The birth of a quasiparticle in silicon observed in time-frequency space.
Hase, Muneaki; Kitajima, Masahiro; Constantinescu, Anca Monia; Petek, Hrvoje
2003-11-06
The concept of quasiparticles in solid-state physics is an extremely powerful tool for describing complex many-body phenomena in terms of single-particle excitations. Introducing a simple particle, such as an electron, hole or phonon, deforms a many-body system through its interactions with other particles. In this way, the added particle is 'dressed' or 'renormalized' by a self-energy cloud that describes the response of the many-body system, so forming a new entity--the quasiparticle. Using ultrafast laser techniques, it is possible to impulsively generate bare particles and observe their subsequent dressing by the many-body interactions (that is, quasiparticle formation) on the time and energy scales governed by the Heisenberg uncertainty principle. Here we describe the coherent response of silicon to excitation with a 10-femtosecond (10(-14) s) laser pulse. The optical pulse interacts with the sample by way of the complex second-order nonlinear susceptibility to generate a force on the lattice driving coherent phonon excitation. Transforming the transient reflectivity signal into frequency-time space reveals interference effects leading to the coherent phonon generation and subsequent dressing of the phonon by electron-hole pair excitations.
Coherent detection of THz-induced sideband emission from excitons in the nonperturbative regime
NASA Astrophysics Data System (ADS)
Uchida, K.; Otobe, T.; Mochizuki, T.; Kim, C.; Yoshita, M.; Tanaka, K.; Akiyama, H.; Pfeiffer, L. N.; West, K. W.; Hirori, H.
2018-04-01
Strong interaction of a terahertz (THz) wave with excitons induces nonperturbative optical effects such as Rabi splitting and high-order sideband generation. Here, we investigated coherent properties of THz-induced sideband emissions from GaAs/AlGaAs multiquantum wells. With increasing THz electric field, optical susceptibility of the THz-dressed exciton shows a redshift with spectral broadening and extraordinary phase shift. This implies that the field ionization of the 1 s exciton modifies the THz-dressed exciton in the nonperturbative regime.
Peroxide-based oxygen generating topical wound dressing for enhancing healing of dermal wounds.
Chandra, Prafulla K; Ross, Christina L; Smith, Leona C; Jeong, Seon S; Kim, Jaehyun; Yoo, James J; Harrison, Benjamin S
2015-01-01
Oxygen generating biomaterials represent a new trend in regenerative medicine that aims to generate and supply oxygen at the site of requirement, to support tissue healing and regeneration. To enhance the healing of dermal wounds, we have developed a highly portable, in situ oxygen generating wound dressings that uses sodium percarbonate (SPO) and calcium peroxide (CPO) as chemical oxygen sources. The dressing continuously generated oxygen for more than 3 days, after which it was replaced. In the in vivo testing on porcine full-thickness porcine wound model, the SPO/CPO dressing showed enhanced wound healing during the 8 week study period. Quantitative measurements of wound healing related parameters, such as wound closure, reepithelialization, epidermal thickness and collagen content of dermis showed that supplying oxygen topically using the SPO/CPO dressing significantly accelerated the wound healing. An increase in neovascularization, as determined using Von Willebrand factor (vWF) and CD31 staining, was also observed in the presence of SPO/CPO dressing. This novel design for a wound dressing that contains oxygen generating biomaterials (SPO/CPO) for supplying topical oxygen, may find utility in treating various types of acute to chronic wounds. © 2015 by the Wound Healing Society.
Van Hoesel, Willem; Tiefenbacher, Alexandra; König, Nina; Dorn, Verena M; Hagenguth, Julia F; Prah, Urša; Widhalm, Theresia; Wiklicky, Viktoria; Koller, Robert; Bonkowski, Michael; Lagerlöf, Jan; Ratzenböck, Andreas; Zaller, Johann G
2017-01-01
Seed dressing, i.e., the treatment of crop seeds with insecticides and/or fungicides, aiming to protect seeds from pests and diseases, is widely used in conventional agriculture. During the growing season, those crop fields often receive additional broadband herbicide applications. However, despite this broad utilization, very little is known on potential side effects or interactions between these different pesticide classes on soil organisms. In a greenhouse pot experiment, we studied single and interactive effects of seed dressing of winter wheat ( Triticum aestivum L. var. Capo ) with neonicotinoid insecticides and/or strobilurin and triazolinthione fungicides and an additional one-time application of a glyphosate-based herbicide on the activity of earthworms, soil microorganisms, litter decomposition, and crop growth. To further address food-web interactions, earthworms were introduced to half of the experimental units as an additional experimental factor. Seed dressings significantly reduced the surface activity of earthworms with no difference whether insecticides or fungicides were used. Moreover, seed dressing effects on earthworm activity were intensified by herbicides (significant herbicide × seed dressing interaction). Neither seed dressings nor herbicide application affected litter decomposition, soil basal respiration, microbial biomass, or specific respiration. Seed dressing did also not affect wheat growth. We conclude that interactive effects on soil biota and processes of different pesticide classes should receive more attention in ecotoxicological research.
Zaller, Johann G; König, Nina; Tiefenbacher, Alexandra; Muraoka, Yoko; Querner, Pascal; Ratzenböck, Andreas; Bonkowski, Michael; Koller, Robert
2016-08-17
Seed dressing with pesticides is widely used to protect crop seeds from pest insects and fungal diseases. While there is mounting evidence that especially neonicotinoid seed dressings detrimentally affect insect pollinators, surprisingly little is known on potential side effects on soil biota. We hypothesized that soil organisms would be particularly susceptible to pesticide seed dressings as they get in direct contact with these chemicals. Using microcosms with field soil we investigated, whether seeds treated either with neonicotinoid insecticides or fungicides influence the activity and interaction of earthworms, collembola, protozoa and microorganisms. The full-factorial design consisted of the factor Seed dressing (control vs. insecticide vs. fungicide), Earthworm (no earthworms vs. addition Lumbricus terrestris L.) and collembola (no collembola vs. addition Sinella curviseta Brook). We used commercially available wheat seed material (Triticum aesticum L. cf. Lukullus) at a recommended seeding density of 367 m(-2). Seed dressings (particularly fungicides) increased collembola surface activity, increased the number of protozoa and reduced plant decomposition rate but did not affect earthworm activity. Seed dressings had no influence on wheat growth. Earthworms interactively affected the influence of seed dressings on collembola activity, whereas collembola increased earthworm surface activity but reduced soil basal respiration. Earthworms also decreased wheat growth, reduced soil basal respiration and microbial biomass but increased soil water content and electrical conductivity. The reported non-target effects of seed dressings and their interactions with soil organisms are remarkable because they were observed after a one-time application of only 18 pesticide treated seeds per experimental pot. Because of the increasing use of seed dressing in agriculture and the fundamental role of soil organisms in agroecosystems these ecological interactions should receive more attention.
