Idaho Habitat Evaluation for Off-Site Mitigation Record : Annual Report 1988.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Idaho. Dept. of Fish and Game.
1990-03-01
The Idaho Department of Fish and Game (IDFG) has been monitoring and evaluating existing and proposed habitat improvement projects for steelhead and chinook in the Clearwater and Salmon subbasins since 1984. Projects included in the monitoring are funded by, or proposed for funding by, the Bonneville Power Administration (BPA) under the Northwest Power Planning Act as off-site mitigation for downstream hydropower development on the Snake and Columbia Rivers. This monitoring project is also funded under the same authority. A mitigation record is being developed to use actual and potential increases in smolt production as the best measures of benefit frommore » a habitat improvement project. This project is divided into two subprojects: general and intensive monitoring. Primary objectives of the general monitoring subproject are to determine natural production increases due to habitat improvement projects in terms of parr production and to determine natural production status and trends in Idaho. The second objective is accomplished by combining parr density from monitoring and evaluation of BPA habitat projects and from other IDFG management and research activities. The primary objective of the intensive monitoring subproject is to determine the relationships between spawning escapement, parr production, and smolt production in two Idaho streams; the upper Salmon River and Crooked River. Results of the intensive monitoring will be used to estimate mitigation benefits in terms of smolt production and to interpret natural production monitoring in Idaho. 30 refs., 19 figs., 34 tabs.« less
Salmon River Habitat Enhancement. 1990 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowe, Mike
1991-12-01
The annual report contains three individual subproject sections detailing tribal fisheries work completed during the summer and fall of 1990. Subproject I contains summaries of evaluation/monitoring efforts associated with the Bear Valley Creek, Idaho enhancement project. Subproject II contains an evaluation of the Yankee Fork of the Salmon River habitat enhancement project. Subproject III concerns the East Fork of the Salmon River, Idaho.
4.0 Measuring and monitoring forest carbon stocks and fluxes
Jennifer C. Jenkins; Peter S. Murdoch; Richard A. Birdsey; John L. Hom
2008-01-01
Measuring and monitoring forest productivity and carbon (C) is of growing concern for natural resource managers and policymakers. With the Delaware River Basin (DRB) as a pilot region, this subproject of the CEMRI sought to: improve the ability of the ground-based Forest Inventory and Analysis (FIA) networks to more completely assess forest C stocks and fluxes,...
Air Monitoring Network at Tonopah Test Range: Network Description and Capabilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey Tappen; George Nikolich; Ken Giles
2010-05-18
During the period April to June 2008, at the behest of the U.S. Department of Energy (DOE) National Nuclear Security Administration, Nevada Site Office (NNSA/NSO); the Desert Research Institute (DRI) constructed and deployed two portable environmental monitoring stations at the Tonopah Test Range (TTR) as part of the Environmental Restoration Project Soils Sub-Project. The TTR is located within the boundaries of the Nevada Test and Training Range (NTTR) near the northern edge, and covers an area of approximately 725.20 km2 (179,200 acres). The primary objective of the monitoring stations is to evaluate whether and under what conditions there is windmore » transport of radiological contaminants from one of the three Soil Sub-Project Corrective Action Units (CAUs) associated with Operation Roller Coaster on TTR. Operation Roller Coaster was a series of tests, conducted in 1963, designed to examine the stability and dispersal of plutonium in storage and transportation accidents. These tests did not result in any nuclear explosive yield. However, the tests did result in the dispersal of plutonium and contamination of surface soils in the surrounding area.« less
Idaho Habitat/Natural Production Monitoring Part I, 1995 Annual Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall-Griswold, J.A.; Petrosky, C.E.
The Idaho Department of Fish and Game (IDFG) has been monitoring trends in juvenile spring and summer chinook salmon, Oncorhynchus tshawytscha, and steelhead trout, O. mykiss, populations in the Salmon, Clearwater, and lower Snake River drainages for the past 12 years. This work is the result of a program to protect, mitigate, and enhance fish and wildlife affected by the development and operation of hydroelectric power plants on the Columbia River. Project 91-73, Idaho Natural Production Monitoring, consists of two subprojects: General Monitoring and Intensive Monitoring. This report updates and summarizes data through 1995 for the General Parr Monitoring (GPM)more » database to document status and trends of classes of wild and natural chinook salmon and steelhead trout populations. A total of 281 stream sections were sampled in 1995 to monitor trends in spring and summer chinook salmon Oncorhynchus tshawytscha and steelhead trout O. mykiss parr populations in Idaho. Percent carrying capacity and density estimates were summarized for 1985--1995 by different classes of fish: wild A-run steelhead trout, wild B-run steelhead trout, natural A-run steelhead trout, natural B-run steelhead trout, wild spring and summer chinook salmon, and natural spring and summer chinook salmon. The 1995 data were also summarized by subbasins as defined in Idaho Department of Fish and Game`s 1992--1996 Anadromous Fish Management Plan.« less
Population Activities Fund Agency (PAFA): the journey so far.
1993-01-01
Mechanisms are needed funding Nigerian Federal efforts to implement the National Policy on Population for Development, which was approved by the Armed Forces Ruling Council in February, 1988. Subprojects of the Population Activities Fund Agency (PAFA) which were approves are: the integration of family planning (FP) into maternal and child health (MCH) the promotion of Fp through health education, tertiary centers for reproductive health, public enlightenment on population, population/family life education in primary schools, monitoring of National Population Project impact, and integration of population into planning and budgeting. The last obstacle to implementation of PAFA's activities is the signing into law the decree establishing PAFA as a parastatal. The passage is required for continued operations. The national Population for Development policy is unique in providing for quantitative targets, which has attracted the needed financial support of agencies such as the World Bank. As part of the National Population Policy, the National Population Program (NPP) is developing an effective strategy for securing funding and evaluation of subprojects that are designed and implemented b Collaborating Agencies (CAs), both private and public. NPP aims 1) to provide funds for qualified CAs through the Population Activities Fund (PAF) and Agency (PAFA); 2) to monitor PAFA, which manages PAf with the Department of Population Activities, and 3) to stimulate analysis of sociocultural constraints to fertility reduction and international comparisons, and to design innovative interventions through the Population Research Fund (PRF). PAFA funds implementing agencies at all government and nongovernment levels with approaches to population information and services. The goal of PAFA is to realize NPP objectives. The motto is "Towards an improved quality of life for every Nigerian." The mandate is to provide funding for the PAF and NPP, to monitor CAs, to provide assistance to CAs preparing Phase II subprojects, and to supervise and guide CAs on funding, procurement, and implementation.
Java across Different Curricula, Courses and Countries Using a Common Pool of Teaching Material
ERIC Educational Resources Information Center
Ivanovic, Mirjana; Budimac, Zoran; Mishev, Anastas; Bothe, Klaus; Jurca, Ioan
2013-01-01
Under the auspices of a DAAD funded educational project, a subproject devoted to different aspects of teaching the Java programming language started several years ago. The initial intention of the subproject was to attract members of the subproject to prepare some teaching materials for teaching essentials of the Java programming language. During…
Human/Computer Transaction Tasks: An Annotated Bibliography.
1982-05-01
Operations (Manpower, Personnel, and Training, OP-01). The subproject was directed toward resolving fundamental human engineering design issues in...1978 and results were used at the Navy Personnel Research and Development Center in research to resolve fundamental human engineering design issues for...Dialogue Monitor and analysis of Sthe data obtained are briefly discussed. Alden, D. G., Daniels, P. 3., and Kanarick, A. F. Keyboard design and
Metrology for Fuel Cell Manufacturing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stocker, Michael; Stanfield, Eric
2015-02-04
The project was divided into three subprojects. The first subproject is Fuel Cell Manufacturing Variability and Its Impact on Performance. The objective was to determine if flow field channel dimensional variability has an impact on fuel cell performance. The second subproject is Non-contact Sensor Evaluation for Bipolar Plate Manufacturing Process Control and Smart Assembly of Fuel Cell Stacks. The objective was to enable cost reduction in the manufacture of fuel cell plates by providing a rapid non-contact measurement system for in-line process control. The third subproject is Optical Scatterfield Metrology for Online Catalyst Coating Inspection of PEM Soft Goods. Themore » objective was to evaluate the suitability of Optical Scatterfield Microscopy as a viable measurement tool for in situ process control of catalyst coatings.« less
NASA Technical Reports Server (NTRS)
Johnson, Chuck; Griner, James H.; Hayhurst, Kelly J.; Shively, Robert J.; Consiglio, Maria; Muller, Eric; Murphy, James; Kim, Sam
2012-01-01
UAS Integration in the NAS Project overview with details from each of the subprojects. Subprojects include: Communications, Certification, Integrated Test and Evaluation, Human Systems Integration, and Separation Assurance/Sense and Avoid Interoperability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ide, C.
1996-12-31
Tulane and Xavier Universities have singled out the environment as a major strategic focus for research and training for now and beyond the year 2000. the Tulane/Xavier Center for Bioenvironmental Research (CBR) was established in 1989 as the umbrella organization to coordinate environmental research at both universities. CBR projects funded by the DOE under the Hazardous Materials in Aquatic Environments grant are defining the following: (1) the complex interactions that occur during the transport of contaminants through wetlands environments, (2) the actual and potential impact of contaminants on ecological systems and health, (3) the mechanisms and new technologies through whichmore » these impacts might be remediated, and (4) new programs aimed at educating and training environmental workers of the future. The subproject described in this report, `Biomarkers and Risk Assessment in Bayou Trepagnier, LN`, is particularly relevant to the US Department of Energy`s Environmental Restoration and Waste Management program aimed at solving problems related to hazard monitoring and clean-up prioritization at sites with aquatic pollution problems in the DOE complex.« less
Aircraft Noise Reduction Subproject Overview
NASA Technical Reports Server (NTRS)
Fernandez, Hamilton; Nark, Douglas M.; Van Zante, Dale E.
2016-01-01
The material presents highlights of propulsion and airframe noise research being completed for the Advanced Air Transport Technology Project. The basis of noise reduction plans along with representative work for the airframe, propulsion, and propulsion-airframe integration is discussed for the Aircraft Noise reduction Subproject.
A Comparison of Science and Technology Funding for DoD’s Space and Nonspace Programs
2008-01-15
Artificial intelligence for HAARP Multispectral signature libraries Environmental conditions that Ionospheric prediction HAARP Weather software for...Hardware and software for solar HAARP Electromagnetic interference for Plasma theory in the space Subproject details were not available Subproject
External Peer Review Team Report Underground Testing Area Subproject for Frenchman Flat, Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sam Marutzky
2010-09-01
An external peer review was conducted to review the groundwater models used in the corrective action investigation stage of the Underground Test Area (UGTA) subproject to forecast zones of potential contamination in 1,000 years for the Frenchman Flat area. The goal of the external peer review was to provide technical evaluation of the studies and to assist in assessing the readiness of the UGTA subproject to progress to monitoring activities for further model evaluation. The external peer review team consisted of six independent technical experts with expertise in geology, hydrogeology,'''groundwater modeling, and radiochemistry. The peer review team was tasked withmore » addressing the following questions: 1. Are the modeling approaches, assumptions, and model results for Frenchman Flat consistent with the use of modeling studies as a decision tool for resolution of environmental and regulatory requirements? 2. Do the modeling results adequately account for uncertainty in models of flow and transport in the Frenchman Flat hydrological setting? a. Are the models of sufficient scale/resolution to adequately predict contaminant transport in the Frenchman Flat setting? b. Have all key processes been included in the model? c. Are the methods used to forecast contaminant boundaries from the transport modeling studies reasonable and appropriate? d. Are the assessments of uncertainty technically sound and consistent with state-of-the-art approaches currently used in the hydrological sciences? 3. Are the datasets and modeling results adequate for a transition to Corrective Action Unit monitoring studies—the next stage in the UGTA strategy for Frenchman Flat? The peer review team is of the opinion that, with some limitations, the modeling approaches, assumptions, and model results are consistent with the use of modeling studies for resolution of environmental and regulatory requirements. The peer review team further finds that the modeling studies have accounted for uncertainty in models of flow and transport in the Frenchman Flat except for a few deficiencies described in the report. Finally, the peer review team concludes that the UGTA subproject has explored a wide range of variations in assumptions, methods, and data, and should proceed to the next stage with an emphasis on monitoring studies. The corrective action strategy, as described in the Federal Facility Agreement and Consent Order, states that the groundwater flow and transport models for each corrective action unit will consider, at a minimum, the following: • Alternative hydrostratigraphic framework models of the modeling domain. • Uncertainty in the radiological and hydrological source terms. • Alternative models of recharge. • Alternative boundary conditions and groundwater flows. • Multiple permissive sets of calibrated flow models. • Probabilistic simulations of transport using plausible sets of alternative framework and recharge models, and boundary and groundwater flows from calibrated flow models. • Ensembles of forecasts of contaminant boundaries. • Sensitivity and uncertainty analyses of model outputs. The peer review team finds that these minimum requirements have been met. While the groundwater modeling and uncertainty analyses have been quite detailed, the peer review team has identified several modeling-related issues that should be addressed in the next phase of the corrective action activities: • Evaluating and using water-level gradients from the pilot wells at the Area 5 Radioactive Waste Management Site in model calibration. • Re-evaluating the use of geochemical age-dating data to constrain model calibrations. • Developing water budgets for the alluvial and upper volcanic aquifer systems in Frenchman Flat. • Considering modeling approaches in which calculated groundwater flow directions near the water table are not predetermined by model boundary conditions and areas of recharge, all of which are very uncertain. • Evaluating local-scale variations in hydraulic conductivity on the calculated contaminant boundaries. • Evaluating the effects of non-steady-state flow conditions on calculated contaminant boundaries, including the effects of long-term declines in water levels, climatic change, and disruption of groundwater system by potential earthquake faulting along either of the two major controlling fault zones in the flow system (the Cane Spring and Rock Valley faults). • Considering the use of less-complex modeling approaches. • Evaluating the large change in water levels in the vicinity of the Frenchman Flat playa and developing a conceptual model to explain these water-level changes. • Developing a long-term groundwater level monitoring program for Frenchman Flat with regular monitoring of water levels at key monitoring wells. Despite these reservations, the peer review team strongly believes that the UGTA subproject should proceed to the next stage.« less
Underground Test Area Subproject Project Management Plan, Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-06-03
This Project Management Plan (PMP) describes the manner in which the US Department of Energy Nevada Operations Office (DOE/NV) will manage the Underground Test Area (UGTA) Subproject at the Nevada Test Site (NTS). It provides the basic guidance for implementation and the organizational structure for meeting the UGTA objectives.
NASA Astrophysics Data System (ADS)
Wyrzykowski, L.; Udalski, A.; Schechter, P. L.; Szewczyk, O.; Szymanski, M.; Kubiak, M.; Pietrzynski, G.; Soszynski, I.; Zebrun, K.
2003-09-01
We present results of the long term monitoring of the gravitationally lensed quasar HE1104--1805. The photometric data were collected between August 1997 and January 2002 as a subproject of the OGLE survey. We determine the time delay in the light curves of images A and B of HE1104--1805 to be equal to 157+/-21 days with the variability in the image B light curve leading variability of the image A. The result is in excellent agreement with the earlier determination by Ofek and Maoz. OGLE photometry of HE1104--1805 is available to the astronomical community from the OGLE Internet archive.
Artificial Gravity Research Project
NASA Technical Reports Server (NTRS)
Kamman, Michelle R.; Paloski, William H.
2005-01-01
Protecting the health, safety, and performance of exploration-class mission crews against the physiological deconditioning resulting from long-term weightlessness during transit and long-term hypogravity during surface operations will require effective, multi-system countermeasures. Artificial gravity (AG), which would replace terrestrial gravity with inertial forces generated by rotating the transit vehicle or by a human centrifuge device within the transit vehicle or surface habitat, has long been considered a potential solution. However, despite its attractiveness as an efficient, multi-system countermeasure and its potential for improving the environment and simplifying operational activities (e.g., WCS, galley, etc.), much still needs to be learned regarding the human response to rotating environments before AG can be successfully implemented. This paper will describe our approach for developing and implementing a rigorous AG Research Project to address the key biomedical research questions that must be answered before developing effective AG countermeasure implementation strategies for exploration-class missions. The AG Research Project will be performed at JSC, ARC, extramural academic and government research venues, and international partner facilities maintained by DLR and IMBP. The Project includes three major ground-based human research subprojects that will lead to flight testing of intermittent short-radius AG in ISS crewmembers after 201 0, continuous long-radius AG in CEV crews transiting to and from the Moon, and intermittent short-radius AG plus exercise in lunar habitats. These human ground-based subprojects include: 1) a directed, managed international short-radius project to investigate the multi-system effectiveness of intermittent AG in human subjects deconditioned by bed rest, 2) a directed, managed long-radius project to investigate the capacity of humans to live and work for extended periods in rotating environments, and 3) a focused, investigator-initiated project to investigate system-specific adaptation to and from rotating environments. The AG Research Project also includes two major animal research subprojects: 1) a directed, managed ground-based subproject using rodents and, possibly, sub-human primates, to address mechanistic issues that cannot be studied in humans, to rapidly develop higher sample numbers than can be achieved in the human subprojects, and to establish feasible parameter operating bands to reduce the breadth of the human subprojects, and 2) a flight subproject using rodents to estimate the physiological effects of long term exposure to hypogravity and to investigate the effects of contamination by terrestrial gravity in estimating AG effectiveness. The animal flight subproject would be performed aboard ISS using the CAM module in approximately the 2008-201 1 timeframe. The paper will first present an overview of the key biomedical research questions to be answered. It will then describe the overall approaches to be utilized in developing and implementing the AG Research Project, including definition of the intended scientific research, management and development approaches, identification of roles and responsibilities, risk management, and definition of project deliverables. The primary focus of the paper will be on the first of the three ground-based human research subprojects, since it is the only one currently in development and is scheduled to start active subject investigations in April of 2005.
2013-12-01
First, any subproject that involved an implementation shared some implementation infrastructure with other subprojects. For example, the Plaid backend ...very same language. We followed this advice in Plaid, and we therefore implemented the compiler backend in Plaid (code generation, type checker, Æminim...programming language aimed at enforcing security properties in web and mobile applications [Nistor et al., 2013]. Wyvern therefore provides an excellent
ERIC Educational Resources Information Center
Burke, M.; And Others
The purpose of this subproject is to guide students to meet and interact with individuals from the many subcultures in a community (see ED 055 011). This progress report of the second year's activities includes information on the process of curriculum development, the materials developed, evaluation, roles of supporting agencies, behavioral…
Establishment of the Center for Advanced Separation Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christopher E. Hull
2006-09-30
This Final Technical Report covers the eight sub-projects awarded in the first year and the five projects awarded in the second year of Cooperative Agreement DE-FC26-01NT41091: Establishment of the Center for Advanced Separation Technologies. This work is summarized in the body of the main report: the individual sub-project Technical Progress Reports are attached as Appendices.
Crosscutting Technology Development at the Center for Advanced Separation Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christopher E. Hull
2006-09-30
This Technical Progress Report describes progress made on the twenty nine subprojects awarded in the second year of Cooperative Agreement DE-FC26-02NT41607: Crosscutting Technology Development at the Center for Advanced Separation Technologies. This work is summarized in the body of the main report: the individual sub-project Technical Progress Reports are attached as Appendices.
CROSSCUTTING TECHNOLOGY DEVELOPMENT AT THE CENTER FOR ADVANCED SEPARATION TECHNOLOGIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christopher E. Hull
2006-05-15
This Technical Progress Report describes progress made on the twenty nine subprojects awarded in the second year of Cooperative Agreement DE-FC26-02NT41607: Crosscutting Technology Development at the Center for Advanced Separation Technologies. This work is summarized in the body of the main report: the individual sub-project Technical Progress Reports are attached as Appendices.
Novel Materials Design and Fabrication for Army Needs
2012-11-01
Footwear (Dog Booties ). Each sub-project represented an Army need for improved materials and fabrication design. 1. REPORT DATE (DD-MM-YYYY) 4. TITLE...barrier seams, IOTV, patterns, stitchless seams, dog booties Dr. Christine W. Cole, Dr. Deborah K. Lickfield Clemson University Office of Sponsored...Improved OTV patterns, Textile-based options for Reduced Helmet Weight, and Canine Footwear (Dog Booties ). Each sub-project represented an Army need for
NASA Astrophysics Data System (ADS)
Oyedotun, Temitope D. Timothy
2017-11-01
The need and demand for water in the world are becoming acute with the growing population. This is mostly pressing in developing countries of which Mekelle City in Northern Ethiopia is not an exception. World Bank borehole-support sub-project was aimed at addressing this challenge. The evaluation of the intervention indicates that there is a significant increase in water supply in the city because of the sub-project. However, the increase in water supply has not been able to meet up with the already established and increasing demand. Coupled with this challenge are: the limited capacity of human capital and expertise that will ensure the proper management of borehole interventions; insufficient cost recovery for proper operation and maintenance of the projects; loss of land and farmlands and lack of compensations because of the projects which affect the livelihood.
Airspace Technology Demonstration 2 (ATD-2) Phase 1 Concept of Use (ConUse)
NASA Technical Reports Server (NTRS)
Jung, Yoon; Engelland, Shawn; Capps, Richard; Coppenbarger, Rich; Hooey, Becky; Sharma, Shivanjli; Stevens, Lindsay; Verma, Savita; Lohr, Gary; Chevalley, Eric;
2018-01-01
This document presents an operational Concept of Use (ConUse) for the Phase 1 Baseline Integrated Arrival, Departure, and Surface (IADS) prototype system of NASA's Airspace Technology Demonstration 2 (ATD-2) sub-project, which began demonstration in 2017 at Charlotte Douglas International Airport (CLT). NASA is developing the IADS system under the ATD-2 sub-project in coordination with the Federal Aviation Administration (FAA) and aviation industry partners. The primary goal of ATD-2 sub-project is to improve the predictability and the operational efficiency of the air traffic system in metroplex environments, through the enhancement, development, and integration of the nation's most advanced and sophisticated arrival, departure, and surface prediction, scheduling, and management systems. The ATD-2 effort is a five-year research activity through 2020. The initial phase of the ATD-2 sub-project, which is the focus of this document, will demonstrate the Phase 1 Baseline IADS capability at CLT in 2017. The Phase 1 Baseline IADS capabilities of the ATD-2 sub-project consists of: (a) Strategic and tactical surface scheduling to improve efficiency and predictability of airport surface operations, (b) Tactical departure scheduling to enhance merging of departures into overhead traffic streams via accurate predictions of takeoff times and automated coordination between the Airport Traffic Control Tower (ATCT, or Tower) and the Air Route Traffic Control Center (ARTCC, or Center), (c) Improvements in departure surface demand predictions in Time Based Flow Management (TBFM), (d) A prototype Electronic Flight Data (EFD) system provided by the FAA via the Terminal Flight Data Manager (TFDM) early implementation effort, and (e) Improved situational awareness and demand predictions through integration with the Traffic Flow Management System (TFMS), TBFM, and TFDM (3Ts) for electronic data integration and exchange, and an on-screen dashboard displaying pertinent analytics in real-time. The surface scheduling and metering element of the capability is consistent with the Surface CDM Concept of Operations published in 2014 by the FAA Surface Operations Directorate.1 Upon successful demonstration of the Phase 1 Baseline IADS capability, follow-on demonstrations of the matured IADS traffic management capabilities will be conducted in the 2018-2020 timeframe. At the end of each phase of the demonstrations, NASA will transfer the ATD-2 sub-project technology to the FAA and industry partners.
User Participation in Coproduction of Health Innovation: Proposal for a Synergy Project
Zukauskaite, Elena; Westberg, Niklas
2018-01-01
Background This project concerns advancing knowledge, methods, and logic for user participation in coproduction of health innovations. Such advancement is vital for several reasons. From a user perspective, participation in coproduction provides an opportunity to gain real influence over goal definition, design, and implementation of health innovations, ensuring that the solution developed solves real problems in right ways. From a societal perspective, it’s a mean to improve the efficiency of health care and the implementation of the Patient Act. As for industry, frameworks and knowledge of coproduction offer tools to operate in a complex sector, with great potential for innovation of services and products. Objective The fundamental objective of this project is to advance knowledge and methods of how user participation in the coproduction of health innovations can be applied in order to benefit users, industry, and public sector. Methods This project is a synergy project, which means that the objective will be accomplished through collaboration and meta-analysis between three subprojects that address different user groups, apply different strategies to promote human health, and relate to different parts of the health sector. Furthermore, subprojects focus on distinctive stages in the spectrum of innovation, with the objective to generate knowledge of the innovation process as a whole. The project is organized around three work packages related to three challenges—coproduction, positioning, and realization. Each subproject is designed such that it has its own field of study with clearly identified objectives but also targets work packages to contribute to the project as a whole. The work on the work packages will use case methodology for data collection and analysis based on the subprojects as data sources. More concretely, logic of multiple case studies will be applied with each subproject representing a separate case which is similar to each other in its attention to user participation in coproduction, but different regarding, for example, context and target groups. At the synergy level, the framework methodology will be used to handle and analyze the vast amount of information generated within the subprojects. Results The project period is from July 1, 2018 to June 30, 2022. Conclusions By addressing the objective of this project, we will create new knowledge on how to manage challenges to health innovation associated with the coproduction process, the positioning of solutions, and realization. PMID:29743159
NASA Technical Reports Server (NTRS)
Griner, Jim; Kerczewski, Bob
2017-01-01
In order to provide for the safe integration of unmanned aircraft systems (UAS) into the National Airspace System, the command and control communications link connecting the ground-based pilot with the unmanned aircraft must be highly reliable and robust, with national and international standards to enable interoperability and certification. Both line-of-sight (LOS) links using terrestrial-based communications and beyond-line-of-sight (BLOS) links using satellite communications, supported by national and international standards, are required for integrated UAS operations. The National Aeronautics and Space Administration (NASA) has undertaken an extensive technology development and test program in order to provide the required technical data needed to enable C2 standards development. NASAs UAS Integration in the National Airspace System (NAS), or UAS in the NAS Project, included as a major element the Command and Control Communications (C2) Subproject, based at NASAs Glenn Research Center. The successful first phase of the C2 Subproject, completed during 2012-2016, focused primarily on line-of-sight communications. Accomplishments included air-ground channel propagation characterization and modeling; CNPC prototype radio development; CNPC radio flight testing; satellite communications spectrum study and interference analysis; and development of C2 LOS communications standards development. The second phase of the C2 Subproject will focus primarily on beyond-line-of-sight communications, although a follow-on activity for terrestrial LOS communications, known as Terrestrial Extension, is also included. In addition to the terrestrial element, Phase 2 also includes technology development and testing activities for Ka-Band BLOS C2 Satellite Communications; Ku-Band BLOS C2 Satellite Communications; Ku-Band Interference and Propagation; and C-Band Satellite Communications. This paper will provide brief overviews of the C2 Subproject and its Phase I accomplishments, followed by a description of the plans for the C2 Subproject Phase 2.
NASA Technical Reports Server (NTRS)
Griner, James H.; Kerczewski, Robert J.
2017-01-01
In order to provide for the safe integration of unmanned aircraft systems (UAS) into the National Airspace System, the command and control communications link connecting the ground-based pilot with the unmanned aircraft must be highly reliable and robust, with national and international standards to enable interoperability and certification. Both line-of-sight (LOS) links using terrestrial-based communications and beyond-line-of-sight (BLOS) links using satellite communications, supported by national and international standards, are required for integrated UAS operations. The National Aeronautics and Space Administration (NASA) has undertaken an extensive technology development and test program in order to provide the required technical data needed to enable C2 standards development. NASAs UAS Integration in the National Airspace System (NAS), or UAS in the NAS Project, included as a major element the Command and Control Communications (C2) Subproject, based at NASAs Glenn Research Center. The successful first phase of the C2 Subproject, completed during 2012-2016, focused primarily on line-of-sight communications. Accomplishments included air-ground channel propagation characterization and modeling; CNPC prototype radio development; CNPC radio flight testing; satellite communications spectrum study and interference analysis; and development of C2 LOS communications standards development. The second phase of the C2 Subproject will focus primarily on beyond-line-of-sight communications, although a follow-on activity for terrestrial LOS communications, known as Terrestrial Extension, is also included. In addition to the terrestrial element, Phase 2 also includes technology development and testing activities for Ka-Band BLOS C2 Satellite Communications; Ku-Band BLOS C2 Satellite Communications; Ku-Band Interference and Propagation; and C-Band Satellite Communications. This paper will provide brief overviews of the C2 Subproject and its Phase I accomplishments, followed by a description of the plans for the C2 Subproject Phase 2.
Tunisia Renewable Energy Project systems description report
NASA Technical Reports Server (NTRS)
Scudder, L. R.; Martz, J. E.; Ratajczak, A. F.
1986-01-01
In 1979, the Agency for International Development (AID) initiated a renewable energy project with the Government of Tunisia to develop an institutional capability to plan and institute renewable energy technologies in a rural area. The specific objective of the district energy applications subproject was to demonstrate solar and wind energy systems in a rural village setting. The NASA Lewis Research Center was asked by the AID Near East Bureau to manage and implement this subproject. This report describes the project and gives detailed desciptions of the various systems.
NASA Astrophysics Data System (ADS)
Wahl, Thomas; Jensen, Jürgen; Mudersbach, Christoph
2010-05-01
Storm surges along the German North Sea coastline led to major damages in the past and the risk of inundation is expected to increase in the course of an ongoing climate change. The knowledge of the characteristics of possible storm surges is essential for the performance of integrated risk analyses, e.g. based on the source-pathway-receptor concept. The latter includes the storm surge simulation/analyses (source), modelling of dike/dune breach scenarios (pathway) and the quantification of potential losses (receptor). In subproject 1b of the German joint research project XtremRisK (www.xtremrisk.de), a stochastic storm surge generator for the south-eastern North Sea area is developed. The input data for the multivariate model are high resolution sea level observations from tide gauges during extreme events. Based on 25 parameters (19 sea level parameters and 6 time parameters) observed storm surge hydrographs consisting of three tides are parameterised. Followed by the adaption of common parametric probability distributions and a large number of Monte-Carlo-Simulations, the final reconstruction leads to a set of 100.000 (default) synthetic storm surge events with a one-minute resolution. Such a data set can potentially serve as the basis for a large number of applications. For risk analyses, storm surges with peak water levels exceeding the design water levels are of special interest. The occurrence probabilities of the simulated extreme events are estimated based on multivariate statistics, considering the parameters "peak water level" and "fullness/intensity". In the past, most studies considered only the peak water levels during extreme events, which might not be the most important parameter in any cases. Here, a 2D-Archimedian copula model is used for the estimation of the joint probabilities of the selected parameters, accounting for the structures of dependence overlooking the margins. In coordination with subproject 1a, the results will be used as the input for the XtremRisK subprojects 2 to 4. The project is funded by the German Federal Ministry of Education and Research (BMBF) (Project No. 03 F 0483 B).
User Participation in Coproduction of Health Innovation: Proposal for a Synergy Project.
Nygren, Jens; Zukauskaite, Elena; Westberg, Niklas
2018-05-09
This project concerns advancing knowledge, methods, and logic for user participation in coproduction of health innovations. Such advancement is vital for several reasons. From a user perspective, participation in coproduction provides an opportunity to gain real influence over goal definition, design, and implementation of health innovations, ensuring that the solution developed solves real problems in right ways. From a societal perspective, it's a mean to improve the efficiency of health care and the implementation of the Patient Act. As for industry, frameworks and knowledge of coproduction offer tools to operate in a complex sector, with great potential for innovation of services and products. The fundamental objective of this project is to advance knowledge and methods of how user participation in the coproduction of health innovations can be applied in order to benefit users, industry, and public sector. This project is a synergy project, which means that the objective will be accomplished through collaboration and meta-analysis between three subprojects that address different user groups, apply different strategies to promote human health, and relate to different parts of the health sector. Furthermore, subprojects focus on distinctive stages in the spectrum of innovation, with the objective to generate knowledge of the innovation process as a whole. The project is organized around three work packages related to three challenges-coproduction, positioning, and realization. Each subproject is designed such that it has its own field of study with clearly identified objectives but also targets work packages to contribute to the project as a whole. The work on the work packages will use case methodology for data collection and analysis based on the subprojects as data sources. More concretely, logic of multiple case studies will be applied with each subproject representing a separate case which is similar to each other in its attention to user participation in coproduction, but different regarding, for example, context and target groups. At the synergy level, the framework methodology will be used to handle and analyze the vast amount of information generated within the subprojects. The project period is from July 1, 2018 to June 30, 2022. By addressing the objective of this project, we will create new knowledge on how to manage challenges to health innovation associated with the coproduction process, the positioning of solutions, and realization. ©Jens Nygren, Elena Zukauskaite, Niklas Westberg. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 09.05.2018.
Airframe Technology Development for Next Generation Launch Vehicles
NASA Technical Reports Server (NTRS)
Glass, David E.
2004-01-01
The Airframe subproject within NASA's Next Generation Launch Technology (NGLT) program has the responsibility to develop airframe technology for both rocket and airbreathing vehicles for access to space. The Airframe sub-project pushes the state-of-the-art in airframe technology for low-cost, reliable, and safe space transportation. Both low and medium technology readiness level (TRL) activities are being pursued. The key technical areas being addressed include design and integration, hot and integrated structures, cryogenic tanks, and thermal protection systems. Each of the technologies in these areas are discussed in this paper.
Continuation of Crosscutting Technology Development at Cast
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Roe-Hoan
2012-03-31
This Final Technical Report describes progress made on the sub-projects awarded in the Cooperative Agreement DE-FC26-05NT42457: Continuation of Crosscutting Technology Development at Center for Advanced Separation Technologies (CAST). The final reports for each sub-project are attached in the appendix. Much of the research to be conducted with Cooperative Agreement funds will be longer-term, high-risk, basic research and will be carried out in five broad areas: a) Solid-solid separation b) Solid-liquid separation c) Chemical/Biological Extraction d) Modeling and Control, and e) Environmental Control.
dos, Santos Luís Augusto; Marin, Heimar de Fátima; Marques, Isaac Rosa; Cunha, Isabel Cristina Kowal Olm
2007-01-01
This work intents, in a didactic form, to explain the benefits of use of a technique of project management, named Work Breakdown Structure: a graphical tool to identify the main results to be developed in a project. The real examples are applied to a sub-project of the Virtual Library in Health in Nursing (BVS-Enfermagem) to development of the Sites Catalogs. The benefits of graphical visualization for a major agreement between professionals of different expertise are presented.
Photovoltaic test and demonstration project. [residential energy program
NASA Technical Reports Server (NTRS)
Forestieri, A. F.; Brandhorst, H. W., Jr.; Deyo, J. N.
1976-01-01
The considered project consists of three subprojects related to applications, device performance and diagnostics, and endurance testing. The objectives of the applications subproject include the determination of the operating characteristics for a variety of photovoltaic conversion systems. A system test facility is being constructed in this connection and a prototype residence experiment is to be conducted. Market demand for solar cells is to be stimulated by demonstrating suitability of solar cells for specific near-term applications. Activities conducted in connection with device performance studies and diagnostics are also discussed along with developments in the area of endurance testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eric E. Roden
2009-07-08
This report summarizes research conducted in conjunction with a project entitled “Integrated Nucleic Acid System for In-Field Monitoring of Microbial Community Dynamics and Metabolic Activity”, which was funded through the Integrative Studies Element of the former NABIR Program (now the Environmental Remediation Sciences Program) within the Office of Biological and Environmental Research. Dr. Darrell Chandler (originally at Argonne National Laboratory, now with Akonni Biosystems) was the overall PI/PD for the project. The overall project goals were to (1) apply a model iron-reducer and sulfate-reducer microarray and instrumentation systems to sediment and groundwater samples from the Scheibe et al. FRC Areamore » 2 field site, UMTRA sediments, and other DOE contaminated sites; (2) continue development and expansion of a 16S rRNA/rDNA¬-targeted probe suite for microbial community dynamics as new sequences are obtained from DOE-relevant sites; and (3) address the fundamental molecular biology and analytical chemistry associated with the extraction, purification and analysis of functional genes and mRNA in environmental samples. Work on the UW subproject focused on conducting detailed batch and semicontinuous culture reactor experiments with uranium-contaminated FRC Area 2 sediment. The reactor experiments were designed to provide coherent geochemical and microbiological data in support of microarray analyses of microbial communities in Area 2 sediments undergoing biostimulation with ethanol. A total of four major experiments were conducted (one batch and three semicontinuous culture), three of which (the batch and two semicontinuous culture) provided samples for DNA microarray analysis. A variety of other molecular analyses (clone libraries, 16S PhyloChip, RT-PCR, and T-RFLP) were conducted on parallel samples from the various experiments in order to provide independent information on microbial community response to biostimulation.« less
NASA Astrophysics Data System (ADS)
Xue, Changsheng; Li, Qingquan; Li, Deren
2004-02-01
In 1988, the detail information on land resource was investigated in China. Fourteen years later, it has changed a lot. It is necessary that the second land resource detailed investigation should be implemented. On this condition, the New National Land and Resources Investigation Project in China, which will last 12 years, has been started since 1999. The project is directly under the administration of the Ministry of Land and Resource (MLR). It was organized and implemented By China Geological, China Land Surveying and Planning Institute (CLSPI) and Information Center of MLR. It is a grand and cross century project supported by the Central Finance, based on State and public interests and strategic characteristics. Up to now, "Land Use Dynamic Monitoring By Remote Sensing," "Arable Land Resource Investigation," "Rural Collective Land Property Right Investgiation," "Establishment of Public Consulting Standardization of Cadastral Information," "Land Resource Fundamental Maps and Data Updating," "Urban Land Price Investigation and Intensive Utilization Potential Capacity Evaluation," "Farmland Classification, Gradation, and Evaluation," "Land Use Database Construction at City or County Level" 8 subprojects have had the preliminary achievements. In this project, SPOT-1/2/4 and Landsat-7 TM data were always applied to monitor land use dynamic change as the main data resource. Certainly, IRS, CBERS-2, and IKONOS data also were tested in small areas. In 2002, the SPOT-5 data, whose spatial resolution of the panchromatic image is 2.5 meters and the spectral one is 10 meters, were applied into update the land use base map at the 1:10000 scale in 26 Chinese cities. The purpose in this paper is to communicate the experience of SPOT-5 image processing with the colleagues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Volume VIII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the risk assessment documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Volume VII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the tritium transport model documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Quality assurance aspects of GSR analysis by SEM/EDX: a report of first-hand experiences
NASA Astrophysics Data System (ADS)
Charles, Sebastien; Dehan, Didier; Geusens, Nadia; Nys, Bart
2009-05-01
Like many forensic science labs, the Belgian National Institute of Forensic Science (NICC) is involved in a Quality Assurance program aiming towards an ISO17025 Accreditation. Since last year, a project is underway in the GSR lab to validate the method used in the analysis of GSR samples acquired from the hands of suspects by SEM/EDX. The project is well underway, and is planned to lead to accreditation for this technique by the start of 2010. The presentation will discuss several aspects of the functioning of the lab that have to be addressed when preparing for this accreditation. Some of these issues and problems are so involved that separate sub-projects were defined in order to provide a manageable solution. The following topics will be treated in detail: definition of the scope of the accreditation, the validation of the SEM/EDX method with respect to : accuracy, precision, reproducibility and robustness, and the documentation of the Chain of Custody (CoC) of the samples and their storage. One specific sub-project that will be discussed is the study of contamination monitoring in different relevant locations of the lab. Finally, as we have recently acquired a new microscope, the technical criteria we used in the acquisition study will be presented with a focus on their relevance in a QA context. We feel this discussion is informative, both for labs that are pursuing a formal accreditation in the future, and those that work already in such a context and are in the process of acquiring new equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Labutti, Kurt; Foster, Brian; Lapidus, Alla
Gap Resolution is a software package that was developed to improve Newbler genome assemblies by automating the closure of sequence gaps caused by repetitive regions in the DNA. This is done by performing the follow steps:1) Identify and distribute the data for each gap in sub-projects. 2) Assemble the data associated with each sub-project using a secondary assembler, such as Newbler or PGA. 3) Determine if any gaps are closed after reassembly, and either design fakes (consensus of closed gap) for those that closed or lab experiments for those that require additional data. The software requires as input a genomemore » assembly produce by the Newbler assembler provided by Roche and 454 data containing paired-end reads.« less
Propulsion Noise Reduction Research in the NASA Advanced Air Transport Technology Project
NASA Technical Reports Server (NTRS)
Van Zante, Dale; Nark, Douglas; Fernandez, Hamilton
2017-01-01
The Aircraft Noise Reduction (ANR) sub-project is focused on the generation, development, and testing of component noise reduction technologies progressing toward the NASA far term noise goals while providing associated near and mid-term benefits. The ANR sub-project has efforts in airframe noise reduction, propulsion (including fan and core) noise reduction, acoustic liner technology, and propulsion airframe aeroacoustics for candidate conventional and unconventional aircraft configurations. The current suite of propulsion specific noise research areas is reviewed along with emerging facility and measurement capabilities. In the longer term, the changes in engine and aircraft configuration will influence the suite of technologies necessary to reduce noise in next generation systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irene Farnham
This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurancemore » Project Plan, Nevada Test Site, Nevada, Revision 4.« less
DOE Chair of Excellence in Environmental Disciplines-Final Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurunganty, Sastry; Loran, Roberto; Roque-Malherbe, Rolando
The report Massie Chair of Excellence Program at Universidad del Turabo, contract DE-FG02-95EW12610, during the period of 9/29/1995 to 9/29/2011. The initial program aims included development of academic programs in the Environmental Sciences and Engineering, and Research and Development focused initially on environmentally friendly processes and later revised also include: renewable energy and international cooperation. From 1995 -2005, the Program at UT lead the establishment of the new undergraduate program in electrical engineering at the School of Engineering (SoE), worked on requirements to achieve ABET accreditation of the SoE B.S. Mechanical Engineering and B.S. Electrical Engineering programs, mentored junior faculty,more » taught undergraduate courses in electrical engineering, and revised the electrical engineering curriculum. Engineering undergraduate laboratories were designed and developed. The following research sub-project was developed: Research and development of new perovskite-alumina hydrogen permeable asymmetrical nanostructured membranes for hydrogen purification, and extremely high specific surface area silica materials for hydrogen storage in the form of ammonia, Dr. Rolando Roque-Malherbe Subproject PI, Dr. Santander Nieto and Mr. Will Gómez Research Assistants. In 2006, the Massie Chair of Excellence Program was transferred to the National Nuclear Security Agency, NNSA and DNN. DoE required a revised proposal aligned with the priorities of the Administration. The revised approved program aims included: (1) Research (2) Student Development: promote the development of minority undergraduate and graduate students through research teams, internships, conferences, new courses; and, (3) Support: (a) Research administration and (b) Dissemination through international conferences, the UT Distinguished Lecturer Series in STEM fields and at the annual Universidad del Turabo (UT) Researchers Conference. Research included: Sub-Project 1: Synthesis and Characterization of low Refractive Index Aerogel Silica for Cherenkov Counters- Dr. Rolando Roque-Malherbe Sub-project PI, Dr. Jose Duconge Sub-project Co-PI, Dr. Santander Nieto Assistant Researcher, Francisco Diaz and Carlos Neira Associate Researchers. The initial aim of this sub-project was changed to the synthesis and characterization of extremely high specific surface area aerogel silica for gas storage. A high specific surface area silica gel that has applications in gas drying, cleaning operation useful in nuclear industry in process was developed. Sub-Project 2: Investigation Study of Magnetic and Electronic Transport Properties at Material Interfaces in Magnetic Multilayer Heterostructure using Gd. – Dr. Yazan Hijazi, Sub-project Co-PI. UT developed the capability and infrastructure to produce high quality thin-film magnetic films and magnetic multilayer structures with fine control over film quality and thickness using sputter deposition capability to perform in-house electric and magnetic characterization of these films. The research experimentally quantified the effect of Gd incorporation within the magnetic multilayer structure and produce magnetic media with exchanged decoupled multilevel magnetic anisotropy. From September 2006 to September 2011 the Massie Chair produced nineteen (19) publications, (including 3 books), five (5) presentations and three (3) international conferences abstracts. A total of fourteen (14) undergraduates and (6) graduate students acquired research experience. Two Ph.D. students presented their dissertations on topics related to nuclear energy and graduated as follows: María Cotto (May 2009) and Eric Calderón (May 2011). Five of the participating undergraduate students graduated: Ramon Polanco (BSME, May 2009), Jason Pérez (BSEE, May 2008), Rafael Colón (BSME, May 2008), Jessenia Marfisi (BS Chemistry, May 2008). Eleven (11) students were sent to National Laboratories (LANL, SNL and LLNL), NNSA and DoE facilities for summer internships. Twenty eight (28) undergraduate students participated in Summer Internships (2010, 2011) at the Puerto Rico Energy Center (PREC). Four international energy symposiums were held aligned with the DoE and the NNSA missions and dissemination of Massie Chair research activities (660 attendees). Academic programs developed or revised under advice of the Massie Chair: Ph.D. in Environmental Sciences (revised); MSc in Environmental Sciences (revised); MSc in Mechanical Engineering with concentration in Alternative Energy (new); BS in Industrial Management & Engineering (revised to fulfill the ABET requirements); BS in Civil Engineering including an environmental option (new); BS in Electrical Engineering (revised); and, Associate in Renewable Energy (new). The Puerto Rico Energy Center (PREC) was designed and developed under the Massie Chair initiative. Thirty-three (33) proposals were developed and submitted during the period of which 12 were approved in the amount of $ $1,931,306.« less
NASA Technical Reports Server (NTRS)
Aquilina, Rudolph A.
2015-01-01
The SMART-NAS Testbed for Safe Trajectory Based Operations Project will deliver an evaluation capability, critical to the ATM community, allowing full NextGen and beyond-NextGen concepts to be assessed and developed. To meet this objective a strong focus will be placed on concept integration and validation to enable a gate-to-gate trajectory-based system capability that satisfies a full vision for NextGen. The SMART-NAS for Safe TBO Project consists of six sub-projects. Three of the sub-projects are focused on exploring and developing technologies, concepts and models for evolving and transforming air traffic management operations in the ATM+2 time horizon, while the remaining three sub-projects are focused on developing the tools and capabilities needed for testing these advanced concepts. Function Allocation, Networked Air Traffic Management and Trajectory Based Operations are developing concepts and models. SMART-NAS Test-bed, System Assurance Technologies and Real-time Safety Modeling are developing the tools and capabilities to test these concepts. Simulation and modeling capabilities will include the ability to assess multiple operational scenarios of the national airspace system, accept data feeds, allowing shadowing of actual operations in either real-time, fast-time and/or hybrid modes of operations in distributed environments, and enable integrated examinations of concepts, algorithms, technologies, and NAS architectures. An important focus within this project is to enable the development of a real-time, system-wide safety assurance system. The basis of such a system is a continuum of information acquisition, analysis, and assessment that enables awareness and corrective action to detect and mitigate potential threats to continuous system-wide safety at all levels. This process, which currently can only be done post operations, will be driven towards "real-time" assessments in the 2035 time frame.
BUILDING MATERIALS RECLAMATION PROGRAM
DOE Office of Scientific and Technical Information (OSTI.GOV)
David C. Weggel; Shen-En Chen; Helene Hilger
2010-08-31
This report describes work conducted on the Building Materials Reclamation Program for the period of September 2008 to August 2010. The goals of the project included selecting materials from the local construction and demolition (C&D) waste stream and developing economically viable reprocessing, reuse or recycling schemes to divert them from landfill storage. Educational resources as well as conceptual designs and engineering feasibility demonstrations were provided for various aspects of the work. The project was divided into two distinct phases: Research and Engineering Feasibility and Dissemination. In the Research Phase, a literature review was initiated and data collection commenced, an advisorymore » panel was organized, and research was conducted to evaluate high volume C&D materials for nontraditional use; five materials were selected for more detailed investigations. In the Engineering Feasibility and Dissemination Phase, a conceptual study for a regional (Mecklenburg and surrounding counties) collection and sorting facility was performed, an engineering feasibility project to demonstrate the viability of recycling or reuse schemes was created, the literature review was extended and completed, and pedagogical materials were developed. Over the two-year duration of the project, all of the tasks and subtasks outlined in the original project proposal have been completed. The Final Progress Report, which briefly describes actual project accomplishments versus the tasks/subtasks of the original project proposal, is included in Appendix A of this report. This report describes the scientific/technical aspects (hypotheses, research/testing, and findings) of six subprojects that investigated five common C&D materials. Table 1 summarizes the six subprojects, including the C&D material studied and the graduate student and the faculty advisor on each subproject.« less
Charcoal as an alternative energy source. sub-project: briquetting of charcoal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enstad, G.G.
1982-02-02
Charcoal briquettes have been studied both theoretically and experimentally. It appears most realistic to use binders in solution. Binders of this kind have been examined and the briquettes' mechanical properties measured. Most promising are borresperse, gum arabic, dynolex, and wood tar.
Integrated resource inventory for southcentral Alaska (INTRISCA)
NASA Technical Reports Server (NTRS)
Burns, T.; Carson-Henry, C.; Morrissey, L. A.
1981-01-01
The Integrated Resource Inventory for Southcentral Alaska (INTRISCA) Project comprised an integrated set of activities related to the land use planning and resource management requirements of the participating agencies within the southcentral region of Alaska. One subproject involved generating a region-wide land cover inventory of use to all participating agencies. Toward this end, participants first obtained a broad overview of the entire region and identified reasonable expectations of a LANDSAT-based land cover inventory through evaluation of an earlier classification generated during the Alaska Water Level B Study. Classification of more recent LANDSAT data was then undertaken by INTRISCA participants. The latter classification produced a land cover data set that was more specifically related to individual agency needs, concurrently providing a comprehensive training experience for Alaska agency personnel. Other subprojects employed multi-level analysis techniques ranging from refinement of the region-wide classification and photointerpretation, to digital edge enhancement and integration of land cover data into a geographic information system (GIS).
NASA Astrophysics Data System (ADS)
Gouwens, C.; Dragosavic, M.
The large reserves and increasing use of natural gas as a source of energy have resulted in its storage and transport becoming an urgent problem. Since a liquid of the same mass occupies only a fraction of the volume of a gas, it is economical to store natural gas as a liquid. Liquefied natural gas is stored in insulated tanks and also carried by ship at a temperature of -160 C to 170 C. If a serious accident allows the LNG to escape, a gas cloud forms. The results of a possible explosion from such a gas cloud are studied. The development of a leak, escape and evaporation, size and propagation of the gas cloud, the explosive pressures to be expected and the results on the environment are investigated. Damage to buildings is examined making use of the preliminary conclusions of the other sub-projects and especially the explosive pressures.
NASA Technical Reports Server (NTRS)
Sakahara, Robert; Hackenberg, Davis; Johnson, William
2017-01-01
This presentation was presented to the Integrated Aviation Systems Program at the FY17 Annual Review of the UAS-NAS project. The presentation captures the overview of the work completed by the UAS-NAS project and its subprojects.
Communication, Cooperation, and Negotiation in Culturally Heterogeneous Groups.
ERIC Educational Resources Information Center
Fiedler, Fred E.; Triandis, Harry C.
This research program has been concerned with three major subprojects: identifying concepts and behaviors which critically affect intercultural relations; developing principles and methods for programed self-instructional cultural training to help Americans adjust to, and work more effectively in, foreign cultures, or with persons from different…
Better than a Professional? Students as Co-Contributors to Educational Design
ERIC Educational Resources Information Center
Roberts, Josie; Bolstad, Rachel
2010-01-01
The New Zealand Council for Educational Research's (NZCER's) Families and Communities Engagement (FACE) project is investigating ideas and practices involved in bringing together teachers, families, local communities and students to contribute to collective conversations and decisions about education. This report concerns a sub-project of FACE…
75 FR 61197 - Notice of Entering Into a Compact With the Republic of the Philippines
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-04
... Project ($214.4 million) The Secondary National Roads Development Project is designed to reduce.... This project will incorporate enhanced safety measures in the final road designs, including: (i) Paved... assess and classify every proposed sub-project, and provide the engineering design and oversight support...
Redis database administration tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, J. J.
2013-02-13
MyRedis is a product of the Lorenz subproject under the ASC Scirntific Data Management effort. MyRedis is a web based utility designed to allow easy administration of instances of Redis databases. It can be usedd to view and manipulate data as well as run commands directly against a variety of different Redis hosts.
Sub-Project 7 of Wisconsin 553, Part F, EPDA--Industry/Exchange Program: Final Report.
ERIC Educational Resources Information Center
Wisconsin Univ. - Stout, Menomonie. Center for Vocational, Technical and Adult Education.
The final report describes a study to develop a statewide teacher/industry exchange program in Wisconsin that would provide vocational-technical instructors with occupational experience opportunities. Three plans for implementing the program were developed: (A) swapping the positions of a business or industrial person with that of a vocational…
Capturing business requirements for the Swedish national information structure.
Kajbjer, Karin; Johansson, Catharina
2009-01-01
As a subproject for the National Information Structure project of the National Board of Health and Welfare, four different stakeholder groups were used to capture business requirements. These were: Subjects of care, Health professionals, Managers/Research and Industry. The process is described with formulating goal models, concept, process and information models.
UAS Integration in the NAS Project: Integrated Test and LVC Infrastructure
NASA Technical Reports Server (NTRS)
Murphy, Jim; Hoang, Ty
2015-01-01
Overview presentation of the Integrated Test and Evaluation sub-project of the Unmanned Aircraft System (UAS) in the National Airspace System (NAS). The emphasis of the presentation is the Live, Virtual, and Constructive (LVC) system (a broadly used name for classifying modeling and simulation) infrastructure and use of external assets and connection.
Critical Low-Noise Technologies Being Developed for Engine Noise Reduction Systems Subproject
NASA Technical Reports Server (NTRS)
Grady, Joseph E.; Civinskas, Kestutis C.
2004-01-01
NASA's previous Advanced Subsonic Technology (AST) Noise Reduction Program delivered the initial technologies for meeting a 10-year goal of a 10-dB reduction in total aircraft system noise. Technology Readiness Levels achieved for the engine-noise-reduction technologies ranged from 4 (rig scale) to 6 (engine demonstration). The current Quiet Aircraft Technology (QAT) project is building on those AST accomplishments to achieve the additional noise reduction needed to meet the Aerospace Technology Enterprise's 10-year goal, again validated through a combination of laboratory rig and engine demonstration tests. In order to meet the Aerospace Technology Enterprise goal for future aircraft of a 50- reduction in the perceived noise level, reductions of 4 dB are needed in both fan and jet noise. The primary objectives of the Engine Noise Reduction Systems (ENRS) subproject are, therefore, to develop technologies to reduce both fan and jet noise by 4 dB, to demonstrate these technologies in engine tests, and to develop and experimentally validate Computational Aero Acoustics (CAA) computer codes that will improve our ability to predict engine noise.
NASA Technical Reports Server (NTRS)
Aponso, Bimal; Coppenbarger, Richard A.; Jung, Yoon; Quon, Leighton; Lohr, Gary; O’Connor, Neil; Engelland, Shawn
2015-01-01
NASA's Aeronautics Research Mission Directorate (ARMD) collaborates with the FAA and industry to provide concepts and technologies that enhance the transition to the next-generation air-traffic management system (NextGen). To facilitate this collaboration, ARMD has a series of Airspace Technology Demonstration (ATD) sub-projects that develop, demonstrate, and transitions NASA technologies and concepts for implementation in the National Airspace System (NAS). The second of these sub-projects, ATD-2, is focused on the potential benefits to NAS stakeholders of integrated arrival, departure, surface (IADS) operations. To determine the project objectives and assess the benefits of a potential solution, NASA surveyed NAS stakeholders to understand the existing issues in arrival, departure, and surface operations, and the perceived benefits of better integrating these operations. NASA surveyed a broad cross-section of stakeholders representing the airlines, airports, air-navigation service providers, and industry providers of NAS tools. The survey indicated that improving the predictability of flight times (schedules) could improve efficiency in arrival, departure, and surface operations. Stakeholders also mentioned the need for better strategic and tactical information on traffic constraints as well as better information sharing and a coupled collaborative planning process that allows stakeholders to coordinate IADS operations. To assess the impact of a potential solution, NASA sketched an initial departure scheduling concept and assessed its viability by surveying a select group of stakeholders for a second time. The objective of the departure scheduler was to enable flights to move continuously from gate to cruise with minimal interruption in a busy metroplex airspace environment using strategic and tactical scheduling enhanced by collaborative planning between airlines and service providers. The stakeholders agreed that this departure concept could improve schedule predictability and suggested several key attributes that were necessary to make the concept successful. The goals and objectives of the planned ATD-2 sub-project will incorporate the results of this stakeholder feedback.
ERIC Educational Resources Information Center
PLUMPTON, RUSSEL A.
THE METHODS FOR DETERMINING PUPIL READINESS WERE STUDIED TO DEVELOP CRITERIA FOR PUPIL PARTICIPATION IN SIMULATED ENVIRONMENT LEARNING UNITS. THE LEARNING UNITS WERE SUBPROJECTS OF COOPERATIVE RESEARCH PROJECT NUMBER 1948 (ED 003 024). EACH OF THREE UNITS IN THE PROJECT WAS EXAMINED FOR PUPIL READINESS. TEST BATTERIES WERE ASSEMBLED AND…
Finance and supply management project execution plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
BENNION, S.I.
As a subproject of the HANDI 2000 project, the Finance and Supply Management system is intended to serve FDH and Project Hanford major subcontractor with financial processes including general ledger, project costing, budgeting, and accounts payable, and supply management process including purchasing, inventory and contracts management. Currently these functions are performed with numerous legacy information systems and suboptimized processes.
UAS C2 Radio System - Final Phase 1 Development and Testing
NASA Technical Reports Server (NTRS)
Kerczewski, Robert; Shalkhauser, Kurt
2017-01-01
Phase 1 of the Command and Control Communications (C2) Subproject of NASA's UAS Integration in the National Airspace System Project included the development and testing of prototype C2 radio systems. This information paper provides an overview of the functionality and testing of the fifth and final Phase 1 generation of the prototype radio system.
NASA Astrophysics Data System (ADS)
Batzias, F. A.; Sidiras, D. K.; Giannopoulos, Ch.; Spetsidis, I.
2009-08-01
This work deals with a methodological framework designed/developed under the form of a spatio-temporal algorithmic procedure for environmental policymaking at local level. The procedure includes 25 activity stages and 9 decision nodes, putting emphasis on (i) mapping on GIS layers water supply/demand and modeling of aquatic pollution coming from point and non-point sources, (ii) environmental monitoring by periodically measuring the main pollutants in situ and in the laboratory, (iii) design of environmental projects, decomposition of them into sub-projects and combination of the latter to form attainable alternatives, (iv) multicriteria ranking of alternatives, according to a modified Delphi method, by using as criteria the expected environmental benefit, the attitude of inhabitants, the priority within the programme of regional development, the capital required for the investment and the operating cost, and (v) knowledge Base (KB) operation/enrichment, functioning in combination with a data mining mechanism to extract knowledge/information/data from external Bases. An implementation is presented referring to the Municipality of Arkalochori in the Greek island of Crete.
A Comparison of Combustor-Noise Models
NASA Technical Reports Server (NTRS)
Hultgren, Lennart, S.
2012-01-01
The current status of combustor-noise prediction in the NASA Aircraft Noise Prediction Program (ANOPP) for current-generation (N) turbofan engines is summarized. Best methods for near-term updates are reviewed. Long-term needs and challenges for the N+1 through N+3 timeframe are discussed. This work was carried out under the NASA Fundamental Aeronautics Program, Subsonic Fixed Wing Project, Quiet Aircraft Subproject.
Effects of Nutrition Health Intervention on Pupils' Nutrition Knowledge and Eating Habits
ERIC Educational Resources Information Center
Raiha, Teija; Tossavainen, Kerttu; Turunen, Hannele; Enkenberg, Jorma; Kiviniemi, Vesa
2012-01-01
The purpose of this investigation was to evaluate the effects of nutrition health intervention on pupils' nutrition knowledge and eating habits from grade seven to grade nine. The study was part of the ENHPS (since 2008, Schools for Health in Europe (SHE)) program in Finland, and more specifically its sub-project titled "From Puijo to the…
Shifting Ontologies of a Serious Game and Its Relationships with English Education for Beginners
ERIC Educational Resources Information Center
Hansbol, MIkala; Meyer, Bente
2011-01-01
This article takes as its point of departure a language project which is a subproject under the larger ongoing (2007-2011) research project Serious Games on a Global Market Place. The language project follows how the virtual universe known as Mingoville (http://www.mingoville.com) becomes an actor in English education for beginners. The virtual…
Pupils' Views on an ICT-Based Learning Environment in Health Learning
ERIC Educational Resources Information Center
Räihä, Teija; Tossavainen, Kerttu; Enkenberg, Jorma; Turunen, Hannele
2014-01-01
This paper presents a study that examined pupils' views on an ICT-based learning environment in health learning. The study was a part of the wider European Network of Health Promoting Schools programme (ENHPS; since 2008, Schools for Health in Europe, SHE) in Finland, and particularly its sub-project, From Puijo to the World with Health Lunch,…
Gendered Subjective Theologies: Dutch Teenage Girls and Boys on the Role of Religion in Their Life
ERIC Educational Resources Information Center
ter Avest, Ina; Jozsa, Dan-Paul; Knauth, Thorsten
2010-01-01
In this article about the Dutch contribution to the REDCo sub-project on the role of gender, related to religion in/and school, the authors present the characteristics in the answers girls and boys, respectively gave to their questionnaires. Qualitative as well as quantitative methods were used in this research project. The research findings show…
Toxic contaminants are one of the most pressing environmental concerns in the Lake Superior Basin. The "Binational Program to Protect and Restore the Lake Superior Basin," a U.S. and Canadian governmental effort established to address this concern, has initially identified nine c...
Takala, A; Korhonen-Yrjänheikki, K
2013-12-01
The key stakeholders of the Finnish engineering education collaborated during 2006-09 to reform the system of education, to face the challenges of the changing business environment and to create a national strategy for the Finnish engineering education. The work process was carried out using participatory work methods. Impacts of sustainable development (SD) on engineering education were analysed in one of the subprojects. In addition to participatory workshops, the core part of the work on SD consisted of a research with more than 60 interviews and an extensive literature survey. This paper discusses the results of the research and the work process of the Collaboration Group in the subproject of SD. It is suggested that enhancing systematic dialogue among key stakeholders using participatory work methods is crucial in increasing motivation and commitment in incorporating SD in engineering education. Development of the context of learning is essential for improving skills of engineering graduates in some of the key abilities related to SD: systemic- and life-cycle thinking, ethical understanding, collaborative learning and critical reflection skills. This requires changing of the educational paradigm from teacher-centred to learner-centred applying problem- and project-oriented active learning methods.
Härter, Martin; Heddaeus, Daniela; Steinmann, Maya; Schreiber, Robert; Brettschneider, Christian; König, Hans-Helmut; Watzke, Birgit
2015-04-01
Depression is one of the most widespread mental disorders in Germany and causes a great suffering and involves high costs. Guidelines recommend stepped and interdisciplinary collaborative care models for the treatment of depression. Stepped and collaborative care models are described regarding their efficacy and cost-effectiveness. A current model project within the Hamburg Network for Mental Health exemplifies how guideline-based stepped diagnostics and treatment incorporating innovative low-intensity interventions are implemented by a large network of health care professionals and clinics. An accompanying evaluation using a cluster randomized controlled design assesses depressive symptom reduction and cost-effectiveness for patients treated within "Health Network Depression" ("Gesundheitsnetz Depression", a subproject of psychenet.de) compared with patients treated in routine care. Over 90 partners from inpatient and outpatient treatment have been successfully involved in recruiting over 600 patients within the stepped care model. Communication in the network was greatly facilitated by the use of an innovative online tool for the supply and reservation of treatment capacities. The participating professionals profit from the improved infrastructure and the implementation of advanced training and quality circle work. New treatment models can greatly improve the treatment of depression owing to their explicit reference to guidelines, the establishment of algorithms for diagnostics and treatment, the integration of practices and clinics, in addition to the implementation of low-intensity treatment alternatives. These models could promote the development of a disease management program for depression.
