voxel intensity differences between the reconstructed volume and the ‘ground-truth’ volume, normalized by the square root of the sum of squared ‘ground-truth’ voxel intensities. In addition to the XCAT and porcine studies, a physical lung phantom measurement study was also conducted. Water-filled balloons with various shapes/volumes and concentrations of iodinated contrasts were put inside the phantom to simulate both deformations and non-deformation-induced intensity changes for ADRIC reconstruction. The ADRIC-solved deformations and intensity changes from limited-view projections were compared to those of the ‘gold-standard’ volumes reconstructed from fully-sampled projections. Results For the XCAT simulation study, the relative errors of the reconstructed CT volume by the 2D-3D deformation technique, the ART-dTV technique and the ADRIC technique were 14.64%, 19.21% and 11.90% respectively, by using 20 projections for reconstruction. Using 60 projections for reconstruction reduced the relative errors to 12.33%, 11.04% and 7.92% for the three techniques, respectively. For the porcine study, the corresponding results were 13.61%, 8.78%, 6.80% by using 20 projections; and 12.14%, 6.91% and 5.29% by using 60 projections. The ADRIC technique also demonstrated robustness to varying projection exposure levels. For the physical phantom study, the average DICE coefficient between the initial prior balloon volume and the new ‘gold-standard’ balloon volumes was 0.460. ADRIC reconstruction by 21 projections increased the average DICE coefficient to 0.954. Conclusion The ADRIC technique outperformed both the 2D-3D deformation technique and the ART-dTV technique in reconstruction accuracy. The alternately solved deformation field and non-deformation voxel intensity corrections can benefit multiple clinical applications, including tumor tracking, radiotherapy dose accumulation and treatment outcome analysis. PMID:28380247
The culture of patient safety in an Iranian intensive care unit.
Abdi, Zhaleh; Delgoshaei, Bahram; Ravaghi, Hamid; Abbasi, Mohsen; Heyrani, Ali
2015-04-01
To explore nurses' and physicians' attitudes and perceptions relevant to safety culture and to elicit strategies to promote safety culture in an intensive care unit. A strong safety culture is essential to ensure patient safety in the intensive care unit. This case study adopted a mixed method design. The Safety Attitude Questionnaire (SAQ-ICU version), assessing the safety climate through six domains, was completed by nurses and physicians (n = 42) in an academic intensive care unit. Twenty semi-structured interviews and document analyses were conducted as well. Interviews were analysed using a framework analysis method. Mean scores across the six domains ranged from 52.3 to 72.4 on a 100-point scale. Further analysis indicated that there were statistically significant differences between physicians' and nurses' attitudes toward teamwork (mean scores: 64.5/100 vs. 52.6/100, d = 1.15, t = 3.69, P < 0.001) and job satisfaction (mean scores: 78.2/100 vs. 57.7/100, d = 1.5, t = 4.8, P < 0.001). Interviews revealed several safety challenges including underreporting, failure to learn from errors, lack of speaking up, low job satisfaction among nurses and ineffective nurse-physician communication. The results indicate that all the domains need improvements. However, further attention should be devoted to error reporting and analysis, communication and teamwork among professional groups, and nurses' job satisfaction. Nurse managers can contribute to promoting a safety culture by encouraging staff to report errors, fostering learning from errors and addressing inter-professional communication problems. © 2013 John Wiley & Sons Ltd.
Qu, Conghui; Schuetz, Johanna M.; Min, Jeong Eun; Leach, Stephen; Daley, Denise; Spinelli, John J.; Brooks-Wilson, Angela; Graham, Jinko
2011-01-01
We describe a statistical approach to predict gender-labeling errors in candidate-gene association studies, when Y-chromosome markers have not been included in the genotyping set. The approach adds value to methods that consider only the heterozygosity of X-chromosome SNPs, by incorporating available information about the intensity of X-chromosome SNPs in candidate genes relative to autosomal SNPs from the same individual. To our knowledge, no published methods formalize a framework in which heterozygosity and relative intensity are simultaneously taken into account. Our method offers the advantage that, in the genotyping set, no additional space is required beyond that already assigned to X-chromosome SNPs in the candidate genes. We also show how the predictions can be used in a two-phase sampling design to estimate the gender-labeling error rates for an entire study, at a fraction of the cost of a conventional design. PMID:22303327
NASA Astrophysics Data System (ADS)
Tan, Jiubin; Qiang, Xifu; Ding, Xuemei
1991-08-01
Optical sensors have two notable advantages in modern precision measurement. One is that they can be used in nondestructive measurement because the sensors need not touch the surfaces of workpieces in measuring. The other one is that they can strongly resist electromagnetic interferences, vibrations, and noises, so they are suitable to be used in machining sites. But the drift of light intensity and the changing of the reflection coefficient at different measuring positions of a workpiece may have great influence on measured results. To solve the problem, a spectroscopic differential characteristic compensating method is put forward. The method can be used effectively not only in compensating the measuring errors resulted from the drift of light intensity but also in eliminating the influence to measured results caused by the changing of the reflection coefficient. Also, the article analyzes the possibility of and the means of separating data errors of a clinical measuring system for form and position errors of circular workpieces.
Nithiananthan, Sajendra; Schafer, Sebastian; Uneri, Ali; Mirota, Daniel J; Stayman, J Webster; Zbijewski, Wojciech; Brock, Kristy K; Daly, Michael J; Chan, Harley; Irish, Jonathan C; Siewerdsen, Jeffrey H
2011-04-01
A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values ("intensity"). A variant of the Demons algorithm was developed in which an estimate of the relationship between CT and CBCT intensity values for specific materials in the image is computed at each iteration based on the set of currently overlapping voxels. This tissue-specific intensity correction is then used to estimate the registration output for that iteration and the process is repeated. The robustness of the method was tested in CBCT images of a cadaveric head exhibiting a broad range of simulated intensity variations associated with x-ray scatter, object truncation, and/or errors in the reconstruction algorithm. The accuracy of CT-CBCT registration was also measured in six real cases, exhibiting deformations ranging from simple to complex during surgery or radiotherapy guided by a CBCT-capable C-arm or linear accelerator, respectively. The iterative intensity matching approach was robust against all levels of intensity variation examined, including spatially varying errors in voxel value of a factor of 2 or more, as can be encountered in cases of high x-ray scatter. Registration accuracy without intensity matching degraded severely with increasing magnitude of intensity error and introduced image distortion. A single histogram match performed prior to registration alleviated some of these effects but was also prone to image distortion and was quantifiably less robust and accurate than the iterative approach. Within the six case registration accuracy study, iterative intensity matching Demons reduced mean TRE to (2.5 +/- 2.8) mm compared to (3.5 +/- 3.0) mm with rigid registration. A method was developed to iteratively correct CT-CBCT intensity disparity during Demons registration, enabling fast, intensity-based registration in CBCT-guided procedures such as surgery and radiotherapy, in which CBCT voxel values may be inaccurate. Accurate CT-CBCT registration in turn facilitates registration of multimodality preoperative image and planning data to intraoperative CBCT by way of the preoperative CT, thereby linking the intraoperative frame of reference to a wealth of preoperative information that could improve interventional guidance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meng, Xiangyu; Shi, Xianbo; Wang, Yong
The mutual optical intensity (MOI) model is extended to include the propagation of partially coherent radiation through non-ideal mirrors. The propagation of the MOI from the incident to the exit plane of the mirror is realised by local ray tracing. The effects of figure errors can be expressed as phase shifts obtained by either the phase projection approach or the direct path length method. Using the MOI model, the effects of figure errors are studied for diffraction-limited cases using elliptical cylinder mirrors. Figure errors with low spatial frequencies can vary the intensity distribution, redistribute the local coherence function and distortmore » the wavefront, but have no effect on the global degree of coherence. The MOI model is benchmarked againstHYBRIDand the multi-electronSynchrotron Radiation Workshop(SRW) code. The results show that the MOI model gives accurate results under different coherence conditions of the beam. Other than intensity profiles, the MOI model can also provide the wavefront and the local coherence function at any location along the beamline. The capability of tuning the trade-off between accuracy and efficiency makes the MOI model an ideal tool for beamline design and optimization.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de; Department of Medical Physics, German Cancer Research Center, Heidelberg; Giske, Kristina
Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived frommore » a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.« less
Li, Ting [Ventura, CA
2011-04-26
The surface morphology of an LED light emitting surface is changed by applying a reactive ion etch (RIE) process to the light emitting surface. High aspect ratio, submicron roughness is formed on the light emitting surface by transferring a thin film metal hard-mask having submicron patterns to the surface prior to applying a reactive ion etch process. The submicron patterns in the metal hard-mask can be formed using a low cost, commercially available nano-patterned template which is transferred to the surface with the mask. After subsequently binding the mask to the surface, the template is removed and the RIE process is applied for time duration sufficient to change the morphology of the surface. The modified surface contains non-symmetric, submicron structures having high aspect ratio which increase the efficiency of the device.
Sankoff, Jeffrey; Taub, Julie; Mintzer, David
2013-01-01
The use of Lean tools for quality improvement and process refinement is gaining acceptance in many health care institutions. Traditionally, these tools are used to apply incremental changes to established processes in order to reduce waste and improve quality. In this article, the authors describe a novel Lean methodology, the Rapid Improvement Event (RIE), used in a unique way to develop a new treatment protocol for a specific medical condition: alcohol withdrawal. The RIE allowed for the collaboration of a multidisciplinary group of providers invested in the success of a new protocol for alcohol withdrawal that spans areas from the emergency department to the inpatient ward at an inner-city safety net hospital. It also allowed for the definition of measures for its success once it is implemented.
Scislowska-Czarnecka, Anna; Szmigiel, Dariusz; Genet, Michel; Dupont-Gillain, Christine; Pamula, Elzbieta; Kolaczkowska, Elzbieta
2015-12-01
Here, we report on modification of one of the model biomedical polymers, poly L-lactide-co-glycolide (PLGA; 85:15), by reactive ion etching (RIE) oxygen plasma treatment. PLGA's major disadvantage is high hydrophobicity which restrains binding of cell-adhesive proteins and host cells. In the current approach, we aimed to answer two questions: (1) will only short (10 s) and moderate (20-200 mTorr, 45-90 W) RIE oxygen plasma treatment, leading to decrease of water contact angle by only up to 10°, sufficiently improve PLGA adherence to cells, and (2) how will this affect osteoblasts and activation of the immune system? All obtained modified PLGAs had improved hydrophilicity but unaltered roughness (as revealed by water contact angle measurements, X-ray photoelectron spectroscopy, and atomic force microscopy) resulting in significantly improved adhesion of osteoblasts (MG-63) and their low activation. Importantly, macrophages (RAW 264.7), one of the key cells initiating inflammation and bone resorption, responded significantly less vigorously to the modified polymers, expressing/releasing lower amounts of nitric oxide, matrix metalloproteinases (MMP-9), and pro-inflammatory cytokines (TNF-α, IL-6, IL-12p70, IFN-γ, IL-10). We conclude that already slight RIE oxygen plasma modification of PLGA is sufficient to improve its surface properties, and enhance cytocompatibility. Most importantly, this type of modification prevents excessive immune response. © 2015 Wiley Periodicals, Inc.
Possibility for ultra-bright electron beam acceleration in dielectric wakefield accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simakov, Evgenya I.; Carlsten, Bruce E.; Shchegolkov, Dmitry Yu.
2012-12-21
We describe a conceptual proposal to combine the Dielectric Wakefield Accelerator (DWA) with the Emittance Exchanger (EEX) to demonstrate a high-brightness DWA with a gradient of above 100 MV/m and less than 0.1% induced energy spread in the accelerated beam. We currently evaluate the DWA concept as a performance upgrade for the future LANL signature facility MaRIE with the goal of significantly reducing the electron beam energy spread. The preconceptual design for MaRIE is underway at LANL, with the design of the electron linear accelerator being one of the main research goals. Although generally the baseline design needs to bemore » conservative and rely on existing technology, any future upgrade would immediately call for looking into the advanced accelerator concepts capable of boosting the electron beam energy up by a few GeV in a very short distance without degrading the beam's quality. Scoping studies have identified large induced energy spreads as the major cause of beam quality degradation in high-gradient advanced accelerators for free-electron lasers. We describe simulations demonstrating that trapezoidal bunch shapes can be used in a DWA to greatly reduce the induced beam energy spread, and, in doing so, also preserve the beam brightness at levels never previously achieved. This concept has the potential to advance DWA technology to a level that would make it suitable for the upgrades of the proposed Los Alamos MaRIE signature facility.« less
Fabrication of 3D surface structures using grayscale lithography
NASA Astrophysics Data System (ADS)
Stilson, Christopher; Pal, Rajan; Coutu, Ronald A.
2014-03-01
The ability to design and develop 3D microstructures is important for microelectromechanical systems (MEMS) fabrication. Previous techniques used to create 3D devices included tedious steps in direct writing and aligning patterns onto a substrate followed by multiple photolithography steps using expensive, customized equipment. Additionally, these techniques restricted batch processing and placed limits on achievable shapes. Gray-scale lithography enables the fabrication of a variety of shapes using a single photolithography step followed by reactive ion etching (RIE). Micromachining 3D silicon structures for MEMS can be accomplished using gray-scale lithography along with dry anisotropic etching. In this study, we investigated: using MATLAB for mask designs; feasibility of using 1 μm Heidelberg mask maker to direct write patterns onto photoresist; using RIE processing to etch patterns into a silicon substrate; and the ability to tailor etch selectivity for precise fabrication. To determine etch rates and to obtain desired etch selectivity, parameters such as gas mixture, gas flow, and electrode power were studied. This process successfully demonstrates the ability to use gray-scale lithography and RIE for use in the study of micro-contacts. These results were used to produce a known engineered non-planer surface for testing micro-contacts. Surface structures are between 5 μm and 20 μm wide with varying depths and slopes based on mask design and etch rate selectivity. The engineered surfaces will provide more insight into contact geometries and failure modes of fixed-fixed micro-contacts.
System calibration method for Fourier ptychographic microscopy.
Pan, An; Zhang, Yan; Zhao, Tianyu; Wang, Zhaojun; Dan, Dan; Lei, Ming; Yao, Baoli
2017-09-01
Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging technique with both high-resolution and wide field of view. In current FPM imaging platforms, systematic error sources come from aberrations, light-emitting diode (LED) intensity fluctuation, parameter imperfections, and noise, all of which may severely corrupt the reconstruction results with similar artifacts. Therefore, it would be unlikely to distinguish the dominating error from these degraded reconstructions without any preknowledge. In addition, systematic error is generally a mixture of various error sources in the real situation, and it cannot be separated due to their mutual restriction and conversion. To this end, we report a system calibration procedure, termed SC-FPM, to calibrate the mixed systematic errors simultaneously from an overall perspective, based on the simulated annealing algorithm, the LED intensity correction method, the nonlinear regression process, and the adaptive step-size strategy, which involves the evaluation of an error metric at each iteration step, followed by the re-estimation of accurate parameters. The performance achieved both in simulations and experiments demonstrates that the proposed method outperforms other state-of-the-art algorithms. The reported system calibration scheme improves the robustness of FPM, relaxes the experiment conditions, and does not require any preknowledge, which makes the FPM more pragmatic. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Impact of ITRS 2014 realizations on altimeter satellite precise orbit determination
NASA Astrophysics Data System (ADS)
Zelensky, Nikita P.; Lemoine, Frank G.; Beckley, Brian D.; Chinn, Douglas S.; Pavlis, Despina E.
2018-01-01
This paper evaluates orbit accuracy and systematic error for altimeter satellite precise orbit determination on TOPEX, Jason-1, Jason-2 and Jason-3 by comparing the use of four SLR/DORIS station complements from the International Terrestrial Reference System (ITRS) 2014 realizations with those based on ITRF2008. The new Terrestrial Reference Frame 2014 (TRF2014) station complements include ITRS realizations from the Institut National de l'Information Géographique et Forestière (IGN) ITRF2014, the Jet Propulsion Laboratory (JPL) JTRF2014, the Deutsche Geodätisches Forschungsinstitut (DGFI) DTRF2014, and the DORIS extension to ITRF2014 for Precise Orbit Determination, DPOD2014. The largest source of error stems from ITRF2008 station position extrapolation past the 2009 solution end time. The TRF2014 SLR/DORIS complement impact on the ITRF2008 orbit is only 1-2 mm RMS radial difference between 1992-2009, and increases after 2009, up to 5 mm RMS radial difference in 2016. Residual analysis shows that station position extrapolation error past the solution span becomes evident even after two years, and will contribute to about 3-4 mm radial orbit error after seven years. Crossover data show the DTRF2014 orbits are the most accurate for the TOPEX and Jason-2 test periods, and the JTRF2014 orbits for the Jason-1 period. However for the 2016 Jason-3 test period only the DPOD2014-based orbits show a strong and statistically significant margin of improvement. The positive results with DTRF2014 suggest the new approach to correct station positions or normal equations for non-tidal loading before combination is beneficial. We did not find any compelling POD advantage in using non-linear over linear station velocity models in our SLR & DORIS orbit tests on the Jason satellites. The JTRF2014 proof-of-concept ITRS realization demonstrates the need for improved SLR+DORIS orbit centering when compared to the Ries (2013) CM annual model. Orbit centering error is seen as an annual radial signal of 0.4 mm amplitude with the CM model. The unmodeled CM signals show roughly a 1.8 mm peak-to-peak annual variation in the orbit radial component. We find the TRF network stability pertinent to POD can be defined only by examination of the orbit-specific tracking network time series. Drift stability between the ITRF2008 and the other TRF2014-based orbits is very high, the relative mean radial drift error over water is no larger than 0.04 mm/year over 1993-2015. Analyses also show TRF induced orbit error meets current altimeter rate accuracy goals for global and regional sea level estimation.
Farzi, Sedigheh; Moladoost, Azam; Bahrami, Masoud; Farzi, Saba; Etminani, Reza
2017-01-01
One of the goals of nursing is providing safe care, prevention of injury, and health promotion of patients. Patient safety in intensive care units is threatened for various reasons. This study aimed to survey patient safety culture from the perspective of nurses in intensive care units. This cross-sectional study was conducted in 2016. Sampling was done using the convenience method. The sample consisted of 367 nurses working in intensive care units of teaching hospitals affiliated to Isfahan University of Medical Sciences. Data collection was performed using a two-part questionnaire that included demographic and hospital survey on Patient Safety Culture (HSOPSC) questionnaire. Data analysis was done using descriptive statistics (mean and standard deviation). Among the 12 dimensions of safety culture, the nurses assigned the highest score to "team work within units" (97.3%) and "Organizational learning-continuous improvement" (84%). They assigned the least score to "handoffs and transitions"(21.1%), "non-punitive response to errors" (24.7%), "Staffing" (35.6%), "Communication openness" (47.5%), and "Teamwork across units" (49.4%). The patient safety culture dimensions have low levels that require adequate attention and essential measures of health care centers including facilitating teamwork, providing adequate staff, and developing a checklist of handoffs and transitions. Furthermore, to increase reporting error and to promote a patient safety culture in intensive care units, some strategies should be adopted including a system-based approach to deal with the error.
Shulman, Rob; Singer, Mervyn; Goldstone, John; Bellingan, Geoff
2005-10-05
The study aimed to compare the impact of computerised physician order entry (CPOE) without decision support with hand-written prescribing (HWP) on the frequency, type and outcome of medication errors (MEs) in the intensive care unit. Details of MEs were collected before, and at several time points after, the change from HWP to CPOE. The study was conducted in a London teaching hospital's 22-bedded general ICU. The sampling periods were 28 weeks before and 2, 10, 25 and 37 weeks after introduction of CPOE. The unit pharmacist prospectively recorded details of MEs and the total number of drugs prescribed daily during the data collection periods, during the course of his normal chart review. The total proportion of MEs was significantly lower with CPOE (117 errors from 2429 prescriptions, 4.8%) than with HWP (69 errors from 1036 prescriptions, 6.7%) (p < 0.04). The proportion of errors reduced with time following the introduction of CPOE (p < 0.001). Two errors with CPOE led to patient harm requiring an increase in length of stay and, if administered, three prescriptions with CPOE could potentially have led to permanent harm or death. Differences in the types of error between systems were noted. There was a reduction in major/moderate patient outcomes with CPOE when non-intercepted and intercepted errors were combined (p = 0.01). The mean baseline APACHE II score did not differ significantly between the HWP and the CPOE periods (19.4 versus 20.0, respectively, p = 0.71). Introduction of CPOE was associated with a reduction in the proportion of MEs and an improvement in the overall patient outcome score (if intercepted errors were included). Moderate and major errors, however, remain a significant concern with CPOE.
Intensive Treatment with Ultrasound Visual Feedback for Speech Sound Errors in Childhood Apraxia
Preston, Jonathan L.; Leece, Megan C.; Maas, Edwin
2016-01-01
Ultrasound imaging is an adjunct to traditional speech therapy that has shown to be beneficial in the remediation of speech sound errors. Ultrasound biofeedback can be utilized during therapy to provide clients with additional knowledge about their tongue shapes when attempting to produce sounds that are erroneous. The additional feedback may assist children with childhood apraxia of speech (CAS) in stabilizing motor patterns, thereby facilitating more consistent and accurate productions of sounds and syllables. However, due to its specialized nature, ultrasound visual feedback is a technology that is not widely available to clients. Short-term intensive treatment programs are one option that can be utilized to expand access to ultrasound biofeedback. Schema-based motor learning theory suggests that short-term intensive treatment programs (massed practice) may assist children in acquiring more accurate motor patterns. In this case series, three participants ages 10–14 years diagnosed with CAS attended 16 h of speech therapy over a 2-week period to address residual speech sound errors. Two participants had distortions on rhotic sounds, while the third participant demonstrated lateralization of sibilant sounds. During therapy, cues were provided to assist participants in obtaining a tongue shape that facilitated a correct production of the erred sound. Additional practice without ultrasound was also included. Results suggested that all participants showed signs of acquisition of sounds in error. Generalization and retention results were mixed. One participant showed generalization and retention of sounds that were treated; one showed generalization but limited retention; and the third showed no evidence of generalization or retention. Individual characteristics that may facilitate generalization are discussed. Short-term intensive treatment programs using ultrasound biofeedback may result in the acquisition of more accurate motor patterns and improved articulation of sounds previously in error, with varying levels of generalization and retention. PMID:27625603
ON COMPUTING UPPER LIMITS TO SOURCE INTENSITIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kashyap, Vinay L.; Siemiginowska, Aneta; Van Dyk, David A.
2010-08-10
A common problem in astrophysics is determining how bright a source could be and still not be detected in an observation. Despite the simplicity with which the problem can be stated, the solution involves complicated statistical issues that require careful analysis. In contrast to the more familiar confidence bound, this concept has never been formally analyzed, leading to a great variety of often ad hoc solutions. Here we formulate and describe the problem in a self-consistent manner. Detection significance is usually defined by the acceptable proportion of false positives (background fluctuations that are claimed as detections, or Type I error),more » and we invoke the complementary concept of false negatives (real sources that go undetected, or Type II error), based on the statistical power of a test, to compute an upper limit to the detectable source intensity. To determine the minimum intensity that a source must have for it to be detected, we first define a detection threshold and then compute the probabilities of detecting sources of various intensities at the given threshold. The intensity that corresponds to the specified Type II error probability defines that minimum intensity and is identified as the upper limit. Thus, an upper limit is a characteristic of the detection procedure rather than the strength of any particular source. It should not be confused with confidence intervals or other estimates of source intensity. This is particularly important given the large number of catalogs that are being generated from increasingly sensitive surveys. We discuss, with examples, the differences between these upper limits and confidence bounds. Both measures are useful quantities that should be reported in order to extract the most science from catalogs, though they answer different statistical questions: an upper bound describes an inference range on the source intensity, while an upper limit calibrates the detection process. We provide a recipe for computing upper limits that applies to all detection algorithms.« less
The wildgeographer avatar shows how to measure soil erosion rates by means of a rainfall simulator
NASA Astrophysics Data System (ADS)
Cerdà, Artemi; González Pelayo, Óscar; Pereira, Paulo; Novara, Agata; Iserloh, Thomas; Prosdocimi, Massimo
2015-04-01
This contribution to the immersed worlds wish to develop the avatar that will teach the students and other scientists how to develop measurements of soil erosion, surface runoff and wetting fronts by means of simulated rainfall experiments. Rainfall simulation is a well established and knows methodology to measure the soil erosion rates and soil hydrology under controlled conditions (Cerdà 1998a; Cerdà, 1998b; Cerdà and Jurgensen, 2011; Dunkerley, 2012; Iserloh et al., 2012; Iserloh et al., 2013; Ziadat and Taimeh, 2013; Butzen et al., 2014). However, is a method that requires a long training and expertise to avoid mismanagement and mistaken. To use and avatar can help in the teaching of the technique and the dissemination of the findings. This contribution will show to other avatars how to develop an experiment with simulated rainfall and will help to take the right decision in the design of the experiments. Following the main parts of the experiments and measurements the Wildgeographer avatar must develop: 1. Determine the objectives and decide which rainfall intensity and distribution, and which plot size to be used. Choose between a laboratory or a field rainfall simulation. 2. Design of the rainfall simulator to achieve the objectives: type of rainfall simulator (sprayer or drop former) and calibrate. 3. The experiments are carried out. 4. The results are show. Acknowledgements To the "Ministerio de Economía and Competitividad" of Spanish Government for finance the POSTFIRE project (CGL2013- 47862-C2-1-R). The research projects GL2008-02879/BTE, LEDDRA 243857 and PREVENTING AND REMEDIATING DEGRADATION OF SOILS IN EUROPE THROUGH LAND CARE (RECARE)FP7-ENV-2013- supported this research. References Butzen, V., Seeger, M., Wirtz, S., Huemann, M., Mueller, C., Casper, M., Ries, J. B. 2014. Quantification of Hortonian overland flow generation and soil erosion in a Central European low mountain range using rainfall experiments. Catena, 113, 202-212. Cerdà, A. 1998a. Effect of climate on surface flow along a climatological gradient in Israel. A field rainfall simulation approach. Journal of Arid Environments, 38, 145-159. Cerdà, A. 1998b. The influence of aspect and vegetation on seasonal changes in erosion under rainfall simulation on a clay soil in Spain. Canadian Journal of Soil Science, 78, 321-330. Cerdà, A., Jurgensen, M. F. 2011. Ant mounds as a source of sediment on citrus orchard plantations in eastern Spain. A three-scale rainfall simulation approach. Catena, 85(3), 231-236. Dunkerley, D. 2012. Effects of rainfall intensity fluctuations on infiltration and runoff: rainfall simulation on dryland soils, Fowlers Gap, Australia. Hydrological Processes, 26(15), 2211-2224. Iserloh, T., Ries, J.B., Arnaez, J., Boix Fayos, C., Butzen, V., Cerdà, A., Echeverría, M.T., Fernández-Gálvez, J., Fister, W., Geißler, C., Gómez, J.A., Gómez-Macpherson, H., Kuhn, N.J., Lázaro, R., León, F.J., Martínez-Mena, M., Martínez-Murillo, J.F., Marzen, M., Mingorance, M.D., Ortigosa, L., Peters, P., Regüés, D., Ruiz-Sinoga, J.D., Scholten, T., Seeger, M., Solé-Benet, A., Wengel, R., Wirtz, S. 2013. European small portable rainfall simulators: a comparison of rainfall characteristics. Catena, 110, 100-112. Doi: 10.1016/j.catena.2013.05.013 Iserloh, T., Ries, J.B., Cerdà, A., Echeverría, M.T., Fister, W., Geißler, C., Kuhn, N.J., León, F.J., Peters, P., Schindewolf, M., Schmidt, J., Scholten, T., Seeger, M. (2012): Comparative measurements with seven rainfall simulators on uniform bare fallow land. Zeitschrift für Geomorphologie, 57, 193-201. DOI: 10.1127/0372- 8854/2012/S-00118. Ziadat, F. M., Taimeh, A. Y. 2013. Effect of rainfall intensity, slope and land use and antecedent soil moisture on soil erosion in an arid environment. Land Degradation & Development, 24: 582- 590. DOI 10.1002/ldr.2239
NASA Astrophysics Data System (ADS)
Lei, Hebing; Yao, Yong; Liu, Haopeng; Tian, Yiting; Yang, Yanfu; Gu, Yinglong
2018-06-01
An accurate algorithm by combing Gram-Schmidt orthonormalization and least square ellipse fitting technology is proposed, which could be used for phase extraction from two or three interferograms. The DC term of background intensity is suppressed by subtraction operation on three interferograms or by high-pass filter on two interferograms. Performing Gram-Schmidt orthonormalization on pre-processing interferograms, the phase shift error is corrected and a general ellipse form is derived. Then the background intensity error and the corrected error could be compensated by least square ellipse fitting method. Finally, the phase could be extracted rapidly. The algorithm could cope with the two or three interferograms with environmental disturbance, low fringe number or small phase shifts. The accuracy and effectiveness of the proposed algorithm are verified by both of the numerical simulations and experiments.
Influences of optical-spectrum errors on excess relative intensity noise in a fiber-optic gyroscope
NASA Astrophysics Data System (ADS)
Zheng, Yue; Zhang, Chunxi; Li, Lijing
2018-03-01
The excess relative intensity noise (RIN) generated from broadband sources degrades the angular-random-walk performance of a fiber-optic gyroscope dramatically. Many methods have been proposed and managed to suppress the excess RIN. However, the properties of the excess RIN under the influences of different optical errors in the fiber-optic gyroscope have not been systematically investigated. Therefore, it is difficult for the existing RIN-suppression methods to achieve the optimal results in practice. In this work, the influences of different optical-spectrum errors on the power spectral density of the excess RIN are theoretically analyzed. In particular, the properties of the excess RIN affected by the raised-cosine-type ripples in the optical spectrum are elaborately investigated. Experimental measurements of the excess RIN corresponding to different optical-spectrum errors are in good agreement with our theoretical analysis, demonstrating its validity. This work provides a comprehensive understanding of the properties of the excess RIN under the influences of different optical-spectrum errors. Potentially, it can be utilized to optimize the configurations of the existing RIN-suppression methods by accurately evaluating the power spectral density of the excess RIN.
Embedding intensity image into a binary hologram with strong noise resistant capability
NASA Astrophysics Data System (ADS)
Zhuang, Zhaoyong; Jiao, Shuming; Zou, Wenbin; Li, Xia
2017-11-01
A digital hologram can be employed as a host image for image watermarking applications to protect information security. Past research demonstrates that a gray level intensity image can be embedded into a binary Fresnel hologram by error diffusion method or bit truncation coding method. However, the fidelity of the retrieved watermark image from binary hologram is generally not satisfactory, especially when the binary hologram is contaminated with noise. To address this problem, we propose a JPEG-BCH encoding method in this paper. First, we employ the JPEG standard to compress the intensity image into a binary bit stream. Next, we encode the binary bit stream with BCH code to obtain error correction capability. Finally, the JPEG-BCH code is embedded into the binary hologram. By this way, the intensity image can be retrieved with high fidelity by a BCH-JPEG decoder even if the binary hologram suffers from serious noise contamination. Numerical simulation results show that the image quality of retrieved intensity image with our proposed method is superior to the state-of-the-art work reported.
Hybrid Correlation Algorithms. A Bridge Between Feature Matching and Image Correlation,
1979-11-01
spa- tially into groups of pixels. The intensity level preprocessing is designed to compensate for any biases or gain changes in the system ; whereas...number of error sources that affect the performance of the system . It would be desirable to lump these errors into ge- neric categories in discussing... system performance rather than treat- ing each error source separately. Such a generic categorization should possess the following properties: 1. The
NASA Astrophysics Data System (ADS)
Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin
2017-03-01
We show how to calculate the secure final key rate in the four-intensity decoy-state measurement-device-independent quantum key distribution protocol with both source errors and statistical fluctuations with a certain failure probability. Our results rely only on the range of only a few parameters in the source state. All imperfections in this protocol have been taken into consideration without assuming any specific error patterns of the source.
NASA Astrophysics Data System (ADS)
Gronz, Oliver; Rodrigo-Comino, Jesús; Seeger, Manuel
2017-04-01
In Mediterranean agricultural fields, more research is needed to quantify soil loss and to assess runoff generation caused by unsuitable land management strategies (García-Díaz et al., 2017; Keesstra et al., 2016). Nowadays, farmers are increasing the generation of rills and, consequently, enhancing several sub-processes related to soil erosion by water such as headcut retreats, piping or cracks joint to mass movements (Marzolff and Poesen, 2009; Poesen et al., 2003; Rodrigo Comino et al., 2015). This complex problem under different spatiotemporal scales hinders a reliable forecasting of its final consequences (Prasuhn, 2011; Salome et al., 2014). Several researchers pay more attention to point observations, but no to general and connected overviews of processes related to forms and the quantitative functioning of all elements. Therefore, the main goal of this study is to characterize and quantify the rill erosion generated by these degradation processes. To achieve this goal, two runoff experiments were carried out with two repetitions (dry and wet conditions) under extreme conditions (Wirtz et al., 2013, 2012, 2010): a motor driven pump discharged a water inflow up to ˜4.2 l s-1 maintained during between 4 and 6 minutes (≈1000 litres). Additionally, a 3D-captation of the rill by an adapted SfM photogrammetry was performed to assess: i) clear visible zonation of geomorphological (structural) connectivity features; ii) runoff and sediment productions close to the catchment outlet under actual conditions; iii) topsoil-subsoil interaction and crusting crucial for runoff generation; and, iv) the area with evidence of (former) high erosion intensity now stable, but with remnant. García-Díaz, A., Bienes, R., Sastre, B., Novara, A., Gristina, L., Cerdà, A., 2017. Nitrogen losses in vineyards under different types of soil groundcover. A field runoff simulator approach in central Spain. Agric. Ecosyst. Environ. 236, 256-267. doi:10.1016/j.agee.2016.12.013 Keesstra, S., Pereira, P., Novara, A., Brevik, E.C., Azorin-Molina, C., Parras-Alcántara, L., Jordán, A., Cerdà, A., 2016. Effects of soil management techniques on soil water erosion in apricot orchards. Sci. Total Environ. 551-552, 357-366. doi:10.1016/j.scitotenv.2016.01.182 Marzolff, I., Poesen, J., 2009. The potential of 3D gully monitoring with GIS using high-resolution aerial photography and a digital photogrammetry system. Geomorphology, GIS and SDA applications in geomorphology 111, 48-60. doi:10.1016/j.geomorph.2008.05.047 Poesen, J., Nachtergaele, J., Verstraeten, G., Valentin, C., 2003. Gully erosion and environmental change: importance and research needs. Catena, Gully Erosion and Global Change 50, 91-133. doi:10.1016/S0341-8162(02)00143-1 Rodrigo Comino, J., Brings, C., Lassu, T., Iserloh, T., Senciales, J., Martínez Murillo, J., Ruiz Sinoga, J., Seeger, M., Ries, J., 2015. Rainfall and human activity impacts on soil losses and rill erosion in vineyards (Ruwer Valley, Germany). Solid Earth 6, 823-837. doi:10.5194/se-6-823-2015 Wirtz, S., Seeger, M., Ries, J.B., 2012. Field experiments for understanding and quantification of rill erosion processes. Catena 91, 21-34. doi:http://dx.doi.org/10.1016/j.catena.2010.12.002 Wirtz, S., Seeger, M., Ries, J.B., 2010. The rill experiment as a method to approach a quantification of rill erosion process activity. Z. Für Geomorphol. NF 54, 47-64. Wirtz, S., Seeger, M., Zell, A., Wagner, C., Wagner, J.-F., Ries, J.B., 2013. Applicability of Different Hydraulic Parameters to Describe Soil Detachment in Eroding Rills. PLoS ONE 8, 1-11. doi:10.1371/journal.pone.0064861
NASA Astrophysics Data System (ADS)
Mao, Cuili; Lu, Rongsheng; Liu, Zhijian
2018-07-01
In fringe projection profilometry, the phase errors caused by the nonlinear intensity response of digital projectors needs to be correctly compensated. In this paper, a multi-frequency inverse-phase method is proposed. The theoretical model of periodical phase errors is analyzed. The periodical phase errors can be adaptively compensated in the wrapped maps by using a set of fringe patterns. The compensated phase is then unwrapped with multi-frequency method. Compared with conventional methods, the proposed method can greatly reduce the periodical phase error without calibrating measurement system. Some simulation and experimental results are presented to demonstrate the validity of the proposed approach.