Arbitrary Dicke-State Control of Symmetric Rydberg Ensembles
NASA Astrophysics Data System (ADS)
Deutsch, Ivan
2017-04-01
We study the production of arbitrary superpositions of Dicke states via optimal control. We show that N atomic hyperfine qubits, interacting symmetrically via the Rydberg blockade, are well described by the Jaynes-Cummings Model (JCM), familiar in cavity QED. In this isomorphism, the presence or absence of a collective Rydberg excitation plays the role of the two-level system and the number of symmetric excitations of the hyperfine qubits plays the role of the bosonic excitations of the JCM. This system is fully controllable through the addition of phase-modulated microwaves that drive transitions between the Rydberg-dressed states. In the weak dressing regime, this results in a single-axis twisting Hamiltonian, plus time-dependent rotations of the collective spin. For strong dressing we control the entire Jaynes-Cummings ladder. Using optimal control, we design microwave waveforms that can generate arbitrary states in the symmetric subspace. This includes cat states, Dicke states, and spin squeezed states. With currently feasible parameters, it is possible to generate arbitrary symmetric states of _10 hyperfine qubits in 1 microsec, assuming a fast microwave phase switching time. The same control can be achieved with a ``dressed-ground control'' scheme, which reduces the demands for fast phase switching at the expense of increased total control time. More generally, we can achieve control on larger ensembles of qubits by designing waveforms that are bandwidth limited within the coherence time of the system. We use this to study general questions of the ``quantum speed limit'' and information content in a waveform that is needed to generate arbitrary quantum states.
Effect of magnon-phonon interactions on magnon squeezed states in ferromagnets
NASA Astrophysics Data System (ADS)
Mikhail, I. F. I.; Ismail, I. M. M.; Ameen, M.
2018-02-01
The squeezed states of dressed magnons in ferromagnets have been investigated. No effective Debye cutoff frequency has been assumed unlike what has been done hitherto. Instead, the results have been expressed throughout in terms of the reduced temperature. The effect of dressed magnon-phonon interactions on the formulation of these states has been studied. It has been shown that the magnon-phonon interactions play a significant role in determining the squeeze factor and the variation of the dressed magnon effective mass with temperature.
USDA-ARS?s Scientific Manuscript database
Understanding how wound dressings may be designed to address critical unsolved issues in wound repair and treatment influences the development of dressings and new concepts of promoting healing. The vast majority of commercial dressing materials focus on the physical aspects of wounds, e.g., acting ...
NASA Astrophysics Data System (ADS)
Zhang, Xu; Chen, Ye-Hong; Shi, Zhi-Cheng; Shan, Wu-Jiang; Song, Jie; Xia, Yan
2017-12-01
Combining the advantages of the dressed states and superconducting quantum interference device (SQUID) qubits, we propose an efficient scheme to generate Greenberger-Horne-Zeilinger (GHZ) states for three SQUID qubits. Firstly, we elaborate how to generate GHZ states of three SQUID qubits by choosing a set of dressed states suitably. Then, we compare the scheme by using dressed states with that via the adiabatic passage. Lastly, the influence of various decoherence factors, such as cavity decay, spontaneous emission and dephasing, is analyzed numerically. All of the results show that the GHZ state can be obtained fast and with high fidelity and that the present scheme is robust against the cavity decay and spontaneous emission. In addition, our scheme is more stable against the dephasing than the adiabatic scheme.
Aydogdu, Mehmet Onur; Altun, Esra; Crabbe-Mann, Maryam; Brako, Francis; Koc, Fatma; Ozen, Gunes; Kuruca, Serap Erdem; Edirisinghe, Ursula; Luo, C J; Gunduz, Oguzhan; Edirisinghe, Mohan
2018-05-27
Electrospun nanofibrous scaffolds are promising regenerative wound dressing options but have yet to be widely used in practice. The challenge is that nanofibre productions rely on bench-top apparatuses, and the delicate product integrity is hard to preserve before reaching the point of need. Timing is critically important to wound healing. The purpose of this investigation is to produce novel nanofibrous scaffolds using a portable, hand-held "gun", which enables production at the wound site in a time-dependent fashion, thereby preserving product integrity. We select bacterial cellulose, a natural hydrophilic biopolymer, and polycaprolactone, a synthetic hydrophobic polymer, to generate composite nanofibres that can tune the scaffold hydrophilicity, which strongly affects cell proliferation. Composite scaffolds made of 8 different ratios of bacterial cellulose and polycaprolactone were successfully electrospun. The morphological features and cell-scaffold interactions were analysed using scanning electron microscopy. The biocompatibility was studied using Saos-2 cell viability test. The scaffolds were found to show good biocompatibility and allow different proliferation rates that varied with the composition of the scaffolds. A nanofibrous dressing that can be accurately moulded and standardised via the portable technique is advantageous for wound healing in practicality and in its consistency through mass production. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Rydberg-Dressed Magneto-optical Trap
NASA Astrophysics Data System (ADS)
Bounds, A. D.; Jackson, N. C.; Hanley, R. K.; Faoro, R.; Bridge, E. M.; Huillery, P.; Jones, M. P. A.
2018-05-01
We propose and demonstrate the laser cooling and trapping of Rydberg-dressed Sr atoms. By off-resonantly coupling the excited state of a narrow (7 kHz) cooling transition to a high-lying Rydberg state, we transfer Rydberg properties such as enhanced electric polarizability to a stable magneto-optical trap operating at <1 μ K . Simulations show that it is possible to reach a regime where the long-range interaction between Rydberg-dressed atoms becomes comparable to the kinetic energy, opening a route to combining laser cooling with tunable long-range interactions.
Adiabatic Quantum Computing with Neutral Atoms
NASA Astrophysics Data System (ADS)
Hankin, Aaron; Biedermann, Grant; Burns, George; Jau, Yuan-Yu; Johnson, Cort; Kemme, Shanalyn; Landahl, Andrew; Mangan, Michael; Parazzoli, L. Paul; Schwindt, Peter; Armstrong, Darrell
2012-06-01
We are developing, both theoretically and experimentally, a neutral atom qubit approach to adiabatic quantum computation. Using our microfabricated diffractive optical elements, we plan to implement an array of optical traps for cesium atoms and use Rydberg-dressed ground states to provide a controlled atom-atom interaction. We will develop this experimental capability to generate a two-qubit adiabatic evolution aimed specifically toward demonstrating the two-qubit quadratic unconstrained binary optimization (QUBO) routine.
Dressing effects on the occurrence scattering time retardation and advance in a dusty plasma
NASA Astrophysics Data System (ADS)
Lee, Myoung-Jae; Jung, Young-Dae; Hanyang Plasma Team
2017-10-01
The dressing effects on the occurrence scattering time for the dust-dust interaction are investigated in a complex plasma. The first-order eikonal analysis is applied to obtain the scattering amplitude and the occurrence scattering time for the dust-dust interaction. The result shows that dressing effect enhances the retardation phenomena of the occurrence scattering time in the forward scattering domain. It is shown that the oscillatory behavior of the scaled occurrence scattering time is getting more significant with an increase of the Debye length. It is also found that the retardation domain of the occurrence scattering time increases with a decrease of the Debye length. The variation of the occurrence scattering time retardation and advance due to the dressing effect is also discussed.
NASA Astrophysics Data System (ADS)
Li, Xinghua; Zhang, Dan; Sun, Ming; Li, Kangkang; Wang, Zhiguo; Zhang, Yanpeng
2018-04-01
We study different dressing effects in parametrically amplified four-wave mixing (PA-FWM) processes. By seeding a weak probe laser into the Stokes or anti-Stokes channel of the FWM, the gain process is generated in the so-called bright twin beams which are the probe and conjugate beams. The dressing types dramatically affect the gain factors in both the probe and conjugate channels. The gain factor of the FWM signal decreases under the cascade-type dressing and the signal's shape splits into two dips under this dressing type. However, the intensity of the FWM signal changes from suppression to enhancement under the parallel-type dressing. We will apply this switching process to all-optical switching.