Carr, Lucas J; Mahar, Matthew T
2012-01-01
Purpose. To examine the accuracy of intensity and inclinometer output of three physical activity monitors during various sedentary and light-intensity activities. Methods. Thirty-six participants wore three physical activity monitors (ActiGraph GT1M, ActiGraph GT3X+, and StepWatch) while completing sedentary (lying, sitting watching television, sitting using computer, and standing still) light (walking 1.0 mph, pedaling 7.0 mph, pedaling 15.0 mph) intensity activities under controlled settings. Accuracy for correctly categorizing intensity was assessed for each monitor and threshold. Accuracy of the GT3X+ inclinometer function (GT3X+Incl) for correctly identifying anatomical position was also assessed. Percentage agreement between direct observation and the monitor recorded time spent in sedentary behavior and light intensity was examined. Results. All monitors using all thresholds accurately identified over 80% of sedentary behaviors and 60% of light-intensity walking time based on intensity output. The StepWatch was the most accurate in detecting pedaling time but unable to detect pedal workload. The GT3X+Incl accurately identified anatomical position during 70% of all activities but demonstrated limitations in discriminating between activities of differing intensity. Conclusions. Our findings suggest that all three monitors accurately measure most sedentary and light-intensity activities although choice of monitors should be based on study-specific needs.
Timber Mountain Precipitation Monitoring Station
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyles, Brad; McCurdy, Greg; Chapman, Jenny
2012-01-01
A precipitation monitoring station was placed on the west flank of Timber Mountain during the year 2010. It is located in an isolated highland area near the western border of the Nevada National Security Site (NNSS), south of Pahute Mesa. The cost of the equipment, permitting, and installation was provided by the Environmental Monitoring Systems Initiative (EMSI) project. Data collection, analysis, and maintenance of the station during fiscal year 2011 was funded by the U.S. Department of Energy, National Nuclear Security Administration, Nevada Site Office Environmental Restoration, Soils Activity. The station is located near the western headwaters of Forty Milemore » Wash on the Nevada Test and Training Range (NTTR). Overland flows from precipitation events that occur in the Timber Mountain high elevation area cross several of the contaminated Soils project CAU (Corrective Action Unit) sites located in the Forty Mile Wash watershed. Rain-on-snow events in the early winter and spring around Timber Mountain have contributed to several significant flow events in Forty Mile Wash. The data from the new precipitation gauge at Timber Mountain will provide important information for determining runoff response to precipitation events in this area of the NNSS. Timber Mountain is also a groundwater recharge area, and estimation of recharge from precipitation was important for the EMSI project in determining groundwater flowpaths and designing effective groundwater monitoring for Yucca Mountain. Recharge estimation additionally provides benefit to the Underground Test Area Sub-project analysis of groundwater flow direction and velocity from nuclear test areas on Pahute Mesa. Additionally, this site provides data that has been used during wild fire events and provided a singular monitoring location of the extreme precipitation events during December 2010 (see data section for more details). This letter report provides a summary of the site location, equipment, and data collected in fiscal year 2011.« less
Ricci, Joseph A; Vargas, Christina R; Ho, Olivia A; Lin, Samuel J; Tobias, Adam M; Lee, Bernard T
2017-07-01
Postoperative free flap care has historically required intensive monitoring for 24 hours in an intensive care unit. Continuous monitoring with tissue oximetry has allowed earlier detection of vascular compromise, decreasing flap loss and improving salvage. This study aims to identify whether a fast-track postoperative paradigm can be safely used with tissue oximetry to decrease intensive monitoring and costs. All consecutive microsurgical breast reconstructions performed at a single institution were reviewed (2008-2014) and cases requiring return to the operating room were identified. Data evaluated included patient demographics, the take back time course, and complications of flap loss and salvage. A cost-benefit analysis was performed to analyse the utility of a postoperative intensive monitoring setting. There were 900 flaps performed and 32 required an unplanned return to the operating room. There were 16 flaps that required a reexploration within the first 24 hours; the standard length of intensive unit monitoring. After 4 hours, there were 7 flaps (44%) detected by tissue oximetry for reexploration. After 15 hours of intensive monitoring postoperatively, cost analysis revealed that the majority (15/16; 94%) of failing flaps had been identified and the cost of identifying each subsequent failing flap exceeded the cost of another hour of intensive monitoring. The postoperative paradigm for microsurgical flaps has historically required intensive unit monitoring. Using tissue oximetry, a fast-track pathway can reduce time spent in an intensive monitoring setting from 24 to 15 hours with significant cost savings and minimal risk of missing a failing free flap.
Ultrafast Dynamics of Energetic Materials
2014-01-23
redistributed in condensed-phase materials. In this subproject we developed a technique termed three-dimensional IR- Raman spectroscopy that allowed us to...Fang, 2011, “The distribution of local enhancement factors in surface enhanced Raman -active substrates and the vibrational dynamics in the liquid phase...3. (invited) “Vibrational energy and molecular thermometers in liquids: Ultrafast IR- Raman spectroscopy”, Brandt C. Pein and Dana D. Dlott, To
Perception for Outdoor Navigation. First Year Report
1990-12-01
year , Crisman finished her thesis on SCARF [3]. This entailed three new research initiatives: intersection detection, analysis of performance on Warp...publications and personnel, then provide further detail on several of our subprojects. During the past year , this contract has supported research on ...integrated mobile robots. We overview our efforts for the year , and list our publirations and personnel, then provide further detail on several of our
NASA Astrophysics Data System (ADS)
Leclercq, Sylvain; Lidbury, David; Van Dyck, Steven; Moinereau, Dominique; Alamo, Ana; Mazouzi, Abdou Al
2010-11-01
In nuclear power plants, materials may undergo degradation due to severe irradiation conditions that may limit their operational life. Utilities that operate these reactors need to quantify the ageing and the potential degradations of some essential structures of the power plant to ensure safe and reliable plant operation. So far, the material databases needed to take account of these degradations in the design and safe operation of installations mainly rely on long-term irradiation programs in test reactors as well as on mechanical or corrosion testing in specialized hot cells. Continuous progress in the physical understanding of the phenomena involved in irradiation damage and continuous progress in computer sciences have now made possible the development of multi-scale numerical tools able to simulate the effects of irradiation on materials microstructure. A first step towards this goal has been successfully reached through the development of the RPV-2 and Toughness Module numerical tools by the scientific community created around the FP6 PERFECT project. These tools allow to simulate irradiation effects on the constitutive behaviour of the reactor pressure vessel low alloy steel, and also on its failure properties. Relying on the existing PERFECT Roadmap, the 4 years Collaborative Project PERFORM 60 has mainly for objective to develop multi-scale tools aimed at predicting the combined effects of irradiation and corrosion on internals (austenitic stainless steels) and also to improve existing ones on RPV (bainitic steels). PERFORM 60 is based on two technical sub-projects: (i) RPV and (ii) internals. In addition to these technical sub-projects, the Users' Group and Training sub-project shall allow representatives of constructors, utilities, research organizations… from Europe, USA and Japan to receive the information and training to get their own appraisal on limits and potentialities of the developed tools. An important effort will also be made to teach young researchers in the field of materials' degradation. PERFORM 60 has officially started on March 1st, 2009 with 20 European organizations and Universities involved in the nuclear field.
Benefits Analysis of Smart Grid Projects. White paper, 2014-2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marnay, Chris; Liu, Liping; Yu, JianCheng
Smart grids are rolling out internationally, with the United States (U.S.) nearing completion of a significant USD4-plus-billion federal program funded under the American Recovery and Reinvestment Act (ARRA-2009). The emergence of smart grids is widespread across developed countries. Multiple approaches to analyzing the benefits of smart grids have emerged. The goals of this white paper are to review these approaches and analyze examples of each to highlight their differences, advantages, and disadvantages. This work was conducted under the auspices of a joint U.S.-China research effort, the Climate Change Working Group (CCWG) Implementation Plan, Smart Grid. We present comparative benefits assessmentsmore » (BAs) of smart grid demonstrations in the U.S. and China along with a BA of a pilot project in Europe. In the U.S., we assess projects at two sites: (1) the University of California, Irvine campus (UCI), which consists of two distinct demonstrations: Southern California Edison’s (SCE) Irvine Smart Grid Demonstration Project (ISGD) and the UCI campus itself; and (2) the Navy Yard (TNY) area in Philadelphia, which has been repurposed as a mixed commercial-industrial, and possibly residential, development. In China, we cover several smart-grid aspects of the Sino-Singapore Tianjin Eco-city (TEC) and the Shenzhen Bay Technology and Ecology City (B-TEC). In Europe, we look at a BA of a pilot smart grid project in the Malagrotta area west of Rome, Italy, contributed by the Joint Research Centre (JRC) of the European Commission. The Irvine sub-project BAs use the U.S. Department of Energy (U.S. DOE) Smart Grid Computational Tool (SGCT), which is built on methods developed by the Electric Power Research Institute (EPRI). The TEC sub-project BAs apply Smart Grid Multi-Criteria Analysis (SG-MCA) developed by the State Grid Corporation of China (SGCC) based on the analytic hierarchy process (AHP) with fuzzy logic. The B-TEC and TNY sub-project BAs are evaluated using new approaches developed by those project teams. JRC has adopted an approach similar to EPRI’s but tailored to the Malagrotta distribution grid.« less
United States Air Force Statistical Digest, Fiscal Year 1959. Fourteenth Edition
1959-09-30
Support Forces for fiscal year 1959 consist of Air Refueling; Strategic Support; Airborne Early Warning and Control; Radar Evaluation ;.He11cop~er...missions. (EI) Test: Aircraft assigned to evaluate the aircraft and/or its components installed as standard equipment. (EH) Test Support: Aircraft... consumables under two AF-GEN sub-projects: PROJECT SEAWEED and PROJECT NIGHT LIFE & FLYAWAY KITS. Also included in this section is data on ammunition
TWRS Retrieval and Storage Mission and Immobilized Low Activity Waste (ILAW) Disposal Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
BURBANK, D.A.
This project plan has a twofold purpose. First, it provides a waste stream project plan specific to the River Protection Project (RPP) (formerly the Tank Waste Remediation System [TWRS] Project) Immobilized Low-Activity Waste (LAW) Disposal Subproject for the Washington State Department of Ecology (Ecology) that meets the requirements of Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-90-01 (Ecology et al. 1994) and is consistent with the project plan content guidelines found in Section 11.5 of the Tri-Party Agreement action plan (Ecology et al. 1998). Second, it provides an upper tier document that can be used as themore » basis for future subproject line-item construction management plans. The planning elements for the construction management plans are derived from applicable U.S. Department of Energy (DOE) planning guidance documents (DOE Orders 4700.1 [DOE 1992] and 430.1 [DOE 1995a]). The format and content of this project plan are designed to accommodate the requirements mentioned by the Tri-Party Agreement and the DOE orders. A cross-check matrix is provided in Appendix A to explain where in the plan project planning elements required by Section 11.5 of the Tri-Party Agreement are addressed.« less
NASA Astrophysics Data System (ADS)
Liu, C.-M.; Chen, I.-C.
2012-04-01
MEEP (Marine Education Enhancement Project) is a four-year pioneering project (Aug. 2008 to Jul. 2011) supported by Ministry of Education of Taiwan for the sake of spreading and deepening the ocean-related knowledge to the public as well as students at all universities and schools. MEEP covers several sub-projects which include the academic courses for college students either with or without marine background, the career training for students interested in ocean-related industries and shipbuilding, and the textbook editing for students from 6 to 18 years old. Among these sub-projects, the last one may be the most important because in Taiwan professional books containing ocean knowledge for younger students are quite few in the past. To this end, last year the authors completed a textbook entitled as "Ocean science, technology and history" suitable for students at junior high schools. Different from textbook used in universities and colleges, it requires more delicate means and vivid descriptions which are obviously beyond a professor's academic ability. Experiences the authors acquired in editing this textbook are represented herein. They include how the structure of chapters was chosen, how the figures for easy comprehension were painted, and how the difficult and hard sentences were translated to simple expressions.
NASA Astrophysics Data System (ADS)
Li, Lu-Ming; Zhu, Qian; Zhang, Zhi-Guo; Cai, Zhi-Min; Liao, Zhi-Jun; Hu, Zhen-Yan
2017-04-01
In this paper, a light intensity monitoring method based on FBG is proposed. The method establishes a light intensity monitoring model with cantilever beam structure and BP neural network algorithm, which is based on fiber grating sensing technology. The accuracy of the model can meet the requirements of engineering project and it can monitor light intensity in real time. The experimental results show that the method has good stability and high sensitivity.
Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter; Gregers Petersen, Hans; Benee Olsen, David; Berg, Ronan M G; Abrahamsen, Henrik; Wiinberg, Niels
2018-01-17
To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark. One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent home blood pressure monitoring and 24-hour ambulatory blood pressure monitoring. Mean day- and night-time systolic and diastolic 24-hour ambulatory blood pressure. Change in systolic and diastolic office blood pressure and change in cardiovascular risk profile. Of the patients, 515 (49%) were allocated to the usual group, and 533 (51%) to the intensive group. The reductions in day- and night-time 24-hour ambulatory blood pressure were similar (usual group: 4.6 ± 13.5/2.8 ± 82 mmHg; intensive group: 5.6 ± 13.0/3.5 ± 8.2 mmHg; P = 0.27/P = 0.20). Cardiovascular risk scores were reduced in both groups at follow-up, but more so in the intensive than in the usual group (P = 0.02). An intensive blood pressure monitoring strategy led to a similar blood pressure reduction to conventional monitoring. However, the intensive strategy appeared to improve patients' cardiovascular risk profile through other effects than a reduction of blood pressure. Clinical Trials NCT00244660. © The Author 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA UAS Integration into the NAS Project: Human Systems Integration
NASA Technical Reports Server (NTRS)
Shively, Jay
2016-01-01
This presentation provides an overview of the work the Human Systems Integration (HSI) sub-project has done on detect and avoid (DAA) displays while working on the UAS (Unmanned Aircraft System) Integration into the NAS project. The most recent simulation on DAA interoperability with Traffic Collision Avoidance System (TCAS) is discussed in the most detail. The relationship of the work to the larger UAS community and next steps are also detailed.
VizieR Online Data Catalog: OGLE-II. Cepheids in IC 1613 (Udalski+, 2001)
NASA Astrophysics Data System (ADS)
Udalski, A.; Wyrzykowski, L.; Pietrzynski, G.; Szewczyk, O.; Szymanski, M.; Kubiak, M.; Soszynski, I.; Zebrun, K.
2003-01-01
We present results of the search for Cepheids in the galaxy IC 1613 carried out as a sub-project of the OGLE-II microlensing survey. 138 Cepheids were found in the 14.2'x14.2' region in the center of the galaxy. We present light curves, VI photometry and basic data for all these objects, as well as color-magnitude diagram of the observed field. (4 data files).
Bisphosphonates in the Prevention of Post-Traumatic Osteoarthritis
2016-07-01
for grant PR120788P1 during the reporting period from 08/01/2015 to 07/30/2016 are noted. The animal surgery model (DMM) and drug-delivery methodology...and joint morphology appear very quickly following injury and are driven by very focal changes in chondrocyte health. In our animal model these...delivered ZA using an animal model) of the grant being performed within the partnering-PI’s lab (Price). This sub-project involves the pre-clinical testing
Study of compressed baryonic matter at FAIR: JINR participation
NASA Astrophysics Data System (ADS)
Derenovskaya, O.; Kurilkin, P.; Gusakov, Yu.; Ivanov, V.; Ladygin, V.; Ladygina, N.; Malakhov, A.; Peshekhonov, V.; Zinchenko, A.
2017-11-01
The scientific goal of the CBM (Compressed Baryonic Matter) experiment at FAIR (Darmstadt) is to explore the phase diagram of strongly interacting matter at highest baryon densities. The physics program of the CBM experiment is complimentary to the programs to be realized at MPD and BMN facilities at NICA and will start with beam derived by the SIS100 synchrotron. The results of JINR participation in the development of different sub-projects of the CBM experiment are presented.
1984-02-01
REQUIREMENT FOR CONSTRUCTION PROJECT: These buildings house electronic equipment, irreplaceable rocket motor design and performance records, a...consists of five subprojects which are to provide modern facilities designed for rocket motor production. These production efficient buildings will...replace facilities which were designed and built in 1930-1942 for artillery shell loading. Four of the sub- projects are for buildings while the fifth
ATD-1 Avionics Phase 2 Flight Test: Flight Test Operations and Saftey Report (FTOSR)
NASA Technical Reports Server (NTRS)
Boyle, Dan; Rein-Weston, Karl; Berckefeldt, Rick; Eggling, Helmuth; Stankiewicz, Craig; Silverman, George
2017-01-01
The Air Traffic Management Technology Demonstration-1 (ATD-1) is a major applied research and development activity of NASA's Airspace Operations and Safety Program (AOSP). The demonstration is the first of an envisioned series of Air Traffic Management (ATM) Technology Demonstration sub-projects that will demonstrate innovative NASA technologies that have attained a sufficient level of maturity to merit more in-depth research and evaluation at the system level in relevant environments.
2013-04-01
identifiable genetic etiology corresponding to a known single gene disorder, such as fragile X syndrome, or chromosomal rearrangements, including...DISTRIBUTION STATEMENT: X Approved for public release; distribution unlimited � Distribution limited to U.S. Government agencies...efficacy and tolerability 2006, 67, 407-414 Makkonen I, Riikonen R, Kokki H, Airaksinen MM. Kuikka JT. Serotonin and dopamine transporter binding in
Navy Civilian (Civil Service) Billet Costs--FY 1981.
1981-07-01
REPAIRItEN-- WACE LFADER (WE) (UNDISCOUNTED) INITIAL ANNUALLY YEARS IN LIFE CYCLE BILLET RECURRING GRD COST COST 1 5 10 15 20 5 318 32611 31013 128594 207215...and supporting each billet were established and are presented in 1-, 5-, 10-, 15-, and 20- year increments. DDI j ANඑ 1473 EDITION OF I OV...PAGSVfa Des ENotom.) FOREWORD This effort was conducted in support of Navy Decision Coordinating Paper ZI 170-PN, subproject Z1170-PN.05 (Reducing
Jin, Kui; Murugan, Raghavan; Sileanu, Florentina E; Foldes, Emily; Priyanka, Priyanka; Clermont, Gilles; Kellum, John A
2017-11-01
Urine output (UO) is a vital sign for critically ill patients, but standards for monitoring and reporting vary widely between ICUs. Careful monitoring of UO could lead to earlier recognition of acute kidney injury (AKI) and better fluid management. We sought to determine if the intensity of UO monitoring is associated with outcomes in patients with and those without AKI. This was a retrospective cohort study including 15,724 adults admitted to ICUs from 2000 to 2008. Intensive UO monitoring was defined as hourly recordings and no gaps > 3 hours for the first 48 hours after ICU admission. Intensive monitoring for UO was conducted in 4,049 patients (26%), and we found significantly higher rates of AKI (OR, 1.22; P < .001) in these patients. After adjustment for age and severity of illness, intensive UO monitoring was associated with improved survival but only among patients experiencing AKI. With or without AKI, patients with intensive monitoring also had less cumulative fluid volume (2.98 L vs 3.78 L; P < .001) and less fluid overload (2.49% vs 5.68%; P < .001) over the first 72 hours of ICU stay. In this large ICU population, intensive monitoring of UO was associated with improved detection of AKI and reduced 30-day mortality in patients experiencing AKI, as well as less fluid overload for all patients. Our results should help inform clinical decisions and ICU policy about frequency of monitoring of UO, especially for patients at high risk of AKI or fluid overload, or both. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
HOST turbine heat transfer subproject overview
NASA Technical Reports Server (NTRS)
Gladden, Herbert J.
1986-01-01
The experimental part of the turbine heat transfer subproject consists of six large experiments, which are highlighted in this overview, and three of somewhat more modest scope. One of the initial efforts was the stator airfoil heat transfer program. The non-film cooled and the showerhead film cooled data have already been reported. The gill region film cooling effort is currently underway. The investigation of secondary flows in a 90 deg curved duct, was completed. The first phase examined flows with a relatively thin inlet boundary layer and low free stream turbulence. The second phase studied a thicker inlet boundary layer and higher free stream turbulence. A comparison of analytical and experimental cross flow velocity vectors is shown for the 60 deg plane. Two experiments were also conducted in the high pressure facility. One examined full coverage film cooled vanes, and the other, advanced instrumentation. The other three large experimental efforts were conducted in a rotation reference frame. An experiment to obtain gas path airfoil heat transfer coefficients in the large, low speed turbine was completed. Single-stage data with both high and low-inlet turbulence were taken. The second phase examined a one and one-half stage turbine and focused on the second vane row. Under phase 3 aerodynamic quantities such as interrow time-averaged and rms values of velocity, flow angle, inlet turbulence, and surface pressure distribution were measured.
Environmental, political, and economic determinants of water quality monitoring in Europe
NASA Astrophysics Data System (ADS)
Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna
2010-11-01
Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.
Functions & Requirements for Debris Removal System Project A-2
DOE Office of Scientific and Technical Information (OSTI.GOV)
PRECECHTEL, D.R.
1999-12-29
This revision of the Functions and Requirements Document updates the approved Functions and Requirements for Debris Removal Subproject WHC-SD-SNF-FRD-009, Rev. 0. It has been revised in its entirety to reflect the current scope of work for Debris Removal as canisters and lids under the K Basin Projects work breakdown structure (WBS). In this revision the canisters and lids will be consider debris and a new set of Functions and Requirements have been developed to remove the canisters and lids from the basin.
NASA Technical Reports Server (NTRS)
Fern, Lisa Carolynn
2017-01-01
The primary activity for the UAS-NAS Human Systems Integration (HSI) sub-project in Phase 1 was support of RTCA Special Committee 228 Minimum Operational Performance Standards (MOPS). We provide data on the effect of various Detect and Avoid (DAA) display features with respect to pilot performance of the remain well clear function in order to determine the minimum requirements for DAA displays.
NASA Technical Reports Server (NTRS)
Johnson, M.; Label, K.; McCabe, J.; Powell, W.; Bolotin, G.; Kolawa, E.; Ng, T.; Hyde, D.
2007-01-01
Implementation of challenging Exploration Systems Missions Directorate objectives and strategies can be constrained by onboard computing capabilities and power efficiencies. The Radiation Hardened Electronics for Space Environments (RHESE) High Performance Processors for Space Environments project will address this challenge by significantly advancing the sustained throughput and processing efficiency of high-per$ormance radiation-hardened processors, targeting delivery of products by the end of FY12.
Extract and visualize geolocation from any text file
NASA Astrophysics Data System (ADS)
Boustani, M.
2015-12-01
There are variety of text file formats such as PDF, HTML and more which contains words about locations(countries, cities, regions and more). GeoParser developed as one of sub-projects under DARPA Memex to help finding any geolocation information crawled website data. It is a web application benefiting from Apache Tika to extract locations from any text file format and visualize geolocations on the map. https://github.com/MBoustani/GeoParserhttps://github.com/chrismattmann/tika-pythonhttp://www.darpa.mil/program/memex
2013-04-01
skills, (e) problems with generalization of previously acquired skills, (f) rigidity and resistance to change, (g) social and communication ...their known role in social behavior, communication , and stereotypic behavior results in identification of a structural component of functional deficits...neurons. These abnormalities may contribute to social and communication deficits, and restricted repetitive and stereotyped patterns of behavior. 3
Enabling Electric Propulsion for Flight
NASA Technical Reports Server (NTRS)
Ginn, Starr Renee
2015-01-01
Team Seedling project AFRC and LaRC 31ft distributed electric propulsion wing on truck bed up 75 miles per hour for coefficient of lift validation. Convergent Aeronautic Solutions project, sub-project Convergent Electric Propulsion Technologies AFRC, LaRC and GRC, re-winging a 4 passenger Tecnam aircraft with a 31ft distributed electric propulsion wing. Advanced Air Transport Technologies (Fixed Wing), Hybrid Electric Research Theme, developing a series hybrid ironbird and flight sim to study integration and performance challenges in preparation for a 1-2 MW flight project.
A Guide to the Microform Collections of the USMA (United States Military Academy) Library,
1983-01-01
array of material about the Manhattan Project and the atomic bombings of Hiroshima and Nagasaki; none of it was declassified until 1976. Foremost among...1946. The twenty-one page printed A Guide to the Manhattan Project : Official History and Documents, located on top of the metal cabinets in Room 212, is...organizational characteristics of the Manhattan Project . The seven succeeding books discussed the 49 various sub-projects of the effort, such as Book III
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, T.A., Fluor Daniel Hanford
1997-02-06
The Immobilized Low-Activity Waste Interim Storage subproject will provide storage capacity for immobilized low-activity waste product sold to the U.S. Department of Energy by the privatization contractor. This statement of work describes the work scope (encompassing definition of new installations and retrofit modifications to four existing grout vaults), to be performed by the Architect-Engineer, in preparation of a conceptual design for the Immobilized Low-Activity Waste Interim Storage Facility.
New and improved apparatus and method for monitoring the intensities of charged-particle beams
Varma, M.N.; Baum, J.W.
1981-01-16
Charged particle beam monitoring means are disposed in the path of a charged particle beam in an experimental device. The monitoring means comprise a beam monitoring component which is operable to prevent passage of a portion of beam, while concomitantly permitting passage of another portion thereof for incidence in an experimental chamber, and providing a signal (I/sub m/) indicative of the intensity of the beam portion which is not passed. Caibration means are disposed in the experimental chamber in the path of the said another beam portion and are operable to provide a signal (I/sub f/) indicative of the intensity thereof. Means are provided to determine the ratio (R) between said signals whereby, after suitable calibration, the calibration means may be removed from the experimental chamber and the intensity of the said another beam portion determined by monitoring of the monitoring means signal, per se.
R & D of a Gas-Filled RF Beam Profile Monitor for Intense Neutrino Beam Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yonehara, K.; Backfish, M.; Moretti, A.
We report the R&D of a novel radiation-robust hadron beam profile monitor based on a gas-filled RF cavity for intense neutrino beam experiments. An equivalent RF circuit model was made and simulated to optimize the RF parameter in a wide beam intensity range. As a result, the maximum acceptable beam intensity in the monitor is significantly increased by using a low-quality factor RF cavity. The plan for the demonstration test is set up to prepare for future neutrino beam experiments.
ERIC Educational Resources Information Center
Stanish, Heidi I.; Aucoin, Michael
2007-01-01
In order to gain physical fitness and health, exercise must be performed at a sufficient level of intensity. Exercise intensity can be monitored with rated perceived exertion (RPE) scales to promote safe and effective programming. The usefulness of the Children's OMNI Scale as a subjective measure of intensity for adults with intellectual…
The ZInEP Epidemiology Survey: background, design and methods.
Ajdacic-Gross, Vladeta; Müller, Mario; Rodgers, Stephanie; Warnke, Inge; Hengartner, Michael P; Landolt, Karin; Hagenmuller, Florence; Meier, Magali; Tse, Lee-Ting; Aleksandrowicz, Aleksandra; Passardi, Marco; Knöpfli, Daniel; Schönfelder, Herdis; Eisele, Jochen; Rüsch, Nicolas; Haker, Helene; Kawohl, Wolfram; Rössler, Wulf
2014-12-01
This article introduces the design, sampling, field procedures and instruments used in the ZInEP Epidemiology Survey. This survey is one of six ZInEP projects (Zürcher Impulsprogramm zur nachhaltigen Entwicklung der Psychiatrie, i.e. the "Zurich Program for Sustainable Development of Mental Health Services"). It parallels the longitudinal Zurich Study with a sample comparable in age and gender, and with similar methodology, including identical instruments. Thus, it is aimed at assessing the change of prevalence rates of common mental disorders and the use of professional help and psychiatric sevices. Moreover, the current survey widens the spectrum of topics by including sociopsychiatric questionnaires on stigma, stress related biological measures such as load and cortisol levels, electroencephalographic (EEG) and near-infrared spectroscopy (NIRS) examinations with various paradigms, and sociophysiological tests. The structure of the ZInEP Epidemiology Survey entails four subprojects: a short telephone screening using the SCL-27 (n of nearly 10,000), a comprehensive face-to-face interview based on the SPIKE (Structured Psychopathological Interview and Rating of the Social Consequences for Epidemiology: the main instrument of the Zurich Study) with a stratified sample (n = 1500), tests in the Center for Neurophysiology and Sociophysiology (n = 227), and a prospective study with up to three follow-up interviews and further measures (n = 157). In sum, the four subprojects of the ZInEP Epidemiology Survey deliver a large interdisciplinary database. Copyright © 2014 John Wiley & Sons, Ltd.
Turiano, Nicholas A.; Mroczek, Daniel K.; Moynihan, Jan; Chapman, Benjamin P.
2012-01-01
The current study investigated if the Big 5 personality traits predicted interleukin-6 (IL-6) levels in a national sample over the course of 5 years. In addition, interactions among the Big 5 were tested to provide a more accurate understanding of how personality traits may influence an inflammatory biomarker. Data included 1,054 participants in the Midlife Development in the U.S. (MIDUS) biomarkers subproject. The Big 5 personality traits were assessed in 2005-06 as part of the main MIDUS survey. Medication use, comorbid conditions, smoking behavior, alcohol use, body mass index, and serum levels of IL-6 were assessed in 2005-2009 as part of the biomarkers subproject. Linear regression analyses examined personality associations with IL-6. A significant Conscientiousness*Neuroticism interaction revealed that those high in both Conscientiousness and Neuroticism had lower circulating IL-6 levels than people with all other configurations of Conscientiousness and Neuroticism. Adjustment for health behaviors diminished the magnitude of this association but did not eliminate it, suggesting that lower comorbid conditions and obesity may partly explain the lower inflammation of those high in both Conscientiousness and Neuroticism. Our findings suggest, consistent with prior speculation, that average to higher levels of Neuroticism can in some cases be associated with health benefits—in this case when it is accompanied by high Conscientiousness. Using personality to identify those at risk may lead to greater personalization in the prevention and remediation of chronic inflammation. PMID:23123863
Turiano, Nicholas A; Mroczek, Daniel K; Moynihan, Jan; Chapman, Benjamin P
2013-02-01
The current study investigated if the Big 5 personality traits predicted interleukin-6 (IL-6) levels in a national sample over the course of 5years. In addition, interactions among the Big 5 were tested to provide a more accurate understanding of how personality traits may influence an inflammatory biomarker. Data included 1054 participants in the Midlife Development in the U.S. (MIDUS) biomarkers subproject. The Big 5 personality traits were assessed in 2005-2006 as part of the main MIDUS survey. Medication use, comorbid conditions, smoking behavior, alcohol use, body mass index, and serum levels of IL-6 were assessed in 2005-2009 as part of the biomarkers subproject. Linear regression analyses examined personality associations with IL-6. A significant Conscientiousness*Neuroticism interaction revealed that those high in both Conscientiousness and Neuroticism had lower circulating IL-6 levels than people with all other configurations of Conscientiousness and Neuroticism. Adjustment for health behaviors diminished the magnitude of this association but did not eliminate it, suggesting that lower comorbid conditions and obesity may partly explain the lower inflammation of those high in both Conscientiousness and Neuroticism. Our findings suggest, consistent with prior speculation, that average to higher levels of Neuroticism can in some cases be associated with health benefits - in this case when it is accompanied by high Conscientiousness. Using personality to identify those at risk may lead to greater personalization in the prevention and remediation of chronic inflammation. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Illing, Sebastian; Schuster, Mareike; Kadow, Christopher; Kröner, Igor; Richling, Andy; Grieger, Jens; Kruschke, Tim; Lang, Benjamin; Redl, Robert; Schartner, Thomas; Cubasch, Ulrich
2016-04-01
MiKlip is project for medium-term climate prediction funded by the Federal Ministry of Education and Research in Germany (BMBF) and aims to create a model system that is able provide reliable decadal climate forecasts. During the first project phase of MiKlip the sub-project INTEGRATION located at Freie Universität Berlin developed a framework for scientific infrastructures (FREVA). More information about FREVA can be found in EGU2016-13060. An instance of this framework is used as Central Evaluation System (CES) during the MiKlip project. Throughout the first project phase various sub-projects developed over 25 analysis tools - so called plugins - for the CES. The main focus of these plugins is on the evaluation and verification of decadal climate prediction data, but most plugins are not limited to this scope. They target a wide range of scientific questions. Starting from preprocessing tools like the "LeadtimeSelector", which creates lead-time dependent time-series from decadal hindcast sets, over tracking tools like the "Zykpak" plugin, which can objectively locate and track mid-latitude cyclones, to plugins like "MurCSS" or "SPECS", which calculate deterministic and probabilistic skill metrics. We also integrated some analyses from Model Evaluation Tools (MET), which was developed at NCAR. We will show the theoretical background, technical implementation strategies, and some interesting results of the evaluation of the MiKlip Prototype decadal prediction system for a selected set of these tools.
Apparatus and method for monitoring the intensities of charged particle beams
Varma, Matesh N.; Baum, John W.
1982-11-02
Charged particle beam monitoring means (40) are disposed in the path of a charged particle beam (44) in an experimental device (10). The monitoring means comprise a beam monitoring component (42) which is operable to prevent passage of a portion of beam (44), while concomitantly permitting passage of another portion thereof (46) for incidence in an experimental chamber (18), and providing a signal (I.sub.m) indicative of the intensity of the beam portion which is not passed. Calibration means (36) are disposed in the experimental chamber in the path of the said another beam portion and are operable to provide a signal (I.sub.f) indicative of the intensity thereof. Means (41 and 43) are provided to determine the ratio (R) between said signals whereby, after suitable calibration, the calibration means may be removed from the experimental chamber and the intensity of the said another beam portion determined by monitoring of the monitoring means signal, per se.
De Georgia, Michael A.; Kaffashi, Farhad; Jacono, Frank J.; Loparo, Kenneth A.
2015-01-01
There is a broad consensus that 21st century health care will require intensive use of information technology to acquire and analyze data and then manage and disseminate information extracted from the data. No area is more data intensive than the intensive care unit. While there have been major improvements in intensive care monitoring, the medical industry, for the most part, has not incorporated many of the advances in computer science, biomedical engineering, signal processing, and mathematics that many other industries have embraced. Acquiring, synchronizing, integrating, and analyzing patient data remain frustratingly difficult because of incompatibilities among monitoring equipment, proprietary limitations from industry, and the absence of standard data formatting. In this paper, we will review the history of computers in the intensive care unit along with commonly used monitoring and data acquisition systems, both those commercially available and those being developed for research purposes. PMID:25734185
De Georgia, Michael A; Kaffashi, Farhad; Jacono, Frank J; Loparo, Kenneth A
2015-01-01
There is a broad consensus that 21st century health care will require intensive use of information technology to acquire and analyze data and then manage and disseminate information extracted from the data. No area is more data intensive than the intensive care unit. While there have been major improvements in intensive care monitoring, the medical industry, for the most part, has not incorporated many of the advances in computer science, biomedical engineering, signal processing, and mathematics that many other industries have embraced. Acquiring, synchronizing, integrating, and analyzing patient data remain frustratingly difficult because of incompatibilities among monitoring equipment, proprietary limitations from industry, and the absence of standard data formatting. In this paper, we will review the history of computers in the intensive care unit along with commonly used monitoring and data acquisition systems, both those commercially available and those being developed for research purposes.
SFB 754 - Managing a large interdisciplinary collaborative research centre: what matters?
NASA Astrophysics Data System (ADS)
Schelten, Christiane; Antia, Avan; Braker, Gesche; Kamm, Ruth; Mehrtens, Hela
2016-04-01
The German Research Foundation (DFG) funds Collaborative Research Centres (CRCs - in German: Sonderforschungsbereiche SFBs) that are generally applied for by one university, but may also incorporate neighbouring universities or non-university research institutions. SFBs are crossing the boundaries of disciplines, as well as faculties, departments, institutions and institutes. The funding of an SFB can be up to 12 years (3 x 4 years). Kiel University and GEOMAR Helmholtz Centre for Ocean Research Kiel received funding for the SFB 754 'Climate-biogeochemical interactions in the tropical ocean' in 2008. Currently, the centre is in its third phase comprising 17 scientific subprojects, one outreach project, a central coordination and management subproject and a subproject covering the research expeditions with a total project budget of 12 Mio Euro. Around 100 scientists of interdisciplinary research fields (e.g. physical oceanography, micro-biology, palaeontology, chemistry, modelling) are actively involved. Besides generating high profile research, gender equality, early career support and data management are complementary goals of SFBs requested by the DFG. Within the SFB 754 the scientific coordination office is responsible for developing concepts and strategies to cover these additional requirements and over the past eight years the SFB 754 has been successful in setting up profound programmes and various measures. Some of the SFB 754 practices have been taken up by other projects, and hence allowed the SFB 754 to serve as a role model for 'best practice' within marine sciences in Kiel. A main reason for the success of the SFB 754 to work towards the additional goals set out in the DFGs SFB programme is that the project is well tied into existing structures and builds upon outstanding management expertise available in Kiel. Three examples are highlighted here: • young scientists programme (closely linked to a graduate school (Integrated School of Marine Sciences) and a postdoctoral network (Integrated Marine Postdoc Network) both set up by 'The Future Ocean', a project funded within the German Excellence Initiative • gender measures (close cooperation with the Central Office for Gender Equality, Diversity & Family at Kiel University) • data management (part of a joint GEOMAR data management group) Thus, a motivated and also creative coordination team interested in pioneer work is essential to manage a large interdisciplinary research community. Overall, networking, transparent management tools linked to active communication as well as fairness in processes such as the distribution of funds are basic prerequisites of trustful cooperation in large scientific consortia. (This presentation is linked to posters by Dr. Nina Bergmann, Dr. Gesche Braker, Dr. Ruth Kamm and Dr. Hela Mehrtens.)
NASA Technical Reports Server (NTRS)
Johnson, Charles W.
2011-01-01
The vision of the Unmanned Aircraft System (UAS) Integration in the National Airspace System (NAS) Project is "A global transportation system which allows routine access for all classes of UAS." The goal of the UAS Integration in the NAS Project is to "contribute capabilities that reduce technical barriers related to the safety and operational challenges associated with enabling routine UAS access to the NAS." This goal will be accomplished through a two-phased approach based on development of system-level integration of key concepts, technologies and/or procedures, and demonstrations of integrated capabilities in an operationally relevant environment. Phase 1 will take place the first two years of the Project and Phase 2 will take place the following three years. The Phase 1 and 2 technical objectives are: Phase 1: Developing a gap analysis between current state of the art and the Next Generation Air Transportation System (NextGen) UAS Concept of Operations . Validating the key technical areas identified by this Project . Conducting initial modeling, simulation, and flight testing activities . Completing Sub-project Phase 1 deliverables (spectrum requirements, comparative analysis of certification methodologies, etc.) and continue Phase 2 preparation (infrastructure, tools, etc.) Phase 2: Providing regulators with a methodology for developing airworthiness requirements for UAS, and data to support development of certifications standards and regulatory guidance . Providing systems-level, integrated testing of concepts and/or capabilities that address barriers to routine access to the NAS. Through simulation and flight testing, address issues including separation assurance, communications requirements, and human systems integration in operationally relevant environments. The UAS in the NAS Project will demonstrate solutions in specific technology areas, which will address operational/safety issues related to UAS access to the NAS. Since the resource allocation for this Project is limited ($150M over the five years), the focus is on reducing the technical barriers where NASA has unique capabilities. As a result, technical areas, such as Sense and Avoid (SAA) and beyond line of sight command and control will not be addressed. While these are critical barriers to UAS access, currently, there is a great deal of global effort being exercised to address these challenge areas. Instead, specific technology development in areas where there is certainty that NASA can advance the research to high technology readiness levels will be the Project's focus. Specific sub-projects include Separation Assurance, Human Systems Integration, Communications, Certification, and Integrated Test and Evaluation. Each sub-project will transfer technologies to relevant key stakeholders and decision makers through research transition teams, technology forums, or through other analogous means.
Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Thomas; Freund, Wolfgang; Boesenberg, Ulrike
Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, berylliummore » and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. In conclusion, the graphite detector can also be used as a beam position monitor although with rather coarse resolution.« less
Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors
Roth, Thomas; Freund, Wolfgang; Boesenberg, Ulrike; ...
2018-01-01
Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, berylliummore » and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. In conclusion, the graphite detector can also be used as a beam position monitor although with rather coarse resolution.« less
GRO: Black hole models for gamma ray bursts
NASA Technical Reports Server (NTRS)
Shaham, Jacob
1993-01-01
This grant deals with the production of gamma-ray bursts (GRB's) close to horizons of black holes (BH's), mainly via accretion of small chunks of matter onto extreme Kerr BH's. In the past year, we laid the ground work for actual calculations close to Kerr BH's. Because of technical reasons, actual work has only started very recently. Following the detailed list of research subprojects as per our original proposal, we have performed research in the following areas: spectrum calculation; burst dynamics; tidal capture and primordial cloud collapse; halo density profile; and capture of other objects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breckenridge, W.J.; Tester, J.R.
1962-01-01
Progress is reported for studies of environmental and radiation effects on three species of toads, Bufo americanus, B. cognatus and B. hemiophrys. Controlled surival tests in which tadpoles of B. americanus and B. hemiophrys were subjected to physical and chemical extremes indicated that B. hemiophrys is more resistant than B. americanus. The status of the subprojects on factors influencing toad survival during hibernatlon and irradistion of dormant toads is outlined. A soil simulator was built for studying the burrowing behavior of toads. (D.L.C.)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmeide, Katja; Fritsch, Katharina; Lippold, Holger
2016-02-29
The objective of this project was to study the influence of increased salinities on interaction processes in the system radionuclide – organics – clay – aquifer. For this, complexation, redox, sorption, and diffusion studies were performed under variation of the ionic strength (up to 4 mol kg -1) and the background electrolyte (NaCl, CaCl 2, MgCl 2).
Enabling Electric Propulsion for Flight
NASA Technical Reports Server (NTRS)
Ginn, Starr
2014-01-01
Description of current ARMD projects; Team Seedling project AFRC and LaRC 31ft distributed electric propulsion wing on truck bed up 75 miles per hour for coefficient of lift validation. Convergent Aeronautic Solutions project (new ARMD reorg), sub-project Convergent Electric Propulsion Technologies AFRC, LaRC and GRC, re-winging a 4 passenger Tecnam aircraft with a 31ft distributed electric propulsion wing. Advanced Air Transport Technologies (Fixed Wing), Hybrid Electric Research Theme, developing a series hybrid ironbird and flight sim to study integration and performance challenges in preparation for a 1-2 MW flight project.
Validity of physical activity monitors for assessing lower intensity activity in adults.
Calabró, M Andrés; Lee, Jung-Min; Saint-Maurice, Pedro F; Yoo, Hyelim; Welk, Gregory J
2014-09-28
Accelerometers can provide accurate estimates of moderate-to-vigorous physical activity (MVPA). However, one of the limitations of these instruments is the inability to capture light activity within an acceptable range of error. The purpose of the present study was to determine the validity of different activity monitors for estimating energy expenditure (EE) of light intensity, semi-structured activities. Forty healthy participants wore a SenseWear Pro3 Armband (SWA, v.6.1), the SenseWear Mini, the Actiheart, ActiGraph, and ActivPAL monitors, while being monitored with a portable indirect calorimetry (IC). Participants engaged in a variety of low intensity activities but no formalized scripts or protocols were used during these periods. The Mini and SWA overestimated total EE on average by 1.0% and 4.0%, respectively, while the AH, the GT3X, and the AP underestimated total EE on average by 7.8%, 25.5%, and 22.2%, respectively. The pattern-recognition monitors yielded non-significant differences in EE estimates during the semi-structured period (p = 0.66, p = 0.27, and p = 0.21 for the Mini, SWA, and AH, respectively). The SenseWear Mini provided more accurate estimates of EE during light to moderate intensity semi-structured activities compared to other activity monitors. This monitor should be considered when there is interest in tracking low intensity activities in groups of individuals.
Jahn, I; Gansefort, D; Kindler-Röhrborn, A; Pfleiderer, B
2014-09-01
It is considered general knowledge among physicians and epidemiologists that biological and social aspects associated with being male or female have a strong influence on health and disease. Integrating these aspects into research is necessary to counteract the problems--including ethical problems--resulting from a different evidence basis for men and women. From January 2011 to June 2014 the Federal Ministry of Education and Research supported the network "Sex-/Gender-Sensitive Research in Epidemiology, Neuroscience and Genetics/Cancer Research" with three subprojects, which aimed to promote gender-sensitive research practices. The concepts and results are presented in this article. The subproject gathered data (literature analyses, questionnaires) and offered programs for young scientists. Experiences and results were collected and generalized, for instance, in the form of definitions of terms. 50 young scientists have taken part in the training program, identifying associations and barriers in sex-/gender-sensitive research. Among others, a working definition for "sex-/gender-sensitive research" was developed, as well as definitions for the terms "sex-specific" (for biological characteristics that are specific to men or women) and "sex-/gender-dependent" or "sex-/gender-associated" (for biological and social factors, for which the extent of occurrence differs between the sexes). The concepts realized by the network are well suited to stimulate further development and discussions. The definition of terms is an important base for a productive and high-yielding interdisciplinary collaboration.
Leue, Anja; Weber, Bernd; Beauducel, André
2014-01-01
Conflict monitoring is a process of stimulus evaluation and a pre-requisite for subsequent recruitment of cognitive control and behavioral adaptations. This study investigated how experimentally manipulated working-memory-related cognitive demand and aversive reinforcement modulate individual differences of conflict monitoring intensity and behavioral adjustments. Individual differences were assessed by means of an anxiety-related trait dimension (trait-BIS) and by means of reasoning abilities—a core determinant of intelligence. Moreover, we investigated the special role of verbal reasoning ability and figural reasoning ability for the modulation of the conflict monitoring intensity. Ninety participants performed a go/nogo task with four conditions each comprising a combination of low vs. high working-memory-related cognitive demand and low vs. high aversive reinforcement. No effect of aversive reinforcement was observed for the N2 amplitude. The fronto-central nogo N2 amplitude was more pronounced for high demand vs. low demand suggesting that cognitive demand served as an aversive costly event. Higher total reasoning abilities were associated with more intense conflict monitoring and shorter response times with increasing aversive reinforcement (defined as verbal error-feedback vs. monetary loss). Individuals with higher trait-BIS scores demonstrated a more intense conflict monitoring even in conditions with low aversive reinforcement and also a more cautious responding (i.e., response times slowing) with increasing aversive reinforcement indicating a focus on negative feedback prevention. The findings provide evidence for the conflict monitoring theory and suggest that working-memory-related demand overrules the impact of aversive reinforcement on conflict monitoring intensity. Reasoning abilities and anxiety-related traits go along with an intensification of conflict monitoring but differences in the flexibility of behavioral adjustment. PMID:24782739
ERIC Educational Resources Information Center
Ennis, Robin Parks; Lane, Kathleen Lynne; Oakes, Wendy Peia
2018-01-01
Self-monitoring is a low-intensity strategy teachers can use to support instruction in classrooms across the grade span in various instructional settings and content areas. This study extended the knowledge base by examining the effectiveness of self-monitoring through a systematic replication with three students with specific learning…
Drinking water treatment for a rural karst region in Indonesia
NASA Astrophysics Data System (ADS)
Matthies, K.; Schott, C.; Anggraini, A. K.; Silva, A.; Diedel, R.; Mühlebach, H.; Fuchs, S.; Obst, U.; Brenner-Weiss, G.
2016-09-01
An interdisciplinary German-Indonesian joint research project on Integrated Water Resources Management (IWRM) focused on the development and exemplary implementation of adapted technologies to improve the water supply situation in a model karst region in southern Java. The project involving 19 sub-projects covers exploration of water resources, water extraction, distribution as well as water quality assurance, and waste water treatment. For the water quality assurance, an appropriate and sustainable drinking water treatment concept was developed and exemplarily implemented. Monitoring results showed that the main quality issue was the contamination with hygienically relevant bacteria. Based on the gained results, a water treatment concept was developed consisting of a central sand filtration prior to the distribution network, a semi-central hygienization where large water volumes are needed to remove bacteria deriving from water distribution and a final point-of-use water treatment. This paper focuses on the development of a central sand filtration plant and some first analysis for the development of a recipe for the local production of ceramic filters for household water treatment. The first results show that arsenic and manganese are leaching from the filters made of local raw material. Though discarding the first, filtrates should be sufficient to reduce arsenic and manganese concentration effectively. Moreover, hydraulic conductivities of filter pots made of 40 % pore-forming agents are presented and discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thurman-Keup, R.; Lorman, E.; Meyer, T.
2005-05-01
This paper discusses the implementation of abort gap beam intensity monitoring at the Tevatron collider at Fermilab. There are two somewhat independent monitors which measure the intensity of the synchrotron light emitted by particles in the abort gaps. One system uses a gated Photomultiplier Tube (PMT) to measure the light intensity, and the other system uses a single lens telescope, gated image intensifier, and Charge Injection Device (CID) camera to image the beam.
NASA Technical Reports Server (NTRS)
Fern, Lisa; Rorie, Conrad; Shively, Jay
2015-01-01
This presentation provides an overview of the work the Human Systems Integration (HSI) sub-project has done on detect and avoid (DAA) displays while working on the UAS Integration into the NAS project. Much of the work has been used to support the ongoing development of minimum operational performance standards (MOPS) for UAS by RTCA Special Committee 228. The design and results of three different human-in-the-loop simulations are discussed, with particular emphasis on the role of the UAS pilot in the Self Separation Timeline.
NASA Technical Reports Server (NTRS)
Levine, S. R.
1982-01-01
A first-cut integrated environmental attack life prediction methodology for hot section components is addressed. The HOST program is concerned with oxidation and hot corrosion attack of metallic coatings as well as their degradation by interdiffusion with the substrate. The effects of the environment and coatings on creep/fatigue behavior are being addressed through a joint effort with the Fatigue sub-project. An initial effort will attempt to scope the problem of thermal barrier coating life prediction. Verification of models will be carried out through benchmark rig tests including a 4 atm. replaceable blade turbine and a 50 atm. pressurized burner rig.
Evaluation of spatial, radiometric and spectral Thematic Mapper performance for coastal studies
NASA Technical Reports Server (NTRS)
Klemas, V.; Ackleson, S. G.; Hardisky, M. A.
1985-01-01
On 31 March 1983, the University of Delaware's Center for Remote Sensing initiated a study to evaluate the spatial, radiometric and spectral performance of the LANDSAT Thematic Mapper for coastal and estuarine studies. The investigation was supported by Contract NAS5-27580 from the NASA Goddard Space Flight Center. The research was divided into three major subprojects: (1) a comparison of LANDSAT TM to MSS imagery for detecting submerged aquatic vegetation in Chesapeake Bay; (2) remote sensing of submerged aquatic vegetation - a radiative transfer approach; and (3) remote sensing of coastal wetland biomass using Thematic Mapper wavebands.
Improving IMRT delivery efficiency using intensity limits during inverse planning.
Coselmon, Martha M; Moran, Jean M; Radawski, Jeffrey D; Fraass, Benedick A
2005-05-01
Inverse planned intensity modulated radiotherapy (IMRT) fields can be highly modulated due to the large number of degrees of freedom involved in the inverse planning process. Additional modulation typically results in a more optimal plan, although the clinical rewards may be small or offset by additional delivery complexity and/or increased dose from transmission and leakage. Increasing modulation decreases delivery efficiency, and may lead to plans that are more sensitive to geometrical uncertainties. The purpose of this work is to assess the use of maximum intensity limits in inverse IMRT planning as a simple way to increase delivery efficiency without significantly affecting plan quality. Nine clinical cases (three each for brain, prostate, and head/neck) were used to evaluate advantages and disadvantages of limiting maximum intensity to increase delivery efficiency. IMRT plans were generated using in-house protocol-based constraints and objectives for the brain and head/neck, and RTOG 9406 dose volume objectives in the prostate. Each case was optimized at a series of maximum intensity ratios (the product of the maximum intensity and the number of beams divided by the prescribed dose to the target volume), and evaluated in terms of clinical metrics, dose-volume histograms, monitor units (MU) required per fraction (SMLC and DMLC delivery), and intensity map variation (a measure of the beam modulation). In each site tested, it was possible to reduce total monitor units by constraining the maximum allowed intensity without compromising the clinical acceptability of the plan. Monitor unit reductions up to 38% were observed for SMLC delivery, while reductions up to 29% were achieved for DMLC delivery. In general, complicated geometries saw a smaller reduction in monitor units for both delivery types, although DMLC delivery required significantly more monitor units in all cases. Constraining the maximum intensity in an inverse IMRT plan is a simple way to improve delivery efficiency without compromising plan objectives.
De Block, Christophe; Manuel-y-Keenoy, Begoña; Rogiers, Peter; Jorens, Philippe; Van Gaal, Luc
2008-08-01
Stress hyperglycemia recently became a major therapeutic target in the Intensive Care Unit (ICU) since it occurs in most critically ill patients and is associated with adverse outcome, including increased mortality. Intensive insulin therapy to achieve normoglycemia may reduce mortality, morbidity and the length of ICU and in-hospital stay. However, obtaining normoglycemia requires extensive efforts from the medical staff, including frequent glucose monitoring and adjustment of insulin dose. Current insulin titration is based upon discrete glucose measurements, which may miss fast changes in glycemia and which does not give a full picture of overall glycemic control. Recent evidence suggests that continuous monitoring of glucose levels may help to signal glycemic excursions and eventually to optimize insulin titration in the ICU. In this review we will summarise monitoring and treatment strategies to achieve normoglycemia in the ICU, with special emphasis on the possible advantages of continuous glucose monitoring.
NASA Astrophysics Data System (ADS)
Tanaka, Takahiro; Kato, Masahiro; Saito, Norio; Owada, Shigeki; Tono, Kensuke; Yabashi, Makina; Ishikawa, Tetsuya
2018-06-01
This paper reports measurement of the absolute intensity of free-electron laser (FEL) and calibration of online intensity monitors for a brand-new FEL beamline BL1 at SPring-8 Angstrom Compact free-electron LAser (SACLA) in Japan. To measure the absolute intensity of FEL, we used a room-temperature calorimeter originally developed for FELs in the hard X-ray range. By using the calorimeter, we calibrated online intensity monitors of BL1, gas monitors (GMs), based on the photoionization of argon gas, in the photon energy range from 25 eV to 150 eV. A good correlation between signals obtained from the calorimeter and GMs was observed in the pulse energy range from 1 μJ to 100 μJ, where the upper limit is nearly equal to the maximum pulse energy at BL1. Moreover, the calibration result of the GMs, measured in terms of the spectral responsivity, demonstrates a characteristic photon-energy dependence owing to the occurrence of the Cooper minimum in the total ionization cross-section of argon gas. These results validate the feasibility of employing the room-temperature calorimeter in the measurement of absolute intensity of FELs over the specified photon energy range.
Ochagavía, A; Baigorri, F; Mesquida, J; Ayuela, J M; Ferrándiz, A; García, X; Monge, M I; Mateu, L; Sabatier, C; Clau-Terré, F; Vicho, R; Zapata, L; Maynar, J; Gil, A
2014-04-01
Hemodynamic monitoring offers valuable information on cardiovascular performance in the critically ill, and has become a fundamental tool in the diagnostic approach and in the therapy guidance of those patients presenting with tissue hypoperfusion. From introduction of the pulmonary artery catheter to the latest less invasive technologies, hemodynamic monitoring has been surrounded by many questions regarding its usefulness and its ultimate impact on patient prognosis. The Cardiological Intensive Care and CPR Working Group (GTCIC-RCP) of the Spanish Society of Intensive Care and Coronary Units (SEMICYUC) has recently impulsed the development of an updating series in hemodynamic monitoring. Now, a final series of recommendations are presented in order to analyze essential issues in hemodynamics, with the purpose of becoming a useful tool for residents and critical care practitioners involved in the daily management of critically ill patients. Copyright © 2013 Elsevier España, S.L. and SEMICYUC. All rights reserved.
Rock Burst Monitoring by Integrated Microseismic and Electromagnetic Radiation Methods
NASA Astrophysics Data System (ADS)
Li, Xuelong; Wang, Enyuan; Li, Zhonghui; Liu, Zhentang; Song, Dazhao; Qiu, Liming
2016-11-01
For this study, microseismic (MS) and electromagnetic radiation (EMR) monitoring systems were installed in a coal mine to monitor rock bursts. The MS system monitors coal or rock mass ruptures in the whole mine, whereas the EMR equipment monitors the coal or rock stress in a small area. By analysing the MS energy, number of MS events, and EMR intensity with respect to rock bursts, it has been shown that the energy and number of MS events present a "quiet period" 1-3 days before the rock burst. The data also show that the EMR intensity reaches a peak before the rock burst and this EMR intensity peak generally corresponds to the MS "quiet period". There is a positive correlation between stress and EMR intensity. Buckling failure of coal or rock depends on the rheological properties and occurs after the peak stress in the high-stress concentration areas in deep mines. The MS "quiet period" before the rock burst is caused by the heterogeneity of the coal and rock structures, the transfer of high stress into internal areas, locked patches, and self-organized criticality near the stress peak. This study increases our understanding of coal and rock instability in deep mines. Combining MS and EMR to monitor rock burst could improve prediction accuracy.
Rütten, Alfred; Frahsa, Annika; Abel, Thomas; Bergmann, Matthias; de Leeuw, Evelyne; Hunter, David; Jansen, Maria; King, Abby; Potvin, Louise
2017-09-08
Population health interventions tend to lack links to the emerging discourse on interactive knowledge production and exchange. This situation may limit both a better understanding of mechanisms that impact health lifestyles and the development of strategies for population level change. This paper introduces an integrated approach based on structure-agency theory in the context of 'social practice'. It investigates the mechanisms of co-production of active lifestyles by population groups, professionals, policymakers and researchers. It combines a whole system approach with an interactive knowledge-to-action strategy for developing and implementing active lifestyle interventions. A system model is outlined to describe and explain how social practices of selected groups co-produce active lifestyles. Four intervention models for promoting the co-production of active lifestyles through an interactive-knowledge-to-action approach are discussed. Examples from case studies of the German research network Capital4Health are used to illustrate, how intervention models might be operationalized in a real-world intervention. Five subprojects develop, implement and evaluate interventions across the life-course. Although subprojects differ with regard to settings and population groups involved, they all focus on the four key components of the system model. The paper contributes new strategies to address the intervention research challenge of sustainable change of inactive lifestyles. The interactive approach presented allows consideration of the specificities of settings and scientific contexts for manifold purposes. Further research remains needed on what a co-produced knowledge-to-action agenda would look like and what impact it might have for whole system change. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Mielck, Finn; Hass, H. Christian; Holler, Peter; Bartholomä, Alexander; Neumann, Andreas; Kröncke, Ingrid; Reimers, Hans-Christian; Capperucci, Ruggero
2016-04-01
The joint research project WIMO (Wissenschaftliche Monitoringkonzepte für die Deutsche Bucht/Scientific Monitoring Concepts for the German Bight, NE North Sea) aims at providing methods for detection and analysis of seabed habitats using modern remote sensing techniques. Our subproject focuses on hydroacoustic techniques in order to gain information about seafloor environments and sediment dynamics. In a timeframe of four years, several key areas in the German Bight were repeatedly observed using different hydroacoustic gear (i. e. sidescan sonars, single/multibeam echo sounders and sub-bottom profilers). In order to ground-truth the acoustic data, hundreds of grab samples and underwater videos were taken. With these techniques it is possible to distinguish between different seafloor habitats, which range from muddy to sandy seafloors (esp. near the barrier islands) to rugged or vegetated/populated reefs around Helgoland. The conducted monitoring program revealed seasonal changes regarding the abundance of the sand mason worm (Lanice conchilega) and the brittle star (Amphiora filiformis) as well as ongoing sedimentary processes driven by tidal currents and wind/storms. It was also possible to determine relationships between sediment characteristics and benthos in some key areas. An essential part of our project included a comparison between the datasets obtained with different hydroacoustic devices, configurations, and evaluation methods in the same study areas. The investigation reveals that there could be distinct differences in interpreting the data and hence in the determination of prevailing seafloor habitats, especially in very heterogeneous areas and at transition zones between the habitats. Therefore, it is recommended to employ more than one hydroacoustic system (preferably a singlebeam device combined with a wide-swath sonar system) synchronously during a survey in order to gain more reliable and detailed information about the seafloor environments. The results of this project study form an important contribution to ongoing and future projects, in particular with regard to the technical configuration of the sonar systems, the workflows concerning post-processing and validation of the hydroacoustic data as well as the monitoring concepts that were worked out. However, a full automation of these workflows is not feasible. For the time being, measurements, post-processing and data evaluation still need supervision and expert knowledge.
Mateo, Joaquim; Payen, Didier; Ghout, Idir; Vallée, Fabrice; Lescot, Thomas; Welschbillig, Stephane; Tazarourte, Karim; Azouvi, Philippe; Weiss, Jean-Jacques; Aegerter, Philippe; Vigué, Bernard
2017-01-01
We evaluated whether an integrated monitoring with systemic and specific monitoring affect mortality and disability in adults with severe traumatic brain injury (sTBI). Adults with severeTBI (Glasgow Coma Scale [GCS] ≤ 8) admitted alive in intensive care units (ICUs) were prospectively included. Primary endpoints were in-hospital 30-day mortality and extended Glasgow outcome score (GOSE) at 3 years. Association with the intensity of monitoring and outcome was studied by comparing a high level of monitoring (HLM) (systemic and ≥3 specific monitoring) and low level of monitoring (LLM) (systemic and 0-2 specific monitoring) and using inverse probability weighting procedure. 476 patients were included and IPW was used to improve the balance between the two groups of treatments (HLM/LMM). Overall hospital mortality (at 30 days) was 43%, being significantly lower in HLM than LLM group (27% vs. 53%: RR, 1.63: 95% CI: 1.23-2.15). The 14-day hospital mortality was also lower in the HLM group than expected, based upon the CRASH prediction model (35%). At 3 years, disability was not significantly different between the monitoring groups. After adjustment, HLM group improved short-term mortality but did not show any improvement in the 3-year outcome compared with LLM.
NASA Technical Reports Server (NTRS)
Cronin, A. G.; Delaney, J. R.
1973-01-01
The system is discussed which was developed to process digitized telemetry data from the intensity monitoring spectrometer flown on the Orbiting Geophysical Observatory (OGO-F) Satellite. Functional descriptions and operating instructions are included for each program in the system.
Swann, Don E.; Bucci, Melanie; Kuenzi, Amy J.; Alberti, Barbara N.; Schwalbe, Cecil R.; Halvorson, William L.; van Riper, Charles; Schwalbe, Cecil R.
2010-01-01
Long-term monitoring in national parks is essential to meet National Park Service and other important public goals. Terrestrial mammals are often proposed for monitoring because large mammals are of interest to visitors and small mammals are important as prey. However, traditional monitoring strategies for mammals are often too expensive and complex to sustain for long periods, particularly in small parks. To evaluate potential strategies for long-term monitoring in small parks, we conducted an intensive one-year inventory of terrestrial mammals at Coronado National Memorial, located in Arizona on the U.S.-Mexico international border, then continued less-intensive monitoring at the site for 7 additional years. During 1996-2003 we confirmed 44 species of terrestrial mammals. Most species (40) were detected in the intensive first year of the study, but we continued to detect new species in later years. Mark-recapture data on small mammals indicated large inter-annual fluctuations in population size, but no significant trend over the 7-year period. Issues associated with the international border affected monitoring efforts and increased sampling costs. Our study confirms that sustained annual monitoring of mammals is probably not feasible in small park units like Coronado. However, comparisons of our data with past studies provide insight into important changes in the mammal community since the 1970s, including an increase in abundance and diversity of grassland rodents. Our results suggest that intensive inventories every 10-20 years may be a valuable and cost-effective approach for detecting long-term trends in terrestrial mammal communities in small natural areas.