Marsot, Amélie; Michel, Fabrice; Chasseloup, Estelle; Paut, Olivier; Guilhaumou, Romain; Blin, Olivier
2017-10-01
An external evaluation of phenobarbital population pharmacokinetic model described by Marsot et al. was performed in pediatric intensive care unit. Model evaluation is an important issue for dose adjustment. This external evaluation should allow confirming the proposed dosage adaptation and extending these recommendations to the entire intensive care pediatric population. External evaluation of phenobarbital published population pharmacokinetic model of Marsot et al. was realized in a new retrospective dataset of 35 patients hospitalized in a pediatric intensive care unit. The published population pharmacokinetic model was implemented in nonmem 7.3. Predictive performance was assessed by quantifying bias and inaccuracy of model prediction. Normalized prediction distribution errors (NPDE) and visual predictive check (VPC) were also evaluated. A total of 35 infants were studied with a mean age of 33.5 weeks (range: 12 days-16 years) and a mean weight of 12.6 kg (range: 2.7-70.0 kg). The model predicted the observed phenobarbital concentrations with a reasonable bias and inaccuracy. The median prediction error was 3.03% (95% CI: -8.52 to 58.12%), and the median absolute prediction error was 26.20% (95% CI: 13.07-75.59%). No trends in NPDE and VPC were observed. The model previously proposed by Marsot et al. in neonates hospitalized in intensive care unit was externally validated for IV infusion administration. The model-based dosing regimen was extended in all pediatric intensive care unit to optimize treatment. Due to inter- and intravariability in pharmacokinetic model, this dosing regimen should be combined with therapeutic drug monitoring. © 2017 Société Française de Pharmacologie et de Thérapeutique.
Evaluation of a UMLS Auditing Process of Semantic Type Assignments
Gu, Huanying; Hripcsak, George; Chen, Yan; Morrey, C. Paul; Elhanan, Gai; Cimino, James J.; Geller, James; Perl, Yehoshua
2007-01-01
The UMLS is a terminological system that integrates many source terminologies. Each concept in the UMLS is assigned one or more semantic types from the Semantic Network, an upper level ontology for biomedicine. Due to the complexity of the UMLS, errors exist in the semantic type assignments. Finding assignment errors may unearth modeling errors. Even with sophisticated tools, discovering assignment errors requires manual review. In this paper we describe the evaluation of an auditing project of UMLS semantic type assignments. We studied the performance of the auditors who reviewed potential errors. We found that four auditors, interacting according to a multi-step protocol, identified a high rate of errors (one or more errors in 81% of concepts studied) and that results were sufficiently reliable (0.67 to 0.70) for the two most common types of errors. However, reliability was low for each individual auditor, suggesting that review of potential errors is resource-intensive. PMID:18693845
NASA Astrophysics Data System (ADS)
Zhang, Rong-Hua; Tao, Ling-Jiang; Gao, Chuan
2017-09-01
Large uncertainties exist in real-time predictions of the 2015 El Niño event, which have systematic intensity biases that are strongly model-dependent. It is critically important to characterize those model biases so they can be reduced appropriately. In this study, the conditional nonlinear optimal perturbation (CNOP)-based approach was applied to an intermediate coupled model (ICM) equipped with a four-dimensional variational data assimilation technique. The CNOP-based approach was used to quantify prediction errors that can be attributed to initial conditions (ICs) and model parameters (MPs). Two key MPs were considered in the ICM: one represents the intensity of the thermocline effect, and the other represents the relative coupling intensity between the ocean and atmosphere. Two experiments were performed to illustrate the effects of error corrections, one with a standard simulation and another with an optimized simulation in which errors in the ICs and MPs derived from the CNOP-based approach were optimally corrected. The results indicate that simulations of the 2015 El Niño event can be effectively improved by using CNOP-derived error correcting. In particular, the El Niño intensity in late 2015 was adequately captured when simulations were started from early 2015. Quantitatively, the Niño3.4 SST index simulated in Dec. 2015 increased to 2.8 °C in the optimized simulation, compared with only 1.5 °C in the standard simulation. The feasibility and effectiveness of using the CNOP-based technique to improve ENSO simulations are demonstrated in the context of the 2015 El Niño event. The limitations and further applications are also discussed.
NASA Technical Reports Server (NTRS)
Giver, Lawrence P.; Pilewskie, P.; Gore, Warren J.; Freedman, R. S.; Chackerian, C., Jr.; Varanasi, P.
2001-01-01
Several groups have recently been working to improve the near-infrared spectrum of water vapor on HITRAN. The unit-conversion errors found by Giver, et al have now been corrected on the recently released HITRAN-2000. The most important aspect of this article for atmospheric absorption was increasing all the HITRAN-1996 intensities of the 940 nm band by nearly 15%. New intensity measurements of this band by Brown, et al (submitted to J. Mol. Spec.) have now been included in the latest HITRAN. However, Belmiloud, et al discuss new data in the 633-1175 nm region which they expect will substantially increase the calculated absorption of solar radiation by water vapor. They suggest the 4 bands at 725, 820, 940, and 1130 nm are all stronger than the sum of the line intensities currently on HITRAN. For the 725 and 820 nm bands, their recommended intensity increases are 10% and 15%, about the same as previously noted by Grossmann and Browell and Ponsardin and Browell. Belmiloud, et al only suggest a 6% increase for the 940 nm. band over the corrected HITRAN-1996 intensities, but a large 38% increase for the 1130 nm band. The new data discussed by Belmiloud, et al have now been published in greater detail by Schermaul, et al. The intensity increase for the 1130 nm band discussed by Belmiloud, et al is very substantial; it is important to quickly determine if the HITRAN intensity values are in error by as much as they claim. Only intensity errors for the strong lines could result in the total band intensity being in error by such a large amount. To quickly get a number of spectra of the entire near-infrared region from 650 to 1650 nm, we used the Solar Spectral Flux Radiometer with our 25-meter base path White absorption cell. This moderate resolution spectrometer is a flight instrument that has flown on the Sandia Twin Otter for the ARESE 11 experiment. The measured band profiles were then compared to calculated spectra using the latest HITRAN line intensities, convolved with the instrumental resolution. Our spectra for the 725 and 820 nm bands show somewhat more absorption than the HITRAN simulations, about as expected by Belmiloud, el al. The total absorption for our spectra of the 940 nm band agrees well with the HITRAN simulations; this HITRAN spectral region now has the new measurements of Brown, et al. Our spectra of the 1130 nm band have somewhat more absorption than the HITRAN simulations, but not as much as the 38% intensity increase for this band suggested by Belmiloud, et al. An intensity increase of about 20% on average would be more compatible with our data. Finally, our spectra of the 1370 nm band are fairly well modeled by the HITRAN simulations, despite the known problems of the older HITRAN data in this region.
Amorphous Silicon p-i-n Structure Acting as Light and Temperature Sensor
de Cesare, Giampiero; Nascetti, Augusto; Caputo, Domenico
2015-01-01
In this work, we propose a multi-parametric sensor able to measure both temperature and radiation intensity, suitable to increase the level of integration and miniaturization in Lab-on-Chip applications. The device is based on amorphous silicon p-doped/intrinsic/n-doped thin film junction. The device is first characterized as radiation and temperature sensor independently. We found a maximum value of responsivity equal to 350 mA/W at 510 nm and temperature sensitivity equal to 3.2 mV/K. We then investigated the effects of the temperature variation on light intensity measurement and of the light intensity variation on the accuracy of the temperature measurement. We found that the temperature variation induces an error lower than 0.55 pW/K in the light intensity measurement at 550 nm when the diode is biased in short circuit condition, while an error below 1 K/µW results in the temperature measurement when a forward bias current higher than 25 µA/cm2 is applied. PMID:26016913
NASA Astrophysics Data System (ADS)
Kemp, Z. D. C.
2018-04-01
Determining the phase of a wave from intensity measurements has many applications in fields such as electron microscopy, visible light optics, and medical imaging. Propagation based phase retrieval, where the phase is obtained from defocused images, has shown significant promise. There are, however, limitations in the accuracy of the retrieved phase arising from such methods. Sources of error include shot noise, image misalignment, and diffraction artifacts. We explore the use of artificial neural networks (ANNs) to improve the accuracy of propagation based phase retrieval algorithms applied to simulated intensity measurements. We employ a phase retrieval algorithm based on the transport-of-intensity equation to obtain the phase from simulated micrographs of procedurally generated specimens. We then train an ANN with pairs of retrieved and exact phases, and use the trained ANN to process a test set of retrieved phase maps. The total error in the phase is significantly reduced using this method. We also discuss a variety of potential extensions to this work.
NASA Astrophysics Data System (ADS)
Kang, Yu Jin; Chung, Haegeun; Kim, Min-Seop; Kim, Woong
2015-11-01
We demonstrate the fabrication of high-integrity flexible supercapacitors using carbon nanotubes (CNTs), polyethylene terephthalate (PET) films, and ion gels. Although both CNTs and PET films are attractive materials for flexible electronics, they have poor adhesion properties. In this work, we significantly improve interfacial adhesion by introducing nanostructures at the interface of the CNT and PET layers. Simple reactive ion etching (RIE) of the PET substrates generates nano-scale roughness on the PET surface. RIE also induces hydrophilicity on the PET surface, which further enhances adhesive strength. The improved adhesion enables high integrity and excellent flexibility of the fabricated supercapacitors, demonstrated over hundreds of bending cycles. Furthermore, the supercapacitors show good cyclability with specific capacitance retention of 87.5% after 10,000 galvanostatic charge-discharge (GCD) cycles. Our demonstration may be important for understanding interfacial adhesion properties in nanoscale and for producing flexible, high-integrity, high-performance energy storage systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Ting
The surface morphology of an LED light emitting surface is changed by applying a reactive ion etch (RIE) process to the light emitting surface. High aspect ratio, submicron roughness is formed on the light emitting surface by transferring a thin film metal hard-mask having submicron patterns to the surface prior to applying a reactive ion etch process. The submicron patterns in the metal hard-mask can be formed using a low cost, commercially available nano-patterned template which is transferred to the surface with the mask. After subsequently binding the mask to the surface, the template is removed and the RIE processmore » is applied for time duration sufficient to change the morphology of the surface. The modified surface contains non-symmetric, submicron structures having high aspect ratio which increase the efficiency of the device.« less
Opportunities of CMOS-MEMS integration through LSI foundry and open facility
NASA Astrophysics Data System (ADS)
Mita, Yoshio; Lebrasseur, Eric; Okamoto, Yuki; Marty, Frédéfic; Setoguchi, Ryota; Yamada, Kentaro; Mori, Isao; Morishita, Satoshi; Imai, Yoshiaki; Hosaka, Kota; Hirakawa, Atsushi; Inoue, Shu; Kubota, Masanori; Denoual, Matthieu
2017-06-01
Since the 2000s, several countries have established micro- and nanofabrication platforms for the research and education community as national projects. By combining such platforms with VLSI multichip foundry services, various integrated devices, referred to as “CMOS-MEMS”, can be realized without constructing an entire cleanroom. In this paper, we summarize MEMS-last postprocess schemes for CMOS devices on a bulk silicon wafer as well as on a silicon-on-insulator (SOI) wafer using an open-access cleanroom of the Nanotechnology Platform of MEXT Japan. The integration devices presented in this article are free-standing structures and postprocess isolated LSI devices. Postprocess issues are identified with their solutions, such as the reactive ion etching (RIE) lag for dry release and the impact of the deep RIE (DRIE) postprocess on transistor characteristics. Integration with nonsilicon materials is proposed as one of the future directions.
NASA Astrophysics Data System (ADS)
Zeng, Yu; Fan, Xiaoli; Chen, Jiajia; He, Siyu; Yi, Zao; Ye, Xin; Yi, Yougen
2018-05-01
A silicon substrate with micro-pyramid structure (black silicon) is prepared by wet chemical etching and then subjected to reactive ion etching (RIE) in the mixed gas condition of SF6, CHF3 and He. We systematically study the impacts of flow rates of SF6, CHF3 and He, the etching pressure and the etching time on the surface morphology and reflectivity through various characterizations. Meanwhile, we explore and obtain the optimal combination of parameters for the preparation of composite structure that match the RIE process based on the basis of micro-pyramid silicon substrate. The composite sample prepared under the optimum parameters exhibits excellent anti-reflective performance, hydrophobic, self-cleaning and anti-corrosive properties. Based on the above characteristics, the composite micro/nano structure can be applied to solar cells, photodetectors, LEDs, outdoor devices and other important fields.
NASA Astrophysics Data System (ADS)
Yang, Haoyu; Hattori, Azusa N.; Ohata, Akinori; Takemoto, Shohei; Hattori, Ken; Daimon, Hiroshi; Tanaka, Hidekazu
2017-11-01
A three-dimensional Si{111} vertical side-surface structure on a Si(110) wafer was fabricated by reactive ion etching (RIE) followed by wet-etching and flash-annealing treatments. The side-surface was studied with scanning tunneling microscopy (STM) in atomic scale for the first time, in addition to atomic force microscopy (AFM), scanning electron microscopy (SEM), and low-energy electron diffraction (LEED). AFM and SEM showed flat and smooth vertical side-surfaces without scallops, and STM proved the realization of an atomically-flat 7 × 7-reconstructed structure, under optimized RIE and wet-etching conditions. STM also showed that a step-bunching occurred on the produced {111} side-surface corresponding to a reversely taped side-surface with a tilt angle of a few degrees, but did not show disordered structures. Characteristic LEED patterns from both side- and top-reconstructed surfaces were also demonstrated.
Shallow drilling in the 'Bunte Breccia' impact deposits, Ries Crater, Germany
NASA Technical Reports Server (NTRS)
Hoerz, F.; Gall, H.; Huettner, R.; Oberbeck, V. R.
1977-01-01
The paper is a field report concerning a shallow core drilling program in the multicolored breccia deposits which constitute 90% of all the impact breccias beyond the outer rim of the Ries, a 26-km-diam impact crater. About 480 m of core was recovered from 11 locations with radial ranges between 16.5 and 35 km from the crater center. The cores consist of breccias, whose components are derived from the crater itself and the terrain outside the crater. The local components dominate the breccias at the larger ranges, and possibly constitute more than 90% of the breccia volume at the greatest distances investigated. The great depth of the Bunte Breccia (84 m at 27 km range), together with the preponderance of local components, necessitates an emplacement mechanism that ploughed up and mixed the crater surroundings to depths greater than 50 m.
Fabrication of Cantilever-Bump Type Si Probe Card
NASA Astrophysics Data System (ADS)
Park, Jeong-Yong; Lee, Dong-Seok; Kim, Dong-Kwon; Lee, Jong-Hyun
2000-12-01
Probe card is most important part in the test system which selects the good or bad chip of integrated circuit (IC) chips. Silicon vertical probe card is able to test multiple semiconductor chips simultaneously. We presented cantilever-bump type vertical probe card. It was fabricated by dry etching using RIE(reactive ion etching) technique and porous silicon micromachining using silicon direct bonded (SDB) wafer. Cantilevers and bumps were fabricated by isotropic etching using RIE@. 3-dimensional structures were formed by porous silicon micromachining technique using SDB wafer. Contact resistance of fabricated probe card was less than 2 Ω and its life time was more than 200,000 turns. The process used in this work is very simple and reproducible, which has good controllability in the tip dimension and spacing. It is expected that the fabricated probe card can reduce testing time, can promote productivity and enables burn-in test.
Smith, Herbert L.
2016-01-01
Cet article veut montrer qu’on peut réécrire des modèles démographiques en vue de réaliser des projections par cohorte, en les transposant dans un modèle économétrique vecteur autoré-gressif (VAR). De cette façon, la méthode des composantes se dote d’un cadre stochastique qui étend son envergure. Le potentiel de cette perspective est illustré à travers l’exemple d’une projection d’effectifs de population scolaire. Il met en valeur une série d’équations qui permet de vérifier la validité de plusieurs choix de modélisations habituellement utilisées dans le domaine de la prévision. PMID:27346921
Evolution and characteristics of GaN nanowires produced via maskless reactive ion etching.
Haab, Anna; Mikulics, Martin; Sutter, Eli; Jin, Jiehong; Stoica, Toma; Kardynal, Beata; Rieger, Torsten; Grützmacher, Detlev; Hardtdegen, Hilde
2014-06-27
The formation of nanowires (NWs) by reactive ion etching (RIE) of maskless GaN layers was investigated. The morphological, structural and optical characteristics of the NWs were studied and compared to those of the layer they evolve from. It is shown that the NWs are the result of a defect selective etching process. The evolution of density and length with etching time is discussed. Densely packed NWs with a length of more than 1 μm and a diameter of ∼60 nm were obtained by RIE of a ∼2.5 μm thick GaN layer. The NWs are predominantly free of threading dislocations and show an improvement of optical properties compared to their layer counterpart. The production of NWs via a top down process on non-masked group III-nitride layers is assessed to be very promising for photovoltaic applications.
Études des propriétés électro-optiques d'une série de diphtalocyanines de terres rares
NASA Astrophysics Data System (ADS)
Videlot, C.; Fichou, D.; Garnier, F.
1998-06-01
In this work, we describe the study of photovoltaic cells for a series of rare earth diphthalocyanines. This p type organic compounds have been used in Schottky and pn configurations. Current-voltage curves and action spectra show different replies in energy's conversion according to the rare earth of the diphthalocyanine. Dans ce travail, nous décrivons l'étude de cellules photovoltaïques pour une série de diphtalocyanines de terres rares. Ces composés organiques de type p ont été étudiés dans des configurations Schottky et hétérojonction pn. Les courbes de courant-tension et les spectres d'action montrent des réponses différentes dans la conversion de l'énergie suivant la terre rare de la diphtalocyanine.
Achieving Transformational Materials Performance in a New Era of Science
Sarrao, John
2017-12-22
The inability of current materials to meet performance requirements is a key stumbling block for addressing grand challenges in energy and national security. Fortunately, materials research is on the brink of a new era - a transition from observation and validation of materials properties to prediction and control of materials performance. In this talk, I describe the nature of the current challenge, the prospects for success, and a specific facility concept, MaRIE, that will provide the needed capabilities to meet these challenges, especially for materials in extreme environments. MaRIE, for Matter-Radiation Interactions in Extremes, is Los Alamos' concept to realize this vision of 21st century materials research. This vision will be realized through enhancements to the current LANSCE accelerator, development of a fourth-generation x-ray light source co-located with the proton accelerator, and a comprehensive synthesis and characterization facility focused on controlling complex materials and the defect/structure link to materials performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Li; Gu, Chun; Xu, Lixin, E-mail: xulixin@ustc.edu.cn
The self-adapting algorithms are improved to optimize a beam configuration in the direct drive laser fusion system with the solid state lasers. A configuration of 32 laser beams is proposed for achieving a high uniformity illumination, with a root-mean-square deviation at 10{sup −4} level. In our optimization, the parameters such as beam number, beam arrangement, and beam intensity profile are taken into account. The illumination uniformity robustness versus the parameters such as intensity profile deviations, power imbalance, intensity profile noise, the pointing error, and the target position error is also discussed. In this study, the model is assumed a solid-spheremore » illumination, and refraction effects of incident light on the corona are not considered. Our results may have a potential application in the design of the direct-drive laser fusion of the Shen Guang-II Upgrading facility (SG-II-U, China).« less
Relation of sound intensity and accuracy of localization.
Farrimond, T
1989-08-01
Tests were carried out on 17 subjects to determine the accuracy of monaural sound localization when the head is not free to turn toward the sound source. Maximum accuracy of localization for a constant-volume sound source coincided with the position for maximum perceived intensity of the sound in the front quadrant. There was a tendency for sounds to be perceived more often as coming from a position directly toward the ear. That is, for sounds in the front quadrant, errors of localization tended to be predominantly clockwise (i.e., biased toward a line directly facing the ear). Errors for sounds occurring in the rear quadrant tended to be anticlockwise. The pinna's differential effect on sound intensity between front and rear quadrants would assist in identifying the direction of movement of objects, for example an insect, passing the ear.
Investigation of an Optimum Detection Scheme for a Star-Field Mapping System
NASA Technical Reports Server (NTRS)
Aldridge, M. D.; Credeur, L.
1970-01-01
An investigation was made to determine the optimum detection scheme for a star-field mapping system that uses coded detection resulting from starlight shining through specially arranged multiple slits of a reticle. The computer solution of equations derived from a theoretical model showed that the greatest probability of detection for a given star and background intensity occurred with the use of a single transparent slit. However, use of multiple slits improved the system's ability to reject the detection of undesirable lower intensity stars, but only by decreasing the probability of detection for lower intensity stars to be mapped. Also, it was found that the coding arrangement affected the root-mean-square star-position error and that detection is possible with error in the system's detected spin rate, though at a reduced probability.
Emotion recognition ability in mothers at high and low risk for child physical abuse.
Balge, K A; Milner, J S
2000-10-01
The study sought to determine if high-risk, compared to low-risk, mothers make more emotion recognition errors when they attempt to recognize emotions in children and adults. Thirty-two demographically matched high-risk (n = 16) and low-risk (n = 16) mothers were asked to identify different emotions expressed by children and adults. Sets of high- and low-intensity, visual and auditory emotions were presented. Mothers also completed measures of stress, depression, and ego-strength. High-risk, compared to low-risk, mothers showed a tendency to make more errors on the visual and auditory emotion recognition tasks, with a trend toward more errors on the low-intensity, visual stimuli. However, the observed trends were not significant. Only a post-hoc test of error rates across all stimuli indicated that high-risk, compared to low-risk, mothers made significantly more emotion recognition errors. Although situational stress differences were not found, high-risk mothers reported significantly higher levels of general parenting stress and depression and lower levels of ego-strength. Since only trends and a significant post hoc finding of more overall emotion recognition errors in high-risk mothers were observed, additional research is needed to determine if high-risk mothers have emotion recognition deficits that may impact parent-child interactions. As in prior research, the study found that high-risk mothers reported more parenting stress and depression and less ego-strength.
Psychophysiological Approach To Support Of Cosmonauts Performance Reliability
NASA Astrophysics Data System (ADS)
Nechaev, A. P.
Space flight factors may effect negatively on psychophysiological state (PPS) and work capacity of crewmembers, lead to errors in tasks performance. Such errors cannot be entirely prevented during "crew-spacecraft" system designing and/or crewmembers training as they are consequence of a human "psychophysiological troubles". In the present investigation we paid special attention to work and rest schedule (WRS) intensity due to sleep-wake rhythm disturbances and crewmembers overload may cause PPS aggravation. By methods of the correlation analysis of the data collected during 9 "Mir" missions (18 Russian cosmonauts, 226 flight weeks) the significant (p<0.05) interrelations between WRS intensity and cosmonauts PPS as well as between cosmonauts PPS and crewmembers errors (CE) frequency have been established. It allows to consider WRS intensity as "the controlling factor" in relation to crewmember's PPS. Quantitative characteristics of these interrelations have been also determined. This findings have been used for development of algorithm of crewmember's PPS management with the purpose of decrease in CE frequency. The algorithm can be briefly described in the following kind. On the basis of the analysis of crew forthcoming work experts should assess WRS intensity, possible crewmembers PPS alterations, and expected CE frequency. If CE frequency is allowable the management may be limited to recommendations that operative vigilance increase. If CE frequency is higher allowable it is necessary to carry out the measures on crewmembers PPS normalization by means of decrease in WRS intensity. The algorithm is intended for use in the on-ground expert system of psychophysiological support of cosmonauts performance.
Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nithiananthan, Sajendra; Schafer, Sebastian; Uneri, Ali
2011-04-15
Purpose: A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values (''intensity''). Methods: A variant of the Demons algorithm was developed in which an estimate of the relationship between CT and CBCT intensity values for specific materials in the image is computed at each iteration based on the set of currently overlapping voxels. This tissue-specificmore » intensity correction is then used to estimate the registration output for that iteration and the process is repeated. The robustness of the method was tested in CBCT images of a cadaveric head exhibiting a broad range of simulated intensity variations associated with x-ray scatter, object truncation, and/or errors in the reconstruction algorithm. The accuracy of CT-CBCT registration was also measured in six real cases, exhibiting deformations ranging from simple to complex during surgery or radiotherapy guided by a CBCT-capable C-arm or linear accelerator, respectively. Results: The iterative intensity matching approach was robust against all levels of intensity variation examined, including spatially varying errors in voxel value of a factor of 2 or more, as can be encountered in cases of high x-ray scatter. Registration accuracy without intensity matching degraded severely with increasing magnitude of intensity error and introduced image distortion. A single histogram match performed prior to registration alleviated some of these effects but was also prone to image distortion and was quantifiably less robust and accurate than the iterative approach. Within the six case registration accuracy study, iterative intensity matching Demons reduced mean TRE to (2.5{+-}2.8) mm compared to (3.5{+-}3.0) mm with rigid registration. Conclusions: A method was developed to iteratively correct CT-CBCT intensity disparity during Demons registration, enabling fast, intensity-based registration in CBCT-guided procedures such as surgery and radiotherapy, in which CBCT voxel values may be inaccurate. Accurate CT-CBCT registration in turn facilitates registration of multimodality preoperative image and planning data to intraoperative CBCT by way of the preoperative CT, thereby linking the intraoperative frame of reference to a wealth of preoperative information that could improve interventional guidance.« less
Fast and error-resilient coherent control in an atomic vapor
NASA Astrophysics Data System (ADS)
He, Yizun; Wang, Mengbing; Zhao, Jian; Qiu, Liyang; Wang, Yuzhuo; Fang, Yami; Zhao, Kaifeng; Wu, Saijun
2017-04-01
Nanosecond chirped pulses from an optical arbitrary waveform generator is applied to both invert and coherently split the D1 line population of potassium vapor within a laser focal volume of 2X105 μ m3. The inversion fidelity of f>96%, mainly limited by spontaneous emission during the nanosecond pulse, is inferred from both probe light transmission and superfluorescence emission. The nearly perfect inversion is uniformly achieved for laser intensity varying over an order of magnitude, and is tolerant to detuning error of more than 1000 times the D1 transition linewidth. We further demonstrate enhanced intensity error resilience with multiple chirped pulses and ``universal composite pulses''. This fast and robust coherent control technique should find wide applications in the field of quantum optics, laser cooling, and atom interferometry. This work is supported by National Key Research Program of China under Grant No. 2016YFA0302000, and NNSFC under Grant No. 11574053.
NASA Astrophysics Data System (ADS)
Latzel, M.; Büttner, P.; Sarau, G.; Höflich, K.; Heilmann, M.; Chen, W.; Wen, X.; Conibeer, G.; Christiansen, S. H.
2017-02-01
Nanotextured surfaces provide an ideal platform for efficiently capturing and emitting light. However, the increased surface area in combination with surface defects induced by nanostructuring e.g. using reactive ion etching (RIE) negatively affects the device’s active region and, thus, drastically decreases device performance. In this work, the influence of structural defects and surface states on the optical and electrical performance of InGaN/GaN nanorod (NR) light emitting diodes (LEDs) fabricated by top-down RIE of c-plane GaN with InGaN quantum wells was investigated. After proper surface treatment a significantly improved device performance could be shown. Therefore, wet chemical removal of damaged material in KOH solution followed by atomic layer deposition of only 10 {nm} alumina as wide bandgap oxide for passivation were successfully applied. Raman spectroscopy revealed that the initially compressively strained InGaN/GaN LED layer stack turned into a virtually completely relaxed GaN and partially relaxed InGaN combination after RIE etching of NRs. Time-correlated single photon counting provides evidence that both treatments—chemical etching and alumina deposition—reduce the number of pathways for non-radiative recombination. Steady-state photoluminescence revealed that the luminescent performance of the NR LEDs is increased by about 50% after KOH and 80% after additional alumina passivation. Finally, complete NR LED devices with a suspended graphene contact were fabricated, for which the effectiveness of the alumina passivation was successfully demonstrated by electroluminescence measurements.
Latzel, M; Büttner, P; Sarau, G; Höflich, K; Heilmann, M; Chen, W; Wen, X; Conibeer, G; Christiansen, S H
2017-02-03
Nanotextured surfaces provide an ideal platform for efficiently capturing and emitting light. However, the increased surface area in combination with surface defects induced by nanostructuring e.g. using reactive ion etching (RIE) negatively affects the device's active region and, thus, drastically decreases device performance. In this work, the influence of structural defects and surface states on the optical and electrical performance of InGaN/GaN nanorod (NR) light emitting diodes (LEDs) fabricated by top-down RIE of c-plane GaN with InGaN quantum wells was investigated. After proper surface treatment a significantly improved device performance could be shown. Therefore, wet chemical removal of damaged material in KOH solution followed by atomic layer deposition of only 10 [Formula: see text] alumina as wide bandgap oxide for passivation were successfully applied. Raman spectroscopy revealed that the initially compressively strained InGaN/GaN LED layer stack turned into a virtually completely relaxed GaN and partially relaxed InGaN combination after RIE etching of NRs. Time-correlated single photon counting provides evidence that both treatments-chemical etching and alumina deposition-reduce the number of pathways for non-radiative recombination. Steady-state photoluminescence revealed that the luminescent performance of the NR LEDs is increased by about 50% after KOH and 80% after additional alumina passivation. Finally, complete NR LED devices with a suspended graphene contact were fabricated, for which the effectiveness of the alumina passivation was successfully demonstrated by electroluminescence measurements.
Simulation of wave propagation in three-dimensional random media
NASA Astrophysics Data System (ADS)
Coles, Wm. A.; Filice, J. P.; Frehlich, R. G.; Yadlowsky, M.
1995-04-01
Quantitative error analyses for the simulation of wave propagation in three-dimensional random media, when narrow angular scattering is assumed, are presented for plane-wave and spherical-wave geometry. This includes the errors that result from finite grid size, finite simulation dimensions, and the separation of the two-dimensional screens along the propagation direction. Simple error scalings are determined for power-law spectra of the random refractive indices of the media. The effects of a finite inner scale are also considered. The spatial spectra of the intensity errors are calculated and compared with the spatial spectra of
NASA Astrophysics Data System (ADS)
Kaminski, Michael; Kaka, SanLinn; Kaminski, Matthew
2017-04-01
The hypervelocity impact of an asteroid in southern Germany around 15 million years ago not only caused an environmental catastrophe, but it also created a scenario that provides us with a world-class natural laboratory for teaching the basic Principles of Geology. The combination of museum visits and observation of rock outcrops enables the student to reinforce or rediscover the basic principles of physical and historical Geology that are presented in first- or second-year Geoscience courses. At KFUPM, our visit to the Ries Geopark begins at the Ries Crater Museum in Nördlingen, where students review knowledge learned in their Physical Geology course: the Nebular Theory, origin of the solar system, and the classification of meteorites based on real examples. Students then learn the stages of impact crater formation, shock metamorphism, and the products of impact crater formation such as tectites, impact breccia and suevite. Students also become familiar with the Mesozoic stratigraphy of Southern Germany, reviewing basic principals of stratigraphy. Visits to local outcrops reinforce the knowledge gained at the Museum. A visit to the nearby Solnhofen Museum and quarries provides insight into the nature of the late Jurassic animals that lived at the edge of the Tethys Sea, reinforcing many topics learned during their second-year Paleontology course, such as taphonomy, and the idea of a death assemblage. At the Museum of the Geosciences Department of the University of Tübingen, the students become familiar with Mesozoic ammonoids as part of their second-year Paleontology course. A visit to the Urwelt Museum and quarry in Holzmaden explores animal life during the Early Jurassic, stratigraphic principles as presented on the museum's "geological staircase", and the origin of petroleum source rocks. The museum houses spectacular examples of Early Jurassic marine reptiles. All knowledge gained in the Jurassic of southern Germany enriches the students' understanding of the Jurassic subsurface petroleum system in Saudi Arabia, which is one of the world's largest petroleum reservoirs. The combination of museum visits followed by field studies centered around the Ries Geopark in southern Germany not only creates a world-class attraction for Geotourists, but also an ideal teaching laboratory for students interested in Physical and Planetary Geology, Historical Geology, and Paleontology at various levels within the respective subjects.
After the Medication Error: Recent Nursing Graduates' Reflections on Adequacy of Education.
Treiber, Linda A; Jones, Jackie H
2018-05-01
The purpose of this study was to better understand individual- and system-level factors surrounding making a medication error from the perspective of recent Bachelor of Science in Nursing graduates. Online survey mixed-methods items included perceptions of adequacy of preparatory nursing education, contributory variables, emotional responses, and treatment by employer following the error. Of the 168 respondents, 55% had made a medication error. Errors resulted from inexperience, rushing, technology, staffing, and patient acuity. Twenty-four percent did not report their errors. Key themes for improving education included more practice in varied clinical areas, intensive pharmacological preparation, practical instruction in functioning within the health care environment, and coping after making medication errors. Errors generally caused emotional distress in the error maker. Overall, perceived treatment after the error reflected supportive environments, where nurses were generally treated with respect, fair treatment, and understanding. Opportunities for nursing education include second victim awareness and reinforcing professional practice standards. [J Nurs Educ. 2018;57(5):275-280.]. Copyright 2018, SLACK Incorporated.
Mean Bias in Seasonal Forecast Model and ENSO Prediction Error.
Kim, Seon Tae; Jeong, Hye-In; Jin, Fei-Fei
2017-07-20
This study uses retrospective forecasts made using an APEC Climate Center seasonal forecast model to investigate the cause of errors in predicting the amplitude of El Niño Southern Oscillation (ENSO)-driven sea surface temperature variability. When utilizing Bjerknes coupled stability (BJ) index analysis, enhanced errors in ENSO amplitude with forecast lead times are found to be well represented by those in the growth rate estimated by the BJ index. ENSO amplitude forecast errors are most strongly associated with the errors in both the thermocline slope response and surface wind response to forcing over the tropical Pacific, leading to errors in thermocline feedback. This study concludes that upper ocean temperature bias in the equatorial Pacific, which becomes more intense with increasing lead times, is a possible cause of forecast errors in the thermocline feedback and thus in ENSO amplitude.
Buchini, Sara; Quattrin, Rosanna
2012-04-01
To record the frequency of interruptions and their causes, to identify 'avoidable' interruptions and to build an improvement project to reduce 'avoidable' interruptions. In Italy each year 30,000-35,000 deaths per year are attributed to health-care system errors, of which 19% are caused by medication errors. The factors that contribute to drug management error also include interruptions and carelessness during treatment administration. A descriptive study design was used to record the frequency of interruptions and their causes and to identify 'avoidable' interruptions in an intensive rehabilitation ward in Northern Italy. A data collection grid was used to record the data over a 6-month period. A total of 3000 work hours were observed. During the study period 1170 interruptions were observed. The study identified 14 causes of interruption. The study shows that of the 14 cases of interruptions at least nine can be defined as 'avoidable'. An improvement project has been proposed to reduce unnecessary interruptions and distractions to avoid making errors. An additional useful step to reduce the incidence of treatment errors would be to implement the use of a single patient medication sheet for the recording of drug prescription, preparation and administration and also the incident reporting. © 2011 Blackwell Publishing Ltd.
Tan, Bing; Huang, Min; Zhu, Qibing; Guo, Ya; Qin, Jianwei
2017-09-01
The laser induced breakdown spectroscopy (LIBS) technique is an effective method to detect material composition by obtaining the plasma emission spectrum. The overlapping peaks in the spectrum are a fundamental problem in the qualitative and quantitative analysis of LIBS. Based on a curve fitting method, this paper studies an error compensation method to achieve the decomposition and correction of overlapping peaks. The vital step is that the fitting residual is fed back to the overlapping peaks and performs multiple curve fitting processes to obtain a lower residual result. For the quantitative experiments of Cu, the Cu-Fe overlapping peaks in the range of 321-327 nm obtained from the LIBS spectrum of five different concentrations of CuSO 4 ·5H 2 O solution were decomposed and corrected using curve fitting and error compensation methods. Compared with the curve fitting method, the error compensation reduced the fitting residual about 18.12-32.64% and improved the correlation about 0.86-1.82%. Then, the calibration curve between the intensity and concentration of the Cu was established. It can be seen that the error compensation method exhibits a higher linear correlation between the intensity and concentration of Cu, which can be applied to the decomposition and correction of overlapping peaks in the LIBS spectrum.
Echeta, Genevieve; Moffett, Brady S; Checchia, Paul; Benton, Mary Kay; Klouda, Leda; Rodriguez, Fred H; Franklin, Wayne
2014-01-01
Adults with congenital heart disease (CHD) are often cared for at pediatric hospitals. There are no data describing the incidence or type of medication prescribing errors in adult patients admitted to a pediatric cardiovascular intensive care unit (CVICU). A review of patients >18 years of age admitted to the pediatric CVICU at our institution from 2009 to 2011 occurred. A comparator group <18 years of age but >70 kg (a typical adult weight) was identified. Medication prescribing errors were determined according to a commonly used adult drug reference. An independent panel consisting of a physician specializing in the care of adult CHD patients, a nurse, and a pharmacist evaluated all errors. Medication prescribing orders were classified as appropriate, underdose, overdose, or nonstandard (dosing per weight instead of standard adult dosing), and severity of error was classified. Eighty-five adult (74 patients) and 33 pediatric admissions (32 patients) met study criteria (mean age 27.5 ± 9.4 years, 53% male vs. 14.9 ± 1.8 years, 63% male). A cardiothoracic surgical procedure occurred in 81.4% of admissions. Adult admissions weighed less than pediatric admissions (72.8 ± 22.4 kg vs. 85.6 ± 14.9 kg, P < .01) but hospital length of stay was similar. (Adult 6 days [range 1-216 days]; pediatric 5 days [Range 2-123 days], P = .52.) A total of 112 prescribing errors were identified and they occurred less often in adults (42.4% of admissions vs. 66.7% of admissions, P = .02). Adults had a lower mean number of errors (0.7 errors per adult admission vs. 1.7 errors per pediatric admission, P < .01). Prescribing errors occurred most commonly with antimicrobials (n = 27). Underdosing was the most common category of prescribing error. Most prescribing errors were determined to have not caused harm to the patient. Prescribing errors occur frequently in adult patients admitted to a pediatric CVICU but occur more often in pediatric patients of adult weight. © 2013 Wiley Periodicals, Inc.
Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach
Nithiananthan, Sajendra; Schafer, Sebastian; Uneri, Ali; Mirota, Daniel J.; Stayman, J. Webster; Zbijewski, Wojciech; Brock, Kristy K.; Daly, Michael J.; Chan, Harley; Irish, Jonathan C.; Siewerdsen, Jeffrey H.
2011-01-01
Purpose: A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values (“intensity”). Methods: A variant of the Demons algorithm was developed in which an estimate of the relationship between CT and CBCT intensity values for specific materials in the image is computed at each iteration based on the set of currently overlapping voxels. This tissue-specific intensity correction is then used to estimate the registration output for that iteration and the process is repeated. The robustness of the method was tested in CBCT images of a cadaveric head exhibiting a broad range of simulated intensity variations associated with x-ray scatter, object truncation, and∕or errors in the reconstruction algorithm. The accuracy of CT-CBCT registration was also measured in six real cases, exhibiting deformations ranging from simple to complex during surgery or radiotherapy guided by a CBCT-capable C-arm or linear accelerator, respectively. Results: The iterative intensity matching approach was robust against all levels of intensity variation examined, including spatially varying errors in voxel value of a factor of 2 or more, as can be encountered in cases of high x-ray scatter. Registration accuracy without intensity matching degraded severely with increasing magnitude of intensity error and introduced image distortion. A single histogram match performed prior to registration alleviated some of these effects but was also prone to image distortion and was quantifiably less robust and accurate than the iterative approach. Within the six case registration accuracy study, iterative intensity matching Demons reduced mean TRE to (2.5±2.8) mm compared to (3.5±3.0) mm with rigid registration. Conclusions: A method was developed to iteratively correct CT-CBCT intensity disparity during Demons registration, enabling fast, intensity-based registration in CBCT-guided procedures such as surgery and radiotherapy, in which CBCT voxel values may be inaccurate. Accurate CT-CBCT registration in turn facilitates registration of multimodality preoperative image and planning data to intraoperative CBCT by way of the preoperative CT, thereby linking the intraoperative frame of reference to a wealth of preoperative information that could improve interventional guidance. PMID:21626913
[Phenylephrine dosing error in Intensive Care Unit. Case of the trimester].
2013-01-01
A real clinical case reported to SENSAR is presented. A patient admitted to the surgical intensive care unit following a lung resection, suffered arterial hypotension. The nurse was asked to give the patient 1 mL of phenylephrine. A few seconds afterwards, the patient experienced a hypertensive crisis, which resolved spontaneously without damage. Thereafter, the nurse was interviewed and a dosing error was identified: she had mistakenly given the patient 1 mg of phenylephrine (1 mL) instead of 100 mcg (1 mL of the standard dilution, 1mg in 10 mL). The incident analysis revealed latent factors (event triggers) due to the lack of protocols and standard operating procedures, communication errors among team members (physician-nurse), suboptimal training, and underdeveloped safety culture. In order to preempt similar incidents in the future, the following actions were implemented in the surgical intensive care unit: a protocol for bolus and short lived infusions (<30 min) was developed and to close the communication gap through the adoption of communication techniques. The protocol was designed by physicians and nurses to standardize the administration of drugs with high potential for errors. To close the communication gap, repeated checks about saying and understanding was proposed ("closed loop"). Labeling syringes with the drug dilution was also recommended. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
Dinges, Eric; Felderman, Nicole; McGuire, Sarah; Gross, Brandie; Bhatia, Sudershan; Mott, Sarah; Buatti, John; Wang, Dongxu
2015-01-01
Background and Purpose This study evaluates the potential efficacy and robustness of functional bone marrow sparing (BMS) using intensity-modulated proton therapy (IMPT) for cervical cancer, with the goal of reducing hematologic toxicity. Material and Methods IMPT plans with prescription dose of 45 Gy were generated for ten patients who have received BMS intensity-modulated x-ray therapy (IMRT). Functional bone marrow was identified by 18F-flourothymidine positron emission tomography. IMPT plans were designed to minimize the volume of functional bone marrow receiving 5–40 Gy while maintaining similar target coverage and healthy organ sparing as IMRT. IMPT robustness was analyzed with ±3% range uncertainty errors and/or ±3mm translational setup errors in all three principal dimensions. Results In the static scenario, the median dose volume reductions for functional bone marrow by IMPT were: 32% for V5GY, 47% for V10Gy, 54% for V20Gy, and 57% for V40Gy, all with p<0.01 compared to IMRT. With assumed errors, even the worst-case reductions by IMPT were: 23% for V5Gy, 37% for V10Gy, 41% for V20Gy, and 39% for V40Gy, all with p<0.01. Conclusions The potential sparing of functional bone marrow by IMPT for cervical cancer is significant and robust under realistic systematic range uncertainties and clinically relevant setup errors. PMID:25981130
Wireless clinical alerts and patient outcomes in the surgical intensive care unit.
Major, Kevin; Shabot, M Michael; Cunneen, Scott
2002-12-01
Errors in medicine have gained public interest since the Institute of Medicine published its 1999 report on this subject. Although errors of commission are frequently cited, errors of omission can be equally serious. A computerized surgical intensive care unit (SICU) information system when coupled to an event-driven alerting engine has the potential to reduce errors of omission for critical intensive care unit events. Automated alerts and patient outcomes were prospectively collected for all patients admitted to a tertiary-care SICU for a 2-year period. During the study period 3,973 patients were admitted to the SICU and received 13,608 days of care. A total of 15,066 alert pages were sent including alerts for physiologic condition (6,163), laboratory data (4,951), blood gas (3,774), drug allergy (130), and toxic drug levels (48). Admission Simplified Acute Physiology Score and Acute Physiology and Chronic Health Evaluation II score, SICU lengths of stay, and overall mortality rates were significantly higher in patients who triggered the alerting system. Patients triggering the alert paging system were 49.4 times more likely to die in the SICU compared with patients who did not generate an alert. Even after transfer to floor care the patients who triggered the alerting system were 5.7 times more likely to die in the hospital. An alert page identifies patients who will stay in the SICU longer and have a significantly higher chance of death compared with patients who do not trigger the alerting system.
NASA Astrophysics Data System (ADS)
Zhou, Yanru; Zhao, Yuxiang; Tian, Hui; Zhang, Dengwei; Huang, Tengchao; Miao, Lijun; Shu, Xiaowu; Che, Shuangliang; Liu, Cheng
2016-12-01
In an axial magnetic field (AMF), which is vertical to the plane of the fiber coil, a polarization-maintaining fiber optic gyro (PM-FOG) appears as an axial magnetic error. This error is linearly related to the intensity of an AMF, the radius of the fiber coil, and the light wavelength, and also influenced by the distribution of fiber twist. When a PM-FOG is manufactured completely, this error only appears a linear correlation with the AMF. A real-time compensation model is established to eliminate the error, and the experimental results show that the axial magnetic error of the PM-FOG is decreased from 5.83 to 0.09 deg/h in 12G AMF with 18-dB suppression.
Donn, Steven M; McDonnell, William M
2012-01-01
The Institute of Medicine has recommended a change in culture from "name and blame" to patient safety. This will require system redesign to identify and address errors, establish performance standards, and set safety expectations. This approach, however, is at odds with the present medical malpractice (tort) system. The current system is outcomes-based, meaning that health care providers and institutions are often sued despite providing appropriate care. Nevertheless, the focus should remain to provide the safest patient care. Effective peer review may be hindered by the present tort system. Reporting of medical errors is a key piece of peer review and education, and both anonymous reporting and confidential reporting of errors have potential disadvantages. Diagnostic and treatment errors continue to be the leading sources of allegations of malpractice in pediatrics, and the neonatal intensive care unit is uniquely vulnerable. Most errors result from systems failures rather than human error. Risk management can be an effective process to identify, evaluate, and address problems that may injure patients, lead to malpractice claims, and result in financial losses. Risk management identifies risk or potential risk, calculates the probability of an adverse event arising from a risk, estimates the impact of the adverse event, and attempts to control the risk. Implementation of a successful risk management program requires a positive attitude, sufficient knowledge base, and a commitment to improvement. Transparency in the disclosure of medical errors and a strategy of prospective risk management in dealing with medical errors may result in a substantial reduction in medical malpractice lawsuits, lower litigation costs, and a more safety-conscious environment. Thieme Medical Publishers, Inc.
The Role of Extensive Recasts in Error Detection and Correction by Adult ESL Students
ERIC Educational Resources Information Center
Hawkes, Laura; Nassaji, Hossein
2016-01-01
Most of the laboratory studies on recasts have examined the role of intensive recasts provided repeatedly on the same target structure. This is different from the original definition of recasts as the reformulation of learner errors as they occur naturally and spontaneously in the course of communicative interaction. Using a within-group research…
Morphological Errors in Spanish Second Language Learners and Heritage Speakers
ERIC Educational Resources Information Center
Montrul, Silvina
2011-01-01
Morphological variability and the source of these errors have been intensely debated in SLA. A recurrent finding is that postpuberty second language (L2) learners often omit or use the wrong affix for nominal and verbal inflections in oral production but less so in written tasks. According to the missing surface inflection hypothesis, L2 learners…
NASA Astrophysics Data System (ADS)
Krupka, M.; Kalal, M.; Dostal, J.; Dudzak, R.; Juha, L.
2017-08-01
Classical interferometry became widely used method of active optical diagnostics. Its more advanced version, allowing reconstruction of three sets of data from just one especially designed interferogram (so called complex interferogram) was developed in the past and became known as complex interferometry. Along with the phase shift, which can be also retrieved using classical interferometry, the amplitude modifications of the probing part of the diagnostic beam caused by the object under study (to be called the signal amplitude) as well as the contrast of the interference fringes can be retrieved using the complex interferometry approach. In order to partially compensate for errors in the reconstruction due to imperfections in the diagnostic beam intensity structure as well as for errors caused by a non-ideal optical setup of the interferometer itself (including the quality of its optical components), a reference interferogram can be put to a good use. This method of interferogram analysis of experimental data has been successfully implemented in practice. However, in majority of interferometer setups (especially in the case of the ones employing the wavefront division) the probe and the reference part of the diagnostic beam would feature different intensity distributions over their respective cross sections. This introduces additional error into the reconstruction of the signal amplitude and the fringe contrast, which cannot be resolved using the reference interferogram only. In order to deal with this error it was found that additional separately recorded images of the intensity distribution of the probe and the reference part of the diagnostic beam (with no signal present) are needed. For the best results a sufficient shot-to-shot stability of the whole diagnostic system is required. In this paper, efficiency of the complex interferometry approach for obtaining the highest possible accuracy of the signal amplitude reconstruction is verified using the computer generated complex and reference interferograms containing artificially introduced intensity variations in the probe and the reference part of the diagnostic beam. These sets of data are subsequently analyzed and the errors of the signal amplitude reconstruction are evaluated.
Line Intensities in the ν 8Band of HNO 3
NASA Astrophysics Data System (ADS)
Wang, W. F.; Looi, E. C.; Tan, T. L.; Ong, P. P.
1996-07-01
Line intensity measurements have been made on the ν 8band of HNO 3using a high-resolution Fourier transform infrared spectrum in the region 739-800 cm -1. A least-squares fit of a total of 710 line intensities in the Pand Rbranches was performed, leading to accurate determination of five dipole moment operator constants. By utilizing these constants, the observed line intensities are well reproduced with an average random error of 6% and the integrated band intensity is found to be 15.7 ± 0.9 cm -2atm -1at 296 K.
Silva, Arnaldo F; Richter, Wagner E; Meneses, Helen G C; Bruns, Roy E
2014-11-14
Atomic charge transfer-counter polarization effects determine most of the infrared fundamental CH intensities of simple hydrocarbons, methane, ethylene, ethane, propyne, cyclopropane and allene. The quantum theory of atoms in molecules/charge-charge flux-dipole flux model predicted the values of 30 CH intensities ranging from 0 to 123 km mol(-1) with a root mean square (rms) error of only 4.2 km mol(-1) without including a specific equilibrium atomic charge term. Sums of the contributions from terms involving charge flux and/or dipole flux averaged 20.3 km mol(-1), about ten times larger than the average charge contribution of 2.0 km mol(-1). The only notable exceptions are the CH stretching and bending intensities of acetylene and two of the propyne vibrations for hydrogens bound to sp hybridized carbon atoms. Calculations were carried out at four quantum levels, MP2/6-311++G(3d,3p), MP2/cc-pVTZ, QCISD/6-311++G(3d,3p) and QCISD/cc-pVTZ. The results calculated at the QCISD level are the most accurate among the four with root mean square errors of 4.7 and 5.0 km mol(-1) for the 6-311++G(3d,3p) and cc-pVTZ basis sets. These values are close to the estimated aggregate experimental error of the hydrocarbon intensities, 4.0 km mol(-1). The atomic charge transfer-counter polarization effect is much larger than the charge effect for the results of all four quantum levels. Charge transfer-counter polarization effects are expected to also be important in vibrations of more polar molecules for which equilibrium charge contributions can be large.
Analysis of Fragmentation During Dynamic Loading: Investigations in the Ries Impact Crater, Germany
NASA Astrophysics Data System (ADS)
Weimer, D.; Hergarten, S.; Kenkmann, T.
2015-09-01
We tested three methods to quantify fragmentation of rocks during dynamic loading and found a trend of decreasing fracture density with increasing distance from crater center. Fragmentation attenuation rates in the near- and far-field are different.
Résultats fonctionnels des lésions des tendons fléchisseurs de la main: à propos de 90 cas
Boussakri, Hassan; Azarkane, Mohamad; Elidrissi, Mohamad; Shimi, Mohamad; Elibrahimi, Abdelhalim; Elmrini, Abdelmajid
2013-01-01
Les auteurs rapportent une série de 90 patients, présentant une section tendineuse des fléchisseurs de la main, et suivis avec un recul moyen de 8 mois (min: 2 mois; max: 13 mois). La lésion était localisée dans 12% des cas en zone I, 46% des cas en zone II, 2% en zone III et 25% des cas en zone IV et V. Pour le pouce (13 patients), 10 cas en zone T2 et 3 cas en zone T3. La technique opératoire utilisée était les sutures tendineuses en cadre de Kessler modifié, associée à un surjet épitendineux. Nous avons obtenus 54% de très bons résultats, 34% de résultats moyens et 12% de mauvais résultats. Pour le pouce les résultats semble moins bons avec un taux de résultats médiocre de 48%. Certes les chiffres de cette série sont moins bons que ceux des autres séries publiées dans la littérature. Les facteurs influençant les résultats sont d'abord l'utilisation d'immobilisation postopératoire systématique ainsi que le mécanisme d'agression, et la localisation à la zone II et au pouce. Les complications mécaniques sont représentées par 7% de rupture, toutes au niveau de pouce, et 31% des adhérences tendineuses (soit 30 cas), dont 19 en zone II, l'infections (22%) et 4% des cas d'algodystrophies. PMID:23847698
NASA Astrophysics Data System (ADS)
Watanabe, Tsuyoshi; Taniguchi, Kazutake; Suzuki, Kouta; Iyama, Hiromasa; Kishimoto, Shuji; Sato, Takashi; Kobayashi, Hideo
2016-06-01
Fine hole and dot patterns with bit pitches (bp’s) of less than 40 nm were fabricated in the circular band area of a quartz substrate by R-θ electron beam lithography (EBL), reactive ion etching (RIE), and nanoimprinting. These patterning processes were studied to obtain minimum pitch sizes of hole and dot patterns without pattern collapse. The patterning on the circular band was aimed to apply these patterning processes to future high-density bit-patterned media (BPM) for hard disk drive (HDD) and permanent memory for the long life archiving of digital data. In hole patterning, a minimum-22-nm-bp and 8.2-nm-diameter pattern (1.3 Tbit/in.2) was obtained on a quartz substrate by optimizing the R-θ EBL and RIE processes. Dot patterns were replicated on another quartz substrate by nanoimprinting using a hole-patterned quartz substrate as a master mold followed by RIE. In dot patterning, a minimum-30-nm-bp and 18.5-nm-diameter pattern (0.7 Tbit/in.2) was obtained by introducing new descum conditions. It was observed that the minimum bp of successful patterning increased as the fabrication process proceeded, i.e., from 20 nm bp in the first EBL process to 30 nm bp in the last quartz dot patterning process. From the measured diameters of the patterns, it was revealed that pattern collapse was apt to occur when the value of average diameter plus 3 sigma of diameter was close to the bp. It was suggested that multiple fabrication processes caused the degradation of pattern quality; therefore, hole patterning is more suitable than dot patterning for future applications owing to the lower quality degradation by its simple fabrication process.
Njall, Clotilde; Adiogo, Dieudonné; Bita, André; Ateba, Noel; Sume, Gérald; Kollo, Basile; Binam, Fidèle; Tchoua, Romain
2013-01-01
Introduction L'objectif principal de notre étude était d'identifier les bactéries associées à l'infection nosocomiale, dans le service de réanimation, de l'hôpital Laquintinie de Douala en vue d'améliorer la prise en charge et diminuer la létalité. Méthodes Il s'agissait d'une étude transversale et descriptive, menée du 1er mars au 31 mai 2011.Tous les patients hospitalisés depuis au moins 48 h étaient inclus dans l’étude et ceux présentant une infection documentée à l'admission étaient exclus. L'analyse des donnés a été faite par le logiciel SPSS 16.Les tests de Khi deux pour la signification. Résultats La prévalence de l'infection nosocomiale était de 12%, elle concernait des personnes âgées de plus de 60 ans et présentant une infection urinaire dans 79% des cas. La létalité était de 72% pour une durée moyenne de séjour de 11,7 ± 12,1 jours. Les bactéries responsables étaient en majorité des bactéries gram positifs (BGN), dont E coli dans 23,1% et les cocci gram positifs(CGP), dans 15,4% des cas. Conclusion L’étude de la résistance aux antibiotiques, montre une multi résistance, dont il faut tenir compte en mettant en place une stratégie de prévention active. PMID:23785545
USDA-ARS?s Scientific Manuscript database
Three different models of tipping bucket rain gauges (TBRs), viz. HS-TB3 (Hydrological Services Pty Ltd), ISCO-674 (Isco, Inc.) and TR-525 (Texas Electronics, Inc.), were calibrated in the lab to quantify measurement errors across a range of rainfall intensities (5 mm.h-1 to 250 mm.h-1) and three di...
Fault-Tolerant Computing: An Overview
1991-06-01
Addison Wesley:, Reading, MA) 1984. [8] J. Wakerly , Error Detecting Codes, Self-Checking Circuits and Applications , (Elsevier North Holland, Inc.- New York... applicable to bit-sliced organi- zations of hardware. In the first time step, the normal computation is performed on the operands and the results...for error detection and fault tolerance in parallel processor systems while perform- ing specific computation-intensive applications [111. Contrary to
Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar.
Li, Zhan; Jupp, David L B; Strahler, Alan H; Schaaf, Crystal B; Howe, Glenn; Hewawasam, Kuravi; Douglas, Ewan S; Chakrabarti, Supriya; Cook, Timothy A; Paynter, Ian; Saenz, Edward J; Schaefer, Michael
2016-03-02
Radiometric calibration of the Dual-Wavelength Echidna(®) Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρ(app)), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρ(app) are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρ(app) error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρ(app) from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars.
Spectroscopic ellipsometer based on direct measurement of polarization ellipticity.
Watkins, Lionel R
2011-06-20
A polarizer-sample-Wollaston prism analyzer ellipsometer is described in which the ellipsometric angles ψ and Δ are determined by direct measurement of the elliptically polarized light reflected from the sample. With the Wollaston prism initially set to transmit p- and s-polarized light, the azimuthal angle P of the polarizer is adjusted until the two beams have equal intensity. This condition yields ψ=±P and ensures that the reflected elliptically polarized light has an azimuthal angle of ±45° and maximum ellipticity. Rotating the Wollaston prism through 45° and adjusting the analyzer azimuth until the two beams again have equal intensity yields the ellipticity that allows Δ to be determined via a simple linear relationship. The errors produced by nonideal components are analyzed. We show that the polarizer dominates these errors but that for most practical purposes, the error in ψ is negligible and the error in Δ may be corrected exactly. A native oxide layer on a silicon substrate was measured at a single wavelength and multiple angles of incidence and spectroscopically at a single angle of incidence. The best fit film thicknesses obtained were in excellent agreement with those determined using a traditional null ellipsometer.
Koren, Katja; Pišot, Rado; Šimunič, Boštjan
2016-05-01
To determine the effects of a moderate-intensity active workstation on time and error during simulated office work. The aim of the study was to analyse simultaneous work and exercise for non-sedentary office workers. We monitored oxygen uptake, heart rate, sweating stains area, self-perceived effort, typing test time with typing error count and cognitive performance during 30 min of exercise with no cycling or cycling at 40 and 80 W. Compared baseline, we found increased physiological responses at 40 and 80 W, which corresponds to moderate physical activity (PA). Typing time significantly increased by 7.3% (p = 0.002) in C40W and also by 8.9% (p = 0.011) in C80W. Typing error count and cognitive performance were unchanged. Although moderate intensity exercise performed on cycling workstation during simulated office tasks increases working task execution time with, it has moderate effect size; however, it does not increase the error rate. Participants confirmed that such a working design is suitable for achieving the minimum standards for daily PA during work hours. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Analysis of Sources of Large Positioning Errors in Deterministic Fingerprinting
2017-01-01
Wi-Fi fingerprinting is widely used for indoor positioning and indoor navigation due to the ubiquity of wireless networks, high proliferation of Wi-Fi-enabled mobile devices, and its reasonable positioning accuracy. The assumption is that the position can be estimated based on the received signal strength intensity from multiple wireless access points at a given point. The positioning accuracy, within a few meters, enables the use of Wi-Fi fingerprinting in many different applications. However, it has been detected that the positioning error might be very large in a few cases, which might prevent its use in applications with high accuracy positioning requirements. Hybrid methods are the new trend in indoor positioning since they benefit from multiple diverse technologies (Wi-Fi, Bluetooth, and Inertial Sensors, among many others) and, therefore, they can provide a more robust positioning accuracy. In order to have an optimal combination of technologies, it is crucial to identify when large errors occur and prevent the use of extremely bad positioning estimations in hybrid algorithms. This paper investigates why large positioning errors occur in Wi-Fi fingerprinting and how to detect them by using the received signal strength intensities. PMID:29186921
Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar
Li, Zhan; Jupp, David L. B.; Strahler, Alan H.; Schaaf, Crystal B.; Howe, Glenn; Hewawasam, Kuravi; Douglas, Ewan S.; Chakrabarti, Supriya; Cook, Timothy A.; Paynter, Ian; Saenz, Edward J.; Schaefer, Michael
2016-01-01
Radiometric calibration of the Dual-Wavelength Echidna® Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρapp), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρapp are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρapp error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρapp from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars. PMID:26950126
Müller, Rachel; Terrill, Alexandra L; Jensen, Mark P; Molton, Ivan R; Ravesloot, Craig; Ipsen, Catherine
2015-12-01
The aim of this study was to examine how the construct of happiness is related to pain intensity, pain interference, and distress in individuals with physical disabilities. This study involves cross-sectional analyses of 471 individuals with a variety of health conditions reporting at least mild pain. The first hypothesis that happiness mediates the relationship between pain intensity and two outcomes, pain interference and distress, was not supported. The second hypothesis was supported by a good fitting model (χ2(10) = 12.83, P = 0.23, root-mean-square error of approximation = 0.025) and indicated that pain intensity significantly mediated the effect of happiness on pain interference (indirect effect: β = -0.13, P < 0.001) and on distress (indirect effect: β = 0.10, P = 0.01). Happiness showed a significant direct effect on pain intensity (β = -0.20, P < 0.001). A third model exploring the happiness components meaning, pleasure, and engagement fitted well (χ2(4) = 9.65, P = 0.05, root-mean-square error of approximation = 0.055). Pain intensity acted as a significant mediator but only mediated the effect of meaning on pain interference (indirect effect: β = -0.07, P = 0.05) and on distress (indirect effect via pain interference: β = -0.04, P = 0.05). Only meaning (β = -0.10, P = 0.05), but neither pleasure nor engagement, had a significant direct effect on pain intensity. Participants who reported greater happiness reported lower pain interference and distress through happiness' effects on pain intensity. Experiencing meaning and purpose in life seems to be most closely (and negatively) associated with pain intensity, pain interference, and distress. Findings from this study can lay the groundwork for intervention studies to better understand how to more effectively decrease pain intensity, pain interference, and distress.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yueqi; Lava, Pascal; Reu, Phillip
This study presents a theoretical uncertainty quantification of displacement measurements by subset-based 2D-digital image correlation. A generalized solution to estimate the random error of displacement measurement is presented. The obtained solution suggests that the random error of displacement measurements is determined by the image noise, the summation of the intensity gradient in a subset, the subpixel part of displacement, and the interpolation scheme. The proposed method is validated with virtual digital image correlation tests.
Wang, Yueqi; Lava, Pascal; Reu, Phillip; ...
2015-12-23
This study presents a theoretical uncertainty quantification of displacement measurements by subset-based 2D-digital image correlation. A generalized solution to estimate the random error of displacement measurement is presented. The obtained solution suggests that the random error of displacement measurements is determined by the image noise, the summation of the intensity gradient in a subset, the subpixel part of displacement, and the interpolation scheme. The proposed method is validated with virtual digital image correlation tests.
The Goal-Means (GM) Meta Model
2009-05-01
WORK UNIT NUMBER 15 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) National Security Innovations, Inc. 8 Faneuil Hall Marketplace Boston...MA 02109 8. PERFORMING ORGANIZATION REPORT NUMBER N/A 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) AFRL/RIED 525...many different performers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dr. Donald Rej
Dr. Donald Rej of Los Alamos National Laboratory presents an overview of issues, needs, and performance gaps related to materials testing and how they are being addressed at their facility. Current projects such as the Los Alamos Neutron Science Center (LANSCE) and Matter-Radiation Interactions in Extremes (MaRIE) are also discussed.
Registration of 2D to 3D joint images using phase-based mutual information
NASA Astrophysics Data System (ADS)
Dalvi, Rupin; Abugharbieh, Rafeef; Pickering, Mark; Scarvell, Jennie; Smith, Paul
2007-03-01
Registration of two dimensional to three dimensional orthopaedic medical image data has important applications particularly in the area of image guided surgery and sports medicine. Fluoroscopy to computer tomography (CT) registration is an important case, wherein digitally reconstructed radiographs derived from the CT data are registered to the fluoroscopy data. Traditional registration metrics such as intensity-based mutual information (MI) typically work well but often suffer from gross misregistration errors when the image to be registered contains a partial view of the anatomy visible in the target image. Phase-based MI provides a robust alternative similarity measure which, in addition to possessing the general robustness and noise immunity that MI provides, also employs local phase information in the registration process which makes it less susceptible to the aforementioned errors. In this paper, we propose using the complex wavelet transform for computing image phase information and incorporating that into a phase-based MI measure for image registration. Tests on a CT volume and 6 fluoroscopy images of the knee are presented. The femur and the tibia in the CT volume were individually registered to the fluoroscopy images using intensity-based MI, gradient-based MI and phase-based MI. Errors in the coordinates of fiducials present in the bone structures were used to assess the accuracy of the different registration schemes. Quantitative results demonstrate that the performance of intensity-based MI was the worst. Gradient-based MI performed slightly better, while phase-based MI results were the best consistently producing the lowest errors.
NASA Technical Reports Server (NTRS)
Chao, E. C. T.; Minkin, J. A.
1977-01-01
In the present paper, an attempt is made to delineate, on the basis of field and laboratory data, the phenomenon of formation of the Ries multiring basin - the best preserved very large terrestrial impact structure. The model proposed conforms to constraints imposed by geological, geophysical, and petrological studies and by the nature of the postulated impacting body. It is also based on the impact features of a stony meteorite measuring 3 km in diameter at an impact velocity of 15 km/sec. The schematic reconstruction shows that critical to the production of a shallow crater is shallow impact penetration (shallow depth of burst). This and the nonballistic ejection of excavated material appear to be genetically related, i.e., if extensive nonballistic transport is recognized, then the associated crater must be a shallow structure and vice versa. This also means the shallow configuration of a crater may not have anything to do with postcratering readjustment.
Double emittance exchanger as a bunch compressor for the MaRIE XFEL electron beam line at 1 GeV
NASA Astrophysics Data System (ADS)
Malyzhenkov, Alexander; Carlsten, Bruce E.; Yampolsky, Nikolai A.
2017-03-01
We demonstrate an alternative realization of a bunch compressor (specifically, the second bunch compressor for the MaRIE XFEL beamline, 1GeV electron energy) using a double emittance exchanger (EEX) and a telescope in the transverse phase space. We compare our results with a traditional bunch compressor realized via a chicane, taking into account the nonlinear dynamics, Coherent Synchrotron Radiation (CSR) and Space Charge (SC) effects. In particular, we use the Elegant code for tracking particles through the beamline, and analyze the evolution of the eigen-emittances to separate the influence of the CSR/SC effects from the nonlinear dynamics effects. We optimize the scheme parameters to reach a desirable compression factor and minimize the emittance growth. We observe dominant CSR effects in our scheme, resulting in critical emittance growth, and introduce an alternative version of an emittance exchanger with a reduced number of bending magnets to minimize the impact of CSR effects.
NASA Astrophysics Data System (ADS)
Van Toan, Nguyen; Inomata, Naoki; Trung, Nguyen Huu; Ono, Takahito
2018-05-01
This work describes the fabrication and evaluation of the Knudsen pump for on-chip vacuum pumping that works based on the principle of a thermal transpiration. Three AFM (atomic force microscope) cantilevers are integrated into small chambers with a size of 5 mm × 3 mm × 0.4 mm for the pump’s evaluation. Knudsen pump is fabricated using deep RIE (reactive ion etching), wet thermal oxidation and anodic bonding processes. The fabricated device is evaluated by monitoring the quality (Q) factor of the integrated cantilevers. The Q factor of the cantilever is increased from 300 -1150 in cases without and with a temperature difference approximately 25 °C between the top (the hot side at 40 °C) and bottom (the cold side at 15 °C) sides of the fabricated device, respectively. The evacuated chamber pressure of around 10 kPa is estimated from the Q factor of the integrated cantilevers.
Double Emittance Exchanger as a Bunch Compressor for the MaRIE XFEL electron beam line at 1GeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malyzhenkov, Alexander; Yampolsky, Nikolai; Carlsten, Bruce Eric
We demonstrate an alternative realization of a bunch compressor (specifically the second bunch compressor for the MaRIE XFEL beamline, 1GeV electron energy) using a double emittance exchanger (EEX) and a telescope in the transverse phase space.We compare our results with a traditional bunch compressor realized via chicane, taking into account the nonlinear dynamics, Coherent Synchrotron Radiation (CSR) and Space Charge (SC) effects. In particular, we use the Elegant code for tracking particles through the beam line and analyze the eigen-emittances evolution to separate the influence of the CSR/SC effects from the nonlinear dynamics effects. We optimize the scheme parameters tomore » reach a desirable compression factor and minimize the emittance growth. We observe dominant CSR-effects in our scheme resulting in critical emittance growth and introduce alternative version of an emittance exchanger with a reduced number of bending magnets to minimize the impact of CSR effects.« less
Counteracting structural errors in ensemble forecast of influenza outbreaks.
Pei, Sen; Shaman, Jeffrey
2017-10-13
For influenza forecasts generated using dynamical models, forecast inaccuracy is partly attributable to the nonlinear growth of error. As a consequence, quantification of the nonlinear error structure in current forecast models is needed so that this growth can be corrected and forecast skill improved. Here, we inspect the error growth of a compartmental influenza model and find that a robust error structure arises naturally from the nonlinear model dynamics. By counteracting these structural errors, diagnosed using error breeding, we develop a new forecast approach that combines dynamical error correction and statistical filtering techniques. In retrospective forecasts of historical influenza outbreaks for 95 US cities from 2003 to 2014, overall forecast accuracy for outbreak peak timing, peak intensity and attack rate, are substantially improved for predicted lead times up to 10 weeks. This error growth correction method can be generalized to improve the forecast accuracy of other infectious disease dynamical models.Inaccuracy of influenza forecasts based on dynamical models is partly due to nonlinear error growth. Here the authors address the error structure of a compartmental influenza model, and develop a new improved forecast approach combining dynamical error correction and statistical filtering techniques.
NASA Technical Reports Server (NTRS)
Mishchenko, M. I.; Lacis, A. A.; Travis, L. D.
1994-01-01
Although neglecting polarization and replacing the rigorous vector radiative transfer equation by its approximate scalar counterpart has no physical background, it is a widely used simplification when the incident light is unpolarized and only the intensity of the reflected light is to be computed. We employ accurate vector and scalar multiple-scattering calculations to perform a systematic study of the errors induced by the neglect of polarization in radiance calculations for a homogeneous, plane-parallel Rayleigh-scattering atmosphere (with and without depolarization) above a Lambertian surface. Specifically, we calculate percent errors in the reflected intensity for various directions of light incidence and reflection, optical thicknesses of the atmosphere, single-scattering albedos, depolarization factors, and surface albedos. The numerical data displayed can be used to decide whether or not the scalar approximation may be employed depending on the parameters of the problem. We show that the errors decrease with increasing depolarization factor and/or increasing surface albedo. For conservative or nearly conservative scattering and small surface albedos, the errors are maximum at optical thicknesses of about 1. The calculated errors may be too large for some practical applications, and, therefore, rigorous vector calculations should be employed whenever possible. However, if approximate scalar calculations are used, we recommend to avoid geometries involving phase angles equal or close to 0 deg and 90 deg, where the errors are especially significant. We propose a theoretical explanation of the large vector/scalar differences in the case of Rayleigh scattering. According to this explanation, the differences are caused by the particular structure of the Rayleigh scattering matrix and come from lower-order (except first-order) light scattering paths involving right scattering angles and right-angle rotations of the scattering plane.
Multiple Intravenous Infusions Phase 2b: Laboratory Study
Pinkney, Sonia; Fan, Mark; Chan, Katherine; Koczmara, Christine; Colvin, Christopher; Sasangohar, Farzan; Masino, Caterina; Easty, Anthony; Trbovich, Patricia
2014-01-01
Background Administering multiple intravenous (IV) infusions to a single patient via infusion pump occurs routinely in health care, but there has been little empirical research examining the risks associated with this practice or ways to mitigate those risks. Objectives To identify the risks associated with multiple IV infusions and assess the impact of interventions on nurses’ ability to safely administer them. Data Sources and Review Methods Forty nurses completed infusion-related tasks in a simulated adult intensive care unit, with and without interventions (i.e., repeated-measures design). Results Errors were observed in completing common tasks associated with the administration of multiple IV infusions, including the following (all values from baseline, which was current practice): setting up and programming multiple primary continuous IV infusions (e.g., 11.7% programming errors) identifying IV infusions (e.g., 7.7% line-tracing errors) managing dead volume (e.g., 96.0% flush rate errors following IV syringe dose administration) setting up a secondary intermittent IV infusion (e.g., 11.3% secondary clamp errors) administering an IV pump bolus (e.g., 11.5% programming errors) Of 10 interventions tested, 6 (1 practice, 3 technology, and 2 educational) significantly decreased or even eliminated errors compared to baseline. Limitations The simulation of an adult intensive care unit at 1 hospital limited the ability to generalize results. The study results were representative of nurses who received training in the interventions but had little experience using them. The longitudinal effects of the interventions were not studied. Conclusions Administering and managing multiple IV infusions is a complex and risk-prone activity. However, when a patient requires multiple IV infusions, targeted interventions can reduce identified risks. A combination of standardized practice, technology improvements, and targeted education is required. PMID:26316919
NASA Astrophysics Data System (ADS)
Chen, Xiao-jun; Dong, Li-zhi; Wang, Shuai; Yang, Ping; Xu, Bing
2017-11-01
In quadri-wave lateral shearing interferometry (QWLSI), when the intensity distribution of the incident light wave is non-uniform, part of the information of the intensity distribution will couple with the wavefront derivatives to cause wavefront reconstruction errors. In this paper, we propose two algorithms to reduce the influence of a non-uniform intensity distribution on wavefront reconstruction. Our simulation results demonstrate that the reconstructed amplitude distribution (RAD) algorithm can effectively reduce the influence of the intensity distribution on the wavefront reconstruction and that the collected amplitude distribution (CAD) algorithm can almost eliminate it.
Parent Education: Abstract Bibliography.