Wu, Jin-Lei; Ji, Xin; Zhang, Shou
2017-01-01
We propose a dressed-state scheme to achieve shortcuts to adiabaticity in atom-cavity quantum electrodynamics for speeding up adiabatic two-atom quantum state transfer and maximum entanglement generation. Compared with stimulated Raman adiabatic passage, the dressed-state scheme greatly shortens the operation time in a non-adiabatic way. By means of some numerical simulations, we determine the parameters which can guarantee the feasibility and efficiency both in theory and experiment. Besides, numerical simulations also show the scheme is robust against the variations in the parameters, atomic spontaneous emissions and the photon leakages from the cavity. PMID:28397793
Enhancing pressure ulcer prevention using wound dressings: what are the modes of action?
Call, Evan; Pedersen, Justin; Bill, Brian; Black, Joyce; Alves, Paulo; Brindle, C Tod; Dealey, Carol; Santamaria, Nick; Clark, Michael
2015-08-01
Recent clinical research has generated interest in the use of sacral wound dressings as preventive devices for patients at risk of ulceration. This study was conducted to identify the modes of action through which dressings can add to pressure ulcer prevention, for example, shear and friction force redistribution and pressure distribution. Bench testing was performed using nine commercially available dressings. The use of dressings can reduce the amplitude of shear stress and friction reaching the skin of patients at risk. They can also effectively redirect these forces to wider areas which minimises the mechanical loads upon skeletal prominences. Dressings can redistribute pressure based upon their effective Poisson ratio and larger deflection areas, providing greater load redistribution. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Spampinato, A.; Axinte, D. A.
2017-12-01
The mechanisms of interaction between bodies with statistically arranged features present characteristics common to different abrasive processes, such as dressing of abrasive tools. In contrast with the current empirical approach used to estimate the results of operations based on attritive interactions, the method we present in this paper allows us to predict the output forces and the topography of a simulated grinding wheel for a set of specific operational parameters (speed ratio and radial feed-rate), providing a thorough understanding of the complex mechanisms regulating these processes. In modelling the dressing mechanisms, the abrasive characteristics of both bodies (grain size, geometry, inter-space and protrusion) are first simulated; thus, their interaction is simulated in terms of grain collisions. Exploiting a specifically designed contact/impact evaluation algorithm, the model simulates the collisional effects of the dresser abrasives on the grinding wheel topography (grain fracture/break-out). The method has been tested for the case of a diamond rotary dresser, predicting output forces within less than 10% error and obtaining experimentally validated grinding wheel topographies. The study provides a fundamental understanding of the dressing operation, enabling the improvement of its performance in an industrial scenario, while being of general interest in modelling collision-based processes involving statistically distributed elements.
Aphasia and activities of daily living in stroke patients.
Gialanella, Bernardo; Prometti, Paola; Vanoglio, Fabio; Comini, Laura; Santoro, Raffaele
2016-12-01
Few studies have investigated the relationships between aphasia and activities of daily living (ADLs) in stroke patients. This study was aimed firstly to determine which task within the ADLs has poorer functional recovery in stroke patients with aphasia after rehabilitation, second to identify which specific task is related to aphasia. This is a prospective and observational study. Inpatients of our Rehabilitation Unit. The study was carried out in 219 patients with primary diagnosis of stroke with (104) and without aphasia (115). All patients underwent usual rehabilitation. Aachen Aphasia Test and Functional Independence Measure scale were used to assess severity of aphasia and ADLs, respectively. Gain in ADLs was the main outcome measure. At the end of rehabilitation patients with aphasia had lower gain in bathing, dressing upper body, dressing lower body, toileting, stair climbing, and higher gain in social interaction, problem solving, and memory with respect to patients without aphasia. However, when data were adjusted for side of hemiplegia, Fugl-Meyer score and trunk control test, patients with aphasia showed lower gain in dressing upper body (P=0.027), dressing lower body (P=0.009), lower toileting (P=0.027), and higher gain in social interaction (P<0.001). In the multivariate regression analysis, aphasia was an important determinant of gain in bathing (β=0.26), dressing upper body (β=0.24), dressing lower body (β=0.22), lower toileting (β=0.22), and social interaction (β=-0.29). The current study points out that, after usual rehabilitation, the patients with aphasia show a poor gain in personal care activities and higher gain in social interaction. Knowledge of these findings: 1) can guide the rehabilitation team in selecting specific and appropriate therapies aimed to give patient with aphasia the highest possible functional independence in ADLs; 2) is useful to family members and social rehabilitation services for domiciliary management of patients with aphasia.
Dressing control of biphoton waveform transitions
NASA Astrophysics Data System (ADS)
Li, Xinghua; Zhang, Dan; Zhang, Da; Hao, Ling; Chen, Haixia; Wang, Zhiguo; Zhang, Yanpeng
2018-05-01
We experimentally realize and theoretically analyze narrow-band biphotons generated in a hot rubidium vapor cell by four-wave-mixing processing. A dressing laser beam is used to alternate both linear and nonlinear susceptibilities of the vapor, thereby modifying the biphoton's temporal correlation function. Most notably, the correlation time is increased from 6 to 165 ns. The biphoton shape is also shown to change as a result of the coupled-states dressing. We observed Rabi oscillations and optical precursors in hot atomic vapor cells. We also theoretically simulated biphoton correlation times as influenced by dressing-laser detuning and power, the results of which are consistent with our experiments.
Davis, Stephen C; Li, Jie; Gil, Joel; Valdes, Jose; Solis, Michael; Higa, Alex; Bowler, Philip
2018-06-11
Topical antimicrobials are widely used to control wound bioburden and facilitate wound healing; however, the fine balance between antimicrobial efficacy and non-toxicity must be achieved. This study evaluated whether an anti-biofilm silver-containing wound dressing interfered with the normal healing process in non-contaminated deep partial thickness wounds. In an in-vivo porcine wound model using 2 pigs, 96 wounds were randomly assigned to 1 of 3 dressing groups: anti-biofilm silver Hydrofiber dressing (test), silver Hydrofiber dressing (control), or polyurethane film dressing (control). Wounds were investigated for 8 days, and wound biopsies (n = 4) were taken from each dressing group, per animal, on days 2, 4, 6, and 8 after wounding and evaluated using light microscopy. No statistically significant differences were observed in the rate of reepithelialisation, white blood cell infiltration, angiogenesis, or granulation tissue formation following application of the anti-biofilm silver Hydrofiber dressing versus the 2 control dressings. Overall, epithelial thickness was similar between groups. Some differences in infiltration of specific cell types were observed between groups. There were no signs of tissue necrosis, fibrosis, or fatty infiltration in any group. An anti-biofilm silver Hydrofiber wound dressing did not cause any notable interference with normal healing processes. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Cotton and Protein Interactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goheen, Steven C.; Edwards, J. V.; Rayburn, Alfred R.