Operation of the intensity monitors in beam transport lines at Fermilab during Run II¹
Crisp, J.; Fellenz, B.; Fitzgerald, J.; ...
2011-10-06
The intensity of charged particle beams at Fermilab must be kept within pre-determined safety and operational envelopes in part by assuring all beam within a few percent has been transported from any source to destination. Beam instensity monitors with toroidial pickups provide such beam intensity measurements in the transport lines between accelerators at FNAL. With Run II, much effort was made to continually improve the resolution and accuracy of the system.
Practical Approaches to Prescribing Physical Activity and Monitoring Exercise Intensity.
Reed, Jennifer L; Pipe, Andrew L
2016-04-01
Regular physical activity helps to prevent heart disease, and reduces the risk of first or subsequent cardiovascular events. It is recommended that Canadian adults accumulate at least 150 minutes of moderate- to vigorous-intensity aerobic exercise per week, in bouts of 10 minutes or more, and perform muscle- and bone-strengthening activities at least 2 days per week. Individual exercise prescriptions can be developed using the frequency, intensity, time, and type principles. Increasing evidence suggests that high-intensity interval training is efficacious for a broad spectrum of heart health outcomes. Several practical approaches to prescribing and monitoring exercise intensity exist including: heart rate monitoring, the Borg rating of perceived exertion scale, the Talk Test, and, motion sensors. The Borg rating of perceived exertion scale matches a numerical value to an individual's perception of effort, and can also be used to estimate heart rate. The Talk Test, the level at which simple conversation is possible, can be used to monitor desired levels of moderate- to vigorous-intensity exercise. Motion sensors can provide users with practical and useful exercise training information to aid in meeting current exercise recommendations. These approaches can be used by the public, exercise scientists, and clinicians to easily and effectively guide physical activity in a variety of settings. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Peculiarities of cosmic ray modulation in the solar minimum 23/24
NASA Astrophysics Data System (ADS)
Alania, M. V.; Modzelewska, R.; Wawrzynczak, A.
2014-06-01
We study changes of the galactic cosmic ray (GCR) intensity for the ending period of the solar cycle 23 and the beginning of the solar cycle 24 using neutron monitors experimental data. We show that an increase of the GCR intensity in 2009 is generally related with decrease of the solar wind velocity U, the strength B of the interplanetary magnetic field (IMF), and the drift in negative (A < 0) polarity epoch. We present that temporal changes of rigidity dependence of the GCR intensity variation, before reaching maximum level in 2009 and after it, do not noticeably differ from each other. The rigidity spectrum of the GCR intensity variations calculated based on neutron monitors data (for rigidities > 10 GV) is hard in the minimum and near-minimum epoch. We do not recognize any nonordinary changes in the physical mechanism of modulation of the GCR intensity in the rigidity range of GCR particles to which neutron monitors respond. We compose 2-D nonstationary model of transport equation to describe variations of the GCR intensity for 1996-2012 including the A > 0 (1996-2001) and the A < 0 (2002-2012) periods; diffusion coefficient of cosmic rays for rigidity 10-15 GV is increased by 30% in 2009 (A < 0) comparing with 1996 (A > 0). We believe that the proposed model is relatively realistic, and obtained results are satisfactorily compatible with neutron monitors data.
Method and apparatus for optical temperature measurements
Angel, S.M.; Hirschfeld, T.B.
1986-04-22
A method and apparatus are provided for remotely monitoring temperature. Both method and apparatus employ a temperature probe material having an excitation-dependent emission line whose fluorescence intensity varies directly with temperature whenever excited by light having a first wavelength and whose fluorescence intensity varies inversely with temperature whenever excited by light having a second wavelength. Temperature is measured by alternatively illiminating the temperature probe material with light having the first wavelength and light having the second wavelength, monitoring the intensity of the successive emissions of the excitation-dependent emission line, and relating the intensity ratio of successive emissions to temperature. 3 figs.
Method and apparatus for optical temperature measurements
Angel, S. Michael; Hirschfeld, Tomas B.
1988-01-01
A method and apparatus are provided for remotely monitoring temperature. Both method and apparatus employ a temperature probe material having an excitation-dependent emission line whose fluorescence intensity varies directly with temperature whenever excited by light having a first wavelength and whose fluorescence intensity varies inversely with temperature whenever excited by light having a second wavelength. Temperature is measured by alternatively illuminating the temperature probe material with light having the first wavelength and light having the second wavelength, monitoring the intensity of the successive emissions of the excitation-dependent emission line, and relating the intensity ratio of successive emissions to temperature.
Tran, Nam K; Godwin, Zachary R; Steele, Amanda N; Wolf, Steven E; Palmieri, Tina L
2016-09-01
The goal of this study was to retrospectively evaluate the clinical impact of an accurate autocorrecting blood glucose monitoring system in children with severe burns. Blood glucose monitoring system accuracy is essential for providing appropriate intensive insulin therapy and achieving tight glycemic control in critically ill patients. Unfortunately, few comparison studies have been performed to evaluate the clinical impact of accurate blood glucose monitoring system monitoring in the high-risk pediatric burn population. Retrospective analysis of an electronic health record system. Pediatric burn ICU at an academic medical center. Children (aged < 18 yr) with severe burns (≥ 20% total body surface area) receiving intensive insulin therapy guided by either a noncorrecting (blood glucose monitoring system-1) or an autocorrecting blood glucose monitoring system (blood glucose monitoring system-2). Patient demographics, insulin rates, and blood glucose monitoring system measurements were collected. The frequency of hypoglycemia and glycemic variability was compared between the two blood glucose monitoring system groups. A total of 122 patient charts from 2001 to 2014 were reviewed. Sixty-three patients received intensive insulin therapy using blood glucose monitoring system-1 and 59 via blood glucose monitoring system-2. Patient demographics were similar between the two groups. Mean insulin infusion rates (5.1 ± 3.8 U/hr; n = 535 paired measurements vs 2.4 ± 1.3 U/hr; n = 511 paired measurements; p < 0.001), glycemic variability, and frequency of hypoglycemic events (90 vs 12; p < 0.001) were significantly higher in blood glucose monitoring system-1-treated patients. Compared with laboratory measurements, blood glucose monitoring system-2 yielded the most accurate results (mean ± SD bias: -1.7 ± 6.9 mg/dL [-0.09 ± 0.4 mmol/L] vs 7.4 ± 13.5 mg/dL [0.4 ± 0.7 mmol/L]). Blood glucose monitoring system-2 patients achieve glycemic control more quickly (5.7 ± 4.3 vs 13.1 ± 6.9 hr; p< 0.001) and stayed within the target glycemic control range longer compared with blood glucose monitoring system-1 patients (85.2% ± 13.9% vs 57.9% ± 29.1%; p < 0.001). Accurate autocorrecting blood glucose monitoring system optimizes intensive insulin therapy, improves tight glycemic control, and reduces the risk of hypoglycemia and glycemic variability. The use of an autocorrecting blood glucose monitoring system for intensive insulin therapy may improve glycemic control in severely burned children.
Continuous EEG monitoring in the intensive care unit.
Scheuer, Mark L
2002-01-01
Continuous EEG (CEEG) monitoring allows uninterrupted assessment of cerebral cortical activity with good spatial resolution and excellent temporal resolution. Thus, this procedure provides a means of constantly assessing brain function in critically ill obtunded and comatose patients. Recent advances in digital EEG acquisition, storage, quantitative analysis, and transmission have made CEEG monitoring in the intensive care unit (ICU) technically feasible and useful. This article summarizes the indications and methodology of CEEG monitoring in the ICU, and discusses the role of some quantitative EEG analysis techniques in near real-time remote observation of CEEG recordings. Clinical examples of CEEG use, including monitoring of status epilepticus, assessment of ongoing therapy for treatment of seizures in critically ill patients, and monitoring for cerebral ischemia, are presented. Areas requiring further development of CEEG monitoring techniques and indications are discussed.
Bochicchio, M; Latronico, N; Zappa, S; Beindorf, A; Candiani, A
1996-10-01
To assess the results of a 5-year experience with bedside burr hole for intracranial pressure (ICP) monitoring performed by intensive care physicians. Prospective, observational study in 120 patients. A general-neurologic Intensive Care Unit in a University Hospital. Patients admitted for acute neural lesion requiring ICP monitoring. A 2.71 mm burr hole was made with positioning of a subarachnoid screw, through which a miniaturized fiberoptic, tip transducer device (Camino) was advanced and inserted 2 mm in the frontal cortex. Over a 5-year period 120 patients, mainly with severe head trauma, underwent ICP monitoring. None of the planned patients was excluded because of technical difficulties. No life-threatening complications were reported, and the overall morbidity rate related to the ICP monitor was 3.3%. Complications were infectious in nature, with 2.5% wound infections and 0.8% meningitis. Although seven patients bled when opening the dura, no intracranial hematomas were recorded due to the ICP monitor. The fiberoptic device was left in place for 5 +/- 1.6 (SD) days (range 1-12 days). Five patients (4.1%) required catheter substitution due to breakage of the system components (fiberoptics). Bedside insertion of a ICP monitor performed by intensive care physicians is a safe procedure, with a complication rate comparable to other series published by neurosurgeons. The overall morbidity rate is comparable to, or even lower than, that caused by central vein catheterization.
Impacts of Underwater Noise on Marine Vertebrates: Project Introduction and First Results.
Liebschner, Alexander; Seibel, Henrike; Teilmann, Jonas; Wittekind, Dietrich; Parmentier, Eric; Dähne, Michael; Dietz, Rune; Driver, Jörg; van Elk, Cornelis; Everaarts, Eligius; Findeisen, Henning; Kristensen, Jacob; Lehnert, Kristina; Lucke, Klaus; Merck, Thomas; Müller, Sabine; Pawliczka, Iwona; Ronnenberg, Katrin; Rosenberger, Tanja; Ruser, Andreas; Tougaard, Jakob; Schuster, Max; Sundermeyer, Janne; Sveegaard, Signe; Siebert, Ursula
2016-01-01
The project conducts application-oriented research on impacts of underwater noise on marine vertebrates in the North and Baltic Seas. In distinct subprojects, the hearing sensitivity of harbor porpoises and gray seals as well as the acoustic tolerance limit of harbor porpoises to impulsive noise from pile driving and stress reactions caused by anthropogenic noise is investigated. Animals are equipped with DTAGs capable of recording the actual surrounding noise field of free-swimming harbor porpoises and seals. Acoustic noise mapping including porpoise detectors in the Natura 2000 sites of the North and Baltic Seas will help to fully understand current noise impacts.
Comptational Design Of Functional CA-S-H and Oxide Doped Alloy Systems
NASA Astrophysics Data System (ADS)
Yang, Shizhong; Chilla, Lokeshwar; Yang, Yan; Li, Kuo; Wicker, Scott; Zhao, Guang-Lin; Khosravi, Ebrahim; Bai, Shuju; Zhang, Boliang; Guo, Shengmin
Computer aided functional materials design accelerates the discovery of novel materials. This presentation will cover our recent research advance on the Ca-S-H system properties prediction and oxide doped high entropy alloy property simulation and experiment validation. Several recent developed computational materials design methods were utilized to the two systems physical and chemical properties prediction. A comparison of simulation results to the corresponding experiment data will be introduced. This research is partially supported by NSF CIMM project (OIA-15410795 and the Louisiana BoR), NSF HBCU Supplement climate change and ecosystem sustainability subproject 3, and LONI high performance computing time allocation loni mat bio7.
Lu, Emily; Elizondo-Riojas, Miguel-Angel; Chang, Jeffrey T; Volk, David E
2014-06-10
Next-generation sequencing results from bead-based aptamer libraries have demonstrated that traditional DNA/RNA alignment software is insufficient. This is particularly true for X-aptamers containing specialty bases (W, X, Y, Z, ...) that are identified by special encoding. Thus, we sought an automated program that uses the inherent design scheme of bead-based X-aptamers to create a hypothetical reference library and Markov modeling techniques to provide improved alignments. Aptaligner provides this feature as well as length error and noise level cutoff features, is parallelized to run on multiple central processing units (cores), and sorts sequences from a single chip into projects and subprojects.
Weigel, Angelika; Gumz, Antje; Kästner, Denise; Romer, Georg; Wegscheider, Karl; Löwe, Bernd
2015-07-01
The "Health care network anorexia and bulimia nervosa", a subproject of psychenet - the Hamburg network for mental health - aims to decrease the incidence of eating disorders as well as the risk for chronic illness courses. One focal project, therefore, evaluates a school-based prevention manual in a randomized controlled trial. The other one examines the impact of a systemic public health intervention on early treatment initiation in anorexia nervosa. The present article provides an overview about study design and interventions in both focal projects as well as preliminary results. © Georg Thieme Verlag KG Stuttgart · New York.
Dilworth, R.H.; Borkowski, C.J.
1961-12-26
A transistorized, fountain pen type radiation monitor to be worn on the person is described. Radiation produces both light flashes in a small bulb and an audible warning tone, the frequency of both the tone and light flashes being proportional to radiation intensity. The device is powered by a battery and a blocking oscillator step-up power supply The oscillator frequency- is regulated to be proportional to the radiation intensity, to provide adequate power in high radiation fields, yet minimize battery drain at low operating intensities. (AEC)
Monitoring Engine Vibrations And Spectrum Of Exhaust
NASA Technical Reports Server (NTRS)
Martinez, Carol L.; Randall, Michael R.; Reinert, John W.
1991-01-01
Real-time computation of intensities of peaks in visible-light emission spectrum of exhaust combined with real-time spectrum analysis of vibrations into developmental monitoring technique providing up-to-the-second information on conditions of critical bearings in engine. Conceived to monitor conditions of bearings in turbopump suppling oxygen to Space Shuttle main engine, based on observations that both vibrations in bearings and intensities of visible light emitted at specific wavelengths by exhaust plume of engine indicate wear and incipient failure of bearings. Applicable to monitoring "health" of other machinery via spectra of vibrations and electromagnetic emissions from exhausts. Concept related to one described in "Monitoring Bearing Vibrations For Signs Of Damage", (MFS-29734).
Miyauchi, Masaaki; Toyoda, Masao; Kaneyama, Noriko; Miyatake, Han; Tanaka, Eitaro; Kimura, Moritsugu; Umezono, Tomoya; Fukagawa, Masafumi
2016-01-01
We compared the efficacy of activity monitor (which displays exercise intensity and number of steps) versus that of pedometer in exercise therapy for patients with type 2 diabetes. The study subjects were divided into the activity monitor group ( n = 92) and pedometer group ( n = 95). The primary goal was improvement in hemoglobin A1c (HbA1c). The exercise target was set at 8,000 steps/day and 20 minutes of moderate-intensity exercise (≥3.5 metabolic equivalents). The activity monitor is equipped with a triple-axis accelerometer sensor capable of measuring medium-intensity walking duration, number of steps, walking distance, calorie consumption, and total calorie consumption. The pedometer counts the number of steps. Blood samples for laboratory tests were obtained during the visits. The first examination was conducted at the start of the study and repeated at 2 and 6 months. A significant difference in the decrease in HbA1c level was observed between the two groups at 2 months. The results suggest that the use of activity level monitor that displays information on exercise intensity, in addition to the number of steps, is useful in exercise therapy as it enhances the concept of exercise therapy and promotes lowering of HbA1c in diabetic patients.
Gerzabek, M H; Barceló, D; Bellin, A; Rijnaarts, H H M; Slob, A; Darmendrail, D; Fowler, H J; Négrel, Ph; Frank, E; Grathwohl, P; Kuntz, D; Barth, J A C
2007-07-01
The integrated project "AquaTerra" with the full title "integrated modeling of the river-sediment-soil-groundwater system; advanced tools for the management of catchment areas and river basins in the context of global change" is among the first environmental projects within the sixth Framework Program of the European Union. Commencing in June 2004, it brought together a multidisciplinary team of 45 partner organizations from 12 EU countries, Romania, Switzerland, Serbia and Montenegro. AquaTerra is an ambitious project with the primary objective of laying the foundations for a better understanding of the behavior of environmental pollutants and their fluxes in the soil-sediment-water system with respect to climate and land use changes. The project performs research as well as modeling on river-sediment-soil-groundwater systems through quantification of deposition, sorption and turnover rates and the development of numerical models to reveal fluxes and trends in soil and sediment functioning. Scales ranging from the laboratory to river basins are addressed with the potential to provide improved river basin management, enhanced soil and groundwater monitoring as well as the early identification and forecasting of impacts on water quantity and quality. Study areas are the catchments of the Ebro, Meuse, Elbe and Danube Rivers and the Brévilles Spring. Here we outline the general structure of the project and the activities conducted within eleven existing sub-projects of AquaTerra.
NASA Astrophysics Data System (ADS)
Schneider, C.; Buttstädt, M.; Merbitz, H.; Sachsen, T.; Ketzler, G.; Michael, S.; Klemme, M.; Dott, W.; Selle, K.; Hofmeister, H.
2010-09-01
This research initiative CITY 2020+ assesses the risks and opportunities for residents in urban built environments under projected demographic and climate change for the year 2020 and beyond, using the City of Aachen as a case study. CITY 2020+ develops scenarios, options and tools for planning and developing sustainable future city structures. We investigate how urban environment, political structure and residential behavior can best be adapted, with attention to the interactions among structural, political, and sociological configurations and with their consequences on human health. Demographers project that in the EU-25-States by 2050, approximately 30% of the population will be over age 65. Also by 2050, average tem¬peratures are projected to rise by 1 to 2 K. Combined, Europe can expect enhanced thermal stress and higher levels of particulate matter. CITY 2020+ amongst other sub-projects includes research project dealing with (1) a micro-scale assessment of blockages to low-level cold-air drainage flow into the city centre by vegetation and building structures, (2) a detailed analysis of the change of probability density functions related to the occurrence of heat waves during summer and the spatial and temporal structure of the urban heat island (UHI) (3) a meso-scale analysis of particulate matter (PM) concentrations depending on topography, local meteorological conditions and synoptic-scale weather patterns. First results will be presented specifically from sub-projects related to vegetation barriers within cold air drainage, the assessment of the UHI and the temporal and spatial pattern of PM loadings in the city centre. The analysis of the cold air drainage flow is investigated in two consecutive years with a clearing of vegetation stands in the beginning of the second year early in 2010. The spatial pattern of the UHI and its possible enhancement by climate change is addressed employing a unique setup using GPS devices and temperature probes fixed to several public transport units running all across the city. This is accompanied by an analysis of probability density functions (PDF) for heat waves based on recent climate data and climate projections. A dense net of 40 PM measurement sites is operated in order to obtain the spatial pattern of PM concentration as depending on meteorological condition and location. It is lined out how this climate related sub-projects interact with investigations on social networks, governance issues, buildings structure development and health outcome. Related to the later the chemical composition of PM is analyzed in more detail and related to the spatial patterns of health deficiencies. At a later stage City2020+ will propose new strategies based on cooperation from the fields of medicine, geography, sociology, history, civil engineering, and architecture for adapting the city for future needs. The Project CITY 2020+ is part of the interdisciplinary Project House HumTec (Human Sciences and Technology) at RWTH Aachen University funded by the Excellence Initiative of the German federal and state governments through the Deutsche Forschungsgemeinschaft (German Research Foundation, DFG).
A circumpolar monitoring framework for polar bears
Vongraven, Dag; Aars, Jon; Amstrup, Steven C.; Atkinson, Stephen N.; Belikov, Stanislav; Born, Erik W.; DeBruyn, T.D.; Derocher, Andrew E.; Durner, George M.; Gill, Michael J.; Lunn, Nicholas J.; Obbard, Martyn E.; Omelak, Jack; Ovsyanikov, Nikita; Peacock, Elizabeth; Richardson, E.E.; Sahanatien, Vicki; Stirling, Ian; Wiig, Øystein
2012-01-01
Polar bears (Ursus maritimus) occupy remote regions that are characterized by harsh weather and limited access. Polar bear populations can only persist where temporal and spatial availability of sea ice provides adequate access to their marine mammal prey. Observed declines in sea ice availability will continue as long as greenhouse gas concentrations rise. At the same time, human intrusion and pollution levels in the Arctic are expected to increase. A circumpolar understanding of the cumulative impacts of current and future stressors is lacking, long-term trends are known from only a few subpopulations, and there is no globally coordinated effort to monitor effects of stressors. Here, we describe a framework for an integrated circumpolar monitoring plan to detect ongoing patterns, predict future trends, and identify the most vulnerable polar bear subpopulations. We recommend strategies for monitoring subpopulation abundance and trends, reproduction, survival, ecosystem change, human-caused mortality, human–bear conflict, prey availability, health, stature, distribution, behavioral change, and the effects that monitoring itself may have on polar bears. We assign monitoring intensity for each subpopulation through adaptive assessment of the quality of existing baseline data and research accessibility. A global perspective is achieved by recommending high intensity monitoring for at least one subpopulation in each of four major polar bear ecoregions. Collection of data on harvest, where it occurs, and remote sensing of habitat, should occur with the same intensity for all subpopulations. We outline how local traditional knowledge may most effectively be combined with the best scientific methods to provide comparable and complementary lines of evidence. We also outline how previously collected intensive monitoring data may be sub-sampled to guide future sampling frequencies and develop indirect estimates or indices of subpopulation status. Adoption of this framework will inform management and policy responses to changing worldwide polar bear status and trends.
SHynergie: Development of a virtual project laboratory for monitoring hydraulic stimulations
NASA Astrophysics Data System (ADS)
Renner, Jörg; Friederich, Wolfgang; Meschke, Günther; Müller, Thomas; Steeb, Holger
2016-04-01
Hydraulic stimulations are the primary means of developing subsurface reservoirs regarding the extent of fluid transport in them. The associated creation or conditioning of a system of hydraulic conduits involves a range of hydraulic and mechanical processes but also chemical reactions, such as dissolution and precipitation, may affect the stimulation result on time scales as short as hours. In the light of the extent and complexity of these processes, the steering potential for the operator of a stimulation critically depends on the ability to integrate the maximum amount of site-specific information with profound process understanding and a large spectrum of experience. We report on the development of a virtual project laboratory for monitoring hydraulic stimulations within the project SHynergie (http://www.ruhr-uni-bochum.de/shynergie/). The concept of the laboratory envisioned product that constitutes a preparing and accompanying rather than post-processing instrument ultimately accessible to persons responsible for a project over a web-repository. The virtual laboratory consists of a data base, a toolbox, and a model-building environment. Entries in the data base are of two categories. On the one hand, selected mineral and rock properties are provided from the literature. On the other hand, project-specific entries of any format can be made that are assigned attributes regarding their use in a stimulation problem at hand. The toolbox is interactive and allows the user to perform calculations of effective properties and simulations of different types (e.g., wave propagation in a reservoir, hydraulic test). The model component is also hybrid. The laboratory provides a library of models reflecting a range of scenarios but also allows the user to develop a site-specific model constituting the basis for simulations. The laboratory offers the option to use its components following the typical workflow of a stimulation project. The toolbox incorporates simulation instruments developed in the course of the SHynergie project that account for the experimental and modeling results of the various sub-projects.
Range Atmospheric and Oceanic Environmental Support Capabilities
2011-12-01
Precipitation location/intensity, thunderstorm location/intensity, rainfall/flash flood warning, hydrometer characterization, wind warnings, and...intensity, lightning monitoring, rainfall and flash flood warning, hydrometer characterization, and wind warnings. b. Satellite: MTSAT, GOES-10
Sooyoung Kim; Robert J. McGaughey; Hans-Erik Andersen; Gerard Schreuder
2009-01-01
Tree species identification is important for a variety of natural resource management and monitoring activities including riparian buffer characterization, wildfire risk assessment, biodiversity monitoring, and wildlife habitat assessment. Intensity data recorded for each laser point in a LIDAR system is related to the spectral reflectance of the target material and...
Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit.
Singh, Jasbir K S B; Kamlin, C Omar F; Morley, Colin J; O'Donnell, Colm P F; Donath, Susan M; Davis, Peter G
2008-05-01
To determine the accuracy of pulse oximetry measurement of heart rate in the neonatal intensive care unit. Stable preterm infants were monitored with a pulse oximeter and an ECG. The displays of both monitors were captured on video. Heart rate data from both monitors, including measures of signal quality, were extracted and analysed using Bland Altman plots. In 30 infants the mean (SD) difference between heart rate measured by pulse oximetry and electrocardiography was -0.4 (12) beats per minute. Accuracy was maintained when the signal quality or perfusion was low. Pulse oximetry may provide a useful measurement of heart rate in the neonatal intensive care unit. Studies of this technique in the delivery room are indicated.
Environmental performance, profitability, asset utilization, debt monitoring and firm value
NASA Astrophysics Data System (ADS)
Bukit, R. Br; Haryanto, B.; Ginting, P.
2018-02-01
The growing issue on firm value shows that firm value is not only determined by the firm ability to increase financial profit, but also by the company's concern in maintaining the environmental condition. The industrial development produces waste that pollutes the environment that has potential to serious impact on the next life. In addition to provide financial benefits, companies are increasingly facing pressure to be socially responsible for the survival of the company. However, past findings demonstrate that the effect of environmental performance, profitability, and asset utilization to the firm’s value are still unclear. This study aims to test whether environmental performance, firm profitability and asset utilization can effectively enhance firm value in two different conditions: intensive debt monitoring and less intensive debt monitoring. Sample of companies is taken from the list of Indonesia Stock Exchange during the period of 2013 to 2015. Using multiple regression analysis, discloses that: in intensive monitoring, managers tend to have high firm value when company has high environmental performance and or high profitability and high asset utilization. Monitoring system needs to be intensified especially for companies with the above characteristics.
Emily A. Carter; Timothy P. McDonald; John L. Torbert
1999-01-01
A study was initiated in the Winter of 1998 to examine the utility of employing Global Positioning Systems (GPS) to monitor harvest traffic throughout a loblolly pine plantation and utilize traffic intensity information to assess impacts of select soil physical properties. Traffic maps prepared from GPS positional data indicated the highest concentration of traffic...
NASA Astrophysics Data System (ADS)
Desai, Shraddha S.; Devan, Shylaja; Das, Amrita; Patkar, S. M.; Rao, Mala N.
2018-04-01
Neutron scattering instruments at Dhruva reactor are equipped with in house developed neutron beam flux monitors. Measurements of variations in intensity are essential to normalize the scattered neutron spectra against the reactor power fluctuations, energy of monochromatic beam, and various other factors. Two different beam monitor geometries are considered as per the beam size and optics. These detectors are fabricated with tailor-made designs to suit individual beam size and neutron flux. Pencil size beam monitors for integral intensity measurement are fabricated with coaxial geometry and BF3 fill gas for high n-gamma discrimination and count rate capability. Brass cathode design is modified to SS based rugged design, considering beam transmission. Coaxial beam monitor partially intercepts the collimated beam and gives relative magnitude of the flux with time. For certain experiments, size of beam varies due to use of focusing monochromator. Thus a beam monitor with square sensitive region covering entire beam is essential. Multiwire based planar detector for use in transmission mode is designed. Negligible absorption of neutron beam intensity within the detector hardware is ensured. Design of detectors is tailor made for beam geometry. Both these types of beam monitors are fabricated and characterized at G2 beam line and Triple Axis Spectrometer at Dhruva reactor. Performance of detector is suitable for the beam monitoring up to neutron flux ˜ 106 n/cm2/sec. Design aspects and performance details of these beam monitors are mentioned in the paper.
Intensive care window: real-time monitoring and analysis in the intensive care environment.
Stylianides, Nikolas; Dikaiakos, Marios D; Gjermundrød, Harald; Panayi, George; Kyprianou, Theodoros
2011-01-01
This paper introduces a novel, open-source middleware framework for communication with medical devices and an application using the middleware named intensive care window (ICW). The middleware enables communication with intensive care unit bedside-installed medical devices over standard and proprietary communication protocol stacks. The ICW application facilitates the acquisition of vital signs and physiological parameters exported from patient-attached medical devices and sensors. Moreover, ICW provides runtime and post-analysis procedures for data annotation, data visualization, data query, and analysis. The ICW application can be deployed as a stand-alone solution or in conjunction with existing clinical information systems providing a holistic solution to inpatient medical condition monitoring, early diagnosis, and prognosis.
VizieR Online Data Catalog: X-ray/UV Swift monitoring of NGC 4151 (Edelson+, 2017)
NASA Astrophysics Data System (ADS)
Edelson, R.; Gelbord, J.; Cackett, E.; Connolly, S.; Done, C.; Fausnaugh, M.; Gardner, E.; Gehrels, N.; Goad, M.; Horne, K.; McHardy, I.; Peterson, B. M.; Vaughan, S.; Vestergaard, M.; Breeveld, A.; Barth, A. J.; Bentz, M.; Bottorff, M.; Brandt, W. N.; Crawford, S. M.; Bonta, E. D.; Emmanoulopoulos, D.; Evans, P.; Jaimes, R. F.; Filippenko, A. V.; Ferland, G.; Grupe, D.; Joner, M.; Kennea, J.; Korista, K. T.; Krimm, H. A.; Kriss, G.; Leonard, D. C.; Mathur, S.; Netzer, H.; Nousek, J.; Page, K.; Romero-Colmenero, E.; Siegel, M.; Starkey, D. A.; Treu, T.; Vogler, H. A.; Winkler, H.; Zheng, W.
2017-11-01
During 2016 February 20 through April 29, Swift executed an intensive monitoring campaign on NGC 4151, consisting of 319 separate visits of at least 120s, an average of nearly five visits per day. These Swift observations were coordinated with intensive monitoring with numerous ground-based telescopes including the Las Cumbres Observatory Global Telescope network and the Liverpool Telescope at La Palma. Those data will be presented in subsequent papers (K. Horne et al. 2017, in preparation; M. Goad et al. 2017, in preparation). (3 data files).
Validity of Wearable Activity Monitors during Cycling and Resistance Exercise.
Boudreaux, Benjamin D; Hebert, Edward P; Hollander, Daniel B; Williams, Brian M; Cormier, Corinne L; Naquin, Mildred R; Gillan, Wynn W; Gusew, Emily E; Kraemer, Robert R
2018-03-01
The use of wearable activity monitors has seen rapid growth; however, the mode and intensity of exercise could affect the validity of heart rate (HR) and caloric (energy) expenditure (EE) readings. There is a lack of data regarding the validity of wearable activity monitors during graded cycling regimen and a standard resistance exercise. The present study determined the validity of eight monitors for HR compared with an ECG and seven monitors for EE compared with a metabolic analyzer during graded cycling and resistance exercise. Fifty subjects (28 women, 22 men) completed separate trials of graded cycling and three sets of four resistance exercises at a 10-repetition-maximum load. Monitors included the following: Apple Watch Series 2, Fitbit Blaze, Fitbit Charge 2, Polar H7, Polar A360, Garmin Vivosmart HR, TomTom Touch, and Bose SoundSport Pulse (BSP) headphones. HR was recorded after each cycling intensity and after each resistance exercise set. EE was recorded after both protocols. Validity was established as having a mean absolute percent error (MAPE) value of ≤10%. The Polar H7 and BSP were valid during both exercise modes (cycling: MAPE = 6.87%, R = 0.79; resistance exercise: MAPE = 6.31%, R = 0.83). During cycling, the Apple Watch Series 2 revealed the greatest HR validity (MAPE = 4.14%, R = 0.80). The BSP revealed the greatest HR accuracy during resistance exercise (MAPE = 6.24%, R = 0.86). Across all devices, as exercise intensity increased, there was greater underestimation of HR. No device was valid for EE during cycling or resistance exercise. HR from wearable devices differed at different exercise intensities; EE estimates from wearable devices were inaccurate. Wearable devices are not medical devices, and users should be cautious when using these devices for monitoring physiological responses to exercise.
NASA AETC Test Technology Subproject
NASA Technical Reports Server (NTRS)
Bell, James
2017-01-01
Funds directed to improve measurement capabilities (pressure, force, flow, and temperature), test techniques and processes, and develop technologies critical to meeting NASA research needs and applicable to a multitude of facilities. Primarily works by funding small ($40K - $400K) tasks which result in a demonstration or initial capability of a new technology in an AETC facility.TT research and development tasks are generally TRL 3-6; they should be things which work in small scale or lab environments but need further development for use in production facilities.TT differs from CA in its focus on smaller-scale tasks and on instrumentation. Technologies developed by TT may become CA projects in order be fully realized within a facility.
NASA Technical Reports Server (NTRS)
Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.
2016-01-01
This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.
2010-10-21
the volume of cell bodies smaller than in control subjects by: 22 % in the caudate nucleus (p < 0.025*), 21% in the putamen (p < 0.042*), 31% in the...of cell 68814_C001.indd 9 6/ 22 /2009 12:32:42 PM 10 Autism: Oxidative Stress, Infl ammation and Immune Abnormalities proliferation, apoptosis...containing cells in the brain of 7- to 14-year-old autistic subjects (by 69% in area 22 , 149% in area 39, and 45% in area 44). The increase in the
ERIC Educational Resources Information Center
Schopp, Laura H.; Clark, Mary J.; Lamberson, William R.; Uhr, David J.; Minor, Marian A.
2017-01-01
The purpose of this study was to determine and compare outcomes of two voluntary workplace health management methods: an adapted worksite self-management (WSM) approach and an intensive health monitoring (IM) approach. Research participants were randomly assigned to either the WSM group or the IM group by a computer-generated list (n = 180; 92 WSM…
Hellmund, Richard; Weitgasser, Raimund; Blissett, Deirdre
2018-04-01
To estimate the costs associated with a flash glucose monitoring system as a replacement for routine self-monitoring of blood glucose (SMBG) in patients with type 1 diabetes mellitus (T1DM) using intensive insulin, from a UK National Health Service (NHS) perspective. The base-case cost calculation was created using the maximum frequency of glucose monitoring recommended by the 2015 National Institute for Health and Care Excellence guidelines (4-10 tests per day). Scenario analyses considered SMBG at the frequency observed in the IMPACT clinical trial (5.6 tests per day) and at the frequency of flash monitoring observed in a real-world analysis (16 tests per day). A further scenario included potential costs associated with severe hypoglycaemia. In the base case, the annual cost per patient using flash monitoring was £234 (19%) lower compared with routine SMBG (10 tests per day). In scenario analyses, the annual cost per patient of flash monitoring compared with 5.6 and 16 SMBG tests per day was £296 higher and £957 lower, respectively. The annual cost of severe hypoglycaemia for flash monitoring users was estimated to be £221 per patient, compared with £428 for routine SMBG users (based on 5.6 tests/day), corresponding to a reduction in costs of £207. The flash monitoring system has a modest impact on glucose monitoring costs for the UK NHS for patients with T1DM using intensive insulin. For people requiring frequent tests, flash monitoring may be cost saving, especially when taking into account potential reductions in the rate of severe hypoglycaemia. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Efficient color correction method for smartphone camera-based health monitoring application.
Duc Dang; Chae Ho Cho; Daeik Kim; Oh Seok Kwon; Jo Woon Chong
2017-07-01
Smartphone health monitoring applications are recently highlighted due to the rapid development of hardware and software performance of smartphones. However, color characteristics of images captured by different smartphone models are dissimilar each other and this difference may give non-identical health monitoring results when the smartphone health monitoring applications monitor physiological information using their embedded smartphone cameras. In this paper, we investigate the differences in color properties of the captured images from different smartphone models and apply a color correction method to adjust dissimilar color values obtained from different smartphone cameras. Experimental results show that the color corrected images using the correction method provide much smaller color intensity errors compared to the images without correction. These results can be applied to enhance the consistency of smartphone camera-based health monitoring applications by reducing color intensity errors among the images obtained from different smartphones.
Introducing a modular activity monitoring system.
Reiss, Attila; Stricker, Didier
2011-01-01
In this paper, the idea of a modular activity monitoring system is introduced. By using different combinations of the system's three modules, different functionality becomes available: 1) a coarse intensity estimation of physical activities 2) different features based on HR-data and 3) the recognition of basic activities and postures. 3D-accelerometers--placed on lower arm, chest and foot--and a heart rate monitor were used as sensors. A dataset with 8 subjects and 14 different activities was recorded to evaluate the performance of the system. The overall performance on the intensity estimation task, relying on the chest-worn accelerometer and the HR-monitor, was 94.37%. The overall performance on the activity recognition task, using all three accelerometer placements and the HR-monitor, was 90.65%. This paper also gives an analysis of the importance of different accelerometer placements and the importance of a HR-monitor for both tasks.
Ciani, Oriana; Piccini, Luca; Parini, Sergio; Rullo, Alessia; Bagnoli, Franco; Marti, Patrizia; Andreoni, Giuseppe
2008-01-01
Pervasive computing research is introducing new perspectives in a wide range of applications, including healthcare domain. In this study we explore the possibility to realize a prototype of a system for unobtrusive recording and monitoring of multiple biological parameters on premature newborns hospitalized in the Neonatal Intensive Care Unit (NICU). It consists of three different units: a sensitized belt for Electrocardiogram (ECG) and chest dilatation monitoring, augmented with extrinsic transducers for temperature and respiratory activity measure, a device for signals pre-processing, sampling and transmission through Bluetooth(R) (BT) technology to a remote PC station and a software for data capture and post-processing. Preliminary results obtained by monitoring babies just discharged from the ward demonstrated the feasibility of the unobtrusive monitoring on this kind of subjects and open a new scenario for premature newborns monitoring and developmental cares practice in NICU.
Cheng, D C; Newman, M F; Duke, P; Wong, D T; Finegan, B; Howie, M; Fitch, J; Bowdle, T A; Hogue, C; Hillel, Z; Pierce, E; Bukenya, D
2001-05-01
We compared (a) the perioperative complications; (b) times to eligibility for, and actual time of the following: extubation, less intense monitoring, intensive care unit (ICU), and hospital discharge; and (c) resource utilization of nursing ratio for patients receiving either a typical fentanyl/isoflurane/propofol regimen or a remifentanil/isoflurane/propofol regimen for fast-track cardiac anesthesia in 304 adults by using a prospective randomized, double-blinded, double-dummy trial. There were no differences in demographic data, or perioperative mortality and morbidity between the two study groups. The mini-mental status examination at postoperative Days 1 to 3 were similar between the two groups. The eligible and actual times for extubation, less intense monitoring, ICU discharge, and hospital discharge were not significantly different. Further analyses revealed no differences in times for extubation and resource utilization after stratification by preoperative risk scores, age, and country. The nurse/patient ratio was similar between the remifentanil/isoflurane/propofol and fentanyl/isoflu-rane/propofol groups during the initial ICU phase and less intense monitoring phase. Increasing preoperative risk scores and older age (>70 yr) were associated with longer times until extubation (eligible), ICU discharge (eligible and actual), and hospital discharge (eligible and actual). Times until extubation (eligible and actual) and less intense monitoring (eligible) were significantly shorter in Canadian patients than United States' patients. However, there was no difference in hospital length of stay in Canadian and United States' patients. We conclude that both anesthesia techniques permit early and similar times until tracheal extubation, less intense monitoring, ICU and hospital discharge, and reduced resource utilization after coronary artery bypass graft surgery. An ultra-short opioid technique was compared with a standard fast-track small-dose opioid technique in coronary artery bypass graft patients in a prospective randomized, double-blinded controlled study. The postoperative recovery and resource utilization, including stratification of preoperative risk score, age, and country, were analyzed.
Low-intensity, stocker-based channel catfish culture
USDA-ARS?s Scientific Manuscript database
Low-intensity Channel Catfish production is characterized by low stocking rates, low installed aeration capacity, and no automated dissolved oxygen monitoring. Two studies conducted in nine 0.25-acre ponds quantified production characteristics of stocker Channel Catfish stocked for low-intensity foo...
High Intensity Tests of the NuMI Beam Monitoring Ionization Chambers
NASA Astrophysics Data System (ADS)
Zwaska, Robert
2002-04-01
The NuMI facility at Fermilab will generate an intense beam of neutrinos directed toward Soudan, MN, 735 km away. Components of the planned beam monitoring system will be exposed to fluences of up to 8 x 10^9 charge particles / cm^2 and 6 x 10^10 neutrons / cm^2 in an 8.6 us beam spill. These fluences will be measured by an array of Helium ionization chambers. We tested a pair of chambers with 8 GeV protons at the Fermilab Booster accelerator, and with high intensity neutron sources at the Texas Experimental Nuclear Facility.
NASA Astrophysics Data System (ADS)
De Siena, Luca; Rawlinson, Nicholas
2016-04-01
Non-standard seismic imaging (velocity, attenuation, and scattering tomography) of the North Sea basins by using unexploited seismic intensities from previous passive and active surveys are key for better imaging and monitoring fluid under the subsurface. These intensities provide unique solutions to the problem of locating/tracking gas/fluid movements in the crust and depicting sub-basalt and sub-intrusives in volcanic reservoirs. The proposed techniques have been tested in volcanic Islands (Deception Island) and have been proved effective at monitoring fracture opening, imaging buried fluid-filled bodies, and tracking water/gas interfaces. These novel seismic attributes are modelled in space and time and connected with the lithology of the sampled medium, specifically density and permeability with as key output a novel computational code with strong commercial potential.
Impact of court monitoring on DWI adjudication
DOT National Transportation Integrated Search
1990-12-01
Author's abstract: Court monitoring of Driving While Intoxicated (DWI) cases is a labor intensive effort conducted by over 300 concerned citizen groups across the U.S. The present project assessed the impact of court monitoring by analyzing the diffe...
Long-Term Solar and Cosmic Radiation Data Bases
1991-01-01
determine the magnitude of the variations in the cosmic ray intensity caused by solar activity. Neutron monitors, with their much lower energy threshold...expression that neutron monitors are sensors on spacecraft EARTH. Here we will consider cosmic ray detectors to measure two components of cosmic ...A comparison with the solar cycle as illustrated by the sunspot number in Fig. 1. shows that the maximum cosmic ray intensity occurs near sunspot
Johnson, Steven M.; Swanson, Robert B.
1994-01-01
Prototype stream-monitoring sites were operated during part of 1992 in the Central Nebraska Basins (CNBR) and three other study areas of the National Water-Quality Assessment (NAWQ) Program of the U.S. Geological Survey. Results from the prototype project provide information needed to operate a net- work of intensive fixed station stream-monitoring sites. This report evaluates operating procedures for two NAWQA prototype sites at Maple Creek near Nickerson and the Platte River at Louisville, eastern Nebraska. Each site was sampled intensively in the spring and late summer 1992, with less intensive sampling in midsummer. In addition, multiple samples were collected during two high- flow periods at the Maple Creek site--one early and the other late in the growing season. Water-samples analyses included determination of pesticides, nutrients, major ions, suspended sediment, and measurements of physical properties. Equipment and protocols for the water-quality sampling procedures were evaluated. Operation of the prototype stream- monitoring sites included development and comparison of onsite and laboratory sample-processing proce- dures. Onsite processing was labor intensive but allowed for immediate preservation of all sampled constituents. Laboratory processing required less field labor and decreased the risk of contamination, but allowed for no immediate preservation of the samples.
BERRETTINI, S.; ARSLAN, E.; BAGGIANI, A.; BURDO, S.; CASSANDRO, E.; CUDA, D.; FILIPO, R.; GIORGI ROSSI, P.; MANCINI, P.; MARTINI, A.; QUARANTA, A.; QUARANTA, N.; TURCHETTI, G.; FORLI, F.
2011-01-01
SUMMARY The aim of Health Technology Assessment (HTA) is to provide decision-makers, distributors and recipients with information on the effectiveness, cost and impact of health technologies. The present study constitutes a subproject within the wider project “Analysis of the impact of professional involvement in evidence generation for the HTA process”, which is part of the strategic programme “Transfer of the results of the research in clinical practice and organisation of healthcare services”, coordinated by Laziosanità – Agency of Public Healthcare of the Lazio Region and AgeNaS (National Agency for Regional Healthcare Services). The objectives of the present subproject (cochlear implants) are as follows: a) to produce a report regarding the health impact of cochlear implants (CI) on their recipients, through a systematic review of literature and extensive selection of relative studies, combining the outcomes with metanalytical techniques. Output: report on the indications of usage in the groups of population for which benefits are controversial; b) to create a registry of patients using cochlear implants. The registry should contain a selection of anagraphic and clinical information relative to patient follow-up in order to assess factors associated with safety and impact on cochlear implant users. This source of information is essential for future observational studies. This was divided into 4 phases: 1st phase: definition of key participants in the assessment process; 2nd phase: definition of methods and timing of “Aims” (definition of the objective); 3rd phase: definition of the methods and times of the “assessment process”, 4th phase: production of the final report. From the analysis of systematic reviews and italian and international guidelines, the Working Group members approved recommendations on the following topics: results after CI in children in relation to age at implantation, bilateral CI in children, CI in deaf children with associated disabilities, CI in adults with advanced age, bilateral CI in adults and CI in adults with pre-lingual deafness. These recommendations have also been evaluated by the Consulting Committee members and approved with minimal suggestions. PMID:22287819
Cooperative Projects - Challenges and Opportunities
NASA Astrophysics Data System (ADS)
Schubotz, Wiebke; Brücher, Tim; Vamborg, Freja
2017-04-01
Today's research in Germany is often organized in large projects and collaborations, so-called cooperative projects ("Verbundprojekte" in German). These projects are defined by a large number of members (more than 50) and participating institutes, e.g. institutes of research organizations such as the Max-Planck society and the Leibniz association, Helmholtz centres, and universities. For coordination purposes these projects usually have a general project manager or project coordinator close to the speaker of the project. Despite this overarching position, it is often challenging for the project manager to really overview the entire project as he is, for example, not involved in the individual institute's recruitment processes or research connections to other institutes via other projects. Additionally, there is neither a formal obligation for the principal investigators and project scientists to report changes within their sub-projects, nor any formal dependency between these sub-projects and the coordination office to ensure a contemporary update of changes and progress in their specific tasks of the project. Therefore, the idea of a coordinating position to oversee the entire cooperative project is sometimes difficult to reach. Furthermore, project managers usually have no formal connection to other project managers. This means that recurrent tasks, for which cooperation between project managers would be helpful, need to be reinvented for each project anew. Due to the lack of this more formalized cooperation between project managers, acquired expertise is often lost. We will illustrate the challenges of this kind of project management based on projects at the Max Planck Institute for Meteorology (Hamburg) and the Helmholtz Centre for Ocean Research (GEOMAR, Kiel), but also point out opportunities that arise within a large collaboration of partners. Moreover, we present an approach to coordinate management processes in order to overcome some of the aforementioned challenges across several cooperative projects - a virtual centre for earth system science management (CESSMA).
NASA Astrophysics Data System (ADS)
Yang, Xiaolin; Wu, Zhongliang; Jiang, Changsheng; Xia, Min
2011-05-01
One of the important issues in macroseismology and engineering seismology is how to get as much intensity and/or strong motion data as possible. We collected and studied several cases in the May 12, 2008, Wenchuan earthquake, exploring the possibility of estimating intensities and/or strong ground motion parameters using civilian monitoring videos which were deployed originally for security purposes. We used 53 video recordings in different places to determine the intensity distribution of the earthquake, which is shown to be consistent with the intensity distribution mapped by field investigation, and even better than that given by the Community Internet Intensity Map. In some of the videos, the seismic wave propagation is clearly visible, and can be measured with the reference of some artificial objects such as cars and/or trucks. By measuring the propagating wave, strong motion parameters can be roughly but quantitatively estimated. As a demonstration of this `propagating-wave method', we used a series of civilian videos recorded in different parts of Sichuan and Shaanxi and estimated the local PGAs. The estimate is compared with the measurement reported by strong motion instruments. The result shows that civilian monitoring video provide a practical way of collecting and estimating intensity and/or strong motion parameters, having the advantage of being dynamic, and being able to be played back for further analysis, reflecting a new trend for macroseismology in our digital era.
NASA Astrophysics Data System (ADS)
Zourabian, Anna; Boas, David A.
2001-06-01
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to electronic fetal heart rate monitoring (cardiotocography) because it allows direct assessment of both fetal oxygen status and fetal tissue perfusion. Here we present the analysis for determining the most optimal wavelength selection for pulse oximetry. The wavelengths we chose as the most optimal are: the first in the range of 670-720nm and the second in the range of 825-925nm. Further we discuss the possible systematic errors during our measurements, and their contribution to the obtained saturation results.
Conversion of woodlands changes soil related ecosystem services in Subsaharan Africa
NASA Astrophysics Data System (ADS)
Groengroeft, Alexander; Landschreiber, Lars; Luther-Mosebach, Jona; Masamba, Wellington; Zimmermann, Ibo; Eschenbach, Annette
2015-04-01
In remote areas of Subsaharan Africa, growing population, changes in consumption patterns and increasing global influences are leading to a strong pressure on the land resources. Smallholders convert woodlands by fire, grazing and clearing in different intensities thus changing soil properties and their ecosystem functioning. As the extraction of ecosystem services forms the basis of local wellbeing for many communities, the role of soils in providing ecosystem services is of high importance. Since 2010, "The Future Okavango" project investigates the quantification of ecosystem functions and services at four core research sites along the Okavango river basin (Angola, Namibia, Botswana, see http://www.future-okavango.org/). These research sites have an extent of 100 km2 each. Within our subproject the soil functions underlying ecosystem services are studied: The amount and spatial variation of soil nutrient reserves in woodland and their changes by land use activities, the water storage function as a basis for plant growth, and their effect on groundwater recharge and the carbon storage function. The scientific framework consists of four major parts including soil survey and mapping, lab analysis, field measurements and modeling approaches on different scales. A detailed soil survey leads to a measure of the spatial distribution, extent and heterogeneity of soil types for each research site. For generalization purposes, geomorphological and pedological characteristics are merged to derive landscape units. These landscape units have been overlaid by recent land use types to stratify the research site for subsequent soil sampling. On the basis of field and laboratory analysis, spatial distribution of soil properties as well as boundaries between neighboring landscape units are derived. The parameters analysed describe properties according to grain size distribution, organic carbon content, saturated and unsaturated hydraulic conductivity as well as pore space distribution. At nine selected sites, soil water contents and pressure heads are logged throughout the year with a 12 hour resolution in depth of 10 to 160 cm. This monitoring gives information about soil water dynamics at point scale and the database is used to evaluate model outputs of soil water balances later on. To derive point scale soil water balances for each landscape unit the one dimensional and physically based model SWAP 3.2 is applied. The presentation will demonstrate the conceptual framework, exemplary results and will discuss, if the ecosystem service approach can help to avoid future land degradation. Key word: Okavango catchment, soil functions, conceptual approach
Gas Filled RF Resonator Hadron Beam Monitor for Intense Neutrino Beam Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yonehara, Katsuya; Abrams, Robert; Dinkel, Holly
MW-class beam facilities are being considered all over the world to produce an intense neutrino beam for fundamental particle physics experiments. A radiation-robust beam monitor system is required to diagnose the primary and secondary beam qualities in high-radiation environments. We have proposed a novel gas-filled RF-resonator hadron beam monitor in which charged particles passing through the resonator produce ionized plasma that changes the permittivity of the gas. The sensitivity of the monitor has been evaluated in numerical simulation. A signal manipulation algorithm has been designed. A prototype system will be constructed and tested by using a proton beam at themore » MuCool Test Area at Fermilab.« less
Laser intensity modulated real time monitoring cell growth sensor for bioprocess applications
NASA Astrophysics Data System (ADS)
Kishore, P.; Babu, P. Ravindra; Devi, V. Rama; Maunika, T.; Soujanya, P.; Kishore, P. V. N.; Dinakar, D.
2016-04-01
This article proposes an optical method for monitoring the growth of Escherichia coli in Luria Bertani medium and Saccharomyces cereviciae in YPD. Suitable light is selected which on interaction with the analyte under consideration, gets adsorption / scattered. Required electronic circuitry is designed to drive the laser source and to detect the intensity of light using Photo-detector. All these components are embedded and arranged in a proper way and monitored the growth of the microbs in real time. The sensors results are compared with standard techniques such as colorimeter, Nephelometer and hemocytometer. The experimental results are in good agreement with the existed techniques and well suitable for real time monitoring applications of the growth of the microbs.
Catfish production using intensive aeration
USDA-ARS?s Scientific Manuscript database
For the last 3 years, researchers at UAPB and NWAC have been monitoring and verifying production yields in intensively aerated catfish ponds with aeration rates greater than 6 hp/acre. We now have three years of data on commercial catfish production in intensively aerated ponds. With stocking densi...
NASA Astrophysics Data System (ADS)
Kudella, Peter; Loges, Iryna; Mutschler, Thomas; Eiche, Elisabeth; Ruppert, Julia; Neumann, Thomas
2016-09-01
In the framework of the Integrated Water Resources Management (IWRM) joint research project in the karst area of Gunung Kidul, Province of Yogyakarta Special Region on the Java Island, Indonesia, an underground hydropower driven water extraction facility in the cave "Bribin" was developed using pump-as-turbine-driven systems for freshwater supply of the rural area. As numerous other caves in the Gunung Kidul area, Bribin is part of a ramified system of all-season water-bearing subterraneous rivers and natural caves in karstic limestone. The elliptic cross section of the cave was completely closed with a concrete barrage, thus creating a year-round underground retention volume with an operational storage level of approx. 15 m. This contribution highlights the geotechnical and geohydraulic challenges handled within the sub-project "Short-time and long-time behaviour of karst rock surrounding pressure-bearing underground water-retaining structures". One key to the feasibility of an artificial water retention scheme in a natural cave is to ensure the mechanical stability of the cave roof and sidewalls. The necessary geotechnical investigations are described. Another key to the effectiveness of such a water retention concept is the control and minimization of "lost" seepage water bypassing the barrage structure through the karst rock mass. Measures to monitor and to explain the seepage phenomena are presented as well as grouting efforts to minimize them. The limitations of improving the overall tightness will be discussed. Interpretation includes the use of analytical and numerical methods.
Simultaneous Time, Wavelength and Intensity Measurement of Optical Memory Subsystems
1998-07-01
SIMULTANEOUS TIME, WAVELENGTH AND INTENSITY MEASUREMENT PE - 61102F OF OPTICAL MEMORY SUBSYSTEMS PR - 2300 6. AUTHOR( S ) TA - 06 WU -03 Joseph Osman and...Rebecca Bussjager 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER AFRL/SNDP25 letnic AFRL-SN-RS-TR- 1998...12025 Electronic Pky Rome, NY 13441-4515 9. SPONSORING/MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSORING/MONITORING AGENCY REPORT NUMBER
Critical loads and their exceedances at intensive forest monitoring sites in Europe.
Lorenz, Martin; Nagel, Hans-Dieter; Granke, Oliver; Kraft, Philipp
2008-10-01
Intensive forest monitoring by means of harmonised methods has been conducted in Europe for more than a decade. Risks of atmospheric nitrogen and sulphur deposition are assessed by means of calculations of critical loads and their exceedances. In the present study throughfall and bulk deposition of nitrate (N-NO(3)), ammonium (N-NH(4)) and sulphate (S-SO(4)) show marked spatial patterns and temporal trends. In the period of observation (1999-2004), sulphate deposition on intensive monitoring plots decreased by about one quarter. This is in line with the reduction of S deposition by 70% since 1981 in Europe as a result of successful air pollution control politics under the Convention on Long-range Transboundary Air Pollution (CLRTAP). However, sulphate and especially nitrate and ammonium deposition were found to still exceed critical loads at many forest sites, indicating a continued need for further implementation of air pollution abatement strategies.
Beam diagnostics at high-intensity storage rings
NASA Astrophysics Data System (ADS)
Plum, Mike
1994-10-01
Beam diagnostics at high-intensity facilities feature their own special set of problems and characteristics, issues peculiar to high-intensity storage rings include beam loss, beam halos, extraction efficiency, beam in the gap, clearing electrodes, and beam-profile measurement. The Los Alamos Proton Storage Ring (PSR) is a nice example of a high-intensity storage ring. I will discuss in some detail three diagnostic systems currently in use at the PSR: the beam-loss-monitor system, the electron-clearing system, and the beam-in-the-gap monitor. Much of our discussion is inspired by the problems we have encountered and the useful things we have learned while commissioning and developing the PSR. Another inspiration is our work on the next-generation neutron-spallation source, also known as the National Center for Neutron Research (NCNR).
Collins, Brian D.; Stock, Jonathan; Weber, Lisa C.; Whitman, K.; Knepprath, N.
2012-01-01
Intense winter storms in the San Francisco Bay area (SFBA) of California, USA often trigger shallow landslides. Some of these landslides mobilize into potentially hazardous debris flows. A growing body of research indicates that rainfall intensity-duration thresholds are insufficient for accurate prediction of landslide occurrence. In response, we have begun long-term monitoring of the hydrologic response of land-slide-prone hillslopes to rainfall in several areas of the SFBA. Each monitoring site is equipped with sensors for measuring soil moisture content and piezometric pressure at several soil depths along with a rain gauge connected to a cell phone or satellite telemetered data logger. The data are transmitted in near-real-time, providing the ability to monitor hydrologic conditions before, during, and after storms. Results are guiding the establishment of both antecedent and storm-specific rainfall and moisture content thresholds which must be achieved before landslide-causative positive pore water pressures are generated. Although widespread shallow landsliding has not yet occurred since the deployment of the monitoring sites, several isolated land-slides have been observed in the area of monitoring. The landslides occurred during a period when positive pore water pressures were measured as a result of intense rainfall that followed higher-than-average season precipitation totals. Continued monitoring and analysis will further guide the establishment of more general-ized thresholds for different regions of the SFBA and contribute to the development and calibration of physi-cally-based predictive models.
Neural Correlates of the Lombard Effect in Primate Auditory Cortex
Eliades, Steven J.
2012-01-01
Speaking is a sensory-motor process that involves constant self-monitoring to ensure accurate vocal production. Self-monitoring of vocal feedback allows rapid adjustment to correct perceived differences between intended and produced vocalizations. One important behavior in vocal feedback control is a compensatory increase in vocal intensity in response to noise masking during vocal production, commonly referred to as the Lombard effect. This behavior requires mechanisms for continuously monitoring auditory feedback during speaking. However, the underlying neural mechanisms are poorly understood. Here we show that when marmoset monkeys vocalize in the presence of masking noise that disrupts vocal feedback, the compensatory increase in vocal intensity is accompanied by a shift in auditory cortex activity toward neural response patterns seen during vocalizations under normal feedback condition. Furthermore, we show that neural activity in auditory cortex during a vocalization phrase predicts vocal intensity compensation in subsequent phrases. These observations demonstrate that the auditory cortex participates in self-monitoring during the Lombard effect, and may play a role in the compensation of noise masking during feedback-mediated vocal control. PMID:22855821
Günther, Anders C; Bottai, Matteo; Schandl, Anna R; Storm, Hanne; Rossi, Patrik; Sackey, Peter V
2013-03-19
Many intensive care unit (ICU) patients describe pain and other adverse feelings that may impact long-term psychological morbidity. Sympathetically mediated palmar skin conductance variability is related to emotionally induced perspiration and correlates with pain levels in the perioperative setting but has not been studied in ICU patients. Twenty non-intubated and 20 intubated general ICU patients were included in this observational study. Patients were monitored with the MED-STORM Pain Monitoring System®. The number of skin conductance fluctuations per second (NSCF) was measured in parallel with bedside observation during one hour of intensive care, including rest, procedures and patient-staff interactions. Arousal-agitation level was monitored with the motor activity assessment scale (MAAS). Pain was monitored with the numeric rating scale (0 to 10) in patients able to communicate or by observation in patients unable to communicate. In non-intubated patients, NSCF increased with increasing stimulation/pain but also with higher MAAS (P=0.002). An interaction effect was found, with increased NSCF response to stimulation/pain with increasing MAAS (P<0.001). In critically ill patients, NSCF may be more useful evaluating emotional distress rather than pain alone. It needs to be assessed whether NSCF monitoring is clinically useful and whether controlling emotional distress with the aid of such monitoring may impact on patient care and outcomes.
HOST turbine heat transfer program summary
NASA Technical Reports Server (NTRS)
Gladden, Herbert J.; Simoneau, Robert J.
1988-01-01
The objectives of the HOST Turbine Heat Transfer subproject were to obtain a better understanding of the physics of the aerothermodynamic phenomena and to assess and improve the analytical methods used to predict the flow and heat transfer in high temperature gas turbines. At the time the HOST project was initiated, an across-the-board improvement in turbine design technology was needed. A building-block approach was utilized and the research ranged from the study of fundamental phenomena and modeling to experiments in simulated real engine environments. Experimental research accounted for approximately 75 percent of the funding with the remainder going to analytical efforts. A healthy government/industry/university partnership, with industry providing almost half of the research, was created to advance the turbine heat transfer design technology base.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Covey, Curt; Hoffman, Forrest
2008-10-02
This project will quantify selected components of climate forcing due to changes in the terrestrial biosphere over the period 1948-2004, as simulated by the climate / carboncycle models participating in C-LAMP (the Carbon-Land Model Intercomparison Project; see http://www.climatemodeling.org/c-lamp). Unlike other C-LAMP projects that attempt to close the carbon budget, this project will focus on the contributions of individual biomes in terms of the resulting climate forcing. Bala et al. (2007) used a similar (though more comprehensive) model-based technique to assess and compare different components of biospheric climate forcing, but their focus was on potential future deforestation rather than the historicalmore » period.« less
A First Look at the DGEN380 Engine Acoustic Data from a Core-Noise Perspective
NASA Technical Reports Server (NTRS)
Hultgren, Lennart S.
2015-01-01
This work is a first look at acoustic data acquired in the NASA Glenn Research Center Aero-Acoustic Propulsion Laboratory using the Price Induction DGEN380 small turbofan engine, with particular emphasis on broadband combustor (core) noise. Combustor noise is detected by using a two-signal source separation technique employing one engine-internal sensor and one semi-far-field microphone. Combustor noise is an important core-noise component and is likely to become a more prominent contributor to overall airport community noise due to turbofan design trends, expected aircraft configuration changes, and advances in fan-noise-mitigation techniques. This work was carried out under the NASA Fundamental Aeronautics Program, Fixed Wing Project, Quiet Performance Subproject
Real-time fluorescence microscopy monitoring of porphyrin biodistribution
NASA Astrophysics Data System (ADS)
Kimel, Sol; Gottfried, Varda; Kunzi-Rapp, Karin; Akguen, Nermin; Schneckenburger, Herbert
1996-01-01
In vivo uptake of the natural porphyrins, uroporphyrin III (UP), coproporphyrin III (CP) and protoporphyrin IX (PP), was monitored by fluorescence microscopy. Experiments were performed using the chick chorioallantoic membrane (CAM) model, which allowed video documentation of fluorescence both in real time and after integration over a chosen time interval (usually 2 s). Sensitizers at a concentration of 50 (mu) M (100 (mu) L) were injected into a medium-sized vein (diameter approximately 40 micrometer) using an ultra-fine 10 micrometer diameter needle. Fluorescence images were quantitated by subtracting the fluorescence intensity of surrounding CAM tissue (Fmatrix) from the intravascular fluorescence intensity (Fintravascular), after transformation of the video frames into digital form. The differential fluorescence intensity, Fintravascular - Fmatrix, is a measure of the biodistribution. Real time measurements clearly showed that CP and UP fluorescence is associated with moving erythrocytes and not with endothelial cells of the vessel wall. Fluorescence intensity was monitored, up to 60 minutes after injection, by averaging the fluorescence over time intervals of 2 s and recording the integrated images. The fluorescence intensity reached its maximum in about 20 - 30 min after injection, presumably after monomerization inside erythrocyte membranes. The results are interpreted in terms of physical-chemical characteristics (e.g. hydrophilicity) and correlated with the photodynamically induced hemostasis in CAM blood vessels.
Transformer partial discharge monitoring based on optical fiber sensing
NASA Astrophysics Data System (ADS)
Wang, Kun; Tong, Xinglin; Zhu, Xiaolong
2014-06-01
The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the optical fiber sensing technology, we have done some research on fiber optics Fabry-Perot (FP) sensing which can be useful for the transformer on online partial discharge monitoring. This research aimed at improving the reliability of power system safety monitoring. We have done some work as follows: designing a set for fiber optics FP sensor preparation, according to the fabrication procedure strictly making out the sensors, building a reasonable signal demodulation system for fiber optics FP sensing, doing a preliminary analysis about online partial discharge signal monitoring, including the research on different discharge intensities with the same measuring distance and different measuring distances with the same discharge intensity, and then making a detailed analysis of the experimental results.