ERIC Educational Resources Information Center
Kremer, Barbara, Comp.
This bibliography has been compiled to alert educators to parent education documents found in the ERIC microfiche collection and in journal literature. Abstracts of selected documents have been taken from "Research in Education (RIE)", and journal article citations from the "Current Index to Journals in Education (CIJE)". Included are published…
School District Reorganization. Educational Management Review Series Number 12.
ERIC Educational Resources Information Center
Templeton, Ian
This review surveys recent documents previously announced in RIE that are concerned with school district reorganization. The review begins with a survey of literature on three interrelated variables that affect district consolidation and redistricting -- district size, educational quality, and educational costs. Succeeding sections present a…
Zumsteg, Zachary; DeMarco, John; Lee, Steve P; Steinberg, Michael L; Lin, Chun Shu; McBride, William; Lin, Kevin; Wang, Pin-Chieh; Kupelian, Patrick; Lee, Percy
2012-06-01
On-board cone-beam computed tomography (CBCT) is currently available for alignment of patients with head-and-neck cancer before radiotherapy. However, daily CBCT is time intensive and increases the overall radiation dose. We assessed the feasibility of using the average couch shifts from the first several CBCTs to estimate and correct for the presumed systematic setup error. 56 patients with head-and-neck cancer who received daily CBCT before intensity-modulated radiation therapy had recorded shift values in the medial-lateral, superior-inferior, and anterior-posterior dimensions. The average displacements in each direction were calculated for each patient based on the first five or 10 CBCT shifts and were presumed to represent the systematic setup error. The residual error after this correction was determined by subtracting the calculated shifts from the shifts obtained using daily CBCT. The magnitude of the average daily residual three-dimensional (3D) error was 4.8 ± 1.4 mm, 3.9 ± 1.3 mm, and 3.7 ± 1.1 mm for uncorrected, five CBCT corrected, and 10 CBCT corrected protocols, respectively. With no image guidance, 40.8% of fractions would have been >5 mm off target. Using the first five CBCT shifts to correct subsequent fractions, this percentage decreased to 19.0% of all fractions delivered and decreased the percentage of patients with average daily 3D errors >5 mm from 35.7% to 14.3% vs. no image guidance. Using an average of the first 10 CBCT shifts did not significantly improve this outcome. Using the first five CBCT shift measurements as an estimation of the systematic setup error improves daily setup accuracy for a subset of patients with head-and-neck cancer receiving intensity-modulated radiation therapy and primarily benefited those with large 3D correction vectors (>5 mm). Daily CBCT is still necessary until methods are developed that more accurately determine which patients may benefit from alternative imaging strategies. Copyright © 2012 Elsevier Inc. All rights reserved.
Regional climate modeling over the Maritime Continent: Assessment of RegCM3-BATS1e and RegCM3-IBIS
NASA Astrophysics Data System (ADS)
Gianotti, R. L.; Zhang, D.; Eltahir, E. A.
2010-12-01
Despite its importance to global rainfall and circulation processes, the Maritime Continent remains a region that is poorly simulated by climate models. Relatively few studies have been undertaken using a model with fine enough resolution to capture the small-scale spatial heterogeneity of this region and associated land-atmosphere interactions. These studies have shown that even regional climate models (RCMs) struggle to reproduce the climate of this region, particularly the diurnal cycle of rainfall. This study builds on previous work by undertaking a more thorough evaluation of RCM performance in simulating the timing and intensity of rainfall over the Maritime Continent, with identification of major sources of error. An assessment was conducted of the Regional Climate Model Version 3 (RegCM3) used in a coupled system with two land surface schemes: Biosphere Atmosphere Transfer System Version 1e (BATS1e) and Integrated Biosphere Simulator (IBIS). The model’s performance in simulating precipitation was evaluated against the 3-hourly TRMM 3B42 product, with some validation provided of this TRMM product against ground station meteorological data. It is found that the model suffers from three major errors in the rainfall histogram: underestimation of the frequency of dry periods, overestimation of the frequency of low intensity rainfall, and underestimation of the frequency of high intensity rainfall. Additionally, the model shows error in the timing of the diurnal rainfall peak, particularly over land surfaces. These four errors were largely insensitive to the choice of boundary conditions, convective parameterization scheme or land surface scheme. The presence of a wet or dry bias in the simulated volumes of rainfall was, however, dependent on the choice of convection scheme and boundary conditions. This study also showed that the coupled model system has significant error in overestimation of latent heat flux and evapotranspiration from the land surface, and specifically overestimation of interception loss with concurrent underestimation of transpiration, irrespective of the land surface scheme used. Discussion of the origin of these errors is provided, with some suggestions for improvement.
Sarazin, Philippe; Burstyn, Igor; Kincl, Laurel; Lavoué, Jérôme
2016-05-01
The Integrated Management Information System (IMIS) is the largest multi-industry source of exposure measurements available in North America. However, many have suspected that the criteria through which worksites are selected for inspection are related to exposure levels. We investigated associations between exposure levels and ancillary variables in IMIS in order to understand the predictors of high exposure within an enforcement context. We analyzed the association between nine variables (reason for inspection, establishment size, total amount of penalty, Occupational Safety and Health Administration (OSHA) plan, OSHA region, union status, inspection scope, year, and industry) and exposure levels in IMIS using multimodel inference for 77 agents. For each agent, we used two different types of models: (i) logistic models were used for the odds ratio (OR) of exposure being above the threshold limit value (TLV) and (ii) linear models were used for exposure concentrations restricted to detected results to estimate percent increase in exposure level, i.e. relative index of exposure (RIE). Meta-analytic methods were used to combine results for each variable across agents. A total of 511,047 exposure measurements were modeled for logistic models and 299,791 for linear models. Higher exposures were measured during follow-up inspections than planned inspections [meta-OR = 1.61, 95% confidence interval (CI): 1.44-1.81; meta-RIE = 1.06, 95% CI: 1.03-1.09]. Lower exposures were observed for measurements collected under state OSHA plans compared to measurements collected under federal OSHA (meta-OR = 0.82, 95% CI: 0.73-0.92; meta-RIE = 0.86, 95% CI: 0.81-0.91). A 'high' total historical amount of penalty relative to none was associated with higher exposures (meta-OR = 1.54, 95% CI: 1.40-1.71; meta-RIE = 1.18, 95% CI: 1.13-1.23). The relationships observed between exposure levels and ancillary variables across a vast majority of agents suggest that certain elements of OSHA's process of selecting worksites for inspection influence the exposure levels that OSHA inspectors encounter. Nonetheless, given the paucity of other sources of exposure data and the lack of a more demonstrably representative data source, our study considers the use of IMIS data for the estimation of exposures in the broader universe of worksites in the USA. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Method to mosaic gratings that relies on analysis of far-field intensity patterns in two wavelengths
NASA Astrophysics Data System (ADS)
Hu, Yao; Zeng, Lijiang; Li, Lifeng
2007-01-01
We propose an experimental method to coherently mosaic two planar diffraction gratings. The method uses a Twyman-Green interferometer to guarantee the planar parallelism of the two sub-aperture gratings, and obtains the in-plane rotational error and the two translational errors from analysis of the far-field diffraction intensity patterns in two alignment wavelengths. We adjust the relative attitude and position of the two sub-aperture gratings to produce Airy disk diffraction patterns in both wavelengths. In our experiment, the repeatability of in-plane rotation adjustment was 2.35 μrad and that of longitudinal adjustment was 0.11 μm. The accuracy of lateral adjustment was about 2.9% of the grating period.
Campion, Thomas R.; Waitman, Lemuel R.; May, Addison K.; Ozdas, Asli; Lorenzi, Nancy M.; Gadd, Cynthia S.
2009-01-01
Introduction: Evaluations of computerized clinical decision support systems (CDSS) typically focus on clinical performance changes and do not include social, organizational, and contextual characteristics explaining use and effectiveness. Studies of CDSS for intensive insulin therapy (IIT) are no exception, and the literature lacks an understanding of effective computer-based IIT implementation and operation. Results: This paper presents (1) a literature review of computer-based IIT evaluations through the lens of institutional theory, a discipline from sociology and organization studies, to demonstrate the inconsistent reporting of workflow and care process execution and (2) a single-site case study to illustrate how computer-based IIT requires substantial organizational change and creates additional complexity with unintended consequences including error. Discussion: Computer-based IIT requires organizational commitment and attention to site-specific technology, workflow, and care processes to achieve intensive insulin therapy goals. The complex interaction between clinicians, blood glucose testing devices, and CDSS may contribute to workflow inefficiency and error. Evaluations rarely focus on the perspective of nurses, the primary users of computer-based IIT whose knowledge can potentially lead to process and care improvements. Conclusion: This paper addresses a gap in the literature concerning the social, organizational, and contextual characteristics of CDSS in general and for intensive insulin therapy specifically. Additionally, this paper identifies areas for future research to define optimal computer-based IIT process execution: the frequency and effect of manual data entry error of blood glucose values, the frequency and effect of nurse overrides of CDSS insulin dosing recommendations, and comprehensive ethnographic study of CDSS for IIT. PMID:19815452
Chenault, Kristin; Moga, Michael-Alice; Shin, Minah; Petersen, Emily; Backer, Carl; De Oliveira, Gildasio S; Suresh, Santhanam
2016-05-01
Transfer of patient care among clinicians (handovers) is a common source of medical errors. While the immediate efficacy of these initiatives is well documented, sustainability of practice changes that results in better processes of care is largely understudied. The objective of the current investigation was to evaluate the sustainability of a protocolized handover process in pediatric patients from the operating room after cardiac surgery to the intensive care unit. This was a prospective study with direct observation assessment of handover performance conducted in the cardiac ICU (CICU) of a free-standing, tertiary care children's hospital in the United States. Patient transitions from the operating room to the CICU, including the verbal handoff, were directly observed by a single independent observer in all phases of the study. A checklist of key elements identified errors classified as: (1) technical, (2) information omissions, and (3) realized errors. Total number of errors was compared across the different times of the study (preintervention, postintervention, and the current sustainability phase). A total of 119 handovers were studied: 41 preintervention, 38 postintervention, and 40 in the current sustainability phase. The median [Interquartile range (IQR)] number of technical errors was significantly reduced in the sustainability phase compared to the preintervention and postintervention phase, 2 (1-3), 6 (5-7), and 2.5 (2-4), respectively P = 0.0001. Similarly, the median (IQR) number of verbal information omissions was also significantly reduced in the sustainability phase compared to the preintervention and postintervention phases, 1 (1-1), 4 (3-5) and 2 (1-3), respectively. We demonstrate sustainability of an improved handover process using a checklist in children being transferred to the intensive care unit after cardiac surgery. Standardized handover processes can be a sustainable strategy to improve patient safety after pediatric cardiac surgery. © 2016 John Wiley & Sons Ltd.
Cavanaugh, Debra A; Huse, Anita L
2004-01-01
The shortage of nurses has reached crisis proportions around the world. In response to a critical shortage of qualified neonatal intensive care nurses, one institution developed an educational program so comprehensive that they were able to increase their nursing staff by 20% and staff the neonatal intensive care unit with well-prepared and proficient nurses. This strategy has also resulted in high retention rates, a decrease in overtime, and a relatively low error rate by new nurses.
Intensity measurement of automotive headlamps using a photometric vision system
NASA Astrophysics Data System (ADS)
Patel, Balvant; Cruz, Jose; Perry, David L.; Himebaugh, Frederic G.
1996-01-01
Requirements for automotive head lamp luminous intensity tests are introduced. The rationale for developing a non-goniometric photometric test system is discussed. The design of the Ford photometric vision system (FPVS) is presented, including hardware, software, calibration, and system use. Directional intensity plots and regulatory test results obtained from the system are compared to corresponding results obtained from a Ford goniometric test system. Sources of error for the vision system and goniometer are discussed. Directions for new work are identified.
NASA Astrophysics Data System (ADS)
Kumkar, Yogesh V.; Sen, P. N.; Chaudhari, Hemankumar S.; Oh, Jai-Ho
2018-02-01
In this paper, an attempt has been made to conduct a numerical experiment with the high-resolution global model GME to predict the tropical storms in the North Indian Ocean during the year 2007. Numerical integrations using the icosahedral hexagonal grid point global model GME were performed to study the evolution of tropical cyclones, viz., Akash, Gonu, Yemyin and Sidr over North Indian Ocean during 2007. It has been seen that the GME model forecast underestimates cyclone's intensity, but the model can capture the evolution of cyclone's intensity especially its weakening during landfall, which is primarily due to the cutoff of the water vapor supply in the boundary layer as cyclones approach the coastal region. A series of numerical simulation of tropical cyclones have been performed with GME to examine model capability in prediction of intensity and track of the cyclones. The model performance is evaluated by calculating the root mean square errors as cyclone track errors.
In Vivo Validation of Numerical Prediction for Turbulence Intensity in an Aortic Coarctation
Arzani, Amirhossein; Dyverfeldt, Petter; Ebbers, Tino; Shadden, Shawn C.
2013-01-01
This paper compares numerical predictions of turbulence intensity with in vivo measurement. Magnetic resonance imaging (MRI) was carried out on a 60-year-old female with a restenosed aortic coarctation. Time-resolved three-directional phase-contrast (PC) MRI data was acquired to enable turbulence intensity estimation. A contrast-enhanced MR angiography (MRA) and a time-resolved 2D PCMRI measurement were also performed to acquire data needed to perform subsequent image-based computational fluid dynamics (CFD) modeling. A 3D model of the aortic coarctation and surrounding vasculature was constructed from the MRA data, and physiologic boundary conditions were modeled to match 2D PCMRI and pressure pulse measurements. Blood flow velocity data was subsequently obtained by numerical simulation. Turbulent kinetic energy (TKE) was computed from the resulting CFD data. Results indicate relative agreement (error ≈10%) between the in vivo measurements and the CFD predictions of TKE. The discrepancies in modeled vs. measured TKE values were within expectations due to modeling and measurement errors. PMID:22016327
Emotion identification in girls at high risk for depression.
Joormann, Jutta; Gilbert, Kirsten; Gotlib, Ian H
2010-05-01
Children of depressed mothers are themselves at elevated risk for developing a depressive disorder. We have little understanding, however, of the specific factors that contribute to this increased risk. This study investigated whether never-disordered daughters whose mothers have experienced recurrent episodes of depression during their daughters' lifetime differ from never-disordered daughters of never-disordered mothers in their processing of facial expressions of emotion. Following a negative mood induction, daughters completed an emotion identification task in which they watched faces slowly change from a neutral to a full-intensity happy, sad, or angry expression. We assessed both the intensity that was required to accurately identify the emotion being expressed and errors in emotion identification. Daughters of depressed mothers required greater intensity than did daughters of control mothers to accurately identify sad facial expressions; they also made significantly more errors identifying angry expressions. Cognitive biases may increase vulnerability for the onset of disorders and should be considered in early intervention and prevention efforts.
Residents' responses to medical error: coping, learning, and change.
Engel, Kirsten G; Rosenthal, Marilynn; Sutcliffe, Kathleen M
2006-01-01
To explore the significant emotional challenges facing resident physicians in the setting of medical mishaps, as well as their approaches to coping with these difficult experiences. Twenty-six resident physicians were randomly selected from a single teaching hospital and participated in in-depth qualitative interviews. Transcripts were analyzed iteratively and themes identified. Residents expressed intense emotional responses to error events. Poor patient outcomes and greater perceived personal responsibility were associated with more intense reactions and greater personal anguish. For the great majority of residents, their ability to cope with these events was dependent on a combination of reassurance and opportunities for learning. Interactions with medical colleagues and supervisory physicians were critical to this coping process. Medical mishaps have a profound impact on resident physicians by eliciting intense emotional responses. It is critical that resident training programs recognize the personal and professional significance of these experiences for young physicians. Moreover, resident education must support the development of constructive coping skills by facilitating candid discussion and learning subsequent to these events.
Muroi, Maki; Shen, Jay J; Angosta, Alona
2017-02-01
Registered nurses (RNs) play an important role in safe medication administration and patient safety. This study examined a total of 1276 medication error (ME) incident reports made by RNs in hospital inpatient settings in the southwestern region of the United States. The most common drug class associated with MEs was cardiovascular drugs (24.7%). Among this class, anticoagulants had the most errors (11.3%). The antimicrobials was the second most common drug class associated with errors (19.1%) and vancomycin was the most common antimicrobial that caused errors in this category (6.1%). MEs occurred more frequently in the medical-surgical and intensive care units than any other hospital units. Ten percent of MEs reached the patients with harm and 11% reached the patients with increased monitoring. Understanding the contributing factors related to MEs, addressing and eliminating risk of errors across hospital units, and providing education and resources for nurses may help reduce MEs. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Semenov, Z. V.; Labusov, V. A.
2017-11-01
Results of studying the errors of indirect monitoring by means of computer simulations are reported. The monitoring method is based on measuring spectra of reflection from additional monitoring substrates in a wide spectral range. Special software (Deposition Control Simulator) is developed, which allows one to estimate the influence of the monitoring system parameters (noise of the photodetector array, operating spectral range of the spectrometer and errors of its calibration in terms of wavelengths, drift of the radiation source intensity, and errors in the refractive index of deposited materials) on the random and systematic errors of deposited layer thickness measurements. The direct and inverse problems of multilayer coatings are solved using the OptiReOpt library. Curves of the random and systematic errors of measurements of the deposited layer thickness as functions of the layer thickness are presented for various values of the system parameters. Recommendations are given on using the indirect monitoring method for the purpose of reducing the layer thickness measurement error.
Effect of Pointing Error on the BER Performance of an Optical CDMA FSO Link with SIK Receiver
NASA Astrophysics Data System (ADS)
Nazrul Islam, A. K. M.; Majumder, S. P.
2017-12-01
An analytical approach is presented for an optical code division multiple access (OCDMA) system over free space optical (FSO) channel considering the effect of pointing error between the transmitter and the receiver. Analysis is carried out with an optical sequence inverse keying (SIK) correlator receiver with intensity modulation and direct detection (IM/DD) to find the bit error rate (BER) with pointing error. The results are evaluated numerically in terms of signal-to-noise plus multi-access interference (MAI) ratio, BER and power penalty due to pointing error. It is noticed that the OCDMA FSO system is highly affected by pointing error with significant power penalty at a BER of 10-6 and 10-9. For example, penalty at BER 10-9 is found to be 9 dB corresponding to normalized pointing error of 1.4 for 16 users with processing gain of 256 and is reduced to 6.9 dB when the processing gain is increased to 1,024.
Children's Rights and Child Advocacy: An ERIC Abstract Bibliography.
ERIC Educational Resources Information Center
ERIC Clearinghouse on Early Childhood Education, Champaign, IL.
This abstract bibliography cites recent ERIC documents and journal articles concerning the rights of children--in relation to the home, the school and other institutions--and advocacy for children. Entries include resumes from Resources in Education (RIE), January 1974 through December 1977, and citations from Current Index to Journals in…
Thermal Environments. Educational Facilities Review Series Number 17.
ERIC Educational Resources Information Center
Baas, Alan M.
This review surveys documents and journal articles previously announced in RIE and CIJE that deal with climate control, integrated thermal and luminous systems, total energy systems, and current trends in school air conditioning. The literature cited indicates that selection of thermal systems must take into account longterm operating costs in…
Bibliography of Soviet Laser Developments, Number 47, May - June 1980.
1981-04-09
23 p. (KL, 19/80, 17050) 99 IV. SOURCE ABBREVIATIONS (CIRC Codens) APP (A) (ATPLB) Acta physica polonica BAPS (BAPTA) Bulletin de l’Academie Polonaise...obraztsy, tovarnyye znaki PSS (PSSAB) Physica Status Solidi (A). Applied Research PTE (PRTEA) Pribory i tekhnika eksperimenta RiE (RAELA) Radiotekhnika i
Acoustical Environments. Educational Facilities Review Series Number 16.
ERIC Educational Resources Information Center
Baas, Alan M.
This review surveys documents and journal articles previously announced in RIE and CIJE that deal with the principles and techniques of sound transmission and control, particularly as they relate to school environments. School planners and administrators are advised that excessive acoustical insulation costs may be avoided by early decisions…
Ozonolysis and Oxyphotolysis of Municipal and Industrial Effluents.
1981-07-14
which it reacts. Reaction rates of such materials as bacteria, nitrites, hydrojen sulphide , unsaturated compounds, etc., are limited only by mass transfer...rate. The runs were conducted only A{ter allowing several minutes for the U.V. lamp to attain the ried power levels. 1 Two types of mercury lamp (low
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris William
Los Alamos National Laboratory (LANL) hosted the Stewardship Science Academic Programs Symposium, which is designed to foster relationships among young scientists, sponsors and the National Nuclear Security Administration national laboratories. The event highlights much of the work done by prominent scientists and allows attendees to view the multiple on site facilities at LANL.
ERIC Educational Resources Information Center
Bigelow, Terry Patrick; Ried, C. A.
2006-01-01
The first part of this article recounts the experiences of a language arts teacher, Terry Patrick Bigelow, and his former student, Cynthia (Noyes) Ried, who suffers from Fahr's Syndrome, a neurodegenerative congenital disease that forms calcium deposits deep inside the brain. It is irreversible, inoperable, and incurable. In the first part of the…
NASA Astrophysics Data System (ADS)
Alhalaili, Badriyah; Dryden, Daniel M.; Vidu, Ruxandra; Ghandiparsi, Soroush; Cansizoglu, Hilal; Gao, Yang; Saif Islam, M.
2018-03-01
Photo-electrochemical (PEC) etching can produce high-aspect ratio features, such as pillars and holes, with high anisotropy and selectivity, while avoiding the surface and sidewall damage caused by traditional deep reactive ion etching (DRIE) or inductively coupled plasma (ICP) RIE. Plasma-based techniques lead to the formation of dangling bonds, surface traps, carrier leakage paths, and recombination centers. In pursuit of effective PEC etching, we demonstrate an optical system using long wavelength (λ = 975 nm) infra-red (IR) illumination from a high-power laser (1-10 W) to control the PEC etching process in n-type silicon. The silicon wafer surface was patterned with notches through a lithography process and KOH etching. Then, PEC etching was introduced by illuminating the backside of the silicon wafer to enhance depth, resulting in high-aspect ratio structures. The effect of the PEC etching process was optimized by varying light intensities and electrolyte concentrations. This work was focused on determining and optimizing this PEC etching technique on silicon, with the goal of expanding the method to a variety of materials including GaN and SiC that are used in designing optoelectronic and electronic devices, sensors and energy harvesting devices.
Experimental measurement of structural power flow on an aircraft fuselage
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1991-01-01
An experimental technique is used to measure structural intensity through an aircraft fuselage with an excitation load applied near one of the wing attachment locations. The fuselage is a relatively large structure, requiring a large number of measurement locations to analyze the whole of the structure. For the measurement of structural intensity, multiple point measurements are necessary at every location of interest. A tradeoff is therefore required between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, structural intensity vectors are measured at locations distributed throughout the fuselage. To minimize the errors associated with using the four transducer technique, the measurement locations are selected to be away from bulkheads and stiffeners. Furthermore, to eliminate phase errors between the four transducer measurements, two sets of data are collected for each position, with the orientation of the platform with the four transducers rotated by 180 degrees and an average taken between the two sets of data. The results of these measurements together with a discussion of the suitability of the approach for measuring structural intensity on a real structure are presented.
Error measuring system of rotary Inductosyn
NASA Astrophysics Data System (ADS)
Liu, Chengjun; Zou, Jibin; Fu, Xinghe
2008-10-01
The inductosyn is a kind of high-precision angle-position sensor. It has important applications in servo table, precision machine tool and other products. The precision of inductosyn is calibrated by its error. It's an important problem about the error measurement in the process of production and application of the inductosyn. At present, it mainly depends on the method of artificial measurement to obtain the error of inductosyn. Therefore, the disadvantages can't be ignored such as the high labour intensity of the operator, the occurrent error which is easy occurred and the poor repeatability, and so on. In order to solve these problems, a new automatic measurement method is put forward in this paper which based on a high precision optical dividing head. Error signal can be obtained by processing the output signal of inductosyn and optical dividing head precisely. When inductosyn rotating continuously, its zero position error can be measured dynamically, and zero error curves can be output automatically. The measuring and calculating errors caused by man-made factor can be overcome by this method, and it makes measuring process more quickly, exactly and reliably. Experiment proves that the accuracy of error measuring system is 1.1 arc-second (peak - peak value).
Peppas, Kostas P; Lazarakis, Fotis; Alexandridis, Antonis; Dangakis, Kostas
2012-08-01
In this Letter we investigate the error performance of multiple-input multiple-output free-space optical communication systems employing intensity modulation/direct detection and operating over strong atmospheric turbulence channels. Atmospheric-induced strong turbulence fading is modeled using the negative exponential distribution. For the considered system, an approximate yet accurate analytical expression for the average bit error probability is derived and an efficient method for its numerical evaluation is proposed. Numerically evaluated and computer simulation results are further provided to demonstrate the validity of the proposed mathematical analysis.
An Error-Reduction Algorithm to Improve Lidar Turbulence Estimates for Wind Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Newman, Jennifer F.; Clifton, Andrew
2016-08-01
Currently, cup anemometers on meteorological (met) towers are used to measure wind speeds and turbulence intensity to make decisions about wind turbine class and site suitability. However, as modern turbine hub heights increase and wind energy expands to complex and remote sites, it becomes more difficult and costly to install met towers at potential sites. As a result, remote sensing devices (e.g., lidars) are now commonly used by wind farm managers and researchers to estimate the flow field at heights spanned by a turbine. While lidars can accurately estimate mean wind speeds and wind directions, there is still a largemore » amount of uncertainty surrounding the measurement of turbulence with lidars. This uncertainty in lidar turbulence measurements is one of the key roadblocks that must be overcome in order to replace met towers with lidars for wind energy applications. In this talk, a model for reducing errors in lidar turbulence estimates is presented. Techniques for reducing errors from instrument noise, volume averaging, and variance contamination are combined in the model to produce a corrected value of the turbulence intensity (TI), a commonly used parameter in wind energy. In the next step of the model, machine learning techniques are used to further decrease the error in lidar TI estimates.« less
Adaptive use of research aircraft data sets for hurricane forecasts
NASA Astrophysics Data System (ADS)
Biswas, M. K.; Krishnamurti, T. N.
2008-02-01
This study uses an adaptive observational strategy for hurricane forecasting. It shows the impacts of Lidar Atmospheric Sensing Experiment (LASE) and dropsonde data sets from Convection and Moisture Experiment (CAMEX) field campaigns on hurricane track and intensity forecasts. The following cases are used in this study: Bonnie, Danielle and Georges of 1998 and Erin, Gabrielle and Humberto of 2001. A single model run for each storm is carried out using the Florida State University Global Spectral Model (FSUGSM) with the European Center for Medium Range Weather Forecasts (ECMWF) analysis as initial conditions, in addition to 50 other model runs where the analysis is randomly perturbed for each storm. The centers of maximum variance of the DLM heights are located from the forecast error variance fields at the 84-hr forecast. Back correlations are then performed using the centers of these maximum variances and the fields at the 36-hr forecast. The regions having the highest correlations in the vicinity of the hurricanes are indicative of regions from where the error growth emanates and suggests the need for additional observations. Data sets are next assimilated in those areas that contain high correlations. Forecasts are computed using the new initial conditions for the storm cases, and track and intensity skills are then examined with respect to the control forecast. The adaptive strategy is capable of identifying sensitive areas where additional observations can help in reducing the hurricane track forecast errors. A reduction of position error by approximately 52% for day 3 of forecast (averaged over 7 storm cases) over the control runs is observed. The intensity forecast shows only a slight positive impact due to the model’s coarse resolution.
Using technology to prevent adverse drug events in the intensive care unit.
Hassan, Erkan; Badawi, Omar; Weber, Robert J; Cohen, Henry
2010-06-01
Critically ill patients are particularly susceptible to adverse drug events (ADEs) due to their rapidly changing and unstable physiology, complex therapeutic regimens, and large percentage of medications administered intravenously. There are a wide variety of technologies that can help prevent the points of failure commonly associated with ADEs (i.e., the five "Rights": right patient; right drug; right route; right dose; right frequency). These technologies are often categorized by their degree of complexity to design and engineer and the type of error they are designed to prevent. Focusing solely on the software and hardware design of technology may over- or underestimate the degree of difficulty to avoid ADEs at the bedside. Alternatively, we propose categorizing technological solutions by identifying the factors essential for success. The two major critical success factors are: 1) the degree of clinical assessment required by the clinician to appropriately evaluate and disposition the issue identified by a technology; and 2) the complexity associated with effective implementation. This classification provides a way of determining how ADE-preventing technologies in the intensive care unit can be successfully integrated into clinical practice. Although there are limited data on the effectiveness of many technologies in reducing ADEs, we will review the technologies currently available in the intensive care unit environment. We will also discuss critical success factors for implementation, common errors made during implementation, and the potential errors using these systems.
Hyper-Ramsey spectroscopy with probe-laser-intensity fluctuations
NASA Astrophysics Data System (ADS)
Beloy, K.
2018-03-01
We examine the influence of probe-laser-intensity fluctuations on hyper-Ramsey spectroscopy. We assume, as is appropriate for relevant cases of interest, that the probe-laser intensity I determines both the Rabi frequency (∝√{I } ) and the frequency shift to the atomic transition (∝I ) during probe-laser interactions with the atom. The spectroscopic signal depends on these two quantities that covary with fluctuations in the probe-laser intensity. Introducing a simple model for the fluctuations, we find that the signature robustness of the hyper-Ramsey method can be compromised. Taking the Yb+ electric octupole clock transition as an example, we quantify the clock error under different levels of probe-laser-intensity fluctuations.
Raman intensity as a probe of concentration near a crystal growing in solution
NASA Technical Reports Server (NTRS)
Wilkinson, R. Allen
1989-01-01
The feasibility of using Raman spectral scattering signals for measurements of concentration profiles near a crystal interface during growth or dissolution is discussed. With KH2PO4 (KDP) as a test material, optical multichannel analyzer (OMA) detection of a solute Raman vibrational band provided direct quantification of solute concentration with band intensity. The intersection of incident laser and Raman collection optics provided 3-D selective point measurements of the solution concentration field. Unlike many other techniques, the Raman band intensity is not sensitive to the typical temperature variations. Precision calibration of Raman intensity versus KDP concentration with less than 1 pct standard deviation error levels was demonstrated. A fiber optic, which sampled incident laser intensity and coupled it to the OMA, provided a fully synchronized monitor of fluctuations in laser power to correlate with observed Raman signals. With 1 W of laser power at the sample, good data statistics required eight repeated data collections at approximately 2.5 min collection. The accumulated time represents the concentration measurement time at one spatial location. Photomicroscopy documented a 30 micrometer diameter by 200 micrometer of laser Raman scattering region in the solution near the crystal surface. The laser beam was able to approach up to 25 micrometer from the crystal surface. However, a crystal surface reflected intensity contribution was weakly detectable. Nucleated microcrystals were seen in the crystal-growing solution. These microcrystals convect right up to the crystal surface and indicate no quiet diffusion region under normal gravity conditions. Translation of the solution cell with respect to the optics caused systematic intensity errors.
Archer, Steven M.
2007-01-01
Purpose Ordinary spherocylindrical refractive errors have been recognized as a cause of monocular diplopia for over a century, yet explanation of this phenomenon using geometrical optics has remained problematic. This study tests the hypothesis that the diffraction theory treatment of refractive errors will provide a more satisfactory explanation of monocular diplopia. Methods Diffraction theory calculations were carried out for modulation transfer functions, point spread functions, and line spread functions under conditions of defocus, astigmatism, and mixed spherocylindrical refractive errors. Defocused photographs of inked and projected black lines were made to demonstrate the predicted consequences of the theoretical calculations. Results For certain amounts of defocus, line spread functions resulting from spherical defocus are predicted to have a bimodal intensity distribution that could provide the basis for diplopia with line targets. Multimodal intensity distributions are predicted in point spread functions and provide a basis for diplopia or polyopia of point targets under conditions of astigmatism. The predicted doubling effect is evident in defocused photographs of black lines, but the effect is not as robust as the subjective experience of monocular diplopia. Conclusions Monocular diplopia due to ordinary refractive errors can be predicted from diffraction theory. Higher-order aberrations—such as spherical aberration—are not necessary but may, under some circumstances, enhance the features of monocular diplopia. The physical basis for monocular diplopia is relatively subtle, and enhancement by neural processing is probably needed to account for the robustness of the percept. PMID:18427616
Bilbao, Aivett; Gibbons, Bryson C.; Slysz, Gordon W.; ...
2017-11-06
We present that the mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can yield erroneous results if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flightmore » MS. Here, in this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases for highly saturated species and dynamic range increased by 1–2 orders of magnitude for peptides in a blood serum sample.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilbao, Aivett; Gibbons, Bryson C.; Slysz, Gordon W.
The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In thismore » method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilbao, Aivett; Gibbons, Bryson C.; Slysz, Gordon W.
We present that the mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can yield erroneous results if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flightmore » MS. Here, in this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases for highly saturated species and dynamic range increased by 1–2 orders of magnitude for peptides in a blood serum sample.« less
... the OSHA Directorate of Technical Support and Emergency Management at (202) 693-2300 for assistance accessing PDF materials. * These files are provided for downloading. ... Scope | Glossary | References | Site Map | Credits [an error occurred ...
NASA Astrophysics Data System (ADS)
Pradhan, P. K.; Liberato, Margarida L. R.; Ferreira, Juan A.; Dasamsetti, S.; Vijaya Bhaskara Rao, S.
2018-01-01
The role of the convective parameterization schemes (CPSs) in the ARW-WRF (WRF) mesoscale model is examined for extratropical cyclones (ETCs) over the North Atlantic Ocean. The simulation of very severe winter storms such as Xynthia (2010) and Gong (2013) are considered in this study. Most popular CPSs within WRF model, along with Yonsei University (YSU) planetary boundary layer (PBL) and WSM6 microphysical parameterization schemes are incorporated for the model experiments. For each storm, four numerical experiments were carried out using New Kain Fritsch (NKF), Betts-Miller-Janjic (BMJ), Grell 3D Ensemble (Gr3D) and no convection scheme (NCS) respectively. The prime objectives of these experiments were to recognize the best CPS that can forecast the intensity, track, and landfall over the Iberian Peninsula in advance of two days. The WRF model results such as central sea level pressure (CSLP), wind field, moisture flux convergence, geopotential height, jet stream, track and precipitation have shown sensitivity CPSs. The 48-hour lead simulations with BMJ schemes produce the best simulations both regarding ETCs intensity and track than Gr3D and NKF schemes. The average MAE and RMSE of intensities are least that (6.5 hPa in CSLP and 3.4 ms- 1 in the 10-m wind) found in BMJ scheme. The MAE and RMSE for and intensity and track error have revealed that NCS produces large errors than other CPSs experiments. However, for track simulation of these ETCs, at 72-, 48- and 24-hour means track errors were 440, 390 and 158 km respectively. In brevity, BMJ and Gr3D schemes can be used for short and medium range predictions of the ETCs over North Atlantic. For the evaluation of precipitation distributions using Gr3D scheme are good agreement with TRMM satellite than other CPSs.
Wave-optical assessment of alignment tolerances in nano-focusing with ellipsoidal mirror
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yumoto, Hirokatsu, E-mail: yumoto@spring8.or.jp; Koyama, Takahisa; Matsuyama, Satoshi
2016-01-28
High-precision ellipsoidal mirrors, which can efficiently focus X-rays to the nanometer dimension with a mirror, have not been realized because of the difficulties in the fabrication process. The purpose of our study was to develop nano-focusing ellipsoidal mirrors in the hard X-ray region. We developed a wave-optical focusing simulator for investigating alignment tolerances in nano-focusing with a designed ellipsoidal mirror, which produce a diffraction-limited focus size of 30 × 35 nm{sup 2} in full width at half maximum at an X-ray energy of 7 keV. The simulator can calculate focusing intensity distributions around the focal point under conditions of misalignment. Themore » wave-optical simulator enabled the calculation of interference intensity distributions, which cannot be predicted by the conventional ray-trace method. The alignment conditions with a focal length error of ≲ ±10 µm, incident angle error of ≲ ±0.5 µrad, and in-plane rotation angle error of ≲ ±0.25 µrad must be satisfied for nano-focusing.« less
Prasad, Devleena; Das, Pinaki; Saha, Niladri S; Chatterjee, Sanjoy; Achari, Rimpa; Mallick, Indranil
2014-01-01
This aim of this study was to determine if a less resource-intensive and established offline correction protocol - the No Action Level (NAL) protocol was as effective as daily online corrections of setup deviations in curative high-dose radiotherapy of prostate cancer. A total of 683 daily megavoltage CT (MVCT) or kilovoltage CT (kvCBCT) images of 30 patients with localized prostate cancer treated with intensity modulated radiotherapy were evaluated. Daily image-guidance was performed and setup errors in three translational axes recorded. The NAL protocol was simulated by using the mean shift calculated from the first five fractions and implemented on all subsequent treatments. Using the imaging data from the remaining fractions, the daily residual error (RE) was determined. The proportion of fractions where the RE was greater than 3,5 and 7 mm was calculated, and also the actual PTV margin that would be required if the offline protocol was followed. Using the NAL protocol reduced the systematic but not the random errors. Corrections made using the NAL protocol resulted in small and acceptable RE in the mediolateral (ML) and superoinferior (SI) directions with 46/533 (8.1%) and 48/533 (5%) residual shifts above 5 mm. However; residual errors greater than 5mm in the anteroposterior (AP) direction remained in 181/533 (34%) of fractions. The PTV margins calculated based on residual errors were 5mm, 5mm and 13 mm in the ML, SI and AP directions respectively. Offline correction using the NAL protocol resulted in unacceptably high residual errors in the AP direction, due to random uncertainties of rectal and bladder filling. Daily online imaging and corrections remain the standard image guidance policy for highly conformal radiotherapy of prostate cancer.
