Sample records for intensity ratio method

  1. Quantitative determination of mineral composition by powder x-ray diffraction

    DOEpatents

    Pawloski, G.A.

    1984-08-10

    An external standard intensity ratio method is used for quantitatively determining mineralogic compositions of samples by x-ray diffraction. The method uses ratios of x-ray intensity peaks from a single run. Constants are previously determined for each mineral which is to be quantitatively measured. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of a reference mineral contained in the sample are used to calculate sample composition.

  2. Quantitative determination of mineral composition by powder X-ray diffraction

    DOEpatents

    Pawloski, Gayle A.

    1986-01-01

    An external standard intensity ratio method is used for quantitatively determining mineralogic compositions of samples by x-ray diffraction. The method uses ratios of x-ray intensity peaks from a single run. Constants are previously determined for each mineral which is to be quantitatively measured. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of a reference mineral contained in the sample are used to calculate sample composition.

  3. Extinction-ratio-independent electrical method for measuring chirp parameters of Mach-Zehnder modulators using frequency-shifted heterodyne.

    PubMed

    Zhang, Shangjian; Wang, Heng; Zou, Xinhai; Zhang, Yali; Lu, Rongguo; Liu, Yong

    2015-06-15

    An extinction-ratio-independent electrical method is proposed for measuring chirp parameters of Mach-Zehnder electric-optic intensity modulators based on frequency-shifted optical heterodyne. The method utilizes the electrical spectrum analysis of the heterodyne products between the intensity modulated optical signal and the frequency-shifted optical carrier, and achieves the intrinsic chirp parameters measurement at microwave region with high-frequency resolution and wide-frequency range for the Mach-Zehnder modulator with a finite extinction ratio. Moreover, the proposed method avoids calibrating the responsivity fluctuation of the photodiode in spite of the involved photodetection. Chirp parameters as a function of modulation frequency are experimentally measured and compared to those with the conventional optical spectrum analysis method. Our method enables an extinction-ratio-independent and calibration-free electrical measurement of Mach-Zehnder intensity modulators by using the high-resolution frequency-shifted heterodyne technique.

  4. A Ratio-Analysis Method to the Dynamics of Excited State Proton Transfer: Pyranine in Water and Micelles.

    PubMed

    Sahu, Kalyanasis; Nandi, Nilanjana; Dolai, Suman; Bera, Avisek

    2018-06-05

    Emission spectrum of a fluorophore undergoing excited state proton transfer (ESPT) often exhibits two distinct bands each representing emissions from protonated and deprotonated forms. The relative contribution of the two bands, best represented by an emission intensity ratio (R) (intensity maximum of the protonated band / intensity maximum of the deprotonated band), is an important parameter which usually denotes feasibility or promptness of the ESPT process. However, the use of ratio is only limited to the interpretation of steady-state fluorescence spectra. Here, for the first time, we exploit the time-dependence of the ratio (R(t)), calculated from time-resolved emission spectra (TRES) at different times, to analyze ESPT dynamics. TRES at different times were fitted with a sum of two lognormal-functions representing each peaks and then, the peak intensity ratio, R(t) was calculated and further fitted with an analytical function. Recently, a time-resolved area-normalized emission spectra (TRANES)-based analysis was presented where the decay of protonated emission or the rise of deprotonated emission intensity conveniently accounts for the ESPT dynamics. We show that these two methods are equivalent but the new method provides more insights on the nature of the ESPT process.

  5. Intensity ratio to improve black hole assessment in multiple sclerosis.

    PubMed

    Adusumilli, Gautam; Trinkaus, Kathryn; Sun, Peng; Lancia, Samantha; Viox, Jeffrey D; Wen, Jie; Naismith, Robert T; Cross, Anne H

    2018-01-01

    Improved imaging methods are critical to assess neurodegeneration and remyelination in multiple sclerosis. Chronic hypointensities observed on T1-weighted brain MRI, "persistent black holes," reflect severe focal tissue damage. Present measures consist of determining persistent black holes numbers and volumes, but do not quantitate severity of individual lesions. Develop a method to differentiate black and gray holes and estimate the severity of individual multiple sclerosis lesions using standard magnetic resonance imaging. 38 multiple sclerosis patients contributed images. Intensities of lesions on T1-weighted scans were assessed relative to cerebrospinal fluid intensity using commercial software. Magnetization transfer imaging, diffusion tensor imaging and clinical testing were performed to assess associations with T1w intensity-based measures. Intensity-based assessments of T1w hypointensities were reproducible and achieved > 90% concordance with expert rater determinations of "black" and "gray" holes. Intensity ratio values correlated with magnetization transfer ratios (R = 0.473) and diffusion tensor imaging metrics (R values ranging from 0.283 to -0.531) that have been associated with demyelination and axon loss. Intensity ratio values incorporated into T1w hypointensity volumes correlated with clinical measures of cognition. This method of determining the degree of hypointensity within multiple sclerosis lesions can add information to conventional imaging. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Method for calibrating a Fourier transform ion cyclotron resonance mass spectrometer

    DOEpatents

    Smith, Richard D.; Masselon, Christophe D.; Tolmachev, Aleksey

    2003-08-19

    A method for improving the calibration of a Fourier transform ion cyclotron resonance mass spectrometer wherein the frequency spectrum of a sample has been measured and the frequency (f) and intensity (I) of at least three species having known mass to charge (m/z) ratios and one specie having an unknown (m/z) ratio have been identified. The method uses the known (m/z) ratios, frequencies, and intensities at least three species to calculate coefficients A, B, and C, wherein the mass to charge ratio of a least one of the three species (m/z).sub.i is equal to ##EQU1## wherein f.sub.i is the detected frequency of the specie, G(I.sub.i) is a predetermined function of the intensity of the species, and Q is a predetermined exponent. Using the calculated values for A, B, and C, the mass to charge ratio of the unknown specie (m/z).sub.ii is calculated as the sum of ##EQU2## wherein f.sub.ii is the measured frequency of the unknown specie, and (I.sub.ii) is the measured intensity of the unknown specie.

  7. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    PubMed

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  8. A simple method for determining stress intensity factors for a crack in bi-material interface

    NASA Astrophysics Data System (ADS)

    Morioka, Yuta

    Because of violently oscillating nature of stress and displacement fields near the crack tip, it is difficult to obtain stress intensity factors for a crack between two dis-similar media. For a crack in a homogeneous medium, it is a common practice to find stress intensity factors through strain energy release rates. However, individual strain energy release rates do not exist for bi-material interface crack. Hence it is necessary to find alternative methods to evaluate stress intensity factors. Several methods have been proposed in the past. However they involve mathematical complexity and sometimes require additional finite element analysis. The purpose of this research is to develop a simple method to find stress intensity factors in bi-material interface cracks. A finite element based projection method is proposed in the research. It is shown that the projection method yields very accurate stress intensity factors for a crack in isotropic and anisotropic bi-material interfaces. The projection method is also compared to displacement ratio method and energy method proposed by other authors. Through comparison it is found that projection method is much simpler to apply with its accuracy comparable to that of displacement ratio method.

  9. Image quality enhancement in low-light-level ghost imaging using modified compressive sensing method

    NASA Astrophysics Data System (ADS)

    Shi, Xiaohui; Huang, Xianwei; Nan, Suqin; Li, Hengxing; Bai, Yanfeng; Fu, Xiquan

    2018-04-01

    Detector noise has a significantly negative impact on ghost imaging at low light levels, especially for existing recovery algorithm. Based on the characteristics of the additive detector noise, a method named modified compressive sensing ghost imaging is proposed to reduce the background imposed by the randomly distributed detector noise at signal path. Experimental results show that, with an appropriate choice of threshold value, modified compressive sensing ghost imaging algorithm can dramatically enhance the contrast-to-noise ratio of the object reconstruction significantly compared with traditional ghost imaging and compressive sensing ghost imaging methods. The relationship between the contrast-to-noise ratio of the reconstruction image and the intensity ratio (namely, the average signal intensity to average noise intensity ratio) for the three reconstruction algorithms are also discussed. This noise suppression imaging technique will have great applications in remote-sensing and security areas.

  10. A re-evaluation of finite-element models and stress-intensity factors for surface cracks emanating from stress concentrations

    NASA Technical Reports Server (NTRS)

    Tan, P. W.; Raju, I. S.; Shivakumar, K. N.; Newman, J. C., Jr.

    1988-01-01

    A re-evaluation of the 3-D finite-element models and methods used to analyze surface crack at stress concentrations is presented. Previous finite-element models used by Raju and Newman for surface and corner cracks at holes were shown to have ill-shaped elements at the intersection of the hole and crack boundaries. These ill-shaped elements tended to make the model too stiff and, hence, gave lower stress-intensity factors near the hole-crack intersection than models without these elements. Improved models, without these ill-shaped elements, were developed for a surface crack at a circular hole and at a semi-circular edge notch. Stress-intensity factors were calculated by both the nodal-force and virtual-crack-closure methods. Both methods and different models gave essentially the same results. Comparisons made between the previously developed stress-intensity factor equations and the results from the improved models agreed well except for configurations with large notch-radii-to-plate-thickness ratios. Stress-intensity factors for a semi-elliptical surface crack located at the center of a semi-circular edge notch in a plate subjected to remote tensile loadings were calculated using the improved models. The ratio of crack depth to crack length ranged form 0.4 to 2; the ratio of crack depth to plate thickness ranged from 0.2 to 0.8; and the ratio of notch radius to the plate thickness ranged from 1 to 3. The models had about 15,000 degrees-of-freedom. Stress-intensity factors were calculated by using the nodal-force method.

  11. Identification of Intensity Ratio Break Points from Photon Arrival Trajectories in Ratiometric Single Molecule Spectroscopy

    PubMed Central

    Bingemann, Dieter; Allen, Rachel M.

    2012-01-01

    We describe a statistical method to analyze dual-channel photon arrival trajectories from single molecule spectroscopy model-free to identify break points in the intensity ratio. Photons are binned with a short bin size to calculate the logarithm of the intensity ratio for each bin. Stochastic photon counting noise leads to a near-normal distribution of this logarithm and the standard student t-test is used to find statistically significant changes in this quantity. In stochastic simulations we determine the significance threshold for the t-test’s p-value at a given level of confidence. We test the method’s sensitivity and accuracy indicating that the analysis reliably locates break points with significant changes in the intensity ratio with little or no error in realistic trajectories with large numbers of small change points, while still identifying a large fraction of the frequent break points with small intensity changes. Based on these results we present an approach to estimate confidence intervals for the identified break point locations and recommend a bin size to choose for the analysis. The method proves powerful and reliable in the analysis of simulated and actual data of single molecule reorientation in a glassy matrix. PMID:22837704

  12. Ultrasound hepatic/renal ratio and hepatic attenuation rate for quantifying liver fat content.

    PubMed

    Zhang, Bo; Ding, Fang; Chen, Tian; Xia, Liang-Hua; Qian, Juan; Lv, Guo-Yi

    2014-12-21

    To establish and validate a simple quantitative assessment method for nonalcoholic fatty liver disease (NAFLD) based on a combination of the ultrasound hepatic/renal ratio and hepatic attenuation rate. A total of 170 subjects were enrolled in this study. All subjects were examined by ultrasound and (1)H-magnetic resonance spectroscopy ((1)H-MRS) on the same day. The ultrasound hepatic/renal echo-intensity ratio and ultrasound hepatic echo-intensity attenuation rate were obtained from ordinary ultrasound images using the MATLAB program. Correlation analysis revealed that the ultrasound hepatic/renal ratio and hepatic echo-intensity attenuation rate were significantly correlated with (1)H-MRS liver fat content (ultrasound hepatic/renal ratio: r = 0.952, P = 0.000; hepatic echo-intensity attenuation r = 0.850, P = 0.000). The equation for predicting liver fat content by ultrasound (quantitative ultrasound model) is: liver fat content (%) = 61.519 × ultrasound hepatic/renal ratio + 167.701 × hepatic echo-intensity attenuation rate -26.736. Spearman correlation analysis revealed that the liver fat content ratio of the quantitative ultrasound model was positively correlated with serum alanine aminotransferase, aspartate aminotransferase, and triglyceride, but negatively correlated with high density lipoprotein cholesterol. Receiver operating characteristic curve analysis revealed that the optimal point for diagnosing fatty liver was 9.15% in the quantitative ultrasound model. Furthermore, in the quantitative ultrasound model, fatty liver diagnostic sensitivity and specificity were 94.7% and 100.0%, respectively, showing that the quantitative ultrasound model was better than conventional ultrasound methods or the combined ultrasound hepatic/renal ratio and hepatic echo-intensity attenuation rate. If the (1)H-MRS liver fat content had a value < 15%, the sensitivity and specificity of the ultrasound quantitative model would be 81.4% and 100%, which still shows that using the model is better than the other methods. The quantitative ultrasound model is a simple, low-cost, and sensitive tool that can accurately assess hepatic fat content in clinical practice. It provides an easy and effective parameter for the early diagnosis of mild hepatic steatosis and evaluation of the efficacy of NAFLD treatment.

  13. Stress-intensity factors for small surface and corner cracks in plates

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Atluri, S. N.; Newman, J. C., Jr.

    1988-01-01

    Three-dimensional finite-element and finite-alternating methods were used to obtain the stress-intensity factors for small surface and corner cracked plates subjected to remote tension and bending loads. The crack-depth-to-crack-length ratios (a/c) ranged from 0.2 to 1 and the crack-depth-to-plate-thickness ratios (a/t) ranged from 0.05 to 0.2. The performance of the finite-element alternating method was studied on these crack configurations. A study of the computational effort involved in the finite-element alternating method showed that several crack configurations could be analyzed with a single rectangular mesh idealization, whereas the conventional finite-element method requires a different mesh for each configuration. The stress-intensity factors obtained with the finite-element-alternating method agreed well (within 5 percent) with those calculated from the finite-element method with singularity elements.

  14. Stress-intensity factors for circumferential surface cracks in pipes and rods under tension and bending loads

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Newman, J. C., Jr.

    1985-01-01

    The purpose of this paper is to present stress-intensity factors for a wide range of nearly semi-elliptical surface cracks in pipes and rods. The configurations were subjected to either remote tension or bending loads. For pipes, the ratio of crack depth to crack length (a/c) ranged from 0.6 to 1; the ratio of crack depth to wall thickness (a/t) ranged from 0.2 to 0.8; and the ratio of internal radius to wall thickness (R/t) ranged from 1 to 10. For rods, the ratio of crack depth to crack length also ranged from 0.6 to 1; and the ratio of crack depth to rod diameter (a/D) ranged from 0.05 to 0.35. These particular crack configurations were chosen to cover the range of crack shapes (a/c) that have been observed in experiments conducted on pipes and rods under tension and bending fatigue loads. The stress-intensity factors were calculated by a three-dimensional finite-element method. The finite-element models employed singularity elements along the crack front and linear-strain elements elsewhere. The models had about 6500 degrees of freedom. The stress-intensity factors were evaluated using a nodal-force method.

  15. Valence electronic structure of Ni in Ni Si alloys from relative K X-ray intensity studies

    NASA Astrophysics Data System (ADS)

    Kalayci, Y.; Aydinuraz, A.; Tugluoglu, B.; Mutlu, R. H.

    2007-02-01

    The Kβ-to-Kα X-ray intensity ratio of Ni in Ni 3Si, Ni 2Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni 2Si and then increases from Ni 2Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal alloys.

  16. Calculation of Stress Intensity Factors for Interfacial Cracks in Fiber Metal Laminates

    NASA Technical Reports Server (NTRS)

    Wang, John T.

    2009-01-01

    Stress intensity factors for interfacial cracks in Fiber Metal Laminates (FML) are computed by using the displacement ratio method recently developed by Sun and Qian (1997, Int. J. Solids. Struct. 34, 2595-2609). Various FML configurations with single and multiple delaminations subjected to different loading conditions are investigated. The displacement ratio method requires the total energy release rate, bimaterial parameters, and relative crack surface displacements as input. Details of generating the energy release rates, defining bimaterial parameters with anisotropic elasticity, and selecting proper crack surface locations for obtaining relative crack surface displacements are discussed in the paper. Even though the individual energy release rates are nonconvergent, mesh-size-independent stress intensity factors can be obtained. This study also finds that the selection of reference length can affect the magnitudes and the mode mixity angles of the stress intensity factors; thus, it is important to report the reference length used with the calculated stress intensity factors.

  17. Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods

    NASA Astrophysics Data System (ADS)

    Civale, John; Rivens, Ian; Shaw, Adam; ter Haar, Gail

    2018-03-01

    Characterisation of the spatial peak intensity at the focus of high intensity focused ultrasound transducers is difficult because of the risk of damage to hydrophone sensors at the high focal pressures generated. Hill et al (1994 Ultrasound Med. Biol. 20 259-69) provided a simple equation for estimating spatial-peak intensity for solid spherical bowl transducers using measured acoustic power and focal beamwidth. This paper demonstrates theoretically and experimentally that this expression is only strictly valid for spherical bowl transducers without a central (imaging) aperture. A hole in the centre of the transducer results in over-estimation of the peak intensity. Improved strategies for determining focal peak intensity from a measurement of total acoustic power are proposed. Four methods are compared: (i) a solid spherical bowl approximation (after Hill et al 1994 Ultrasound Med. Biol. 20 259-69), (ii) a numerical method derived from theory, (iii) a method using measured sidelobe to focal peak pressure ratio, and (iv) a method for measuring the focal power fraction (FPF) experimentally. Spatial-peak intensities were estimated for 8 transducers at three drive powers levels: low (approximately 1 W), moderate (~10 W) and high (20-70 W). The calculated intensities were compared with those derived from focal peak pressure measurements made using a calibrated hydrophone. The FPF measurement method was found to provide focal peak intensity estimates that agreed most closely (within 15%) with the hydrophone measurements, followed by the pressure ratio method (within 20%). The numerical method was found to consistently over-estimate focal peak intensity (+40% on average), however, for transducers with a central hole it was more accurate than using the solid bowl assumption (+70% over-estimation). In conclusion, the ability to make use of an automated beam plotting system, and a hydrophone with good spatial resolution, greatly facilitates characterisation of the FPF, and consequently gives improved confidence in estimating spatial peak intensity from measurement of acoustic power.

  18. Molecular transitions as probes of the physical conditions of extragalactic environments

    NASA Astrophysics Data System (ADS)

    Viti, Serena

    2017-11-01

    Aims: We present a method to interpret molecular observations and molecular line ratios in nearby extragalactic regions. Methods: Ab initio grids of time dependent chemical models, varying in gas density, temperature, cosmic ray ionization rate, and radiation field, are used as inputs into RADEX calculations. Tables of abundances, column densities, theoretical line intensities, and line ratios for some of the most used dense gas tracers are provided. The degree of correlation as well as degeneracy inherent in molecular ratios is discussed. Comparisons of the theoretical intensities with example observations are also provided. Results: We find that, within the parameters space explored, chemical abundances can be constrained by a well-defined set of gas density, gas temperature, and cosmic ray ionization rates for the species we investigate here. However, line intensities, and more importantly line ratios, from different chemical models can be very similar, thereby leading to a clear degeneracy. We also find that the gas subjected to a galactic cosmic ray ionization rate will not necessarily have reached steady state in 1 million years. The species most affected by time dependency effects are HCN and CS, which are both high density tracers. We use our ab initio method to fit an example set of data from two galaxies, I.e. M 82 and NGC 253. We find that (I) molecular line ratios can be easily matched even with erroneous individual line intensities; (II) no set of species can be matched by a one-component interstellar medium (ISM); and (III) a species may be a good tracer of an energetic process but only under specific density and temperature conditions. Conclusions: We provide tables of chemical abundances and line intensities ratios for some of the most commonly observed extragalactic tracers of dense gas for a grid of models. We show that by taking the chemistry behind each species and the individual line intensities into consideration, many degeneracies that arise by just using molecular line ratios can be avoided. Finally we show that using a species or a ratio as a tracer of an individual energetic process, such as cosmic rays and UV, ought to be done with caution. Tables 2-11 are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/607/A118

  19. Study on the application of Raman spectroscopy on detecting water hardness.

    PubMed

    Yang, Chang-Hu; Shi, Xiang-Hua; Yuan, Jian-Hui

    2014-05-01

    Laser Raman spectrum method was used to study the hardness index of four water samples. The ratio of bending vibration peak intensity to stretching vibration peak intensity of these water samples was measured. The results showed that as the total hardness of water decreases, so does the ratio. This offers a possible new approach to water quality analysis that is both simple and effective.

  20. Method and apparatus for optical temperature measurements

    DOEpatents

    Angel, S.M.; Hirschfeld, T.B.

    1986-04-22

    A method and apparatus are provided for remotely monitoring temperature. Both method and apparatus employ a temperature probe material having an excitation-dependent emission line whose fluorescence intensity varies directly with temperature whenever excited by light having a first wavelength and whose fluorescence intensity varies inversely with temperature whenever excited by light having a second wavelength. Temperature is measured by alternatively illiminating the temperature probe material with light having the first wavelength and light having the second wavelength, monitoring the intensity of the successive emissions of the excitation-dependent emission line, and relating the intensity ratio of successive emissions to temperature. 3 figs.

  1. Method and apparatus for optical temperature measurements

    DOEpatents

    Angel, S. Michael; Hirschfeld, Tomas B.

    1988-01-01

    A method and apparatus are provided for remotely monitoring temperature. Both method and apparatus employ a temperature probe material having an excitation-dependent emission line whose fluorescence intensity varies directly with temperature whenever excited by light having a first wavelength and whose fluorescence intensity varies inversely with temperature whenever excited by light having a second wavelength. Temperature is measured by alternatively illuminating the temperature probe material with light having the first wavelength and light having the second wavelength, monitoring the intensity of the successive emissions of the excitation-dependent emission line, and relating the intensity ratio of successive emissions to temperature.

  2. Stress intensity and displacement coefficients for radially cracked ring segments subject to three-point bending

    NASA Technical Reports Server (NTRS)

    Gross, B.; Srawley, J. E.

    1983-01-01

    The boudary collocation method was used to generate Mode 1 stress intensity and crack mouth displacement coefficients for internally and externally radially cracked ring segments (arc bend specimens) subjected to three point radial loading. Numerical results were obtained for ring segment outer to inner radius ratios (R sub o/ R sub i) ranging from 1.10 to 2.50 and crack length to width ratios (a/W) ranging from 0.1 to 0.8. Stress intensity and crack mouth displacement coefficients were found to depend on the ratios R sub o/R sub i and a/W as well as the included angle between the directions of the reaction forces.

  3. Three-dimensional finite-element analysis of chevron-notched fracture specimens

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Newman, J. C., Jr.

    1984-01-01

    Stress-intensity factors and load-line displacements were calculated for chevron-notched bar and rod fracture specimens using a three-dimensional finite-element analysis. Both specimens were subjected to simulated wedge loading (either uniform applied displacement or uniform applied load). The chevron-notch sides and crack front were assumed to be straight. Crack-length-to-specimen width ratios (a/w) ranged from 0.4 to 0.7. The width-to-thickness ratio (w/B) was 1.45 or 2. The bar specimens had a height-to-width ratio of 0.435 or 0.5. Finite-element models were composed of singularity elements around the crack front and 8-noded isoparametric elements elsewhere. The models had about 11,000 degrees of freedom. Stress-intensity factors were calculated by using a nodal-force method for distribution along the crack front and by using a compliance method for average values. The stress intensity factors and load-line displacements are presented and compared with experimental solutions from the literature. The stress intensity factors and load-line displacements were about 2.5 and 5 percent lower than the reported experimental values, respectively.

  4. Assessment of Renal Ischemia By Optical Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fitzgerald, J T; Demos, S; Michalopoulou, A

    2004-01-07

    Introduction: No reliable method currently exists for quantifying the degree of warm ischemia in kidney grafts prior to transplantation. We describe a method for evaluating pretransplant warm ischemia time using optical spectroscopic methods. Methods: Lewis rat kidney vascular pedicles were clamped unilaterally in vivo for 0, 5, 10, 20, 30, 60, 90 or 120 minutes; 8 animals were studied at each time point. Injured and contra-lateral control kidneys were then flushed with Euro-Collins solution, resected and placed on ice. 335 nm excitation autofluorescence as well as cross polarized light scattering images were taken of each injured and control kidney usingmore » filters of various wavelengths. The intensity ratio of the injured to normal kidneys was compared to ischemia time. Results: Autofluorescence intensity ratios through a 450 nm filter and light scattering intensity ratios through an 800 nm filter both decreased significantly with increasing ischemia time (p < 0.0001 for each method, one-way ANOVA). All adjacent and non-adjacent time points between 0 and 90 minutes were distinguishable using one of these two modalities by Fisher's PLSD. Conclusions: Optical spectroscopic methods can accurately quantify warm ischemia time in kidneys that have been subsequently hypothermically preserved. Further studies are needed to correlate results with physiological damage and posttransplant performance.« less

  5. Use of generalized population ratios to obtain Fe XV line intensities and linewidths at high electron densities

    NASA Technical Reports Server (NTRS)

    Kastner, S. O.; Bhatia, A. K.

    1980-01-01

    A generalized method for obtaining individual level population ratios is used to obtain relative intensities of extreme ultraviolet Fe XV emission lines in the range 284-500 A, which are density dependent for electron densities in the tokamak regime or higher. Four lines in particular are found to attain quite high intensities in the high-density limit. The same calculation provides inelastic contributions to linewidths. The method connects level populations and level widths through total probabilities t(ij), related to 'taboo' probabilities of Markov chain theory. The t(ij) are here evaluated for a real atomic system, being therefore of potential interest to random-walk theorists who have been limited to idealized systems characterized by simplified transition schemes.

  6. Use of generalized population ratios to obtain Fe XV line intensities and linewidths at high electron densities

    NASA Astrophysics Data System (ADS)

    Kastner, S. O.; Bhatia, A. K.

    1980-08-01

    A generalized method for obtaining individual level population ratios is used to obtain relative intensities of extreme ultraviolet Fe XV emission lines in the range 284-500 A, which are density dependent for electron densities in the tokamak regime or higher. Four lines in particular are found to attain quite high intensities in the high-density limit. The same calculation provides inelastic contributions to linewidths. The method connects level populations and level widths through total probabilities t(ij), related to 'taboo' probabilities of Markov chain theory. The t(ij) are here evaluated for a real atomic system, being therefore of potential interest to random-walk theorists who have been limited to idealized systems characterized by simplified transition schemes.

  7. Improvable method for Halon 1301 concentration measurement based on infrared absorption

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Lu, Song; Guan, Yu

    2015-09-01

    Halon 1301 has attached much interest because of its pervasive use as an effective fire suppressant agent in aircraft related fires, and the study of fire suppressant agent concentration measurement is especially of interest. In this work, a Halon 1301 concentration measurement method based on the Beer-Lambert law is developed. IR light is transmitted through mixed gas, and the light intensity with and without the agent present is measured. The intensity ratio is a function of the volume percentage of Halon 1301, and the voltage output of the detector is proportional to light intensity. As such, the relationship between the volume percentage and voltage ratio can be established. The concentration measurement system shows a relative error of the system less than ±2.50%, and a full scale error within 1.20%. This work also discusses the effect of temperature and relative humidity (RH) on the calibration. The experimental results of voltage ratio versus Halon 1301 volume percentage relationship show that the voltage ratio drops significantly as temperature rises from 25 to 100 °C, and it decreases as RH rises from 0% to 100%.

  8. Accurate thermometry based on the red and green fluorescence intensity ratio in NaYF4: Yb, Er nanocrystals for bioapplication.

    PubMed

    Liu, Lixin; Qin, Feng; Lv, Tianquan; Zhang, Zhiguo; Cao, Wenwu

    2016-10-15

    A biological temperature measurement method based on the fluorescence intensity ratio (FIR) was developed to reduce uncertainty. The upconversion luminescence of NaYF4:Yb, Er nanocrystals was studied as a function of temperature around the physiologically relevant range of 300-330 K. We found that the green-green FIR Fe and red-green FIR (I660/I540) varied linearly as temperature increased. The thermometric uncertainties using the two FIRs were discussed and were determined to be almost constant at 0.6 and 0.09 K for green-green and red-green, respectively. The lower thermometric uncertainty comes from the intense signal-to-noise ratio of the measured FIRs owing to their comparable fluorescence intensities.

  9. Stress-intensity factors and crack-opening displacements for round compact specimens. [fracture toughness of metallic materials

    NASA Technical Reports Server (NTRS)

    Newman, J. C., Jr.

    1979-01-01

    A two dimensional, boundary collocation stress analysis was used to analyze various round compact specimens. The influence of the round external boundary and of pin-loaded holes on stress intensity factors and crack opening displacements was determined as a function of crack-length-to-specimen-width ratios. A wide-range equation for the stress intensity factors was developed. Equations for crack-surface displacements and load-point displacements were also developed. In addition, stress intensity factors were calculated from compliance methods to demonstrate that load-displacement records must be made at the loading points and not along the crack line for crack-length-to-specimen-width ratios less than about 0.4.

  10. Optical thermometry using fluorescence intensities multi-ratios in NaGdTiO4:Yb3+/Tm3+ phosphors

    NASA Astrophysics Data System (ADS)

    Zhou, Aihua; Song, Feng; Song, Feifei; Feng, Ming; Adnan, Khan; Ju, Dandan; Wang, Xueqing

    2018-04-01

    The NaGdTiO4:Yb3+/Tm3+ phosphor has been effectively synthesized by the traditional solid-state reaction method and its down-conversion and up-conversion luminescence properties were systematically studied. The results indicate that the electric dipole-dipole interaction is the main mechanism for the luminescence quenching. The fact that the ratios of the up-conversion intensities, i.e., I795nm/I798nm, I807nm/I798nm, and I812nm/I798nm, increase linearly with temperature (100 K-300 K) provides us a simple and accurate temperature measurement method. Multi-ratios can be more accurate than using only one ratio, allowing for self-referenced temperature determination. It's promising for NaGdTiO4: Yb3+/Tm3+ to be used for optical temperature sensors.

  11. Radio thermal sounding of natural environments

    NASA Astrophysics Data System (ADS)

    Gauss, Martin; Lomukhin, Yuriy

    2017-11-01

    At the moment, methods of sounding a status of soil, plant, forest and aquatic environments using radiometry and radar methods are intensively used. The main source of information using radar sounding is the back reflection ratio. The radiometric method is used for detection of the brightness temperature. In this paper, a communication between the back reflection ratio and the brightness temperature is described. This communication is proportional.

  12. Gap prepulse inhibition of the auditory late response in healthy subjects.

    PubMed

    Ku, Yunseo; Ahn, Joong Woo; Kwon, Chiheon; Suh, Myung-Whan; Lee, Jun Ho; Oh, Seung Ha; Kim, Hee Chan

    2015-11-01

    The gap-startle paradigm has been used as a behavioral method for tinnitus screening in animal studies. This study aimed to investigate gap prepulse inhibition (GPI) of the auditory late response (ALR) as the objective response of the gap-intense sound paradigm in humans. ALRs were recorded in response to gap-intense and no-gap-intense sound stimuli in 27 healthy subjects. The amplitudes of the baseline-to-peak (N1, P2, and N2) and the peak-to-peak (N1P2 and P2N2) were compared between two averaged ALRs. The variations in the inhibition ratios of N1P2 and P2N2 during the experiment were analyzed by increasing stimuli repetitions. The effect of stimulus parameter adjustments on GPI ratios was evaluated. No-gap-intense sound stimuli elicited greater peak amplitudes than gap-intense sound stimuli, and significant differences were found across all peaks. The overall mean inhibition ratios were significantly lower than 1.0, where the value 1.0 indicates that there were no differences between gap-intense and no-gap-intense sound responses. The initial decline in GPI ratios was shown in N1P2 and P2N2 complexes, and this reduction was nearly complete after 100 stimulus repetitions. Significant effects of gap length and interstimulus interval on GPI ratios were observed. We found significant inhibition of ALR peak amplitudes in performing the gap-intense sound paradigm in healthy subjects. The N1P2 complex represented GPI well in terms of suppression degree and test-retest reliability. Our findings offer practical information for the comparative study of healthy subjects and tinnitus patients using the gap-intense sound paradigm with the ALR. © 2015 Society for Psychophysiological Research.

  13. Temperature-controlled down-conversion luminescence behavior of Eu3+ -doped transparent MF2 (M = Ba, Ca, Sr) glass ceramics.

    PubMed

    Zhou, B; E, C Q; Bu, Y Y; Meng, L; Yan, X H; Wang, X F

    2017-03-01

    Eu 3 + -doped transparent glass ceramics containing MF 2 (M = Ba, Ca, Sr) nanocrystals were fabricated using a melt-quenching method, and the resulting structures were studied using X-ray diffraction. Levels 5 D 1 and 5 D 0 of Eu 3 + ions were verified as thermally coupled levels using the fluorescence intensity ratio method. The fluorescence intensity ratios, optical temperature sensitivity and thermal quenching ratios of the transparent glass ceramics were studied as a function of temperature. With an increase in temperature, the relative sensitivity (S R ) decreased sharply at first, then slowly increased, before finally decreasing. The minimum S R values of GCBaF 2 (GCB), GCCaF 2 (GCC) and GCSrF 2 (GCS) were 2.8 × 10 -4 , 0.8 × 10 -4 and 1.9 × 10 - 4  K -1 at 360, 269 and 319 K, respectively. Glass ceramics with an intense emission intensity can be used to convert the measured spectrum into temperature and may have an important role in temperature detectors. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Stress intensity factors for deep cracks emanating from the corner formed by a hole intersecting a plate surface

    NASA Technical Reports Server (NTRS)

    Mcgowan, J. J.; Smith, C. W.

    1974-01-01

    A technique consisting of freezing photo-elasticity and a numerical method was used to obtain stress intensity factors for natural cracks emanating from the corner at which a hole intersects a plate surface. Geometries studied were: (1) crack depth to thickness ratios of approximately 0.2, (2) 0.5 and 0.75; (3) crack depth to crack length ratios of approximately 1.0 to 2.0; and (4) crack length to hole radius ratios of about 0.5 to 2.0. All final crack geometries were grown under monotonic loading and growth was not self similar, with most of the growth occuring through the thickness under remote extension. Stress intensity factors were determined at the intersection of the flaw border.

  15. Analysis of multicrystal pump–probe data sets. I. Expressions for the RATIO model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fournier, Bertrand; Coppens, Philip

    2014-08-30

    The RATIO method in time-resolved crystallography [Coppenset al.(2009).J. Synchrotron Rad.16, 226–230] was developed for use with Laue pump–probe diffraction data to avoid complex corrections due to wavelength dependence of the intensities. The application of the RATIO method in processing/analysis prior to structure refinement requires an appropriate ratio model for modeling the light response. The assessment of the accuracy of pump–probe time-resolved structure refinements based on the observed ratios was discussed in a previous paper. In the current paper, a detailed ratio model is discussed, taking into account both geometric and thermal light-induced changes.

  16. Recruitment of single muscle fibers during submaximal cycling exercise.

    PubMed

    Altenburg, T M; Degens, H; van Mechelen, W; Sargeant, A J; de Haan, A

    2007-11-01

    In literature, an inconsistency exists in the submaximal exercise intensity at which type II fibers are activated. In the present study, the recruitment of type I and II fibers was investigated from the very beginning and throughout a 45-min cycle exercise at 75% of the maximal oxygen uptake, which corresponded to 38% of the maximal dynamic muscle force. Biopsies of the vastus lateralis muscle were taken from six subjects at rest and during the exercise, two at each time point. From the first biopsy single fibers were isolated and characterized as type I and II, and phosphocreatine-to-creatine (PCr/Cr) ratios and periodic acid-Schiff (PAS) stain intensities were measured. Cross sections were cut from the second biopsy, individual fibers were characterized as type I and II, and PAS stain intensities were measured. A decline in PCr/Cr ratio and in PAS stain intensity was used as indication of fiber recruitment. Within 1 min of exercise both type I and, although to a lesser extent, type II fibers were recruited. Furthermore, the PCr/Cr ratio revealed that the same proportion of fibers was recruited during the whole 45 min of exercise, indicating a rather constant recruitment. The PAS staining, however, proved inadequate to fully demonstrate fiber recruitment even after 45 min of exercise. We conclude that during cycling exercise a greater proportion of type II fibers is recruited than previously reported for isometric contractions, probably because of the dynamic character of the exercise. Furthermore, the PCr/Cr ratio method is more sensitive in determining fiber activation than the PAS stain intensity method.

  17. The RATIO method for time-resolved Laue crystallography

    PubMed Central

    Coppens, Philip; Pitak, Mateusz; Gembicky, Milan; Messerschmidt, Marc; Scheins, Stephan; Benedict, Jason; Adachi, Shin-ichi; Sato, Tokushi; Nozawa, Shunsuke; Ichiyanagi, Kohei; Chollet, Matthieu; Koshihara, Shin-ya

    2009-01-01

    A RATIO method for analysis of intensity changes in time-resolved pump–probe Laue diffraction experiments is described. The method eliminates the need for scaling the data with a wavelength curve representing the spectral distribution of the source and removes the effect of possible anisotropic absorption. It does not require relative scaling of series of frames and removes errors due to all but very short term fluctuations in the synchrotron beam. PMID:19240334

  18. Adaptive optimization of reference intensity for optical coherence imaging using galvanometric mirror tilting method

    NASA Astrophysics Data System (ADS)

    Kim, Ji-hyun; Han, Jae-Ho; Jeong, Jichai

    2015-09-01

    Integration time and reference intensity are important factors for achieving high signal-to-noise ratio (SNR) and sensitivity in optical coherence tomography (OCT). In this context, we present an adaptive optimization method of reference intensity for OCT setup. The reference intensity is automatically controlled by tilting a beam position using a Galvanometric scanning mirror system. Before sample scanning, the OCT system acquires two dimensional intensity map with normalized intensity and variables in color spaces using false-color mapping. Then, the system increases or decreases reference intensity following the map data for optimization with a given algorithm. In our experiments, the proposed method successfully corrected the reference intensity with maintaining spectral shape, enabled to change integration time without manual calibration of the reference intensity, and prevented image degradation due to over-saturation and insufficient reference intensity. Also, SNR and sensitivity could be improved by increasing integration time with automatic adjustment of the reference intensity. We believe that our findings can significantly aid in the optimization of SNR and sensitivity for optical coherence tomography systems.

  19. Estimation of S/G ratio in woods using 1064 nm FT-Raman spectroscopy

    Treesearch

    Umesh P. Agarwal; Sally A. Ralph; Dharshana Padmakshan; Sarah Liu; Steven D. Karlen; Cliff Foster; John Ralph

    2015-01-01

    Two simple methods based on the 370 cm-1 Raman band intensity were developed for estimation of syringyl-to-guaiacyl (S/G) ratio in woods. The methods, in principle, are representative of the whole cell wall lignin and not just the portion of lignin that gets cleaved to release monomers, for example, during certain S/G chemical analyses. As such,...

  20. Application of laser-induced autofluorescence spectra detection system in human colorectal cancer in-vivo screening

    NASA Astrophysics Data System (ADS)

    Chia, Teck Chee; Fu, Sheng; Chia, Yee Hong; Kwek, Leong Chuan; Tang, Choong Leong

    2005-09-01

    This study aimed at applying Laser induced-autofluorescence (LIAF) diagnostics method as an in-vivo screening of colorectal polyplcancer. The spectrum algorithm based on the ratio of autofluorescence intensity was used to identify the diseased tissues from the normal tissues as it was generally performed better than an algorithm based only simply on the intensity of the spectrum. Histopathological biopsy results were compared with the detected AF spectra characteristics for different kinds of polyps. 73 patients had been examined via the LIAF spectroscopy detection system during their colonoscopy screening in Endoscopy Center, Singapore General Hospital. The autofluorescence from the surface of the colorectal tissues under 405 nm laser light excitation was detected using our detecting system. In the experimental investigation two groups of patients were involved. One group was "abnormal" group. There were 25 patients belonging to this group since polyps or carcinoma was found in their colorectal tract during colonoscopy. The histopathology reports confirm the group classification. Total 36 polyps' AF spectra and 9 carcinoma' AF spectra were detected from 25 patients of the abnormal group during their regular endoscopy examination. The intensity ratios RI-680/I-500 and RI-630/I-500 of polyps/cancerous AF spectra and intensity ratios of corresponding normal colorectal AF spectra were calculated. Two critical intensity ratios for separating the AF intensity ratios RI-680/I-500 and RI-630/I-500 of normal and abnormal colorectal tissues were defined as 0.5 and 0.6 respectively. Using the critical intensity ratio values, 48 "normal" group patients' rectums were checked via the LIAF detection system. There were 20 patients (41.7%) whose AF spectra of colorectal tract mucosa belonging to abnormal spectra. However, these 20 patients had not been found under white light via traditional endoscopy. For small diseased area like small plat polyp disease and carcinoma, it was very difficult to identify under white light by endoscopy. However, the LIAF spectra technique and AF intensity ratio algorithm was able to detect these kinds of abnormal area earlier than traditional endoscopy. Using this algorithm, it is able to identify the onset of abnormal tissue growth during real-time clinical endoscope examination.

  1. Dynamics of the Polar Mesopause and Lower Thermosphere Region as Observed in the Night Airglow Emissions

    DTIC Science & Technology

    1988-02-01

    feasible. However, only the winter 80-110 km region could be studied by this approach, due to the limitation in the observing method , i.e. nightglow...epoch methods have been employed. The diurnal tide component at the mesopause, that according to the latest tidal models should dominate in polar region...temperature was calculated by Kvifte’s method . tweem temperature and intensity was found by Shaqae [1974] using the intensity ratio of the P,(2) and P,(3

  2. Scaled signal intensity of uterine fibroids based on T2-weighted MR images: a potential objective method to determine the suitability for magnetic resonance-guided focused ultrasound surgery of uterine fibroids.

    PubMed

    Park, Hyun; Yoon, Sang-Wook; Sokolov, Amit

    2015-12-01

    Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) is a non-invasive method to treat uterine fibroids. To help determine the patient suitability for MRgFUS, we propose a new objective measure: the scaled signal intensity (SSI) of uterine fibroids in T2 weighted MR images (T2WI). Forty three uterine fibroids in 40 premenopausal women were included in this retrospective study. SSI of each fibroid was measured from the screening T2WI by standardizing its mean signal intensity to a 0-100 scale, using reference intensities of rectus abdominis muscle (0) and subcutaneous fat (100). Correlation between the SSI and the non-perfused volume (NPV) ratio (a measure for treatment success) was calculated. Pre-treatment SSI showed a significant inverse-correlation with post treatment NPV ratio (p < 0.05). When dichotomizing NPV ratio at 45 %, the optimal cut off value of the SSI was found to be 16.0. A fibroid with SSI value 16.0 or less can be expected to have optimal responses. The SSI of uterine fibroids in T2WI can be suggested as an objective parameter to help in patient selection for MRgFUS. • Signal intensity of fibroid in MR images predicts treatment response to MRgFUS. • Signal intensity is standardized into scaled form using adjacent tissues as references. • Fibroids with SSI less than 16.0 are expected to have optimal responses.

  3. Numerical evaluation of equivalence ratio measurement using OH{sup *} and CH{sup *} chemiluminescence in premixed and non-premixed methane-air flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panoutsos, C.S.; Hardalupas, Y.; Taylor, A.M.K.P.

    This work presents results from detailed chemical kinetics calculations of electronically excited OH (A{sup 2}{sigma}, denoted as OH{sup *}) and CH (A{sup 2}{delta}, denoted as CH{sup *}) chemiluminescent species in laminar premixed and non-premixed counterflow methane-air flames, at atmospheric pressure. Eight different detailed chemistry mechanisms, with added elementary reactions that account for the formation and destruction of the chemiluminescent species OH{sup *} and CH{sup *}, are studied. The effects of flow strain rate and equivalence ratio on the chemiluminescent intensities of OH{sup *}, CH{sup *} and their ratio are studied and the results are compared to chemiluminescent intensity ratio measurementsmore » from premixed laminar counterflow natural gas-air flames. This is done in order to numerically evaluate the measurement of equivalence ratio using OH{sup *} and CH{sup *} chemiluminescence, an experimental practise that is used in the literature. The calculations reproduced the experimental observation that there is no effect of strain rate on the chemiluminescent intensity ratio of OH{sup *} to CH{sup *}, and that the ratio is a monotonic function of equivalence ratio. In contrast, the strain rate was found to have an effect on both the OH{sup *} and CH{sup *} intensities, in agreement with experiment. The calculated OH{sup *}/CH{sup *} values showed that only five out of the eight mechanisms studied were within the same order of magnitude with the experimental data. A new mechanism, proposed in this work, gave results that agreed with experiment within 30%. It was found that the location of maximum emitted intensity from the excited species OH{sup *} and CH{sup *} was displaced by less than 65 and 115 {mu}m, respectively, away from the maximum of the heat release rate, in agreement with experiments, which is small relative to the spatial resolution of experimental methods applied to combustion applications, and, therefore, it is expected that intensity from the OH{sup *} and CH{sup *} excited radicals can be used to identify the location of the reaction zone. Calculations of the OH{sup *}/CH{sup *} intensity ratio for strained non-premixed counterflow methane-air flames showed that the intensity ratio takes different values from those for premixed flames, and therefore has the potential to be used as a criterion to distinguish between premixed and non-premixed reaction in turbulent flames. (author)« less

  4. Blood perfusion and pH monitoring in organs by laser-induced fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Vari, Sandor G.; Papazoglou, Theodore G.; Pergadia, Vani R.; Stavridi, Marigo; Snyder, Wendy J.; Papaioannou, Thanassis; Duffy, J. T.; Weiss, Andrew B.; Thomas, Reem; Grundfest, Warren S.

    1994-01-01

    Sensitivity of laser-induced fluorescence spectroscopy (LIFS) in detecting a change in tissue pH, and blood perfusion was determined. Rabbits were anesthetized, paralyzed, and mechanically ventilated. The arterial and venous blood supplies of the kidney were isolated and ligated to alter the perfusion. The femoral artery was cannulated to extract samples for blood gas analysis. A 308-nm XeCl was used as an excitation source. A 600 micrometers core diameter fiber was used for fluorescence acquisition, and the spectra analyzed by an optical multichannel analyzer (EG & G, OMA III). the corresponding intensity ratio R equals INADH / ICOLL was used as an index for respiratory acidosis. Blood perfusion was assessed using the following algorithm: (IELAS minus ICOLL) divided by (INADH minus ICOLL). The intensity ratio linearly decreased with the reduction of blood perfusion. When we totally occluded the artery the ratio decreased tenfold when compared to the ratio of a fully perfused kidney. Results of monitoring blood acidosis by laser-induced fluorescence spectroscopy shows a significant trend between pH and intensity ratio. Since all the slopes were negative, there is an obvious significant correlation between the pH and NADH.COLLAGEN RATIO. Blue-light-induced fluorescence measurements and ratio fluorometry is a sensitive method for monitoring blood perfusion and acidity or alkalinity of an organ.

  5. Method for measuring recovery of catalytic elements from fuel cells

    DOEpatents

    Shore, Lawrence [Edison, NJ; Matlin, Ramail [Berkeley, NJ

    2011-03-08

    A method is provided for measuring the concentration of a catalytic clement in a fuel cell powder. The method includes depositing on a porous substrate at least one layer of a powder mixture comprising the fuel cell powder and an internal standard material, ablating a sample of the powder mixture using a laser, and vaporizing the sample using an inductively coupled plasma. A normalized concentration of catalytic element in the sample is determined by quantifying the intensity of a first signal correlated to the amount of catalytic element in the sample, quantifying the intensity of a second signal correlated to the amount of internal standard material in the sample, and using a ratio of the first signal intensity to the second signal intensity to cancel out the effects of sample size.

  6. Retrieval of Total Ozone Amounts from Zenith-Sky Intensities in the Ultraviolet Region

    NASA Technical Reports Server (NTRS)

    Bojkov, B. R.; Bhartia, P. K.; Hilsenrath, E.; Labow, G. J.

    2004-01-01

    A new method to determine the total ozone column from zenith-sky intensities in the ultraviolet region has been developed for the Shuttle Solar Backscatter Ultraviolet Spectrometer (SSBUV) operating at the NASA Goddard Space Flight Center. The total ozone column amounts are derived by comparing the ratio of measured intensities from three wavelengths with the equivalent ratios calculated by a radiative transfer model. The differences between the retrieved ozone column amounts and the collocated Brewer double monochromator are within 2% for the measurement period beginning in April 2001. The methodology, as well as the influences of the ozone profiles, aerosols, surface albedo, and the solar zenith angle on the retrieved total ozone amounts will be presented.

  7. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    PubMed Central

    Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni

    2012-01-01

    Objective Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Materials and Methods Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. Results A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. Conclusion The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials. PMID:22778560

  8. High-throughput measurements of the optical redox ratio using a commercial microplate reader.

    PubMed

    Cannon, Taylor M; Shah, Amy T; Walsh, Alex J; Skala, Melissa C

    2015-01-01

    There is a need for accurate, high-throughput, functional measures to gauge the efficacy of potential drugs in living cells. As an early marker of drug response in cells, cellular metabolism provides an attractive platform for high-throughput drug testing. Optical techniques can noninvasively monitor NADH and FAD, two autofluorescent metabolic coenzymes. The autofluorescent redox ratio, defined as the autofluorescence intensity of NADH divided by that of FAD, quantifies relative rates of cellular glycolysis and oxidative phosphorylation. However, current microscopy methods for redox ratio quantification are time-intensive and low-throughput, limiting their practicality in drug screening. Alternatively, high-throughput commercial microplate readers quickly measure fluorescence intensities for hundreds of wells. This study found that a commercial microplate reader can differentiate the receptor status of breast cancer cell lines (p < 0.05) based on redox ratio measurements without extrinsic contrast agents. Furthermore, microplate reader redox ratio measurements resolve response (p < 0.05) and lack of response (p > 0.05) in cell lines that are responsive and nonresponsive, respectively, to the breast cancer drug trastuzumab. These studies indicate that the microplate readers can be used to measure the redox ratio in a high-throughput manner and are sensitive enough to detect differences in cellular metabolism that are consistent with microscopy results.

  9. Metal alloy identifier

    DOEpatents

    Riley, William D.; Brown, Jr., Robert D.

    1987-01-01

    To identify the composition of a metal alloy, sparks generated from the alloy are optically observed and spectrographically analyzed. The spectrographic data, in the form of a full-spectrum plot of intensity versus wavelength, provide the "signature" of the metal alloy. This signature can be compared with similar plots for alloys of known composition to establish the unknown composition by a positive match with a known alloy. An alternative method is to form intensity ratios for pairs of predetermined wavelengths within the observed spectrum and to then compare the values of such ratios with similar values for known alloy compositions, thereby to positively identify the unknown alloy composition.

  10. Method for thermal and structural evaluation of shallow intense-beam deposition in matter

    NASA Astrophysics Data System (ADS)

    Pilan Zanoni, André

    2018-05-01

    The projected range of high-intensity proton and heavy-ion beams at energies below a few tens of MeV/A in matter can be as short as a few micrometers. For the evaluation of temperature and stresses from a shallow beam energy deposition in matter conventional numerical 3D models require minuscule element sizes for acceptable element aspect ratio as well as extremely short time steps for numerical convergence. In order to simulate energy deposition using a manageable number of elements this article presents a method using layered elements. This method is applied to beam stoppers and accidental intense-beam impact onto UHV sector valves. In those cases the thermal results from the new method are congruent to those from conventional solid-element and adiabatic models.

  11. Phase retrieval using regularization method in intensity correlation imaging

    NASA Astrophysics Data System (ADS)

    Li, Xiyu; Gao, Xin; Tang, Jia; Lu, Changming; Wang, Jianli; Wang, Bin

    2014-11-01

    Intensity correlation imaging(ICI) method can obtain high resolution image with ground-based low precision mirrors, in the imaging process, phase retrieval algorithm should be used to reconstituted the object's image. But the algorithm now used(such as hybrid input-output algorithm) is sensitive to noise and easy to stagnate. However the signal-to-noise ratio of intensity interferometry is low especially in imaging astronomical objects. In this paper, we build the mathematical model of phase retrieval and simplified it into a constrained optimization problem of a multi-dimensional function. New error function was designed by noise distribution and prior information using regularization method. The simulation results show that the regularization method can improve the performance of phase retrieval algorithm and get better image especially in low SNR condition

  12. High extinction ratio integrated optical modulator for quantum telecommunication systems

    NASA Astrophysics Data System (ADS)

    Tronev, A.; Parfenov, M.; Agruzov, P.; Ilichev, I.; Shamray, A.

    2018-01-01

    A method for increasing the extinction ratio of integrated optical Mach-Zehnder modulators based on LiNbO3 via the photorefractive effect is proposed. The influence of the photorefractive effect on the X- and Y-splitters of intensity modulators is experimentally studied. An increase in the modulator extinction ratio by 17 dB (from 30 to 47 dB) is obtained. It is shown that fabricated modulators with a high extinction ratio are important for quantum key distribution systems.

  13. Effect modification of the association of cumulative exposure and cancer risk by intensity of exposure and time since exposure cessation: a flexible method applied to cigarette smoking and lung cancer in the SYNERGY Study.

    PubMed

    Vlaanderen, Jelle; Portengen, Lützen; Schüz, Joachim; Olsson, Ann; Pesch, Beate; Kendzia, Benjamin; Stücker, Isabelle; Guida, Florence; Brüske, Irene; Wichmann, Heinz-Erich; Consonni, Dario; Landi, Maria Teresa; Caporaso, Neil; Siemiatycki, Jack; Merletti, Franco; Mirabelli, Dario; Richiardi, Lorenzo; Gustavsson, Per; Plato, Nils; Jöckel, Karl-Heinz; Ahrens, Wolfgang; Pohlabeln, Hermann; Tardón, Adonina; Zaridze, David; Field, John K; 't Mannetje, Andrea; Pearce, Neil; McLaughlin, John; Demers, Paul; Szeszenia-Dabrowska, Neonila; Lissowska, Jolanta; Rudnai, Peter; Fabianova, Eleonora; Stanescu Dumitru, Rodica; Bencko, Vladimir; Foretova, Lenka; Janout, Vladimir; Boffetta, Paolo; Forastiere, Francesco; Bueno-de-Mesquita, Bas; Peters, Susan; Brüning, Thomas; Kromhout, Hans; Straif, Kurt; Vermeulen, Roel

    2014-02-01

    The indiscriminate use of the cumulative exposure metric (the product of intensity and duration of exposure) might bias reported associations between exposure to hazardous agents and cancer risk. To assess the independent effects of duration and intensity of exposure on cancer risk, we explored effect modification of the association of cumulative exposure and cancer risk by intensity of exposure. We applied a flexible excess odds ratio model that is linear in cumulative exposure but potentially nonlinear in intensity of exposure to 15 case-control studies of cigarette smoking and lung cancer (1985-2009). Our model accommodated modification of the excess odds ratio per pack-year of cigarette smoking by time since smoking cessation among former smokers. We observed negative effect modification of the association of pack-years of cigarette smoking and lung cancer by intensity of cigarette smoke for persons who smoked more than 20-30 cigarettes per day. Patterns of effect modification were similar across individual studies and across major lung cancer subtypes. We observed strong negative effect modification by time since smoking cessation. Application of our method in this example of cigarette smoking and lung cancer demonstrated that reducing a complex exposure history to a metric such as cumulative exposure is too restrictive.

  14. Effect Modification of the Association of Cumulative Exposure and Cancer Risk by Intensity of Exposure and Time Since Exposure Cessation: A Flexible Method Applied to Cigarette Smoking and Lung Cancer in the SYNERGY Study

    PubMed Central

    Vlaanderen, Jelle; Portengen, Lützen; Schüz, Joachim; Olsson, Ann; Pesch, Beate; Kendzia, Benjamin; Stücker, Isabelle; Guida, Florence; Brüske, Irene; Wichmann, Heinz-Erich; Consonni, Dario; Landi, Maria Teresa; Caporaso, Neil; Siemiatycki, Jack; Merletti, Franco; Mirabelli, Dario; Richiardi, Lorenzo; Gustavsson, Per; Plato, Nils; Jöckel, Karl-Heinz; Ahrens, Wolfgang; Pohlabeln, Hermann; Tardón, Adonina; Zaridze, David; Field, John K.; 't Mannetje, Andrea; Pearce, Neil; McLaughlin, John; Demers, Paul; Szeszenia-Dabrowska, Neonila; Lissowska, Jolanta; Rudnai, Peter; Fabianova, Eleonora; Stanescu Dumitru, Rodica; Bencko, Vladimir; Foretova, Lenka; Janout, Vladimir; Boffetta, Paolo; Forastiere, Francesco; Bueno-de-Mesquita, Bas; Peters, Susan; Brüning, Thomas; Kromhout, Hans; Straif, Kurt; Vermeulen, Roel

    2014-01-01

    The indiscriminate use of the cumulative exposure metric (the product of intensity and duration of exposure) might bias reported associations between exposure to hazardous agents and cancer risk. To assess the independent effects of duration and intensity of exposure on cancer risk, we explored effect modification of the association of cumulative exposure and cancer risk by intensity of exposure. We applied a flexible excess odds ratio model that is linear in cumulative exposure but potentially nonlinear in intensity of exposure to 15 case-control studies of cigarette smoking and lung cancer (1985–2009). Our model accommodated modification of the excess odds ratio per pack-year of cigarette smoking by time since smoking cessation among former smokers. We observed negative effect modification of the association of pack-years of cigarette smoking and lung cancer by intensity of cigarette smoke for persons who smoked more than 20–30 cigarettes per day. Patterns of effect modification were similar across individual studies and across major lung cancer subtypes. We observed strong negative effect modification by time since smoking cessation. Application of our method in this example of cigarette smoking and lung cancer demonstrated that reducing a complex exposure history to a metric such as cumulative exposure is too restrictive. PMID:24355332

  15. INTEGRAL/SPI data segmentation to retrieve source intensity variations

    NASA Astrophysics Data System (ADS)

    Bouchet, L.; Amestoy, P. R.; Buttari, A.; Rouet, F.-H.; Chauvin, M.

    2013-07-01

    Context. The INTEGRAL/SPI, X/γ-ray spectrometer (20 keV-8 MeV) is an instrument for which recovering source intensity variations is not straightforward and can constitute a difficulty for data analysis. In most cases, determining the source intensity changes between exposures is largely based on a priori information. Aims: We propose techniques that help to overcome the difficulty related to source intensity variations, which make this step more rational. In addition, the constructed "synthetic" light curves should permit us to obtain a sky model that describes the data better and optimizes the source signal-to-noise ratios. Methods: For this purpose, the time intensity variation of each source was modeled as a combination of piecewise segments of time during which a given source exhibits a constant intensity. To optimize the signal-to-noise ratios, the number of segments was minimized. We present a first method that takes advantage of previous time series that can be obtained from another instrument on-board the INTEGRAL observatory. A data segmentation algorithm was then used to synthesize the time series into segments. The second method no longer needs external light curves, but solely SPI raw data. For this, we developed a specific algorithm that involves the SPI transfer function. Results: The time segmentation algorithms that were developed solve a difficulty inherent to the SPI instrument, which is the intensity variations of sources between exposures, and it allows us to obtain more information about the sources' behavior. Based on observations with INTEGRAL, an ESA project with instruments and science data centre funded by ESA member states (especially the PI countries: Denmark, France, Germany, Italy, Spain, and Switzerland), Czech Republic and Poland with participation of Russia and the USA.

  16. Self-adaptive demodulation for polarization extinction ratio in distributed polarization coupling.

    PubMed

    Zhang, Hongxia; Ren, Yaguang; Liu, Tiegen; Jia, Dagong; Zhang, Yimo

    2013-06-20

    A self-adaptive method for distributed polarization extinction ratio (PER) demodulation is demonstrated. It is characterized by dynamic PER threshold coupling intensity (TCI) and nonuniform PER iteration step length (ISL). Based on the preset PER calculation accuracy and original distribution coupling intensity, TCI and ISL can be made self-adaptive to determine contributing coupling points inside the polarizing devices. Distributed PER is calculated by accumulating those coupling points automatically and selectively. Two different kinds of polarization-maintaining fibers are tested, and PERs are obtained after merely 3-5 iterations using the proposed method. Comparison experiments with Thorlabs commercial instrument are also conducted, and results show high consistency. In addition, the optimum preset PER calculation accuracy of 0.05 dB is obtained through many repeated experiments.

  17. Linear algebraic methods applied to intensity modulated radiation therapy.

    PubMed

    Crooks, S M; Xing, L

    2001-10-01

    Methods of linear algebra are applied to the choice of beam weights for intensity modulated radiation therapy (IMRT). It is shown that the physical interpretation of the beam weights, target homogeneity and ratios of deposited energy can be given in terms of matrix equations and quadratic forms. The methodology of fitting using linear algebra as applied to IMRT is examined. Results are compared with IMRT plans that had been prepared using a commercially available IMRT treatment planning system and previously delivered to cancer patients.

  18. Intensity ratio curve analysis of small renal masses on T2-weighted magnetic resonance imaging: Differentiation of fat-poor angiomyolipoma from renal cell carcinoma.

    PubMed

    Moriyama, Shingo; Yoshida, Soichiro; Tanaka, Hajime; Tanaka, Hiroshi; Yokoyama, Minato; Ishioka, Junichiro; Matsuoka, Yoh; Saito, Kazutaka; Kihara, Kazunori; Fujii, Yasuhisa

    2018-03-25

    To assess the diagnostic ability of a pixel intensity-based analysis in evaluating the magnetic resonance imaging characteristics of small renal masses, especially in differentiating fat-poor angiomyolipoma from renal cell carcinoma. T2-weighted images from 121 solid small renal masses (<4 cm) without visible fat (14 fat-poor angiomyolipomas, 92 clear cell renal cell carcinomas, six chromophobe renal cell carcinomas and nine papillary renal cell carcinomas) were retrospectively evaluated. An intensity ratio curve was plotted using intensity ratios, which were ratios of signal intensities of tumor pixels (each pixel along a linear region of interest drawn across the renal tumor on T2-weighted image) to the signal intensity of a normal renal cortex. The diagnostic ability of the intensity ratio curve analysis was evaluated. The tumors were classified into three types: intensity ratio fat-poor angiomyolipoma (n = 19) with no pseudocapsule, iso-low intensity and no heterogeneity; intensity ratio clear cell renal cell carcinoma (n = 76) with a pseudocapsule, iso-high intensity and heterogeneity; and other type of intensity ratio (n = 26), including tumors that did not fall into the above two categories. The sensitivity/specificity/accuracy of the intensity ratio curve analysis in diagnosing fat-poor angiomyolipoma was 93%/94%/94%, respectively. When the intensity ratio curve analysis was applied only to the tumor with undetermined radiological diagnosis, the sensitivity for diagnosing fat-poor angiomyolipoma compared with subjective reading alone significantly improved (93% vs 50%; P = 0.014). Our novel semiquantitative model for combined assessment of key features of fat-poor angiomyolipoma, including low intensity, homogeneity and absence of a pseudocapsule on T2-weighted image, might make diagnosis of fat-poor angiomyolipoma more accurate. © 2018 The Japanese Urological Association.

  19. Clinical Consideration of Treatment to Ablate Uterine Fibroids with Magnetic Resonance Imaging-guided High Intensity Focused Ultrasound (MRgFUS): Sonalleve

    PubMed Central

    Jeong, Jae-Hyeok; Hong, Gil Pyo; Kim, Yu-Ri; Ha, Jae-Eun

    2016-01-01

    Objectives Magnetic resonance imaging (MRI)-guided high intensity focused ultrasound surgery (MRgFUS) is a newly emerging non-invasive technique for the treatment of uterine fibroids. The purpose of this study is to review the clinical impact of MRgFUS. Methods This study examined 157 patients. The high intensity focused ultrasound (HIFU) utilized in this study was Philips Achieva 1.5 Tesla MR (Philips Healthcare, Best, the Netherlands) and Sonalleve HIFU system. The patients were followed in post-operative Month 1, Month 3, and Month 6 to investigate any change. Then, these were further classified according to the use of uterine stimulant (oxytocin) in parallel, Funaki Type of uterine fibroid, HIFU intensity, and non-perfused volume (NPV) ratio. Results When the uterine stimulant was utilized, the HIFU intensity was measured at significantly lower levels, compared with the group not using uterine stimulant, and treatment duration was significantly. The NPV ratio was found significantly higher in the group using uterine stimulant. Concerning the correlation between Funaki Type of uterine fibroid and average sonication power, it was found that the closer to Type I, the lower the sonication power, the shorter the treatment duration, and the higher the NPV ratio significantly. Conclusions In this study, it was found that the lower the Funaki Types of uterine fibroids, and the higher the NPV ratio immediately after the operation, the larger the uterine fibroid volume decrease and SSS change were. Also, if uterine stimulant was used in parallel in treatment, treatment duration and HIFU intensity could become shorter and lower. PMID:27617244

  20. Predicting Consistency of Meningioma by Magnetic Resonance Imaging

    PubMed Central

    Smith, Kyle A.; Leever, John D.; Chamoun, Roukoz B.

    2015-01-01

    Objective Meningioma consistency is important because it affects the difficulty of surgery. To predict preoperative consistency, several methods have been proposed; however, they lack objectivity and reproducibility. We propose a new method for prediction based on tumor to cerebellar peduncle T2-weighted imaging intensity (TCTI) ratios. Design The magnetic resonance (MR) images of 20 consecutive patients were evaluated preoperatively. An intraoperative consistency scale was applied to these lesions prospectively by the operating surgeon based on Cavitron Ultrasonic Surgical Aspirator (Valleylab, Boulder, Colorado, United States) intensity. Tumors were classified as A, very soft; B, soft/intermediate; or C, fibrous. Using T2-weighted MR sequence, the TCTI ratio was calculated. Tumor consistency grades and TCTI ratios were then correlated. Results Of the 20 tumors evaluated prospectively, 7 were classified as very soft, 9 as soft/intermediate, and 4 as fibrous. TCTI ratios for fibrous tumors were all ≤ 1; very soft tumors were ≥ 1.8, except for one outlier of 1.66; and soft/intermediate tumors were > 1 to < 1.8. Conclusion We propose a method using quantifiable region-of-interest TCTIs as a uniform and reproducible way to predict tumor consistency. The intraoperative consistency was graded in an objective and clinically significant way and could lead to more efficient tumor resection. PMID:26225306

  1. A comparison study of different excitation wavelengths to determine the relative content of key biomolecules in breast cancer and breast normal tissue

    NASA Astrophysics Data System (ADS)

    Sordillo, Laura A.; Sordillo, Peter P.; Budansky, Yury; Pu, Yang; Alfano, R. R.

    2015-03-01

    Fluorescence profiles from breast cancer and breast normal tissue samples with excitation wavelengths at 280 nm and 340 nm were obtained using the conventional LS-50 Perkin-Elmer spectrometer. Fluorescence ratios from these tissue samples, demonstrated by emission peaks at 340 nm, 440 nm and 460 nm and likely representing tryptophan and NADH, show increased relative content of tryptophan in malignant samples. Double ratio (DR) techniques were used to measure the severity of disease. The single excitation double ratio (Single-DR) method utilizes the emission intensity peaks from the spectrum acquired using a single excitation of 280 nm; while the dual excitation double ratio (dual-DR) method utilizes the emission intensity peaks from the spectra acquired using an excitation of 280 nm and 340 nm. Single-DR and dual-DR from 13 patients with breast carcinoma were compared in terms of their efficiency to distinguish high from low/intermediate tumors. Similar results were found with both methods. Results suggest that dual excitation wavelengths may be as effective as single excitation wavelength in calculating the relative content of biomolecules in breast cancer tissue, as well as for the assessment of the malignant potential of these tumors.

  2. Double sampling to estimate density and population trends in birds

    USGS Publications Warehouse

    Bart, Jonathan; Earnst, Susan L.

    2002-01-01

    We present a method for estimating density of nesting birds based on double sampling. The approach involves surveying a large sample of plots using a rapid method such as uncorrected point counts, variable circular plot counts, or the recently suggested double-observer method. A subsample of those plots is also surveyed using intensive methods to determine actual density. The ratio of the mean count on those plots (using the rapid method) to the mean actual density (as determined by the intensive searches) is used to adjust results from the rapid method. The approach works well when results from the rapid method are highly correlated with actual density. We illustrate the method with three years of shorebird surveys from the tundra in northern Alaska. In the rapid method, surveyors covered ~10 ha h-1 and surveyed each plot a single time. The intensive surveys involved three thorough searches, required ~3 h ha-1, and took 20% of the study effort. Surveyors using the rapid method detected an average of 79% of birds present. That detection ratio was used to convert the index obtained in the rapid method into an essentially unbiased estimate of density. Trends estimated from several years of data would also be essentially unbiased. Other advantages of double sampling are that (1) the rapid method can be changed as new methods become available, (2) domains can be compared even if detection rates differ, (3) total population size can be estimated, and (4) valuable ancillary information (e.g. nest success) can be obtained on intensive plots with little additional effort. We suggest that double sampling be used to test the assumption that rapid methods, such as variable circular plot and double-observer methods, yield density estimates that are essentially unbiased. The feasibility of implementing double sampling in a range of habitats needs to be evaluated.

  3. Optimized two- and three-colour laser pulses for the intense terahertz wave generation

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Wang, Guo-Li; Zhou, Xiao-Xin

    2016-11-01

    Based on the photocurrent model, we perform a theoretical study on the optimization of terahertz (THz) wave emission from argon gas irradiated by the two- and three-colour laser fields. To obtain stronger THz radiation for the given conditions, a genetic algorithm method is applied to search for the optimum laser parameters. For the two-colour field, our optimizations reveal two types of optimal scheme, and each one dominates the THz generation in different regions of intensity ratio for a given total laser intensity. One scheme is the combination of a fundamental laser pulse and its second harmonic, while the other is the fundamental pulse with its fourth harmonic. For each scheme, the optimal intensity ratio and phase delay are obtained. For the three-colour case, our optimization shows that the excellent waveform for the strongest THz radiation is composed of a fundamental laser pulse, and its second, third harmonics, with appropriate intensity ratio and carrier-envelope phase. Such a 3-colour field can generate strong THz radiation comparable with a 10-colour sawtooth wave [Martínez et al., Phys. Rev. Lett. 114, 183901 (2015)]. The physical mechanisms for the enhancement of THz wave emission in gases are also discussed in detail. Our results give helpful guidance for intense THz generation with tabletop femtosecond laser device in experiment.

  4. Mode 1 stress intensity factors for round compact specimens

    NASA Technical Reports Server (NTRS)

    Gross, B.

    1976-01-01

    The mode 1 stress intensity factors were computed for round compact specimens by the boundary collocation method. Results are presented for ratios A sub T/R sub 0 in the range 0.3 to 0.8, where A sub t is the distance from the specimen center to the crack tip for a specimen of diameter 2R sub 0.

  5. Column ratio mapping: a processing technique for atomic resolution high-angle annular dark-field (HAADF) images.

    PubMed

    Robb, Paul D; Craven, Alan J

    2008-12-01

    An image processing technique is presented for atomic resolution high-angle annular dark-field (HAADF) images that have been acquired using scanning transmission electron microscopy (STEM). This technique is termed column ratio mapping and involves the automated process of measuring atomic column intensity ratios in high-resolution HAADF images. This technique was developed to provide a fuller analysis of HAADF images than the usual method of drawing single intensity line profiles across a few areas of interest. For instance, column ratio mapping reveals the compositional distribution across the whole HAADF image and allows a statistical analysis and an estimation of errors. This has proven to be a very valuable technique as it can provide a more detailed assessment of the sharpness of interfacial structures from HAADF images. The technique of column ratio mapping is described in terms of a [110]-oriented zinc-blende structured AlAs/GaAs superlattice using the 1 angstroms-scale resolution capability of the aberration-corrected SuperSTEM 1 instrument.

  6. Image segmentation using joint spatial-intensity-shape features: application to CT lung nodule segmentation

    NASA Astrophysics Data System (ADS)

    Ye, Xujiong; Siddique, Musib; Douiri, Abdel; Beddoe, Gareth; Slabaugh, Greg

    2009-02-01

    Automatic segmentation of medical images is a challenging problem due to the complexity and variability of human anatomy, poor contrast of the object being segmented, and noise resulting from the image acquisition process. This paper presents a novel feature-guided method for the segmentation of 3D medical lesions. The proposed algorithm combines 1) a volumetric shape feature (shape index) based on high-order partial derivatives; 2) mean shift clustering in a joint spatial-intensity-shape (JSIS) feature space; and 3) a modified expectation-maximization (MEM) algorithm on the mean shift mode map to merge the neighboring regions (modes). In such a scenario, the volumetric shape feature is integrated into the process of the segmentation algorithm. The joint spatial-intensity-shape features provide rich information for the segmentation of the anatomic structures or lesions (tumors). The proposed method has been evaluated on a clinical dataset of thoracic CT scans that contains 68 nodules. A volume overlap ratio between each segmented nodule and the ground truth annotation is calculated. Using the proposed method, the mean overlap ratio over all the nodules is 0.80. On visual inspection and using a quantitative evaluation, the experimental results demonstrate the potential of the proposed method. It can properly segment a variety of nodules including juxta-vascular and juxta-pleural nodules, which are challenging for conventional methods due to the high similarity of intensities between the nodules and their adjacent tissues. This approach could also be applied to lesion segmentation in other anatomies, such as polyps in the colon.

  7. Measurement of circumsolar ratio in high dust loading regions using a photographic method

    NASA Astrophysics Data System (ADS)

    Al-Ansary, Hany; Shafiq, Talha; Rizvi, Arslan; El-Leathy, Abdelrahman

    2017-06-01

    Performance of concentrating solar power (CSP) plants is highly affected by direct normal irradiance (DNI). However, it is also important to consider circumsolar radiation in any simulation of a CSP plant, especially in desert regions where dust loading in the atmosphere is expected. There are a number of methods to measure circumsolar radiation. However, most of them require expensive instrumentation. This work introduces a simple method to estimate circumsolar radiation. It involves taking high-resolution photographs of the sun and processing them using a computer code that identifies the sun's disk. The code then uses pixel intensities to obtain the solar intensity distribution across the sun's disk and in the aureole region. The solar intensity distribution is then used to obtain the circumsolar ratio (CSR) which represents the shape of the sun. To test this method, numerous photos of the sun were taken during the month of April and September 2016 at King Saud University in Riyadh, Saudi Arabia. Riyadh is a region that is well known for high dust-loading, especially during the summer. Two days of different atmospheric conditions were selected in September for comparative analysis. Results show that this method produces repeatable results, and that the CSR can increase significantly due to high dust loading and passing clouds. The CSR is found to be a strong function of DNI, ranging from about 4.5% at DNI values above 800 W/m2 and increasing to as much as 8.5% when DNI drops to about 400 W/m2, due to passing clouds. Furthermore, the results show that circumsolar ratio tends to be high in the early morning and late afternoon due to the high air mass, while its values tend to be lowest around solar noon when the air mass is lowest.

  8. Techniques to derive geometries for image-based Eulerian computations

    PubMed Central

    Dillard, Seth; Buchholz, James; Vigmostad, Sarah; Kim, Hyunggun; Udaykumar, H.S.

    2014-01-01

    Purpose The performance of three frequently used level set-based segmentation methods is examined for the purpose of defining features and boundary conditions for image-based Eulerian fluid and solid mechanics models. The focus of the evaluation is to identify an approach that produces the best geometric representation from a computational fluid/solid modeling point of view. In particular, extraction of geometries from a wide variety of imaging modalities and noise intensities, to supply to an immersed boundary approach, is targeted. Design/methodology/approach Two- and three-dimensional images, acquired from optical, X-ray CT, and ultrasound imaging modalities, are segmented with active contours, k-means, and adaptive clustering methods. Segmentation contours are converted to level sets and smoothed as necessary for use in fluid/solid simulations. Results produced by the three approaches are compared visually and with contrast ratio, signal-to-noise ratio, and contrast-to-noise ratio measures. Findings While the active contours method possesses built-in smoothing and regularization and produces continuous contours, the clustering methods (k-means and adaptive clustering) produce discrete (pixelated) contours that require smoothing using speckle-reducing anisotropic diffusion (SRAD). Thus, for images with high contrast and low to moderate noise, active contours are generally preferable. However, adaptive clustering is found to be far superior to the other two methods for images possessing high levels of noise and global intensity variations, due to its more sophisticated use of local pixel/voxel intensity statistics. Originality/value It is often difficult to know a priori which segmentation will perform best for a given image type, particularly when geometric modeling is the ultimate goal. This work offers insight to the algorithm selection process, as well as outlining a practical framework for generating useful geometric surfaces in an Eulerian setting. PMID:25750470

  9. Counting missing values in a metabolite-intensity data set for measuring the analytical performance of a metabolomics platform.

    PubMed

    Huan, Tao; Li, Liang

    2015-01-20

    Metabolomics requires quantitative comparison of individual metabolites present in an entire sample set. Unfortunately, missing intensity values in one or more samples are very common. Because missing values can have a profound influence on metabolomic results, the extent of missing values found in a metabolomic data set should be treated as an important parameter for measuring the analytical performance of a technique. In this work, we report a study on the scope of missing values and a robust method of filling the missing values in a chemical isotope labeling (CIL) LC-MS metabolomics platform. Unlike conventional LC-MS, CIL LC-MS quantifies the concentration differences of individual metabolites in two comparative samples based on the mass spectral peak intensity ratio of a peak pair from a mixture of differentially labeled samples. We show that this peak-pair feature can be explored as a unique means of extracting metabolite intensity information from raw mass spectra. In our approach, a peak-pair peaking algorithm, IsoMS, is initially used to process the LC-MS data set to generate a CSV file or table that contains metabolite ID and peak ratio information (i.e., metabolite-intensity table). A zero-fill program, freely available from MyCompoundID.org , is developed to automatically find a missing value in the CSV file and go back to the raw LC-MS data to find the peak pair and, then, calculate the intensity ratio and enter the ratio value into the table. Most of the missing values are found to be low abundance peak pairs. We demonstrate the performance of this method in analyzing an experimental and technical replicate data set of human urine metabolome. Furthermore, we propose a standardized approach of counting missing values in a replicate data set as a way of gauging the extent of missing values in a metabolomics platform. Finally, we illustrate that applying the zero-fill program, in conjunction with dansylation CIL LC-MS, can lead to a marked improvement in finding significant metabolites that differentiate bladder cancer patients and their controls in a metabolomics study of 109 subjects.

  10. Characterization of a cartilage-like engineered biomass using a self-aggregating suspension culture model: molecular composition using FT-IRIS.

    PubMed

    Kim, Minwook; Kraft, Jeffrey J; Volk, Andrew C; Pugarelli, Joan; Pleshko, Nancy; Dodge, George R

    2011-12-01

    Maintenance of chondrocyte phenotype and robust expression and organization of macromolecular components with suitable cartilaginous properties is an ultimate goal in cartilage tissue engineering. We used a self-aggregating suspension culture (SASC) method to produce an engineered cartilage, "cartilage tissue analog" (CTA). With an objective of understanding the stability of phenotype of the CTA over long periods, we cultured chondrocytes up to 4 years and analyzed the matrix. Both early (eCTAs) (6 months) and aged (aCTAs) (4 years) showed type II collagen throughout with higher concentrations near the edge. Using Fourier transform-infrared imaging spectroscopy (FT-IRIS), proteoglycan/collagen ratio of eCTA was 2.8 times greater than native cartilage at 1 week, but the ratio was balanced to native level (p = 0.017) by 36 weeks. Surprisingly, aCTAs maintained the hyaline characteristics, but there was evidence of calcification within the tissue with a distinct range of intensities. Mineral/matrix ratio of those aCTA with "intensive" calcification was significantly higher (p = 0.017) than the "partial," but when compared to native bone the ratio of "intensive" aCTAs was 2.4 times lower. In this study we utilized the imaging approach of FT-IRIS and have shown that a biomaterial formed is compositionally closely related to natural cartilage for long periods in culture. We show that this culture platform can maintain a CTA for extended periods of time (4 years) and under those conditions signs of mineralization can be found. This method of cartilage tissue engineering is a promising method to generate cartilaginous biomaterial and may have potential to be utilized in both cartilage and boney repairs. Copyright © 2011 Orthopaedic Research Society.

  11. Earthquake mechanisms from linear-programming inversion of seismic-wave amplitude ratios

    USGS Publications Warehouse

    Julian, B.R.; Foulger, G.R.

    1996-01-01

    The amplitudes of radiated seismic waves contain far more information about earthquake source mechanisms than do first-motion polarities, but amplitudes are severely distorted by the effects of heterogeneity in the Earth. This distortion can be reduced greatly by using the ratios of amplitudes of appropriately chosen seismic phases, rather than simple amplitudes, but existing methods for inverting amplitude ratios are severely nonlinear and require computationally intensive searching methods to ensure that solutions are globally optimal. Searching methods are particularly costly if general (moment tensor) mechanisms are allowed. Efficient linear-programming methods, which do not suffer from these problems, have previously been applied to inverting polarities and wave amplitudes. We extend these methods to amplitude ratios, in which formulation on inequality constraint for an amplitude ratio takes the same mathematical form as a polarity observation. Three-component digital data for an earthquake at the Hengill-Grensdalur geothermal area in southwestern Iceland illustrate the power of the method. Polarities of P, SH, and SV waves, unusually well distributed on the focal sphere, cannot distinguish between diverse mechanisms, including a double couple. Amplitude ratios, on the other hand, clearly rule out the double-couple solution and require a large explosive isotropic component.

  12. [Optimal scan parameters for a method of k-space trajectory (radial scan method) in evaluation of carotid plaque characteristics].