Physiologic Monitor Alarm Rates at 5 Children's Hospitals.
Schondelmeyer, Amanda C; Brady, Patrick W; Goel, Veena V; Cvach, Maria; Blake, Nancy; Mangeot, Colleen; Bonafide, Christopher P
2018-06-01
Alarm fatigue has been linked to patient morbidity and mortality in hospitals due to delayed or absent responses to monitor alarms. We sought to describe alarm rates at 5 freestanding children's hospitals during a single day and the types of alarms and proportions of patients monitored by using a point-prevalence, cross-sectional study design. We collected audible alarms on all inpatient units and calculated overall alarm rates and rates by alarm type per monitored patient per day. We found a total of 147,213 alarms during the study period, with 3-fold variation in alarm rates across hospitals among similar unit types. Across hospitals, onequarter of monitored beds were responsible for 71%, 61%, and 63% of alarms in medical-surgical, neonatal intensive care, and pediatric intensive care units, respectively. Future work focused on addressing nonactionable alarms in patients with the highest alarm counts may decrease alarm rates. © 2018 Society of Hospital Medicine.
An Updated Algorithm for Estimation of Pesticide Exposure Intensity in the Agricultural Health Study
An algorithm developed to estimate pesticide exposure intensity for use in epidemiologic analyses was revised based on data from two exposure monitoring studies. In the first study, we estimated relative exposure intensity based on the results of measurements taken during the app...
Assessment of SRS ambient air monitoring network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abbott, K.; Jannik, T.
Three methodologies have been used to assess the effectiveness of the existing ambient air monitoring system in place at the Savannah River Site in Aiken, SC. Effectiveness was measured using two metrics that have been utilized in previous quantification of air-monitoring network performance; frequency of detection (a measurement of how frequently a minimum number of samplers within the network detect an event), and network intensity (a measurement of how consistent each sampler within the network is at detecting events). In addition to determining the effectiveness of the current system, the objective of performing this assessment was to determine what, ifmore » any, changes could make the system more effective. Methodologies included 1) the Waite method of determining sampler distribution, 2) the CAP88- PC annual dose model, and 3) a puff/plume transport model used to predict air concentrations at sampler locations. Data collected from air samplers at SRS in 2015 compared with predicted data resulting from the methodologies determined that the frequency of detection for the current system is 79.2% with sampler efficiencies ranging from 5% to 45%, and a mean network intensity of 21.5%. One of the air monitoring stations had an efficiency of less than 10%, and detected releases during just one sampling period of the entire year, adding little to the overall network intensity. By moving or removing this sampler, the mean network intensity increased to about 23%. Further work in increasing the network intensity and simulating accident scenarios to further test the ambient air system at SRS is planned« less
Impact of treatment and monitoring on Prince George's County DWI's [sic
DOT National Transportation Integrated Search
1989-12-01
The state of Maryland maintains this nation's most intensive monitoring system for convicted drinking drivers. Each offender placed in the program by the court is required to attend a face-to-face interview once a week. In addition to the Monitor Pro...
An inexpensive open-source ultrasonic sensing system for monitoring fluid levels
USDA-ARS?s Scientific Manuscript database
Fluid levels are measured in a variety of agricultural applications, and are often measured manually, which can be time-consuming and labor-intensive. Rapid advances in electronic technologies have made a variety of inexpensive sensing, monitoring, and control capabilities available. A monitoring ...
Continuous noninvasive monitoring in the neonatal ICU.
Sahni, Rakesh
2017-04-01
Standard hemodynamic monitoring such as heart rate and systemic blood pressure may only provide a crude estimation of organ perfusion during neonatal intensive care. Pulse oximetry monitoring allows for continuous noninvasive monitoring of hemoglobin oxygenation and thus provides estimation of end-organ oxygenation. This review aims to provide an overview of pulse oximetry and discuss its current and potential clinical use during neonatal intensive care. Technological advances in continuous assessment of dynamic changes in systemic oxygenation with pulse oximetry during transition to extrauterine life and beyond provide additional details about physiological interactions among the key hemodynamic factors regulating systemic blood flow distribution along with the subtle changes that are frequently transient and undetectable with standard monitoring. Noninvasive real-time continuous systemic oxygen monitoring has the potential to serve as biomarkers for early-organ dysfunction, to predict adverse short-term and long-term outcomes in critically ill neonates, and to optimize outcomes. Further studies are needed to establish values predicting adverse outcomes and to validate targeted interventions to normalize abnormal values to improve outcomes.
Feehan, Lynne M; Goldsmith, Charles H; Leung, April Y F; Li, Linda C
Purpose: To compare the ability of SenseWear Mini (SWm) and Actigraph GT3X (AG 3 ) accelerometers to differentiate between healthy adults' observed sedentary and light activities in a laboratory setting. Methods: The 22 participants (15 women, 7 men), ages 19 to 72 years, wore SWm and AG 3 monitors and performed five sedentary and four light activities for 5 minutes each while observed in a laboratory setting. Performance was examined through comparisons of accuracy, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios. Correct identification of both types of activities was examined using area under the receiver operating characteristic curve (AUC). Results: Both monitors demonstrated excellent ability to identify sedentary activities (sensitivity>0.89). The SWm monitor was better at identifying light activities (specificity 0.61-0.71) than the AG 3 monitor (specificity 0.27-0.47) and thus also showed a greater ability to correctly identify both sedentary and light activities (SWm AUC 0.84; AG 3 AUC 0.62-0.73). Conclusions: SWm may be a more suitable monitor for detecting time spent in sedentary and light-intensity activities. This finding has clinical and research relevance for evaluation of time spent in lower intensity physical activities by sedentary adults.
The Significance of Forest Monitoring Programmes: the Finnish Perspective
NASA Astrophysics Data System (ADS)
Merila, P.; Derome, J.; Lindgren, M.
2007-12-01
Finland has been participating in the ICP Forests programme (the International Co-operative Programme on the Assessment and Monitoring of Air Pollution Effects on Forests) based on international agreements on the long- range transportation of air pollutants (LRTAP) and other associated monitoring programmes (e.g. Forest Focus, ICP Integrated Monitoring, ICP Vegetation) since 1985. The knowledge gained during the years has greatly increased our understanding of the overall condition of our forests and the factors affecting forest condition, the processes underlying forest ecosystem functioning, and the potential threats to our forests posed by human activities, both at home and abroad. The success of the monitoring activities in Finland is largely based on the experience gained during the early 1980's with our own national acidification project and, during the late 1980's and early 1990"s, in a number of regional monitoring projects. Finland's membership of the European Union (entry in 1996) has enabled us to further develop the infrastructure and coverage of both our extensive and intensive level networks. This broadening of our ecological understanding and development of international collaboration are now providing us with an invaluable basis for addressing the new monitoring challenges (biodiversity, climate change). The results gained in our monitoring activities clearly demonstrate the value of long-term monitoring programmes. The main results have been regularly reported both at the European (e.g. http://www.icp- forests.org/Reports.htm) and national level (e.g. http://www.metla.fi/julkaisut/workingpapers/2007/mwp045- en.htm). However, the datasets have not been intensively explored and exploited, and few of the important methodological and ecological findings have been published in peer-reviewed scientific journals. This has, understandably, not been the first priority of the international monitoring programmes. A number of the intensive forest monitoring plots in Finland have recently been included in LTER platforms, thus potentially increasing scientific collaboration between researchers across different governmental institutes and education bodies.
Coulter, D M
2001-12-01
The purpose of this paper is to describe how the New Zealand (NZ) Intensive Medicines Monitoring Programme (IMMP) functions in relation to NZ privacy laws and to describe the attitudes of patients to drug safety monitoring and the privacy of their personal and health information. The IMMP undertakes prospective observational event monitoring cohort studies on new drugs. The cohorts are established from prescription data and the events are obtained using prescription event monitoring and spontaneous reporting. Personal details, prescribing history of the monitored drugs and adverse events data are stored in databases long term. The NZ Health Information Privacy Code is outlined and the monitoring of sumatriptan is used to illustrate how the IMMP functions in relation to the Code. Patient responses to the programme are described. Sumatriptan was monitored in 14,964 patients and 107,646 prescriptions were recorded. There were 2344 reports received describing 3987 adverse events. A majority of the patients were involved in the recording of events data either personally or by telephone interview. There were no objections to the monitoring process on privacy grounds. Given the fact that all reasonable precautions are taken to ensure privacy, patients perceive drug safety to have greater priority than any slight risk of breach of confidentiality concerning their personal details and health information.
NASA Astrophysics Data System (ADS)
Bormann, H.; Faß, T.; Giertz, S.; Junge, B.; Diekkrüger, B.; Reichert, B.; Skowronek, A.
This paper presents the concept, first results and perspectives of the hydrological sub-project of the IMPETUS-Benin project which is part of the GLOWA program funded by the German ministry of education and research. In addition to the research concept, first results on field hydrology, pedology, hydrogeology and hydrological modelling are presented, focusing on the understanding of the actual hydrological processes. For analysing the processes a 30 km 2 catchment acting as a super test site was chosen which is assumed to be representative for the entire catchment of about 15,000 km 2. First results of the field investigations show that infiltration, runoff generation and soil erosion strongly depend on land cover and land use which again influence the soil properties significantly. A conceptual hydrogeological model has been developed summarising the process knowledge on runoff generation and subsurface hydrological processes. This concept model shows a dominance of fast runoff components (surface runoff and interflow), a groundwater recharge along preferential flow paths, temporary interaction between surface and groundwater and separate groundwater systems on different scales (shallow, temporary groundwater on local scale and permanent, deep groundwater on regional scale). The findings of intensive measurement campaigns on soil hydrology, groundwater dynamics and soil erosion have been integrated into different, scale-dependent hydrological modelling concepts applied at different scales in the target region (upper Ouémé catchment in Benin, about 15,000 km 2). The models have been applied and successfully validated. They will be used for integrated scenario analyses in the forthcoming project phase to assess the impacts of global change on the regional water cycle and on typical problem complexes such as food security in West African countries.
Saokaew, Surasak; Suwankesawong, Wimon; Permsuwan, Unchalee; Chaiyakunapruk, Nathorn
2011-04-01
The use of herbal products continues to expand rapidly across the world and concerns regarding the safety of these products have been raised. In Thailand, Thai Vigibase, developed by the Health Product Vigilance Center (HPVC) under the Thai Food and Drug Administration, is the national database that collates reports from health product surveillance systems and programmes. Thai Vigibase can be used to identify signals of adverse events in patients receiving herbal products. The purpose of the study was to describe the characteristics of reported adverse events in patients receiving herbal products in Thailand. Thai Vigibase data from February 2000 to December 2008 involving adverse events reported in association with herbal products were used. This database includes case reports submitted through the spontaneous reporting system and intensive monitoring programmes. Under the spontaneous reporting system, adverse event reports are collected nationwide via a national network of 22 regional centres covering more than 800 public and private hospitals, and health service centres. An intensive monitoring programme was also conducted to monitor the five single herbal products listed in the Thai National List of Essential Medicines (NLEM), while another intensive monitoring programme was developed to monitor the four single herbal products that were under consideration for inclusion in the NLEM. The database contained patient demographics, adverse events associated with herbal products, and details on seriousness, causality and quality of reports. Descriptive statistics were used for data analyses. A total of 593 reports with 1868 adverse events involving 24 different products were made during the study period. The age range of individuals was 1-86 years (mean 47 years). Most case reports were obtained from the intensive monitoring programme. Of the reports, 72% involved females. The herbal products for which adverse events were frequently reported were products containing turmeric (44%), followed by andrographis (10%), veld grape (10%), pennywort (7%), plai (6%), jewel vine (6%), bitter melon (5%) and snake plant (5%). Gastrointestinal problems were the most common adverse effect reported. Serious adverse events included Stevens-Johnson syndrome, anaphylactic shock and exfoliative dermatitis. Adverse event reports on herbals products were diverse, with most of them being reported through intensive monitoring programmes. Thai Vigibase is a potentially effective data source for signal detection of adverse events associated with herbal products.
On the Intensity Profile of Electric Lamps and Light Bulbs
ERIC Educational Resources Information Center
Bacalla, Xavier; Salumbides, Edcel John
2013-01-01
We demonstrate that the time profile of the light intensity from domestic lighting sources exhibits simple yet interesting properties that foster lively student discussions. We monitor the light intensity of an industrial fluorescent lamp (also known as TL) and an incandescent bulb using a photodetector connected to an oscilloscope. The light…
Presence/absence as a metric for monitoring vertebrate populations
Len Ruggiero; Dean Pearson
2000-01-01
Developing cost effective methods for monitoring vertebrate populations is a persistent problem in wildlife biology. Population demographic data is too costly and time intensive to acquire, so researchers have begun investigating presence/absence sampling as a means for monitoring wildlife populations. We examined three important assumptions regarding the probability...
Voltage and Current Measurements in HIFX Diodes
1977-08-01
Laboratories High- Intensity Flash X Ray Pacility. Sensitivities of these monitors have been measured to an accuracy of 10 percent or better by improved...importance of voltage (V) and current (1) monitors as a diagnostic tool for pulsed-electron beam machines such as High-Intensity Flash X Ray (HIFX) is well...15.4 2.7 109515. .2 7. - 3. 172.6 6.0 2.30 36. 4T. H. Martin, K. R. Prestwicht and D. L. Johnson, Summary of th e Hermes Flash X -Ray Program, Sandia
Method for monitoring irradiated fuel using Cerenkov radiation
Dowdy, E.J.; Nicholson, N.; Caldwell, J.T.
1980-05-21
A method is provided for monitoring irradiated nuclear fuel inventories located in a water-filled storage pond wherein the intensity of the Cerenkov radiation emitted from the water in the vicinity of the nuclear fuel is measured. This intensity is then compared with the expected intensity for nuclear fuel having a corresponding degree of irradiation exposure and time period after removal from a reactor core. Where the nuclear fuel inventory is located in an assembly having fuel pins or rods with intervening voids, the Cerenkov light intensity measurement is taken at selected bright sports corresponding to the water-filled interstices of the assembly in the water storage, the water-filled interstices acting as Cerenkov light channels so as to reduce cross-talk. On-line digital analysis of an analog video signal is possible, or video tapes may be used for later measurement using a video editor and an electrometer. Direct measurement of the Cerenkov radiation intensity also is possible using spot photometers pointed at the assembly.
NASA Astrophysics Data System (ADS)
Zhang, Yin; Chen, Jie; Li, Yadong; Seo, Hyo Jin
2014-11-01
β-Dicalcium silicate (β-Ca2SiO4) doped with Eu3+ was synthesized by sol-gel method. The luminescence intensity of the mineralization products formed during the hydroxyapatite (Ca10(PO4)6(OH)2, HA) conversion of Eu3+-doped β-Ca2SiO4, in 0.25 M K2HPO4 solution, were detected using luminescence spectroscopy. The results indicated that the luminescence intensity of Eu3+ ion gradually depressed with prolonged mineralization time, and it could hardly be detected with the complete transformation from β-Ca2SiO4:Eu3+ to hydroxyapatite. The change of Eu3+ ionic concentrations in the mineralization products and the final solutions after conversion reaction, were further examined using energy-dispersive X-ray and inductively-coupled plasma mass spectrometry, respectively. This suggested that the process of mineralization can be monitored with the luminescence intensity of Eu3+ ions in the mineralization products. The current study will open up a new and simple in vivo avenue for in situ monitoring hydroxyapatite conversion with a fiber luminescence spectrometer.
Estimated energy expenditure of nursing assistants in long term care.
Olson, Darcie L; King, Phyllis M
2012-01-01
Ergonomic research on nursing work has focused primarily on the biomechanical analysis of patient handling tasks. Few studies have addressed the intensity of a full day of nursing work as measured by changes in heart rate and energy expenditure. A pilot study was conducted between August 2009 and May 2010 to examine the intensity of performing nursing assistant work in long term care settings and to assess the usefulness of heart rate monitoring as a measure of work intensity. The residents of the facilities were physically dependent adults. The settings had floor-based mechanical lifting devices available and no-lift policies that restricted workers from lifting. Eight women between the ages of 19 and 54 from two facilities participated in this study. A wearable recorder allowed unobtrusive heart rate monitoring while nursing assistants worked their usual shift. Continuous heart rate monitoring for a full shift provided an estimation of energy expenditure. The data suggest that the nursing assistants worked at a moderate level yet were within the safe work intensity level recommended by NIOSH [32]. The information provides preliminary baseline data for nursing assistants who work with physically dependent adults using floor-based lifts in a no-lift environment.
Spectral entropy in monitoring anesthetic depth.
Escontrela Rodríguez, B; Gago Martínez, A; Merino Julián, I; Martínez Ruiz, A
2016-10-01
Monitoring the brain response to hypnotics in general anesthesia, with the nociceptive and hemodynamic stimulus interaction, has been a subject of intense investigation for many years. Nowadays, monitors of depth of anesthesia are based in processed electroencephalogram by different algorithms, some of them unknown, to obtain a simplified numeric parameter approximate to brain activity state in each moment. In this review we evaluate if spectral entropy suitably reflects the brain electric behavior in response to hypnotics and the different intensity nociceptive stimulus effect during a surgical procedure. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Method for monitoring the crystallization of an organic material from a liquid
Asay, Blaine W.; Henson, Bryan F.; Sander, Robert K.; Robinson, Jeanne M.; Son, Steven F.; Dickson, Peter M.
2004-10-05
Method for monitoring the crystallization of at least one organic material from a liquid. According to the method, a liquid having at least one organic material capable of existing in at least one non-centrosymmetric phase is prepared. The liquid is interrogated with a laser beam at a chosen wavelength. As at least a portion of the at least one organic material crystallizes from the liquid, the intensity of any light scattered by the crystallized material at a wavelength equal to one-half the chosen wavelength of the interrogating laser beam is monitored. If the intensity of this scattered light, increases, then the crystals that form include at least one non-cetrosymmetric phase.
Thompson, Dylan; Batterham, Alan M; Peacock, Oliver J; Western, Max J; Booso, Rahuman
2016-10-01
Wearable devices to self-monitor physical activity have become popular with individuals and healthcare practitioners as a route to the prevention of chronic disease. It is not currently possible to reconcile feedback from these devices with activity recommendations because the guidelines refer to the amount of activity required on top of normal lifestyle activities (e.g., 150 minutes of moderate-to-vigorous intensity activity per week over-and-above normal moderate-to-vigorous lifestyle activities). The aim of this study was to recalibrate the feedback from self-monitoring. We pooled data from four studies conducted between 2006 and 2014 in patients and volunteers from the community that included both sophisticated measures of physical activity and 10-year risk for cardiovascular disease and type 2 diabetes (n=305). We determined the amount of moderate-to-vigorous intensity activity that corresponded to FAO/WHO/UNU guidance for a required PAL of 1.75 (Total Energy Expenditure/Basal Metabolic Rate). Our results show that, at the UK median PAL, total moderate-to-vigorous intensity physical activity will be around 735 minutes per week (~11% of waking time). We estimate that a 4% increase in moderate-to-vigorous intensity activity will achieve standardised guidance from FAO/WHO/UNU and will require ~1000 minutes of moderate-to-vigorous intensity activity per week. This study demonstrates that feedback from sophisticated wearable devices is incompatible with current physical activity recommendations. Without adjustment, people will erroneously form the view that they are exceeding recommendations by several fold. A more appropriate target from self-monitoring that accounts for normal moderate-to-vigorous lifestyle activities is ~1000 minutes per week, which represents ~15% of waking time. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Sharp-Tailed Grouse Nest Survival and Nest Predator Habitat Use in North Dakota's Bakken Oil Field.
Burr, Paul C; Robinson, Aaron C; Larsen, Randy T; Newman, Robert A; Ellis-Felege, Susan N
2017-01-01
Recent advancements in extraction technologies have resulted in rapid increases of gas and oil development across the United States and specifically in western North Dakota. This expansion of energy development has unknown influences on local wildlife populations and the ecological interactions within and among species. Our objectives for this study were to evaluate nest success and nest predator dynamics of sharp-tailed grouse (Tympanuchus phasianellus) in two study sites that represented areas of high and low energy development intensities in North Dakota. During the summers of 2012 and 2013, we monitored 163 grouse nests using radio telemetry. Of these, 90 nests also were monitored using miniature cameras to accurately determine nest fates and identify nest predators. We simultaneously conducted predator surveys using camera scent stations and occupancy modeling to estimate nest predator occurrence at each site. American badgers (Taxidea taxus) and striped skunks (Mephitis mephitis) were the primary nest predators, accounting for 56.7% of all video recorded nest depredations. Nests in our high intensity gas and oil area were 1.95 times more likely to succeed compared to our minimal intensity area. Camera monitored nests were 2.03 times more likely to succeed than non-camera monitored nests. Occupancy of mammalian nest predators was 6.9 times more likely in our study area of minimal gas and oil intensity compared to the high intensity area. Although only a correlative study, our results suggest energy development may alter the predator community, thereby increasing nest success for sharp-tailed grouse in areas of intense development, while adjacent areas may have increased predator occurrence and reduced nest success. Our study illustrates the potential influences of energy development on the nest predator-prey dynamics of sharp-tailed grouse in western North Dakota and the complexity of evaluating such impacts on wildlife.
Post-marketing safety monitoring of a new group B meningococcal vaccine in New Zealand, 2004-2006.
McNicholas, Anne; Galloway, Yvonne; Stehr-Green, Paul; Reid, Stewart; Radke, Sarah; Sexton, Kerry; Kieft, Charlotte; Macdonald, Claire; Neutze, Jocelyn; Drake, Ross; Isaac, Dorothy; O'Donnell, Mary; Tatley, Michael; Oster, Philipp; O'Hallahan, Jane
2007-01-01
New Zealand introduced a new outer membrane vesicle vaccine in 2004 to combat an epidemic of group B meningococcal disease. An Independent Safety Monitoring Board oversaw intensive safety monitoring, which included hospital surveillance, health professional reporting (passive and active) and mortality monitoring. With over three million doses administered to individuals aged under 20 years, the monitoring results provide consistent evidence supporting the vaccine's safety.
Zampieri, Fernando Godinho; Soares, Márcio; Borges, Lunna Perdigão; Salluh, Jorge Ibrain Figueira; Ranzani, Otávio Tavares
2017-01-01
To describe the Epimed Monitor Database®, a Brazilian intensive care unit quality improvement database. We described the Epimed Monitor® Database, including its structure and core data. We presented aggregated informative data from intensive care unit admissions from 2010 to 2016 using descriptive statistics. We also described the expansion and growth of the database along with the geographical distribution of participating units in Brazil. The core data from the database includes demographic, administrative and physiological parameters, as well as specific report forms used to gather detailed data regarding the use of intensive care unit resources, infectious episodes, adverse events and checklists for adherence to best clinical practices. As of the end of 2016, 598 adult intensive care units in 318 hospitals totaling 8,160 intensive care unit beds were participating in the database. Most units were located at private hospitals in the southeastern region of the country. The number of yearly admissions rose during this period and included a predominance of medical admissions. The proportion of admissions due to cardiovascular disease declined, while admissions due to sepsis or infections became more common. Illness severity (Simplified Acute Physiology Score - SAPS 3 - 62 points), patient age (mean = 62 years) and hospital mortality (approximately 17%) remained reasonably stable during this time period. A large private database of critically ill patients is feasible and may provide relevant nationwide epidemiological data for quality improvement and benchmarking purposes among the participating intensive care units. This database is useful not only for administrative reasons but also for the improvement of daily care by facilitating the adoption of best practices and use for clinical research.
NASA Astrophysics Data System (ADS)
De Siena, Luca; Sketsiou, Panayiota
2017-04-01
We plan the application of a joint velocity, attenuation, and scattering tomography to the North Sea basins. By using seismic phases and intensities from previous passive and active surveys our aim is to image and monitor fluids under the subsurface. Seismic intensities provide unique solutions to the problem of locating/tracking gas/fluid movements in the volcanoes and depicting sub-basalt and sub-intrusives in volcanic reservoirs. The proposed techniques have been tested in volcanic Islands (Deception Island), continental calderas (Campi Flegrei) and Quaternary Volcanoes (Mount. St. Helens) and have been proved effective at monitoring fracture opening, imaging buried fluid-filled bodies, and tracking water/gas interfaces. These novel seismic attributes are modelled in space and time and connected with the lithology of the sampled medium, specifically density and permeability, with as key output a novel computational code with strong commercial potential. Data are readily available in the framework of the NERC CDT Oil & Gas project.
CMOS image sensors as an efficient platform for glucose monitoring.
Devadhasan, Jasmine Pramila; Kim, Sanghyo; Choi, Cheol Soo
2013-10-07
Complementary metal oxide semiconductor (CMOS) image sensors have been used previously in the analysis of biological samples. In the present study, a CMOS image sensor was used to monitor the concentration of oxidized mouse plasma glucose (86-322 mg dL(-1)) based on photon count variation. Measurement of the concentration of oxidized glucose was dependent on changes in color intensity; color intensity increased with increasing glucose concentration. The high color density of glucose highly prevented photons from passing through the polydimethylsiloxane (PDMS) chip, which suggests that the photon count was altered by color intensity. Photons were detected by a photodiode in the CMOS image sensor and converted to digital numbers by an analog to digital converter (ADC). Additionally, UV-spectral analysis and time-dependent photon analysis proved the efficiency of the detection system. This simple, effective, and consistent method for glucose measurement shows that CMOS image sensors are efficient devices for monitoring glucose in point-of-care applications.
A remote drip infusion monitoring system employing Bluetooth.
Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Caldwell, W Morton
2012-01-01
We have developed a remote drip infusion monitoring system for use in hospitals. The system consists of several infusion monitoring devices and a central monitor. The infusion monitoring device employing a Bluetooth module can detect the drip infusion rate and an empty infusion solution bag, and then these data are sent to the central monitor placed at the nurses' station via the Bluetooth. The central monitor receives the data from several infusion monitoring devices and then displays graphically them. Therefore, the developed system can monitor intensively the drip infusion situation of the several patients at the nurses' station.
Application of pixel-cell detector technology for Advanced Neutron Beam Monitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopp, Daniel M.
2011-01-11
Application of Pixel-Cell Detector Technology for Advanced Neutron Beam Monitors Specifications of currently available neutron beam detectors limit their usefulness at intense neutron beams of large-scale national user facilities used for the advanced study of materials. A large number of neutron-scattering experiments require beam monitors to operate in an intense neutron beam flux of >10E+7 neutrons per second per square centimeter. For instance, a 4 cm x 4 cm intense beam flux of 6.25 x 10E+7 n/s/cm2 at the Spallation Neutron Source will put a flux of 1.00 x 10E+9 n/s at the beam monitor. Currently available beam monitors withmore » a typical efficiency of 1 x 10E-4 will need to be replaced in less than two years of operation due to wire and gas degradation issues. There is also a need at some instruments for beam position information that are beyond the capabilities of currently available He-3 and BF3 neutron beam monitors. ORDELA, Inc.’s research under USDOE SBIR Grant (DE-FG02-07ER84844) studied the feasibility of using pixel-cell technology for developing a new generation of stable, long-life neutron beam monitors. The research effort has led to the development and commercialization of advanced neutron beam detectors that will directly benefit the Spallation Neutron Source and other intense neutron sources such as the High Flux Isotope Reactor. A prototypical Pixel-Cell Neutron Beam Monitor was designed and constructed during this research effort. This prototype beam monitor was exposed to an intense neutron beam at the HFIR SNS HB-2 test beam site. Initial measurements on efficiency, uniformity across the detector, and position resolution yielded excellent results. The development and test results have provided the required data to initiate the fabrication and commercialization of this next generation of neutron-detector systems. ORDELA, Inc. has (1) identified low-cost design and fabrication strategies, (2) developed and built pixel-cell detectors and instrumented a 64-pixel-cell detector to specifications for the Cold-Neutron Chopper Spectrometer and POWGEN instruments, (3) investigated the general characteristics of this technology, (4) studied pixel-cell configurations and arrived at an optimized modular design, and (5) evaluated fabrication costs of mass production for these configurations. The resulting technology will enable a complete line of pixel-cell-based neutron detectors to be commercially under available. ORDELA, Inc has a good track history of application of innovative technology into the marketplace. Our commercialization record reflects this. For additional information, please contact Daniel Kopp at ORDELA, Inc. at +1 (865) 483-8675 or check our website at www.ordela.com.« less
The Accuracy and Validity of iOS-Based Heart Rate Apps During Moderate to High Intensity Exercise.
Bouts, Alexa M; Brackman, Lauren; Martin, Elizabeth; Subasic, Adam M; Potkanowicz, Edward S
2018-01-01
People use their smartphones for everything from web browsing to tracking fitness metrics. However, it is unclear whether smartphone-based apps that use photoplethysmography to measure heart rate are an accurate or valid measure of exercise intensity. Purpose was to determine the accuracy and validity of two iOS-based heart rate monitors, Runtastic Heart Rate Monitor and Pulse Tracker PRO by Runtastic (Runtastic) and Instant Heart Rate+: Heart Rate and Pulse Monitor by Azumio (Instant Heart Rate), when compared to the electrocardiogram (ECG) and Polar® T31 uncoded heart rate monitor from moderate to vigorous intensity exercise. Participants were 15 male and female regularly active college students. Pre-exercise heart rate and blood pressure were recorded and then participants exercised on a stationary bike at a pedal rate of between 50-60 rpms. After completing a warm-up stage at 40% of age estimated maximum heart rate (AEMHR), exercise intensity progressed from 50% of AEMHR through to 85% of AEMHR in eight, 5-minute stages. At the end of each stage, and having achieved steady-state, heart rates were recorded from each apparatus. After completing the final stage, participants completed a cooldown at 40% of their AEMHR. Post-exercise heart rate and blood pressure were also recorded to ensure full recovery to baseline. There was a strong positive correlation between the Polar® monitor and the ECG during all stages. However, there were not strong correlations for either of the smartphone-based apps at any time point. Although there were weak correlations between the smartphone-based apps and ECG and Polar®, further studies need to be conducted to determine if inaccuracy is due to user error (finger placement, finger temperature, etc.) or the technology behind the apps.
The Accuracy and Validity of iOS-Based Heart Rate Apps During Moderate to High Intensity Exercise
BOUTS, ALEXA M.; BRACKMAN, LAUREN; MARTIN, ELIZABETH; SUBASIC, ADAM M.; POTKANOWICZ, EDWARD S.
2018-01-01
People use their smartphones for everything from web browsing to tracking fitness metrics. However, it is unclear whether smartphone-based apps that use photoplethysmography to measure heart rate are an accurate or valid measure of exercise intensity. Purpose was to determine the accuracy and validity of two iOS-based heart rate monitors, Runtastic Heart Rate Monitor and Pulse Tracker PRO by Runtastic (Runtastic) and Instant Heart Rate+: Heart Rate and Pulse Monitor by Azumio (Instant Heart Rate), when compared to the electrocardiogram (ECG) and Polar® T31 uncoded heart rate monitor from moderate to vigorous intensity exercise. Participants were 15 male and female regularly active college students. Pre-exercise heart rate and blood pressure were recorded and then participants exercised on a stationary bike at a pedal rate of between 50–60 rpms. After completing a warm-up stage at 40% of age estimated maximum heart rate (AEMHR), exercise intensity progressed from 50% of AEMHR through to 85% of AEMHR in eight, 5-minute stages. At the end of each stage, and having achieved steady-state, heart rates were recorded from each apparatus. After completing the final stage, participants completed a cooldown at 40% of their AEMHR. Post-exercise heart rate and blood pressure were also recorded to ensure full recovery to baseline. There was a strong positive correlation between the Polar® monitor and the ECG during all stages. However, there were not strong correlations for either of the smartphone-based apps at any time point. Although there were weak correlations between the smartphone-based apps and ECG and Polar®, further studies need to be conducted to determine if inaccuracy is due to user error (finger placement, finger temperature, etc.) or the technology behind the apps. PMID:29541341
NASA Astrophysics Data System (ADS)
Liu, L.; Huang, Zh.; Qiu, Zh.; Li, B.
2018-01-01
A handheld RGB camera was developed to monitor the in vivo distribution of porphyrin-based photosensitizer (PS) hematoporphyrin monomethyl ether (HMME) in blood vessels during photodynamic therapy (PDT). The focal length, f-number, International Standardization Organization (ISO) sensitivity, and shutter speed of the camera were optimized for the solution sample with various HMME concentrations. After the parameter optimization, it was found that the red intensity value of the fluorescence image was linearly related to the fluorescence intensity under investigated conditions. The RGB camera was then used to monitor the in vivo distribution of HMME in blood vessels in a skin-fold window chamber model. The red intensity value of the recorded RGB fluorescence image was found to be linearly correlated to HMME concentrations in the range 0-24 μM. Significant differences in the red to green intensity ratios were observed between the blood vessels and the surrounding tissue.
Intensity of Territorial Marking Predicts Wolf Reproduction: Implications for Wolf Monitoring
García, Emilio J.
2014-01-01
Background The implementation of intensive and complex approaches to monitor large carnivores is resource demanding, restricted to endangered species, small populations, or small distribution ranges. Wolf monitoring over large spatial scales is difficult, but the management of such contentious species requires regular estimations of abundance to guide decision-makers. The integration of wolf marking behaviour with simple sign counts may offer a cost-effective alternative to monitor the status of wolf populations over large spatial scales. Methodology/Principal Findings We used a multi-sampling approach, based on the collection of visual and scent wolf marks (faeces and ground scratching) and the assessment of wolf reproduction using howling and observation points, to test whether the intensity of marking behaviour around the pup-rearing period (summer-autumn) could reflect wolf reproduction. Between 1994 and 2007 we collected 1,964 wolf marks in a total of 1,877 km surveyed and we searched for the pups' presence (1,497 howling and 307 observations points) in 42 sampling sites with a regular presence of wolves (120 sampling sites/year). The number of wolf marks was ca. 3 times higher in sites with a confirmed presence of pups (20.3 vs. 7.2 marks). We found a significant relationship between the number of wolf marks (mean and maximum relative abundance index) and the probability of wolf reproduction. Conclusions/Significance This research establishes a real-time relationship between the intensity of wolf marking behaviour and wolf reproduction. We suggest a conservative cutting point of 0.60 for the probability of wolf reproduction to monitor wolves on a regional scale combined with the use of the mean relative abundance index of wolf marks in a given area. We show how the integration of wolf behaviour with simple sampling procedures permit rapid, real-time, and cost-effective assessments of the breeding status of wolf packs with substantial implications to monitor wolves at large spatial scales. PMID:24663068
ERIC Educational Resources Information Center
Wang, Zhanjun; Qiao, Weifeng; Li, Jiangbo
2016-01-01
Higher education monitoring evaluation is a process that uses modern information technology to continually collect and deeply analyze relevant data, visually present the state of higher education, and provide an objective basis for value judgments and scientific decision making by diverse bodies Higher education monitoring evaluation is…
Yagi, Shigeru; Iwanaga, Takeshi; Kojima, Hiroshi; Shoji, Yoshio; Suzuki, Seiji; Seno, Kunihiro; Mori, Hisayoshi; Tokura, Yoshiki; Takigawa, Masahiro; Moriwaki, Shin-Ichi
2002-12-01
We have developed a UV monitor with polycrystalline (poly-) gallium nitride (GaN) UV sensors and evaluated its performance from the viewpoint of its effectiveness for use with photosensitive dermatosis patients. The poly-GaN UV sensor is sensitive to UV light from 280 to 410 nm even without optical filters. The UV monitor is a portable self-data-acquisition instrument with a minimum detection level (defined as average UV intensity over 290 to 400 nm) of 2 microW/cm2 and can store UV dose data for 128 days. It allows easy measurement of four orders of magnitude of ambient UV intensity and dose from indoor light to direct solar radiation in summer. Trial use of the UV monitor by five xeroderma pigmentosum patients started in June 2000 and was carried out for 1 year. It was demonstrated that the UV monitor was useful in improving their quality of life.
Mesraoua, Boulenouar; Wieser, Heinz G
2009-10-01
Continuous EEG (cEEG) monitoring in the intensive care unit (ICU) is essential for detecting non-convulsive seizures/status epilepticus (NCSs, NCSE). Currently there exist a number of continuous EEG monitoring systems adapted for use in the ICU. However, these systems have been trained using EEG data collected from healthy, neurologically intact patients with epileptic seizures, a very different patient population from ICU patients. The review consists of 2 parts, clinical and technological aspects. In the first one, we summarize the electroencephalographic aspects of NCSs/NCSE and other EEG patterns encountered in the ICU. In the second part, we explain how to develop a novel cEEG monitoring system to be used in Hamad Medical Corporation ICUs, Doha, Qatar, that is able to detect pathological EEG patterns commonly occurring in the critically ill patient. Real-time monitoring of seizure discharges, and other pathological EEG patterns will allow correct diagnosis and adequate treatment in a timely fashion.
Continuous intra-arterial blood-gas monitoring
NASA Astrophysics Data System (ADS)
Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.
1993-05-01
Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.
Review and assessment of the database and numerical modeling for turbine heat transfer
NASA Technical Reports Server (NTRS)
Gladden, H. J.; Simoneau, R. J.
1988-01-01
The objectives of the HOST Turbine Heat Transfer subproject were to obtain a better understanding of the physics of the aerothermodynamic phenomena and to assess and improve the analytical methods used to predict the flow and heat transfer in high-temperature gas turbines. At the time the HOST project was initiated, an across-the-board improvement in turbine design technology was needed. A building-block approach was utilized and the research ranged from the study of fundamental phenomena and modeling to experiments in simulated real engine environments. Experimental research accounted for approximately 75 percent of the funding while the analytical efforts were approximately 25 percent. A healthy government/industry/university partnership, with industry providing almost half of the research, was created to advance the turbine heat transfer design technology base.
SLHC, the High-Luminosity Upgrade (public event)
None
2017-12-09
In the morning of June 23rd a public event is organised in CERN's Council Chamber with the aim of providing the particle physics community with up-to-date information about the strategy for the LHC luminosity upgrade and to describe the current status of preparation work. The presentations will provide an overview of the various accelerator sub-projects, the LHC physics prospects and the upgrade plans of ATLAS and CMS. This event is organised in the framework of the SLHC-PP project, which receives funding from the European Commission for the preparatory phase of the LHC High Luminosity Upgrade project. Informing the public is among the objectives of this EU-funded project. A simultaneous transmission of this meeting will be broadcast, available at the following address: http://webcast.cern.ch/
Delpla, Ianis; Florea, Mihai; Pelletier, Geneviève; Rodriguez, Manuel J
2018-06-04
Trihalomethanes (THMs) and Haloacetic Acids (HAAs) are the main groups detected in drinking water and are consequently strictly regulated. However, the increasing quantity of data for disinfection byproducts (DBPs) produced from research projects and regulatory programs remains largely unexploited, despite a great potential for its use in optimizing drinking water quality monitoring to meet specific objectives. In this work, we developed a procedure to optimize locations and periods for DBPs monitoring based on a set of monitoring scenarios using the cluster analysis technique. The optimization procedure used a robust set of spatio-temporal monitoring results on DBPs (THMs and HAAs) generated from intensive sampling campaigns conducted in a residential sector of a water distribution system. Results shows that cluster analysis allows for the classification of water quality in different groups of THMs and HAAs according to their similarities, and the identification of locations presenting water quality concerns. By using cluster analysis with different monitoring objectives, this work provides a set of monitoring solutions and a comparison between various monitoring scenarios for decision-making purposes. Finally, it was demonstrated that the data from intensive monitoring of free chlorine residual and water temperature as DBP proxy parameters, when processed using cluster analysis, could also help identify the optimal sampling points and periods for regulatory THMs and HAAs monitoring. Copyright © 2018 Elsevier Ltd. All rights reserved.
Laurinaviciene, Aida; Plancoulaine, Benoit; Baltrusaityte, Indra; Meskauskas, Raimundas; Besusparis, Justinas; Lesciute-Krilaviciene, Daiva; Raudeliunas, Darius; Iqbal, Yasir; Herlin, Paulette; Laurinavicius, Arvydas
2014-01-01
Digital immunohistochemistry (IHC) is one of the most promising applications brought by new generation image analysis (IA). While conventional IHC staining quality is monitored by semi-quantitative visual evaluation of tissue controls, IA may require more sensitive measurement. We designed an automated system to digitally monitor IHC multi-tissue controls, based on SQL-level integration of laboratory information system with image and statistical analysis tools. Consecutive sections of TMA containing 10 cores of breast cancer tissue were used as tissue controls in routine Ki67 IHC testing. Ventana slide label barcode ID was sent to the LIS to register the serial section sequence. The slides were stained and scanned (Aperio ScanScope XT), IA was performed by the Aperio/Leica Colocalization and Genie Classifier/Nuclear algorithms. SQL-based integration ensured automated statistical analysis of the IA data by the SAS Enterprise Guide project. Factor analysis and plot visualizations were performed to explore slide-to-slide variation of the Ki67 IHC staining results in the control tissue. Slide-to-slide intra-core IHC staining analysis revealed rather significant variation of the variables reflecting the sample size, while Brown and Blue Intensity were relatively stable. To further investigate this variation, the IA results from the 10 cores were aggregated to minimize tissue-related variance. Factor analysis revealed association between the variables reflecting the sample size detected by IA and Blue Intensity. Since the main feature to be extracted from the tissue controls was staining intensity, we further explored the variation of the intensity variables in the individual cores. MeanBrownBlue Intensity ((Brown+Blue)/2) and DiffBrownBlue Intensity (Brown-Blue) were introduced to better contrast the absolute intensity and the colour balance variation in each core; relevant factor scores were extracted. Finally, tissue-related factors of IHC staining variance were explored in the individual tissue cores. Our solution enabled to monitor staining of IHC multi-tissue controls by the means of IA, followed by automated statistical analysis, integrated into the laboratory workflow. We found that, even in consecutive serial tissue sections, tissue-related factors affected the IHC IA results; meanwhile, less intense blue counterstain was associated with less amount of tissue, detected by the IA tools.
2014-01-01
Background Digital immunohistochemistry (IHC) is one of the most promising applications brought by new generation image analysis (IA). While conventional IHC staining quality is monitored by semi-quantitative visual evaluation of tissue controls, IA may require more sensitive measurement. We designed an automated system to digitally monitor IHC multi-tissue controls, based on SQL-level integration of laboratory information system with image and statistical analysis tools. Methods Consecutive sections of TMA containing 10 cores of breast cancer tissue were used as tissue controls in routine Ki67 IHC testing. Ventana slide label barcode ID was sent to the LIS to register the serial section sequence. The slides were stained and scanned (Aperio ScanScope XT), IA was performed by the Aperio/Leica Colocalization and Genie Classifier/Nuclear algorithms. SQL-based integration ensured automated statistical analysis of the IA data by the SAS Enterprise Guide project. Factor analysis and plot visualizations were performed to explore slide-to-slide variation of the Ki67 IHC staining results in the control tissue. Results Slide-to-slide intra-core IHC staining analysis revealed rather significant variation of the variables reflecting the sample size, while Brown and Blue Intensity were relatively stable. To further investigate this variation, the IA results from the 10 cores were aggregated to minimize tissue-related variance. Factor analysis revealed association between the variables reflecting the sample size detected by IA and Blue Intensity. Since the main feature to be extracted from the tissue controls was staining intensity, we further explored the variation of the intensity variables in the individual cores. MeanBrownBlue Intensity ((Brown+Blue)/2) and DiffBrownBlue Intensity (Brown-Blue) were introduced to better contrast the absolute intensity and the colour balance variation in each core; relevant factor scores were extracted. Finally, tissue-related factors of IHC staining variance were explored in the individual tissue cores. Conclusions Our solution enabled to monitor staining of IHC multi-tissue controls by the means of IA, followed by automated statistical analysis, integrated into the laboratory workflow. We found that, even in consecutive serial tissue sections, tissue-related factors affected the IHC IA results; meanwhile, less intense blue counterstain was associated with less amount of tissue, detected by the IA tools. PMID:25565007
Development of bunch shape monitor for high-intensity beam on the China ADS proton LINAC Injector II
NASA Astrophysics Data System (ADS)
Zhu, Guangyu; Wu, Junxia; Du, Ze; Zhang, Yong; Xue, Zongheng; Xie, Hongming; Wei, Yuan; Jing, Long; Jia, Huan
2018-05-01
The development, performance, and testing of the longitudinal bunch shape monitor, namely, the Fast Faraday Cup (FFC), are presented in this paper. The FFC is an invasive instrument controlled by a stepper motor, and its principle of operation is based on a strip line structure. The longitudinal bunch shape was determined by sampling a small part of the beam hitting the strip line through a 1-mm hole. The rise time of the detector reached 24 ps. To accommodate experiments that utilize high-intensity beams, the materials of the bunch shape monitor were chosen to sustain high temperatures. Water cooling was also integrated in the detector system to enhance heat transfer and prevent thermal damage. We also present an analysis of the heating caused by the beam. The bunch shape monitor has been installed and commissioned at the China ADS proton LINAC Injector II.
The LIFE child study: a life course approach to disease and health
2012-01-01
Background Profound knowledge about child growth, development, health, and disease in contemporary children and adolescents is still rare. Epidemiological studies together with new powerful research technologies present exciting opportunities to the elucidation of risk factor-outcome associations with potentially major consequences for prevention, diagnosis and treatment. Aim To conduct a unique prospective longitudinal cohort study in order to assess how environmental, metabolic and genetic factors affect growth, development and health from fetal life to adulthood. Methods The ‘Leipzig Research Centre for Civilization Diseases (LIFE) Child Study’ focuses on two main research objectives: (1) monitoring of normal growth, development and health; (2) non-communicable diseases such as childhood obesity and its co-morbidities, atopy and mental health problems. Detailed assessments will be conducted alongside long-term storage of biological samples in 2,000 pregnant women and more than 10,000 children and their families. Results Close coordination and engagement of a multidisciplinary team in the LIFE Child study successfully established procedures and systems for balancing many competing study and ethical needs. Full participant recruitment and complete data collection started in July 2011. Early data indicate a high acceptance rate of the study program, successful recruitment strategies and the establishment of a representative cohort for the population of Leipzig. A series of subprojects are ongoing, and analyses and publications are on their way. Discussion This paper addresses key elements in the design and implementation of the new prospective longitudinal cohort study LIFE Child. Given the recognized need for long-term data on adverse effects on health and protective factors, our study data collection should provide magnificent opportunities to examine complex interactions that govern the emergence of non-communicable diseases. PMID:23181778
NASA Astrophysics Data System (ADS)
Galloway, D. L.; Carreon-Freyre, D.; Teatini, P.; Ye, S.
2015-12-01
Subsidence is globally prevalent and because much of it is related to hydrological processes affected by human development of local land and water resources, "Land Subsidence" was included in the UNESCO programme of the International Hydrological Decade (IHD), 1965-1974 and an ad hoc working group on land subsidence was formed. In 1975 subsidence was retained under the framework of the UNESCO IHP (subproject 8.4: "Investigation of Land Subsidence due to Groundwater Exploitation"), and UNESCO IHP formerly codified the Working Group on Land Subsidence (WGLS). In 1984 the WGLS produced a comprehensive guidebook to serve scientists and engineers, confronting land subsidence problems, particularly in developing countries (http://unesdoc.unesco.org/$other/unesdoc/pdf/065167eo.pdf). During the IHD, UNESCO IHP convened the 1st International Symposium on Land Subsidence in 1969 in Tokyo, Japan. In collaboration with UNESCO IHP, IAHS, and other scientific organizations, the WGLS has convened eight more International Symposia on Land Subsidence in different countries in Asia, Europe and North America. The 9 published symposia proceedings constitute an important source of global subsidence research and case studies during the past 45 years, covering both anthropogenic and natural subsidence processes. Currently, the WGLS comprising 20 subsidence experts from 9 countries promotes and facilitates the international exchange of information regarding the design, implementation and evaluation of risk assessments and mitigation measures, the definition of water and land resource-management strategies that support sustainable development in areas vulnerable to subsidence (http://landsubsidence-unesco.org), and the assessment of related geological risks such as earth fissuring and fault activation (www.igcp641.org). The WGLS has become an important global leader in promoting subsidence awareness, scientific research and its application to subsidence monitoring, analysis and management.
Baker, Andy; Ward, David; Lieten, Shakti H; Periera, Ryan; Simpson, Ellie C; Slater, Malcolm
2004-07-01
Protein-like fluorescence intensity in rivers increases with increasing anthropogenic DOM inputs from sewerage and farm wastes. Here, a portable luminescence spectrophotometer was used to investigate if this technology could be used to provide both field scientists with a rapid pollution monitoring tool and process control engineers with a portable waste water monitoring device, through the measurement of river and waste water tryptophan-like fluorescence from a range of rivers in NE England and from effluents from within two waste water treatment plants. The portable spectrophotometer determined that waste waters and sewerage effluents had the highest tryptophan-like fluorescence intensity, urban streams had an intermediate tryptophan-like fluorescence intensity, and the upstream river samples of good water quality the lowest tryptophan-like fluorescence intensity. Replicate samples demonstrated that fluorescence intensity is reproducible to +/- 20% for low fluorescence, 'clean' river water samples and +/- 5% for urban water and waste waters. Correlations between fluorescence measured by the portable spectrophotometer with a conventional bench machine were 0.91; (Spearman's rho, n = 143), demonstrating that the portable spectrophotometer does correlate with tryptophan-like fluorescence intensity measured using the bench spectrophotometer.
Detection and monitoring of invasive exotic plants: a comparison of four sampling methods
Cynthia D. Huebner
2007-01-01
The ability to detect and monitor exotic invasive plants is likely to vary depending on the sampling method employed. Methods with strong qualitative thoroughness for species detection often lack the intensity necessary to monitor vegetation change. Four sampling methods (systematic plot, stratified-random plot, modified Whittaker, and timed meander) in hemlock and red...
Implementing the European Neutron Monitor Service for the ESA SSA Program
NASA Astrophysics Data System (ADS)
Mavromichalaki, H.; Papaioannou, A.; Souvatzoglou, G.; Dimitroulakos, J.; Paschalis, P.; Gerontidou, M.; Sarlanis, Ch.
2013-09-01
Ground level enhancements (GLEs) are observed as significant intensity increases at neutron monitor measurements, followed by an intense solar flare and/or a very energetic coronal mass ejection. Due to their space weather impact it is crucial to establish a real-time operational system that would be in place to issue reliable and timely GLE Alerts. Such a Neutron Monitor Service that will be made available via the Space Weather Portal operated by the European Space Agency (ESA), under the Space Situational Awareness (SSA) Program, is currently under development. The ESA Neutron Monitor Service will provide two products: a web interface providing data from multiple Neutron Monitor stations as well as an upgraded GLE Alert. Both services are now under testing and validation and will probably enter to an operational phase next year. The core of this Neutron Monitor Service is the GLE Alert software, and therefore, the main goal of this research effort is to upgrade the existing GLE Alert software and to minimize the probability of false alarms. The ESA Neutron Monitor Service is building upon the infrastructure made available with the implementation of the High-Resolution Neutron Monitor Database (NMDB). In this work the structure of the ESA Neutron Monitor Service, the core of the novel GLE Alert Service and its validation results will be presented and further discussed.
Jacobson, Herbert Samuel; Tumer, Ural; Karahacioglu, Hamit
1972-01-01
This report reviews progress made during 1968 in the continuing Joint Haden Tetkik ve Arama Enstitusu (MSA)-U. S. Geological Survey (USGS) Mineral Exploration and Training Project, Subproject 2. Subproject 2 is concerned with aeromagnetic interpretation of MTA's aeromagnetic surveys, and ground investigations of selected aeromagnetic anomalies. This report includes new aeromagnetic maps for the Bolu, Canakkale-Karabiga, Demirkoy, and Orhaneli areas and reviews ground investigations in five areas. Activities for each area are sunmarized below: 1. Bolu area: The aeromagnetic map shows two belts of anomalies related to regional magnetite-bearing formations and a group of discrete anomalies, some of which may reflect significant concentrations of magnetite. To date three of these anomalies have been checked on the ground and at one a metamorphic rock containing 14 percent magnetite was observed. 2. Canakkale-Karabiga area: Ground checks were made of six aeromagnetic anomalies. At one locality (Cakirly-Koyu) 6 km south of Nazmara Sea a small magnetite deposit was found. The magnetic anomaly over the area is 150 meters long, and about 3 meters deep in the center of the anomaly exposed massive magnetite boulders. 3. Demirkoy area: The aeromagnetic map shows only one significant anomaly which was checked on the ground and found to be caused by minor magnetite at an intrusive contact. 4. Ezine area: A ground survey of 4.5 sq km area was made where magnetite boulders are locally present on the surface. No significant magnetic anomaly or iron mineralization were found. 5. Orhaneli area: The aeromagnetic map o# the area showed regional magnetic anomaly patterns related to magnetite in mafic intrusives, ultramafic rocks, and mafic flow rocks. In addition 16 localized anomalies were identified. Most of these anomalies were checked on the ground but no significant iron deposits were found. The largest deposit found was a one-meter wide magnetite vein. During the 1969 field season further investigation of anomalies in the Bolu and Orhaneli areas is planned.
Ewertowski, Helen; Tetzlaff, Fabian; Stiel, Stephanie; Schneider, Nils; Jünger, Saskia
2018-01-30
The focus of this project is on improving the provision of primary palliative care (PC) by general practitioners (GPs). While approximately 10-15% of the incurable, seriously ill or dying people will be in need of specialist PC, the vast majority can be adequately treated within generalist care. The strengthening of the GP's role in PC, as well as ensuring close collaboration between specialist PC services and GPs have been identified as top priorities for the improvement of PC in Germany. Despite healthcare policy actions, diverse obstacles still exist to successful implementation of primary PC on a structural, process, and economic level. Therefore, this project aims at addressing barriers and facilitators to primary PC delivery in general practice in Germany. The study follows a three-step approach; first, it aims at systematically analyzing barriers and facilitators to primary PC provision by GPs. Second, based on these outcomes, a tailored intervention package will be developed to enhance the provision of primary PC by GPs. Third, the intervention package will be implemented and evaluated in practice. The expected outcome will be an evidence-based model for successful implementation of primary PC delivery tailored to the German healthcare system, followed by a strategic action plan on how to improve current practice both on a local level and nationally. The first step of the project has been partly completed at the time of writing. The chosen methodologies of four sub-projects within this first step have opened up different advantages and disadvantages for the data collection. In sum of all sub-projects, the different methodologies and target groups contributed valuable information to the systematic analysis of barriers and facilitators to primary PC provision by GPs. The study (BMBF-FK 01 GY 1610) was retrospectively registered at the German Clinical Trials Register (Deutsches Register Klinischer Studien) (Registration N° DRKS00011821 ; date of registration: December 04th 2017) and at the German Register of health care research (Versorgungsforschung Deutschland - Datenbank) (Registration N° VfD_ALLPRAX_16_003817 ; date of registration: March 30th 2017).
Advanced Methods for Aircraft Engine Thrust and Noise Benefits: Nozzle-Inlet Flow Analysis
NASA Technical Reports Server (NTRS)
Morgan, Morris H.; Gilinsky, Mikhail M.
2001-01-01
Three connected sub-projects were conducted under reported project. Partially, these sub-projects are directed to solving the problems conducted by the HU/FM&AL under two other NASA grants. The fundamental idea uniting these projects is to use untraditional 3D corrugated nozzle designs and additional methods for exhaust jet noise reduction without essential thrust lost and even with thrust augmentation. Such additional approaches are: (1) to add some solid, fluid, or gas mass at discrete locations to the main supersonic gas stream to minimize the negative influence of strong shock waves forming in propulsion systems; this mass addition may be accompanied by heat addition to the main stream as a result of the fuel combustion or by cooling of this stream as a result of the liquid mass evaporation and boiling; (2) to use porous or permeable nozzles and additional shells at the nozzle exit for preliminary cooling of exhaust hot jet and pressure compensation for non-design conditions (so-called continuous ejector with small mass flow rate; and (3) to propose and analyze new effective methods fuel injection into flow stream in air-breathing engines. Note that all these problems were formulated based on detailed descriptions of the main experimental facts observed at NASA Glenn Research Center. Basically, the HU/FM&AL Team has been involved in joint research with the purpose of finding theoretical explanations for experimental facts and the creation of the accurate numerical simulation technique and prediction theory for solutions for current problems in propulsion systems solved by NASA and Navy agencies. The research is focused on a wide regime of problems in the propulsion field as well as in experimental testing and theoretical and numerical simulation analysis for advanced aircraft and rocket engines. The F&AL Team uses analytical methods, numerical simulations, and possible experimental tests at the Hampton University campus. We will present some management activity and theoretical numerical simulation results obtained by the FM&AL Team in the reporting period in accordance with the schedule of the work.
High-Performance, Radiation-Hardened Electronics for Space Environments
NASA Technical Reports Server (NTRS)
Keys, Andrew S.; Watson, Michael D.; Frazier, Donald O.; Adams, James H.; Johnson, Michael A.; Kolawa, Elizabeth A.
2007-01-01
The Radiation Hardened Electronics for Space Environments (RHESE) project endeavors to advance the current state-of-the-art in high-performance, radiation-hardened electronics and processors, ensuring successful performance of space systems required to operate within extreme radiation and temperature environments. Because RHESE is a project within the Exploration Technology Development Program (ETDP), RHESE's primary customers will be the human and robotic missions being developed by NASA's Exploration Systems Mission Directorate (ESMD) in partial fulfillment of the Vision for Space Exploration. Benefits are also anticipated for NASA's science missions to planetary and deep-space destinations. As a technology development effort, RHESE provides a broad-scoped, full spectrum of approaches to environmentally harden space electronics, including new materials, advanced design processes, reconfigurable hardware techniques, and software modeling of the radiation environment. The RHESE sub-project tasks are: SelfReconfigurable Electronics for Extreme Environments, Radiation Effects Predictive Modeling, Radiation Hardened Memory, Single Event Effects (SEE) Immune Reconfigurable Field Programmable Gate Array (FPGA) (SIRF), Radiation Hardening by Software, Radiation Hardened High Performance Processors (HPP), Reconfigurable Computing, Low Temperature Tolerant MEMS by Design, and Silicon-Germanium (SiGe) Integrated Electronics for Extreme Environments. These nine sub-project tasks are managed by technical leads as located across five different NASA field centers, including Ames Research Center, Goddard Space Flight Center, the Jet Propulsion Laboratory, Langley Research Center, and Marshall Space Flight Center. The overall RHESE integrated project management responsibility resides with NASA's Marshall Space Flight Center (MSFC). Initial technology development emphasis within RHESE focuses on the hardening of Field Programmable Gate Arrays (FPGA)s and Field Programmable Analog Arrays (FPAA)s for use in reconfigurable architectures. As these component/chip level technologies mature, the RHESE project emphasis shifts to focus on efforts encompassing total processor hardening techniques and board-level electronic reconfiguration techniques featuring spare and interface modularity. This phased approach to distributing emphasis between technology developments provides hardened FPGA/FPAAs for early mission infusion, then migrates to hardened, board-level, high speed processors with associated memory elements and high density storage for the longer duration missions encountered for Lunar Outpost and Mars Exploration occurring later in the Constellation schedule.
Ly, Sovann; Arashiro, Takeshi; Ieng, Vanra; Tsuyuoka, Reiko; Parry, Amy; Horwood, Paul; Heng, Seng; Hamid, Sarah; Vandemaele, Katelijn; Chin, Savuth; Sar, Borann; Arima, Yuzo
2017-01-01
To establish seasonal and alert thresholds and transmission intensity categories for influenza to provide timely triggers for preventive measures or upscaling control measures in Cambodia. Using Cambodia's influenza-like illness (ILI) and laboratory-confirmed influenza surveillance data from 2009 to 2015, three parameters were assessed to monitor influenza activity: the proportion of ILI patients among all outpatients, proportion of ILI samples positive for influenza and the product of the two. With these parameters, four threshold levels (seasonal, moderate, high and alert) were established and transmission intensity was categorized based on a World Health Organization alignment method. Parameters were compared against their respective thresholds. Distinct seasonality was observed using the two parameters that incorporated laboratory data. Thresholds established using the composite parameter, combining syndromic and laboratory data, had the least number of false alarms in declaring season onset and were most useful in monitoring intensity. Unlike in temperate regions, the syndromic parameter was less useful in monitoring influenza activity or for setting thresholds. Influenza thresholds based on appropriate parameters have the potential to provide timely triggers for public health measures in a tropical country where monitoring and assessing influenza activity has been challenging. Based on these findings, the Ministry of Health plans to raise general awareness regarding influenza among the medical community and the general public. Our findings have important implications for countries in the tropics/subtropics and in resource-limited settings, and categorized transmission intensity can be used to assess severity of potential pandemic influenza as well as seasonal influenza.
NASA Astrophysics Data System (ADS)
Wang, Wanshun; Chen, Zhuo; Li, Xiuwen
2018-03-01
The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.
Cheng, Li-Juan; Xu, Zhe-Rong; Zhang, Qin; Wang, Zhao-Di; Wu, Fang-Wei; Yang, Wei-Xia
2016-01-01
The aim was to evaluate the effect of comprehensive intensive therapy on the carotid and femoral arteries of intima-media thickness in patients with type 2 diabetes mellitus after 4-year follow-up. In this prospective 4-year study, patients (N = 210) with newly diagnosed type 2 diabetes received either comprehensive intensive therapy (n = 110) or conventional therapy (n = 100). Blood pressure, blood glucose and lipid levels were monitored every 3-6 months, and carotid and femoral arteries of intima-media thickness were monitored with ultrasonography. For the literature review, various databases were searched until 20 December 2014 for studies that evaluated effects of intensive multi-factorial therapies on comprehensive intensive therapy in type 2 diabetes mellitus patients. The comprehensive intensive therapy group had a smaller rate of carotid intima-media thickness increase than the conventional therapy (control) group (p < 0.05). The carotid intima-media thickness in comprehensive intensive therapy group remained stable while the adjusted rate of carotid intima-media thickness increase was 12.55% in the control group. The femoral intima-media thickness change was also smaller in comprehensive intensive therapy group but the difference over time did not reach significance. The carotid intima-media thickness remained stable in type 2 diabetes mellitus patients who received comprehensive intensive therapy, suggesting that multi-factorial intensive therapies might have potential in reducing macro-vascular events in these patients. © The Author(s) 2015.
NASA Astrophysics Data System (ADS)
Syed Mazlan, S. M. S.; Abdullah, S. R.; Shahidan, S.; Noor, S. R. Mohd
2017-11-01
Concrete durability may be affected by so many factors such as chemical attack and weathering action that reduce the performance and the service life of concrete structures. Low durability Reinforced concrete (RC) can be greatly improved by using Fiber Reinforce Polymer (FRP). FRP is a commonly used composite material for repairing and strengthening RC structures. A review on application of Acoustic Emission (AE) techniques of real time monitoring for various mechanical tests for RC strengthened with FRP involving four-point bending, three-point bending and cyclic loading was carried out and discussed in this paper. Correlations between each AE analyses namely b-value, sentry and intensity analysis on damage characterization also been critically reviewed. From the review, AE monitoring involving RC strengthened with FRP using b-value, sentry and intensity analysis are proven to be successful and efficient method in determining damage characterization. However, application of AE analysis using sentry analysis is still limited compared to b-value and intensity analysis in characterizing damages especially for RC strengthened with FRP specimen.
Monitoring of Solar Radiation Intensity using Wireless Sensor Network for Plant Growing
NASA Astrophysics Data System (ADS)
Siregar, B.; Fadli, F.; Andayani, U.; Harahap, LA; Fahmi, F.