Optimization of Trade-offs in Error-free Image Transmission
NASA Astrophysics Data System (ADS)
Cox, Jerome R.; Moore, Stephen M.; Blaine, G. James; Zimmerman, John B.; Wallace, Gregory K.
1989-05-01
The availability of ubiquitous wide-area channels of both modest cost and higher transmission rate than voice-grade lines promises to allow the expansion of electronic radiology services to a larger community. The band-widths of the new services becoming available from the Integrated Services Digital Network (ISDN) are typically limited to 128 Kb/s, almost two orders of magnitude lower than popular LANs can support. Using Discrete Cosine Transform (DCT) techniques, a compressed approximation to an image may be rapidly transmitted. However, intensity or resampling transformations of the reconstructed image may reveal otherwise invisible artifacts of the approximate encoding. A progressive transmission scheme reported in ISO Working Paper N800 offers an attractive solution to this problem by rapidly reconstructing an apparently undistorted image from the DCT coefficients and then subse-quently transmitting the error image corresponding to the difference between the original and the reconstructed images. This approach achieves an error-free transmission without sacrificing the perception of rapid image delivery. Furthermore, subsequent intensity and resampling manipulations can be carried out with confidence. DCT coefficient precision affects the amount of error information that must be transmitted and, hence the delivery speed of error-free images. This study calculates the overall information coding rate for six radiographic images as a function of DCT coefficient precision. The results demonstrate that a minimum occurs for each of the six images at an average coefficient precision of between 0.5 and 1.0 bits per pixel (b/p). Apparently undistorted versions of these six images can be transmitted with a coding rate of between 0.25 and 0.75 b/p while error-free versions can be transmitted with an overall coding rate between 4.5 and 6.5 b/p.
NASA Astrophysics Data System (ADS)
Chung Liu, Wai; Wu, Bo; Wöhler, Christian
2018-02-01
Photoclinometric surface reconstruction techniques such as Shape-from-Shading (SfS) and Shape-and-Albedo-from-Shading (SAfS) retrieve topographic information of a surface on the basis of the reflectance information embedded in the image intensity of each pixel. SfS or SAfS techniques have been utilized to generate pixel-resolution digital elevation models (DEMs) of the Moon and other planetary bodies. Photometric stereo SAfS analyzes images under multiple illumination conditions to improve the robustness of reconstruction. In this case, the directional difference in illumination between the images is likely to affect the quality of the reconstruction result. In this study, we quantitatively investigate the effects of illumination differences on photometric stereo SAfS. Firstly, an algorithm for photometric stereo SAfS is developed, and then, an error model is derived to analyze the relationships between the azimuthal and zenith angles of illumination of the images and the reconstruction qualities. The developed algorithm and error model were verified with high-resolution images collected by the Narrow Angle Camera (NAC) of the Lunar Reconnaissance Orbiter Camera (LROC). Experimental analyses reveal that (1) the resulting error in photometric stereo SAfS depends on both the azimuthal and the zenith angles of illumination as well as the general intensity of the images and (2) the predictions from the proposed error model are consistent with the actual slope errors obtained by photometric stereo SAfS using the LROC NAC images. The proposed error model enriches the theory of photometric stereo SAfS and is of significance for optimized lunar surface reconstruction based on SAfS techniques.
Campion, Thomas R; Waitman, Lemuel R; May, Addison K; Ozdas, Asli; Lorenzi, Nancy M; Gadd, Cynthia S
2010-01-01
Evaluations of computerized clinical decision support systems (CDSS) typically focus on clinical performance changes and do not include social, organizational, and contextual characteristics explaining use and effectiveness. Studies of CDSS for intensive insulin therapy (IIT) are no exception, and the literature lacks an understanding of effective computer-based IIT implementation and operation. This paper presents (1) a literature review of computer-based IIT evaluations through the lens of institutional theory, a discipline from sociology and organization studies, to demonstrate the inconsistent reporting of workflow and care process execution and (2) a single-site case study to illustrate how computer-based IIT requires substantial organizational change and creates additional complexity with unintended consequences including error. Computer-based IIT requires organizational commitment and attention to site-specific technology, workflow, and care processes to achieve intensive insulin therapy goals. The complex interaction between clinicians, blood glucose testing devices, and CDSS may contribute to workflow inefficiency and error. Evaluations rarely focus on the perspective of nurses, the primary users of computer-based IIT whose knowledge can potentially lead to process and care improvements. This paper addresses a gap in the literature concerning the social, organizational, and contextual characteristics of CDSS in general and for intensive insulin therapy specifically. Additionally, this paper identifies areas for future research to define optimal computer-based IIT process execution: the frequency and effect of manual data entry error of blood glucose values, the frequency and effect of nurse overrides of CDSS insulin dosing recommendations, and comprehensive ethnographic study of CDSS for IIT. Copyright (c) 2009. Published by Elsevier Ireland Ltd.
Kasuga, Shoko; Kurata, Makiko; Liu, Meigen; Ushiba, Junichi
2015-05-01
Human's sophisticated motor learning system paradoxically interferes with motor performance when visual information is mirror-reversed (MR), because normal movement error correction further aggravates the error. This error-increasing mechanism makes performing even a simple reaching task difficult, but is overcome by alterations in the error correction rule during the trials. To isolate factors that trigger learners to change the error correction rule, we manipulated the gain of visual angular errors when participants made arm-reaching movements with mirror-reversed visual feedback, and compared the rule alteration timing between groups with normal or reduced gain. Trial-by-trial changes in the visual angular error was tracked to explain the timing of the change in the error correction rule. Under both gain conditions, visual angular errors increased under the MR transformation, and suddenly decreased after 3-5 trials with increase. The increase became degressive at different amplitude between the two groups, nearly proportional to the visual gain. The findings suggest that the alteration of the error-correction rule is not dependent on the amplitude of visual angular errors, and possibly determined by the number of trials over which the errors increased or statistical property of the environment. The current results encourage future intensive studies focusing on the exact rule-change mechanism. Copyright © 2014 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.
Measurement of bow tie profiles in CT scanners using a real-time dosimeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiting, Bruce R., E-mail: whitingbrucer@gmail.com; Evans, Joshua D.; Williamson, Jeffrey F.
2014-10-15
Purpose: Several areas of computed tomography (CT) research require knowledge about the intensity profile of the x-ray fan beam that is introduced by a bow tie filter. This information is considered proprietary by CT manufacturers, so noninvasive measurement methods are required. One method using real-time dosimeters has been proposed in the literature. A commercially available dosimeter was used to apply that method, and analysis techniques were developed to extract fan beam profiles from measurements. Methods: A real-time ion chamber was placed near the periphery of an empty CT gantry and the dose rate versus time waveform was recorded as themore » x-ray source rotated about the isocenter. In contrast to previously proposed analysis methods that assumed a pointlike detector, the finite-size ion chamber received varying amounts of coverage by the collimated x-ray beam during rotation, precluding a simple relationship between the source intensity as a function of fan beam angle and measured intensity. A two-parameter model for measurement intensity was developed that included both effective collimation width and source-to-detector distance, which then was iteratively solved to minimize the error between duplicate measurements at corresponding fan beam angles, allowing determination of the fan beam profile from measured dose-rate waveforms. Measurements were performed on five different scanner systems while varying parameters such as collimation, kVp, and bow tie filters. On one system, direct measurements of the bow tie profile were collected for comparison with the real-time dosimeter technique. Results: The data analysis method for a finite-size detector was found to produce a fan beam profile estimate with a relative error between duplicate measurement intensities of <5%. It was robust over a wide range of collimation widths (e.g., 1–40 mm), producing fan beam profiles that agreed with a relative error of 1%–5%. Comparison with a direct measurement technique on one system produced agreement with a relative error of 2%–6%. Fan beam profiles were found to differ for different filter types on a given system and between different vendors. Conclusions: A commercially available real-time dosimeter probe was found to be a convenient and accurate instrument for measuring fan beam profiles. An analysis method was developed that could handle a wide range of collimation widths by explicitly considering the finite width of the ion chamber. Relative errors in the profiles were found to be less than 5%. Measurements of five different clinical scanners demonstrate the variation in bow tie designs, indicating that generic bow tie models will not be adequate for CT system research.« less
The impact of underwater glider observations in the forecast of Hurricane Gonzalo (2014)
NASA Astrophysics Data System (ADS)
Goni, G. J.; Domingues, R. M.; Kim, H. S.; Domingues, R. M.; Halliwell, G. R., Jr.; Bringas, F.; Morell, J. M.; Pomales, L.; Baltes, R.
2017-12-01
The tropical Atlantic basin is one of seven global regions where tropical cyclones (TC) are commonly observed to originate and intensify from June to November. On average, approximately 12 TCs travel through the region every year, frequently affecting coastal, and highly populated areas. In an average year, 2 to 3 of them are categorized as intense hurricanes. Given the appropriate atmospheric conditions, TC intensification has been linked to ocean conditions, such as increased ocean heat content and enhanced salinity stratification near the surface. While errors in hurricane track forecasts have been reduced during the last years, errors in intensity forecasts remain mostly unchanged. Several studies have indicated that the use of in situ observations has the potential to improve the representation of the ocean to correctly initialize coupled hurricane intensity forecast models. However, a sustained in situ ocean observing system in the tropical North Atlantic Ocean and Caribbean Sea dedicated to measuring subsurface thermal and salinity fields in support of TC intensity studies and forecasts has yet to be implemented. Autonomous technologies offer new and cost-effective opportunities to accomplish this objective. We highlight here a partnership effort that utilize underwater gliders to better understand air-sea processes during high wind events, and are particularly geared towards improving hurricane intensity forecasts. Results are presented for Hurricane Gonzalo (2014), where glider observations obtained in the tropical Atlantic: Helped to provide an accurate description of the upper ocean conditions, that included the presence of a low salinity barrier layer; Allowed a detailed analysis of the upper ocean response to hurricane force winds of Gonzalo; Improved the initialization of the ocean in a coupled ocean-atmosphere numerical model; and together with observations from other ocean observing platforms, substantially reduced the error in intensity forecast using the HYCOM-HWRF model. Data collected by this project are transmitted in real-time to the Global Telecommunication System, distributed through the institutional web pages, by the IOOS Glider Data Assembly Center, and by NCEI, and assimilated in real-time numerical weather forecast models.
Imperfect pathogen detection from non-invasive skin swabs biases disease inference
DiRenzo, Graziella V.; Grant, Evan H. Campbell; Longo, Ana; Che-Castaldo, Christian; Zamudio, Kelly R.; Lips, Karen
2018-01-01
1. Conservation managers rely on accurate estimates of disease parameters, such as pathogen prevalence and infection intensity, to assess disease status of a host population. However, these disease metrics may be biased if low-level infection intensities are missed by sampling methods or laboratory diagnostic tests. These false negatives underestimate pathogen prevalence and overestimate mean infection intensity of infected individuals. 2. Our objectives were two-fold. First, we quantified false negative error rates of Batrachochytrium dendrobatidis on non-invasive skin swabs collected from an amphibian community in El Copé, Panama. We swabbed amphibians twice in sequence, and we used a recently developed hierarchical Bayesian estimator to assess disease status of the population. Second, we developed a novel hierarchical Bayesian model to simultaneously account for imperfect pathogen detection from field sampling and laboratory diagnostic testing. We evaluated the performance of the model using simulations and varying sampling design to quantify the magnitude of bias in estimates of pathogen prevalence and infection intensity. 3. We show that Bd detection probability from skin swabs was related to host infection intensity, where Bd infections < 10 zoospores have < 95% probability of being detected. If imperfect Bd detection was not considered, then Bd prevalence was underestimated by as much as 16%. In the Bd-amphibian system, this indicates a need to correct for imperfect pathogen detection caused by skin swabs in persisting host communities with low-level infections. More generally, our results have implications for study designs in other disease systems, particularly those with similar objectives, biology, and sampling decisions. 4. Uncertainty in pathogen detection is an inherent property of most sampling protocols and diagnostic tests, where the magnitude of bias depends on the study system, type of infection, and false negative error rates. Given that it may be difficult to know this information in advance, we advocate that the most cautious approach is to assume all errors are possible and to accommodate them by adjusting sampling designs. The modeling framework presented here improves the accuracy in estimating pathogen prevalence and infection intensity.
MW Spallation Neutron Sources for Fusion Materials Testing
Dr. Donald Rej
2018-04-18
Dr. Donald Rej of Los Alamos National Laboratory presents an overview of issues, needs, and performance gaps related to materials testing and how they are being addressed at their facility. Current projects such as the Los Alamos Neutron Science Center (LANSCE) and Matter-Radiation Interactions in Extremes (MaRIE) are also discussed.
Running Lean Startup in the Classroom: From Idea to Experiment in 1 Week
ERIC Educational Resources Information Center
Armstrong, Craig E.
2017-01-01
Entrepreneurship education is increasingly shifting from learning about entrepreneurship to developing entrepreneurial skills. One skill all entrepreneurship students need to develop is the ability to assess whether or not there is a market for their new product or service. Recent popular trade books like Eric Ries's "Lean Startup" and…
Especially for Teachers: Selected Documents on the Teaching of Science 1966-1981.
ERIC Educational Resources Information Center
Helgeson, Stanley, Comp.; And Others
Designed to supplement the day-to-day planning, teaching, and evaluation activities of science teachers at all educational levels, this compilation contains over 900 resumes of practitioner-oriented documents announced in "Resources in Education" (RIE) between 1966 and 1981. The resumes are presented under these headings: (1) elementary…
ERIC Educational Resources Information Center
American Association of School Administrators, Washington, DC.
ERIC abstracts on citizen involvement in the control of schools, announced in RIE through Novermber 1970, are presented. The key terms used in compiling this collection are "citizen participation,""decentralization,""parent participation,""parent school relationship,""school community relationship," and "school district autonomy." The following…
Must Public Education Restore Its Image as Great Equalizer?
ERIC Educational Resources Information Center
Carr, Nora
2006-01-01
Widely viewed today by many taxpayers, business leaders, and elected officials as inefficient, ineffective, bureaucratic, public education is losing its once-noble brand position as the cornerstone of American democracy. According to Laura Ries, a marketing guru, the first problem is the name, it is called public education. It is because the…
The Evaluation of Teachers. ERS Annotated Bibliography.
ERIC Educational Resources Information Center
Baral, Laurie R., Comp.
To provide a useful reference to published and unpublished documents relating to teacher evaluation, a search was made of the Education Index, Research in Education (RIE), and Current Index to Journals in Education (CIJE), which resulted in this 125-item bibliography. The source for each entry is indicated, along with pricing and ordering…
One Hundred Ninety-five Cases of High-voltage Electric Injury
2005-08-01
that level; and T4 to T5 paraplegia, secondary to fractures of T4 to T7. In 3 cases, frac- tures were not present: one case of a T11 to T12 sensory ...problems, including fractures, neurological inju- ries, ocular injuries, and complex reconstructive and re- habilitative needs, underscores the
Selective Nonoperative Management of Penetrating Torso Injury From Combat Fragmentation Wounds
2008-02-01
outlines the paradigm of care: “Penetrating inju- ries below the nipples , above the symphysis pubis, and between the posterior axillary lines must be...abdo- men and were hemodynamically stable and without abdom- inal pain or tenderness. CT scan of some of these casualties revealed fragments in the lumen
A Study on Mutil-Scale Background Error Covariances in 3D-Var Data Assimilation
NASA Astrophysics Data System (ADS)
Zhang, Xubin; Tan, Zhe-Min
2017-04-01
The construction of background error covariances is a key component of three-dimensional variational data assimilation. There are different scale background errors and interactions among them in the numerical weather Prediction. However, the influence of these errors and their interactions cannot be represented in the background error covariances statistics when estimated by the leading methods. So, it is necessary to construct background error covariances influenced by multi-scale interactions among errors. With the NMC method, this article firstly estimates the background error covariances at given model-resolution scales. And then the information of errors whose scales are larger and smaller than the given ones is introduced respectively, using different nesting techniques, to estimate the corresponding covariances. The comparisons of three background error covariances statistics influenced by information of errors at different scales reveal that, the background error variances enhance particularly at large scales and higher levels when introducing the information of larger-scale errors by the lateral boundary condition provided by a lower-resolution model. On the other hand, the variances reduce at medium scales at the higher levels, while those show slight improvement at lower levels in the nested domain, especially at medium and small scales, when introducing the information of smaller-scale errors by nesting a higher-resolution model. In addition, the introduction of information of larger- (smaller-) scale errors leads to larger (smaller) horizontal and vertical correlation scales of background errors. Considering the multivariate correlations, the Ekman coupling increases (decreases) with the information of larger- (smaller-) scale errors included, whereas the geostrophic coupling in free atmosphere weakens in both situations. The three covariances obtained in above work are used in a data assimilation and model forecast system respectively, and then the analysis-forecast cycles for a period of 1 month are conducted. Through the comparison of both analyses and forecasts from this system, it is found that the trends for variation in analysis increments with information of different scale errors introduced are consistent with those for variation in variances and correlations of background errors. In particular, introduction of smaller-scale errors leads to larger amplitude of analysis increments for winds at medium scales at the height of both high- and low- level jet. And analysis increments for both temperature and humidity are greater at the corresponding scales at middle and upper levels under this circumstance. These analysis increments improve the intensity of jet-convection system which includes jets at different levels and coupling between them associated with latent heat release, and these changes in analyses contribute to the better forecasts for winds and temperature in the corresponding areas. When smaller-scale errors are included, analysis increments for humidity enhance significantly at large scales at lower levels to moisten southern analyses. This humidification devotes to correcting dry bias there and eventually improves forecast skill of humidity. Moreover, inclusion of larger- (smaller-) scale errors is beneficial for forecast quality of heavy (light) precipitation at large (small) scales due to the amplification (diminution) of intensity and area in precipitation forecasts but tends to overestimate (underestimate) light (heavy) precipitation .
NASA Astrophysics Data System (ADS)
Islam, Muhymin; Mahmood, Arif; Bellah, Md.; Kim, Young-Tae; Iqbal, Samir
2014-03-01
Detection of circulating tumor cells (CTCs) in the early stages of cancer is requires very sensitive approach. Nanotextured polydimethylsiloxane (PDMS) substrates were fabricated by micro reactive ion etching (Micro-RIE) to have better control on surface morphology and to improve the affinity of PDMS surfaces to capture cancer cells using surface immobilized aptamers. The aptamers were specific to epidermal growth factor receptors (EGFR) present in cell membranes, and overexpressed in tumor cells. We also investigated the effect of nano-scale features on cell capturing by implementing various surfaces of different roughnesses. Three different recipes were used to prepare nanotextured PDMS by micro-RIE using oxygen (O2) and carbon tetrafluoride (CF4). The measured average roughness of three nanotextured PDMS surfaces were found to impact average densities of captured cells. In all cases, nanotextured PDMS facilitated cell capturing possibly due to increased effective surface area of roughened substrates at nanoscale. It was also observed that cell capture efficiency was higher for higher surface roughness. The nanotextured PDMS substrates are thus useful for cancer cytology devices.
Ravat, F.; Jault, P.; Gabard, J.
2015-01-01
Summary L’utilisation des bactériophages, prédateurs naturels des bactéries, est une technique pionnière efficace de lutte contre les infections bactériennes. Tombée dans l’oubli depuis un demi-siècle du coté occidental de l’ex-rideau de fer, elle fait toujours partie de l’arsenal thérapeutique des pays de l’ex-Europe de l’Est, au point de constituer une arme de choix dans la politique de santé publique de ces pays. l’émergence de bactéries multirésistantes et le risque de revenir à l’ère pré-antibiotique ont fait ressortir la phagothérapie de l’oubli injuste auquel elle avait été confinée. la biologie et la place du bactériophage dans la nature sont décrites ici. les tenants et les aboutissants de la phagothérapie et les conditions de son retour sur le devant de la scène sont explicitées. PMID:26668557
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraus, R. G.; Mcnabb, D.; Kumar, M.
The National Nuclear Security Agency has recently recognized that a long-term need exists to establish a stronger scientific basis for the assessment and qualification of materials and manufacturing processes for the nuclear stockpile and other national security applications. These materials may have undergone substantial changes with age, or may represent new materials that are being introduced because of difficulties associated with reusing or recreating materials used in original stockpile components. Also, with advancements in manufacturing methods, the NNSA anticipates opportunities for an enhanced range of control over fabricated components, an enhanced pace of materials development, and enhanced functionality. The developmentmore » of qualification standards for these new materials will require the ability to understand and control material characteristics that affect both mechanical and dynamic performance. A unique aspect for NNSA is that the performance requirements for materials are often set by system hydrodynamics, and these materials must perform in extreme environments and loading conditions. Thus, the scientific motivation is to understand “Matter-Radiation Interactions in Extremes (MaRIE).”« less
NASA Technical Reports Server (NTRS)
Nishimura, T.
1975-01-01
This paper proposes a worst-error analysis for dealing with problems of estimation of spacecraft trajectories in deep space missions. Navigation filters in use assume either constant or stochastic (Markov) models for their estimated parameters. When the actual behavior of these parameters does not follow the pattern of the assumed model, the filters sometimes result in very poor performance. To prepare for such pathological cases, the worst errors of both batch and sequential filters are investigated based on the incremental sensitivity studies of these filters. By finding critical switching instances of non-gravitational accelerations, intensive tracking can be carried out around those instances. Also the worst errors in the target plane provide a measure in assignment of the propellant budget for trajectory corrections. Thus the worst-error study presents useful information as well as practical criteria in establishing the maneuver and tracking strategy of spacecraft's missions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S; Robinson, A; Kiess, A
2015-06-15
Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCTmore » intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.« less
Exploiting data representation for fault tolerance
Hoemmen, Mark Frederick; Elliott, J.; Sandia National Lab.; ...
2015-01-06
Incorrect computer hardware behavior may corrupt intermediate computations in numerical algorithms, possibly resulting in incorrect answers. Prior work models misbehaving hardware by randomly flipping bits in memory. We start by accepting this premise, and present an analytic model for the error introduced by a bit flip in an IEEE 754 floating-point number. We then relate this finding to the linear algebra concepts of normalization and matrix equilibration. In particular, we present a case study illustrating that normalizing both vector inputs of a dot product minimizes the probability of a single bit flip causing a large error in the dot product'smore » result. Moreover, the absolute error is either less than one or very large, which allows detection of large errors. Then, we apply this to the GMRES iterative solver. We count all possible errors that can be introduced through faults in arithmetic in the computationally intensive orthogonalization phase of GMRES, and show that when the matrix is equilibrated, the absolute error is bounded above by one.« less
Medicine and aviation: a review of the comparison.
Randell, R
2003-01-01
This paper aims to understand the nature of medical error in highly technological environments and argues that a comparison with aviation can blur its real understanding. This study is a comparative study between the notion of error in health care and aviation based on the author's own ethnographic study in intensive care units and findings from the research literature on errors in aviation. Failures in the use of medical technology are common. In attempts to understand the area of medical error, much attention has focused on how we can learn from aviation. This paper argues that such a comparison is not always useful, on the basis that (i) the type of work and technology is very different in the two domains; (ii) different issues are involved in training and procurement; and (iii) attitudes to error vary between the domains. Therefore, it is necessary to look closely at the subject of medical error and resolve those questions left unanswered by the lessons of aviation.
Passarge, Michelle; Fix, Michael K; Manser, Peter; Stampanoni, Marco F M; Siebers, Jeffrey V
2017-04-01
To develop a robust and efficient process that detects relevant dose errors (dose errors of ≥5%) in external beam radiation therapy and directly indicates the origin of the error. The process is illustrated in the context of electronic portal imaging device (EPID)-based angle-resolved volumetric-modulated arc therapy (VMAT) quality assurance (QA), particularly as would be implemented in a real-time monitoring program. A Swiss cheese error detection (SCED) method was created as a paradigm for a cine EPID-based during-treatment QA. For VMAT, the method compares a treatment plan-based reference set of EPID images with images acquired over each 2° gantry angle interval. The process utilizes a sequence of independent consecutively executed error detection tests: an aperture check that verifies in-field radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment check to examine if rotation, scaling, and translation are within tolerances; pixel intensity check containing the standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each check were determined. To test the SCED method, 12 different types of errors were selected to modify the original plan. A series of angle-resolved predicted EPID images were artificially generated for each test case, resulting in a sequence of precalculated frames for each modified treatment plan. The SCED method was applied multiple times for each test case to assess the ability to detect introduced plan variations. To compare the performance of the SCED process with that of a standard gamma analysis, both error detection methods were applied to the generated test cases with realistic noise variations. Averaged over ten test runs, 95.1% of all plan variations that resulted in relevant patient dose errors were detected within 2° and 100% within 14° (<4% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 89.1% were detected by the SCED method within 2°. Based on the type of check that detected the error, determination of error sources was achieved. With noise ranging from no random noise to four times the established noise value, the averaged relevant dose error detection rate of the SCED method was between 94.0% and 95.8% and that of gamma between 82.8% and 89.8%. An EPID-frame-based error detection process for VMAT deliveries was successfully designed and tested via simulations. The SCED method was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of relevant dose errors. Compared to a typical (3%, 3 mm) gamma analysis, the SCED method produced a higher detection rate for all introduced dose errors, identified errors in an earlier stage, displayed a higher robustness to noise variations, and indicated the error source. © 2017 American Association of Physicists in Medicine.
The Origin of Systematic Errors in the GCM Simulation of ITCZ Precipitation
NASA Technical Reports Server (NTRS)
Chao, Winston C.; Suarez, M. J.; Bacmeister, J. T.; Chen, B.; Takacs, L. L.
2006-01-01
Previous GCM studies have found that the systematic errors in the GCM simulation of the seasonal mean ITCZ intensity and location could be substantially corrected by adding suitable amount of rain re-evaporation or cumulus momentum transport. However, the reason(s) for these systematic errors and solutions has remained a puzzle. In this work the knowledge gained from previous studies of the ITCZ in an aqua-planet model with zonally uniform SST is applied to solve this puzzle. The solution is supported by further aqua-planet and full model experiments using the latest version of the Goddard Earth Observing System GCM.
Estimating pixel variances in the scenes of staring sensors
Simonson, Katherine M [Cedar Crest, NM; Ma, Tian J [Albuquerque, NM
2012-01-24
A technique for detecting changes in a scene perceived by a staring sensor is disclosed. The technique includes acquiring a reference image frame and a current image frame of a scene with the staring sensor. A raw difference frame is generated based upon differences between the reference image frame and the current image frame. Pixel error estimates are generated for each pixel in the raw difference frame based at least in part upon spatial error estimates related to spatial intensity gradients in the scene. The pixel error estimates are used to mitigate effects of camera jitter in the scene between the current image frame and the reference image frame.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nolan, Michael W., E-mail: mwnolan@ncsu.edu; Department of Environmental and Radiologic Health Sciences, Colorado State University, Fort Collins, Colorado; Marolf, Angela J.
Purpose/Objectives: Erectile dysfunction is common after radiation therapy for prostate cancer; yet, the etiopathology of radiation-induced erectile dysfunction (RI-ED) remains poorly understood. A novel animal model was developed to study RI-ED, wherein stereotactic body radiation therapy (SBRT) was used to irradiate the prostate, neurovascular bundles (NVB), and penile bulb (PB) of dogs. The purpose was to describe vascular and neurogenic injuries after the irradiation of only the NVB or the PB, and after irradiation of all 3 sites (prostate, NVB, and PB) with varying doses of radiation. Methods and Materials: Dogs were treated with 50, 40, or 30 Gy to themore » prostate, NVB, and PB, or 50 Gy to either the NVB or the PB, by 5-fraction SBRT. Electrophysiologic studies of the pudendal nerve and bulbospongiosus muscles and ultrasound studies of pelvic perfusion were performed before and after SBRT. The results of these bioassays were correlated with histopathologic changes. Results: SBRT caused slowing of the systolic rise time, which corresponded to decreased arterial patency. Alterations in the response of the internal pudendal artery to vasoactive drugs were observed, wherein SBRT caused a paradoxical response to papaverine, slowing the systolic rise time after 40 and 50 Gy; these changes appeared to have some dose dependency. The neurofilament content of penile nerves was also decreased at high doses and was more profound when the PB was irradiated than when the NVB was irradiated. These findings are coincident with slowing of motor nerve conduction velocities in the pudendal nerve after SBRT. Conclusions: This is the first report in which prostatic irradiation was shown to cause morphologic arterial damage that was coincident with altered internal pudendal arterial tone, and in which decreased motor function in the pudendal nerve was attributed to axonal degeneration and loss. Further investigation of the role played by damage to these structures in RI-ED is warranted.« less
La replantation digitale, résultats et complications: étude d’une série de 18 cas
Idrissi, Mohammed El; Elibrahimi, Abdelhalim; Shimi, Mohammed; Elmrini, Abdelmajid
2016-01-01
Les amputations digitales sont des lésions fréquentes, la majorité étant provoquée par des accidents de travail. Les techniques microchirurgicales représentent une alternative pour réparer ces amputations. L'objectif de ce travail est de rapporter notre expérience dans la replantation digitale à travers l'étude de 18 cas. Nous avons mené une étude rétrospective, étalée entre Juin 2013 et Janvier 2015, incluant 14 patients présentant une amputation totale ou subtotale des doigts. Nous avons inclus dans notre série toutes les replantations unidigitales et multidigitales réalisées en aval de l'insertion distale du tendon fléchisseur superficiel ainsi que les replantations digitales réalisées en amont de l'insertion distale du tendon fléchisseur superficiel. Nous avons opéré ces patients selon le procédé classique de réimplantation digitale. Cinq replantations ont été secondairement régularisées. Parmi les 18 replantations, huit replantions digitales ont favorablement évolué puisque la replantation a permis de restituer un secteur complet de mobilité passive et active du doigt opéré sans chirurgie de reprise et sans complication secondaire précoce et tardive. Dans notre étude nous avons noté des résultats satisfaisants, malgré les conditions difficiles notamment le conditionnement initial du doigt amputé, et le délai de prise en charge retardé. Le développement et la maîtrise de la microchirurgie a permis de changer le pronostic de ces amputations à retentissement fonctionnel et psychologique difficile, les résultats de notre série sont encourageants pour a mise en place d'un service SOS main au Maroc. PMID:27795781
Astronomia Motivadora no Ensino Fundamental
NASA Astrophysics Data System (ADS)
Melo, J.; Voelzke, M. R.
2008-09-01
O objetivo principal deste trabalho é procurar desenvolver o interesse dos alunos pelas ciências através da Astronomia. Uma pesquisa com perguntas sobre Astronomia foi realizada junto a 161 alunos do Ensino Fundamental, com o intuito de descobrir conhecimentos prévios dos alunos sobre o assunto. Constatou-se, por exemplo, que 29,3% da 6ª série responderam corretamente o que é eclipse, 30,0% da 8ª série acertaram o que a Astronomia estuda, enquanto 42,3% dos alunos da 5ª série souberam definir o Sol. Pretende-se ampliar as turmas participantes e trabalhar, principalmente de forma prática com: dimensões e escalas no Sistema Solar, construção de luneta, questões como dia e noite, estações do ano e eclipses. Busca-se abordar, também, outros conteúdos de Física tais como a óptica na construção da luneta, e a mecânica no trabalho com escalas e medidas, e ao utilizar uma luminária para representar o Sol na questão do eclipse, e de outras disciplinas como a Matemática na transformação de unidades, regras de três; Artes na modelagem ou desenho dos planetas; a própria História com relação à busca pela origem do universo, e a Informática que possibilita a busca mais rápida por informações, além de permitir simulações e visualizações de imagens importantes. Acredita-se que a Astronomia é importante no processo ensino aprendizagem, pois permite a discussão de temas curiosos como, por exemplo, a origem do universo, viagens espaciais a existência ou não de vida em outros planetas, além de temas atuais como as novas tecnologias.
Optical performance of random anti-reflection structured surfaces (rARSS) on spherical lenses
NASA Astrophysics Data System (ADS)
Taylor, Courtney D.
Random anti-reflection structured surfaces (rARSS) have been reported to improve transmittance of optical-grade fused silica planar substrates to values greater than 99%. These textures are fabricated directly on the substrates using reactive-ion/inductively-coupled plasma etching (RIE/ICP) techniques, and often result in transmitted spectra with no measurable interference effects (fringes) for a wide range of wavelengths. The RIE/ICP processes used in the fabrication process to etch the rARSS is anisotropic and thus well suited for planar components. The improvement in spectral transmission has been found to be independent of optical incidence angles for values from 0° to +/-30°. Qualifying and quantifying the rARSS performance on curved substrates, such as convex lenses, is required to optimize the fabrication of the desired AR effect on optical-power elements. In this work, rARSS was fabricated on fused silica plano-convex (PCX) and plano-concave (PCV) lenses using a planar-substrate optimized RIE process to maximize optical transmission in the range from 500 to 1100 nm. An additional set of lenses were etched in a non-optimized ICP process to provide additional comparisons. Results are presented from optical transmission and beam propagation tests (optimized lenses only) of rARSS lenses for both TE and TM incident polarizations at a wavelength of 633 nm and over a 70° full field of view in both singlet and doublet configurations. These results suggest optimization of the fabrication process is not required, mainly due to the wide angle-of-incidence AR tolerance performance of the rARSS lenses. Non-optimized recipe lenses showed low transmission enhancement, and confirmed the need to optimized etch recipes prior to process transfer of PCX/PCV lenses. Beam propagation tests indicated no major beam degradation through the optimized lens elements. Scanning electron microscopy (SEM) images confirmed different structure between optimized and non-optimized samples. SEM images also indicated isotropically-oriented surface structures on both types of lenses.
StreamStats in North Carolina: a water-resources Web application
Weaver, J. Curtis; Terziotti, Silvia; Kolb, Katharine R.; Wagner, Chad R.
2012-01-01
A statewide StreamStats application for North Carolina was developed in cooperation with the North Carolina Department of Transportation following completion of a pilot application for the upper French Broad River basin in western North Carolina (Wagner and others, 2009). StreamStats for North Carolina, available at http://water.usgs.gov/osw/streamstats/north_carolina.html, is a Web-based Geographic Information System (GIS) application developed by the U.S. Geological Survey (USGS) in consultation with Environmental Systems Research Institute, Inc. (Esri) to provide access to an assortment of analytical tools that are useful for water-resources planning and management (Ries and others, 2008). The StreamStats application provides an accurate and consistent process that allows users to easily obtain streamflow statistics, basin characteristics, and descriptive information for USGS data-collection sites and user-selected ungaged sites. In the North Carolina application, users can compute 47 basin characteristics and peak-flow frequency statistics (Weaver and others, 2009; Robbins and Pope, 1996) for a delineated drainage basin. Selected streamflow statistics and basin characteristics for data-collection sites have been compiled from published reports and also are immediately accessible by querying individual sites from the web interface. Examples of basin characteristics that can be computed in StreamStats include drainage area, stream slope, mean annual precipitation, and percentage of forested area (Ries and others, 2008). Examples of streamflow statistics that were previously available only through published documents include peak-flow frequency, flow-duration, and precipitation data. These data are valuable for making decisions related to bridge design, floodplain delineation, water-supply permitting, and sustainable stream quality and ecology. The StreamStats application also allows users to identify stream reaches upstream and downstream from user-selected sites and obtain information for locations along streams where activities occur that may affect streamflow conditions. This functionality can be accessed through a map-based interface with the user’s Web browser, or individual functions can be requested remotely through Web services (Ries and others, 2008).