The adsorbent properties of important wound fluid proteins and cotton cellulose are reviewed. This review focuses on the adsorption of albumin to cotton-based wound dressings and some chemically modified derivatives targeted for chronic wounds. Adsorption of elastase in the presence of albumin was examined as a model to understand the interactive properties of these wound fluid components with cotton fibers. In the chronic non-healing wound, elastase appears to be over-expressed, and it digests tissue and growth factors, interfering with the normal healing process. Albumin is the most prevalent protein in wound fluid, and in highly to moderately exudative wounds, itmore » may bind significantly to the fibers of wound dressings. Thus, the relative binding properties of both elastase and albumin to wound dressing fibers are of interest in the design of more effective wound dressings. The present work examines the binding of albumin to two different derivatives of cotton, and quantifies the elastase binding to the same derivatives following exposure of albumin to the fiber surface. An HPLC adsorption technique was employed coupled with a colorimetric enzyme assay to quantify the relative binding properties of albumin and elastase to cotton. The results of wound protein binding are discussed in relation to the porosity and surface chemistry interactions of cotton and wound proteins. Studies are directed to understanding the implications of protein adsorption phenomena in terms of fiber-protein models that have implications for rationally designing dressings for chronic wounds.« less
2014-04-01
The MSD is comprised of a syringe applicator filled with compressed chitosan coated sponges which are delivered into the wound at the site of the...transmitted effectively to the deep subclavian vessels to stop hemorrhage. As a result of their non-compressible nature and paucity of effective field...followed by three minutes of compression to the packed dressing. The mini- sponge dressing (MSD) is a novel product that utilizes compressed, chitosan
DEVELOPMENT OF A NEXT-GENERATION ANTIMICROBIAL WOUND DRESSING.
Metcalf, Daniel; Parsons, David; Bowler, I Philip
2016-03-01
Delayed wound healing due to infection is a burden on healthcare systems, and the patient and caregiver alike. An emerging factor in infection and delayed healing is the presence development of biofilm in wounds. Biofilm is communities of microorganisms, protected by an extracellular matrix of slime in the wound, which can tolerate host defences and applied antimicrobials such as antibiotics or antimicrobial dressings. A growing evidence base exists suggesting that biofilm exists in a majority of chronic wounds, and can be a precursor to infection while causing delayed healing itself. In vivo models have demonstrated that the inflammatory, granulation and epithelialization processes of normal wound healing are impaired by biofilm presence. The challenge in the development of a new antimicrobial wound dressing was to make standard antimicrobial agents more effective against biofilm, and this was answered following extensive biofilm research and testing. A combination of metal chelator, surfactant and pH control displayed highly synergistic anti-biofilm action with 1.2% ionic silver in a carboxymethylcellulose dressing. Its effectiveness was challenged and proven in complex in vitro and in vivo wound biofilm models, followed by clinical safety and performance demonstrations in a 42-patient study and 113 clinical evaluations. Post-market surveillance was conducted on the commercially available dressing, and in a 112-case evaluation, the dressing was shown to effectively manage exudate and suspected biofilm while shifting difficult-to-heal wounds onto healing trajectories, after an average of 4 weeks of new dressing use in otherwise standard wound care protocols. This was accompanied by a low frequency of dressing related adverse events. In a second evaluation, clinical signs of infection and wound dimension data, before and after the evaluations, were also available. Following an average of 5.4 weeks of dressing use, all signs of clinical infection were reduced, from an average frequency of 36% to 21%. An average of 62% wound size reduction was achieved, with 90% of wounds reducing in size and 10 wounds healing completely. The new clinical evidence for this next-generation antimicrobial wound dressing suggests it is safe and effective at managing exudate, infection and biofilm, while it can shift established, stubborn wounds onto healing trajectories. The scientific rationale for this new dressing technology is supported by in vitro and in vivo evidence, so now further comparative, randomized and outcome-based clinical studies are required to fully understand the clinical and economic benefits this new dressing technology can bring.
NASA Astrophysics Data System (ADS)
Kampeerapappun, Piyaporn
In general, a dressing is used to protect and help heal wounds. There are several types of dressings on the market such as hydrocolloid, hydrogel, and medicated dressings. One technique for making a dressing is electrospinning, which is a very simple procedure used to produce fibers. Due to much smaller fiber-diameters than produced with the conventional technique, the fibers from electrospinning have unique properties: high porosity and high surface areas, which are advantageous for wound healing. In this research, the fibers were electrospun using polyurethane, TecophilicRTM or TecoflexRTM, with various additives. First, multilayer transdermal electrospun dressings, four and five-layers, were developed that allowed for the controlled release of nitric oxide (NO) from a NO2 -/ascorbic acid system encapsulated in polymer nanofibers. The amount of NO released from each wound dressing was investigated. Both the four and five-layer dressings were tested for morphology of fibers, water absorption, nitrite distribution, NO release profile after sterilization by gamma radiation, and stability. In the case of the four-layer transdermal dressing, the dressing was tested in diabetic, periodontal, and cutaneous leishmaniasis patients. Furthermore, the color change of dressing was investigated. TecophilicRTM was also spun with an antimicrobial agent, which was added to the TecophilicRTM solution to electrospin an antimicrobial dressing. The morphology of fibers was tested using an optical microscope and the water absorption, uniformity, and percent extraction of dressing were also determined. In addition, the efficiency of the antimicrobial agent in the dressing was determined according to SN 195920-1994 and ASTM 2149-01. Another NO-releasing dressing was developed employing the NO donor molecules, sodium salt of linear polyethylenimine NONOates (LPEINO-Na) and calcium salt of linear polyethylenimine NONOates (LPEINO-Ca), which were electrospun with TecophilicRTM. The NO release profiles for the LPEINO fibers were generated using a nitric oxide analyzer (NOA) and distribution of the particles in the dressing was examined. Moreover, the amount of NO released after patch storage for 1 and 2 months was determined.
Plasma treatments of dressings for wound healing: a review.
Eswaramoorthy, Nithya; McKenzie, David R
2017-12-01
This review covers the use of plasma technology relevant to the preparation of dressings for wound healing. The current state of knowledge of plasma treatments that have potential to provide enhanced functional surfaces for rapid and effective healing is summarized. Dressings that are specialized to the needs of individual cases of chronic wounds such as diabetic ulcers are a special focus. A summary of the biology of wound healing and a discussion of the various types of plasmas that are suitable for the customizing of wound dressings are given. Plasma treatment allows the surface energy and air permeability of the dressing to be controlled, to ensure optimum interaction with the wound. Plasmas also provide control over the surface chemistry and in cases where the plasma creates energetic ion bombardment, activation with long-lived radicals that can bind therapeutic molecules covalently to the surface of the dressing. Therapeutic innovations enabled by plasma treatment include the attachment of microRNA or antimicrobial peptides. Bioactive molecules that promote subsequent cell adhesion and proliferation can also be bound, leading to the recruitment of cells to the dressing that may be stem cells or patient-derived cells. The presence of a communicating cell population expressing factors promotes healing.
The effect of semirigid dressings on below-knee amputations.
MacLean, N; Fick, G H
1994-07-01
The effect of using semirigid dressings (SRDs) on the residual limb of individuals who have had below-knee amputations as a consequence of peripheral vascular disease was investigated, with the primary question being: Does the time to readiness for prosthetic fitting for patients treated with the SRDs differ from that of patients treated with soft dressings? Forty patients entered the study and were alternately assigned to one of two groups. Nineteen patients were assigned to the SRD group, and 21 patients were assigned to the soft dressing group. The time from surgery to readiness for prosthetic fitting was recorded for each patient. Kaplan-Meier survival curves were generated for each group, and the results were analyzed with the log-rank test. There was a difference between the two curves, and an examination of the curves suggests that the expected time to readiness for prosthetic fitting for patients treated with the SRDs would be less than half that of patients treated with soft dressings. The results suggest that a patient may be ready for prosthetic fitting sooner if treated with SRDs instead of soft dressings.