2017-01-01
Abstract— Plant growth is highly depending on the sunlight, if the consumption of sunlight is enough, it will grow well. The plant will be green because of its chlorophyll and it can perform photosynthesis at maximum; but if the plants get less sunlight, it will make the plants be yellowing. Radiation is electromagnetic waves that are good for plants, so-called visible light. In the electromagnetic wave spectrum the best wavelength range from 400-700 nm for the plant. A monitoring of sun intensity is needed in order to obtain sufficient solar radiation consumption and provide notification if there is a high radiation. In this study, several sensors and devices were combined such as photosynthetic solar radiation sensors, GSM / GPRS and waspmote as a main board or a microcontroller. The test was carried out on at least three occasions; the system has a stable radiation in the morning with an average of 505.51 micrometers. IN this study, we have successfully developed a monitoring tools for solar radiation intensity applied on plant growth by using wireless sensor network.
Neonatal non-contact respiratory monitoring based on real-time infrared thermography
2011-01-01
Background Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring of neonatal vital signals based on infrared thermography as a new biomedical engineering application. One signal of clinical interest is the spontaneous respiration rate of the neonate. It will be shown that the respiration rate of neonates can be monitored based on analysis of the anterior naris (nostrils) temperature profile associated with the inspiration and expiration phases successively. Objective The aim of this study is to develop and investigate a new non-contact respiration monitoring modality for neonatal intensive care unit (NICU) using infrared thermography imaging. This development includes subsequent image processing (region of interest (ROI) detection) and optimization. Moreover, it includes further optimization of this non-contact respiration monitoring to be considered as physiological measurement inside NICU wards. Results Continuous wavelet transformation based on Debauches wavelet function was applied to detect the breathing signal within an image stream. Respiration was successfully monitored based on a 0.3°C to 0.5°C temperature difference between the inspiration and expiration phases. Conclusions Although this method has been applied to adults before, this is the first time it was used in a newborn infant population inside the neonatal intensive care unit (NICU). The promising results suggest to include this technology into advanced NICU monitors. PMID:22243660
Igor F. Buksha; Valentina L. Meshkova; Oleg M. Radchenko; Alexander S. Sidorov
1998-01-01
Forests in the Ukraine are affected by environmental pollution, intensive forestry practice, and recreational uses. These factors make them sensitive to impacts of climate change. Since 1989 Ukraine has participated in the International Cooperative Program on Assessment and Monitoring of Air Pollution Effects on Forests (ICP-Forests). A network of monitoring plots has...
Microfabricated Multianalyte Sensor Arrays for Metabolic Monitoring
2007-09-01
Introduction Intensive treatment with the goal of maintaining blood glucose concentrations close to the normal range can prevent or delay...the occurrence of diabetic related complications.1 Diabetic patients, therefore, have to frequently monitor their blood glucose levels by drawing... blood necessary for conventional glucose monitoring. The blood data obtained gives no indication of direction or trend of blood sugar levels. Even the
Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry
NASA Astrophysics Data System (ADS)
Zourabian, Anna; Siegel, Andrew M.; Chance, Britton; Ramanujam, Nirmala; Rode, Martha; Boas, David A.
2000-10-01
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to electronic fetal heart rate monitoring (cardiotocography) because it allows direct assessment of both the fetal oxygen status and fetal tissue perfusion. Here we present the analysis for determining the most optimal wavelength selection for pulse oximetry. The wavelengths we chose as the most optimal are the first in the range of 670 - 720 nm and the second in the range of 825 - 925 nm. Further, we discuss the possible systematic errors during our measurements and their contribution to the obtained saturation results. We present feasibility studies for fetal pulse oximetry, monitored noninvasively through the maternal abdomen. Our preliminary experiments show that the fetal pulse can be discriminated from the maternal pulse and thus, in principle, the fetal arterial oxygen saturation can be obtained. We present the methodology for obtaining these data, and discuss the dependence of our measurements on the fetal position with respect to the optode assembly.
Strier, Karen B; Possamai, Carla B; Tabacow, Fernanda P; Pissinatti, Alcides; Lanna, Andre M; Rodrigues de Melo, Fabiano; Moreira, Leandro; Talebi, Maurício; Breves, Paula; Mendes, Sérgio L; Jerusalinsky, Leandro
2017-01-01
Demographic data are essential to assessments of the status of endangered species. However, establishing an integrated monitoring program to obtain useful data on contemporary and future population trends requires both the identification of priority areas and populations and realistic evaluations of the kinds of data that can be obtained under different monitoring regimes. We analyzed all known populations of a critically endangered primate, the muriqui (genus: Brachyteles) using population size, genetic uniqueness, geographic importance (including potential importance in corridor programs) and implementability scores to define monitoring priorities. Our analyses revealed nine priority populations for the northern muriqui (B. hypoxanthus) and nine for the southern muriqui (B. arachnoides). In addition, we employed knowledge of muriqui developmental and life history characteristics to define the minimum monitoring intensity needed to evaluate demographic trends along a continuum ranging from simple descriptive changes in population size to predictions of population changes derived from individual based life histories. Our study, stimulated by the Brazilian government's National Action Plan for the Conservation of Muriquis, is fundamental to meeting the conservation goals for this genus, and also provides a model for defining priorities and methods for the implementation of integrated demographic monitoring programs for other endangered and critically endangered species of primates.
Improving detection of patient deterioration in the general hospital ward environment.
Vincent, Jean-Louis; Einav, Sharon; Pearse, Rupert; Jaber, Samir; Kranke, Peter; Overdyk, Frank J; Whitaker, David K; Gordo, Federico; Dahan, Albert; Hoeft, Andreas
2018-05-01
: Patient monitoring on low acuity general hospital wards is currently based largely on intermittent observations and measurements of simple variables, such as blood pressure and temperature, by nursing staff. Often several hours can pass between such measurements and patient deterioration can go unnoticed. Moreover, the integration and interpretation of the information gleaned through these measurements remains highly dependent on clinical judgement. More intensive monitoring, which is commonly used in peri-operative and intensive care settings, is more likely to lead to the early identification of patients who are developing complications than is intermittent monitoring. Early identification can trigger appropriate management, thereby reducing the need for higher acuity care, reducing hospital lengths of stay and admission costs and even, at times, improving survival. However, this degree of monitoring has thus far been considered largely inappropriate for general hospital ward settings due to device costs and the need for staff expertise in data interpretation. In this review, we discuss some developing options to improve patient monitoring and thus detection of deterioration in low acuity general hospital wards.
Bakrania, Kishan; Yates, Thomas; Rowlands, Alex V.; Esliger, Dale W.; Bunnewell, Sarah; Sanders, James; Davies, Melanie; Khunti, Kamlesh; Edwardson, Charlotte L.
2016-01-01
Objectives (1) To develop and internally-validate Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) thresholds for separating sedentary behaviours from common light-intensity physical activities using raw acceleration data collected from both hip- and wrist-worn tri-axial accelerometers; and (2) to compare and evaluate the performances between the ENMO and MAD metrics. Methods Thirty-three adults [mean age (standard deviation (SD)) = 27.4 (5.9) years; mean BMI (SD) = 23.9 (3.7) kg/m2; 20 females (60.6%)] wore four accelerometers; an ActiGraph GT3X+ and a GENEActiv on the right hip; and an ActiGraph GT3X+ and a GENEActiv on the non-dominant wrist. Under laboratory-conditions, participants performed 16 different activities (11 sedentary behaviours and 5 light-intensity physical activities) for 5 minutes each. ENMO and MAD were computed from the raw acceleration data, and logistic regression and receiver-operating-characteristic (ROC) analyses were implemented to derive thresholds for activity discrimination. Areas under ROC curves (AUROC) were calculated to summarise performances and thresholds were assessed via executing leave-one-out-cross-validations. Results For both hip and wrist monitor placements, in comparison to the ActiGraph GT3X+ monitors, the ENMO and MAD values derived from the GENEActiv devices were observed to be slightly higher, particularly for the lower-intensity activities. Monitor-specific hip and wrist ENMO and MAD thresholds showed excellent ability for separating sedentary behaviours from motion-based light-intensity physical activities (in general, AUROCs >0.95), with validation indicating robustness. However, poor classification was experienced when attempting to isolate standing still from sedentary behaviours (in general, AUROCs <0.65). The ENMO and MAD metrics tended to perform similarly across activities and accelerometer brands. Conclusions Researchers can utilise these robust monitor-specific hip and wrist ENMO and MAD thresholds, in order to accurately separate sedentary behaviours from common motion-based light-intensity physical activities. However, caution should be taken if isolating sedentary behaviours from standing is of particular interest. PMID:27706241
Bakrania, Kishan; Yates, Thomas; Rowlands, Alex V; Esliger, Dale W; Bunnewell, Sarah; Sanders, James; Davies, Melanie; Khunti, Kamlesh; Edwardson, Charlotte L
2016-01-01
(1) To develop and internally-validate Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) thresholds for separating sedentary behaviours from common light-intensity physical activities using raw acceleration data collected from both hip- and wrist-worn tri-axial accelerometers; and (2) to compare and evaluate the performances between the ENMO and MAD metrics. Thirty-three adults [mean age (standard deviation (SD)) = 27.4 (5.9) years; mean BMI (SD) = 23.9 (3.7) kg/m2; 20 females (60.6%)] wore four accelerometers; an ActiGraph GT3X+ and a GENEActiv on the right hip; and an ActiGraph GT3X+ and a GENEActiv on the non-dominant wrist. Under laboratory-conditions, participants performed 16 different activities (11 sedentary behaviours and 5 light-intensity physical activities) for 5 minutes each. ENMO and MAD were computed from the raw acceleration data, and logistic regression and receiver-operating-characteristic (ROC) analyses were implemented to derive thresholds for activity discrimination. Areas under ROC curves (AUROC) were calculated to summarise performances and thresholds were assessed via executing leave-one-out-cross-validations. For both hip and wrist monitor placements, in comparison to the ActiGraph GT3X+ monitors, the ENMO and MAD values derived from the GENEActiv devices were observed to be slightly higher, particularly for the lower-intensity activities. Monitor-specific hip and wrist ENMO and MAD thresholds showed excellent ability for separating sedentary behaviours from motion-based light-intensity physical activities (in general, AUROCs >0.95), with validation indicating robustness. However, poor classification was experienced when attempting to isolate standing still from sedentary behaviours (in general, AUROCs <0.65). The ENMO and MAD metrics tended to perform similarly across activities and accelerometer brands. Researchers can utilise these robust monitor-specific hip and wrist ENMO and MAD thresholds, in order to accurately separate sedentary behaviours from common motion-based light-intensity physical activities. However, caution should be taken if isolating sedentary behaviours from standing is of particular interest.
Low-cost vibration sensor based on dual fiber Bragg gratings and light intensity measurement.
Gao, Xueqing; Wang, Yongjiao; Yuan, Bo; Yuan, Yinquan; Dai, Yawen; Xu, Gang
2013-09-20
A vibration monitoring system based on light intensity measurement has been constructed, and the designed accelerometer is based on steel cantilever frame and dual fiber Bragg gratings (FBGs). By using numerical simulations for the dual FBGs, the dependence relationship of the area of main lobes on the difference of initial central wavelengths is obtained and the most optimal choice for the initial value and the vibration amplitude of the difference of central wavelengths of two FBGs is suggested. The vibration monitoring experiments are finished, and the measured data are identical to the simulated results.
The CareFlight Stretcher Bridge: a compact mobile intensive care unit.
Wishaw, K J; Munford, B J; Roby, H P
1990-05-01
A mobile intensive care module has been developed for aeromedical transport of the critical care patient. It incorporates monitoring, ventilator, oxygen and suction, and infusion pumps. The device clips to a lightweight stretcher, over the patient at hip to knee level. This system is compatible with nearly all patient transport vehicles and allows monitors to be run from vehicle power. An assessment of the system after more than 500 transports is that it represents a significant advance over systems used previously. The advantages and disadvantages of the system compared with unmounted or vehicle-mounted equipment are discussed.
Using rainfall radar data to improve interpolated maps of dose rate in the Netherlands.
Hiemstra, Paul H; Pebesma, Edzer J; Heuvelink, Gerard B M; Twenhöfel, Chris J W
2010-12-01
The radiation monitoring network in the Netherlands is designed to detect and track increased radiation levels, dose rate more specifically, in 10-minute intervals. The network consists of 153 monitoring stations. Washout of radon progeny by rainfall is the most important cause of natural variations in dose rate. The increase in dose rate at a given time is a function of the amount of progeny decaying, which in turn is a balance between deposition of progeny by rainfall and radioactive decay. The increase in progeny is closely related to average rainfall intensity over the last 2.5h. We included decay of progeny by using weighted averaged rainfall intensity, where the weight decreases back in time. The decrease in weight is related to the half-life of radon progeny. In this paper we show for a rainstorm on the 20th of July 2007 that weighted averaged rainfall intensity estimated from rainfall radar images, collected every 5min, performs much better as a predictor of increases in dose rate than using the non-averaged rainfall intensity. In addition, we show through cross-validation that including weighted averaged rainfall intensity in an interpolated map using universal kriging (UK) does not necessarily lead to a more accurate map. This might be attributed to the high density of monitoring stations in comparison to the spatial extent of a typical rain event. Reducing the network density improved the accuracy of the map when universal kriging was used instead of ordinary kriging (no trend). Consequently, in a less dense network the positive influence of including a trend is likely to increase. Furthermore, we suspect that UK better reproduces the sharp boundaries present in rainfall maps, but that the lack of short-distance monitoring station pairs prevents cross-validation from revealing this effect. Copyright © 2010 Elsevier B.V. All rights reserved.
Review and assessment of the database and numerical modeling for turbine heat transfer
NASA Technical Reports Server (NTRS)
Gladden, H. J.; Simoneau, R. J.
1989-01-01
The objectives of the NASA Hot Section Technology (HOST) Turbine Heat Transfer subproject were to obtain a better understanding of the physics of the aerothermodynamic phenomena and to assess and improve the analytical methods used to predict the flow and heat transfer in high-temperature gas turbines. At the time the HOST project was initiated, an across-the-board improvement in turbine design technology was needed. A building-block approach was utilized and the research ranged from the study of fundamental phenomena and modeling to experiments in simulated real engine environments. Experimental research accounted for approximately 75 percent of the funding while the analytical efforts were approximately 25 percent. A healthy government/industry/university partnership, with industry providing almost half of the research, was created to advance the turbine heat transfer design technology base.
2013-01-01
Introduction Many intensive care unit (ICU) patients describe pain and other adverse feelings that may impact long-term psychological morbidity. Sympathetically mediated palmar skin conductance variability is related to emotionally induced perspiration and correlates with pain levels in the perioperative setting but has not been studied in ICU patients. Methods Twenty non-intubated and 20 intubated general ICU patients were included in this observational study. Patients were monitored with the MED-STORM Pain Monitoring System®. The number of skin conductance fluctuations per second (NSCF) was measured in parallel with bedside observation during one hour of intensive care, including rest, procedures and patient-staff interactions. Arousal-agitation level was monitored with the motor activity assessment scale (MAAS). Pain was monitored with the numeric rating scale (0 to 10) in patients able to communicate or by observation in patients unable to communicate. Results In non-intubated patients, NSCF increased with increasing stimulation/pain but also with higher MAAS (P = 0.002). An interaction effect was found, with increased NSCF response to stimulation/pain with increasing MAAS (P < 0.001). In intubated patients, NSCF increased significantly with increasing stimulation/pain (P < 0.001). In contrast to non-intubated patients, no difference in NSCF between MAAS levels was found for any given degree of stimulation in intubated patients. Conclusions In critically ill patients, NSCF may be more useful evaluating emotional distress rather than pain alone. It needs to be assessed whether NSCF monitoring is clinically useful and whether controlling emotional distress with the aid of such monitoring may impact on patient care and outcomes. PMID:23510014
NASA Astrophysics Data System (ADS)
Papailiou, M.; Mavromichalaki, H.; Vassilaki, A.; Kelesidis, K. M.; Mertzanos, G. A.; Petropoulos, B.
2009-02-01
There is an increasing amount of evidence linking biological effects to solar and geomagnetic disturbances. A series of studies is published referring to the changes in human physiological responses at different levels of geomagnetic activity. In this study, the possible relation between the daily variations of cosmic ray intensity, measured by the Neutron Monitor at the Cosmic Ray Station of the University of Athens (http://cosray.phys.uoa.gr) and the average daily and hourly heart rate variations of persons, with no symptoms or hospital admission, monitored by Holter electrocardiogram, is considered. This work refers to a group of persons admitted to the cardiological clinic of the KAT Hospital in Athens during the time period from 4th to 24th December 2006 that is characterized by extreme solar and geomagnetic activity. A series of Forbush decreases started on 6th December and lasted until the end of the month and a great solar proton event causing a Ground Level Enhancement (GLE) of the cosmic ray intensity on 13th December occurred. A sudden decrease of the cosmic ray intensity on 15th December, when a geomagnetic storm was registered, was also recorded in Athens Neutron Monitor station (cut-off rigidity 8.53 GV) with amplitude of 4%. It is noticed that during geomagnetically quiet days the heart rate and the cosmic ray intensity variations are positively correlated. When intense cosmic ray variations, like Forbush decreases and relativistic proton events produced by strong solar phenomena occur, cosmic ray intensity and heart rate get minimum values and their variations, also, coincide. During these events the correlation coefficient of these two parameters changes and follows the behavior of the cosmic ray intensity variations. This is only a small part of an extended investigation, which has begun using data from the year 2002 and is still in progress.
Rodbard, David; Zanella, Maria Teresa
2011-01-01
Abstract Background We evaluated intensive intervention in poorly controlled patients with type 2 diabetes mellitus involving weekly clinic visits and adjustment of therapy with analysis of three seven-point glucose profiles and intervention from an interdisciplinary staff. Methods Sixty-three patients were randomized to an intensive treatment group that obtained self-monitoring of blood glucose (SMBG) profiles (six or seven values per day, 3 days/week) and were seen in the clinic at Weeks 1–6 and 12. SMBG results were downloaded, analyzed using Accu-Chek® 360° software (Roche Diagnostics, Indianapolis, IN), and used to adjust therapy. Control group subjects obtained glucose profiles and had clinic visits only at Weeks 0, 6, and 12. Results There were highly statistically significant improvements in the intensive treatment group compared with the control group between Weeks 0 and 6 with greater reductions in weekly mean glycemia (WMG) (−76.7±8.9 mg/dL vs. −20.5±8.1 mg/dL), glycemic variability (SD) (−16.3±3.1 mg/dL vs. −5.0±3.1 mg/dL), and glycated hemoglobin (−1.82±0.16% vs. −0.66±0.22%) without significant changes in frequency of hypoglycemia or weight. Improvements were sustained in the intensive treatment group through Week 12. A minimal but statistically significant degree of improvement was seen in the control group at Week 12. Conclusions This short-term pilot study of an intensive monitoring, educational, and pharmacological interventions program resulted in dramatic improvement of glycemic control within 6 weeks, and these effects are sustained through Week 12. SMBG glucose profiles, calculation of WMG and SD, and graphical displays of glucose data can improve the effectiveness of adjustment of therapy at weekly clinic visits when combined with intensive support from a multidisciplinary team. PMID:21751888
Land use intensity trajectories on Amazonian pastures derived from Landsat time series
NASA Astrophysics Data System (ADS)
Rufin, Philippe; Müller, Hannes; Pflugmacher, Dirk; Hostert, Patrick
2015-09-01
Monitoring changes in land use intensity of grazing systems in the Amazon is an important prerequisite to study the complex political and socio-economic forces driving Amazonian deforestation. Remote sensing offers the potential to map pasture vegetation over large areas, but mapping pasture conditions consistently through time is not a trivial task because of seasonal changes associated with phenology and data gaps from clouds and cloud shadows. In this study, we tested spectral-temporal metrics derived from intra-annual Landsat time series to distinguish between grass-dominated and woody pastures. The abundance of woody vegetation on pastures is an indicator for management intensity, since the duration and intensity of land use steer secondary succession rates, apart from climate and soil conditions. We used the developed Landsat-based metrics to analyze pasture intensity trajectories between 1985 and 2012 in Novo Progresso, Brazil, finding that woody vegetation cover generally decreased after four to ten years of grazing activity. Pastures established in the 80s and early 90s showed a higher fraction of woody vegetation during their initial land use history than pastures established in the early 2000s. Historic intensity trajectories suggested a trend towards more intensive land use in the last decade, which aligns well with regional environmental policies and market dynamics. This study demonstrates the potential of dense Landsat time series to monitor land-use intensification on Amazonian pastures.
Optically active biological particle distinguishing apparatus
Salzman, Gary C.; Kupperman, Robert H.
1989-01-01
The disclosure is directed to organic particle sorting and identification. High frequency pulses of circularly polarized light, alternating between left and right, intersect a fast moving stream of organic particles. Circular intensity differential scattering and linear intensity differential scattering are monitored to uniquely identify a variety of organic particles.
SLIGHTLY IRRADIATED FUEL (SIF) INTERIM DISPOSITION PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
NORTON SH
2010-02-23
CH2M HILL Plateau Remediation Company (CH2M HILL PRC) is proud to submit the Slightly Irradiated Fuel (SIF) Interim Disposition Project for consideration by the Project Management Institute as Project of the Year for 2010. The SIF Project was a set of six interrelated sub-projects that delivered unique stand-alone outcomes, which, when integrated, provided a comprehensive and compliant system for storing high risk special nuclear materials. The scope of the six sub-projects included the design, construction, testing, and turnover of the facilities and equipment, which would provide safe, secure, and compliant Special Nuclear Material (SNM) storage capabilities for the SIF material.more » The project encompassed a broad range of activities, including the following: Five buildings/structures removed, relocated, or built; Two buildings renovated; Structural barriers, fencing, and heavy gates installed; New roadways and parking lots built; Multiple detection and assessment systems installed; New and expanded communication systems developed; Multimedia recording devices added; and A new control room to monitor all materials and systems built. Project challenges were numerous and included the following: An aggressive 17-month schedule to support the high-profile Plutonium Finishing Plant (PFP) decommissioning; Company/contractor changeovers that affected each and every project team member; Project requirements that continually evolved during design and construction due to the performance- and outcome-based nature ofthe security objectives; and Restrictions imposed on all communications due to the sensitive nature of the projects In spite of the significant challenges, the project was delivered on schedule and $2 million under budget, which became a special source of pride that bonded the team. For years, the SIF had been stored at the central Hanford PFP. Because of the weapons-grade piutonium produced and stored there, the PFP had some of the tightest security on the Hanford nuclear reservation. Workers had to pass through metal detectors when they arrived at the plant and materials leaving the plant had to be scanned for security reasons. Whereas other high-security nuclear materials were shipped from the PFP to Savannah River, S.C. as part ofa Department of Energy (DOE) program to consolidate weapons-grade plutonium, it was determined that the SIF should remain onsite pending disposition to a national repository. Nevertheless, the SIF still requires a high level of security that the PFP complex has always provided. With the 60-year PFP mission of producing and storing plutonium concluded, the environmental cleanup plans for Hanford call for the demolition of the 63-building PFP complex. Consequently, if the SIF remained at PFP it not only would have interfered with the environmental cleanup plans, but would have required $100 million in facility upgrades to meet increased national security requirements imposed after the 9/11 terrorist attacks. A new smaller and more cost-effective area was needed to store this material, which led to the SIF Project. Once the SIF project was successfully completed and the SIF was safely removed from PFP, the existing Protected Area at PFP could be removed, and demolition could proceed more quickly without being encumbered by restrictive security requirements that an active Protected Area requires. The lightened PFP security level brought by safely removing and storing the SIF would also yield lowered costs for deactivation and demolition, as well as reduce overall life-cycle costs.« less
Time-lapse monitoring of soil water content using electromagnetic conductivity imaging
USDA-ARS?s Scientific Manuscript database
The volumetric soil water content (VWC) is fundamental to agriculture. Unfortunately, the universally accepted thermogravimetric method is labour intensive and time-consuming to use for field-scale monitoring. Electromagnetic (EM) induction instruments have proven to be useful in mapping the spatio-...
de Bruin, Jeroen S; Zeckl, Julia; Adlassnig, Katharina; Blacky, Alexander; Koller, Walter; Rappelsberger, Andrea; Adlassnig, Klaus-Peter
2017-01-01
The creation of clinical decision support systems has received a strong impulse over the last years, but their integration into a clinical routine has lagged behind, partly due to a lack of interoperability and trust by physicians. We report on the implementation of a clinical foundation framework in Arden Syntax, comprising knowledge units for (a) preprocessing raw clinical data, (b) the determination of single clinical concepts, and (c) more complex medical knowledge, which can be modeled through the composition and configuration of knowledge units in this framework. Thus, it can be tailored to clinical institutions or patients' caregivers. In the present version, we integrated knowledge units for several infection-related clinical concepts into the framework and developed a clinical event monitoring system over the framework that employs three different scenarios for monitoring clinical signs of bloodstream infection. The clinical event monitoring system was tested using data from intensive care units at Vienna General Hospital, Austria.
Ratiometric spectral imaging for fast tumor detection and chemotherapy monitoring in vivo
Hwang, Jae Youn; Gross, Zeev; Gray, Harry B.; Medina-Kauwe, Lali K.; Farkas, Daniel L.
2011-01-01
We report a novel in vivo spectral imaging approach to cancer detection and chemotherapy assessment. We describe and characterize a ratiometric spectral imaging and analysis method and evaluate its performance for tumor detection and delineation by quantitatively monitoring the specific accumulation of targeted gallium corrole (HerGa) into HER2-positive (HER2 +) breast tumors. HerGa temporal accumulation in nude mice bearing HER2 + breast tumors was monitored comparatively by a. this new ratiometric imaging and analysis method; b. established (reflectance and fluorescence) spectral imaging; c. more commonly used fluorescence intensity imaging. We also tested the feasibility of HerGa imaging in vivo using the ratiometric spectral imaging method for tumor detection and delineation. Our results show that the new method not only provides better quantitative information than typical spectral imaging, but also better specificity than standard fluorescence intensity imaging, thus allowing enhanced in vivo outlining of tumors and dynamic, quantitative monitoring of targeted chemotherapy agent accumulation into them. PMID:21721808
Carl, M; Alms, A; Braun, J; Dongas, A; Erb, J; Goetz, A; Goepfert, M; Gogarten, W; Grosse, J; Heller, A R; Heringlake, M; Kastrup, M; Kroener, A; Loer, S A; Marggraf, G; Markewitz, A; Reuter, D; Schmitt, D V; Schirmer, U; Wiesenack, C; Zwissler, B; Spies, C
2010-06-15
Hemodynamic monitoring and adequate volume-therapy, as well as the treatment with positive inotropic drugs and vasopressors are the basic principles of the postoperative intensive care treatment of patient after cardiothoracic surgery. The goal of these S3 guidelines is to evaluate the recommendations in regard to evidence based medicine and to define therapy goals for monitoring and therapy. In context with the clinical situation the evaluation of the different hemodynamic parameters allows the development of a therapeutic concept and the definition of goal criteria to evaluate the effect of treatment. Up to now there are only guidelines for subareas of postoperative treatment of cardiothoracic surgical patients, like the use of a pulmonary artery catheter or the transesophageal echocardiography. The German Society for Thoracic and Cardiovascular Surgery (Deutsche Gesellschaft für Thorax-, Herz- und Gefässchirurgie, DGTHG) and the German Society for Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin, DGAI) made an approach to ensure and improve the quality of the postoperative intensive care medicine after cardiothoracic surgery by the development of S3 consensus-based treatment guidelines. Goal of this guideline is to assess the available monitoring methods with regard to indication, procedures, predication, limits, contraindications and risks for use. The differentiated therapy of volume-replacement, positive inotropic support and vasoactive drugs, the therapy with vasodilatators, inodilatators and calcium sensitizers and the use of intra-aortic balloon pumps will also be addressed. The guideline has been developed following the recommendations for the development of guidelines by the Association of the Scientific Medical Societies in Germany (AWMF). The presented key messages of the guidelines were approved after two consensus meetings under the moderation of the Association of the Scientific Medical Societies in Germany (AWMF).
Measuring the Impact of AGN Outflows via Intensive UV and X-ray Monitoring Campaigns
NASA Astrophysics Data System (ADS)
Kriss, Gerard
2015-08-01
Observations of AGN outflows have progressed from the era of single-object surveys to intensive monitoring campaigns spanning weeks to months. The combination of multiple observations, improved temporal coverage, multi-wavelength monitoring in both the X-ray and UV bands, and the baseline of prior historical observations has enabled determinations of the locations, mass flux, and kinetic luminosities of the outflowing absorbing gas in several AGN, notably Mrk 509, NGC 5548, Mrk 335, and NGC 985. Another intensive campaign is planned for 2015-2016 on NGC 7469. In all cases, the mass flux and kinetic energy is dominated by the higher-ionization X-ray absorbing gas. But the higher-resolution UV observations give a kinematically resolved picture of the overall outflow. In most cases, the outflowing gas is located at parsec to kpc scales, with insufficient kinetic luminosity to have an evolutionary impact on the host galaxy. Typically, the kinetic luminosity is less than a percent of the Eddington luminosity. In some cases, transient, broad UV absorption troughs have appeared (e.g., Mrk 335 and NGC 5548), with variability timescales suggesting locations near the broad-line region of the AGN. Yet these higher-velocity outflows also have low-impact kinetic luminosities. In the best-studied case of NGC 5548, the strength of the broad UV absorption lines varies with the degree of soft X-ray obscuration first revealed by XMM-Newton spectra. The lower-ionization, narrow associated absorption lines in the UV spectrum of NGC 5548 that appeared concurrently with the soft X-ray obscuration vary in response to the changing UV flux on a daily basis. The intensive monitoring allows us to fit time-dependent photoionization models to the UV-absorbing gas, allowing precise determinations of the locations, mass flux, and kinetic luminosities of the absorbers.
NASA Astrophysics Data System (ADS)
Antonelli, M.; Di Fraia, M.; Tallaire, A.; Achard, J.; Carrato, S.; Menk, R. H.; Cautero, G.; Giuressi, D.; Jark, W. H.; Biasiol, G.; Ganbold, T.; Oliver, K.; Callegari, C.; Coreno, M.; De Sio, A.; Pace, E.
2012-10-01
New generation Synchrotron Radiation (SR) sources and Free Electron Lasers (FEL) require novel concepts of beam diagnostics to keep photon beams under surveillance, asking for simultaneous position and intensity monitoring. To deal with high power load and short time pulses provided by these sources, novel materials and methods are needed for the next generation BPMs. Diamond is a promising material for the production of semitransparent in situ X-ray BPMs withstanding the high dose rates of SR rings and high energy FELs. We report on the development of freestanding, single crystal CVD diamond detectors. Performances in both low and radio frequency SR beam monitoring are presented. For the former, sensitivity deviation was found to be approximately 2%; a 0.05% relative precision in the intensity measurements and a 0.1-μm precision in the position encoding have been estimated. For the latter, single-shot characterizations revealed sub-nanosecond rise-times and spatial precisions below 6 μm, which allowed bunch-by-bunch monitoring in multi-bunch operation. Preliminary measurements at the Fermi FEL have been performed with this detector, extracting quantitative intensity and position information for FEL pulses (~ 100 fs, energy 12 ÷ 60 eV), with a long-term spatial precision of about 85 μm results on FEL radiation damages are also reported. Due to their direct, low-energy band gap, InGaAs quantum well devices too may be used as fast detectors for photons ranging from visible to X-ray. Results are reported which show the capability of a novel InGaAs/InAlAs device to detect intensity and position of 100-fs-wide laser pulses.
Gap and stripline combined monitor
Yin, Y.
1984-02-16
A combined gap and stripline monitor device for measuring the intensity and position of a charged particle beam bunch in a beam pipe of a synchrotron radiation facility. The monitor has first and second beam pipe portions with an axial gap therebetween. An outer pipe cooperates with the first beam pipe portion to form a gap enclosure, while inner strips cooperate with the first beam pipe portion to form a stripline monitor, with the stripline length being the same as the gap enclosure length.
Gap and stripline combined monitor
Yin, Y.
1986-08-19
A combined gap and stripline monitor device for measuring the intensity and position of a charged particle beam bunch in a beam pipe of a synchrotron radiation facility is disclosed. The monitor has first and second beam pipe portions with an axial gap therebetween. An outer pipe cooperates with the first beam pipe portion to form a gap enclosure, while inner strips cooperate with the first beam pipe portion to form a stripline monitor, with the stripline length being the same as the gap enclosure length. 4 figs.
Public access management as an adaptive wildlife management tool
Ouren, Douglas S.; Watts, Raymond D.
2005-01-01
One key issue in the Black Mesa – Black Canyon area is the interaction between motorized vehicles and. The working hypothesis for this study is that early season elk movement onto private lands and the National Park is precipitated by increased use of Off Highway Vehicles (OHV’s). Data on intensity of motorized use is extremely limited. In this study, we monitor intensity of motorized vehicle and trail use on elk movements and habitat usage and analyze interactions. If management agencies decide to alter accessibility, we will monitor wildlife responses to changes in the human-use regime. This provides a unique opportunity for adaptive management experimentation based on coordinated research and monitoring. The products from this project will provide natural resource managers across the nation with tools and information to better meet these resource challenges.
NASA Astrophysics Data System (ADS)
Oyaga Landa, Francisco Javier; Ronda Penacoba, Silvia; Deán-Ben, Xosé Luís.; Montero de Espinosa, Francisco; Razansky, Daniel
2018-02-01
Medium intensity focused ultrasound (MIFU) holds promise in important clinical applications. Generally, the aim in MIFU is to stimulate physiological mechanisms that reinforce healing responses, avoiding reaching temperatures that can cause permanent tissue damage. The outcome of interventions is then strongly affected by the temperature distribution in the treated region, and accurate monitoring represents a significant clinical need. In this work, we showcase the capacities of 4D optoacoustic imaging to monitor tissue heating during MIFU. The proposed method allows localizing the ultrasound focus, estimating the peak temperature and measuring the size of the heat-affected volume. Calibration experiments in a tissue-mimicking phantom demonstrate that the optoacoustically-estimated temperature accurately matches thermocouple readings. The good performance of the suggested approach in real tissues is further showcased in experiments with bovine muscle samples.
Johnsson, P.A.; Reddy, M.M.
1990-01-01
This report describes a continuous wet-only precipitation monitor designed by the U.S. Geological Survey to record variations in rainfall temperature, pH, and specific conductance at 1-min intervals over the course of storms. Initial sampling in the Adirondack Mountains showed that rainfall acidity varied over the course of summer storms, with low initial pH values increasing as storm intensity increased.This report describes a continuous wet-only precipitation monitor designed by the U.S. Geological Survey to record variations in rainfall temperature, pH, and specific conductance at 1-min intervals over the course of storms. Initial sampling in the Adirondack Mountains showed that rainfall acidity varied over the course of summer storms, with low initial pH values increasing as storm intensity increased.
Obtaining Reliable Estimates of Ambulatory Physical Activity in People with Parkinson's Disease.
Paul, Serene S; Ellis, Terry D; Dibble, Leland E; Earhart, Gammon M; Ford, Matthew P; Foreman, K Bo; Cavanaugh, James T
2016-05-05
We determined the number of days required, and whether to include weekdays and/or weekends, to obtain reliable measures of ambulatory physical activity in people with Parkinson's disease (PD). Ninety-two persons with PD wore a step activity monitor for seven days. The number of days required to obtain a reliable estimate of daily activity was determined from the mean intraclass correlation (ICC2,1) for all possible combinations of 1-6 consecutive days of monitoring. Two days of monitoring were sufficient to obtain reliable daily activity estimates (ICC2,1 > 0.9). Amount (p = 0.03) but not intensity (p = 0.13) of ambulatory activity was greater on weekdays than weekends. Activity prescription based on amount rather than intensity may be more appropriate for people with PD.
Yang, Yun
2007-02-01
In order to investigate the feasibility of serum creatine kinase (CK) and blood urea nitrogen (BUN) in monitoring pre-competition training of badminton athletes, the pre-competition training load of 20 badminton athletes was studied, and serum CK and BUN were determined before, immediate and next morning after training. The results showed that after intensive training for one week, serum CK levels were significantly increased by 57.53 mmol/L (P<0.05). After regulation of the training intensity, average serum CK levels were increased by 21.79 mmol/L (P<0.05). BUN contents were increased by 0.83 mmol/L on average with the difference being not significant (P>0.05). After intermittent training, there was significant difference in the average increased levels of serum CK in athletes (P<0.05). There was significant difference before and after regulation of training (P<0.05). The increased levels of BUN were 0.78 mmol/L without significant difference (P>0.05). It was concluded that serum CK was one of the biochemical indicators monitoring the training load sensitivity of badminton athletes, but BUN was of little value in monitoring the training load. Both serum CK and BUN recovered slowly after one-week intensive training and intermittent training, suggesting the metabolic mechanism of human body in training needs further study.
NASA Astrophysics Data System (ADS)
Antonelli, M.; Di Fraia, M.; Carrato, S.; Cautero, G.; Menk, R. H.; Jark, W. H.; Ganbold, T.; Biasiol, G.; Callegari, C.; Coreno, M.; De Sio, A.; Pace, E.
2013-12-01
Simultaneous photon-beam position and intensity monitoring is becoming of increasing importance for new-generation synchrotron radiation sources and free-electron lasers (FEL). Thus, novel concepts of beam diagnostics are required in order to keep such beams under control. From this perspective diamond is a promising material for the production of semitransparent in situ photon beam monitors, which can withstand the high dose rates occurring in such radiation facilities. Here, we report on the development of freestanding, single-crystal chemical-vapor-deposited diamond detectors with segmented electrodes. Due to their direct, low-energy band gap, InGaAs quantum well devices operated at room temperature may also be used as fast detectors for photons ranging from visible to X-ray. These features are valuable in low-energy and time-resolved FEL applications. In particular, a novel segmented InGaAs/InAlAs device has been developed and will be discussed. Dedicated measurements carried out on both these devices at the Elettra Synchrotron show their capability to monitor the position and the intensity of the photon beam with bunch-by-bunch temporal performances. Furthermore, preliminary tests have been performed on diamond detectors at the Fermi FEL, extracting quantitative intensity and position information for 100-fs-wide FEL pulses with a photon energy of 28.8 eV.
An X-ray beam position monitor based on the photoluminescence of helium gas
NASA Astrophysics Data System (ADS)
Revesz, Peter; White, Jeffrey A.
2005-03-01
A new method for white beam position monitoring for both bend magnet and wiggler synchrotron X-ray radiation has been developed. This method utilizes visible light luminescence generated as a result of ionization by the intense X-ray flux. In video beam position monitors (VBPMs), the luminescence of helium gas at atmospheric pressure is observed through a view port using a CCD camera next to the beam line. The beam position, profile, integrated intensity and FWHM are calculated from the distribution of luminescence intensity in each captured image by custom software. Misalignment of upstream apertures changes the image profile making VBPMs helpful for initial alignment of upstream beam line components. VBPMs can thus provide more information about the X-ray beam than most beam position monitors (BPMs). A beam position calibration procedure, employing a tilted plane-parallel glass plate placed in front of the camera lens, has also been developed. The accuracy of the VBPM system was measured during a bench-top experiment to be better than 1 μm. The He-luminescence-based VBPM system has been operative on three CHESS beam lines (F hard-bend and wiggler, A-line wiggler and G-line wiggler) for about a year. The beam positions are converted to analog voltages and used as feedback signals for beam stabilization. In our paper we discuss details of VBPM construction and describe further results of its performance.
Gregory McCarty; Megan Lang
2016-01-01
Intensive water quality monitoring of agricultural watersheds can provide important information on the effects of land cover and effectiveness of conservation practices designed to mitigate water quality concerns associated with agricultural production.
Dsouza, Roshan; Subhash, Hrebesh; Neuhaus, Kai; Kantamneni, Ramakrishna; McNamara, Paul M; Hogan, Josh; Wilson, Carol; Leahy, Martin
2016-01-01
Monitoring the curing kinetics of light-activated resin is a key area of research. These resins are used in restorative applications and particularly in dental applications. They can undergo volumetric shrinkage due to poor control of the depth dependent curing process, modulated by the intensity and duration of the curing light source. This often results in the formation of marginal gaps, causing pain and damage to the restoration site. In this study, we demonstrate the capabilities of a correlation method applied using a multiple references optical coherence tomography (MR-OCT) architecture to monitor the curing of the resin. A MR-OCT system is used in this study to monitor the curing of the resin. The system operates at the center wavelength of 1310 nm with an A-scan rate of 1200 A-scans per second. The axial and lateral resolution of the system is ∼13 μm and ∼27 μm. The method to determine the intensity correlation between adjacent B-frames is based on the Pearson correlation coefficient for a region of interest. Calculating the correlation coefficient for multiple B-frames related to the first B-frame at regular spaced time points, shows for a noncured resin a reduction of the correlation coefficient over time due to Brownian motion. The time constant of the reduction of the correlation value is a measure for the progress of the polymerization during LED light irradiation of the resin. The proposed approach is potentially a low-cost, powerful and unique optical imaging modality for measuring the curing behavior of dental resin and other resins, coatings, and adhesives in medical and industrial applications. To demonstrate the proposed method to monitor the curing process, a light-activated resin composite from GRADIA DIRECT ANTERIOR (GC Corporation, Japan) is studied. The curing time of resin was measured and monitored as a function of depth. The correlation coefficient method is highly sensitive to Brownian motion. The process of curing results in a change in intensity as measured by the MR-OCT signal and hence can be monitored using this method. These results show that MR-OCT has the potential to measure the curing time and monitor the curing process as a function of depth. Moreover, MR-OCT as a product has potential to be compact, low-cost and to fit into a smartphone. Using such a device for monitoring the curing of the resin will be suitable for dentists in stationary and mobile clinical settings. © 2015 Wiley Periodicals, Inc.
[Structure and functional organization of integrated cardiac intensive care].
Scherillo, Marino; Miceli, Domenico; Tubaro, Marco; Guiducci, Umberto
2007-05-01
The early invasive strategy for the treatment of acute coronary syndromes and the increasing number of older and sicker patients requiring prolonged and more complex intensive care have induced many changes in the function of the intensive care units. These changes include the statement that specially trained cardiologists and cardiac nurses who can manage patients with acute cardiac conditions should staff the intensive care units. This document indicates the structure of the units and specific recommendations for the number of beds, monitoring system, respirators, pacemaker/defibrillators and additional equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallegos, E.J.; Bott, G.
1994-12-31
A systematic study was made of the affect of source temperature 200{degrees}C-350{degrees}C on metastable intensities in MRM (Metastable Reaction Monitoring) experiments with biological marker molecules in petroleum fractions. A similar study was made on the affect on metastable intensity with the presence of a collision gas in the FFR (First Field-free Region) of a double focusing mass spectrometer.
Dual-Modulation, Dual-Wavelength, Optical Polarimetry System for Glucose Monitoring
2016-08-26
dual-wavelength, optical polarimetry system for glucose monitoring 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S) 5d...JBO.21.8.087001] 14. ABSTRACT A dual modulation optical polarimetry system utilizing both laser intensity and polarization modulation was designed...varying birefringence, which is one of the major limitations to the realization of polarimetry for glucose monitoring in the eye. The high-speed less
Hou, Gary Y.; Marquet, Fabrice; Wang, Shutao; Apostolakis, Iason-Zacharias; Konofagou, Elisa E.
2015-01-01
Harmonic Motion Imaging for Focused Ultrasound (HMIFU) is a recently developed High-Intensity Focused Ultrasound (HIFU) treatment monitoring method that utilizes an amplitude-modulated therapeutic ultrasound beam to induce an oscillatory radiation force at the HIFU focus and estimates the focal tissue displacement to monitor the HIFU thermal treatment. In this study, the performance of HMIFU under acoustic, thermal and mechanical effects were investigated. The performance of HMIFU was assessed in ex vivo canine liver specimens (n=13) under slow denaturation or boiling regimes. Passive Cavitation Detector (PCD) was used to assess the acoustic cavitation activity while a bare-wire thermocouple was used to monitor the focal temperature change. During lesioning with slow denaturation, high quality displacements (correlation coefficient above 0.97) were observed under minimum cavitation noise, indicating tissue the initial-softening-then-stiffening property change. During HIFU with boiling, HMIFU monitored a consistent change in lesion-to-background displacement contrast (0.46±0.37) despite the presence of strong cavitation noise due to boiling during lesion formation. Therefore, HMIFU effectively monitored softening-then-stiffening during lesioning under slow denaturation, and detected lesioning under boiling with a distinct change in displacement contrast under boiling in the presence of cavitation. In conclusion, HMIFU was shown effective in HIFU monitoring and lesioning identification without being significantly affected by cavitation noise. PMID:26168177
Lakes provide ecosystem services such as recreation, clean water, aesthetics, wildlife habitat, and nutrient attenuation. While numerous methods exist to monitor these services (e.g. visitor counts, opinion surveys, water quality monitoring, etc.) they are labor intensive to col...
Image interpreter tool: An ArcGIS tool for estimating vegetation cover from high-resolution imagery
USDA-ARS?s Scientific Manuscript database
Land managers need increased temporal and spatial resolution of rangeland assessment and monitoring data. However, with flat or declining land management and monitoring agency budgets, such increases in sampling intensity are unlikely unless new methods can be developed that capture data of key rang...
Luna, Jorge M; Yip, Natalie; Pivovarov, Rimma; Vawdrey, David K
2016-08-01
Clinical teams in acute inpatient settings can greatly benefit from automated charting technologies that continuously monitor patient vital status. NewYork-Presbyterian has designed and developed a real-time patient monitoring system that integrates vital signs sensors, networking, and electronic health records, to allow for automatic charting of patient status. We evaluate the representativeness (a combination of agreement, safety and timing) of a core vital sign across nursing intensity care protocols for preliminary feasibility assessment. Our findings suggest an automated way of summarizing heart rate provides representation of true heart rate status and can facilitate alternatives approaches to burdensome manual nurse charting of physiological parameters.
On the solar cycle variation in the barometer coefficients of high latitude neutron monitors
NASA Technical Reports Server (NTRS)
Kusunose, M.; Ogita, N.
1985-01-01
Evaluation of barometer coefficients of neutron monitors located at high latitudes has been performed by using the results of the spherical harmonic analysis based on the records from around twenty stations for twelve years from January 1966 to December 1977. The average of data at eight stations, where continuous records are available for twelve years, show that the absolute value of barometer coefficient is in positive correlation with the cosmic ray neutron intensity. The variation rate of the barometer coefficient to the cosmic ray neutron intensity is influenced by the changes in the cutoff rigidity and in the primary spectrum.
NASA Astrophysics Data System (ADS)
2012-12-01
The paper presents factors determining dust explosion hazards occurring in underground hard coal mines. The authors described the mechanism of transport and deposition of dust in mines entries and previous research on this topic. The paper presents a method of determination of depositing dust distribution during mining and presents the way to use it to assess coal dust explosion risk. The presented method of calculating the intensity of coal dust deposition is based on continuous monitoring of coal dust concentrations with use of optical sensors. Mathematical model of the distribution of the average coal dust concentration was created. Presented method allows to calculate the intensity of coal dust deposition in a continuous manner. Additionally, the authors presented the PŁ-2 stationary optical dust sampler, used in the study, connected to the monitoring system in the mine. The article features the results of studies conducted in the return air courses of the active longwalls, and the results of calculations of dust deposition intensity carried out with the use of the presented method.
Unusual Cosmic Ray Variations During the Forbush Decreases of June 2015
NASA Astrophysics Data System (ADS)
Samara, E.; Smponias, A.; Lytrosyngounis, I.; Lingri, D.; Mavromichalaki, H.; Sgouropoulos, C.
2018-04-01
Although the current Solar Cycle 24 is characterized by low solar activity, an intense geomagnetic storm (G4) was recorded in June 2015. It was a complex phenomenon that began on 22 June 2015 as the result of intense solar activity, accompanied by several flares and coronal mass ejections that interacted with the Earth's magnetic field. A Forbush decrease was also recorded at the neutron monitors of the worldwide network, with an amplitude of 8.4%, and in its recovery phase, a second Forbush decrease followed, with an amplitude of 4.0% for cosmic rays of 10 GV obtained with the global survey method. The Dst index reached a minimum value of -204 nT that was detected on 23 June 2015 at 05:00 - 06:00 UT, while the Kp index reached the value eight. For our analysis, we used hourly cosmic-ray intensity data recorded by polar, mid-, and high-latitude neutron monitor stations obtained from the High Resolution Neutron Monitor Database. The cosmic-ray anisotropy variation at the ecliptic plane was also estimated and was found to be highly complex. We study and discuss the unusual and complex cosmic-ray and geomagnetic response to these solar events.
Synchrotron radiation based beam diagnostics at the Fermilab Tevatron
Thurman-Keup, R.; Cheung, H. W. K.; Hahn, A.; ...
2011-09-16
Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transversemore » beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.« less
Li, Xuejian; Wang, Youqing
2016-12-01
Offline general-type models are widely used for patients' monitoring in intensive care units (ICUs), which are developed by using past collected datasets consisting of thousands of patients. However, these models may fail to adapt to the changing states of ICU patients. Thus, to be more robust and effective, the monitoring models should be adaptable to individual patients. A novel combination of just-in-time learning (JITL) and principal component analysis (PCA), referred to learning-type PCA (L-PCA), was proposed for adaptive online monitoring of patients in ICUs. JITL was used to gather the most relevant data samples for adaptive modeling of complex physiological processes. PCA was used to build an online individual-type model and calculate monitoring statistics, and then to judge whether the patient's status is normal or not. The adaptability of L-PCA lies in the usage of individual data and the continuous updating of the training dataset. Twelve subjects were selected from the Physiobank's Multi-parameter Intelligent Monitoring for Intensive Care II (MIMIC II) database, and five vital signs of each subject were chosen. The proposed method was compared with the traditional PCA and fast moving-window PCA (Fast MWPCA). The experimental results demonstrated that the fault detection rates respectively increased by 20 % and 47 % compared with PCA and Fast MWPCA. L-PCA is first introduced into ICU patients monitoring and achieves the best monitoring performance in terms of adaptability to changes in patient status and sensitivity for abnormality detection.
Respiration rate detection based on intensity modulation using plastic optical fiber
NASA Astrophysics Data System (ADS)
Anwar, Zawawi Mohd; Ziran Nurul Sufia, Nor; Hadi, Manap
2017-11-01
This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.
Thirty-one years of debris-flow observation and monitoring near La Honda, California, USA
Wieczorek, G.F.; Wilson, R.C.; Ellen, S.D.; Reid, M.E.; Jayko, A.S.
2007-01-01
From 1975 until 2006,18 intense storms triggered at least 248 debris flows within 10 km2 northwest of the town of La Honda within the Santa Cruz Mountains, California. In addition to mapping debris flows and other types of landslides, studies included soil sampling and geologic mapping, piezometric and tensiometer monitoring, and rainfall measurement and recording. From 1985 until 1995, a system with radio telemetered rain gages and piezometers within the La Honda region was used for issuing six debris-flow warnings within the San Francisco Bay region through the NOAA ALERT system. Depending upon the relative intensity of rainfall during storms, debris flows were generated from deep slumps, shallow slumps, shallow slides in colluvium and shallow slides over bedrock. Analysis shows the storms with abundant antecedent rainfall followed by several days of steady heavy intense rainfall triggered the most abundant debris flows. ?? 2007 millpress.
Ultraviolet laser beam monitor using radiation responsive crystals
McCann, Michael P.; Chen, Chung H.
1988-01-01
An apparatus and method for monitoring an ultraviolet laser beam includes disposing in the path of an ultraviolet laser beam a substantially transparent crystal that will produce a color pattern in response to ultraviolet radiation. The crystal is exposed to the ultraviolet laser beam and a color pattern is produced within the crystal corresponding to the laser beam intensity distribution therein. The crystal is then exposed to visible light, and the color pattern is observed by means of the visible light to determine the characteristics of the laser beam that passed through crystal. In this manner, a perpendicular cross sectional intensity profile and a longitudinal intensity profile of the ultraviolet laser beam may be determined. The observation of the color pattern may be made with forward or back scattered light and may be made with the naked eye or with optical systems such as microscopes and television cameras.
Traffic intensity monitoring using multiple object detection with traffic surveillance cameras
NASA Astrophysics Data System (ADS)
Hamdan, H. G. Muhammad; Khalifah, O. O.
2017-11-01
Object detection and tracking is a field of research that has many applications in the current generation with increasing number of cameras on the streets and lower cost for Internet of Things(IoT). In this paper, a traffic intensity monitoring system is implemented based on the Macroscopic Urban Traffic model is proposed using computer vision as its source. The input of this program is extracted from a traffic surveillance camera which has another program running a neural network classification which can identify and differentiate the vehicle type is implanted. The neural network toolbox is trained with positive and negative input to increase accuracy. The accuracy of the program is compared to other related works done and the trends of the traffic intensity from a road is also calculated. relevant articles in literature searches, great care should be taken in constructing both. Lastly the limitation and the future work is concluded.
Development of an Intelligent Monitoring System for Geological Carbon Sequestration (GCS) Systems
NASA Astrophysics Data System (ADS)
Sun, A. Y.; Jeong, H.; Xu, W.; Hovorka, S. D.; Zhu, T.; Templeton, T.; Arctur, D. K.
2016-12-01
To provide stakeholders timely evidence that GCS repositories are operating safely and efficiently requires integrated monitoring to assess the performance of the storage reservoir as the CO2 plume moves within it. As a result, GCS projects can be data intensive, as a result of proliferation of digital instrumentation and smart-sensing technologies. GCS projects are also resource intensive, often requiring multidisciplinary teams performing different monitoring, verification, and accounting (MVA) tasks throughout the lifecycle of a project to ensure secure containment of injected CO2. How to correlate anomaly detected by a certain sensor to events observed by other devices to verify leakage incidents? How to optimally allocate resources for task-oriented monitoring if reservoir integrity is in question? These are issues that warrant further investigation before real integration can take place. In this work, we are building a web-based, data integration, assimilation, and learning framework for geologic carbon sequestration projects (DIAL-GCS). DIAL-GCS will be an intelligent monitoring system (IMS) for automating GCS closed-loop management by leveraging recent developments in high-throughput database, complex event processing, data assimilation, and machine learning technologies. Results will be demonstrated using realistic data and model derived from a GCS site.
Reliability of Beam Loss Monitor Systems for the Large Hadron Collider
NASA Astrophysics Data System (ADS)
Guaglio, G.; Dehning, B.; Santoni, C.
2005-06-01
The increase of beam energy and beam intensity, together with the use of super conducting magnets, opens new failure scenarios and brings new criticalities for the whole accelerator protection system. For the LHC beam loss protection system, the failure rate and the availability requirements have been evaluated using the Safety Integrity Level (SIL) approach. A downtime cost evaluation is used as input for the SIL approach. The most critical systems, which contribute to the final SIL value, are the dump system, the interlock system, the beam loss monitors system, and the energy monitor system. The Beam Loss Monitors System (BLMS) is critical for short and intense particles losses at 7 TeV and assisted by the Fast Beam Current Decay Monitors at 450 GeV. At medium and higher loss time it is assisted by other systems, such as the quench protection system and the cryogenic system. For BLMS, hardware and software have been evaluated in detail. The reliability input figures have been collected using historical data from the SPS, using temperature and radiation damage experimental data as well as using standard databases. All the data has been processed by reliability software (Isograph). The analysis spaces from the components data to the system configuration.
Biggins, Dean E.; Godbey, Jerry L.; Matchett, Marc R.; Hanebury, Louis R.; Livieri, Travis M.; Marinari, Paul E.
2006-01-01
Although the monitoring of black-footed ferret (Mustela nigripes) populations following reintroductions has not been haphazard, several ferret recovery groups since 1994 have recommended development of uniform standards prescribing minimum methods, intensities, and frequencies of monitoring that would provide data on population size, mortality rates, and recruitment. Such standards would promote comparability of data among sites, document expectations for those who will attempt to establish new populations, and allow the U.S. Fish and Wildlife Service and other responsible groups to better assess progress made toward achieving recovery objectives. Our recommendations are based on methods that have been successfully used to monitor natural and reintroduced populations of ferrets and are an attempt to balance needs and costs. We suggest a combination of marking ferrets with passive integrated transponder (PIT) tags and annual spotlight searches coupled with automated transponder readers to individually identify survivors. Unmarked ferrets should be captured and implanted with PIT tags whenever possible. These and other methods are detailed. Circumstances that may dictate other methods or more intensive monitoring (e.g., high rates of loss or low recruitment) also are discussed.
NASA Astrophysics Data System (ADS)
Michalzik, Beate; Bischoff, Sebastian; Levia, Delphis; Schwarz, Martin; Escher, Peter; Wilcke, Wolfgang; Thieme, Lisa; Kerber, Katja; Kaupenjohann, Martin; Siemens, Jan
2017-04-01
In forested ecosystems, throughfall and stemflow function as key components in the cycling of water and associated biogeochemistry. Analysing annual flux data collected from 27 intensively monitored forest sites of the Biodiversity Exploratories, we found throughfall fluxes of DOC (dissolved organic carbon) linearly related (R2 = 0.40, p < 0.001) to the silvicultural management intensity indicator (SMI) developed by Schall and Ammer (2013). The SMI combines tree species, stand age and aboveground living and dead woody biomass, thereby allowing the quantifying of silvicultural management intensities of stands differing in species composition, age, silvicultural system as they convert from one stand type into another. Throughfall fluxes of particulate organic C and N (POC and PN) and dissolved N were, however independent from those forest structural metrics as well as annual C and N stemflow fluxes, which varied greatly among management intensity classes. In this context, we suggest that canopy structure metrics are more important drivers of water and matter stemflow dynamics, than structural metrics on the level of forest stands. On the other hand, leaching losses of DOC and POC from the litter layer of forests increased significantly with increasing forest management intensity. The observed relationships revealed by intensive flux monitoring are important because they allow us to link organic matter fluxes to forest metrics of larger forested areas (e.g. derived from LiDAR imagery), and hence to model and up-scale water-bound OC dynamics to the landscape level.
The Ohio River Valley Sanitation Commission (ORSANCO) is a compact of eight states representing interests in the Ohio River basin that has been instrumental in the development of biological monitoring of the Ohio River. In the past, ORSANCO has conducted intensive surveys by samp...
Impact of vegetation control and annual fertilization on properties of loblolly pine wood at age 12
Alexander Clark; Bruce E. Borders; Richard F. Daniels
2004-01-01
Loblolly pine (Pinus taeda L.) stands in the Coastal Plain and Piedmont of Georgia were subjected to four intensive silvicultural regimes to monitor and record relative tree growth. Treatments included: intensive mechanical site preparation, complete vegetation control with multiple applications of herbicides, annual high rates of nitrogen...
ERIC Educational Resources Information Center
Woo, Minjung; Kim, Sungwoon; Kim, Jingu; Petruzzello, Steven J.; Hatfield, Bradley D.
2010-01-01
The "feel better" effect of exercise has been well established, but the optimal intensity needed to elicit a positive affective response is controversial. In addition, the mechanisms underlying such a response are unclear. To clarify these issues, female undergraduate students were monitored for electroencephalographic (EEG) and self-reported…
Monitoring tropical cyclone intensity using wind fields derived from short-interval satellite images
NASA Technical Reports Server (NTRS)
Rodgers, E. B.; Gentry, R. C.
1981-01-01
Rapid scan visible images from the Visible Infrared Spin Scan Radiometer sensor on board SMS-2 and GOES-1 were used to derive high resolution upper and lower tropospheric environmental wind fields around three western Atlantic tropical cyclones (1975-78). These wind fields were used to derive upper and lower tropospheric areal mean relative vorticity and their differences, the net relative angular momentum balance and upper tropospheric mass outflow. These kinematic parameters were shown by studies using composite rawinsonde data to be strongly related to tropical cyclone formation and intensity changes. Also, the role of forced synoptic scale subsidence in tropical cyclone formation was examined. The studies showed that satellite-derived lower and upper tropospheric wind fields can be used to monitor and possibly predict tropical cyclone formation and intensity changes. These kinematic analyses showed that future changes in tropical cyclone intensity are mainly related to the "spin-up" of the storms by the net horizontal transport of relative angular momentum caused by convergence of cyclonic vorticity in the lower troposphere and to a lesser extent the divergence of anticyclone vorticity in the upper troposphere.
Sazgarnia, Ameneh; Shanei, Ahmad; Shanei, Mohammad Mahdi
2014-01-01
One of the most important challenges in medical treatment is invention of a minimally invasive approach in order to induce lethal damages to cancer cells. Application of high intensity focused ultrasound can be beneficial to achieve this goal via the cavitation process. Existence of the particles and vapor in a liquid decreases the ultrasonic intensity threshold required for cavitation onset. In this study, synergism of intense pulsed light (IPL) and gold nanoparticles (GNPs) has been investigated as a means of providing nucleation sites for acoustic cavitation. Several approaches have been reported with the aim of cavitation monitoring. We conducted the experiments on the basis of sonochemiluminescence (SCL) and chemical dosimetric methods. The acoustic cavitation activity was investigated by determining the integrated SCL signal acquired over polyacrylamide gel phantoms containing luminol in the presence and absence of GNPs in the wavelength range of 400-500 nm using a spectrometer equipped with cooled charged coupled devices (CCD) during irradiation by different intensities of 1 MHz ultrasound and IPL pulses. In order to confirm these results, the terephthalic acid chemical dosimeter was utilized as well. The SCL signal recorded in the gel phantoms containing GNPs at different intensities of ultrasound in the presence of intense pulsed light was higher than the gel phantoms without GNPs. These results have been confirmed by the obtained data from the chemical dosimetry method. Acoustic cavitation in the presence of GNPs and intense pulsed light has been suggested as a new approach designed for decreasing threshold intensity of acoustic cavitation and improving targeted therapeutic effects. Copyright © 2013 Elsevier B.V. All rights reserved.
Distribution of photon absorption rates across the rat retina.
Williams, T P; Webbers, J P; Giordano, L; Henderson, R P
1998-04-15
1. An investigation into the distribution of light intensity across the rat retina was carried out on excised, intact rat eyes exposed to Ganzfeld illumination from a helium-neon laser (543 nm). 2. Some of the light entering the eyes exits through the sclera where its intensity can be monitored with an optical 'pick-up' that samples the intensity coming from a small region of external sclera and underlying retina. The spatial resolution of the pick-up is such that it samples light that has passed through ca 2 % of the rods in the rat eye. 3. Some of the laser light is absorbed by the rod pigment, rhodopsin, which gradually bleaches. Bleaching in the retina, in turn, causes an exponential increase in intensity emanating from the sclera. By monitoring this intensity increase, we are able to measure two important parameters in a single bleaching run: the local rhodopsin concentration and the local intensity falling on the rods. 4. With an ocular transmission photometer, we have measured both the local intensity and the local rhodopsin concentration across wide regions of rat retina. Both pigmented and albino rats were studied. 5. The distributions of rhodopsin and intensity were both nearly uniform; consequently, the product, (rhodopsin concentration) x (intensity), was similarly nearly equal across the retina. This means that the initial rate of photon absorption is about the same at all retinal locations. 6. Interpreted in terms of photostasis (the regulation of daily photon catch), this means that the rate of photon absorption is about the same in each rod, viz. 14 400 photons absorbed per rod per second. Since this rate of absorption is sufficient to saturate the rod, one possible purpose of photostasis is to maintain the rod system in a saturated state during daylight hours.
NASA Astrophysics Data System (ADS)
Goyenola, Guillermo; Meerhof, Mariane; Teixeira de Mello, Franco; González-Bergonzoni, Ivan; Graeber, Daniel; Vidal, Nicolas; Mazzeo, Nestor; Ovesen, Niels; Jeppesen, Erik; Thodsen, Hans; Kronvang, Brian
2014-05-01
Climate is changing towards more extreme conditions all over the world. At the same time, land use is becoming more intensive worldwide and particularly in many developing countries, whereas several developed countries are trying to reduce the impacts of intensive agricultural production and lower the excessive nutrient loading and eutrophication symptoms in water bodies. In 2009, we initiated a comparative research project between the subtropical region (Uruguay) and the temperate region (Denmark) to compare the hydrology and nutrient fluxes in paired micro-catchments with extensive production or intensive agriculture. The four selected streams drained catchments of similar size (7 to 19 km2). We have established similarly equipped monitoring stations in the four micro-catchments in spring (November 2009, Uruguay; March 2010, Denmark) to monitor the effects of land use and agriculture intensity on stream hydrology and nutrient concentrations and fluxes under different climate conditions. We have conducted high frequency measurements in the four lowland streams with underwater probes (turbidity, pH, conductivity and oxygen measured every 15 minutes), fortnight grab sampling of water and automatic sampling of composite water samples for nutrient analysis (total and dissolved nitrogen and phosphorus; sampled every four hours and accumulated fortnightly). Moreover, water level and meteorological information (precipitation, air temperature, global radiation, humidity) has been recorded every 10 minutes and instantaneous flow measurements have been conducted at regular intervals, to facilitate the calculation of instantaneous discharge from continuous records of water level (stage-discharge relationships). We will show results of ca. 2 years from this comparative study between Uruguay and Denmark, and the importance of differences in climate and land use will be discussed.