    PubMed

    Nakamura, Manami; Makabe, Takeshi; Tezuka, Hideomi; Miura, Takahiro; Umemura, Takuma; Sugimori, Hiroyuki; Sakata, Motomichi

    2013-04-01

    The purpose of this study was to optimize scan parameters for evaluation of carotid plaque characteristics by k-space trajectory (radial scan method), using a custom-made carotid plaque phantom. The phantom was composed of simulated sternocleidomastoid muscle and four types of carotid plaque. The effect of chemical shift artifact was compared using T1 weighted images (T1WI) of the phantom obtained with and without fat suppression, and using two types of k-space trajectory (the radial scan method and the Cartesian method). The ratio of signal intensity of simulated sternocleidomastoid muscle to the signal intensity of hematoma, blood (including heparin), lard, and mayonnaise was compared among various repetition times (TR) using T1WI and T2 weighted imaging (T2WI). In terms of chemical shift artifacts, image quality was improved using fat suppression for both the radial scan and Cartesian methods. In terms of signal ratio, the highest values were obtained for the radial scan method with TR of 500 ms for T1WI, and TR of 3000 ms for T2WI. For evaluation of carotid plaque characteristics using the radial scan method, chemical shift artifacts were reduced with fat suppression. Signal ratio was improved by optimizing the TR settings for T1WI and T2WI. These results suggest the potential for using magnetic resonance imaging for detailed evaluation of carotid plaque.

  13. Luminescent Method for Porcelain Identification

    NASA Astrophysics Data System (ADS)

    Platova, R. A.; Rassulov, V. A.; Platov, Yu. T.

    2018-05-01

    Porcelain identification according to the material type (hard, soft, and bone) was reduced to a system of classification functions that were constructed based on interrelationships of luminescence band intensities of optically active impurity centers (Fe3+ and Mn2+), a molecular center ({UO}_2^{2+}) , and intrinsic defects (O*, oxygen center). Porcelains with different compositions and calcination conditions had different combinations and intensity ratios of bands of optically active centers.

  14. Intensity Biased PSP Measurement

    NASA Technical Reports Server (NTRS)

    Subramanian, Chelakara S.; Amer, Tahani R.; Oglesby, Donald M.; Burkett, Cecil G., Jr.

    2000-01-01

    The current pressure sensitive paint (PSP) technique assumes a linear relationship (Stern-Volmer Equation) between intensity ratio (I(sub 0)/I) and pressure ratio (P/P(sub 0)) over a wide range of pressures (vacuum to ambient or higher). Although this may be valid for some PSPs, in most PSPs the relationship is nonlinear, particularly at low pressures (less than 0.2 psia when the oxygen level is low). This non-linearity can be attributed to variations in the oxygen quenching (de-activation) rates (which otherwise is assumed constant) at these pressures. Other studies suggest that some paints also have non-linear calibrations at high pressures; because of heterogeneous (non-uniform) oxygen diffusion and c quenching. Moreover, pressure sensitive paints require correction for the output intensity due to light intensity variation, paint coating variation, model dynamics, wind-off reference pressure variation, and temperature sensitivity. Therefore to minimize the measurement uncertainties due to these causes, an in- situ intensity correction method was developed. A non-oxygen quenched paint (which provides a constant intensity at all pressures, called non-pressure sensitive paint, NPSP) was used for the reference intensity (I(sub NPSP)) with respect to which all the PSP intensities (I) were measured. The results of this study show that in order to fully reap the benefits of this technique, a totally oxygen impermeable NPSP must be available.

  15. Intensity Biased PSP Measurement

    NASA Technical Reports Server (NTRS)

    Subramanian, Chelakara S.; Amer, Tahani R.; Oglesby, Donald M.; Burkett, Cecil G., Jr.

    2000-01-01

    The current pressure sensitive paint (PSP) technique assumes a linear relationship (Stern-Volmer Equation) between intensity ratio (I(sub o)/I) and pressure ratio (P/P(sub o)) over a wide range of pressures (vacuum to ambient or higher). Although this may be valid for some PSPs, in most PSPs the relationship is nonlinear, particularly at low pressures (less than 0.2 psia when the oxygen level is low). This non-linearity can be attributed to variations in the oxygen quenching (de-activation) rates (which otherwise is assumed constant) at these pressures. Other studies suggest that some paints also have non-linear calibrations at high pressures; because of heterogeneous (non-uniform) oxygen diffusion and quenching. Moreover, pressure sensitive paints require correction for the output intensity due to light intensity variation, paint coating variation, model dynamics, wind-off reference pressure variation, and temperature sensitivity. Therefore to minimize the measurement uncertainties due to these causes, an insitu intensity correction method was developed. A non-oxygen quenched paint (which provides a constant intensity at all pressures, called non-pressure sensitive paint, NPSP) was used for the reference intensity (I(sub NPSP) with respect to which all the PSP intensities (I) were measured. The results of this study show that in order to fully reap the benefits of this technique, a totally oxygen impermeable NPSP must be available.

  16. The self-absorption effect of gamma rays in /sup 239/Pu

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, Hsiao-Hua

    1989-01-01

    Nuclear materials assay with gamma-ray spectrum measurement is a well-established method for safeguards. However, for a thick source, the self-absorption of characteristic low-energy gamma rays has been a handicap to accurate assay. I have carried out Monte Carlo simulations to study this effect using the /sup 239/Pu ..cap alpha..-decay gamma-ray spectrum as an example. The thickness of a plutonium metal source can be considered a function of gamma-ray intensity ratios. In a practical application, gamma-ray intensity ratios can be obtained from a measured spectrum. With the help of calculated curves, scientists can find the source thickness and make corrections tomore » gamma-ray intensities, which then lead to an accurate quantitative determination of radioactive isotopes in the material. 2 refs., 9 figs.« less

  17. Flow Cytometric Human Leukocyte Antigen-B27 Typing with Stored Samples for Batch Testing

    PubMed Central

    Seo, Bo Young

    2013-01-01

    Background Flow cytometry (FC) HLA-B27 typing is still used extensively for the diagnosis of spondyloarthropathies. If patient blood samples are stored for a prolonged duration, this testing can be performed in a batch manner, and in-house cellular controls could easily be procured. In this study, we investigated various methods of storing patient blood samples. Methods We compared four storage methods: three methods of analyzing lymphocytes (whole blood stored at room temperature, frozen mononuclear cells, and frozen white blood cells [WBCs] after lysing red blood cells [RBCs]), and one method using frozen platelets (FPLT). We used three ratios associated with mean fluorescence intensities (MFI) for HLAB27 assignment: the B27 MFI ratio (sample/control) for HLA-B27 fluorescein-5-isothiocyanate (FITC); the B7 MFI ratio for HLA-B7 phycoerythrin (PE); and the ratio of these two ratios, B7/B27 ratio. Results Comparing the B27 MFI ratios of each storage method for the HLA-B27+ samples and the B7/B27 ratios for the HLA-B7+ samples revealed that FPLT was the best of the four methods. FPLT had a sensitivity of 100% and a specificity of 99.3% for HLA-B27 assignment in DNA-typed samples (N=164) when the two criteria, namely, B27 MFI ratio >4.0 and B7/B27 ratio <1.5, were used. Conclusions The FPLT method was found to offer a simple, economical, and accurate method of FC HLA-B27 typing by using stored patient samples. If stored samples are used, this method has the potential to replace the standard FC typing method when used in combination with a complementary DNA-based method. PMID:23667843

  18. Geometry and solid angle corrections for accurate measurement of multipole and parity mixing ratios using nuclear orientation

    NASA Astrophysics Data System (ADS)

    Roccia, S.; Gaulard, C.; Étilé, A.; Chakma, R.

    2017-07-01

    In the context of nuclear orientation, we propose a new method to correct the multipole mixing ratios for asymmetries in the geometry of the setup but also in the detection system. This method is also robust against temperature fluctuations, beam intensity fluctuations and uncertainties in the nuclear structure of the nuclei. Additionally, this method provides a natural way to combine data from different detectors and make good use of all available statistics. We could use this method to demonstrate the accuracy that can be reached with the PolarEx setup now installed at the ALTO facility.

  19. Judd-Ofelt analysis and spectral properties of Dy3+ ions doped niobium containing tellurium calcium zinc borate glasses

    NASA Astrophysics Data System (ADS)

    Ravi, O.; Reddy, C. Madhukar; Reddy, B. Sudhakar; Deva Prasad Raju, B.

    2014-02-01

    Niobium containing tellurium calcium zinc borate (TCZNB) glasses doped with different concentrations of Dy3+ ions were prepared by the melt quenching method and their optical properties have been studied. The Judd-Ofelt (J-O) intensity parameters Ωt (t=2, 4 and 6) were calculated using the least square fit method. Based on the magnitude of Ω2 parameter the hypersensitivity of 6H15/2→6F11/2 has also been discussed. From the evaluated J-O intensity parameters as well as from the emission and lifetime measurements, radiative transition properties such as radiative transition probability rates and branching ratios were calculated for 4F9/2 excited level. It is found that for Dy3+ ion, the transition 4F9/2→6H13/2 shows highest emission cross-section at 1.0 mol% TCZNB glass matrix. From the visible luminescence spectra, yellow to blue (Y/B) intensity ratios and chromaticity color coordinates were also estimated. The TCZNB glasses exhibit good luminescence properties and are suitable for generation of white light.

  20. Ultrasonographic study of mechanosensory properties in human esophagus during mechanical distension

    PubMed Central

    Larsen, Ejnar; Reddy, Hariprasad; Drewes, Asbjørn Mohr; Arendt-Nielsen, Lars; Gregersen, Hans

    2006-01-01

    AIM: To study the esophageal geometry and mechanosensation using endoscopic ultrasonography during volume-controlled ramp distensions in the distal esophagus. METHODS: Twelve healthy volunteers underwent distension of a bag. During distension up to moderate pain the sensory intensity was assessed on a visual analogue scale (VAS). The esophageal deformation in terms of multidimensional stretch ratios and strains was calculated at different volumes and VAS levels. Distensions were done before and during administration of the anti-cholinergic drug butylscopolamine. RESULTS: The stimulus-response (volume-VAS) curve did not differ without or with the administration of butylscopolamine. Analysis of stretch ratios demonstrated tensile stretch in circumferential direction, compression in radial direction and a small tensile stretch in longitudinal direction. A strain gradient existed throughout the esophageal wall with the largest circumferential deformation at the mucosal surface. The sensation intensity increased exponentially as function of the strains. CONCLUSION: The method provides information of esophageal deformation gradients that correlate to the sensation intensity. Hence, it can be used to study mechanosensation in the human esophagus. Further studies are needed to determine the exact deformation stimulus for the esophageal mechanoreceptors. PMID:16874864

  1. Use of the product of mean intensity ratio (PMIR) technique for discriminant analysis of lycopene-rich vegetable juice using a portable NIR-excited Raman spectrometer.

    PubMed

    Hara, Risa; Ishigaki, Mika; Kitahama, Yasutaka; Ozaki, Yukihiro; Genkawa, Takuma

    2018-02-15

    In this study, a lycopene-content-based discriminant analysis was performed using a portable near-infrared-excited Raman spectrometer. In the vegetable-juice Raman spectra, the peak intensity of the lycopene band increased with increasing lycopene concentration, but scattering decreased the repeatability of the peak intensity. Consequently, developing a lycopene-concentration regression model using peak intensity is not straightforward. Therefore, a new method known as the product of mean intensity ratio (PMIR) analysis was developed to rapidly identify lycopene-rich samples on-site. In the PMIR analysis, Raman spectra are measured with short exposure times, confirming only the peaks of carotenoids with high concentrations, and thus the lycopene concentrations of vegetable juice samples could be determined successfully. Exposure times of 20ms and 100ms could detect lycopene concentrations of ≥5mg/100g and ≥2mg/100g with 93.2% and 97.7% accuracy, respectively; thus, lycopene-content-based discriminant analysis using the PMIR and a portable Raman spectrometer is feasible. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Methods for Broadband Spectral Analysis: Intrinsic Fluorescence Temperature Sensing as an Example.

    PubMed

    Zhang, Weiwei; Wang, Guoyao; Baxter, Greg W; Collins, Stephen F

    2017-06-01

    A systematic study was performed on the temperature-dependent fluorescence of (Ba,Sr) 2 SiO 4 :Eu 2+ . The barycenter and extended intensity ratio techniques were proposed to characterize the broadband fluorescence spectra. These techniques and other known methods (listed below) were employed and compared in the fluorescent temperature sensing experiment. Multiple sensing functions were obtained using the behaviors of: (1) the barycenter location of the emission band; (2) the emission bandwidth; and (3) the ratio of intensities at different wavelengths in the emission band, respectively. The barycenter technique was not limited by the spectrometer resolution and worked well while the peak location method failed. All the sensing functions were based on the intrinsic characteristics of the fluorescence of the phosphor and demonstrated nearly linear relationships with temperature in the measuring range. The multifunctional temperature-sensing abilities of the phosphor can be applied in a point thermometer or thermal mapping. The new techniques were validated successfully for characterizing various spectra.

  3. A gated Thomson parabola spectrometer for improved ion and neutral atom measurements in intense laser produced plasmas

    NASA Astrophysics Data System (ADS)

    Tata, Sheroy; Mondal, Angana; Sarkar, Soubhik; Lad, Amit D.; Krishnamurthy, M.

    2017-08-01

    Ions of high energy and high charge are accelerated from compact intense laser produced plasmas and are routinely analysed either by time of flight or Thomson parabola spectrometry. At the highest intensities where ion energies can be substantially large, both these techniques have limitations. Strong electromagnetic pulse noise jeopardises the arrival time measurement, and a bright central spot in the Thomson parabola spectrometer affects the signal to noise ratio of ion traces that approach close to the central spot. We present a gated Thomson parabola spectrometer that addresses these issues and provides an elegant method to improvise ion spectrometry. In addition, we demonstrate that this method provides the ability to detect and measure high energy neutral atoms that are invariably present in most intense laser plasma acceleration experiments.

  4. A gated Thomson parabola spectrometer for improved ion and neutral atom measurements in intense laser produced plasmas.

    PubMed

    Tata, Sheroy; Mondal, Angana; Sarkar, Soubhik; Lad, Amit D; Krishnamurthy, M

    2017-08-01

    Ions of high energy and high charge are accelerated from compact intense laser produced plasmas and are routinely analysed either by time of flight or Thomson parabola spectrometry. At the highest intensities where ion energies can be substantially large, both these techniques have limitations. Strong electromagnetic pulse noise jeopardises the arrival time measurement, and a bright central spot in the Thomson parabola spectrometer affects the signal to noise ratio of ion traces that approach close to the central spot. We present a gated Thomson parabola spectrometer that addresses these issues and provides an elegant method to improvise ion spectrometry. In addition, we demonstrate that this method provides the ability to detect and measure high energy neutral atoms that are invariably present in most intense laser plasma acceleration experiments.

  5. Determination of 13C/12C Isotope Ratio in Alcohols of Different Origin by 1н Nuclei NMR-Spectroscopy

    NASA Astrophysics Data System (ADS)

    Dzhimak, S. S.; Basov, A. A.; Buzko, V. Yu.; Kopytov, G. F.; Kashaev, D. V.; Shashkov, D. I.; Shlapakov, M. S.; Baryshev, M. G.

    2017-02-01

    A new express method of indirect assessment of 13C/12C isotope ratio on 1H nuclei is developed to verify the authenticity of ethanol origin in alcohol-water-based fluids and assess the facts of various alcoholic beverages falsification. It is established that in water-based alcohol-containing systems, side satellites for the signals of ethanol methyl and methylene protons in the NMR spectra on 1H nuclei, correspond to the protons associated with 13C nuclei. There is a direct correlation between the intensities of the signals of ethanol methyl and methylene protons' 1H- NMR and their side satellites, therefore, the data obtained can be used to assess 13C/12C isotope ratio in water-based alcohol-containing systems. The analysis of integrated intensities of main and satellite signals of methyl and methylene protons of ethanol obtained by NMR on 1H nuclei makes it possible to differentiate between ethanol of synthetic and natural origin. Furthermore, the method proposed made it possible to differentiate between wheat and corn ethanol.

  6. Cellulose I crystallinity determination using FT-Raman spectroscopy : univariate and multivariate methods

    Treesearch

    Umesh P. Agarwal; Richard S. Reiner; Sally A. Ralph

    2010-01-01

    Two new methods based on FT–Raman spectroscopy, one simple, based on band intensity ratio, and the other using a partial least squares (PLS) regression model, are proposed to determine cellulose I crystallinity. In the simple method, crystallinity in cellulose I samples was determined based on univariate regression that was first developed using the Raman band...

  7. Factors associated with success in the oral part of the European Diploma in Intensive Care

    PubMed Central

    Waldauf, Petr; Rubulotta, Francesca; Sitzwohl, Christian; Elbers, Paul; Girbes, Armand; Saha, Rajnish; Marsh, Brian; Kumar, Ravindra; Maggiorini, Marco

    2017-01-01

    Introduction The oral part of European Diploma in Intensive Care diploma examinations changed in 2013 into an objective structured clinical examination-type exam. This step was undertaken to provide a fair and reproducible clinical exam. All candidates face identical questions with predefined correct answers simultaneously in seven high throughput exam centres on the same day. We describe the factors that are associated with success in part 2 European Diploma in Intensive Care exam. Methods We prospectively collected self-reported data from all candidates sitting European Diploma in Intensive Care part 2 in 2015, namely demographics, professional background and attendance to a European Diploma in Intensive Care part 2 or generic objective structured clinical examination preparatory courses. After testing association with success (with cutoff at p < 0.10) and co-linearity of these factors as independent variables, we performed a multivariate logistical analysis, with binary exam outcome (pass/fail) as the dependent variable. Structural equation modelling was used to gain further insight into relations among determinants of success in the oral part of the European Diploma in Intensive Care. Results Out of 427 candidates sitting the exam, completed data from 341 (80%) were available for analysis. The following candidates' factors were associated with increased chance of success: English as native language (odds ratio 4.3 (95% CI 1.7–10.7)), use of Patient-centred Acute Care Training e-learning programme module (odds ratios 2.0 (1.2–3.3)), working in an EU country (odds ratios 2.5 (1.5–4.3)), and better results in the written part of the European Diploma in Intensive Care (for each additional SD of 6.1 points odds ratios 1.9 (1.4–2.4)). Chance of success in the European Diploma in Intensive Care 2 decreased with increased candidates ‘age (for each additional SD of 5.5 years odds ratios 0.67 (0.51–0.87)). Exam centres (7 in total) could be clustered into 3 groups with similar success rates. There were significant differences in exam outcomes among these 3 groups of exam centres even after adjustment to known candidates' factors (G1 vs G2 odds ratios 2.4 (1.4–4.1); G1 vs G3 odds ratios 9.7 (4.0–23.1) and G2 vs G3 odds ratios 3.9 (1.7–9.2)). A short data collection period (only one year) and 20% of missing candidates' data are the main limitations of this study. Conclusions Younger age, English as native language, better results in written part of the exam, working at a European country and the use of PACT for preparation, were factors associated with success in the oral part of the European Diploma in Intensive Care exam. Despite the limitations of this study, the differences in outcome among the exam centres will need further investigation. PMID:29123559

  8. Correlation between the local stress and the grain misorientation in the polycrystalline Al2O3 measured by near-field luminescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Tomimatsu, Toru; Takigawa, Ryo

    2018-06-01

    Owing to its high spatial resolution, near-field spectroscopy is a useful method for sensing the stress in a narrow region of submicron order. Here, on the basis of the highly resolved images obtained by near-field luminescence spectroscopy, we propose a statistical method of analyzing grain anisotropy-induced stress in polycrystalline Al2O3. We focus on two characteristics of a spectra: the intensity ratio and peak shift of luminescence of two lines (R1 and R2) from Al2O3 to discuss crystal orientation and stress, respectively. By incorporating the concept of the crystal misorientation parameter using intensity ratio, an apparent correlation between the magnitude of stress and the misorientation is found. This correlation analysis provides an important insight for the investigation of local thermal stress in Al2O3.

  9. Influence of signal intensity non-uniformity on brain volumetry using an atlas-based method.

    PubMed

    Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  10. Instrumental intensity distribution for the Hector Mine, California, and the Chi-Chi, Taiwan, earthquakes: Comparison of two methods

    USGS Publications Warehouse

    Sokolov, V.; Wald, D.J.

    2002-01-01

    We compare two methods of seismic-intensity estimation from ground-motion records for the two recent strong earthquakes: the 1999 (M 7.1) Hector Mine, California, and the 1999 (M 7.6) Chi-Chi, Taiwan. The first technique utilizes the peak ground acceleration (PGA) and velocity (PGV), and it is used for rapid generation of the instrumental intensity map in California. The other method is based on the revised relationships between intensity and Fourier amplitude spectrum (FAS). The results of using the methods are compared with independently observed data and between the estimations from the records. For the case of the Hector Mine earthquake, the calculated intensities in general agree with the observed values. For the case of the Chi-Chi earthquake, the areas of maximum calculated intensity correspond to the areas of the greatest damage and highest number of fatalities. However, the FAS method producees higher-intensity values than those of the peak amplitude method. The specific features of ground-motion excitation during the large, shallow, thrust earthquake may be considered a reason for the discrepancy. The use of PGA and PGV is simple; however, the use of FAS provides a natural consideration of site amplification by means of generalized or site-specific spectral ratios. Because the calculation of seismic-intensity maps requires rapid processing of data from a large network, it is very practical to generate a "first-order" map from the recorded peak motions. Then, a "second-order" map may be compiled using an amplitude-spectra method on the basis of available records and numerical modeling of the site-dependent spectra for the regions of sparse station spacing.

  11. Comparing transformation methods for DNA microarray data

    PubMed Central

    Thygesen, Helene H; Zwinderman, Aeilko H

    2004-01-01

    Background When DNA microarray data are used for gene clustering, genotype/phenotype correlation studies, or tissue classification the signal intensities are usually transformed and normalized in several steps in order to improve comparability and signal/noise ratio. These steps may include subtraction of an estimated background signal, subtracting the reference signal, smoothing (to account for nonlinear measurement effects), and more. Different authors use different approaches, and it is generally not clear to users which method they should prefer. Results We used the ratio between biological variance and measurement variance (which is an F-like statistic) as a quality measure for transformation methods, and we demonstrate a method for maximizing that variance ratio on real data. We explore a number of transformations issues, including Box-Cox transformation, baseline shift, partial subtraction of the log-reference signal and smoothing. It appears that the optimal choice of parameters for the transformation methods depends on the data. Further, the behavior of the variance ratio, under the null hypothesis of zero biological variance, appears to depend on the choice of parameters. Conclusions The use of replicates in microarray experiments is important. Adjustment for the null-hypothesis behavior of the variance ratio is critical to the selection of transformation method. PMID:15202953

  12. Comparing transformation methods for DNA microarray data.

    PubMed

    Thygesen, Helene H; Zwinderman, Aeilko H

    2004-06-17

    When DNA microarray data are used for gene clustering, genotype/phenotype correlation studies, or tissue classification the signal intensities are usually transformed and normalized in several steps in order to improve comparability and signal/noise ratio. These steps may include subtraction of an estimated background signal, subtracting the reference signal, smoothing (to account for nonlinear measurement effects), and more. Different authors use different approaches, and it is generally not clear to users which method they should prefer. We used the ratio between biological variance and measurement variance (which is an F-like statistic) as a quality measure for transformation methods, and we demonstrate a method for maximizing that variance ratio on real data. We explore a number of transformations issues, including Box-Cox transformation, baseline shift, partial subtraction of the log-reference signal and smoothing. It appears that the optimal choice of parameters for the transformation methods depends on the data. Further, the behavior of the variance ratio, under the null hypothesis of zero biological variance, appears to depend on the choice of parameters. The use of replicates in microarray experiments is important. Adjustment for the null-hypothesis behavior of the variance ratio is critical to the selection of transformation method.

  13. Aspect ratios and magma overpressures of non-feeder dikes observed in the Miyake-jima volcano (Japan), and fracture toughness of its upper part

    NASA Astrophysics Data System (ADS)

    Kusumoto, Shigekazu; Geshi, Nobuo; Gudmundsson, Agust

    2013-03-01

    present a new method for estimating the length and maximum thickness (aperture) of a dike from the observed opening at one dike tip. We apply the method to 15 arrested non-feeder dikes (where the upper tip is known, the lower tip unknown) in the caldera walls of Miyake-jima, Japan, to estimate the length-thickness ratio, as well as the magma overpressure and fracture toughness. The calculated length-thickness ratio ranges from 61 to 246, with an average of 136. The ratios are low because the dikes are emplaced close to the surface in comparatively compliant (soft) rocks. Using these ratios and the appropriate elastic constants, the calculated magmatic overpressures of the dikes are between 2.3 and 8.9 MPa, and the stress intensity factors between 38 and 117 MPa m1/2. All these values are within the range of typical in situ estimates, supporting the validity of this new method.

  14. The fluorescence intensities ratio is not a reliable parameter for evaluation of protein unfolding transitions.

    PubMed

    Žoldák, Gabriel; Jancura, Daniel; Sedlák, Erik

    2017-06-01

    Monitoring the fluorescence of proteins, particularly the fluorescence of intrinsic tryptophan residues, is a popular method often used in the analysis of unfolding transitions (induced by temperature, chemical denaturant, and pH) in proteins. The tryptophan fluorescence provides several suitable parameters, such as steady-state fluorescence intensity, apparent quantum yield, mean fluorescence lifetime, position of emission maximum that are often utilized for the observation of the conformational/unfolding transitions of proteins. In addition, the fluorescence intensities ratio at different wavelengths (usually at 330 nm and 350 nm) is becoming an increasingly popular parameter for the evaluation of thermal transitions. We show that, under certain conditions, the use of this parameter for the analysis of unfolding transitions leads to the incorrect determination of thermodynamic parameters characterizing unfolding transitions in proteins (e.g., melting temperature) and, hence, can compromise the hit identification during high-throughput drug screening campaigns. © 2017 The Protein Society.

  15. Real-time holographic deconvolution techniques for one-way image transmission through an aberrating medium: characterization, modeling, and measurements.

    PubMed

    Haji-Saeed, B; Sengupta, S K; Testorf, M; Goodhue, W; Khoury, J; Woods, C L; Kierstead, J

    2006-05-10

    We propose and demonstrate a new photorefractive real-time holographic deconvolution technique for adaptive one-way image transmission through aberrating media by means of four-wave mixing. In contrast with earlier methods, which typically required various codings of the exact phase or two-way image transmission for correcting phase distortion, our technique relies on one-way image transmission through the use of exact phase information. Our technique can simultaneously correct both amplitude and phase distortions. We include several forms of image degradation, various test cases, and experimental results. We characterize the performance as a function of the input beam ratios for four metrics: signal-to-noise ratio, normalized root-mean-square error, edge restoration, and peak-to-total energy ratio. In our characterization we use false-color graphic images to display the best beam-intensity ratio two-dimensional region(s) for each of these metrics. Test cases are simulated at the optimal values of the beam-intensity ratios. We demonstrate our results through both experiment and computer simulation.

  16. Stress Intensity Factors for Part-Through Surface Cracks in Hollow Cylinders

    NASA Technical Reports Server (NTRS)

    Mettu, Sambi R.; Raju, Ivatury S.; Forman, Royce G.

    1992-01-01

    Flaws resulting from improper welding and forging are usually modeled as cracks in flat plates, hollow cylinders or spheres. The stress intensity factor solutions for these crack cases are of great practical interest. This report describes some recent efforts at improving the stress intensity factor solutions for cracks in such geometries with emphasis on hollow cylinders. Specifically, two crack configurations for cylinders are documented. One is that of a surface crack in an axial plane and the other is a part-through thumb-nail crack in a circumferential plane. The case of a part-through surface crack in flat plates is used as a limiting case for very thin cylinders. A combination of the two cases for cylinders is used to derive a relation for the case of a surface crack in a sphere. Solutions were sought which cover the entire range of the geometrical parameters such as cylinder thickness, crack aspect ratio and crack depth. Both the internal and external position of the cracks are considered for cylinders and spheres. The finite element method was employed to obtain the basic solutions. Power-law form of loading was applied in the case of flat plates and axial cracks in cylinders and uniform tension and bending loads were applied in the case of circumferential (thumb-nail) cracks in cylinders. In the case of axial cracks, the results for tensile and bending loads were used as reference solutions in a weight function scheme so that the stress intensity factors could be computed for arbitrary stress gradients in the thickness direction. For circumferential cracks, since the crack front is not straight, the above technique could not be used. Hence for this case, only the tension and bending solutions are available at this time. The stress intensity factors from the finite element method were tabulated so that results for various geometric parameters such as crack depth-to-thickness ratio (a/t), crack aspect ratio (a/c) and internal radius-to-thickness ratio (R/t) or the crack length-to-width ratio (2c/W) could be obtained by interpolation and extrapolation. Such complete tables were then incorporated into the NASA/FLAGRO computer program which is widely used by the aerospace community for fracture mechanics analysis.

  17. Analysis of root surface properties by fluorescence/Raman intensity ratio.

    PubMed

    Nakamura, Shino; Ando, Masahiro; Hamaguchi, Hiro-O; Yamamoto, Matsuo

    2017-11-01

    The aim of this study is to evaluate the existence of residual calculus on root surfaces by determining the fluorescence/Raman intensity ratio. Thirty-two extracted human teeth, partially covered with calculus on the root surface, were evaluated by using a portable Raman spectrophotometer, and a 785-nm, 100-mW laser was applied for fluorescence/Raman excitation. The collected spectra were normalized to the hydroxyapatite Raman band intensity at 960 cm -1 . Raman spectra were recorded from the same point after changing the focal distance of the laser and the target radiating angle. In seven teeth, the condition of calculus, cementum, and dentin were evaluated. In 25 teeth, we determined the fluorescence/Raman intensity ratio following three strokes of debridement. Raman spectra collected from the dentin, cementum, and calculus were different. After normalization, spectra values were constant. The fluorescence/Raman intensity ratio of calculus region showed significant differences compared to the cementum and dentin (p < 0.05). The fluorescence/Raman intensity ratio decreased with calculus debridement. For this analysis, the delta value was defined as the difference between the values before and after three strokes, with the final 2 delta values close to zero, indicating a gradual asymptotic curve and the change in intensity ratio approximating that of individual constants. Fluorescence/Raman intensity ratio was effectively used to cancel the angle- and distance-dependent fluctuations of fluorescence collection efficiency during measurement. Changes in the fluorescence/Raman intensity ratio near zero suggested that cementum or dentin was exposed, and calculus removed.

  18. Measurement of Insertion Loss of an Acoustic Treatment in the Presence of Additional Uncorrelated Sound Sources

    NASA Technical Reports Server (NTRS)

    Klos, Jacob; Palumbo, Daniel L.

    2003-01-01

    A method to intended for measurement of the insertion loss of an acoustic treatment applied to an aircraft fuselage in-situ is documented in this paper. Using this method, the performance of a treatment applied to a limited portion of an aircraft fuselage can be assessed even though the untreated fuselage also radiates into the cabin, corrupting the intensity measurement. This corrupting noise in the intensity measurement incoherent with the panel vibration of interest is removed by correlating the intensity to reference transducers such as accelerometers. Insertion loss of the acoustic treatments is estimated from the ratio of correlated intensity measurements with and without a treatment applied. In the case of turbulent boundary layer excitation of the fuselage, this technique can be used to assess the performance of noise control methods without requiring treatment of the entire fuselage. Several experimental studies and numerical simulations have been conducted, and results from three case studies are documented in this paper. Conclusions are drawn about the use of this method to study aircraft sidewall treatments.

  19. Three-dimensional analysis of chevron-notched specimens by boundary integral method

    NASA Technical Reports Server (NTRS)

    Mendelson, A.; Ghosn, L.

    1983-01-01

    The chevron-notched short bar and short rod specimens was analyzed by the boundary integral equations method. This method makes use of boundary surface elements in obtaining the solution. The boundary integral models were composed of linear triangular and rectangular surface segments. Results were obtained for two specimens with width to thickness ratios of 1.45 and 2.00 and for different crack length to width ratios ranging from 0.4 to 0.7. Crack opening displacement and stress intensity factors determined from displacement calculations along the crack front and compliance calculations were compared with experimental values and with finite element analysis.

  20. Quantification of the fraction poorly deformable red blood cells using ektacytometry.

    PubMed

    Streekstra, G J; Dobbe, J G G; Hoekstra, A G

    2010-06-21

    We describe a method to obtain the fraction of poorly deformable red blood cells in a blood sample from the intensity pattern in an ektacytometer. In an ektacytometer red blood cells are transformed into ellipsoids by a shear flow between two transparent cylinders. The intensity pattern, due to a laser beam that is sent through the suspension, is projected on a screen. When measuring a healthy red blood cell population iso-intensity curves are ellipses with an axial ratio equal to that of the average red blood cell. In contrast poorly deformable cells result in circular iso-intensity curves. In this study we show that for mixtures of deformable and poorly deformable red blood cells, iso-intensity curves in the composite intensity pattern are neither elliptical nor circular but obtain cross-like shapes. We propose a method to obtain the fraction of poorly deformable red blood cells from those intensity patterns. Experiments with mixtures of poorly deformable and deformable red blood cells validate the method and demonstrate its accuracy. In a clinical setting our approach is potentially of great value for the detection of the fraction of sickle cells in blood samples of patients with sickle cell disease or to find a measure for the parasitemia in patients infected with malaria.

  1. Quantifying the statistical importance of utilizing regression over classic energy intensity calculations for tracking efficiency improvements in industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nimbalkar, Sachin U.; Wenning, Thomas J.; Guo, Wei

    In the United States, manufacturing facilities account for about 32% of total domestic energy consumption in 2014. Robust energy tracking methodologies are critical to understanding energy performance in manufacturing facilities. Due to its simplicity and intuitiveness, the classic energy intensity method (i.e. the ratio of total energy use over total production) is the most widely adopted. However, the classic energy intensity method does not take into account the variation of other relevant parameters (i.e. product type, feed stock type, weather, etc.). Furthermore, the energy intensity method assumes that the facilities’ base energy consumption (energy use at zero production) is zero,more » which rarely holds true. Therefore, it is commonly recommended to utilize regression models rather than the energy intensity approach for tracking improvements at the facility level. Unfortunately, many energy managers have difficulties understanding why regression models are statistically better than utilizing the classic energy intensity method. While anecdotes and qualitative information may convince some, many have major reservations about the accuracy of regression models and whether it is worth the time and effort to gather data and build quality regression models. This paper will explain why regression models are theoretically and quantitatively more accurate for tracking energy performance improvements. Based on the analysis of data from 114 manufacturing plants over 12 years, this paper will present quantitative results on the importance of utilizing regression models over the energy intensity methodology. This paper will also document scenarios where regression models do not have significant relevance over the energy intensity method.« less

  2. Improvements to the modal holographic wavefront sensor.

    PubMed

    Kong, Fanpeng; Lambert, Andrew

    2016-05-01

    The Zernike coefficients of a light wavefront can be calculated directly by intensity ratios of pairs of spots in the reconstructed image plane of a holographic wavefront sensor (HWFS). However, the response curve of the HWFS heavily depends on the position and size of the detector for each spot and the distortions introduced by other aberrations. In this paper, we propose a method to measure the intensity of each spot by setting a threshold to select effective pixels and using the weighted average intensity within a selected window. Compared with using the integral intensity over a small window for each spot, we show through a numerical simulation that the proposed method reduces the dependency of the HWFS's response curve on the selection of the detector window. We also recorded a HWFS on a holographic plate using a blue laser and demonstrated its capability to detect the strength of encoded Zernike terms in an aberrated beam.

  3. Paper area density measurement from forward transmitted scattered light

    DOEpatents

    Koo, Jackson C.

    2001-01-01

    A method whereby the average paper fiber area density (weight per unit area) can be directly calculated from the intensity of transmitted, scattered light at two different wavelengths, one being a non-absorpted wavelength. Also, the method makes it possible to derive the water percentage per fiber area density from a two-wavelength measurement. In the optical measuring technique optical transmitted intensity, for example, at 2.1 microns cellulose absorption line is measured and compared with another scattered, optical transmitted intensity reference in the nearby spectrum region, such as 1.68 microns, where there is no absorption. From the ratio of these two intensities, one can calculate the scattering absorption coefficient at 2.1 microns. This absorption coefficient at this wavelength is, then, experimentally correlated to the paper fiber area density. The water percentage per fiber area density can be derived from this two-wavelength measurement approach.

  4. Determination of cellulose I crystallinity by FT-Raman spectroscopy

    Treesearch

    Umesh P. Agarwal; Richard S. Reiner; Sally A. Ralph

    2009-01-01

    Two new methods based on FT-Raman spectroscopy, one simple, based on band intensity ratio, and the other, using a partial least-squares (PLS) regression model, are proposed to determine cellulose I crystallinity. In the simple method, crystallinity in semicrystalline cellulose I samples was determined based on univariate regression that was first developed using the...

  5. Optimum Material Composition for Minimizing the Stress Intensity Factor of Edge Crack in Thick-Walled FGM Circular Pipes Under Thermomechanical Loading

    NASA Astrophysics Data System (ADS)

    Sekine, Hideki; Yoshida, Kimiaki

    This paper deals with the optimization problem of material composition for minimizing the stress intensity factor of radial edge crack in thick-walled functionally graded material (FGM) circular pipes under steady-state thermomechanical loading. Homogenizing the FGM circular pipes by simulating the inhomogeneity of thermal conductivity by a distribution of equivalent eigentemperature gradient and the inhomogeneity of Young's modulus and Poisson's ratio by a distribution of equivalent eigenstrain, we present an approximation method to obtain the stress intensity factor of radial edge crack in the FGM circular pipes. The optimum material composition for minimizing the stress intensity factor of radial edge crack is determined using a nonlinear mathematical programming method. Numerical results obtained for a thick-walled TiC/Al2O3 FGM circular pipe reveal that it is possible to decrease remarkably the stress intensity factor of radial edge crack by setting the optimum material composition profile.

  6. X-ray luminescence computed tomography imaging via multiple intensity weighted narrow beam irradiation

    NASA Astrophysics Data System (ADS)

    Feng, Bo; Gao, Feng; Zhao, Huijuan; Zhang, Limin; Li, Jiao; Zhou, Zhongxing

    2018-02-01

    The purpose of this work is to introduce and study a novel x-ray beam irradiation pattern for X-ray Luminescence Computed Tomography (XLCT), termed multiple intensity-weighted narrow-beam irradiation. The proposed XLCT imaging method is studied through simulations of x-ray and diffuse lights propagation. The emitted optical photons from X-ray excitable nanophosphors were collected by optical fiber bundles from the right-side surface of the phantom. The implementation of image reconstruction is based on the simulated measurements from 6 or 12 angular projections in terms of 3 or 5 x-ray beams scanning mode. The proposed XLCT imaging method is compared against the constant intensity weighted narrow-beam XLCT. From the reconstructed XLCT images, we found that the Dice similarity and quantitative ratio of targets have a certain degree of improvement. The results demonstrated that the proposed method can offer simultaneously high image quality and fast image acquisition.

  7. Benchmarking to Identify Practice Variation in Test Ordering: A Potential Tool for Utilization Management.

    PubMed

    Signorelli, Heather; Straseski, Joely A; Genzen, Jonathan R; Walker, Brandon S; Jackson, Brian R; Schmidt, Robert L

    2015-01-01

    Appropriate test utilization is usually evaluated by adherence to published guidelines. In many cases, medical guidelines are not available. Benchmarking has been proposed as a method to identify practice variations that may represent inappropriate testing. This study investigated the use of benchmarking to identify sites with inappropriate utilization of testing for a particular analyte. We used a Web-based survey to compare 2 measures of vitamin D utilization: overall testing intensity (ratio of total vitamin D orders to blood-count orders) and relative testing intensity (ratio of 1,25(OH)2D to 25(OH)D test orders). A total of 81 facilities contributed data. The average overall testing intensity index was 0.165, or approximately 1 vitamin D test for every 6 blood-count tests. The average relative testing intensity index was 0.055, or one 1,25(OH)2D test for every 18 of the 25(OH)D tests. Both indexes varied considerably. Benchmarking can be used as a screening tool to identify outliers that may be associated with inappropriate test utilization. Copyright© by the American Society for Clinical Pathology (ASCP).

  8. First measurement of electron temperature from signal ratios in a double-pass Thomson scattering system.

    PubMed

    Tojo, H; Ejiri, A; Hiratsuka, J; Yamaguchi, T; Takase, Y; Itami, K; Hatae, T

    2012-02-01

    This paper presents an experimental demonstration to determine electron temperature (T(e)) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T(e) can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T(e) measured from the ratio (T(e,r)) and T(e) measured from a standard method (T(e,s)) showed a good agreement with <∣T(e,r) - T(e,s)∣∕T(e,s)> = 7.3%.

  9. Method of determining the optimal dilution ratio for fluorescence fingerprint of food constituents.

    PubMed

    Trivittayasil, Vipavee; Tsuta, Mizuki; Kokawa, Mito; Yoshimura, Masatoshi; Sugiyama, Junichi; Fujita, Kaori; Shibata, Mario

    2015-01-01

    Quantitative determination by fluorescence spectroscopy is possible because of the linear relationship between the intensity of emitted fluorescence and the fluorophore concentration. However, concentration quenching may cause the relationship to become nonlinear, and thus, the optimal dilution ratio has to be determined. In the case of fluorescence fingerprint (FF) measurement, fluorescence is measured under multiple wavelength conditions and a method of determining the optimal dilution ratio for multivariate data such as FFs has not been reported. In this study, the FFs of mixed solutions of tryptophan and epicatechin of different concentrations and composition ratios were measured. Principal component analysis was applied, and the resulting loading plots were found to contain useful information about each constituent. The optimal concentration ranges could be determined by identifying the linear region of the PC score plotted against total concentration.

  10. Biomass production on the Olympic and Kitsap Peninsulas, Washington: updated logging residue ratios, slash pile volume-to-weight ratios, and supply curves for selected locations

    Treesearch

    Jason C. Cross; Eric C. Turnblom; Gregory J. Ettl

    2013-01-01

    Biomass residue produced by timber harvest operations is estimated for the Olympic and Kitsap Peninsulas, Washington. Scattered residues were sampled in 53 harvest units and piled residues were completely enumerated in 55 harvest units. Production is based on 2008 and 2009 data and is stratified by forest location, ownership type, harvest intensity, and harvest method...

  11. Electron-correlation effects on the 3 C to 3 D line-intensity ratio in the Ne-like ions Ar 8 + to Kr 26 +

    DOE PAGES

    Santana, Juan A.; Lepson, Jaan K.; Trabert, Elmar; ...

    2015-01-07

    We present a theoretical and experimental investigation of the 3d→2p resonance to the intercombination line ratio in low- to mid-Z neonlike ions of astrophysical interest, i.e., of the 2p 1/22p 4 3/23d 3/2 1P o 1 → 2p 6 1S 0 and 2p 2 1/22p 3 3/23d 5/2 3D o 1 → 2p 6 1S 0 transitions commonly labeled 3C and 3D, respectively. In particular, we have employed the configuration-interaction method with three different numbers of basis states and the many-body perturbation theory method to calculate oscillator strengths and energies for neonlike ions from Z = 18 to 36. Combiningmore » our calculations with a systematic study of previous works in the literature, we show that these methods can predict accurate and converged energies for these transitions. We also find convergence for the oscillator strengths, but the ratio of oscillator strengths, which can be compared to experimental values of the relative intensity ratios of these lines, appears to converge to values higher than measured. We speculate that this is due to the role of electron-electron correlations. While the amount of electron correlations associated with the intercombination line 3D appears to be well described, it seems that the contributions from highly excited states are not sufficiently accounted for in the case of the resonance line 3C. In order to augment the body of available experimental data for neonlike ions, we present a measurement of the 3C and 3D lines in neonlike Ar 8+. We report a wavelength of 41.480±0.001 Å for line 3C and 42.005±0.001 Å for line 3D. Lastly, the intensity ratio of the two lines was determined to be I(3C)/I(3D)=11.32±1.40.« less

  12. Calibration and assessment of channel-specific biases in microarray data with extended dynamical range.

    PubMed

    Bengtsson, Henrik; Jönsson, Göran; Vallon-Christersson, Johan

    2004-11-12

    Non-linearities in observed log-ratios of gene expressions, also known as intensity dependent log-ratios, can often be accounted for by global biases in the two channels being compared. Any step in a microarray process may introduce such offsets and in this article we study the biases introduced by the microarray scanner and the image analysis software. By scanning the same spotted oligonucleotide microarray at different photomultiplier tube (PMT) gains, we have identified a channel-specific bias present in two-channel microarray data. For the scanners analyzed it was in the range of 15-25 (out of 65,535). The observed bias was very stable between subsequent scans of the same array although the PMT gain was greatly adjusted. This indicates that the bias does not originate from a step preceding the scanner detector parts. The bias varies slightly between arrays. When comparing estimates based on data from the same array, but from different scanners, we have found that different scanners introduce different amounts of bias. So do various image analysis methods. We propose a scanning protocol and a constrained affine model that allows us to identify and estimate the bias in each channel. Backward transformation removes the bias and brings the channels to the same scale. The result is that systematic effects such as intensity dependent log-ratios are removed, but also that signal densities become much more similar. The average scan, which has a larger dynamical range and greater signal-to-noise ratio than individual scans, can then be obtained. The study shows that microarray scanners may introduce a significant bias in each channel. Such biases have to be calibrated for, otherwise systematic effects such as intensity dependent log-ratios will be observed. The proposed scanning protocol and calibration method is simple to use and is useful for evaluating scanner biases or for obtaining calibrated measurements with extended dynamical range and better precision. The cross-platform R package aroma, which implements all described methods, is available for free from http://www.maths.lth.se/bioinformatics/.

  13. Change detection for synthetic aperture radar images based on pattern and intensity distinctiveness analysis

    NASA Astrophysics Data System (ADS)

    Wang, Xiao; Gao, Feng; Dong, Junyu; Qi, Qiang

    2018-04-01

    Synthetic aperture radar (SAR) image is independent on atmospheric conditions, and it is the ideal image source for change detection. Existing methods directly analysis all the regions in the speckle noise contaminated difference image. The performance of these methods is easily affected by small noisy regions. In this paper, we proposed a novel change detection framework for saliency-guided change detection based on pattern and intensity distinctiveness analysis. The saliency analysis step can remove small noisy regions, and therefore makes the proposed method more robust to the speckle noise. In the proposed method, the log-ratio operator is first utilized to obtain a difference image (DI). Then, the saliency detection method based on pattern and intensity distinctiveness analysis is utilized to obtain the changed region candidates. Finally, principal component analysis and k-means clustering are employed to analysis pixels in the changed region candidates. Thus, the final change map can be obtained by classifying these pixels into changed or unchanged class. The experiment results on two real SAR images datasets have demonstrated the effectiveness of the proposed method.

  14. Biological tissue component evaluation by measuring photoacoustic spectrum

    NASA Astrophysics Data System (ADS)

    Namita, Takeshi; Murata, Yuya; Tokuyama, Junji; Kondo, Kengo; Yamakawa, Makoto; Shiina, Tsuyoshi

    2017-03-01

    Photoacoustic imaging has garnered constant attention as a non-invasive modality for visualizing details of the neovascularization structure of tumors, or the distribution of oxygen saturation, which is related to the tumor grade. However, photoacoustic imaging is applicable not only for vascular imaging but also for diagnosing properties of various tissues such as skin or muscle diseases, fat related to arteriosclerosis or fatty liver, cartilage related to arthritis, and fibrous tissues related to hepatitis. The photoacoustic signal intensity is wavelength-dependent and proportional to the absorption coefficient and thermal acoustic conversion efficiency (i.e. Grüneisen parameter) of the target biological tissue. To ascertain the appropriate wavelength range for biological tissue imaging and to evaluate tissue properties, photoacoustic spectra of various tissues (e.g., skin, muscle, and adipose tissue) were measured using a hydrophone (9 mm diameter) at 680-1600 nm wavelengths. Results confirmed that respective tissues have unique photoacoustic spectra. However, almost all samples have peaks around 1200 nm and 1400-1500 nm for wavelengths where the light absorbance of lipid or water is high. The main components of biological tissues are water, protein, and lipid. Results confirmed that photoacoustic spectra reflect the tissue components well. To evaluate the feasibility of the tissue characterization using photoacoustic methods, the photoacoustic signal intensity ratio between two wavelength regions was calculated as described above. Signal intensity ratios agreed well with the composition ratio between water and lipid in samples. These analyses verified the feasibility of evaluating tissue properties using photoacoustic methods.

  15. Amplitude-phase cross talk as a deterioration factor of signal-to-noise ratio in phase-detection noise-cancellation technique for spectral pump/probe measurements and compensation of the amplitude-phase cross talk

    NASA Astrophysics Data System (ADS)

    Seto, Keisuke; Tarumi, Takashi; Tokunaga, Eiji

    2018-06-01

    Noise cancellation of the light source is an important method to enhance the signal-to-noise ratio (SNR) and facilitate high-speed detection in pump/probe measurements. We developed a method to eliminate the noise for the multichannel spectral pump/probe measurements with a spectral dispersion of a white probe pulse light. In this method, the sample-induced intensity modulation is converted to the phase modulation of the pulse repetition irrespective of the intensity noise of the light source. The SNR is enhanced through the phase detection of the observed signal with the signal synchronized to the pulse repetition serving as the phase reference (synchronized signal). However, the shot-noise limited performance is not achieved with an intense probe light. In this work, we demonstrate that the performance limitation below the shot noise limit is caused by the amplitude-phase cross talk. It converts the amplitude noise into the phase noise and is caused by the space-charge effect in the photodetector, the reverse bias voltage drop across the load impedance, and the phase detection circuit. The phase delay occurs with an intense light at a PIN photodiode, whereas the phase is advanced in an avalanche photodiode. Although the amplitude distortion characteristics also reduce the performance, the distortion effect is equivalent to the amplitude-phase cross talk. We also propose possible ways to compensate the cross talk effect by using the phase modulation of the synchronized signal for the phase detection based on the instantaneous amplitude.

  16. A Comparative Assessment of Track Plates to Quantify Fine Scale Variations in the Relative Abundance of Norway Rats in Urban Slums

    PubMed Central

    Begon, Mike; Diggle, Peter J.; Serrano, Soledad; Reis, Mitermayer G.; Childs, James E.; Ko, Albert I.; Costa, Federico

    2016-01-01

    Norway rats (Rattus norvegicus) living in urban environments are a critical public health and economic problem, particularly in urban slums where residents are at a higher risk for rat borne diseases, yet convenient methods to quantitatively assess population sizes are lacking. We evaluated track plates as a method to determine rat distribution and relative abundance in a complex urban slum environment by correlating the presence and intensity of rat-specific marks on track plates with findings from rat infestation surveys and trapping of rats to population exhaustion. To integrate the zero-inflated track plate data we developed a two-component mixture model with one binary and one censored continuous component. Track plate mark-intensity was highly correlated with signs of rodent infestation (all coefficients between 0.61 and 0.79 and all p-values < 0.05). Moreover, the mean level of pre-trapping rat-mark intensity on plates was significantly associated with the number of rats captured subsequently (Odds ratio1.38; 95% CI 1.19-1.61) and declined significantly following trapping (Odds ratio 0.86; 95% CI 0.78-0.95). Track plates provided robust proxy measurements of rat abundance and distribution and detected rat presence even when populations appeared ‘trapped out’. Tracking plates are relatively easy and inexpensive methods that can be used to intensively sample settings such as urban slums, where traditional trapping or mark-recapture studies are impossible to implement, and therefore the results can inform and assess the impact of targeted urban rodent control campaigns. PMID:27453682

  17. Centric scan SPRITE for spin density imaging of short relaxation time porous materials.

    PubMed

    Chen, Quan; Halse, Meghan; Balcom, Bruce J

    2005-02-01

    The single-point ramped imaging with T1 enhancement (SPRITE) imaging technique has proven to be a very robust and flexible method for the study of a wide range of systems with short signal lifetimes. As a pure phase encoding technique, SPRITE is largely immune to image distortions generated by susceptibility variations, chemical shift and paramagnetic impurities. In addition, it avoids the line width restrictions on resolution common to time-based sampling, frequency encoding methods. The standard SPRITE technique is however a longitudinal steady-state imaging method; the image intensity is related to the longitudinal steady state, which not only decreases the signal-to-noise ratio, but also introduces many parameters into the image signal equation. A centric scan strategy for SPRITE removes the longitudinal steady state from the image intensity equation and increases the inherent image intensity. Two centric scan SPRITE methods, that is, Spiral-SPRITE and Conical-SPRITE, with fast acquisition and greatly reduced gradient duty cycle, are outlined. Multiple free induction decay (FID) points may be acquired during SPRITE sampling for signal averaging to increase signal-to-noise ratio or for T2* and spin density mapping without an increase in acquisition time. Experimental results show that most porous sedimentary rock and concrete samples have a single exponential T2* decay due to susceptibility difference-induced field distortion. Inhomogeneous broadening thus dominates, which suggests that spin density imaging can be easily obtained by SPRITE.

  18. Synaptic dynamics regulation in response to high frequency stimulation in neuronal networks

    NASA Astrophysics Data System (ADS)

    Su, Fei; Wang, Jiang; Li, Huiyan; Wei, Xile; Yu, Haitao; Deng, Bin

    2018-02-01

    High frequency stimulation (HFS) has confirmed its ability in modulating the pathological neural activities. However its detailed mechanism is unclear. This study aims to explore the effects of HFS on neuronal networks dynamics. First, the two-neuron FitzHugh-Nagumo (FHN) networks with static coupling strength and the small-world FHN networks with spike-time-dependent plasticity (STDP) modulated synaptic coupling strength are constructed. Then, the multi-scale method is used to transform the network models into equivalent averaged models, where the HFS intensity is modeled as the ratio between stimulation amplitude and frequency. Results show that in static two-neuron networks, there is still synaptic current projected to the postsynaptic neuron even if the presynaptic neuron is blocked by the HFS. In the small-world networks, the effects of the STDP adjusting rate parameter on the inactivation ratio and synchrony degree increase with the increase of HFS intensity. However, only when the HFS intensity becomes very large can the STDP time window parameter affect the inactivation ratio and synchrony index. Both simulation and numerical analysis demonstrate that the effects of HFS on neuronal network dynamics are realized through the adjustment of synaptic variable and conductance.

  19. Optical diagnostics with radiation trapping effect in low density and low temperature helium plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Wonwook, E-mail: wwlee@kaeri.re.kr; Kwon, Duck-Hee; Park, Kyungdeuk

    2016-06-15

    Low density (n{sub e} < 10{sup 11 }cm{sup −3}) and low temperature (T{sub e} < 10 eV) helium plasma was generated by hot filament discharge. Electron temperature and density of neutral helium plasma were measured by Langmuir probe and were determined by line intensity ratio method using optical emission spectroscopy with population modelings. Simple corona model and collisional-radiative (CR) model without consideration for radiation trapping effect are applied. In addition, CR model taking into account the radiation trapping effect (RTE) is adopted. The change of single line intensity ratio as a function of electron temperature and density were investigated when the RTE is included and excluded.more » The changes of multi line intensity ratios as a function of electron temperature were scanned for various radiative-excitation rate coefficients from the ground state and the helium gas pressures related with the RTE. Our CR modeling with RTE results in fairly better agreement of the spectroscopic diagnostics for the plasma temperature or density with the Langmuir probe measurements for various helium gas pressures than corona modeling and CR modeling without RTE.« less

  20. Effect of external turbulence on the efficiency of film cooling with coolant injection into a transverse trench

    NASA Astrophysics Data System (ADS)

    Khalatov, A. A.; Panchenko, N. A.; Severin, S. D.

    2017-09-01

    Film cooling is among the basic methods used for thermal protection of blades in modern high-temperature gas turbines. Results of computer simulation of film cooling with coolant injection via a row of conventional inclined holes or a row of holes in a trench are presented in this paper. The ANSYS CFX 14 commercial software package was used for CFD-modeling. The effect is studied of the mainstream turbulence on the film cooling efficiency for the blowing ratio range between 0.6 and 2.3 and three different turbulence intensities of 1, 5, and 10%. The mainstream velocity was 150 and 400 m/s, while the temperatures of the mainstream and the injected coolant were 1100 and 500°C, respectively. It is demonstrated that, for the coolant injection via one row of trenched holes, an increase in the mainstream turbulence intensity reduces the film cooling efficiency in the entire investigated range of blowing ratios. It was revealed that freestream turbulence had varied effects on the film cooling efficiency depending on the blowing ratio and mainstream velocity in a blade channel. Thus, an increase in the mainstream turbulence intensity from 1 to 10% decreases the surface-averaged film cooling efficiency by 3-10% at a high mainstream velocity (400 m/s) in the blade channel and by 12-23% at a moderate velocity (of 150 m/s). Here, lower film cooling efficiencies correspond to higher blowing ratios. The effect of mainstream turbulence intensity on the film cooling efficiency decreases with increasing the mainstream velocity in the modeled channel for both investigated configurations.

  1. Adaptive channel estimation for soft decision decoding over non-Gaussian optical channel

    NASA Astrophysics Data System (ADS)

    Xiang, Jing-song; Miao, Tao-tao; Huang, Sheng; Liu, Huan-lin

    2016-10-01

    An adaptive priori likelihood ratio (LLR) estimation method is proposed over non-Gaussian channel in the intensity modulation/direct detection (IM/DD) optical communication systems. Using the nonparametric histogram and the weighted least square linear fitting in the tail regions, the LLR is estimated and used for the soft decision decoding of the low-density parity-check (LDPC) codes. This method can adapt well to the three main kinds of intensity modulation/direct detection (IM/DD) optical channel, i.e., the chi-square channel, the Webb-Gaussian channel and the additive white Gaussian noise (AWGN) channel. The performance penalty of channel estimation is neglected.

  2. A Passive Method for Detecting Vegetation Stress from Orbit: Chlorophyll Fluorescence Spectra from Fraunhofer Lines

    NASA Technical Reports Server (NTRS)

    Theisen, Arnold F.

    2000-01-01

    Solar-stimulated chlorophyll fluorescence measured with the Fraunhofer line depth method has correlated well with vegetation stress in previous studies. However, the instruments used in those studies were limited to a single solar absorption line (e.g. 656.3 nm), obviating the red/far-red ratio (R/FR) method. Optics and detector technology have reached the level whereby multiple, very narrow Fraunhofer lines are resolvable. Thirteen such lines span the visible spectrum in the red to far-red region where chlorophyll fluorescence occurs. Fluorescence intensities at the 13 Fraunhofer line wavelengths were used to model emission spectra. The source data were collected for summer and fall bean crops (Phaseolus vulgaris L.) subjected to various levels of nitrogen fertilization. The intensities were adjusted to account for Fraunhofer line depth and atmospheric transmittance. Multiple R/FR fluorescence ratios, calculated from the modeled fluorescence spectra, correlated strongly with leaf chlorophyll concentration and well with applied nitrogen. The ratio yielding the best correlation with chlorophyll utilized red fluorescence at the 694.5 nm Fraunhofer line and farred fluorescence at the 755.6 nm Fraunhofer line. Twenty R/FR ratios, each evaluated for the maximum differential between low and high (optimal) nitrogen treatments, ranked higher in some cases and lower in others, possibly related to the time of year the crops were grown and the stage of growth of the crops. Ratios with 728.9 nm and 738.9 nm in the denominator consistently ranked in the lowest and next lowest quartile, respectively. Ratios of the 656.3 nm Fraunhofer line and the 755.6 nm line consistently ranked highest for the summer crop. Ratios with 755.6 nm in the denominator ranked in the upper quartile for 10 out of 12 measurement dates. Differences in ratio ranking indicate that physiological conditions may be estimated using selected ratios of Fraunhofer lines within the context of R/FR analysis. A passive instrument designed to monitor R/FR chlorophyll fluorescence (i.e. vegetation stress) from orbit could be built today.

  3. Model-independent Exoplanet Transit Spectroscopy

    NASA Astrophysics Data System (ADS)

    Aronson, Erik; Piskunov, Nikolai

    2018-05-01

    We propose a new data analysis method for obtaining transmission spectra of exoplanet atmospheres and brightness variation across the stellar disk from transit observations. The new method is capable of recovering exoplanet atmosphere absorption spectra and stellar specific intensities without relying on theoretical models of stars and planets. We simultaneously fit both stellar specific intensity and planetary radius directly to transit light curves. This allows stellar models to be removed from the data analysis. Furthermore, we use a data quality weighted filtering technique to achieve an optimal trade-off between spectral resolution and reconstruction fidelity homogenizing the signal-to-noise ratio across the wavelength range. Such an approach is more efficient than conventional data binning onto a low-resolution wavelength grid. We demonstrate that our analysis is capable of reproducing results achieved by using an explicit quadratic limb-darkening equation and that the filtering technique helps eliminate spurious spectral features in regions with strong telluric absorption. The method is applied to the VLT FORS2 observations of the exoplanets GJ 1214 b and WASP-49 b, and our results are in agreement with previous studies. Comparisons between obtained stellar specific intensity and numerical models indicates that the method is capable of accurately reconstructing the specific intensity. The proposed method enables more robust characterization of exoplanetary atmospheres by separating derivation of planetary transmission and stellar specific intensity spectra (that is model-independent) from chemical and physical interpretation.

  4. Chemiluminescence-based multivariate sensing of local equivalence ratios in premixed atmospheric methane-air flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tripathi, Markandey M.; Krishnan, Sundar R.; Srinivasan, Kalyan K.

    Chemiluminescence emissions from OH*, CH*, C2, and CO2 formed within the reaction zone of premixed flames depend upon the fuel-air equivalence ratio in the burning mixture. In the present paper, a new partial least square regression (PLS-R) based multivariate sensing methodology is investigated and compared with an OH*/CH* intensity ratio-based calibration model for sensing equivalence ratio in atmospheric methane-air premixed flames. Five replications of spectral data at nine different equivalence ratios ranging from 0.73 to 1.48 were used in the calibration of both models. During model development, the PLS-R model was initially validated with the calibration data set using themore » leave-one-out cross validation technique. Since the PLS-R model used the entire raw spectral intensities, it did not need the nonlinear background subtraction of CO2 emission that is required for typical OH*/CH* intensity ratio calibrations. An unbiased spectral data set (not used in the PLS-R model development), for 28 different equivalence ratio conditions ranging from 0.71 to 1.67, was used to predict equivalence ratios using the PLS-R and the intensity ratio calibration models. It was found that the equivalence ratios predicted with the PLS-R based multivariate calibration model matched the experimentally measured equivalence ratios within 7%; whereas, the OH*/CH* intensity ratio calibration grossly underpredicted equivalence ratios in comparison to measured equivalence ratios, especially under rich conditions ( > 1.2). The practical implications of the chemiluminescence-based multivariate equivalence ratio sensing methodology are also discussed.« less

  5. [Spectral investigation of atmospheric pressure plasma column].

    PubMed

    Li, Xue-Chen; Chang, Yuan-Yuan; Xu, Long-Fei

    2012-07-01

    Atmospheric pressure plasma column has many important applications in plasma stealth for aircraft. In the present paper, a plasma column with a length of 65 cm was generated in argon at atmospheric pressure by using dielectric barrier discharge device with water electrodes in coaxial configurations. The discharge mechanism of the plasma column was studied by optical method and the result indicates that a moving layer of light emission propagates in the upstream region. The propagation velocity of the plasma bullet is about 0.6 x 10(5) m x s(-1) through optical measurement. Spectral intensity ratios as functions of the applied voltage and driving frequency were also investigated by spectroscopic method. The variation in spectral intensity ratio implies a change in the averaged electron energy. Results show that the averaged electron energy increases with the increase in the applied voltage and the driving frequency. These results have significant values for industrial applications of the atmospheric pressure discharge and have extensive application potentials in stealth for military aircraft.

  6. The stress intensity factors for a periodic array of interacting coplanar penny-shaped cracks

    PubMed Central

    Lekesiz, Huseyin; Katsube, Noriko; Rokhlin, Stanislav I.; Seghi, Robert R.

    2013-01-01

    The effect of crack interactions on stress intensity factors is examined for a periodic array of coplanar penny-shaped cracks. Kachanov’s approximate method for crack interactions (Int. J. Solid. Struct. 1987; 23(1):23–43) is employed to analyze both hexagonal and square crack configurations. In approximating crack interactions, the solution converges when the total truncation number of the cracks is 109. As expected, due to high density packing crack interaction in the hexagonal configuration is stronger than that in the square configuration. Based on the numerical results, convenient fitting equations for quick evaluation of the mode I stress intensity factors are obtained as a function of crack density and angle around the crack edge for both crack configurations. Numerical results for the mode II and III stress intensity factors are presented in the form of contour lines for the case of Poisson’s ratio ν =0.3. Possible errors for these problems due to Kachanov’s approximate method are estimated. Good agreement is observed with the limited number of results available in the literature and obtained by different methods. PMID:27175035

  7. Hybrid phosphorescence and fluorescence native spectroscopy for breast cancer detection.

    PubMed

    Alimova, Alexandra; Katz, A; Sriramoju, Vidyasagar; Budansky, Yuri; Bykov, Alexei A; Zeylikovich, Roman; Alfano, R R

    2007-01-01

    Fluorescence and phosphorescence measurements are performed on normal and malignant ex vivo human breast tissues using UV LED and xenon lamp excitation. Tryptophan (trp) phosphorescence intensity is higher in both normal glandular and adipose tissue when compared to malignant tissue. An algorithm based on the ratio of trp fluorescence intensity at 345 nm to phosphorescence intensity at 500 nm is successfully used to separate normal from malignant tissue types. Normal specimens consistently exhibited a low I(345)I(500) ratio (<10), while for malignant specimens, the I(345)I(500) ratio is consistently high (>15). The ratio analysis correlates well with histopathology. Intensity ratio maps with a spatial resolution of 0.5 mm are generated in which local regions of malignancy could be identified.

  8. Kβ/ Kα intensity ratios for X-ray production in 3d metals by gamma-rays and protons

    NASA Astrophysics Data System (ADS)

    Bhuinya, C. R.; Padhi, H. C.

    1994-04-01

    Systematic measurements of Kβ/ Kα intensity ratios for X-ray production in 3d metals have been carried out using γ-ray and fast proton ionization methods. The measured ratios from proton ionization experiments indicate production of multivacancies in the L shell giving rise to higher Kβ/ Kα ratios compared to the present γRF results and 2 MeV proton ionization results of Perujo et al. [Perujo A., Maxwell J. A., Teesdale W. J. and Cambell J. L. (1987) J. Phys. B: Atom. Molec. Phys.20, 4973]. This is consistent with the SCA model calculation which gives increased simultaneous K- and L-shell ionization at 4 MeV. The present results from γRF experiments are in close agreement with the 2 MeV proton ionization results of Perujo et al. (1987) and also with the theoretical calculation of jankowski and Polasik [Jankowski K. and Polasik M. (1989) J. Phys. B: Atom. Molec. Optic. Phys. 22, 2369] but the theoretical results of Scofield [Scofield J. H. (1974a) Atom. Data Nucl. Data Tables14, 12] are somewhat higher.

  9. Measurement of concrete strength using the emission intensity ratio between Ca(II) 396.8 nm and Ca(I) 422.6 nm in a Nd:YAG laser-induced plasma.

    PubMed

    Tsuyuki, Kenichiro; Miura, Satoru; Idris, Nasrullah; Kurniawan, Koo Hendrik; Lie, Tjung Jie; Kagawa, Kiichiro

    2006-01-01

    An experiment to investigate the potential of a laser-induced plasma method for determining concrete compressive strength was conducted by focusing a Nd:YAG laser on concrete samples with different degrees of compressive strength. This technique was developed in light of the role of the shock wave in the generation of a laser-induced plasma. It was found that the speed of the shock front depends on the hardness of the sample. It was also found that a positive relationship exists between the speed of the shock front and the ionization rate of the ablated atoms. Hence, the ratio of the intensity between the Ca(II) 396.8 nm and Ca(I) 422.6 nm emission lines detected from the laser-induced plasma can be used to examine the hardness of the material. In fact, it was observed that the ratio changes with respect to the change in the concrete compressive strength. The findings also show that the ratio increases with time after the cement is mixed with water.

  10. Evaluation of blood glucose concentration measurement using photoacoustic spectroscopy in near-infrared region

    NASA Astrophysics Data System (ADS)

    Namita, Takeshi; Sato, Mitsuki; Kondo, Kengo; Yamakawa, Makoto; Shiina, Tsuyoshi

    2017-03-01

    Diabetes, a typical lifestyle-related disease, is an important disease presenting risks of various complications such as retinopathy, kidney failure, and nervous neuropathy. To treat diabetes, regular and continual self-measurement of blood glucose concentrations is necessary to maintain blood glucose levels and to prevent complications. Usually, daily measurements are taken using invasive methods such as finger-prick blood sampling. Some non-invasive optical techniques have been proposed to reduce pain and infection risk, however, few practical techniques exist today. To realize highly accurate and practical measurement of blood glucose concentrations, the feasibility of a photoacoustic method using near-infrared light was evaluated. A photoacoustic signal from a solution of glucose in water (+0-5 g/dl) or equine blood (+0-400 mg/dl) was measured using a hydrophone (9 mm diameter) at 800-1800 nm wavelengths. We investigated the relation between the glucose solution concentration and the photoacoustic signal intensity or peak position of the received photoacoustic signal (i.e. speed of sound in solutions). Results show that the signal intensity and sound speed of the glucose solution increase with increased glucose concentration for wavelengths at which light absorbance of glucose is high. For quantitative estimation of the glucose solution concentration, the photoacoustic signal intensity ratio between two wavelengths, at which dependence of the signal intensity on glucose concentration is high and low, was calculated. Results confirmed that the signal intensity ratios increase linearly with the glucose concentration. These analyses verified the feasibility of glucose level estimation using photoacoustic measurement in the near-infrared region.

  11. A simple optode based method for imaging O2 distribution and dynamics in tap water biofilms.

    PubMed

    Staal, M; Prest, E I; Vrouwenvelder, J S; Rickelt, L F; Kühl, M

    2011-10-15

    A ratiometric luminescence intensity imaging approach is presented, which enables spatial O2 measurements in biofilm reactors with transparent planar O2 optodes. Optodes consist of an O2 sensitive luminescent dye immobilized in a 1-10 μm thick polymeric layer on a transparent carrier, e.g. a glass window. The method is based on sequential imaging of the O2 dependent luminescence intensity, which are subsequently normalized with luminescent intensity images recorded under anoxic conditions. We present 2-dimensional O2 distribution images at the base of a tap water biofilm measured with the new ratiometric method and compare the results with O2 distribution images obtained in the same biofilm reactor with luminescence lifetime imaging. Using conventional digital cameras, such simple normalized luminescence intensity imaging can yield images of 2-dimensional O2 distributions with a high signal-to-noise ratio and spatial resolution comparable or even surpassing those obtained with expensive and complex luminescence lifetime imaging systems. The method can be applied to biofilm growth incubators allowing intermittent experimental shifts to anoxic conditions or in systems, in which the O2 concentration is depleted during incubation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Quantitative characterization of fatty liver disease using x-ray scattering

    NASA Astrophysics Data System (ADS)

    Elsharkawy, Wafaa B.; Elshemey, Wael M.

    2013-11-01

    Nonalcoholic fatty liver disease (NAFLD) is a dynamic condition in which fat abnormally accumulates within the hepatocytes. It is believed to be a marker of risk of later chronic liver diseases, such as liver cirrhosis and carcinoma. The fat content in liver biopsies determines its validity for liver transplantation. Transplantation of livers with severe NAFLD is associated with a high risk of primary non-function. Moreover, NAFLD is recognized as a clinically important feature that influences patient morbidity and mortality after hepatic resection. Unfortunately, there is a lack in a precise, reliable and reproducible method for quantification of NAFLD. This work suggests a method for the quantification of NAFLD. The method is based on the fact that fatty liver tissue would have a characteristic x-ray scattering profile with a relatively intense fat peak at a momentum transfer value of 1.1 nm-1 compared to a soft tissue peak at 1.6 nm-1. The fat content in normal and fatty liver is plotted against three profile characterization parameters (ratio of peak intensities, ratio of area under peaks and ratio of area under fat peak to total profile area) for measured and Monte Carlo simulated x-ray scattering profiles. Results show a high linear dependence (R2>0.9) of the characterization parameters on the liver fat content with a reported high correlation coefficient (>0.9) between measured and simulated data. These results indicate that the current method probably offers reliable quantification of fatty liver disease.

  13. Optimization of morphological parameters for mitigation pits on rear KDP surface: experiments and numerical modeling.

    PubMed

    Yang, Hao; Cheng, Jian; Chen, Mingjun; Wang, Jian; Liu, Zhichao; An, Chenhui; Zheng, Yi; Hu, Kehui; Liu, Qi

    2017-07-24

    In high power laser systems, precision micro-machining is an effective method to mitigate the laser-induced surface damage growth on potassium dihydrogen phosphate (KDP) crystal. Repaired surfaces with smooth spherical and Gaussian contours can alleviate the light field modulation caused by damage site. To obtain the optimal repairing structure parameters, finite element method (FEM) models for simulating the light intensification caused by the mitigation pits on rear KDP surface were established. The light intensity modulation of these repairing profiles was compared by changing the structure parameters. The results indicate the modulation is mainly caused by the mutual interference between the reflected and incident lights on the rear surface. Owing to the total reflection, the light intensity enhancement factors (LIEFs) of the spherical and Gaussian mitigation pits sharply increase when the width-depth ratios are near 5.28 and 3.88, respectively. To achieve the optimal mitigation effect, the width-depth ratios greater than 5.3 and 4.3 should be applied to the spherical and Gaussian repaired contours. Particularly, for the cases of width-depth ratios greater than 5.3, the spherical repaired contour is preferred to achieve lower light intensification. The laser damage test shows that when the width-depth ratios are larger than 5.3, the spherical repaired contour presents higher laser damage resistance than that of Gaussian repaired contour, which agrees well with the simulation results.

  14. A Fatigue Life Prediction Method Based on Strain Intensity Factor

    PubMed Central

    Zhang, Wei; Liu, Huili; Wang, Qiang; He, Jingjing

    2017-01-01

    In this paper, a strain-intensity-factor-based method is proposed to calculate the fatigue crack growth under the fully reversed loading condition. A theoretical analysis is conducted in detail to demonstrate that the strain intensity factor is likely to be a better driving parameter correlated with the fatigue crack growth rate than the stress intensity factor (SIF), especially for some metallic materials (such as 316 austenitic stainless steel) in the low cycle fatigue region with negative stress ratios R (typically R = −1). For fully reversed cyclic loading, the constitutive relation between stress and strain should follow the cyclic stress-strain curve rather than the monotonic one (it is a nonlinear function even within the elastic region). Based on that, a transformation algorithm between the SIF and the strain intensity factor is developed, and the fatigue crack growth rate testing data of 316 austenitic stainless steel and AZ31 magnesium alloy are employed to validate the proposed model. It is clearly observed that the scatter band width of crack growth rate vs. strain intensity factor is narrower than that vs. the SIF for different load ranges (which indicates that the strain intensity factor is a better parameter than the stress intensity factor under the fully reversed load condition). It is also shown that the crack growth rate is not uniquely determined by the SIF range even under the same R, but is also influenced by the maximum loading. Additionally, the fatigue life data (strain-life curve) of smooth cylindrical specimens are also used for further comparison, where a modified Paris equation and the equivalent initial flaw size (EIFS) are involved. The results of the proposed method have a better agreement with the experimental data compared to the stress intensity factor based method. Overall, the strain intensity factor method shows a fairly good ability in calculating the fatigue crack propagation, especially for the fully reversed cyclic loading condition. PMID:28773049

  15. High sensitivity optical measurement of skin gloss

    PubMed Central

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F.; Urbach, H. Paul; Varghese, Babu

    2017-01-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the improved sensitivity of the two proposed methods using Monte Carlo simulations and experiments performed on ISO gloss calibration standards with an optical prototype. The performance and linearity of the method was compared with different professional gloss measurement devices based on the ratio of specular to diffuse intensity. We demonstrate the feasibility for in-vivo skin gloss measurements by quantifying the temporal evolution of skin gloss after application of standard paraffin cream bases on skin. The presented method opens new possibilities in the fields of cosmetology and dermatopharmacology for measuring the skin gloss and resorption kinetics and the pharmacodynamics of various external agents. PMID:29026683

  16. High sensitivity optical measurement of skin gloss.

    PubMed

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F; Urbach, H Paul; Varghese, Babu

    2017-09-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the improved sensitivity of the two proposed methods using Monte Carlo simulations and experiments performed on ISO gloss calibration standards with an optical prototype. The performance and linearity of the method was compared with different professional gloss measurement devices based on the ratio of specular to diffuse intensity. We demonstrate the feasibility for in-vivo skin gloss measurements by quantifying the temporal evolution of skin gloss after application of standard paraffin cream bases on skin. The presented method opens new possibilities in the fields of cosmetology and dermatopharmacology for measuring the skin gloss and resorption kinetics and the pharmacodynamics of various external agents.

  17. Factors affecting the water odor caused by chloramines during drinking water disinfection.

    PubMed

    Wang, An-Qi; Lin, Yi-Li; Xu, Bin; Hu, Chen-Yan; Gao, Ze-Chen; Liu, Zhi; Cao, Tong-Cheng; Gao, Nai-Yun

    2018-10-15

    Chloramine disinfection is one of the most common disinfection methods in drinking water treatment. In this study, the temporal variability of water odors during monochloramine auto-decomposition was investigated to elucidate the characteristics of odor problems caused by adopting chloramine disinfection in tap water. Odor intensities and dominant odorant contributions were determined using the flavor profile analysis (FPA) and odor active value (OAV), respectively. During auto-decomposition of monochloramine, Cl 2 /N molar ratio, pH, temperature, and the presence of NOM all affected odor intensity and odor temporal variation in drinking water. In general, decreasing pH from 8.5 to 6.0 led to increasing perceived odor intensity due to the formation of dichloramine. The major odorants responsible for chlorinous odor under acidic and non-acidic conditions were dichloramine and monochloramine, respectively. Chloraminated water with a Cl 2 /N molar ratio of 0.6 or NOM concentration <2 mg-C L -1 inhibited odor intensity. Furthermore, the influence of rechlorination on chlorinous odor intensity for chloraminated water should not be neglected. The results of this study will be beneficial for the control of chlorinous odors caused by chloramine disinfection in drinking water. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Evaluation of finite-element models and stress-intensity factors for surface cracks emanating from stress concentrations

    NASA Technical Reports Server (NTRS)

    Tan, P. W.; Raju, I. S.; Shivakumar, K. N.; Newman, J. C., Jr.

    1990-01-01

    A re-evaluation of the 3-D finite-element models and methods used to analyze surface crack at stress concentrations is presented. Previous finite-element models used by Raju and Newman for surface and corner cracks at holes were shown to have ill-shaped elements at the intersection of the hole and crack boundaries. Improved models, without these ill-shaped elements, were developed for a surface crack at a circular hole and at a semi-circular edge notch. Stress-intensity factors were calculated by both the nodal-force and virtual-crack-closure methods. Comparisons made between the previously developed stress-intensity factor equations and the results from the improved models agreed well except for configurations with large notch-radii-to-plate-thickness ratios. Stress-intensity factors for a semi-elliptical surface crack located at the center of a semi-circular edge notch in a plate subjected to remote tensile loadings were calculated using the improved models.

  19. Adaptive correction to the speckle correlation fringes by using a twisted-nematic liquid-crystal display.

    PubMed

    Hack, Erwin; Gundu, Phanindra Narayan; Rastogi, Pramod

    2005-05-10

    An innovative technique for reducing speckle noise and improving the intensity profile of the speckle correlation fringes is presented. The method is based on reducing the range of the modulation intensity values of the speckle interference pattern. After the fringe pattern is corrected adaptively at each pixel, a simple morphological filtering of the fringes is sufficient to obtain smoothed fringes. The concept is presented both analytically and by simulation by using computer-generated speckle patterns. The experimental verification is performed by using an amplitude-only spatial light modulator (SLM) in a conventional electronic speckle pattern interferometry setup. The optical arrangement for tuning a commercially available LCD array for amplitude-only behavior is described. The method of feedback to the LCD SLM to modulate the intensity of the reference beam in order to reduce the modulation intensity values is explained, and the resulting fringe pattern and increase in the signal-to-noise ratio are discussed.

  20. Separate-channel analysis of two-channel microarrays: recovering inter-spot information.

    PubMed

    Smyth, Gordon K; Altman, Naomi S

    2013-05-26

    Two-channel (or two-color) microarrays are cost-effective platforms for comparative analysis of gene expression. They are traditionally analysed in terms of the log-ratios (M-values) of the two channel intensities at each spot, but this analysis does not use all the information available in the separate channel observations. Mixed models have been proposed to analyse intensities from the two channels as separate observations, but such models can be complex to use and the gain in efficiency over the log-ratio analysis is difficult to quantify. Mixed models yield test statistics for the null distributions can be specified only approximately, and some approaches do not borrow strength between genes. This article reformulates the mixed model to clarify the relationship with the traditional log-ratio analysis, to facilitate information borrowing between genes, and to obtain an exact distributional theory for the resulting test statistics. The mixed model is transformed to operate on the M-values and A-values (average log-expression for each spot) instead of on the log-expression values. The log-ratio analysis is shown to ignore information contained in the A-values. The relative efficiency of the log-ratio analysis is shown to depend on the size of the intraspot correlation. A new separate channel analysis method is proposed that assumes a constant intra-spot correlation coefficient across all genes. This approach permits the mixed model to be transformed into an ordinary linear model, allowing the data analysis to use a well-understood empirical Bayes analysis pipeline for linear modeling of microarray data. This yields statistically powerful test statistics that have an exact distributional theory. The log-ratio, mixed model and common correlation methods are compared using three case studies. The results show that separate channel analyses that borrow strength between genes are more powerful than log-ratio analyses. The common correlation analysis is the most powerful of all. The common correlation method proposed in this article for separate-channel analysis of two-channel microarray data is no more difficult to apply in practice than the traditional log-ratio analysis. It provides an intuitive and powerful means to conduct analyses and make comparisons that might otherwise not be possible.