Quantum ring with the Rashba spin-orbit interaction in the regime of strong light-matter coupling
NASA Astrophysics Data System (ADS)
Kozin, V. K.; Iorsh, I. V.; Kibis, O. V.; Shelykh, I. A.
2018-04-01
We developed the theory of electronic properties of semiconductor quantum rings with the Rashba spin-orbit interaction irradiated by an off-resonant high-frequency electromagnetic field (dressing field). Within the Floquet theory of periodically driven quantum systems, it is demonstrated that the dressing field drastically modifies all electronic characteristics of the rings, including spin-orbit coupling, effective electron mass, and optical response. In particular, the present effect paves the way to controlling the spin polarization of electrons with light in prospective ring-shaped spintronic devices.
Cattelan, Marília Gonçalves; Nishiyama, Yara Paula de Oliveira; Gonçalves, Tânia Maria Vinturim; Coelho, Alexandre Rodrigo
2018-08-01
There is a broad research interest in the search for alternatives to chemical additives for use as natural food preservatives. Although many natural compounds have biological in vitro properties evidenced, in situ studies are still scarce. This study evaluated the effect of oregano essential oil (OEO) and salt (NaCl) concentrations against Escherichia coli (ATCC 8739), in salad dressing, using the response surface methodology. The experiment included a 2 2 central composite rotatable design (CCRD) in a total of 11 formulations of salad dressings. Oregano essential oil was characterized by gas chromatography and salad dressings by ash, lipids, proteins and moisture. OEO was composed mainly by carvacrol (65.1%) and p-cymene (12.0%). Salad dressings showed similar chemical profiles. A mathematical model for the prediction of the antibacterial activity in salad dressing was obtained. The results revealed that the interaction between OEO and salt showed effect on the bacterial count. However, the effect of salt was negative suggesting that the highest NaCl concentrations decreases the bacterial count. Therefore, within the parameters studied, the use of OEO to control E. coli in salad dressing can be considered promising and allows reduction in the levels of salt to be incorporated in food. Copyright © 2018 Elsevier Ltd. All rights reserved.
Synthetic clock states generated in a Bose-Einstein condensate via continuous dynamical decoupling
NASA Astrophysics Data System (ADS)
Lundblad, Nathan; Trypogeorgos, Dimitrios; Valdes-Curiel, Ana; Marshall, Erin; Spielman, Ian
2017-04-01
Radiofrequency- or microwave-dressed states have been used in NV center and ion-trap experiments to extend coherence times, shielding qubits from magnetic field noise through a process known as continuous dynamical decoupling. Such field-insensitive dressed states, as applied in the context of ultracold neutral atoms, have applications related to the creation of novel phases of spin-orbit-coupled quantum matter. We present observations of such a protected dressed-state system in a Bose-Einstein condensate, including measurements of the dependence of the protection on rf coupling strength, and estimates of residual field sensitivities.
A new approach to entangling neutral atoms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jongmin; Martin, Michael J.; Jau, Yuan-Yu
2016-11-01
Our team has developed a new approach to entangling neutral atoms with a Rydberg-dressed interaction. Entangling neutral atoms is an essential key of quantum technologies such as quantum computation, many-body quantum simulation, and high-precision atomic sensors . The demonstrated Rydberg-dressed protocol involves adiabatically imposing a light shift on the ground state by coupling an excited Rydberg state with a tuned laser field. Using this technique, we have demonstrated a strong and tunable dipole - dipole interaction between two individually trapped atoms with energy shifts of order 1 MHz, which has been challenging to achieve in other protocols . During thismore » program, we experimentally demonstrated Bell-state entanglement and the isomorphism to the Jaynes - Cumming model of a Rydberg-dressed two-atom system. Our theoretical calculations of a CPHASE quantum logic gate and arbitrary Dicke state quantum control in this system encourage further work.« less
A neuron-astrocyte transistor-like model for neuromorphic dressed neurons.
Valenza, G; Pioggia, G; Armato, A; Ferro, M; Scilingo, E P; De Rossi, D
2011-09-01
Experimental evidences on the role of the synaptic glia as an active partner together with the bold synapse in neuronal signaling and dynamics of neural tissue strongly suggest to investigate on a more realistic neuron-glia model for better understanding human brain processing. Among the glial cells, the astrocytes play a crucial role in the tripartite synapsis, i.e. the dressed neuron. A well-known two-way astrocyte-neuron interaction can be found in the literature, completely revising the purely supportive role for the glia. The aim of this study is to provide a computationally efficient model for neuron-glia interaction. The neuron-glia interactions were simulated by implementing the Li-Rinzel model for an astrocyte and the Izhikevich model for a neuron. Assuming the dressed neuron dynamics similar to the nonlinear input-output characteristics of a bipolar junction transistor, we derived our computationally efficient model. This model may represent the fundamental computational unit for the development of real-time artificial neuron-glia networks opening new perspectives in pattern recognition systems and in brain neurophysiology. Copyright © 2011 Elsevier Ltd. All rights reserved.
Hämmerle, Gilbert; Strohal, Robert
2016-04-01
The aim of this study was to determine the efficacy, safety and cost-effectiveness of an octenidine-based wound gel in the treatment of chronic venous leg ulcers. For this purpose, 49 wounds were treated with either modern wound-phase-adapted dressings alone (treatment arm 1; n = 17), octenidine wound gel plus modern wound-phase-adapted dressings (treatment arm 2; n = 17) or octenidine wound gel alone (treatment arm 3; n = 15). During the study period of 42 days with dressing changes every 3-5 days, wound healing characteristics and treatment costs of different dressings were analysed. Wound size reduction was significantly better (P = 0·028) in both octenidine wound gel treatment arms compared to modern dressings alone with total reductions of 14·6%, 64·1% and 96·2% in treatment arms 1-3. Early wound healing was merely observed under octenidine wound gel treatment (n = 9), whereby lowest treatment costs were generated by octenidine wound gel alone (€20·34/dressing change). As a result, the octenidine wound gel is cost-effective and well suitable for the treatment of chronic venous leg ulcers, considering both safety and promotion of wound healing. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Many-body interferometry of magnetic polaron dynamics
NASA Astrophysics Data System (ADS)
Ashida, Yuto; Schmidt, Richard; Tarruell, Leticia; Demler, Eugene
2018-02-01
The physics of quantum impurities coupled to a many-body environment is among the most important paradigms of condensed-matter physics. In particular, the formation of polarons, quasiparticles dressed by the polarization cloud, is key to the understanding of transport, optical response, and induced interactions in a variety of materials. Despite recent remarkable developments in ultracold atoms and solid-state materials, the direct measurement of their ultimate building block, the polaron cloud, has remained a fundamental challenge. We propose and analyze a platform to probe time-resolved dynamics of polaron-cloud formation with an interferometric protocol. We consider an impurity atom immersed in a two-component Bose-Einstein condensate where the impurity generates spin-wave excitations that can be directly measured by the Ramsey interference of surrounding atoms. The dressing by spin waves leads to the formation of magnetic polarons and reveals a unique interplay between few- and many-body physics that is signified by single- and multi-frequency oscillatory dynamics corresponding to the formation of many-body bound states. Finally, we discuss concrete experimental implementations in ultracold atoms.