Large extents of intensive land use limit community reorganization during climate warming.
Oliver, Tom H; Gillings, Simon; Pearce-Higgins, James W; Brereton, Tom; Crick, Humphrey Q P; Duffield, Simon J; Morecroft, Michael D; Roy, David B
2017-06-01
Climate change is increasingly altering the composition of ecological communities, in combination with other environmental pressures such as high-intensity land use. Pressures are expected to interact in their effects, but the extent to which intensive human land use constrains community responses to climate change is currently unclear. A generic indicator of climate change impact, the community temperature index (CTI), has previously been used to suggest that both bird and butterflies are successfully 'tracking' climate change. Here, we assessed community changes at over 600 English bird or butterfly monitoring sites over three decades and tested how the surrounding land has influenced these changes. We partitioned community changes into warm- and cold-associated assemblages and found that English bird communities have not reorganized successfully in response to climate change. CTI increases for birds are primarily attributable to the loss of cold-associated species, whilst for butterflies, warm-associated species have tended to increase. Importantly, the area of intensively managed land use around monitoring sites appears to influence these community changes, with large extents of intensively managed land limiting 'adaptive' community reorganization in response to climate change. Specifically, high-intensity land use appears to exacerbate declines in cold-adapted bird and butterfly species, and prevent increases in warm-associated birds. This has broad implications for managing landscapes to promote climate change adaptation. © 2017 John Wiley & Sons Ltd.
Faustino, Eduardo Antonio
2007-06-01
In mechanical ventilation, invasive and noninvasive, the knowledge of respiratory mechanic physiology is indispensable to take decisions and into the efficient management of modern ventilators. Monitoring of pulmonary mechanic parameters is been recommended from all the review works and clinical research. The objective of this study was review concepts of pulmonary mechanic and the methods used to obtain measures in the bed side, preparing a rational sequence to obtain this data. It was obtained bibliographic review through data bank LILACS, MedLine and PubMed, from the last ten years. This review approaches parameters of resistance, pulmonary compliance and intrinsic PEEP as primordial into comprehension of acute respiratory failure and mechanic ventilatory support, mainly in acute respiratory distress syndrome (ARDS) and in chronic obstructive pulmonary disease (COPD). Monitoring pulmonary mechanics in patients under mechanical ventilation in intensive care units gives relevant informations and should be implemented in a rational and systematic way.
Preventing overtraining in athletes in high-intensity sports and stress/recovery monitoring.
Kellmann, M
2010-10-01
In sports, the importance of optimizing the recovery-stress state is critical. Effective recovery from intense training loads often faced by elite athletes can often determine sporting success or failure. In recent decades, athletes, coaches, and sport scientists have been keen to find creative, new methods for improving the quality and quantity of training for athletes. These efforts have consistently faced barriers, including overtraining, fatigue, injury, illness, and burnout. Physiological and psychological limits dictate a need for research that addresses the avoidance of overtraining, maximizes recovery, and successfully negotiates the fine line between high and excessive training loads. Monitoring instruments like the Recovery-Stress Questionnaire for Athletes can assist with this research by providing a tool to assess their perceived state of recovery. This article will highlight the importance of recovery for elite athletes and provide an overview of monitoring instruments. © 2010 John Wiley & Sons A/S.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapeaux, A.; Schell, D.
2013-06-01
The Amyris-NREL CRADA is a sub-project of Amyris?s DOE-funded pilot-scale Integrated Biorefinery (IBR). The primary product of the Amyris IBR is Amyris Renewable Diesel. Secondary products will include lubricants, polymers and other petro-chemical substitutes. Amyris and its project partners will execute on a rapid project to integrate and leverage their collective expertise to enable the conversion of high-impact biomass feedstocks to these advanced, infrastructure-compatible products. The scope of the Amyris-NREL CRADA includes the laboratory development and pilot scale-up of bagasse pretreatment and enzymatic saccharification conditions by NREL for subsequent conversion of lignocellulosic sugar streams to Amyris Diesel and chemical productsmore » by Amyris. The CRADA scope also includes a techno-economic analysis of the overall production process of Amyris products from high-impact biomass feedstocks.« less
NASA Technical Reports Server (NTRS)
Taranik, J. V.; Noble, D. C.; Hsu, L. C.; Hutsinpiller, A.; Spatz, D.
1986-01-01
Surface coatings on volcanic rock assemblages that occur at select tertiary volcanic centers in southern Nevada were investigated using LANDSAT 5 Thematic Mapper imagery. Three project sites comprise the subject of this study: the Kane Springs Wash, Black Mountain, and Stonewall Mountain volcanic centers. LANDSAT 5 TM work scenes selected for each area are outlined along with local area geology. The nature and composition of surface coatings on the rock types within the subproject areas are determined, along with the origin of the coatings and their genetic link to host rocks, geologic interpretations are related to remote sensing units discriminated on TM imagery. Image processing was done using an ESL VAX/IDIMS image processing system, field sampling, and observation. Aerial photographs were acquired to facilitate location on the ground and to aid stratigraphic differentiation.
Bozorgnia, Yousef; Abrahamson, Norman A.; Al Atik, Linda; Ancheta, Timothy D.; Atkinson, Gail M.; Baker, Jack W.; Baltay, Annemarie S.; Boore, David M.; Campbell, Kenneth W.; Chiou, Brian S.J.; Darragh, Robert B.; Day, Steve; Donahue, Jennifer; Graves, Robert W.; Gregor, Nick; Hanks, Thomas C.; Idriss, I. M.; Kamai, Ronnie; Kishida, Tadahiro; Kottke, Albert; Mahin, Stephen A.; Rezaeian, Sanaz; Rowshandel, Badie; Seyhan, Emel; Shahi, Shrey; Shantz, Tom; Silva, Walter; Spudich, Paul A.; Stewart, Jonathan P.; Watson-Lamprey, Jennie; Wooddell, Kathryn; Youngs, Robert
2014-01-01
The NGA-West2 project is a large multidisciplinary, multi-year research program on the Next Generation Attenuation (NGA) models for shallow crustal earthquakes in active tectonic regions. The research project has been coordinated by the Pacific Earthquake Engineering Research Center (PEER), with extensive technical interactions among many individuals and organizations. NGA-West2 addresses several key issues in ground-motion seismic hazard, including updating the NGA database for a magnitude range of 3.0–7.9; updating NGA ground-motion prediction equations (GMPEs) for the “average” horizontal component; scaling response spectra for damping values other than 5%; quantifying the effects of directivity and directionality for horizontal ground motion; resolving discrepancies between the NGA and the National Earthquake Hazards Reduction Program (NEHRP) site amplification factors; analysis of epistemic uncertainty for NGA GMPEs; and developing GMPEs for vertical ground motion. This paper presents an overview of the NGA-West2 research program and its subprojects.
Model-Invariant Hybrid Computations of Separated Flows for RCA Standard Test Cases
NASA Technical Reports Server (NTRS)
Woodruff, Stephen
2016-01-01
NASA's Revolutionary Computational Aerosciences (RCA) subproject has identified several smooth-body separated flows as standard test cases to emphasize the challenge these flows present for computational methods and their importance to the aerospace community. Results of computations of two of these test cases, the NASA hump and the FAITH experiment, are presented. The computations were performed with the model-invariant hybrid LES-RANS formulation, implemented in the NASA code VULCAN-CFD. The model- invariant formulation employs gradual LES-RANS transitions and compensation for model variation to provide more accurate and efficient hybrid computations. Comparisons revealed that the LES-RANS transitions employed in these computations were sufficiently gradual that the compensating terms were unnecessary. Agreement with experiment was achieved only after reducing the turbulent viscosity to mitigate the effect of numerical dissipation. The stream-wise evolution of peak Reynolds shear stress was employed as a measure of turbulence dynamics in separated flows useful for evaluating computations.
Measuring surface flow velocity with smartphones: potential for citizen observatories
NASA Astrophysics Data System (ADS)
Weijs, Steven V.; Chen, Zichong; Brauchli, Tristan; Huwald, Hendrik
2014-05-01
Stream flow velocity is an important variable for discharge estimation and research on sediment dynamics. Given the influence of the latter on rating curves (stage-discharge relations), and the relative scarcity of direct streamflow measurements, surface velocity measurements can offer important information for, e.g., flood warning, hydropower, and hydrological science and engineering in general. With the growing amount of sensing and computing power in the hands of more outdoorsy individuals, and the advances in image processing techniques, there is now a tremendous potential to obtain hydrologically relevant data from motivated citizens. This is the main focus of the interdisciplinary "WeSenseIt" project, a citizen observatory of water. In this subproject, we investigate the feasibility of stream flow surface velocity measurements from movie clips taken by (smartphone-) cameras. First results from movie-clip derived velocity information will be shown and compared to reference measurements.
Status of ERA Airframe Technology Demonstrators
NASA Technical Reports Server (NTRS)
Davis, Pamela; Jegley, Dawn; Rigney, Tom
2015-01-01
NASA has created the Environmentally Responsible Aviation (ERA) Project to explore and document the feasibility, benefits and technical risk of advanced vehicle configurations and enabling technologies that will reduce the impact of aviation on the environment. A critical aspect of this pursuit is the development of a lighter, more robust airframe that will enable the introduction of unconventional aircraft configurations that have higher lift-to-drag ratios, reduced drag, and lower community noise. The Airframe Technology subproject contains two elements. Under the Damage Arresting Composite Demonstration an advanced material system is being explored which will lead to lighter airframes that are more structural efficient than the composites used in aircraft today. Under the Adaptive Compliant Trailing Edge Flight Experiment a new concept of a flexible wing trailing edge is being evaluated which will reduce weight and improve aerodynamic performance. This presentation will describe the development these two airframe technologies.
Hybrid Electric Propulsion Technologies for Commercial Transports
NASA Technical Reports Server (NTRS)
Bowman, Cheryl; Jansen, Ralph; Jankovsky, Amy
2016-01-01
NASA Aeronautics Research Mission Directorate has set strategic research thrusts to address the major drivers of aviation such as growth in demand for high-speed mobility, addressing global climate and capitalizing in the convergence of technological advances. Transitioning aviation to low carbon propulsion is one of the key strategic research thrust and drives the search for alternative and greener propulsion system for advanced aircraft configurations. This work requires multidisciplinary skills coming from multiple entities. The Hybrid Gas-Electric Subproject in the Advanced Air Transportation Project is energizing the transport class landscape by accepting the technical challenge of identifying and validating a transport class aircraft with net benefit from hybrid propulsion. This highly integrated aircraft of the future will only happen if airframe expertise from NASA Langley, modeling and simulation expertise from NASA Ames, propulsion expertise from NASA Glenn, and the flight research capabilities from NASA Armstrong are brought together to leverage the rich capabilities of U.S. Industry and Academia.
Diorio, Caroline; Celis Ekstrand, Amanda; Hesser, Tanya; O'Sullivan, Cathy; Lee, Michelle; Schechter, Tal; Sung, Lillian
2016-09-01
Purpose Fatigue is an important problem in children receiving intensive chemotherapy and hematopoietic stem cell transplantation (HSCT). Exercise may be an effective intervention for fatigue. Individualized yoga represents an ideal intervention because it can be tailored according to an individual child's needs. Little is known about how to structure a standardized yoga program for intensivelytreated children. Therefore, this study describes the development of a yoga program and an approach to monitoring sessions suitable for hospitalized children receiving intensive chemotherapy or HSCT. Methods The yoga program was designed to increase mobility in hospitalized children and to provide children with relaxation techniques that could be used independently in a variety of environments. The program was founded on 4 key tenets: safety, adaptability, environmental flexibility, and appeal to children. We also developed quality and consistency assurance procedures. Results A menu format with a fixed structure was selected for the yoga program. Each yoga session contained up to 6 sections: breathing exercises, warmup exercises, yoga poses, balancing poses, cool-down poses, and final relaxation. Yoga instructors selected specific yoga poses for each session from a predetermined list organized by intensity level (low, moderate, or high). Monitoring procedures were developed using videotaping and multirater adjudication. Conclusion We created a standardized yoga program and an approach to monitoring that are now ready for incorporation in clinical trials. Future work should include the adaptation of the program to different pediatric populations and clinical settings. © The Author(s) 2016.
How 21st century droughts affect food and environmental security
NASA Astrophysics Data System (ADS)
Kogan, Felix
The first 13th years of the 21st century has begun with a series of widespread, long and intensive droughts around the world. Extreme and severe-to-extreme intensity droughts covered 2-6% and 7-16% of the world land, respectively, affecting environment, economies and humans. These droughts reduced agricultural production, leading to food shortages, human health deterioration, poverty, regional disturbances, population migration and death. This presentation is a travelogue of the 21st century global and regional droughts during the warmest years of the past 100 years. These droughts were identified and monitored with the NOAA operational space technology, called Vegetation Health (VH), which has the longest period of observation and provide good data quality. The VH method was used for assessment of vegetation condition or health, including drought early detection and monitoring. The VH method is based on operational satellites data estimating both land surface greenness (NDVI) and thermal conditions. The 21st century droughts in the USA, Russia, Australia Argentina, Brazil, China, India and other principal grain producing countries were intensive, long, covered large areas and caused huge losses in agricultural production, which affected food and environmental security and led to food riots in some countries. This presentation investigate how droughts affect food and environmental security, if they can be detected earlier, how to monitor their area, intensity, duration and impacts and also their dynamics during the climate warming era with satellite-based vegetation health technology.
Gap and stripline combined monitor
Yin, Yan
1986-01-01
A combined gap and stripline monitor device (10) for measuring the intensity and position of a charged particle beam bunch in a beam pipe of a synchotron radiation facility. The monitor has first and second beam pipe portions (11a, 11b) with an axial gap (12) therebetween. An outer pipe (14) cooperates with the first beam pipe portion (11a) to form a gap enclosure, while inner strips (23a-d) cooperate with the first beam pipe portion (11a) to form a stripline monitor, with the stripline length being the same as the gap enclosure length.
Why are we prolonging QT interval monitoring?
Barrett, Trina
2015-01-01
At present, monitoring of the QT interval (QTI) is not a standard practice in the medical intensive care unit setting, where many drugs that prolong the QTI are administered. This literature review looked at the current research for evidence-based standards to support QTI monitoring of patients with risk factors for QTI prolongation, which can result in life-threatening arrhythmias such as torsade de pointes. The objective of this article is to establish the existence of evidence-based standards for monitoring of the QTI and to raise awareness in the nursing profession of the need for such monitoring among patients who are at high risk for prolonged QTI. To determine whether published standards for QTI monitoring exist, a search was conducted of the bibliographic databases CINAHL, EBSCOhost, Medline, PubMed, Google Scholar, and the Cochrane Library for the years 2013 and 2014. Also, a survey was conducted to determine whether practice standards for QTI monitoring are being implemented at 4 major hospitals in the Memphis area, including a level 1 trauma center. The database search established the existence of published guidelines that support the need for QTI monitoring. Results of the hospital survey indicated that direct care nurses were not aware of the need to identify high-risk patients, drugs with the potential to prolong QTI that were being administered to their patients, or evidence-based standards for QTI monitoring. Review of the research literature underscored the need for QTI monitoring among high-risk patients, that is, those with genetic conditions that predispose them to QTI prolongation, those with existing cardiac conditions being treated with antiarrhythmic medications, or those who are prescribed any new medication classified as high risk on the basis of clinical research. This need is especially crucial in intensive care unit settings, where many antiarrhythmic medications are administered.
Causes of forbush decreases and other cosmic ray variations
NASA Technical Reports Server (NTRS)
Barouch, E.; Burlaga, L. F.
1974-01-01
The relationship between neutron monitor variations and the intensity variations of the interplanetary magnetic field is studied, using Deep River data and IMP-series satellite data. In over 80% of the cases studied, identifiable depressions of the cosmic ray intensity are associated with magnetic field enhancements of several hours duration and intensity above 10 gamma. Conversely, each magnetic field enhancement has an identifiable effect (though not necessarily a marked depression) on the cosmic ray intensity. Long lasting Forbush decreases are found to be the consequence of the successive action of several such features. An explanation is presented and discussed.
Chesnut, Randall M; Temkin, Nancy; Dikmen, Sureyya; Rondina, Carlos; Videtta, Walter; Petroni, Gustavo; Lujan, Silvia; Alanis, Victor; Falcao, Antonio; de la Fuenta, Gustavo; Gonzalez, Luis; Jibaja, Manuel; Lavarden, Arturo; Sandi, Freddy; Mérida, Roberto; Romero, Ricardo; Pridgeon, Jim; Barber, Jason; Machamer, Joan; Chaddock, Kelley
2018-01-01
The imaging and clinical examination (ICE) algorithm used in the Benchmark Evidence from South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial is the only prospectively investigated clinical protocol for traumatic brain injury management without intracranial pressure (ICP) monitoring. As the default literature standard, it warrants careful evaluation. We present the ICE protocol in detail and analyze the demographics, outcome, treatment intensity, frequency of intervention usage, and related adverse events in the ICE-protocol cohort. The 167 ICE protocol patients were young (median 29 years) with a median Glasgow Coma Scale motor score of 4 but with anisocoria or abnormal pupillary reactivity in 40%. This protocol produced outcomes not significantly different from those randomized to the monitor-based protocol (favorable 6-month extended Glasgow Outcome Score in 39%; 41% mortality rate). Agents commonly employed to treat suspected intracranial hypertension included low-/moderate-dose hypertonic saline (72%) and mannitol (57%), mild hyperventilation (adjusted partial pressure of carbon dioxide 30-35 mm Hg in 73%), and pressors to maintain cerebral perfusion (62%). High-dose hyperosmotics or barbiturates were uncommonly used. Adverse event incidence was low and comparable to the BEST TRIP monitored group. Although this protocol should produce similar/acceptable results under circumstances comparable to those in the trial, influences such as longer pre-hospital times and non-specialist transport personnel, plus an intensive care unit model of aggressive physician-intensive care by small groups of neurotrauma-focused intensivists, which differs from most high-resource models, support caution in expecting the same results in dissimilar settings. Finally, this protocol's ICP-titration approach to suspected intracranial hypertension (vs. crisis management for monitored ICP) warrants further study.
Bonner, Oliver; Beardsall, Kathryn; Crilly, Nathan; Lasenby, Joan
2017-02-01
The neonatal intensive care unit (NICU) can be one of the most stressful hospital environments. Alongside providing intensive clinical care, it is important that parents have the opportunity for regular physical contact with their babies because the neonatal period is critical for parent-child bonding. At present, monitoring technology in the NICU requires multiple wired sensors to track each baby's vital signs. This study describes the experiences that parents and nurses have with the current monitoring methods, and reports on their responses to the concept of a wireless monitoring system. Semistructured interviews were conducted with six parents, each of whom had babies on the unit, and seven nurses who cared for those babies. The interviews initially focused on the participants' experiences of the current wired system and then on their responses to the concept of a wireless system. The transcripts were analysed using a general inductive approach to identify relevant themes. Participants reported on physical and psychological barriers to parental care, the ways in which the current system obstructed the efficient delivery of clinical care and the perceived benefits and risks of a wireless system. The parents and nurses identified that the wires impeded baby-parent bonding; physically and psychologically. While a wireless system was viewed as potentially enabling greater interaction, staff and parents highlighted potential concerns, including the size, weight and battery life of any new device. The many wires required to safely monitor babies within the NICU creates a negative environment for parents at a critical developmental period, in terms of physical and psychological interactions. Nurses also experience challenges with the existing system, which could negatively impact the clinical care delivery. Developing a wireless system could overcome these barriers, but there remain challenges in designing a device suitable for this unique environment.
Lake Michigan, the sixth largest freshwater lake in the world by surface area, was utilized as a water body for assessment within a case study. Field data collected at 116 sediment sampling sites throughout the lake in an intensive monitoring effort were utilized for assessment ...
7 CFR 759.5 - Secretarial disaster area determination and notification process.
Code of Federal Regulations, 2013 CFR
2013-01-01
... § 759.5 Secretarial disaster area determination and notification process. (a) U.S. Drought Monitor. With respect to drought and without requiring an LAR: (1) If any portion of a county is physically located in an area with a Drought Monitor Intensity Classification value of D3 (drought-extreme) or higher...
7 CFR 759.5 - Secretarial disaster area determination and notification process.
Code of Federal Regulations, 2014 CFR
2014-01-01
... § 759.5 Secretarial disaster area determination and notification process. (a) U.S. Drought Monitor. With respect to drought and without requiring an LAR: (1) If any portion of a county is physically located in an area with a Drought Monitor Intensity Classification value of D3 (drought-extreme) or higher...
Individual snag detection using neighborhood attribute filtered airborne lidar data
Brian M. Wing; Martin W. Ritchie; Kevin Boston; Warren B. Cohen; Michael J. Olsen
2015-01-01
The ability to estimate and monitor standing dead trees (snags) has been difficult due to their irregular and sparse distribution, often requiring intensive sampling methods to obtain statistically significant estimates. This study presents a new method for estimating and monitoring snags using neighborhood attribute filtered airborne discrete-return lidar data. The...
Traditionally, the EPA has monitored aquatic ecosystems using statistically rigorous sample designs and intensive field efforts which provide high quality datasets. But by their nature they leave many aquatic systems unsampled, follow a top down approach, have a long lag between ...
NASA Technical Reports Server (NTRS)
Saeed, M.; Lieu, C.; Raber, G.; Mark, R. G.
2002-01-01
Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.
A beam monitor based on MPGD detectors for hadron therapy
NASA Astrophysics Data System (ADS)
Altieri, P. R.; Di Benedetto, D.; Galetta, G.; Intonti, R. A.; Mercadante, A.; Nuzzo, S.; Verwilligen, P.
2018-02-01
Remarkable scientific and technological progress during the last years has led to the construction of accelerator based facilities dedicated to hadron therapy. This kind of technology requires precise and continuous control of position, intensity and shape of the ions or protons used to irradiate cancers. Patient safety, accelerator operation and dose delivery should be optimized by a real time monitoring of beam intensity and profile during the treatment, by using non-destructive, high spatial resolution detectors. In the framework of AMIDERHA (AMIDERHA - Enhanced Radiotherapy with HAdron) project funded by the Ministero dell'Istruzione, dell'Università e della Ricerca (Italian Ministry of Education and Research) the authors are studying and developing an innovative beam monitor based on Micro Pattern Gaseous Detectors (MPDGs) characterized by a high spatial resolution and rate capability. The Monte Carlo simulation of the beam monitor prototype was carried out to optimize the geometrical set up and to predict the behavior of the detector. A first prototype has been constructed and successfully tested using 55Fe, 90Sr and also an X-ray tube. Preliminary results on both simulations and tests will be presented.
Monitoring and Modeling Carbon Dynamics at a Network of Intensive Sites in the USA and Mexico
NASA Astrophysics Data System (ADS)
Birdsey, R.; Wayson, C.; Johnson, K. D.; Pan, Y.; Angeles, G.; De Jong, B. H.; Andrade, J. L.; Dai, Z.
2013-05-01
The Forest Services of the USA and Mexico, supported by NASA and USAID, have begun to establish a network of intensive forest carbon monitoring sites. These sites are used for research and teaching, developing forest management practices, and forging links to the needs of communities. Several of the sites have installed eddy flux towers to basic meteorology data and daily estimates of forest carbon uptake and release, the processes that determine forest growth. Field sampling locations at each site provide estimates of forest biomass and carbon stocks, and monitor forest dynamic processes such as growth and mortality rates. Remote sensing facilitates scaling up to the surrounding landscapes. The sites support information requirements for implementing programs such as Reducing Emissions from Deforestation and Forest Degradation (REDD+), enabling communities to receive payments for ecosystem services such as reduced carbon emissions or improved forest management. In addition to providing benchmark data for REDD+ projects, the sites are valuable for validating state and national estimates from satellite remote sensing and the national forest inventory. Data from the sites provide parameters for forest models that support strategic management analysis, and support student training and graduate projects. The intensive monitoring sites may be a model for other countries in Latin America. Coordination among sites in the USA, Mexico and other Latin American countries can ensure harmonization of approaches and data, and share experiences and knowledge among countries with emerging opportunities for implementing REDD+ and other conservation programs.
NASA Astrophysics Data System (ADS)
Guardiani, Carlotta; Amabile, Anna Sara; Jochum, Birgit; Ottowitz, David; Supper, Robert
2017-04-01
One of the main precursors for landslide activation/reactivation is intense and prolonged precipitation, with consequent pore water pressure rise due to infiltration of rainfall that seeps into the ground. Monitoring hydrological parameters such as precipitation, water content and pore pressure, in combination with displacement analysis for early warning purposes, is necessary to understand the triggering processes. Since the reduction over time of electrical resistivity corresponds to an increase of water content, electrical resistivity monitoring can help to interpret the modifications of slope saturation conditions after heavy rainfalls. In this study, we present the results of the ERT monitoring data from two landslide areas, Laakirchen (47.961692N, 13.809897E) and Rosano (44.662453N, 9.104703E). During March 2010, a shallow rotational landslide was triggered by snow melting and intense rainfall in Laakirchen, in the vicinity of a newly constructed house. Laakirchen landslide was monitored by geophysical/geotechnical measurements from September 2011 to June 2013. In December 2004, Rosano landslide reactivation affected rural buildings: slope deformations caused mainly damages to properties, infrastructures and lifelines. Rosano landslide has been defined as a composite landslide, with a general dynamic behavior that can be regarded as a slow earthflow. The installation of the monitoring system took place in July 2012 and the data acquisition lasted until April 2015. These sites are part of the geoelectrical monitoring network set up by the Geological Survey of Austria for testing the self-developed GEOMON4D geoelectrical system, in combination with complementary geotechnical monitoring sensors (rain gauge, automatic inclinometer, water pressure and water content sensors) to support the interpretation of the electrical response of the near surface (R. Supper et al., 2014). The measurements were funded by the TEMPEL project (Austrian Science Fund, TRP 175-N21) and the LAMOND project in the frame of the ESS program of the Austrian Academy of Science. Focusing on the most intense precipitation events, the apparent resistivity data have been processed with an innovative 4D-inversion algorithm (J. H. Kim, 2009, developed within the cooperation between GSA and KIGAM). The results show that intense rainfalls have a direct and immediate impact on resistivity pattern, causing identifiable reductions (around 10%) in the near surface, due to the greater variation of the saturation coefficient. We conclude that long-term resistivity monitoring is capable of providing wide-area knowledge with high spatial resolution about the achievement of a certain degree of saturation in the subsurface. Amabile, A.S. (2016). Geoelectrical methods for landslide monitoring: the case study of Laakirchen, Upper Austria (Unpublished Master thesis). University of Salerno, Fisciano, Italy. Guardiani, C. (2016). Long-term electrical resistivity data analysis for landslide monitoring: the case study of Rosano (Unpublished Master thesis). Politecnico di Milano, Milano, Italy. Kim, J.-H., Yi, M.-J., Park, S.-G., & Kim, J. G. (2009). 4-D inversion of DC resistivity monitoring data acquired over a dynamically changing earth model. Journal of Applied Geophysics, 68(4), 522-532. Supper, R., Ottowitz, D., Jochum, B., Kim, J.-H., Römer, A., Baron, I., S. Pfeiler, M. Lovisolo, S. Gruber and Vecchiotti, F. (2014). Geoelectrical monitoring: an innovative method to supplement landslide surveillance and early warning. Near Surface Geophysics, 12(2007), 133-150.
Approaches that use software to support the prevention of pressure ulcer: A systematic review.
Marchione, F G; Araújo, L M Q; Araújo, L V
2015-10-01
The incidence and costs for pressure ulcer (PU) treatment remain high even though preventive methods are applied. Approaches that use software to support the prevention of PU are presented in the literature to make it more effective. Identify the state of art of the approaches that use software to support the prevention of PUs. A systematic literature review was performed to analyze approaches that use software to support the prevention of PU. ACM, IEEE, PubMed, Scopus, CINAHL and Embase databases have been searched with a predetermined search string to identify primary studies. We selected the ones that met the established inclusion criteria. Thirty-six articles met the inclusion criteria. To support prevention, most approaches monitor the patient to provide information about exposure to pressure, temperature level, humidity level and estimated body position in bed providing risk factor intensity charts and intensity maps. The main method to perform patient's monitoring is using sensors installed on the mattress, but recently, alternative methods have been proposed such as electronic sensors and tactile sensory coils. Part of the approaches performs automated management of the risk factors using ventilation tubes and mattresses with porous cells to decrease body's temperature and movable cells to automatically redistribute the pressure over the body. Matters as cost of the approach, patient comfort and hygiene of the monitoring equipment is only briefly discussed in the selected articles. No experiments have been conducted to evidence the approached may reduce PU incidence. Currently, approaches that use software to support the prevention of PU provide relevant information to health professionals such as risk factor intensity charts and intensity maps. Some of them can even automatically manage risk factors in a limited way. Yet, the approaches are based on risk factor monitoring methods that require patient's contact with the monitoring equipment. Therefore, some matters need to be considered such as patient's comfort and the hygiene or replacement of the equipment due to the risk of infection. With the emergence of new alternative methods of monitoring, new technologies that do not require contact could be explored by new researches. Randomized Control Trials could also be conducted to verify which approaches are really effective to reduce PU incidence. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Confidential inquiry into quality of care before admission to intensive care
McQuillan, Peter; Pilkington, Sally; Allan, Alison; Taylor, Bruce; Short, Alasdair; Morgan, Giles; Nielsen, Mick; Barrett, David; Smith, Gary
1998-01-01
Objective: To examine the prevalence, nature, causes, and consequences of suboptimal care before admission to intensive care units, and to suggest possible solutions. Design: Prospective confidential inquiry on the basis of structured interviews and questionnaires. Setting: A large district general hospital and a teaching hospital. Subjects: A cohort of 100 consecutive adult emergency admissions, 50 in each centre. Main outcome measures: Opinions of two external assessors on quality of care especially recognition, investigation, monitoring, and management of abnormalities of airway, breathing, and circulation, and oxygen therapy and monitoring. Results: Assessors agreed that 20 patients were well managed (group 1) and 54 patients received suboptimal care (group 2). Assessors disagreed on quality of management of 26 patients (group 3). The casemix and severity of illness, defined by the acute physiology and chronic health evaluation (APACHE II) score, were similar between centres and the three groups. In groups 1, 2, and 3 intensive care mortalities were 5 (25%), 26 (48%), and 6 (23%) respectively (P=0.04) (group 1 versus group 2, P=0.07). Hospital mortalities were 7 (35%), 30 (56%), and 8 (31%) (P=0.07) and standardised hospital mortality ratios (95% confidence intervals) were 1.23 (0.49 to 2.54), 1.4 (0.94 to 2.0), and 1.26 (0.54 to 2.48) respectively. Admission to intensive care was considered late in 37 (69%) patients in group 2. Overall, a minimum of 4.5% and a maximum of 41% of admissions were considered potentially avoidable. Suboptimal care contributed to morbidity or mortality in most instances. The main causes of suboptimal care were failure of organisation, lack of knowledge, failure to appreciate clinical urgency, lack of supervision, and failure to seek advice. Conclusions: The management of airway, breathing, and circulation, and oxygen therapy and monitoring in severely ill patients before admission to intensive care units may frequently be suboptimal. Major consequences may include increased morbidity and mortality and requirement for intensive care. Possible solutions include improved teaching, establishment of medical emergency teams, and widespread debate on the structure and process of acute care. Key messages Suboptimal management of oxygen therapy, airway, breathing, circulation, and monitoring before admission to intensive care occurred in over half of a consecutive cohort of acute adult emergency patients. This may be associated with increased morbidity, mortality, and avoidable admissions to intensive care At least 39% of acute adult emergency patients were admitted to intensive care late in the clinical course of the illness Major causes of suboptimal care included failure of organisation, lack of knowledge, failure to appreciate clinical urgency, lack of supervision, and failure to seek advice A medical emergency team may be useful in responding pre-emptively to the clinical signs of life threatening dysfunction of airway, breathing, and circulation, rather than relying on a cardiac arrest team The structure and process of acute care and their importance require major re-evaluation and debate PMID:9632403
Analysis of the readout of a high rate MWPC
NASA Astrophysics Data System (ADS)
Camerini, P.; Grion, N.; Rui, R.; Sheffer, G.; Openshaw, R.
1990-06-01
An analytical method to reduce the raw data supplied by a high-speed multiwire proportional chamber (MWPC) is presented. The results obtained with the MWPC and the associated readout system, LeCroy PCOS III, when monitoring a high-intensity flux of positive pions delivered by the M11 channel at TRIUMF are discussed. The method allows the flux intensity, the beam envelope and the detector efficiency to be determined with little uncertainty (few %) at intense particle beams ( > 10 7 particles/s).
Development of Android based Smart Power Saving System
NASA Astrophysics Data System (ADS)
Gupta, Ashutosh; Kumar, Pradeep; Ghosh, Tathagata; Bhawna, Shruthi. S.
2017-08-01
An android based smart power saving system has been presented in this paper. For this purpose, an application is developed for controlling the intensity of an AC supply using a dimmer circuit in android platform and to monitor the current flow on different intensity level a current sensor is used in the circuit. Dimmer circuit provides a 16-different intensity level to control the flow of current and help in power saving. The system is very simple and robust as it is based on android platform.
Liquid Droplet Thrusters to Provide Constant Momentum Exchange Between Formation Flying Spacecraft
2010-03-01
density; 1070 kg/m3 for DC704 and 1097 kg/m3 for DC705. The fluids differ chemically by a single methyl group, which is replaced by a fifth Benzene...of photon energy. The relative light intensity was monitored by the fluorescence of Sodium Salicylate . Division of the current by the intensity of
Data-Intensive Scientific Management, Analysis and Visualization
NASA Astrophysics Data System (ADS)
Goranova, Mariana; Shishedjiev, Bogdan; Juliana Georgieva, Juliana
2012-11-01
The proposed integrated system provides a suite of services for data-intensive sciences that enables scientists to describe, manage, analyze and visualize data from experiments and numerical simulations in distributed and heterogeneous environment. This paper describes the advisor and the converter services and presents an example from the monitoring of the slant column content of atmospheric minor gases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colleen Iversen; Amy Breen; Verity Salmon
Data includes GPS waypoints for intensive plots, reference points, vegetation plots, and soil temperature/moisture monitoring stations that were established in July 2016 at the Kougarok hill slope located at Kougarok Road, Mile Marker 64. Photographs of all intensive plots and reference points are also included.
NASA Astrophysics Data System (ADS)
Sato, Manabu; Nishidate, Izumi
2014-05-01
We investigated the feasibility of OCT in monitoring the viability of the brain. It was confirmed that after an overdose of pentobarbital sodium salt for an euthanasia, the OCT signal intensity increased before cardiac arrest and finally became 2.7 times, and by periodically changing the tissue temperature from 20 to 32 °C in vivo, average correlation coefficients between the ratio of signal intensity (RSI) and temperature were determined to be -0:42 to -0:50. RSI reversibly changed with subsequent variations of temperatures and finally increased rapidly just before cardiac arrest. These results indicate that RSI could correspond to decreases in viability.
Forrest, Stephen R.; Vartanian, Garen; Rolin, Cedric
2015-06-23
A method for in-situ monitoring of gas-phase photoactive organic molecules in real time while depositing a film of the photoactive organic molecules on a substrate in a processing chamber for depositing the film includes irradiating the gas-phase photoactive organic molecules in the processing chamber with a radiation from a radiation source in-situ while depositing the film of the one or more organic materials and measuring the intensity of the resulting photoluminescence emission from the organic material. One or more processing parameters associated with the deposition process can be determined from the photoluminescence intensity data in real time providing useful feedback on the deposition process.
Novel Tiltmeter for Monitoring Angle Shift In Incident Waves
2008-12-01
40th Annual Precise Time and Time Interval (PTTI) Meeting 559 NOVEL TILTMETER FOR MONITORING ANGLE SHIFT IN INCIDENT WAVES S... Tiltmeter For Monitoring Angle Shift In Incident Waves 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...up, any angle change of the incident beam ’θ results in a change of the intensity transmission of the resonator. A NOVEL ANGLE TILTMETER
Jackson, George L.; Weinberger, Morris; Kirshner, Miriam A.; Stechuchak, Karen M.; Melnyk, Stephanie D.; Bosworth, Hayden B.; Coffman, Cynthia J.; Neelon, Brian; Van Houtven, Courtney; Gentry, Pamela W.; Morris, Isis J.; Rose, Cynthia M.; Taylor, Jennifer P.; May, Carrie L.; Han, Byungjoo; Wainwright, Christi; Alkon, Aviel; Powell, Lesa; Edelman, David
2016-01-01
Despite the availability of efficacious treatments, only half of patients with hypertension achieve adequate blood pressure (BP) control. This paper describes the protocol and baseline subject characteristics of a 2-arm, 18-month randomized clinical trial of titrated disease management (TDM) for patients with pharmaceutically-treated hypertension for whom systolic blood pressure (SBP) is not controlled (≥140mmHg for non-diabetic or ≥130mmHg for diabetic patients). The trial is being conducted among patients of four clinic locations associated with a Veterans Affairs Medical Center. An intervention arm has a TDM strategy in which patients' hypertension control at baseline, 6, and 12 months determines the resource intensity of disease management. Intensity levels include: a low-intensity strategy utilizing a licensed practical nurse to provide bi-monthly, non-tailored behavioral support calls to patients whose SBP comes under control; medium-intensity strategy utilizing a registered nurse to provide monthly tailored behavioral support telephone calls plus home BP monitoring; and high-intensity strategy utilizing a pharmacist to provide monthly tailored behavioral support telephone calls, home BP monitoring, and pharmacist-directed medication management. Control arm patients receive the low-intensity strategy regardless of BP control. The primary outcome is SBP. There are 385 randomized (192 intervention; 193 control) veterans that are predominately older (mean age 63.5 years) men (92.5%). 61.8% are African American, and the mean baseline SBP for all subjects is 143.6mmHg. This trial will determine if a disease management program that is titrated by matching the intensity of resources to patients' BP control leads to superior outcomes compared to a low-intensity management strategy. PMID:27417982
Jackson, George L; Weinberger, Morris; Kirshner, Miriam A; Stechuchak, Karen M; Melnyk, Stephanie D; Bosworth, Hayden B; Coffman, Cynthia J; Neelon, Brian; Van Houtven, Courtney; Gentry, Pamela W; Morris, Isis J; Rose, Cynthia M; Taylor, Jennifer P; May, Carrie L; Han, Byungjoo; Wainwright, Christi; Alkon, Aviel; Powell, Lesa; Edelman, David
2016-09-01
Despite the availability of efficacious treatments, only half of patients with hypertension achieve adequate blood pressure (BP) control. This paper describes the protocol and baseline subject characteristics of a 2-arm, 18-month randomized clinical trial of titrated disease management (TDM) for patients with pharmaceutically-treated hypertension for whom systolic blood pressure (SBP) is not controlled (≥140mmHg for non-diabetic or ≥130mmHg for diabetic patients). The trial is being conducted among patients of four clinic locations associated with a Veterans Affairs Medical Center. An intervention arm has a TDM strategy in which patients' hypertension control at baseline, 6, and 12months determines the resource intensity of disease management. Intensity levels include: a low-intensity strategy utilizing a licensed practical nurse to provide bi-monthly, non-tailored behavioral support calls to patients whose SBP comes under control; medium-intensity strategy utilizing a registered nurse to provide monthly tailored behavioral support telephone calls plus home BP monitoring; and high-intensity strategy utilizing a pharmacist to provide monthly tailored behavioral support telephone calls, home BP monitoring, and pharmacist-directed medication management. Control arm patients receive the low-intensity strategy regardless of BP control. The primary outcome is SBP. There are 385 randomized (192 intervention; 193 control) veterans that are predominately older (mean age 63.5years) men (92.5%). 61.8% are African American, and the mean baseline SBP for all subjects is 143.6mmHg. This trial will determine if a disease management program that is titrated by matching the intensity of resources to patients' BP control leads to superior outcomes compared to a low-intensity management strategy. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Chavez, Carlos; Hammel, Bruce; Hammel, Allan; Moore, John R.
2014-01-01
Unmanned Aircraft Systems (UAS) represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the National Airspace System (NAS). To address this deficiency, NASA has established a project called UAS Integration in the NAS (UAS in the NAS), under the Integrated Systems Research Program (ISRP) of the Aeronautics Research Mission Directorate (ARMD). This project provides an opportunity to transition concepts, technology, algorithms, and knowledge to the Federal Aviation Administration (FAA) and other stakeholders to help them define the requirements, regulations, and issues for routine UAS access to the NAS. The safe, routine, and efficient integration of UAS into the NAS requires new radio frequency (RF) spectrum allocations and a new data communications system which is both secure and scalable with increasing UAS traffic without adversely impacting the Air Traffic Control (ATC) communication system. These data communications, referred to as Control and Non-Payload Communications (CNPC), whose purpose is to exchange information between the unmanned aircraft and the ground control station to ensure safe, reliable, and effective unmanned aircraft flight operation. A Communications Subproject within the UAS in the NAS Project has been established to address issues related to CNPC development, certification and fielding. The focus of the Communications Subproject is on validating and allocating new RF spectrum and data link communications to enable civil UAS integration into the NAS. The goal is to validate secure, robust data links within the allocated frequency spectrum for UAS. A vision, architectural concepts, and seed requirements for the future commercial UAS CNPC system have been developed by RTCA Special Committee 203 (SC-203) in the process of determining formal recommendations to the FAA in its role provided for under the Federal Advisory Committee Act. NASA intends to conduct its research and development in keeping with this vision and associated architectural concepts. The prototype communication systems developed and tested by NASA will be used to validate and update the initial SC-203 requirements in order to provide a foundation for SC-203's Minimum Aviation System Performance Standards (MASPS).
Yan, Luchun; Liu, Jiemin; Jiang, Shen; Wu, Chuandong; Gao, Kewei
2017-07-13
The olfactory evaluation function (e.g., odor intensity rating) of e-nose is always one of the most challenging issues in researches about odor pollution monitoring. But odor is normally produced by a set of stimuli, and odor interactions among constituents significantly influenced their mixture's odor intensity. This study investigated the odor interaction principle in odor mixtures of aldehydes and esters, respectively. Then, a modified vector model (MVM) was proposed and it successfully demonstrated the similarity of the odor interaction pattern among odorants of the same type. Based on the regular interaction pattern, unlike a determined empirical model only fit for a specific odor mixture in conventional approaches, the MVM distinctly simplified the odor intensity prediction of odor mixtures. Furthermore, the MVM also provided a way of directly converting constituents' chemical concentrations to their mixture's odor intensity. By combining the MVM with usual data-processing algorithm of e-nose, a new e-nose system was established for an odor intensity rating. Compared with instrumental analysis and human assessor, it exhibited accuracy well in both quantitative analysis (Pearson correlation coefficient was 0.999 for individual aldehydes ( n = 12), 0.996 for their binary mixtures ( n = 36) and 0.990 for their ternary mixtures ( n = 60)) and odor intensity assessment (Pearson correlation coefficient was 0.980 for individual aldehydes ( n = 15), 0.973 for their binary mixtures ( n = 24), and 0.888 for their ternary mixtures ( n = 25)). Thus, the observed regular interaction pattern is considered an important foundation for accelerating extensive application of olfactory evaluation in odor pollution monitoring.
Klassen, Tara D; Semrau, Jennifer A; Dukelow, Sean P; Bayley, Mark T; Hill, Michael D; Eng, Janice J
2017-09-01
Identifying practical ways to accurately measure exercise intensity and dose in clinical environments is essential to advancing stroke rehabilitation. This is especially relevant in monitoring walking activity during inpatient rehabilitation where recovery is greatest. This study evaluated the accuracy of a readily available consumer-based physical activity monitor during daily inpatient stroke rehabilitation physical therapy sessions. Twenty-one individuals admitted to inpatient rehabilitation were monitored for a total of 471 one-hour physical therapy sessions which consisted of walking and nonwalking therapeutic activities. Participants wore a consumer-based physical activity monitor (Fitbit One) and the gold standard for assessing step count (StepWatch Activity Monitor) during physical therapy sessions. Linear mixed modeling was used to assess the relationship of the step count of the Fitbit to the StepWatch Activity Monitor. Device accuracy is reported as the percent error of the Fitbit compared with the StepWatch Activity Monitor. A strong relationship (slope=0.99; 95% confidence interval, 0.97-1.01) was found between the number of steps captured by the Fitbit One and the StepWatch Activity Monitor. The Fitbit One had a mean error of 10.9% (5.3) for participants with walking velocities <0.4 m/s, 6.8% (3.0) for walking velocities between 0.4 and 0.8 m/s, and 4.4% (2.8) for walking velocities >0.8 m/s. This study provides preliminary evidence that the Fitbit One, when positioned on the nonparetic ankle, can accurately measure walking steps early after stroke during inpatient rehabilitation physical therapy sessions. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01915368. © 2017 American Heart Association, Inc.
Blood perfusion and pH monitoring in organs by laser-induced fluorescence spectroscopy
NASA Astrophysics Data System (ADS)
Vari, Sandor G.; Papazoglou, Theodore G.; Pergadia, Vani R.; Stavridi, Marigo; Snyder, Wendy J.; Papaioannou, Thanassis; Duffy, J. T.; Weiss, Andrew B.; Thomas, Reem; Grundfest, Warren S.
1994-01-01
Sensitivity of laser-induced fluorescence spectroscopy (LIFS) in detecting a change in tissue pH, and blood perfusion was determined. Rabbits were anesthetized, paralyzed, and mechanically ventilated. The arterial and venous blood supplies of the kidney were isolated and ligated to alter the perfusion. The femoral artery was cannulated to extract samples for blood gas analysis. A 308-nm XeCl was used as an excitation source. A 600 micrometers core diameter fiber was used for fluorescence acquisition, and the spectra analyzed by an optical multichannel analyzer (EG & G, OMA III). the corresponding intensity ratio R equals INADH / ICOLL was used as an index for respiratory acidosis. Blood perfusion was assessed using the following algorithm: (IELAS minus ICOLL) divided by (INADH minus ICOLL). The intensity ratio linearly decreased with the reduction of blood perfusion. When we totally occluded the artery the ratio decreased tenfold when compared to the ratio of a fully perfused kidney. Results of monitoring blood acidosis by laser-induced fluorescence spectroscopy shows a significant trend between pH and intensity ratio. Since all the slopes were negative, there is an obvious significant correlation between the pH and NADH.COLLAGEN RATIO. Blue-light-induced fluorescence measurements and ratio fluorometry is a sensitive method for monitoring blood perfusion and acidity or alkalinity of an organ.
Fox, Lisa; Walsh, Jane C; Morrison, Todd G; O' Gorman, David; Ruane, Nancy; Mitchell, Caroline; Carey, John J; Coughlan, Robert; McGuire, Brian E
2016-01-01
This study set out to investigate whether cognitive coping strategies that match participants' preferred coping style effectively reduce pain intensity and situational anxiety in a population of people with chronic pain. Chronic pain patients (N = 43) completed questionnaires on coping style, pain intensity, self-efficacy, and situational/trait anxiety. Participants were classified as Monitors (n = 16) or Blunters (n = 19) based on their Miller Behavioural Style Scale score. Participants were then provided with an audiotaped intervention in which they were instructed to focus on pain sensations or to engage in a distraction task and then to rate the pain intensity and their anxiety during and after the attentional focus and distraction conditions. The two interventions were each completed by all participants, having been presented in counterbalanced order. Findings revealed that Monitors' level of anxiety decreased following a congruent (i.e., sensation-focused) intervention. No effects were obtained in terms of perceived pain. For blunters, however, their perceived levels of anxiety and pain did not attenuate following a congruent, distraction-focused intervention. Among persons experiencing chronic pain, tailoring coping strategies to match an individual's preferred coping style--in particular, those with a high level of monitoring--may enhance the benefit of psychological approaches to management of anxiety.
Tulchin-Francis, Kirsten; Stevens, Wilshaw; Jeans, Kelly A
2014-11-01
Assessment of physical, ambulatory, activity using accelerometer-based devices has been reported in healthy individuals across a wide range of ages, as well as in multiple patient populations. Many researchers who utilize the StepWatch Activity Monitor (SAM) rely on the default settings for data collection and analysis. A comparison was made between the standard output from the SAM software, and a novel method to evaluate all walking bouts using an Intensity-Duration-Volume (I-D-V) model in healthy children aged 7-13. 105 children without impairment wore the SAM for a total of 1691 d. Statistically significant differences were seen between 7-8-9 year olds and 10-11-12 year olds using the I-D-V model that were not seen using the standard SAM software default output. The increased sensitivity of this technique could be critical for observing the effect of various interventions on patients who experience physical limitations. This new analytical model also allows researchers to monitor activity and exercise-type behavior in a way which coincides with exercise prescription by assessing intensity, duration and volume of activity bouts.
In-situ Fluorometers Reveal High Frequency Dynamics In Dissolved Organic Matter For Urban Rivers
NASA Astrophysics Data System (ADS)
Croghan, D.; Bradley, C.; Khamis, K.; Hannah, D. M.; Sadler, J. P.; Van Loon, A.
2017-12-01
To-date Dissolved Organic Matter (DOM) dynamics have been quantified poorly in urban rivers, despite the substantial water quality issues linked to urbanisation. Research has been hindered by the low temporal resolution of observations and over-reliance on manual sampling which often fail to capture precipitation events and diurnal dynamics. High frequency data are essential to estimate more accurately DOM fluxes/loads and to understand DOM furnishing and transport processes. Recent advances in optical sensor technology, including field deployable in-situ fluorometers, are yielding new high resolution DOM information. However, no consensus regarding the monitoring resolution required for urban systems exists, with no studies monitoring at <15 min time steps. High-frequency monitoring (5 min resolution; 4 week duration) was conducted on a headwater urban stream in Birmingham, UK (N 52.447430 W -1.936715) to determine the optimum temporal resolution for characterization of DOM event dynamics. A through-flow GGNU-30 monitored wavelengths corresponding to tryptophan-like fluorescence (TLF; Peak T1) (Ex 285 nm/ Em 345 nm) and humic-like fluorescence (HLF; Peak C) (Ex 365 nm/Em 490 nm). The results suggest that at base flow TLF and HLF are relatively stable, though episodic DOM inputs can pulse through the system, which may be missed during lower temporal resolution monitoring. High temporal variation occurs during storm events in TLF and HLF intensity: TLF intensity is highest during the rising limb of the hydrograph and can rapidly decline thereafter, indicating the importance of fast flow-path and close proximity sources to TLF dynamics. HLF intensity tracks discharge more closely, but can also quickly decline during high flow events due to dilution effects. Furthermore, the ratio of TLF:HLF when derived at high-frequency provides a useful indication of the presence and type of organic effluents in stream, which aids in the identification of Combined Sewage Overflow releases. Our work highlights the need for future studies to utilise shorter temporal scales than previously used to monitor urban DOM dynamics. The application of higher frequency monitoring enables the identification of finer-scale patterns and subsequently aids in deciphering the sources and pathways controlling urban DOM dynamics.
Advanced Methods for Aircraft Engine Thrust and Noise Benefits: Nozzle-Inlet Flow Analysis
NASA Technical Reports Server (NTRS)
Gilinsky, Mikhail; Morgan, Morris H.; Povitsky, Alex; Schkolnikov, Natalia; Njoroge, Norman; Coston, Calvin; Blankson, Isaiah M.
2001-01-01
The Fluid Mechanics and Acoustics Laboratory at Hampton University (HU/FM&AL) jointly with the NASA Glenn Research Center has conducted four connected subprojects under the reporting project. Basically, the HU/FM&AL Team has been involved in joint research with the purpose of theoretical explanation of experimental facts and creation of accurate numerical simulation techniques and prediction theory for solution of current problems in propulsion systems of interest to the NAVY and NASA agencies. This work is also supported by joint research between the NASA GRC and the Institute of Mechanics at Moscow State University (IM/MSU) in Russia under a CRDF grant. The research is focused on a wide regime of problems in the propulsion field as well as in experimental testing and theoretical and numerical simulation analyses for advanced aircraft and rocket engines. The FM&AL Team uses analytical methods, numerical simulations and possible experimental tests at the Hampton University campus. The fundamental idea uniting these subprojects is to use nontraditional 3D corrugated and composite nozzle and inlet designs and additional methods for exhaust jet noise reduction without essential thrust loss and even with thrust augmentation. These subprojects are: (1) Aeroperformance and acoustics of Bluebell-shaped and Telescope-shaped designs; (2) An analysis of sharp-edged nozzle exit designs for effective fuel injection into the flow stream in air-breathing engines: triangular-round, diamond-round and other nozzles; (3) Measurement technique improvement for the HU Low Speed Wind Tunnel; a new course in the field of aerodynamics, teaching and training of HU students; experimental tests of Mobius-shaped screws: research and training; (4) Supersonic inlet shape optimization. The main outcomes during this reporting period are: (l) Publications: The AIAA Paper #00-3170 was presented at the 36th AIAA/ASME/SAE/ASEE Joint Propulsion Conference, 17-19 June, 2000, Huntsville, AL. The AIAA Paper #01-1893 has been accepted for the AIAA/NAL-NASDA-ISAS 10th International Space Planes and Hypersonic Systems and Technologies Conference, 24-27 April 2001, Kyoto, Japan. The AIAA Paper #01 -3204 has been accepted for presentation at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference, being held on 08-11 July, in Salt Lake City, UT; (2) A U.S. patent #6,082,635 was granted on July 4, 2000; (3) Grants and proposals: The H U/ FM&AL was awarded the NASA grant NAG-3-2495 in October 2000 and the laboratory is a primary U.S. research team in a joint project under the CRDF award granted to the NASA GRC and IM/MSU (Russia) in July 2000; (4) Theory and numerical simulations: Analytical theory, numerical simulation, comparison of theoretical with experimental results, and modification of theoretical approaches, models, grids, etc., have been conducted for several complicated 2D and 3D nozzle and inlet designs using NASA, ICASE, and IM/MSU codes based on full Euler and Navier-Stokes solvers: CFL3D, FLUENT, and GODUNOV, and others; (5) Experimental Tests: (a) A new course: "Advanced Aerodynamics and Aircraft Performance" presented in spring semester, 2001; training and experimental test research using the HU LSWT. (b) Small-scale M6bius-shaped screws were tested in different conditions and their application has shown essential benefits by comparison with traditional designs; (6) Installation in the FM&AL computer system: second software TECPLOT 8.0 for the UNIX SGI workstation and free TECPLOT 7.5 for the PC Dell computer, and 2D and 3D GRIDGEN (version 9) for the UNIX SGI as well as installation of two free NASA codes, 3D MAG and VULCAN; (7) Student Research Activity: Involvement of two undergraduate students as research assistants in the current research project.
Duffy, G; Regan, F
2017-11-20
The demand for autonomous sensors for unattended, continuous nutrient monitoring in water is rapidly growing with the increasing need for more frequent and widespread environmental pollution monitoring. Legislative bodies, local authorities and industries all require frequent water quality monitoring, however, this is time and labour intensive, and an expensive undertaking. Autonomous sensors allow for frequent, unattended data collection. While this solves the time and labour intensive aspects of water monitoring, sensors can be very expensive. Development of low-cost sensors is essential to realise the concept of Internet of Things (IoT). However there is much work yet to be done in this field. This article reviews current literature on the research and development efforts towards deployable autonomous sensors for phosphorus (in the form of phosphate) and nitrogen (in the form of nitrate), with a focus on analytical performance and cost considerations. Additionally, some recent sensing approaches that could be automated in the future are included, along with an overview of approaches to monitoring both nutrients. These approaches are compared with standard laboratory methods and also with commercially available sensors for both phosphate and nitrate. Application of nutrient sensors in agriculture is discussed as an example of how sensor networks can provide improvements in decision making.
Paksuniemi, M; Sorvoja, H; Alasaarela, E; Myllyla, R
2005-01-01
In the intensive care unit, or during anesthesia, patients are attached to monitors by cables. These cables obstruct nursing staff and hinder the patients from moving freely in the hospital. However, rapidly developing wireless technologies are expected to solve these problems. To this end, this study revealed problem areas in current patient monitoring and established the most important medical parameters to monitor. In addition, usable wireless techniques for short-range data transmission were explored and currently employed wireless applications in the hospital environment were studied. The most important parameters measured of the patient include blood pressures, electrocardiography, respiration rate, heart rate and temperature. Currently used wireless techniques in hospitals are based on the WMTS and WLAN standards. There are no viable solutions for short-range data transmission from patient sensors to patient monitors, but potentially usable techniques in the future are based on the WPAN standards. These techniques include Bluetooth, ZigBee and UWB. Other suitable techniques might be based on capacitive or inductive coupling. The establishing of wireless techniques depends on ensuring the reliability of data transmission, eliminating disturbance by other wireless devices, ensuring patient data security and patient safety, and lowering the power consumption and price.
Open source data logger for low-cost environmental monitoring
2014-01-01
Abstract The increasing transformation of biodiversity into a data-intensive science has seen numerous independent systems linked and aggregated into the current landscape of biodiversity informatics. This paper outlines how we can move forward with this programme, incorporating real time environmental monitoring into our methodology using low-power and low-cost computing platforms. PMID:24855446
NASA Technical Reports Server (NTRS)
Shepherd, C. K.
1989-01-01
Compact transmitters eliminate need for wires to monitors. Biomedical telectrode is small electronic package that attaches to patient in manner similar to small adhesive bandage. Patient wearing biomedical telectrodes moves freely, without risk of breaking or entangling wire connections. Especially beneficial to patients undergoing electrocardiographic monitoring in intensive-care units in hospitals. Eliminates nuisance of coping with wire connections while dressing and going to toilet.
13 CFR 123.3 - How are disaster declarations made?
Code of Federal Regulations, 2010 CFR
2010-01-01
... the disaster occurrence. When a Governor certifies with respect to a drought or to below average water... period meet or exceed the U.S. Drought Monitor (USDM) standard of “severe” (Intensity level D-2 to D-4). The USDM may be found at http://drought.unl.edu/dm/monitor. With respect to below average water levels...
13 CFR 123.3 - How are disaster declarations made?
Code of Federal Regulations, 2014 CFR
2014-01-01
... the disaster occurrence. When a Governor certifies with respect to a drought or to below average water... period meet or exceed the U.S. Drought Monitor (USDM) standard of “severe” (Intensity level D-2 to D-4). The USDM may be found at http://drought.unl.edu/dm/monitor. With respect to below average water levels...
13 CFR 123.3 - How are disaster declarations made?
Code of Federal Regulations, 2011 CFR
2011-01-01
... the disaster occurrence. When a Governor certifies with respect to a drought or to below average water... period meet or exceed the U.S. Drought Monitor (USDM) standard of “severe” (Intensity level D-2 to D-4). The USDM may be found at http://drought.unl.edu/dm/monitor. With respect to below average water levels...
13 CFR 123.3 - How are disaster declarations made?
Code of Federal Regulations, 2013 CFR
2013-01-01
... the disaster occurrence. When a Governor certifies with respect to a drought or to below average water... period meet or exceed the U.S. Drought Monitor (USDM) standard of “severe” (Intensity level D-2 to D-4). The USDM may be found at http://drought.unl.edu/dm/monitor. With respect to below average water levels...
13 CFR 123.3 - How are disaster declarations made?
Code of Federal Regulations, 2012 CFR
2012-01-01
... the disaster occurrence. When a Governor certifies with respect to a drought or to below average water... period meet or exceed the U.S. Drought Monitor (USDM) standard of “severe” (Intensity level D-2 to D-4). The USDM may be found at http://drought.unl.edu/dm/monitor. With respect to below average water levels...
Aerial Detection, Ground Evaluation, and Monitoring of the Southern Pine Beetle: State Perspectives
Ronald F. Billings
2011-01-01
The southern pine beetle (SPB), is recognized as the most serious insect pest of southern pine forests. Outbreaks occur almost every year somewhere within its wide range, requiring intensive suppression efforts to minimize resource losses to Federal, State, and private forests. Effective management involves annual monitoring of SPB populations and aerial detection and...
A Step-by-Step Guide to Tier 2 Behavioral Progress Monitoring
ERIC Educational Resources Information Center
Bruhn, Allison L.; McDaniel, Sara C.; Rila, Ashley; Estrapala, Sara
2018-01-01
Students who are at risk for or show low-intensity behavioral problems may need targeted, Tier 2 interventions. Often, Tier 2 problem-solving teams are charged with monitoring student responsiveness to intervention. This process may be difficult for those who are not trained in data collection and analysis procedures. To aid practitioners in these…
2015-04-01
Light Cycle Sleep, 4-8 hrs Increase mobility Consider ear plugs, sleep aid Treatment NA Dexmedetomidine drip Haloperidol IV Push... Haloperidol IV Push Quetiepine PO/Enteral Notes: CV Monitoring Standard monitoring (Tele, SpO2, RR, NBP) Maximize knowledge Standard ICU
USDA-ARS?s Scientific Manuscript database
Spatio-temporal variability of soil moisture (') is a challenge that remains to be better understood. A trade-off exists between spatial coverage and temporal resolution when using the manual and real-time ' monitoring methods. This restricted the comprehensive and intensive examination of ' dynamic...
Using Heart Rate Monitors in Research on Fitness Levels of Children in Physical Education.
ERIC Educational Resources Information Center
Strand, Brad; Reeder, Steve
1993-01-01
Demonstrates the use of heart rate monitors (HRMs) in fitness research and examines heart rate intensity levels of middle school students while they participated in a variety of physical education activities throughout a school year. Research shows the HRM has considerable potential in assessing fitness achievements in school-age children. (GLR)
USDA-ARS?s Scientific Manuscript database
Stem water potential (SWP) has become a very popular tool for farmers to monitor the water status of almond trees. However, it is labor intensive and time consuming to scale up the measurements in the large field. With the development of unmanned aerial vehicles (UAVs) and sensing payload, it become...
Ekdahl, Jr., Carl A.; Frost, Charles A.
1986-01-01
An intense relativistic electron beam current monitor for a gas neutralized beam transport line includes a first foil for conducting plasma current to the wall where it is measured as it traverses an inductive loop formed by a cavity in the wall. An insulator foil separates the first foil from a second conducting foil which returns the current to the plasma environment.
Ekdahl, C.A. Jr.; Frost, C.A.
1984-11-13
An intense relativistic electron beam current monitor for a gas neutralized beam transport line includes a first foil for conducting plasma current to the wall where it is measured as it traverses an inductive loop formed by a cavity in the wall. An insulator foil separates the first foil from a second conducting foil which returns the current to the plasma environment.
A virtual image chain for perceived image quality of medical display
NASA Astrophysics Data System (ADS)
Marchessoux, Cédric; Jung, Jürgen
2006-03-01
This paper describes a virtual image chain for medical display (project VICTOR: granted in the 5th framework program by European commission). The chain starts from raw data of an image digitizer (CR, DR) or synthetic patterns and covers image enhancement (MUSICA by Agfa) and both display possibilities, hardcopy (film on viewing box) and softcopy (monitor). Key feature of the chain is a complete image wise approach. A first prototype is implemented in an object-oriented software platform. The display chain consists of several modules. Raw images are either taken from scanners (CR-DR) or from a pattern generator, in which characteristics of DR- CR systems are introduced by their MTF and their dose-dependent Poisson noise. The image undergoes image enhancement and comes to display. For soft display, color and monochrome monitors are used in the simulation. The image is down-sampled. The non-linear response of a color monitor is taken into account by the GOG or S-curve model, whereas the Standard Gray-Scale-Display-Function (DICOM) is used for monochrome display. The MTF of the monitor is applied on the image in intensity levels. For hardcopy display, the combination of film, printer, lightbox and viewing condition is modeled. The image is up-sampled and the DICOM-GSDF or a Kanamori Look-Up-Table is applied. An anisotropic model for the MTF of the printer is applied on the image in intensity levels. The density-dependent color (XYZ) of the hardcopy film is introduced by Look-Up-tables. Finally a Human Visual System Model is applied to the intensity images (XYZ in terms of cd/m2) in order to eliminate nonvisible differences. Comparison leads to visible differences, which are quantified by higher order image quality metrics. A specific image viewer is used for the visualization of the intensity image and the visual difference maps.