Valdez, Michelle M; Liwanag, Maureen; Mount, Charles; Rodriguez, Rechell; Avalos-Reyes, Elisea; Smith, Andrew; Collette, David; Starsiak, Michael; Green, Richard
2018-03-14
Inefficiencies in the command approval process for publications and/or presentations negatively impact DoD Graduate Medical Education (GME) residency programs' ability to meet ACGME scholarly activity requirements. A preliminary review of the authored works approval process at Naval Medical Center San Diego (NMCSD) disclosed significant inefficiency, variation in process, and a low level of customer satisfaction. In order to facilitate and encourage scholarly activity at NMCSD, and meet ACGME requirements, the Executive Steering Council (ESC) chartered an interprofessional team to lead a Lean Six Sigma (LSS) Rapid Improvement Event (RIE) project. Two major outcome metrics were identified: (1) the number of authored works submissions containing all required signatures and (2) customer satisfaction with the authored works process. Primary metric baseline data were gathered utilizing a Clinical Investigations database tracking publications and presentations. Secondary metric baseline data were collected via a customer satisfaction survey to GME faculty and residents. The project team analyzed pre-survey data and utilized LSS tools and methodology including a "gemba" (environment) walk, cause and effect diagram, critical to quality tree, voice of the customer, "muda" (waste) chart, and a pre- and post-event value stream map. The team selected an electronic submission system as the intervention most likely to positively impact the RIE project outcome measures. The number of authored works compliant with all required signatures improved from 52% to 100%. Customer satisfaction rated as "completely or mostly satisfied" improved from 24% to 97%. For both outcomes, signature compliance and customer satisfaction, statistical significance was achieved with a p < 0.0001. This RIE project utilized LSS methodology and tools to improve signature compliance and increase customer satisfaction with the authored works approval process, leading to 100% signature compliance, a comprehensive longitudinal repository of all authored work requests, and a 97% "completely or mostly satisfied" customer rating of the process.
What do IPAQ questions mean to older adults? Lessons from cognitive interviews
2010-01-01
Background Most questionnaires used for physical activity (PA) surveillance have been developed for adults aged ≤65 years. Given the health benefits of PA for older adults and the aging of the population, it is important to include adults aged 65+ years in PA surveillance. However, few studies have examined how well older adults understand PA surveillance questionnaires. This study aimed to document older adults' understanding of questions from the International PA Questionnaire (IPAQ), which is used worldwide for PA surveillance. Methods Participants were 41 community-dwelling adults aged 65-89 years. They each completed IPAQ in a face-to-face semi-structured interview, using the "think-aloud" method, in which they expressed their thoughts out loud as they answered IPAQ questions. Interviews were transcribed and coded according to a three-stage model: understanding the intent of the question; performing the primary task (conducting the mental operations required to formulate a response); and response formatting (mapping the response into pre-specified response options). Results Most difficulties occurred during the understanding and performing the primary task stages. Errors included recalling PA in an "average" week, not in the previous 7 days; including PA lasting <10 minutes/session; reporting the same PA twice or thrice; and including the total time of an activity for which only a part of that time was at the intensity specified in the question. Participants were unclear what activities fitted within a question's scope and used a variety of strategies for determining the frequency and duration of their activities. Participants experienced more difficulties with the moderate-intensity PA and walking questions than with the vigorous-intensity PA questions. The sitting time question, particularly difficult for many participants, required the use of an answer strategy different from that used to answer questions about PA. Conclusions These findings indicate a need for caution in administering IPAQ to adults aged ≥65 years. Most errors resulted in over-reporting, although errors resulting in under-reporting were also noted. Given the nature of the errors made by participants, it is possible that similar errors occur when IPAQ is used in younger populations and that the errors identified could be minimized with small modifications to IPAQ. PMID:20459758
Validity of an Integrative Method for Processing Physical Activity Data.
Ellingson, Laura D; Schwabacher, Isaac J; Kim, Youngwon; Welk, Gregory J; Cook, Dane B
2016-08-01
Accurate assessments of both physical activity and sedentary behaviors are crucial to understand the health consequences of movement patterns and to track changes over time and in response to interventions. The study evaluates the validity of an integrative, machine learning method for processing activity monitor data in relation to a portable metabolic analyzer (Oxycon mobile [OM]) and direct observation (DO). Forty-nine adults (age 18-40 yr) each completed 5-min bouts of 15 activities ranging from sedentary to vigorous intensity in a laboratory setting while wearing ActiGraph (AG) on the hip, activPAL on the thigh, and OM. Estimates of energy expenditure (EE) and categorization of activity intensity were obtained from the AG processed with Lyden's sojourn (SOJ) method and from our new sojourns including posture (SIP) method, which integrates output from the AG and activPAL. Classification accuracy and estimates of EE were then compared with criterion measures (OM and DO) using confusion matrices and comparisons of the mean absolute error of log-transformed data (MAE ln Q). The SIP method had a higher overall classification agreement (79%, 95% CI = 75%-82%) than the SOJ (56%, 95% CI = 52%-59%) based on DO. Compared with OM, estimates of EE from SIP had lower mean absolute error of log-transformed data than SOJ for light-intensity (0.21 vs 0.27), moderate-intensity (0.33 vs 0.42), and vigorous-intensity (0.16 vs 0.35) activities. The SIP method was superior to SOJ for distinguishing between sedentary and light activities as well as estimating EE at higher intensities. Thus, SIP is recommended for research in which accuracy of measurement across the full range of activity intensities is of interest.
The minimal local-asperity hypothesis of early retinal lateral inhibition.
Balboa, R M; Grzywacz, N M
2000-07-01
Recently we found that the theories related to information theory existent in the literature cannot explain the behavior of the extent of the lateral inhibition mediated by retinal horizontal cells as a function of background light intensity. These theories can explain the fall of the extent from intermediate to high intensities, but not its rise from dim to intermediate intensities. We propose an alternate hypothesis that accounts for the extent's bell-shape behavior. This hypothesis proposes that the lateral-inhibition adaptation in the early retina is part of a system to extract several image attributes, such as occlusion borders and contrast. To do so, this system would use prior probabilistic knowledge about the biological processing and relevant statistics in natural images. A key novel statistic used here is the probability of the presence of an occlusion border as a function of local contrast. Using this probabilistic knowledge, the retina would optimize the spatial profile of lateral inhibition to minimize attribute-extraction error. The two significant errors that this minimization process must reduce are due to the quantal noise in photoreceptors and the straddling of occlusion borders by lateral inhibition.
Improvable method for Halon 1301 concentration measurement based on infrared absorption
NASA Astrophysics Data System (ADS)
Hu, Yang; Lu, Song; Guan, Yu
2015-09-01
Halon 1301 has attached much interest because of its pervasive use as an effective fire suppressant agent in aircraft related fires, and the study of fire suppressant agent concentration measurement is especially of interest. In this work, a Halon 1301 concentration measurement method based on the Beer-Lambert law is developed. IR light is transmitted through mixed gas, and the light intensity with and without the agent present is measured. The intensity ratio is a function of the volume percentage of Halon 1301, and the voltage output of the detector is proportional to light intensity. As such, the relationship between the volume percentage and voltage ratio can be established. The concentration measurement system shows a relative error of the system less than ±2.50%, and a full scale error within 1.20%. This work also discusses the effect of temperature and relative humidity (RH) on the calibration. The experimental results of voltage ratio versus Halon 1301 volume percentage relationship show that the voltage ratio drops significantly as temperature rises from 25 to 100 °C, and it decreases as RH rises from 0% to 100%.
Metal Ion Sensor with Catalytic DNA in a Nanofluidic Intelligent Processor
2011-12-01
attributed to decreased diffusion and less active DNAzyme complex because of pore constraints. Uncleavable Alexa546 intensity is shown in gray ...is shown in gray , cleavable fluorescein in green, and the ratio of Fl/Alexa in red. Error bars represent one standard deviation of four independent...higher concentrations inhibiting cleaved fragment release. Uncleavable Alexa 546 intensity is shown in gray , cleavable fluorescein in green, and the
Wang, Qin; Zhou, Xing-Yu; Guo, Guang-Can
2016-01-01
In this paper, we put forward a new approach towards realizing measurement-device-independent quantum key distribution with passive heralded single-photon sources. In this approach, both Alice and Bob prepare the parametric down-conversion source, where the heralding photons are labeled according to different types of clicks from the local detectors, and the heralded ones can correspondingly be marked with different tags at the receiver’s side. Then one can obtain four sets of data through using only one-intensity of pump light by observing different kinds of clicks of local detectors. By employing the newest formulae to do parameter estimation, we could achieve very precise prediction for the two-single-photon pulse contribution. Furthermore, by carrying out corresponding numerical simulations, we compare the new method with other practical schemes of measurement-device-independent quantum key distribution. We demonstrate that our new proposed passive scheme can exhibit remarkable improvement over the conventional three-intensity decoy-state measurement-device-independent quantum key distribution with either heralded single-photon sources or weak coherent sources. Besides, it does not need intensity modulation and can thus diminish source-error defects existing in several other active decoy-state methods. Therefore, if taking intensity modulating errors into account, our new method will show even more brilliant performance. PMID:27759085
Anisotropic scattering of discrete particle arrays.
Paul, Joseph S; Fu, Wai Chong; Dokos, Socrates; Box, Michael
2010-05-01
Far-field intensities of light scattered from a linear centro-symmetric array illuminated by a plane wave of incident light are estimated at a series of detector angles. The intensities are computed from the superposition of E-fields scattered by the individual array elements. An average scattering phase function is used to model the scattered fields of individual array elements. The nature of scattering from the array is investigated using an image (theta-phi plot) of the far-field intensities computed at a series of locations obtained by rotating the detector angle from 0 degrees to 360 degrees, corresponding to each angle of incidence in the interval [0 degrees 360 degrees]. The diffraction patterns observed from the theta-Phi plot are compared with those for isotropic scattering. In the absence of prior information on the array geometry, the intensities corresponding to theta-Phi pairs satisfying the Bragg condition are used to estimate the phase function. An algorithmic procedure is presented for this purpose and tested using synthetic data. The relative error between estimated and theoretical values of the phase function is shown to be determined by the mean spacing factor, the number of elements, and the far-field distance. An empirical relationship is presented to calculate the optimal far-field distance for a given specification of the percentage error.
Jahng, Seungmin; Wood, Phillip K.
2017-01-01
Intensive longitudinal studies, such as ecological momentary assessment studies using electronic diaries, are gaining popularity across many areas of psychology. Multilevel models (MLMs) are most widely used analytical tools for intensive longitudinal data (ILD). Although ILD often have individually distinct patterns of serial correlation of measures over time, inferences of the fixed effects, and random components in MLMs are made under the assumption that all variance and autocovariance components are homogenous across individuals. In the present study, we introduced a multilevel model with Cholesky transformation to model ILD with individually heterogeneous covariance structure. In addition, the performance of the transformation method and the effects of misspecification of heterogeneous covariance structure were investigated through a Monte Carlo simulation. We found that, if individually heterogeneous covariances are incorrectly assumed as homogenous independent or homogenous autoregressive, MLMs produce highly biased estimates of the variance of random intercepts and the standard errors of the fixed intercept and the fixed effect of a level 2 covariate when the average autocorrelation is high. For intensive longitudinal data with individual specific residual covariance, the suggested transformation method showed lower bias in those estimates than the misspecified models when the number of repeated observations within individuals is 50 or more. PMID:28286490
Lee, C Matthew; Gorelick, Mark; Mendoza, Albert
2011-12-01
The purpose of this study was to examine the accuracy of the ePulse Personal Fitness Assistant, a forearm-worn device that provides measures of heart rate and estimates energy expenditure. Forty-six participants engaged in 4-minute periods of standing, 2.0 mph walking, 3.5 mph walking, 4.5 mph jogging, and 6.0 mph running. Heart rate and energy expenditure were simultaneously recorded at 60-second intervals using the ePulse, an electrocardiogram (EKG), and indirect calorimetry. The heart rates obtained from the ePulse were highly correlated (intraclass correlation coefficients [ICCs] ≥0.85) with those from the EKG during all conditions. The typical errors progressively increased with increasing exercise intensity but were <5 bpm only during rest and 2.0 mph. Energy expenditure from the ePulse was poorly correlated with indirect calorimetry (ICCs: 0.01-0.36) and the typical errors for energy expenditure ranged from 0.69-2.97 kcal · min(-1), progressively increasing with exercise intensity. These data suggest that the ePulse Personal Fitness Assistant is a valid device for monitoring heart rate at rest and low-intensity exercise, but becomes less accurate as exercise intensity increases. However, it does not appear to be a valid device to estimate energy expenditure during exercise.
High-Order Model and Dynamic Filtering for Frame Rate Up-Conversion.
Bao, Wenbo; Zhang, Xiaoyun; Chen, Li; Ding, Lianghui; Gao, Zhiyong
2018-08-01
This paper proposes a novel frame rate up-conversion method through high-order model and dynamic filtering (HOMDF) for video pixels. Unlike the constant brightness and linear motion assumptions in traditional methods, the intensity and position of the video pixels are both modeled with high-order polynomials in terms of time. Then, the key problem of our method is to estimate the polynomial coefficients that represent the pixel's intensity variation, velocity, and acceleration. We propose to solve it with two energy objectives: one minimizes the auto-regressive prediction error of intensity variation by its past samples, and the other minimizes video frame's reconstruction error along the motion trajectory. To efficiently address the optimization problem for these coefficients, we propose the dynamic filtering solution inspired by video's temporal coherence. The optimal estimation of these coefficients is reformulated into a dynamic fusion of the prior estimate from pixel's temporal predecessor and the maximum likelihood estimate from current new observation. Finally, frame rate up-conversion is implemented using motion-compensated interpolation by pixel-wise intensity variation and motion trajectory. Benefited from the advanced model and dynamic filtering, the interpolated frame has much better visual quality. Extensive experiments on the natural and synthesized videos demonstrate the superiority of HOMDF over the state-of-the-art methods in both subjective and objective comparisons.
Shaw, M; Singh, S
2015-04-01
Diagnostic error has implications for both clinical outcome and resource utilisation, and may often be traced to impaired data gathering, processing or synthesis because of the influence of cognitive bias. Factors inherent to the intensive/acute care environment afford multiple additional opportunities for such errors to occur. This article illustrates many of these with reference to a case encountered on our intensive care unit. Strategies to improve completeness of data gathering, processing and synthesis in the acute care environment are critically appraised in the context of early detection and amelioration of cognitive bias. These include reflection, targeted simulation training and the integration of social media and IT based aids in complex diagnostic processes. A framework which can be quickly and easily employed in a variety of clinical environments is then presented. © 2015 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Cornwell, Donald M., Jr.; Saif, Babak N.
1991-01-01
The spatial pointing angle and far field beamwidth of a high-power semiconductor laser are characterized as a function of CW power and also as a function of temperature. The time-averaged spatial pointing angle and spatial lobe width were measured under intensity-modulated conditions. The measured pointing deviations are determined to be well within the pointing requirements of the NASA Laser Communications Transceiver (LCT) program. A computer-controlled Mach-Zehnder phase-shifter interferometer is used to characterize the wavefront quality of the laser. The rms phase error over the entire pupil was measured as a function of CW output power. Time-averaged measurements of the wavefront quality are also made under intensity-modulated conditions. The measured rms phase errors are determined to be well within the wavefront quality requirements of the LCT program.
Liquid crystal point diffraction interferometer. Ph.D. Thesis - Arizona Univ., 1995
NASA Technical Reports Server (NTRS)
Mercer, Carolyn R.
1995-01-01
A new instrument, the liquid crystal point diffraction-interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with very high data density and with automated data reduction. This dissertation describes the theory of both the PDI and liquid crystal phase control. The design considerations for the LCPDI are presented, including manufacturing considerations. The operation and performance of the LCPDI are discussed, including sections regarding alignment, calibration, and amplitude modulation effects. The LCPDI is then demonstrated using two phase objects: defocus difference wavefront, and a temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to theoretical or independently measured results and show excellent agreement. A computer simulation of the LCPDI was performed to verify the source of observed periodic phase measurement error. The error stems from intensity variations caused by dye molecules rotating within the liquid crystal layer. Methods are discussed for reducing this error. Algorithms are presented which reduce this error; they are also useful for any phase-stepping interferometer that has unwanted intensity fluctuations, such as those caused by unregulated lasers.
2012-10-26
the need for alignment. We have also demonstrated the use of this technique with various materials as masks for silk biopolymer RIE processing and a...project. The automatization of silk solution was developed. Examination of different processing conditions for the raw material showed promise for...higher durability and higher flexibility optical substrates. Progress on interfaces was solidified. The previous findings on silk -metal interfaces
2012-08-01
dominates the global market for idealized media images. The world’s largest film industry today is actu- ally India’s Bollywood, and exports of Bol- lywood...Nigeria’s “Nollywood” is the world’s second most productive film industry .26 Like Bollywood films, Nollywood movies feature love sto- ries
ERIC on Compact Disc (CD-ROM). A Case Study.
ERIC Educational Resources Information Center
Brandhorst, Ted
ORI, Inc., and SilverPlatter, Inc., have joined together in a joint venture to offer the ERIC database to the public on compact laser disc (CD-ROM). Data from both "Resources in Education" (RIE) and "Current Index to Journals in Education" (CIJE) will be offered on a single disc from January 1983 to the present (with the disc…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kippen, Karen Elizabeth; Montoya, Donald Raymond
For more than 20 years the science and engineering capabilities of the nation’s Stockpile Stewardship Program have allowed the United States to sustain a safe, secure, and effective nuclear deterrent. Most of the problems identifi ed within the nuclear stockpile are related to its aging materials. MaRIE will advance this record of excellence in addressing such materials problems.
Weaving RIE with "Te Whariki": Re-Thinking Family Involvement in Assessment of Learning Dispositions
ERIC Educational Resources Information Center
Cooper, Maria; Hedges, Helen; Dixon, Helen
2014-01-01
Families play important roles in children's learning. Yet, teachers' values and beliefs may sway how families may participate in assessment of their child's learning within early childhood education. This paper reports on a qualitative case study in a New Zealand early childhood setting that explored teachers' views about involving families in…
Effective of Microwave-KOH Pretreatment on Enzymatic Hydrolysis of Bamboo
Zhiqiang Li; Zehui Jiang; Yan Yu; Zhiyong Cai
2012-01-01
Bamboo, with its advantages of fast growth, short renovation, easy propagation and rich in cellulose and hemicellulose, is a potential feedstock for bioethanol or other biofuels production. The objective of this study was to examine the fea- sibility of microwave assistant KOH pretreatments to enhance enzymatic hydrolysis of bamboo. Pretreatment was car- ried out by...
Comparing errors in ED computer-assisted vs conventional pediatric drug dosing and administration.
Yamamoto, Loren; Kanemori, Joan
2010-06-01
Compared to fixed-dose single-vial drug administration in adults, pediatric drug dosing and administration requires a series of calculations, all of which are potentially error prone. The purpose of this study is to compare error rates and task completion times for common pediatric medication scenarios using computer program assistance vs conventional methods. Two versions of a 4-part paper-based test were developed. Each part consisted of a set of medication administration and/or dosing tasks. Emergency department and pediatric intensive care unit nurse volunteers completed these tasks using both methods (sequence assigned to start with a conventional or a computer-assisted approach). Completion times, errors, and the reason for the error were recorded. Thirty-eight nurses completed the study. Summing the completion of all 4 parts, the mean conventional total time was 1243 seconds vs the mean computer program total time of 879 seconds (P < .001). The conventional manual method had a mean of 1.8 errors vs the computer program with a mean of 0.7 errors (P < .001). Of the 97 total errors, 36 were due to misreading the drug concentration on the label, 34 were due to calculation errors, and 8 were due to misplaced decimals. Of the 36 label interpretation errors, 18 (50%) occurred with digoxin or insulin. Computerized assistance reduced errors and the time required for drug administration calculations. A pattern of errors emerged, noting that reading/interpreting certain drug labels were more error prone. Optimizing the layout of drug labels could reduce the error rate for error-prone labels. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Danielson, Patrick; Yang, Limin; Jin, Suming; Homer, Collin G.; Napton, Darrell
2016-01-01
We developed a method that analyzes the quality of the cultivated cropland class mapped in the USA National Land Cover Database (NLCD) 2006. The method integrates multiple geospatial datasets and a Multi Index Integrated Change Analysis (MIICA) change detection method that captures spectral changes to identify the spatial distribution and magnitude of potential commission and omission errors for the cultivated cropland class in NLCD 2006. The majority of the commission and omission errors in NLCD 2006 are in areas where cultivated cropland is not the most dominant land cover type. The errors are primarily attributed to the less accurate training dataset derived from the National Agricultural Statistics Service Cropland Data Layer dataset. In contrast, error rates are low in areas where cultivated cropland is the dominant land cover. Agreement between model-identified commission errors and independently interpreted reference data was high (79%). Agreement was low (40%) for omission error comparison. The majority of the commission errors in the NLCD 2006 cultivated crops were confused with low-intensity developed classes, while the majority of omission errors were from herbaceous and shrub classes. Some errors were caused by inaccurate land cover change from misclassification in NLCD 2001 and the subsequent land cover post-classification process.
NASA Astrophysics Data System (ADS)
Arndt, U. W.; Willis, B. T. M.
2009-06-01
Preface; Acknowledgements; Part I. Introduction; Part II. Diffraction Geometry; Part III. The Design of Diffractometers; Part IV. Detectors; Part V. Electronic Circuits; Part VI. The Production of the Primary Beam (X-rays); Part VII. The Production of the Primary Beam (Neutrons); Part VIII. The Background; Part IX. Systematic Errors in Measuring Relative Integrated Intensities; Part X. Procedure for Measuring Integrated Intensities; Part XI. Derivation and Accuracy of Structure Factors; Part XII. Computer Programs and On-line Control; Appendix; References; Index.
Common errors of drug administration in infants: causes and avoidance.
Anderson, B J; Ellis, J F
1999-01-01
Drug administration errors are common in infants. Although the infant population has a high exposure to drugs, there are few data concerning pharmacokinetics or pharmacodynamics, or the influence of paediatric diseases on these processes. Children remain therapeutic orphans. Formulations are often suitable only for adults; in addition, the lack of maturation of drug elimination processes, alteration of body composition and influence of size render the calculation of drug doses complex in infants. The commonest drug administration error in infants is one of dose, and the commonest hospital site for this error is the intensive care unit. Drug errors are a consequence of system error, and preventive strategies are possible through system analysis. The goal of a zero drug error rate should be aggressively sought, with systems in place that aim to eliminate the effects of inevitable human error. This involves review of the entire system from drug manufacture to drug administration. The nuclear industry, telecommunications and air traffic control services all practise error reduction policies with zero error as a clear goal, not by finding fault in the individual, but by identifying faults in the system and building into that system mechanisms for picking up faults before they occur. Such policies could be adapted to medicine using interventions both specific (the production of formulations which are for children only and clearly labelled, regular audit by pharmacists, legible prescriptions, standardised dose tables) and general (paediatric drug trials, education programmes, nonpunitive error reporting) to reduce the number of errors made in giving medication to infants.
Convective Weather Forecast Accuracy Analysis at Center and Sector Levels
NASA Technical Reports Server (NTRS)
Wang, Yao; Sridhar, Banavar
2010-01-01
This paper presents a detailed convective forecast accuracy analysis at center and sector levels. The study is aimed to provide more meaningful forecast verification measures to aviation community, as well as to obtain useful information leading to the improvements in the weather translation capacity models. In general, the vast majority of forecast verification efforts over past decades have been on the calculation of traditional standard verification measure scores over forecast and observation data analyses onto grids. These verification measures based on the binary classification have been applied in quality assurance of weather forecast products at the national level for many years. Our research focuses on the forecast at the center and sector levels. We calculate the standard forecast verification measure scores for en-route air traffic centers and sectors first, followed by conducting the forecast validation analysis and related verification measures for weather intensities and locations at centers and sectors levels. An approach to improve the prediction of sector weather coverage by multiple sector forecasts is then developed. The weather severe intensity assessment was carried out by using the correlations between forecast and actual weather observation airspace coverage. The weather forecast accuracy on horizontal location was assessed by examining the forecast errors. The improvement in prediction of weather coverage was determined by the correlation between actual sector weather coverage and prediction. observed and forecasted Convective Weather Avoidance Model (CWAM) data collected from June to September in 2007. CWAM zero-minute forecast data with aircraft avoidance probability of 60% and 80% are used as the actual weather observation. All forecast measurements are based on 30-minute, 60- minute, 90-minute, and 120-minute forecasts with the same avoidance probabilities. The forecast accuracy analysis for times under one-hour showed that the errors in intensity and location for center forecast are relatively low. For example, 1-hour forecast intensity and horizontal location errors for ZDC center were about 0.12 and 0.13. However, the correlation between sector 1-hour forecast and actual weather coverage was weak, for sector ZDC32, about 32% of the total variation of observation weather intensity was unexplained by forecast; the sector horizontal location error was about 0.10. The paper also introduces an approach to estimate the sector three-dimensional actual weather coverage by using multiple sector forecasts, which turned out to produce better predictions. Using Multiple Linear Regression (MLR) model for this approach, the correlations between actual observation and the multiple sector forecast model prediction improved by several percents at 95% confidence level in comparison with single sector forecast.
BPM CALIBRATION INDEPENDENT LHC OPTICS CORRECTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
CALAGA,R.; TOMAS, R.; GIOVANNOZZI, M.
2007-06-25
The tight mechanical aperture for the LHC imposes severe constraints on both the beta and dispersion beating. Robust techniques to compensate these errors are critical for operation of high intensity beams in the LHC. We present simulations using realistic errors from magnet measurements and alignment tolerances in the presence of BPM noise. Correction reveals that the use of BPM calibration and model independent observables are key ingredients to accomplish optics correction. Experiments at RHIC to verify the algorithms for optics correction are also presented.
Laser Velocimeter Measurements and Analysis in Turbulent Flows with Combustion. Part 2.
1983-07-01
sampling error for 63 this sample size. Mean velocities and turbulence intensi- ties were found to be statistically accurate to ± 1 % and 13%, respectively...Although the statist - ical error was found to be rather small (± 1 % for mean velo- cities and 13% for turbulence intensities), there can be additional...34Computational and Experimental Study of a Captive Annular Eddy," Journal of Fluid Mechanics, Vol. 28, pt. 1 , pp. 43-63, 12 April, 1967. 152 REFERENCES (con’d
The next organizational challenge: finding and addressing diagnostic error.
Graber, Mark L; Trowbridge, Robert; Myers, Jennifer S; Umscheid, Craig A; Strull, William; Kanter, Michael H
2014-03-01
Although health care organizations (HCOs) are intensely focused on improving the safety of health care, efforts to date have almost exclusively targeted treatment-related issues. The literature confirms that the approaches HCOs use to identify adverse medical events are not effective in finding diagnostic errors, so the initial challenge is to identify cases of diagnostic error. WHY HEALTH CARE ORGANIZATIONS NEED TO GET INVOLVED: HCOs are preoccupied with many quality- and safety-related operational and clinical issues, including performance measures. The case for paying attention to diagnostic errors, however, is based on the following four points: (1) diagnostic errors are common and harmful, (2) high-quality health care requires high-quality diagnosis, (3) diagnostic errors are costly, and (4) HCOs are well positioned to lead the way in reducing diagnostic error. FINDING DIAGNOSTIC ERRORS: Current approaches to identifying diagnostic errors, such as occurrence screens, incident reports, autopsy, and peer review, were not designed to detect diagnostic issues (or problems of omission in general) and/or rely on voluntary reporting. The realization that the existing tools are inadequate has spurred efforts to identify novel tools that could be used to discover diagnostic errors or breakdowns in the diagnostic process that are associated with errors. New approaches--Maine Medical Center's case-finding of diagnostic errors by facilitating direct reports from physicians and Kaiser Permanente's electronic health record--based reports that detect process breakdowns in the followup of abnormal findings--are described in case studies. By raising awareness and implementing targeted programs that address diagnostic error, HCOs may begin to play an important role in addressing the problem of diagnostic error.
Ogawa, Takahiro; Haseyama, Miki
2013-03-01
A missing texture reconstruction method based on an error reduction (ER) algorithm, including a novel estimation scheme of Fourier transform magnitudes is presented in this brief. In our method, Fourier transform magnitude is estimated for a target patch including missing areas, and the missing intensities are estimated by retrieving its phase based on the ER algorithm. Specifically, by monitoring errors converged in the ER algorithm, known patches whose Fourier transform magnitudes are similar to that of the target patch are selected from the target image. In the second approach, the Fourier transform magnitude of the target patch is estimated from those of the selected known patches and their corresponding errors. Consequently, by using the ER algorithm, we can estimate both the Fourier transform magnitudes and phases to reconstruct the missing areas.
Boundary identification and error analysis of shocked material images
NASA Astrophysics Data System (ADS)
Hock, Margaret; Howard, Marylesa; Cooper, Leora; Meehan, Bernard; Nelson, Keith
2017-06-01
To compute quantities such as pressure and velocity from laser-induced shock waves propagating through materials, high-speed images are captured and analyzed. Shock images typically display high noise and spatially-varying intensities, causing conventional analysis techniques to have difficulty identifying boundaries in the images without making significant assumptions about the data. We present a novel machine learning algorithm that efficiently segments, or partitions, images with high noise and spatially-varying intensities, and provides error maps that describe a level of uncertainty in the partitioning. The user trains the algorithm by providing locations of known materials within the image but no assumptions are made on the geometries in the image. The error maps are used to provide lower and upper bounds on quantities of interest, such as velocity and pressure, once boundaries have been identified and propagated through equations of state. This algorithm will be demonstrated on images of shock waves with noise and aberrations to quantify properties of the wave as it progresses. DOE/NV/25946-3126 This work was done by National Security Technologies, LLC, under Contract No. DE- AC52-06NA25946 with the U.S. Department of Energy and supported by the SDRD Program.
Evaluating video digitizer errors
NASA Astrophysics Data System (ADS)
Peterson, C.
2016-01-01
Analog output video cameras remain popular for recording meteor data. Although these cameras uniformly employ electronic detectors with fixed pixel arrays, the digitization process requires resampling the horizontal lines as they are output in order to reconstruct the pixel data, usually resulting in a new data array of different horizontal dimensions than the native sensor. Pixel timing is not provided by the camera, and must be reconstructed based on line sync information embedded in the analog video signal. Using a technique based on hot pixels, I present evidence that jitter, sync detection, and other timing errors introduce both position and intensity errors which are not present in cameras which internally digitize their sensors and output the digital data directly.
Bae, Youngchul
2016-05-23
An optical sensor such as a laser range finder (LRF) or laser displacement meter (LDM) uses reflected and returned laser beam from a target. The optical sensor has been mainly used to measure the distance between a launch position and the target. However, optical sensor based LRF and LDM have numerous and various errors such as statistical errors, drift errors, cyclic errors, alignment errors and slope errors. Among these errors, an alignment error that contains measurement error for the strength of radiation of returned laser beam from the target is the most serious error in industrial optical sensors. It is caused by the dependence of the measurement offset upon the strength of radiation of returned beam incident upon the focusing lens from the target. In this paper, in order to solve these problems, we propose a novel method for the measurement of the output of direct current (DC) voltage that is proportional to the strength of radiation of returned laser beam in the received avalanche photo diode (APD) circuit. We implemented a measuring circuit that is able to provide an exact measurement of reflected laser beam. By using the proposed method, we can measure the intensity or strength of radiation of laser beam in real time and with a high degree of precision.
Bae, Youngchul
2016-01-01
An optical sensor such as a laser range finder (LRF) or laser displacement meter (LDM) uses reflected and returned laser beam from a target. The optical sensor has been mainly used to measure the distance between a launch position and the target. However, optical sensor based LRF and LDM have numerous and various errors such as statistical errors, drift errors, cyclic errors, alignment errors and slope errors. Among these errors, an alignment error that contains measurement error for the strength of radiation of returned laser beam from the target is the most serious error in industrial optical sensors. It is caused by the dependence of the measurement offset upon the strength of radiation of returned beam incident upon the focusing lens from the target. In this paper, in order to solve these problems, we propose a novel method for the measurement of the output of direct current (DC) voltage that is proportional to the strength of radiation of returned laser beam in the received avalanche photo diode (APD) circuit. We implemented a measuring circuit that is able to provide an exact measurement of reflected laser beam. By using the proposed method, we can measure the intensity or strength of radiation of laser beam in real time and with a high degree of precision. PMID:27223291
Kiymaz, Dilek; Koç, Zeliha
2018-03-01
To determine individual and professional factors affecting the tendency of emergency unit nurses to make medical errors and their attitudes towards these errors in Turkey. Compared with other units, the emergency unit is an environment where there is an increased tendency for making medical errors due to its intensive and rapid pace, noise and complex and dynamic structure. A descriptive cross-sectional study. The study was carried out from 25 July 2014-16 September 2015 with the participation of 284 nurses who volunteered to take part in the study. Data were gathered using the data collection survey for nurses, the Medical Error Tendency Scale and the Medical Error Attitude Scale. It was determined that 40.1% of the nurses previously witnessed medical errors, 19.4% made a medical error in the last year, 17.6% of medical errors were caused by medication errors where the wrong medication was administered in the wrong dose, and none of the nurses filled out a case report form about the medical errors they made. Regarding the factors that caused medical errors in the emergency unit, 91.2% of the nurses stated excessive workload as a cause; 85.1% stated an insufficient number of nurses; and 75.4% stated fatigue, exhaustion and burnout. The study showed that nurses who loved their job were satisfied with their unit and who always worked during day shifts had a lower medical error tendency. It is suggested to consider the following actions: increase awareness about medical errors, organise training to reduce errors in medication administration, develop procedures and protocols specific to the emergency unit health care and create an environment which is not punitive wherein nurses can safely report medical errors. © 2017 John Wiley & Sons Ltd.
Suárez Rodríguez, David; del Valle Soto, Miguel
2017-01-01
Background The aim of this study is to find the differences between two specific interval exercises. We begin with the hypothesis that the use of microintervals of work and rest allow for greater intensity of play and a reduction in fatigue. Methods Thirteen competition-level male tennis players took part in two interval training exercises comprising nine 2 min series, which consisted of hitting the ball with cross-court forehand and backhand shots, behind the service box. One was a high-intensity interval training (HIIT), made up of periods of continuous work lasting 2 min, and the other was intermittent interval training (IIT), this time with intermittent 2 min intervals, alternating periods of work with rest periods. Average heart rate (HR) and lactate levels were registered in order to observe the physiological intensity of the two exercises, along with the Borg Scale results for perceived exertion and the number of shots and errors in order to determine the intensity achieved and the degree of fatigue throughout the exercise. Results There were no significant differences in the average heart rate, lactate or the Borg Scale. Significant differences were registered, on the other hand, with a greater number of shots in the first two HIIT series (series 1 p>0.009; series 2 p>0.056), but not in the third. The number of errors was significantly lower in all the IIT series (series 1 p<0.035; series 2 p<0.010; series 3 p<0.001). Conclusion Our study suggests that high-intensity intermittent training allows for greater intensity of play in relation to the real time spent on the exercise, reduced fatigue levels and the maintaining of greater precision in specific tennis-related exercises. PMID:29021912
Száz, Dénes; Farkas, Alexandra; Blahó, Miklós; Barta, András; Egri, Ádám; Kretzer, Balázs; Hegedüs, Tibor; Jäger, Zoltán; Horváth, Gábor
2016-01-01
According to an old but still unproven theory, Viking navigators analysed the skylight polarization with dichroic cordierite or tourmaline, or birefringent calcite sunstones in cloudy/foggy weather. Combining these sunstones with their sun-dial, they could determine the position of the occluded sun, from which the geographical northern direction could be guessed. In psychophysical laboratory experiments, we studied the accuracy of the first step of this sky-polarimetric Viking navigation. We measured the adjustment error e of rotatable cordierite, tourmaline and calcite crystals when the task was to determine the direction of polarization of white light as a function of the degree of linear polarization p. From the obtained error functions e(p), the thresholds p* above which the first step can still function (i.e. when the intensity change seen through the rotating analyser can be sensed) were derived. Cordierite is about twice as reliable as tourmaline. Calcite sunstones have smaller adjustment errors if the navigator looks for that orientation of the crystal where the intensity difference between the two spots seen in the crystal is maximal, rather than minimal. For higher p (greater than p crit) of incident light, the adjustment errors of calcite are larger than those of the dichroic cordierite (p crit=20%) and tourmaline (p crit=45%), while for lower p (less than p crit) calcite usually has lower adjustment errors than dichroic sunstones. We showed that real calcite crystals are not as ideal sunstones as it was believed earlier, because they usually contain scratches, impurities and crystal defects which increase considerably their adjustment errors. Thus, cordierite and tourmaline can also be at least as good sunstones as calcite. Using the psychophysical e(p) functions and the patterns of the degree of skylight polarization measured by full-sky imaging polarimetry, we computed how accurately the northern direction can be determined with the use of the Viking sun-dial under 10 different sky conditions at 61° latitude, which was one of the main Viking sailing routes. According to our expermiments, under clear skies, using calcite or cordierite or tourmaline sunstones, Viking sailors could navigate with net orientation errors [Formula: see text]. Under overcast conditions, their net navigation error depends on the sunstone type: [Formula: see text], [Formula: see text] and [Formula: see text].
Suppression of Striatal Prediction Errors by the Prefrontal Cortex in Placebo Hypoalgesia.