Adiabatic quantum computation with neutral atoms via the Rydberg blockade
NASA Astrophysics Data System (ADS)
Goyal, Krittika; Deutsch, Ivan
2011-05-01
We study a trapped-neutral-atom implementation of the adiabatic model of quantum computation whereby the Hamiltonian of a set of interacting qubits is changed adiabatically so that its ground state evolves to the desired output of the algorithm. We employ the ``Rydberg blockade interaction,'' which previously has been used to implement two-qubit entangling gates in the quantum circuit model. Here it is employed via off-resonant virtual dressing of the excited levels, so that atoms always remain in the ground state. The resulting dressed-Rydberg interaction is insensitive to the distance between the atoms within a certain blockade radius, making this process robust to temperature and vibrational fluctuations. Single qubit interactions are implemented with global microwaves and atoms are locally addressed with light shifts. With these ingredients, we study a protocol to implement the two-qubit Quadratic Unconstrained Binary Optimization (QUBO) problem. We model atom trapping, addressing, coherent evolution, and decoherence. We also explore collective control of the many-atom system and generalize the QUBO problem to multiple qubits. We study a trapped-neutral-atom implementation of the adiabatic model of quantum computation whereby the Hamiltonian of a set of interacting qubits is changed adiabatically so that its ground state evolves to the desired output of the algorithm. We employ the ``Rydberg blockade interaction,'' which previously has been used to implement two-qubit entangling gates in the quantum circuit model. Here it is employed via off-resonant virtual dressing of the excited levels, so that atoms always remain in the ground state. The resulting dressed-Rydberg interaction is insensitive to the distance between the atoms within a certain blockade radius, making this process robust to temperature and vibrational fluctuations. Single qubit interactions are implemented with global microwaves and atoms are locally addressed with light shifts. With these ingredients, we study a protocol to implement the two-qubit Quadratic Unconstrained Binary Optimization (QUBO) problem. We model atom trapping, addressing, coherent evolution, and decoherence. We also explore collective control of the many-atom system and generalize the QUBO problem to multiple qubits. We acknowledge funding from the AQUARIUS project, Sandia National Laboratories
Fontenot, Krystal R; Edwards, J Vincent; Haldane, David; Pircher, Nicole; Liebner, Falk; Condon, Brian D; Qureshi, Huzaifah; Yager, Dorne
2017-11-01
Interfacing nanocellulosic-based biosensors with chronic wound dressings for protease point of care diagnostics combines functional material properties of high specific surface area, appropriate surface charge, and hydrophilicity with biocompatibility to the wound environment. Combining a protease sensor with a dressing is consistent with the concept of an intelligent dressing, which has been a goal of wound-dressing design for more than a quarter century. We present here biosensors with a nanocellulosic transducer surface (nanocrystals, nanocellulose composites, and nanocellulosic aerogels) immobilized with a fluorescent elastase tripeptide or tetrapeptide biomolecule, which has selectivity and affinity for human neutrophil elastase present in chronic wound fluid. The specific surface area of the materials correlates with a greater loading of the elastase peptide substrate. Nitrogen adsorption and mercury intrusion studies revealed gas permeable systems with different porosities (28-98%) and pore sizes (2-50 nm, 210 µm) respectively, which influence water vapor transmission rates. A correlation between zeta potential values and the degree of protease sequestration imply that the greater the negative surface charge of the nanomaterials, the greater the sequestration of positively charged neutrophil proteases. The biosensors gave detection sensitivities of 0.015-0.13 units/ml, which are at detectable human neutrophil elastase levels present in chronic wound fluid. Thus, the physical and interactive biochemical properties of the nano-based biosensors are suitable for interfacing with protease sequestrant prototype wound dressings. A discussion of the relevance of protease sensors and cellulose nanomaterials to current chronic wound dressing design and technology is included.
Dressed Gain from the Parametrically Amplified Four-Wave Mixing Process in an Atomic Vapor.
Zhang, Zhaoyang; Wen, Feng; Che, Junling; Zhang, Dan; Li, Changbiao; Zhang, Yanpeng; Xiao, Min
2015-10-14
With a forward cone emitting from the strong pump laser in a thermal rubidium atomic vapor, we investigate the non-degenerate parametrically amplified four-wave mixing (PA-FWM) process with dressing effects in a three-level "double-Λ" configuration both theoretically and experimentally. By seeding a weak probe field into the Stokes or anti-Stokes channel of the FWM, the gain processes are generated in the bright twin beams which are called conjugate and probe beams, respectively. However, the strong dressing effect of the pump beam will dramatically affect the gain factors both in the probe and conjugate channels, and can inevitably impose an influence on the quantum effects such as entangled degree and the quantum noise reduction between the two channels. We systematically investigate the intensity evolution of the dressed gain processes by manipulating the atomic density, the Rabi frequency and the frequency detuning. Such dressing effects are also visually evidenced by the observation of Autler-Townes splitting of the gain peaks. The investigation can contribute to the development of quantum information processing and quantum communications.
Dressed Gain from the Parametrically Amplified Four-Wave Mixing Process in an Atomic Vapor
NASA Astrophysics Data System (ADS)
Zhang, Zhaoyang; Wen, Feng; Che, Junling; Zhang, Dan; Li, Changbiao; Zhang, Yanpeng; Xiao, Min
2015-10-01
With a forward cone emitting from the strong pump laser in a thermal rubidium atomic vapor, we investigate the non-degenerate parametrically amplified four-wave mixing (PA-FWM) process with dressing effects in a three-level “double-Λ” configuration both theoretically and experimentally. By seeding a weak probe field into the Stokes or anti-Stokes channel of the FWM, the gain processes are generated in the bright twin beams which are called conjugate and probe beams, respectively. However, the strong dressing effect of the pump beam will dramatically affect the gain factors both in the probe and conjugate channels, and can inevitably impose an influence on the quantum effects such as entangled degree and the quantum noise reduction between the two channels. We systematically investigate the intensity evolution of the dressed gain processes by manipulating the atomic density, the Rabi frequency and the frequency detuning. Such dressing effects are also visually evidenced by the observation of Autler-Townes splitting of the gain peaks. The investigation can contribute to the development of quantum information processing and quantum communications.
Sil, Soumitri; Dahlquist, Lynnda M; Burns, Andrew J
2013-04-01
This single-subject design study evaluated the feasibility and efficacy of passive and interactive videogame distraction on behavioral distress for a preschool-aged child receiving repeated burn dressing changes. A 4-year-old girl underwent 3 baseline and 10 videogame distraction sessions (5 passive and 5 interactive) using a restricted alternating treatments design. Observed behavioral distress was coded, and parents and nurses rated the child's distress and cooperative behavior. Relative to baseline, behavioral distress decreased and cooperative behavior increased immediately after the onset of videogame distraction. Single Case Randomization Tests revealed significantly lower behavioral distress and greater cooperation during interactive videogame distraction relative to passive videogame distraction. Interactive videogame distraction appears to be a feasible and effective pain management strategy for a preschool-aged child undergoing repeated painful medical procedures.
Valley-selective photon-dressed states in transition metal dichalcogenides
NASA Astrophysics Data System (ADS)
LaMountain, Trevor; Chen, Yen-Jung; Stanev, Teodor K.; Stern, Nathaniel P.