  1. The role of T1 perfusion-based classification in magnetic resonance-guided high-intensity focused ultrasound ablation of uterine fibroids.

    PubMed

    Keserci, Bilgin; Duc, Nguyen Minh

    2017-12-01

    To comparatively evaluate the role of magnetic resonance (MR) T1 perfusion-based time-signal intensity (SI) curves of fibroid tissue and the myometrium in classification of fibroids for predicting treatment outcomes of high-intensity focused ultrasound (HIFU) treatment. The fibroids of 74 women who underwent MR-HIFU treatment were classified into group A (time-SI curve of fibroid lower than that of the myometrium) and group B (time-SI curve of fibroid equal to or higher than that of the myometrium). Non-perfused volume (NPV) ratios immediately after treatment and fibroid volume reduction ratios and symptom severity scores (SSS) at the 6-month follow-up were retrospectively assessed. The immediate NPV ratios in groups A and B were 95.3 ± 6.3% (n = 62) and 63.8 ± 11% (n = 12), respectively. At the 6-month follow-up, the fibroid volume reduction ratios in groups A and B were 0.52 ± 0.14 (n = 50) and 0.07 ± 0.14 (n = 11), with the corresponding improvement in mean transformed SSS being 0.86 ± 0.14 and 0.19 ± 0.3, respectively. No serious adverse effects were reported. Our novel classification method could play an important role in classifying fibroids for predicting the immediate outcomes of HIFU treatment. • MRI is an important modality for outcome prediction in HIFU treatment • Patient selection is a significant factor for achieving high NPV ratio • NPV ratio is very strongly correlated with T1 perfusion-based classification • T1 perfusion-based classification is a strong predictor of treatment outcome.

  2. Analysing a cycling grand tour: Can we monitor fatigue with intensity or load ratios?

    PubMed

    Sanders, Dajo; Heijboer, Mathieu; Hesselink, Matthijs K C; Myers, Tony; Akubat, Ibrahim

    2018-06-01

    This study evaluated the changes in ratios of different intensity (rating of perceived exertion; RPE, heart rate; HR, power output; PO) and load measures (session-RPE; sRPE, individualized TRIMP; iTRIMP, Training Stress Score™; TSS) in professional cyclists. RPE, PO and HR data was collected from twelve professional cyclists (VO 2max 75 ± 6 ml∙min∙kg -1 ) during a two-week baseline training period and during two cycling Grand Tours. Subjective:objective intensity (RPE:HR, RPE:PO) and load (sRPE:iTRIMP, sRPE:TSS) ratios and external:internal intensity (PO:HR) and load (TSS:iTRIMP) ratios were calculated for every session. Moderate to large increases in the RPE:HR, RPE:PO and sRPE:TSS ratios (d = 0.79-1.79) and small increases in the PO:HR and sRPE:iTRIMP ratio (d = 0.21-0.41) were observed during Grand Tours compared to baseline training data. Differences in the TSS:iTRIMP ratio were trivial to small (d = 0.03-0.27). Small to moderate week-to-week changes (d = 0.21-0.63) in the PO:HR, RPE:PO, RPE:HR, TSS:iTRIMP, sRPE:iTRIMP and sRPE:TSS were observed during the Grand Tour. Concluding, this study shows the value of using ratios of intensity and load measures in monitoring cyclists. Increases in ratios could reflect progressive fatigue that is not readily detected by changes in solitary intensity/load measures.

  3. Comparison of fluorescence rejection methods of baseline correction and shifted excitation Raman difference spectroscopy

    NASA Astrophysics Data System (ADS)

    Cai, Zhijian; Zou, Wenlong; Wu, Jianhong

    2017-10-01

    Raman spectroscopy has been extensively used in biochemical tests, explosive detection, food additive and environmental pollutants. However, fluorescence disturbance brings a big trouble to the applications of portable Raman spectrometer. Currently, baseline correction and shifted-excitation Raman difference spectroscopy (SERDS) methods are the most prevailing fluorescence suppressing methods. In this paper, we compared the performances of baseline correction and SERDS methods, experimentally and simulatively. Through the comparison, it demonstrates that the baseline correction can get acceptable fluorescence-removed Raman spectrum if the original Raman signal has good signal-to-noise ratio, but it cannot recover the small Raman signals out of large noise background. By using SERDS method, the Raman signals, even very weak compared to fluorescence intensity and noise level, can be clearly extracted, and the fluorescence background can be completely rejected. The Raman spectrum recovered by SERDS has good signal to noise ratio. It's proved that baseline correction is more suitable for large bench-top Raman system with better quality or signal-to-noise ratio, while the SERDS method is more suitable for noisy devices, especially the portable Raman spectrometers.

  4. Angular dependence of Kβ/Kα intensity ratios of thick Ti and Cu pure elements from 10-25 keV electron bombardment

    NASA Astrophysics Data System (ADS)

    Singh, B.; Kumar, S.; Prajapati, S.; Singh, B. K.; Llovet, X.; Shanker, R.

    2018-02-01

    Measurements yielding the first results on angular dependence of Kβ/Kα X-ray intensity ratios of thick Ti (Z = 22) and Cu (Z = 29) targets induced by 10-25 keV electrons are presented. The measurements were done by rotating the target surface around the electron beam direction in the angular detection range 105° ≤ θ ≤ 165° in the reflection mode using an energy dispersive Si PIN photodiode detector. The measured angular dependence of Kβ/Kα intensity ratios is shown to be almost isotropic for Ti and Cu targets for the range of detection angles, 105° ≤ θ ≤ 150°, while there is a very weak increase beyond 150° for both targets. No dependence of Kβ/Kα intensity ratios on impact energy is observed; while on average, the value of the Kβ/Kα X-ray intensity ratio for Cu is larger by about 8% than that for Ti, which indicates a weak Z-dependence of the target. The experimental results are compared with those obtained from PENELOPE MC calculations and from the Evaluated Atomic Data Library (EADL) ratios. These results on Kβ/Kα X-ray intensity ratios are found to be in reasonable agreement in the detection angle range 105° ≤ θ ≤ 150° to within uncertainties, whereas the simulation and experimental results show a very slight increase in the intensity ratio with θ as the latter attains higher values. The results presented in this work provide a direct check on the accuracy of PENELOPE at oblique incidence angles for which there has been a lack of measurements in the literature until now.

  5. Seasonal and interannual variability in surface energy partitioning and vegetation cover with grazing at shortgrass steppe

    USDA-ARS?s Scientific Manuscript database

    We evaluated shortgrass steppe energy budgets based on the Bowen Ratio Energy Balance method for three different grazing intensity treatments at the Central Plains Experimental Range Long-Term Ecological Research (CPER-LTER) site. We tested the correlations between aboveground biomass and surface en...

  6. Development of a 96-well plate iodine binding assay for amylose content determination

    USDA-ARS?s Scientific Manuscript database

    Cereal starch amylose/amylopectin (AM/AP) ratios are critical in functional properties for food and industrial applications. Conventional methods for the determination of AM/AP of cereal starches are very time consuming and labor intensive making it very difficult to screen large sample sets. Stud...

  7. Qualitative tissue differentiation by analysing the intensity ratios of atomic emission lines using laser induced breakdown spectroscopy (LIBS): prospects for a feedback mechanism for surgical laser systems.

    PubMed

    Kanawade, Rajesh; Mahari, Fanuel; Klämpfl, Florian; Rohde, Maximilian; Knipfer, Christian; Tangermann-Gerk, Katja; Adler, Werner; Schmidt, Michael; Stelzle, Florian

    2015-01-01

    The research work presented in this paper focuses on qualitative tissue differentiation by monitoring the intensity ratios of atomic emissions using 'Laser Induced Breakdown Spectroscopy' (LIBS) on the plasma plume created during laser tissue ablation. The background of this study is to establish a real time feedback control mechanism for clinical laser surgery systems during the laser ablation process. Ex-vivo domestic pig tissue samples (muscle, fat, nerve and skin) were used in this experiment. Atomic emission intensity ratios were analyzed to find a characteristic spectral line for each tissue. The results showed characteristic elemental emission intensity ratios for the respective tissues. The spectral lines and intensity ratios of these specific elements varied among the different tissue types. The main goal of this study is to qualitatively and precisely identify different tissue types for tissue specific laser surgery. © 2015 The Authors. Journal of Biophotonics published by WILEY-VCH Verlag.

  8. Intensive Blood-Pressure Control in Hypertensive Chronic Kidney Disease

    PubMed Central

    Appel, Lawrence J.; Wright, Jackson T.; Greene, Tom; Agodoa, Lawrence Y.; Astor, Brad C.; Bakris, George L.; Cleveland, William H.; Charleston, Jeanne; Contreras, Gabriel; Faulkner, Marquetta L.; Gabbai, Francis B.; Gassman, Jennifer J.; Hebert, Lee A.; Jamerson, Kenneth A.; Kopple, Joel D.; Kusek, John W.; Lash, James P.; Lea, Janice P.; Lewis, Julia B.; Lipkowitz, Michael S.; Massry, Shaul G.; Miller, Edgar R.; Norris, Keith; Phillips, Robert A.; Pogue, Velvie A.; Randall, Otelio S.; Rostand, Stephen G.; Smogorzewski, Miroslaw J.; Toto, Robert D.; Wang, Xuelei

    2013-01-01

    BACKGROUND In observational studies, the relationship between blood pressure and end-stage renal disease (ESRD) is direct and progressive. The burden of hypertension-related chronic kidney disease and ESRD is especially high among black patients. Yet few trials have tested whether intensive blood-pressure control retards the progression of chronic kidney disease among black patients. METHODS We randomly assigned 1094 black patients with hypertensive chronic kidney disease to receive either intensive or standard blood-pressure control. After completing the trial phase, patients were invited to enroll in a cohort phase in which the blood-pressure target was less than 130/80 mm Hg. The primary clinical outcome in the cohort phase was the progression of chronic kidney disease, which was defined as a doubling of the serum creatinine level, a diagnosis of ESRD, or death. Follow-up ranged from 8.8 to 12.2 years. RESULTS During the trial phase, the mean blood pressure was 130/78 mm Hg in the intensive-control group and 141/86 mm Hg in the standard-control group. During the cohort phase, corresponding mean blood pressures were 131/78 mm Hg and 134/78 mm Hg. In both phases, there was no significant between-group difference in the risk of the primary outcome (hazard ratio in the intensive-control group, 0.91; P = 0.27). However, the effects differed according to the baseline level of proteinuria (P = 0.02 for interaction), with a potential benefit in patients with a protein-to-creatinine ratio of more than 0.22 (hazard ratio, 0.73; P = 0.01). CONCLUSIONS In overall analyses, intensive blood-pressure control had no effect on kidney disease progression. However, there may be differential effects of intensive blood-pressure control in patients with and those without baseline proteinuria. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases, the National Center on Minority Health and Health Disparities, and others.) PMID:20818902

  9. Detection of atheroma using Photofrin IIr and laser-induced fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Vari, Sandor G.; Papazoglou, Theodore G.; van der Veen, Maurits J.; Papaioannou, Thanassis; Fishbein, Michael C.; Chandra, Mudjianto; Beeder, Clain; Shi, Wei-Qiang; Grundfest, Warren S.

    1991-06-01

    The goal of this study was to investigate laser induced fluorescence spectroscopy (LIFS) as a method of localization of atherosclerotic lesions not visible by angiography using Photofrin IIr enhanced fluorescence. Twenty-four New Zealand White rabbits divided into six groups varying in type of arterial wall lesion and Photofrin IIr administration time (i.v.) were used. Aortic wall fluorescence signals were acquired from the aortic arch to iliac bifurcation. The output of a He-Cd laser (442 nm, 17 mW) was directed at the arterial wall through a 400 micron fiber. The fluorescence signal created in the arterial wall was collected via the same fiber and analyzed by an optical multi-channel analyzer (OMA). The ratio of fluorescence intensities at 630 nm (Photofrin IIr) and 540 nm (autofluorescence of artery wall) was analyzed (I630nm/I540nm). Intensity ratio values 24 hours after administration of Photofrin IIr were found to be as follows: in normal artery wall of 0.30 +/- 0.14 (n equals 3), in mechanically damaged wall of 0.91 +/- 0.65 (n equals 2) and, in atheromatous tissue, 0.88 +/- 0.54 (n equals 4). The intensity ratio of atheromatous tissue without Photofrin IIr was 0.23 +/- 0.04 (n equals 7). These results suggest that the use of Photofrin IIr allows in vivo atheroma detection by LIFS because of its ability to accumulate in atheroma. In addition, accumulation of Photofrin IIr was found in artery walls traumatized by balloon catheter intervention. Using this method, a catheter-based LIFS system may be developed for atheroma detection.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kastner, S.O.; Bhatia, A.K.

    A generalized method for obtaining individual level population ratios is used to obtain relative intensities of extreme ultraviolet Fe XV emission lines in the range 284 --500 A, which are density dependent for electron densities in the tokamak regime or higher. Four lines in particular are found to attain quite high intensities in the high-density limit. The same calculation provides inelastic contributions to linewidths. The method connects level populations and level widths through total probabilities t/sub i/j, related to ''taboo'' probabilities of Markov chain theory. The t/sub i/j are here evaluated for a real atomic system, being therefore of potentialmore » interest to random-walk theorists who have been limited to idealized systems characterized by simplified transition schemes.« less

  11. Molecular hydrogen in the vicinity of NGC 7538 IRS 1 and IRS 2 - Temperature and ortho-to-para ratio

    NASA Technical Reports Server (NTRS)

    Hoban, Susan; Reuter, Dennis C.; Mumma, Michael J.; Storrs, Alex D.

    1991-01-01

    Near-infrared spectroscopic observations of the active star-forming region near NGC 7538 IRS 1 and IRS 2 were made. The relative intensities of the v = 1-0 Q(1), Q(3), and Q(5) lines of molecular hydrogen are used to calculate a rotational excitation temperature. Comparison of the measured intensity of the Q(2) transition relative to the intensity of Q(1) and Q(3) permitted the retrieval of the ratio of ortho-to-para hydrogen. It is found that an ortho-to-para ratio of between 1.6 and 2.35 is needed to explain the Q-branch line intensity ratios, depending on the excitation model used. This range in ortho-to-para ratios implies a range of molecular hydrogen formation temperature of approximately 105 K to 140 K.

  12. Interactions of gaseous molecules with X-ray photons and photoelectrons in AP-XPS study of solid surface in gas phase.

    PubMed

    Tao, Franklin Feng; Nguyen, Luan

    2018-04-18

    Studies of the surface of a catalyst in the gas phase via photoelectron spectroscopy is an important approach to establish a correlation between the surface of a catalyst under reaction conditions or during catalysis and its corresponding catalytic performance. Unlike the well understood interactions between photoelectrons and the atomic layers of a surface in ultrahigh vacuum (UHV) and the well-developed method of quantitative analysis of a solid surface in UHV, a fundamental understanding of the interactions between X-ray photons and gaseous molecules and between photoelectrons and molecules of the gas phase in ambient pressure X-ray photoelectron spectroscopy (AP-XPS) is lacking. Through well designed experiments, here the impact of the interactions between photoelectrons and gaseous molecules and interactions between X-ray photons and gaseous molecules on the intensity of the collected photoelectrons have been explored. How the changes in photoelectron intensity resulting from these interactions influence measurement of the authentic atomic ratio of element M to A of a solid surface has been discussed herein, and methods to correct the measured nominal atomic ratio of two elements of a solid surface upon travelling through a gas phase to its authentic atomic ratio have been developed.

  13. Optical coherence tomography: A new strategy to image planarian regeneration

    NASA Astrophysics Data System (ADS)

    Lin, Yu-Sheng; Chu, Chin-Chou; Lin, Jen-Jen; Chang, Chien-Cheng; Wang, Chun-Chieh; Wang, Chiao-Yin; Tsui, Po-Hsiang

    2014-09-01

    The planarian is widely used as a model for studying tissue regeneration. In this study, we used optical coherence tomography (OCT) for the real-time, high-resolution imaging of planarian tissue regeneration. Five planaria were sliced transversely to produce 5 head and 5 tail fragments. During a 2-week regeneration period, OCT images of the planaria were acquired to analyze the signal attenuation rates, intensity ratios, and image texture features (including contrast, correlation, homogeneity, energy, and entropy) to compare the primitive and regenerated tissues. In the head and tail fragments, the signal attenuation rates of the regenerated fragments decreased from -0.2 dB/μm to -0.05 dB/μm, between Day 1 and Day 6, and then increased to -0.2 dB/μm on Day 14. The intensity ratios decreased to approximately 0.8 on Day 6, and increased to between 0.8 and 0.9 on Day 14. The texture parameters of contrast, correlation, and homogeneity exhibited trends similar to the signal attenuation rates and intensity ratios during the planarian regeneration. The proposed OCT parameters might provide biological information regarding cell apoptosis and the formation of a mass of new cells during planarian regeneration. Therefore, OCT imaging is a potentially effective method for planarian studies.

  14. Prediction of fetal lung maturity using the lecithin/sphingomyelin (L/S) ratio analysis with a simplified sample preparation, using a commercial microtip-column combined with mass spectrometric analysis.

    PubMed

    Kwak, Ho-Seok; Chung, Hee-Jung; Choi, Young Sik; Min, Won-Ki; Jung, So Young

    2015-07-01

    Fetal lung maturity is estimated using the lecithin/sphingomyelin ratio (L/S ratio) in amniotic fluid and it is commonly measured with thin-layer chromatography (TLC). The TLC method is time consuming and technically difficult; however, it is widely used because there is no alternative. We evaluated a novel method for measuring the L/S ratio, which involves a tip-column with a cation-exchange resin and mass spectrometry. Phospholipids in the amniotic fluid were extracted using methanol and chloroform. Choline-containing phospholipids such as lecithin and sphingomyelin were purified by passing them through the tip-column. LC-MS/MS and MALDI-TOF were used to directly analyze the purified samples. The L/S ratio by mass spectrometry was calculated from the sum peak intensity of the six lecithin, and that of sphingomyelin 34:1. In 20 samples, the L/S ratio determined with TLC was significantly correlated with that obtained by LC-MS/MS and MALDI-TOF. There was a 100% concordance between the L/S ratio by TLC and that by LC-MS/MS (kappa value=1.0). The concordance between the L/S ratio by TLC and that by MALDI-TOF was also 100% (kappa value=1.0). Our method provides a faster, simpler, and more reliable assessment of fetal lung maturity. The L/S ratio measured by LC-MS/MS and MALDI-TOF offers a compelling alternative method to traditional TLC. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Evaluation of the equivalence ratio of the reacting mixture using intensity ratio of chemiluminescence in laminar partially premixed CH{sub 4}-air flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeong, Yong Ki; Jeon, Chung Hwan; Chang, Young June

    An experimental study was performed to investigate the effects of partially premixing, varying the equivalence ratios from 0.79 to 9.52, on OH*, CH* and C{sub 2}* in laminar partially premixed flames. The signals from the electronically excited states of OH*, CH* and C{sub 2}* were detected through interference filters using a photo multiplier tube, which were processed to the intensity ratios (C{sub 2}*/CH*, C{sub 2}*/OH* and CH*/OH*) to determine a correlation with the local equivalence ratios. Furthermore, the consistency between the results of the tomographic reconstruction; Abel inversion technique, image with CCD (Couple Charged Detector) camera and the local radicalmore » intensity with PMT was investigated. The results demonstrated that (1) the flames at F=<1.36 exhibited classical double flame structure, at F>=4.76, the flames exhibited non-premixed-like flame structure and the intermediate flames at 1.36

  16. Association of Sepsis-Related Mortality with Early Increase of TIMP-1/MMP-9 Ratio

    PubMed Central

    Lorente, Leonardo; Martín, María M.; Solé-Violán, Jordi; Blanquer, José; Labarta, Lorenzo; Díaz, César; Borreguero-León, Juan M.; Orbe, Josune; Rodríguez, José A.; Jiménez, Alejandro; Páramo, José A.

    2014-01-01

    Objective Higher circulating levels of tissue inhibitor of matrix metalloproteinases (TIMP)-1 at the time of severe sepsis diagnosis have been reported in nonsurviving than in surviving patients. However, the following questions remain unanswered: 1) Does TIMP-1/MMP-9 ratio differ throughout the first week of intensive care between surviving and non-surviving patients? 2) Is there an association between TIMP-1/MMP-9 ratio and sepsis severity and mortality during such period? 3) Could TIMP-1/MMP-9 ratio during the first week be used as an early biomarker of sepsis outcome? 4) Is there an association between TIMP-1/MMP-9 ratio and coagulation state and circulating cytokine levels during the first week of intensive care in these patients? The present study sought to answer these questions. Methods Multicenter, observational and prospective study carried out in six Spanish Intensive Care Units (ICUs) of 295 patients with severe sepsis. Were measured circulating levels of TIMP-1, MMP-9, tumour necrosis factor (TNF)-alpha, interleukin (IL)-10 and plasminogen activator inhibitor (PAI)-1 at day 1, 4 and 8. End-point was 30-day mortality. Results We found higher TIMP-1/MMP-9 ratio during the first week in non-surviving (n = 98) than in surviving patients (n = 197) (p<0.01). Logistic regression analyses showed that TIMP-1/MMP-9 ratio at days 1, 4 and 8 was associated with mortality. Receiver operating characteristic (ROC) curves showed that TIMP-1/MMP-9 ratio at days 1, 4 and 8 could predict mortality. There was an association between TIMP-1/MMP-9 ratio and TNF-alpha, IL-10, PAI-1 and lactic acid levels, SOFA score and platelet count at days 1, 4 and 8. Conclusions The novel findings of our study were that non-surviving septic patients showed persistently higher TIMP-1/MMP-9 ratio than survivors ones during the first week, which was associated with severity, coagulation state, circulating cytokine levels and mortality; thus representing a new biomarker of sepsis outcome. PMID:24727739

  17. Quantitative method to assess caries via fluorescence imaging from the perspective of autofluorescence spectral analysis

    NASA Astrophysics Data System (ADS)

    Chen, Q. G.; Zhu, H. H.; Xu, Y.; Lin, B.; Chen, H.

    2015-08-01

    A quantitative method to discriminate caries lesions for a fluorescence imaging system is proposed in this paper. The autofluorescence spectral investigation of 39 teeth samples classified by the International Caries Detection and Assessment System levels was performed at 405 nm excitation. The major differences in the different caries lesions focused on the relative spectral intensity range of 565-750 nm. The spectral parameter, defined as the ratio of wavebands at 565-750 nm to the whole spectral range, was calculated. The image component ratio R/(G + B) of color components was statistically computed by considering the spectral parameters (e.g. autofluorescence, optical filter, and spectral sensitivity) in our fluorescence color imaging system. Results showed that the spectral parameter and image component ratio presented a linear relation. Therefore, the image component ratio was graded as <0.66, 0.66-1.06, 1.06-1.62, and >1.62 to quantitatively classify sound, early decay, established decay, and severe decay tissues, respectively. Finally, the fluorescence images of caries were experimentally obtained, and the corresponding image component ratio distribution was compared with the classification result. A method to determine the numerical grades of caries using a fluorescence imaging system was proposed. This method can be applied to similar imaging systems.

  18. Determining the Stellar Initial Mass by Means of the 17O/18O Ratio on the AGB

    NASA Astrophysics Data System (ADS)

    De Nutte, Rutger; Decin, Leen; Olofsson, Hans; de Koter, Alex; Karakas, Amanda; Lombaert, Robin; Milam, Stefanie; Ramstedt, Sofia; Stancliffe, Richard; Homan, Ward; Van de Sande, Marie

    2016-07-01

    This poster presentsnewly obtainedcircumstellar 12C17O and 12C18O line observations, from which theline intensity are then related directly tothe 17O/18O surface abundance ratiofor a sample of nine AGB stars covering the three spectral types ().These ratios are evaluated in relation to a fundamental stellar evolution parameters: the stellar initial mass. The17O/18O ratio is shown to function as an effective method of determining the initial stellar mass. Through comparison with predictions bystellar evolution models, accurate initial mass estimates are calculated for all nine sources.

  19. Impact of mobile intensive care unit use on total ischemic time and clinical outcomes in ST-elevation myocardial infarction patients - real-world data from the Acute Coronary Syndrome Israeli Survey.

    PubMed

    Koifman, Edward; Beigel, Roy; Iakobishvili, Zaza; Shlomo, Nir; Biton, Yitschak; Sabbag, Avi; Asher, Elad; Atar, Shaul; Gottlieb, Shmuel; Alcalai, Ronny; Zahger, Doron; Segev, Amit; Goldenberg, Ilan; Strugo, Rafael; Matetzky, Shlomi

    2017-01-01

    Ischemic time has prognostic importance in ST-elevation myocardial infarction patients. Mobile intensive care unit use can reduce components of total ischemic time by appropriate triage of ST-elevation myocardial infarction patients. Data from the Acute Coronary Survey in Israel registry 2000-2010 were analyzed to evaluate factors associated with mobile intensive care unit use and its impact on total ischemic time and patient outcomes. The study comprised 5474 ST-elevation myocardial infarction patients enrolled in the Acute Coronary Survey in Israel registry, of whom 46% ( n=2538) arrived via mobile intensive care units. There was a significant increase in rates of mobile intensive care unit utilization from 36% in 2000 to over 50% in 2010 ( p<0.001). Independent predictors of mobile intensive care unit use were Killip>1 (odds ratio=1.32, p<0.001), the presence of cardiac arrest (odds ratio=1.44, p=0.02), and a systolic blood pressure <100 mm Hg (odds ratio=2.01, p<0.001) at presentation. Patients arriving via mobile intensive care units benefitted from increased rates of primary reperfusion therapy (odds ratio=1.58, p<0.001). Among ST-elevation myocardial infarction patients undergoing primary reperfusion, those arriving by mobile intensive care unit benefitted from shorter median total ischemic time compared with non-mobile intensive care unit patients (175 (interquartile range 120-262) vs 195 (interquartile range 130-333) min, respectively ( p<0.001)). Upon a multivariate analysis, mobile intensive care unit use was the most important predictor in achieving door-to-balloon time <90 min (odds ratio=2.56, p<0.001) and door-to-needle time <30 min (odds ratio=2.96, p<0.001). One-year mortality rates were 10.7% in both groups (log-rank p-value=0.98), however inverse propensity weight model, adjusted for significant differences between both groups, revealed a significant reduction in one-year mortality in favor of the mobile intensive care unit group (odds ratio=0.79, 95% confidence interval (0.66-0.94), p=0.01). Among patients with ST-elevation myocardial infarction, the utilization of mobile intensive care units is associated with increased rates of primary reperfusion, a reduction in the time interval to reperfusion, and a reduction in one-year adjusted mortality.

  20. Photographic Method For Measurement Of Image Intensifier Tube Contrast

    NASA Astrophysics Data System (ADS)

    Moore, Robert J.

    1981-07-01

    An important parameter in an image intensifier-based imaging system is the contrast of the image intensifier tube itself. This paper presents a photographic method for the measurement of the large-scale contrast of an image intensifier tube at the system level which can be performed in the clinical setting with equipment normally found in a modern Radiology Department. A strip of Lead is positioned on-center at the bottom of the grid so that a line image of 100% contrast will be presented to the input phosphor of the image intensifier when the x-ray tube is energized at low kilovoltage. The output phosphor is photographed either with an existing fluorographic camera (photospot or cine) on the imaging tower, or with a 35-mm SLR camera loaded with orthochromatic cine film through the collimating lens of the system from the position normally occupied by the television camera, during fluoroscopy, if no other camera is present on the imaging tower. The resultant on-frame optical density is measured with a densitometer in the central part of the developed frame adjacent to and behind the image of the Lead strip. These optical density readings are converted into a ratio of light intensities from the corresponding regions on the output phosphor using the characteristic curve for the type of film employed, which is obtained by means of light sensitometry. The percent contrast is then calculated from (ratio of intensities - 1)/(ratio of intensities + 1)) X 100. Using data for a variety of CsI image intensifiers used for both gastrointestinal and vascular studies, the method is shown to give measured percent contrasts with a reproducibility of no worse than-2%, independent of type of camera used or type of sensitometer used. Standards of acceptable performance based on the author's experience with this technique over the past five years are presented for systems designed for Barium studies and for systems designed for Iodine studies. The relationship between the percent contrast as defined here, the veiling glare as defined by Siedband, and the contrast ratio as normally defined is discussed, as well as the relevance of large-scale contrast of an image intensifier tube.

  1. Demonstrating the limitations of line ratio temperature diagnostic using Fe X and Fe XIV spectral line intensity observations

    NASA Technical Reports Server (NTRS)

    Brickhouse, Nancy; Esser, Ruth; Habbal, Shadia R.

    1995-01-01

    The electron temperature in the inner corona can be derived from spectral line intensity measurements by comparing the ratio of the measured intensities of two spectral lines to the ratio calculated from theoretical models. In a homogeneous plasma the line ratio technique can be used for any two lines if the ratio of the intensities is independent of the density. The corona, however, is far from homogeneous. Even large coronal holes present at the solar poles at solar minimum can be partly or completely obscured by emission from hotter and denser surrounding regions. In this paper we investigate the effect of these surrounding regions on coronal hole temperatures. using daily intensity measurements at 1.15 Rs of the Fe XIV 5303 A and Fe X 6374 A spectral lines carried out at the National Solar Observatory at Sacramento Peak. We show that the temperatures derived using the line ratio technique for these two spectral lines can vary by more than 0.8 x 10(exp 6) K due to the contribution from surrounding regions. This example demonstrates the inadequacy of spectral lines with widely separate peak temperatures for temperature diagnostic.

  2. Model and reconstruction of a K-edge contrast agent distribution with an X-ray photon-counting detector

    PubMed Central

    Meng, Bo; Cong, Wenxiang; Xi, Yan; De Man, Bruno; Yang, Jian; Wang, Ge

    2017-01-01

    Contrast-enhanced computed tomography (CECT) helps enhance the visibility for tumor imaging. When a high-Z contrast agent interacts with X-rays across its K-edge, X-ray photoelectric absorption would experience a sudden increment, resulting in a significant difference of the X-ray transmission intensity between the left and right energy windows of the K-edge. Using photon-counting detectors, the X-ray intensity data in the left and right windows of the K-edge can be measured simultaneously. The differential information of the two kinds of intensity data reflects the contrast-agent concentration distribution. K-edge differences between various matters allow opportunities for the identification of contrast agents in biomedical applications. In this paper, a general radon transform is established to link the contrast-agent concentration to X-ray intensity measurement data. An iterative algorithm is proposed to reconstruct a contrast-agent distribution and tissue attenuation background simultaneously. Comprehensive numerical simulations are performed to demonstrate the merits of the proposed method over the existing K-edge imaging methods. Our results show that the proposed method accurately quantifies a distribution of a contrast agent, optimizing the contrast-to-noise ratio at a high dose efficiency. PMID:28437900

  3. MAVEN/IUVS Apoapse Observations of the Martian FUV Dayglow

    NASA Astrophysics Data System (ADS)

    Correira, J.; Evans, J. S.; Stevens, M. H.; Schneider, N. M.; Stewart, I. F.; Deighan, J.; Jain, S.; Chaffin, M.; Crismani, M. M. J.; McClintock, B.; Holsclaw, G.; Lefèvre, F.; Lo, D.; Stiepen, A.; Clarke, J. T.; Mahaffy, P. R.; Bougher, S. W.; Bell, J. M.; Jakosky, B. M.

    2015-12-01

    We present FUV data (115 - 190 nm) from MAVEN/IUVS apoapse mode observations for the Oct 2014 through Feb 2015 time period. During apoapse mode the highly elliptical orbit of MAVEN allows for up to four apoapse disk images by IUVS per day. Maps of FUV feature intensities and intensity ratios as well as derived CO/CO2 and O/CO2 column density ratios will be shown. Column density ratios are derived from lookup tables created using the Atmospheric Ultraviolet Radiance Integrated Code [Strickland et al., 1999] in conjunction with observed intensity ratios. Column density ratios provide a measure of composition changes in the Martian atmosphere. Due to MAVEN's orbital geometry the observations from this time period focus on the southern hemisphere. The broad view provided by apoapse observations allows for the investigation of spatial and temporal variations (both long term and local time) of the atmospheric composition (via the column density ratios). IUVS FUV intensities and derived column density ratios will also be compared with model results from Mars Global Ionosphere/Thermosphere Model (MGITM) and the Mars Climate Database (MCD).

  4. Bayesian inference on multiscale models for poisson intensity estimation: applications to photon-limited image denoising.

    PubMed

    Lefkimmiatis, Stamatios; Maragos, Petros; Papandreou, George

    2009-08-01

    We present an improved statistical model for analyzing Poisson processes, with applications to photon-limited imaging. We build on previous work, adopting a multiscale representation of the Poisson process in which the ratios of the underlying Poisson intensities (rates) in adjacent scales are modeled as mixtures of conjugate parametric distributions. Our main contributions include: 1) a rigorous and robust regularized expectation-maximization (EM) algorithm for maximum-likelihood estimation of the rate-ratio density parameters directly from the noisy observed Poisson data (counts); 2) extension of the method to work under a multiscale hidden Markov tree model (HMT) which couples the mixture label assignments in consecutive scales, thus modeling interscale coefficient dependencies in the vicinity of image edges; 3) exploration of a 2-D recursive quad-tree image representation, involving Dirichlet-mixture rate-ratio densities, instead of the conventional separable binary-tree image representation involving beta-mixture rate-ratio densities; and 4) a novel multiscale image representation, which we term Poisson-Haar decomposition, that better models the image edge structure, thus yielding improved performance. Experimental results on standard images with artificially simulated Poisson noise and on real photon-limited images demonstrate the effectiveness of the proposed techniques.

  5. Utilizing the ratio and the summation of two spectral lines for estimation of optical depth: Focus on thick plasmas

    NASA Astrophysics Data System (ADS)

    Rezaei, Fatemeh; Tavassoli, Seyed Hassan

    2016-11-01

    In this paper, a study is performed on the spectral lines of plasma radiations created from focusing of the Nd:YAG laser on Al standard alloys at atmospheric air pressure. A new theoretical method is presented to investigate the evolution of the optical depth of the plasma based on the radiative transfer equation, in LTE condition. This work relies on the Boltzmann distribution, lines broadening equations, and as well as the self-absorption relation. Then, an experimental set-up is devised to extract some of plasma parameters such as temperature from modified line ratio analysis, electron density from Stark broadening mechanism, line intensities of two spectral lines in the same order of ionization from similar species, and the plasma length from the shadowgraphy section. In this method, the summation and the ratio of two spectral lines are considered for evaluation of the temporal variations of the plasma parameters in a LIBS homogeneous plasma. The main advantage of this method is that it comprises the both of thin and thick laser induced plasmas without straight calculation of self-absorption coefficient. Moreover, the presented model can also be utilized for evaluation the transition of plasma from the thin condition to the thick one. The results illustrated that by measuring the line intensities of two spectral lines at different evolution times, the plasma cooling and the growth of the optical depth can be followed.

  6. [Determination of joint contact area using MRI].

    PubMed

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  7. Using the Delphi method to develop nursing-sensitive quality indicators for the NICU.

    PubMed

    Chen, Lin; Huang, Li-Hua; Xing, Mei-Yuan; Feng, Zhi-Xian; Shao, Le-Wen; Zhang, Mei-Yun; Shao, Rong-Ya

    2017-02-01

    To develop nursing-sensitive quality indicators consistent with current medical practices in Chinese neonatal intensive care units. The development of nursing-sensitive quality indicators has become a top priority in nursing management. To the best of our knowledge, there has been no objective, scientific and sensitive evaluation of the quality of neonatal intensive care unit nursing in China. A modified Delphi technique was used to seek opinions from experts about what should be used and prioritised as indicators of quality care in neonatal intensive care unit nursing. Based on a literature review, we identified 21 indicators of nursing-sensitive quality in the neonatal intensive care unit. Our group of 11 consultants chose 13 indicators to be discussed using the Delphi method. In October and November 2014, 39 neonatal intensive care unit experts in 18 tertiary hospitals spread across six provinces participated in two rounds of Delphi panels. Of the 13 indicators discussed, 11 were identified as indicators of nursing-sensitive quality in the neonatal intensive care unit: rate of nosocomial infections, rate of accidental endotracheal extubation, rate of errors in medication administration, rate of treatment for pain, rate of peripheral venous extravasation, rate of compliance with handwashing techniques, incidence of pressure ulcers, incidence of noise, the bed-to-care ratio, the proportion of nurses with greater than five years neonatal intensive care unit experience and incidence of retinopathy. The 11 neonatal intensive care unit nursing-sensitive indicators identified by the Delphi method integrated with basic Chinese practices provide a basis for nursing management and the monitoring of nursing quality. This study identified nursing-sensitive quality indicators for neonatal intensive care unit care that are suitable for current clinical practice in China. © 2016 John Wiley & Sons Ltd.

  8. Application of neutron-gamma analysis for determination of C/N ratio in compost

    USDA-ARS?s Scientific Manuscript database

    Neutron-gamma analysis is based on the acquisition of gamma rays from neutron irradiated study objects. The intensity and energy of the registered gamma rays gives information on the types and amounts of elements in the studied object. The use of this method for measurements of soil carbon demonstra...

  9. Fluorescence ratiometric classifier for the detection of skin pathologies

    NASA Astrophysics Data System (ADS)

    Anand, Suresh; Cicchi, Riccardo; Cosci, Alessandro; Rossari, Susanna; Kapsokalyvas, Dimitrios; Baria, Enrico; Maio, Vincenza; Massi, Daniela; De Giorgi, Vincenzo; Pimpinelli, Nicola; Pavone, Francesco S.

    2015-07-01

    Detection of pre-malignant lesions in skin could help in reducing the 5 year patient mortality rates and greatly advancing the quality of life. Current gold standard for the detection of skin pathologies is a tissue biopsy and followed by a series of steps before it is examined under a light microscope by a pathologist. The disadvantage with this method is its invasiveness. Light based biomedical point spectroscopic techniques offers an adjunct technique to invasive tissue pathology. In this context, we have implemented a simple multiplexed ratiometric approach (F470/F560 and F510/F580) based on fluorescence at two excitation wavelengths 378 nm and 445 nm respectively. The emission profile at these excitation wavelengths showed a shift towards the longer wavelengths for melanoma when compared with normal and nevus. At both excitation wavelengths, we observed an increased intensity ratios for normal, followed by nevus and melanoma. This intensity ratios provide a good diagnostic capability in differentiating normal, nevus and melanocytic skin lesions. This method could be applied in vivo because of the simplicity involved in discriminating normal and pathological skin tissues.

  10. Determination of coal ash content by the combined x-ray fluorescence and scattering spectrum

    NASA Astrophysics Data System (ADS)

    Mikhailov, I. F.; Baturin, A. A.; Mikhailov, A. I.; Borisova, S. S.; Fomina, L. P.

    2018-02-01

    An alternative method is proposed for the determination of the inorganic constituent mass fraction (ash) in solid fuel by the ratio of Compton and Rayleigh X-ray scattering peaks IC/IR subject to the iron fluorescence intensity. An original X-ray optical scheme with a Ti/Mo (or Sc/Cu) double-layer secondary radiator allows registration of the combined fluorescence-and-scattering spectrum at the specified scattering angle. An algorithm for linear calibration of the Compton-to-Rayleigh IC/IR ratio is proposed which uses standard samples with two certified characteristics: mass fractions of ash (Ad) and iron oxide (WFe2O3). Ash mass fractions have been determined for coals of different deposits in the wide range of Ad from 9.4% to 52.7% mass and WFe2O3 from 0.3% to 4.95% mass. Due to the high penetrability of the probing radiation with energy E > 17 keV, the sample preparation procedure is rather simplified in comparison with the traditional method of Ad determination by the sum of fluorescence intensities of all constituent elements.

  11. Classification of normal and malignant human gastric mucosa tissue with confocal Raman microspectroscopy and wavelet analysis

    NASA Astrophysics Data System (ADS)

    Hu, Yaogai; Shen, Aiguo; Jiang, Tao; Ai, Yong; Hu, Jiming

    2008-02-01

    Thirty-two samples from the human gastric mucosa tissue, including 13 normal and 19 malignant tissue samples were measured by confocal Raman microspectroscopy. The low signal-to-background ratio spectra from human gastric mucosa tissues were obtained by this technique without any sample preparation. Raman spectral interferences include a broad featureless sloping background due to fluorescence and noise. They mask most Raman spectral feature and lead to problems with precision and quantitation of the original spectral information. A preprocessed algorithm based on wavelet analysis was used to reduce noise and eliminate background/baseline of Raman spectra. Comparing preprocessed spectra of malignant gastric mucosa tissues with those of counterpart normal ones, there were obvious spectral changes, including intensity increase at ˜1156 cm -1 and intensity decrease at ˜1587 cm -1. The quantitative criterion based upon the intensity ratio of the ˜1156 and ˜1587 cm -1 was extracted for classification of the normal and malignant gastric mucosa tissue samples. This could result in a new diagnostic method, which would assist the early diagnosis of gastric cancer.

  12. The ratioed image film thickness meter

    NASA Astrophysics Data System (ADS)

    Husen, Nicholas M.; Liu, Tianshu; Sullivan, John P.

    2018-06-01

    A technique for measuring the thickness of a fluorescent oil film is presented. Incident light is cast upon the oil film and the intensity of the luminescent signal from the fluorescent dye is ratioed with the intensity of the incident light which is scattered from the surface of the model. The quotient is independent of the intensity of the incident light and proportional to the film thickness. Experiments are presented supporting that for sufficiently thin films the ratio is independent of the intensity of the incident light as well as independent of the angle from which the experiment is imaged and the angle from which the incident light is cast.

  13. MRI non-uniformity correction through interleaved bias estimation and B-spline deformation with a template.

    PubMed

    Fletcher, E; Carmichael, O; Decarli, C

    2012-01-01

    We propose a template-based method for correcting field inhomogeneity biases in magnetic resonance images (MRI) of the human brain. At each algorithm iteration, the update of a B-spline deformation between an unbiased template image and the subject image is interleaved with estimation of a bias field based on the current template-to-image alignment. The bias field is modeled using a spatially smooth thin-plate spline interpolation based on ratios of local image patch intensity means between the deformed template and subject images. This is used to iteratively correct subject image intensities which are then used to improve the template-to-image deformation. Experiments on synthetic and real data sets of images with and without Alzheimer's disease suggest that the approach may have advantages over the popular N3 technique for modeling bias fields and narrowing intensity ranges of gray matter, white matter, and cerebrospinal fluid. This bias field correction method has the potential to be more accurate than correction schemes based solely on intrinsic image properties or hypothetical image intensity distributions.

  14. MRI Non-Uniformity Correction Through Interleaved Bias Estimation and B-Spline Deformation with a Template*

    PubMed Central

    Fletcher, E.; Carmichael, O.; DeCarli, C.

    2013-01-01

    We propose a template-based method for correcting field inhomogeneity biases in magnetic resonance images (MRI) of the human brain. At each algorithm iteration, the update of a B-spline deformation between an unbiased template image and the subject image is interleaved with estimation of a bias field based on the current template-to-image alignment. The bias field is modeled using a spatially smooth thin-plate spline interpolation based on ratios of local image patch intensity means between the deformed template and subject images. This is used to iteratively correct subject image intensities which are then used to improve the template-to-image deformation. Experiments on synthetic and real data sets of images with and without Alzheimer’s disease suggest that the approach may have advantages over the popular N3 technique for modeling bias fields and narrowing intensity ranges of gray matter, white matter, and cerebrospinal fluid. This bias field correction method has the potential to be more accurate than correction schemes based solely on intrinsic image properties or hypothetical image intensity distributions. PMID:23365843

  15. The rapid determination of fat and protein content in fresh raw milk using the laser light scattering technology

    NASA Astrophysics Data System (ADS)

    Xin, Qi; Zhi Ling, Hou; Jian Long, Tian; Zhu, Yu

    2006-08-01

    The aim was to develop a simple and rapid method for determination of fat and protein content in milk. Based on the laser light scattering theory, the ratio of the scattered light (at 90±0.05° scattering angles) intensity to the transmitted light intensity, which is called scattered-transmitted-ratio method, is adopted as the optical parameter representing the milk fat content and the protein content. In this way, the influence of the fluctuation of the power of the light source is eliminated and the accuracy of determination is improved accordingly. The system we use is real-time and can satisfy the challenging requirements of dairy farming. Results of this study indicate the feasibility of using this technology for fresh milk fat and protein analysis. The fat contents and protein contents of 50 milk samples determined by this method were consistent with the values obtained by the reference methods based on Rose-Gottlieb method and Kjeldahl determination of N method. In this paper, the operating principle of the instrument is introduced and the influence of the environmental conditions, such as the homogenization pressure and homogenization temperature, etc. on the result of the test is analyzed. Through data analysis, the concrete schemes for testing the fat using the curve fitting and testing the protein using the surface fitting technique are determined. Finally, the difference from the reference values of the test is discussed.

  16. Efficient Parallel Video Processing Techniques on GPU: From Framework to Implementation

    PubMed Central

    Su, Huayou; Wen, Mei; Wu, Nan; Ren, Ju; Zhang, Chunyuan

    2014-01-01

    Through reorganizing the execution order and optimizing the data structure, we proposed an efficient parallel framework for H.264/AVC encoder based on massively parallel architecture. We implemented the proposed framework by CUDA on NVIDIA's GPU. Not only the compute intensive components of the H.264 encoder are parallelized but also the control intensive components are realized effectively, such as CAVLC and deblocking filter. In addition, we proposed serial optimization methods, including the multiresolution multiwindow for motion estimation, multilevel parallel strategy to enhance the parallelism of intracoding as much as possible, component-based parallel CAVLC, and direction-priority deblocking filter. More than 96% of workload of H.264 encoder is offloaded to GPU. Experimental results show that the parallel implementation outperforms the serial program by 20 times of speedup ratio and satisfies the requirement of the real-time HD encoding of 30 fps. The loss of PSNR is from 0.14 dB to 0.77 dB, when keeping the same bitrate. Through the analysis to the kernels, we found that speedup ratios of the compute intensive algorithms are proportional with the computation power of the GPU. However, the performance of the control intensive parts (CAVLC) is much related to the memory bandwidth, which gives an insight for new architecture design. PMID:24757432

  17. Image analysis for dental bone quality assessment using CBCT imaging

    NASA Astrophysics Data System (ADS)

    Suprijanto; Epsilawati, L.; Hajarini, M. S.; Juliastuti, E.; Susanti, H.

    2016-03-01

    Cone beam computerized tomography (CBCT) is one of X-ray imaging modalities that are applied in dentistry. Its modality can visualize the oral region in 3D and in a high resolution. CBCT jaw image has potential information for the assessment of bone quality that often used for pre-operative implant planning. We propose comparison method based on normalized histogram (NH) on the region of inter-dental septum and premolar teeth. Furthermore, the NH characteristic from normal and abnormal bone condition are compared and analyzed. Four test parameters are proposed, i.e. the difference between teeth and bone average intensity (s), the ratio between bone and teeth average intensity (n) of NH, the difference between teeth and bone peak value (Δp) of NH, and the ratio between teeth and bone of NH range (r). The results showed that n, s, and Δp have potential to be the classification parameters of dental calcium density.

  18. Pedestal cleaning for high laser pulse contrast ratio with a 100 TW class laser system.

    PubMed

    Fourmaux, S; Payeur, S; Buffechoux, S; Lassonde, P; St-Pierre, C; Martin, F; Kieffer, J C

    2011-04-25

    Laser matter interaction at relativistic intensities using 100 TW class laser systems or higher is becoming more and more widespread. One of the critical issues of such laser systems is to let the laser pulse interact at high intensity with the solid target and avoid any pre-plasma. Thus, a high Laser Pulse Contrast Ratio (LPCR) parameter is of prime importance. We present the LPCR characterization of a high repetition 100 TW class laser system. We demonstrate that the generated Amplified Spontaneous Emission (ASE) degrades the overall LPCR performance. We propose a simple way to clean the pulse after the first amplification stage by introducing a solid state saturable absorber which results in a LPCR improvement to better than 10(10) with only a 30% energy loss at a 10 Hz repetition rate. We finally correlated this cleaning method with experimental results.

  19. Absolute sensitivity calibration of an extreme ultraviolet spectrometer for tokamak measurements

    NASA Astrophysics Data System (ADS)

    Guirlet, R.; Schwob, J. L.; Meyer, O.; Vartanian, S.

    2017-01-01

    An extreme ultraviolet spectrometer installed on the Tore Supra tokamak has been calibrated in absolute units of brightness in the range 10-340 Å. This has been performed by means of a combination of techniques. The range 10-113 Å was absolutely calibrated by using an ultrasoft-X ray source emitting six spectral lines in this range. The calibration transfer to the range 113-182 Å was performed using the spectral line intensity branching ratio method. The range 182-340 Å was calibrated thanks to radiative-collisional modelling of spectral line intensity ratios. The maximum sensitivity of the spectrometer was found to lie around 100 Å. Around this wavelength, the sensitivity is fairly flat in a 80 Å wide interval. The spatial variations of sensitivity along the detector assembly were also measured. The observed trend is related to the quantum efficiency decrease as the angle of the incoming photon trajectories becomes more grazing.

  20. The Resonance of the Surface Waves. The H/V Ratio in the Metropolitan Area of Bucharest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balan, Stefan F.; Cioflan, Carmen O.; Apostol, Bogdan F.

    2008-07-08

    The purpose of this work is to evaluate the natural period of oscillation T{sub 0} for soils in Bucharest city area. We will start by examine the elastic waves excited at the surface of an isotropic body by an oscillatory, localized force (Rayleigh waves). We define the 'H/V'-ratio as the ratio of the intensity of the in-plane waves (horizontal waves) to the intensity of the perpendicular-to-the-plane waves (vertical waves). It is shown that this ratio exhibits a resonance at a frequency which is close to the frequency of the transverse waves. It may serve to determine Poison's ratio of themore » body. We consider the ratio H/V of the horizontal to the vertical component of the Fourier spectrum for the seismic events recorded at 34 locations during the period October 2003 to August 2004. The method gives reliable data regarding the fundamental frequencies for soil deposits and the results of this experiment allows us to improve the known distribution of T{sub 0}--regularly calculated with the approximate formula T = 4h/v{sub s}. The earthquakes with M{sub w}>4 that occurred on 21.01.2004, 07.02.2004, 17.03.2004 and 04.04.2004 will be used as input to compute H/V ratios for each site of a URS stations in the area of Bucharest city. The H/V ratio is also calculated from noise recordings in the same areas. Computation of H/V spectral ratios are performed by means of the SeismicHandler and J-SESAME software showing the reliability of the method used for the sites located in Bucharest. The fundamental period obtained for the majority of sites is in accordance with already known results. By obtaining the fundamental period for much more and different spots situated in the Bucharest area we covered the zones where these data did not exist before. This study is significant in seismic risk mitigation for the Bucharest city area, for a safer seismic design and for the improvement of microzonation efforts.« less

  1. Measurement of L X-Ray Intensity Ratios for 92U and 90Th Elements Using Photoionization in an External Magnetic Field

    NASA Astrophysics Data System (ADS)

    Demir, D.; Sahin, Y.

    2007-03-01

    L x-ray intensity ratios Lell/Lγ, Lα/Lγ and Lβ/Lγ for 92U and 90Th are measured by using 59.5 keV incident photon energy at 110° and 125° scattering angles. The samples are located in the external magnetic field of intensities ±0.15T, ±0.30T, ±0.45T, ±0.60T and ±0.75T. The experimental results obtained for B = 0 are compared with the theoretical values calculated using Scofield's tables based on the Hartree-Slater theory. The contribution to the alignment of the external magnetic field is discussed. It is observed that the L x-ray intensity ratios decrease with the increasing magnetic field intensity.

  2. Stress analysis for structures with surface cracks

    NASA Technical Reports Server (NTRS)

    Bell, J. C.

    1978-01-01

    Two basic forms of analysis, one treating stresses around arbitrarily loaded circular cracks, the other treating stresses due to loads arbitrarily distributed on the surface of a half space, are united by a boundary-point least squares method to obtain analyses for stresses from surface cracks in places or bars. Calculations were for enough cases to show how effects from the crack vary with the depth-to-length ratio, the fractional penetration ratio, the obliquity of the load, and to some extent the fractional span ratio. The results include plots showing stress intensity factors, stress component distributions near the crack, and crack opening displacement patterns. Favorable comparisons are shown with two kinds of independent experiments, but the main method for confirming the results is by wide checking of overall satisfaction of boundary conditions, so that external confirmation is not essential. Principles involved in designing analyses which promote dependability of the results are proposed and illustrated.

  3. Raman spectroscopy in determination of horse meat content in the mixture with other meats.

    PubMed

    Zając, A; Hanuza, J; Dymińska, L

    2014-08-01

    A new method based on FT-Raman measurements that allows to determine the content of horse meat in its mixture with beef has been proposed. In the analysis of the Raman spectra of the meat mixtures, the integral intensity ratios of the 937/1003, 879/1003, 856/1003, 829/1003, and 480/1003cm(-1) pairs of bands have been determined the intensities of which were related to the reference intensity of the band at 1003cm(-1). The reasonable results that show good fitting between the spectroscopic parameters and chemical content of the studied samples have been obtained. The analytical equations between these parameters have been proposed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Intensity correlation imaging with sunlight-like source

    NASA Astrophysics Data System (ADS)

    Wang, Wentao; Tang, Zhiguo; Zheng, Huaibin; Chen, Hui; Yuan, Yuan; Liu, Jinbin; Liu, Yanyan; Xu, Zhuo

    2018-05-01

    We show a method of intensity correlation imaging of targets illuminated by a sunlight-like source both theoretically and experimentally. With a Faraday anomalous dispersion optical filter (FADOF), we have modulated the coherence time of a thermal source up to 0.167 ns. And we carried out measurements of temporal and spatial correlations, respectively, with an intensity interferometer setup. By skillfully using the even Fourier fitting on the very sparse sampling data, the images of targets are successfully reconstructed from the low signal-noise-ratio(SNR) interference pattern by applying an iterative phase retrieval algorithm. The resulting imaging quality is as well as the one obtained by the theoretical fitting. The realization of such a case will bring this technique closer to geostationary satellite imaging illuminated by sunlight.

  5. Hydrophobicity of silica thin films: The deconvolution and interpretation by Fourier-transform infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Saputra, Riza Eka; Astuti, Yayuk; Darmawan, Adi

    2018-06-01

    This work investigated the synthesis of dimethoxydimethylsilane:tetraethoxysilane (DMDMS:TEOS) silica thin films as well as the effect of DMDMS:TEOS molar ratios and calcination temperature on hydrophobic properties of silica thin films and its correlation with the FTIR spectra behaviour. The silica thin films were synthesized by sol-gel method using combination of DMDMS and TEOS as silica precursors, ethanol as solvent and ammonia as catalyst, with DMDMS and TEOS molar ratio of 10:90, 25:75, 50:50, 75:25 and 90:10. The results showed that DMDMS:TEOS molar ratio had significant impact on the hydrophobic properties of silica thin films coated on a glass surface. Furthermore, the correlation between water contact angle (WCA) and DMDMS:TEOS molar ratio was found to be in a parabolic shape. Concurrently, the maximum apex of the parabola obtained was observed on the DMDMS:TEOS molar ratio of 50:50 for all calcination temperature. It was clearly observed that the silica xerogel exhibiting notable change in relative peak intensities showed FTIR peak splitting of υasymmetric Si-O-Si. To uncover what happened at the FTIR peak, the deconvolution was conducted in Gaussian approach. It was established that the changes in the Gaussian peak component were related to DMDMS:TEOS molar ratios and the calcination temperature that allowed us to tailor the DMDMS:TEOS silica polymer structure model based on the peak intensity ratios. With the increase of DMDMS:TEOS molar ratio, the ratio of (cyclic Si-O-Si)/(linear Si-O-Si) decreased, whilst the ratio of (C-H)/(linear Si-O-Si) increased. Both ratios intersected at DMDMS:TEOS molar ratio of 50:50 with contribution factor ratio of 1:16 and 1:50 for silica xerogel calcined at 300 °C and 500 °C respectively. The importance of this research is the DMDMS:TEOS molar ratio plays an important role in determining the hydrophobic properties of thin films.

  6. DS — Software for analyzing data collected using double sampling

    USGS Publications Warehouse

    Bart, Jonathan; Hartley, Dana

    2011-01-01

    DS analyzes count data to estimate density or relative density and population size when appropriate. The software is available at http://iwcbm.dev4.fsr.com/IWCBM/default.asp?PageID=126. The software was designed to analyze data collected using double sampling, but it also can be used to analyze index data. DS is not currently configured to apply distance methods or methods based on capture-recapture theory. Double sampling for the purpose of this report means surveying a sample of locations with a rapid method of unknown accuracy and surveying a subset of these locations using a more intensive method assumed to yield unbiased estimates. "Detection ratios" are calculated as the ratio of results from rapid surveys on intensive plots to the number actually present as determined from the intensive surveys. The detection ratios are used to adjust results from the rapid surveys. The formula for density is (results from rapid survey)/(estimated detection ratio from intensive surveys). Population sizes are estimated as (density)(area). Double sampling is well-established in the survey sampling literature—see Cochran (1977) for the basic theory, Smith (1995) for applications of double sampling in waterfowl surveys, Bart and Earnst (2002, 2005) for discussions of its use in wildlife studies, and Bart and others (in press) for a detailed account of how the method was used to survey shorebirds across the arctic region of North America. Indices are surveys that do not involve complete counts of well-defined plots or recording information to estimate detection rates (Thompson and others, 1998). In most cases, such data should not be used to estimate density or population size but, under some circumstances, may be used to compare two densities or estimate how density changes through time or across space (Williams and others, 2005). The Breeding Bird Survey (Sauer and others, 2008) provides a good example of an index survey. Surveyors record all birds detected but do not record any information, such as distance or whether each bird is recorded in subperiods, that could be used to estimate detection rates. Nonetheless, the data are widely used to estimate temporal trends and spatial patterns in abundance (Sauer and others, 2008). DS produces estimates of density (or relative density for indices) by species and stratum. Strata are usually defined using region and habitat but other variables may be used, and the entire study area may be classified as a single stratum. Population size in each stratum and for the entire study area also is estimated for each species. For indices, the estimated totals generally are only useful if (a) plots are surveyed so that densities can be calculated and extrapolated to the entire study area and (b) if the detection rates are close to 1.0. All estimates are accompanied by standard errors (SE) and coefficients of variation (CV, that is, SE/estimate).

  7. Ratioed scatter diagrams - An erotetic method for phase identification on complex surfaces using scanning Auger microscopy

    NASA Technical Reports Server (NTRS)

    Browning, R.

    1984-01-01

    By ratioing multiple Auger intensities and plotting a two-dimensional occupational scatter diagram while digitally scanning across an area, the number and elemental association of surface phases can be determined. This can prove a useful tool in scanning Auger microscopic analysis of complex materials. The technique is illustrated by results from an anomalous region on the reaction zone of a SiC/Ti-6Al-4V metal matrix composite material. The anomalous region is shown to be a single phase associated with sulphur and phosphorus impurities. Imaging of a selected phase from the ratioed scatter diagram is possible and may be a useful technique for presenting multiple scanning Auger images.

  8. Three dimensional finite-element analysis of finite-thickness fracture specimens

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Newman, J. C., Jr.

    1977-01-01

    The stress-intensity factors for most of the commonly used fracture specimens (center-crack tension, single and double edge-crack tension, and compact), those that have a through-the-thickness crack, were calculated using a three dimensional finite-element elastic stress analysis. Three-dimensional singularity elements were used around the crack front. The stress intensity factors along the crack front were evaluated by using a force method, developed herein, that requires no prior assumption of either plane stress or plane strain. The calculated stress-intensity factors from the present analysis were compared with those from the literature whenever possible and were generally found to be in good agreement. The stress-intensity factors at the midplane for all specimens analyzed were within 3 percent of the two dimensional plane strain values. The stress intensity factors at the specimen surfaces were considerably lower than at the midplanes. For the center-crack tension specimens with large thickness to crack-length ratios, the stress-intensity factor reached a maximum near the surface of the specimen. In all other specimens considered the maximum stress intensity occurred at the midplane.

  9. Stable isotopic labeling-based quantitative targeted glycomics (i-QTaG).

    PubMed

    Kim, Kyoung-Jin; Kim, Yoon-Woo; Kim, Yun-Gon; Park, Hae-Min; Jin, Jang Mi; Hwan Kim, Young; Yang, Yung-Hun; Kyu Lee, Jun; Chung, Junho; Lee, Sun-Gu; Saghatelian, Alan

    2015-01-01

    Mass spectrometry (MS) analysis combined with stable isotopic labeling is a promising method for the relative quantification of aberrant glycosylation in diseases and disorders. We developed a stable isotopic labeling-based quantitative targeted glycomics (i-QTaG) technique for the comparative and quantitative analysis of total N-glycans using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). We established the analytical procedure with the chemical derivatizations (i.e., sialic acid neutralization and stable isotopic labeling) of N-glycans using a model glycoprotein (bovine fetuin). Moreover, the i-QTaG using MALDI-TOF MS was evaluated with various molar ratios (1:1, 1:2, 1:5) of (13) C6 /(12) C6 -2-aminobenzoic acid-labeled glycans from normal human serum. Finally, this method was applied to direct comparison of the total N-glycan profiles between normal human sera (n = 8) and prostate cancer patient sera (n = 17). The intensities of the N-glycan peaks from i-QTaG method showed a good linearity (R(2) > 0.99) with the amount of the bovine fetuin glycoproteins. The ratios of relative intensity between the isotopically 2-AA labeled N-glycans were close to the theoretical molar ratios (1:1, 1:2, 1:5). We also demonstrated that the up-regulation of the Lewis antigen (~82%) in sera from prostate cancer patients. In this proof-of-concept study, we demonstrated that the i-QTaG method, which enables to achieve a reliable comparative quantitation of total N-glycans via MALDI-TOF MS analysis, has the potential to diagnose and monitor alterations in glycosylation associated with disease states or biotherapeutics. © 2015 American Institute of Chemical Engineers.

  10. Practice-Level Variation in Outpatient Cardiac Care and Association With Outcomes.

    PubMed

    Clough, Jeffrey D; Rajkumar, Rahul; Crim, Matthew T; Ott, Lesli S; Desai, Nihar R; Conway, Patrick H; Maresh, Sha; Kahvecioglu, Daver C; Krumholz, Harlan M

    2016-02-23

    Utilization of cardiac services varies across regions and hospitals, yet little is known regarding variation in the intensity of outpatient cardiac care across cardiology physician practices or the association with clinical endpoints, an area of potential importance to promote efficient care. We included 7 160 732 Medicare beneficiaries who received services from 5635 cardiology practices in 2012. Beneficiaries were assigned to practices providing the plurality of office visits, and practices were ranked and assigned to quartiles using the ratio of observed to predicted annual payments per beneficiary for common cardiac services (outpatient intensity index). The median (interquartile range) outpatient intensity index was 1.00 (0.81-1.24). Mean payments for beneficiaries attributed to practices in the highest (Q4) and lowest (Q1) quartile of outpatient intensity were: all cardiac payments (Q4 $1272 vs Q1 $581; ratio, 2.2); cardiac catheterization (Q4 $215 vs Q1 $64; ratio, 3.4); myocardial perfusion imaging (Q4 $253 vs Q1 $83; ratio, 3.0); and electrophysiology device procedures (Q4 $353 vs Q1 $142; ratio, 2.5). The adjusted odds ratios (95% CI) for 1 incremental quartile of outpatient intensity for each outcome was: cardiac surgical/procedural hospitalization (1.09 [1.09, 1.10]); cardiac medical hospitalization (1.00 [0.99, 1.00]); noncardiac hospitalization (0.99 [0.99, 0.99]); and death at 1 year (1.00 [0.99, 1.00]). Substantial variation in the intensity of outpatient care exists at the cardiology practice level, and higher intensity is not associated with reduced mortality or hospitalizations. Outpatient cardiac care is a potentially important target for efforts to improve efficiency in the Medicare population. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  11. Rapidly disintegrating tablets containing taste masked metoclopramide hydrochloride prepared by extrusion-precipitation method.

    PubMed

    Randale, Shivsagar Ashok; Dabhi, Chandu Somatbhai; Tekade, Avinash Ramrao; Belgamwar, Veena Shailendra; Gattani, Surendra Ganeshlal; Surana, Sanjay Javarilal

    2010-04-01

    The purpose of this study was to mask the intensely bitter taste of metoclopramide HCl and to formulate a rapid disintegrating tablet (RDT) of the taste-masked drug. Taste masking was done by complexing metoclopramide HCl with aminoalkyl methacrylate copolymer (Eudragit EPO) in different ratio by the extrusion-precipitation method. Drug-polymer complexes (DPCs) were tested for drug content, in vitro taste in simulated salivary fluid (SSF) of pH 6.8, taste evaluation in oral cavity and molecular property. The complex having drug-polymer ratio of 1 : 2 shows significant taste masking, confirmed by drug release in SSF and in-vivo taste evaluation; therefore, it was selected for further study. Taste evaluation of DPCs in human volunteers revealed considerable taste masking with the degree of bitterness below threshold value (0.5) within 10 s, whereas, metoclopramide HCl was rated intensely bitter with a score of +3 for 10 s. Tablets were evaluated for various parameters like tensile strength, wetting time, water absorption ratio, in-vitro disintegration time, and disintegration in oral cavity. The effect of diluents, lubricants and sweetening agent (Xylisorb) on the disintegration time was also evaluated. Tablets of batch F3 containing mannitol and microcrystalline cellulose in the ratio 1 : 1 and 8% w/w crosspovidone showed faster disintegration (within 20 s) than the marketed formulation (180 s). Good correlation between in vitro disintegration behavior and in the oral cavity was recognized. Tablets of batch F3 also revealed rapid drug release (t(90), 90 s) in SGF compared with marketed formulation (t(90), 600 s).

  12. Temperature-Sensitive Coating Sensor Based on Hematite

    NASA Technical Reports Server (NTRS)

    Bencic, Timothy J.

    2011-01-01

    A temperature-sensitive coating, based on hematite (iron III oxide), has been developed to measure surface temperature using spectral techniques. The hematite powder is added to a binder that allows the mixture to be painted on the surface of a test specimen. The coating dynamically changes its relative spectral makeup or color with changes in temperature. The color changes from a reddish-brown appearance at room temperature (25 C) to a black-gray appearance at temperatures around 600 C. The color change is reversible and repeatable with temperature cycling from low to high and back to low temperatures. Detection of the spectral changes can be recorded by different sensors, including spectrometers, photodiodes, and cameras. Using a-priori information obtained through calibration experiments in known thermal environments, the color change can then be calibrated to yield accurate quantitative temperature information. Temperature information can be obtained at a point, or over an entire surface, depending on the type of equipment used for data acquisition. Because this innovation uses spectrophotometry principles of operation, rather than the current methods, which use photoluminescence principles, white light can be used for illumination rather than high-intensity short wavelength excitation. The generation of high-intensity white (or potentially filtered long wavelength light) is much easier, and is used more prevalently for photography and video technologies. In outdoor tests, the Sun can be used for short durations as an illumination source as long as the amplitude remains relatively constant. The reflected light is also much higher in intensity than the emitted light from the inefficient current methods. Having a much brighter surface allows a wider array of detection schemes and devices. Because color change is the principle of operation, the development of high-quality, lower-cost digital cameras can be used for detection, as opposed to the high-cost imagers needed for intensity measurements with the current methods. Alternative methods of detection are possible to increase the measurement sensitivity. For example, a monochrome camera can be used with an appropriate filter and a radiometric measurement of normalized intensity change that is proportional to the change coating temperature. Using different spectral regions yields different sensitivities and calibration curves for converting intensity change to temperature units. Alternatively, using a color camera, a ratio of the standard red, green, and blue outputs can be used as a self-referenced change. The blue region (less than 500 nm) does not change nearly as much as the red region (greater than 575 nm), so a ratio of color intensities will yield a calibrated temperature image. The new temperature sensor coating is easy to apply, is inexpensive, can contour complex shape surfaces, and can be a global surface measurement system based on spectrophotometry. The color change, or relative intensity change, at different colors makes the optical detection under white light illumination, and associated interpretation, much easier to measure and interpret than in the detection systems of the current methods.

  13. Study on gold concentrate leaching by iodine-iodide

    NASA Astrophysics Data System (ADS)

    Wang, Hai-xia; Sun, Chun-bao; Li, Shao-ying; Fu, Ping-feng; Song, Yu-guo; Li, Liang; Xie, Wen-qing

    2013-04-01

    Gold extraction by iodine-iodide solution is an effective and environment-friendly method. In this study, the method using iodine-iodide for gold leaching is proved feasible through thermodynamic calculation. At the same time, experiments on flotation gold concentrates were carried out and encouraging results were obtained. Through optimizing the technological conditions, the attained high gold leaching rate is more than 85%. The optimum process conditions at 25°C are shown as follows: the initial iodine concentration is 1.0%, the iodine-to-iodide mole ratio is 1:8, the solution pH value is 7, the liquid-to-solid mass ratio is 4:1, the leaching time is 4 h, the stirring intensity is 200 r/mim, and the hydrogen peroxide consumption is 1%.

  14. Design of a 50/50 splitting ratio non-polarizing beam splitter based on the modal method with fused-silica transmission gratings

    NASA Astrophysics Data System (ADS)

    Zhao, Huajun; Yuan, Dairong; Ming, Hai

    2011-04-01

    The optical design of a beam splitter that has a 50/50 splitting ratio regardless of the polarization is presented. The non-polarizing beam splitter (NPBS) is based on the fused-silica rectangular transmission gratings with high intensity tolerance. The modal method has been used to estimate the effective index of the modes excited in the grating region for TE and TM polarizations. If a phase difference equals an odd multiples of π/2 for the first two modes (i.e. modes 0 and 1), the incident light will be diffracted into the 0 and -1 orders with about 50% and 50% diffraction efficiency for TM and TE polarizations, respectively.

  15. Noise-induced extinction for a ratio-dependent predator-prey model with strong Allee effect in prey

    NASA Astrophysics Data System (ADS)

    Mandal, Partha Sarathi

    2018-04-01

    In this paper, we study a stochastically forced ratio-dependent predator-prey model with strong Allee effect in prey population. In the deterministic case, we show that the model exhibits the stable interior equilibrium point or limit cycle corresponding to the co-existence of both species. We investigate a probabilistic mechanism of the noise-induced extinction in a zone of stable interior equilibrium point. Computational methods based on the stochastic sensitivity function technique are applied for the analysis of the dispersion of random states near stable interior equilibrium point. This method allows to construct a confidence domain and estimate the threshold value of the noise intensity for a transition from the coexistence to the extinction.

  16. Cost of improving Access to Psychological Therapies (IAPT) programme: an analysis of cost of session, treatment and recovery in selected Primary Care Trusts in the East of England region.

    PubMed

    Radhakrishnan, Muralikrishnan; Hammond, Geoffrey; Jones, Peter B; Watson, Alison; McMillan-Shields, Fiona; Lafortune, Louise

    2013-01-01

    Recent literature on Improving Access to Psychological Therapies (IAPT) has reported on improvements in clinical outcomes, changes in employment status and the concept of recovery attributable to IAPT treatment, but not on the costs of the programme. This article reports the costs associated with a single session, completed course of treatment and recovery for four treatment courses (i.e., remaining in low or high intensity treatment, stepping up or down) in IAPT services in 5 East of England region Primary Care Trusts. Costs were estimated using treatment activity data and gross financial information, along with assumptions about how these financial data could be broken down. The estimated average cost of a high intensity session was £177 and the average cost for a low intensity session was £99. The average cost of treatment was £493 (low intensity), £1416 (high intensity), £699 (stepped down), £1514 (stepped up) and £877 (All). The cost per recovered patient was £1043 (low intensity), £2895 (high intensity), £1653 (stepped down), £2914 (stepped up) and £1766 (All). Sensitivity analysis revealed that the costs are sensitive to cost ratio assumptions, indicating that inaccurate ratios are likely to influence overall estimates. Results indicate the cost per session exceeds previously reported estimates, but cost of treatment is only marginally higher. The current cost estimates are supportive of the originally proposed IAPT model on cost-benefit grounds. The study also provides a framework to estimate costs using financial data, especially when programmes have block contract arrangements. Replication and additional analyses along with evidence-based discussion regarding alternative, cost-effective methods of intervention is recommended. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Intensity-based masking: A tool to improve functional connectivity results of resting-state fMRI.

    PubMed

    Peer, Michael; Abboud, Sami; Hertz, Uri; Amedi, Amir; Arzy, Shahar

    2016-07-01

    Seed-based functional connectivity (FC) of resting-state functional MRI data is a widely used methodology, enabling the identification of functional brain networks in health and disease. Based on signal correlations across the brain, FC measures are highly sensitive to noise. A somewhat neglected source of noise is the fMRI signal attenuation found in cortical regions in close vicinity to sinuses and air cavities, mainly in the orbitofrontal, anterior frontal and inferior temporal cortices. BOLD signal recorded at these regions suffers from dropout due to susceptibility artifacts, resulting in an attenuated signal with reduced signal-to-noise ratio in as many as 10% of cortical voxels. Nevertheless, signal attenuation is largely overlooked during FC analysis. Here we first demonstrate that signal attenuation can significantly influence FC measures by introducing false functional correlations and diminishing existing correlations between brain regions. We then propose a method for the detection and removal of the attenuated signal ("intensity-based masking") by fitting a Gaussian-based model to the signal intensity distribution and calculating an intensity threshold tailored per subject. Finally, we apply our method on real-world data, showing that it diminishes false correlations caused by signal dropout, and significantly improves the ability to detect functional networks in single subjects. Furthermore, we show that our method increases inter-subject similarity in FC, enabling reliable distinction of different functional networks. We propose to include the intensity-based masking method as a common practice in the pre-processing of seed-based functional connectivity analysis, and provide software tools for the computation of intensity-based masks on fMRI data. Hum Brain Mapp 37:2407-2418, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Application of laser-induced autofluorescence spectra detection in human colorectal cancer screening

    NASA Astrophysics Data System (ADS)

    Fu, Sheng; Chia, Teck-Chee; Kwek, Leong Chuan; Diong, Cheong Hoong; Tang, Choong Leong; Choen, Francis S.; Krishnan, S. M.

    2003-10-01

    We investigated 48 normal patients and 25 diseased patients using our laser-induced autofluorescence spectra detection system during their regular colonoscopy. The colon and rectum mucosa autofluorescence were excited by 405 nm continue wavelength laser. We observed that cancer or diseased colorectal mucosa, their autofluorescence spectra are significantly different from normal area. The autofluorescence spectra intensity at about 500 nm was been used for our intensity ratio characteristics intensity for our diagnostic algorithm. The intensity ratios of RI-680/I-500 and RI-630/I-500 were performed to identify the detection area. From experimental result we concluded that both intensity ratios of RI-680/I-500 and RI-630/I-500 as guidelines can detect cancerous and polyps disease completely. Our investigation provided some useful insight for laser induced autofluorescence spectra as a diagnosis technique for clinical application.

  19. Computing moment to moment BOLD activation for real-time neurofeedback

    PubMed Central

    Hinds, Oliver; Ghosh, Satrajit; Thompson, Todd W.; Yoo, Julie J.; Whitfield-Gabrieli, Susan; Triantafyllou, Christina; Gabrieli, John D.E.

    2013-01-01

    Estimating moment to moment changes in blood oxygenation level dependent (BOLD) activation levels from functional magnetic resonance imaging (fMRI) data has applications for learned regulation of regional activation, brain state monitoring, and brain-machine interfaces. In each of these contexts, accurate estimation of the BOLD signal in as little time as possible is desired. This is a challenging problem due to the low signal-to-noise ratio of fMRI data. Previous methods for real-time fMRI analysis have either sacrificed the ability to compute moment to moment activation changes by averaging several acquisitions into a single activation estimate or have sacrificed accuracy by failing to account for prominent sources of noise in the fMRI signal. Here we present a new method for computing the amount of activation present in a single fMRI acquisition that separates moment to moment changes in the fMRI signal intensity attributable to neural sources from those due to noise, resulting in a feedback signal more reflective of neural activation. This method computes an incremental general linear model fit to the fMRI timeseries, which is used to calculate the expected signal intensity at each new acquisition. The difference between the measured intensity and the expected intensity is scaled by the variance of the estimator in order to transform this residual difference into a statistic. Both synthetic and real data were used to validate this method and compare it to the only other published real-time fMRI method. PMID:20682350

  20. Classification of Reactor Facility Operational State Using SPRT Methods with Radiation Sensor Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez Aviles, Camila A.; Rao, Nageswara S.

    We consider the problem of inferring the operational state of a reactor facility by using measurements from a radiation sensor network, which is deployed around the facility’s ventilation stack. The radiation emissions from the stack decay with distance, and the corresponding measurements are inherently random with parameters determined by radiation intensity levels at the sensor locations. We fuse measurements from network sensors to estimate the intensity at the stack, and use this estimate in a one-sided Sequential Probability Ratio Test (SPRT) to infer the on/off state of the reactor facility. We demonstrate the superior performance of this method over conventionalmore » majority vote fusers and individual sensors using (i) test measurements from a network of NaI sensors, and (ii) emulated measurements using radioactive effluents collected at a reactor facility stack. We analytically quantify the performance improvements of individual sensors and their networks with adaptive thresholds over those with fixed ones, by using the packing number of the radiation intensity space.« less

  1. Sedation Intensity in the First 48 Hours of Mechanical Ventilation and 180-Day Mortality: A Multinational Prospective Longitudinal Cohort Study.

    PubMed

    Shehabi, Yahya; Bellomo, Rinaldo; Kadiman, Suhaini; Ti, Lian Kah; Howe, Belinda; Reade, Michael C; Khoo, Tien Meng; Alias, Anita; Wong, Yu-Lin; Mukhopadhyay, Amartya; McArthur, Colin; Seppelt, Ian; Webb, Steven A; Green, Maja; Bailey, Michael J

    2018-06-01

    In the absence of a universal definition of light or deep sedation, the level of sedation that conveys favorable outcomes is unknown. We quantified the relationship between escalating intensity of sedation in the first 48 hours of mechanical ventilation and 180-day survival, time to extubation, and delirium. Harmonized data from prospective multicenter international longitudinal cohort studies SETTING:: Diverse mix of ICUs. Critically ill patients expected to be ventilated for longer than 24 hours. Richmond Agitation Sedation Scale and pain were assessed every 4 hours. Delirium and mobilization were assessed daily using the Confusion Assessment Method of ICU and a standardized mobility assessment, respectively. Sedation intensity was assessed using a Sedation Index, calculated as the sum of negative Richmond Agitation Sedation Scale measurements divided by the total number of assessments. We used multivariable Cox proportional hazard models to adjust for relevant covariates. We performed subgroup and sensitivity analysis accounting for immortal time bias using the same variables within 120 and 168 hours. The main outcome was 180-day survival. We assessed 703 patients in 42 ICUs with a mean (SD) Acute Physiology and Chronic Health Evaluation II score of 22.2 (8.5) with 180-day mortality of 32.3% (227). The median (interquartile range) ventilation time was 4.54 days (2.47-8.43 d). Delirium occurred in 273 (38.8%) of patients. Sedation intensity, in an escalating dose-dependent relationship, independently predicted increased risk of death (hazard ratio [95% CI], 1.29 [1.15-1.46]; p < 0.001, delirium hazard ratio [95% CI], 1.25 [1.10-1.43]), p value equals to 0.001 and reduced chance of early extubation hazard ratio (95% CI) 0.80 (0.73-0.87), p value of less than 0.001. Agitation level independently predicted subsequent delirium hazard ratio [95% CI], of 1.25 (1.04-1.49), p value equals to 0.02. Delirium or mobilization episodes within 168 hours, adjusted for sedation intensity, were not associated with survival. Sedation intensity independently, in an ascending relationship, predicted increased risk of death, delirium, and delayed time to extubation. These observations suggest that keeping sedation level equivalent to a Richmond Agitation Sedation Scale 0 is a clinically desirable goal.

  2. A noninvasive method of examination of the hemostasis system.

    PubMed

    Kuznik, B I; Fine, I W; Kaminsky, A V

    2011-09-01

    We propose a noninvasive method of in vivo examination the hemostasis system based on speckle pattern analysis of coherent light scattering from the skin. We compared the results of measuring basic blood coagulation parameters by conventional invasive and noninvasive methods. A strict correlation was found between the results of measurement of soluble fibrin monomer complexes, international normalized ratio (INR), prothrombin index, and protein C content. The noninvasive method of examination of the hemostatic system enable rough evaluation of the intensity of the intravascular coagulation and correction of the dose of indirect anticoagulants maintaining desired values of INR or prothrombin index.

  3. New and improved apparatus and method for monitoring the intensities of charged-particle beams

    DOEpatents

    Varma, M.N.; Baum, J.W.