Schenk, Lieven A; Sprenger, Christian; Onat, Selim; Colloca, Luana; Büchel, Christian
2017-10-04
Classical learning theories predict extinction after the discontinuation of reinforcement through prediction errors. However, placebo hypoalgesia, although mediated by associative learning, has been shown to be resistant to extinction. We tested the hypothesis that this is mediated by the suppression of prediction error processing through the prefrontal cortex (PFC). We compared pain modulation through treatment cues (placebo hypoalgesia, treatment context) with pain modulation through stimulus intensity cues (stimulus context) during functional magnetic resonance imaging in 48 male and female healthy volunteers. During acquisition, our data show that expectations are correctly learned and that this is associated with prediction error signals in the ventral striatum (VS) in both contexts. However, in the nonreinforced test phase, pain modulation and expectations of pain relief persisted to a larger degree in the treatment context, indicating that the expectations were not correctly updated in the treatment context. Consistently, we observed significantly stronger neural prediction error signals in the VS in the stimulus context compared with the treatment context. A connectivity analysis revealed negative coupling between the anterior PFC and the VS in the treatment context, suggesting that the PFC can suppress the expression of prediction errors in the VS. Consistent with this, a participant's conceptual views and beliefs about treatments influenced the pain modulation only in the treatment context. Our results indicate that in placebo hypoalgesia contextual treatment information engages prefrontal conceptual processes, which can suppress prediction error processing in the VS and lead to reduced updating of treatment expectancies, resulting in less extinction of placebo hypoalgesia. SIGNIFICANCE STATEMENT In aversive and appetitive reinforcement learning, learned effects show extinction when reinforcement is discontinued. This is thought to be mediated by prediction errors (i.e., the difference between expectations and outcome). Although reinforcement learning has been central in explaining placebo hypoalgesia, placebo hypoalgesic effects show little extinction and persist after the discontinuation of reinforcement. Our results support the idea that conceptual treatment beliefs bias the neural processing of expectations in a treatment context compared with a more stimulus-driven processing of expectations with stimulus intensity cues. We provide evidence that this is associated with the suppression of prediction error processing in the ventral striatum by the prefrontal cortex. This provides a neural basis for persisting effects in reinforcement learning and placebo hypoalgesia. Copyright © 2017 the authors 0270-6474/17/379715-09$15.00/0.
Uranus occults SAO158687. [stellar occultation and planetary parametric observation
NASA Technical Reports Server (NTRS)
Elliot, J. L.; Veverka, J.; Millis, R. L.
1977-01-01
Experience gained in obtaining atmospheric parameters, oblatenesses, and diameters of Jupiter and Mars from recent stellar occultations by these planets is used to predict what can be learned from the March 1977 occultation of the star SAO158687 by Uranus. The spectra of this star and Uranus are compared to indicate the relative instrument intensities of the two objects, the four passbands where the relative intensities are most nearly equal are listed, and expected photon fluxes from the star are computed on the assumption that it has UBVRI colors appropriate for a K5 main-sequence object. It is shown that low photon noise errors can be achieved by choosing appropriate passbands for observation, and the rms error expected for the Uranus temperature profiles obtained from the occultation light curves is calculated. It is suggested that observers of this occultation should record their data digitally for optimum time resolution.
NASA Astrophysics Data System (ADS)
Hu, Junbao; Meng, Xin; Wei, Qi; Kong, Yan; Jiang, Zhilong; Xue, Liang; Liu, Fei; Liu, Cheng; Wang, Shouyu
2018-03-01
Wide-field microscopy is commonly used for sample observations in biological research and medical diagnosis. However, the tilting error induced by the oblique location of the image recorder or the sample, as well as the inclination of the optical path often deteriorates the imaging quality. In order to eliminate the tilting in microscopy, a numerical tilting compensation technique based on wavefront sensing using transport of intensity equation method is proposed in this paper. Both the provided numerical simulations and practical experiments prove that the proposed technique not only accurately determines the tilting angle with simple setup and procedures, but also compensates the tilting error for imaging quality improvement even in the large tilting cases. Considering its simple systems and operations, as well as image quality improvement capability, it is believed the proposed method can be applied for tilting compensation in the optical microscopy.
NASA Astrophysics Data System (ADS)
El-Nahal, Fady I.
2017-01-01
We investigate a wavelength-division-multiplexing passive optical network (WDM-PON) with centralized lightwave and direct detection. The system is demonstrated for symmetric 10 Gbit/s differential phase-shift keying (DPSK) downstream signals and on-off keying (OOK) upstream signals, respectively. A wavelength reused scheme is employed to carry the upstream data by using a reflective semiconductor optical amplifier (RSOA) as an intensity modulator at the optical network unit (ONU). The constant-intensity property of the DPSK modulation format can keep high extinction ratio ( ER) of downstream signal and reduce the crosstalk to the upstream signal. The bit error rate ( BER) performance of our scheme shows that the proposed 10 Gbit/s symmetric WDM-PON can achieve error free transmission over 25-km-long fiber transmission with low power penalty.
Efficient color correction method for smartphone camera-based health monitoring application.
Duc Dang; Chae Ho Cho; Daeik Kim; Oh Seok Kwon; Jo Woon Chong
2017-07-01
Smartphone health monitoring applications are recently highlighted due to the rapid development of hardware and software performance of smartphones. However, color characteristics of images captured by different smartphone models are dissimilar each other and this difference may give non-identical health monitoring results when the smartphone health monitoring applications monitor physiological information using their embedded smartphone cameras. In this paper, we investigate the differences in color properties of the captured images from different smartphone models and apply a color correction method to adjust dissimilar color values obtained from different smartphone cameras. Experimental results show that the color corrected images using the correction method provide much smaller color intensity errors compared to the images without correction. These results can be applied to enhance the consistency of smartphone camera-based health monitoring applications by reducing color intensity errors among the images obtained from different smartphones.
Performance of a Combined System Using an X-Ray FEL Oscillator and a High-Gain FEL Amplifier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, L.; Lindberg, R.; Kim, K. -J.
The LCLS-II at SLAC will feature a 4 GeV CW superconducting (SC) RF linac [1] that can potentially drive a 5th harmonic X-Ray FEL Oscillator (XFELO) to produce fully coherent, 1 MW photon pulses with a 5 meV bandwidth at 14.4 keV [2]. The XFELO output can serve as the input seed signal for a high-gain FEL amplifier employing fs electron beams from the normal conducting SLAC linac, thereby generating coherent, fs x-ray pulses with TW peak powers using a tapered undulator after saturation [3]. Coherent, intense output at several tens of keV will also be feasible if one considersmore » a harmonic generation scheme. Thus, one can potentially reach the 42 keV photon energy required for the MaRIE project [4] by beginning with an XFELO operating at the 3rd harmonic to produce 14.0 keV photons using a 12 GeV SCRF linac, and then subsequently using the high-gain harmonic generation scheme to generate and amplify the 3th harmonic at 42 keV [5]. We report extensive GINGER simulations that determine an optimized parameter set for the combined system.« less
Highly Efficient, All-Dielectric Huygens Metasurfaces
NASA Astrophysics Data System (ADS)
Ollanik, Adam; Farrar-Foley, Nick; Smith, Jake; Escarra, Matthew
Demonstration of the control of light by the introduction of abrupt phase discontinuities across a subwavelength scale has opened the doors to a new level of wavefront control. All-dielectric Huygens metasurfaces hold significant promise due to their dramatically improved efficiency over plasmonic approaches. We present the successful design, computational modeling, and experimental realization of all-dielectric transmissive Huygens metasurfaces capable of deflection efficiency >90%. Dielectric Huygens sources, taking advantage of spectrally aligned electric and magnetic dipole resonances, are capable of tunable phase delay for transmitted light with near unity efficiency of forward scattering. Using ellipsoidal cylinder nanoantennas, we are able to manipulate the phase response and engineer a metasurface with a spatially gradient phase profile. Through careful design and optimization we mitigate the effects of inter-antenna coupling. We have designed and modeled metasurfaces demonstrating anomalous refraction with very high efficiency (>80%) for wavelength bands from the UV to the near-IR. These surfaces were designed using three distinct nanoantenna materials, Si, TiO2, and GaP, to demonstrate the flexibility of the technique. Experimentally, Si nanoantennas are fabricated using a combination of electron beam lithography and ICP/RIE-etching. Metasurfaces are characterized using a goniospectrometer capable of mapping light intensity on a cylindrical shell surrounding the metasurface.
Digital halftoning methods for selectively partitioning error into achromatic and chromatic channels
NASA Technical Reports Server (NTRS)
Mulligan, Jeffrey B.
1990-01-01
A method is described for reducing the visibility of artifacts arising in the display of quantized color images on CRT displays. The method is based on the differential spatial sensitivity of the human visual system to chromatic and achromatic modulations. Because the visual system has the highest spatial and temporal acuity for the luminance component of an image, a technique which will reduce luminance artifacts at the expense of introducing high-frequency chromatic errors is sought. A method based on controlling the correlations between the quantization errors in the individual phosphor images is explored. The luminance component is greatest when the phosphor errors are positively correlated, and is minimized when the phosphor errors are negatively correlated. The greatest effect of the correlation is obtained when the intensity quantization step sizes of the individual phosphors have equal luminances. For the ordered dither algorithm, a version of the method can be implemented by simply inverting the matrix of thresholds for one of the color components.
A Unified Data Assimilation Strategy for Regional Coupled Atmosphere-Ocean Prediction Systems
NASA Astrophysics Data System (ADS)
Xie, Lian; Liu, Bin; Zhang, Fuqing; Weng, Yonghui
2014-05-01
Improving tropical cyclone (TC) forecasts is a top priority in weather forecasting. Assimilating various observational data to produce better initial conditions for numerical models using advanced data assimilation techniques has been shown to benefit TC intensity forecasts, whereas assimilating large-scale environmental circulation into regional models by spectral nudging or Scale-Selective Data Assimilation (SSDA) has been demonstrated to improve TC track forecasts. Meanwhile, taking into account various air-sea interaction processes by high-resolution coupled air-sea modelling systems has also been shown to improve TC intensity forecasts. Despite the advances in data assimilation and air-sea coupled models, large errors in TC intensity and track forecasting remain. For example, Hurricane Nate (2011) has brought considerable challenge for the TC operational forecasting community, with very large intensity forecast errors (27, 25, and 40 kts for 48, 72, and 96 h, respectively) for the official forecasts. Considering the slow-moving nature of Hurricane Nate, it is reasonable to hypothesize that air-sea interaction processes played a critical role in the intensity change of the storm, and accurate representation of the upper ocean dynamics and thermodynamics is necessary to quantitatively describe the air-sea interaction processes. Currently, data assimilation techniques are generally only applied to hurricane forecasting in stand-alone atmospheric or oceanic model. In fact, most of the regional hurricane forecasting models only included data assimilation techniques for improving the initial condition of the atmospheric model. In such a situation, the benefit of adjustments in one model (atmospheric or oceanic) by assimilating observational data can be compromised by errors from the other model. Thus, unified data assimilation techniques for coupled air-sea modelling systems, which not only simultaneously assimilate atmospheric and oceanic observations into the coupled air-sea modelling system, but also nudging the large-scale environmental flow in the regional model towards global model forecasts are of increasing necessity. In this presentation, we will outline a strategy for an integrated approach in air-sea coupled data assimilation and discuss its benefits and feasibility from incremental results for select historical hurricane cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, R; Jee, K; Sharp, G
Purpose: Proton radiography, which images the patients with the same type of particles that they are to be treated with, is a promising approach for image guidance and range uncertainties reduction. This study aimed to realize quality proton radiography by measuring dose rate functions (DRF) in time domain using a single flat panel and retrieve water equivalent path length (WEPL) from them. Methods: An amorphous silicon flat panel (PaxScan™ 4030CB, Varian Medical Systems, Inc., Palo Alto, CA) was placed behind phantoms to measure DRFs from a proton beam modulated by the modulator wheel. To retrieve WEPL and RSP, calibration modelsmore » based on the intensity of DRFs only, root mean square (RMS) of DRFs only and the intensity weighted RMS were tested. The quality of obtained WEPL images (in terms of spatial resolution and level of details) and the accuracy of WEPL were compared. Results: RSPs for most of the Gammex phantom inserts were retrieved within ± 1% errors by calibration models based on the RMS and intensity weighted RMS. The mean percentage error for all inserts was reduced from 1.08% to 0.75% by matching intensity in the calibration model. In specific cases such as the insert with a titanium rod, the calibration model based on RMS only fails while the that based on intensity weighted RMS is still valid. The quality of retrieved WEPL images were significantly improved for calibration models including intensity matching. Conclusion: For the first time, a flat panel, which is readily available in the beamline for image guidance, was tested to acquire quality proton radiography with WEPL accurately retrieved from it. This technique is promising to be applied for image-guided proton therapy as well as patient specific RSP determination to reduce uncertainties of beam ranges.« less
Fischer, Melissa A; Mazor, Kathleen M; Baril, Joann; Alper, Eric; DeMarco, Deborah; Pugnaire, Michele
2006-01-01
CONTEXT Trainees are exposed to medical errors throughout medical school and residency. Little is known about what facilitates and limits learning from these experiences. OBJECTIVE To identify major factors and areas of tension in trainees' learning from medical errors. DESIGN, SETTING, AND PARTICIPANTS Structured telephone interviews with 59 trainees (medical students and residents) from 1 academic medical center. Five authors reviewed transcripts of audiotaped interviews using content analysis. RESULTS Trainees were aware that medical errors occur from early in medical school. Many had an intense emotional response to the idea of committing errors in patient care. Students and residents noted variation and conflict in institutional recommendations and individual actions. Many expressed role confusion regarding whether and how to initiate discussion after errors occurred. Some noted the conflict between reporting errors to seniors who were responsible for their evaluation. Learners requested more open discussion of actual errors and faculty disclosure. No students or residents felt that they learned better from near misses than from actual errors, and many believed that they learned the most when harm was caused. CONCLUSIONS Trainees are aware of medical errors, but remaining tensions may limit learning. Institutions can immediately address variability in faculty response and local culture by disseminating clear, accessible algorithms to guide behavior when errors occur. Educators should develop longitudinal curricula that integrate actual cases and faculty disclosure. Future multi-institutional work should focus on identified themes such as teaching and learning in emotionally charged situations, learning from errors and near misses and balance between individual and systems responsibility. PMID:16704381
1993-01-01
while using a sterile glass slide, held parallel to the monolayer, as a MATERIALS AND METHODS straight edge. Cultures were photographed using phase...contrastmicrosoyo tonoa~r movng ofi I spheria mi rocr rie bed ntI h CEILL CELIL CONTACT AND DIFFU SION 23 and cytokeratin 8 antibodies (refer to Figs. 4a
The Bridge: A Journal of Cross-Cultural Affairs; Summer 1976, Volume 1, Number 2.
ERIC Educational Resources Information Center
Reynolds, Collins, Ed.
This quarterly newsletter, announced in RIE on a one-time basis, investigates a different area of the world in each issue. It is intended for use by businessmen, government officials, and educators. Typical issues include feature articles highlighting problems of crossing cultural boundaries to teach, do business, or cope overseas and at home;…
2009-09-01
exploding foil initiator ( EFI ) type fuzes are being explored to...Acronyms Au gold Cr chromium Cu copper EFI exploding foil initiator BOE buffered oxide etch MEMS microelectromechanical systems RIE reactive ion...Patterning of Thick Parylene Films by Oxygen Plasma for Application as Exploding Foil Initiator Flyer Material by Eugene Zakar and Michael
ERIC Educational Resources Information Center
Wilder, Dolores J., Comp.; Hines, Rella, Comp.
The Tennessee Research Coordinating Unit (RCU) has implemented a computerized information retrieval system known as "Query," which allows for the retrieval of documents indexed in Research in Education (RIE), Current Index to Journals in Education (CIJE), and Abstracts of Instructional and Research Materials (AIM/ARM). The document…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Cris William
After the decision to end nuclear testing and the inception of the Stockpile Stewardship program, the condition of the stockpile was the primary mission driver. During the first two decades of stewardship, the primary program goal could be described as underwriting the Stockpile-to-Target Sequence (STS), the military requirements on the conditions the nuclear warheads needed to survive and still operate.
2000-09-01
fassent, si rien ne change par ailleurs. plus proche de l’ing~ni~rie du vivant . Une vdritable optimisation des 6ldinents de soutien logistique A bord...s souvent dans les arbres l’utilisation en service. fonctionnels, peuvent 8tre recueillies plus facilement dans un tableau crois6 avec les divers syst
1983-05-01
Mechanics, Vol. 43, S~ries E, No. 3, September 1976, pp. 387-395. 18. Warpinski , N. R. and Chow, W. L., "Base Pressure Associated With Incompressible...Flow Past Wedges at High Reynolds Numbers," J. of Applied Mechanics, Vol. 46, No. 3, September 1979. 19. Warpinski , N. R. and Chow, W. L., "Viscid
NASA Astrophysics Data System (ADS)
Berkhli, Mostafa; Vachard, Daniel
2002-01-01
New biostratigraphical data based on foraminifers, algae and pseudo-algae indicate that the limestone pebbles of the channelized polygenic conglomerates of the Migoumess formation contain Late Visean (V3b γ-V3c) assemblages. That confirms the Westphalian age attributed to this formation by Hollard [Zdt. Geol. Ges. 129 (1978) 495-512]. The Tournaisian age assigned to it by palynology [C. R. Acad. Sci. Paris, série II 310 (1990) 1573-1576] cannot be retained. The Tirhela formation, Late Visean and Serpukhovian (E1) in age, is coeval with the Akerchi formation [Berkhli, thèse d'État, 1999; Berkhli et al., J. Afr. Earth Sci. (accepté)]. The Idmarrach formation, mapped as a thrust sheet [C. R. Acad. Sci. Paris, série II 310 (1990) 1573-1576], is dated as Serpukhovian (E1) and its thrusting is consequently post-Serpukhovian. Palaeogeographic and geodynamic consequences are listed. To cite this article: M. Berkhli, D. Vachard, C. R. Geoscience 334 (2002) 67-72
The Relationship Between Work Commitment, Dynamic, and Medication Error.
Rezaiamin, Abdoolkarim; Pazokian, Marzieh; Zagheri Tafreshi, Mansoureh; Nasiri, Malihe
2017-05-01
Incidence of medication errors in intensive care unit (ICU) can cause irreparable damage for ICU patients. Therefore, it seems necessary to find the causes of medication errors in this section. Work commitment and dynamic might affect the incidence of medication errors in ICU. To assess the mentioned hypothesis, we performed a descriptive-analytical study which was carried out on 117 nurses working in ICU of educational hospitals in Tehran. Minick et al., Salyer et al., and Wakefield et al. scales were used for data gathering on work commitment, dynamic, and medication errors, respectively. Findings of the current study revealed that high work commitment in ICU nurses caused low number of medication errors, including intravenous and nonintravenous. We controlled the effects of confounding variables in detection of this relationship. In contrast, no significant association was found between work dynamic and different types of medication errors. Although the study did not observe any relationship between the dynamics and rate of medication errors, the training of nurses or nursing students to create a dynamic environment in hospitals can increase their interest in the profession and increase job satisfaction in them. Also they must have enough ability in work dynamic so that they don't confused and distracted result in frequent changes of orders, care plans, and procedures.
[A new method of processing quantitative PCR data].
Ke, Bing-Shen; Li, Guang-Yun; Chen, Shi-Min; Huang, Xiang-Yan; Chen, Ying-Jian; Xu, Jun
2003-05-01
Today standard PCR can't satisfy the need of biotechnique development and clinical research any more. After numerous dynamic research, PE company found there is a linear relation between initial template number and cycling time when the accumulating fluorescent product is detectable.Therefore,they developed a quantitative PCR technique to be used in PE7700 and PE5700. But the error of this technique is too great to satisfy the need of biotechnique development and clinical research. A better quantitative PCR technique is needed. The mathematical model submitted here is combined with the achievement of relative science,and based on the PCR principle and careful analysis of molecular relationship of main members in PCR reaction system. This model describes the function relation between product quantity or fluorescence intensity and initial template number and other reaction conditions, and can reflect the accumulating rule of PCR product molecule accurately. Accurate quantitative PCR analysis can be made use this function relation. Accumulated PCR product quantity can be obtained from initial template number. Using this model to do quantitative PCR analysis,result error is only related to the accuracy of fluorescence intensity or the instrument used. For an example, when the fluorescence intensity is accurate to 6 digits and the template size is between 100 to 1,000,000, the quantitative result accuracy will be more than 99%. The difference of result error is distinct using same condition,same instrument but different analysis method. Moreover,if the PCR quantitative analysis system is used to process data, it will get result 80 times of accuracy than using CT method.
TRAINING ERRORS AND RUNNING RELATED INJURIES: A SYSTEMATIC REVIEW
Buist, Ida; Sørensen, Henrik; Lind, Martin; Rasmussen, Sten
2012-01-01
Purpose: The purpose of this systematic review was to examine the link between training characteristics (volume, duration, frequency, and intensity) and running related injuries. Methods: A systematic search was performed in PubMed, Web of Science, Embase, and SportDiscus. Studies were included if they examined novice, recreational, or elite runners between the ages of 18 and 65. Exposure variables were training characteristics defined as volume, distance or mileage, time or duration, frequency, intensity, speed or pace, or similar terms. The outcome of interest was Running Related Injuries (RRI) in general or specific RRI in the lower extremity or lower back. Methodological quality was evaluated using quality assessment tools of 11 to 16 items. Results: After examining 4561 titles and abstracts, 63 articles were identified as potentially relevant. Finally, nine retrospective cohort studies, 13 prospective cohort studies, six case-control studies, and three randomized controlled trials were included. The mean quality score was 44.1%. Conflicting results were reported on the relationships between volume, duration, intensity, and frequency and RRI. Conclusion: It was not possible to identify which training errors were related to running related injuries. Still, well supported data on which training errors relate to or cause running related injuries is highly important for determining proper prevention strategies. If methodological limitations in measuring training variables can be resolved, more work can be conducted to define training and the interactions between different training variables, create several hypotheses, test the hypotheses in a large scale prospective study, and explore cause and effect relationships in randomized controlled trials. Level of evidence: 2a PMID:22389869
NASA Astrophysics Data System (ADS)
Iwema, J.; Rosolem, R.; Baatz, R.; Wagener, T.; Bogena, H. R.
2015-07-01
The Cosmic-Ray Neutron Sensor (CRNS) can provide soil moisture information at scales relevant to hydrometeorological modelling applications. Site-specific calibration is needed to translate CRNS neutron intensities into sensor footprint average soil moisture contents. We investigated temporal sampling strategies for calibration of three CRNS parameterisations (modified N0, HMF, and COSMIC) by assessing the effects of the number of sampling days and soil wetness conditions on the performance of the calibration results while investigating actual neutron intensity measurements, for three sites with distinct climate and land use: a semi-arid site, a temperate grassland, and a temperate forest. When calibrated with 1 year of data, both COSMIC and the modified N0 method performed better than HMF. The performance of COSMIC was remarkably good at the semi-arid site in the USA, while the N0mod performed best at the two temperate sites in Germany. The successful performance of COSMIC at all three sites can be attributed to the benefits of explicitly resolving individual soil layers (which is not accounted for in the other two parameterisations). To better calibrate these parameterisations, we recommend in situ soil sampled to be collected on more than a single day. However, little improvement is observed for sampling on more than 6 days. At the semi-arid site, the N0mod method was calibrated better under site-specific average wetness conditions, whereas HMF and COSMIC were calibrated better under drier conditions. Average soil wetness condition gave better calibration results at the two humid sites. The calibration results for the HMF method were better when calibrated with combinations of days with similar soil wetness conditions, opposed to N0mod and COSMIC, which profited from using days with distinct wetness conditions. Errors in actual neutron intensities were translated to average errors specifically to each site. At the semi-arid site, these errors were below the typical measurement uncertainties from in situ point-scale sensors and satellite remote sensing products. Nevertheless, at the two humid sites, reduction in uncertainty with increasing sampling days only reached typical errors associated with satellite remote sensing products. The outcomes of this study can be used by researchers as a CRNS calibration strategy guideline.
Optimum projection pattern generation for grey-level coded structured light illumination systems
NASA Astrophysics Data System (ADS)
Porras-Aguilar, Rosario; Falaggis, Konstantinos; Ramos-Garcia, Ruben
2017-04-01
Structured light illumination (SLI) systems are well-established optical inspection techniques for noncontact 3D surface measurements. A common technique is multi-frequency sinusoidal SLI that obtains the phase map at various fringe periods in order to estimate the absolute phase, and hence, the 3D surface information. Nevertheless, multi-frequency SLI systems employ multiple measurement planes (e.g. four phase shifted frames) to obtain the phase at a given fringe period. It is therefore an age old challenge to obtain the absolute surface information using fewer measurement frames. Grey level (GL) coding techniques have been developed as an attempt to reduce the number of planes needed, because a spatio-temporal GL sequence employing p discrete grey-levels and m frames has the potential to unwrap up to pm fringes. Nevertheless, one major disadvantage of GL based SLI techniques is that there are often errors near the border of each stripe, because an ideal stepwise intensity change cannot be measured. If the step-change in intensity is a single discrete grey-level unit, this problem can usually be overcome by applying an appropriate threshold. However, severe errors occur if the intensity change at the border of the stripe exceeds several discrete grey-level units. In this work, an optimum GL based technique is presented that generates a series of projection patterns with a minimal gradient in the intensity. It is shown that when using this technique, the errors near the border of the stripes can be significantly reduced. This improvement is achieved with the choice generated patterns, and does not involve additional hardware or special post-processing techniques. The performance of that method is validated using both simulations and experiments. The reported technique is generic, works with an arbitrary number of frames, and can employ an arbitrary number of grey-levels.
NASA Astrophysics Data System (ADS)
Sandri, P.
2017-12-01
The paper describes the alignment technique developed for the wavefront error measurement of ellipsoidal mirrors presenting a central hole. The achievement of a good alignment with a classic setup at the finite conjugates when mirrors are uncoated cannot be based on the identification and materialization at naked eye of the retro-reflected spot by the mirror under test as the intensity of the retro-reflected spot results to be ≈1E-3 of the intensity of the injected laser beam of the interferometer. We present the technique developed for the achievement of an accurate alignment in the setup at the finite conjugate even in condition of low intensity based on the use of an autocollimator adjustable in focus position and a small polished flat surface on the rear side of the mirror. The technique for the alignment has successfully been used for the optical test of the concave ellipsoidal mirrors of the METIS coronagraph of the ESA Solar Orbiter mission. The presented method results to be advantageous in terms of precision and of time saving also when the mirrors are reflective coated and integrated into their mechanical hardware.
A probabilistic tornado wind hazard model for the continental United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hossain, Q; Kimball, J; Mensing, R
A probabilistic tornado wind hazard model for the continental United States (CONUS) is described. The model incorporates both aleatory (random) and epistemic uncertainties associated with quantifying the tornado wind hazard parameters. The temporal occurrences of tornadoes within the continental United States (CONUS) is assumed to be a Poisson process. A spatial distribution of tornado touchdown locations is developed empirically based on the observed historical events within the CONUS. The hazard model is an aerial probability model that takes into consideration the size and orientation of the facility, the length and width of the tornado damage area (idealized as a rectanglemore » and dependent on the tornado intensity scale), wind speed variation within the damage area, tornado intensity classification errors (i.e.,errors in assigning a Fujita intensity scale based on surveyed damage), and the tornado path direction. Epistemic uncertainties in describing the distributions of the aleatory variables are accounted for by using more than one distribution model to describe aleatory variations. The epistemic uncertainties are based on inputs from a panel of experts. A computer program, TORNADO, has been developed incorporating this model; features of this program are also presented.« less
Design optimization of ultra-precise elliptical mirrors for hard x-ray nanofocusing at Nanoscopium
NASA Astrophysics Data System (ADS)
Kewish, Cameron M.; Polack, François; Signorato, Riccardo; Somogyi, Andrea
2013-09-01
The design and implementation of a pair of 100 mm-long grazing-incidence total-reflection mirrors for the hard X-ray beamline Nanoscopium at Synchrotron Soleil is presented. A vertically and horizontally nanofocusing mirror pair, oriented in Kirkpatrick-Baez geometry, has been designed and fabricated with the aim of creating a diffraction-limited high-intensity 5 - 20 keV beam with a focal spot size as small as 50 nm. We describe the design considerations, including wave-optical calculations of figures-of-merit that are relevant for spectromicroscopy, such as the focal spot size, depth of field and integrated intensity. The mechanical positioning tolerance in the pitch angle that is required to avoid introducing high-intensity features in the neighborhood of the focal spot is demonstrated with simulations to be of the order of microradians, becoming tighter for shorter focal lengths and therefore directly affecting all nanoprobe mirror systems. Metrology results for the completed mirrors are presented, showing that better than 1.5 °A-rms figure error has been achieved over the full mirror lengths with respect to the designed elliptical surfaces, with less than 60 nrad-rms slope errors.
Effect of signal intensity and camera quantization on laser speckle contrast analysis
Song, Lipei; Elson, Daniel S.
2012-01-01
Laser speckle contrast analysis (LASCA) is limited to being a qualitative method for the measurement of blood flow and tissue perfusion as it is sensitive to the measurement configuration. The signal intensity is one of the parameters that can affect the contrast values due to the quantization of the signals by the camera and analog-to-digital converter (ADC). In this paper we deduce the theoretical relationship between signal intensity and contrast values based on the probability density function (PDF) of the speckle pattern and simplify it to a rational function. A simple method to correct this contrast error is suggested. The experimental results demonstrate that this relationship can effectively compensate the bias in contrast values induced by the quantized signal intensity and correct for bias induced by signal intensity variations across the field of view. PMID:23304650
NASA Astrophysics Data System (ADS)
Li, Xin; Zhou, Shihong; Ma, Jing; Tan, Liying; Shen, Tao
2013-08-01
CMOS is a good candidate tracking detector for satellite optical communications systems with outstanding feature of sub-window for the development of APS (Active Pixel Sensor) technology. For inter-satellite optical communications it is critical to estimate the direction of incident laser beam precisely by measuring the centroid position of incident beam spot. The presence of detector noise results in measurement error, which degrades the tracking performance of systems. In this research, the measurement error of CMOS is derived taking consideration of detector noise. It is shown that the measurement error depends on pixel noise, size of the tracking sub-window (pixels number), intensity of incident laser beam, relative size of beam spot. The influences of these factors are analyzed by numerical simulation. We hope the results obtained in this research will be helpful in the design of CMOS detector satellite optical communications systems.
Voxel-based statistical analysis of uncertainties associated with deformable image registration
NASA Astrophysics Data System (ADS)
Li, Shunshan; Glide-Hurst, Carri; Lu, Mei; Kim, Jinkoo; Wen, Ning; Adams, Jeffrey N.; Gordon, James; Chetty, Indrin J.; Zhong, Hualiang
2013-09-01
Deformable image registration (DIR) algorithms have inherent uncertainties in their displacement vector fields (DVFs).The purpose of this study is to develop an optimal metric to estimate DIR uncertainties. Six computational phantoms have been developed from the CT images of lung cancer patients using a finite element method (FEM). The FEM generated DVFs were used as a standard for registrations performed on each of these phantoms. A mechanics-based metric, unbalanced energy (UE), was developed to evaluate these registration DVFs. The potential correlation between UE and DIR errors was explored using multivariate analysis, and the results were validated by landmark approach and compared with two other error metrics: DVF inverse consistency (IC) and image intensity difference (ID). Landmark-based validation was performed using the POPI-model. The results show that the Pearson correlation coefficient between UE and DIR error is rUE-error = 0.50. This is higher than rIC-error = 0.29 for IC and DIR error and rID-error = 0.37 for ID and DIR error. The Pearson correlation coefficient between UE and the product of the DIR displacements and errors is rUE-error × DVF = 0.62 for the six patients and rUE-error × DVF = 0.73 for the POPI-model data. It has been demonstrated that UE has a strong correlation with DIR errors, and the UE metric outperforms the IC and ID metrics in estimating DIR uncertainties. The quantified UE metric can be a useful tool for adaptive treatment strategies, including probability-based adaptive treatment planning.
Uwingabiye, Jean; Moustanfii, Wafaa; Chadli, Meryem; Sekhsokh, Yassine
2015-01-01
Introduction L'objectif de notre travail était évaluer la contamination microbienne des téléphones mobiles utilisés par les personnels soignants des différents services de l'hôpital militaire d'instructions Mohammed V de Rabat et la comparer à celui d'une population témoin et aussi démontrer l'efficacité des solutions hydroalcoolique dans la désinfection de ces téléphones mobiles. Méthodes Il s'agit d'une étude descriptive transversale réalisée sur une période de 9 mois entre septembre 2010 et juin 2011, dans le service de bactériologie de l'hôpital militaire d'Instruction Mohammed V. Résultats L’étude bactériologique a été faite sur 240 téléphones mobiles dont 50% provenaient de personnels de sante. Le taux de contamination bactérienne de tous les téléphones mobiles était de 100%. Les cultures des bactéries isolées au niveau des téléphones mobiles du personnel médical étaient plus polymorphes que celles de la population témoin (p=0,028). Parmi 437 bactéries isolées: 223(51%) provenaient de téléphones de personnels de santé et 214(49%) de téléphones de la population témoin avec une différence qui n’était pas statistiquement significative(p>0,05) sauf pour les isolats de Staphylocoque à coagulase négative et Staphylococcus aureus. Les bactéries isolées étaient représentées par: Staphylocoque à coagulase (57,7%), Staphylococcus aureus (18,1%), Corynebacterium sp (18,8%), Bacillus sp (2,3%) et autres (2,2%). La différence entre la prévalence des bactéries isolées selon les services et les fonctions des personnels de santé n’était pas statistiquement significative (p>0,05). La désinfection des téléphones portables par la solution hydroalcoolique a réduit à 99,5% le nombre des colonies. Conclusion Ce travail montre que les téléphones portables pourraient jouer un rôle dans la transmission des infections nosocomiales et communautaires. Dans le cadre de prévention de ces risques, il faut sensibiliser les utilisateurs des téléphones mobiles l'importance du lavage des mains et l'utilisation des solutions hydro alcoolique pour désinfecter aussi bien les téléphones portables que les mains. PMID:26977234
NASA Astrophysics Data System (ADS)
Colli, M.; Lanza, L. G.; La Barbera, P.; Chan, P. W.
2014-07-01
The contribution of any single uncertainty factor in the resulting performance of infield rain gauge measurements still has to be comprehensively assessed due to the high number of real world error sources involved, such as the intrinsic variability of rainfall intensity (RI), wind effects, wetting losses, the ambient temperature, etc. In recent years the World Meteorological Organization (WMO) addressed these issues by fostering dedicated investigations, which revealed further difficulties in assessing the actual reference rainfall intensity in the field. This work reports on an extensive assessment of the OTT Pluvio2 weighing gauge accuracy when measuring rainfall intensity under laboratory dynamic conditions (time varying reference flow rates). The results obtained from the weighing rain gauge (WG) were also compared with a MTX tipping-bucket rain gauge (TBR) under the same test conditions. Tests were carried out by simulating various artificial precipitation events, with unsteady rainfall intensity, using a suitable dynamic rainfall generator. Real world rainfall data measured by an Ogawa catching-type drop counter at a field test site located within the Hong Kong International Airport (HKIA) were used as a reference for the artificial rain generation system. Results demonstrate that the differences observed between the laboratory and field performance of catching-type gauges are only partially attributable to the weather and operational conditions in the field. The dynamics of real world precipitation events is responsible for a large part of the measurement errors, which can be accurately assessed in the laboratory under controlled environmental conditions. This allows for new testing methodologies and the development of instruments with enhanced performance in the field.
Settle, Margaret Doyle; Coakley, Amanda Bulette; Annese, Christine Donahue
2017-02-01
Human milk provides superior nutritional value for infants in the neonatal intensive care unit and is the enteral feeding of choice. Our hospital used the system engineering initiative for patient safety model to evaluate the human milk management system in our neonatal intensive care unit. Nurses described the previous process in a negative way, fraught with opportunities for error, increased stress for nurses, and the need to be away from the bedside and their patients. The redesigned process improved the quality and safety of human milk management and created time for the nurses to spend with their patients.
Infrared line intensity measurements in the v = 0-1 band of the ClO radical
NASA Technical Reports Server (NTRS)
Burkholder, James B.; Howard, Carleton J.; Hammer, Philip D.; Goldman, Aaron
1989-01-01
Integrated line intensity measurements in the ClO-radical fundamental vibrational v = 0-1 band were carried out using a high-resolution Fourier transform spectrometer coupled to a long-path-length absorption cell. The results of a series of measurements designed to minimize systematic errors, yielded a value of the fundamental IR band intensity of the ClO-radical equal to 9.68 + or - 1.45/sq cm per atm at 296 K. This result is consistent with all the earlier published results, with the exception of measurements reported by Kostiuk et al. (1986) and Lang et al. (1988).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Junjie; Jia, Hongzhi, E-mail: hzjia@usst.edu.cn
2015-11-15
We propose error analysis using a rotating coordinate system with three parameters of linearly polarized light—incidence angle, azimuth angle on the front surface, and angle between the incidence and vibration planes—and demonstrate the method on a rotating birefringent prism system. The transmittance and angles are calculated plane-by-plane using a birefringence ellipsoid model and the final transmitted intensity equation is deduced. The effects of oblique incidence, light interference, beam convergence, and misalignment of the rotation and prism axes are discussed. We simulate the entire error model using MATLAB and conduct experiments based on a built polarimeter. The simulation and experimental resultsmore » are consistent and demonstrate the rationality and validity of this method.« less
Use of graph theory measures to identify errors in record linkage.