2018-02-01
When electronic excitations in a semiconductor interact with light, the relevant quasiparticles are hybrid lightmatter dressed states, or exciton-polaritons. In monolayer transition metal dichalcogenides, a class of 2D direct bandgap semiconductors, optical excitations selectively populate distinct momentum valleys with correlated spin projection. The combination of this spin-valley locking with photon dressed states can lead to new optical phenomena in these materials. We present spectroscopic measurements of valley-specific exciton-polaritons in monolayer 2D materials in distinct regimes. When a monolayer is embedded in a dielectric microcavity, strong coupling exciton-polaritons are achieved. Cavity-modified dynamics of the dressed states are inferred from emission. Polarization persists up to room temperature in monolayer MoS2, in contrast with bare material. We also show that distinct regimes of valley-polarized exciton-polaritons can be accessed with microcavity engineering by tuning system parameters such as cavity decay rate and exciton-photon coupling strength. Further, we report results showing that polarization-sensitive ultrafast spectroscopy can enable sensitive measurements of the valley optical Stark shift, a light-induced dressed state energy shift, in monolayer semiconductors such as WSe2 and MoS2. These findings demonstrate distinct approaches to manipulating the picosecond dynamics of valleysensitive dressed states in monolayer semiconductors.
Observation of the fluorescence spectrum for a driven cascade model system in atomic beam.
Tian, Si-Cong; Wang, Chun-Liang; Tong, Cun-Zhu; Wang, Li-Jun; Wang, Hai-Hua; Yang, Xiu-Bin; Kang, Zhi-Hui; Gao, Jin-Yue
2012-10-08
We experimentally study the resonance fluorescence from an excited two-level atom when the atomic upper level is coupled by a nonresonant field to a higher-lying state in a rubidium atomic beam. The heights, widths and positions of the fluorescence peaks can be controlled by modifying the detuning of the auxiliary field. We explain the observed spectrum with the transition properties of the dressed states generated by the coupling of the two laser fields. We also attribute the line narrowing to the effects of Spontaneously Generated Coherence between the close-lying levels in the dressed state picture generated by the auxiliary field. And the corresponding spectrum can be viewed as the evidence of Spontaneously Generated Coherence. The experimental results agree well with calculations based on the density-matrix equations.
Sil, Soumitri; Burns, Andrew J.
2013-01-01
Objective This single-subject design study evaluated the feasibility and efficacy of passive and interactive videogame distraction on behavioral distress for a preschool-aged child receiving repeated burn dressing changes. Method A 4-year-old girl underwent 3 baseline and 10 videogame distraction sessions (5 passive and 5 interactive) using a restricted alternating treatments design. Observed behavioral distress was coded, and parents and nurses rated the child’s distress and cooperative behavior. Results Relative to baseline, behavioral distress decreased and cooperative behavior increased immediately after the onset of videogame distraction. Single Case Randomization Tests revealed significantly lower behavioral distress and greater cooperation during interactive videogame distraction relative to passive videogame distraction. Conclusions Interactive videogame distraction appears to be a feasible and effective pain management strategy for a preschool-aged child undergoing repeated painful medical procedures. PMID:23248343
Exotic topological density waves in cold atomic Rydberg-dressed fermions
Li, Xiaopeng; Sarma, S Das
2015-01-01
Versatile controllability of interactions in ultracold atomic and molecular gases has now reached an era where quantum correlations and unconventional many-body phases can be studied with no corresponding analogues in solid-state systems. Recent experiments in Rydberg atomic gases have achieved exquisite control over non-local interactions, allowing novel quantum phases unreachable with the usual local interactions in atomic systems. Here we study Rydberg-dressed atomic fermions in a three-dimensional optical lattice predicting the existence of hitherto unheard-of exotic mixed topological density wave phases. By varying the spatial range of the non-local interaction, we find various chiral density waves with spontaneous time-reversal symmetry breaking, whose quasiparticles form three-dimensional quantum Hall and Weyl semimetal states. Remarkably, certain density waves even exhibit mixed topologies beyond the existing topological classification. Our results suggest gapless fermionic states could exhibit far richer topology than previously expected. PMID:25972134
All-optical band engineering of gapped Dirac materials
NASA Astrophysics Data System (ADS)
Kibis, O. V.; Dini, K.; Iorsh, I. V.; Shelykh, I. A.
2017-03-01
We demonstrate theoretically that the interaction of electrons in gapped Dirac materials (gapped graphene and transition-metal dichalchogenide monolayers) with a strong off-resonant electromagnetic field (dressing field) substantially renormalizes the band gaps and the spin-orbit splitting. Moreover, the renormalized electronic parameters drastically depend on the field polarization. Namely, a linearly polarized dressing field always decreases the band gap (and, particularly, can turn the gap into zero), whereas a circularly polarized field breaks the equivalence of valleys in different points of the Brillouin zone and can both increase and decrease corresponding band gaps. As a consequence, the dressing field can serve as an effective tool to control spin and valley properties of the materials and be potentially exploited in optoelectronic applications.
Atom-field dressed states in slow-light waveguide QED
NASA Astrophysics Data System (ADS)
Calajó, Giuseppe; Ciccarello, Francesco; Chang, Darrick; Rabl, Peter
2016-03-01
We discuss the properties of atom-photon bound states in waveguide QED systems consisting of single or multiple atoms coupled strongly to a finite-bandwidth photonic channel. Such bound states are formed by an atom and a localized photonic excitation and represent the continuum analog of the familiar dressed states in single-mode cavity QED. Here we present a detailed analysis of the linear and nonlinear spectral features associated with single- and multiphoton dressed states and show how the formation of bound states affects the waveguide-mediated dipole-dipole interactions between separated atoms. Our results provide both a qualitative and quantitative description of the essential strong-coupling processes in waveguide QED systems, which are currently being developed in the optical and microwave regimes.
Chiral-symmetry breaking and confinement in Minkowski space
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biernat, Elmer P.; Pena, M. T.; Ribiero, J. E.
2016-01-01
We present a model for the quark-antiquark interaction formulated in Minkowski space using the Covariant Spectator Theory. The quark propagators are dressed with the same kernel that describes the interaction between different quarks. By applying the axial-vector Ward-Takahashi identity we show that our model satisfies the Adler-zero constraint imposed by chiral symmetry. For this model, our Minkowski-space results of the dressed quark mass function are compared to lattice QCD data obtained in Euclidean space. The mass function is then used in the calculation of the electromagnetic pion form factor in relativistic impulse approximation, and the results are presented and comparedmore » with the experimental data from JLab.« less
Chiral-symmetry breaking and confinement in Minkowski space
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biernat, Elmar P.; Peña, M. T.; Departamento de Física, Instituto Superior Técnico
2016-01-22
We present a model for the quark-antiquark interaction formulated in Minkowski space using the Covariant Spectator Theory. The quark propagators are dressed with the same kernel that describes the interaction between different quarks. By applying the axial-vector Ward-Takahashi identity we show that our model satisfies the Adler-zero constraint imposed by chiral symmetry. For this model, our Minkowski-space results of the dressed quark mass function are compared to lattice QCD data obtained in Euclidean space. The mass function is then used in the calculation of the electromagnetic pion form factor in relativistic impulse approximation, and the results are presented and comparedmore » with the experimental data from JLab.« less
Towards a controlled-phase gate using Rydberg-dressed atoms
NASA Astrophysics Data System (ADS)
Hankin, Aaron; Jau, Yuan-Yu; Biedermann, Grant
2014-05-01
We are implementing a controlled-phase gate based on singly trapped neutral atoms whose coupling is mediated by the dipole-dipole interaction of Rydberg states. An off-resonant laser field dresses ground state cesium atoms in a manner conditional on the Rydberg blockade mechanism, providing the required entangling interaction. We will present our progress toward implementing the controlled-phase gate with an analysis of possible sources of decoherence such as RF radiation from wireless communication devices. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Triple tailored nonlinear dispersion of dressed four- and six-wave mixing
NASA Astrophysics Data System (ADS)
Sun, Yanyong; Wang, Zhiguo; Zhang, Zhaoyang; Gu, Bingling; Wang, Kun; Yang, Gaoguo; Zhang, Yanpeng
2018-06-01
We investigate the spectral signals and spatial images of a probe transmission signal, four-wave mixing (FWM), and six-wave mixing (SWM) under double dressing effects in an inverted Y-type system. Especially, we get the triple tailored nonlinear dispersion (about 60 MHz) of the dressed FWM and SWM through the interaction between electromagnetically induced transparency (EIT) windows and the Kerr nonlinearity. Moreover, SWM and dressed FWM with narrow linewidth are obtained through the tailoring of the three EIT windows, which is much narrower than the EIT. In addition, we first elaborate the modulation effect from the self-Kerr coefficient of FWM on the spot. We also investigate the spatial characteristics (defocusing, shifting, and splitting) of FWM and SWM induced by tailored self-Kerr and cross-Kerr effects among the relative fields. Such spatial shifting, splitting induced by the tailored nonlinear dispersion can be used for a higher contrast and high speed switch as well as a high resolution router.