    1981-01-16

    Charged particle beam monitoring means are disposed in the path of a charged particle beam in an experimental device. The monitoring means comprise a beam monitoring component which is operable to prevent passage of a portion of beam, while concomitantly permitting passage of another portion thereof for incidence in an experimental chamber, and providing a signal (I/sub m/) indicative of the intensity of the beam portion which is not passed. Caibration means are disposed in the experimental chamber in the path of the said another beam portion and are operable to provide a signal (I/sub f/) indicative of the intensity thereof. Means are provided to determine the ratio (R) between said signals whereby, after suitable calibration, the calibration means may be removed from the experimental chamber and the intensity of the said another beam portion determined by monitoring of the monitoring means signal, per se.

  4. Variability of intensity ratios of H to He and He to ions with Z not smaller than 3 in solar energetic particle events

    NASA Technical Reports Server (NTRS)

    Van Allen, J. A.; Venkatarangan, P.; Venkatesan, D.

    1974-01-01

    Data from the solid-state detector on Explorer 35 are applied to a study of two intensity ratios in the sub-MeV per nucleon specific kinetic energy range for several energetic particle events. It is found that the intensity ratios vary markedly from event to event, particularly during the time history of the individual events. This implies that the ratios have no simple relationship to 'solar abundances' in the usual sense of the term. The pattern of the variability of each ratio is established; the ratio of He to ions with Z not smaller than 3 starts with a low value and increases as the event proceeds. The H/He ratio exhibits a qualitatively similar time history with marked relative enhancement of He early in an event. Differential diffusion of the various ionic species with differing magnetic rigidities is seen to be the dominant physical cause for the variabilities observed.

  5. [Comparative study of N, P output and eutrophication risk in runoff water in cross ridge and longitudinal ridge].

    PubMed

    Yu, Xing-Xiu; Ma, Qian; Liu, Qian-Jin; Lü, Guo-An

    2011-02-01

    Field in-situ rainfall simulation tests with two rainfall intensities (40 mm x h(-1) and 70 mm x h(-1)), which were conducted at typical sloping cropland in Yimeng mountainous area, were designed to analyze the output characteristics of dissolved inorganic nitrogen, Inorganic-N (NO3(-)-N, NH4(+) -N) and dissolved phosphorus (DP) in runoff water, as well as to compare the eutrophication risk in this water by calculating three ratios of Inorganic-N/DP, NO3(-) -N/DP, and NH4(+)-N/DP, respectively, in cross ridge and longitudinal ridge tillage methods. Results showed that, under the same rainfall intensity, the DP level in runoff water was higher in cross ridge than longitudinal ridge, while the change of different Inorganic-N level between the two tillage methods were not consistent. Cross ridge could effectively reduce runoff and the output rate of Inorganic-N and DP when compared to the longitudinal ridge tillage, which would be more outstanding with the increases of rainfall intensities. The losses of Inorganic-N and DP in runoff water were 43% and 5% less, respectively, in cross ridge than longitudinal ridge at the 40 mm x h(-1) rainfall intensity, and were 68% and 55%, respectively, at 70 mm x h(-1). The higher Inorganic-N/DP and NO3(-) -N/DP ratios suggest that runoff water from either cross ridge or longitudinal ridge tillage have a certain eutrophication risk, which present an increasing trend during the precipitation-runoff process. Compared with longitudinal ridge, cross ridge can not only hinder the increasing trend of eutrophication risk, but also can significantly lower it, and thus effectively reduce the effect of sloping cropland runoff on the eutrophication processes of receiving waters.

  6. The Interplanetary Transport Effects on the Fe/O Ratio of Large Solar Energetic Particle Events

    NASA Astrophysics Data System (ADS)

    Qin, G.; Wang, Y.

    2016-12-01

    Mason and coauthors in 2006 invested the intensities of O and Fe in large western solar energetic particle (SEP) events observed by ACE spacecraft. It was found that the Fe/O ratio decreases with time at the same kinetic energy per nucleon during the rising phase of time-intensity profile, and the Fe/O ratio gradually becomes a constant during the decay phase of intensity. However, if the O intensity is compared at a higher kinetic energy with the Fe intensity, the behaviors of intensity profiles of O and Fe are similar. So they concluded that for such kind of events the injection profiles of Fe and O are similar near the Sun, and that scattering effects dominates. With numerical simulations, we find that in order to get such kind of SEPs behavior, Fe and O have to have similar injection profiles near the Sun, and similar diffusion and adiabatic cooling processes in the interplanetary space.

  7. Two-color fluorescence analysis of individual virions determines the distribution of the copy number of proteins in herpes simplex virus particles.

    PubMed

    Clarke, Richard W; Monnier, Nilah; Li, Haitao; Zhou, Dejian; Browne, Helena; Klenerman, David

    2007-08-15

    We present a single virion method to determine absolute distributions of copy number in the protein composition of viruses and apply it to herpes simplex virus type 1. Using two-color coincidence fluorescence spectroscopy, we determine the virion-to-virion variability in copy numbers of fluorescently labeled tegument and envelope proteins relative to a capsid protein by analyzing fluorescence intensity ratios for ensembles of individual dual-labeled virions and fitting the resulting histogram of ratios. Using EYFP-tagged capsid protein VP26 as a reference for fluorescence intensity, we are able to calculate the mean and also, for the first time to our knowledge, the variation in numbers of gD, VP16, and VP22 tegument. The measurement of the number of glycoprotein D molecules was in good agreement with independent measurements of average numbers of these glycoproteins in bulk virus preparations, validating the method. The accuracy, straightforward data processing, and high throughput of this technique make it widely applicable to the analysis of the molecular composition of large complexes in general, and it is particularly suited to providing insights into virus structure, assembly, and infectivity.

  8. Distributional fold change test – a statistical approach for detecting differential expression in microarray experiments

    PubMed Central

    2012-01-01

    Background Because of the large volume of data and the intrinsic variation of data intensity observed in microarray experiments, different statistical methods have been used to systematically extract biological information and to quantify the associated uncertainty. The simplest method to identify differentially expressed genes is to evaluate the ratio of average intensities in two different conditions and consider all genes that differ by more than an arbitrary cut-off value to be differentially expressed. This filtering approach is not a statistical test and there is no associated value that can indicate the level of confidence in the designation of genes as differentially expressed or not differentially expressed. At the same time the fold change by itself provide valuable information and it is important to find unambiguous ways of using this information in expression data treatment. Results A new method of finding differentially expressed genes, called distributional fold change (DFC) test is introduced. The method is based on an analysis of the intensity distribution of all microarray probe sets mapped to a three dimensional feature space composed of average expression level, average difference of gene expression and total variance. The proposed method allows one to rank each feature based on the signal-to-noise ratio and to ascertain for each feature the confidence level and power for being differentially expressed. The performance of the new method was evaluated using the total and partial area under receiver operating curves and tested on 11 data sets from Gene Omnibus Database with independently verified differentially expressed genes and compared with the t-test and shrinkage t-test. Overall the DFC test performed the best – on average it had higher sensitivity and partial AUC and its elevation was most prominent in the low range of differentially expressed features, typical for formalin-fixed paraffin-embedded sample sets. Conclusions The distributional fold change test is an effective method for finding and ranking differentially expressed probesets on microarrays. The application of this test is advantageous to data sets using formalin-fixed paraffin-embedded samples or other systems where degradation effects diminish the applicability of correlation adjusted methods to the whole feature set. PMID:23122055

  9. Discrimination of periodontal diseases using diffuse reflectance spectral intensity ratios

    NASA Astrophysics Data System (ADS)

    Chandra Sekhar, Prasanth; Betsy, Joseph; Presanthila, Janam; Subhash, Narayanan

    2012-02-01

    This clinical study was to demonstrate the applicability of diffuse reflectance (DR) intensity ratio R620/R575 in the quantification and discrimination of periodontitis and gingivitis from healthy gingiva. DR spectral measurements were carried out with white-light illumination from 70 healthy sites in 30 healthy volunteers, and 63 gingivitis- and 58 periodontitis-infected sites in 60 patients. Clinical parameters such as probing pocket depth, clinical attachment level, and gingival index were recorded in patient population. Diagnostic accuracies for discrimination of gingivitis and periodontitis from healthy gingiva were determined by comparison of spectral signatures with clinical parameters. Divergence of average DR spectral intensity ratio between control and test groups was studied using analysis of variance. The mean DR spectrum on normalization at 620 nm showed marked differences between healthy tissue, gingivitis, and periodontitis. Hemoglobin concentration and apparent SO2 (oxygen saturation) were also calculated for healthy, gingivitis, and periodontitis sites. DR spectral intensities at 545 and 575 nm showed a decreasing trend with progression of disease. Among the various DR intensity ratios studied, the R620/R575 ratio provided a sensitivity of 90% and specificity of 94% for discrimination of healthy tissues from gingivitis and a sensitivity of 91% and specificity of 100% for discrimination of gingivitis from periodontitis.

  10. Stress intensity factors for deep cracks emanating from the corner formed by a hole intersecting a plate surface

    NASA Technical Reports Server (NTRS)

    Mcgowan, J. J.; Smith, C. W.

    1974-01-01

    A technique consisting of a marriage between stress freezing photoelasticity and a numerical method was used to obtain stress intensity factors for natural cracks emanating from the corner at which a hole intersects a plate surface. Geometrics studied were: crack depth to thickness ratios of approximately 0.2, 0.5, and 0.75; crack depth to crack length ratios of approximately 1.0 to 2.0. All final crack geometries were grown under monotonic loading and growth was not self similar with most of the growth occurring through the thickness under remote extension. Stress intensity plate surface K sub s factors were determined at the intersection of the flaw border with the plate surface K sub s and with the edge of the hole K sub h. Results showed that for the relatively shallow flaws K sub h approximately equal to 1.5 K sub s, for the moderately deep flaws K sub h approximately equal to K sub s, and for the deep flaws K sub h approximately equal to 0.5 K sub s, revealing a severe sensitivity of K to flaw geometry.

  11. Whole brain myelin mapping using T1- and T2-weighted MR imaging data

    PubMed Central

    Ganzetti, Marco; Wenderoth, Nicole; Mantini, Dante

    2014-01-01

    Despite recent advancements in MR imaging, non-invasive mapping of myelin in the brain still remains an open issue. Here we attempted to provide a potential solution. Specifically, we developed a processing workflow based on T1-w and T2-w MR data to generate an optimized myelin enhanced contrast image. The workflow allows whole brain mapping using the T1-w/T2-w technique, which was originally introduced as a non-invasive method for assessing cortical myelin content. The hallmark of our approach is a retrospective calibration algorithm, applied to bias-corrected T1-w and T2-w images, that relies on image intensities outside the brain. This permits standardizing the intensity histogram of the ratio image, thereby allowing for across-subject statistical analyses. Quantitative comparisons of image histograms within and across different datasets confirmed the effectiveness of our normalization procedure. Not only did the calibrated T1-w/T2-w images exhibit a comparable intensity range, but also the shape of the intensity histograms was largely corresponding. We also assessed the reliability and specificity of the ratio image compared to other MR-based techniques, such as magnetization transfer ratio (MTR), fractional anisotropy (FA), and fluid-attenuated inversion recovery (FLAIR). With respect to these other techniques, T1-w/T2-w had consistently high values, as well as low inter-subject variability, in brain structures where myelin is most abundant. Overall, our results suggested that the T1-w/T2-w technique may be a valid tool supporting the non-invasive mapping of myelin in the brain. Therefore, it might find important applications in the study of brain development, aging and disease. PMID:25228871

  12. Numerical study on the impact of ground heating and ambient wind speed on flow fields in street canyons

    NASA Astrophysics Data System (ADS)

    Li, Lei; Yang, Lin; Zhang, Li-Jie; Jiang, Yin

    2012-11-01

    The impact of ground heating on flow fields in street canyons under different ambient wind speed conditions was studied based on numerical methods. A series of numerical tests were performed, and three factors including height-to-width (H/W) ratio, ambient wind speed and ground heating intensity were taken into account. Three types of street canyon with H/W ratios of 0.5, 1.0 and 2.0, respectively, were used in the simulation and seven speed values ranging from 0.0 to 3.0 m s-1 were set for the ambient wind speed. The ground heating intensity, which was defined as the difference between the ground temperature and air temperature, ranged from 10 to 40 K with an increase of 10 K in the tests. The results showed that under calm conditions, ground heating could induce circulation with a wind speed of around 1.0 m s-1, which is enough to disperse pollutants in a street canyon. It was also found that an ambient wind speed threshold may exist for street canyons with a fixed H/W ratio. When ambient wind speed was lower than the threshold identified in this study, the impact of the thermal effect on the flow field was obvious, and there existed a multi-vortex flow pattern in the street canyon. When the ambient wind speed was higher than the threshold, the circulation pattern was basically determined by dynamic effects. The tests on the impact of heating intensity showed that a higher ground heating intensity could strengthen the vortical flow within the street canyon, which would help improve pollutant diffusion capability in street canyons.

  13. Enhanced Fano resonance in a non-adiabatic tapered fiber coupled with a microresonator.

    PubMed

    Zhang, Kun; Wang, Yue; Wu, Yi-Hui

    2017-08-01

    We achieved enhanced Fano resonance by coupling a bottle resonator with a special non-adiabatic tapered fiber, where there is a high intensity distribution ratio between high-order and fundamental modes in the tapered region, as well as single mode propagation in the waist region. The resonance line shape is theoretically proved to be related to the intensity distribution ratio of the two fiber modes and their phase shift. An enhanced Fano line shape with an extinction ratio over 15 dB is experimentally reached by improving the intensity distribution ratio and tuning the phase shift. The results can remarkably improve the sensitivity of whispering-gallery mode microresonators in the field of optical sensing.

  14. Spectral reconstruction for shifted-excitation Raman difference spectroscopy (SERDS).

    PubMed

    Guo, Shuxia; Chernavskaia, Olga; Popp, Jürgen; Bocklitz, Thomas

    2018-08-15

    Fluorescence emission is one of the major obstacles to apply Raman spectroscopy in biological investigations. It is usually several orders more intense than Raman scattering and hampers further analysis. In cases where the fluorescence emission is too intense to be efficiently removed via routine mathematical baseline correction algorithms, an alternative approach is needed. One alternative approach is shifted-excitation Raman difference spectroscopy (SERDS), where two Raman spectra are recorded with two slightly different excitation wavelengths. Ideally, the fluorescence emission at the two excitations does not change while the Raman spectrum shifts according to the excitation wavelength. Hence the fluorescence is removed in the difference of the two recorded Raman spectra. For better interpretability a spectral reconstruction procedure is necessary to recover the fluorescence-free Raman spectrum. This is challenging due to the intensity variations between the two recorded Raman spectra caused by unavoidable experimental changes as well as the presence of noise. Existent approaches suffer from drawbacks like spectral resolution loss, fluorescence residual, and artefacts. In this contribution, we proposed a reconstruction method based on non-negative least squares (NNLS), where the intensity variations between the two measurements are utilized in the reconstruction model. The method achieved fluorescence-free reconstruction on three real-world SERDS datasets without significant information loss. Thereafter, we quantified the performance of the reconstruction based on artificial datasets from four aspects: reconstructed spectral resolution, precision of reconstruction, signal-to-noise-ratio (SNR), and fluorescence residual. The artificial datasets were constructed with varied Raman to fluorescence intensity ratio (RFIR), SNR, full-width at half-maximum (FWHM), excitation wavelength shift, and fluorescence variation between the two spectra. It was demonstrated that the NNLS approach provides a faithful reconstruction without significantly changing the spectral resolution. Meanwhile, the reconstruction is almost robust to fluorescence variations between the two spectra. Last but not the least the SNR was improved after reconstruction for extremely noisy SERDS datasets. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Stimulated Raman diagnostics in diesel droplets

    NASA Astrophysics Data System (ADS)

    Golombok, Michael

    1991-09-01

    Stimulated Raman spectroscopy (SRS) can simultaneously measure droplet sizes and the associated component concentrations in a fuel injection. As spray evaporation is crucial in determining the performance parameters of a diesel engine, such as cold start and particulate emission formation, the new application of the method for spatially and temporally resolved measurements is a useful new diagnostic, extending our understanding of spray processes. Droplet sizes can be obtained from single shot SRS spectra by measuring the separation between morphology-dependent resonances (MDR) that correspond to standing wave modes confined near the droplet circumference. Power spectrum analysis allows the measurement of more than one droplet from a spectrum using a pumped laser sheet in the fuel spray. The MDRs are responsible for the simultaneous stimulation of multiple Raman spectral lines over and above those seen in bulk liquids. The SRS method for concentration measurement is effectively self-calibrating in that the relative intensity of two adjacent lines is used to measure concentration. Any particular fuel has a unique ratio of SRS antisymmetric to symmetric C-H stretch intensity. If individual components in a fuel blend are characterized beforehand, one can monitor the evolution of the spray during injection by measuring signal intensity ratios which yield the volume fraction of the component of interest. The SRS technique is being used to examine a number of spray dynamics phenomena such as fuel atomization, droplet evolution and front-end volatility effects, which are of current interest in diesel development studies.

  16. Intensive blood glucose control and vascular outcomes in patients with type 2 diabetes.

    PubMed

    Patel, Anushka; MacMahon, Stephen; Chalmers, John; Neal, Bruce; Billot, Laurent; Woodward, Mark; Marre, Michel; Cooper, Mark; Glasziou, Paul; Grobbee, Diederick; Hamet, Pavel; Harrap, Stephen; Heller, Simon; Liu, Lisheng; Mancia, Giuseppe; Mogensen, Carl Erik; Pan, Changyu; Poulter, Neil; Rodgers, Anthony; Williams, Bryan; Bompoint, Severine; de Galan, Bastiaan E; Joshi, Rohina; Travert, Florence

    2008-06-12

    In patients with type 2 diabetes, the effects of intensive glucose control on vascular outcomes remain uncertain. We randomly assigned 11,140 patients with type 2 diabetes to undergo either standard glucose control or intensive glucose control, defined as the use of gliclazide (modified release) plus other drugs as required to achieve a glycated hemoglobin value of 6.5% or less. Primary end points were composites of major macrovascular events (death from cardiovascular causes, nonfatal myocardial infarction, or nonfatal stroke) and major microvascular events (new or worsening nephropathy or retinopathy), assessed both jointly and separately. After a median of 5 years of follow-up, the mean glycated hemoglobin level was lower in the intensive-control group (6.5%) than in the standard-control group (7.3%). Intensive control reduced the incidence of combined major macrovascular and microvascular events (18.1%, vs. 20.0% with standard control; hazard ratio, 0.90; 95% confidence interval [CI], 0.82 to 0.98; P=0.01), as well as that of major microvascular events (9.4% vs. 10.9%; hazard ratio, 0.86; 95% CI, 0.77 to 0.97; P=0.01), primarily because of a reduction in the incidence of nephropathy (4.1% vs. 5.2%; hazard ratio, 0.79; 95% CI, 0.66 to 0.93; P=0.006), with no significant effect on retinopathy (P=0.50). There were no significant effects of the type of glucose control on major macrovascular events (hazard ratio with intensive control, 0.94; 95% CI, 0.84 to 1.06; P=0.32), death from cardiovascular causes (hazard ratio with intensive control, 0.88; 95% CI, 0.74 to 1.04; P=0.12), or death from any cause (hazard ratio with intensive control, 0.93; 95% CI, 0.83 to 1.06; P=0.28). Severe hypoglycemia, although uncommon, was more common in the intensive-control group (2.7%, vs. 1.5% in the standard-control group; hazard ratio, 1.86; 95% CI, 1.42 to 2.40; P<0.001). A strategy of intensive glucose control, involving gliclazide (modified release) and other drugs as required, that lowered the glycated hemoglobin value to 6.5% yielded a 10% relative reduction in the combined outcome of major macrovascular and microvascular events, primarily as a consequence of a 21% relative reduction in nephropathy. (ClinicalTrials.gov number, NCT00145925.) 2008 Massachusetts Medical Society

  17. Automated choroid segmentation based on gradual intensity distance in HD-OCT images.

    PubMed

    Chen, Qiang; Fan, Wen; Niu, Sijie; Shi, Jiajia; Shen, Honglie; Yuan, Songtao

    2015-04-06

    The choroid is an important structure of the eye and plays a vital role in the pathology of retinal diseases. This paper presents an automated choroid segmentation method for high-definition optical coherence tomography (HD-OCT) images, including Bruch's membrane (BM) segmentation and choroidal-scleral interface (CSI) segmentation. An improved retinal nerve fiber layer (RNFL) complex removal algorithm is presented to segment BM by considering the structure characteristics of retinal layers. By analyzing the characteristics of CSI boundaries, we present a novel algorithm to generate a gradual intensity distance image. Then an improved 2-D graph search method with curve smooth constraints is used to obtain the CSI segmentation. Experimental results with 212 HD-OCT images from 110 eyes in 66 patients demonstrate that the proposed method can achieve high segmentation accuracy. The mean choroid thickness difference and overlap ratio between our proposed method and outlines drawn by experts was 6.72µm and 85.04%, respectively.

  18. Application of focused-beam flat-sample method to synchrotron powder X-ray diffraction with anomalous scattering effect

    NASA Astrophysics Data System (ADS)

    Tanaka, M.; Katsuya, Y.; Matsushita, Y.

    2013-03-01

    The focused-beam flat-sample method (FFM), which is a method for high-resolution and rapid synchrotron X-ray powder diffraction measurements by combination of beam focusing optics, a flat shape sample and an area detector, was applied for diffraction experiments with anomalous scattering effect. The advantages of FFM for anomalous diffraction were absorption correction without approximation, rapid data collection by an area detector and good signal-to-noise ratio data by focusing optics. In the X-ray diffraction experiments of CoFe2O4 and Fe3O4 (By FFM) using X-rays near the Fe K absorption edge, the anomalous scattering effect between Fe/Co or Fe2+/Fe3+ can be clearly detected, due to the change of diffraction intensity. The change of observed diffraction intensity as the incident X-ray energy was consistent with the calculation. The FFM is expected to be a method for anomalous powder diffraction.

  19. Selective detection of cavitation bubbles by triplet pulse sequence in high-intensity focused ultrasound treatment

    NASA Astrophysics Data System (ADS)

    Iwasaki, Ryosuke; Nagaoka, Ryo; Yoshizawa, Shin; Umemura, Shin-ichiro

    2018-07-01

    Acoustic cavitation bubbles are known to enhance the heating effect in high-intensity focused ultrasound (HIFU) treatment. The detection of cavitation bubbles with high sensitivity and selectivity is required to predict the therapeutic and side effects of cavitation, and ensure the efficacy and safety of the treatment. A pulse inversion (PI) technique has been widely used for imaging microbubbles through enhancing the second-harmonic component of echo signals. However, it has difficulty in separating the nonlinear response of microbubbles from that due to nonlinear propagation. In this study, a triplet pulse (3P) method was investigated to specifically image cavitation bubbles by extracting the 1.5th fractional harmonic component. The proposed 3P method depicted cavitation bubbles with a contrast ratio significantly higher than those in conventional imaging methods with and without PI. The results suggest that the 3P method is effective for specifically detecting microbubbles in cavitation-enhanced HIFU treatment.

  20. The role of MR imaging in detection of hepatic iron overload in patients with cirrhosis of different origins

    PubMed Central

    2010-01-01

    Background There are many pathological conditions with hepatic iron overload. Classical definite diagnostic methods of these disorders are invasive and based on a direct tissue biopsy material. For the last years the role of MR imaging in liver diagnostics has been increasing. MRI shows changes of liver intensity in patients with hepatic iron overload. Changes in MR signal are an indirect consequence of change of relaxation times T2 and T2*, that can be directly measured. The purpose of the study was to evaluate usefulness of MR imaging in the detection of hepatic iron overload in patients with cirrhosis of different origins. Methods MR imaging at 1.5T was prospectively performed in 44 patients with liver cirrhosis who had undergone liver biopsy with histopathological assessment of hepatic iron deposits. In all patients the following sequences were used: SE, Express, GRE in T2 and T1-weighted images. Signal intensity (SI) was measured on images obtained with each T2 weighted sequence by means of regions of interest, placed in the liver and paraspinal muscles. The correlation between iron overload, histopathological score, serum ferritin and SI ratio was analyzed. Results In 20 patients with iron overload confirmed by the biopsy, the liver parenchyma demonstrated lower signal intensity than that of paraspinal muscles. This effect was visible only in 8 patients with hepatic iron overload in Express T2-weighted images. Higher signal intensity of liver than that of skeletal muscles on GRE - T2 weighted images was noted in 24 patients with cirrhosis and without elevated hepatic iron concentration. We observed a correlation between low and high iron concentration and liver to muscle SI ratio. Conclusion MR imaging is a useful and fast noninvasive diagnostic tool for the detection of liver iron overload in patients with cirrhosis of different origins. Liver to muscle SI ratio in GRE-T2-weighted sequence facilitates to differentiate patients with low and high degree of hepatic iron overload, which correlates with the origin of liver cirrhosis. PMID:20105330

  1. Quantification of histochemical stains using whole slide imaging: development of a method and demonstration of its usefulness in laboratory quality control.

    PubMed

    Gray, Allan; Wright, Alex; Jackson, Pete; Hale, Mike; Treanor, Darren

    2015-03-01

    Histochemical staining of tissue is a fundamental technique in tissue diagnosis and research, but it suffers from significant variability. Efforts to address this include laboratory quality controls and quality assurance schemes, but these rely on subjective interpretation of stain quality, are laborious and have low reproducibility. We aimed (1) to develop a method for histochemical stain quantification using whole slide imaging and image analysis and (2) to demonstrate its usefulness in measuring staining variation. A method to quantify the individual stain components of histochemical stains on virtual slides was developed. It was evaluated for repeatability and reproducibility, then applied to control sections of an appendix to quantify H&E staining (H/E intensities and H:E ratio) between automated staining machines and to measure differences between six regional diagnostic laboratories. The method was validated with <0.5% variation in H:E ratio measurement when using the same scanner for a batch of slides (ie, it was repeatable) but was not highly reproducible between scanners or over time, where variation of 7% was found. Application of the method showed H:E ratios between three staining machines varied from 0.69 to 0.93, H:E ratio variation over time was observed. Interlaboratory comparison demonstrated differences in H:E ratio between regional laboratories from 0.57 to 0.89. A simple method using whole slide imaging can be used to quantify and compare histochemical staining. This method could be deployed in routine quality assurance and quality control. Work is needed on whole slide imaging devices to improve reproducibility. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Improved boundary layer height measurement using a fuzzy logic method: Diurnal and seasonal variabilities of the convective boundary layer over a tropical station

    NASA Astrophysics Data System (ADS)

    Allabakash, S.; Yasodha, P.; Bianco, L.; Venkatramana Reddy, S.; Srinivasulu, P.; Lim, S.

    2017-09-01

    This paper presents the efficacy of a "tuned" fuzzy logic method at determining the height of the boundary layer using the measurements from a 1280 MHz lower atmospheric radar wind profiler located in Gadanki (13.5°N, 79°E, 375 mean sea level), India, and discusses the diurnal and seasonal variations of the measured convective boundary layer over this tropical station. The original fuzzy logic (FL) method estimates the height of the atmospheric boundary layer combining the information from the range-corrected signal-to-noise ratio, the Doppler spectral width of the vertical velocity, and the vertical velocity itself, measured by the radar, through a series of thresholds and rules, which did not prove to be optimal for our radar system and geographical location. For this reason the algorithm was tuned to perform better on our data set. Atmospheric boundary layer heights obtained by this tuned FL method, the original FL method, and by a "standard method" (that only uses the information from the range-corrected signal-to-noise ratio) are compared with those obtained from potential temperature profiles measured by collocated Global Positioning System Radio Sonde during years 2011 and 2013. The comparison shows that the tuned FL method is more accurate than the other methods. Maximum convective boundary layer heights are observed between 14:00 and 15:00 local time (LT = UTC + 5:30) for clear-sky days. These daily maxima are found to be lower during winter and postmonsoon seasons and higher during premonsoon and monsoon seasons, due to net surface radiation and convective processes over this region being more intense during premonsoon and monsoon seasons and less intense in winter and postmonsoon seasons.

  3. Presumed PDF Modeling of Early Flame Propagation in Moderate to Intense Turbulence Environments

    NASA Technical Reports Server (NTRS)

    Carmen, Christina; Feikema, Douglas A.

    2003-01-01

    The present paper describes the results obtained from a one-dimensional time dependent numerical technique that simulates early flame propagation in a moderate to intense turbulent environment. Attention is focused on the development of a spark-ignited, premixed, lean methane/air mixture with the unsteady spherical flame propagating in homogeneous and isotropic turbulence. A Monte-Carlo particle tracking method, based upon the method of fractional steps, is utilized to simulate the phenomena represented by a probability density function (PDF) transport equation. Gaussian distributions of fluctuating velocity and fuel concentration are prescribed. Attention is focused on three primary parameters that influence the initial flame kernel growth: the detailed ignition system characteristics, the mixture composition, and the nature of the flow field. The computational results of moderate and intense isotropic turbulence suggests that flames within the distributed reaction zone are not as vulnerable, as traditionally believed, to the adverse effects of increased turbulence intensity. It is also shown that the magnitude of the flame front thickness significantly impacts the turbulent consumption flame speed. Flame conditions studied have fuel equivalence ratio s in the range phi = 0.6 to 0.9 at standard temperature and pressure.

  4. Safety and therapeutic efficacy of complete or near-complete ablation of symptomatic uterine fibroid tumors by MR imaging-guided high-intensity focused US therapy.

    PubMed

    Park, Min Jung; Kim, Young-sun; Rhim, Hyunchul; Lim, Hyo Keun

    2014-02-01

    To evaluate the safety and therapeutic efficacy of magnetic resonance (MR) imaging-guided high-intensity focused ultrasound (US) ablation of symptomatic uterine fibroid tumors with an immediate nonperfused volume (NPV) ratio of 80% or more. A total of 79 women with 117 uterine tumors were treated with MR-guided high-intensity focused US ablation. Immediate NPV, complications, and therapeutic efficacy (tumor volume reduction ratio and symptom severity score [SSS] decrease at 3-mo follow-up) were retrospectively assessed. Statistical comparisons of the frequency of complications and therapeutic efficacy were performed between patients with NPV ratios of at least 80% and less than 80%. Technical success was achieved in 93.7% of cases (n = 74) of cases, and the immediate NPV ratio was 62.7% ± 25.5. Twenty-four patients exhibited an NPV ratio of at least 80% (89.7% ± 5.8), and 50 patients showed an NPV ratio of less than 80% (49.8% ± 20.7). All complications were minor in severity, and the incidences were not significantly different between groups (P > .05). The 3-month volume reduction ratio was significantly greater in patients with an NPV ratio of at least 80% (0.43 ± 0.17) than in those with an NPV ratio of less than 80% (0.20 ± 0.26; P = .002), although the decreases in SSS were not significantly different (20.9 ± 19.6 vs 12.1 ± 10.1; P = .097). In MR-guided high-intensity focused US ablation of symptomatic uterine fibroid tumors, achievement of an immediate NPV ratio of at least 80% is safe, with greater tumor volume shrinkage compared with cases with a lower NPV ratio. © 2014 SIR Published by SIR All rights reserved.

  5. Auxin-to-Gibberellin Ratio as a Signal for Light Intensity and Quality in Regulating Soybean Growth and Matter Partitioning

    PubMed Central

    Yang, Feng; Fan, Yuanfang; Wu, Xiaoling; Cheng, Yajiao; Liu, Qinlin; Feng, Lingyang; Chen, Junxu; Wang, Zhonglin; Wang, Xiaochun; Yong, Taiwen; Liu, Weiguo; Liu, Jiang; Du, Junbo; Shu, Kai; Yang, Wenyu

    2018-01-01

    The intensity and quality (red to far-red (R/Fr) ratio) of light directly affect growth of plant under shading. Gibberellins (GAs) and auxin [indole-3-acetic acid (IAA)] play important roles in mediating the shading adaptive responses of plants. Thus, the intensity and quality of the uncoupling light from shading were assessed to identify the influence of each component on the morphology and matter distribution of the leaf, stem, and petiole. This assessment was based on the changes in endogenous Gibberellin 1 (GA1) and IAA levels. Soybean plants were grown in a growth chamber with four treatments [normal (N), N+Fr, low (L), and L+Fr light]. Results revealed that the reductions in photosynthetically active radiation (PAR) and R/Fr ratio equally increased height and stem mass fractions (SMFs) of the soybean seedling. The light intensity significantly influenced the dry mass per unit area and mass fraction of soybean leaves, whereas the light quality regulated the petiole elongation and mass fraction. Low R/Fr ratio (high Fr light) increased the soybean biomass by improving the photosynthetic assimilation rate and quantum yield of photosystem II. In addition, the IAA and GA1 levels in the leaf, stem, and petiole did not reflect the growth response trends of each tissue toward light intensity and quality; however, trends of the IAA-to-GA1 content ratios were similar to those of the growth and matter allocation of each soybean tissue under different light environments. Therefore, the response of growth and matter allocation of soybean to light intensity and quality may be regulated by the IAA-to-GA1 content ratio in the tissues of the soybean plant. PMID:29441084

  6. Effects of Intensive Glucose Lowering in Type 2 Diabetes

    PubMed Central

    2015-01-01

    Background Epidemiologic studies have shown a relationship between glycated hemoglobin levels and cardiovascular events in patients with type 2 diabetes. We investigated whether intensive therapy to target normal glycated hemoglobin levels would reduce cardiovascular events in patients with type 2 diabetes who had either established cardiovascular disease or additional cardiovascular risk factors. Methods In this randomized study, 10,251 patients (mean age, 62.2 years) with a median glycated hemoglobin level of 8.1% were assigned to receive intensive therapy (targeting a glycated hemoglobin level below 6.0%) or standard therapy (targeting a level from 7.0 to 7.9%). Of these patients, 38% were women, and 35% had had a previous cardiovascular event. The primary outcome was a composite of nonfatal myocardial infarction, nonfatal stroke, or death from cardiovascular causes. The finding higher mortality in the intensive-therapy group led to a discontinuation of intensive therapy after a mean of 3.5 years of follow-up. Results At 1 year, stable median glycated hemoglobin levels of 6.4% and 7.5% were achieved in the intensive-therapy group and the standard-therapy group, respectively. During follow-up, the primary outcome occurred in 352 patients in the intensive-therapy group, as compared with 371 in the standard-therapy group (hazard ratio, 0.90; 95% confidence interval [CI], 0.78 to 1.04; P = 0.16). At the same time, 257 patients in the intensive-therapy group died, as compared with 203 patients in the standard-therapy group (hazard ratio, 1.22; 95% CI, 1.01 to 1.46; P = 0.04). Hypoglycemia requiring assistance and weight gain of more than 10 kg were more frequent in the intensive-therapy group (P<0.001). Conclusions As compared with standard therapy, the use of intensive therapy to target normal glycated hemoglobin levels for 3.5 years increased mortality and did not significantly reduce major cardiovascular events. These findings identify a previously unrecognized harm of intensive glucose lowering in high-risk patients with type 2 diabetes. (ClinicalTrials.gov number, NCT00000620.) PMID:18539917

  7. Some methods for achieving more efficient performance of fuel assemblies

    NASA Astrophysics Data System (ADS)

    Boltenko, E. A.

    2014-07-01

    More efficient operation of reactor plant fuel assemblies can be achieved through the use of new technical solutions aimed at obtaining more uniform distribution of coolant over the fuel assembly section, more intense heat removal on convex heat-transfer surfaces, and higher values of departure from nucleate boiling ratio (DNBR). Technical solutions using which it is possible to obtain more intense heat removal on convex heat-transfer surfaces and higher DNBR values in reactor plant fuel assemblies are considered. An alternative heat removal arrangement is described using which it is possible to obtain a significantly higher power density in a reactor plant and essentially lower maximal fuel rod temperature.

  8. Fluorescence detection system for microfluidic droplets

    NASA Astrophysics Data System (ADS)

    Chen, Binyu; Han, Xiaoming; Su, Zhen; Liu, Quanjun

    2018-05-01

    In microfluidic detection technology, because of the universality of optical methods in laboratory, optical detection is an attractive solution for microfluidic chip laboratory equipment. In addition, the equipment with high stability and low cost can be realized by integrating appropriate optical detection technology on the chip. This paper reports a detection system for microfluidic droplets. Photomultiplier tubes (PMT) is used as a detection device to improve the sensitivity of detection. This system improves the signal to noise ratio by software filtering and spatial filter. The fluorescence intensity is proportional to the concentration of the fluorescence and intensity of the laser. The fluorescence micro droplets of different concentrations can be distinguished by this system.

  9. Stress intensity factors for deep cracks emanating from the corner formed by a hole intersecting a plate surface

    NASA Technical Reports Server (NTRS)

    Mcgowan, J. J.; Smith, C. W.

    1976-01-01

    The stress intensity factors (SIFs) at the end points of flaws emanating from the corner formed by the intersection of a plate with a hole were determined using stress freezing photoelasticity and a numerical technique known as the Taylor series correction method to extract the SIF values from the photoelastic data. The geometries studied were crack depth to thickness ratios of about 0.2, 0.5, and 0.75; crack depth to crack length ratios of about 1.0 to 2.0; and crack length to hole radius ratios of about 0.5 to 2.0. The SIFs were determined at the intersection of the flaw border with the plate surface (KS) and with the edge of the hole (KH). It is shown that extension of a crack emanating from a corner of intersection of a hole with a plate under monotonically increasing load is not self-similar and that as the flaw depth increases, KH decreases and KS increases. Existing theories and design criteria significantly overestimate the SIF at both the hole and the surface except for shallow flaws at the hole and deep flaws at the surface.

  10. Grasland Stable Isotope Flux Measurements: Three Isotopomers of Carbon Dioxide Measured by QCL Spectroscopy

    NASA Astrophysics Data System (ADS)

    Zeeman, M. J.; Tuzson, B.; Eugster, W.; Werner, R. A.; Buchmann, N.; Emmenegger, L.

    2007-12-01

    To improve our understanding of greenhouse gas dynamics of managed ecosystems such as grasslands, we not only need to investigate the effects of management (e.g., grass cuts) and weather events (e.g., rainy days) on carbon dioxide fluxes, but also need to increase the time resolution of our measurements. Thus, for the first time, we assessed respiration and assimilation fluxes with high time resolution (5Hz) stable isotope measurements at an intensively managed farmland in Switzerland (Chamau, 400m ASL). Two different methods were used to quantify fluxes of carbon dioxide and associated fluxes of stable carbon isotopes: (1) the flux gradient method, and (2) the eddy covariance method. During a week long intensive measurement campaign, we (1) measured mixing ratios of carbon dioxide isotopomers (12C16O2, 12C16O18O, 13C16O2) with a Quantum Cascade Laser (QCL, Aerodyne Inc.) spectroscope and (2) collected air samples for isotope analyses (13C/12C) and (18O/16O) of carbon dioxide by Isotope Ratio Mass Spectrometry (IRMS, Finnigan) every two hours, concurrently along a height profile (z = 0.05; 0.10; 0.31; 2.15m). In the following week, the QCL setup was used for closed-path eddy covariance flux measurement of the carbon dioxide isotopomers, with the air inlet located next to an open-path Infra Red Gas Analyzers (IRGA, LiCor 7500) used simultaneously for carbon dioxide measurements. During this second week, an area of grass inside the footprint was cut and harvested after several days. The first results of in-field continuous QCL measurements of carbon dioxide mixing ratios and their stable isotopic ratios show good agreement with IRGA measurements and isotope analysis of flask samples by IRMS. Thus, QCL spectroscopy is a very promising tool for stable isotope flux investigations.

  11. Automatically-generated rectal dose constraints in intensity-modulated radiation therapy for prostate cancer

    NASA Astrophysics Data System (ADS)

    Hwang, Taejin; Kim, Yong Nam; Kim, Soo Kon; Kang, Sei-Kwon; Cheong, Kwang-Ho; Park, Soah; Yoon, Jai-Woong; Han, Taejin; Kim, Haeyoung; Lee, Meyeon; Kim, Kyoung-Joo; Bae, Hoonsik; Suh, Tae-Suk

    2015-06-01

    The dose constraint during prostate intensity-modulated radiation therapy (IMRT) optimization should be patient-specific for better rectum sparing. The aims of this study are to suggest a novel method for automatically generating a patient-specific dose constraint by using an experience-based dose volume histogram (DVH) of the rectum and to evaluate the potential of such a dose constraint qualitatively. The normal tissue complication probabilities (NTCPs) of the rectum with respect to V %ratio in our study were divided into three groups, where V %ratio was defined as the percent ratio of the rectal volume overlapping the planning target volume (PTV) to the rectal volume: (1) the rectal NTCPs in the previous study (clinical data), (2) those statistically generated by using the standard normal distribution (calculated data), and (3) those generated by combining the calculated data and the clinical data (mixed data). In the calculated data, a random number whose mean value was on the fitted curve described in the clinical data and whose standard deviation was 1% was generated by using the `randn' function in the MATLAB program and was used. For each group, we validated whether the probability density function (PDF) of the rectal NTCP could be automatically generated with the density estimation method by using a Gaussian kernel. The results revealed that the rectal NTCP probability increased in proportion to V %ratio , that the predictive rectal NTCP was patient-specific, and that the starting point of IMRT optimization for the given patient might be different. The PDF of the rectal NTCP was obtained automatically for each group except that the smoothness of the probability distribution increased with increasing number of data and with increasing window width. We showed that during the prostate IMRT optimization, the patient-specific dose constraints could be automatically generated and that our method could reduce the IMRT optimization time as well as maintain the IMRT plan quality.

  12. Resonance Scattering of Fe XVII X-ray and EUV Lines

    NASA Technical Reports Server (NTRS)

    Bhatia, A. K.; Saba, J. L. R.; Fisher, Richard R. (Technical Monitor)

    2001-01-01

    Over the years a number of calculations have been carried out to derive intensities of various X-ray and EUV lines in Fe XVII to compare with observed spectra. The predicted intensities have not agreed with solar observations, particularly for the line at 1.5.02 Angstroms; resonance scattering has been suggested as the source for much of the disagreement. The atomic data calculated earlier used seven configurations having n=3 orbitals and the scattering calculations were carried out only for incident energies above the threshold of the highest fine-structure level. These calculations have now been extended to thirteen configurations having n=4 orbitals and the scattering calculations are carried out below as well as above the threshold of the highest fine structure level. These improved calculations of Fe XVII change the intensity ratios compared to those obtained earlier, bringing the optically thin F(15.02)/F(16.78) ratio and several other ratios closer to the observed values. However, some disagreement with the solar observations still persists, even thought the agreement of the presently calculated optically thin F(15.02)/F(15.26) ratio with the experimental results of Brown et al. (1998) and Laming et al. (2000) has improved. Some of the remaining discrepancy is still thought to be the effect of opacity, which is consistent with expected physical conditions for solar sources. EUV intensity ratios are also calculated and compared with observations. Level populations and intensity ratios are calculated, as a function of column density of Fe XVII, in the slab and cylindrical geometries. As found previously, the predicted intensities for the resonance lines at 15.02 and 15.26 Angstroms exhibit initial increases in flux relative to the forbidden line at 17.10 Angstroms and the resonance line at 16.78 Angstroms as optical thickness increases. The same behavior is predicted for the lines at 12.262 and 12.122 Angstroms. Predicted intensities for some of the allowed EUV lines are also affected by opacity.

  13. [The H+/e- ratio in the photosynthetic electron transport chain].

    PubMed

    Ivanov, B N; Shmeleva, V L; Ovchinnikova, V I

    1983-06-01

    The number of protons adsorbed by tylakoids during one electron passage along the photosynthetic electron transport chain (i.e. the H+/e- ratio) was measured in isolated pea chloroplasts upon continuous illumination. Methylviologen was used as electron acceptor on the reducing side of PS I. It was found that at pH 6.0 upon illumination with red light (lambda greater than 620 nm) at an intensity of 2 . 10(5) erg/cm2 . s ("intensive" light) the H+/e- ratio is equal to 3. Upon illumination of dark-adapted chloroplasts with a "weak" light (900 erg/cm2 . s) the H+/e- ratio is equal to 2. Upon illumination of the chloroplasts with a "weak" after "intensive" light the value of this ratio is close to 3. Azide when added to the reaction mixture may interfere with the accuracy of measurements of the value of the H+/e- ratio by affecting proton exchange. Based on the changes in the H+/e- ratio induced by illumination it was assumed that at saturating intensity of the illuminating light the electron transport chain passes into a so-called "light" state when the mechanisms of proton-electron coupling differing from those of rare electron transfer ("weak" light, flashes) are triggered on. At pH 6.0 the "light" state of the electron transport chain is maintained for some time in the dark.

  14. CdSe/ZnS quantum dots conjugated with a fluorescein derivative: a FRET-based pH sensor for physiological alkaline conditions.

    PubMed

    Kurabayashi, Tomokazu; Funaki, Nayuta; Fukuda, Takeshi; Akiyama, Shinnosuke; Suzuki, Miho

    2014-01-01

    Dual pH-dependent fluorescence peaks from a semiconductor quantum dot (QD) and a pH-dependent fluorescent dye can be measured by irradiating with a single wavelength light, and the pH can be estimated from the ratio of the fluorescent intensity of the two peaks. In this work, ratiometric pH sensing was achieved in an aqueous environment by a fluorescent CdSe/ZnS QD appended with a pH-sensitive organic dye, based on fluorescence resonance energy transfer (FRET). By functionalizing the CdSe/ZnS QD with 5-(and 6)-carboxynaphthofluorescein succinimidyl ester as a pH-dependent fluorescent dye, we succeeded in fabricating sensitive nanocomplexes with a linear response to a broad range of physiological pH levels (7.5-9.5) when excited at 450 nm. We found that a purification process is important for increasing the high-fluorescence intensity ratio of a ratiometric fluorescence pH-sensor, and the fluorescence intensity ratio was improved up to 1.0 at pH 8.0 after the purification process to remove unreacted CdSe/ZnS QDs even though the fluorescence of the dye could not be observed without the purification process. The fluorescence intensity ratio corresponds to the fluorescence intensity of the dye, and this fluorescent dye exhibited pH-dependent fluorescence intensity changes. These facts indicate that the fluorescence intensity ratio linearly increased with increasing pH value of the buffer solution containing the QD and the dye. The FRET efficiencies changed from 0.3 (pH 7.5) to 6.2 (pH 9.5).

  15. Intensivist physician staffing and the process of care in academic medical centres

    PubMed Central

    Kahn, Jeremy M; Brake, Helga; Steinberg, Kenneth P

    2007-01-01

    Background Although intensivist physician staffing is associated with improved outcomes in critical care, little is known about the mechanism leading to this observation. Objective To determine the relationship between intensivist staffing and select process‐based quality indicators in the intensive care unit. Research design Retrospective cohort study in 29 academic hospitals participating in the University HealthSystem Consortium Mechanically Ventilated Patient Bundle Benchmarking Project. Patients 861 adult patients receiving prolonged mechanical ventilation in an intensive care unit. Results Patient‐level information on physician staffing and process‐of‐care quality indicators were collected on day 4 of mechanical ventilation. By day 4, 668 patients received care under a high intensity staffing model (primary intensivist care or mandatory consult) and 193 patients received care under a low intensity staffing model (optional consultation or no intensivist). Among eligible patients, those receiving care under a high intensity staffing model were more likely to receive prophylaxis for deep vein thrombosis (risk ratio 1.08, 95% CI 1.00 to 1.17), stress ulcer prophylaxis (risk ratio 1.10, 95% CI 1.03 to 1.18), a spontaneous breathing trial (risk ratio 1.37, 95% CI 0.97 to 1.94), interruption of sedation (risk ratio 1.64, 95% CI 1.13 to 2.38) and intensive insulin treatment (risk ratio 1.40, 95% CI 1.18 to 1.79) on day 4 of mechanical ventilation. Models accounting for clustering by hospital produced similar estimates of the staffing effect, except for prophylaxis against thrombosis and stress ulcers. Conclusions High intensity physician staffing is associated with increased use of evidence‐based quality indictors in patients receiving mechanical ventilation. PMID:17913772

  16. Effects of Education and Income on Treatment and Outcome in Patients With Acute Myeloid Leukemia in a Tax-Supported Health Care System: A National Population-Based Cohort Study.

    PubMed

    Østgård, Lene Sofie Granfeldt; Nørgaard, Mette; Medeiros, Bruno C; Friis, Lone Smidstrup; Schoellkopf, Claudia; Severinsen, Marianne Tang; Marcher, Claus Werenberg; Nørgaard, Jan Maxwell

    2017-11-10

    Purpose Previous US studies have shown that socioeconomic status (SES) affects survival in acute myeloid leukemia (AML). However, no large study has investigated the association between education or income and clinical characteristics, treatment, and outcome in AML. Methods To investigate the effects of education and income in a tax-supported health care system, we conducted a population-based study using individual-level SES and clinical data on all Danish patients with AML (2000 to 2014). We compared treatment intensity, allogeneic transplantation, and response rates by education and income level using logistic regression (odds ratios). We used Cox regression (hazard ratios [HRs]) to compare survival, adjusting for age, sex, SES, and clinical prognostic markers. Results Of 2,992 patients, 1,588 (53.1%) received intensive chemotherapy. Compared with low-education patients, highly educated patients more often received allogeneic transplantation (16.3% v 8.7%). In intensively treated patients younger than 60 years of age, increased mortality was observed in those with lower and medium education (1-year survival, 66.7%; adjusted HR, 1.47; 95% CI, 1.11 to 1.93; and 1-year survival, 67.6%; adjusted HR, 1.55; CI, 1.21 to 1.98, respectively) compared with higher education (1-year survival, 76.9%). Over the study period, 5-year survival improvements were limited to high-education patients (from 39% to 58%), increasing the survival gap between groups. In older patients, low-education patients received less intensive therapy (30% v 48%; adjusted odds ratio, 0.65; CI, 0.44 to 0.98) compared with high-education patients; however, remission rates and survival were not affected in those intensively treated. Income was not associated with therapy intensity, likelihood of complete remission, or survival (high income: adjusted HR, 1.0; medium income: adjusted HR, 0.96; 95% CI, 0.82 to 1.12; low income: adjusted HR, 1.06; CI, .88 to 1.27). Conclusion In a universal health care system, education level, but not income, affects transplantation rates and survival in younger patients with AML. Importantly, recent survival improvement has exclusively benefitted highly educated patients.

  17. Emission intensities and line ratios from a fast neutral helium beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, J-W.; Craig, D.; Fiksel, G.

    2007-08-15

    The emission intensities and line ratios from a fast neutral helium beam is investigated in the Madison Symmetric Torus (MST) [R. N. Dexter, D. W. Kerst, T. W. Lovell, S. C. Prager, and J. C. Sprott, Fusion Technol. 19, 131 1991]. Predicted He I line intensities and line ratios from a recently developed collisional-radiative model are compared with experiment. The intensity of singlet lines comes mostly (>95%) from the contribution of the ground state population and is very weakly dependent on the initial metastable fraction at the observation point in the plasma core. On the other hand, the intensity ofmore » triplet lines is strongly affected by the local metastable state (2{sup 1}S and 2{sup 3}S) populations and the initial metastable fraction plays an important role in determining line intensities. The fraction of local metastable states can only be estimated by making use of electron temperature (T{sub e}), electron density (n{sub e}), and effective ion charge (Z{sub eff}) profiles as inputs to the population balance equations. This leads triplet lines to be unusable for the investigation of their local plasma parameter dependence. The ratio of singlet lines at 667.8 nm and 492.2 nm (I{sub 667}/I{sub 492}) as well as the ratio of 667.8 nm and 501.6 nm lines (I{sub 667}/I{sub 501}) has been investigated for the dependence on T{sub e} and n{sub e} both theoretically and experimentally. I{sub 667}/I{sub 492} shows strong dependence on n{sub e} with weak sensitivity to T{sub e}. Measurements and predictions agree quantitatively within a factor of 2. There has been no ratio of singlet lines identified to have strong enough T{sub e} dependence yet. The ratios are expected to be reasonably insensitive to the variation of Z{sub eff}.« less

  18. All-optical universal logic gates on nonlinear multimode interference coupler using tunable input intensity

    NASA Astrophysics Data System (ADS)

    Tajaldini, Mehdi; Jafri, Mohd Zubir Mat

    2015-04-01

    The theory of Nonlinear Modal Propagation Analysis Method (NMPA) have shown significant features of nonlinear multimode interference (MMI) coupler with compact dimension and when launched near the threshold of nonlinearity. Moreover, NMPA have the potential to allow studying the nonlinear MMI based the modal interference to explorer the phenomenon that what happen due to the natural of multimode region. Proposal of all-optical switch based NMPA has approved its capability to achieving the all-optical gates. All-optical gates have attracted increasing attention due to their practical utility in all-optical signal processing networks and systems. Nonlinear multimode interference devices could apply as universal all-optical gates due to significant features that NMPA introduce them. In this Paper, we present a novel Ultra-compact MMI coupler based on NMPA method in low intensity compared to last reports either as a novel design method and potential application for optical NAND, NOR as universal gates on single structure for Boolean logic signal processing devices and optimize their application via studding the contrast ratio between ON and OFF as a function of output width. We have applied NMPA for several applications so that the miniaturization in low nonlinear intensities is their main purpose.

  19. Comparison of Total Evaporation (TE) and Direct Total Evaporation (DTE) methods in TIMS by using NBL CRMs

    NASA Astrophysics Data System (ADS)

    Hasözbek, Altug; Mathew, Kattathu; Wegener, Michael

    2013-04-01

    The total evaporation (TE) is a well-established analytical method for safeguards measurement of uranium and plutonium isotope-amount ratios using the thermal ionization mass spectrometry (TIMS). High accuracy and precision isotopic measurements find many applications in nuclear safeguards, for e.g. assay measurements using isotope dilution mass spectrometry. To achieve high accuracy and precision in TIMS measurements, mass dependent fractionation effects are minimized by either the measurement technique or changes in the hardware components that are used to control sample heating and evaporation process. At NBL, direct total evaporation (DTE) method on the modified MAT261 instrument, uses the data system to read the ion signal intensity and its difference from a pre-determined target intensity, is used to control the incremental step at which the evaporation filament is heated. The feedback and control is achieved by proprietary hardware from SPECTROMAT that uses an analog regulator in the filament power supply with direct feedback of the detector intensity. Compared to traditional TE method on this instrument, DTE provides better precision (relative standard deviation, expressed as a percent) and accuracy (relative difference, expressed as a percent) of 0.05 to 0.08 % for low enriched and high enriched NBL uranium certified reference materials.

  20. Mortality in former Olympic athletes: retrospective cohort analysis

    PubMed Central

    Zwiers, R; Zantvoord, F W A; van Bodegom, D; van der Ouderaa, F J G; Westendorp, R G J

    2012-01-01

    Objective To assess the mortality risk in subsequent years (adjusted for year of birth, nationality, and sex) of former Olympic athletes from disciplines with different levels of exercise intensity. Design Retrospective cohort study. Setting Former Olympic athletes. Participants 9889 athletes (with a known age at death) who participated in the Olympic Games between 1896 and 1936, representing 43 types of disciplines with different levels of cardiovascular, static, and dynamic intensity exercise; high or low risk of bodily collision; and different levels of physical contact. Main outcome measure All cause mortality. Results Hazard ratios for mortality among athletes from disciplines with moderate cardiovascular intensity (1.01, 95% confidence interval 0.96 to 1.07) or high cardiovascular intensity (0.98, 0.92 to 1.04) were similar to those in athletes from disciplines with low cardiovascular intensity. The underlying static and dynamic components in exercise intensity showed similar non-significant results. Increased mortality was seen among athletes from disciplines with a high risk of bodily collision (hazard ratio 1.11, 1.06 to 1.15) and with high levels of physical contact (1.16, 1.11 to 1.22). In a multivariate analysis, the effect of high cardiovascular intensity remained similar (hazard ratio 1.05, 0.89 to 1.25); the increased mortality associated with high physical contact persisted (hazard ratio 1.13, 1.06 to 1.21), but that for bodily collision became non-significant (1.03, 0.98 to 1.09) as a consequence of its close relation with physical contact. Conclusions Among former Olympic athletes, engagement in disciplines with high intensity exercise did not bring a survival benefit compared with disciplines with low intensity exercise. Those who engaged in disciplines with high levels of physical contact had higher mortality than other Olympians later in life. PMID:23241269

  1. Development of CO2 laser dispersion interferometer with photoelastic modulator

    NASA Astrophysics Data System (ADS)

    Akiyama, T.; Kawahata, K.; Okajima, S.; Nakayama, K.

    2010-10-01

    A dispersion interferometer is one of the promising methods of the electron density measurement on large and high density fusion devices. This paper describes development of a CO2 laser dispersion interferometer with a photoelastic modulator for phase modulation. In order to make the dispersion interferometer free from variations of the detected intensity, a new phase extraction method is introduced: The phase shift is evaluated from a ratio of amplitudes of the fundamental and the second harmonics of the phase modulation frequency in the detected interference signal. The proof-of-principle experiments demonstrate the feasibility of this method.

  2. Development of CO2 laser dispersion interferometer with photoelastic modulator.

    PubMed

    Akiyama, T; Kawahata, K; Okajima, S; Nakayama, K

    2010-10-01

    A dispersion interferometer is one of the promising methods of the electron density measurement on large and high density fusion devices. This paper describes development of a CO(2) laser dispersion interferometer with a photoelastic modulator for phase modulation. In order to make the dispersion interferometer free from variations of the detected intensity, a new phase extraction method is introduced: The phase shift is evaluated from a ratio of amplitudes of the fundamental and the second harmonics of the phase modulation frequency in the detected interference signal. The proof-of-principle experiments demonstrate the feasibility of this method.

  3. Learning-based 3T brain MRI segmentation with guidance from 7T MRI labeling.

    PubMed

    Deng, Minghui; Yu, Renping; Wang, Li; Shi, Feng; Yap, Pew-Thian; Shen, Dinggang

    2016-12-01

    Segmentation of brain magnetic resonance (MR) images into white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF) is crucial for brain structural measurement and disease diagnosis. Learning-based segmentation methods depend largely on the availability of good training ground truth. However, the commonly used 3T MR images are of insufficient image quality and often exhibit poor intensity contrast between WM, GM, and CSF. Therefore, they are not ideal for providing good ground truth label data for training learning-based methods. Recent advances in ultrahigh field 7T imaging make it possible to acquire images with excellent intensity contrast and signal-to-noise ratio. In this paper, the authors propose an algorithm based on random forest for segmenting 3T MR images by training a series of classifiers based on reliable labels obtained semiautomatically from 7T MR images. The proposed algorithm iteratively refines the probability maps of WM, GM, and CSF via a cascade of random forest classifiers for improved tissue segmentation. The proposed method was validated on two datasets, i.e., 10 subjects collected at their institution and 797 3T MR images from the Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset. Specifically, for the mean Dice ratio of all 10 subjects, the proposed method achieved 94.52% ± 0.9%, 89.49% ± 1.83%, and 79.97% ± 4.32% for WM, GM, and CSF, respectively, which are significantly better than the state-of-the-art methods (p-values < 0.021). For the ADNI dataset, the group difference comparisons indicate that the proposed algorithm outperforms state-of-the-art segmentation methods. The authors have developed and validated a novel fully automated method for 3T brain MR image segmentation. © 2016 American Association of Physicists in Medicine.

  4. Learning-based 3T brain MRI segmentation with guidance from 7T MRI labeling.

    PubMed

    Deng, Minghui; Yu, Renping; Wang, Li; Shi, Feng; Yap, Pew-Thian; Shen, Dinggang

    2016-12-01

    Segmentation of brain magnetic resonance (MR) images into white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF) is crucial for brain structural measurement and disease diagnosis. Learning-based segmentation methods depend largely on the availability of good training ground truth. However, the commonly used 3T MR images are of insufficient image quality and often exhibit poor intensity contrast between WM, GM, and CSF. Therefore, they are not ideal for providing good ground truth label data for training learning-based methods. Recent advances in ultrahigh field 7T imaging make it possible to acquire images with excellent intensity contrast and signal-to-noise ratio. In this paper, the authors propose an algorithm based on random forest for segmenting 3T MR images by training a series of classifiers based on reliable labels obtained semiautomatically from 7T MR images. The proposed algorithm iteratively refines the probability maps of WM, GM, and CSF via a cascade of random forest classifiers for improved tissue segmentation. The proposed method was validated on two datasets, i.e., 10 subjects collected at their institution and 797 3T MR images from the Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset. Specifically, for the mean Dice ratio of all 10 subjects, the proposed method achieved 94.52% ± 0.9%, 89.49% ± 1.83%, and 79.97% ± 4.32% for WM, GM, and CSF, respectively, which are significantly better than the state-of-the-art methods (p-values < 0.021). For the ADNI dataset, the group difference comparisons indicate that the proposed algorithm outperforms state-of-the-art segmentation methods. The authors have developed and validated a novel fully automated method for 3T brain MR image segmentation.

  5. Examining the canopy interception at a forest field site using cosmic-ray neutron detection

    NASA Astrophysics Data System (ADS)

    Andreasen, M.; Looms, M.; Christiansen, J. R.; Sonnenborg, T. O.; Stisen, S.; Jensen, K. H.

    2017-12-01

    Canopy interception, the amount of precipitation captured by the surface of plants and trees, is a key component of the water cycle as it constrains the water flux to the ground below vegetation. Forests have especially high interception capacities and therefore the interception loss often forms a considerable part of the total evapotranspiration. The canopy interception capacity is dependent on the size and structure of the vegetation, and the interception loss can vary substantial in time and space. Measuring the canopy interception loss directly is challenging and current methodologies only represent small areas and rely on indirect approaches. Improving methods to estimate canopy interception loss directly will forward the basic understanding of how vegetation structure interacts with the water cycle and hence prediction of evapotranspiration. The intensity of low-energy neutrons produced by cosmic-rays, measured above the ground surface, is sensitive to the hydrogen content in the upper decimeters of the ground and hence the soil moisture content from a radius of hundreds of meters in the horizontal direction. In order to advance the cosmic-ray neutron (CRN) soil moisture method and extend the application of the CRN method more research has recently focused on the signal of other hydrogen pools on the neutron intensity (e.g., vegetation and canopy interception). A recent study, based on neutron transport modeling, found that the ground level thermal neutron intensity (energy < 1 eV), and as a consequence also the thermal-to-epithermal neutron (T/E) ratio (epithermal energy > 1 eV), increased with increasing canopy interception. In this study, we test whether CRN measurements can be used to provide a direct measure of the canopy interception. Four sets of CR2000/B systems were installed below the canopy in an oak forest stand in Denmark. Each system holds a bare (primarily measuring thermal neutrons) and a moderated detector (primarily measuring epithermal neutrons). The measured T/E ratios are compared to independent canopy interception measurements, obtained from throughfall and precipitation measurements. Furthermore, T/E ratios are related to measurements from leaf wetness sensors, CRN soil moisture estimates, and the biomass density in the canopy derived from a mobile terrestrial laser scanner.

  6. Theoretical and Experimental Study on Wide Range Optical Fiber Turbine Flow Sensor.

    PubMed

    Du, Yuhuan; Guo, Yingqing

    2016-07-15

    In this paper, a novel fiber turbine flow sensor was proposed and demonstrated for liquid measurement with optical fiber, using light intensity modulation to measure the turbine rotational speed for converting to flow rate. The double-circle-coaxial (DCC) fiber probe was introduced in frequency measurement for the first time. Through the divided ratio of two rings light intensity, the interference in light signals acquisition can be eliminated. To predict the characteristics between the output frequency and flow in the nonlinear range, the turbine flow sensor model was built. Via analyzing the characteristics of turbine flow sensor, piecewise linear equations were achieved in expanding the flow measurement range. Furthermore, the experimental verification was tested. The results showed that the flow range ratio of DN20 turbine flow sensor was improved 2.9 times after using piecewise linear in the nonlinear range. Therefore, combining the DCC fiber sensor and piecewise linear method, it can be developed into a strong anti-electromagnetic interference(anti-EMI) and wide range fiber turbine flowmeter.

  7. Theoretical and Experimental Study on Wide Range Optical Fiber Turbine Flow Sensor

    PubMed Central

    Du, Yuhuan; Guo, Yingqing

    2016-01-01

    In this paper, a novel fiber turbine flow sensor was proposed and demonstrated for liquid measurement with optical fiber, using light intensity modulation to measure the turbine rotational speed for converting to flow rate. The double-circle-coaxial (DCC) fiber probe was introduced in frequency measurement for the first time. Through the divided ratio of two rings light intensity, the interference in light signals acquisition can be eliminated. To predict the characteristics between the output frequency and flow in the nonlinear range, the turbine flow sensor model was built. Via analyzing the characteristics of turbine flow sensor, piecewise linear equations were achieved in expanding the flow measurement range. Furthermore, the experimental verification was tested. The results showed that the flow range ratio of DN20 turbine flow sensor was improved 2.9 times after using piecewise linear in the nonlinear range. Therefore, combining the DCC fiber sensor and piecewise linear method, it can be developed into a strong anti-electromagnetic interference(anti-EMI) and wide range fiber turbine flowmeter. PMID:27428976

  8. 1 Tbit/inch2 Recording in Angular-Multiplexing Holographic Memory with Constant Signal-to-Scatter Ratio Schedule

    NASA Astrophysics Data System (ADS)

    Hosaka, Makoto; Ishii, Toshiki; Tanaka, Asato; Koga, Shogo; Hoshizawa, Taku

    2013-09-01

    We developed an iterative method for optimizing the exposure schedule to obtain a constant signal-to-scatter ratio (SSR) to accommodate various recording conditions and achieve high-density recording. 192 binary images were recorded in the same location of a medium in approximately 300×300 µm2 using an experimental system embedded with a blue laser diode with a 405 nm wavelength and an objective lens with a 0.85 numerical aperture. The recording density of this multiplexing corresponds to 1 Tbit/in.2. The recording exposure time was optimized through the iteration of a three-step sequence consisting of total reproduced intensity measurement, target signal calculation, and recording energy density calculation. The SSR of pages recorded with this method was almost constant throughout the entire range of the reference beam angle. The signal-to-noise ratio of the sampled pages was over 2.9 dB, which is higher than the reproducible limit of 1.5 dB in our experimental system.

  9. [Quantitative Analysis of Heavy Metals in Water with LIBS Based on Signal-to-Background Ratio].

    PubMed

    Hu, Li; Zhao, Nan-jing; Liu, Wen-qing; Fang, Li; Zhang, Da-hai; Wang, Yin; Meng, De Shuo; Yu, Yang; Ma, Ming-jun

    2015-07-01

    There are many influence factors in the precision and accuracy of the quantitative analysis with LIBS technology. According to approximately the same characteristics trend of background spectrum and characteristic spectrum along with the change of temperature through in-depth analysis, signal-to-background ratio (S/B) measurement and regression analysis could compensate the spectral line intensity changes caused by system parameters such as laser power, spectral efficiency of receiving. Because the measurement dates were limited and nonlinear, we used support vector machine (SVM) for regression algorithm. The experimental results showed that the method could improve the stability and the accuracy of quantitative analysis of LIBS, and the relative standard deviation and average relative error of test set respectively were 4.7% and 9.5%. Data fitting method based on signal-to-background ratio(S/B) is Less susceptible to matrix elements and background spectrum etc, and provides data processing reference for real-time online LIBS quantitative analysis technology.

  10. Quantitative stress measurement of elastic deformation using mechanoluminescent sensor: An intensity ratio model

    NASA Astrophysics Data System (ADS)

    Cai, Tao; Guo, Songtao; Li, Yongzeng; Peng, Di; Zhao, Xiaofeng; Liu, Yingzheng

    2018-04-01

    The mechanoluminescent (ML) sensor is a newly developed non-invasive technique for stress/strain measurement. However, its application has been mostly restricted to qualitative measurement due to the lack of a well-defined relationship between ML intensity and stress. To achieve accurate stress measurement, an intensity ratio model was proposed in this study to establish a quantitative relationship between the stress condition and its ML intensity in elastic deformation. To verify the proposed model, experiments were carried out on a ML measurement system using resin samples mixed with the sensor material SrAl2O4:Eu2+, Dy3+. The ML intensity ratio was found to be dependent on the applied stress and strain rate, and the relationship acquired from the experimental results agreed well with the proposed model. The current study provided a physical explanation for the relationship between ML intensity and its stress condition. The proposed model was applicable in various SrAl2O4:Eu2+, Dy3+-based ML measurement in elastic deformation, and could provide a useful reference for quantitative stress measurement using the ML sensor in general.

  11. A level set method for cupping artifact correction in cone-beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Shipeng; Li, Haibo; Ge, Qi

    2015-08-15

    Purpose: To reduce cupping artifacts and improve the contrast-to-noise ratio in cone-beam computed tomography (CBCT). Methods: A level set method is proposed to reduce cupping artifacts in the reconstructed image of CBCT. The authors derive a local intensity clustering property of the CBCT image and define a local clustering criterion function of the image intensities in a neighborhood of each point. This criterion function defines an energy in terms of the level set functions, which represent a segmentation result and the cupping artifacts. The cupping artifacts are estimated as a result of minimizing this energy. Results: The cupping artifacts inmore » CBCT are reduced by an average of 90%. The results indicate that the level set-based algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. Conclusions: The proposed method focuses on the reconstructed image without requiring any additional physical equipment, is easily implemented, and provides cupping correction through a single-scan acquisition. The experimental results demonstrate that the proposed method successfully reduces the cupping artifacts.« less

  12. Label-free imaging and spectroscopy for early detection of cervical cancer.

    PubMed

    Jing, Yueyue; Wang, Yulan; Wang, Xinyi; Song, Chuan; Ma, Jiong; Xie, Yonghui; Fei, Yiyan; Zhang, Qinghua; Mi, Lan

    2018-05-01

    The label-free imaging and spectroscopy method was studied on cervical unstained tissue sections obtained from 36 patients. The native fluorescence spectra of tissues are analyzed by the optical redox ratio (ORR), which is defined as fluorescence intensity ratio between NADH and FAD, and indicates the metabolism change with the cancer development. The ORRs of normal tissues are consistently higher than those of precancer or cancerous tissues. A criterion line of ORR at 5.0 can be used to discriminate cervical precancer/cancer from normal tissues. The sensitivity and specificity of the native fluorescence spectroscopy method for cervical cancer diagnosis are determined as 100% and 91%. Moreover, the native fluorescence spectroscopy study is much more sensitive on the healthy region of cervical precancer/cancer patients compared with the traditional clinical staining method. The results suggest label-free imaging and spectroscopy is a fast, highly sensitive and specific method on the detection of cervical cancer. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Clinical Benefits, Costs, and Cost-Effectiveness of Neonatal Intensive Care in Mexico

    PubMed Central

    Profit, Jochen; Lee, Diana; Zupancic, John A.; Papile, LuAnn; Gutierrez, Cristina; Goldie, Sue J.; Gonzalez-Pier, Eduardo; Salomon, Joshua A.

    2010-01-01

    Background Neonatal intensive care improves survival, but is associated with high costs and disability amongst survivors. Recent health reform in Mexico launched a new subsidized insurance program, necessitating informed choices on the different interventions that might be covered by the program, including neonatal intensive care. The purpose of this study was to estimate the clinical outcomes, costs, and cost-effectiveness of neonatal intensive care in Mexico. Methods and Findings A cost-effectiveness analysis was conducted using a decision analytic model of health and economic outcomes following preterm birth. Model parameters governing health outcomes were estimated from Mexican vital registration and hospital discharge databases, supplemented with meta-analyses and systematic reviews from the published literature. Costs were estimated on the basis of data provided by the Ministry of Health in Mexico and World Health Organization price lists, supplemented with published studies from other countries as needed. The model estimated changes in clinical outcomes, life expectancy, disability-free life expectancy, lifetime costs, disability-adjusted life years (DALYs), and incremental cost-effectiveness ratios (ICERs) for neonatal intensive care compared to no intensive care. Uncertainty around the results was characterized using one-way sensitivity analyses and a multivariate probabilistic sensitivity analysis. In the base-case analysis, neonatal intensive care for infants born at 24–26, 27–29, and 30–33 weeks gestational age prolonged life expectancy by 28, 43, and 34 years and averted 9, 15, and 12 DALYs, at incremental costs per infant of US$11,400, US$9,500, and US$3,000, respectively, compared to an alternative of no intensive care. The ICERs of neonatal intensive care at 24–26, 27–29, and 30–33 weeks were US$1,200, US$650, and US$240, per DALY averted, respectively. The findings were robust to variation in parameter values over wide ranges in sensitivity analyses. Conclusions Incremental cost-effectiveness ratios for neonatal intensive care imply very high value for money on the basis of conventional benchmarks for cost-effectiveness analysis. Please see later in the article for the Editors' Summary PMID:21179496

  14. Effects of Molar Ratios and Sintering Times on Crystal Structures and Surface Morphology of Nd1+xFeO3 Oxide Alloy Prepared by using Solid Reaction Method

    NASA Astrophysics Data System (ADS)

    Sujiono, E. H.; Agus, J.; Samnur, S.; Triyana, K.

    2018-05-01

    The effects of molar ratios and sintering times on crystal structures and surface morphology on NdFeO3 oxide alloy have been studied. NdFeO3 oxide alloy formed by chemical preparation with solid reaction method using raw oxide Fe2O3 (99.9 %) and Nd2O3 (99.9 %) powders. In this article we reported the effects of molar ratios x = (–0.1, –0.2 and –0.3) and sintering times for 15 h and 20 h on crystal structures and surface morphology of Nd1+xFeO3 synthesized by solid-state reaction method. The results indicate that variation of molar ratio and sintering time has influenced the FWHM, crystalline size and grain size. The Nd1+xFeO3 have a major phase is NdFeO3, and other minor phases are Fe2O3, Nd2O3 and Nd(OH)3. The dominant intensity of hkl (121) with a value in FWHM, crystallite size, and grain size an indication the results will be applied as a gas sensor material as the focus of the further study.

  15. Inertia-gravity wave radiation from the elliptical vortex in the f-plane shallow water system

    NASA Astrophysics Data System (ADS)

    Sugimoto, Norihiko

    2017-04-01

    Inertia-gravity wave (IGW) radiation from the elliptical vortex is investigated in the f-plane shallow water system. The far field of IGW is analytically derived for the case of an almost circular Kirchhoff vortex with a small aspect ratio. Cyclone-anticyclone asymmetry appears at finite values of the Rossby number (Ro) caused by the source originating in the Coriolis acceleration. While the intensity of IGWs from the cyclone monotonically decreases as f increases, that from the anticyclone increases as f increases for relatively smaller f and has a local maximum at intermediate f. A numerical experiment is conducted on a model using a spectral method in an unbounded domain. The numerical results agree quite well with the analytical ones for elliptical vortices with small aspect ratios, implying that the derived analytical forms are useful for the verification of the numerical model. For elliptical vortices with larger aspect ratios, however, significant deviation from the analytical estimates appears. The intensity of IGWs radiated in the numerical simulation is larger than that estimated analytically. The reason is that the source of IGWs is amplified during the time evolution because the shape of the vortex changes from ideal ellipse to elongated with filaments. Nevertheless, cyclone-anticyclone asymmetry similar to the analytical estimate appears in all the range of aspect ratios, suggesting that this asymmetry is a robust feature.

  16. Effect of the Hartmann number on phase separation controlled by magnetic field for binary mixture system with large component ratio

    NASA Astrophysics Data System (ADS)

    Heping, Wang; Xiaoguang, Li; Duyang, Zang; Rui, Hu; Xingguo, Geng

    2017-11-01

    This paper presents an exploration for phase separation in a magnetic field using a coupled lattice Boltzmann method (LBM) with magnetohydrodynamics (MHD). The left vertical wall was kept at a constant magnetic field. Simulations were conducted by the strong magnetic field to enhance phase separation and increase the size of separated phases. The focus was on the effect of magnetic intensity by defining the Hartmann number (Ha) on the phase separation properties. The numerical investigation was carried out for different governing parameters, namely Ha and the component ratio of the mixed liquid. The effective morphological evolutions of phase separation in different magnetic fields were demonstrated. The patterns showed that the slant elliptical phases were created by increasing Ha, due to the formation and increase of magnetic torque and force. The dataset was rearranged for growth kinetics of magnetic phase separation in a plot by spherically averaged structure factor and the ratio of separated phases and total system. The results indicate that the increase in Ha can increase the average size of separated phases and accelerate the spinodal decomposition and domain growth stages. Specially for the larger component ratio of mixed phases, the separation degree was also significantly improved by increasing magnetic intensity. These numerical results provide guidance for setting the optimum condition for the phase separation induced by magnetic field.

  17. Quantitative analysis of comparative genomic hybridization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manoir, S. du; Bentz, M.; Joos, S.

    1995-01-01

    Comparative genomic hybridization (CGH) is a new molecular cytogenetic method for the detection of chromosomal imbalances. Following cohybridization of DNA prepared from a sample to be studied and control DNA to normal metaphase spreads, probes are detected via different fluorochromes. The ratio of the test and control fluorescence intensities along a chromosome reflects the relative copy number of segments of a chromosome in the test genome. Quantitative evaluation of CGH experiments is required for the determination of low copy changes, e.g., monosomy or trisomy, and for the definition of the breakpoints involved in unbalanced rearrangements. In this study, a programmore » for quantitation of CGH preparations is presented. This program is based on the extraction of the fluorescence ratio profile along each chromosome, followed by averaging of individual profiles from several metaphase spreads. Objective parameters critical for quantitative evaluations were tested, and the criteria for selection of suitable CGH preparations are described. The granularity of the chromosome painting and the regional inhomogeneity of fluorescence intensities in metaphase spreads proved to be crucial parameters. The coefficient of variation of the ratio value for chromosomes in balanced state (CVBS) provides a general quality criterion for CGH experiments. Different cutoff levels (thresholds) of average fluorescence ratio values were compared for their specificity and sensitivity with regard to the detection of chromosomal imbalances. 27 refs., 15 figs., 1 tab.« less

  18. Quantification of Protein Biomarker Using SERS Nano-Stress Sensing with Peak Intensity Ratiometry

    NASA Astrophysics Data System (ADS)

    Goh, Douglas; Kong, Kien Voon; Jayakumar, Perumal; Gong, Tianxun; Dinish, U. S.; Olivo, Malini

    We report a surface enhanced Raman spectroscopy (SERS) ratiometry method based on peak intensity coupled in a nano-stress sensing platform to detect and quantify biological molecules. Herein, we employed an antibody-conjugated p-aminothiophenol (ATP) functionalized on a bimetallic-film-over-nanosphere (BMFON) substrate as a sensitive SERS platform to detect human haptoglobin (Hp) protein, which is an acute phase protein and a biomarker for various cancers. Correlation between change in the ATP spectral characteristics and concentration of Hp protein was established by examining the peak intensity ratio at 1572cm-1 and 1592cm-1 that reflects the degree of stress experienced by the aromatic ring of ATP during Hp protein-antibody interaction. Development of this platform shows the potential in developing a low-cost and sensitive SERS sensor for the pre-screening of various biomarkers.

  19. Dependence of anti-Stokes/Stokes intensity ratios on substrate optical properties for Brillouin light scattering from ultrathin iron films

    NASA Astrophysics Data System (ADS)

    Cochran, J. F.; From, M.; Heinrich, B.

    1998-06-01

    Brillouin light scattering experiments have been used to investigate the intensity of 5145 Å laser light backscattered from spin waves in 20 monolayer thick Fe(001) films. The experiments have shown that the ratio of frequency upshifted light intensity to frequency downshifted light intensity depends upon the material of the substrate used to support the iron films. For a fixed magnetic field and for a fixed angle of incidence of the laser light this intensity ratio is much larger for an iron film deposited on a sulphur passivated GaAs(001) substrate than for an iron film deposited on a Ag(001) substrate. The data have been compared with a calculation that takes into account multiple scattering of the optical waves in the iron film and in a protective gold overlayer. The observations are in qualitative agreement with the theory, except for angles of incidence greater than 60°.

  20. Geometrical optics modeling of the grating-slit test.

    PubMed

    Liang, Chao-Wen; Sasian, Jose

    2007-02-19

    A novel optical testing method termed the grating-slit test is discussed. This test uses a grating and a slit, as in the Ronchi test, but the grating-slit test is different in that the grating is used as the incoherent illuminating object instead of the spatial filter. The slit is located at the plane of the image of a sinusoidal intensity grating. An insightful geometrical-optics model for the grating-slit test is presented and the fringe contrast ratio with respect to the slit width and object-grating period is obtained. The concept of spatial bucket integration is used to obtain the fringe contrast ratio.