Carl, M.; Alms, A.; Braun, J.; Dongas, A.; Erb, J.; Goetz, A.; Goepfert, M.; Gogarten, W.; Grosse, J.; Heller, A. R.; Heringlake, M.; Kastrup, M.; Kroener, A.; Loer, S. A.; Marggraf, G.; Markewitz, A.; Reuter, D.; Schmitt, D. V.; Schirmer, U.; Wiesenack, C.; Zwissler, B.; Spies, C.
2010-01-01
Hemodynamic monitoring and adequate volume-therapy, as well as the treatment with positive inotropic drugs and vasopressors are the basic principles of the postoperative intensive care treatment of patient after cardiothoracic surgery. The goal of these S3 guidelines is to evaluate the recommendations in regard to evidence based medicine and to define therapy goals for monitoring and therapy. In context with the clinical situation the evaluation of the different hemodynamic parameters allows the development of a therapeutic concept and the definition of goal criteria to evaluate the effect of treatment. Up to now there are only guidelines for subareas of postoperative treatment of cardiothoracic surgical patients, like the use of a pulmonary artery catheter or the transesophageal echocardiography. The German Society for Thoracic and Cardiovascular Surgery (Deutsche Gesellschaft für Thorax-, Herz- und Gefäßchirurgie, DGTHG) and the German Society for Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin, DGAI) made an approach to ensure and improve the quality of the postoperative intensive care medicine after cardiothoracic surgery by the development of S3 consensus-based treatment guidelines. Goal of this guideline is to assess the available monitoring methods with regard to indication, procedures, predication, limits, contraindications and risks for use. The differentiated therapy of volume-replacement, positive inotropic support and vasoactive drugs, the therapy with vasodilatators, inodilatators and calcium sensitizers and the use of intra-aortic balloon pumps will also be addressed. The guideline has been developed following the recommendations for the development of guidelines by the Association of the Scientific Medical Societies in Germany (AWMF). The presented key messages of the guidelines were approved after two consensus meetings under the moderation of the Association of the Scientific Medical Societies in Germany (AWMF). PMID:20577643
The design of tea garden environmental monitoring system based on WSN
NASA Astrophysics Data System (ADS)
Chen, Huajun; Yuan, Lina
2018-01-01
Through the application of wireless sensor network (WSN) in tea garden, it can realize the change of traditional tea garden to the modern ones, and effectively improves the comprehensive productive capacity of tea garden. According to the requirement of real-time remote in agricultural information collection and monitoring and the power supply affected by environmental limitations, based on WSN, this paper designs a set of tea garden environmental monitoring system, which achieves the monitoring nodes with ad-hoc network as well as automatic acquisition and transmission to the tea plantations of air temperature, light intensity, soil temperature and humidity.
Non-intrusive beam power monitor for high power pulsed or continuous wave lasers
Hawsey, Robert A.; Scudiere, Matthew B.
1993-01-01
A system and method for monitoring the output of a laser is provided in which the output of a photodiode disposed in the cavity of the laser is used to provide a correlated indication of the laser power. The photodiode is disposed out of the laser beam to view the extraneous light generated in the laser cavity whose intensity has been found to be a direct correlation of the laser beam output power level. Further, the system provides means for monitoring the phase of the laser output beam relative to a modulated control signal through the photodiode monitor.
ERIC Educational Resources Information Center
Monk, John S.; And Others
A multiple-group, single-intervention intensive time-series design was used to examine the achievement of an abstract concept, plate tectonics, of students grouped on the basis of cognitive tendency. Two questions were addressed: (1) How do daily achievement patterns differ between formal and concrete cognitive tendency groups when learning an…
Lidar monitoring of regions of intense backscatter with poorly defined boundaries
Vladimir A. Kovalev; Alexander Petkov; Cyle Wold; WeiMin Hao
2011-01-01
The upper height of a region of intense backscatter with a poorly defined boundary between this region and a region of clear air above it is found as the maximal height where aerosol heterogeneity is detectable, that is, where it can be discriminated from noise. The theoretical basis behind the retrieval technique and the corresponding lidar-data-processing procedures...
John Butnor; Brian Roth; Kurt Johnsen
2005-01-01
Tree root systems are commonly evaluated via labor intensive, destructive, time-consuming excavations. Ground-penetrating radar (GPR) can be used to detect and monitor roots if there is sufficient electromagnetic contrast with the surrounding soil matrix. This methodology is commonly used in civil engineering for non-destructive testing of concrete as well as road and...
A Pilot Evaluation of the Reading Intervention 'Own-Voice Intensive Phonics'
ERIC Educational Resources Information Center
Gwernan-Jones, Ruth; Macmillan, Philip; Norwich, Brahm
2018-01-01
This paper describes the mixed methodology evaluation of the Own-Voice Intensive Phonics (OVIP) programme with 33 secondary students with persistent literacy difficulties. The evaluation involved a quasi-experimental evaluation in which 33 students in years 7-9 in four schools used OVIP over an 8 week period and were monitored at three times for…
Differentiating fatty and non-fatty tissue using photoacoustic imaging
NASA Astrophysics Data System (ADS)
Pan, Leo; Rohling, Robert; Abolmaesumi, Purang; Salcudean, Septimiu; Tang, Shuo
2014-03-01
In this paper, we demonstrate a temporal-domain intensity-based photoacoustic imaging method that can differentiate between fatty and non-fatty tissues. PA pressure intensity is partly dependent on the tissue's speed of sound, which increases as temperature increases in non-fatty tissue and decreases in fatty tissue. Therefore, by introducing a temperature change in the tissue and subsequently monitoring the change of the PA intensity, it is possible to distinguish between the two types of tissue. A commercial ultrasound system with a 128-element 5-14 MHz linear array transducer and a tunable ND:YAG laser were used to produce PA images. Ex-vivo bovine fat and porcine liver tissues were precooled to below 10°C and then warmed to room-temperature over ~1 hour period. A thermocouple monitored the temperature rise while PA images were acquired at 0.5°C intervals. The averaged intensity of the illuminated tissue region at each temperature interval was plotted and linearly fitted. Liver samples showed a mean increase of 2.82 %/°C, whereas bovine fat had a mean decrease of 6.24 %/°C. These results demonstrate that this method has the potential to perform tissue differentiation in the temporal-domain.
An odor interaction model of binary odorant mixtures by a partial differential equation method.
Yan, Luchun; Liu, Jiemin; Wang, Guihua; Wu, Chuandong
2014-07-09
A novel odor interaction model was proposed for binary mixtures of benzene and substituted benzenes by a partial differential equation (PDE) method. Based on the measurement method (tangent-intercept method) of partial molar volume, original parameters of corresponding formulas were reasonably displaced by perceptual measures. By these substitutions, it was possible to relate a mixture's odor intensity to the individual odorant's relative odor activity value (OAV). Several binary mixtures of benzene and substituted benzenes were respectively tested to establish the PDE models. The obtained results showed that the PDE model provided an easily interpretable method relating individual components to their joint odor intensity. Besides, both predictive performance and feasibility of the PDE model were proved well through a series of odor intensity matching tests. If combining the PDE model with portable gas detectors or on-line monitoring systems, olfactory evaluation of odor intensity will be achieved by instruments instead of odor assessors. Many disadvantages (e.g., expense on a fixed number of odor assessors) also will be successfully avoided. Thus, the PDE model is predicted to be helpful to the monitoring and management of odor pollutions.
Multi-channel measurement for hetero-core optical fiber sensor by using CMOS camera
NASA Astrophysics Data System (ADS)
Koyama, Yuya; Nishiyama, Michiko; Watanabe, Kazuhiro
2015-07-01
Fiber optic smart structures have been developed over several decades by the recent fiber optic sensor technology. Optical intensity-based sensors, which use LD or LEDs, can be suitable for the monitor system to be simple and cost effective. In this paper, a novel fiber optic smart structure with human-like perception has been demonstrated by using intensity-based hetero-core optical fiber sensors system with the CMOS detector. The optical intensity from the hetero-core optical fiber bend sensor is obtained as luminance spots indicated by the optical power distributions. A number of optical intensity spots are simultaneously readout by taking a picture of luminance pattern. To recognize the state of fiber optic smart structure with the hetero-core optical fibers, the template matching process is employed with Sum of Absolute Differences (SAD). A fiber optic smart glove having five optic fiber nerves have been employed to monitor hand postures. Three kinds of hand postures have been recognized by means of the template matching process. A body posture monitoring has also been developed by placing the wearable hetero-core optical fiber bend sensors on the body segments. In order for the CMOS system to be a human brain-like, the luminescent spots in the obtained picture were arranged to make the pattern corresponding to the position of body segments. As a result, it was successfully demonstrated that the proposed fiber optic smart structure could recognize eight kinds of body postures. The developed system will give a capability of human brain-like processing to the existing fiber optic smart structures.
Analysis of Land Subsidence Monitoring in Mining Area with Time-Series Insar Technology
NASA Astrophysics Data System (ADS)
Sun, N.; Wang, Y. J.
2018-04-01
Time-series InSAR technology has become a popular land subsidence monitoring method in recent years, because of its advantages such as high accuracy, wide area, low expenditure, intensive monitoring points and free from accessibility restrictions. In this paper, we applied two kinds of satellite data, ALOS PALSAR and RADARSAT-2, to get the subsidence monitoring results of the study area in two time periods by time-series InSAR technology. By analyzing the deformation range, rate and amount, the time-series analysis of land subsidence in mining area was realized. The results show that InSAR technology could be used to monitor land subsidence in large area and meet the demand of subsidence monitoring in mining area.
A real-time beam-profile monitor for a PET cyclotron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoehr, C.; Uittenbosch, T.; Verzilov, V.
2012-12-19
Beam profiles in medical cyclotrons are traditionally measured using techniques that do not provide any information about short-term fluctuations of the beam shape or beam intensity. To overcome this, we have developed a real-time harp beam profile monitor which can withstand beam power in excess of 300 W. The monitor and electronics were constructed and applied toward a 13 MeV proton beam with current of up to 25 {mu}A. Herein are reported preliminary beam-profile measurement results.
NASA Technical Reports Server (NTRS)
Alekanyan, T. M.; Dorman, L. I.; Yanke, V. G.; Korotkov, V. K.
1985-01-01
The latitudinal behavior of intensities and multiplicities was registered by the neutron monitor 2 NM and the lead-free neutron monitor 3 SND (slow-neuron detector) in the equator-Kaliningrad line in the Atlantic Ocean. Coupling coefficients for 3 SND show the sensitivity of this detector to primary particles of cosmic rays of energies on the average lower than for 2 NM. As multiplicities increase, the coupling coefficients shift towards higher energies.
A real-time beam-profile monitor for a PET cyclotron
NASA Astrophysics Data System (ADS)
Hoehr, C.; Uittenbosch, T.; Verzilov, V.; English, W.; Buckley, K.; Gray, D.; Kellog, S.; Cameron, D.; Schaffer, P.
2012-12-01
Beam profiles in medical cyclotrons are traditionally measured using techniques that do not provide any information about short-term fluctuations of the beam shape or beam intensity. To overcome this, we have developed a real-time harp beam profile monitor which can withstand beam power in excess of 300 W. The monitor and electronics were constructed and applied toward a 13 MeV proton beam with current of up to 25 μA. Herein are reported preliminary beam-profile measurement results.
Turgut, Altan; Orr, Marshall; Pasewark, Bruce
2007-05-01
Waveguide invariant theory is used to describe the frequency shifts of constant acoustic intensity level curves in broadband signal spectrograms measured at the New Jersey Shelf during the winter of 2003. The broadband signals (270-330 Hz) were transmitted from a fixed source and received at three fixed receivers, located at 10, 20, and 30 km range along a cross-shelf propagation track. The constant acoustic intensity level curves of the received signals indicate regular frequency shifts that can be well predicted by the change in water depth observed through tens of tidal cycles. A second pattern of frequency shifts is observed at only 30 km range where significant variability of slope-water intrusion was measured. An excellent agreement between observed frequency shifts of the constant acoustic intensity levels and those predicted by the change in tide height and slope water elevations suggests the capability of long-term acoustic monitoring of tide and slope water intrusions in winter conditions.
Diffracted light from latent images in photoresist for exposure control
Bishop, Kenneth P.; Brueck, Steven R. J.; Gaspar, Susan M.; Hickman, Kirt C.; McNeil, John R.; Naqvi, S. Sohail H.; Stallard, Brian R.; Tipton, Gary D.
1997-01-01
In microelectronics manufacturing, an arrangement for monitoring and control of exposure of an undeveloped photosensitive layer on a structure susceptible to variations in optical properties in order to attain the desired critical dimension for the pattern to be developed in the photosensitive layer. This is done by ascertaining the intensities for one or more respective orders of diffracted power for an incident beam of radiation corresponding to the desired critical dimension for the photosensitive layer as a function of exposure time and optical properties of the structure, illuminating the photosensitive layer with a beam of radiation of one or more frequencies to which the photosensitive layer is not exposure-sensitive, and monitoring the intensities of the orders of diffracted radiation due to said illumination including at least the first order of diffracted radiation thereof, such that when said predetermined intensities for the diffracted orders are reached during said illumination of photosensitive layer, it is known that a pattern having at least approximately the desired critical dimension can be developed on the photosensitive layer.
A real-time monitoring system for night glare protection
NASA Astrophysics Data System (ADS)
Ma, Jun; Ni, Xuxiang
2010-11-01
When capturing a dark scene with a high bright object, the monitoring camera will be saturated in some regions and the details will be lost in and near these saturated regions because of the glare vision. This work aims at developing a real-time night monitoring system. The system can decrease the influence of the glare vision and gain more details from the ordinary camera when exposing a high-contrast scene like a car with its headlight on during night. The system is made up of spatial light modulator (The liquid crystal on silicon: LCoS), image sensor (CCD), imaging lens and DSP. LCoS, a reflective liquid crystal, can modular the intensity of reflective light at every pixel as a digital device. Through modulation function of LCoS, CCD is exposed with sub-region. With the control of DSP, the light intensity is decreased to minimum in the glare regions, and the light intensity is negative feedback modulated based on PID theory in other regions. So that more details of the object will be imaging on CCD and the glare protection of monitoring system is achieved. In experiments, the feedback is controlled by the embedded system based on TI DM642. Experiments shows: this feedback modulation method not only reduces the glare vision to improve image quality, but also enhances the dynamic range of image. The high-quality and high dynamic range image is real-time captured at 30hz. The modulation depth of LCoS determines how strong the glare can be removed.
Mehrang, Saeed; Pietilä, Julia; Korhonen, Ilkka
2018-02-22
Wrist-worn sensors have better compliance for activity monitoring compared to hip, waist, ankle or chest positions. However, wrist-worn activity monitoring is challenging due to the wide degree of freedom for the hand movements, as well as similarity of hand movements in different activities such as varying intensities of cycling. To strengthen the ability of wrist-worn sensors in detecting human activities more accurately, motion signals can be complemented by physiological signals such as optical heart rate (HR) based on photoplethysmography. In this paper, an activity monitoring framework using an optical HR sensor and a triaxial wrist-worn accelerometer is presented. We investigated a range of daily life activities including sitting, standing, household activities and stationary cycling with two intensities. A random forest (RF) classifier was exploited to detect these activities based on the wrist motions and optical HR. The highest overall accuracy of 89.6 ± 3.9% was achieved with a forest of a size of 64 trees and 13-s signal segments with 90% overlap. Removing the HR-derived features decreased the classification accuracy of high-intensity cycling by almost 7%, but did not affect the classification accuracies of other activities. A feature reduction utilizing the feature importance scores of RF was also carried out and resulted in a shrunken feature set of only 21 features. The overall accuracy of the classification utilizing the shrunken feature set was 89.4 ± 4.2%, which is almost equivalent to the above-mentioned peak overall accuracy.
Marics, Gábor; Koncz, Levente; Eitler, Katalin; Vatai, Barbara; Szénási, Boglárka; Zakariás, David; Mikos, Borbála; Körner, Anna; Tóth-Heyn, Péter
2015-03-19
Continuous glucose monitoring (CGM) originally was developed for diabetic patients and it may be a useful tool for monitoring glucose changes in pediatric intensive care unit (PICU). Its use is, however, limited by the lack of sufficient data on its reliability at insufficient peripheral perfusion. We aimed to correlate the accuracy of CGM with laboratory markers relevant to disturbed tissue perfusion. In 38 pediatric patients (age range, 0-18 years) requiring intensive care we tested the effect of pH, lactate, hematocrit and serum potassium on the difference between CGM and meter glucose measurements. Guardian® (Medtronic®) CGM results were compared to GEM 3000 (Instrumentation laboratory®) and point-of-care measurements. The clinical accuracy of CGM was evaluated by Clarke Error Grid -, Bland-Altman analysis and Pearson's correlation. We used Friedman test for statistical analysis (statistical significance was established as a p < 0.05). CGM values exhibited a considerable variability without any correlation with the examined laboratory parameters. Clarke, Bland-Altman analysis and Pearson's correlation coefficient demonstrated a good clinical accuracy of CGM (zone A and B = 96%; the mean difference between reference and CGM glucose was 1,3 mg/dL, 48 from the 780 calibration pairs overrunning the 2 standard deviation; Pearson's correlation coefficient: 0.83). The accuracy of CGM measurements is independent of laboratory parameters relevant to tissue hypoperfusion. CGM may prove a reliable tool for continuous monitoring of glucose changes in PICUs, not much influenced by tissue perfusion, but still not appropriate for being the base for clinical decisions.
The effects of visitor density and intensity on the behavior of two captive jaguars (Panthera onca).
Sellinger, Rebecca L; Ha, James C
2005-01-01
Several researchers have reported significant effects of visitor density and intensity on captive animal behavior. This study determined whether this was the case for 2 captive jaguars housed at the Woodland Park Zoo, Seattle, WA. Subjects were monitored for changes in behavior as a function of visitor density and intensity. The jaguars were observed for 8 hr per week for 29 weeks--March 31 until October 11, 1998--for a total of 230 hr. Continuous frequency sampling was used, and visitor density and intensity were recorded every minute. Parametric statistics were used to test for correlations between behavior and density, intensity, or a combination of the two. Both density and intensity were significant for time spent non-visible for both cats, and intensity showed a significant effect on the female's pacing behavior. In addition, the male cat exhibited a trend for increased aggression based on both visitor density and intensity and a trend of intensity affecting his social behavior. In conclusion, both density and intensity had a significant effect on behavior, with intensity showing a larger effect.
The Role of Multimodal Invasive Monitoring in Acute Traumatic Brain Injury.
Lazaridis, Christos; Robertson, Claudia S
2016-10-01
This article reviews the role of modalities that directly monitor brain parenchyma in patients with severe traumatic brain injury. The physiology monitored involves compartmental and perfusion pressures, tissue oxygenation and metabolism, quantitative blood flow, pressure autoregulation, and electrophysiology. There are several proposed roles for this multimodality monitoring, such as to track, prevent, and treat the cascade of secondary brain injury; monitor the neurologically injured patient; integrate various data into a composite, patient-specific, and dynamic picture; apply protocolized, pathophysiology-driven intensive care; use as a prognostic marker; and understand pathophysiologic mechanisms involved in secondary brain injury to develop preventive and abortive therapies, and to inform future clinical trials. Copyright © 2016 Elsevier Inc. All rights reserved.
Computer EEG-monitoring of laserotherapy effects in patients with asteno-depressive syndrome.
Omelchenko, V P; Baranchook, I S; Dmitriev, M N
1999-01-01
Nowadays the low-intensive laserotherapy is shown to be an effective and non-hazardous method of asteno-depressive syndrome treatment. The differences of EEG-reactions to laser influences have been revealed in patients of different age groups. And the close negative correlation between the therapy effect, on the one hand, and the patient's age and the disease duration, on the other hand, has been shown. No significant changes of the patient's state or integrative EEG-indices have been evoked by a placebo application. The results showed the advantages of the low-intensive laserotherapy in asteno-depressive syndrome treatment and confirmed the significance of computer EEG-monitoring for prediction, control and correction of the state of the patient.
Bertolini, G; Nattino, G; Langer, M; Tavola, M; Crespi, D; Mondini, M; Rossi, C; Previtali, C; Marshall, J; Poole, D
2016-01-01
The prompt availability of reliable epidemiological information on emerging pandemics is crucial for public health policy-makers. Early in 2013, a possible new H1N1 epidemic notified by an intensive care unit (ICU) to GiViTI, the Italian ICU network, prompted the re-activation of the real-time monitoring system developed during the 2009-2010 pandemic. Based on data from 216 ICUs, we were able to detect and monitor an outbreak of severe H1N1 infection, and to compare the situation with previous years. The timely and correct assessment of the severity of an epidemic can be obtained by investigating ICU admissions, especially when historical comparisons can be made.
Mapping and monitoring of crop intensity, calendar and irrigation using multi-temporal MODIS data
NASA Astrophysics Data System (ADS)
Xiao, X.; Boes, S.; Mulukutla, G.; Proussevitch, A.; Routhier, M.
2005-12-01
Agriculture is the most extensive land use and water use on the Earth. Because of the diverse range of natural environments and human needs, agriculture is also the most complicated land use and water use system, which poses an enormous challenge to the scientific community, the public and decision-makers. Updated and geo-referenced information on crop intensity (number of crops per year), calendar (planting date, harvesting date) and irrigation is critically needed to better understand the impacts of agriculture on biogeochemical cycles (e.g., carbon, nitrogen, trace gases), water and climate dynamics. Here we present an effort to develop a novel approach for mapping and monitoring crop intensity, calendar and irrigation, using multi-temporal Moderate Resolution Imaging Spectroradiometer (MODIS) image data. Our algorithm employed three vegetation indices that are sensitive to the seasonal dynamics of leaf area index, light absorption by leaf chlorophyll and land surface water content. Our objective is to generate geospatial databases of crop intensity, calendar and irrigation at 500-m spatial resolution and at 8-day temporal resolution. In this presentation, we report a preliminary geospatial dataset of paddy rice crop intensity, calendar and irrigation in Asia, which is developed from the 8-day composite images of MODIS in 2002. The resultant dataset could be used in many applications, including hydrological and climate modeling.
Observations and analyses of an intense waves-in-ice event in the Sea of Okhotsk
NASA Astrophysics Data System (ADS)
Marko, John R.
2003-09-01
Ice draft, ice velocity, ice concentration, and current profile data gathered at an array of eight continental shelf monitoring sites east of Sakhalin Island were analyzed in conjunction with regional meteorological data to document and explain intense wave occurrences several hundred kilometers inside the Sea of Okhotsk ice pack. The studied event was associated with the 19-21 March 1998 passage of an intense cyclone, which produced waves with amplitudes in excess of 1 m at the most offshore monitoring location. The relatively monochromatic character of the waves allowed extraction of wave intensity time series from ice draft time series data. Spatial and temporal variations in these data were used to establish directions and speeds of wave energy propagation for comparisons with an earlier interpretation [, 1988] of an Antarctic intense waves-in-ice event. It was concluded that although both events are compatible with a two-stage process in which initially slowly advancing wave activity increases subsequent ice cover wave transmissivity, the first stage of the Sea of Okhotsk event was not explicable in terms of the static stress-induced changes in the waves-in-ice dispersion relationship proposed by Liu and Mollo-Christensen. An alternative explanation is offered that eschews the linkage between wave group velocities and the observed slow rates of wave energy propagation and attributes the subsequent transition to more normal wave propagation behavior to ice pack divergence.
ALOS PALSAR Winter Coherence and Summer Intensities for Large Scale Forest Monitoring in Siberia
NASA Astrophysics Data System (ADS)
Thiel, Christian; Thiel, Carolin; Santoro, Maurizio; Schmullius, Christiane
2008-11-01
In this paper summer intensity and winter coherence images are used for large scale forest monitoring. The intensities (FBD HH/HV) have been acquired during summer 2007 and feature the K&C intensity stripes [1]. The processing consisted of radiometric calibration, orthorectification, and topographic normalisation. The coherence has been estimated from interferometric pairs with 46-days repeat-pass intervals. The pairs have been acquired during the winters 2006/2007 and 2007/2008. During both winters suited weather conditions have been reported. Interferometric processing consisted of SLC co-registration at sub-pixel level, common-band filtering in range and azimuth and generation of a differential interferogram, which was used in the coherence estimation procedure based on adaptive estimation. All images were geocoded using SRTM data. The pixel size of the final SAR products is 50 m x 50 m. It could already be demonstrated, that by using PALSAR intensities and winter coherence forest and non-forest can be clearly separated [2]. By combining both data types hardly any overlap of the class signatures was detected, even though the analysis was conducted on pixel level and no speckle filter has been applied. Thus, the delineation of a forest cover mask could be executed operationally. The major hitch is the definition of a biomass threshold for regrowing forest to be distinguished as forest.
Open-access MIMIC-II database for intensive care research.
Lee, Joon; Scott, Daniel J; Villarroel, Mauricio; Clifford, Gari D; Saeed, Mohammed; Mark, Roger G
2011-01-01
The critical state of intensive care unit (ICU) patients demands close monitoring, and as a result a large volume of multi-parameter data is collected continuously. This represents a unique opportunity for researchers interested in clinical data mining. We sought to foster a more transparent and efficient intensive care research community by building a publicly available ICU database, namely Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II). The data harnessed in MIMIC-II were collected from the ICUs of Beth Israel Deaconess Medical Center from 2001 to 2008 and represent 26,870 adult hospital admissions (version 2.6). MIMIC-II consists of two major components: clinical data and physiological waveforms. The clinical data, which include patient demographics, intravenous medication drip rates, and laboratory test results, were organized into a relational database. The physiological waveforms, including 125 Hz signals recorded at bedside and corresponding vital signs, were stored in an open-source format. MIMIC-II data were also deidentified in order to remove protected health information. Any interested researcher can gain access to MIMIC-II free of charge after signing a data use agreement and completing human subjects training. MIMIC-II can support a wide variety of research studies, ranging from the development of clinical decision support algorithms to retrospective clinical studies. We anticipate that MIMIC-II will be an invaluable resource for intensive care research by stimulating fair comparisons among different studies.
Diamond sensors and polycapillary lenses for X-ray absorption spectroscopy.
Ravel, B; Attenkofer, K; Bohon, J; Muller, E; Smedley, J
2013-10-01
Diamond sensors are evaluated as incident beam monitors for X-ray absorption spectroscopy experiments. These single crystal devices pose a challenge for an energy-scanning experiment using hard X-rays due to the effect of diffraction from the crystalline sensor at energies which meet the Bragg condition. This problem is eliminated by combination with polycapillary lenses. The convergence angle of the beam exiting the lens is large compared to rocking curve widths of the diamond. A ray exiting one capillary from the lens meets the Bragg condition for any reflection at a different energy from the rays exiting adjacent capillaries. This serves to broaden each diffraction peak over a wide energy range, allowing linear measurement of incident intensity over the range of the energy scan. Extended X-ray absorption fine structure data are measured with a combination of a polycapillary lens and a diamond incident beam monitor. These data are of comparable quality to data measured without a lens and with an ionization chamber monitoring the incident beam intensity.
Plastic scintillator block as photon beam monitor for EGRET calibration
NASA Technical Reports Server (NTRS)
Lin, Y. C.; Hofstadter, R.; Nolan, P. L.; Walker, A. H.; Mattox, J. R.; Hughes, E. B.
1991-01-01
The EGRET (Energetic Gamma Ray Experiment Telescope) detector has been calibrated at SLAC (Stanford Linear Accelerator) and, to a lesser degree, at the MIT Bates Linear Accelerator Center. To monitor the photon beams for the calibration, a plastic scintillator block, 5 cm x 5 cm in cross section, 15 cm in length, and viewed by a single photomultiplier tube, was used for the entire beam energy range of 15 MeV to 10 GeV. The design operation, and method of analysis of the beam intensity are presented. A mathematical framework has been developed to treat the general case of a beam with multiphoton beam pulses and with a background component. A procedure to deal with the fluctuations of the beam intensity over a data-taking period was also developed. The photon beam monitor is physically sturdy, electronically steady, simple to construct, and easy to operate. Its major merits lie in its sheer simplicity of construction and operation and in the wide energy range it can cover.
Mechanochromic behavior of a luminescent silicone rubber under tensile deformation
NASA Astrophysics Data System (ADS)
Kim, Yeon Ju; Lee, Sang Hwan; Jeong, Kwang-Un; Nah, Changwoon
2016-09-01
A novel mechanochromic elastomer based on silicone rubber and coumarin 6 dye have been prepared with various concentrations of the dye ranges from 2wt.% to a maximum of 5wt.% by solution mixing technique. After evaporating the solvent, cured samples were prepared as thin films using compression molding at 170° C. The optimum composition of the dye in rubber composites was determined based on the mechanochromic performance characterized with ultraviolet/visible (UV/Vis) spectrometer, x-ray diffraction (XRD) and spectrofluorometer (FL). The UV/Vis spectrometer monitors the dye aggregation in polymer film during the tensile deformation. The XRD monitors the change in size of dye aggregates. The FL monitors the optical response during tensile deformation due to the re-arrangement of dyes. As increasing a mechanical deformation to the polymeric composite film, UV/Vis absorption intensity was decreased and the FL emission wavelength was moved to decrease wavelength because of breaking dye aggregations. Also, XRD intensity peak was decreased, which dye aggregations were broken after mechanical deformation.
NASA Astrophysics Data System (ADS)
Filipponi, Federico; Zucca, Francesco; Taramelli, Andrea; Valentini, Emiliana
2015-12-01
Monitoring sediment fluxes patterns in coastal area, like dispersion, sedimentation and resuspension processes, is a relevant topic for scientists, decision makers and natural resources management. Time series analysis of Earth Observation (EO) data may contribute to the understanding and the monitoring of processes in sedimentary depositional marine environment, especially for shallow coastal areas. This research study show the ability of optical medium resolution imagery to interpret the evolution of sediment resuspension from seafloor in coastal areas during intense wind forcings. Intense bora wind events in northern Adriatic Sea basin during winter season provoke considerable wave-generated resuspension of sediments, which cause variation in water column turbidity. Total Suspended Matter (TSM) product has been selected as proxy for qualitative and quantitative analysis of resuspended sediments. In addition, maximum signal depth (Z90_max), has been used to evaluate the evolution of sediment concentration in the water column.
Plastic Optical Fibre Sensor for Spine Bending Monitoring with Power Fluctuation Compensation
Zawawi, Mohd Anwar; O'Keeffe, Sinead; Lewis, Elfed
2013-01-01
This paper presents the implementation of power fluctuation compensation for an intensity-based optical fibre bending sensor aimed at monitoring human spine bending in a clinical environment. To compensate for the light intensity changes from the sensor light source, a reference signal was provided via the light reflection from an aluminum foil surface fixed at a certain distance from the source fibre end tips. From the results, it was found that the investigated sensor compensation technique was capable of achieving a 2° resolution for a bending angle working range between 0° and 20°. The study also suggested that the output voltage ratio has a 0.55% diversion due to input voltage variation between 2.9 V and 3.4 V and a 0.25% output drift for a 2 h measurement. With the achieved sensor properties, human spine monitoring in a clinical environment can potentially be implemented using this approach with power fluctuation compensation. PMID:24233073
A quality monitor and monitoring technique employing optically stimulated electron emission
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Welch, Christopher S. (Inventor); Joe, Edmond J. (Inventor); Hefner, Bill Bryan, Jr. (Inventor)
1995-01-01
A light source directs ultraviolet light onto a test surface and a detector detects a current of photoelectrons generated by the light. The detector includes a collector which is positively biased with respect to the test surface. Quality is indicated based on the photoelectron current. The collector is then negatively biased to replace charges removed by the measurement of a nonconducting substrate to permit subsequent measurements. Also, the intensity of the ultraviolet light at a particular wavelength is monitored and the voltage of the light source varied to maintain the light a constant desired intensity. The light source is also cooled via a gas circulation system. If the test surface is an insulator, the surface is bombarded with ultraviolet light in the presence of an electron field to remove the majority of negative charges from the surface. The test surface is then exposed to an ion field until it possesses no net charge. The technique described above is then performed to assess quality.
Patient Participation and the Use of Ehealth Tools for Pharmacoviligance.
Berrewaerts, Joëlle; Delbecque, Laure; Orban, Pierre; Desseilles, Martin
2016-01-01
In recent years, pharmacovigilance has undergone some major changes. First, the patient's active role in identifying and describing adverse drug reactions (ADRs) has gained recognition. Second, pharmacovigilance has increasingly incorporated information and communications technology (ICT). Patients can now upload their own reports of ADRs online. Data on intensive medication monitoring are now collected via the Internet and smartphones. Worldwide collection of AEs using smart phones might become the leading technique in Low and Middle Income Countries where broad mobile phone service can be managed cheaper than Internet communication. At the same time, researchers are exploring the potential for data sharing via online forums and Internet search engines. In particular we synthetize the Pros and cons of the various methods for gathering pharmacovigilance data (i.e., Web-based spontaneous reporting of adverse drug reactions; Intensive drug monitoring studies; Analysis of online forum postings; Use of mobile phone systems to monitor drug effects). This article describes these advances and highlights their respective contributions.
Patient Participation and the Use of Ehealth Tools for Pharmacoviligance
Berrewaerts, Joëlle; Delbecque, Laure; Orban, Pierre; Desseilles, Martin
2016-01-01
In recent years, pharmacovigilance has undergone some major changes. First, the patient’s active role in identifying and describing adverse drug reactions (ADRs) has gained recognition. Second, pharmacovigilance has increasingly incorporated information and communications technology (ICT). Patients can now upload their own reports of ADRs online. Data on intensive medication monitoring are now collected via the Internet and smartphones. Worldwide collection of AEs using smart phones might become the leading technique in Low and Middle Income Countries where broad mobile phone service can be managed cheaper than Internet communication. At the same time, researchers are exploring the potential for data sharing via online forums and Internet search engines. In particular we synthetize the Pros and cons of the various methods for gathering pharmacovigilance data (i.e., Web-based spontaneous reporting of adverse drug reactions; Intensive drug monitoring studies; Analysis of online forum postings; Use of mobile phone systems to monitor drug effects). This article describes these advances and highlights their respective contributions. PMID:27148052
Apparatus for monitoring crystal growth
Sachs, Emanual M.
1981-01-01
A system and method are disclosed for monitoring the growth of a crystalline body from a liquid meniscus in a furnace. The system provides an improved human/machine interface so as to reduce operator stress, strain and fatigue while improving the conditions for observation and control of the growing process. The system comprises suitable optics for forming an image of the meniscus and body wherein the image is anamorphic so that the entire meniscus can be viewed with good resolution in both the width and height dimensions. The system also comprises a video display for displaying the anamorphic image. The video display includes means for enhancing the contrast between any two contrasting points in the image. The video display also comprises a signal averager for averaging the intensity of at least one preselected portions of the image. The value of the average intensity, can in turn be utilized to control the growth of the body. The system and method are also capable of observing and monitoring multiple processes.
Method of monitoring crystal growth
Sachs, Emanual M.
1982-01-01
A system and method are disclosed for monitoring the growth of a crystalline body from a liquid meniscus in a furnace. The system provides an improved human/machine interface so as to reduce operator stress, strain and fatigue while improving the conditions for observation and control of the growing process. The system comprises suitable optics for forming an image of the meniscus and body wherein the image is anamorphic so that the entire meniscus can be viewed with good resolution in both the width and height dimensions. The system also comprises a video display for displaying the anamorphic image. The video display includes means for enhancing the contrast between any two contrasting points in the image. The video display also comprises a signal averager for averaging the intensity of at least one preselected portions of the image. The value of the average intensity, can in turn be utilized to control the growth of the body. The system and method are also capable of observing and monitoring multiple processes.
Fiber optic current monitor for high-voltage applications
Renda, G.F.
1992-04-21
A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time. 6 figs.
Fiber optic current monitor for high-voltage applications
Renda, George F.
1992-01-01
A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time.
Moise, Nathalie; Huang, Chen; Rodgers, Anthony; Kohli-Lynch, Ciaran N; Tzong, Keane Y; Coxson, Pamela G; Bibbins-Domingo, Kirsten; Goldman, Lee; Moran, Andrew E
2016-07-01
The population health effect and cost-effectiveness of implementing intensive blood pressure goals in high-cardiovascular disease (CVD) risk adults have not been described. Using the CVD Policy Model, CVD events, treatment costs, quality-adjusted life years, and drug and monitoring costs were simulated over 2016 to 2026 for hypertensive patients aged 35 to 74 years. We projected the effectiveness and costs of hypertension treatment according to the 2003 Joint National Committee (JNC)-7 or 2014 JNC8 guidelines, and then for adults aged ≥50 years, we assessed the cost-effectiveness of adding an intensive goal of systolic blood pressure <120 mm Hg for patients with CVD, chronic kidney disease, or 10-year CVD risk ≥15%. Incremental cost-effectiveness ratios <$50 000 per quality-adjusted life years gained were considered cost-effective. JNC7 strategies treat more patients and are more costly to implement compared with JNC8 strategies. Adding intensive systolic blood pressure goals for high-risk patients prevents an estimated 43 000 and 35 000 annual CVD events incremental to JNC8 and JNC7, respectively. Intensive strategies save costs in men and are cost-effective in women compared with JNC8 alone. At a willingness-to-pay threshold of $50 000 per quality-adjusted life years gained, JNC8+intensive had the highest probability of cost-effectiveness in women (82%) and JNC7+intensive the highest probability of cost-effectiveness in men (100%). Assuming higher drug and monitoring costs, adding intensive goals for high-risk patients remained consistently cost-effective in men, but not always in women. Among patients aged 35 to 74 years, adding intensive blood pressure goals for high-risk groups to current national hypertension treatment guidelines prevents additional CVD deaths while saving costs provided that medication costs are controlled. © 2016 American Heart Association, Inc.
Runoff process in the Miyake-jima Island after Eruption in 2000
NASA Astrophysics Data System (ADS)
Tagata, Satoshi; Itoh, Takahiro; Miyamoto, Kuniaki; Ishizuka, Tadanori
2014-05-01
Hydrological environment in a basin can be changed completely due to volcanic eruption. Huge volume of tephra was yielded due to eruptions in 2000 in the Miyake-jima Island, Japan. Hydrological monitoring was conducted at four observation sites with several hundred m2 in a basin. Those were decided by the distribution of thickness and the grain size of the tephra. Rainfall intensity was measured by a tipping bucket type raingauge and flow discharge was calculated by the over flow depth in a flow gauging weir in the monitoring. However, the runoff rate did not relate to the grain size of tephra and the thickness of tephra deposition, according to measured data of rainfall intensity and runoff discharge. Supposing that if total runoff in one rainfall event is equal to the summation of rainfall over a threshold, the value of the threshold must be the loss rainfall intensity, the value of the threshold corresponds to the infiltration for the rainfall intensity. The relationships between loss rainfall intensity and the antecedent precipitation are calculated using measured rainfall and runoff data in every rainfall event, focusing on that the antecedent precipitation before occurrence of surface runoff approximately corresponds to the water contents under the slope surface. In present study, the results obtained through data analyses are summarized as follows: (1) There are some values for the threshold values, and the loss rainfall intensity approaches to some constant value if the value of the antecedent precipitation increases. The constant value corresponds to the saturated infiltration. (2) The loss rainfall intensity must be vertical unsaturated infiltration, and observed data for water runoff can express that the runoff is given by the excess rainfall intensity more than the loss rainfall intensity. (3) There are two antecedent times for rainfall with several hours and several days, and the saturation ratio before antecedent time at four observation sites can be predicted in the range from sixty to ninety percentages by the water retention curve.
Deriving a GPS Monitoring Time Recommendation for Physical Activity Studies of Adults.
Holliday, Katelyn M; Howard, Annie Green; Emch, Michael; Rodríguez, Daniel A; Rosamond, Wayne D; Evenson, Kelly R
2017-05-01
Determining locations of physical activity (PA) is important for surveillance and intervention development, yet recommendations for using location recording tools like global positioning system (GPS) units are lacking. Specifically, no recommendation exists for the number of days study participants should wear a GPS to reliably estimate PA time spent in locations. This study used data from participants (N = 224, age = 18-85 yr) in five states who concurrently wore an ActiGraph GT1M accelerometer and a Qstarz BT-Q1000X GPS for three consecutive weeks to construct monitoring day recommendations through variance partitioning methods. PA bouts ≥10 min were constructed from accelerometer counts, and the location of GPS points was determined using a hand-coding protocol. Monitoring day recommendations varied by the type of location (e.g., participant homes vs parks) and the intensity of PA bouts considered (low and medium cut point moderate to vigorous PA [MVPA] bouts or high cut point vigorous PA [VPA] bouts). In general, minutes of all PA intensities spent in a given location could be measured with ≥80% reliability using 1-3 d of GPS monitoring for fitness facilities, schools, and footpaths. MVPA bout minutes in parks and roads required longer monitoring periods of 5-12 d. PA in homes and commercial areas required >19 d of monitoring. Twelve days of monitoring was found to reliably estimate minutes in both low and medium threshold MVPA as well as VPA bouts for many important built environment locations that can be targeted to increase PA at the population level. Minutes of PA in the home environment and commercial locations may be best assessed through other means given the lengthy estimated monitoring time required.
A compact multi-channel fluorescence sensor with ambient light suppression
NASA Astrophysics Data System (ADS)
Egly, Dominik; Geörg, Daniel; Rädle, Matthias; Beuermann, Thomas
2012-03-01
A multi-channel fluorescence sensor has been developed for process monitoring and fluorescence diagnostics. It comprises a fiber-optic set-up with an immersion probe and an intensity-modulated high power ultraviolet light-emitting diode as a light source for fluorescence excitation. By applying an electronic lock-in procedure, fluorescence signals are selectively detectable at ambient light levels of 1000 000 times higher intensity. The sensor was designed to be compact, low cost and easily adaptable to a wide field of application. The set-up was used to simultaneously monitor three important metabolic fluorophores: NAD(P)H, flavins and porphyrins during the cultivation of a baker's yeast. Moreover, the accumulation and degradation kinetics of protoporphyrin IX induced by 5-aminolevulinic acid on the skin could be recorded by the sensor. The detection limit for protoporphyrin IX was determined to be 4 × 10-11 mol L-1. The linear signal amplification of the sensor and time courses of fluorescence signals monitored during yeast fermentations were validated using a commercial CCD spectrometer. The robust and flexible set-up of the fiber-optic measurement system promises easy implementation of this non-invasive analytical tool to fluorescence monitoring and diagnostics in R&D and production.
Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, B.; Lee, S.; Westferro, F.
The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beammore » intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.« less
Geng, Xiaonan; Li, Qiang; Tsui, Pohsiang; Wang, Chiaoyin; Liu, Haoli
2013-09-01
To evaluate the reliability of diagnostic ultrasound-based temperature and elasticity imaging during radiofrequency ablation (RFA) through ex vivo experiments. Procine liver samples (n=7) were employed for RFA experiments with exposures of different power intensities (10 and 50w). The RFA process was monitored by a diagnostic ultrasound imager and the information were postoperatively captured for further temperature and elasticity image analysis. Infrared thermometry was concurrently applied to provide temperature change calibration during the RFA process. Results from this study demonstrated that temperature imaging was valid under 10 W RF exposure (r=0.95), but the ablation zone was no longer consistent with the reference infrared temperature distribution under high RF exposures. The elasticity change could well reflect the ablation zone under a 50 W exposure, whereas under low exposures, the thermal lesion could not be well detected due to the limited range of temperature elevation and incomplete tissue necrosis. Diagnostic ultrasound-based temperature and elastography is valid for monitoring thr RFA process. Temperature estimation can well reflect mild-power RF ablation dynamics, whereas the elastic-change estimation can can well predict the tissue necrosis. This study provide advances toward using diagnostic ultrasound to monitor RFA or other thermal-based interventions.
Study of Anti-Neutrino Beam with Muon Monitor in the T2K experiment
NASA Astrophysics Data System (ADS)
Hiraki, Takahiro
The T2K experiment is a long-baseline neutrino oscillation experiment. In 2013, the T2K collaboration observed electron neutrino appearance in a muon neutrino beam at 7.3 sigma significance. One of the next main goals of the T2K experiment is to measure electron anti-neutrino appearance. In June 2014 we took anti-neutrino beam data for the first time. The anti-neutrino beam was obtained by reversing the polarity of horn focusing magnets. To monitor the direction and intensity of the neutrino beam which is produced from the decay of pions and kaons, the muon beam is continuously measured by Muon Monitor (MUMON). To reconstruct the profile of the muon beam, MUMON is equipped with 49 sensors distributed on a plane behind the beam dump. In this report, we show some results of the anti-neutrino beam data taken by monitors including MUMON. In particular, dependence of the muon beam intensity on electric current of the horns, correlation between the proton beam position and the MUMON profile, and beam stability are presented. Comparison between the data and Monte Carlo simulation is also discussed.
The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.
Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel; Zoccali, Carmine
2016-11-07
Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound-guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre- and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at mitigating lung congestion in high-risk patients on hemodialysis. Copyright © 2016 by the American Society of Nephrology.
The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study
Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A.; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel
2016-01-01
Background and objectives Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. Design, setting, participants, & measurements In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound–guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre– and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Results Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Conclusions Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at mitigating lung congestion in high-risk patients on hemodialysis. PMID:27660305
Global biodiversity monitoring: from data sources to essential biodiversity variables
Proenca, Vania; Martin, Laura J.; Pereira, Henrique M.; Fernandez, Miguel; McRae, Louise; Belnap, Jayne; Böhm, Monika; Brummitt, Neil; Garcia-Moreno, Jaime; Gregory, Richard D.; Honrado, Joao P; Jürgens, Norbert; Opige, Michael; Schmeller, Dirk S.; Tiago, Patricia; van Sway, Chris A
2016-01-01
Essential Biodiversity Variables (EBVs) consolidate information from varied biodiversity observation sources. Here we demonstrate the links between data sources, EBVs and indicators and discuss how different sources of biodiversity observations can be harnessed to inform EBVs. We classify sources of primary observations into four types: extensive and intensive monitoring schemes, ecological field studies and satellite remote sensing. We characterize their geographic, taxonomic and temporal coverage. Ecological field studies and intensive monitoring schemes inform a wide range of EBVs, but the former tend to deliver short-term data, while the geographic coverage of the latter is limited. In contrast, extensive monitoring schemes mostly inform the population abundance EBV, but deliver long-term data across an extensive network of sites. Satellite remote sensing is particularly suited to providing information on ecosystem function and structure EBVs. Biases behind data sources may affect the representativeness of global biodiversity datasets. To improve them, researchers must assess data sources and then develop strategies to compensate for identified gaps. We draw on the population abundance dataset informing the Living Planet Index (LPI) to illustrate the effects of data sources on EBV representativeness. We find that long-term monitoring schemes informing the LPI are still scarce outside of Europe and North America and that ecological field studies play a key role in covering that gap. Achieving representative EBV datasets will depend both on the ability to integrate available data, through data harmonization and modeling efforts, and on the establishment of new monitoring programs to address critical data gaps.
Han, Yang; Wang, Shutao; Payen, Thomas; Konofagou, Elisa
2017-01-01
The successful clinical application of High Intensity Focused Ultrasound (HIFU) ablation depends on reliable monitoring of the lesion formation. Harmonic Motion Imaging guided Focused Ultrasound (HMIgFUS) is an ultrasound-based elasticity imaging technique, which monitors HIFU ablation based on the stiffness change of the tissue instead of the echo intensity change in conventional B-mode monitoring, rendering it potentially more sensitive to lesion development. Our group has shown that predicting the lesion location based on the radiation force-excited region is feasible during HMIgFUS. In this study, the feasibility of a fast lesion mapping method is explored to directly monitor the lesion map during HIFU. The HMI lesion map was generated by subtracting the reference HMI image from the present HMI peak-to-peak displacement map to be streamed on the computer display. The dimensions of the HMIgFUS lesions were compared against gross pathology. Excellent agreement was found between the lesion depth (r2 = 0.81, slope = 0.90), width (r2 = 0.85, slope = 1.12) and area (r2 = 0.58, slope = 0.75). In vivo feasibility was assessed in a mouse with a pancreatic tumor. These findings demonstrate that HMIgFUS can successfully map thermal lesion and monitor lesion development in real time in vitro and in vivo. The HMIgFUS technique may therefore constitute a novel clinical tool for HIFU treatment monitoring. PMID:28323638
Téllez, Maria J; Ulkatan, Sedat; Urriza, Javier; Arranz-Arranz, Beatriz; Deletis, Vedran
2016-02-01
To improve the recognition and possibly prevent confounding peripheral activation of the facial nerve caused by leaking transcranial electrical stimulation (TES) current during corticobulbar tract monitoring. We applied a single stimulus and a short train of electrical stimuli directly to the extracranial portion of the facial nerve. We compared the peripherally elicited compound muscle action potential (CMAP) of the facial nerve with the responses elicited by TES during intraoperative monitoring of the corticobulbar tract. A single stimulus applied directly to the facial nerve at subthreshold intensities did not evoke a CMAP, whereas short trains of subthreshold stimuli repeatedly evoked CMAPs. This is due to the phenomenon of sub- or near-threshold super excitability of the cranial nerve. Therefore, the facial responses evoked by short trains TES, when the leaked current reaches the facial nerve at sub- or near-threshold intensity, could lead to false interpretation. Our results revealed a potential pitfall in the current methodology for facial corticobulbar tract monitoring that is due to the activation of the facial nerve by subthreshold trains of stimuli. This study proposes a new criterion to exclude peripheral activation during corticobulbar tract monitoring. The failure to recognize and avoid facial nerve activation due to leaking current in the peripheral portion of the facial nerve during TES decreases the reliability of corticobulbar tract monitoring by increasing the possibility of false interpretation. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Owen, Adam L; Wong, Del P; Dunlop, Gordon; Groussard, Carole; Kebsi, Wiem; Dellal, Alexandre; Morgans, Ryland; Zouhal, Hassane
2016-09-01
Owen, AL, Wong, DP, Dunlop, G, Groussard, C, Kebsi, W, Dellal, A, Morgans, R, and Zouhal, H. High-intensity training and salivary immunoglobulin A responses in professional top-level soccer players: Effect of training intensity. J Strength Cond Res 30(9): 2460-2469, 2016-This study aimed (a) to test the hypothesis that salivary immunoglobulin A (s-IgA) would vary with training intensity sessions (low-intensity [LI] vs. high-intensity sessions [HI]) during a traditional training program divided into 4 training periods and (b) to identify key variables (e.g., GPS data, rating of perceived exertion [RPE], and training duration), which could affect s-IgA. Saliva samples of 10 elite professional soccer players were collected (a) before the investigation started to establish the baseline level and (b) before and after each 4 training sessions (LI vs. HI). Training intensity was monitored as internal (through heart rate responses and RPE) and external (through GPS) loads. High-intensity sessions were associated with higher external load (GPS) and with higher RPE. Baseline and pretraining s-IgA did not differ between the 4 training sessions both for HI and LI. Post-training s-IgA were not different (in absolute value and in percentage of change) between HI and LI sessions at the first 3 periods. However, at the fourth period, s-IgA concentration for HI session was significantly lower (p ≤ 0.05) than the LI session. The percentage change between s-IgA post-training and s-IgA baseline concentrations differ significantly (p ≤ 0.05) between HI and LI training sessions. Significant correlations between s-IgA and training intensity were also noted. High-intensity soccer training sessions might cause a significant decrease in s-IgA values during the postexercise window as compared with LI sessions. This study encourages coaches to monitor s-IgA in routine, particularly during HI training periods, to take precautions to avoid upper respiratory tract infection in highly trained soccer players.
Bajgain, Rajen; Xiao, Xiangming; Basara, Jeffrey; Wagle, Pradeep; Zhou, Yuting; Zhang, Yao; Mahan, Hayden
2017-02-01
Agricultural drought, a common phenomenon in most parts of the world, is one of the most challenging natural hazards to monitor effectively. Land surface water index (LSWI), calculated as a normalized ratio between near infrared (NIR) and short-wave infrared (SWIR), is sensitive to vegetation and soil water content. This study examined the potential of a LSWI-based, drought-monitoring algorithm to assess summer drought over 113 Oklahoma Mesonet stations comprising various land cover and soil types in Oklahoma. Drought duration in a year was determined by the number of days with LSWI <0 (DNLSWI) during summer months (June-August). Summer rainfall anomalies and LSWI anomalies followed a similar seasonal dynamics and showed strong correlations (r 2 = 0.62-0.73) during drought years (2001, 2006, 2011, and 2012). The DNLSWI tracked the east-west gradient of summer rainfall in Oklahoma. Drought intensity increased with increasing duration of DNLSWI, and the intensity increased rapidly when DNLSWI was more than 48 days. The comparison between LSWI and the US Drought Monitor (USDM) showed a strong linear negative relationship; i.e., higher drought intensity tends to have lower LSWI values and vice versa. However, the agreement between LSWI-based algorithm and USDM indicators varied substantially from 32 % (D 2 class, moderate drought) to 77 % (0 and D 0 class, no drought) for different drought intensity classes and varied from ∼30 % (western Oklahoma) to >80 % (eastern Oklahoma) across regions. Our results illustrated that drought intensity thresholds can be established by counting DNLSWI (in days) and used as a simple complementary tool in several drought applications for semi-arid and semi-humid regions of Oklahoma. However, larger discrepancies between USDM and the LSWI-based algorithm in arid regions of western Oklahoma suggest the requirement of further adjustment in the algorithm for its application in arid regions.
NASA Astrophysics Data System (ADS)
Lee, S. S.; Kim, H. J.; Kim, M. O.; Lee, K.; Lee, K. K.
2016-12-01
A study finding evidence of remediation represented on monitoring data before and after in site intensive remedial action was performed with various quantitative evaluation methods such as mass discharge analysis, tracer data, statistical trend analysis, and analytical solutions at DNAPL contaminated site, Wonju, Korea. Remediation technologies such as soil vapor extraction, soil flushing, biostimulation, and pump-and-treat have been applied to eliminate the contaminant sources of trichloroethylene (TCE) and to prevent the migration of TCE plume from remediation target zones. Prior to the remediation action, the concentration and mass discharges of TCE at all transects were affected by seasonal recharge variation and residual DNAPLs sources. After the remediation, the effect of remediation took place clearly at the main source zone and industrial complex. By tracing a time-series of plume evolution, a greater variation in the TCE concentrations was detected at the plumes near the source zones compared to the relatively stable plumes in the downstream. The removal amount of the residual source mass during the intensive remedial action was estimated to evaluate the efficiency of the intensive remedial action using analytical solution. From results of quantitative evaluation using analytical solution, it is assessed that the intensive remedial action had effectively performed with removal efficiency of 70% for the residual source mass during the remediation period. Analytical solution which can consider and quantify the impacts of partial mass reduction have been proven to be useful tools for quantifying unknown contaminant source mass and verifying dissolved concentration at the DNAPL contaminated site and evaluating the efficiency of remediation using long-term monitoring data. Acknowledgement : This subject was supported by the Korea Ministry of Environment under "GAIA project (173-092-009) and (201400540010)", R&D Project on Enviornmental Management of Geologic CO2 storage" from the KEITI (Project number:2014001810003).
Acharya, Sushama D; Elci, Okan U; Sereika, Susan M; Music, Edvin; Styn, Mindi A; Turk, Melanie Warziski; Burke, Lora E
2009-01-01
Objectives: To describe participants’ adherence to multiple components (attendance, energy intake, fat gram, exercise goals, and self-monitoring eating and exercise behaviors) of a standard behavioral treatment program (SBT) for weight loss and how adherence to these components may influence weight loss and biomarkers (triglycerides, low density lipoproteins [LDL], high density lipoprotein, and insulin) during the intensive and less-intensive intervention phases. Methods: A secondary analysis of a randomized clinical trial consisting of a SBT with either fat-restricted standard or lacto-ovo vegetarian diet. The 12-month intervention was delivered in 33 group sessions. The first six months reflected the intensive phase; the second six months, the less-intensive intervention phase. We conducted the analysis without regard to treatment assignment. Eligible participants included overweight/obese adults (N = 176; mean body mass index = 34.0 kg/m2). The sample was 86.9% female, 70.5% White, and 44.4 ± 8.6 years old. The outcome measures included weight and biomarkers. Results: There was a significant decline in adherence to each treatment component over time (P < 0.0001). In the first six months, adherence to attendance, self-monitoring and the energy goal were significantly associated with greater weight loss (P < 0.05). Adherence to attendance and exercise remained significantly associated with weight loss in the second six months (P < 0.05). Adherence to attendance, self-monitoring and exercise had indirect effects through weight loss on LDL, triglycerides, and insulin (P < 0.05). Conclusions: We observed a decline in adherence to each treatment component as the intervention intensity was reduced. Adherence to multiple treatment components was associated with greater weight loss and improvements in biomarkers. Future research needs to focus on improving and maintaining adherence to all components of the treatment protocol to promote weight loss and maintenance. PMID:19936157
2015-01-01
Background Recent advances in information and communication technology have prompted development of Web-based health tools to promote physical activity, the key component of cardiac rehabilitation and chronic disease management. Mobile apps can facilitate behavioral changes and help in exercise monitoring, although actual training usually takes place away from the point of care in specialized gyms or outdoors. Daily participation in conventional physical activities is expensive, time consuming, and mostly relies on self-management abilities of patients who are typically aged, overweight, and unfit. Facilitation of sustained exercise training at the point of care might improve patient engagement in cardiac rehabilitation. Objective In this study we aimed to test the feasibility of execution and automatic monitoring of several exercise regimens on-site using a Web-enabled leg training system. Methods The MedExercise leg rehabilitation machine was equipped with wireless temperature sensors in order to monitor its usage by the rise of temperature in the resistance unit (Δt°). Personal electronic devices such as laptop computers were fitted with wireless gateways and relevant software was installed to monitor the usage of training machines. Cloud-based software allowed monitoring of participant training over the Internet. Seven healthy participants applied the system at various locations with training protocols typically used in cardiac rehabilitation. The heart rates were measured by fingertip pulse oximeters. Results Exercising in home chairs, in bed, and under an office desk was made feasible and resulted in an intensity-dependent increase of participants’ heart rates and Δt° in training machine temperatures. Participants self-controlled their activities on smart devices, while a supervisor monitored them over the Internet. Individual Δt° reached during 30 minutes of moderate-intensity continuous training averaged 7.8°C (SD 1.6). These Δt° were used as personalized daily doses of exercise with automatic email alerts sent upon achieving them. During 1-week training at home, automatic notifications were received on 4.4 days (SD 1.8). Although the high intensity interval training regimen was feasible on-site, it was difficult for self- and remote management. Opportunistic leg exercise under the desk, while working with a computer, and training in bed while viewing television were less intensive than dosed exercise bouts, but allowed prolonged leg mobilization of 73.7 minutes/day (SD 29.7). Conclusions This study demonstrated the feasibility of self-control exercise training on-site, which was accompanied by online monitoring, electronic recording, personalization of exercise doses, and automatic reporting of adherence. The results suggest that this technology and its applications are useful for the delivery of Web-based exercise rehabilitation and cardiac training programs at the point of care. PMID:28582243
Assessment of multiple DWI offender restrictions
DOT National Transportation Integrated Search
1989-12-01
This report discusses nine new approaches for reducing recidivism among multiple DWI offenders: dedicated detention facilities, diversion programs, electronic monitoring, ignition interlock systems, intensive probation supervision, publishing offende...
NASA Technical Reports Server (NTRS)
2000-01-01
The MyoMonitor EMG system was developed by Delsys, Inc. under SBIR funding from Johnson Space Center. It is a wearable four-channel device that can monitor muscle performance. Presently, its application include rehabilitative therapy, injury prevention, sports medicine, exercise training, and various other muscle monitoring activities. The MyoMonitor uses a two-bar single differential electrode. Due to the electrode-skin interface in traditional EMG equipment, during rigorous muscular activity, the movement of the skin causes the electrode detection surfaces to become compromised. The MyoMonitor eliminates this problem, enabling a wide array of applications and experiments during intense muscular activity. The ability to make such recordings, for example, enables novel experiments aboard the International Space Station for investigating the effect of microgravity on muscle performance. Product still commercially available as of March 2002.
Simple Ultraviolet Short-Pulse Intensity Diagnostic Method Using Atmosphere
NASA Astrophysics Data System (ADS)
Aota, Tatsuya; Takahashi, Eiichi; Losev, Leonid L.; Tabuchi, Takeyuki; Kato, Susumu; Matsumoto, Yuji; Okuda, Isao; Owadano, Yoshiro
2005-05-01
An ultraviolet (UV) short-pulse intensity diagnostic method using atmosphere as a nonlinear medium was developed. This diagnostic method is based on evaluating the ion charge of the two-photon ionization of atmospheric oxygen upon irradiation with a UV (238-299 nm) short-pulse laser. The observed ion signal increased proportionally to the input intensity to the power of ˜2.2, during the two-photon ionization of atmospheric oxygen. An autocorrelator was constructed and used to successfully measure a UV laser pulse of ˜400 fs duration. Since this diagnostic system is used in the open-air under windowless conditions, it can be set along the beam path and used as a UV intensity monitor.
Analysing a cycling grand tour: Can we monitor fatigue with intensity or load ratios?
Sanders, Dajo; Heijboer, Mathieu; Hesselink, Matthijs K C; Myers, Tony; Akubat, Ibrahim
2018-06-01
This study evaluated the changes in ratios of different intensity (rating of perceived exertion; RPE, heart rate; HR, power output; PO) and load measures (session-RPE; sRPE, individualized TRIMP; iTRIMP, Training Stress Score™; TSS) in professional cyclists. RPE, PO and HR data was collected from twelve professional cyclists (VO 2max 75 ± 6 ml∙min∙kg -1 ) during a two-week baseline training period and during two cycling Grand Tours. Subjective:objective intensity (RPE:HR, RPE:PO) and load (sRPE:iTRIMP, sRPE:TSS) ratios and external:internal intensity (PO:HR) and load (TSS:iTRIMP) ratios were calculated for every session. Moderate to large increases in the RPE:HR, RPE:PO and sRPE:TSS ratios (d = 0.79-1.79) and small increases in the PO:HR and sRPE:iTRIMP ratio (d = 0.21-0.41) were observed during Grand Tours compared to baseline training data. Differences in the TSS:iTRIMP ratio were trivial to small (d = 0.03-0.27). Small to moderate week-to-week changes (d = 0.21-0.63) in the PO:HR, RPE:PO, RPE:HR, TSS:iTRIMP, sRPE:iTRIMP and sRPE:TSS were observed during the Grand Tour. Concluding, this study shows the value of using ratios of intensity and load measures in monitoring cyclists. Increases in ratios could reflect progressive fatigue that is not readily detected by changes in solitary intensity/load measures.
Alaverdashvili, Mariam; Paterson, Phyllis G.; Bradley, Michael P.