Randall, Sean M; Boyd, James H; Ferrante, Anna M; Bauer, Jacqueline K; Semmens, James B
2014-07-01
Ensuring high linkage quality is important in many record linkage applications. Current methods for ensuring quality are manual and resource intensive. This paper seeks to determine the effectiveness of graph theory techniques in identifying record linkage errors. A range of graph theory techniques was applied to two linked datasets, with known truth sets. The ability of graph theory techniques to identify groups containing errors was compared to a widely used threshold setting technique. This methodology shows promise; however, further investigations into graph theory techniques are required. The development of more efficient and effective methods of improving linkage quality will result in higher quality datasets that can be delivered to researchers in shorter timeframes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
The Treatment of Capital Costs in Educational Projects
ERIC Educational Resources Information Center
Bezeau, Lawrence
1975-01-01
Failure to account for the cost and depreciation of capital leads to suboptimal investments in education, specifically to excessively capital intensive instructional technologies. This type of error, which is particularly serious when planning for developing countries, can be easily avoided. (Author)
WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kearney, V; Gu, X; Chen, S
2014-06-15
Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints inmore » the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.« less
NASA Technical Reports Server (NTRS)
Carpenter, Paul; Armstrong, John
2004-01-01
Improvement in the accuracy of electron-probe microanalysis (EPMA) has been accomplished by critical assessment of standards, correction algorithms, and mass absorption coefficient data sets. Experimental measurement of relative x-ray intensities at multiple accelerating potential highlights errors in the absorption coefficient. The factor method has been applied to the evaluation of systematic errors in the analysis of semiconductor and silicate minds. Accurate EPMA of Martian soil stimulant is necessary in studies that build on Martian rover data in anticipation of missions to Mars.
A Bayesian approach to parameter and reliability estimation in the Poisson distribution.
NASA Technical Reports Server (NTRS)
Canavos, G. C.
1972-01-01
For life testing procedures, a Bayesian analysis is developed with respect to a random intensity parameter in the Poisson distribution. Bayes estimators are derived for the Poisson parameter and the reliability function based on uniform and gamma prior distributions of that parameter. A Monte Carlo procedure is implemented to make possible an empirical mean-squared error comparison between Bayes and existing minimum variance unbiased, as well as maximum likelihood, estimators. As expected, the Bayes estimators have mean-squared errors that are appreciably smaller than those of the other two.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aguilo Valentin, Miguel Alejandro
2016-07-01
This study presents a new nonlinear programming formulation for the solution of inverse problems. First, a general inverse problem formulation based on the compliance error functional is presented. The proposed error functional enables the computation of the Lagrange multipliers, and thus the first order derivative information, at the expense of just one model evaluation. Therefore, the calculation of the Lagrange multipliers does not require the solution of the computationally intensive adjoint problem. This leads to significant speedups for large-scale, gradient-based inverse problems.
Using a Context-aware Medical Application to Address Information Needs for Extubation Decisions
Zhu, Xinxin; Lord, William
2005-01-01
Information overload has been one of the causes of preventable medical errors [1] and escalating costs [2]. A context-aware application with embedded clinical knowledge is proposed to provide practitioners with the appropriate amount of information and content. We developed a prototype of a context-aware medical application to address clinicians’ information needs that arise in a data-intensive unit, the Cardio-Thoracic Intensive Care Unit (CTICU). A major clinical decision supported by the prototype, the extubation decision, is illustrated. PMID:16779455
Experimental compliance calibration of the compact fracture toughness specimen
NASA Technical Reports Server (NTRS)
Fisher, D. M.; Buzzard, R. J.
1980-01-01
Compliances and stress intensity coefficients were determined over crack length to width ratios from 0.1 to 0.8. Displacements were measured at the load points, load line, and crack mouth. Special fixturing was devised to permit accurate measurement of load point displacement. The results are in agreement with the currently used results of boundary collocation analyses. The errors which occur in stress intensity coefficients or specimen energy input determinations made from load line displacement measurements rather than from load point measurements are emphasized.
Grant, Mary Jo C; Larsen, Gitte Y
2007-01-01
Adverse event reporting is a key element for improving patient safety. This study describes a new voluntary, anonymous reporting system that facilitates reporting of near-miss and patient harm events and an assessment of patient harm by the bedside care provider in a pediatric intensive care unit. The results demonstrated the effectiveness of the Patient Safety Report as a method to capture near-miss and patient harm events.
World maps of predicted electron intensities for the ITOS-A/NOAA-1 spacecraft
NASA Technical Reports Server (NTRS)
Stassinopoulos, E. G.
1972-01-01
Maps of electron fluxes 10,000, 1 million, and 10 million particles/sq cm/sec are presented for an ITOS-A/NOAA-1 circular orbit, inclination of 79 deg, and altitude of 1463 km. The uncertainty in the flux values is about a factor of 3, and the error in contour plotting may be plus or minus 2 deg in latitude and plus or minus 3 deg in longitude. The fractional lifetime spent within the different intensity regions is graphed.
Backus Effect on a Perpendicular Errors in Harmonic Models of Real vs. Synthetic Data
NASA Technical Reports Server (NTRS)
Voorhies, C. V.; Santana, J.; Sabaka, T.
1999-01-01
Measurements of geomagnetic scalar intensity on a thin spherical shell alone are not enough to separate internal from external source fields; moreover, such scalar data are not enough for accurate modeling of the vector field from internal sources because of unmodeled fields and small data errors. Spherical harmonic models of the geomagnetic potential fitted to scalar data alone therefore suffer from well-understood Backus effect and perpendicular errors. Curiously, errors in some models of simulated 'data' are very much less than those in models of real data. We analyze select Magsat vector and scalar measurements separately to illustrate Backus effect and perpendicular errors in models of real scalar data. By using a model to synthesize 'data' at the observation points, and by adding various types of 'noise', we illustrate such errors in models of synthetic 'data'. Perpendicular errors prove quite sensitive to the maximum degree in the spherical harmonic expansion of the potential field model fitted to the scalar data. Small errors in models of synthetic 'data' are found to be an artifact of matched truncation levels. For example, consider scalar synthetic 'data' computed from a degree 14 model. A degree 14 model fitted to such synthetic 'data' yields negligible error, but amplifies 4 nT (rmss) added noise into a 60 nT error (rmss); however, a degree 12 model fitted to the noisy 'data' suffers a 492 nT error (rmms through degree 12). Geomagnetic measurements remain unaware of model truncation, so the small errors indicated by some simulations cannot be realized in practice. Errors in models fitted to scalar data alone approach 1000 nT (rmss) and several thousand nT (maximum).
Verbist, Bie; Clement, Lieven; Reumers, Joke; Thys, Kim; Vapirev, Alexander; Talloen, Willem; Wetzels, Yves; Meys, Joris; Aerssens, Jeroen; Bijnens, Luc; Thas, Olivier
2015-02-22
Deep-sequencing allows for an in-depth characterization of sequence variation in complex populations. However, technology associated errors may impede a powerful assessment of low-frequency mutations. Fortunately, base calls are complemented with quality scores which are derived from a quadruplet of intensities, one channel for each nucleotide type for Illumina sequencing. The highest intensity of the four channels determines the base that is called. Mismatch bases can often be corrected by the second best base, i.e. the base with the second highest intensity in the quadruplet. A virus variant model-based clustering method, ViVaMBC, is presented that explores quality scores and second best base calls for identifying and quantifying viral variants. ViVaMBC is optimized to call variants at the codon level (nucleotide triplets) which enables immediate biological interpretation of the variants with respect to their antiviral drug responses. Using mixtures of HCV plasmids we show that our method accurately estimates frequencies down to 0.5%. The estimates are unbiased when average coverages of 25,000 are reached. A comparison with the SNP-callers V-Phaser2, ShoRAH, and LoFreq shows that ViVaMBC has a superb sensitivity and specificity for variants with frequencies above 0.4%. Unlike the competitors, ViVaMBC reports a higher number of false-positive findings with frequencies below 0.4% which might partially originate from picking up artificial variants introduced by errors in the sample and library preparation step. ViVaMBC is the first method to call viral variants directly at the codon level. The strength of the approach lies in modeling the error probabilities based on the quality scores. Although the use of second best base calls appeared very promising in our data exploration phase, their utility was limited. They provided a slight increase in sensitivity, which however does not warrant the additional computational cost of running the offline base caller. Apparently a lot of information is already contained in the quality scores enabling the model based clustering procedure to adjust the majority of the sequencing errors. Overall the sensitivity of ViVaMBC is such that technical constraints like PCR errors start to form the bottleneck for low frequency variant detection.
1984-03-07
GLOcAL CLIMATOLOY 4PANCH uoAFETAC CEILING VERSUS VISIBILITY AIP WEATHER SERVIC[/PAC 6 ! .0ODB8RI)E RAF UK _"_-_ " ___ .-8’ PERCENTAGE FREQUENCY OF...OSIVATIONWS A USAF ETAC 0. . -14.5(OL A) owvo I wv s op wpwm i -- GLOCAL CLIMATOLOGY RRANCH AT CEILING VERSUS VISIBILITYA’.P WEATHr SERVICE/MAC 7 .951
Implications of Psychiatric Comorbidity Among Combat Veterans
2013-10-01
disorders , psychotic disorders , anxiety disorders , personality disorders , and "other" mental disorders (including, but not limited to, eating and sleep...of diagnoses spread across major diagnostic catego- ries. For example, participants with both an anxiety and personality disorder diagnosis were...other disorders (« = 751, 30,3%), and mood and personality disorders (n = 687, 27,7%). Pearson chi-square tests were used to compare the observed
Database Changes (Post-Publication). ERIC Processing Manual, Section X.
ERIC Educational Resources Information Center
Brandhorst, Ted, Ed.
The purpose of this section is to specify the procedure for making changes to the ERIC database after the data involved have been announced in the abstract journals RIE or CIJE. As a matter of general ERIC policy, a document or journal article is not re-announced or re-entered into the database as a new accession for the purpose of accomplishing a…
1980-09-01
de.tona1Uted1 over a mass;ive Kayenta sandstone formation. Thes- e.ventsl- provi ic data for checking, the calculations for motion in :1 s;trong1...53 ~ l Z Kayenta ;andst-ne depOsit similar to thit, of CUNSf 1. The thickness of the soil was v,ried from 0 to 6 ft. Measurements of vertical and
Nanotip Carpets as Antireflection Surfaces
NASA Technical Reports Server (NTRS)
Bae, Youngsam; Mobasser, Sohrab; Manohara, Harish; Lee, Choonsup
2008-01-01
Carpet-like random arrays of metal-coated silicon nanotips have been shown to be effective as antireflection surfaces. Now undergoing development for incorporation into Sun sensors that would provide guidance for robotic exploratory vehicles on Mars, nanotip carpets of this type could also have many uses on Earth as antireflection surfaces in instruments that handle or detect ultraviolet, visible, or infrared light. In the original Sun-sensor application, what is required is an array of 50-micron-diameter apertures on what is otherwise an opaque, minimally reflective surface, as needed to implement a miniature multiple-pinhole camera. The process for fabrication of an antireflection nanotip carpet for this application (see Figure 1) includes, and goes somewhat beyond, the process described in A New Process for Fabricating Random Silicon Nanotips (NPO-40123), NASA Tech Briefs, Vol. 28, No. 1 (November 2004), page 62. In the first step, which is not part of the previously reported process, photolithography is performed to deposit etch masks to define the 50-micron apertures on a silicon substrate. In the second step, which is part of the previously reported process, the non-masked silicon area between the apertures is subjected to reactive ion etching (RIE) under a special combination of conditions that results in the growth of fluorine-based compounds in randomly distributed formations, known in the art as "polymer RIE grass," that have dimensions of the order of microns. The polymer RIE grass formations serve as microscopic etch masks during the next step, in which deep reactive ion etching (DRIE) is performed. What remains after DRIE is the carpet of nano - tips, which are high-aspect-ratio peaks, the tips of which have radii of the order of nanometers. Next, the nanotip array is evaporatively coated with Cr/Au to enhance the absorption of light (more specifically, infrared light in the Sun-sensor application). The photoresist etch masks protecting the apertures are then removed by dipping the substrate into acetone. Finally, for the Sun-sensor application, the back surface of the substrate is coated with a 57-nm-thick layer of Cr for attenuation of sunlight.
Taoufiq, Nezha; Naim, Asmaa; Bouchbika, Zineb; Benchekroune, Nadia; Jouhadi, Hassan; Sahraoui, Souha; Benider, Abdelatif
2017-01-01
Les Tumeurs Stromales Gastro-intestinales « GIST » sont une forme très rare de cancers du tube digestif appartenant à la famille des sarcomes. Le but de ce travail est d'établir le profil épidémiologique et évolutif ainsi que les difficultés diagnostique et thérapeutique de cette pathologie maligne prise en charge dans un pays en développement. Une Etude rétrospective étalée sur 8 ans de Janvier 2002 à Mars 2010, a été mené au Service de Radiothérapie et d'Oncologie du CHU de Casablanca (Maroc) ayant colligée 54 cas de tumeurs stromales gastro-intestinales. L'âge moyen de nos patients était de 55 ans. Le délai moyen d'évolution était de 11 mois (0-72 mois). La biopsie a permis de confirmer le diagnostic dans 14 cas et la chirurgie dans 40 cas. La principale forme histologique était fusiforme (92,6%). Les GIST dans notre série avaient une taille tumorale moyenne de 12,5 cm avec un C-Kit positif dans 52 cas. Le risque évolutif a pu être établi dans 47 cas dont 39 avaient un risque élevé. La chirurgie était le principal traitement des patients de notre sérieAprès un recul moyen de 31 mois, la moitié des patients évaluables de notre série (n=19) est en rémission complète maintenue, le tiers (n=13) est décédé alors que le quart (n=8) présente une récidive locale et /ou métastatique. Quoique les recommandations soient éditées pour la prise en charge de ces tumeurs, ces dernières soulèvent encore de nombreux problèmes aussi bien diagnostiques que thérapeutiques dans notre contexte. PMID:28904693
NASA Astrophysics Data System (ADS)
Wuensche, C. A.; Gavioli, E.; Oliveira, A. L. P. R. S.; da Silva, C.; Cardoso, H. P.; Estácio, S.
2003-08-01
O projeto Educação em Ciências com Observatórios Virtuais foi concebido pelo Instituto Astronômico e Geofísico da USP, agregando diversas instituições de ensino e pesquisa no país para desenvolver competências diversas na educação fundamental, média e superior utilizando a astronomia como ferramenta multidisciplinar. Este trabalho descreve a participação da MOPPE, escola-piloto do INPE no projeto, no período de 2000-2003. Serão apresentadas 1) a criação de um clube de ciências (1999 a 2001) cujo tema foi a colonização de Marte e 2) a ementa de astronomia trabalhada com as 7a. e 8a. séries do ensino fundamental. A proposta do projeto Colonizando Marte foi estudar diversos aspectos de uma missão interplanetária e construir experiementos que permitissem quantificar esses aspectos. Os resultados obtidos incluiram apresentações nas SBPC Jovem em 2000 e 2001. Discutiremos também as ementas de astronomia trabalhadas desde 2001 e o envolvimento dos alunos com atividades ligadas a astronomia, fora da aula de ciências. A inclusão de astronomia no currículo das últimas séries motivou a participação de mais alunos culminando com a conquista de duas medalhas para alunos da 7a. série na Olimpiada Brasileira de Astronomia em 2002. Houve também um aumento no número de participantes na OBA 2003 e nos projetos de astronomia mais elaborados nas Feira de Ciências de 2001 e 2002. Destacamos em 2003 a inclusão da MOPPE no projeto TIE - Telescopes in Education - da NASA, que utiliza o telescópio do Observatório de Mount Wilson (EUA) para observações remotas em projetos pedagógicos para o ensino de astronomia.
Minimisation des inductances propres des condensateurs à film métallisé
NASA Astrophysics Data System (ADS)
Joubert, Ch.; Rojat, G.; Béroual, A.
1995-07-01
In this article, we examine the different factors responsible for the equivalent series inductance in metallized capacitors and we propose structures for capacitors that reduce this inductance. After recalling the structure of metallized capacitors we compare, by experimental measurements, the inductance due to the winding and that one added by the connections. The latter can become preponderant. In order to explain the experimental evolution of the winding impedance vs. frequency, we describe an analytical model which gives the current density in the winding and its impedance. This model enables us to determine the self resonant frequency for different types of capacitors. From where, we can infer the influence of the height of capacitors and their internal and external radius upon performances, It appears that to reduce the equivalent series inductance, it is better to use flat windings and annular windings. Dans cet article nous examinons les différents facteurs responsables de l'inductance équivalente série dans les condensateurs à film métallisé et proposons des géométries de condensateurs qui réduisent cette inductance. Après avoir rappelé la structure des condensateurs à film métallisé, nous comparons, par des mesures expérimentales, l'inductance due au bobinage et l'inductance ajoutée par les connexions. Cette dernière peut devenir prépondérante. Afin d'expliquer l'évolution de l'impédance du bobinage en fonction de la fréquence, nous décrivons un modèle analytique qui donne la densité du courant dans le bobinage et l'impédance de ce dernier. En outre, ce modèle permet de déterminer la fréquence de résonance série de divers types de condensateurs ce qui permet de déduire l'influence de la hauteur des condensateurs et de leurs rayons interne et externe sur les performances. Il apparaît ainsi que, pour diminuer l'inductance équivalente série, il vaut mieux employer des bobinages plats et des bobinages annulaires.
NASA Astrophysics Data System (ADS)
Rodovská, Zuzana; Magna, TomáÅ.¡; Žák, Karel; Kato, Chizu; Savage, Paul S.; Moynier, Frédéric; Skála, Roman; Ježek, Josef
2017-10-01
Moldavites are tektites genetically related to the Ries impact structure, located in Central Europe, but the source materials and the processes related to the chemical fractionation of moldavites are not fully constrained. To further understand moldavite genesis, the Cu and Zn abundances and isotope compositions were measured in a suite of tektites from four different substrewn fields (South Bohemia, Moravia, Cheb Basin, Lusatia) and chemically diverse sediments from the surroundings of the Ries impact structure. Moldavites are slightly depleted in Zn ( 10-20%) and distinctly depleted in Cu (>90%) relative to supposed sedimentary precursors. Moreover, the moldavites show a wide range in δ66Zn values between 1.7 and 3.7‰ (relative to JMC 3-0749 Lyon) and δ65Cu values between 1.6 and 12.5‰ (relative to NIST SRM 976) and are thus enriched in heavy isotopes relative to their possible parent sedimentary sources (δ66Zn = -0.07 to +0.64‰; δ65Cu = -0.4 to +0.7‰). In particular, the Cheb Basin moldavites show some of the highest δ65Cu values (up to 12.5‰) ever observed in natural samples. The relative magnitude of isotope fractionation for Cu and Zn seen here is opposite to oxygen-poor environments such as the Moon where Zn is significantly more isotopically fractionated than Cu. One possibility is that monovalent Cu diffuses faster than divalent Zn in the reduced melt and diffusion will not affect the extent of Zn isotope fractionation. These observations imply that the capability of forming a redox environment may aid in volatilizing some elements, accompanied by isotope fractionation, during the impact process. The greater extent of elemental depletion, coupled with isotope fractionation of more refractory Cu relative to Zn, may also hinge on the presence of carbonyl species of transition metals and electromagnetic charge, which could exist in the impact-induced high-velocity jet of vapor and melts.
Prevendo a atividade solar através de redes neurais nebulosas
NASA Astrophysics Data System (ADS)
Martin, V. A. F.; Poppe, P. C. R.
2003-08-01
Atualmente, a integração de redes neurais com técnicas da Matemática Nebulosa (Fuzzy Sets), tem sido usada robustamente para fazer previsões em vários sistemas físicos. Este trabalho representa uma continuidade da contribuição apresentada anteriormente durante a XXVIIa Reunião Anual da SAB, onde exploramos a aplicação de redes neurais para previsões futuras de séries temporais. Para este, enfatizamos o uso da técnica ANFIS (Adaptative Neuro-Fuzzy Inference System), que consiste em uma rede do tipo back-propagation, onde os dados são processados em uma camada intermediária, tendo numa camada de saída, os dados numéricos. Para que a previsão seja feita com sucesso utilizando-se técnicas matemáticas adequadas, é fundamental a existência de uma série razoavelmente longa de modo que a dinâmica contida nesta possa ser melhor extraída pela rede neural. Nesse sentido, foram utilizados novamente os dados históricos das manchas do Sol (1818-2002) afim de verificar o comportamento futuro da atividade solar (Ciclos de Schawbe) a partir da técnica descrita acima. Previsões realizadas para o ciclo anterior (n.22, máximo de 158,5 em julho de 1989), bem como para o atual (n.23, máximo de 153 em setembro de 2000), apontam valores bastante coerentes com os publicados na literatura, levando em consideração, respectivamente, as barras de erros associadas: 166+/-18 e 160+/-14. Para o próximo ciclo de Schawbe (2006-2017), nossa previsão aponta o valor de 172+/-23 como máximo para o primeiro semestre de 2011 (Abril +/- 3 meses). A ANFIS acompanha de maneira satisfatória o movimento das séries estudadas durante o treinamento e durante a verificação (menor dispersão das funções de pertinência), com erro absoluto inferior a 20 por cento.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Kyung Su; Jeon, Seong-Uk; Lee, Chan-Ju
Purpose: To establish and characterize radiation-induced esophagitis (RIE) in vivo and in vitro. Methods and Materials: Fractionated thoracic irradiation at 0, 8, 12, or 15 Gy was given daily for 5 days to Balb/c or C57Bl/6 mice. Changes in body weight gain and daily food intake were assessed. At the end of the study, we removed the esophagus and examined histology by hematoxylin and eosin staining, immune cell infiltration and apoptosis by fluorescence-activated cell sorting, and gene expression changes by quantitative real-time polymerase chain reaction. Het-1A human esophageal epithelial cells were irradiated at 6 Gy, treated with recombinant human growth factors, and examined for genemore » expression changes, apoptosis, proliferation, and signal transduction pathways. Results: We observed that irradiation at 12 Gy or 15 Gy per fraction produced significant reduction in body weight and decreased food intake in Balb/c mice but not as much in C57Bl/6 mice. Further analyses of Balb/c mice irradiated at 12 Gy/fraction revealed attenuated epithelium, inflamed mucosa, and increased numbers of infiltrating CD4+ helper T cells and apoptotic cells. Moreover, we found that expression of tissue inhibitor for metalloproteinase-1, plasminogen activator inhibitor-1, granulocyte macrophage-colony stimulating factor, vascular endothelial growth factor, and stromal-derived factor-1 were increased, whereas epidermal growth factor (EGF) was decreased. Irradiated Het-1A cells similarly showed a significant decrease in expression of EGF and connective tissue growth factor (CTGF). Treatment of EGF but not CTGF partially protected Het-1A cells from radiation-induced apoptosis and revealed phosphorylation of EGFR, AKT, and ERK signaling pathways. Conclusions: We established a mouse model of RIE in Balb/c mice with 12 Gy × 5 fractions, which showed reduced body weight gain, food intake, and histopathologic features similar to those of human esophagitis. Decreased EGF expression in the irradiated esophagus suggests that EGF may be a potential therapeutic intervention strategy to treat RIE.« less
Souza-Oliveira, Ana Carolina; Cunha, Thúlio Marquez; Passos, Liliane Barbosa da Silva; Lopes, Gustavo Camargo; Gomes, Fabiola Alves; Röder, Denise Von Dolinger de Brito
2016-01-01
Ventilator-associated pneumonia is the most prevalent nosocomial infection in intensive care units and is associated with high mortality rates (14-70%). This study evaluated factors influencing mortality of patients with Ventilator-associated pneumonia (VAP), including bacterial resistance, prescription errors, and de-escalation of antibiotic therapy. This retrospective study included 120 cases of Ventilator-associated pneumonia admitted to the adult adult intensive care unit of the Federal University of Uberlândia. The chi-square test was used to compare qualitative variables. Student's t-test was used for quantitative variables and multiple logistic regression analysis to identify independent predictors of mortality. De-escalation of antibiotic therapy and resistant bacteria did not influence mortality. Mortality was 4 times and 3 times higher, respectively, in patients who received an inappropriate antibiotic loading dose and in patients whose antibiotic dose was not adjusted for renal function. Multiple logistic regression analysis revealed the incorrect adjustment for renal function was the only independent factor associated with increased mortality. Prescription errors influenced mortality of patients with Ventilator-associated pneumonia, underscoring the challenge of proper Ventilator-associated pneumonia treatment, which requires continuous reevaluation to ensure that clinical response to therapy meets expectations. Copyright © 2016. Published by Elsevier Editora Ltda.
Combined Henyey-Greenstein and Rayleigh phase function.
Liu, Quanhua; Weng, Fuzhong
2006-10-01
The phase function is an important parameter that affects the distribution of scattered radiation. In Rayleigh scattering, a scatterer is approximated by a dipole, and its phase function is analytically related to the scattering angle. For the Henyey-Greenstein (HG) approximation, the phase function preserves only the correct asymmetry factor (i.e., the first moment), which is essentially important for anisotropic scattering. When the HG function is applied to small particles, it produces a significant error in radiance. In addition, the HG function is applied only for an intensity radiative transfer. We develop a combined HG and Rayleigh (HG-Rayleigh) phase function. The HG phase function plays the role of modulator extending the application of the Rayleigh phase function for small asymmetry scattering. The HG-Rayleigh phase function guarantees the correct asymmetry factor and is valid for a polarization radiative transfer. It approaches the Rayleigh phase function for small particles. Thus the HG-Rayleigh phase function has wider applications for both intensity and polarimetric radiative transfers. For microwave radiative transfer modeling in this study, the largest errors in the brightness temperature calculations for weak asymmetry scattering are generally below 0.02 K by using the HG-Rayleigh phase function. The errors can be much larger, in the 1-3 K range, if the Rayleigh and HG functions are applied separately.
Operational quality control of daily precipitation using spatio-climatological consistency testing
NASA Astrophysics Data System (ADS)
Scherrer, S. C.; Croci-Maspoli, M.; van Geijtenbeek, D.; Naguel, C.; Appenzeller, C.
2010-09-01
Quality control (QC) of meteorological data is of utmost importance for climate related decisions. The search for an effective automated QC of precipitation data has proven difficult and many weather services still use mainly manual inspection of daily precipitation including MeteoSwiss. However, man power limitations force many weather services to move towards less labour intensive and more automated QC with the challenge to keeping data quality high. In the last decade, several approaches have been presented to objectify daily precipitation QC. Here we present a spatio-climatological approach that will be implemented operationally at MeteoSwiss. It combines the information from the event based spatial distribution of everyday's precipitation field and the historical information of the interpolation error using different precipitation intensity intervals. Expert judgement shows that the system is able to detect potential outliers very well (hardly any missed errors) without creating too many false alarms that need human inspection. 50-80% of all flagged values have been classified as real errors by the data editor. This is much better than the roughly 15-20% using standard spatial regression tests. Very helpful in the QC process is the automatic redistribution of accumulated several day sums. Manual inspection in operations can be reduced and the QC of precipitation objectified substantially.
Error in the Sampling Area of an Optical Disdrometer: Consequences in Computing Rain Variables
Fraile, R.; Castro, A.; Fernández-Raga, M.; Palencia, C.; Calvo, A. I.
2013-01-01
The aim of this study is to improve the estimation of the characteristic uncertainties of optic disdrometers in an attempt to calculate the efficient sampling area according to the size of the drop and to study how this influences the computation of other parameters, taking into account that the real sampling area is always smaller than the nominal area. For large raindrops (a little over 6 mm), the effective sampling area may be half the area indicated by the manufacturer. The error committed in the sampling area is propagated to all the variables depending on this surface, such as the rain intensity and the reflectivity factor. Both variables tend to underestimate the real value if the sampling area is not corrected. For example, the rainfall intensity errors may be up to 50% for large drops, those slightly larger than 6 mm. The same occurs with reflectivity values, which may be up to twice the reflectivity calculated using the uncorrected constant sampling area. The Z-R relationships appear to have little dependence on the sampling area, because both variables depend on it the same way. These results were obtained by studying one particular rain event that occurred on April 16, 2006. PMID:23844393
Reconstitution de données climatiques pour l’Algérie du Nord : application des réseaux neuronaux
NASA Astrophysics Data System (ADS)
Bouaoune, Djahida; Dahmani-Megrerouche, Malika
2010-11-01
In the present context of climate change and preservation of biodiversity, the appreciation of the vulnerability of the natural ecosystems and their capacity of adaptation appears among the main preoccupations to the world level (GIEC, 2007). This assessment of the ecosystems requires the availability of climatic data, what is often made difficult by the weak density or even the absence of meteorological stations notably, to the level of the mountains zones. In order to study the climate-vegetation relationship in North Algeria, we use an automatic interpolation method, the neural network method, for the reconstitution of climatic data of the sampled sites, (1035 phytoecological samples), from the existing meteorological network (269 stations). This method is characterized by a great suppleness of non-linearity and by its capacity for reconstituting information from partial and not well-defined indications such as the case of data provided from meteorological networks. In order to reconstitution of climatic data, we use the explicate variables, longitude, latitude and altitude, the variables to explain being the rainfall and temperatures. To define the best approach, the network calibration has been activated on climatic parameters taken globally or solely, for the whole of study zone, and by geographical sector. The results of the interpolation are expressed through a climatic parameter cartography, released automatically by the MapInfo software. The reliability results obtained by this method can be appreciated by elaboration of errors maps comparing to reference data.
Translation fidelity coevolves with longevity.
Ke, Zhonghe; Mallik, Pramit; Johnson, Adam B; Luna, Facundo; Nevo, Eviatar; Zhang, Zhengdong D; Gladyshev, Vadim N; Seluanov, Andrei; Gorbunova, Vera
2017-10-01
Whether errors in protein synthesis play a role in aging has been a subject of intense debate. It has been suggested that rare mistakes in protein synthesis in young organisms may result in errors in the protein synthesis machinery, eventually leading to an increasing cascade of errors as organisms age. Studies that followed generally failed to identify a dramatic increase in translation errors with aging. However, whether translation fidelity plays a role in aging remained an open question. To address this issue, we examined the relationship between translation fidelity and maximum lifespan across 17 rodent species with diverse lifespans. To measure translation fidelity, we utilized sensitive luciferase-based reporter constructs with mutations in an amino acid residue critical to luciferase activity, wherein misincorporation of amino acids at this mutated codon re-activated the luciferase. The frequency of amino acid misincorporation at the first and second codon positions showed strong negative correlation with maximum lifespan. This correlation remained significant after phylogenetic correction, indicating that translation fidelity coevolves with longevity. These results give new life to the role of protein synthesis errors in aging: Although the error rate may not significantly change with age, the basal rate of translation errors is important in defining lifespan across mammals. © 2017 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
An, B.; Wang, Z.-G.; Yang, L.-C.; Li, X.-P.
2017-09-01
Two-ring aromatics, such as naphthalene, are important fluorescent components of kerosene in the planar laser-induced fluorescent (PLIF) technique. Quantifying measurements of kerosene vapor concentrations by PLIF require a prior knowledge of the fluorescence intensity of naphthalene over a wide temperature and oxygen concentration range. To promote the application of PLIF, a semi-empirical formula based on the collision theory and experimental data at the laser wavelength of 266 nm and a pressure of 0.1 MPa is established to predict the fluorescence intensity of naphthalene at different temperatures and oxygen concentrations. This formula takes vibrational states, temperature, and oxygen quenching into account. Verified by published experimental data, the formula can predict the fluorescence intensity of naphthalene with an error less than 9%.
Recommendations to Improve the Accuracy of Estimates of Physical Activity Derived from Self Report
Ainsworth, Barbara E; Caspersen, Carl J; Matthews, Charles E; Mâsse, Louise C; Baranowski, Tom; Zhu, Weimo
2013-01-01
Context Assessment of physical activity using self-report has the potential for measurement error that can lead to incorrect inferences about physical activity behaviors and bias study results. Objective To provide recommendations to improve the accuracy of physical activity derived from self report. Process We provide an overview of presentations and a compilation of perspectives shared by the authors of this paper and workgroup members. Findings We identified a conceptual framework for reducing errors using physical activity self-report questionnaires. The framework identifies six steps to reduce error: (1) identifying the need to measure physical activity, (2) selecting an instrument, (3) collecting data, (4) analyzing data, (5) developing a summary score, and (6) interpreting data. Underlying the first four steps are behavioral parameters of type, intensity, frequency, and duration of physical activities performed, activity domains, and the location where activities are performed. We identified ways to reduce measurement error at each step and made recommendations for practitioners, researchers, and organizational units to reduce error in questionnaire assessment of physical activity. Conclusions Self-report measures of physical activity have a prominent role in research and practice settings. Measurement error can be reduced by applying the framework discussed in this paper. PMID:22287451
Bootstrap Methods: A Very Leisurely Look.
ERIC Educational Resources Information Center
Hinkle, Dennis E.; Winstead, Wayland H.
The Bootstrap method, a computer-intensive statistical method of estimation, is illustrated using a simple and efficient Statistical Analysis System (SAS) routine. The utility of the method for generating unknown parameters, including standard errors for simple statistics, regression coefficients, discriminant function coefficients, and factor…
CME Velocity and Acceleration Error Estimates Using the Bootstrap Method
NASA Technical Reports Server (NTRS)
Michalek, Grzegorz; Gopalswamy, Nat; Yashiro, Seiji
2017-01-01
The bootstrap method is used to determine errors of basic attributes of coronal mass ejections (CMEs) visually identified in images obtained by the Solar and Heliospheric Observatory (SOHO) mission's Large Angle and Spectrometric Coronagraph (LASCO) instruments. The basic parameters of CMEs are stored, among others, in a database known as the SOHO/LASCO CME catalog and are widely employed for many research studies. The basic attributes of CMEs (e.g. velocity and acceleration) are obtained from manually generated height-time plots. The subjective nature of manual measurements introduces random errors that are difficult to quantify. In many studies the impact of such measurement errors is overlooked. In this study we present a new possibility to estimate measurements errors in the basic attributes of CMEs. This approach is a computer-intensive method because it requires repeating the original data analysis procedure several times using replicate datasets. This is also commonly called the bootstrap method in the literature. We show that the bootstrap approach can be used to estimate the errors of the basic attributes of CMEs having moderately large numbers of height-time measurements. The velocity errors are in the vast majority small and depend mostly on the number of height-time points measured for a particular event. In the case of acceleration, the errors are significant, and for more than half of all CMEs, they are larger than the acceleration itself.
Technological Advancements and Error Rates in Radiation Therapy Delivery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Margalit, Danielle N., E-mail: dmargalit@partners.org; Harvard Cancer Consortium and Brigham and Women's Hospital/Dana Farber Cancer Institute, Boston, MA; Chen, Yu-Hui
2011-11-15
Purpose: Technological advances in radiation therapy (RT) delivery have the potential to reduce errors via increased automation and built-in quality assurance (QA) safeguards, yet may also introduce new types of errors. Intensity-modulated RT (IMRT) is an increasingly used technology that is more technically complex than three-dimensional (3D)-conformal RT and conventional RT. We determined the rate of reported errors in RT delivery among IMRT and 3D/conventional RT treatments and characterized the errors associated with the respective techniques to improve existing QA processes. Methods and Materials: All errors in external beam RT delivery were prospectively recorded via a nonpunitive error-reporting system atmore » Brigham and Women's Hospital/Dana Farber Cancer Institute. Errors are defined as any unplanned deviation from the intended RT treatment and are reviewed during monthly departmental quality improvement meetings. We analyzed all reported errors since the routine use of IMRT in our department, from January 2004 to July 2009. Fisher's exact test was used to determine the association between treatment technique (IMRT vs. 3D/conventional) and specific error types. Effect estimates were computed using logistic regression. Results: There were 155 errors in RT delivery among 241,546 fractions (0.06%), and none were clinically significant. IMRT was commonly associated with errors in machine parameters (nine of 19 errors) and data entry and interpretation (six of 19 errors). IMRT was associated with a lower rate of reported errors compared with 3D/conventional RT (0.03% vs. 0.07%, p = 0.001) and specifically fewer accessory errors (odds ratio, 0.11; 95% confidence interval, 0.01-0.78) and setup errors (odds ratio, 0.24; 95% confidence interval, 0.08-0.79). Conclusions: The rate of errors in RT delivery is low. The types of errors differ significantly between IMRT and 3D/conventional RT, suggesting that QA processes must be uniquely adapted for each technique. There was a lower error rate with IMRT compared with 3D/conventional RT, highlighting the need for sustained vigilance against errors common to more traditional treatment techniques.« less