  1. Selected isotope ratio measurements of light metallic elements (Li, Mg, Ca, and Cu) by multiple collector ICP-MS

    PubMed Central

    Platzner, Thomas I.; Segal, Irina

    2007-01-01

    The unique capabilities of multiple collector inductively coupled mass spectrometry (MC-ICP-MS) for high precision isotope ratio measurements in light elements as Li, Mg, Ca, and Cu are reviewed in this paper. These elements have been intensively studied at the Geological Survey of Israel (GSI) and other laboratories over the past few years, and the methods used to obtain high precision isotope analyses are discussed in detail. The scientific study of isotopic fractionation of these elements is significant for achieving a better understanding of geochemical and biochemical processes in nature and the environment. PMID:17962922

  2. The application of Gaussian mixture models for signal quantification in MALDI-TOF mass spectrometry of peptides.

    PubMed

    Spainhour, John Christian G; Janech, Michael G; Schwacke, John H; Velez, Juan Carlos Q; Ramakrishnan, Viswanathan

    2014-01-01

    Matrix assisted laser desorption/ionization time-of-flight (MALDI-TOF) coupled with stable isotope standards (SIS) has been used to quantify native peptides. This peptide quantification by MALDI-TOF approach has difficulties quantifying samples containing peptides with ion currents in overlapping spectra. In these overlapping spectra the currents sum together, which modify the peak heights and make normal SIS estimation problematic. An approach using Gaussian mixtures based on known physical constants to model the isotopic cluster of a known compound is proposed here. The characteristics of this approach are examined for single and overlapping compounds. The approach is compared to two commonly used SIS quantification methods for single compound, namely Peak Intensity method and Riemann sum area under the curve (AUC) method. For studying the characteristics of the Gaussian mixture method, Angiotensin II, Angiotensin-2-10, and Angiotenisn-1-9 and their associated SIS peptides were used. The findings suggest, Gaussian mixture method has similar characteristics as the two methods compared for estimating the quantity of isolated isotopic clusters for single compounds. All three methods were tested using MALDI-TOF mass spectra collected for peptides of the renin-angiotensin system. The Gaussian mixture method accurately estimated the native to labeled ratio of several isolated angiotensin peptides (5.2% error in ratio estimation) with similar estimation errors to those calculated using peak intensity and Riemann sum AUC methods (5.9% and 7.7%, respectively). For overlapping angiotensin peptides, (where the other two methods are not applicable) the estimation error of the Gaussian mixture was 6.8%, which is within the acceptable range. In summary, for single compounds the Gaussian mixture method is equivalent or marginally superior compared to the existing methods of peptide quantification and is capable of quantifying overlapping (convolved) peptides within the acceptable margin of error.

  3. Cross-Calibration of Secondary Electron Multiplier in Noble Gas Analysis

    NASA Astrophysics Data System (ADS)

    Santato, Alessandro; Hamilton, Doug; Deerberg, Michael; Wijbrans, Jan; Kuiper, Klaudia; Bouman, Claudia

    2015-04-01

    The latest generation of multi-collector noble gas mass spectrometers has decisively improved the precision in isotopic ratio analysis [1, 2] and helped the scientific community to address new questions [3]. Measuring numerous isotopes simultaneously has two significant advantages: firstly, any fluctuations in signal intensity have no effect on the isotope ratio and secondly, the analysis time is reduced. This particular point becomes very important in static vacuum mass spectrometry where during the analysis, the signal intensity decays and at the same time the background increases. However, when multi-collector analysis is utilized, it is necessary to pay special attention to the cross calibration of the detectors. This is a key point in order to have accurate and reproducible isotopic ratios. In isotope ratio mass spectrometry, with regard to the type of detector (i.e. Faraday or Secondary Electron Multiplier, SEM), analytical technique (TIMS, MC-ICP-MS or IRMS) and isotope system of interest, several techniques are currently applied to cross-calibrate the detectors. Specifically, the gain of the Faraday cups is generally stable and only the associated amplifier must be calibrated. For example, on the Thermo Scientific instrument control systems, the 1011 and 1012 ohm amplifiers can easily be calibrated through a fully software controlled procedure by inputting a constant electric signal to each amplifier sequentially [4]. On the other hand, the yield of the SEMs can drift up to 0.2% / hour and other techniques such as peak hopping, standard-sample bracketing and multi-dynamic measurement must be used. Peak hopping allows the detectors to be calibrated by measuring an ion beam of constant intensity across the detectors whereas standard-sample bracketing corrects the drift of the detectors through the analysis of a reference standard of a known isotopic ratio. If at least one isotopic pair of the sample is known, multi-dynamic measurement can be used; in this case the known isotopic ratio is measured on different pairs of detectors and the true value of the isotopic ratio of interest can be determined by a specific equation. In noble gas analysis, due to the decay of the ion beam during the measurement as well as the special isotopic systematic of the gases themselves, the cross-calibration of the SEM using these techniques becomes more complex and other methods should be investigated. In this work we present a comparison between different approaches to cross-calibrate multiple SEM's in noble gas analysis in order to evaluate the most suitable and reliable method. References: [1] Mark et al. (2009) Geochem. Geophys. Geosyst. 10, 1-9. [2] Mark et al. (2011) Geochim. Cosmochim. 75, 7494-7501. [3] Phillips and Matchan (2013) Geochimica et Cosmochimica Acta 121, 229-239. [4] Koornneef et al. (2014) Journal of Analytical Atomic Spectrometry 28, 749-754.

  4. Evidence of charge exchange pumping in calcium-xenon system

    NASA Technical Reports Server (NTRS)

    Chubb, D. L.

    1973-01-01

    Charge exchange between xenon ions and calcium atoms may produce an inversion between the 5s or 4d and 4p energy levels of the calcium ions. A low power flowing xenon plasma seeded with calcium was utilized to determine if charge exchange or electron collisions populate the 5s and 4d levels Ca(+). Line intensity ratios proportional to the density ratios n5s/n4p and n4d/n4p were measured. From the dependence of these intensity ratios on power input to the xenon plasma it was concluded that charge exchange pumping of the 5s and 4d levels predominates over electron collisional pumping of these levels. Also, by comparing intensity ratios obtained using argon and krypton in place of xenon with those obtained in xenon the same conclusion was made.

  5. Peroxyoxalate chemiluminescence detection of condensates of malondialdehyde with thiobarbituric acids using a flow system.

    PubMed

    Nakashima, K; Nagata, M; Takahashi, M; Akiyama, S

    1992-01-01

    The peroxyoxalate chemiluminescence(CL) detection method for the evaluation of the CL intensity of malondialdehyde(MDA) condensates with seven 2-thiobarbituric acid derivatives is described. The method consists of a flow injection technique together with a CL detection system using bis(2,4,6-trichlorophenyl) oxalate(TCPO) and hydrogen peroxide as chemiluminogenic reagents. Linear correlations between CL intensity and concentration are obtained for pmol levels of condensates. Among the condensates, 1,3-diethyl-2-thiobarbituric acid(DETBA)-MDA shows the largest CL intensity. High performance liquid chromatography (HPLC)/CL detection of DETBA-MDA and 1,3-diphenyl-2-thiobarbituric acid(DPTBA)-MDA using a mixture of TCPO and hydrogen peroxide in acetonitrile as a postcolumn reagent solution is also described. The detection limits for DETBA-MDA and DPTBA-MDA are 20 and 200 fmol, respectively, per 20 microL injection at a signal-to-noise ratio of 2. This HPLC/CL detection system was applied to the determination of MDA in rat brains by using DETBA as a fluorescent derivatizing reagent.

  6. Intense Femtosecond Laser-Mediated Electrical Discharge Enables Preparation of Amorphous Nickel Phosphide Nanoparticles.

    PubMed

    Ma, Zhuo-Chen; Chen, Qi-Dai; Han, Bing; Li, He-Long; Wang, Lei; Zhang, Yong-Lai; Sun, Hong-Bo

    2018-05-09

    Reported here is a high-efficiency preparation method of amorphous nickel phosphide (Ni-P) nanoparticles by intense femtosecond laser irradiation of nickel sulfate and sodium hypophosphite aqueous solution. The underlying mechanism of the laser-assisted preparation was discussed in terms of the breaking of chemical bond in reactants via highly intense electric field discharge generated by the intense femtosecond laser. The morphology and size of the nanoparticles can be tuned by varying the reaction parameters such as ion concentration, ion molar ratio, laser power, and irradiation time. X-ray diffraction and transmission electron microscopy results demonstrated that the nanoparticles were amorphous. Finally, the thermogravimetric-differential thermal analysis experiment verified that the as-synthesized noncrystalline Ni-P nanoparticles had an excellent catalytic capability toward thermal decomposition of ammonium perchlorate. This strategy of laser-mediated electrical discharge under such an extremely intense field may create new opportunities for the decomposition of molecules or chemical bonds that could further facilitate the recombination of new atoms or chemical groups, thus bringing about new possibilities for chemical reaction initiation and nanomaterial synthesis that may not be realized under normal conditions.

  7. SPECTROSOCPIC STUDIES OF IONIZATION IN A HOLLOW-CATHODE DISCHARGE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, K.B.

    1961-08-01

    The influence of carrier gas, carrier gas pressure, cathode geometry, and discharge current on the ionization of metal atoms in a hollow-cathode discharge was studied in some detail. Most of these studies were raade with an iron hollowcathode discharge. A measure of ionization was obtained from the intensity ratio of a line of the second to a line of the first spectrum. In general, this ratio was found to increase with carrier gas pressure and discharge current. This ratio also increased with increasing cathode bcre diameter but decreased with increasing bcre length. This ratio for iron was greatly affected bymore » the use of different inert carrier gases. Of the five common inert gases used, xenon produced the largest value for this ratio and argon produced the smallest. The results of these studies indicated this may be a new method for distinguishing between lines emitted by the neutral atom and lines of the singly ionized atom. (auth)« less

  8. Development of a quantitative diagnostic method of estrogen receptor expression levels by immunohistochemistry using organic fluorescent material-assembled nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonda, Kohsuke, E-mail: gonda@med.tohoku.ac.jp; Miyashita, Minoru; Watanabe, Mika

    2012-09-28

    Highlights: Black-Right-Pointing-Pointer Organic fluorescent material-assembled nanoparticles for IHC were prepared. Black-Right-Pointing-Pointer New nanoparticle fluorescent intensity was 10.2-fold greater than Qdot655. Black-Right-Pointing-Pointer Nanoparticle staining analyzed a wide range of ER expression levels in tissue. Black-Right-Pointing-Pointer Nanoparticle staining enhanced the quantitative sensitivity for ER diagnosis. -- Abstract: The detection of estrogen receptors (ERs) by immunohistochemistry (IHC) using 3,3 Prime -diaminobenzidine (DAB) is slightly weak as a prognostic marker, but it is essential to the application of endocrine therapy, such as antiestrogen tamoxifen-based therapy. IHC using DAB is a poor quantitative method because horseradish peroxidase (HRP) activity depends on reaction time, temperature andmore » substrate concentration. However, IHC using fluorescent material provides an effective method to quantitatively use IHC because the signal intensity is proportional to the intensity of the photon excitation energy. However, the high level of autofluorescence has impeded the development of quantitative IHC using fluorescence. We developed organic fluorescent material (tetramethylrhodamine)-assembled nanoparticles for IHC. Tissue autofluorescence is comparable to the fluorescence intensity of quantum dots, which are the most representative fluorescent nanoparticles. The fluorescent intensity of our novel nanoparticles was 10.2-fold greater than quantum dots, and they did not bind non-specifically to breast cancer tissues due to the polyethylene glycol chain that coated their surfaces. Therefore, the fluorescent intensity of our nanoparticles significantly exceeded autofluorescence, which produced a significantly higher signal-to-noise ratio on IHC-imaged cancer tissues than previous methods. Moreover, immunostaining data from our nanoparticle fluorescent IHC and IHC with DAB were compared in the same region of adjacent tissues sections to quantitatively examine the two methods. The results demonstrated that our nanoparticle staining analyzed a wide range of ER expression levels with higher accuracy and quantitative sensitivity than DAB staining. This enhancement in the diagnostic accuracy and sensitivity for ERs using our immunostaining method will improve the prediction of responses to therapies that target ERs and progesterone receptors that are induced by a downstream ER signal.« less

  9. State-of-the-Art for Assessing Earthquake Hazards in the United States. Report 25. Parameters for Specifying Intensity-Related Earthquake Ground Motions.

    DTIC Science & Technology

    1987-09-01

    and Sponheuer, W. 1969. Scale of Seismic Intensity: Proc. Fourth World Conf. on Earthquake Engineering, Santiago, Chile . Murphy, J. R., and O’Brien, L...Predom V/H el, V/I Vel V/H Displ V/H sec VIH Period Period Predom Accel cm/sec Vel cm Disp .05 Dur sec sec Period S11 2 0.48 MODIFIED MERCALLI INTENSITY...0.1 0. 0.16 142.20 Long. Vert Hor Vert Ratio Ratio Vert Ratio Vert r io Du r atio Predom Predom VIH Acce V/H Vel V /H Dspi V H sec 1, H Period Period

  10. K β to K α X-ray intensity ratios and K to L shell vacancy transfer probabilities of Co, Ni, Cu, and Zn

    NASA Astrophysics Data System (ADS)

    Anand, L. F. M.; Gudennavar, S. B.; Bubbly, S. G.; Kerur, B. R.

    2015-12-01

    The K to L shell total vacancy transfer probabilities of low Z elements Co, Ni, Cu, and Zn are estimated by measuring the K β to K α intensity ratio adopting the 2π-geometry. The target elements were excited by 32.86 keV barium K-shell X-rays from a weak 137Cs γ-ray source. The emitted K-shell X-rays were detected using a low energy HPGe X-ray detector coupled to a 16 k MCA. The measured intensity ratios and the total vacancy transfer probabilities are compared with theoretical results and others' work, establishing a good agreement.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, Nageswara S.; Ramirez Aviles, Camila A.

    We consider the problem of inferring the operational status of a reactor facility using measurements from a radiation sensor network deployed around the facility’s ventilation off-gas stack. The intensity of stack emissions decays with distance, and the sensor counts or measurements are inherently random with parameters determined by the intensity at the sensor’s location. We utilize the measurements to estimate the intensity at the stack, and use it in a one-sided Sequential Probability Ratio Test (SPRT) to infer on/off status of the reactor. We demonstrate the superior performance of this method over conventional majority fusers and individual sensors using (i)more » test measurements from a network of 21 NaI detectors, and (ii) effluence measurements collected at the stack of a reactor facility. We also analytically establish the superior detection performance of the network over individual sensors with fixed and adaptive thresholds by utilizing the Poisson distribution of the counts. We quantify the performance improvements of the network detection over individual sensors using the packing number of the intensity space.« less

  12. Apparatus and method for monitoring the intensities of charged particle beams

    DOEpatents

    Varma, Matesh N.; Baum, John W.

    1982-11-02

    Charged particle beam monitoring means (40) are disposed in the path of a charged particle beam (44) in an experimental device (10). The monitoring means comprise a beam monitoring component (42) which is operable to prevent passage of a portion of beam (44), while concomitantly permitting passage of another portion thereof (46) for incidence in an experimental chamber (18), and providing a signal (I.sub.m) indicative of the intensity of the beam portion which is not passed. Calibration means (36) are disposed in the experimental chamber in the path of the said another beam portion and are operable to provide a signal (I.sub.f) indicative of the intensity thereof. Means (41 and 43) are provided to determine the ratio (R) between said signals whereby, after suitable calibration, the calibration means may be removed from the experimental chamber and the intensity of the said another beam portion determined by monitoring of the monitoring means signal, per se.

  13. Ambiguities in spaceborne synthetic aperture radar systems

    NASA Technical Reports Server (NTRS)

    Li, F. K.; Johnson, W. T. K.

    1983-01-01

    An examination of aspects of spaceborne SAR time delay and Doppler ambiguities has led to the formulation of an accurate method for the evaluation of the ratio of ambiguity intensities to that of the signal, which has been applied to the nominal SAR system on Seasat. After discussing the variation of this ratio as a function of orbital latitude and attitude control error, it is shown that the detailed range migration-azimuth phase history of an ambiguity is different from that of a signal, so that the images of ambiguities are dispersed. Seasat SAR dispersed images are presented, and their dispersions are eliminated through an adjustment of the processing parameters. A method is also presented which uses a set of multiple pulse repetition sequences to determine the Doppler centroid frequency absolute values for SARs with high carrier frequencies and poor attitude measurements.

  14. Determination of Low C Concentration in Czochralski-Grown Si for Solar Cell Applications by Liquid-N-Temperature Photoluminescence After Electron Irradiation

    NASA Astrophysics Data System (ADS)

    Tajima, Michio; Kiuchi, Hirotatsu; Higuchi, Fumito; Ishikawa, Yoichiro; Ogura, Atsushi

    2018-05-01

    The effectiveness of liquid-N-temperature photoluminescence (PL) after electron irradiation for quantification of low-level C has been demonstrated in Czochralski (CZ)-grown Si for solar cell applications. We focused on the intensity ratios of the C- and G-lines to the band-edge emission, which were used as indexes for determining the C concentration in the PL activation method at 4.2 K. Good correlations of the ratio between 4.2 K and 77 K were obtained for samples with similar P and O concentrations after electron irradiation at fluence varying from 1 × 1015 cm-2 to 10 × 1015 cm-2. We applied the present method to quantify the C concentration along the solidified fraction in CZ-Si ingots.

  15. Compaction of rolling circle amplification products increases signal integrity and signal-to-noise ratio

    PubMed Central

    Clausson, Carl-Magnus; Arngården, Linda; Ishaq, Omer; Klaesson, Axel; Kühnemund, Malte; Grannas, Karin; Koos, Björn; Qian, Xiaoyan; Ranefall, Petter; Krzywkowski, Tomasz; Brismar, Hjalmar; Nilsson, Mats; Wählby, Carolina; Söderberg, Ola

    2015-01-01

    Rolling circle amplification (RCA) for generation of distinct fluorescent signals in situ relies upon the self-collapsing properties of single-stranded DNA in commonly used RCA-based methods. By introducing a cross-hybridizing DNA oligonucleotide during rolling circle amplification, we demonstrate that the fluorophore-labeled RCA products (RCPs) become smaller. The reduced size of RCPs increases the local concentration of fluorophores and as a result, the signal intensity increases together with the signal-to-noise ratio. Furthermore, we have found that RCPs sometimes tend to disintegrate and may be recorded as several RCPs, a trait that is prevented with our cross-hybridizing DNA oligonucleotide. These effects generated by compaction of RCPs improve accuracy of visual as well as automated in situ analysis for RCA based methods, such as proximity ligation assays (PLA) and padlock probes. PMID:26202090

  16. Illuminant-adaptive color reproduction for mobile display

    NASA Astrophysics Data System (ADS)

    Kim, Jong-Man; Park, Kee-Hyon; Kwon, Oh-Seol; Cho, Yang-Ho; Ha, Yeong-Ho

    2006-01-01

    This paper proposes an illuminant-adaptive reproduction method using light adaptation and flare conditions for a mobile display. Mobile displays, such as PDAs and cellular phones, are viewed under various lighting conditions. In particular, images displayed in daylight are perceived as quite dark due to the light adaptation of the human visual system, as the luminance of a mobile display is considerably lower than that of an outdoor environment. In addition, flare phenomena decrease the color gamut of a mobile display by increasing the luminance of dark areas and de-saturating the chroma. Therefore, this paper presents an enhancement method composed of lightness enhancement and chroma compensation. First, the ambient light intensity is measured using a lux-sensor, then the flare is calculated based on the reflection ratio of the display device and the ambient light intensity. The relative cone response is nonlinear to the input luminance. This is also changed by the ambient light intensity. Thus, to improve the perceived image, the displayed luminance is enhanced by lightness linearization. In this paper, the image's luminance is transformed by linearization of the response to the input luminance according to the ambient light intensity. Next, the displayed image is compensated according to the physically reduced chroma, resulting from flare phenomena. The reduced chroma value is calculated according to the flare for each intensity. The chroma compensation method to maintain the original image's chroma is applied differently for each hue plane, as the flare affects each hue plane differently. At this time, the enhanced chroma also considers the gamut boundary. Based on experimental observations, the outer luminance-intensity generally ranges from 1,000 lux to 30,000 lux. Thus, in the case of an outdoor environment, i.e. greater than 1,000 lux, this study presents a color reproduction method based on an inverse cone response curve and flare condition. Consequently, the proposed algorithm improves the quality of the perceived image adaptive to an outdoor environment.

  17. Automatic Insall-Salvati ratio measurement on lateral knee x-ray images using model-guided landmark localization

    NASA Astrophysics Data System (ADS)

    Chen, Hsin-Chen; Lin, Chii-Jeng; Wu, Chia-Hsing; Wang, Chien-Kuo; Sun, Yung-Nien

    2010-11-01

    The Insall-Salvati ratio (ISR) is important for detecting two common clinical signs of knee disease: patella alta and patella baja. Furthermore, large inter-operator differences in ISR measurement make an objective measurement system necessary for better clinical evaluation. In this paper, we define three specific bony landmarks for determining the ISR and then propose an x-ray image analysis system to localize these landmarks and measure the ISR. Due to inherent artifacts in x-ray images, such as unevenly distributed intensities, which make landmark localization difficult, we hence propose a registration-assisted active-shape model (RAASM) to localize these landmarks. We first construct a statistical model from a set of training images based on x-ray image intensity and patella shape. Since a knee x-ray image contains specific anatomical structures, we then design an algorithm, based on edge tracing, for patella feature extraction in order to automatically align the model to the patella image. We can estimate the landmark locations as well as the ISR after registration-assisted model fitting. Our proposed method successfully overcomes drawbacks caused by x-ray image artifacts. Experimental results show great agreement between the ISRs measured by the proposed method and by orthopedic clinicians.

  18. Differential quantitative proteomics of Porphyromonas gingivalis by linear ion trap mass spectrometry: non-label methods comparison, q-values and LOWESS curve fitting

    PubMed Central

    Xia, Qiangwei; Wang, Tiansong; Park, Yoonsuk; Lamont, Richard J.; Hackett, Murray

    2009-01-01

    Differential analysis of whole cell proteomes by mass spectrometry has largely been applied using various forms of stable isotope labeling. While metabolic stable isotope labeling has been the method of choice, it is often not possible to apply such an approach. Four different label free ways of calculating expression ratios in a classic “two-state” experiment are compared: signal intensity at the peptide level, signal intensity at the protein level, spectral counting at the peptide level, and spectral counting at the protein level. The quantitative data were mined from a dataset of 1245 qualitatively identified proteins, about 56% of the protein encoding open reading frames from Porphyromonas gingivalis, a Gram-negative intracellular pathogen being studied under extracellular and intracellular conditions. Two different control populations were compared against P. gingivalis internalized within a model human target cell line. The q-value statistic, a measure of false discovery rate previously applied to transcription microarrays, was applied to proteomics data. For spectral counting, the most logically consistent estimate of random error came from applying the locally weighted scatter plot smoothing procedure (LOWESS) to the most extreme ratios generated from a control technical replicate, thus setting upper and lower bounds for the region of experimentally observed random error. PMID:19337574

  19. Redshifted and blueshifted photoluminescence emission of InAs/InP quantum dots upon amorphization of phase change material.

    PubMed

    Humam, Nurrul Syafawati Binti; Sato, Yu; Takahashi, Motoki; Kanazawa, Shohei; Tsumori, Nobuhiro; Regreny, Philippe; Gendry, Michel; Saiki, Toshiharu

    2014-06-16

    We present the mechanisms underlying the redshifted and blueshifted photoluminescence (PL) of quantum dots (QDs) upon amorphization of phase change material (PCM). We calculated the stress and energy shift distribution induced by volume expansion using finite element method. Simulation result reveals that redshift is obtained beneath the flat part of amorphous mark, while blueshift is obtained beneath the edge region of amorphous mark. Simulation result is accompanied by two experimental studies; two-dimensional PL intensity mapping of InAs/InP QD sample deposited by a layer of PCM, and an analysis on the relationship between PL intensity ratio and energy shift were performed.

  20. Multiscale hidden Markov models for photon-limited imaging

    NASA Astrophysics Data System (ADS)

    Nowak, Robert D.

    1999-06-01

    Photon-limited image analysis is often hindered by low signal-to-noise ratios. A novel Bayesian multiscale modeling and analysis method is developed in this paper to assist in these challenging situations. In addition to providing a very natural and useful framework for modeling an d processing images, Bayesian multiscale analysis is often much less computationally demanding compared to classical Markov random field models. This paper focuses on a probabilistic graph model called the multiscale hidden Markov model (MHMM), which captures the key inter-scale dependencies present in natural image intensities. The MHMM framework presented here is specifically designed for photon-limited imagin applications involving Poisson statistics, and applications to image intensity analysis are examined.

  1. A hybrid patient-specific biomechanical model based image registration method for the motion estimation of lungs.

    PubMed

    Han, Lianghao; Dong, Hua; McClelland, Jamie R; Han, Liangxiu; Hawkes, David J; Barratt, Dean C

    2017-07-01

    This paper presents a new hybrid biomechanical model-based non-rigid image registration method for lung motion estimation. In the proposed method, a patient-specific biomechanical modelling process captures major physically realistic deformations with explicit physical modelling of sliding motion, whilst a subsequent non-rigid image registration process compensates for small residuals. The proposed algorithm was evaluated with 10 4D CT datasets of lung cancer patients. The target registration error (TRE), defined as the Euclidean distance of landmark pairs, was significantly lower with the proposed method (TRE = 1.37 mm) than with biomechanical modelling (TRE = 3.81 mm) and intensity-based image registration without specific considerations for sliding motion (TRE = 4.57 mm). The proposed method achieved a comparable accuracy as several recently developed intensity-based registration algorithms with sliding handling on the same datasets. A detailed comparison on the distributions of TREs with three non-rigid intensity-based algorithms showed that the proposed method performed especially well on estimating the displacement field of lung surface regions (mean TRE = 1.33 mm, maximum TRE = 5.3 mm). The effects of biomechanical model parameters (such as Poisson's ratio, friction and tissue heterogeneity) on displacement estimation were investigated. The potential of the algorithm in optimising biomechanical models of lungs through analysing the pattern of displacement compensation from the image registration process has also been demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. High dynamic range fringe acquisition: A novel 3-D scanning technique for high-reflective surfaces

    NASA Astrophysics Data System (ADS)

    Jiang, Hongzhi; Zhao, Huijie; Li, Xudong

    2012-10-01

    This paper presents a novel 3-D scanning technique for high-reflective surfaces based on phase-shifting fringe projection method. High dynamic range fringe acquisition (HDRFA) technique is developed to process the fringe images reflected from the shiny surfaces, and generates a synthetic fringe image by fusing the raw fringe patterns, acquired with different camera exposure time and the illumination fringe intensity from the projector. Fringe image fusion algorithm is introduced to avoid saturation and under-illumination phenomenon by choosing the pixels in the raw fringes with the highest fringe modulation intensity. A method of auto-selection of HDRFA parameters is developed and largely increases the measurement automation. The synthetic fringes have higher signal-to-noise ratio (SNR) under ambient light by optimizing HDRFA parameters. Experimental results show that the proposed technique can successfully measure objects with high-reflective surfaces and is insensitive to ambient light.

  3. Causal Structure of Brain Physiology after Brain Injury from Subarachnoid Hemorrhage.

    PubMed

    Claassen, Jan; Rahman, Shah Atiqur; Huang, Yuxiao; Frey, Hans-Peter; Schmidt, J Michael; Albers, David; Falo, Cristina Maria; Park, Soojin; Agarwal, Sachin; Connolly, E Sander; Kleinberg, Samantha

    2016-01-01

    High frequency physiologic data are routinely generated for intensive care patients. While massive amounts of data make it difficult for clinicians to extract meaningful signals, these data could provide insight into the state of critically ill patients and guide interventions. We develop uniquely customized computational methods to uncover the causal structure within systemic and brain physiologic measures recorded in a neurological intensive care unit after subarachnoid hemorrhage. While the data have many missing values, poor signal-to-noise ratio, and are composed from a heterogeneous patient population, our advanced imputation and causal inference techniques enable physiologic models to be learned for individuals. Our analyses confirm that complex physiologic relationships including demand and supply of oxygen underlie brain oxygen measurements and that mechanisms for brain swelling early after injury may differ from those that develop in a delayed fashion. These inference methods will enable wider use of ICU data to understand patient physiology.

  4. Comparison of Inner Ear Contrast Enhancement among Patients with Unilateral Inner Ear Symptoms in MR Images Obtained 10 Minutes and 4 Hours after Gadolinium Injection.

    PubMed

    Kim, T Y; Park, D W; Lee, Y J; Lee, J Y; Lee, S H; Chung, J H; Lee, S

    2015-12-01

    Recently 4-hour delayed-enhanced 3D-FLAIR MR imaging has been used in pathophysiologic analysis of the inner ear in many auditory diseases, including sudden sensorineural hearing loss, but comparison among different time points is not clear in patients with unilateral inner ear symptoms. We compared the signal-intensity ratios of the inner ears in patients with unilateral inner ear symptoms on 10-minute delayed-enhanced and 4-hour delayed-enhanced 3D-FLAIR MR images after IV gadolinium injection. The 10-minute delayed-enhanced and 4-hour delayed-enhanced 3D-FLAIR MR images were retrospectively analyzed. Signal-intensity ratios between the cerebellum and inner ear structures, such as the cochleae, vestibules, and vestibulocochlear nerve were assessed. Multiple comparisons were performed. Signal-intensity ratios of the affected cochleae, vestibules, and vestibulocochlear nerve were higher than those of unaffected sides in both 10-minute delayed-enhanced and 4-hour delayed-enhanced images. At the affected side, signal-intensity ratios of the vestibulocochlear nerve were higher in patients with nonsudden sensorineural hearing loss than in those with sudden sensorineural hearing loss on both 10-minute delayed-enhanced and 4-hour delayed-enhanced images. The signal-intensity ratios of some affected inner ear structures were higher than those of the unaffected sides in a group of 30 patients with sudden sensorineural hearing loss and 20 patients with nonsudden sensorineural hearing loss on 10-minute delayed-enhanced and 4-hour delayed-enhanced images. Signal-intensity ratios of the inner ear show statistically significant increases in many diseases, especially neuritis, in 10-minute delayed-enhanced and 4-hour delayed-enhanced images. The 4-hour delayed-enhanced images may be superior in neural inflammatory-dominant conditions, while 10-minute delayed-enhanced images may be superior in neural noninflammatory-dominant conditions. © 2015 by American Journal of Neuroradiology.

  5. Quantitative ROESY analysis of computational models: structural studies of citalopram and β-cyclodextrin complexes by (1) H-NMR and computational methods.

    PubMed

    Ali, Syed Mashhood; Shamim, Shazia

    2015-07-01

    Complexation of racemic citalopram with β-cyclodextrin (β-CD) in aqueous medium was investigated to determine atom-accurate structure of the inclusion complexes. (1) H-NMR chemical shift change data of β-CD cavity protons in the presence of citalopram confirmed the formation of 1 : 1 inclusion complexes. ROESY spectrum confirmed the presence of aromatic ring in the β-CD cavity but whether one of the two or both rings was not clear. Molecular mechanics and molecular dynamic calculations showed the entry of fluoro-ring from wider side of β-CD cavity as the most favored mode of inclusion. Minimum energy computational models were analyzed for their accuracy in atomic coordinates by comparison of calculated and experimental intermolecular ROESY peak intensities, which were not found in agreement. Several least energy computational models were refined and analyzed till calculated and experimental intensities were compatible. The results demonstrate that computational models of CD complexes need to be analyzed for atom-accuracy and quantitative ROESY analysis is a promising method. Moreover, the study also validates that the quantitative use of ROESY is feasible even with longer mixing times if peak intensity ratios instead of absolute intensities are used. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Quantitative analysis for the determination of aluminum percentage and detonation performance of aluminized plastic bonded explosives by laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Rezaei, A. H.; Keshavarz, M. H.; Kavosh Tehrani, M.; Darbani, S. M. R.

    2018-06-01

    The aluminized plastic-bonded explosive (PBX) is a composite material in which solid explosive particles are dispersed in a polymer matrix, which includes three major components, i.e. polymeric binder, metal fuel (aluminum) and nitramine explosive. This work introduces a new method on the basis of the laser-induced breakdown spectroscopy (LIBS) technique in air and argon atmospheres to investigate the determination of aluminum content and detonation performance of aluminized PBXs. Plasma emissions of aluminized PBXs are recorded where atomic lines of Al, C and H as well as molecular bands of AlO and CN are identified. The experimental results demonstrate that a good discrimination and separation between the aluminized PBXs is possible using LIBS and principle component analysis, although they have similar atomic composition. Relative intensity of the AlO/Al is used to determine aluminum percentage of the aluminized PBXs. The obtained quantitative calibration curve using the relative intensity of the AlO/Al is better than the resulting calibration curve using only the intensity of Al. By using the LIBS method and the measured intensity ratio of CN/C, an Al content of 15% is found to be the optimum value in terms of velocity of detonation of the RDX/Al/HTPB standard samples.

  7. Theoretical study of depth profiling with gamma- and X-ray spectrometry based on measurements of intensity ratios

    NASA Astrophysics Data System (ADS)

    Bártová, H.; Trojek, T.; Johnová, K.

    2017-11-01

    This article describes the method for the estimation of depth distribution of radionuclides in a material with gamma-ray spectrometry, and the identification of a layered structure of a material with X-ray fluorescence analysis. This method is based on the measurement of a ratio of two gamma or X-ray lines of a radionuclide or a chemical element, respectively. Its principle consists in different attenuation coefficient for these two lines in a measured material. The main aim of this investigation was to show how the detected ratio of these two lines depends on depth distribution of an analyte and mainly how this ratio depends on density and chemical composition of measured materials. Several different calculation arrangements were made and a lot of Monte Carlo simulation with the code MCNP - Monte Carlo N-Particle (Briesmeister, 2000) was performed to answer these questions. For X-ray spectrometry, the calculated Kα/Kβ diagrams were found to be almost independent upon matrix density and composition. Thanks to this phenomenon it would be possible to draw only one Kα/Kβ diagram for an element whose depth distribution is examined.

  8. Factors associated with success in the oral part of the European Diploma in Intensive Care.

    PubMed

    Waldauf, Petr; Rubulotta, Francesca; Sitzwohl, Christian; Elbers, Paul; Girbes, Armand; Saha, Rajnish; Marsh, Brian; Kumar, Ravindra; Maggiorini, Marco; Duška, František

    2017-11-01

    The oral part of European Diploma in Intensive Care diploma examinations changed in 2013 into an objective structured clinical examination-type exam. This step was undertaken to provide a fair and reproducible clinical exam. All candidates face identical questions with predefined correct answers simultaneously in seven high throughput exam centres on the same day. We describe the factors that are associated with success in part 2 European Diploma in Intensive Care exam. We prospectively collected self-reported data from all candidates sitting European Diploma in Intensive Care part 2 in 2015, namely demographics, professional background and attendance to a European Diploma in Intensive Care part 2 or generic objective structured clinical examination preparatory courses. After testing association with success (with cutoff at p < 0.10) and co-linearity of these factors as independent variables, we performed a multivariate logistical analysis, with binary exam outcome (pass/fail) as the dependent variable. Structural equation modelling was used to gain further insight into relations among determinants of success in the oral part of the European Diploma in Intensive Care. Out of 427 candidates sitting the exam, completed data from 341 (80%) were available for analysis. The following candidates' factors were associated with increased chance of success: English as native language (odds ratio 4.3 (95% CI 1.7-10.7)), use of Patient-centred Acute Care Training e-learning programme module (odds ratios 2.0 (1.2-3.3)), working in an EU country (odds ratios 2.5 (1.5-4.3)), and better results in the written part of the European Diploma in Intensive Care (for each additional SD of 6.1 points odds ratios 1.9 (1.4-2.4)). Chance of success in the European Diploma in Intensive Care 2 decreased with increased candidates 'age (for each additional SD of 5.5 years odds ratios 0.67 (0.51-0.87)). Exam centres (7 in total) could be clustered into 3 groups with similar success rates. There were significant differences in exam outcomes among these 3 groups of exam centres even after adjustment to known candidates' factors (G1 vs G2 odds ratios 2.4 (1.4-4.1); G1 vs G3 odds ratios 9.7 (4.0-23.1) and G2 vs G3 odds ratios 3.9 (1.7-9.2)). A short data collection period (only one year) and 20% of missing candidates' data are the main limitations of this study. Younger age, English as native language, better results in written part of the exam, working at a European country and the use of PACT for preparation, were factors associated with success in the oral part of the European Diploma in Intensive Care exam. Despite the limitations of this study, the differences in outcome among the exam centres will need further investigation.

  9. (1 + 1) resonant enhanced multiphoton ionization via the A2Sigma(+) state of NO - Ionic rotational branching ratios and their intensity dependence

    NASA Technical Reports Server (NTRS)

    Rudolph, H.; Mckoy, V.; Dixit, S. N.; Huo, W. M.

    1988-01-01

    Rotational branching ratios resulting from the (1 + 1) resonant enhanced multiphoton ionization spectroscopy of NO via the 0-0 transition of the A-X band for the four possible branches that can be assigned as R(21.5) are explored using calculation performed in the frozen-core approximation at the Hartree-Fock level. The four different branches, of which three are distinctly different in the perturbative limit, have rather different branching ratios. The mixed R12 + Q22(21.5) branch, which is not intense and has the lowest transition energy, appears to give the best agreement with experimental branching ratio for parallel detection. The agreement is less satisfactory for perpendicular detection. Neither the effect of finite-acceptance angle of the photoelectron detector nor high intensities can explain the discrepancy.

  10. Efficacy of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for the quantitative evaluation of the structural integrity of superficial digital flexor tendons in horses.

    PubMed

    van Schie, H T; Bakker, E M; Jonker, A M; van Weeren, P R

    2001-07-01

    To evaluate effectiveness of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for quantitative evaluation of tendon structural integrity in horses. 4 superficial digital flexor tendons (2 damaged tendons, 2 normal tendons). Transverse ultrasonographic images that precisely matched histologic sections were obtained in fixed steps along the long axis of each tendon. Distribution, intensity, and delineation of structure-related echoes, quantitatively expressed as the correlation ratio and steadiness ratio , were compared with histologic findings in tissue that was normal or had necrosis, early granulation, late granulation, early fibrosis, or inferior repair. In normal tendon, the even distribution of structure-related echoes with high intensity and sharp delineation yielded high correlation ratio and steadiness ratio. In areas of necrosis, collapsed endotendon septa yielded solid but blurred structure-related echoes (high correlation ration and low steadiness ratio). In early granulation tissue, complete lack of organization caused zero values for both ratios. In late granulation tissue, reorganization and swollen endotendon septa yielded poorly delineated structure-related echoes (high correlation ratio, low steadiness ratio). In early fibrosis, rearrangement of bundles resulted in normal correlation ration and slightly low steadiness ratio. In inferior repair, the almost complete lack of structural reorganization resulted in heterogeneous poorly delineated low-intensity echoes (low correlation ratio and steadiness ratio). The combination of correlation ratio and steadiness ratio accurately reflects histopathologic findings, making computerized correlation of ultrasonographic images an efficient tool for quantitative evaluation of tendon structural integrity.

  11. Image Processing for Bioluminescence Resonance Energy Transfer Measurement-BRET-Analyzer.

    PubMed

    Chastagnier, Yan; Moutin, Enora; Hemonnot, Anne-Laure; Perroy, Julie

    2017-01-01

    A growing number of tools now allow live recordings of various signaling pathways and protein-protein interaction dynamics in time and space by ratiometric measurements, such as Bioluminescence Resonance Energy Transfer (BRET) Imaging. Accurate and reproducible analysis of ratiometric measurements has thus become mandatory to interpret quantitative imaging. In order to fulfill this necessity, we have developed an open source toolset for Fiji- BRET-Analyzer -allowing a systematic analysis, from image processing to ratio quantification. We share this open source solution and a step-by-step tutorial at https://github.com/ychastagnier/BRET-Analyzer. This toolset proposes (1) image background subtraction, (2) image alignment over time, (3) a composite thresholding method of the image used as the denominator of the ratio to refine the precise limits of the sample, (4) pixel by pixel division of the images and efficient distribution of the ratio intensity on a pseudocolor scale, and (5) quantification of the ratio mean intensity and standard variation among pixels in chosen areas. In addition to systematize the analysis process, we show that the BRET-Analyzer allows proper reconstitution and quantification of the ratiometric image in time and space, even from heterogeneous subcellular volumes. Indeed, analyzing twice the same images, we demonstrate that compared to standard analysis BRET-Analyzer precisely define the luminescent specimen limits, enlightening proficient strengths from small and big ensembles over time. For example, we followed and quantified, in live, scaffold proteins interaction dynamics in neuronal sub-cellular compartments including dendritic spines, for half an hour. In conclusion, BRET-Analyzer provides a complete, versatile and efficient toolset for automated reproducible and meaningful image ratio analysis.

  12. Stress Ratio Effects on Small Fatigue Crack Growth in Ti-6Al-4V (Preprint)

    DTIC Science & Technology

    2008-11-01

    crack effect is observed in this alloy , consistent with previous observations, where small cracks grew at stress intensity factor ranges below the long...high stress intensity factor ranges, ΔK, on the order of 10 MPa√m or greater. A significant small crack effect is observed in this alloy , consistent...the behavior of small cracks under different stress ratios in Ti-6Al-4V, an alloy commonly used for fan airfoils. The effect of stress ratio on

  13. Reproducible MRI Measurement of Adipose Tissue Volumes in Genetic and Dietary Rodent Obesity Models

    PubMed Central

    Johnson, David H.; Flask, Chris A.; Ernsberger, Paul R.; Wong, Wilbur C. K.; Wilson, David L.

    2010-01-01

    Purpose To develop ratio MRI [lipid/(lipid+water)] methods for assessing lipid depots and compare measurement variability to biological differences in lean controls (spontaneously hypertensive rats, SHRs), dietary obese (SHR-DO), and genetic/dietary obese (SHROBs) animals. Materials and Methods Images with and without CHESS water-suppression were processed using a semi-automatic method accounting for relaxometry, chemical shift, receive coil sensitivity, and partial volume. Results Partial volume correction improved results by 10–15%. Over six operators, volume variation was reduced to 1.9 ml from 30.6 ml for single-image-analysis with intensity inhomogeneity. For three acquisitions on the same animal, volume reproducibility was <1%. SHROBs had 6X visceral and 8X subcutaneous adipose tissue than SHRs. SHR-DOs had enlarged visceral depots (3X SHRs). SHROB had significantly more subcutaneous adipose tissue, indicating a strong genetic component to this fat depot. Liver ratios in SHR-DO and SHROB were higher than SHR, indicating elevated fat content. Among SHROBs, evidence suggested a phenotype SHROB* having elevated liver ratios and visceral adipose tissue volumes. Conclusion Effects of diet and genetics on obesity were significantly larger than variations due to image acquisition and analysis, indicating that these methods can be used to assess accumulation/depletion of lipid depots in animal models of obesity. PMID:18821617

  14. Laser-induced plasma characterization through self-absorption quantification

    NASA Astrophysics Data System (ADS)

    Hou, JiaJia; Zhang, Lei; Zhao, Yang; Yan, Xingyu; Ma, Weiguang; Dong, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang

    2018-07-01

    A self-absorption quantification method is proposed to quantify the self-absorption degree of spectral lines, in which plasma characteristics including electron temperature, elemental concentration ratio, and absolute species number density can be deduced directly. Since there is no spectral intensity involved in the calculation, the analysis results are independent of the self-absorption effects and the additional spectral efficiency calibration is not required. In order to evaluate the practicality, the limitation for application and the precision of this method are also discussed. Experimental results of aluminum-lithium alloy prove that the proposed method is qualified to realize semi-quantitative measurements and fast plasma characteristics diagnostics.

  15. Elastostatic stress analysis of orthotropic rectangular center-cracked plates

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, G. S.; Mendelson, A.

    1972-01-01

    A mapping-collocation method was developed for the elastostatic stress analysis of finite, anisotropic plates with centrally located traction-free cracks. The method essentially consists of mapping the crack into the unit circle and satisfying the crack boundary conditions exactly with the help of Muskhelishvili's function extension concept. The conditions on the outer boundary are satisfied approximately by applying the method of least-squares boundary collocation. A parametric study of finite-plate stress intensity factors, employing this mapping-collocation method, is presented. It shows the effects of varying material properties, orientation angle, and crack-length-to-plate-width and plate-height-to-plate-width ratios for rectangular orthotropic plates under constant tensile and shear loads.

  16. Robust phase retrieval of complex-valued object in phase modulation by hybrid Wirtinger flow method

    NASA Astrophysics Data System (ADS)

    Wei, Zhun; Chen, Wen; Yin, Tiantian; Chen, Xudong

    2017-09-01

    This paper presents a robust iterative algorithm, known as hybrid Wirtinger flow (HWF), for phase retrieval (PR) of complex objects from noisy diffraction intensities. Numerical simulations indicate that the HWF method consistently outperforms conventional PR methods in terms of both accuracy and convergence rate in multiple phase modulations. The proposed algorithm is also more robust to low oversampling ratios, loose constraints, and noisy environments. Furthermore, compared with traditional Wirtinger flow, sample complexity is largely reduced. It is expected that the proposed HWF method will find applications in the rapidly growing coherent diffractive imaging field for high-quality image reconstruction with multiple modulations, as well as other disciplines where PR is needed.

  17. Cigarette Smoking and Pancreatic Cancer: A Pooled Analysis From the Pancreatic Cancer Cohort Consortium

    PubMed Central

    Vrieling, Alina; Lubin, Jay H.; Kraft, Peter; Mendelsohn, Julie B.; Hartge, Patricia; Canzian, Federico; Steplowski, Emily; Arslan, Alan A.; Gross, Myron; Helzlsouer, Kathy; Jacobs, Eric J.; LaCroix, Andrea; Petersen, Gloria; Zheng, Wei; Albanes, Demetrius; Amundadottir, Laufey; Bingham, Sheila A.; Boffetta, Paolo; Boutron-Ruault, Marie-Christine; Chanock, Stephen J.; Clipp, Sandra; Hoover, Robert N.; Jacobs, Kevin; Johnson, Karen C.; Kooperberg, Charles; Luo, Juhua; Messina, Catherine; Palli, Domenico; Patel, Alpa V.; Riboli, Elio; Shu, Xiao-Ou; Rodriguez Suarez, Laudina; Thomas, Gilles; Tjønneland, Anne; Tobias, Geoffrey S.; Tong, Elissa; Trichopoulos, Dimitrios; Virtamo, Jarmo; Ye, Weimin; Yu, Kai; Zeleniuch-Jacquette, Anne; Bueno-de-Mesquita, H. Bas; Stolzenberg-Solomon, Rachael Z.

    2009-01-01

    Smoking is an established risk factor for pancreatic cancer; however, detailed examination of the association of smoking intensity, smoking duration, and cumulative smoking dose with pancreatic cancer is limited. The authors analyzed pooled data from the international Pancreatic Cancer Cohort Consortium nested case-control study (1,481 cases, 1,539 controls). Odds ratios and 95% confidence intervals were calculated by using unconditional logistic regression. Smoking intensity effects were examined with an excess odds ratio model that was linear in pack-years and exponential in cigarettes smoked per day and its square. When compared with never smokers, current smokers had a significantly elevated risk (odds ratio (OR) = 1.77, 95% confidence interval (CI): 1.38, 2.26). Risk increased significantly with greater intensity (≥30 cigarettes/day: OR = 1.75, 95% CI: 1.27, 2.42), duration (≥50 years: OR = 2.13, 95% CI: 1.25, 3.62), and cumulative smoking dose (≥40 pack-years: OR = 1.78, 95% CI: 1.35, 2.34). Risk more than 15 years after smoking cessation was similar to that for never smokers. Estimates of excess odds ratio per pack-year declined with increasing intensity, suggesting greater risk for total exposure delivered at lower intensity for longer duration than for higher intensity for shorter duration. This finding and the decline in risk after smoking cessation suggest that smoking has a late-stage effect on pancreatic carcinogenesis. PMID:19561064

  18. Optimum parameters of image preprocessing method for Shack-Hartmann wavefront sensor in different SNR condition

    NASA Astrophysics Data System (ADS)

    Wei, Ping; Li, Xinyang; Luo, Xi; Li, Jianfeng

    2018-02-01

    The centroid method is commonly adopted to locate the spot in the sub-apertures in the Shack-Hartmann wavefront sensor (SH-WFS), in which preprocessing image is required before calculating the spot location due to that the centroid method is extremely sensitive to noises. In this paper, the SH-WFS image was simulated according to the characteristics of the noises, background and intensity distribution. The Optimal parameters of SH-WFS image preprocessing method were put forward, in different signal-to-noise ratio (SNR) conditions, where the wavefront reconstruction error was considered as the evaluation index. Two methods of image preprocessing, thresholding method and windowing combing with thresholding method, were compared by studying the applicable range of SNR and analyzing the stability of the two methods, respectively.

  19. Fluorescent pH sensor based on Ag@SiO2 core-shell nanoparticle.

    PubMed

    Bai, Zhenhua; Chen, Rui; Si, Peng; Huang, Youju; Sun, Handong; Kim, Dong-Hwan

    2013-06-26

    We have demonstrated a novel method for the preparation of a fluorescence-based pH sensor by combining the plasmon resonance band of Ag core and pH sensitive dye (HPTS). A thickness-variable silica shell is placed between Ag core and HPTS dye to achieve the maximum fluorescence enhancement. At the shell thickness of 8 nm, the fluorescence intensity increases 4 and 9 times when the sensor is excited at 405 and 455 nm, respectively. At the same time, the fluorescence intensity shows a good sensitivity toward pH value in the range of 5-9, and the ratio of emission intensity at 513 nm excited at 455 nm to that excited at 405 nm versus the pH value in the range of 5-9 is determined. It is believed that the present pH sensor has the potential for determining pH real time in the biological sample.

  20. Aqueous synthesis of L-cysteine and mercaptopropionic acid co-capped ZnS quantum dots with dual emissions

    NASA Astrophysics Data System (ADS)

    Ren, Yingkun; Wang, Yongbo; Yang, Min; Liu, Enzhou; Hu, Xiaoyun; Zhang, Xu; Fan, Jun

    2018-07-01

    In this paper, L-cysteine (L-cys) and mercaptopropionic acid (MPA) co-capped ZnS quantum dots (QDs) with dual emissions have been successfully synthesized by a one-pot aqueous-phase synthesis method. The intensities of the dual emissions could be controlled by regulating the molar ratio of L-cys to MPA, and the fluorescence color also turned from blue to yellow accordingly. The relationship between the ligands and fluorescence was investigated and the results indicated that L-cys could cause two emissions and MPA improved the emission intensity. In addition, the L-cys-MPA co-capped ZnS QDs showed high photostability under UV irradiation. Therefore, the L-cys-MPA co-capped ZnS QDs, which show the dual emissions and tunable emission intensities, have great potentials for use in ratiometric fluorescence sensors and multicolor bioimaging.

  1. Energy intensity of computer manufacturing: hybrid assessment combining process and economic input-output methods.

    PubMed

    Williams, Eric

    2004-11-15

    The total energy and fossil fuels used in producing a desktop computer with 17-in. CRT monitor are estimated at 6400 megajoules (MJ) and 260 kg, respectively. This indicates that computer manufacturing is energy intensive: the ratio of fossil fuel use to product weight is 11, an order of magnitude larger than the factor of 1-2 for many other manufactured goods. This high energy intensity of manufacturing, combined with rapid turnover in computers, results in an annual life cycle energy burden that is surprisingly high: about 2600 MJ per year, 1.3 times that of a refrigerator. In contrast with many home appliances, life cycle energy use of a computer is dominated by production (81%) as opposed to operation (19%). Extension of usable lifespan (e.g. by reselling or upgrading) is thus a promising approach to mitigating energy impacts as well as other environmental burdens associated with manufacturing and disposal.

  2. Upconversion luminescence from Er-N codoped of ZnO nanowires prepared by ion implantation method

    NASA Astrophysics Data System (ADS)

    Zhong, Kun; Xu, Jie; Su, Jing; Chen, Yu lin

    2011-02-01

    Nitrogen and erbium co-doped of ZnO nanowires (NWs) are fabricated by ion implantation and subsequent annealing in air. The incorporation of Er3+ and N+ ions is verified by energy dispersive X-ray spectroscopy (EDS) and Raman spectra. The samples exhibit upconversion photoluminescence around ∼550 nm and ∼660 nm under an excitation at 980 nm. It is discovered that the N-doped can drastically increase the upconversion photoluminescence intensity by modifying the local structure around Er3+ in ZnO matrix. The enhancement of the PL intensity by the N-doped is caused by the formation of ErO6-xNx octahedron complexes. With the increase of the annealing temperature (Ta), the Er3+ ions diffuse towards the surface of the NWs, which benefits the red emission and evokes the variation of intensity ratio owing to the existence of some organic groups.

  3. Physical Training Status Determines Oxidative Stress and Redox Changes in Response to an Acute Aerobic Exercise

    PubMed Central

    Damirchi, Arsalan; Farjaminezhad, Manoochehr

    2016-01-01

    Objective. To assess the influence of different physical training status on exercise-induced oxidative stress and changes in cellular redox state. Methods. Thirty male subjects participated in this study and were assigned as well-trained (WT), moderately trained (MT), and untrained (UT) groups. The levels of cortisol, creatine kinase, plasma reduced glutathione to oxidized glutathione (GSH/GSSG), cysteine/cystine (Cys/CySS), and GSH/GSSG ratio in red blood cells (RBCs) were measured immediately and 10 and 30 min after exercise. Results. Following the exercise, plasma GSH/GSSG (p = 0.001) and Cys/CySS (p = 0.005) were significantly reduced in all groups. Reduction in plasma GSH/GSSG ratio in all groups induced a transient shift in redox balance towards a more oxidizing environment without difference between groups (p = 0.860), while RBCs GSH/GSSG showed significant reduction (p = 0.003) and elevation (p = 0.007) in UT and MT groups, respectively. The highest level of RBCs GSH/GSSG ratio was recorded in MT group, and the lowest one was recorded in the WT group. Conclusion. Long term regular exercise training with moderate intensity shifts redox balance towards more reducing environment, versus intensive exercise training leads to more oxidizing environment and consequently development of related diseases. PMID:27064342

  4. Quantification of the Robusta fraction in a coffee blend via Raman spectroscopy: proof of principle.

    PubMed

    Wermelinger, Thomas; D'Ambrosio, Lucio; Klopprogge, Babette; Yeretzian, Chahan

    2011-09-14

    Among the 100 different known Coffea species, Coffea arabica L. (Arabica) and Coffea canephora Pierre (Robusta) are the only two of commercial interest. They differ in a range of agronomic, genetic, and chemical properties. Due to the significant price difference between Arabica and Robusta, there is an economic incentive to illicitly replace Arabica with Robusta. Therefore, it is crucial to have accurate methods to determine the Robusta-to-Arabica-ratio in blends. This paper presents the proof of principle of a new and fast approach to determine the Robusta fraction in a blend based on Raman spectroscopy. The oils of two references (a pure Robusta and pure Arabica coffee) and six blends thereof consisting of different Robusta and Arabica fractions were extracted using a Soxhlet system. The solutes were analyzed by means of Raman spectroscopy without further workup. Using the intensity ratio between two Raman peaks, one characteristic for kahweol and one characteristic for fatty acids, allowed determinination of the Robusta content in a given mixture. The intensity ratio is linearly dependent on the Robusta content of the compound. Above a Robusta content of 75 wt %, kahweol was not detectable. The Raman data are in agreement with results obtained from the very time-consuming multistep DIN 10777 procedures based on HPLC.

  5. K{sub β} to K{sub α} X-ray intensity ratios and K to L shell vacancy transfer probabilities of Co, Ni, Cu, and Zn

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anand, L. F. M.; Gudennavar, S. B., E-mail: shivappa.b.gudennavar@christuniversity.in; Bubbly, S. G.

    The K to L shell total vacancy transfer probabilities of low Z elements Co, Ni, Cu, and Zn are estimated by measuring the K{sub β} to K{sub α} intensity ratio adopting the 2π-geometry. The target elements were excited by 32.86 keV barium K-shell X-rays from a weak {sup 137}Cs γ-ray source. The emitted K-shell X-rays were detected using a low energy HPGe X-ray detector coupled to a 16 k MCA. The measured intensity ratios and the total vacancy transfer probabilities are compared with theoretical results and others’ work, establishing a good agreement.

  6. Long-term effects of intensive glucose lowering on cardiovascular outcomes.

    PubMed

    Gerstein, Hertzel C; Miller, Michael E; Genuth, Saul; Ismail-Beigi, Faramarz; Buse, John B; Goff, David C; Probstfield, Jeffrey L; Cushman, William C; Ginsberg, Henry N; Bigger, J Thomas; Grimm, Richard H; Byington, Robert P; Rosenberg, Yves D; Friedewald, William T

    2011-03-03

    Intensive glucose lowering has previously been shown to increase mortality among persons with advanced type 2 diabetes and a high risk of cardiovascular disease. This report describes the 5-year outcomes of a mean of 3.7 years of intensive glucose lowering on mortality and key cardiovascular events. We randomly assigned participants with type 2 diabetes and cardiovascular disease or additional cardiovascular risk factors to receive intensive therapy (targeting a glycated hemoglobin level below 6.0%) or standard therapy (targeting a level of 7 to 7.9%). After termination of the intensive therapy, due to higher mortality in the intensive-therapy group, the target glycated hemoglobin level was 7 to 7.9% for all participants, who were followed until the planned end of the trial. Before the intensive therapy was terminated, the intensive-therapy group did not differ significantly from the standard-therapy group in the rate of the primary outcome (a composite of nonfatal myocardial infarction, nonfatal stroke, or death from cardiovascular causes) (P=0.13) but had more deaths from any cause (primarily cardiovascular) (hazard ratio, 1.21; 95% confidence interval [CI], 1.02 to 1.44) and fewer nonfatal myocardial infarctions (hazard ratio, 0.79; 95% CI, 0.66 to 0.95). These trends persisted during the entire follow-up period (hazard ratio for death, 1.19; 95% CI, 1.03 to 1.38; and hazard ratio for nonfatal myocardial infarction, 0.82; 95% CI, 0.70 to 0.96). After the intensive intervention was terminated, the median glycated hemoglobin level in the intensive-therapy group rose from 6.4% to 7.2%, and the use of glucose-lowering medications and rates of severe hypoglycemia and other adverse events were similar in the two groups. As compared with standard therapy, the use of intensive therapy for 3.7 years to target a glycated hemoglobin level below 6% reduced 5-year nonfatal myocardial infarctions but increased 5-year mortality. Such a strategy cannot be recommended for high-risk patients with advanced type 2 diabetes. (Funded by the National Heart, Lung and Blood Institute; ClinicalTrials.gov number, NCT00000620.).

  7. Water Mapping Using Multispectral Airborne LIDAR Data

    NASA Astrophysics Data System (ADS)

    Yan, W. Y.; Shaker, A.; LaRocque, P. E.

    2018-04-01

    This study investigates the use of the world's first multispectral airborne LiDAR sensor, Optech Titan, manufactured by Teledyne Optech to serve the purpose of automatic land-water classification with a particular focus on near shore region and river environment. Although there exist recent studies utilizing airborne LiDAR data for shoreline detection and water surface mapping, the majority of them only perform experimental testing on clipped data subset or rely on data fusion with aerial/satellite image. In addition, most of the existing approaches require manual intervention or existing tidal/datum data for sample collection of training data. To tackle the drawbacks of previous approaches, we propose and develop an automatic data processing workflow for land-water classification using multispectral airborne LiDAR data. Depending on the nature of the study scene, two methods are proposed for automatic training data selection. The first method utilizes the elevation/intensity histogram fitted with Gaussian mixture model (GMM) to preliminarily split the land and water bodies. The second method mainly relies on the use of a newly developed scan line elevation intensity ratio (SLIER) to estimate the water surface data points. Regardless of the training methods being used, feature spaces can be constructed using the multispectral LiDAR intensity, elevation and other features derived from these parameters. The comprehensive workflow was tested with two datasets collected for different near shore region and river environment, where the overall accuracy yielded better than 96 %.

  8. Effects of light quality on leaf morphogenesis of a heterophyllous amphibious plant, Rotala hippuris

    PubMed Central

    Momokawa, Naoko; Kadono, Yasuro; Kudoh, Hiroshi

    2011-01-01

    Background and Aims For heterophyllous amphibious plants that experience fluctuating water levels, it is critical to control leaf development precisely in response to environmental cues that can serve as a quantitative index of water depth. Light quality can serve as such a cue because the ratio of red light relative to far-red light (R/FR) increases and blue-light intensity decreases with increasing water depth. Growth experiments were conducted to examine how R/FR and blue-light intensity alter leaf morphology of a heterophyllous amphibious plant, Rotala hippuris. Methods Using combinations of far red (730 nm), red (660 nm) and blue (470 nm) light-emitting diodes (LEDs), growth experiments were used to quantitatively evaluate the effects of the R/FR ratio and blue-light intensity on leaf morphology. Key Results Under the natural light regime in an outside growth garden, R. hippuris produced distinct leaves under submerged and aerial conditions. R/FR and blue-light intensity were found to markedly affect heterophyllous leaf formation. Higher and lower R/FR caused leaf characters more typical of submerged and aerial leaves, respectively, in both aerial and submerged conditions, in accordance with natural distribution of leaf types and light under water. High blue light caused a shift of trait values toward those of typical aerial leaves, and the response was most prominent under conditions of R/FR that were expected near the water surface. Conclusions R/FR and blue-light intensity provides quantitative cues for R. hippuris to detect water depth and determine the developmental fates of leaves, especially near the water surface. The utilization of these quantitative cues is expected to be important in habitats where plants experience water-level fluctuation. PMID:21896573

  9. The Affective Dimension of Laboratory Dyspnea

    PubMed Central

    Banzett, Robert B.; Pedersen, Sarah H.; Schwartzstein, Richard M.; Lansing, Robert W.

    2008-01-01

    Rationale: It is hypothesized that the affective dimension of dyspnea (unpleasantness, emotional response) is not strictly dependent on the intensity of dyspnea. Objectives: We tested the hypothesis that the ratio of immediate unpleasantness (A1) to sensory intensity (SI) varies depending on the type of dyspnea. Methods: Twelve healthy subjects experienced three stimuli: stimulus 1: maximal eucapnic voluntary hyperpnea against inspiratory resistance, requiring 15 times the work of resting breathing; stimulus 2: PetCO2 6.1 mm Hg above resting with ventilation restricted to less than spontaneous breathing; stimulus 3: PetCO2 7.7 mm Hg above resting with ventilation further restricted. After each trial, subjects rated SI, A1, and qualities of dyspnea on the Multidimensional Dyspnea Profile (MDP), a comprehensive instrument tested here for the first time. Measurements and Main Results: Stimulus 1 was always limited by subjects failing to meet a higher ventilation target; none signaled severe discomfort. This evoked work and effort sensations, with relatively low unpleasantness (mean A1/SI = 0.64). Stimulus 2, titrated to produce dyspnea ratings similar to those subjects gave during stimulus 1, evoked air hunger and produced significantly greater unpleasantness (mean A1/SI = 0.95). Stimulus 3, increased until air hunger was intolerable, evoked the highest intensity and unpleasantness ratings and high unpleasantness ratio (mean A1/SI = 1.09). When asked which they would prefer to repeat, all subjects chose stimulus 1. Conclusions: (1) Maximal respiratory work is less unpleasant than moderately intense air hunger in this brief test; (2) unpleasantness of dyspnea can vary independently from perceived intensity, consistent with the prevailing model of pain; (3) separate dimensions of dyspnea can be measured with the MDP. PMID:18369200

  10. Racial and Ethnic Service Use Disparities Among Homeless Adults With Severe Mental Illnesses Receiving ACT

    PubMed Central

    Horvitz-Lennon, Marcela; Zhou, Dongli; Normand, Sharon-Lise T.; Alegría, Margarita; Thompson, Wes K.

    2013-01-01

    Objective Case management–based interventions aimed at improving quality of care have the potential to narrow racial and ethnic disparities among people with chronic illnesses. The aim of this study was to assess the equity effects of assertive community treatment (ACT), an evidence-based case management intervention, among homeless adults with severe mental illness. Methods This study used baseline, three-, and 12-month data for 6,829 black, Latino, and white adults who received ACT services through the ACCESS study (Access to Community Care and Effective Services and Support). Zero-inflated Poisson random regression models were used to estimate the adjusted probability of use of outpatient psychiatric services and, among service users, the intensity of use. Odds ratios and rate ratios (RRs) were computed to assess disparities at baseline and over time. Results No disparities were found in probability of use at baseline or over time. Compared with white users, baseline intensity of use was lower for black users (RR=.89; 95% confidence interval [CI]=.83–.96) and Latino users (RR=.65; CI=.52–.81]). Intensity did not change over time for whites, but it did for black and Latino users. Intensity increased for blacks between baseline and three months (RR=1.11, CI=1.06–1.17]) and baseline and 12 months (RR=1.17, CI=1.11–1.22]). Intensity of use dropped for Latinos between baseline and three months (RR=.83, CI=.70–.98). Conclusions Receipt of ACT was associated with a reduction in service use disparities for blacks but not for Latinos. Findings suggest that ACT’s equity effects differ depending on race-ethnicity. PMID:21632726

  11. Effects of (monomer - crosslinker – initiator) composition during non imprinted polymers synthesis for catechin retention

    NASA Astrophysics Data System (ADS)

    Triadhi, U.; Zulfikar, M. A.; Setiyanto, H.; Amran, M. B.

    2018-05-01

    MISPE (molecularly imprinted Solid Phase Extraction) is a separation technique using a solid adsorbent as a principle of MI (molecularly imprinted). Methacrylic acid (MAA) was used as a monomer, ethylene glycol dimethacrylate (EGDMA) as a crosslinker, benzoyl peroxide (BPO) as an initiator and acetonitrile (ACN) as a porogen. Catechin will be used as the template. Thermal and microwave methods were employed in the synthesis method. When analyzed using FTIR spectra, it was found that there were no significant differences between NIP (non-imprinted polymer) resulting from thermal method and that resulting from microwave method. Preparation of polymers by microwave method required 4 mins at 60-65 °C, significantly less than thermal method, that took 60 minutes at the same temperature. The variations of mole ratios of the monomer, the crosslinker, and the initiator were also performed. Based on the FTIR spectra, intensity of some peaks were changed due to the decreases of concentration. The optimum composition for NIP synthesis was MAA: EGDMA: BPO ratio of 5:30:0.5 (in mmole). The TGA curve showed that the NIP sythesized using microwave method experienced mass loss of around 98.50% at 604.8 °C.

  12. A pilot study on quantification of training load: The use of HRV in training practice.

    PubMed

    Saboul, Damien; Balducci, Pascal; Millet, Grégoire; Pialoux, Vincent; Hautier, Christophe

    2016-01-01

    Recent laboratory studies have suggested that heart rate variability (HRV) may be an appropriate criterion for training load (TL) quantification. The aim of this study was to validate a novel HRV index that may be used to assess TL in field conditions. Eleven well-trained long-distance male runners performed four exercises of different duration and intensity. TL was evaluated using Foster and Banister methods. In addition, HRV measurements were performed 5 minutes before exercise and 5 and 30 minutes after exercise. We calculated HRV index (TLHRV) based on the ratio between HRV decrease during exercise and HRV increase during recovery. HRV decrease during exercise was strongly correlated with exercise intensity (R = -0.70; p < 0.01) but not with exercise duration or training volume. TLHRV index was correlated with Foster (R = 0.61; p = 0.01) and Banister (R = 0.57; p = 0.01) methods. This study confirms that HRV changes during exercise and recovery phase are affected by both intensity and physiological impact of the exercise. Since the TLHRV formula takes into account the disturbance and the return to homeostatic balance induced by exercise, this new method provides an objective and rational TL index. However, some simplification of the protocol measurement could be envisaged for field use.

  13. Cerebral perfusion imaging with bolus harmonic imaging (Honorable Mention Poster Award)

    NASA Astrophysics Data System (ADS)

    Kier, Christian; Toth, Daniel; Meyer-Wiethe, Karsten; Schindler, Angela; Cangur, Hakan; Seidel, Gunter; Aach, Til

    2005-04-01

    Fast visualisation of cerebral microcirculation supports diagnosis of acute stroke. However, the commonly used CT/MRI-based methods are time consuming, costly and not applicable to every patient. The bolus perfusion harmonic imaging (BHI) method is an ultrasound imaging technique which makes use of the fact, that ultrasound contrast agents unlike biological tissues resonate at harmonic frequencies. Exploiting this effect, the contrast between perfused and non-perfused areas can be improved. Thus, BHI overcomes the low signal-to-noise ratio of transcranial ultrasound and the high impedance of the skull. By analysing image sequences, visualising the qualitative characteristics of an US contrast agent bolus injection becomes possible. The analysis consists of calculating four perfusion-related parameters, Local Peak Intensity, Time To Peak, Area Under Curve, and Average Rising, from the time/intensity curve and providing them as colour-coded images. For calculating these parameters the fundamental assumption is that image intensity corresponds to contrast agent concentration which in turn shows the perfusion of the corresponding brain region. In a clinical study on patients suffering from acute ischemic stroke it is shown that some of the parameters correlate significantly to the infarction area. Thus, BHI becomes a less time-consuming and inexpensive bedside method for diagnosis of cerebral perfusion deficits.

  14. [Fire behavior of ground surface fuels in Pinus koraiensis and Quercus mongolica mixed forest under no wind and zero slope condition: a prediction with extended Rothermel model].

    PubMed

    Zhang, Ji-Li; Liu, Bo-Fei; Chu, Teng-Fei; Di, Xue-Ying; Jin, Sen

    2012-06-01

    A laboratory burning experiment was conducted to measure the fire spread speed, residual time, reaction intensity, fireline intensity, and flame length of the ground surface fuels collected from a Korean pine (Pinus koraiensis) and Mongolian oak (Quercus mongolica) mixed stand in Maoer Mountains of Northeast China under the conditions of no wind, zero slope, and different moisture content, load, and mixture ratio of the fuels. The results measured were compared with those predicted by the extended Rothermel model to test the performance of the model, especially for the effects of two different weighting methods on the fire behavior modeling of the mixed fuels. With the prediction of the model, the mean absolute errors of the fire spread speed and reaction intensity of the fuels were 0.04 m X min(-1) and 77 kW X m(-2), their mean relative errors were 16% and 22%, while the mean absolute errors of residual time, fireline intensity and flame length were 15.5 s, 17.3 kW X m(-1), and 9.7 cm, and their mean relative errors were 55.5%, 48.7%, and 24%, respectively, indicating that the predicted values of residual time, fireline intensity, and flame length were lower than the observed ones. These errors could be regarded as the lower limits for the application of the extended Rothermel model in predicting the fire behavior of similar fuel types, and provide valuable information for using the model to predict the fire behavior under the similar field conditions. As a whole, the two different weighting methods did not show significant difference in predicting the fire behavior of the mixed fuels by extended Rothermel model. When the proportion of Korean pine fuels was lower, the predicted values of spread speed and reaction intensity obtained by surface area weighting method and those of fireline intensity and flame length obtained by load weighting method were higher; when the proportion of Korean pine needles was higher, the contrary results were obtained.

  15. Effect of light on N2 fixation and net nitrogen release of Trichodesmium in a field study

    NASA Astrophysics Data System (ADS)

    Lu, Yangyang; Wen, Zuozhu; Shi, Dalin; Chen, Mingming; Zhang, Yao; Bonnet, Sophie; Li, Yuhang; Tian, Jiwei; Kao, Shuh-Ji

    2018-01-01

    Dinitrogen fixation (NF) by marine cyanobacteria is an important pathway to replenish the oceanic bioavailable nitrogen inventory. Light is the key to modulating NF; however, field studies investigating the light response curve (NF-I curve) of NF rate and the effect of light on diazotroph-derived nitrogen (DDN) net release are relatively sparse in the literature, hampering prediction using models. A dissolution method was applied using uncontaminated 15N2 gas to examine how the light changes may influence the NF intensity and DDN net release in the oligotrophic ocean. Experiments were conducted at stations with diazotrophs dominated by filamentous cyanobacterium Trichodesmium spp. in the western Pacific and the South China Sea. The effect of light on carbon fixation (CF) was measured in parallel using the 13C tracer method specifically for a station characterized by Trichodesmium bloom. Both NF-I and CF-I curves showed a Ik (light saturation coefficient) range of 193 to 315 µE m-2 s-1, with light saturation at around 400 µE m-2 s-1. The proportion of DDN net release ranged from ˜ 6 to ˜ 50 %, suggesting an increasing trend as the light intensity decreased. At the Trichodesmium bloom station, we found that the CF / NF ratio was light-dependent and the ratio started to increase as light was lower than the carbon compensation point of 200 µE m-2 s-1. Under low-light stress, Trichodesmium physiologically preferred to allocate more energy for CF to alleviate the intensive carbon consumption by respiration; thus, there is a metabolism tradeoff between CF and NF pathways. Results showed that short-term ( < 24 h) light change modulates the physiological state, which subsequently determined the C / N metabolism and DDN net release by Trichodesmium. Reallocation of energy associated with the variation in light intensity would be helpful for prediction of the global biogeochemical cycle of N by models involving Trichodesmium blooms.

  16. Neutron Capture Reaction on 112Cd to Study of the s-process Origin of 115Sn

    NASA Astrophysics Data System (ADS)

    Hayakawa, Takehito; Toh, Yosuke; Shizuma, Toshiyuki; Kimura, Atsushi; Nakamura, Shoji; Harada, Hideo; Iwamoto, Nobuyuki; Kajino, Toshitaka; Chiba, Satoshi

    The astrophysical origin of 115Sn has remained still an open question. An isomer with a half-life of 14.1 y in 113Cd is a branching point from which a nucleosynthesis flow reaches to a rare isotope 115Sn. The s-process abundance of 115Sn depends on the ratio of the 112Cd(n, γ)113Cdm reaction cross section to the 112Cd(n, γ)113Cdgs reaction cross section. However, the isomer production ratio following the neutron capture reaction has not been measured in an energy region higher than the thermal energy. We have measured γ-ray intensity ratios following neutron capture reactions on 112Cd using the HPGe detectors in conjunction with a time-of-flight method at ANNRI in J-PARC.

  17. ESR signals in quartz for the studies of earth surface processes

    NASA Astrophysics Data System (ADS)

    Toyoda, S.; Shimada, A., , Dr; Takada, M.

    2017-12-01

    Various ESR (electron spin resonance) signals are observed in quartz. As they are formed by natural radiation, the signals are useful in dating of geological events, such as volcanic eruption, faulting and sedimentation. It was also found that those paramagnetic defects can be fingerprints of sediments, to be used for studies in sediment provenance. The signal of the E1' center, unpaired electron at an oxygen vacancy, was first used for such studies. A method was proposed to estimate the number of the precursors (oxygen vacancies) from the E1' center intensity. The number of oxygen vacancies in quartz was found to have positive correlation with the crystallization age. Using this feature, studies were quite successful in aeolian dust. It was shown that the sources of aeolian dust deposited in northern part of Japanese Islands were different between in MIS1 and MIS 2. In combination with crystallinity index, the contributions of the dust components from three origins were quantitatively obtained. After these, the provenance studies on river sediments have started where the impurity centers in quartz were employed, which are the Al center, the Ti centers, and the Ge centers. Sediments of Kizu River, Mie to Nara prefectures in Central Japan are most extensively studied. Firstly, it was shown that each of possible sources of granitic quartz around the reaches has respective characteristics in the number of oxygen vacancies and the signal intensities of impurity centers. Secondary, by the artificial mixing experiments, the impurity signal intensities have the values consistent with the mixing ratio of the two samples of quartz with different intensities. At river junctions, the mixing ratios were calculated from the ESR signals. At some locations, the mixing ratio values obtained from one signal were consistent with the ones from another signal while at some locations they were not. The latter inconsistent results would indicate that the river sediments are inhomogeneous and complicated. Several results will be presented showing the source to sink changes in the ESR signal intensities along with the river. The signals are basically consistent with the possible sources in the river beds having the variation due to the inflow of the tributaries.

  18. Physiological and Technical-tactical Analysis in Brazilian Jiu-jitsu Competition

    PubMed Central

    Andreato, Leonardo V.; Franchini, Emerson; de Moraes, Solange M.F.; Pastório, Juliana J.; da Silva, Danilo F.; Esteves, João V.D.C; Branco, Braulio H.M.; Romero, Paulo V.dS.; Machado, Fabiana A.

    2013-01-01

    Purpose The present study aims at investigating the physiological response and technical-tactical parameters in Brazilian jiu-jitsu competition. Methods The study included 35 male Brazilian jiu-jitsu athletes (adult category, body mass: 80.2 ± 13.0 kg), graded from white to brown belt, during combats fought at regional level. Twenty-two fights were analyzed in terms of technique and time structure. Blood glucose, lactate and maximal isometric grip strength were determined before and after the fights. The rate of perceived exertion was also assessed after the fight, using the 6-20 Borg rating. The fights were recorded and the following variables were determined: the exertion/pause ratio and subjective intensity of actions, categorized between low and high intensity. Results The results indicated that during Brazilian jiu-jitsu fights, the glycolytic pathway is only moderately activated (lactate before: 4.4 (4.0 – 4.6) mmol/L, after: 10.1 (8.0 – 11.3) mmol/L; glucose before: 112.4 ± 22.3 mg/dL, after: 130.5 ± 31.0 mg/dL). The exertion during the fight resulted in significant reductions in handgrip strength (right hand grip before: 45.9 ± 10.3 kgf, after: 40.1 ± 9.5 kgf; left hand grip before: 44.2 ± 11.1 kgf, after: 37.0 ± 10.2 kgf). The athletes rated the fight as hard: 15 (13 – 15). Effort/pause ratio was 6:1, while high-intensity actions lasted approximately 4 s, resulting in a low/high intensity? ratio of 8:1. Conclusion It is recommended that coaches direct the training loads to simulate the energy demand imposed by the competitive matches, activating moderately the glycolytic pathway. Moreover, the time structure of combats can be used to prescribe both physical and technical-tactical training. PMID:23802056

  19. New valid spectrofluorimetric method for determination of selected cephalosporins in different pharmaceutical formulations using safranin as fluorophore.

    PubMed

    Derayea, Sayed M; Ahmed, Hytham M; Abdelmageed, Osama H; Haredy, Ahmed M

    2016-01-15

    A new validated spectrofluorimetric method has been developed for the determination of some cephalosporins namely; cefepime, cefaclor, cefadroxil, cefpodoxime and cefexime. The method was based on the reaction of these drugs with safranin in slightly alkaline medium (pH 8.0), to form ion-association complexes. The fluorescent products were extracted into chloroform and their fluorescence intensities were measured at 544-565 nm after excitation at 518-524 nm. The reaction conditions influencing the product formation and stability were investigated and optimized. The relative fluorescence intensity was proportional to the drug concentration in the linear ranges of 0.15-1.35, 0.35-1.25, 0.35-1.25, 0.20-1.44 and 0.20-1.25 μg/mL for cefepime, cefaclor, cefadroxil, cefpodoxime proxetil and cefexime, respectively. The detection limits were 40, 100, 100, 60 and 70 ng/mL, respectively. The performance of the developed method was evaluated in terms of Student's t-test and variance ratio F-test to find out the significance of proposed methods over the reference spectrophotometric method. Various pharmaceutical formulations were successfully analyzed using the proposed method and the results were in good agreement with those of the previously reported methods. Copyright © 2015. Published by Elsevier B.V.

  20. New valid spectrofluorimetric method for determination of selected cephalosporins in different pharmaceutical formulations using safranin as fluorophore

    NASA Astrophysics Data System (ADS)

    Derayea, Sayed M.; Ahmed, Hytham M.; Abdelmageed, Osama H.; Haredy, Ahmed M.

    2016-01-01

    A new validated spectrofluorimetric method has been developed for the determination of some cephalosporins namely; cefepime, cefaclor, cefadroxil, cefpodoxime and cefexime. The method was based on the reaction of these drugs with safranin in slightly alkaline medium (pH 8.0), to form ion-association complexes. The fluorescent products were extracted into chloroform and their fluorescence intensities were measured at 544-565 nm after excitation at 518-524 nm. The reaction conditions influencing the product formation and stability were investigated and optimized. The relative fluorescence intensity was proportional to the drug concentration in the linear ranges of 0.15-1.35, 0.35-1.25, 0.35-1.25, 0.20-1.44 and 0.20-1.25 μg/mL for cefepime, cefaclor, cefadroxil, cefpodoxime proxetil and cefexime, respectively. The detection limits were 40, 100, 100, 60 and 70 ng/mL, respectively. The performance of the developed method was evaluated in terms of Student's t-test and variance ratio F-test to find out the significance of proposed methods over the reference spectrophotometric method. Various pharmaceutical formulations were successfully analyzed using the proposed method and the results were in good agreement with those of the previously reported methods.

  1. A prediction method for broadband shock associated noise from supersonic rectangualr jets

    NASA Technical Reports Server (NTRS)

    Tam, Christopher K. W.; Reddy, N. N.

    1993-01-01

    Braodband shock associated noise is an important aircraft noise component of the proposed high-speed civil transport (HSCT) at take-offs and landings. For noise certification purpose one would, therefore, like to be able to predict as accurately as possible the intensity, directivity and spectral content of this noise component. The purpose of this work is to develop a semi-empirical prediction method for the broadband shock associated noise from supersonic rectangular jets. The complexity and quality of the noise prediction method are to be similar to those for circular jets. In this paper only the broadband shock associated noise of jets issued from rectangular nozzles with straight side walls is considered. Since many current aircraft propulsion systems have nozzle aspect ratios (at nozzle exit) in the range of 1 to 4, the present study has been confined to nozzles with aspect ratio less than 6. In developing the prediction method the essential physics of the problem are taken into consideration. Since the braodband shock associated noise generation mechanism is the same whether the jet is circular or round the present prediction method in a number of ways is quite similar to that for axisymmetric jets. Comparisons between predictions and measurements for jets with aspect ratio up to 6 will be reported. Efforts will be concentrated on the fly-over plane. However, side line angles and other directions will also be included.