2015-01-01
Background The rat photothrombotic stroke model can induce brain infarcts with reasonable biological variability. Nevertheless, we observed unexplained high inter-individual variability despite using a rigorous protocol. Of the three major determinants of infarct volume, photosensitive dye concentration and illumination period were strictly controlled, whereas undetected fluctuation in laser power output was suspected to account for the variability. New method The frequently utilized Diode Pumped Solid State (DPSS) lasers emitting 532 nm (green) light can exhibit fluctuations in output power due to temperature and input power alterations. The polarization properties of the Nd:YAG and Nd:YVO4 crystals commonly used in these lasers are another potential source of fluctuation, since one means of controlling output power uses a polarizer with a variable transmission axis. Thus, the properties of DPSS lasers and the relationship between power output and infarct size were explored. Results DPSS laser beam intensity showed considerable variation. Either a polarizer or a variable neutral density filter allowed adjustment of a polarized laser beam to the desired intensity. When the beam was unpolarized, the experimenter was restricted to using a variable neutral density filter. Comparison with existing method(s) Our refined approach includes continuous monitoring of DPSS laser intensity via beam sampling using a pellicle beamsplitter and photodiode sensor. This guarantees the desired beam intensity at the targeted brain area during stroke induction, with the intensity controlled either through a polarizer or variable neutral density filter. Conclusions Continuous monitoring and control of laser beam intensity is critical for ensuring consistent infarct size. PMID:25840363
Xing, Jinyan; Sun, Yunbo; Jie, Yaqi; Yuan, Zhiyong; Liu, Wenjuan
2017-09-01
The purpose of this study is to assess the knowledge, attitudes, and managements regarding delirium of intensive care nurses and physicans, and to assess the perceived barriers related to intensive care unit (ICU) delirium monitoring in China. A descriptive survey was distributed to 1156 critical care nurses and physicians from 74 tertiary and secondary hospitals across Shandong province, China. The overall response rate was 86.18% (n = 917). The majority of respondents (88%) believed that deirium was associated with prolonged mechanical ventilation, and 79.72% thought delirium was associated with prolonged length of hospitalization. Only 14.17% of respondents believed that delirium was common in the ICU setting. Only 25.62% of the respondents reported routine screening of ICU delirium, and only 15.81% utilized Confusion Assessment Method for Intensive Care Unit screening tools. "Lack of appropriate screening tools" and "time restraints" were the most common perceived barriers. 45.4% of the participants had never received any education on ICU delirium. In conclusion, most nurses and physicians consider ICU delirium to be a serious problem, but lack knowledge on delirium and monitor this condition poorly. The survey infers a disconnection between the perceived significance and current monitoring of ICU delirium. There is a critical unmet need for in-service education on ICU delirium for physicians and nurses in China.
Perceptions, attitudes, and current practices regards delirium in China
Xing, Jinyan; Sun, Yunbo; Jie, Yaqi; Yuan, Zhiyong; Liu, Wenjuan
2017-01-01
Abstract The purpose of this study is to assess the knowledge, attitudes, and managements regarding delirium of intensive care nurses and physicans, and to assess the perceived barriers related to intensive care unit (ICU) delirium monitoring in China. A descriptive survey was distributed to 1156 critical care nurses and physicians from 74 tertiary and secondary hospitals across Shandong province, China. The overall response rate was 86.18% (n = 917). The majority of respondents (88%) believed that deirium was associated with prolonged mechanical ventilation, and 79.72% thought delirium was associated with prolonged length of hospitalization. Only 14.17% of respondents believed that delirium was common in the ICU setting. Only 25.62% of the respondents reported routine screening of ICU delirium, and only 15.81% utilized Confusion Assessment Method for Intensive Care Unit screening tools. “Lack of appropriate screening tools” and “time restraints” were the most common perceived barriers. 45.4% of the participants had never received any education on ICU delirium. In conclusion, most nurses and physicians consider ICU delirium to be a serious problem, but lack knowledge on delirium and monitor this condition poorly. The survey infers a disconnection between the perceived significance and current monitoring of ICU delirium. There is a critical unmet need for in-service education on ICU delirium for physicians and nurses in China. PMID:28953621
Clinical dashboards: impact on workflow, care quality, and patient safety.
Egan, Marie
2006-01-01
There is a vast array of technical data that is continuously generated within the intensive care unit environment. In addition to physiological monitors, there is information being captured by the ventilator, intravenous infusion pumps, medication dispensing units, and even the patient's bed. The ability to retrieve and synchronize data is essential for both clinical documentation and real-time problem solving for individual patients and the intensive care unit population as a whole. Technical advances that permit the integration of all relevant data into a singular display or "dashboard" may improve staff efficiency, accelerate decisions, streamline workflow processes, and reduce oversights and errors in clinical practice. Critical care nurses must coordinate all aspects of care for one or more patients. Clinical data are constantly being retrieved, documented, analyzed, and communicated to others, all within the daily routine of nursing care. In addition, many bedside monitors and devices have alarms systems that must be evaluated throughout the workday, and actions taken on the basis of the patient's condition and other data. It is obvious that the complexity within such care processes presents many potential opportunities for overlooking important details. The capability to systematically and logically link physiological monitors and other selected data sets into a cohesive dashboard system holds tremendous promise for improving care quality, patient safety, and clinical outcomes in the intensive care unit.
NASA Astrophysics Data System (ADS)
Huang, Yimei; Lui, Harvey; Zhao, Jianhua; McLean, David I.; Zeng, Haishan
2016-02-01
Photothermolysis induced by femtosecond (fs) lasers may be a promising modality in dermatology because of its advantages of high precision due to multiphoton absorption and deeper penetration due to the use of near infrared wavelengths. Although multiphoton absorption nonlinear effects are capable of precision targeting, the femtosecond laser photothermolysis could still have effects beyond the targeted area if a sufficiently high dose of laser light is used. Such unintended effects could be minimized by real time monitoring photothermolysis during the treatment. Targeted photothermolytic treatment of ex vivo mouse skin dermis was performed with tightly focused fs laser beams. Images of reflectance confocal microscopy (RCM), second harmonic generation (SHG), and two-photon fluorescence (TPF) of the mouse skins were obtained with integrated multimodal microscopy before, during, and after the laser treatment. The RCM, SHG, and TPF signal intensities of the treatment areas changed after high power femtosecond laser irradiation. The intensities of the RCM and SHG signals decreased when the tissue was damaged, while the intensity of the TPF signal increased when the photothermolysis was achieved. Moreover, the TPF signal was more susceptible to the degree of the photothermolysis than the RCM and SHG signals. The results suggested that multimodal microscopy is a potentially useful tool to monitor and assess the femtosecond laser treatment of the skin to achieve microscopic photothermolysis with high precision.
Indirect monitoring shot-to-shot shock waves strength reproducibility during pump-probe experiments
NASA Astrophysics Data System (ADS)
Pikuz, T. A.; Faenov, A. Ya.; Ozaki, N.; Hartley, N. J.; Albertazzi, B.; Matsuoka, T.; Takahashi, K.; Habara, H.; Tange, Y.; Matsuyama, S.; Yamauchi, K.; Ochante, R.; Sueda, K.; Sakata, O.; Sekine, T.; Sato, T.; Umeda, Y.; Inubushi, Y.; Yabuuchi, T.; Togashi, T.; Katayama, T.; Yabashi, M.; Harmand, M.; Morard, G.; Koenig, M.; Zhakhovsky, V.; Inogamov, N.; Safronova, A. S.; Stafford, A.; Skobelev, I. Yu.; Pikuz, S. A.; Okuchi, T.; Seto, Y.; Tanaka, K. A.; Ishikawa, T.; Kodama, R.
2016-07-01
We present an indirect method of estimating the strength of a shock wave, allowing on line monitoring of its reproducibility in each laser shot. This method is based on a shot-to-shot measurement of the X-ray emission from the ablated plasma by a high resolution, spatially resolved focusing spectrometer. An optical pump laser with energy of 1.0 J and pulse duration of ˜660 ps was used to irradiate solid targets or foils with various thicknesses containing Oxygen, Aluminum, Iron, and Tantalum. The high sensitivity and resolving power of the X-ray spectrometer allowed spectra to be obtained on each laser shot and to control fluctuations of the spectral intensity emitted by different plasmas with an accuracy of ˜2%, implying an accuracy in the derived electron plasma temperature of 5%-10% in pump-probe high energy density science experiments. At nano- and sub-nanosecond duration of laser pulse with relatively low laser intensities and ratio Z/A ˜ 0.5, the electron temperature follows Te ˜ Ilas2/3. Thus, measurements of the electron plasma temperature allow indirect estimation of the laser flux on the target and control its shot-to-shot fluctuation. Knowing the laser flux intensity and its fluctuation gives us the possibility of monitoring shot-to-shot reproducibility of shock wave strength generation with high accuracy.
Evaluating the efficiency of environmental monitoring programs
Levine, Carrie R.; Yanai, Ruth D.; Lampman, Gregory G.; Burns, Douglas A.; Driscoll, Charles T.; Lawrence, Gregory B.; Lynch, Jason; Schoch, Nina
2014-01-01
Statistical uncertainty analyses can be used to improve the efficiency of environmental monitoring, allowing sampling designs to maximize information gained relative to resources required for data collection and analysis. In this paper, we illustrate four methods of data analysis appropriate to four types of environmental monitoring designs. To analyze a long-term record from a single site, we applied a general linear model to weekly stream chemistry data at Biscuit Brook, NY, to simulate the effects of reducing sampling effort and to evaluate statistical confidence in the detection of change over time. To illustrate a detectable difference analysis, we analyzed a one-time survey of mercury concentrations in loon tissues in lakes in the Adirondack Park, NY, demonstrating the effects of sampling intensity on statistical power and the selection of a resampling interval. To illustrate a bootstrapping method, we analyzed the plot-level sampling intensity of forest inventory at the Hubbard Brook Experimental Forest, NH, to quantify the sampling regime needed to achieve a desired confidence interval. Finally, to analyze time-series data from multiple sites, we assessed the number of lakes and the number of samples per year needed to monitor change over time in Adirondack lake chemistry using a repeated-measures mixed-effects model. Evaluations of time series and synoptic long-term monitoring data can help determine whether sampling should be re-allocated in space or time to optimize the use of financial and human resources.
Matam, B Rajeswari; Duncan, Heather
2018-06-01
Most existing, expert monitoring systems do not provide the real time continuous analysis of the monitored physiological data that is necessary to detect transient or combined vital sign indicators nor do they provide long term storage of the data for retrospective analyses. In this paper we examine the feasibility of implementing a long term data storage system which has the ability to incorporate real-time data analytics, the system design, report the main technical issues encountered, the solutions implemented and the statistics of the data recorded. McLaren Electronic Systems expertise used to continually monitor and analyse the data from F1 racing cars in real time was utilised to implement a similar real-time data recording platform system adapted with real time analytics to suit the requirements of the intensive care environment. We encountered many technical (hardware and software) implementation challenges. However there were many advantages of the system once it was operational. They include: (1) The ability to store the data for long periods of time enabling access to historical physiological data. (2) The ability to alter the time axis to contract or expand periods of interest. (3) The ability to store and review ECG morphology retrospectively. (4) Detailed post event (cardiac/respiratory arrest or other clinically significant deteriorations in patients) data can be reviewed clinically as opposed to trend data providing valuable clinical insight. Informed mortality and morbidity reviews can be conducted. (5) Storage of waveform data capture to use for algorithm development for adaptive early warning systems. Recording data from bed-side monitors in intensive care/wards is feasible. It is possible to set up real time data recording and long term storage systems. These systems in future can be improved with additional patient specific metrics which predict the status of a patient thus paving the way for real time predictive monitoring.
NASA Astrophysics Data System (ADS)
Fang, Li; Xu, Yusheng; Yao, Wei; Stilla, Uwe
2016-11-01
For monitoring of glacier surface motion in pole and alpine areas, radar remote sensing is becoming a popular technology accounting for its specific advantages of being independent of weather conditions and sunlight. In this paper we propose a method for glacier surface motion monitoring using phase correlation (PC) based on point-like features (PLF). We carry out experiments using repeat-pass TerraSAR X-band (TSX) and Sentinel-1 C-band (S1C) intensity images of the Taku glacier in Juneau icefield located in southeast Alaska. The intensity imagery is first filtered by an improved adaptive refined Lee filter while the effect of topographic reliefs is removed via SRTM-X DEM. Then, a robust phase correlation algorithm based on singular value decomposition (SVD) and an improved random sample consensus (RANSAC) algorithm is applied to sequential PLF pairs generated by correlation using a 2D sinc function template. The approaches for glacier monitoring are validated by both simulated SAR data and real SAR data from two satellites. The results obtained from these three test datasets confirm the superiority of the proposed approach compared to standard correlation-like methods. By the use of the proposed adaptive refined Lee filter, we achieve a good balance between the suppression of noise and the preservation of local image textures. The presented phase correlation algorithm shows the accuracy of better than 0.25 pixels, when conducting matching tests using simulated SAR intensity images with strong noise. Quantitative 3D motions and velocities of the investigated Taku glacier during a repeat-pass period are obtained, which allows a comprehensive and reliable analysis for the investigation of large-scale glacier surface dynamics.
Kim, Jae-Hun; Ha, Tae Lin; Im, Geun Ho; Yang, Jehoon; Seo, Sang Won; Chung, Julius Juhyun; Chae, Sun Young; Lee, In Su; Lee, Jung Hee
2014-03-05
In this study, we have shown the potential of a voxel-based analysis for imaging amyloid plaques and its utility in monitoring therapeutic response in Alzheimer's disease (AD) mice using manganese oxide nanoparticles conjugated with an antibody of Aβ1-40 peptide (HMON-abAβ40). T1-weighted MR brain images of a drug-treated AD group (n=7), a nontreated AD group (n=7), and a wild-type group (n=7) were acquired using a 7.0 T MRI system before (D-1), 24-h (D+1) after, and 72-h (D+3) after injection with an HMON-abAβ40 contrast agent. For the treatment of AD mice, DAPT was injected intramuscularly into AD transgenic mice (50 mg/kg of body weight). For voxel-based analysis, the skull-stripped mouse brain images were spatially normalized, and these voxels' intensities were corrected to reduce voxel intensity differences across scans in different mice. Statistical analysis showed higher normalized MR signal intensity in the frontal cortex and hippocampus of AD mice over wild-type mice on D+1 and D+3 (P<0.01, uncorrected for multiple comparisons). After the treatment of AD mice, the normalized MR signal intensity in the frontal cortex and hippocampus decreased significantly in comparison with nontreated AD mice on D+1 and D+3 (P<0.01, uncorrected for multiple comparisons). These results were confirmed by histological analysis using a thioflavin staining. This unique strategy allows us to detect brain regions that are subjected to amyloid plaque deposition and has the potential for human applications in monitoring therapeutic response for drug development in AD.
Voice amplification as a means of reducing vocal load for elementary music teachers.
Morrow, Sharon L; Connor, Nadine P
2011-07-01
Music teachers are over four times more likely than classroom teachers to develop voice disorders and greater than eight times more likely to have voice-related problems than the general public. Research has shown that individual voice-use parameters of phonation time, fundamental frequency and vocal intensity, as well as vocal load as calculated by cycle dose and distance dose are significantly higher for music teachers than their classroom teacher counterparts. Finding effective and inexpensive prophylactic measures to decrease vocal load for music teachers is an important aspect for voice preservation for this group of professional voice users. The purpose of this study was to determine the effects of voice amplification on vocal intensity and vocal load in the workplace as measured using a KayPENTAX Ambulatory Phonation Monitor (APM) (KayPENTAX, Lincoln Park, NJ). Seven music teachers were monitored for 1 workweek using an APM to determine average vocal intensity (dB sound pressure level [SPL]) and vocal load as calculated by cycle dose and distance dose. Participants were monitored a second week while using a voice amplification unit (Asyst ChatterVox; Asyst Communications Company, Inc., Indian Creek, IL). Significant decreases in mean vocal intensity of 7.00-dB SPL (P<0.001) were found using amplification, along with significant decreases (P=0.001) in cycle dose and distance dose. In addition, mean phonation time was found to decrease using amplification (P=0.023). These data suggest that voice amplification may be an effective intervention to decrease the potentially damaging vocal loads experienced by elementary music teachers in the classroom. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
R. J. Klos; G. G. Wang; W. L. Bauerle
2010-01-01
Analyses of forest health indicators monitored through the Forest Health and Monitoring (FHM) program suggested that weather was the most important cause of tree mortality. Drought is of particular importance among weather variables because several global climate change scenarios predicted more frequent and/or intense drought in the Southeastern United States. During...
Onion skin as a radiation monitor
NASA Astrophysics Data System (ADS)
Desrosiers, Marc F.; McLaughlin, William L.
The ESR spectra of the dry, outer skin of onion, red onion, garlic, and shallot were measured before and after irradiation. In all spectra only a single resonance (g = 2.00) was observed. The ESR signal intensity increased with absorbed dose, however, the radiation-induced signal decayed slowly with time. It was concluded that the outer skin of these foods are not suitable as a long-term postirradiation monitor.
Potential for boom-mounted remote sensing applications in seedling quality monitoring
Robert F. Keefe; Jan U. H. Eitel; Daniel S. Long; Anthony S. Davis; Paul Gessler; Alistair M. S. Smith
2009-01-01
Remotely sensed aerial and satellite sensor imagery is widely used for classification of vegetation structure and health on industrial and public lands. More intensively than at any other time in the life of a planted tree, its health and status will be maintained and monitored while under culture in a bareroot or container nursery. As a case in point, inventories to...
Ernest Hartley
2000-01-01
This long-term study, monitoring visitor impact on subalpine vegetation beginning in 1967, revealed that after 30 years all treatment plots had returned to pre-treatment ratios of vegetation (all species combined), organic litter and bare ground. Higher trampling intensities produced longer term impacts. Vegetation cover recovered in 19 to 25 years when trampled 15...
Team Cappadocia Design for MAGIC 2010 (The ASELSAN Team)
2010-11-01
Also in another screen, OCU displays tactical information using 3D Geographical Information System (GIS) for enhanced situational awareness. OCU...number of local textural features such as mean and standard deviation of image intensity and gradient, Zernike moments, Haralick features...information for situational awareness on the 3D GIS tactical map and the other monitor is used for UGV status monitoring, command and control. Tactical
NASA Astrophysics Data System (ADS)
Ries, Thomas C.
1995-05-01
Two new movable beam intensity profile monitors have been installed into the TRIUMF Parity Experiment 497 Beamlines. Each unit serves two functions. Firstly, the beam median position, in a plane normal to the beam, is detected by split plate Secondary Emission Monitors. This information is used to lock the beam into the position of the movable monitor to within a few μm's via high band width ferrite core steering magnets operating in tandem in a closed loop servo feedback control system. Secondly, the beam profile and intensity is detected via a multi-wire secondary emission non-movable monitor, where the data provides high precision values regarding centroidal positions and profiles. The centroid position of the beam is statistically determined to an accuracy of ±10 μm from a data record length of 1 second. The design of each device adheres to strict standards of mechanically rigid construction. The split plate SEM accuracy and repeatability is better than 15 μm with an absolute resolution limit of 0.4 μm. Maximum travel is 2 inches in the vertical plane. Since the device is mechanically modular and both degrees of freedom are combined into a single mechanical unit, fast and easy handling is possible for maintenance in radioactive areas. The actuators are dc servo motors with tachometers driven by linear servo power amplifiers. These amplifiers are used in lieu of pulse width modulated amps to eliminate noise produced by the switching circuits. Position sensing is done by variable reluctance type absolute rotary encoders providing 16 bit resolution over the full range of travel. Positioning is done manually using a self centring potentiometer on the control panel that provides a ± velocity command signal to the power amplifiers. This configuration ensures good controllability over a very large range of positioning speeds hence making 0.4 μm incremental positioning possible, as well as, fast relocations over large relative distances. The precision movement and jitter was measured in the laboratory. Examples will be given of the monitor use with beam.
Healthcare professionals' views of smart glasses in intensive care: A qualitative study.
Romare, Charlotte; Hass, Ursula; Skär, Lisa
2018-04-01
The aim of this study was to describe healthcare professionals' views of smart glasses before their implementation in an intensive care unit, both regarding quality of use of the glasses and to identify possible intensive care situations where the glasses could be used to increase patient safety. Data were generated through focus group interviews and analysed using thematic content analysis. The findings describe participants' views of smart glasses divided into three categories; Smart glasses to facilitate work at intensive care unit; Quality of use and Utilisation. Participants assumed smart glasses to cause both effect and affect in intensive care. Participants' concern for patients arose recurrently and through their concern intention to work to promote patient safety. Smart glasses are suggested as a complement to existing monitoring and routines and cannot replace human presence in intensive care. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Application of FBG sensors in strengthening and maintenance monitoring of old bridges
NASA Astrophysics Data System (ADS)
Yue, Li-na; Huang, Jun; Yang, Yan
2009-10-01
The various fiber Bragg grating(FBG)sensors such as FBG force rings, differential FBG displacement cells, FBG strain sensors and FBG temperature sensors had been used to monitor the strengthening and maintenance process of the continuous concrete beam bridges and the continuous concrete rigid frame bridges which are the part of Wuhan Second Yangtze River Bridge. In the strengthening and maintenance process, the tension force of the external prestressed tendons, the cracks change and intensity of cross sections had been monitored to insure the instruction safety, study the effect of strengthening and maintenance, and verify the design theories of strengthening and maintenance. Also the reference state criterion for long-term bridge health monitoring had been provided according to the monitoring results.
Towards continuous monitoring of pulse rate in neonatal intensive care unit with a webcam.
Mestha, Lalit K; Kyal, Survi; Xu, Beilei; Lewis, Leslie Edward; Kumar, Vijay
2014-01-01
We describe a novel method to monitor pulse rate (PR) on a continuous basis of patients in a neonatal intensive care unit (NICU) using videos taken from a high definition (HD) webcam. We describe algorithms that determine PR from videoplethysmographic (VPG) signals extracted from multiple regions of interest (ROI) simultaneously available within the field of view of the camera where cardiac signal is registered. We detect motion from video images and compensate for motion artifacts from each ROI. Preliminary clinical results are presented on 8 neonates each with 30 minutes of uninterrupted video. Comparisons to hospital equipment indicate that the proposed technology can meet medical industry standards and give improved patient comfort and ease of use for practitioners when instrumented with proper hardware.
Detecting crop population growth using chlorophyll fluorescence imaging.
Wang, Heng; Qian, Xiangjie; Zhang, Lan; Xu, Sailong; Li, Haifeng; Xia, Xiaojian; Dai, Liankui; Xu, Liang; Yu, Jingquan; Liu, Xu
2017-12-10
For both field and greenhouse crops, it is challenging to evaluate their growth information on a large area over a long time. In this work, we developed a chlorophyll fluorescence imaging-based system for crop population growth information detection. Modular design was used to make the system provide high-intensity uniform illumination. This system can perform modulated chlorophyll fluorescence induction kinetics measurement and chlorophyll fluorescence parameter imaging over a large area of up to 45 cm×34 cm. The system can provide different lighting intensity by modulating the duty cycle of its control signal. Results of continuous monitoring of cucumbers in nitrogen deficiency show the system can reduce the judge error of crop physiological status and improve monitoring efficiency. Meanwhile, the system is promising in high throughput application scenarios.
Mason C. Carter; Thomas J. Dean; Minyi Zhou; Michael G. Messina; Ziyin Wang
2002-01-01
In affiliation with the USDA-FS long-term soil productivity program, a series of studies have been established in the US gulf coast region to monitor the effects of intensive silviculture on site productivity. This report presents early results of a study of the interactive effects of harvest intensity and cultural treatments on soil C, N, and biological processes...
2006-01-01
cough. Pain was assessed during incentive spirometry or coughing using a visual analogue scale (score from 1 to 10) with failure being a score...fracture multidisciplinary clinical pathway. SIMU Surgical Intermediate Care Unit; STICU Shock Trauma Intensive Care Unit; IS incentive spirometry ...monitored bed (Surgical Intermediate Care Unit or Shock Trauma Intensive Care Unit) where they received patient-controlled analgesia and incentive
1987-09-01
of Intensive Cognitive Diagnosis and Its Implications for Testing Stellan Ohisson Learning Research and Development Center, University of Pittsburgh...7a. NAME OF MONITORING ORGANIZATION Learning Research & Development (if applicable) Cognitive Science Program Center, University of Pittsburg Office of...GAGE All other eaitions are obolSete. UN CLASS " UNLASSI FIED Ohlsson 1 Trace Analysis Knowledge and Understanding in Human Learning Knowledge and
NASA Astrophysics Data System (ADS)
Gray, Robert H. R.; Leslie, Thomas A.; Civale, John; Kennedy, James E.; ter Haar, Gail
2007-05-01
Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.
A Telephone-based Physiotherapy Intervention for Patients with Osteoarthritis of the Knee
Odole, Adesola C.; Ojo, Oluwatobi D.
2013-01-01
This study assessed the effects of a 6-week telephone based intervention on the pain intensity and physical function of patients with knee osteoarthritis (OA), and compared the results to physiotherapy conducted in the clinic. Fifty randomly selected patients with knee OA were assigned to one of two treatment groups: a clinic group (CG) and a tele-physiotherapy group (TG). The CG received thrice-weekly physiotherapist administered osteoarthritis-specific exercises in the clinic for six weeks. The TG received structured telephone calls thrice-weekly at home, to monitor self-administered osteoarthritis-specific exercises. Participants’ pain intensity and physical function were assessed at baseline, two, four, and six weeks, in the clinic environment. Within group comparison showed significant improvements across baseline, and at weeks two, four, and six for both TG and CG’s pain intensity and physical function. Between-group comparison of CG and TG’s pain intensity and physical function at baseline and weeks two, four, and six showed no significant differences. This study demonstrated that a six-week course of structured telephone calls thrice-weekly to patients at their home, to monitor self-administered osteoarthritis-specific exercises for patients with knee OA (i.e., tele-physiotherapy) achieved comparable results to physiotherapy conducted in the clinic. PMID:25945214
Dynamic composition of medical support services in the ICU: Platform and algorithm design details.
Hristoskova, Anna; Moeyersoon, Dieter; Van Hoecke, Sofie; Verstichel, Stijn; Decruyenaere, Johan; De Turck, Filip
2010-12-01
The Intensive Care Unit (ICU) is an extremely data-intensive environment where each patient needs to be monitored 24/7. Bedside monitors continuously register vital patient values (such as serum creatinine, systolic blood pressure) which are recorded frequently in the hospital database (e.g. every 2 min in the ICU of the Ghent University Hospital), laboratories generate hundreds of results of blood and urine samples, and nurses measure blood pressure and temperature up to 4 times an hour. The processing of such large amount of data requires an automated system to support the physicians' daily work. The Intensive Care Service Platform (ICSP) offers the needed support through the development of medical support services for processing and monitoring patients' data. With an increased deployment of these medical support services, reusing existing services as building blocks to create new services offers flexibility to the developer and accelerates the design process. This paper presents a new addition to the ICSP, the Dynamic Composer for Web services. Based on a semantic description of the medical support services, this Composer enables a service to be executed by creating a composition of medical services that provide the needed calculations. The composition is achieved using various algorithms satisfying certain quality of service (QoS) constraints and requirements. In addition to the automatic composition the paper also proposes a recovery mechanism in case of unavailable services. When executing the composition of medical services, unavailable services are dynamically replaced by equivalent services or a new composition achieving the same result. The presented platform and QoS algorithms are put through extensive performance and scalability tests for typical ICU scenarios, in which basic medical services are composed to a complex patient monitoring service. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Evaluation of a novel canine activity monitor for at-home physical activity analysis.
Yashari, Jonathan M; Duncan, Colleen G; Duerr, Felix M
2015-07-04
Accelerometers are motion-sensing devices that have been used to assess physical activity in dogs. However, the lack of a user-friendly, inexpensive accelerometer has hindered the widespread use of this objective outcome measure in veterinary research. Recently, a smartphone-based, affordable activity monitor (Whistle) has become available for measurement of at-home physical activity in dogs. The aim of this research was to evaluate this novel accelerometer. Eleven large breed, privately owned dogs wore a collar fitted with both the Whistle device and a previously validated accelerometer-based activity monitor (Actical) for a 24-h time period. Owners were asked to have their dogs resume normal daily activities. Total activity time obtained from the Whistle device in minutes was compared to the total activity count from the Actical device. Activity intensity from the Whistle device was calculated manually from screenshots of the activity bars displayed in the smartphone-application and compared to the activity count recorded by the Actical in the same 3-min time period. A total of 3740 time points were compared. There was a strong correlation between activity intensity of both devices for individual time points (Pearson's correlation coefficient 0.81, p < 0.0001). An even stronger correlation was observed between the total activity data between the two devices (Pearson's correlation coefficient 0.925, p < 0.0001). Activity data provided by the Whistle activity monitor may be used as an objective outcome measurement in dogs. The total activity time provided by the Whistle application offers an inexpensive method for obtaining at-home, canine, real-time physical activity data. Limitations of the Whistle device include the limited battery life, the need for manual derivation of activity intensity data and data transfer, and the requirement of Wi-Fi and Bluetooth availability for data transmission.
Monitoring An Intensive Dust Event over Northern China Using Multi-satellite Observation
NASA Astrophysics Data System (ADS)
She, L.; Xue, Y.; Guang, J.; Mei, L.; Che, Y.; Fan, C.; Xie, Y.
2017-12-01
The deserts in western/northern China are one of the major mineral dust source regions of the world. Large amount of dust are emitted and blown east and southeast, especially in spring. An intensive dust event occurred over Northern China during May 3 - 8, 2017. The dust storms came from deserts in China and Mongolia. Due to the long-distance transport, more than ten provinces were affected by this dust event, several provinces occurred strong dust storm. In this study, multi-satellite data were employed to analyse the spatial-temporal evolution and dynamic transport behaviour of the dust plume, especially the geostationary satellite data - Himawari8 Advanced Himawari Imager (AHI) data. AHI data was used to estimate hourly Aerosol Optical Depth (AOD) to monitoring the aerosol distribution as well as the dust plume movements, as the dust storms often characterized by high AOD. A simple dust index was also calculated based on AHI VIS and TIR data to estimate the dust intensity. Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) data and the Ozone Monitoring Instrument (OMI) Aerosol Index were used as additional data sources to monitor the dust vertical distribution and provide independent information of dust presence. MODIS aerosol product and AERONET aerosol measurements were compared with the AHI retrieved AODs, the comparisons show a good agreement. The dust index was compared with the ground measurements as well as the corresponding RGB image. Simulations from HYSPLIT back-trajectory analysis shows similar temporal variation with the calculated AOD and dust index of the dust plume. Those comparisons with other satellite products and ground measurements suggested both the calculated AOD and dust index well depicted the dust events compared.
In situ monitoring of the integrity of bonded repair patches on aircraft and civil infrastructures
NASA Astrophysics Data System (ADS)
Kumar, Amrita; Roach, Dennis; Beard, Shawn; Qing, Xinlin; Hannum, Robert
2006-03-01
Monitoring the continued health of aircraft subsystems and identifying problems before they affect airworthiness has been a long-term goal of the aviation industry. Because in-service conditions and failure modes experienced by structures are generally complex and unknown, conservative calendar-based or usage-based scheduled maintenance practices are overly time-consuming, labor-intensive and expensive. Metal structures such as helicopters and other transportation systems are likely to develop fatigue cracks under cyclic loads and corrosive service environments. Early detection of cracks is a key element to prevent catastrophic failure and prolong structural life. Furthermore, as structures age, maintenance service frequency and costs increase while performance and availability decrease. Current non-destructive inspection (NDI) techniques that can potentially be used for this purpose typically involve complex, time-intensive procedures, which are labor-intensive and expensive. Most techniques require access to the damaged area on at least one side, and sometimes on both sides. This can be very difficult for monitoring of certain inaccessible regions. In those cases, inspection may require removal of access panels or even structural disassembly. Once access has been obtained, automated inspection techniques likely will not be practical due to the bulk of the required equipment. Results obtained from these techniques may also be sensitive to the sweep speed, tool orientation, and downward pressure. This can be especially problematic for hand-held inspection tools where none of these parameters is mechanically controlled. As a result, data can vary drastically from one inspection to the next, from one technician to the next, and even from one sweep to the next. Structural health monitoring (SHM) offers the promise of a paradigm shift from schedule-driven maintenance to condition-based maintenance (CBM) of assets. Sensors embedded permanently in aircraft safety critical structures that can monitor damage can provide for improved reliability and streamlining of aircraft maintenance. Early detection of damage such as fatigue crack initiation can improve personnel safety and prolong service life. This paper presents the testing of an acousto-ultrasonic piezoelectric sensor based structural health monitoring system for real-time monitoring of fatigue cracks and disbonds in bonded repairs. The system utilizes a network of distributed miniature piezoelectric sensors/actuators embedded on a thin dielectric carrier film, to query, monitor and evaluate the condition of a structure. The sensor layers are extremely flexible and can be integrated with any type of metal or composite structure. Diagnostic signals obtained from a structure during structural monitoring are processed by a portable diagnostic unit. With appropriate diagnostic software, the signals can be analyzed to ascertain the integrity of the structure being monitored. Details on the system, its integration and examples of detection of fatigue crack and disbond growth and quantification for bonded repairs will be presented here.
Viddeleer, Alain R; Sijens, Paul E; van Ooijen, Peter M A; Kuypers, Paul D L; Hovius, Steven E R; Oudkerk, Matthijs
2009-08-01
Nerve regeneration could be monitored by comparing MRI image intensities in time, as denervated muscles display increased signal intensity in STIR sequences. In this study long-term reproducibility of STIR image intensity was assessed under clinical conditions and the required image intensity nonuniformity correction was improved by using phantom scans obtained at multiple positions. Three-dimensional image intensity nonuniformity was investigated in phantom scans. Next, over a three-year period, 190 clinical STIR hand scans were obtained using a standardized acquisition protocol, and corrected for intensity nonuniformity by using the results of phantom scanning. The results of correction with 1, 3, and 11 phantom scans were compared. The image intensities in calibration tubes close to the hands were measured every time to determine the reproducibility of our method. With calibration, the reproducibility of STIR image intensity improved from 7.8 to 6.4%. Image intensity nonuniformity correction with 11 phantom scans gave significantly better results than correction with 1 or 3 scans. The image intensities in clinical STIR images acquired at different times can be compared directly, provided that the acquisition protocol is standardized and that nonuniformity correction is applied. Nonuniformity correction is preferably based on multiple phantom scans.
Michael, Scott; Graham, Kenneth S; Davis, Glen M
2017-01-01
Cardiac parasympathetic activity may be non-invasively investigated using heart rate variability (HRV), although HRV is not widely accepted to reflect sympathetic activity. Instead, cardiac sympathetic activity may be investigated using systolic time intervals (STI), such as the pre-ejection period. Although these autonomic indices are typically measured during rest, the "reactivity hypothesis" suggests that investigating responses to a stressor (e.g., exercise) may be a valuable monitoring approach in clinical and high-performance settings. However, when interpreting these indices it is important to consider how the exercise dose itself (i.e., intensity, duration, and modality) may influence the response. Therefore, the purpose of this investigation was to review the literature regarding how the exercise dosage influences these autonomic indices during exercise and acute post-exercise recovery. There are substantial methodological variations throughout the literature regarding HRV responses to exercise, in terms of exercise protocols and HRV analysis techniques. Exercise intensity is the primary factor influencing HRV, with a greater intensity eliciting a lower HRV during exercise up to moderate-high intensity, with minimal change observed as intensity is increased further. Post-exercise, a greater preceding intensity is associated with a slower HRV recovery, although the dose-response remains unclear. A longer exercise duration has been reported to elicit a lower HRV only during low-moderate intensity and when accompanied by cardiovascular drift, while a small number of studies have reported conflicting results regarding whether a longer duration delays HRV recovery. "Modality" has been defined multiple ways, with limited evidence suggesting exercise of a greater muscle mass and/or energy expenditure may delay HRV recovery. STI responses during exercise and recovery have seldom been reported, although limited data suggests that intensity is a key determining factor. Concurrent monitoring of HRV and STI may be a valuable non-invasive approach to investigate autonomic stress reactivity; however, this integrative approach has not yet been applied with regards to exercise stressors.
Ruffino, José S; Songsorn, Preeyaphorn; Haggett, Malindi; Edmonds, Daniel; Robinson, Anthony M; Thompson, Dylan; Vollaard, Niels B J
2017-02-01
Reduced-exertion high-intensity interval training (REHIT) is a genuinely time-efficient intervention that can improve aerobic capacity and insulin sensitivity in sedentary individuals. The present study compared the effects of REHIT and moderate-intensity walking on health markers in patients with type 2 diabetes (T2D) in a counter-balanced crossover study. Sixteen men with T2D (mean ± SD age: 55 ± 5 years, body mass index: 30.6 ± 2.8 kg·m -2 , maximal aerobic capacity: 27 ± 4 mL·kg -1 ·min -1 ) completed 8 weeks of REHIT (three 10-min low-intensity cycling sessions/week with two "all-out" 10-20-s sprints) and 8 weeks of moderate-intensity walking (five 30-min sessions/week at an intensity corresponding to 40%-55% of heart-rate reserve), with a 2-month wash-out period between interventions. Before and after each intervention, participants underwent an incremental fitness test, an oral glucose tolerance test (OGTT), a whole-body dual-energy X-ray absorptiometry scan, and continuous glucose monitoring. REHIT was associated with a significantly larger increase in maximal aerobic capacity compared with walking (7% vs. 1%; time × intervention interaction effect: p < 0.05). Both REHIT and walking decreased resting mean arterial pressure (-4%; main effect of time: p < 0.05) and plasma fructosamine (-5%; main effect of time: p < 0.05). Neither intervention significantly improved OGTT-derived measures of insulin sensitivity, glycaemic control measured using continuous glucose monitors, blood lipid profile, or body composition. We conclude that REHIT is superior to a 5-fold larger volume of moderate-intensity walking in improving aerobic fitness, but similar to walking REHIT is not an effective intervention for improving insulin sensitivity or glycaemic control in T2D patients in the short term.
Michael, Scott; Graham, Kenneth S.; Davis, Glen M.
2017-01-01
Cardiac parasympathetic activity may be non-invasively investigated using heart rate variability (HRV), although HRV is not widely accepted to reflect sympathetic activity. Instead, cardiac sympathetic activity may be investigated using systolic time intervals (STI), such as the pre-ejection period. Although these autonomic indices are typically measured during rest, the “reactivity hypothesis” suggests that investigating responses to a stressor (e.g., exercise) may be a valuable monitoring approach in clinical and high-performance settings. However, when interpreting these indices it is important to consider how the exercise dose itself (i.e., intensity, duration, and modality) may influence the response. Therefore, the purpose of this investigation was to review the literature regarding how the exercise dosage influences these autonomic indices during exercise and acute post-exercise recovery. There are substantial methodological variations throughout the literature regarding HRV responses to exercise, in terms of exercise protocols and HRV analysis techniques. Exercise intensity is the primary factor influencing HRV, with a greater intensity eliciting a lower HRV during exercise up to moderate-high intensity, with minimal change observed as intensity is increased further. Post-exercise, a greater preceding intensity is associated with a slower HRV recovery, although the dose-response remains unclear. A longer exercise duration has been reported to elicit a lower HRV only during low-moderate intensity and when accompanied by cardiovascular drift, while a small number of studies have reported conflicting results regarding whether a longer duration delays HRV recovery. “Modality” has been defined multiple ways, with limited evidence suggesting exercise of a greater muscle mass and/or energy expenditure may delay HRV recovery. STI responses during exercise and recovery have seldom been reported, although limited data suggests that intensity is a key determining factor. Concurrent monitoring of HRV and STI may be a valuable non-invasive approach to investigate autonomic stress reactivity; however, this integrative approach has not yet been applied with regards to exercise stressors. PMID:28611675
NASA Astrophysics Data System (ADS)
McLennan, D.; Kehler, D.
2016-12-01
The Canadian High Arctic Research Station (CHARS) is scheduled for completion in July 2017 and is the northern science component of Polar Knowledge Canada (POLAR). A mandated goal for POLAR is to establish the adjacent Experimental and Reference Area (ERA) as an Arctic Flagship monitoring site that will track change in Arctic terrestrial, freshwater and marine ecosystems. Situated in the community of Cambridge Bay, CHARS provides the opportunity to draw on the Indigenous Knowledge of local residents to help design and conduct the monitoring, and to operate 12 months a year. Monitoring at CHARS will be linked to networks nationally and internationally, and is being designed so that change in key indicators can be understood in terms of drivers and processes, modeled and scaled up regionally, and used to predict important changes in critical indicators. As a partner in the Circumpolar Biodiversity Monitoring Program (CBMP), the monitoring design for terrestrial ecosystems follows approaches outlined by the CBMP Terrestrial Expert Monitoring Group, who have listed key monitoring questions and identified a list of important Focal Ecosystem Components (FECs). To link drivers to FECs we are proposing a multi-scaled approach: 1) an Intensive Monitoring Area to establish replicated monitoring plots that track change in snow depth and condition, active layer depth, soil temperature, soil moisture, and soil solution chemistry that are spatially and temporally linked to changes in microbiological activity, CO2/CH4 net ecosystem flux, vegetation relative frequency, species composition, growth and foliar nutrient concentration, arthropod abundance, lemming abundance and health, and shorebird/songbird abundance and productivity. 2) These intensive observations are supported by watershed scale measures that will monitor, during the growing season, lemming winter nest abundance, songbird, shorebird and waterfowl staging and nesting, and other observations; in the winter we will monitor muskoxen, caribou, Arctic hare, wolf and Arctic fox using tracks and DNA analysis of fresh scat. 3) Ground measures will be supported by aerial flights and satellite remote sensing approaches to reach out with regional calibration-validation. Feedback is being sought at this time on project design, implementation and scope.
Cosmic ray intensity gradients in the solar system
NASA Technical Reports Server (NTRS)
Mckibben, R. B.
1975-01-01
Recent progress in the determination of cosmic-ray intensity gradients is reviewed. Direct satellite measurements of the integral gradient are described together with various types of indirect measurements, including measurements of the Ar-37/Ar-39 ratio in samples from the Lost City meteorite, studies of anisotropies in neutron-monitor counting rates, and analysis of the sidereal diurnal anisotropy observed at a single point on earth. Nucleonic radial gradients and electron gradients measured by satellites in differential energy windows are discussed, and theoretical studies of the physical processes involved in these gradients are summarized. Observations of intensity gradients in heliographic latitude are reported.
Bayer, Jennifer M.; Scully, Rebecca A.; Weltzin, Jake F.
2018-05-21
Natural resource managers who oversee the Nation’s resources require data to support informed decision-making at a variety of spatial and temporal scales that often cross typical jurisdictional boundaries such as states, agency regions, and watersheds. These data come from multiple agencies, programs, and sources, often with their own methods and standards for data collection and organization. Coordinating standards and methods is often prohibitively time-intensive and expensive. MonitoringResources.org offers a suite of tools and resources that support coordination of monitoring efforts, cost-effective planning, and sharing of knowledge among organizations. The website was developed by the Pacific Northwest Aquatic Monitoring Partnership—a collaboration of Federal, state, tribal, local, and private monitoring programs—and the U.S. Geological Survey (USGS), with funding from the Bonneville Power Administration and USGS. It is a key component of a coordinated monitoring and information network.
A Mobile Multi-Agent Information System for Ubiquitous Fetal Monitoring
Su, Chuan-Jun; Chu, Ta-Wei
2014-01-01
Electronic fetal monitoring (EFM) systems integrate many previously separate clinical activities related to fetal monitoring. Promoting the use of ubiquitous fetal monitoring services with real time status assessments requires a robust information platform equipped with an automatic diagnosis engine. This paper presents the design and development of a mobile multi-agent platform-based open information systems (IMAIS) with an automated diagnosis engine to support intensive and distributed ubiquitous fetal monitoring. The automatic diagnosis engine that we developed is capable of analyzing data in both traditional paper-based and digital formats. Issues related to interoperability, scalability, and openness in heterogeneous e-health environments are addressed through the adoption of a FIPA2000 standard compliant agent development platform—the Java Agent Development Environment (JADE). Integrating the IMAIS with light-weight, portable fetal monitor devices allows for continuous long-term monitoring without interfering with a patient’s everyday activities and without restricting her mobility. The system architecture can be also applied to vast monitoring scenarios such as elder care and vital sign monitoring. PMID:24452256
Imaging monitored loosening of dense fibrous tissues using high-intensity pulsed ultrasound
NASA Astrophysics Data System (ADS)
Yeh, Chia-Lun; Li, Pai-Chi; Shih, Wen-Pin; Huang, Pei-Shin; Kuo, Po-Ling
2013-10-01
Pulsed high-intensity focused ultrasound (HIFU) is proposed as a new alternative treatment for contracture of dense fibrous tissue. It is hypothesized that the pulsed-HIFU can release the contracted tissues by attenuating tensile stiffness along the fiber axis, and that the stiffness reduction can be quantitatively monitored by change of B-mode images. Fresh porcine tendons and ligaments were adapted to an ex vivo model and insonated with pulsed-HIFU for durations ranging from 5 to 30 min. The pulse length was 91 µs with a repetition frequency of 500 Hz, and the peak rarefactional pressure was 6.36 MPa. The corresponding average intensities were kept around 1606 W cm-2 for ISPPA and 72.3 W cm-2 for ISPTA. B-mode images of the tissues were acquired before and after pulsed-HIFU exposure, and the changes in speckle intensity and organization were analyzed. The tensile stiffness of the HIFU-exposed tissues along the longitudinal axis was examined using a stretching machine. Histology examinations were performed by optical and transmission electron microscopy. Pulsed-HIFU exposure significantly decreased the tensile stiffness of the ligaments and tendons. The intensity and organization of tissue speckles in the exposed region were also decreased. The speckle changes correlated well with the degree of stiffness alteration. Histology examinations revealed that pulsed-HIFU exposure probably damages tissues via a cavitation-mediated mechanism. Our results suggest that pulsed-HIFU with a low duty factor is a promising tool for developing new treatment strategies for orthopedic disorders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trentadue, R.; Clemencic, M.; Dykstra, D.
The LCG Persistency Framework consists of three software packages (CORAL, COOL and POOL) that address the data access requirements of the LHC experiments in several different areas. The project is the result of the collaboration between the CERN IT Department and the three experiments (ATLAS, CMS and LHCb) that are using some or all of the Persistency Framework components to access their data. POOL is a hybrid technology store for C++ objects, using a mixture of streaming and relational technologies to implement both object persistency and object metadata catalogs and collections. CORAL is an abstraction layer with an SQL-free APImore » for accessing data stored using relational database technologies. COOL provides specific software components and tools for the handling of the time variation and versioning of the experiment conditions data. This presentation reports on the status and outlook in each of the three sub-projects at the time of the CHEP2012 conference, reviewing the usage of each package in the three LHC experiments.« less
[A frame nearly without retouch of the Public Health post-graduation alumni, 1998-2007].
Gomes, Mara Helena de Andréa; Goldenberg, Paulete
2010-07-01
We present the results of a data collection that allowed to identify where are and what the alumni of the Public Health post-graduation programs think about some attributes of their post-graduation, from 1998 to 2007. By means of two distinctive and concomitant phases, this subproject was initiated with information request along with the programs. The answers allowed the construction of a student census that defended thesis or equivalent, in three modalities: doctorate, academic and professional master. Besides the data provision that allowed us to construct and describe an academic-professional profile of the Public Health area alumni, the information allowed electronic contact with most of the alumni located. In the second phase, we sent the alumni a form to be answered online, with appreciative questions regarding the role of the post graduation on their intellectual and professional path, aiming to characterize their post-graduation degree. We forwarded some suggestions to future researches, as for example the creation of a standardized and digitalized enrollment form open to consultation.
Schiotis, Ruxandra; Font, Pilar; Zarco, Pedro; Almodovar, Raquel; Gratacós, Jordi; Mulero, Juan; Juanola, Xavier; Montilla, Carlos; Moreno, Estefanía; Ariza Ariza, Rafael; Collantes-Estevez, Eduardo
2011-01-01
Objective. To present the usefulness of a centralized system of data collection for the development of an international multicentre registry of SpA. Method. The originality of this registry consists in the creation of a virtual network of researchers in a computerized Internet database. From its conception, the registry was meant to be a dynamic acquiring system. Results. REGISPONSER has two developing phases (Conception and Universalization) and gathers several evolving secondary projects (REGISPONSER-EARLY, REGISPONSER-AS, ESPERANZA and RESPONDIA). Each sub-project answered the necessity of having more specific and complete data of the patients even from the onset of the disease so, in the end, obtaining a well-defined picture of SpAs spectrum in the Spanish population. Conclusion. REGISPONSER is the first dynamic SpA database composed of cohorts with a significant number of patients distributed by specific diagnosis, which provides basic specific information of the sub-cohorts useful for patients’ evaluation in rheumatology ambulatory consulting. PMID:20823095
Sampling and analysis plan for sludge located on the floor and in the pits of the 105-K basins
DOE Office of Scientific and Technical Information (OSTI.GOV)
BAKER, R.B.
1998-11-20
This Sampling and Analysis Plan (SAP) provides direction for the sampling of the sludge found on the floor and in the remote pits of the 105-K Basins to provide: (1) basic data for the sludges that have not been characterized to-date and (2) representative Sludge material for process tests to be made by the SNF Project/K Basins sludge treatment process subproject. The sampling equipment developed will remove representative samples of the radioactive sludge from underwater at the K Basins, depositing them in shielded containers for transport to the Hanford Site laboratories. Included in the present document is the basic backgroundmore » logic for selection of the samples to meet the requirements established in the Data Quality Objectives (DQO), HNF-2033, for this sampling activity. The present document also includes the laboratory analyses, methods, procedures, and reporting that will be required to meet the DQO.« less
Full-Scale Turbofan Engine Noise-Source Separation Using a Four-Signal Method
NASA Technical Reports Server (NTRS)
Hultgren, Lennart S.; Arechiga, Rene O.
2016-01-01
Contributions from the combustor to the overall propulsion noise of civilian transport aircraft are starting to become important due to turbofan design trends and expected advances in mitigation of other noise sources. During on-ground, static-engine acoustic tests, combustor noise is generally sub-dominant to other engine noise sources because of the absence of in-flight effects. Consequently, noise-source separation techniques are needed to extract combustor-noise information from the total noise signature in order to further progress. A novel four-signal source-separation method is applied to data from a static, full-scale engine test and compared to previous methods. The new method is, in a sense, a combination of two- and three-signal techniques and represents an attempt to alleviate some of the weaknesses of each of those approaches. This work is supported by the NASA Advanced Air Vehicles Program, Advanced Air Transport Technology Project, Aircraft Noise Reduction Subproject and the NASA Glenn Faculty Fellowship Program.
Airframe Research and Technology for Hypersonic Airbreathing Vehicles
NASA Technical Reports Server (NTRS)
Glass, David E.; Merski, N. Ronald; Glass, Christopher E.
2002-01-01
The Hypersonics Investment Area (HIA) within NASA's Advanced Space Transportation Program (ASTP) has the responsibility to develop hypersonic airbreathing vehicles for access to space. The Airframe Research and Technology (AR and T) Project, as one of six projects in the HIA, will push the state-of-the-art in airframe and vehicle systems for low-cost, reliable, and safe space transportation. The individual technologies within the project are focused on advanced, breakthrough technologies in airframe and vehicle systems and cross-cutting activities that are the basis for improvements in these disciplines. Both low and medium technology readiness level (TRL) activities are being pursued. The key technical areas that will be addressed by the project include analysis and design tools, integrated vehicle health management (IVHM), composite (polymer, metal, and ceramic matrix) materials development, thermal/structural wall concepts, thermal protection systems, seals, leading edges, aerothermodynamics, and airframe/propulsion flowpath technology. Each of the technical areas or sub-projects within the Airframe R and T Project is described in this paper.
Legal and financial methods for reducing low emission sources: Options for incentives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samitowski, W.
1995-12-31
There are two types of the so-called low emission sources in Cracow: over 1,000 local boiler houses and several thousand solid fuel-fired stoves. The accomplishment of each of 5 sub-projects offered under the American-Polish program entails solving the technical, financial, legal and public relations-related problems. The elimination of the low emission source requires, therefore, a joint effort of the following pairs: (a) local authorities, (b) investors, (c) owners and users of low emission sources, and (d) inhabitants involved in particular projects. The results of the studies developed by POLINVEST indicate that the accomplishment of the projects for the elimination ofmore » low emission sources will require financial incentives. Bearing in mind the today`s resources available from the community budget, this process may last as long as a dozen or so years. The task of the authorities of Cracow City is making a long-range operational strategy enabling reduction of low emission sources in Cracow.« less
Microphysical and Optical Properties of Saharan Dust Measured during the ICE-D Aircraft Campaign
NASA Astrophysics Data System (ADS)
Ryder, Claire; Marenco, Franco; Brooke, Jennifer; Cotton, Richard; Taylor, Jonathan
2017-04-01
During August 2015, the UK FAAM BAe146 research aircraft was stationed in Cape Verde off the coast of West Africa. Measurements of Saharan dust, and ice and liquid water clouds, were taken for the ICE-D (Ice in Clouds Experiment - Dust) project - a multidisciplinary project aimed at further understanding aerosol-cloud interactions. Six flights formed part of a sub-project, AER-D, solely focussing on measurements of Saharan dust within the African dust plume. Dust loadings observed during these flights varied (aerosol optical depths of 0.2 to 1.3), as did the vertical structure of the dust, the size distributions and the optical properties. The BAe146 was fully equipped to measure size distributions covering aerosol accumulation, coarse and giant modes. Initial results of size distribution and optical properties of dust from the AER-D flights will be presented, showing that a substantial coarse mode was present, in agreement with previous airborne measurements. Optical properties of dust relating to the measured size distributions will also be presented.
Review and assessment of the HOST turbine heat transfer program
NASA Technical Reports Server (NTRS)
Gladden, Herbert J.
1988-01-01
The objectives of the HOST Turbine Heat Transfer subproject were to obtain a better understanding of the physics of the aerothermodynamic phenomena occurring in high-performance gas turbine engines and to assess and improve the analytical methods used to predict the fluid dynamics and heat transfer phenomena. At the time the HOST project was initiated, an across-the-board improvement in turbine design technology was needed. Therefore, a building-block approach was utilized, with research ranging from the study of fundamental phenomena and analytical modeling to experiments in simulated real-engine environments. Experimental research accounted for 75 percent of the project, and analytical efforts accounted for approximately 25 percent. Extensive experimental datasets were created depicting the three-dimensional flow field, high free-stream turbulence, boundary-layer transition, blade tip region heat transfer, film cooling effects in a simulated engine environment, rough-wall cooling enhancement in a rotating passage, and rotor-stator interaction effects. In addition, analytical modeling of these phenomena was initiated using boundary-layer assumptions as well as Navier-Stokes solutions.
Passive Seismology On- and Offshore Costa Rica
NASA Astrophysics Data System (ADS)
Gossler, J.; Flueh, E.; Goltz, C.; Arroyo Hidalgo, I.; Boschini, I.; Mora, M.
2003-12-01
The theme of the National German Research Center SFB 574 "Volatiles and Fluids in Subduction Zones" subproject A2 is to understand the nature of coupling and mass transfer between upper and lower plate of the subduction zone in central Costa Rica. An amphibious seismic network, consisting of 23 ocean bottom sensors and 15 landstations, was deployed in the coastal Pacific region of central Costa Rica near Jaco in April 2002. The network was moved south-east towards Quepos in October 2002 and operated until spring this year. Our main objective is to detect and evaluate the seismicity induced by the convergent dynamics between the subducting oceanic lithosphere and the Caribbean plate. The spatial dimensions of the joined marine and land networks are designed to register events associated with the downgoing plate. We report details on the campaign and show first results of the standard investigation of the data (i.e. determinatin of hypocenters, magnitudes, polarities and focal mechanisms), including first interpretations.
Healy, Genevieve N; Wijndaele, Katrien; Dunstan, David W; Shaw, Jonathan E; Salmon, Jo; Zimmet, Paul Z; Owen, Neville
2008-02-01
We examined the associations of objectively measured sedentary time and physical activity with continuous indexes of metabolic risk in Australian adults without known diabetes. An accelerometer was used to derive the percentage of monitoring time spent sedentary and in light-intensity and moderate-to-vigorous-intensity activity, as well as mean activity intensity, in 169 Australian Diabetes, Obesity and Lifestyle Study (AusDiab) participants (mean age 53.4 years). Associations with waist circumference, triglycerides, HDL cholesterol, resting blood pressure, fasting plasma glucose, and a clustered metabolic risk score were examined. Independent of time spent in moderate-to-vigorous-intensity activity, there were significant associations of sedentary time, light-intensity time, and mean activity intensity with waist circumference and clustered metabolic risk. Independent of waist circumference, moderate-to-vigorous-intensity activity time was significantly beneficially associated with triglycerides. These findings highlight the importance of decreasing sedentary time, as well as increasing time spent in physical activity, for metabolic health.
NASA Astrophysics Data System (ADS)
Elblbesy, Mohamed A.
2017-12-01
Interacting electromagnetic field with the living organisms and cells became of the great interest in the last decade. Erythrocytes are the most common types of the blood cells and have unique rheological, electrical, and magnetic properties. Aggregation is one of the important characteristics of the erythrocytes which has a great impact in some clinical cases. The present study introduces a simple method to monitor the effect of static magnetic field on erythrocytes aggregation using light transmission. Features were extracted from the time course curve of the light transmission through the whole blood under different intensities of the magnetic field. The findings of this research showed that static magnetic field could influence the size and the rate of erythrocytes aggregation. The strong correlations confirmed these results between the static magnetic field intensity and both the time of aggregation and sedimentation of erythrocytes. From this study, it can be concluded that static magnetic field can be used to modify the mechanisms of erythrocytes aggregation.
Effect of cognitive load on speech prosody in aviation: Evidence from military simulator flights.
Huttunen, Kerttu; Keränen, Heikki; Väyrynen, Eero; Pääkkönen, Rauno; Leino, Tuomo
2011-01-01
Mental overload directly affects safety in aviation and needs to be alleviated. Speech recordings are obtained non-invasively and as such are feasible for monitoring cognitive load. We recorded speech of 13 military pilots while they were performing a simulator task. Three types of cognitive load (load on situation awareness, information processing and decision making) were rated by a flight instructor separately for each flight phase and participant. As a function of increased cognitive load, the mean utterance-level fundamental frequency (F0) increased, on average, by 7 Hz and the mean vocal intensity increased by 1 dB. In the most intensive simulator flight phases, mean F0 increased by 12 Hz and mean intensity, by 1.5 dB. At the same time, the mean F0 range decreased by 5 Hz, on average. Our results showed that prosodic features of speech can be used to monitor speaker state and support pilot training in a simulator environment. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.
NASA Astrophysics Data System (ADS)
Uijlenhoet, R.; de Vos, L. W.; Leijnse, H.; Overeem, A.; Raupach, T. H.; Berne, A.
2017-12-01
For the purpose of urban rainfall monitoring high resolution rainfall measurements are desirable. Typically C-band radar can provide rainfall intensities at km grid cells every 5 minutes. Opportunistic sensing with commercial microwave links yields rainfall intensities over link paths within cities. Additionally, recent developments have made it possible to obtain large amounts of urban in situ measurements from weather amateurs in near real-time. With a known high resolution simulated rainfall event the accuracy of these three techniques is evaluated, taking into account their respective existing layouts and sampling methods. Under ideal measurement conditions, the weather station networks proves to be most promising. For accurate estimation with radar, an appropriate choice for Z-R relationship is vital. Though both the microwave links and the weather station networks are quite dense, both techniques will underestimate rainfall if not at least one link path / station captures the high intensity rainfall peak. The accuracy of each technique improves when considering rainfall at larger scales, especially by increasing time intervals, with the steepest improvements found in microwave links.
AE characteristic for monitoring of fatigue crack in steel bridge members
NASA Astrophysics Data System (ADS)
Yoon, Dong-Jin; Jung, Juong-Chae; Park, Philip; Lee, Seung-Seok
2000-06-01
Acoustic emission technique was employed for the monitoring of crack activity in both steel bridge members and laboratory specimen. Laboratory experiment was carried out to identify AE characteristics of fatigue cracks for compact tension specimen. The relationship between a stress intensity factor and AE signals activity as well as conventional AE parameter analysis was discussed. A field test was also conducted on a railway bridge, which contain several fatigue cracks. Crack activities were investigated while in service with strain measurement. From the results, in the laboratory tests, the features of three parameters such as the length of crack growth, the AE energy, and the cumulative AE events, showed the almost same trend in their increase as the number of fatigue cycle increased. From the comparisons of peak amplitude and AE energy with stress intensity factor, it was verified that the higher stress intensity factors generated AE signals with higher peak amplitude and a large number of AE counts. In the field test, real crack propagation signals were captured and the crack activity was verified in two cases.
The application of dam break monitoring based on BJ-2 images
NASA Astrophysics Data System (ADS)
Cui, Yan; Li, Suju; Wu, Wei; Liu, Ming
2018-03-01
Flood is one of the major disasters in China. There are heavy intensity and wide range rainstorm during flood season in eastern part of China, and the flood control capacity of rivers is lower somewhere, so the flood disaster is abrupt and caused lots of direct economic losses. In this paper, based on BJ-2 Spatio-temporal resolution remote sensing data, reference image, 30-meter Global Land Cover Dataset(GlobeLand 30) and basic geographic data, forming Dam break monitoring model which including BJ-2 date processing sub-model, flood inundation range monitoring sub-model, dam break change monitoring sub-model and crop inundation monitoring sub-model. Case analysis in Poyang County Jiangxi province in 20th, Jun, 2016 show that the model has a high precision and could monitoring flood inundation range, crops inundation range and breach.
NASA Astrophysics Data System (ADS)
Han, Yang; Wang, Shutao; Payen, Thomas; Konofagou, Elisa
2017-04-01
The successful clinical application of high intensity focused ultrasound (HIFU) ablation depends on reliable monitoring of the lesion formation. Harmonic motion imaging guided focused ultrasound (HMIgFUS) is an ultrasound-based elasticity imaging technique, which monitors HIFU ablation based on the stiffness change of the tissue instead of the echo intensity change in conventional B-mode monitoring, rendering it potentially more sensitive to lesion development. Our group has shown that predicting the lesion location based on the radiation force-excited region is feasible during HMIgFUS. In this study, the feasibility of a fast lesion mapping method is explored to directly monitor the lesion map during HIFU. The harmonic motion imaging (HMI) lesion map was generated by subtracting the reference HMI image from the present HMI peak-to-peak displacement map, as streamed on the computer display. The dimensions of the HMIgFUS lesions were compared against gross pathology. Excellent agreement was found between the lesion depth (r 2 = 0.81, slope = 0.90), width (r 2 = 0.85, slope = 1.12) and area (r 2 = 0.58, slope = 0.75). In vivo feasibility was assessed in a mouse with a pancreatic tumor. These findings demonstrate that HMIgFUS can successfully map thermal lesions and monitor lesion development in real time in vitro and in vivo. The HMIgFUS technique may therefore constitute a novel clinical tool for HIFU treatment monitoring.
Han, Yang; Wang, Shutao; Payen, Thomas; Konofagou, Elisa
2017-04-21
The successful clinical application of high intensity focused ultrasound (HIFU) ablation depends on reliable monitoring of the lesion formation. Harmonic motion imaging guided focused ultrasound (HMIgFUS) is an ultrasound-based elasticity imaging technique, which monitors HIFU ablation based on the stiffness change of the tissue instead of the echo intensity change in conventional B-mode monitoring, rendering it potentially more sensitive to lesion development. Our group has shown that predicting the lesion location based on the radiation force-excited region is feasible during HMIgFUS. In this study, the feasibility of a fast lesion mapping method is explored to directly monitor the lesion map during HIFU. The harmonic motion imaging (HMI) lesion map was generated by subtracting the reference HMI image from the present HMI peak-to-peak displacement map, as streamed on the computer display. The dimensions of the HMIgFUS lesions were compared against gross pathology. Excellent agreement was found between the lesion depth (r 2 = 0.81, slope = 0.90), width (r 2 = 0.85, slope = 1.12) and area (r 2 = 0.58, slope = 0.75). In vivo feasibility was assessed in a mouse with a pancreatic tumor. These findings demonstrate that HMIgFUS can successfully map thermal lesions and monitor lesion development in real time in vitro and in vivo. The HMIgFUS technique may therefore constitute a novel clinical tool for HIFU treatment monitoring.