  2. Deconvolution imaging of weak reflective pipe defects using guided-wave signals captured by a scanning receiver.

    PubMed

    Sun, Zeqing; Sun, Anyu; Ju, Bing-Feng

    2017-02-01

    Guided-wave echoes from weak reflective pipe defects are usually interfered by coherent noise and difficult to interpret. In this paper, a deconvolution imaging method is proposed to reconstruct defect images from synthetically focused guided-wave signals, with enhanced axial resolution. A compact transducer, circumferentially scanning around the pipe, is used to receive guided-wave echoes from discontinuities at a distance. This method achieves a higher circumferential sampling density than arrayed transducers-up to 72 sampling spots per lap for a pipe with a diameter of 180 mm. A noise suppression technique is used to enhance the signal-to-noise ratio. The enhancement in both signal-to-noise ratio and axial resolution of the method is experimentally validated by the detection of two kinds of artificial defects: a pitting defect of 5 mm in diameter and 0.9 mm in maximum depth, and iron pieces attached to the pipe surface. A reconstructed image of the pitting defect is obtained with a 5.87 dB signal-to-noise ratio. It is revealed that a high circumferential sampling density is important for the enhancement of the inspection sensitivity, by comparing the images reconstructed with different down-sampling ratios. A modified full width at half maximum is used as the criterion to evaluate the circumferential extent of the region where iron pieces are attached, which is applicable for defects with inhomogeneous reflection intensity.

  3. Advanced characterization of electrowetting retroreflectors.

    PubMed

    Kilaru, Murali K; Yang, Jia; Heikenfeld, Jason

    2009-09-28

    Electrowetting retroreflectors use a simple and scalable construction, and incorporate an electrically tunable liquid lenslet. By electrically modulating the lenslet geometry, the reflection is switched between retroreflection and scattering. In this paper, we report new capability and characterization, including higher index liquids and contrast ratio as a function of contact angle (theta(V)). The reflected intensity is also spatially profiled and reported as a function of view angle. A high contrast ratio of >16X is demonstrated, and methods for further improving performance are discussed. Because the electrowetting retroreflector platform is broad spectrum (VIS-IR), the electrowetting retroreflector may be useful for a large variety of naked eye applications such as safety markings, road-signage, or friend-foe-identification.

  4. Excitation of atomic nitrogen by electron impact

    NASA Technical Reports Server (NTRS)

    Stone, E. J.; Zipf, E. C.

    1972-01-01

    Absolute cross sections were measured for the excitation of the N I(1134, 1164, 1168, 1200, 1243, and 1743 A) multiplets by electron impact on atomic nitrogen. The presence of vibrationally excited molecular nitrogen in the discharged gas was confirmed, and its effect on the measurements is discussed. The ratio of the oscillator strengths of the 1200 and 1134 A resonance transitions is presented, as well as the branching ratio for the N I(1311/1164 A) multiplets. Striking differences in the distribution of intensity between the spectra of atomic nitrogen and molecular nitrogen excited by energetic electrons suggest an optical method for measuring the density of atomic nitrogen in the upper atmosphere.

  5. Measurements of Electron Impact Excitation Cross Sections at the Harvard-Smithsonian Center for Astrophysics

    NASA Technical Reports Server (NTRS)

    Gardner, L. D.; Kohl, J. L.

    2006-01-01

    The analysis of absolute spectral line intensities and intensity ratios with spectroscopic diagnostic techniques provides empirical determinations of chemical abundances, electron densities and temperatures in astrophysical objects. Since spectral line intensities and their ratios are controlled by the excitation rate coefficients for the electron temperature of the observed astrophysical structure, it is imperative that one have accurate values for the relevant rate coefficients. Here at the Harvard-Smithsonian Center for Astrophysics, we have been carrying out measurements of electron impact excitation (EIE) for more than 25 years.

  6. Automatic segmentation of solitary pulmonary nodules based on local intensity structure analysis and 3D neighborhood features in 3D chest CT images

    NASA Astrophysics Data System (ADS)

    Chen, Bin; Kitasaka, Takayuki; Honma, Hirotoshi; Takabatake, Hirotsugu; Mori, Masaki; Natori, Hiroshi; Mori, Kensaku

    2012-03-01

    This paper presents a solitary pulmonary nodule (SPN) segmentation method based on local intensity structure analysis and neighborhood feature analysis in chest CT images. Automated segmentation of SPNs is desirable for a chest computer-aided detection/diagnosis (CAS) system since a SPN may indicate early stage of lung cancer. Due to the similar intensities of SPNs and other chest structures such as blood vessels, many false positives (FPs) are generated by nodule detection methods. To reduce such FPs, we introduce two features that analyze the relation between each segmented nodule candidate and it neighborhood region. The proposed method utilizes a blob-like structure enhancement (BSE) filter based on Hessian analysis to augment the blob-like structures as initial nodule candidates. Then a fine segmentation is performed to segment much more accurate region of each nodule candidate. FP reduction is mainly addressed by investigating two neighborhood features based on volume ratio and eigenvector of Hessian that are calculates from the neighborhood region of each nodule candidate. We evaluated the proposed method by using 40 chest CT images, include 20 standard-dose CT images that we randomly chosen from a local database and 20 low-dose CT images that were randomly chosen from a public database: LIDC. The experimental results revealed that the average TP rate of proposed method was 93.6% with 12.3 FPs/case.

  7. Photon scattering in the solar ultraviolet lines of HeI and HeII

    NASA Astrophysics Data System (ADS)

    Jordan, C.; Smith, G. R.; Houdebine, E. R.

    2005-09-01

    Observations made with the Coronal Diagnostic Spectrometer (CDS) onboard the Solar and Heliospheric Observatory (SOHO) are used to investigate the behaviour of the intensities of the emission lines of HeI, HeII and OIII at the quiet Sun-centre and at θ= 60° towards the equatorial limb. The aim is to examine the possible effects of photon scattering on the spatial variation of the optically thick helium lines. At the quiet Sun-centre, we find that, in agreement with previous work, the ratios of the intensities of the HeI 584-Åand HeII 304-Ålines to those of the OIII 600-Åline decrease systematically as the intensity of the OIII line increases. However, we find that the dependence of these ratios on the OIII intensity is not unique, but differs between the individual regions studied. Similar results are found at θ= 60°. We have also used line intensities and intensity ratios to investigate limb-to-disc effects and variations across a sample of supergranulation cell boundaries and adjacent cell interiors at both locations. The results do not exclude photon scattering as the cause of the larger observed ratios in cell interiors. The differences between the apparent widths of boundaries in OIII at Sun-centre and 60° show that the emitting material is extended in height, which will aid the process of scattering into cell interiors. Photon scattering could also account for the lack of oscillations in the HeI intensities in a cell interior studied by Pietarila & Judge. Three-dimensional radiative transfer calculations in chosen geometries are now needed to account for the observations in detail.

  8. Mechanism of Film Cooling with One Inlet and Double Outlet Hole Injection at Various Turbulence Intensities

    NASA Astrophysics Data System (ADS)

    Li, Guangchao; Chen, Yukai; Kou, Zhihai; Zhang, Wei; Zhang, Guochen

    2018-03-01

    The trunk-branch hole was designed as a novel film cooling concept, which aims for improving film cooling performance by producing anti-vortex. The trunk-branch hole is easily manufactured in comparison with the expanded hole since it consists of two cylindrical holes. The effect of turbulence on the film cooling effectiveness with a trunk-branch hole injection was investigated at the blowing ratios of 0.5, 1.0, 1.5 and 2.0 by numerical simulation. The turbulence intensities from 0.4 % to 20 % were considered. The realizable k-ɛ k - ɛ turbulence model and the enhanced wall function were used. The more effective anti-vortex occurs at the low blowing ratio of 0.5 %. The high turbulence intensity causes the effectiveness evenly distributed in the spanwise direction. The increase of turbulence intensity leads to a slight decrease of the spanwise averaged effectiveness at the low blowing ratio of 0.5, but a significant increase at the high blowing ratios of 1.5 and 2.0. The optimal blowing ratio of the averaged surface effectiveness is improved from 1.0 to 1.5 when the turbulence intensity increases from 0.4 % to 20 %.

  9. Optimized endoscopic autofluorescence spectroscopy for the identification of premalignant lesions in Barrett's oesophagus.

    PubMed

    Holz, Jasmin A; Boerwinkel, David F; Meijer, Sybren L; Visser, Mike; van Leeuwen, Ton G; Aalders, Maurice C G; Bergman, Jacques J G H M

    2013-12-01

    Fluorescence spectroscopy has the potential to detect early cellular changes in Barrett's oesophagus before these become visible. As the technique is based on varying concentrations of intrinsic fluorophores, each with its own optimal excitation wavelength, it is important to assess the optimal excitation wavelength(s) for identification of premalignant lesions in patients with Barrett's oesophagus. The endoscopic spectroscopy system used contained five (ultra)violet light sources (λexc=369-416 nm) to generate autofluorescence during routine endoscopic surveillance. Autofluorescence spectroscopy was followed by a biopsy for histological assessment and spectra correlation. Three intensity ratios (r1, r2, r3) were calculated by dividing the area, A, under the spectral curve of selected emission wavelength ranges for each spectrum generated by each excitation wavelength λexc as follows (Equation is included in full-text article.). Double intensity ratios were calculated using two excitation wavelengths. Fifty-eight tissue areas from 22 patients were used for autofluorescence spectra analysis. Excitation with 395, 405 or 410 nm showed a significant (P≤0.0006) differentiation between intestinal metaplasia and grouped high-grade dysplasia/early carcinoma for intensity ratios r2 and r3. A sensitivity of 80.0% and specificity of 89.5% with an area under the ROC curve of 0.85 was achieved using 395 nm excitation and intensity ratio r3. Double excitation showed no additional value over single excitation. The combination of 395 nm excitation and intensity ratio r3 showed optimal conditions to discriminate nondysplastic from early neoplasia in Barrett's oesophagus.

  10. Weight-based determination of fluid overload status and mortality in pediatric intensive care unit patients requiring continuous renal replacement therapy

    PubMed Central

    Selewski, David T.; Cornell, Timothy T.; Lombel, Rebecca M.; Blatt, Neal B.; Han, Yong Y.; Mottes, Theresa; Kommareddi, Mallika; Kershaw, David B.; Shanley, Thomas P.; Heung, Michael

    2012-01-01

    Purpose In pediatric intensive care unit (PICU) patients, fluid overload (FO) at initiation of continuous renal replacement therapy (CRRT) has been reported to be an independent risk factor for mortality. Previous studies have calculated FO based on daily fluid balance during ICU admission, which is labor intensive and error prone. We hypothesized that a weight-based definition of FO at CRRT initiation would correlate with the fluid balance method and prove predictive of outcome. Methods This is a retrospective single-center review of PICU patients requiring CRRT from July 2006 through February 2010 (n = 113). We compared the degree of FO at CRRT initiation using the standard fluid balance method versus methods based on patient weight changes assessed by both univariate and multivariate analyses. Results The degree of fluid overload at CRRT initiation was significantly greater in nonsurvivors, irrespective of which method was used. The univariate odds ratio for PICU mortality per 1% increase in FO was 1.056 [95% confidence interval (CI) 1.025, 1.087] by the fluid balance method, 1.044 (95% CI 1.019, 1.069) by the weight-based method using PICU admission weight, and 1.045 (95% CI 1.022, 1.07) by the weight-based method using hospital admission weight. On multivariate analyses, all three methods approached significance in predicting PICU survival. Conclusions Our findings suggest that weight-based definitions of FO are useful in defining FO at CRRT initiation and are associated with increased mortality in a broad PICU patient population. This study provides evidence for a more practical weight-based definition of FO that can be used at the bedside. PMID:21533569

  11. Synthesis and properties of graphene oxide/graphene nanostructures

    NASA Astrophysics Data System (ADS)

    Kapitanova, O. O.; Panin, G. N.; Baranov, A. N.; Kang, T. W.

    2012-05-01

    We report preparation of graphene oxide (GO)/graphene (G) nanostructures and their structural, optical and electrical properties. GO was synthesized through oxidation of graphite by using the modified Hummer's method, in which a long oxidation time was combined with a highly effective method for purifying the reaction products. The obtained GO was partially reduced (r-GO) by adding ascorbic acid and thermal annealing. An electrical reduction/oxidation process in r-GO under an electric field was used to form and control the GO/G nanostructures and the potential barrier at the interface. After the treatment, the ratio of the intensity of peak G (1578 cm-1) to that of peak D (1357 cm-1) in Raman spectra of the samples is increased, which is attributed to an increase in the ratio between the sp2 and sp3 regions. The electrical and the luminescence characteristics of the GO/G nanostructures were investigated.

  12. Rapid analysis of pharmaceutical drugs using LIBS coupled with multivariate analysis.

    PubMed

    Tiwari, P K; Awasthi, S; Kumar, R; Anand, R K; Rai, P K; Rai, A K

    2018-02-01

    Type 2 diabetes drug tablets containing voglibose having dose strengths of 0.2 and 0.3 mg of various brands have been examined, using laser-induced breakdown spectroscopy (LIBS) technique. The statistical methods such as the principal component analysis (PCA) and the partial least square regression analysis (PLSR) have been employed on LIBS spectral data for classifying and developing the calibration models of drug samples. We have developed the ratio-based calibration model applying PLSR in which relative spectral intensity ratios H/C, H/N and O/N are used. Further, the developed model has been employed to predict the relative concentration of element in unknown drug samples. The experiment has been performed in air and argon atmosphere, respectively, and the obtained results have been compared. The present model provides rapid spectroscopic method for drug analysis with high statistical significance for online control and measurement process in a wide variety of pharmaceutical industrial applications.

  13. Development of vulnerability curves to typhoon hazards based on insurance policy and claim dataset

    NASA Astrophysics Data System (ADS)

    Mo, Wanmei; Fang, Weihua; li, Xinze; Wu, Peng; Tong, Xingwei

    2016-04-01

    Vulnerability refers to the characteristics and circumstances of an exposure that make it vulnerable to the effects of some certain hazards. It can be divided into physical vulnerability, social vulnerability, economic vulnerabilities and environmental vulnerability. Physical vulnerability indicates the potential physical damage of exposure caused by natural hazards. Vulnerability curves, quantifying the loss ratio against hazard intensity with a horizontal axis for the intensity and a vertical axis for the Mean Damage Ratio (MDR), is essential to the vulnerability assessment and quantitative evaluation of disasters. Fragility refers to the probability of diverse damage states under different hazard intensity, revealing a kind of characteristic of the exposure. Fragility curves are often used to quantify the probability of a given set of exposure at or exceeding a certain damage state. The development of quantitative fragility and vulnerability curves is the basis of catastrophe modeling. Generally, methods for quantitative fragility and vulnerability assessment can be categorized into empirical, analytical and expert opinion or judgment-based ones. Empirical method is one of the most popular methods and it relies heavily on the availability and quality of historical hazard and loss dataset, which has always been a great challenge. Analytical method is usually based on the engineering experiments and it is time-consuming and lacks built-in validation, so its credibility is also sometimes criticized widely. Expert opinion or judgment-based method is quite effective in the absence of data but the results could be too subjective so that the uncertainty is likely to be underestimated. In this study, we will present the fragility and vulnerability curves developed with empirical method based on simulated historical typhoon wind, rainfall and induced flood, and insurance policy and claim datasets of more than 100 historical typhoon events. Firstly, an insurance exposure classification system is built according to structure type, occupation type and insurance coverage. Then MDR estimation method based on considering insurance policy structure and claim information is proposed and validated. Following that, fragility and vulnerability curves of the major exposure types for construction, homeowner insurance and enterprise property insurance are fitted with empirical function based on the historical dataset. The results of this study can not only help understand catastrophe risk and mange insured disaster risks, but can also be applied in other disaster risk reduction efforts.

  14. Properties of Au/Copper oxide nanocomposite prepared by green laser irradiation of the mixture of individual suspensions

    NASA Astrophysics Data System (ADS)

    Aazadfar, Parvaneh; Solati, Elmira; Dorranian, Davoud

    2018-04-01

    The fundamental wavelength of a Q-switched pulsed Nd:YAG laser was employed to produce Au and copper oxide nanoparticles via pulsed laser ablation method in water. Different volumetric ratio of nanoparticles were mixed and irradiated by the second harmonic pulses of the Nd:YAG laser to prepare Au/Copper oxide nanocomposite. The experimental investigation was dedicated to study the properties of Au/Copper oxide nanocomposite as a function of volumetric ratio of Au nanoparticles and copper oxide nanoparticles. Nanocomposites of Au and copper oxide were found almost spherical in shape. Adhesion of spherical nanostructure in Au/Copper oxide nanocomposites was decreased with increasing the concentration of Au nanoparticles. Crystalline phase of the Au/Copper oxide nanocomposites differs with the change in the volumetric ratio of Au and copper oxide nanoparticles. The intensity of surface plasmon resonance of Au nanoparticles was decreased after irradiation. Au/Copper oxide nanocomposites suspensions have emissions in the visible range. Results reveal that green laser irradiation of nanoparticle suspensions is an appropriate method to synthesize Au based nanocomposites with controlled composition and size.

  15. Vertically Oriented Graphene Electrochemical Double Layer Capacitor with Very Fast Dynamic Response

    DTIC Science & Technology

    2013-01-01

    cauliflower type of morphology (see Figure A-2c). Figure A-3. (a) The intensity of D to G peak ratio in Raman spectra and the thickness (height) of...in a random, cauliflower type of morphology (see Figure A-2c). Figure A-2. (a) The intensity of D to G peak ratio in Raman spectra and the

  16. The existence of imidazoline corrosion inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, J.A.; Valone, F.W.

    1985-05-01

    Spectroscopic methods, i.e., Fourier transform infrared (FT-IR), carbon-13 nuclear magnetic reasonance (/sup 13/C NMR), and ultraviolet (UV) spectroscopy, were used to investigate the actual chemical composition of oilfield corrosion inhibitors. Inhibitor formulations consisting of an amide or imidazoline reacted with a dimer-trimer acid, along with an ethoxylated surfactant and an aromatic solvent, were used for these studies. /sup 13/C NMR and FT-IR spectra of these inhibitors, as well as spectra of pure imidazolines, showed that the imidazoline functional group was fairly rapidly hydrolyzed to the amide form. For instance, in FT-IR studies, the imine functional group decreased in intensity asmore » a function of time. Coincident with this was an increase in the intensities of the vibrational resonances attributed to the amide functionality. The relative molar ratio of imidazoline to amide in a corrosion inhibitor could be calculated via UV spectroscopy. Within a 20 day interval after inhibitor synthesis, this ratio decreased by a factor greater than 20. These results, as well as a discussion of their economic impact on oilfield corrosion inhibitor formulation, are presented in this paper.« less

  17. Laser-induced breakdown spectroscopy for in-cylinder equivalence ratio measurements in laser-ignited natural gas engines.

    PubMed

    Joshi, Sachin; Olsen, Daniel B; Dumitrescu, Cosmin; Puzinauskas, Paulius V; Yalin, Azer P

    2009-05-01

    In this contribution we present the first demonstration of simultaneous use of laser sparks for engine ignition and laser-induced breakdown spectroscopy (LIBS) measurements of in-cylinder equivalence ratios. A 1064 nm neodynium yttrium aluminum garnet (Nd:YAG) laser beam is used with an optical spark plug to ignite a single cylinder natural gas engine. The optical emission from the combustion initiating laser spark is collected through the optical spark plug and cycle-by-cycle spectra are analyzed for H(alpha)(656 nm), O(777 nm), and N(742 nm, 744 nm, and 746 nm) neutral atomic lines. The line area ratios of H(alpha)/O(777), H(alpha)/N(746), and H(alpha)/N(tot) (where N(tot) is the sum of areas of the aforementioned N lines) are correlated with equivalence ratios measured by a wide band universal exhaust gas oxygen (UEGO) sensor. Experiments are performed for input laser energy levels of 21 mJ and 26 mJ, compression ratios of 9 and 11, and equivalence ratios between 0.6 and 0.95. The results show a linear correlation (R(2) > 0.99) of line intensity ratio with equivalence ratio, thereby suggesting an engine diagnostic method for cylinder resolved equivalence ratio measurements.

  18. Impact of earthquakes on sex ratio at birth: Eastern Marmara earthquakes

    PubMed Central

    Doğer, Emek; Çakıroğlu, Yiğit; Köpük, Şule Yıldırım; Ceylan, Yasin; Şimşek, Hayal Uzelli; Çalışkan, Eray

    2013-01-01

    Objective: Previous reports suggest that maternal exposure to acute stress related to earthquakes affects the sex ratio at birth. Our aim was to examine the change in sex ratio at birth after Eastern Marmara earthquake disasters. Material and Methods: This study was performed using the official birth statistics from January 1997 to December 2002 – before and after 17 August 1999, the date of the Golcuk Earthquake – supplied from the Turkey Statistics Institute. The secondary sex ratio was expressed as the male proportion at birth, and the ratio of both affected and unaffected areas were calculated and compared on a monthly basis using data from gender with using the Chi-square test. Results: We observed significant decreases in the secondary sex ratio in the 4th and 8th months following an earthquake in the affected region compared to the unaffected region (p= 0.001 and p= 0.024). In the earthquake region, the decrease observed in the secondary sex ratio during the 8th month after an earthquake was specific to the period after the earthquake. Conclusion: Our study indicated a significant reduction in the secondary sex ratio after an earthquake. With these findings, events that cause sudden intense stress such as earthquakes can have an effect on the sex ratio at birth. PMID:24592082

  19. When is critical care medicine cost-effective? A systematic review of the cost-effectiveness literature.

    PubMed

    Talmor, Daniel; Shapiro, Nathan; Greenberg, Dan; Stone, Patricia W; Neumann, Peter J

    2006-11-01

    Receiving care in an intensive care unit can greatly influence patients' survival and quality of life. Such treatments can, however, be extremely resource intensive. Therefore, it is increasingly important to understand the costs and consequences associated with interventions aimed at reducing mortality and morbidity of critically ill patients. Cost-effectiveness analyses (CEAs) have become increasingly common to aid decisions about the allocation of scarce healthcare resources. To identify published original CEAs presenting cost/quality-adjusted life year or cost/life-year ratios for treatments used in intensive care units, to summarize the results in an accessible format, and to identify areas in critical care medicine that merit further economic evaluation. We conducted a systematic search of the English-language literature for original CEAs of critical care interventions published from 1993 through 2003. We collected data on the target population, therapy or program, study results, analytic methods employed, and the cost-effectiveness ratios presented. We identified 19 CEAs published through 2003 with 48 cost-effectiveness ratios pertaining to treatment of severe sepsis, acute respiratory failure, and general critical care interventions. These ratios ranged from cost saving to 958,423 US dollars/quality-adjusted life year and from 1,150 to 575,054 US dollars/life year gained. Many studies reported favorable cost-effectiveness profiles (i.e., below 50,000 US dollars/life year or quality-adjusted life year). Specific interventions such as activated protein C for patients with severe sepsis have been shown to provide good value for money. However, overall there is a paucity of CEA literature on the management of the critically ill, and further high-quality CEA is needed. In particular, research should focus on costly interventions such as 24-hr intensivist availability, early goal-directed therapy, and renal replacement therapy. Recent guidelines for the conduct of CEAs in critical care may increase the number and improve the quality of future CEAs.

  20. Compact point-detection fluorescence spectroscopy system for quantifying intrinsic fluorescence redox ratio in brain cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Liu, Quan; Grant, Gerald; Li, Jianjun; Zhang, Yan; Hu, Fangyao; Li, Shuqin; Wilson, Christy; Chen, Kui; Bigner, Darell; Vo-Dinh, Tuan

    2011-03-01

    We report the development of a compact point-detection fluorescence spectroscopy system and two data analysis methods to quantify the intrinsic fluorescence redox ratio and diagnose brain cancer in an orthotopic brain tumor rat model. Our system employs one compact cw diode laser (407 nm) to excite two primary endogenous fluorophores, reduced nicotinamide adenine dinucleotide, and flavin adenine dinucleotide. The spectra were first analyzed using a spectral filtering modulation method developed previously to derive the intrinsic fluorescence redox ratio, which has the advantages of insensitivty to optical coupling and rapid data acquisition and analysis. This method represents a convenient and rapid alternative for achieving intrinsic fluorescence-based redox measurements as compared to those complicated model-based methods. It is worth noting that the method can also extract total hemoglobin concentration at the same time but only if the emission path length of fluorescence light, which depends on the illumination and collection geometry of the optical probe, is long enough so that the effect of absorption on fluorescence intensity due to hemoglobin is significant. Then a multivariate method was used to statistically classify normal tissues and tumors. Although the first method offers quantitative tissue metabolism information, the second method provides high overall classification accuracy. The two methods provide complementary capabilities for understanding cancer development and noninvasively diagnosing brain cancer. The results of our study suggest that this portable system can be potentially used to demarcate the elusive boundary between a brain tumor and the surrounding normal tissue during surgical resection.

  1. Performance of irradiated CVD diamond micro-strip sensors

    NASA Astrophysics Data System (ADS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S. V.; Thomson, G. B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15/cm 2) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p/ cm2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π/ cm2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  2. A new high intensity and short-pulse molecular beam valve

    NASA Astrophysics Data System (ADS)

    Yan, B.; Claus, P. F. H.; van Oorschot, B. G. M.; Gerritsen, L.; Eppink, A. T. J. B.; van de Meerakker, S. Y. T.; Parker, D. H.

    2013-02-01

    In this paper, we report on the design and performance of a new home-built pulsed gas valve, which we refer to as the Nijmegen Pulsed Valve (NPV). The main output characteristics include a short pulse width (as short as 20 μs) combined with operating rates up to 30 Hz. The operation principle of the NPV is based on the Lorentz force created by a pulsed current passing through an aluminum strip located within a magnetic field, which opens the nozzle periodically. The amplitude of displacement of the opening mechanism is sufficient to allow the use of nozzles with up to 1.0 mm diameter. To investigate the performance of the valve, several characterizations were performed with different experimental methods. First, a fast ionization gauge was used to measure the beam intensity of the free jet emanating from the NPV. We compare free jets from the NPV with those from several other pulsed valves in current use in our laboratory. Results showed that a high intensity and short pulse-length beam could be generated by the new valve. Second, the NPV was tested in combination with a skimmer, where resonance enhanced multiphoton ionization combined with velocity map imaging was used to show that the NPV was able to produce a pulsed molecular beam with short pulse duration (˜20 μs using 0.1% NO/He at 6 bars) and low rotational temperature (˜1 K using 0.5% NO/Ar at 6 bars). Third, a novel two-point pump-probe method was employed which we label double delay scan. This method allows a full kinematic characterization of the molecular beam, including accurate speed ratios at different temporal positions. It was found that the speed ratio was maximum (S = 50 using 0.1% NO/He at 3 bars) at the peak position of the molecular beam and decreased when it was on the leading or falling edge.

  3. K and L X-ray production cross sections and intensity ratios of rare-earth elements for proton impact in the energy range 20-25 MeV

    NASA Astrophysics Data System (ADS)

    Hajivaliei, M.; Puri, Sanjiv; Garg, M. L.; Mehta, D.; Kumar, A.; Chamoli, S. K.; Avasthi, D. K.; Mandal, A.; Nandi, T. K.; Singh, K. P.; Singh, Nirmal; Govil, I. M.

    2000-02-01

    The Kα1, Kα2, Kβ1, Kβ2, and the Lℓ, Lα, Lβ and Lγ X-ray production (XRP) cross sections and the relative intensity ratios for seven rare-earth elements with 60⩽Z⩽70 have been measured for 20, 22 and 25 MeV proton impact. The experimental data on the L-shell XRP cross sections for high energy proton impact have been reported for the first time. The measured XRP cross sections for all the K-lines and the relative intensity ratios Kα1/Kα, Kα2/Kα, Kβ1/Kα, Kβ2/Kα and Kβ/Kα are in good agreement with the theoretical ones calculated using ECPSSR ionisation cross sections for all the elements investigated at the three beam energies. The Lℓ, Lα, Lβ, and Lγ XRP cross sections measured at the three proton energies are found to be in general higher than the theoretical values calculated using the ECPSSR ionisation cross sections and the RDHS model-based Li sub-shell fluorescence and Coster-Kronig (CK) yields. The measured relative intensity ratios Lβ/Lα, and Lγ/Lα exhibit good agreement with the theoretical ones for all the elements under investigation, whereas the Lℓ/Lα ratios are found to deviate from the theoretical ones.

  4. Position-specific incorporation of fluorescent non-natural amino acids into maltose-binding protein for detection of ligand binding by FRET and fluorescence quenching.

    PubMed

    Iijima, Issei; Hohsaka, Takahiro

    2009-04-17

    Position-specific incorporation of fluorescent groups is a useful method for analysis of the functions and structures of proteins. We have developed a method for the incorporation of visible-wavelength-fluorescent non-natural amino acids into proteins in a cell-free translation system. Using this technique, we introduced one or two BODIPY-linked amino acids into maltose-binding protein (MBP) to obtain MBP derivatives showing ligand-dependent changes in fluorescence intensity or intensity ratio. BODIPY-FL-aminophenylalanine was incorporated in place of 15 tyrosines, as well as the N-terminal Lys1, and the C-terminal Lys370 of MBP. Fluorescence measurements revealed that MBP containing a BODIPY-FL moiety in place of Tyr210 showed a 13-fold increase in fluorescence upon binding of maltose. Tryptophan-to-phenylalanine substitutions suggest that the increase in fluorescence was the result of a decrease in the quenching of BODIPY-FL by tryptophan located around the binding site. MBP containing a BODIPY-558 moiety also showed a maltose-dependent increase in fluorescence. BODIPY-FL was then additionally incorporated in place of Lys1 of the BODIPY-558-containing MBP as a response to the amber codon. Fluorescence measurements with excitation of BODIPY-FL showed a large change in fluorescence intensity ratio (0.13 to 1.25) upon binding of maltose; this change can be attributed to fluorescence resonance energy transfer (FRET) and maltose-dependent quenching of BODIPY-558. These results demonstrate the usefulness of the position-specific incorporation of fluorescent amino acids in the fluorescence-based detection of protein functions.

  5. Combining functional weed ecology and crop stable isotope ratios to identify cultivation intensity: a comparison of cereal production regimes in Haute Provence, France and Asturias, Spain.

    PubMed

    Bogaard, Amy; Hodgson, John; Nitsch, Erika; Jones, Glynis; Styring, Amy; Diffey, Charlotte; Pouncett, John; Herbig, Christoph; Charles, Michael; Ertuğ, Füsun; Tugay, Osman; Filipovic, Dragana; Fraser, Rebecca

    This investigation combines two independent methods of identifying crop growing conditions and husbandry practices-functional weed ecology and crop stable carbon and nitrogen isotope analysis-in order to assess their potential for inferring the intensity of past cereal production systems using archaeobotanical assemblages. Present-day organic cereal farming in Haute Provence, France features crop varieties adapted to low-nutrient soils managed through crop rotation, with little to no manuring. Weed quadrat survey of 60 crop field transects in this region revealed that floristic variation primarily reflects geographical differences. Functional ecological weed data clearly distinguish the Provence fields from those surveyed in a previous study of intensively managed spelt wheat in Asturias, north-western Spain: as expected, weed ecological data reflect higher soil fertility and disturbance in Asturias. Similarly, crop stable nitrogen isotope values distinguish between intensive manuring in Asturias and long-term cultivation with minimal manuring in Haute Provence. The new model of cereal cultivation intensity based on weed ecology and crop isotope values in Haute Provence and Asturias was tested through application to two other present-day regimes, successfully identifying a high-intensity regime in the Sighisoara region, Romania, and low-intensity production in Kastamonu, Turkey. Application of this new model to Neolithic archaeobotanical assemblages in central Europe suggests that early farming tended to be intensive, and likely incorporated manuring, but also exhibited considerable variation, providing a finer grained understanding of cultivation intensity than previously available.

  6. Rapid Estimation of Astaxanthin and the Carotenoid-to-Chlorophyll Ratio in the Green Microalga Chromochloris zofingiensis Using Flow Cytometry.

    PubMed

    Chen, Junhui; Wei, Dong; Pohnert, Georg

    2017-07-19

    The green microalga Chromochloris zofingiensis can accumulate significant amounts of valuable carotenoids, mainly natural astaxanthin, a product with applications in functional food, cosmetics, nutraceuticals, and with potential therapeutic value in cardiovascular and neurological diseases. To optimize the production of astaxanthin, it is essential to monitor the content of astaxanthin in algal cells during cultivation. The widely used HPLC (high-performance liquid chromatography) method for quantitative astaxanthin determination is time-consuming and laborious. In the present work, we present a method using flow cytometry (FCM) for in vivo determination of the astaxanthin content and the carotenoid-to-chlorophyll ratio (Car/Chl) in mixotrophic C. zofingiensis . The method is based on the assessment of fluorescent characteristics of cellular pigments. The mean fluorescence intensity (MFI) of living cells was determined by FCM to monitor pigment formation based on the correlation between MFI detected in particular channels (FL1: 533 ± 15 nm; FL2: 585 ± 20 nm; FL3: >670 nm) and pigment content in algal cells. Through correlation and regression analysis, a linear relationship was observed between MFI in FL2 (band-pass filter, emission at 585 nm in FCM) and astaxanthin content (in HPLC) and applied for predicting astaxanthin content. With similar procedures, the relationships between MFI in different channels and Car/Chl ratio in mixotrophic C. zofingiensis were also determined. Car/Chl ratios could be estimated by the ratios of MFI (FL1/FL3, FL2/FL3). FCM is thus a highly efficient and feasible method for rapid estimation of astaxanthin content in the green microalga C. zofingiensis . The rapid FCM method is complementary to the current HPLC method, especially for rapid evaluation and prediction of astaxanthin formation as it is required during the high-throughput culture in the laboratory and mass cultivation in industry.

  7. Rapid Estimation of Astaxanthin and the Carotenoid-to-Chlorophyll Ratio in the Green Microalga Chromochloris zofingiensis Using Flow Cytometry

    PubMed Central

    Chen, Junhui; Pohnert, Georg

    2017-01-01

    The green microalga Chromochloris zofingiensis can accumulate significant amounts of valuable carotenoids, mainly natural astaxanthin, a product with applications in functional food, cosmetics, nutraceuticals, and with potential therapeutic value in cardiovascular and neurological diseases. To optimize the production of astaxanthin, it is essential to monitor the content of astaxanthin in algal cells during cultivation. The widely used HPLC (high-performance liquid chromatography) method for quantitative astaxanthin determination is time-consuming and laborious. In the present work, we present a method using flow cytometry (FCM) for in vivo determination of the astaxanthin content and the carotenoid-to-chlorophyll ratio (Car/Chl) in mixotrophic C. zofingiensis. The method is based on the assessment of fluorescent characteristics of cellular pigments. The mean fluorescence intensity (MFI) of living cells was determined by FCM to monitor pigment formation based on the correlation between MFI detected in particular channels (FL1: 533 ± 15 nm; FL2: 585 ± 20 nm; FL3: >670 nm) and pigment content in algal cells. Through correlation and regression analysis, a linear relationship was observed between MFI in FL2 (band-pass filter, emission at 585 nm in FCM) and astaxanthin content (in HPLC) and applied for predicting astaxanthin content. With similar procedures, the relationships between MFI in different channels and Car/Chl ratio in mixotrophic C. zofingiensis were also determined. Car/Chl ratios could be estimated by the ratios of MFI (FL1/FL3, FL2/FL3). FCM is thus a highly efficient and feasible method for rapid estimation of astaxanthin content in the green microalga C. zofingiensis. The rapid FCM method is complementary to the current HPLC method, especially for rapid evaluation and prediction of astaxanthin formation as it is required during the high-throughput culture in the laboratory and mass cultivation in industry. PMID:28753934

  8. Factors influencing the ablative efficiency of high intensity focused ultrasound (HIFU) treatment for adenomyosis: A retrospective study.

    PubMed

    Gong, Chunmei; Yang, Bin; Shi, Yarong; Liu, Zhongqiong; Wan, Lili; Zhang, Hong; Jiang, Denghua; Zhang, Lian

    2016-08-01

    Objectives The aim of this study was to investigate factors affecting ablative efficiency of high intensity focused ultrasound (HIFU) for adenomyosis. Materials and methods In all, 245 patients with adenomyosis who underwent ultrasound guided HIFU (USgHIFU) were retrospectively reviewed. All patients underwent dynamic contrast-enhanced magnetic resonance imaging (MRI) before and after HIFU treatment. The non-perfused volume (NPV) ratio, energy efficiency factor (EEF) and greyscale change were set as dependent variables, while the factors possibly affecting ablation efficiency were set as independent variables. These variables were used to build multiple regression models. Results A total of 245 patients with adenomyosis successfully completed HIFU treatment. Enhancement type on T1 weighted image (WI), abdominal wall thickness, volume of adenomyotic lesion, the number of hyperintense points, location of the uterus, and location of adenomyosis all had a linear relationship with the NPV ratio. Distance from skin to the adenomyotic lesion's ventral side, enhancement type on T1WI, volume of adenomyotic lesion, abdominal wall thickness, and signal intensity on T2WI all had a linear relationship with EEF. Location of the uterus and abdominal wall thickness also both had a linear relationship with greyscale change. Conclusion The enhancement type on T1WI, signal intensity on T2WI, volume of adenomyosis, location of the uterus and adenomyosis, number of hyperintense points, abdominal wall thickness, and distance from the skin to the adenomyotic lesion's ventral side can all be used as predictors of HIFU for adenomyosis.

  9. Application of laser Raman spectroscopy to dental diagnosis

    NASA Astrophysics Data System (ADS)

    Izawa, Takahiro; Wakaki, Moriaki

    2005-03-01

    The aim of this research is related with the diagnosis of caries by use of a laser. We study the fundamental characterization of the diagnosis method using both fluorescence and Raman scattering spectroscopy. We try to evaluate the possibility of the caries diagnosis using Raman spectroscopy and its clinical application. We focus on the PO34- ion that flows out with the dissolution of hydroxyapatite (HAp), and the fluorescence that increases in connection with caries. The Raman line of P-O vibration is overlapped on the continuous, background spectrum by fluorescence. Consequently, we try to find out the correlation between a healthy part and a carious part by analyzing both fluorescence and Raman spectra. It was found that Raman intensity of HAp at carious lesion was weaker than those of healthy parts and the florescence intensity at the same portions was stronger. We have obtained the feasibility to estimate the degree of caries and health condition by deriving the ratio between Raman and florescence intensity. And the trial measurements in vivo were carried out to verify the availability of the method by using a fiber probe type multi channel Raman spectrometer. The process of remineralization is under researching for the development of preventive medicine.

  10. An Automatic Method for Generating an Unbiased Intensity Normalizing Factor in Positron Emission Tomography Image Analysis After Stroke.

    PubMed

    Nie, Binbin; Liang, Shengxiang; Jiang, Xiaofeng; Duan, Shaofeng; Huang, Qi; Zhang, Tianhao; Li, Panlong; Liu, Hua; Shan, Baoci

    2018-06-07

    Positron emission tomography (PET) imaging of functional metabolism has been widely used to investigate functional recovery and to evaluate therapeutic efficacy after stroke. The voxel intensity of a PET image is the most important indicator of cellular activity, but is affected by other factors such as the basal metabolic ratio of each subject. In order to locate dysfunctional regions accurately, intensity normalization by a scale factor is a prerequisite in the data analysis, for which the global mean value is most widely used. However, this is unsuitable for stroke studies. Alternatively, a specified scale factor calculated from a reference region is also used, comprising neither hyper- nor hypo-metabolic voxels. But there is no such recognized reference region for stroke studies. Therefore, we proposed a totally data-driven automatic method for unbiased scale factor generation. This factor was generated iteratively until the residual deviation of two adjacent scale factors was reduced by < 5%. Moreover, both simulated and real stroke data were used for evaluation, and these suggested that our proposed unbiased scale factor has better sensitivity and accuracy for stroke studies.

  11. Game and venison - meat for the modern consumer.

    PubMed

    Hoffman, L C; Wiklund, E

    2006-09-01

    This review focuses on how game meat from southern Africa and venison that are increasingly being imported into Europe and the US addresses consumer issues as pertaining to production (wild, free range or intensive production) and harvesting methods, healthiness (chemical composition, particularly fatty acid composition), and traceability. Although African game meat species are farmed extensively, deer species are farmed using extensive to intensive production systems. However, the increasingly intensive production of the cervids and the accompanying practices associated with this (castration, velvetting, feeding of balanced diets, etc.) may have a negative impact in the near future on the consumer's perception of these animals. These alternative meat species are all harvested in a sustainable manner using acceptable methods. All these species have very low muscle fat contents consisting predominantly of structural lipid components (phospholipid and cholesterol) that have high proportions of polyunsaturated fatty acids. This results in the meat having desirable polyunsaturated:saturated and n-6:n-3 fatty acid ratios. The South African traceability system is discussed briefly as an example on how these exporting countries are able to address the requirements pertaining to the import of meat as stipulated by the European Economic Community.

  12. Fading-free transmission of 124-Gb/s PDM-DMT signal over 100-km SSMF using digital carrier regeneration.

    PubMed

    Li, Cai; Hu, Rong; Yang, Qi; Luo, Ming; Li, Wei; Yu, Shaohua

    2016-01-25

    The coherent reception of intensity modulated signal has been recently widely investigated, in which the signal is recovered by the envelop detection. High linewidth tolerance is achieved with such scheme. However, strong optical carrier exists during the transmission, which degrades the optical power efficiency. In this paper, an efficient modulation scheme for discrete multi-tone (DMT) signal is proposed based on the Mach-Zehnder modulator (MZM). Different from the traditional intensity modulation, the proposed method employs both intensity and phase domain. Thus, the optical carrier power can be greatly reduced by adjusting the bias of MZM around the null point. By employing coherent detection and digital carrier regeneration (DCR), the carrier suppressed DMT signal can be recovered using envelop detection. No carrier frequency or phase estimation is required. Numerical investigations are made to demonstrate the feasibility, in which significant improvements are found for the proposed DCR method, showing great tolerance against laser linewidth and carrier power reduction. Finally, a 124-Gb/s transmission of polarization-division multiplexed DMT (PDM-DMT) signal is demonstrated over 100-km SSMF, with only -8 dB optical carrier to signal power ratio (CSPR).

  13. Optical temperature sensing of Er3+/Yb3+ doped LaGdO3 based on fluorescence intensity ratio and lifetime thermometry

    NASA Astrophysics Data System (ADS)

    Siaï, A.; Haro-González, P.; Horchani Naifer, K.; Férid, M.

    2018-02-01

    The investigation of the fluorescence intensity ratio and the lifetime thermometry techniques for two rare earth perovskites-type oxide (LaGdO3:Er3+ and LaGdO3:Er3+/Yb3+) has been carried out. We have demonstrated that the intensity ratio of thermally coupled levels of erbium (2H11/2 and 4S3/2) is temperature dependant in the range from 283 to 393 K. The sensitivity parameter was found to reach a maximum value of 31 × 10-4 K-1 and 34 × 10-4 K-1 at 393 K and the temperature resolution to be equivalent to 1.61 and 3.1 K, for Er3+ and Er3+/Yb3+ doped oxide, respectively. By studying the temperature dependence of the normalized lifetimes in the range from 293 to 348 K, we proved that the sensitivity of the green emission (4S3/2) is higher than the red one (4F9/2) for both samples, and that it increases from 144 × 10-4 K-1 for LaGdO3:Er3+ to 179 × 10-4 K-1 for LaGdO3:Er3+/Yb3+. The thermal coefficients were quite large in comparison to those calculated for different luminescent materials and reported in literature. The repeatability of measurements was tested by performing heating and cooling cycles for both methods and the results show that these optical techniques have a good repeatability performance. Hence, the LaGdO3: Er3+, Yb3+ oxide has a precise and a satisfying sensitivity associated to a good thermal and chemical stability, suggesting that it can be a potential candidate in temperature sensing.

  14. Comparison of different volumes of high intensity interval training on cardiac autonomic function in sedentary young women.

    PubMed

    Bhati, Pooja; Bansal, Vishal; Moiz, Jamal Ali

    2017-08-24

    Purpose The present study was conducted to compare the effects of low volume of high intensity interval training (LVHIIT) and high volume of high intensity interval training (HVHIIT) on heart rate variability (HRV) as a primary outcome measure, and on maximum oxygen consumption (VO2max), body composition, and lower limb muscle strength as secondary outcome measures, in sedentary young women. Methods Thirty-six participants were recruited in this study. The LVHIIT group (n = 17) performed one 4-min bout of treadmill running at 85%-95% maximum heart rate (HRmax), followed by 3 min of recovery by running at 70% HRmax, three times per week for 6 weeks. The HVHIIT group (n = 15) performed four times 4-min bouts of treadmill running at 85%-95% HRmax, interspersed with 3-min of recovery by running at 70% HRmax, 3 times per week for 6 weeks. All criterion measures were measured before and after training in both the groups. Results Due to attrition of four cases, data of 32 participants was used for analysis. A significant increase in high frequency (HF) power (p < 0.001) and decrease in the ratio of low frequency to high frequency power (LF/HF) ratio (p < 0.001) in HRV parameters, was observed post-HVHIIT, whereas, these variables did not change significantly (HF: p = 0.92, LF/HF ratio: p = 0.52) in LVHIIT group. Nevertheless, both the interventions proved equally effective in improving aerobic capacity (VO2max), body composition, and muscle strength. Conclusion The study results suggest that both LVHIIT and HVHIIT are equally effective in improving VO2max, body composition, and muscle strength, in sedentary young women. However, HVHIIT induces parasympathetic dominance as well, as measured by HRV.

  15. Citrate mediated synthesis and tuning of luminescence in Eu3+ incorporated Gd2O3 nanophosphors

    NASA Astrophysics Data System (ADS)

    Abhilash Kumar, R. G.; Gopchandran, K. G.

    2015-02-01

    Gd1.9Eu0.1O3 nanophosphors were prepared successfully by a large-scale facile solution based citrate-metal complex controlled combustion method and was systematically studied by varying the citric acid to metal cation ratio. X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), photoluminescence (PL) measurements and radiative properties were done to evaluate the crystal structure, phase formation, phase composition, surface morphology, radiative and luminescent properties of the prepared nanophosphors. Photoluminescent emission intensity of the samples can be correlated with the amount of citric acid, improved crystallinity, uniform morphology, particle size, reduced defects, and proper diffusion of Eu3+ in to the crystal structure of Gd2O3. Higher asymmetricity results in intense red emission (612 nm) due to 5D0-7F2 forced electric dipole transition and found that photoluminescence intensity is highest for the sample prepared with citric acid to metal cation ratio of 2:1. The existence of strong red emission from Gd1.9Eu0.1O3 nanophosphor corresponding to 5D0-7F2 transition (612 nm) of Eu3+ under UV light excitation make it a promising candidate for applications in bio assays, magnetic resonance imaging, deep uv LED's, solid state lighting, fluorescent lamps and flat panel displays.

  16. Impact of consanguineous marriages and degrees of inbreeding on fertility, child mortality, secondary sex ratio, selection intensity, and genetic load: a cross-sectional study from Northern India.

    PubMed

    Fareed, Mohd; Kaisar Ahmad, Mir; Azeem Anwar, Malik; Afzal, Mohammad

    2017-01-01

    The aim of our study was to understand the relationship between consanguineous marriages and reproductive outcomes. A total of 999 families were recruited from five Muslim populations of Jammu region. Family pedigrees were drawn to access the family history and inbreeding status in terms of coefficient of inbreeding (F). Fertility, mortality, secondary sex ratio, selection intensity, and lethal equivalents were measured using standard methods. The significant differences for gross fertility was found to be higher among inbred groups as compared to the unrelated families (P < 0.05) and higher mortality rates were observed among consanguineous families of all populations in comparison with the non-consanguineous family groups. Moreover, the prenatal and postnatal child mortality rates (i.e., U5MR and U18MR) have presented a persuasive increase with an upsurge in the homozygosity level. The mortality rate was found to be maximum among families with the highest value of coefficient of inbreeding (F). The selection intensity (SI) also showed inflations among families with respect to their increasing inbreeding coefficients. The greater values of lethal equivalents per gamete (LEs/gamete) were observed for autosomal inheritance in comparison with sex-linked inheritance. Our conclusive assessment brings out the deleterious consequence of consanguineous marriages on reproductive outcomes.

  17. A Candidate Tidal Disruption Event in a Quasar at z = 2.359 from Abundance Ratio Variability

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Dittmann, Alexander; Shen, Yue; Jiang, Linhua

    2018-05-01

    A small fraction of quasars show an unusually high nitrogen-to-carbon ratio (N/C) in their spectra. These “nitrogen-rich” (N-rich) quasars are a long-standing puzzle because their interstellar medium implies stellar populations with abnormally high metallicities. It has recently been proposed that N-rich quasars may result from tidal disruption events (TDEs) of stars by supermassive black holes. The rapid enhancement of nitrogen and the depletion of carbon due to the carbon–nitrogen–oxygen cycle in supersolar mass stars could naturally produce high N/C. However, the TDE hypothesis predicts that the N/C should change with time, which has never hitherto been observed. Here we report the discovery of the first N-rich quasar with rapid N/C variability that could be caused by a TDE. Two spectra separated by 1.7 years (rest-frame) show that the N III] λ1750/C III] λ1909 intensity ratio decayed by ∼86% ± 14% (1σ). Optical (rest-frame UV) light-curve and X-ray observations are qualitatively consistent with the TDE hypothesis; though, the time baseline falls short of a definitive proof. Putting the single-object discovery into context, statistical analyses of the ∼80 known N-rich quasars with high-quality archival spectra show evidence (at a 5σ significance level) of a decrease in N/C on timescales of >1 year (rest-frame) and a constant level of ionization (indicated by the C III] λ1909/C IV λ1549 intensity ratio). If confirmed, our results demonstrate the method of identifying TDE candidates in quasars via abundance ratio variability, opening a new window of TDE observations at high redshift (z > 2) with upcoming large-scale time-domain spectroscopic surveys.

  18. Probing battery chemistry with liquid cell electron energy loss spectroscopy

    DOE PAGES

    Unocic, Raymond R.; Baggetto, Loic; Veith, Gabriel M.; ...

    2015-09-15

    Electron energy loss spectroscopy (EELS) was used to determine the chemistry and oxidation state of LiMn 2O 4 and Li 4Ti 5O 12 thin film battery electrodes in liquid cells for in situ scanning/transmission electron microscopy (S/TEM). Using the L2,3 white line intensity ratio method we determine the oxidation state of Mn and Ti in a liquid electrolyte solvent and discuss experimental parameters that influence measurement sensitivity.

  19. Electro-optic fringe locking and photometric tuning using a two-stage Mach-Zehnder lithium niobate waveguide for high-contrast mid-infrared interferometry

    NASA Astrophysics Data System (ADS)

    Martin, Guillermo; Heidmann, Samuel; Rauch, Jean-Yves; Jocou, Laurent; Courjal, Nadège

    2014-03-01

    We present an optimization process to improve the rejection ratio in integrated beam combiners by locking the dark fringe and then monitoring its intensity. The method proposed here uses the electro-optic effect of lithium niobate in order to lock the dark fringe and to real-time balance the photometric flux by means of a two-stage Mach-Zehnder interferometer waveguide. By applying a control voltage on the output Y-junction, we are able to lock the phase and stay in the dark fringe, while an independent second voltage is applied on the first-stage intensity modulator, to finely balance the photometries. We have obtained a rejection ratio of 4600 (36.6 dB) at 3.39 μm in transverse electric polarization, corresponding to 99.98% fringe contrast, and shown that the system can compensate external phase perturbations (a piston variation of 100 nm) up to around 1 kHz. We also show the preliminary results of this process on wide-band modulation, where a contrast of 38% in 3.25- to 3.65-μm spectral range is obtained. These preliminary results on wide-band need to be optimized, in particular, for reducing scattered light of the device at the Y-junction. We expect this active method to be useful in high-contrast interferometry, in particular, for astronomical spatial projects actually under study.

  20. A Ratiometric Threshold for Determining Presence of Cancer During Fluorescence-guided Surgery

    PubMed Central

    Warram, Jason M; de Boer, Esther; Moore, Lindsay S.; Schmalbach, Cecelia E; Withrow, Kirk P; Carroll, William R; Richman, Joshua S; Morlandt, Anthony B; Brandwein-Gensler, Margaret; Rosenthal, Eben L

    2015-01-01

    Background&Objective Fluorescence-guided imaging to assist in identification of malignant margins has the potential to dramatically improve oncologic surgery. However a standardized method for quantitative assessment of disease-specific fluorescence has not been investigated. Introduced here is a ratiometric threshold derived from mean fluorescent tissue intensity that can be used to semi-quantitatively delineate tumor from normal tissue. Methods Open-field and a closed-field imaging devices were used to quantify fluorescence in punch biopsy tissues sampled from primary tumors collected during a phase 1 trial evaluating the safety of cetuximab-IRDye800 in patients (n=11) undergoing surgical intervention for head and neck cancer. Fluorescence ratios were calculated using mean fluorescence intensity (MFI) from punch biopsy normalized by MFI of patient-matched tissues. Ratios were compared to pathological assessment and a ratiometric threshold was established to predict presence of cancer. Results During open-field imaging using an intraoperative device, the threshold for muscle normalized tumor fluorescence was found to be 2.7, which produced a sensitivity of 90.5% and specificity of 78.6% for delineating disease tissue. The skin-normalized threshold generated greater sensitivity (92.9%) and specificity (81.0%). Conclusion Successful implementation of a semi-quantitative threshold can provide a scientific methodology for delineating disease from normal tissue during fluorescence-guided resection of cancer. PMID:26074273

  1. Experimental Investigation of Premixed Turbulent Hydrocarbon/Air Bunsen Flames

    NASA Astrophysics Data System (ADS)

    Tamadonfar, Parsa

    Through the influence of turbulence, the front of a premixed turbulent flame is subjected to the motions of eddies that leads to an increase in the flame surface area, and the term flame wrinkling is commonly used to describe it. If it is assumed that the flame front would continue to burn locally unaffected by the stretch, then the total turbulent burning velocity is expected to increase proportionally to the increase in the flame surface area caused by wrinkling. When the turbulence intensity is high enough such that the stretch due to hydrodynamics and flame curvature would influence the local premixed laminar burning velocity, then the actual laminar burning velocity (that is, flamelet consumption velocity) should reflect the influence of stretch. To address this issue, obtaining the knowledge of instantaneous flame front structures, flame brush characteristics, and burning velocities of premixed turbulent flames is necessary. Two axisymmetric Bunsen-type burners were used to produce premixed turbulent flames, and three optical measurement techniques were utilized: Particle image velocimetry to measure the turbulence statistics; Rayleigh scattering method to measure the temperature fields of premixed turbulent flames, and Mie scattering method to visualize the flame front contours of premixed turbulent flames. Three hydrocarbons (methane, ethane, and propane) were used as the fuel in the experiments. The turbulence was generated using different perforated plates mounted upstream of the burner exit. A series of comprehensive parameters including the thermal flame front thickness, characteristic flame height, mean flame brush thickness, mean volume of the turbulent flame region, two-dimensional flame front curvature, local flame front angle, two-dimensional flame surface density, wrinkled flame surface area, turbulent burning velocity, mean flamelet consumption velocity, mean turbulent flame stretch factor, mean turbulent Markstein length and number, and mean fuel consumption rate were systematically evaluated from the experimental data. The normalized preheat zone and reaction zone thicknesses decreased with increasing non-dimensional turbulence intensity in ultra-lean premixed turbulent flames under a constant equivalence ratio of 0.6, whereas they increased with increasing equivalence ratios from 0.6 to 1.0 under a constant bulk flow velocity. The normalized preheat zone and reaction zone thicknesses showed no overall trend with increasing non-dimensional longitudinal integral length scale. The normalized preheat zone and reaction zone thicknesses decreased by increasing the Karlovitz number, suggesting that increasing the total stretch rate is the controlling mechanism in the reduction of flame front thickness for the experimental conditions studied in this thesis. In general, the leading edge and half-burning surface turbulent burning velocities were enhanced with increasing equivalence ratio from lean to stoichiometric mixtures, whereas they decreased with increasing equivalence ratio for rich mixtures. These velocities were enhanced with increasing total turbulence intensity. The leading edge and half-burning surface turbulent burning velocities for lean/stoichiometric mixtures were observed to be smaller than that for rich mixtures. The mean turbulent flame stretch factor displayed a dependence on the equivalence ratio and turbulence intensity. Results show that the mean turbulent flame stretch factors for lean/stoichiometric and rich mixtures were not equal when the unstrained premixed laminar burning velocity, non-dimensional bulk flow velocity, non-dimensional turbulence intensity, and non-dimensional longitudinal integral length scale were kept constant.

  2. Evaluation on the stability of Hg in ABS disk CRM during measurements by wavelength dispersive X-ray fluorescence spectrometry.

    PubMed

    Ohata, Masaki; Kidokoro, Toshihiro; Hioki, Akiharu

    2012-01-01

    The stability of Hg in an acrylonitrile-butadiene-styrene disk certified reference material (ABS disk CRM, NMIJ CRM 8116-a) during measurements by wavelength dispersion X-ray fluorescence (WD-XRF) analysis was evaluated in this study. The XRF intensities of Hg (L(α)) and Pb (L(α)) as well as the XRF intensity ratios of Hg (L(α))/Pb (L(α)) observed under different X-ray tube current conditions as well as their irradiation time were examined to evaluate the stability of Hg in the ABS disk CRM. The observed XRF intensities and the XRF intensity ratios for up to 32 h of measurements under 80 mA of X-ray tube current condition were constant, even though the surface of the ABS disk CRM was charred by the X-ray irradiation with high current for a long time. Moreover, the measurements on Hg and Pb in the charred disks by an energy dispersive XRF (ED-XRF) spectrometer showed constant XRF intensity ratios of Hg (L(α))/Pb (L(α)). From these results, Hg in the ABS disk CRM was evaluated to be sufficiently stable for XRF analysis.

  3. Effect of Secondary Cooling Conditions on Solidification Structure and Central Macrosegregation in Continuously Cast High-Carbon Rectangular Billet

    NASA Astrophysics Data System (ADS)

    Zeng, Jie; Chen, Weiqing

    2015-10-01

    Solidification structures of high carbon rectangular billet with a size of 180 mm × 240 mm in different secondary cooling conditions were simulated using cellular automaton-finite element (CAFE) coupling model. The adequacy of the model was compared with the simulated and the actual macrostructures of 82B steel. Effects of the secondary cooling water intensity on solidification structures including the equiaxed grain ratio and the equiaxed grain compactness were discussed. It was shown that the equiaxed grain ratio and the equiaxed grain compactness changed in the opposite direction at different secondary cooling water intensities. Increasing the secondary cooling water intensity from 0.9 or 1.1 to 1.3 L/kg could improve the equiaxed grain compactness and decrease the equiaxed grain ratio. Besides, the industrial test was conducted to investigate the effect of different secondary cooling water intensities on the center carbon macrosegregation of 82B steel. The optimum secondary cooling water intensity was 0.9 L/kg, while the center carbon segregation degree was 1.10. The relationship between solidification structure and center carbon segregation was discussed based on the simulation results and the industrial test.

  4. Measurements of geomagnetically trapped alpha particles, 1968-1970. I - Quiet time distributions

    NASA Technical Reports Server (NTRS)

    Krimigis, S. M.; Verzariu, P.

    1973-01-01

    Results of observations of geomagnetically trapped alpha particles over the energy range from 1.18 to 8 MeV performed with the aid of the Injun 5 polar-orbiting satellite during the period from September 1968 to May 1970. Following a presentation of a time history covering this entire period, a detailed analysis is made of the magnetically quiet period from Feb. 11 to 28, 1970. During this period the alpha particle fluxes and the intensity ratio of alpha particles to protons attained their lowest values in approximately 20 months; the alpha particle intensity versus L profile was most similar to the proton profile at the same energy per nucleon interval; the intensity ratio was nearly constant as a function of L in the same energy per nucleon representation, but rose sharply with L when computed in the same total energy interval; the variation of alpha particle intensity with B suggested a steep angular distribution at small equatorial pitch angles, while the intensity ratio showed little dependence on B; and the alpha particle spectral parameter showed a markedly different dependence on L from the equivalent one for protons.

  5. Tables of stark level transition probabilities and branching ratios in hydrogen-like atoms

    NASA Technical Reports Server (NTRS)

    Omidvar, K.

    1980-01-01

    The transition probabilities which are given in terms of n prime k prime and n k are tabulated. No additional summing or averaging is necessary. The electric quantum number k plays the role of the angular momentum quantum number l in the presence of an electric field. The branching ratios between stark levels are also tabulated. Necessary formulas for the transition probabilities and branching ratios are given. Symmetries are discussed and selection rules are given. Some disagreements for some branching ratios are found between the present calculation and the measurement of Mark and Wierl. The transition probability multiplied by the statistical weight of the initial state is called the static intensity J sub S, while the branching ratios are called the dynamic intensity J sub D.

  6. Effect of Game Management on Wild Red-Legged Partridge Abundance

    PubMed Central

    Díaz-Fernández, Silvia; Arroyo, Beatriz; Casas, Fabián; Martinez-Haro, Monica; Viñuela, Javier

    2013-01-01

    The reduction of game and fish populations has increased investment in management practices. Hunting and fishing managers use several tools to maximize harvest. Managers need to know the impact their management has on wild populations. This issue is especially important to improve management efficacy and biodiversity conservation. We used questionnaires and field bird surveys in 48 hunting estates to assess whether red-legged partridge Alectoris rufa young/adult ratio and summer abundance were related to the intensity of management (provision of supplementary food and water, predator control and releases of farm-bred partridges), harvest intensity or habitat in Central Spain. We hypothesized that partridge abundance would be higher where management practices were applied more intensively. Variation in young/adult ratio among estates was best explained by habitat, year and some management practices. Density of feeders and water points had a positive relationship with this ratio, while the density of partridges released and magpies controlled were negatively related to it. The variables with greatest relative importance were feeders, releases and year. Variations in post-breeding red-legged partridge abundance among estates were best explained by habitat, year, the same management variables that influenced young/adult ratio, and harvest intensity. Harvest intensity was negatively related to partridge abundance. The other management variables had the same type of relationship with abundance as with young/adult ratio, except magpie control. Variables with greatest relative importance were habitat, feeders, water points, releases and harvest intensity. Our study suggests that management had an overall important effect on post-breeding partridge abundance. However, this effect varied among tools, as some had the desired effect (increase in partridge abundance), whereas others did not or even had a negative relationship (such as release of farm-reared birds) and can be thus considered inefficient or even detrimental. We advise reconsidering their use from both ecological and economical points of view. PMID:23840515

  7. Permutation methods for the structured exploratory data analysis (SEDA) of familial trait values.

    PubMed

    Karlin, S; Williams, P T

    1984-07-01

    A collection of functions that contrast familial trait values between and across generations is proposed for studying transmission effects and other collateral influences in nuclear families. Two classes of structured exploratory data analysis (SEDA) statistics are derived from ratios of these functions. SEDA-functionals are the empirical cumulative distributions of the ratio of the two contrasts computed within each family. SEDA-indices are formed by first averaging the numerator and denominator contrasts separately over the population and then forming their ratio. The significance of SEDA results are determined by a spectrum of permutation techniques that selectively shuffle the trait values across families. The process systematically alters certain family structure relationships while keeping other familial relationships intact. The methodology is applied to five data examples of plasma total cholesterol concentrations, reported height values, dermatoglyphic pattern intensity index scores, measurements of dopamine-beta-hydroxylase activity, and psychometric cognitive test results.

  8. On the Fast Evaluation Method of Temperature and Gas Mixing Ratio Weighting Functions for Remote Sensing of Planetary Atmospheres in Thermal IR and Microwave

    NASA Technical Reports Server (NTRS)

    Ustinov, E. A.

    1999-01-01

    Evaluation of weighting functions in the atmospheric remote sensing is usually the most computer-intensive part of the inversion algorithms. We present an analytic approach to computations of temperature and mixing ratio weighting functions that is based on our previous results but the resulting expressions use the intermediate variables that are generated in computations of observable radiances themselves. Upwelling radiances at the given level in the atmosphere and atmospheric transmittances from space to the given level are combined with local values of the total absorption coefficient and its components due to absorption of atmospheric constituents under study. This makes it possible to evaluate the temperature and mixing ratio weighting functions in parallel with evaluation of radiances. This substantially decreases the computer time required for evaluation of weighting functions. Implications for the nadir and limb viewing geometries are discussed.

  9. Paramagnetic behavior of Co doped TiO{sub 2} nanocrystals controlled by self-purification mechanism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anitha, B.; Khadar, M. Abdul, E-mail: mabdulkhadar@rediffmail.com; Banerjee, Alok

    Doping in nanocrystals is a challenging process because of the self- purification mechanism which tends to segregate out the dopants resulting in a greater dopant concentration near the surface than at the interior of nanocrystals. In the present work nanocrystals of TiO{sub 2} doped with different atom % of Co were synthesized by peroxide gel method. XRD analysis confirmed the tetragonal anatase structure and HRTEM images showed the rod-like morphology of the samples. Raman modes of anatase phase of TiO{sub 2} along with weak intensity peaks of Co{sub 3}O{sub 4} for higher Co dopant concentrations were observed for the samples.more » EPR measurements revealed the presence of cobalt in +2 oxidation state in the TiO{sub 2} matrix. SQUID measurements indicated paramagnetic behavior of the Co doped TiO{sub 2} nanocrystals. The paramagnetic behavior is attributed to an increased concentration of Co{sup 2+} ions and an increased presence of Co{sub 3}O{sub 4} phase near the surface of the TiO{sub 2} nanocrystals due to self-purification mechanism. - Graphical abstract: Variation of the intensity ratios of XRD peaks as a function of atomic ratio of Co. Inset: variation of structure factor for (101) reflection as a function of atomic ratio of Co. Display Omitted - Highlights: • Co doped TiO{sub 2} nanocrystals were synthesized by peroxide gel method. • HRTEM images showed Co doped TiO{sub 2} nanocrystals to be rod-like. • EPR spectra showed +2 oxidation states for Co in the samples. • Co doped TiO{sub 2} nanocrystals showed paramagnetic behavior.« less

  10. Improved High-Energy Response of AlGaAs/GaAs Solar Cells Using a Low-Cost Technology

    NASA Astrophysics Data System (ADS)

    Noorzad, Camron D.; Zhao, Xin; Harotoonian, Vache; Woodall, Jerry M.

    2016-12-01

    We report on an AlGaAs/GaAs solar cell with a significantly increased high-energy response that was produced via a modified liquid phase epitaxy (LPE) technique. This technique uses a one-step process in which the solid-liquid equilibrium Al-Ga-As:Zn melt in contact with an n-type vendor GaAs substrate simultaneously getters impurities in the substrate that shorten minority carrier lifetimes, diffuses Zn into the substrate to create a p- n junction, and forms a thin p-AlGaAs window layer that enables more high-energy light to be efficiently absorbed. Unlike conventional LPE, this process is performed isothermally. In our "double Al" method, the ratio of Al in the melt ("Al melt ratio") that was used in our process was two times more than what was previously reported in the record 1977 International Business Machines (IBM) solar cell. Photoluminescence (PL) results showed our double Al sample yielded a response to 405 nm light ("blue light"), which was more than twice as intense as the response from our replicated IBM cell. The original 1977 cell had a low-intensity spectral response to photon wavelengths under 443 nm (Woodall and Hovel in Sol Energy Mater Sol Cells 29:176, 1990). Secondary ion mass spectrometry results confirmed the increased blue light response was due to a large reduction in AlGaAs window layer thickness. These results proved increasing the Al melt ratio broadens the spectrum of light that can be transmitted through the window layer into the active GaAs region for absorption, increasing the overall solar cell efficiency. Our enhanced double Al method can pave the way for large-scale manufacturing of low-cost, high-efficiency solar cells.

  11. A simple resonance Rayleigh scattering method for determination of trace CA125 using immuno-AuRu nanoalloy as probe via ultrasonic irradiation

    NASA Astrophysics Data System (ADS)

    Tang, Meiling; Wen, Guiqing; Luo, Yanghe; Liang, Aihui; Jiang, Zhiliang

    2015-01-01

    AuRu nanoalloy (GR) with Au/Ru molar ratio of 32/1 was prepared by the sodium borohydride reduction method. It was used to label the CA125 antibody (Ab) to obtain an immunonanoprobe (GRAb) for cancer antigen 125 (CA125). In pH 7.0 citric acid-Na2HPO4 buffer solution and irradiation of ultrasound, the probes were aggregated nonspecifically to big clusters that showed a strong resonance Rayleigh scattering (RRS) peak at 278 nm. Upon addition of CA125, GRAb reacted specifically with CA125 to form dispersive immunocomplexes of CA125-GRAb in the solution and this process enhanced by the ultrasonic cavitation effect, which led to the RRS intensity decreased greatly. The decreased RRS intensity was linear to the concentration of CA125 in the range of 1.3-80 U/mL, with a detection limit of 0.6 U/mL. The proposed method was applied to detect CA125 in real sample, with satisfactory results.

  12. The effect of exercise mode and intensity of sub-maximal physical activities on salivary testosterone to cortisol ratio and α-amylase in young active males

    PubMed Central

    AZARBAYJANI, MOHAMMAD ALI; FATOLAHI, HOSEYN; RASAEE, MOHAMMAD JAVAD; PEERI, MAGHSOD; BABAEI, ROHOLAH

    2011-01-01

    We examined the effect of exercise intensity and mode on the acute responses of free testosterone to cortisol ratio and salivary α-amylase. We also evaluated the relationship between cortisol and salivary α-amylase. Ten healthy young active males participated voluntarily in this study in six single sessions. They exercised on a cycle ergo meter, treadmill, and elliptical instrument at intensities of 70% and 85% maximum heart rate for 25 minutes. Saliva samples were collected 5 minutes before and 5 minutes after each exercise session. No significant changes were observed for cortisol. Free testosterone to cortisol ratio increased during each exercise session (F5, 45=3.15, P=0.02). However, these changes are only significant after exercise on the treadmill at 70% maximum heart rate (t=2.94, P=0.02) and 85% maximum heart rate (t=0.53, P=0.03). Salivary α-amylase significantly varied among exercise sessions (F5, 45=3.97, P=0.005), and a significant decline was observed after exercise on the elliptical instrument (t=2.38, P=0.04) and treadmill (t=3.55, P=0.006) at 85% maximum heart rate. We found that the free testosterone to cortisol ratio is dependent on the exercise mode, while the salivary α-amylase response is dependent on the intensity of exercise. The increase of free testosterone to cortisol ratio in this study may indicate lower physiological stress in response to performing these exercises. Applying muscular strength with moderate intensity weight-bearing exercises possibly activates the anabolic pathways. Although the cortisol and salivary α-amylase responses were opposite in the majority of the exercise sessions, no significant inverse relationship was observed. PMID:27182369

  13. The effect of exercise mode and intensity of sub-maximal physical activities on salivary testosterone to cortisol ratio and α-amylase in young active males.

    PubMed

    Azarbayjani, Mohammad Ali; Fatolahi, Hoseyn; Rasaee, Mohammad Javad; Peeri, Maghsod; Babaei, Roholah

    We examined the effect of exercise intensity and mode on the acute responses of free testosterone to cortisol ratio and salivary α-amylase. We also evaluated the relationship between cortisol and salivary α-amylase. Ten healthy young active males participated voluntarily in this study in six single sessions. They exercised on a cycle ergo meter, treadmill, and elliptical instrument at intensities of 70% and 85% maximum heart rate for 25 minutes. Saliva samples were collected 5 minutes before and 5 minutes after each exercise session. No significant changes were observed for cortisol. Free testosterone to cortisol ratio increased during each exercise session (F 5, 45 =3.15, P=0.02) . However, these changes are only significant after exercise on the treadmill at 70% maximum heart rate ( t=2.94, P=0.02 ) and 85% maximum heart rate ( t=0.53, P=0.03 ). Salivary α-amylase significantly varied among exercise sessions (F 5, 45 =3.97, P=0.005), and a significant decline was observed after exercise on the elliptical instrument (t=2.38, P=0.04) and treadmill ( t=3.55, P=0.006 ) at 85% maximum heart rate. We found that the free testosterone to cortisol ratio is dependent on the exercise mode, while the salivary α-amylase response is dependent on the intensity of exercise. The increase of free testosterone to cortisol ratio in this study may indicate lower physiological stress in response to performing these exercises. Applying muscular strength with moderate intensity weight-bearing exercises possibly activates the anabolic pathways. Although the cortisol and salivary α-amylase responses were opposite in the majority of the exercise sessions, no significant inverse relationship was observed.

  14. Single-pixel imaging by Hadamard transform and its application for hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Mizutani, Yasuhiro; Shibuya, Kyuki; Taguchi, Hiroki; Iwata, Tetsuo; Takaya, Yasuhiro; Yasui, Takeshi

    2016-10-01

    In this paper, we report on comparisons of single-pixel imagings using Hadamard Transform (HT) and the ghost imaging (GI) in the view point of the visibility under weak light conditions. For comparing the two methods, we have discussed about qualities of images based on experimental results and numerical analysis. To detect images by the TH method, we have illuminated the Hadamard-pattern mask and calculated by orthogonal transform. On the other hand, the GH method can detect images by illuminating random patterns and a correlation measurement. For comparing two methods under weak light intensity, we have controlled illuminated intensities of a DMD projector about 0.1 in signal-to-noise ratio. Though a process speed of the HT image was faster then an image via the GI, the GI method has an advantage of detection under weak light condition. An essential difference between the HT and the GI method is discussed about reconstruction process. Finally, we also show a typical application of the single-pixel imaging such as hyperspectral images by using dual-optical frequency combs. An optical setup consists of two fiber lasers, spatial light modulated for generating patten illumination, and a single pixel detector. We are successful to detect hyperspectrul images in a range from 1545 to 1555 nm at 0.01nm resolution.

  15. Effect of citric acid on material properties of ZnGa2O4:Cr3+ nanopowder prepared by sol-gel method

    NASA Astrophysics Data System (ADS)

    Hussen, Megersa K.; Dejene, Francis B.; Gonfa, Girma G.

    2018-05-01

    This paper reports the material properties of Cr3+ (1.0 mol%)-doped ZnGa2O4 nanopowders prepared by citric acid-assisted sol-gel method with metal cations (Zn + Ga) to citric (M:CA) molar ratios of (1:0.5, 1:1, 1:3 and 1:4). The X-ray diffraction (XRD) results show that the synthesized nanoparticles are cubic structured and concentration of citric acid did not affect the structure. The scanning electron microscope (SEM) shows that the increase of the M:CA molar ratio favors the formation of smaller nano particle of ZnGa2O4:Cr3+. The photoluminescence (PL) is found to be maximum for sample with M:CA ratio of 1:1. Further increase in citric acid leads to significant decrease in the PL intensity. Energy-dispersive X-ray spectroscopy (EDS) measurement confirms the presence of the Zn, Ga, O and Cr ions. Ultraviolet-visible (UV-Vis) spectrophotometer measurement shows an increase in reflectance in visible region and the energy band gap was found to decrease with an increase in citric acid molar ratio. The emission spectra, particle size and photoluminescence lifetimes are comparable with reports on bioimaging applications.

  16. Utility of Cardiovascular Magnetic Resonance-Derived Wave Intensity Analysis As a Marker of Ventricular Function in Children with Heart Failure and Normal Ejection Fraction.

    PubMed

    Ntsinjana, Hopewell N; Chung, Robin; Ciliberti, Paolo; Muthurangu, Vivek; Schievano, Silvia; Marek, Jan; Parker, Kim H; Taylor, Andrew M; Biglino, Giovanni

    2017-01-01

    This study sought to explore the diagnostic insight of cardiovascular magnetic resonance (CMR)-derived wave intensity analysis to better study systolic dysfunction in young patients with chronic diastolic dysfunction and preserved ejection fraction (EF), comparing it against other echocardiographic and CMR parameters. Evaluating systolic and diastolic dysfunctions in children is challenging, and a gold standard method is currently lacking. Patients with presumed diastolic dysfunction [ n  = 18; nine aortic stenosis (AS), five hypertrophic, and four restrictive cardiomyopathies] were compared with age-matched control subjects ( n  = 18). All patients had no mitral or aortic incompetence, significant AS, or reduced systolic EF. E / A ratio, E / E ' ratio, deceleration time, and isovolumetric contraction time were assessed on echocardiography, and indexed left atrial volume (LAVi), acceleration time (AT), ejection time (ET), and wave intensity analyses were calculated from CMR. The latter was performed on CMR phase-contrast flow sequences, defining a ratio of the peaks of the early systolic forward compression wave (FCW) and the end-systolic forward expansion wave (FEW). Significant differences between patients and controls were seen in the E / E ' ratio (8.7 ± 4.0 vs. 5.1 ± 1.3, p  = 0.001) and FCW/FEW ratio (2.5 ± 1.6 vs. 7.2 ± 4.2 × 10 -5 m/s, p  < 0.001), as well as-as expected-LAVi (80.7 ± 22.5 vs. 51.0 ± 10.9 mL/m 2 , p  < 0.001). In particular, patients exhibited a lower FCW (2.5 ± 1.6 vs. 7.2 ± 4.2 × 10 -5 m/s, p  < 0.001) in the face of preserved EF (67 ± 11 vs. 69 ± 5%, p  = 0.392), as well as longer isovolumetric contraction time (49 ± 7 vs. 34 ± 7 ms, p  < 0.001) and ET/AT (0.35 ± 0.04 vs. 0.27 ± 0.04, p  < 0.001). This study shows that the wave intensity-derived ratio summarizing systolic and diastolic function could provide insight into ventricular function in children, on top of CMR and echocardiography, and it was here able to identify an element of ventricular dysfunction with preserved EF in a small group of young patients.

  17. Upconversion properties of Er3+/Yb3+ co-doped TeO2-TiO2-K2O glasses.

    PubMed

    Su, Fangning; Deng, Zaide

    2006-01-01

    The Er3+/Yb3+ co-doped TeO2-TiO2-K2O glasses were prepared by conventional melting procedures, and their upconversion spectra were performed. The dependence of luminescence intensity on the ratio of Yb3+/Er3+ was studied, and the relationship between green upconversion luminescence intensity and Er3+ concentration is discussed in detail. The 546 nm green upconversion luminescence intensity is optimised in the studied glasses either when the Yb3+/Er3+ ratio is 25/1 and Er3+ concentration is 0.1 mol%, or when the Yb3+/Er3+ ratio is 10/1 and Er3+ concentration is 0.15 mol%. These glasses could be one of the potential candidates for LD pumping microchip solid-state lasers.

  18. Extracting survival parameters from isothermal, isobaric, and "iso-concentration" inactivation experiments by the "3 end points method".

    PubMed

    Corradini, M G; Normand, M D; Newcomer, C; Schaffner, D W; Peleg, M

    2009-01-01

    Theoretically, if an organism's resistance can be characterized by 3 survival parameters, they can be found by solving 3 simultaneous equations that relate the final survival ratio to the lethal agent's intensity. (For 2 resistance parameters, 2 equations will suffice.) In practice, the inevitable experimental scatter would distort the results of such a calculation or render the method unworkable. Averaging the results obtained with more than 3 final survival ratio triplet combinations, determined in four or more treatments, can remove this impediment. This can be confirmed by the ability of a kinetic inactivation model derived from the averaged parameters to predict survival patterns under conditions not employed in their determination, as demonstrated with published isothermal survival data of Clostridium botulinum spores, isobaric data of Escherichia coli under HPP, and Pseudomonas exposed to hydrogen peroxide. Both the method and the underlying assumption that the inactivation followed a Weibull-Log logistic (WeLL) kinetics were confirmed in this way, indicating that when an appropriate survival model is available, it is possible to predict the entire inactivation curves from several experimental final survival ratios alone. Where applicable, the method could simplify the experimental procedure and lower the cost of microbial resistance determinations. In principle, the methodology can be extended to deteriorative chemical reactions if they too can be characterized by 2 or 3 kinetic parameters.

  19. Fast decomposition of two ultrasound longitudinal waves in cancellous bone using a phase rotation parameter for bone quality assessment: Simulation study.

    PubMed

    Taki, Hirofumi; Nagatani, Yoshiki; Matsukawa, Mami; Kanai, Hiroshi; Izumi, Shin-Ichi

    2017-10-01

    Ultrasound signals that pass through cancellous bone may be considered to consist of two longitudinal waves, which are called fast and slow waves. Accurate decomposition of these fast and slow waves is considered to be highly beneficial in determination of the characteristics of cancellous bone. In the present study, a fast decomposition method using a wave transfer function with a phase rotation parameter was applied to received signals that have passed through bovine bone specimens with various bone volume to total volume (BV/TV) ratios in a simulation study, where the elastic finite-difference time-domain method is used and the ultrasound wave propagated parallel to the bone axes. The proposed method succeeded to decompose both fast and slow waves accurately; the normalized residual intensity was less than -19.5 dB when the specimen thickness ranged from 4 to 7 mm and the BV/TV value ranged from 0.144 to 0.226. There was a strong relationship between the phase rotation value and the BV/TV value. The ratio of the peak envelope amplitude of the decomposed fast wave to that of the slow wave increased monotonically with increasing BV/TV ratio, indicating the high performance of the proposed method in estimation of the BV/TV value in cancellous bone.

  20. Empowering line intensity mapping to study early galaxies

    NASA Astrophysics Data System (ADS)

    Comaschi, P.; Ferrara, A.

    2016-12-01

    Line intensity mapping is a superb tool to study the collective radiation from early galaxies. However, the method is hampered by the presence of strong foregrounds, mostly produced by low-redshift interloping lines. We present here a general method to overcome this problem which is robust against foreground residual noise and based on the cross-correlation function ψαL(r) between diffuse line emission and Lyα emitters (LAE). We compute the diffuse line (Lyα is used as an example) emission from galaxies in a (800 Mpc)3 box at z = 5.7 and 6.6. We divide the box in slices and populate them with 14 000(5500) LAEs at z = 5.7(6.6), considering duty cycles from 10-3 to 1. Both the LAE number density and slice volume are consistent with the expected outcome of the Subaru Hyper Suprime Cam survey. We add Gaussian random noise with variance σN up to 100 times the variance of the Lyα emission, σα, to simulate residual foregrounds and compute ψαL(r). We find that the signal-to-noise ratio of the observed ψαL(r) does not change significantly if σN ≤ 10σα and show that in these conditions the mean line intensity, ILyα, can be precisely recovered independently of the LAE duty cycle. Even if σN = 100σα, Iα can be constrained within a factor 2. The method works equally well for any other line (e.g. [C II], He II) used for the intensity-mapping experiment.

  1. Contribution of proton leak to oxygen consumption in skeletal muscle during intense exercise is very low despite large contribution at rest

    PubMed Central

    2017-01-01

    A computer model was used to simulate the dependence of protonmotive force (Δp), proton leak and phenomenological (involving proton leak) ATP/O2 ratio on work intensity in skeletal muscle. Δp, NADH and proton leak decreased with work intensity. The contribution of proton leak to oxygen consumption (V˙O2) decreased from about 60% at rest to about 3 and 1% at moderate and heavy/severe exercise, respectively, while the ATP/O2 ratio increased from 2.1 to 5.5 and 5.7. A two-fold increase in proton leak activity or its decrease to zero decreased/increased the ATP/O2 ratio by only about 3 and 1% during moderate and heavy/severe exercise, respectively. The low contribution of proton leak to V˙O2 in intensively working skeletal muscle was mostly caused by a huge increase in ATP usage intensity during rest-to-work transition, while OXPHOS, and thus oxidative ATP supply and V˙O2 related to it, was mostly stimulated by high each-step activation (ESA) of OXPHOS complexes. The contribution of proton leak to V˙O2 and ATP/O2 ratio in isolated mitochondria should not be directly extrapolated to working muscle, as mitochondria lack ESA, at least in the absence of Ca2+, and therefore V˙O2 cannot be elevated as much as in intact muscle. PMID:29045413

  2. Contribution of proton leak to oxygen consumption in skeletal muscle during intense exercise is very low despite large contribution at rest.

    PubMed

    Korzeniewski, Bernard

    2017-01-01

    A computer model was used to simulate the dependence of protonmotive force (Δp), proton leak and phenomenological (involving proton leak) ATP/O2 ratio on work intensity in skeletal muscle. Δp, NADH and proton leak decreased with work intensity. The contribution of proton leak to oxygen consumption ([Formula: see text]) decreased from about 60% at rest to about 3 and 1% at moderate and heavy/severe exercise, respectively, while the ATP/O2 ratio increased from 2.1 to 5.5 and 5.7. A two-fold increase in proton leak activity or its decrease to zero decreased/increased the ATP/O2 ratio by only about 3 and 1% during moderate and heavy/severe exercise, respectively. The low contribution of proton leak to [Formula: see text] in intensively working skeletal muscle was mostly caused by a huge increase in ATP usage intensity during rest-to-work transition, while OXPHOS, and thus oxidative ATP supply and [Formula: see text] related to it, was mostly stimulated by high each-step activation (ESA) of OXPHOS complexes. The contribution of proton leak to [Formula: see text] and ATP/O2 ratio in isolated mitochondria should not be directly extrapolated to working muscle, as mitochondria lack ESA, at least in the absence of Ca2+, and therefore [Formula: see text] cannot be elevated as much as in intact muscle.

  3. Heart rate variability in children with tricyclic antidepressant intoxication.

    PubMed

    Dinleyici, Ener Cagri; Kilic, Zubeyir; Sahin, Sabiha; Tutuncu-Toker, Rabia; Eren, Makbule; Yargic, Zeynel Abidin; Kosger, Pelin; Ucar, Birsen

    2013-01-01

    The aim of this study was to evaluate HRV in children requiring intensive care unit stays due to TCA poisoning between March 2009 and July 2010. In the time-domain nonspectral evaluation, the SDNN (P < 0.001), SDNNi (P < 0.05), RMSDD (P < 0.01), and pNN50 (P < 0.01) were found to be significantly lower in the TCA intoxication group. The spectral analysis of the data recorded during the first 5 minutes after intensive care unit admission showed that the values of the nLF (P < 0.05) and the LF/HF ratio (P = 0.001) were significantly higher in the TCA intoxication group, while the nHF (P = 0.001) values were significantly lower. The frequency-domain spectral analysis of the data recorded during the last 5 minutes showed a lower nHF (P = 0.001) in the TCA intoxication group than in the controls, and the LF/HF ratio was significantly higher (P < 0.05) in the intoxication group. The LF/HF ratio was higher in the seven children with seizures (P < 0.001). These findings provided us with a starting point for the value of HRV analysis in determining the risk of arrhythmia and convulsion in TCA poisoning patients. HRV can be used as a noninvasive testing method in determining the treatment and prognosis of TCA poisoning patients.

  4. Influence of Smoking Consumption and Nicotine Dependence Degree in Cardiac Autonomic Modulation

    PubMed Central

    dos Santos, Ana Paula Soares; Ramos, Dionei; de Oliveira, Gabriela Martins; dos Santos, Ana Alice Soares; Freire, Ana Paula Coelho Figueira; It, Juliana Tiyaki; Fernandes, Renato Peretti Prieto; Vanderlei, Luiz Carlos Marques; Ramos, Ercy Mara Cipulo

    2016-01-01

    Background Smoking consumption alters cardiac autonomic function. Objective Assess the influence of the intensity of smoking and the nicotine dependence degree in cardiac autonomic modulation evaluated through index of heart rate variability (HRV). Methods 83 smokers, of both genders, between 50 and 70 years of age and with normal lung function were divided according to the intensity of smoking consumption (moderate and severe) and the nicotine dependency degree (mild, moderate and severe). The indexes of HRV were analyzed in rest condition, in linear methods in the time domain (TD), the frequency domain (FD) and through the Poincaré plot. For the comparison of smoking consumption, unpaired t test or Mann-Whitney was employed. For the analysis between the nicotine dependency degrees, we used the One-way ANOVA test, followed by Tukey's post test or Kruskal-Wallis followed by Dunn's test. The significance level was p < 0,05. Results Differences were only found when compared to the different intensities of smoking consumption in the indexes in the FD. LFun (62.89 ± 15.24 vs 75.45 ± 10.28), which corresponds to low frequency spectrum component in normalized units; HFun (37.11 ± 15.24 vs 24.55 ± 10.28), which corresponds to high frequency spectrum component in normalized units and in the LF/HF ratio (2.21 ± 1.47 vs 4.07 ± 2.94). However, in the evaluation of nicotine dependency, significant differences were not observed (p > 0.05). Conclusion Only the intensity of smoking consumption had an influence over the cardiac autonomic modulation of the assessed tobacco smokers. Tobacco smokers with severe intensity of smoking consumption presented a lower autonomic modulation than those with moderate intensity. PMID:27142649

  5. Differentiation of sCJD and vCJD forms by automated analysis of basal ganglia intensity distribution in multisequence MRI of the brain--definition and evaluation of new MRI-based ratios.

    PubMed

    Linguraru, Marius George; Ayache, Nicholas; Bardinet, Eric; Ballester, Miguel Angel González; Galanaud, Damien; Haïk, Stéphane; Faucheux, Baptiste; Hauw, Jean-Jacques; Cozzone, Patrick; Dormont, Didier; Brandel, Jean-Philippe

    2006-08-01

    We present a method for the analysis of basal ganglia (including the thalamus) for accurate detection of human spongiform encephalopathy in multisequence magnetic resonance imaging (MRI) of the brain. One common feature of most forms of prion protein diseases is the appearance of hyperintensities in the deep grey matter area of the brain in T2-weighted magnetic resonance (MR) images. We employ T1, T2, and Flair-T2 MR sequences for the detection of intensity deviations in the internal nuclei. First, the MR data are registered to a probabilistic atlas and normalized in intensity. Then smoothing is applied with edge enhancement. The segmentation of hyperintensities is performed using a model of the human visual system. For more accurate results, a priori anatomical data from a segmented atlas are employed to refine the registration and remove false positives. The results are robust over the patient data and in accordance with the clinical ground truth. Our method further allows the quantification of intensity distributions in basal ganglia. The caudate nuclei are highlighted as main areas of diagnosis of sporadic Creutzfeldt-Jakob Disease (sCJD), in agreement with the histological data. The algorithm permitted the classification of the intensities of abnormal signals in sCJD patient FLAIR images with a higher hypersignal in caudate nuclei (10/10) and putamen (6/10) than in thalami. Defining normalized MRI measures of the intensity relations between the internal grey nuclei of patients, we robustly differentiate sCJD and variant CJD (vCJD) patients, in an attempt to create an automatic classification tool of human spongiform encephalopathies.

  6. Factors Associated with Fatality during the Intensive Phase of Anti-Tuberculosis Treatment

    PubMed Central

    Casals, M.; Caminero, J. A.; García-García, J. M.; Jiménez-Fuentes, M. A.; Medina, J. F.; Millet, J. P.; Ruiz-Manzano, J.; Caylá, J.

    2016-01-01

    Objective To determine the case-fatality rate (CFR) at the end of the intensive phase of tuberculosis (TB) treatment, and factors associated with fatality. Methods TB patients diagnosed between 2006 and 2013 were followed-up during treatment. We computed the CFR at the end of the intensive phase of TB treatment, and the incidence of death per 100 person-days (pd) of follow-up. We performed survival analysis using the Kaplan-Meier method and Cox regression, and calculate hazard ratios (HR) and 95% confidence intervals (CI). Results A total of 5,182 patients were included, of whom 180 (3.5%) died; 87 of these deaths (48.3%) occurred during the intensive phase of treatment, with a CFR of 1.7%. The incidence of death was 0.028/100 pd. The following factors were associated with death during the intensive phase: being >50 years (HR = 36.9;CI:4.8–283.4); being retired (HR = 2.4;CI:1.1–5.1); having visited the emergency department (HR = 3.1;CI:1.2–7.7); HIV infection (HR = 3.4;CI:1.6–7.2); initial standard treatment with 3 drugs (HR = 2.0;CI:1.2–3.3) or non-standard treatments (HR = 2.68;CI:1.36–5.25); comprehension difficulties (HR = 2.8;CI:1.3–6.1); and smear-positive sputum (HR = 2.3-CI:1.0–4.8). Conclusion There is a non-negligible CFR during the intensive phase of TB, whose reduction should be prioritised. The CFR could be a useful indicator for evaluating TB programs. PMID:27487189

  7. Chemical Environment Effects on K[beta]/K[alpha] Intensity Ratio: An X-Ray Fluorescence Experiment on Periodic Trends

    ERIC Educational Resources Information Center

    Durham, Chaney R.; Chase, Jeffery M.; Nivens, Delana A.; Baird, William H.; Padgett, Clifford W.

    2011-01-01

    X-ray fluorescence (XRF) data from an energy-dispersive XRF instrument were used to investigate the chlorine K[alpha] and K[beta] peaks in several group 1 salts. The ratio of the peak intensity is sensitive to the local chemical environment of the chlorine atoms studied in this experiment and it shows a periodic trend for these salts. (Contains 1…

  8. Fe II fluorescence and anomalous C IV doublet intensities in symbiotic novae

    NASA Technical Reports Server (NTRS)

    Michalitsianos, A. G.; Kafatos, M.; Meier, S. R.

    1992-01-01

    The variation of absolute intensities of Bowen-excited Fe II emission in the symbiotic stars RR Tel, RX Pup, and AG Peg is examined. The C IV doublet intensity ratios in RR Tel were not anomalous between 1979 and 1989, and the ratio had typical values within the optically thin range. The intensity of individual Fe II Bowen-excited lines is correlated with the C IV 1548.2 A flux, suggesting the presence of a foreground Fe II region in which fluorescent-excited material responds to flux variations of C IV 1548.2 A. In RX Pup the combined fluxes of Fe II Bowen-pumped lines can account for an appreciable fraction of the flux deficit in the C IV 1548.2 A line when the C IV doublet ratio is less than the optically thick limit of unity. The Fe II Bowen lines in RX Pup exhibit a velocity range from 0 to 80 km/s, where several strong Fe II emission lines correspond to deep absorption structure in the C IV 1548.2 A line profile. In AG Peg and C IV 1548.2 A flux deficit cannot be explained by Fe II fluorescent absorption alone when the C IV doublet ratio anomaly is at an extreme.

  9. Detection ratios on winter surveys of Rocky Mountain Trumpeter Swans Cygnus buccinator

    USGS Publications Warehouse

    Bart, J.; Mitchell, C.D.; Fisher, M.N.; Dubovsky, J.A.

    2007-01-01

    We estimated the detection ratio for Rocky Mountain Trumpeter Swans Cygnus buccinator that were counted during aerial surveys made in winter. The standard survey involved counting white or grey birds on snow and ice and thus might be expected to have had low detection ratios. On the other hand, observers were permitted to circle areas where the birds were concentrated multiple times to obtain accurate counts. Actual numbers present were estimated by conducting additional intensive aerial counts either immediately before or immediately after the standard count. Surveyors continued the intensive surveys at each area until consecutive counts were identical. The surveys were made at 10 locations in 2006 and at 19 locations in 2007. A total of 2,452 swans were counted on the intensive surveys. Detection ratios did not vary detectably with year, observer, which survey was conducted first, age of the swans, or the number of swans present. The overall detection ratio was 0.93 (90% confidence interval 0.82-1.04), indicating that the counts were quite accurate. Results are used to depict changes in population size for Rocky Mountain Trumpeter Swans from 1974-2007. ?? Wildfowl & Wetlands Trust.

  10. Effects of Mg/Ga and V/III source ratios on hole concentration of N-polar (000\\bar{1}) p-type GaN grown by metalorganic vapor phase epitaxy

    NASA Astrophysics Data System (ADS)

    Nonoda, Ryohei; Shojiki, Kanako; Tanikawa, Tomoyuki; Kuboya, Shigeyuki; Katayama, Ryuji; Matsuoka, Takashi

    2016-05-01

    The effects of growth conditions such as Mg/Ga and V/III ratios on the properties of N-polar (000\\bar{1}) p-type GaN grown by metalorganic vapor phase epitaxy were studied. Photoluminescence spectra from Mg-doped GaN depended on Mg/Ga and V/III ratios. For the lightly doped samples, the band-to-acceptor emission was observed at 3.3 eV and its relative intensity decreased with increasing V/III ratio. For the heavily doped samples, the donor-acceptor pair emission was observed at 2.8 eV and its peak intensity monotonically decreased with V/III ratio. The hole concentration was maximum for the Mg/Ga ratio. This is the same tendency as in group-III polar (0001) growth. The V/III ratio also reduced the hole concentration. The higher V/III ratio reduced the concentration of residual donors such as oxygen by substituting nitrogen atoms. The surface became rougher with increasing V/III ratio and the hillock density increased.

  11. Prenatal diagnosis of fetal respiratory function: evaluation of fetal lung maturity using lung-to-liver signal intensity ratio at magnetic resonance imaging.

    PubMed

    Oka, Yasuko; Rahman, Mosfequr; Sasakura, Chihaya; Waseda, Tomoo; Watanabe, Yukio; Fujii, Ryota; Makinoda, Satoru

    2014-12-01

    The purpose of this retrospective study is to determine the fetal lung-to-liver signal intensity ratio (LLSIR) on T2-weighted images for the prediction of neonatal respiratory outcome. One hundred ten fetuses who underwent magnetic resonance imaging (MRI) examination for various indications after 22 weeks of gestation participated in this study. LLSIR was measured as the ratio of signal intensities of the fetal lung and liver on T2-weighted images at MRI. We examined the changes of the ratio with advancing gestation and the relations between LLSIR and the presence of the severe respiratory disorder (SRD) after birth. The best cut-off value of the LLSIR to predict respiratory outcome after birth was calculated using receiver operating characteristic (ROC) curve analysis. Lung-to-liver signal intensity ratio correlated significantly with advancing gestational age (R = 0.35, p < 0.001). The non-SRD group had higher LLSIR compared with the SRD group (2.15 ± 0.30 vs. 1.53 ± 0.40, p < 0.001). ROC curve analysis showed that fetuses with an LLSIR < 2.00 were more likely to develop SRD [sensitivity: 100%, 95% confidence interval (CI): 52-100%; specificity: 73%, 95% CI 54-88%]. The fetal LLSIR on T2-weighted images is an accurate marker to diagnose the fetal lung maturity. © 2014 The Authors. Prenatal Diagnosis published by John Wiley & Sons, Ltd.

  12. Aspect ratio dependence of the enhancement of fluorescence intensity by gold nanobipyramids for cancer cell imaging and photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Wang, Shimiao; Mi, Lan; Liu, Jun

    2018-07-01

    Enhancement of dye fluorescence intensity was studied by modifying the aspect ratio of gold nanobipyramids (AuBPs) from 3.2 to 6.6. The emission fluorescence intensity of sulfonated aluminum phthalocyanine (AlPcS) was strongly dependent on the aspect ratio of AuBPs. Furthermore, we found that the energy transfer from excited AlPcS to AuBPs was a key determinant of the efficacy of metal-enhanced fluorescence. By means of AuBPs with a higher aspect ratio, such that the surface plasmon resonance band does not overlap with the energy level of excited AlPcS, metal-enhanced fluorescence of various AlPcS–AuBP conjugates was determined, and the maximal enhancement factor was found to be 14. The enhanced fluorescence intensity of AlPcS conjugated with AuBPs indicates promising plasmonic properties. An apoptosis assay of HeLa cells revealed that AlPcS–AuBPs, when used as a drug, can enhance the effectiveness of photodynamic therapy (PDT). Furthermore, AuBPs with the longitudinal absorption peak wavelength of 1050 nm had optimal proapoptotic effects. HeLa cells treated with AlPcS–AuBPs (ratio 0.42 µM to 0.01 nM) had viability as low as 29.31% after 32 J cm‑2 ultraviolet light exposure, indicating the strong potential of AlPcS–AuBPs to improve the efficacy of PDT.

  13. Three-dimensional motion detection of a 20-nm gold nanoparticle using twilight-field digital holography with coherence regulation.

    PubMed

    Goto, Kazufumi; Hayasaki, Yoshio

    2015-07-15

    In the twilight-field method for obtaining interference fringes with high contrast in in-line digital holography, only the intensity of the reference light is regulated to be close to the intensity of the object light, which is the ultra-weak scattered light from a nanoparticle, by using a low-frequency attenuation filter. Coherence of the light also strongly affects the contrast of the interference fringes. High coherence causes a lot of undesired coherent noise, which masks the fringes derived from the nanoparticles. Too-low coherence results in fringes with low contrast and a correspondingly low signal-to-noise ratio. Consequently, proper regulation of the coherence of the light source, in this study the spectral width, improves the minimum detectable size in holographic three-dimensional position measurement of nanoparticles. By using these methods, we were able to measure the position of a gold nanoparticle with a minimum diameter of 20 nm.

  14. Novel method for detecting weak magnetic fields at low frequencies

    NASA Astrophysics Data System (ADS)

    González-Martínez, S.; Castillo-Torres, J.; Mendoza-Santos, J. C.; Zamorano-Ulloa, R.

    2005-06-01

    A low-level-intensity magnetic field detection system has been designed and developed based on the amplification-selection process of signals. This configuration is also very sensitive to magnetic field changes produced by harmonic-like electrical currents transported in finite-length wires. Experimental and theoretical results of magnetic fields detection as low as 10-9T at 120Hz are also presented with an accuracy of around 13%. The assembled equipment is designed to measure an electromotive force induced in a free-magnetic-core coil in order to recover signals which are previously selected, despite the fact that their intensities are much lower than the environment electromagnetic radiation. The prototype has a signal-to-noise ratio of 60dB. This system also presents the advantage for using it as a portable unit of measurement. The concept and prototype may be applied, for example, as a nondestructive method to analyze any corrosion formation in metallic oil pipelines which are subjected to cathodic protection.

  15. The qualitative f-ratio method applied to electron channelling-induced x-ray imaging with an annular silicon drift detector in a scanning electron microscope in the transmission mode.

    PubMed

    Brodusch, Nicolas; Gauvin, Raynald

    2017-09-01

    Electron channelling is known to affect the x-ray production when an accelerated electron beam is applied to a crystalline material and is highly dependent on the local crystal orientation. This effect, unless very long counting time are used, is barely noticeable on x-ray energy spectra recorded with conventional silicon drift detectors (SDD) located at a small elevation angle. However, the very high count rates provided by the new commercially available annular SDDs permit now to observe this effect routinely and may, in some circumstances, hide the true elemental x-ray variations due to the local true specimen composition. To circumvent this issue, the recently developed f-ratio method was applied to display qualitatively the true net intensity x-ray variations in a thin specimen of a Ti-6Al-4V alloy in a scanning electron microscope in transmission mode. The diffraction contrast observed in the x-ray images was successfully cancelled through the use of f-ratios and the true composition variations at the grain boundaries could be observed in relation to the dislocation alignment prior to the β-phase nucleation. The qualitative effectiveness in removing channelling effects demonstrated in this work makes the f-ratio, in its quantitative form, a possible alternative to the ZAF method in channelling conditions. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  16. EMPIRICAL DETERMINATION OF EINSTEIN A-COEFFICIENT RATIOS OF BRIGHT [Fe II] LINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giannini, T.; Antoniucci, S.; Nisini, B.

    The Einstein spontaneous rates (A-coefficients) of Fe{sup +} lines have been computed by several authors with results that differ from each other by up to 40%. Consequently, models for line emissivities suffer from uncertainties that in turn affect the determination of the physical conditions at the base of line excitation. We provide an empirical determination of the A-coefficient ratios of bright [Fe II] lines that would represent both a valid benchmark for theoretical computations and a reference for the physical interpretation of the observed lines. With the ESO-Very Large Telescope X-shooter instrument between 3000 Å and 24700 Å, we obtainedmore » a spectrum of the bright Herbig-Haro object HH 1. We detect around 100 [Fe II] lines, some of which with a signal-to-noise ratios ≥100. Among these latter lines, we selected those emitted by the same level, whose dereddened intensity ratios are direct functions of the Einstein A-coefficient ratios. From the same X-shooter spectrum, we got an accurate estimate of the extinction toward HH 1 through intensity ratios of atomic species, H I  recombination lines and H{sub 2} ro-vibrational transitions. We provide seven reliable A-coefficient ratios between bright [Fe II] lines, which are compared with the literature determinations. In particular, the A-coefficient ratios involving the brightest near-infrared lines (λ12570/λ16440 and λ13209/λ16440) are in better agreement with the predictions by the Quinet et al. relativistic Hartree-Fock model. However, none of the theoretical models predict A-coefficient ratios in agreement with all of our determinations. We also show that literature data of near-infrared intensity ratios better agree with our determinations than with theoretical expectations.« less

  17. Fuzzy classifier based support vector regression framework for Poisson ratio determination

    NASA Astrophysics Data System (ADS)

    Asoodeh, Mojtaba; Bagheripour, Parisa

    2013-09-01

    Poisson ratio is considered as one of the most important rock mechanical properties of hydrocarbon reservoirs. Determination of this parameter through laboratory measurement is time, cost, and labor intensive. Furthermore, laboratory measurements do not provide continuous data along the reservoir intervals. Hence, a fast, accurate, and inexpensive way of determining Poisson ratio which produces continuous data over the whole reservoir interval is desirable. For this purpose, support vector regression (SVR) method based on statistical learning theory (SLT) was employed as a supervised learning algorithm to estimate Poisson ratio from conventional well log data. SVR is capable of accurately extracting the implicit knowledge contained in conventional well logs and converting the gained knowledge into Poisson ratio data. Structural risk minimization (SRM) principle which is embedded in the SVR structure in addition to empirical risk minimization (EMR) principle provides a robust model for finding quantitative formulation between conventional well log data and Poisson ratio. Although satisfying results were obtained from an individual SVR model, it had flaws of overestimation in low Poisson ratios and underestimation in high Poisson ratios. These errors were eliminated through implementation of fuzzy classifier based SVR (FCBSVR). The FCBSVR significantly improved accuracy of the final prediction. This strategy was successfully applied to data from carbonate reservoir rocks of an Iranian Oil Field. Results indicated that SVR predicted Poisson ratio values are in good agreement with measured values.

  18. The anomalous C 4 intensity ratio in symbiotic stars

    NASA Technical Reports Server (NTRS)

    Michalitsianos, A. G.; Kafatos, M.; Fahey, R. P.

    1988-01-01

    The C IV lambda lambda 1548.2,1550.8 resonance doublet in a symbiotic stars was shown to exhibit anomalous line intensity ratios in which I (lambda 1548.2)/I(lambda 1550.8) less than 1, or less than the optically-thick limit of unity. The R Aquarii-central HII region and RX Puppis exhibit this phenomena. The I(lambda 1548.2)/I(lambda 1550.8) ratio in RX Puppis is found to vary inversely with the total C IV line intensity, and with the FES-visual light, as the object declined over a 5 yr period following a brightening in UV and optical emission which peaked in 1982. This doublet intensity behavior could be explained by a wind which has a narrow velocity range of 600 approx. less than sup v wind approx. less than 1000 km/sec, or by the pumping of the Fe II (mul. 45.01) transition a sup 4 F sub 9/2 - y sup 4 H(o) sub 11/2 by C IV lambda 1548.2, which effectively scatters C IV photons into the Fe II spectrum in these objects.

  19. Optical assessment of bone bioimplants

    NASA Astrophysics Data System (ADS)

    Timchenko, P. E.; Timchenko, E. V.; Volova, L. T.; Dolgushkin, D. A.; Boltovskaya, V. V.; Frolov, O. O.; Fedorova, Ya. V.

    2017-08-01

    The results of application of the Raman spectroscopy method for the estimation of alternative sources for the production of bone spongy implants using the "Lioplast" technology, namely, the femoral heads resected in the operation of hip replacement surgery, are presented. It is shown that Raman spectroscopy can be used to estimate the component composition of the surface of bone implants during their processing. Comparing different sources of sponge bone production, no significant differences were found, but there are differences in the ratio of the intensities of the Raman peaks at wave numbers 1555 cm-1 and 1665 cm-1 corresponding to amide II and amide I, and also in the intensity of Raman peaks at wave numbers of 959 cm-1 (PO4 3- (ν1)) and 1068 cm-1 (CO3 2- (ν1) B-type substitution).

  20. Nonlinear plasmonic behavior of nanohole arrays in thin gold films for imaging lipids

    NASA Astrophysics Data System (ADS)

    Subramaniyam, Nagarajan; Shah, Ali; Dreser, Christoph; Isomäki, Antti; Fleischer, Monika; Sopanen, Markku

    2018-06-01

    We demonstrate linear and nonlinear plasmonic behaviors of periodic nanohole arrays in thin gold (Au) films with varying periodicities. As expected, the linear optical transmission spectra of the nanohole arrays show a red-shift of the resonance wavelength and Wood's anomaly with increasing hole spacing. The optical transmission and electric near-field intensity distribution of the nanohole arrays are simulated using the finite element method. The nonlinear plasmonic behavior of the nanohole arrays is studied by using picosecond pulsed excitation at near-infrared wavelengths. The characteristic nonlinear signals indicating two-photon excited luminescence (TPEL), sum frequency generation, second harmonic generation, and four-wave mixing (FWM) are observed. A maximum FWM/TPEL signal intensity ratio is achieved for nanohole arrays with a periodicity of 500 nm. Furthermore, the significant FWM signal intensity and contrast compared to the background were harnessed to demonstrate the ability of surface-enhanced coherent anti-Stokes Raman scattering to visualize low concentrations of lipids deposited on the nanohole array with a periodicity of 500 nm.

  1. Synthesis of novel branched β-NaLuF4: Yb/Er upconversion luminescence material and investigation of its optical properties

    NASA Astrophysics Data System (ADS)

    Ding, Yanli; Yang, Tonghui; Yin, Naiqiang; Shu, Fangjie; Zhao, Ying; Zhang, Xiaodan

    2018-05-01

    Branched β-NaLuF4: Yb/Er was synthesized using a simple hydrothermal method by controlling the NaF/Ln molar ratio. In contrast to the β-NaYF4: Yb/Er hexagonal disks, the branched β-NaLuF4: Yb/Er has stronger emission intensity. The integrated intensities of green and red emission bands were as 6.2 and 3.3 times as that of NaYF4, respectively. The branched β-NaLuF4: Yb/Er has the smaller unit cell volume, the higher absorption intensity around 980 nm and the lower crystal field symmetry than NaYF4, which made a significant contribution to the stronger upconversion (UC) fluorescence emissions. The results indicate that the branched β-NaLuF4: Yb/Er is an excellent UC luminescence material. The current research has a great potential in improving near-infrared conversion efficiency of solar cells.

  2. The Effect of the Laboratory Specimen on Fatigue Crack Growth Rate

    NASA Technical Reports Server (NTRS)

    Forth, S. C.; Johnston, W. M.; Seshadri, B. R.

    2006-01-01

    Over the past thirty years, laboratory experiments have been devised to develop fatigue crack growth rate data that is representative of the material response. The crack growth rate data generated in the laboratory is then used to predict the safe operating envelope of a structure. The ability to interrelate laboratory data and structural response is called similitude. In essence, a nondimensional term, called the stress intensity factor, was developed that includes the applied stresses, crack size and geometric configuration. The stress intensity factor is then directly related to the rate at which cracks propagate in a material, resulting in the material property of fatigue crack growth response. Standardized specimen configurations and experimental procedures have been developed for laboratory testing to generate crack growth rate data that supports similitude of the stress intensity factor solution. In this paper, the authors present laboratory fatigue crack growth rate test data and finite element analyses that show similitude between standard specimen configurations tested using the constant stress ratio test method is unobtainable.

  3. Noiseless intensity amplification of repetitive signals by coherent addition using the temporal Talbot effect

    PubMed Central

    Maram, Reza; Van Howe, James; Li, Ming; Azaña, José

    2014-01-01

    Amplification of signal intensity is essential for initiating physical processes, diagnostics, sensing, communications and measurement. During traditional amplification, the signal is amplified by multiplying the signal carriers through an active gain process, requiring the use of an external power source. In addition, the signal is degraded by noise and distortions that typically accompany active gain processes. We show noiseless intensity amplification of repetitive optical pulse waveforms with gain from 2 to ~20 without using active gain. The proposed method uses a dispersion-induced temporal self-imaging (Talbot) effect to redistribute and coherently accumulate energy of the original repetitive waveforms into fewer replica waveforms. In addition, we show how our passive amplifier performs a real-time average of the wave-train to reduce its original noise fluctuation, as well as enhances the extinction ratio of pulses to stand above the noise floor. Our technique is applicable to repetitive waveforms in any spectral region or wave system. PMID:25319207

  4. Laplace-SGBEM analysis of the dynamic stress intensity factors and the dynamic T-stress for the interaction between a crack and auxetic inclusions

    NASA Astrophysics Data System (ADS)

    Kwon, Kibum

    A dynamic analysis of the interaction between a crack and an auxetic (negative Poisson ratio)/non-auxetic inclusion is presented. The two most important fracture parameters, namely the stress intensity factors and the T-stress are analyzed by using the symmetric Galerkin boundary element method in the Laplace domain for three different models of crack-inclusion interaction. To investigate the effects of auxetic inclusions on the fracture behavior of composites reinforced by this new type of material, comparisons of the dynamic stress intensity factors and the dynamic T-stress are made between the use of auxetic inclusions as opposed to the use of traditional inclusions. Furthermore, the technique presented in this research can be employed to analyze for the interaction between a crack and a cluster of auxetic/non-auxetic inclusions. Results from the latter models can be employed in crack growth analysis in auxetic-fiber-reinforced composites.

  5. The Application of Quality Identification in Honey by Photoacoustic Spectroscopy.

    PubMed

    Tao, Wen-ting; Yuan, Ping; Guo, Wen-juan; Liu, Jian-en

    2015-05-01

    The photoacoustic spectrum of glucose, sucrose and honey solutions in the visible range are measured by using the single-light photoacoustic spectrometer, and are compared with the spectra from spedtrophotometry method. The spectral characteristics of the above solutions show that the spectral background intensity and spectral profile have some differences for different kinds of solutions. The spectra of the three kinds of solutions all have strong peak value at 485 and 655 nm, but the intensity ratios between the two peaks are different. Besides, there are characteristic peak at 475, 576 and 630 nm for glucose, and the sucrose has apparent characteristic peak at 632 nm, these characteristic peaks can be used for detecting whether the natural honey has been added glucose or sucrose. By comparing two kinds of spectrum of the same solution, the intensity of photoacoustic spectrum is more responsive to the wavelength, indicating photoacoustic spectrometry has a higher sensitivity in the test of material composition.

  6. Numerical investigation of the influence of elevated turbulence levels on the cooling effectiveness of an anti-vortex hole geometry

    NASA Astrophysics Data System (ADS)

    Repko, Timothy William

    A novel film cooling hole geometry for use in gas turbine engines has been investigated numerically by solving the Reynolds Averaged Navier-Stokes equations in a commercial CFD code (STAR-CCM+) with varying turbulence intensity and length scale using the k-o SST turbulence model. Both steady and unsteady results were considered in order to investigate the effects of freestream turbulence intensity and length scale on this novel anti-vortex hole (AVH) concept. The AVH geometry utilizes two side holes, one on each side of the main hole, to attempt to mitigate the vorticity from the jet from the main hole. The AVH concept has been shown by past research to provide a substantial improvement over conventional film cooling hole designs. Past research has been limited to low turbulence intensity and small length scales that are not representative of the turbulent flow exiting the combustor. Three turbulence intensities (Tu = 5, 10 and 20%) and three length scales normalized by the main cooling hole diameter (Λ x/dm = 1, 3, 6) were considered in this study for a total of nine turbulence conditions. The highest intensity, largest length scale turbulence case (Tu = 20, Λx/dm = 6) is considered most representative of engine conditions and was shown to have the best cooling performance. Results show that the turbulence in the hot gases exiting the combustor can aid in the film cooling for the AVH geometry at high blowing ratios (BR = 2.0), where the blowing ratio is essentially the ratio of the jet-to-mainstream mass flux ratios. Length scale was shown to have an insignificant effect on the cooling performance at low turbulence intensity and a moderate effect at higher turbulence intensities. The adiabatic film cooling effectiveness was shown to increase as the turbulence intensity was elevated. The convective heat transfer coefficient was also shown to increase at the turbulence intensity was elevated. An increase in the heat transfer coefficient is a deleterious effect and must be weighed against the improvements in the adiabatic cooling effectiveness. The net heat flux reduction (NHFR) is the parameter used to quantify the net benefit of film cooling. As a general trend, the NHFR was shown to increase with the turbulence intensity in all cases.

  7. Accurate determination of the charge transfer efficiency of photoanodes for solar water splitting.

    PubMed

    Klotz, Dino; Grave, Daniel A; Rothschild, Avner

    2017-08-09

    The oxygen evolution reaction (OER) at the surface of semiconductor photoanodes is critical for photoelectrochemical water splitting. This reaction involves photo-generated holes that oxidize water via charge transfer at the photoanode/electrolyte interface. However, a certain fraction of the holes that reach the surface recombine with electrons from the conduction band, giving rise to the surface recombination loss. The charge transfer efficiency, η t , defined as the ratio between the flux of holes that contribute to the water oxidation reaction and the total flux of holes that reach the surface, is an important parameter that helps to distinguish between bulk and surface recombination losses. However, accurate determination of η t by conventional voltammetry measurements is complicated because only the total current is measured and it is difficult to discern between different contributions to the current. Chopped light measurement (CLM) and hole scavenger measurement (HSM) techniques are widely employed to determine η t , but they often lead to errors resulting from instrumental as well as fundamental limitations. Intensity modulated photocurrent spectroscopy (IMPS) is better suited for accurate determination of η t because it provides direct information on both the total photocurrent and the surface recombination current. However, careful analysis of IMPS measurements at different light intensities is required to account for nonlinear effects. This work compares the η t values obtained by these methods using heteroepitaxial thin-film hematite photoanodes as a case study. We show that a wide spread of η t values is obtained by different analysis methods, and even within the same method different values may be obtained depending on instrumental and experimental conditions such as the light source and light intensity. Statistical analysis of the results obtained for our model hematite photoanode show good correlation between different methods for measurements carried out with the same light source, light intensity and potential. However, there is a considerable spread in the results obtained by different methods. For accurate determination of η t , we recommend IMPS measurements in operando with a bias light intensity such that the irradiance is as close as possible to the AM1.5 Global solar spectrum.

  8. Microarray image analysis: background estimation using quantile and morphological filters.

    PubMed

    Bengtsson, Anders; Bengtsson, Henrik

    2006-02-28

    In a microarray experiment the difference in expression between genes on the same slide is up to 103 fold or more. At low expression, even a small error in the estimate will have great influence on the final test and reference ratios. In addition to the true spot intensity the scanned signal consists of different kinds of noise referred to as background. In order to assess the true spot intensity background must be subtracted. The standard approach to estimate background intensities is to assume they are equal to the intensity levels between spots. In the literature, morphological opening is suggested to be one of the best methods for estimating background this way. This paper examines fundamental properties of rank and quantile filters, which include morphological filters at the extremes, with focus on their ability to estimate between-spot intensity levels. The bias and variance of these filter estimates are driven by the number of background pixels used and their distributions. A new rank-filter algorithm is implemented and compared to methods available in Spot by CSIRO and GenePix Pro by Axon Instruments. Spot's morphological opening has a mean bias between -47 and -248 compared to a bias between 2 and -2 for the rank filter and the variability of the morphological opening estimate is 3 times higher than for the rank filter. The mean bias of Spot's second method, morph.close.open, is between -5 and -16 and the variability is approximately the same as for morphological opening. The variability of GenePix Pro's region-based estimate is more than ten times higher than the variability of the rank-filter estimate and with slightly more bias. The large variability is because the size of the background window changes with spot size. To overcome this, a non-adaptive region-based method is implemented. Its bias and variability are comparable to that of the rank filter. The performance of more advanced rank filters is equal to the best region-based methods. However, in order to get unbiased estimates these filters have to be implemented with great care. The performance of morphological opening is in general poor with a substantial spatial-dependent bias.

  9. In situ quantitative analysis of individual H2O-CO2 fluid inclusions by laser Raman spectroscopy

    USGS Publications Warehouse

    Azbej, T.; Severs, M.J.; Rusk, B.G.; Bodnar, R.J.

    2007-01-01

    Raman spectral parameters for the Raman ??1 (1285??cm- 1) and 2??2 (1388??cm- 1) bands for CO2 and for the O-H stretching vibration band of H2O (3600??cm- 1) were determined in H2O-CO2 fluid inclusions. Synthetic fluid inclusions containing 2.5 to 50??mol% CO2 were analyzed at temperatures equal to or greater than the homogenization temperature. The results were used to develop an empirical relationship between composition and Raman spectral parameters. The linear peak intensity ratio (IR = ICO2/(ICO2 + IH2O)) is related to the CO2 concentration in the inclusion according to the relation:Mole % C O2 = e- 3.959 IR2 + 8.0734 IRwhere ICO2 is the intensity of the 1388 cm- 1 peak and IH2O is the intensity of the 3600 cm- 1 peak. The relationship between linear peak intensity and composition was established at 350????C for compositions ranging from 2.5 to 50??mol% CO2. The CO2-H2O linear peak intensity ratio (IR) varies with temperature and the relationship between composition and IR is strictly valid only if the inclusions are analyzed at 350????C. The peak area ratio is defined as AR = ACO2/(ACO2 + AH2O), where ACO2 is the integrated area under the 1388??cm- 1 peak and AH2O is the integrated area under the 3600??cm- 1 peak. The relationship between peak area ratio (AR) and the CO2 concentration in the inclusions is given as:Mole % C O2 = 312.5 AR. The equation relating peak area ratio and composition is valid up to 25??mol% CO2 and from 300 to 450????C. The relationship between linear peak intensity ratio and composition should be used for inclusions containing ??? 50??mol% CO2 and which can be analyzed at 350????C. The relationship between composition and peak area ratios should be used when analyzing inclusions at temperatures less than or greater than 350????C (300-450) but can only be used for compositions ??? 25??mol% CO2. Note that this latter relationship has a somewhat larger standard deviation compared to the intensity ratio relationship. Calibration relationships employing peak areas for both members of the Fermi diad (??1 at 1285??cm- 1 and 2??2 at 1388??cm- 1) were slightly poorer than those using only the 2??2 (1388??cm- 1) member owing to interference from quartz peak at approximately 1160??cm- 1. The technique has been applied to natural low-salinity H2O-CO2 inclusions from the Butte, Montana, porphyry copper-molybdenum deposit. Carbon dioxide concentrations obtained range from below detection to 4.2??mol% CO2, and are in good agreement with concentrations determined previously based on microthermometric and petrographic observations. ?? 2007 Elsevier B.V. All rights reserved.

  10. Elemental ratio measurements of organic compounds using aerosol mass spectrometry: Characterization, improved calibration, and implications

    DOE PAGES

    Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; ...

    2015-01-12

    Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state (OS C) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determinemore » elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H 2O + and CO + ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2O +, CO +, and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and especially H 2O + produced from many oxidized species. Combined AMS–vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.« less

  11. Stress Intensity Formulas for Three Dimensional Crack in the Vicinity of an Interface

    NASA Astrophysics Data System (ADS)

    Noda, Nao-Aki; Liang, Bin; Xu, Chunhui

    2008-02-01

    In this study, stress intensity factors are considered by using exact solutions available for cracks near an interface. The effect of crack shape on the stress intensity factors is studied with varying the aspect ratio of the cracks. Then, the stress intensity factors are expressed as formulas useful for engineering applications. The stress intensity factors for interface cracks and a crack in a functionally graded material are also discussed.

  12. The effect of a period of intensive exercise on the isoform test to detect growth hormone doping in sports.

    PubMed

    Voss, S C; Giraud, S; Alsayrafi, M; Bourdon, P C; Schumacher, Y O; Saugy, M; Robinson, N

    2013-08-01

    The major objective of this study was to investigate the effects of several days of intense exercise on growth hormone (hGH) testing using the World Anti-Doping Agencies hGH isoform differential immunoassays. Additionally the effects of circadian variation and exercise type on the isoform ratios were also investigated. 15 male athletes performed a simulated nine day cycling stage race. Blood samples were collected twice daily over a period of 15 days (stage race+three days before and after). hGH isoforms were analysed by the official WADA immunoassays (CMZ Assay GmbH). All measured isoform ratios were far below the WADA decision limits for an adverse analytical finding. Changes in the isoform ratios could not be clearly connected to circadian variation, exercise duration or intensity. The present study demonstrates that the hGH isoform ratios are not significantly affected by exercise or circadian variation. We demonstrated that heavy, long term exercise does not interfere with the decision limits for an adverse analytical finding. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Effects of Y/Gd Ratio and Boron Excess on Vacuum Ultraviolet Characteristics and Morphology of (Y,Gd)BO3:Eu Phosphor Particles Prepared by Spray Pyrolysis

    NASA Astrophysics Data System (ADS)

    Koo, Hye Young; Jung, Dae Soo; Hong, Seung Kwon; Kang, Yun Chan; Jung, Kyeong Youl

    2007-06-01

    (Y1-xGdx)BO3:Eu (0≤ x≤ 1) phosphor particles were prepared by spray pyrolysis. The optimal amount of boric acid for the high photoluminescence intensity of there particles differed depending on the molar ratio of Y to Gd. With decreasing Y/Gd molar ratio, an increasing amount of excess boric acid was required. The difference in excess quantity of boric acid, which was demanded for the highest photoluminescence intensity according to the Y/Gd ratio, influenced the morphology and mean size of the (Y,Gd)BO3:Eu phosphor particles. The (Y1-xGdx)BO3:Eu (0≤ x≤ 1) phosphor particles had a regular morphology. The mean sizes of the GdBO3:Eu and YBO3:Eu phosphor particles were 1.4 and 1 μm, respectively. The high reactivity of boron and yttrium components produced YBO3:Eu phosphor particles with high photoluminescence intensities by spray pyrolysis using a spray solution with a stoichiometric amount of boric acid.

  14. Ratiometric, single-dye, pH-sensitive inhibited laser-induced fluorescence for the characterization of mixing and mass transfer

    NASA Astrophysics Data System (ADS)

    Lacassagne, Tom; Simoëns, Serge; El Hajem, Mahmoud; Champagne, Jean-Yves

    2018-01-01

    Inhibited planar laser-induced fluorescence (I-PLIF) techniques are widely used for heat and mass transfer studies in fluid mechanics. They allow the visualization of instantaneous two-dimensional field of a passive or reactive scalar, providing that this scalar acts as an inhibitor to the fluorescence of a specific molecule, and that this molecule is homogeneously mixed in the fluid at a known concentration. Local scalar values are deduced from fluorescence recordings thanks to preliminary calibration procedure. When confronted with non-optically thin systems, however, the knowledge of the excitation intensity distribution in the region of interest is also required, and this information is most of the time hard to obtain. To overcome that problem, two-color ratiometric PLIF techniques ( {I}^ {r}-PLIF) have been developed. In these methods, the ratio of two different fluorescence wavelengths triggered by the same excitation is used as an indicator of the scalar value. Such techniques have been used for temperature measurements in several studies but never, to the author's knowledge, for pH tracking and acid-base mixing, despite the frequent use of the one-color version in mass transfer studies. In the present work, a ratiometric pH-sensitive-inhibited PLIF technique ( {I}_ {pH}^ {r}-PLIF) using fluorescein sodium as a single dye and applicable to complex geometries and flows is developed. Theoretical considerations show that the ratio of the two-color fluorescence intensities should only depend on the dye's spectral quantum yield, itself pH-dependent. A detailed spectrofluorimetric study of fluorescein reveals that this ratio strictly increases with the pH for two well-chosen spectral bands (fluorescence colors). A similar trend is found when using sCmos cameras equipped with optical filters to record fluorescence signals. The method is then experimented on a test flow, a turbulent acidic jet injected in an initially pH-neutral volume of fluid. The results obtained using the ratiometric version are consistent with single-color technique measurements, but excitation intensity heterogeneity is more efficiently accounted for, with a much smaller time needed for data treatment and without requiring the knowledge of laser paths across the fluid. This new technique is also able to reduce the impact of some unwanted experimental features such as time-varying excitation intensity or reflections at interfaces. It can be of great interest for further applications to multiphase mass transfer studies.

  15. Profile and Determinants of Retinal Optical Intensity in Normal Eyes with Spectral Domain Optical Coherence Tomography.

    PubMed

    Chen, Binyao; Gao, Enting; Chen, Haoyu; Yang, Jianling; Shi, Fei; Zheng, Ce; Zhu, Weifang; Xiang, Dehui; Chen, Xinjian; Zhang, Mingzhi

    2016-01-01

    To investigate the profile and determinants of retinal optical intensity in normal subjects using 3D spectral domain optical coherence tomography (SD OCT). A total of 231 eyes from 231 healthy subjects ranging in age from 18 to 80 years were included and underwent a 3D OCT scan. Forty-four eyes were randomly chosen to be scanned by two operators for reproducibility analysis. Distribution of optical intensity of each layer and regions specified by the Early Treatment of Diabetic Retinopathy Study (ETDRS) were investigated by analyzing the OCT raw data with our automatic graph-based algorithm. Univariate and multivariate analyses were performed between retinal optical intensity and sex, age, height, weight, spherical equivalent (SE), axial length, image quality, disc area and rim/disc area ratio (R/D area ratio). For optical intensity measurements, the intraclass correlation coefficient of each layer ranged from 0.815 to 0.941, indicating good reproducibility. Optical intensity was lowest in the central area of retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, inner nuclear layer, outer plexiform layer and photoreceptor layer, except for the retinal pigment epithelium (RPE). Optical intensity was positively correlated with image quality in all retinal layers (0.553<β<0.851, p<0.01), and negatively correlated with age in most retinal layers (-0.362<β<-0.179, p<0.01), except for the RPE (β = 0.456, p<0.01), outer nuclear layer and photoreceptor layer (p>0.05). There was no relationship between retinal optical intensity and sex, height, weight, SE, axial length, disc area and R/D area ratio. There was a specific pattern of distribution of retinal optical intensity in different regions. The optical intensity was affected by image quality and age. Image quality can be used as a reference for normalization. The effect of age needs to be taken into consideration when using OCT for diagnosis.

  16. Cost-effectiveness of intensive multifactorial treatment compared with routine care for individuals with screen-detected Type 2 diabetes: analysis of the ADDITION-UK cluster-randomized controlled trial

    PubMed Central

    Tao, L; Wilson, E C F; Wareham, N J; Sandbæk, A; Rutten, G E H M; Lauritzen, T; Khunti, K; Davies, M J; Borch-Johnsen, K; Griffin, S J; Simmons, R K

    2015-01-01

    Aims To examine the short- and long-term cost-effectiveness of intensive multifactorial treatment compared with routine care among people with screen-detected Type 2 diabetes. Methods Cost–utility analysis in ADDITION-UK, a cluster-randomized controlled trial of early intensive treatment in people with screen-detected diabetes in 69 UK general practices. Unit treatment costs and utility decrement data were taken from published literature. Accumulated costs and quality-adjusted life years (QALYs) were calculated using ADDITION-UK data from 1 to 5 years (short-term analysis, n = 1024); trial data were extrapolated to 30 years using the UKPDS outcomes model (version 1.3) (long-term analysis; n = 999). All costs were transformed to the UK 2009/10 price level. Results Adjusted incremental costs to the NHS were £285, £935, £1190 and £1745 over a 1-, 5-, 10- and 30-year time horizon, respectively (discounted at 3.5%). Adjusted incremental QALYs were 0.0000, – 0.0040, 0.0140 and 0.0465 over the same time horizons. Point estimate incremental cost-effectiveness ratios (ICERs) suggested that the intervention was not cost-effective although the ratio improved over time: the ICER over 10 years was £82 250, falling to £37 500 over 30 years. The ICER fell below £30 000 only when the intervention cost was below £631 per patient: we estimated the cost at £981. Conclusion Given conventional thresholds of cost-effectiveness, the intensive treatment delivered in ADDITION was not cost-effective compared with routine care for individuals with screen-detected diabetes in the UK. The intervention may be cost-effective if it can be delivered at reduced cost. PMID:25661661

  17. The development of methods of analysis of documents on the basis of the methods of Raman spectroscopy and fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Gorshkova, Kseniia O.; Tumkin, Ilya I.; Kirillova, Elizaveta O.; Panov, Maxim S.; Kochemirovsky, Vladimir A.

    2017-05-01

    The investigation of natural aging of writing inks printed on paper using Raman spectroscopy was performed. Based on the obtained dependencies of the Raman peak intensities ratios on the exposure time, the dye degradation model was proposed. It was suggested that there are several competing bond breaking and bond forming reactions corresponding to the characteristic vibration frequencies of the dye molecule that simultaneously occur during ink aging process. Also we propose a methodology based on the study of the optical properties of paper, particularly changes in the fluorescence of optical brighteners included in its composition as well as the paper reflectivity using spectrophotometric methods. These results can be implemented to develop the novel and promising method of criminology.

  18. Nanoscale deformation and fracture mechanics of polycrystalline silicon and diamond-like carbon for MEMS by the AFM/DIC method

    NASA Astrophysics Data System (ADS)

    Cho, Sung Woo

    A method for nanoscale experimental mechanics was developed to address problems in deformation and fracture of micron-scale components in Microelectromechanical Systems (MEMS). Specifically, the effective and local, elastic and fracture behavior of polycrystalline silicon (polysilicon) and tetrahedral amorphous diamond-like carbon (ta-C) were studied using freestanding thin films subject to uniaxial tension. In this method, direct measurements of local deformations were derived from Atomic Force Microscopy (AFM) images in specimen areas varying between 1x2 mum2 and 15x15 mum2 using Digital Image Correlation (DIC) to extract displacements and strains with spatial resolution of 1-2 nm. The effective elastic modulus and Poisson's ratio of polysilicon and ta-C from the Sandia National Laboratories (SUMMiT) were 155 +/- 6 GPa and 0.22 +/- 0.02, and 759 +/- 22 GPa and 0.17 +/- 0.03, respectively. Similarly, the elastic modulus and Poisson's ratio of polysilicon fabricated at MCNC via the Multi-User MEMS Processes (MUMPs) with <110> texture were 164 +/- 7 GPa and 0.22 +/- 0.02, respectively. A second problem studied using the AFM/DIC method was the fracture of polysilicon in the presence of atomically sharp cracks. The effective (macroscopic) Mode-I critical stress intensity factor for polysilicon from different MUMPs runs was 1.00 +/- 0.1 MPa√m, where 0.1 MPa√m was the standard deviation, attributed to local cleavage anisotropy and grain boundary toughening. The variation in the effective critical stress intensity factor and the subcritical crack growth of polysilicon that was spatially recorded and quantified for the first time were the result of the spatial variation of the 4 local stress intensity factor at the crack tip that controlled crack initiation and thus, the overall fracture process. The AFM/DIC method was also applied to determine the minimum size of a polysilicon domain whose effective mechanical behavior could be described by the isotropic elastic constants. The isotropic material constants are applicable to MEMS components comprised of at least 15x15 grains, which correspond to a specimen area of 10x10-mum2 for SUMMiT and of 5x5-mum2 for MUMPs polysilicon, respectively.

  19. Approaches of aroma extraction dilution analysis (AEDA) for headspace solid phase microextraction and gas chromatography-olfactometry (HS-SPME-GC-O): Altering sample amount, diluting the sample or adjusting split ratio?

    PubMed

    Feng, Yunzi; Cai, Yu; Sun-Waterhouse, Dongxiao; Cui, Chun; Su, Guowan; Lin, Lianzhu; Zhao, Mouming

    2015-11-15

    Aroma extract dilution analysis (AEDA) is widely used for the screening of aroma-active compounds in gas chromatography-olfactometry (GC-O). In this study, three aroma dilution methods, (I) using different test sample volumes, (II) diluting samples, and (III) adjusting the GC injector split ratio, were compared for the analysis of volatiles by using HS-SPME-AEDA. Results showed that adjusting the GC injector split ratio (III) was the most desirable approach, based on the linearity relationships between Ln (normalised peak area) and Ln (normalised flavour dilution factors). Thereafter this dilution method was applied in the analysis of aroma-active compounds in Japanese soy sauce and 36 key odorants were found in this study. The most intense aroma-active components in Japanese soy sauce were: ethyl 2-methylpropanoate, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, ethyl 4-methylpentanoate, 3-(methylthio)propanal, 1-octen-3-ol, 2-methoxyphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-vinylphenol, 2-phenylethanol, and 4-hydroxy-5-ethyl-2-methyl-3(2H)-furanone. Copyright © 2015. Published by Elsevier Ltd.

  20. Particle shape inhomogeneity and plasmon-band broadening of solar-control LaB6 nanoparticles

    NASA Astrophysics Data System (ADS)

    Machida, Keisuke; Adachi, Kenji

    2015-07-01

    An ensemble inhomogeneity of non-spherical LaB6 nanoparticles dispersion has been analyzed with Mie theory to account for the observed broad plasmon band. LaB6 particle shape has been characterized using small-angle X-ray scattering (SAXS) and electron tomography (ET). SAXS scattering intensity is found to vary exponentially with exponent -3.10, indicating the particle shape of disk toward sphere. ET analysis disclosed dually grouped distribution of nanoparticle dispersion; one is large-sized at small aspect ratio and the other is small-sized with scattered high aspect ratio, reflecting the dual fragmentation modes during the milling process. Mie extinction calculations have been integrated for 100 000 particles of varying aspect ratio, which were produced randomly by using the Box-Muller method. The Mie integration method has produced a broad and smooth absorption band expanded towards low energy, in remarkable agreement with experimental profiles by assuming a SAXS- and ET-derived shape distribution, i.e., a majority of disks with a little incorporation of rods and spheres for the ensemble. The analysis envisages a high potential of LaB6 with further-increased visible transparency and plasmon peak upon controlled particle-shape and its distribution.

  1. Polarimetric imaging of retinal disease by polarization sensitive SLO

    NASA Astrophysics Data System (ADS)

    Miura, Masahiro; Elsner, Ann E.; Iwasaki, Takuya; Goto, Hiroshi

    2015-03-01

    Polarimetry imaging is used to evaluate different features of the macular disease. Polarimetry images were recorded using a commercially- available polarization-sensitive scanning laser opthalmoscope at 780 nm (PS-SLO, GDx-N). From data sets of PS-SLO, we computed average reflectance image, depolarized light images, and ratio-depolarized light images. The average reflectance image is the grand mean of all input polarization states. The depolarized light image is the minimum of crossed channel. The ratio-depolarized light image is a ratio between the average reflectance image and depolarized light image, and was used to compensate for variation of brightness. Each polarimetry image is compared with the autofluorescence image at 800 nm (NIR-AF) and autofluorescence image at 500 nm (SW-AF). We evaluated four eyes with geographic atrophy in age related macular degeneration, one eye with retinal pigment epithelium hyperplasia, and two eyes with chronic central serous chorioretinopathy. Polarization analysis could selectively emphasize different features of the retina. Findings in ratio depolarized light image had similarities and differences with NIR-AF images. Area of hyper-AF in NIR-AF images showed high intensity areas in the ratio depolarized light image, representing melanin accumulation. Areas of hypo-AF in NIR-AF images showed low intensity areas in the ratio depolarized light images, representing melanin loss. Drusen were high-intensity areas in the ratio depolarized light image, but NIR-AF images was insensitive to the presence of drusen. Unlike NIR-AF images, SW-AF images showed completely different features from the ratio depolarized images. Polarization sensitive imaging is an effective tool as a non-invasive assessment of macular disease.

  2. The metallicities of the broad emission line regions in the nitrogen-loudest quasars

    NASA Astrophysics Data System (ADS)

    Batra, Neelam Dhanda; Baldwin, Jack A.

    2014-03-01

    We measured the metallicity Z in the broad emission-line regions (BELRs) of 43 Sloan Digital Sky Survey (SDSS) quasars with the strongest N IV] and N III] emission lines. These N-loud quasi-stellar objects (QSOs) have unusually low-black-hole masses. We used the intensity ratio of N lines to collisionally excited emission lines of other heavy elements to find metallicities in their BELR regions. We found that seven of the eight line-intensity ratios that we employed give roughly consistent metallicities as measured, but that for each individual QSO their differences from the mean of all metallicity measurements depend on the ionization potential of the ions that form the emission lines. After correcting for this effect, the different line-intensity ratios give metallicities that generally agree to within the 0.24 dex uncertainty in the measurements of the line-intensity ratios. The metallicities are very high, with mean log Z for the whole sample of 5.5 Z⊙ and a maximum of 18 Z⊙. Our results argue against the possibility that the strong N lines represent an overabundance only of N but not of all heavy elements. They are compatible with either that (1) the BELR gas has been chemically enriched by the general stellar population in the central bulge of the host galaxy, but the locally optimally emitting cloud model used in the analysis needs some fine tuning or (2) that instead this gas has been enriched by intense star formation on the very local scale of the active nucleus that has resulted in an abundance gradient within the BELR.

  3. Correlated peak relative light intensity and peak current in triggered lightning subsequent return strokes

    NASA Technical Reports Server (NTRS)

    Idone, V. P.; Orville, R. E.

    1985-01-01

    The correlation between peak relative light intensity L(R) and stroke peak current I(R) is examined for 39 subsequent return strokes in two triggered lightning flashes. One flash contained 19 strokes and the other 20 strokes for which direct measurements were available of the return stroke peak current at ground. Peak currents ranged from 1.6 to 21 kA. The measurements of peak relative light intensity were obtained from photographic streak recordings using calibrated film and microsecond resolution. Correlations, significant at better than the 0.1 percent level, were found for several functional relationships. Although a relation between L(R) and I(R) is evident in these data, none of the analytical relations considered is clearly favored. The correlation between L(R) and the maximum rate of current rise is also examined, but less correlation than between L(R) and I(R) is found. In addition, the peak relative intensity near ground is evaluated for 22 dart leaders, and a mean ratio of peak dart leader to peak return stroke relative light intensity was found to be 0.1 with a range of 0.02-0.23. Using two different methods, the peak current near ground in these dart leaders is estimated to range from 0.1 to 6 kA.

  4. Consolidation of fatigue and fatigue-crack-propagation data for design use

    NASA Technical Reports Server (NTRS)

    Rice, R. C.; Davies, K. B.; Jaske, C. E.; Feddersen, C. E.

    1975-01-01

    Analytical methods developed for consolidation of fatigue and fatigue-crack-propagation data for use in design of metallic aerospace structural components are evaluated. A comprehensive file of data on 2024 and 7075 aluminums, Ti-6Al-4V alloy, and 300M steel was established by obtaining information from both published literature and reports furnished by aerospace companies. Analyses are restricted to information obtained from constant-amplitude load or strain cycling of specimens in air at room temperature. Both fatigue and fatigue-crack-propagation data are analyzed on a statistical basis using a least-squares regression approach. For fatigue, an equivalent strain parameter is used to account for mean stress or stress ratio effects and is treated as the independent variable; cyclic fatigue life is considered to be the dependent variable. An effective stress-intensity factor is used to account for the effect of load ratio on fatigue-crack-propagation and treated as the independent variable. In this latter case, crack-growth rate is considered to be the dependent variable. A two term power function is used to relate equivalent strain to fatigue life, and an arc-hyperbolic-tangent function is used to relate effective stress intensity to crack-growth rate.

  5. Limits on Achievable Dimensional and Photon Efficiencies with Intensity-Modulation and Photon-Counting Due to Non-Ideal Photon-Counter Behavior

    NASA Technical Reports Server (NTRS)

    Moision, Bruce; Erkmen, Baris I.; Farr, William; Dolinar, Samuel J.; Birnbaum, Kevin M.

    2012-01-01

    An ideal intensity-modulated photon-counting channel can achieve unbounded photon information efficiencies (PIEs). However, a number of limitations of a physical system limit the practically achievable PIE. In this paper, we discuss several of these limitations and illustrate their impact on the channel. We show that, for the Poisson channel, noise does not strictly bound PIE, although there is an effective limit, as the dimensional information efficiency goes as e[overline] e PIE beyond a threshold PIE. Since the Holevo limit is bounded in the presence of noise, this illustrates that the Poisson approximation is invalid at large PIE for any number of noise modes. We show that a finite transmitter extinction ratio bounds the achievable PIE to a maximum that is logarithmic in the extinction ratio. We show how detector jitter limits the ability to mitigate noise in the PPM signaling framework. We illustrate a method to model detector blocking when the number of detectors is large, and illustrate mitigation of blocking with spatial spreading and altering. Finally, we illustrate the design of a high photon efficiency system using state-of-the-art photo-detectors and taking all these effects into account.

  6. An optimized immunohistochemistry protocol for detecting the guidance cue Netrin-1 in neural tissue.

    PubMed

    Salameh, Samer; Nouel, Dominique; Flores, Cecilia; Hoops, Daniel

    2018-01-01

    Netrin-1, an axon guidance protein, is difficult to detect using immunohistochemistry. We performed a multi-step, blinded, and controlled protocol optimization procedure to establish an efficient and effective fluorescent immunohistochemistry protocol for characterizing Netrin-1 expression. Coronal mouse brain sections were used to test numerous antigen retrieval methods and combinations thereof in order to optimize the stain quality of a commercially available Netrin-1 antibody. Stain quality was evaluated by experienced neuroanatomists for two criteria: signal intensity and signal-to-noise ratio. After five rounds of testing protocol variants, we established a modified immunohistochemistry protocol that produced a Netrin-1 signal with good signal intensity and a high signal-to-noise ratio. The key protocol modifications are as follows: •Use phosphate buffer (PB) as the blocking solution solvent.•Use 1% sodium dodecyl sulfate (SDS) treatment for antigen retrieval. The original protocol was optimized for use with the Netrin-1 antibody produced by Novus Biologicals. However, we subsequently further modified the protocol to work with the antibody produced by Abcam. The Abcam protocol uses PBS as the blocking solution solvent and adds a citrate buffer antigen retrieval step.

  7. Evidence-based human resource management: a study of nurse leaders' resource allocation.

    PubMed

    Fagerström, Lisbeth

    2009-05-01

    The aims were to illustrate how the RAFAELA system can be used to facilitate evidence-based human resource management. The theoretical framework of the RAFAELA system is based on a holistic view of humankind and a view of leadership founded on human resource management. Nine wards from three central hospitals in Finland participated in the study. The data, stemming from 2006-2007, were taken from the critical indicators (ward-related and nursing intensity information) for national benchmarking used in the RAFAELA system. The data were analysed descriptively. The daily nursing resources per classified patient ratio is a more specific method of measurement than the nurse-to-patient ratio. For four wards, the nursing intensity per nurse surpassed the optimal level 34% to 62.2% of days. Resource allocation was clearly improved in that a better balance between patients' care needs and available nursing resources was maintained. The RAFAELA system provides a rational, systematic and objective foundation for evidence-based human resource management. Data from a systematic use of the RAFAELA system offer objective facts and motives for evidence-based decision making in human resource management, and will therefore enhance the nurse leaders' evidence and scientific based way of working.

  8. Hysteretic energy prediction method for mainshock-aftershock sequences

    NASA Astrophysics Data System (ADS)

    Zhai, Changhai; Ji, Duofa; Wen, Weiping; Li, Cuihua; Lei, Weidong; Xie, Lili

    2018-04-01

    Structures located in seismically active regions may be subjected to mainshock-aftershock (MSAS) sequences. Strong aftershocks significantly affect the hysteretic energy demand of structures. The hysteretic energy, E H,seq, is normalized by mass m and expressed in terms of the equivalent velocity, V D,seq, to quantitatively investigate aftershock effects on the hysteretic energy of structures. The equivalent velocity, V D,seq, is computed by analyzing the response time-history of an inelastic single-degree-of-freedom (SDOF) system with a varying vibration period subjected to 309 MSAS sequences. The present study selected two kinds of MSAS sequences, with one aftershock and two aftershocks, respectively. The aftershocks are scaled to maintain different relative intensities. The variation of the equivalent velocity, V D,seq, is studied for consideration of the ductility values, site conditions, relative intensities, number of aftershocks, hysteretic models, and damping ratios. The MSAS sequence with one aftershock exhibited a 10% to 30% hysteretic energy increase, whereas the MSAS sequence with two aftershocks presented a 20% to 40% hysteretic energy increase. Finally, a hysteretic energy prediction equation is proposed as a function of the vibration period, ductility value, and damping ratio to estimate hysteretic energy for mainshock-aftershock sequences.

  9. Upconverting nanocrystals as luminescent temperature probes for local-heating imaging during direct laser writing 3D nanolithography

    NASA Astrophysics Data System (ADS)

    Varapnickas, Simonas; Baziulytė-Paulavičienė, Dovilė; Šakirzanovas, Simas; Malinauskas, Mangirdas

    2018-01-01

    Luminescence measurements of upconverting nanocrystals (UCNCs) dispersed in SZ2080 prepolymer being pro- cessed by direct laser writing (DLW) nanopolymerization technique are presented. Er3+ ions doped β-NaYbF4 and Er3+,Yb3+ co-doped β-NaGdF4 core and core-shell UCNCs were prepared by a thermal decomposition method. The ratio of the 2H11/2 -> 4I15/2 and 4S3/2 -> 4I15/2 emission intensities under λ = 975 nm excitation was confirmed to follow Boltzmann-type distribution in the temperature range from 20 °C to 200 °C and enabled a self-referenced optical readout of the sample temperature changes. Variation of thermally-coupled spectral bands fluorescence intensity ratio (FIR) was observed while prepolymer being processed under typical DLW conditions (1030 nm, 300 fs, 200 kHz, NA = 0.8) and Epulse varying from below modification threshold to the optical breakdown. Average fitted temperature changes around polymerized voxel measured ΔT1 < 30 °C within polymerization window and increases up to ΔT2 100 °C in overexposing regime.

  10. Comparison of noncovalent interactions of zigzag and armchair carbon nanotubes with heterocyclic and aromatic compounds: Imidazole and benzene, imidazophenazines, and tetracene

    NASA Astrophysics Data System (ADS)

    Zarudnev, Eugene S.; Stepanian, Stepan G.; Adamowicz, Ludwik; Leontiev, Victor S.; Karachevtsev, Victor A.

    2017-02-01

    We study non-covalent functionalization of SWCNT by linear heterocyclic compounds such as imidazophenazine (F1) and its derivatives (F2-F4). MP2 and DFT/M05-2X quantum-chemical methods are used to determine the structures and the interaction energies of complexes formed by F1-F4 with the zigzag(10,10) and armchair(6,6) nanotubes. The calculations show that for small diameter nanotubes the binding energies with zigzag nanotubes are stronger than with armchair nanotubes. But above the diameter of 1.4 nm the interaction energies for the armchair nanotubes become larger than for the zigzag nanotubes. Experimental measurements demonstrates that the ratio of the integral intensity of the resonance Raman bands assigned to the RBM modes of semiconducting nanotubes to the integral intensity of the metallic nanotubes increases for supernatant of SWCNT:F4 (1,2,3-triazole-[4,5-d]-phenazine) hybrids solved in 1-Methyl-2-pyrrolidone as compared to this ratio in sediment samples. It demonstrates that the linear heterocyclic compounds can be used for separating SWCNTs with different electron-conduction types.

  11. Edge grouping combining boundary and region information.

    PubMed

    Stahl, Joachim S; Wang, Song

    2007-10-01

    This paper introduces a new edge-grouping method to detect perceptually salient structures in noisy images. Specifically, we define a new grouping cost function in a ratio form, where the numerator measures the boundary proximity of the resulting structure and the denominator measures the area of the resulting structure. This area term introduces a preference towards detecting larger-size structures and, therefore, makes the resulting edge grouping more robust to image noise. To find the optimal edge grouping with the minimum grouping cost, we develop a special graph model with two different kinds of edges and then reduce the grouping problem to finding a special kind of cycle in this graph with a minimum cost in ratio form. This optimal cycle-finding problem can be solved in polynomial time by a previously developed graph algorithm. We implement this edge-grouping method, test it on both synthetic data and real images, and compare its performance against several available edge-grouping and edge-linking methods. Furthermore, we discuss several extensions of the proposed method, including the incorporation of the well-known grouping cues of continuity and intensity homogeneity, introducing a factor to balance the contributions from the boundary and region information, and the prevention of detecting self-intersecting boundaries.

  12. Influences of two high intensity interval exercise protocols on the main determinants of blood fluidity in overweight men.

    PubMed

    Ahmadizad, Sajad; Bassami, Minoo; Hadian, Mohsen; Eslami, Maryam

    2016-01-01

    Acute effects of continuous exercise on the markers of blood fluidity have been addressed in different populations and the changes are intensity related. However, the effect of different high intensity interval exercise (HIIE) on these variables is unclear. This study is designed to determine the effects of two different HIIE with different work/rest ratios but the same energy expenditure on the main determinants of blood fluidity. Ten overweight men (age, 26.3±1.7 yrs) completed two HIIE protocols on two separate occasions with one week intervening. The two HIIE encompassed performing: 1) 6 intervals of 2 min activity at 85% of VO2max interspersed by 2 min active recovery at 30% of VO2max (ratio 1 to 1, HIIE1/1), and 2) 6 intervals of 30 s activity at 110% of VO2max interspersed by 4 min active recovery at 40% of VO2max (ratio 1 to 8, HIIE1/8). Each exercise trial was followed by 30 min rest. Venous blood samples were obtained before exercise, immediately after exercise and after recovery and analyzed for blood and plasma viscosity, fibrinogen and red blood cell indices. The HIIE1/1 protocol led to higher reduction (P < 0.01) in plasma volume changes compared to HIIE1/8 (9.9% vs 5.7%). Moreover, increases in blood viscosity, plasma viscosity, hematocrit, RBC count and mean arterial blood pressure observed following HIIE1/1 were significantly (P < 0.05) higher than HIIE1/8 ; whereas, the changes in fibrinogen concentration neither were significant in response to both trials nor were significantly different between two protocols (P > 0.05). However, the changes in all variables during exercise were transient and returned to the baseline levels after 30 min recovery. It is concluded that the HIIE protocol with lower intensity and shorter rest intervals (higher work to rest ratio) clearly results in more physiological strain than HIIE with higher intensity but longer rest intervals (lower work to rest ratio) in overweight individuals, and that the work to rest ratio could be as important as exercise intensity when considering the hemorheological variables during HIIE.

  13. A spectroscopic study using line ratios of lithiumlike ions in a laser-produced plasma

    NASA Astrophysics Data System (ADS)

    Moreno, J. C.; Goldsmith, S.; Griem, H. R.

    1989-02-01

    Spectra of highly ionized titanium and calcium in the extreme ultraviolet region were observed in laser-produced plasmas using the OMEGA 24 beam (351 nm) laser system at the University of Rochester. The plasmas were produced using glass microballoon targets coated with a layer of a medium Z element and a layer of parylene (CH). Time-integrated electron temperatures and densities were obtained by comparing measured line intensity ratios of lithiumlike charge states of Ti and Ca to numerical calculations from a collisional-radiative model. The variation of line intensity ratios with electron density and temperature using the collisional-radiative model is discussed.

  14. Magnetic Resonance Imaging Parameters in Predicting the Treatment Outcome of High-intensity Focused Ultrasound Ablation of Uterine Fibroids With an Immediate Nonperfused Volume Ratio of at Least 90.

    PubMed

    Keserci, Bilgin; Duc, Nguyen Minh

    2018-03-07

    We aimed to investigate the role of magnetic resonance imaging parameters in predicting the treatment outcome of high-intensity focused ultrasound (HIFU) ablation of uterine fibroids with a nonperfused volume (NPV) ratio of at least 90%. A total of 120 women who underwent HIFU treatment were divided into groups 1 (n = 72) and 2 (n = 48), comprising patients with an NPV ratio of at least 90% and less than 90%, respectively. Multivariate logistic regression analyses were carried out to investigate the potential predictors of the NPV ratio of at least 90%. The NPV ratios immediately post-treatment, therapeutic efficacy at 6 months' follow-up, and safety in terms of adverse effects and changes in anti-Mullerian hormone level were assessed. By introducing multiple predictors obtained from multivariate analyses into a generalized estimating equation model, the results showed that the thickness of the subcutaneous fat layer in the anterior abdominal wall, peak enhancement of fibroid, time to peak of fibroid, and the ratio of area under the curve of fibroid to myometrium were statistically significant, except T2 signal intensity ratio of fibroid to myometrium, hence predicting an NPV ratio of at least 90%. No serious adverse effects and no significant difference between the anti-Mullerian hormone levels before or 6 months post-treatment were reported. The findings in this study suggest that the achievement of NPV ratio of at least 90% in magnetic resonance imaging-guided HIFU treatment of uterine fibroids based on prediction model appears clinically possible without compromising the safety of patients. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. Plasmonic nanorod arrays of a two-segment dimer and a coaxial cable with 1 nm gap for large field confinement and enhancement

    NASA Astrophysics Data System (ADS)

    Cheng, Zi-Qiang; Nan, Fan; Yang, Da-Jie; Zhong, Yu-Ting; Ma, Liang; Hao, Zhong-Hua; Zhou, Li; Wang, Qu-Quan

    2015-01-01

    Seeking plasmonic nanostructures with large field confinement and enhancement is significant for photonic and electronic nanodevices with high sensitivity, reproducibility, and tunability. Here, we report the synthesis of plasmonic arrays composed of two-segment dimer nanorods and coaxial cable nanorods with ~1 nm gap insulated by a self-assembled Raman molecule monolayer. The gap-induced plasmon coupling generates an intense field in the gap region of the dimer junction and the cable interlayer. As a result, the longitudinal plasmon resonance of nanorod arrays with high tunability is obviously enhanced. Most interestingly, the field enhancement of dimer nanorod arrays can be tuned by the length ratio L1/L2 of the two segments, and the maximal enhancement appears at L1/L2 = 1. In that case, the two-photon luminescence (TPL) of dimer nanorod arrays and the Raman intensity in the dimer junction is enhanced by 27 and 30 times, respectively, under resonant excitation. In the same way, the Raman intensity in the gap region is enhanced 16 times for the coaxial cable nanorod arrays. The plasmonic nanorod arrays synthesized by the facile method, having tunable plasmon properties and large field enhancement, indicate an attractive pathway to the photonic nanodevices.Seeking plasmonic nanostructures with large field confinement and enhancement is significant for photonic and electronic nanodevices with high sensitivity, reproducibility, and tunability. Here, we report the synthesis of plasmonic arrays composed of two-segment dimer nanorods and coaxial cable nanorods with ~1 nm gap insulated by a self-assembled Raman molecule monolayer. The gap-induced plasmon coupling generates an intense field in the gap region of the dimer junction and the cable interlayer. As a result, the longitudinal plasmon resonance of nanorod arrays with high tunability is obviously enhanced. Most interestingly, the field enhancement of dimer nanorod arrays can be tuned by the length ratio L1/L2 of the two segments, and the maximal enhancement appears at L1/L2 = 1. In that case, the two-photon luminescence (TPL) of dimer nanorod arrays and the Raman intensity in the dimer junction is enhanced by 27 and 30 times, respectively, under resonant excitation. In the same way, the Raman intensity in the gap region is enhanced 16 times for the coaxial cable nanorod arrays. The plasmonic nanorod arrays synthesized by the facile method, having tunable plasmon properties and large field enhancement, indicate an attractive pathway to the photonic nanodevices. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05544f

  16. Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS.

    PubMed

    Kappel, S; Boulyga, S F; Dorta, L; Günther, D; Hattendorf, B; Koffler, D; Laaha, G; Leisch, F; Prohaska, T

    2013-03-01

    Data evaluation is a crucial step when it comes to the determination of accurate and precise isotope ratios computed from transient signals measured by multi-collector-inductively coupled plasma mass spectrometry (MC-ICPMS) coupled to, for example, laser ablation (LA). In the present study, the applicability of different data evaluation strategies (i.e. 'point-by-point', 'integration' and 'linear regression slope' method) for the computation of (235)U/(238)U isotope ratios measured in single particles by LA-MC-ICPMS was investigated. The analyzed uranium oxide particles (i.e. 9073-01-B, CRM U010 and NUSIMEP-7 test samples), having sizes down to the sub-micrometre range, are certified with respect to their (235)U/(238)U isotopic signature, which enabled evaluation of the applied strategies with respect to precision and accuracy. The different strategies were also compared with respect to their expanded uncertainties. Even though the 'point-by-point' method proved to be superior, the other methods are advantageous, as they take weighted signal intensities into account. For the first time, the use of a 'finite mixture model' is presented for the determination of an unknown number of different U isotopic compositions of single particles present on the same planchet. The model uses an algorithm that determines the number of isotopic signatures by attributing individual data points to computed clusters. The (235)U/(238)U isotope ratios are then determined by means of the slopes of linear regressions estimated for each cluster. The model was successfully applied for the accurate determination of different (235)U/(238)U isotope ratios of particles deposited on the NUSIMEP-7 test samples.

  17. Separating Dust Mixtures and Other External Aerosol Mixtures Using Airborne High Spectral Resolution Lidar Data

    NASA Astrophysics Data System (ADS)

    Burton, S. P.; Ferrare, R. A.; Vaughan, M.; Hostetler, C. A.; Rogers, R. R.; Hair, J. W.; Cook, A. L.; Harper, D. B.

    2013-12-01

    Knowledge of aerosol type is important for source attribution and for determining the magnitude and assessing the consequences of aerosol radiative forcing. The NASA Langley Research Center airborne High Spectral Resolution Lidar (HSRL-1) has acquired considerable datasets of both aerosol extensive parameters (e.g. aerosol optical depth) and intensive parameters (e.g. aerosol depolarization ratio, lidar ratio) that can be used to infer aerosol type. An aerosol classification methodology has been used extensively to classify HSRL-1 aerosol measurements of different aerosol types including dust, smoke, urban pollution, and marine aerosol. However, atmospheric aerosol is frequently not a single pure type, but instead occurs as a mixture of types, and this mixing affects the optical and radiative properties of the aerosol. Here we present a comprehensive and unified set of rules for characterizing external mixtures using several key aerosol intensive parameters: extinction-to-backscatter ratio (i.e. lidar ratio), backscatter color ratio, and depolarization ratio. Our mixing rules apply not just to the scalar values of aerosol intensive parameters, but to multi-dimensional normal distributions with variance in each measurement dimension. We illustrate the applicability of the mixing rules using examples of HSRL-1 data where mixing occurred between different aerosol types, including advected Saharan dust mixed with the marine boundary layer in the Caribbean Sea and locally generated dust mixed with urban pollution in the Mexico City surroundings. For each of these cases we infer a time-height cross section of mixing ratio along the flight track and we partition aerosol extinction into portions attributed to the two pure types. Since multiple aerosol intensive parameters are measured and included in these calculations, the techniques can also be used for cases without significant depolarization (unlike similar work by earlier researchers), and so a third example of a mixture of smoke plus marine aerosol is also explored.

  18. Spectroscopic investigations of microwave generated plasmas

    NASA Technical Reports Server (NTRS)

    Hawley, Martin C.; Haraburda, Scott S.; Dinkel, Duane W.

    1991-01-01

    The study deals with the plasma behavior as applied to spacecraft propulsion from the perspective of obtaining better design and modeling capabilities. The general theory of spectroscopy is reviewed, and existing methods for converting emission-line intensities into such quantities as temperatures and densities are outlined. Attention is focused on the single-atomic-line and two-line radiance ratio methods, atomic Boltzmann plot, and species concentration. Electronic temperatures for a helium plasma are determined as a function of pressure and a gas-flow rate using these methods, and the concentrations of ions and electrons are predicted from the Saha-Eggert equations using the sets of temperatures obtained as a function of the gas-flow rate. It is observed that the atomic Boltzmann method produces more reliable results for the electronic temperature, while the results obtained from the single-line method reflect the electron temperatures accurately.

  19. Fracture behavior of glass fiber reinforced polymer composite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avci, A.; Arikan, H.; Akdemir, A

    2004-03-01

    Chopped strand glass fiber reinforced particle-filled polymer composite beams with varying notch-to-depth ratios and different volume fractions of glass fibers were investigated in Mode I fracture using three-point bending tests. Effects of polyester resin content and glass fiber content on fracture behavior was also studied. Polyester resin contents were used 13.00%%, 14.75%, 16.50%, 18.00% and 19.50%, and glass fiber contents were 1% and 1.5% of the total weight of the polymer composite system. Flexural strength of the polymer composite increases with increase in polyester and fiber content. The critical stress intensity factor was determined by using several methods such asmore » initial notch depth method, compliance method and J-integral method. The values of K{sub IC} obtained from these methods were compared.« less

  20. Physical activity and risk of ischemic stroke in the Northern Manhattan Study

    PubMed Central

    Willey, J Z.; Moon, Y P.; Paik, M C.; Boden-Albala, B; Sacco, R L.; Elkind, M S.V.

    2009-01-01

    Background: It is controversial whether physical activity is protective against first stroke among older persons. We sought to examine whether physical activity, as measured by intensity of exercise and energy expended, is protective against ischemic stroke. Methods: The Northern Manhattan Study is a prospective cohort study in older, urban-dwelling, multiethnic, stroke-free individuals. Baseline measures of leisure-time physical activity were collected via in-person questionnaires. Cox proportional hazards models were constructed to examine whether energy expended and intensity of physical activity were associated with the risk of incident ischemic stroke. Results: Physical inactivity was present in 40.5% of the cohort. Over a median follow-up of 9.1 years, there were 238 incident ischemic strokes. Moderate- to heavy-intensity physical activity was associated with a lower risk of ischemic stroke (adjusted hazard ratio [HR] 0.65, 95% confidence interval [0.44–0.98]). Engaging in any physical activity vs none (adjusted HR 1.16, 95% CI 0.88–1.51) and energy expended in kcal/wk (adjusted HR per 500-unit increase 1.01, 95% CI 0.99–1.03) were not associated with ischemic stroke risk. There was an interaction of sex with intensity of physical activity (p = 0.04), such that moderate to heavy activity was protective against ischemic stroke in men (adjusted HR 0.37, 95% CI 0.18–0.78), but not in women (adjusted HR 0.92, 95% CI 0.57–1.50). Conclusions: Moderate- to heavy-intensity physical activity, but not energy expended, is protective against risk of ischemic stroke independent of other stroke risk factors in men in our cohort. Engaging in moderate to heavy physical activities may be an important component of primary prevention strategies aimed at reducing stroke risk. GLOSSARY CI = confidence interval; HR = hazard ratio; MET = metabolic equivalents. PMID:19933979

  1. Optimizing parameter of particle damping based on Leidenfrost effect of particle flows

    NASA Astrophysics Data System (ADS)

    Lei, Xiaofei; Wu, Chengjun; Chen, Peng

    2018-05-01

    Particle damping (PD) has strongly nonlinearity. With sufficiently vigorous vibration conditions, it always plays excellent damping performance and the particles which are filled into cavity are on Leidenfrost state considered in particle flow theory. For investigating the interesting phenomenon, the damping effect of PD on this state is discussed by the developed numerical model which is established based on principle of gas and solid. Furtherly, the numerical model is reformed and applied to study the relationship of Leidenfrost velocity with characteristic parameters of PD such as particle density, diameter, mass packing ratio and diameter-length ratio. The results indicate that particle density and mass packing ratio can drastically improve the damping performance as opposed as particle diameter and diameter-length ratio, mass packing ratio and diameter-length ratio can low the excited intensity for Leidenfrost state. For discussing the application of the phenomenon in engineering, bound optimization by quadratic approximation (BOBYQA) method is employed to optimize mass packing ratio of PD for minimize maximum amplitude (MMA) and minimize total vibration level (MTVL). It is noted that the particle damping can drastically reduce the vibrating amplitude for MMA as Leidenfrost velocity equal to the vibrating velocity relative to maximum vibration amplitude. For MTVL, larger mass packing ratio is best option because particles at relatively wide frequency range is adjacent to Leidenfrost state.

  2. The role of MR imaging in detection of hepatic iron overload in patients with cirrhosis of different origins.

    PubMed

    Szurowska, Edyta; Sikorska, Katarzyna; Izycka-Swieszewska, E; Nowicki, Tomasz; Romanowski, Tomasz; Bielawski, Krzysztof P; Studniarek, Michał

    2010-01-27

    There are many pathological conditions with hepatic iron overload. Classical definite diagnostic methods of these disorders are invasive and based on a direct tissue biopsy material. For the last years the role of MR imaging in liver diagnostics has been increasing. MRI shows changes of liver intensity in patients with hepatic iron overload. Changes in MR signal are an indirect consequence of change of relaxation times T2 and T2*, that can be directly measured. The purpose of the study was to evaluate usefulness of MR imaging in the detection of hepatic iron overload in patients with cirrhosis of different origins. MR imaging at 1.5T was prospectively performed in 44 patients with liver cirrhosis who had undergone liver biopsy with histopathological assessment of hepatic iron deposits. In all patients the following sequences were used: SE, Express, GRE in T2 and T1-weighted images. Signal intensity (SI) was measured on images obtained with each T2 weighted sequence by means of regions of interest, placed in the liver and paraspinal muscles. The correlation between iron overload, histopathological score, serum ferritin and SI ratio was analyzed. In 20 patients with iron overload confirmed by the biopsy, the liver parenchyma demonstrated lower signal intensity than that of paraspinal muscles. This effect was visible only in 8 patients with hepatic iron overload in Express T2-weighted images. Higher signal intensity of liver than that of skeletal muscles on GRE - T2 weighted images was noted in 24 patients with cirrhosis and without elevated hepatic iron concentration. We observed a correlation between low and high iron concentration and liver to muscle SI ratio. MR imaging is a useful and fast noninvasive diagnostic tool for the detection of liver iron overload in patients with cirrhosis of different origins.Liver to muscle SI ratio in GRE-T2-weighted sequence facilitates to differentiate patients with low and high degree of hepatic iron overload, which correlates with the origin of liver cirrhosis.

  3. Application of plasma gas modulation technique for improvement of the measurement of Mn emission intensity in ICP-AES.

    PubMed

    Kubota, K; Wagatsuma, K

    2001-01-02

    A phase-sensitive detection technique associated with a digital lock-in amplifier was applied for an improvement of the detection in ICP-AES. The lock-in amplifier works as an extremely narrow band pass filter. It can pick up the modulated signal, which has the same frequency as the reference signal, from any noise and thus it can improve the signal-to-noise ratio. Modulation of the ICP can be performed by mixing small amounts of air to argon as the outer gas cyclically, because the emission intensities of ionic lines are enhanced by using the mixed gas. An electromagnetic valve, which is placed in the outer-gas flow path, causes periodic variation in the air gas in the outer-gas flow, and thus switching the valve on/off can modulate the ICP. By choosing the appropriate conditions, the addition of air gas enhances the emission intensity of ionic lines more than that of the background, thus leading to improved signal-to-background ratios. At the same time the lock-in amplifier further enhances the ionic emissions because it picks up only the modulated part of the signal. By applying the plasma gas flow modulation technique the detection and the determination limits of the Mn II 257.610 nm line are improved in comparison with the conventional method. A change in plasma shape corresponding to the modulation frequency is observed when the ICP is modulated.

  4. In-cylinder flows of a motored four-stroke engine with flat-crown and slightly concave-crown pistons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, R.F.; Yang, H.S.; Yeh, C.-N.

    2008-04-15

    The temporal and spatial evolution processes of the in-cylinder flow structures and turbulence intensities in the symmetry and offset planes of a motored four-valve, four-stroke engine during the intake and compression strokes are diagnosed by using a particle image velocimeter. Two pistons of different crown shapes (flat-crown and slightly concave-crown pistons) are studied. The inception, establishment, and evolution of the tumbling vortical flow structures during the intake and compression strokes are clearly depicted. Quantitative strengths of the rotating vortical flow motions are presented by a dimensionless parameter, the tumble ratio, which can represent the mean angular velocity of the vorticesmore » in the target plane. The turbulence intensity of the in-cylinder flow is also calculated by using the measured time-varying velocity data. The results show that the flat-crown piston induces higher bulk-averaged tumble ratio and turbulence intensity than the slightly concave-crown piston does because the tumble ratio and turbulence generated by the flat-crown piston in the offset planes during the compression stroke are particularly large. The engine with the flat-crown piston also presents larger torque and power outputs and lower hydrocarbon emission than that with the slightly concave-crown piston. This might be caused by the enhanced combustion in the engine cylinder due to the stronger tumble ratio and turbulence intensity. (author)« less

  5. Determination of nitrogen monoxide in high purity nitrogen gas with an atmospheric pressure ionization mass spectrometer

    NASA Technical Reports Server (NTRS)

    Kato, K.

    1985-01-01

    An atmospheric pressure ionization mass spectrometric (API-MS) method was studied for the determination of residual NO in high purity N2 gas. The API-MS is very sensitive to NO, but the presence of O2 interferes with the NO measurement. Nitrogen gas in cylinders as sample gas was mixed with NO standard gas and/or O2 standard gas, and then introduced into the API-MS. The calibration curves of NO and O2 has linearity in the region of 0 - 2 ppm, but the slopes changed with every cylinder. The effect of O2 on NO+ peak was additive and proportional to O2 concentration in the range of 0 - 0.5 ppm. The increase in NO+ intensity due to O2 was (0.07 - 0.13)%/O2, 1 ppm. Determination of NO and O2 was carried out by the standard addition method to eliminate the influence of variation of slopes. The interference due to O2 was estimated from the product of the O2 concentration and the ratio of slope A to Slope B. Slope A is the change in the NO+ intensity with the O2 concentration. Slope B is the intensity with O2 concentration.

  6. Quantitative imaging and in situ concentration measurements of quantum dot nanomaterials in variably saturated porous media

    DOE PAGES

    Uyuşur, Burcu; Snee, Preston T.; Li, Chunyan; ...

    2016-01-01

    Knowledge of the fate and transport of nanoparticles in the subsurface environment is limited, as techniques to monitor and visualize the transport and distribution of nanoparticles in porous media and measure their in situ concentrations are lacking. To address these issues, we have developed a light transmission and fluorescence method to visualize and measure in situ concentrations of quantum dot (QD) nanoparticles in variably saturated environments. Calibration cells filled with sand as porous medium and various known water saturation levels and QD concentrations were prepared. By measuring the intensity of the light transmitted through porous media exposed to fluorescent lightmore » and by measuring the hue of the light emitted by the QDs under UV light exposure, we obtained simultaneously in situ measurements of water saturation and QD nanoparticle concentrations with high spatial and temporal resolutions. Water saturation was directly proportional to the light intensity. A linear relationship was observed between hue-intensity ratio values and QD concentrations for constant water saturation levels. Lastly, the advantages and limitations of the light transmission and fluorescence method as well as its implications for visualizing and measuring in situ concentrations of QDs nanoparticles in the subsurface environment are discussed.« less

  7. Recollision induced excitation-ionization with counter-rotating two-color circularly polarized laser field

    NASA Astrophysics Data System (ADS)

    Ben, Shuai; Guo, Pei-Ying; Pan, Xue-Fei; Xu, Tong-Tong; Song, Kai-Li; Liu, Xue-Shen

    2017-07-01

    Nonsequential double ionization of Ar by a counter-rotating two-color circularly polarized laser field is theoretically investigated. At the combined intensity in the "knee" structure range, the double ionization occurs mainly through recollision induced excitation followed by subsequent ionization of Ar+∗ . By tracing the history of the recollision trajectories, we explain how the relative intensity ratio of the two colors controls the correlated electron dynamics and optimizes the ionization yields. The major channels contributing to enhancing the double ionization are through the elliptical trajectories with smaller travel time but not through the triangle shape or the other long cycle trajectories. Furthermore, the correlated electron dynamics could be limited to the attosecond time scale by adjusting the relative intensity ratio. Finally, the double ionization from doubly excited complex at low laser intensity is qualitatively discussed.

  8. Spatiotemporal Analysis of Coronal Loops Using Seismology of Damped Kink Oscillations and Forward Modeling of EUV Intensity Profiles

    NASA Astrophysics Data System (ADS)

    Pascoe, D. J.; Anfinogentov, S. A.; Goddard, C. R.; Nakariakov, V. M.

    2018-06-01

    The shape of the damping profile of kink oscillations in coronal loops has recently allowed the transverse density profile of the loop to be estimated. This requires accurate measurement of the damping profile that can distinguish the Gaussian and exponential damping regimes, otherwise there are more unknowns than observables. Forward modeling of the transverse intensity profile may also be used to estimate the width of the inhomogeneous layer of a loop, providing an independent estimate of one of these unknowns. We analyze an oscillating loop for which the seismological determination of the transverse structure is inconclusive except when supplemented by additional spatial information from the transverse intensity profile. Our temporal analysis describes the motion of a coronal loop as a kink oscillation damped by resonant absorption, and our spatial analysis is based on forward modeling the transverse EUV intensity profile of the loop under the isothermal and optically thin approximations. We use Bayesian analysis and Markov chain Monte Carlo sampling to apply our spatial and temporal models both individually and simultaneously to our data and compare the results with numerical simulations. Combining the two methods allows both the inhomogeneous layer width and density contrast to be calculated, which is not possible for the same data when each method is applied individually. We demonstrate that the assumption of an exponential damping profile leads to a significantly larger error in the inferred density contrast ratio compared with a Gaussian damping profile.

  9. Evaluation and optimization of the optical performance of low-concentrating dielectric compound parabolic concentrator using ray-tracing methods.

    PubMed

    Sarmah, Nabin; Richards, Bryce S; Mallick, Tapas K

    2011-07-01

    We present a detailed design concept and optical performance evaluation of stationary dielectric asymmetric compound parabolic concentrators (DiACPCs) using ray-tracing methods. Three DiACPC designs, DiACPC-55, DiACPC-66, and DiACPC-77, of acceptance half-angles (0° and 55°), (0° and 66°), and (0° and 77°), respectively, are designed in order to optimize the concentrator for building façade photovoltaic applications in northern latitudes (>55 °N). The dielectric concentrator profiles have been realized via truncation of the complete compound parabolic concentrator profiles to achieve a geometric concentration ratio of 2.82. Ray-tracing simulation results show that all rays entering the designed concentrators within the acceptance half-angle range can be collected without escaping from the parabolic sides and aperture. The maximum optical efficiency of the designed concentrators is found to be 83%, which tends to decrease with the increase in incidence angle. The intensity is found to be distributed at the receiver (solar cell) area in an inhomogeneous pattern for a wide range of incident angles of direct solar irradiance with high-intensity peaks at certain points of the receiver. However, peaks become more intense for the irradiation incident close to the extreme acceptance angles, shifting the peaks to the edge of the receiver. Energy flux distribution at the receiver for diffuse radiation is found to be homogeneous within ±12% with an average intensity of 520 W/m².

  10. A Comparison of Alternating Current and Direct Current Electrospray Ionization for Mass Spectrometry

    PubMed Central

    Sarver, Scott A.; Gartner, Carlos A.; Chetwani, Nishant; Go, David B.; Dovichi, Norman J.

    2014-01-01

    A series of studies comparing the performance of alternating current electrospray ionization (AC ESI) mass spectrometry (MS) and direct current electrospray ionization (DC ESI) MS has been conducted, exploring the absolute signal intensity and signal-to-background ratios produced by both methods using caffeine and a model peptide as targets. Because the high-voltage AC signal was more susceptible to generating gas discharges, the operating voltage range of AC ESI was significantly smaller than that for DC ESI, such that the absolute signal intensities produced by DC ESI at peak voltages were 1 - 2 orders of magnitude greater than those for AC ESI. Using an electronegative nebulizing gas, sulfur hexafluoride (SF6), instead of nitrogen (N2) increased the operating range of AC ESI by ~50%, but did not appreciably improve signal intensities. While DC ESI generated far greater signal intensities, both ionization methods produced comparable signal-to-background noise, with AC ESI spectra appearing qualitatively cleaner. A quantitative calibration analysis was performed for two analytes, caffeine and the peptide MRFA. AC ESI utilizing SF6 outperforms all other techniques for the detection of MRFA, producing chromatographic limits of detection nearly one order of magnitude lower than that of DC ESI utilizing N2, and one half that of DC ESI utilizing SF6. However, DC ESI outperforms AC ESI for the analysis of caffeine, indicating improvements in spectral quality may benefit certain compounds, or classes of compounds, on an individual basis. PMID:24464359

  11. [Application of single-band brightness variance ratio to the interference dissociation of cloud for satellite data].

    PubMed

    Qu, Wei-ping; Liu, Wen-qing; Liu, Jian-guo; Lu, Yi-huai; Zhu, Jun; Qin, Min; Liu, Cheng

    2006-11-01

    In satellite remote-sensing detection, cloud as an interference plays a negative role in data retrieval. How to discern the cloud fields with high fidelity thus comes as a need to the following research. A new method rooting in atmospheric radiation characteristics of cloud layer, in the present paper, presents a sort of solution where single-band brightness variance ratio is used to detect the relative intensity of cloud clutter so as to delineate cloud field rapidly and exactly, and the formulae of brightness variance ratio of satellite image, image reflectance variance ratio, and brightness temperature variance ratio of thermal infrared image are also given to enable cloud elimination to produce data free from cloud interference. According to the variance of the penetrating capability for different spectra bands, an objective evaluation is done on cloud penetration of them with the factors that influence penetration effect. Finally, a multi-band data fusion task is completed using the image data of infrared penetration from cirrus nothus. Image data reconstruction is of good quality and exactitude to show the real data of visible band covered by cloud fields. Statistics indicates the consistency of waveband relativity with image data after the data fusion.

  12. Cost-effective single-step carbon nanotube synthesis using microwave oven

    NASA Astrophysics Data System (ADS)

    Algadri, Natheer A.; Ibrahim, K.; Hassan, Z.; Bououdina, M.

    2017-08-01

    This paper reports the characterization of carbon nanotubes (CNTs) synthesised using a conventional microwave oven method, offering several advantages including fast, simple, low cost, and solvent free growth process. The procedure involves flattening of graphite/ferrocene mixture catalyst inside the microwave oven under ambient conditions for a very short duration of 5 s, which inhibits the loss factor of graphite and ferrocene. The effect of graphite/ferrocene mixture ratio for the synthesis of CNTs is investigated by transmission electron microscopy (TEM), field emission scanning electron microscopy (FESEM), x-ray diffraction (XRD), Raman spectroscopy and UV-NIR-Vis measurements. The samples produced using the different ratios contain nanotubes with an average diameter in the range 44-79 nm. The highest yield of CNTs is attained with graphite/ferrocene mixture ratio of 70:30. The lowest I D/I G ratio intensity as identified by Raman spectroscopy for 70:30 ratio indicates the improved crystallinity of CNTs. Due to the capillary effect of CNTs, Fe nanoparticles are found to be encapsulated inside the tubes at different positions along the tube length. The obtained results showed that the smaller the diameter of graphite and ferrocene favors the synthesis of graphene oxide upon microwave radiation.

  13. Shortened Mean Transit Time in CT Perfusion With Singular Value Decomposition Analysis in Acute Cerebral Infarction: Quantitative Evaluation and Comparison With Various CT Perfusion Parameters.

    PubMed

    Murayama, Kazuhiro; Katada, Kazuhiro; Hayakawa, Motoharu; Toyama, Hiroshi

    We aimed to clarify the cause of shortened mean transit time (MTT) in acute ischemic cerebrovascular disease and examined its relationship with reperfusion. Twenty-three patients with acute ischemic cerebrovascular disease underwent whole-brain computed tomography perfusion (CTP). The maximum MTT (MTTmax), minimum MTT (MTTmin), ratio of maximum and minimum MTT (MTTmin/max), and minimum cerebral blood volume (CBV) (CBVmin) were measured by automatic region of interest analysis. Diffusion weighted image was performed to calculate infarction volume. We compared these CTP parameters between reperfusion and nonreperfusion groups and calculated correlation coefficients between the infarction core volume and CTP parameters. Significant differences were observed between reperfusion and nonreperfusion groups (MTTmin/max: P = 0.014; CBVmin ratio: P = 0.038). Regression analysis of CTP and high-intensity volume on diffusion weighted image showed negative correlation (CBVmin ratio: r = -0.41; MTTmin/max: r = -0.30; MTTmin ratio: r = -0.27). A region of shortened MTT indicated obstructed blood flow, which was attributed to the singular value decomposition method error.

  14. Male-biased sex ratio does not promote increased sperm competitiveness in the seed beetle, Callosobruchus maculatus.

    PubMed

    McNamara, Kathryn B; Robinson, Stephen P; Rosa, Márta E; Sloan, Nadia S; van Lieshout, Emile; Simmons, Leigh W

    2016-06-16

    Sperm competition risk and intensity can select for adaptations that increase male fertilisation success. Evolutionary responses are examined typically by generating increased strength of sexual selection via direct manipulation of female mating rates (by enforcing monandry or polyandry) or by alteration of adult sex ratios. Despite being a model species for sexual selection research, the effect of sexual selection intensity via adult sex-ratio manipulation on male investment strategies has not been investigated in the seed beetle, Callosobruchus maculatus. We imposed 32 generations of experimental evolution on 10 populations of beetles by manipulating adult sex ratio. Contrary to predictions, males evolving in male-biased populations did not increase their testes and accessory gland size. This absence of divergence in ejaculate investment was also reflected in the fact that males from male-biased populations were not more successful in either preventing females from remating, or in competing directly for fertilisations. These populations already demonstrate divergence in mating behaviour and immunity, suggesting sufficient generations have passed to allow divergence in physiological and behavioural traits. We propose several explanations for the absence of divergence in sperm competitiveness among our populations and the pitfalls of using sex ratio manipulation to assess evolutionary responses to sexual selection intensity.

  15. Male-biased sex ratio does not promote increased sperm competitiveness in the seed beetle, Callosobruchus maculatus

    PubMed Central

    McNamara, Kathryn B.; Robinson, Stephen P.; Rosa, Márta E.; Sloan, Nadia S.; van Lieshout, Emile; Simmons, Leigh W.

    2016-01-01

    Sperm competition risk and intensity can select for adaptations that increase male fertilisation success. Evolutionary responses are examined typically by generating increased strength of sexual selection via direct manipulation of female mating rates (by enforcing monandry or polyandry) or by alteration of adult sex ratios. Despite being a model species for sexual selection research, the effect of sexual selection intensity via adult sex-ratio manipulation on male investment strategies has not been investigated in the seed beetle, Callosobruchus maculatus. We imposed 32 generations of experimental evolution on 10 populations of beetles by manipulating adult sex ratio. Contrary to predictions, males evolving in male-biased populations did not increase their testes and accessory gland size. This absence of divergence in ejaculate investment was also reflected in the fact that males from male-biased populations were not more successful in either preventing females from remating, or in competing directly for fertilisations. These populations already demonstrate divergence in mating behaviour and immunity, suggesting sufficient generations have passed to allow divergence in physiological and behavioural traits. We propose several explanations for the absence of divergence in sperm competitiveness among our populations and the pitfalls of using sex ratio manipulation to assess evolutionary responses to sexual selection intensity. PMID:27306351

  16. Factors associated with maternal death in an intensive care unit

    PubMed Central

    Saintrain, Suzanne Vieira; de Oliveira, Juliana Gomes Ramalho; Saintrain, Maria Vieira de Lima; Bruno, Zenilda Vieira; Borges, Juliana Lima Nogueira; Daher, Elizabeth De Francesco; da Silva Jr, Geraldo Bezerra

    2016-01-01

    Objective To identify factors associated with maternal death in patients admitted to an intensive care unit. Methods A cross-sectional study was conducted in a maternal intensive care unit. All medical records of patients admitted from January 2012 to December 2014 were reviewed. Pregnant and puerperal women were included; those with diagnoses of hydatidiform mole, ectopic pregnancy, or anembryonic pregnancy were excluded, as were patients admitted for non-obstetrical reasons. Death and hospital discharge were the outcomes subjected to comparative analysis. Results A total of 373 patients aged 13 to 45 years were included. The causes for admission to the intensive care unit were hypertensive disorders of pregnancy, followed by heart disease, respiratory failure, and sepsis; complications included acute kidney injury (24.1%), hypotension (15.5%), bleeding (10.2%), and sepsis (6.7%). A total of 28 patients died (7.5%). Causes of death were hemorrhagic shock, multiple organ failure, respiratory failure, and sepsis. The independent risk factors associated with death were acute kidney injury (odds ratio [OR] = 6.77), hypotension (OR = 15.08), and respiratory failure (OR = 3.65). Conclusion The frequency of deaths was low. Acute kidney injury, hypotension, and respiratory insufficiency were independent risk factors for maternal death. PMID:28099637

  17. Spectrofluorimetric method for the determination of sulpiride in pharmaceutical preparations and human plasma through derivatization with 2-cyanoacetamide.

    PubMed

    Shah, Jasmin; Jan, M Rasul; Khan, M Naeem; Shah, Sultan

    2013-01-01

    A sensitive and accurate spectrofluorimetric method has been developed for the determination of sulpiride in pharmaceutical preparations and human plasma. The developed method is based on the derivatization reaction of 2-cyanoacetamide with sulpiride in 30% ammonical solution. The fluorescent derivatized reaction product exhibited maximum fluorescence intensity at 379 nm after excitation at 330 nm. The optimum conditions for derivatization reactions were studied and the fluorescence intensity versus concentration plot was found to be linear over the concentration range 0.2-20.0 µg/mL with a correlation coefficient of 0.9985. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.82 and 2.73 ng/mL, respectively. The proposed method was validated according to ICH guidelines. The effects of common excipients and co-administered drugs were also studied. The accuracy of the method was checked using the standard addition method and percent recoveries were found to be in the range of 99.00-101.25% for pharmaceutical preparations and 97.00-97.80% for spiked human plasma. The method was successfully applied to commercial formulations and the results obtained for the proposed method were compared with a high-performance liquid chromatography reference method and statistically evaluated using the Student's t-test for accuracy and the variance ratio F-test for precision. A reaction pathway was also proposed. Copyright © 2012 John Wiley & Sons, Ltd.

  18. Physiological Responses and Performance Analysis Difference between Official and Simulated Karate Combat Conditions

    PubMed Central

    Chaabène, Helmi; Mkaouer, Bessem; Franchini, Emerson; Souissi, Nafaa; Selmi, Mohamed Amine; Nagra, Yassine; Chamari, Karim

    2013-01-01

    Purpose This study aimed to compare physiological responses and time-motion analysis between official and simulated karate combat. Methods Ten high-level karatekas participated in this study, which included official and simulated karate combat. Results Karatekas used more upper-limb attack techniques during official combat compared to simulated ones (6±3 vs 3±1; P=0.05, respectively). For official and simulated karate matches, the numbers of high-intensity actions (i.e. offensive and defensive fighting activity) were 14±6 and 18±5, respectively (P>0.05), lasting from <1s to 5s each. Total fighting activity phase was lower during official compared to simulated matches (21.0±8.2s vs 30.4±9.9s, P<0.01, respectively). Effort (10.0±2.8s) to rest (11.9±2.7s) ratio (E:R) was 1:1 and high-intensity actions (1.6±0.3s) to rest (11.9±2.7s) ratio was higher than 1:7 during simulated combat. During official karate match, the activity and rest duration were 10.0±3.4s and 16.2±4.1s, respectively (E:R ratio 1:1.5), while high-intensity actions were 1.5±0.3s, resulting in an E:R ratio of 1:11. Blood lactate concentration was higher during official (11.14±1.82 mmol.l-1) compared to simulated karate combat (7.80±2.66 mmol.l-1) (P<0.05). Subjective perceived exertion differed significantly between official and simulated combat (14±2 vs. 12±2; P<0.05, respectively). The majority of karatekas’ perceived exertion was higher in the lower limb muscle groups irrespective of the karate combat condition. Conclusion Official and simulated matches differ considerably, therefore coaches should create new strategies during training sessions to achieve the same effort and pause profile of competitive matches and/or that athletes should be submitted to frequent competitions to adapt themselves to the profile of this event. PMID:24868428

  19. Flow and Pollutant Transport in Urban Street Canyons of Different Aspect Ratios with Ground Heating: Large-Eddy Simulation

    NASA Astrophysics Data System (ADS)

    Li, Xian-Xiang; Britter, Rex E.; Norford, Leslie K.; Koh, Tieh-Yong; Entekhabi, Dara

    2012-02-01

    A validated large-eddy simulation model was employed to study the effect of the aspect ratio and ground heating on the flow and pollutant dispersion in urban street canyons. Three ground-heating intensities (neutral, weak and strong) were imposed in street canyons of aspect ratio 1, 2, and 0.5. The detailed patterns of flow, turbulence, temperature and pollutant transport were analyzed and compared. Significant changes of flow and scalar patterns were caused by ground heating in the street canyon of aspect ratio 2 and 0.5, while only the street canyon of aspect ratio 0.5 showed a change in flow regime (from wake interference flow to skimming flow). The street canyon of aspect ratio 1 does not show any significant change in the flow field. Ground heating generated strong mixing of heat and pollutant; the normalized temperature inside street canyons was approximately spatially uniform and somewhat insensitive to the aspect ratio and heating intensity. This study helps elucidate the combined effects of urban geometry and thermal stratification on the urban canyon flow and pollutant dispersion.

  20. Uterine Fibroids: Correlation of T2 Signal Intensity with Semiquantitative Perfusion MR Parameters in Patients Screened for MR-guided High-Intensity Focused Ultrasound Ablation.

    PubMed

    Kim, Young-Sun; Lee, Jeong-Won; Choi, Chel Hun; Kim, Byoung-Gie; Bae, Duk-Soo; Rhim, Hyunchul; Lim, Hyo Keun

    2016-03-01

    To evaluate the relationships between T2 signal intensity and semiquantitative perfusion magnetic resonance (MR) parameters of uterine fibroids in patients who were screened for MR-guided high-intensity focused ultrasound (HIFU) ablation. Institutional review board approval was granted, and informed consents were waived. One hundred seventy most symptom-relevant, nondegenerated uterine fibroids (mean diameter, 7.3 cm; range, 3.0-17.2 cm) in 170 women (mean age, 43.5 years; range, 24-56 years) undergoing screening MR examinations for MR-guided HIFU ablation from October 2009 to April 2014 were retrospectively analyzed. Fibroid signal intensity was assessed as the ratio of the fibroid T2 signal intensity to that of skeletal muscle. Parameters of semiquantitative perfusion MR imaging obtained during screening MR examination (peak enhancement, percentage of relative peak enhancement, time to peak [in seconds], wash-in rate [per seconds], and washout rate [per seconds]) were investigated to assess their relationships with T2 signal ratio by using multiple linear regression analysis. Correlations between T2 signal intensity and independently significant perfusion parameters were then evaluated according to fibroid type by using Spearman correlation test. Multiple linear regression analysis revealed that relative peak enhancement showed an independently significant correlation with T2 signal ratio (Β = 0.004, P < .001). Submucosal intracavitary (n = 20, ρ = 0.275, P = .240) and type III (n = 18, ρ = 0.082, P = .748) fibroids failed to show significant correlations between perfusion and T2 signal intensity, while significant correlations were found for all other fibroid types (ρ = 0.411-0.629, P < .05). In possible candidates for MR-guided HIFU ablation, the T2 signal intensity of nondegenerated uterine fibroids showed an independently significant positive correlation with relative peak enhancement in most cases, except those of submucosal intracavitary or type III fibroids.

  1. Primary particle diameter differentiation and bimodality identification by five analytical methods using gold nanoparticle size distributions synthesized by pulsed laser ablation in liquids

    NASA Astrophysics Data System (ADS)

    Letzel, Alexander; Gökce, Bilal; Menzel, Andreas; Plech, Anton; Barcikowski, Stephan

    2018-03-01

    For a known material, the size distribution of a nanoparticle colloid is a crucial parameter that defines its properties. However, measured size distributions are not easy to interpret as one has to consider weighting (e.g. by light absorption, scattering intensity, volume, surface, number) and the way size information was gained. The radius of a suspended nanoparticle can be given as e.g. sphere equivalent, hydrodynamic, Feret or radius of gyration. In this study, gold nanoparticles in water are synthesized by pulsed-laser ablation (LAL) and fragmentation (LFL) in liquids and characterized by various techniques (scanning transmission electron microscopy (STEM), small-angle X-ray scattering (SAXS), analytical disc centrifugation (ADC), dynamic light scattering (DLS) and UV-vis spectroscopy with Mie-Gans Theory) to study the comparability of different analytical techniques and determine the method that is preferable for a given task related to laser-generated nanoparticles. In particular, laser-generated colloids are known to be bimodal and/or polydisperse, but bimodality is sometimes not analytically resolved in literature. In addition, frequently reported small size shifts of the primary particle mode around 10 nm needs evaluation of its statistical significance related to the analytical method. Closely related to earlier studies on SAXS, different colloids in defined proportions are mixed and their size as a function of the nominal mixing ratio is analyzed. It is found that the derived particle size is independent of the nominal mixing ratio if the colloid size fractions do not overlap considerably. Conversely, the obtained size for colloids with overlapping size fractions strongly depends on the nominal mixing ratio since most methods cannot distinguish between such fractions. Overall, SAXS and ADC are very accurate methods for particle size analysis. Further, the ability of different methods to determine the nominal mixing ratio of sizes fractions is studied experimentally.

  2. Simulations of iron K pre-edge X-ray absorption spectra using the restricted active space method.

    PubMed

    Guo, Meiyuan; Sørensen, Lasse Kragh; Delcey, Mickaël G; Pinjari, Rahul V; Lundberg, Marcus

    2016-01-28

    The intensities and relative energies of metal K pre-edge features are sensitive to both geometric and electronic structures. With the possibility to collect high-resolution spectral data it is important to find theoretical methods that include all important spectral effects: ligand-field splitting, multiplet structures, 3d-4p orbital hybridization, and charge-transfer excitations. Here the restricted active space (RAS) method is used for the first time to calculate metal K pre-edge spectra of open-shell systems, and its performance is tested against on six iron complexes: [FeCl6](n-), [FeCl4](n-), and [Fe(CN)6](n-) in ferrous and ferric oxidation states. The method gives good descriptions of the spectral shapes for all six systems. The mean absolute deviation for the relative energies of different peaks is only 0.1 eV. For the two systems that lack centrosymmetry [FeCl4](2-/1-), the ratios between dipole and quadrupole intensity contributions are reproduced with an error of 10%, which leads to good descriptions of the integrated pre-edge intensities. To gain further chemical insight, the origins of the pre-edge features have been analyzed with a chemically intuitive molecular orbital picture that serves as a bridge between the spectra and the electronic structures. The pre-edges contain information about both ligand-field strengths and orbital covalencies, which can be understood by analyzing the RAS wavefunction. The RAS method can thus be used to predict and rationalize the effects of changes in both the oxidation state and ligand environment in a number of hard X-ray studies of small and medium-sized molecular systems.

  3. Method for accurate determination of dissociation constants of optical ratiometric systems: chemical probes, genetically encoded sensors, and interacting molecules.

    PubMed

    Pomorski, Adam; Kochańczyk, Tomasz; Miłoch, Anna; Krężel, Artur

    2013-12-03

    Ratiometric chemical probes and genetically encoded sensors are of high interest for both analytical chemists and molecular biologists. Their high sensitivity toward the target ligand and ability to obtain quantitative results without a known sensor concentration have made them a very useful tool in both in vitro and in vivo assays. Although ratiometric sensors are widely used in many applications, their successful and accurate usage depends on how they are characterized in terms of sensing target molecules. The most important feature of probes and sensors besides their optical parameters is an affinity constant toward analyzed molecules. The literature shows that different analytical approaches are used to determine the stability constants, with the ratio approach being most popular. However, oversimplification and lack of attention to detail results in inaccurate determination of stability constants, which in turn affects the results obtained using these sensors. Here, we present a new method where ratio signal is calibrated for borderline values of intensities of both wavelengths, instead of borderline ratio values that generate errors in many studies. At the same time, the equation takes into account the cooperativity factor or fluorescence artifacts and therefore can be used to characterize systems with various stoichiometries and experimental conditions. Accurate determination of stability constants is demonstrated utilizing four known optical ratiometric probes and sensors, together with a discussion regarding other, currently used methods.

  4. H + O3 Fourier-transform infrared emission and laser absorption studies of OH(X2Pi) radical - An experimental dipole moment function and state-to-state Einstein A coefficients

    NASA Technical Reports Server (NTRS)

    Nelson, David D., Jr.; Schiffman, Aram; Nesbitt, David J.; Orlando, John J.; Burkholder, James B.

    1990-01-01

    FTIR emission/absorption spectroscopy is used to measure the relative intensities of 88 pairs of rovibrational transitions of OH(X2Pi) distributed over 16 vibrational bands. The experimental technique used to obtain the Einstein A ratios is discussed. The dipole moment function which follows from the intensity ratios along with Einstein A coefficients calculated from mu(r) is presented.

  5. Influence of water content on the laser-induced breakdown spectroscopy analysis of human cell pellet

    NASA Astrophysics Data System (ADS)

    Moon, Youngmin; Han, Jung Hyun; Lee, Jong Jin; Jeong, Sungho

    2015-12-01

    The effects of water content change in a biological sample on the emission signal intensity and intensity ratio during LIBS analysis were investigated. To examine the effects of water content only avoiding matrix effects, a homogeneous human cell pellet consisting of cultured human immortalized keratinocyte cell only was used as the sample. LIBS spectra of the human cell pellet sample produced with a Q-switched Nd:YAG laser (λ = 532 nm, τ = 5 ns, top-hat profile) and a six-channel CCD spectrometer (spectral range = 187-1045 nm, spectral resolution = 0.1 nm) revealed that most of the emission lines observed from a tissue sample were also observable from the human cell pellet. The intensity and intensity ratio of the emission lines varied significantly as the water content of the human cell pellet was changed. It was found that a typically selected internal standard in LIBS analysis of biological samples such as carbon could produce inconsistent results, whereas the ratio of properly selected emission lines such as Mg(II) 280.270 nm and Ca(II) 396.847 nm was nearly independent of sample water content.

  6. The spatial variation of the infrared-to-radio ratio in spiral galaxies

    NASA Technical Reports Server (NTRS)

    Marsh, K. A.; Helou, G.

    1995-01-01

    We have produced two-dimensional maps of the intensity ratio, Q(sub 60), of 60 micron infrared to 20 cm radio continuum emission, for a set of 25 nearby galaxies, mostly spirals. The ratio maps were obtained from infrared images made using IRAS data with the maximum correlation method, and radio images made using VLA data. Before taking the ratio, the radio images were processed so as to have the same resolution properties as the infrared images; the final spatial resolution in all cases is approximately 1 min, corresponding to 1 - 2 kpc for most galaxies. This resolution represents a significant improvement over previous studies. Our new high-resolution maps confirm the slow decrease of Q(sub 60) with increasing radial distance from the nucleus, but show additional structure which is probably associated with separate sites of active star formation in the spiral arms. The maps show Q(sub 60) to be more closely related to infrared surface brightness than to the radial distance r in the galaxy disk. We note also that the Q(sub 60) gradients are absent (or at least reduced) for the edge-on galaxies, a property which can be attributed to the dilution of contrast due to the averaging of the additional structure along the line of sight. The results are all in qualitative agreement with the suggestion that the radio image represents a smeared version of the infrared image, as would be expected on the basis of current models in which the infrared-radio correlation is driven by the formation of massive stars, and the intensity distribution of radio emission is smeared as a result of the propagation of energetic electrons accelerated during the supernova phase.

  7. Taste masking of ondansetron hydrochloride by polymer carrier system and formulation of rapid-disintegrating tablets.

    PubMed

    Khan, Shagufta; Kataria, Prashant; Nakhat, Premchand; Yeole, Pramod

    2007-06-22

    The purpose of this research was to mask the intensely bitter taste of ondansetron HCl and to formulate a rapid-disintegrating tablet (RDT) of the taste-masked drug. Taste masking was done by complexing ondansetron HCl with aminoalkyl methacrylate copolymer (Eudragit EPO) in different ratios by the precipitation method. Drug-polymer complexes (DPCs) were tested for drug content, in vitro taste in simulated salivary fluid (SSF) of pH 6.2, and molecular property. Complex that did not release drug in SSF was considered taste-masked and selected for formulation RDTs. The complex with drug-polymer ratio of 8:2 did not show drug release in SSF; therefore, it was selected. The properties of tablets such as tensile strength, wetting time, water absorption ratio, in vitro disintegration time, and disintegration in the oral cavity were investigated to elucidate the wetting and disintegration characteristics of tablets. Polyplasdone XL-10 7% wt/wt gave the minimum disintegration time. Tablets of batch F4 containing spray-dried mannitol and microcrystalline cellulose in the ratio 1:1 and 7% wt/wt Polyplasdone XL-10 showed faster disintegration, within 12.5 seconds, than the marketed tablet (112 seconds). Good correlation between in vitro disintegration behavior and in the oral cavity was recognized. Taste evaluation of RDT in human volunteers revealed considerable taste masking with the degree of bitterness below threshold value (0.5) ultimately reaching to 0 within 15 minutes, whereas ondansetron HCl was rated intensely bitter with a score of 3 for 10 minutes. Tablets of batch F4 also revealed rapid drug release (t(90), 60 seconds) in SGF compared with marketed formulation (t(90), 240 seconds; P < .01). Thus, results conclusively demonstrated successful masking of taste and rapid disintegration of the formulated tablets in the oral cavity.

  8. Measurement of laser power for photo-triggered drug delivery in vivo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, R.; Zhang, X. L.; Liu, F.

    Thus far, despite many investigations have been carried out for photo-triggered drug delivery systems, most of them suffer from an intrinsic drawback of without real-time monitoring mechanism. Incident intensity of light is a feasible parameter to monitor the drug release profiles. However, it is difficult to measure the incident laser power irradiated onto the photo-triggered carriers in drug delivery systems during in vivo therapy. We design an online measurement method based on the fluorescence intensity ratio (FIR) technique through upconversion nanoparticles. FIR value varies with temperature of sample due to the thermal effect induced by the incident laser, which validatesmore » the laser power measurement. Effects of rare earth doping concentration, as well as experimental conditions including laser spots and wavelengths on the measurement behavior were also investigated.« less

  9. Ultrasound with low intensity assisted the synthesis of nanocrystalline TiO2 without calcination.

    PubMed

    Ghows, Narjes; Entezari, Mohamad H

    2010-06-01

    A novel method has been developed for the preparation of nano-sized TiO(2) with anatase phase. Nanoparticles with diameter about 6 nm were prepared at a relatively low temperature (75 degrees C) and short time. The synthesis was carried out by the hydrolysis of titanium tetra-isopropoxide (TTIP) in the presence of water, ethanol, and dispersant under ultrasonic irradiation (500 kHz) at low intensity. The results show that variables such as water/ethanol ratio, irradiation time, and temperature have a great influence on the particle size and crystalline phases of TiO(2) nanoparticles. Characterization of the product was carried out by different techniques such as powder X-ray diffraction (XRD), transmission electron microscopy (TEM), high resolution transmission electron microscopy (HRTEM) and UV-vis spectroscopy. (c) 2010 Elsevier B.V. All rights reserved.

  10. Adaptive optics for confocal laser scanning microscopy with adjustable pinhole

    NASA Astrophysics Data System (ADS)

    Yoo, Han Woong; van Royen, Martin E.; van Cappellen, Wiggert A.; Houtsmuller, Adriaan B.; Verhaegen, Michel; Schitter, Georg

    2016-04-01

    The pinhole plays an important role in confocal laser scanning microscopy (CLSM) for adaptive optics (AO) as well as in imaging, where the size of the pinhole denotes a trade-off between out-of-focus rejection and wavefront distortion. This contribution proposes an AO system for a commercial CLSM with an adjustable square pinhole to cope with such a trade-off. The proposed adjustable pinhole enables to calibrate the AO system and to evaluate the imaging performance. Experimental results with fluorescence beads on the coverslip and at a depth of 40 μm in the human hepatocellular carcinoma cell spheroid demonstrate that the proposed AO system can improve the image quality by the proposed calibration method. The proposed pinhole intensity ratio also indicates the image improvement by the AO correction in intensity as well as resolution.

  11. A calibration method immune to the projector errors in fringe projection profilometry

    NASA Astrophysics Data System (ADS)

    Zhang, Ruihua; Guo, Hongwei

    2017-08-01

    In fringe projection technique, system calibration is a tedious task to establish the mapping relationship between the object depths and the fringe phases. Especially, it is not easy to accurately determine the parameters of the projector in this system, which may induce errors in the measurement results. To solve this problem, this paper proposes a new calibration by using the cross-ratio invariance in the system geometry for determining the phase-to-depth relations. In it, we analyze the epipolar eometry of the fringe projection system. On each epipolar plane, the depth variation along an incident ray induces the pixel movement along the epipolar line on the image plane of the camera. These depth variations and pixel movements can be connected by use of the projective transformations, under which condition the cross-ratio for each of them keeps invariant. Based on this fact, we suggest measuring the depth map by use of this cross-ratio invariance. Firstly, we shift the reference board in its perpendicular direction to three positions with known depths, and measure their phase maps as the reference phase maps; and secondly, when measuring an object, we calculate the object depth at each pixel by equating the cross-ratio of the depths to that of the corresponding pixels having the same phase on the image plane of the camera. This method is immune to the errors sourced from the projector, including the distortions both in the geometric shapes and in the intensity profiles of the projected fringe patterns.The experimental results demonstrate the proposed method to be feasible and valid.

  12. 21 CFR 1050.10 - Ultrasonic therapy products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... greater than 5 percent of the spatial-maximum intensity in that plane. (4) Beam nonuniformity ratio means..., operation controls, and a cabinet to house these components. (17) Maximum beam nonuniformity ratio means the maximum value of the beam nonuniformity ratio characteristic of a model of an ultrasonic therapy product...

  13. 21 CFR 1050.10 - Ultrasonic therapy products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... greater than 5 percent of the spatial-maximum intensity in that plane. (4) Beam nonuniformity ratio means..., operation controls, and a cabinet to house these components. (17) Maximum beam nonuniformity ratio means the maximum value of the beam nonuniformity ratio characteristic of a model of an ultrasonic therapy product...

  14. 21 CFR 1050.10 - Ultrasonic therapy products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... greater than 5 percent of the spatial-maximum intensity in that plane. (4) Beam nonuniformity ratio means..., operation controls, and a cabinet to house these components. (17) Maximum beam nonuniformity ratio means the maximum value of the beam nonuniformity ratio characteristic of a model of an ultrasonic therapy product...

  15. 21 CFR 1050.10 - Ultrasonic therapy products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... greater than 5 percent of the spatial-maximum intensity in that plane. (4) Beam nonuniformity ratio means..., operation controls, and a cabinet to house these components. (17) Maximum beam nonuniformity ratio means the maximum value of the beam nonuniformity ratio characteristic of a model of an ultrasonic therapy product...

  16. 21 CFR 1050.10 - Ultrasonic therapy products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... greater than 5 percent of the spatial-maximum intensity in that plane. (4) Beam nonuniformity ratio means..., operation controls, and a cabinet to house these components. (17) Maximum beam nonuniformity ratio means the maximum value of the beam nonuniformity ratio characteristic of a model of an ultrasonic therapy product...

  17. Cardiovascular risk factors associated with the metabolic syndrome are more prevalent in people reporting chronic pain: results from a cross-sectional general population study.

    PubMed

    Goodson, Nicola J; Smith, Blair H; Hocking, Lynne J; McGilchrist, Mark M; Dominiczak, Anna F; Morris, Andrew; Porteous, David J; Goebel, Andreas

    2013-09-01

    To explore whether chronic pain is associated with cardiovascular risk factors and identify whether increased distribution or intensity of pain is associated with cardiovascular risk, participants in Generation Scotland: The Scottish Family Health study completed pain questionnaires recording the following: presence of chronic pain, distribution of pain, and intensity of chronic pain. Blood pressure, lipids, blood glucose, smoking history, waist-hip ratio, and body mass index were recorded; Framingham 10-year coronary heart disease (CHD) risk scores were calculated and a diagnosis of metabolic syndrome derived. Associations between chronic pain and cardiovascular risk were explored. Of 13,328 participants, 1100 (8.3%) had high CHD risk. Chronic pain was reported by 5209 (39%), 1294 (9.7%) reported widespread chronic pain, and 707 (5.3%) reported high-intensity chronic pain. In age- and gender-adjusted analyses, chronic pain was associated with elevated CHD risk scores (odds ratio 1.11, 95% confidence interval 1.01-1.23) and the metabolic syndrome (odds ratio 1.42, 95% confidence interval 1.24-1.62). Multivariate analyses identified dyslipidaemia, age, gender, smoking, obesity, and high waist-hip ratio as independently associated with chronic pain. Within the chronic pain subgroup, widespread pain did not confer any additional cardiovascular disease risk. However, cardiovascular disease risk factors contributing to metabolic syndrome were more prevalent in those reporting high-intensity chronic pain. This large population-based study has demonstrated that chronic pain, and in particular high-intensity chronic pain, is associated with an increased prevalence of cardiovascular risk factors and metabolic syndrome. The 10-year CHD risk score and metabolic syndrome correlate well with increased pain intensity, but not with widespread pain. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  18. Diagnostic significance of gadolinium-DTPA (diethylenetriamine penta-acetic acid) enhanced magnetic resonance imaging in thrombolytic treatment for acute myocardial infarction: its potential in assessing reperfusion.

    PubMed Central

    van der Wall, E E; van Dijkman, P R; de Roos, A; Doornbos, J; van der Laarse, A; Manger Cats, V; van Voorthuisen, A E; Matheijssen, N A; Bruschke, A V

    1990-01-01

    The diagnostic value of gadolinium-DTPA (diethylenetriamine penta-acetic acid) enhanced magnetic resonance imaging in patients treated by thrombolysis for acute myocardial infarction was assessed in 27 consecutive patients who had a first acute myocardial infarction (14 anterior, 13 inferior) and who underwent thrombolytic treatment and coronary arteriography within 4 hours of the onset of symptoms. Magnetic resonance imaging was performed 93 hours (range 15-241) after the onset of symptoms. A Philips Gyroscan (0.5 T) was used, and spin echo measurements (echo time 30 ms) were made before and 20 minutes after intravenous injection of 0.1 mmol/kg gadolinium-DTPA. In all patients contrast enhancement of the infarcted areas was seen after Gd-DTPA. The signal intensities of the infarcted and normal values were used to calculate the intensity ratios. Mean (SD) intensity ratios after Gd-DTPA were significantly increased (1.15 (0.17) v 1.52 (0.29). Intensity ratios were higher in the 17 patients who underwent magnetic resonance imaging more than 72 hours after the onset of symptoms than in the 10 who underwent magnetic resonance imaging earlier, the difference being significantly greater after administration of Gd-DTPA (1.38 (0.12) v 1.61 (0.34). When patients were classified according to the site and size of the infarcted areas, or to reperfusion (n = 19) versus non-reperfusion (n = 8), the intensity ratios both before and after Gd-DTPA did not show significant differences. Magnetic resonance imaging with Gd-DTPA improved the identification of acutely infarcted areas, but with current techniques did not identify patients in whom thrombolytic treatment was successful. Images PMID:2310640

  19. Anisotropic localized surface plasmon resonances in CuS nanoplates prepared by size-selective precipitation

    NASA Astrophysics Data System (ADS)

    Hamanaka, Yasushi; Yamada, Kaoru; Hirose, Tatsunori; Kuzuya, Toshihiro

    2018-05-01

    CuS nanoplates were synthesized by a colloidal method and separated into four fractions of nanoplates with different aspect ratios by a size-selective precipitation. In addition to a strong near infrared absorption band ascribed to the in-plane mode of the localized surface plasmon resonance (LSPR), we found a weak absorption band on the high frequency tail of the in-plane LSPR band. The frequency of the weak absorption band was almost constant and independent of the aspect ratio, while the in-plane LSPR band exhibited a strong aspect ratio dependence. These characteristics suggested that the weak absorption band is ascribed to the out-of-plane LSPR. Although the out-of-plane LSPR was expected to be difficult to observe for CuS nanoplates due to its low intensity and overlap with the strong in-plane resonance, we could successfully identify the out-of-plane mode by reducing the width of the size distribution and spectral broadening caused thereby.

  20. No sexual dimorphism in human prenatal metacarpal ratios.

    PubMed

    Van Dongen, Stefan; Galis, Frietson; Ten Broek, Clara; Heikinheimo, Kristiina; Wijnaendts, Liliane C D; Delen, Sofie; Bots, Jessica

    2014-03-01

    Ratios of digit lengths are studied intensively as markers of prenatal sex hormone levels. Study sexual dimorphism in ratios of metacarpals, which received less attention. We studied six metacarpal ratios in deceased human fetuses of ages 10 to 42weeks. We found no indication of a sexual dimorphism at this early stage of development. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Assessing the impact of lyophilization process in production of implants based on the bacterial cellulose using Raman spectroscopy method

    NASA Astrophysics Data System (ADS)

    Timchenko, E. V.; Timchenko, P. E.; Pisareva, E. V.; Vlasov, M. Yu; Revin, V. V.; Klenova, N. A.; Asadova, A. A.

    2017-01-01

    In this article we present the research results of lyophilization process influence on the composition of hybrid materials based on the bacterial cellulose (BC) using Raman spectroscopy method. As an object of research was used BC, as well as hybrids based on it, comprising the various combinations of hydroxyapatite (HAP) and collagen. Our studies showed that during the lyophilization process changes the ratio of the individual components. It was found that for samples hybrid based on BC with addition of HAP occurs increase of PO4 3- peak intensity in the region 956 cm-1 with decreasing width, which indicates a change in the degree of HAP crystallinity.

  2. Reconstruction of pulse noisy images via stochastic resonance

    PubMed Central

    Han, Jing; Liu, Hongjun; Sun, Qibing; Huang, Nan

    2015-01-01

    We investigate a practical technology for reconstructing nanosecond pulse noisy images via stochastic resonance, which is based on the modulation instability. A theoretical model of this method for optical pulse signal is built to effectively recover the pulse image. The nanosecond noise-hidden images grow at the expense of noise during the stochastic resonance process in a photorefractive medium. The properties of output images are mainly determined by the input signal-to-noise intensity ratio, the applied voltage across the medium, and the correlation length of noise background. A high cross-correlation gain is obtained by optimizing these parameters. This provides a potential method for detecting low-level or hidden pulse images in various imaging applications. PMID:26067911

  3. Practical implementation of tetrahedral mesh reconstruction in emission tomography

    PubMed Central

    Boutchko, R.; Sitek, A.; Gullberg, G. T.

    2014-01-01

    This paper presents a practical implementation of image reconstruction on tetrahedral meshes optimized for emission computed tomography with parallel beam geometry. Tetrahedral mesh built on a point cloud is a convenient image representation method, intrinsically three-dimensional and with a multi-level resolution property. Image intensities are defined at the mesh nodes and linearly interpolated inside each tetrahedron. For the given mesh geometry, the intensities can be computed directly from tomographic projections using iterative reconstruction algorithms with a system matrix calculated using an exact analytical formula. The mesh geometry is optimized for a specific patient using a two stage process. First, a noisy image is reconstructed on a finely-spaced uniform cloud. Then, the geometry of the representation is adaptively transformed through boundary-preserving node motion and elimination. Nodes are removed in constant intensity regions, merged along the boundaries, and moved in the direction of the mean local intensity gradient in order to provide higher node density in the boundary regions. Attenuation correction and detector geometric response are included in the system matrix. Once the mesh geometry is optimized, it is used to generate the final system matrix for ML-EM reconstruction of node intensities and for visualization of the reconstructed images. In dynamic PET or SPECT imaging, the system matrix generation procedure is performed using a quasi-static sinogram, generated by summing projection data from multiple time frames. This system matrix is then used to reconstruct the individual time frame projections. Performance of the new method is evaluated by reconstructing simulated projections of the NCAT phantom and the method is then applied to dynamic SPECT phantom and patient studies and to a dynamic microPET rat study. Tetrahedral mesh-based images are compared to the standard voxel-based reconstruction for both high and low signal-to-noise ratio projection datasets. The results demonstrate that the reconstructed images represented as tetrahedral meshes based on point clouds offer image quality comparable to that achievable using a standard voxel grid while allowing substantial reduction in the number of unknown intensities to be reconstructed and reducing the noise. PMID:23588373

  4. Practical implementation of tetrahedral mesh reconstruction in emission tomography

    NASA Astrophysics Data System (ADS)

    Boutchko, R.; Sitek, A.; Gullberg, G. T.

    2013-05-01

    This paper presents a practical implementation of image reconstruction on tetrahedral meshes optimized for emission computed tomography with parallel beam geometry. Tetrahedral mesh built on a point cloud is a convenient image representation method, intrinsically three-dimensional and with a multi-level resolution property. Image intensities are defined at the mesh nodes and linearly interpolated inside each tetrahedron. For the given mesh geometry, the intensities can be computed directly from tomographic projections using iterative reconstruction algorithms with a system matrix calculated using an exact analytical formula. The mesh geometry is optimized for a specific patient using a two stage process. First, a noisy image is reconstructed on a finely-spaced uniform cloud. Then, the geometry of the representation is adaptively transformed through boundary-preserving node motion and elimination. Nodes are removed in constant intensity regions, merged along the boundaries, and moved in the direction of the mean local intensity gradient in order to provide higher node density in the boundary regions. Attenuation correction and detector geometric response are included in the system matrix. Once the mesh geometry is optimized, it is used to generate the final system matrix for ML-EM reconstruction of node intensities and for visualization of the reconstructed images. In dynamic PET or SPECT imaging, the system matrix generation procedure is performed using a quasi-static sinogram, generated by summing projection data from multiple time frames. This system matrix is then used to reconstruct the individual time frame projections. Performance of the new method is evaluated by reconstructing simulated projections of the NCAT phantom and the method is then applied to dynamic SPECT phantom and patient studies and to a dynamic microPET rat study. Tetrahedral mesh-based images are compared to the standard voxel-based reconstruction for both high and low signal-to-noise ratio projection datasets. The results demonstrate that the reconstructed images represented as tetrahedral meshes based on point clouds offer image quality comparable to that achievable using a standard voxel grid while allowing substantial reduction in the number of unknown intensities to be reconstructed and reducing the noise.

  5. A narrower gap of grazing intensity. Reply to Fetzel et al. 2017. Seasonality constrains to livestock grazing intensity

    USDA-ARS?s Scientific Manuscript database

    Fetzel et al. (2017) globally mapped the gap between observed and potential grazing intensity (GI): the ratio between consumption by livestock and ANPP. Fetzel et al. (2017) estimated grazing land, forage production and livestock demand at a half-degree resolution. They mapped GI below 15% for most ...

  6. Relative L-shell X-ray intensities of Pt, Pb and Bi following ionization by 59.54 keV γ-rays

    NASA Astrophysics Data System (ADS)

    Dhal, B. B.; Padhi, H. C.

    1994-12-01

    Relative L-shell X-ray intensities of Pt, Pb and Bi have been measured following ionization by 59.54 keV photons from an 241 Am point source. The measured ratios have been compared with the theoretical ratios estimated using the photoionization cross-sections of Scofield and different decay yield data. The comparison shows good agreement for Pb and Bi with the decay yield data of Krause, but the decay yield data of Xu and Xu overestimates the ratios, particularly for the {I γ}/{I α} ratio. Our results for Pb and Bi with improved error limits also agree with the previous experimental results of Shatendra et al. For Pt our present results are found to lie between the two theoretical results obtained by using different sets of decay yield data.

  7. Comparative Study of Elemental Nutrients in Organic and Conventional Vegetables Using Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Bhatt, Chet R; Alfarraj, Bader; Ghany, Charles T; Yueh, Fang Y; Singh, Jagdish P

    2017-04-01

    In this study, the laser-induced breakdown spectroscopy (LIBS) technique was used to identify and compare the presence of major nutrient elements in organic and conventional vegetables. Different parts of cauliflowers and broccolis were used as working samples. Laser-induced breakdown spectra from these samples were acquired at optimum values of laser energy, gate delay, and gate width. Both univariate and multivariate analyses were performed for the comparison of these organic and conventional vegetable flowers. Principal component analysis (PCA) was taken into account for multivariate analysis while for univariate analysis, the intensity of selected atomic lines of different elements and their intensity ratio with some reference lines of organic cauliflower and broccoli samples were compared with those of conventional ones. In addition, different parts of the cauliflower and broccoli were compared in terms of intensity and intensity ratio of elemental lines.

  8. Testing paleointensity determinations on recent lava flows and scorias from Miyakejima, Japan

    NASA Astrophysics Data System (ADS)

    Fukuma, K.

    2013-12-01

    Still no consensus has been reached on paleointensity method. Even the classical Thellier method has not been fully tested on recent lava flows with known geomagnetic field intensity based on a systematic sampling scheme. In this study, Thellier method was applied for 1983, 1962 and 1940 basaltic lava flows and scorias from Miyakejima, Japan. Several vertical lava sections and quenched scorias, which are quite variable in magnetic mineralogy and grain size, provide an unparalleled opportunity to test paleointensity methods. Thellier experiments were conducted on a completely automated three-component spinner magnetometer with thermal demagnetizer 'tspin'. Specimens were heated in air, applied laboratory field was 45 microT, and pTRM checks were performed at every two heating steps. Curie points and hysteresis properties were obtained on small fragments removed from cylindrical specimens. For lava flows sigmoidal curves were commonly observed on the Arai diagrams. Especially the interior part of lava flows always revealed sigmoidal patterns and sometimes resulted in erroneously blurred behaviors. The directions after zero-field heating were not necessarily stable in the course of the Thellier experiments. It was very difficult, for the interior part, to ascertain linear segments on Arai diagrams corresponding to the geomagnetic field intensity at the eruption. Upper and lower clinker samples also generally revealed sigmoidal or upward concave curves on Arai diagrams. Neither lower nor higher temperature portions of the sigmoids or concaves gave the expected geomagnetic field intensities. However, there were two exceptional cases of lava flows giving correct field intensities: upper clinkers with relatively low unblocking temperatures (< 400 deg.C) and lower clinkers with broad unblocking temperature ranges from room temperature to 600 deg.C. A most promising target for paleointensity experiments within the volcanic rocks is scoria. Scoria samples always carry single Curie temperatures higher than 500 deg.C, and the ratios of saturation remanence to saturation magnetization (Mr/Ms) of about 0.5 are indicative of truly single-domain low-titanium titanomagnetite. Unambiguous straight lines were always observed on Arai diagrams covering broad temperature ranges like the lower clinker samples, and the gradients gave the expected field values within a few percent errors. Thellier experiments applied for the recent lava flows did not successfully recover the expected field intensity from most samples. No linear segment was recognized or incorrect paleointensity values were obtained from short segments with limited temperature ranges. In Thellier or other types of paleointensity experiments laboratory alteration is checked in details, but if a sample once passed the alteration check, the TRM/NRM ratios of any limited temperature or field ranges were accepted as reflecting paleointensity. Previously published paleointensity data from lava flows should include much of such dubious data. Generally lava flows are not suitable for paleointensity determinations in light of its large grain-size and mixed magnetic mineralogy, except for scoria and clinker.

  9. Synthesis route and three different core-shell impacts on magnetic characterization of gadolinium oxide-based nanoparticles as new contrast agents for molecular magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Azizian, Gholamreza; Riyahi-Alam, Nader; Haghgoo, Soheila; Moghimi, Hamid Reza; Zohdiaghdam, Reza; Rafiei, Behrooz; Gorji, Ensieh

    2012-10-01

    Despite its good resolution, magnetic resonance imaging intrinsically has low sensitivity. Recently, contrast agent nanoparticles have been used as sensitivity and contrast enhancer. The aim of this study was to investigate a new controlled synthesis method for gadolinium oxide-based nanoparticle preparation. For this purpose, diethyleneglycol coating of gadolinium oxide (Gd2O3-DEG) was performed using new supervised polyol route, and small particulate gadolinium oxide (SPGO) PEGylation was obtained with methoxy-polyethylene-glycol-silane (550 and 2,000 Da) coatings as SPGO-mPEG-silane550 and 2,000, respectively. Physicochemical characterization and magnetic properties of these three contrast agents in comparison with conventional Gd-DTPA were verified by dynamic light scattering transmission electron microscopy, Fourier transform infrared spectroscopy, inductively coupled plasma, X-ray diffraction, vibrating sample magnetometer, and the signal intensity and relaxivity measurements were performed using 1.5-T MRI scanner. As a result, the nanoparticle sizes of Gd2O3-DEG, SPGO-mPEG-silane550, and SPGO-mPEG-silane2000 could be reached to 5.9, 51.3, 194.2 nm, respectively. The image signal intensity and longitudinal ( r 1) and transverse relaxivity ( r 2) measurements in different concentrations (0.3 to approximately 2.5 mM), revealed the r 2/ r 1 ratios of 1.13, 0.89, 33.34, and 33.72 for Gd-DTPA, Gd2O3-DEG, SPGO-mPEG-silane550, and SPGO-mPEG-silane2000, respectively. The achievement of new synthesis route of Gd2O3-DEG resulted in lower r 2/ r 1 ratio for Gd2O3-DEG than Gd-DTPA and other previous synthesized methods by this and other groups. The smaller r 2/ r 1 ratios of two PEGylated-SPGO contrast agents in our study in comparison with r 2/ r 1 ratio of previous PEGylation ( r 2/ r 1 = 81.9 for mPEG-silane 6,000 MW) showed that these new three introduced contrast agents could potentially be proper contrast enhancers for cellular and molecular MR imaging.

  10. The biochemical, nanomechanical and chemometric signatures of brain cancer

    NASA Astrophysics Data System (ADS)

    Abramczyk, Halina; Imiela, Anna

    2018-01-01

    Raman spectroscopy and imaging combined with AFM topography and mechanical indentation by AFM have been shown to be an effective tool for analysis and discrimination of human brain tumors from normal structures. Raman methods have potential to be applied in clinical practice as they allow for identification of tumor margins during surgery. In this study, we investigate medulloblastoma (grade IV WHO) (n = 5) and the tissue from the negative margins used as normal controls. We compare a high grade medulloblastoma (IV grade), and non-tumor samples from human central nervous system (CNS) tissue. Based on the properties of the Raman vibrational spectra and Raman images we provide a real-time feedback that is label-free method to monitor tumor metabolism that reveals reprogramming of biosynthesis of lipids, and proteins. We have found that the high-grade tumors of central nervous system (medulloblastoma) exhibit enhanced level of β-sheet conformation and down-regulated level of α-helix conformation when comparing against normal tissue. We have shown that the ratio of Raman intensities I2930/I2845 at 2930 and 2845 cm- 1 is a good source of information on the ratio of lipid and protein contents. We have found that the ratio reflects the lipid and protein contents of tumorous brain tissue compared to the non-tumor tissue. Almost all brain tumors have the Raman intensity ratios significantly higher (1.99 ± 0.026) than that found in non-tumor brain tissue, which is 1.456 ± 0.02, and indicates that the relative amount of lipids compared to proteins is significantly higher in the normal brain tissue. Mechanical indentation using AFM on sliced human brain tissues (medulloblastoma, grade IV) revealed that the mechanical properties of this tissue are strongly heterogeneous, between 1.8 and 75.7 kPa, and the mean of 27.16 kPa. The sensitivity and specificity obtained directly from PLSDA and cross validation gives a sensitivity and specificity of 98.5% and 96% and 96.3% and 92% for cross-validation, respectively. The high sensitivity and specificity demonstrates usefulness for a proper decision for a Raman diagnostic test on biochemical alterations monitored by Raman spectroscopy related to brain cancer development.

  11. Effect of dividing daylight in symmetric prismatic daylight collector

    NASA Astrophysics Data System (ADS)

    Yeh, Shih-Chuan; Lu, Ju-Lin; Cheng, Yu-Chin

    2017-04-01

    This paper presented a symmetric prismatic daylight collector to collect daylight for the natural light illumination system. We analyzed the characteristics of the emerging light when the parallel light beam illuminate on the horizontally placed symmetric prismatic daylight collector. The ratio of the relative intensities of collected daylight that emerging from each surface of the daylight collector shown that the ratio is varied with the incident angle during a day. The simulation of the emerging light of the daylight collector shown that the ratio of emerging light is varied with the tilted angle when sunshine illuminated on a symmetric prismatic daylight collector which was not placed horizontally. The integration of normalized intensity is also varied with the tilted angle. The symmetric prismatic daylight collector with the benefits of reducing glare and dividing intensity of incident daylight, it is applicable to using in the natural light illumination system and hybrid system for improving the efficiency of utilizing of solar energy.

  12. Tune color of single-phase LiGd(MoO4)2-X(WO4)X: Sm3+, Tb3+ via adjusting the proportion of matrix and energy transfer to create white-light phosphor

    NASA Astrophysics Data System (ADS)

    Wu, Hongyue; Yang, Junfeng; Wang, Xiaoxue; Gan, Shucai; Li, Linlin

    2018-03-01

    A series of LiGd(MO4)2: Sm3+, Tb3+ (M = Mo, W) phosphors was prepared by a conventional solid state reaction method. Powder X-Ray diffraction (XRD) analysis reveals that the compounds are of the same structure type. Their luminescent properties have been studied. The optimal doping concentrations are 8% for Sm3+ and 18% for Tb3+ in the LiGd(MoO4)2 host. Sm3+ and Tb3+ have different sensitivity to the Mo/W ratio. For LiGd(MoO4)2-X(WO4)X: Sm3+ (X = 0, 0.4, 0.8, 1.2, 1.6, 2.0), the strongest emission intensity is 1.766 times than that of the weakest, while 171 times for LiGd(MoO4)2-X(WO4)X: Tb3+. The experimental results show that Mo/W ratio strong influences on the properties of LiGd(MoO4)2-X(WO4)X: Tb3+. With the increasing of WO42- groups concentration, the shape of characteristic excitation peaks of Tb3+ is almost the same and the excitation intensity gradually increase. Moreover, the energy transfer from Tb3+ to Sm3+ has been realized in the co-doped phosphors. The experimental analysis and theoretical calculations reveal that the quadrupole-quadrupole interaction is the dominant mechanism for the Tb3+→Sm3+ energy transfer. Therefore, luminous intensity can be adjusted by different sensitivities to matrix composition and energy transfer from Tb3+→Sm3+. By this tuning color method, white-light-emitting phosphor has been prepared. The excitation wavelength is 378 nm, and this indicates that the white-light-emitting phosphor could be pumped by near-UV light.

  13. SU-F-18C-13: Low-Dose X-Ray CT Reconstruction Using a Hybrid First-Order Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, L; Lin, W; Jin, M

    2014-06-15

    Purpose: To develop a novel reconstruction method for X-ray CT that can lead to accurate reconstruction at significantly reduced dose levels combining low X-ray incident intensity and few views of projection data. Methods: The noise nature of the projection data at low X-ray incident intensity was modeled and accounted by the weighted least-squares (WLS) criterion. The total variation (TV) penalty was used to mitigate artifacts caused by few views of data. The first order primal-dual (FOPD) algorithm was used to minimize TV in image domain, which avoided the difficulty of the non-smooth objective function. The TV penalized WLS reconstruction wasmore » achieved by alternated FOPD TV minimization and projection onto convex sets (POCS) for data fidelity constraints. The proposed FOPD-POCS method was evaluated using the FORBILD jaw phantom and the real cadaver head CT data. Results: The quantitative measures, root mean square error (RMSE) and contrast-to-noise ratio (CNR), demonstrate the superior denoising capability of WLS over LS-based TV iterative reconstruction. The improvement of RMSE (WLS vs. LS) is 15%∼21% and that of CNR is 17%∼72% when the incident counts per ray are ranged from 1×10{sup 5} to 1×10{sup 3}. In addition, the TV regularization can accurately reconstruct images from about 50 views of the jaw phantom. The FOPD-POCS reconstruction reveals more structural details and suffers fewer artifacts in both the phantom and real head images. The FOPD-POCS method also shows fast convergence at low X-ray incident intensity. Conclusion: The new hybrid FOPD-POCS method, based on TV penalized WLS, yields excellent image quality when the incident X-ray intensity is low and the projection views are limited. The reconstruction is computationally efficient since the FOPD minimization of TV is applied only in the image domain. The characteristics of FOPD-POCS can be exploited to significantly reduce radiation dose of X-ray CT without compromising accuracy for diagnosis or treatment planning.« less

  14. Quantum-splitting oxide-based phosphors and method of producing the same

    DOEpatents

    Setlur, Anant Achyut; Srivastava, Alok Mani

    2003-09-02

    Strontium, calcium, strontium calcium, strontium calcium magnesium, calcium magnesium aluminates, and strontium borates activated with Pr.sup.3+ exhibit characteristics of quantum-splitting phosphors under VUV excitation. A large emission peak at about 405 nm under VUV excitation is used conveniently to identify quantum-splitting phosphors. Improvements may be achieved with addition of fluorides or boric acid as a flux during the preparation of the phosphors. It is also possible to predict improvement in quantum efficiency by observing the ratio of emission intensities at about 480 nm and about 610 nm.

  15. The effect of physician staffing model on patient outcomes in a medical progressive care unit.

    PubMed

    Yoo, E J; Damaghi, N; Shakespeare, W G; Sherman, M S

    2016-04-01

    Although evidence supports the impact of intensivist physician staffing in improving intensive care unit (ICU) outcomes, the optimal coverage for progressive care units (PCU) is unknown. We sought to determine how physician staffing models influence outcomes for intermediate care patients. We conducted a retrospective observational comparison of patients admitted to the medical PCU of an academic hospital during 12-month periods of high-intensity and low-intensity staffing. A total of 318 PCU patients were eligible for inclusion (143 high-intensity and 175 low-intensity). We found that low-intensity patients were more often stepped up from the emergency department and floor, whereas high-intensity patients were ICU transfers (61% vs 42%, P = .001). However, Mortality Probability Model scoring was similar between the 2 groups. In adjusted analysis, there was no association between intensity of staffing and hospital mortality (odds ratio, 0.84; 95% confidence interval, 0.36-1.99; P = .69) or PCU mortality (odds ratio, 0.96; 95% confidence interval, 0.38-2.45; P = .69). There was also no difference in subsequent ICU admission rates or in PCU length of stay. We found no evidence that high-intensity intensivist physician staffing improves outcomes for intermediate care patients. In a strained critical care system, our study raises questions about the role of the intensivist in the graded care options between intensive and conventional ward care. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Elemental ratio measurements of organic compounds using aerosol mass spectrometry: characterization, improved calibration, and implications

    DOE PAGES

    Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; ...

    2014-07-31

    Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), organic mass-to-organic carbon (OM : OC), and carbon oxidation state (OS C) for a vastly expanded laboratory dataset of multifunctional oxidized OA standards. For the expanded standard dataset, the "Aiken-Explicit" method (Aiken et al., 2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios, reproduces known molecular Omore » : C and H : C ratio values within 20% (average absolute value of relative errors) and 12% respectively. The more commonly used "Aiken-Ambient" method, which uses empirically estimated H 2O + and CO + ion intensities to avoid gas phase air interferences at these ions, reproduces O : C and H : C of multifunctional oxidized species within 28% and 14% of known values. These values are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2O +, CO +, and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and H 2O + produced from many oxidized species. Combined AMS-vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method reduces the systematic biases and reproduces O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C and H : C values is smaller (12% and 4% respectively) for synthetic mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.« less

  17. Clinical Implications of the Tumor Volume Reduction Rate in Head-and-Neck Cancer During Definitive Intensity-Modulated Radiotherapy for Organ Preservation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Shih-Neng; Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan; Liao, Chih-Ying

    2011-03-15

    Purpose: To investigate the prognostic value of the volume reduction rate (VRR) in patients with head-and-neck cancer treated with intensity-modulated radiotherapy (IMRT). Methods and Materials: Seventy-six patients with oropharyngeal cancer (OPC) and another 76 with hypopharyngeal cancer (HPC) were enrolled in volumetric analysis. All patients received allocated radiotherapy courses. Adaptive computed tomography was done 4 to 5 weeks after the start of IMRT. Primary tumor volume measurement was derived using separate images for the pretreatment gross tumor volume (pGTV) and the interval gross tumor volume. Results: In the OPC group, the pGTV ranged from 6.6 to 242.6 mL (mean, 49.9more » mL), whereas the value of the VRR ranged from 0.014 to 0.74 (mean, 0.43). In HPC patients, the pGTV ranged from 4.1 to 152.4 mL (mean, 35.6 mL), whereas the VRR ranged from -1.15 to 0.79 (mean, 0.33). Multivariate analysis of the primary tumor relapse-free survival for OPC revealed three prognostic factors: T4 tumor (p = 0.0001, hazard ratio 7.38), pGTV {>=}20 mL (p = 0.01, hazard ratio 10.61), and VRR <0.5 (p = 0.001, hazard ratio 6.49). Multivariate analysis of the primary tumor relapse-free survival for HPC showed two prognostic factors: pGTV {>=}30 mL (p = 0.001, hazard ratio 2.87) and VRR <0.5 (p = 0.03, hazard ratio 2.25). Conclusion: The VRR is an outcome predictor for local control in OPC and HPC patients treated with IMRT. Those with large tumor volumes or a VRR <0.5 should be considered for a salvage operation or a dose-escalation scheme.« less

  18. Quantitative analysis of the breath-holding half-Fourier acquisition single-shot turbo spin-echo technique in abdominal MRI

    NASA Astrophysics Data System (ADS)

    Dong, Kyung-Rae; Goo, Eun-Hoe; Lee, Jae-Seung; Chung, Woon-Kwan

    2013-01-01

    A consecutive series of 50 patients (28 males and 22 females) who underwent hepatic magnetic resonance imaging (MRI) from August to December 2011 were enrolled in this study. The appropriate parameters for abdominal MRI scans were determined by comparing the images (TE = 90 and 128 msec) produced using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) technique at different signal acquisition times. The patients consisted of 15 normal patients, 25 patients with a hepatoma and 10 patients with a hemangioma. The TE in a single patient was set to either 90 msec or 128 msec. This was followed by measurements using the four normal rendering methods of the biliary tract system and the background signal intensity using the maximal signal intensity techniques in the liver, spleen, pancreas, gallbladder, fat, muscles and hemangioma. The signal-to-noise and the contrast-to-noise ratios were obtained. The image quality was assessed subjectively, and the results were compared. The signal-to-noise and the contrast-to-noise ratios were significantly higher at TE = 128 msec than at TE = 90 when diseases of the liver, spleen, pancreas, gallbladder, and fat and muscles, hepatocellular carcinomas and hemangiomas, and rendering the hepatobiliary tract system based on the maximum signal intensity technique were involved (p < 0.05). In addition, the presence of artifacts, the image clarity and the overall image quality were excellent at TE = 128 msec (p < 0.05). In abdominal MRI, the breath-hold half-Fourier acquisition single-shot turbo spin-echo (HASTE) was found to be effective in illustrating the abdominal organs for TE = 128 msec. Overall, the image quality at TE = 128 msec was better than that at TE = 90 msec due to the improved signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Overall, the HASTE technique for abdominal MRI based on a high-magnetic field (3.0 T) at a TE of 128 msec can provide useful data.

  19. Variation of the H-Beta Emission Lines of Yy-Geminorum - Part Two - Change of Sectorial Structures of Active Regions

    NASA Astrophysics Data System (ADS)

    Kodaira, K.; Ichimura, K.

    Sixty-three image-tube spectrograms of YY Gem (4 Å mm-1, λλ4820-4900 Å) are analyzed to yield the radial-velocity curves and the variations in the intensities and the widths of Hβ emission lines during the quiescent phase at epochs 1980 February 11-16, 1981 January 14-15, and 1981 March 11. The emission-line intensity of component A varied in a single-wave mode over an orbital period, with an apparent phase drift, -0.006019 fraction of the period per day from one epoch to another. The pattern of the intensity variation of component B changed within a few years. The ratio of the amplitudes of radial-velocity curves (KA/KB) of Hβ emission was found to be 0.91 in February 1980 but 1.01 in January 1981. This modulation in the ratio is interpreted as the results of the varying inhomogeneous distributions of emission intensities over the stellar surfaces which are inferred from the observed intensity variations under the assumption of synchronous rotation. A ratio KA/KB = 1.00±001 is proposed as the actual value which would be observed if the effects of inhomogeneities were negligible. The double-wave mode of the line-width variation over a period, which was found by Kodaira and Ichimura (1980), persisted for component A but changed into a single-wave mode for component B. No appreciable changes were detected in the average levels of both the intensity and width of Hβ emission lines within the last few years.

  20. Single image super-resolution via regularized extreme learning regression for imagery from microgrid polarimeters

    NASA Astrophysics Data System (ADS)

    Sargent, Garrett C.; Ratliff, Bradley M.; Asari, Vijayan K.

    2017-08-01

    The advantage of division of focal plane imaging polarimeters is their ability to obtain temporally synchronized intensity measurements across a scene; however, they sacrifice spatial resolution in doing so due to their spatially modulated arrangement of the pixel-to-pixel polarizers and often result in aliased imagery. Here, we propose a super-resolution method based upon two previously trained extreme learning machines (ELM) that attempt to recover missing high frequency and low frequency content beyond the spatial resolution of the sensor. This method yields a computationally fast and simple way of recovering lost high and low frequency content from demosaicing raw microgrid polarimetric imagery. The proposed method outperforms other state-of-the-art single-image super-resolution algorithms in terms of structural similarity and peak signal-to-noise ratio.

Top