Dhand, Chetna; Venkatesh, Mayandi; Barathi, Veluchami Amutha; Harini, Sriram; Bairagi, Samiran; Goh Tze Leng, Eunice; Muruganandham, Nandhakumar; Low, Kenny Zhi Wei; Fazil, Mobashar Hussain Urf Turabe; Loh, Xian Jun; Srinivasan, Dinesh Kumar; Liu, Shou Ping; Beuerman, Roger W; Verma, Navin Kumar; Ramakrishna, Seeram; Lakshminarayanan, Rajamani
2017-09-01
There is a growing demand for durable advanced wound dressings for the management of persistent infections after deep burn injuries. Herein, we demonstrated the preparation of durable antimicrobial nanofiber mats, by taking advantage of strong interfacial interactions between polyhydroxy antibiotics (with varying number of OH groups) and gelatin and their in-situ crosslinking with polydopamine (pDA) using ammonium carbonate diffusion method. Polydopamine crosslinking did not interfere with the antimicrobial efficacy of the loaded antibiotics. Interestingly, incorporation of antibiotics containing more number of alcoholic OH groups (N OH ≥ 5) delayed the release kinetics with complete retention of antimicrobial activity for an extended period of time (20 days). The antimicrobials-loaded mats displayed superior mechanical and thermal properties than gelatin or pDA-crosslinked gelatin mats. Mats containing polyhydroxy antifungals showed enhanced aqueous stability and retained nanofibrous morphology under aqueous environment for more than 4 weeks. This approach can be expanded to produce mats with broad spectrum antimicrobial properties by incorporating the combination of antibacterial and antifungal drugs. Direct electrospinning of vancomycin-loaded electrospun nanofibers onto a bandage gauze and subsequent crosslinking produced non-adherent durable advanced wound dressings that could be easily applied to the injured sites and readily detached after treatment. In a partial thickness burn injury model in piglets, the drug-loaded mats displayed comparable wound closure to commercially available silver-based dressings. This prototype wound dressing designed for easy handling and with long-lasting antimicrobial properties represents an effective option for treating life-threatening microbial infections due to thermal injuries. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Fano Interference in Classical Oscillators
ERIC Educational Resources Information Center
Satpathy, S.; Roy, A.; Mohapatra, A.
2012-01-01
We seek to illustrate Fano interference in a classical coupled oscillator by using classical analogues of the atom-laser interaction. We present an analogy between the dressed state picture of coherent atom-laser interaction and a classical coupled oscillator. The Autler-Townes splitting due to the atom-laser interaction is analogous to the…
Noise squeezing of fields that bichromatically excite atoms in a cavity.
Li, Lingchao; Hu, Xiangming; Rao, Shi; Xu, Jun
2016-11-14
It is well known that bichromatic excitation on one common transition can tune the emission or absorption spectra of atoms due to the modulation frequency dependent non-linearities. However little attention has been focused on the quantum dynamics of fields under bichromatic excitation. Here we present dissipative effects on noise correlations of fields in bichromatic interactions with atoms in cavities. We first consider an ensemble of two-level atoms that interacts with the two cavity fields of different frequencies and considerable amplitudes. By transferring the atom-field nonlinearities to the dressed atoms we separate out the dissipative interactions of Bogoliubov modes with the dressed atoms. The Bogoliubov mode dissipation establishes stable two-photon processes of two involved fields and therefore leads to two-mode squeezing. As a generalization, we then consider an ensemble of three-level Λ atoms for cascade bichromatic interactions. We extract the Bogoliubov-like four-mode interactions, which establish a quadrilateral of the two-photon processes of four involved fields and thus result in four-mode squeezing.
Held, Manuel; Engelke, Anne-Sophie; Tolzmann, Dascha Sophie; Rahmanian-Schwarz, Afshin; Schaller, Hans-Eberhard; Rothenberger, Jens
2016-09-01
There is a high prevalence of superficial wounds such as partial-thickness burns. Treatment of these wounds frequently includes temporary application of wound dressings. The aim of this study was to compare a newly developed collagen matrix with commonly used temporary skin dressings for treatment of partial-thickness skin defects. Through a skin dermatome, 42 standardized superficial skin defects were generated on the back of 28 adult male Lewis rats. The wounds were treated with a synthetic wound dressing (Suprathel, Polymedics Innovations Inc, Woodstock, GA) (n = 14), a biosynthetic skin dressing (Biobrane, Smith & Nephew, Hull, UK) (n = 14), or a newly developed bovine collagen matrix, Collagen Cell Carrier (Viscofan BioEngineering, Weinheim, Germany) (n = 14). Biomechanical properties of the skin were determined and compared every 10 days over a 3-month period of using the Cutometer MPA 580 (Courage + Khazaka Electronic GmbH, Cologne, Germany). As opposed to healthy skin, statistically significant differences were detected between days 10 and 30, and between days 60 and 80, for calculated elasticity (Ue), firmness of skin (R0), and overall elasticity (R8). After 3 months, no statistically significant differences in skin elasticity were detected between the different wound dressings. The presented results give an opportunity to compare the wound dressings used for treatment with respect to skin elasticity and reveal the potential of the bovine collagen matrix in the treatment of superficial skin defects; therefore the results facilitate further evaluation of collagen matrix in surgical applications and regenerative medicine.
A telemedicine wound care model using 4G with smart phones or smart glasses
Ye, Junna; Zuo, Yanhai; Xie, Ting; Wu, Minjie; Ni, Pengwen; Kang, Yutian; Yu, Xiaoping; Sun, Xiaofang; Huang, Yao; Lu, Shuliang
2016-01-01
Abstract To assess the feasibility of a wound care model using 4th-generation mobile communication technology standards (4G) with smart phones or smart glasses for wound management. This wound care model is an interactive, real-time platform for implementing telemedicine changing wound dressings, or doing operations. It was set up in March 2015 between Jinhua in Zhejiang province and Shanghai, China, which are 328 km apart. It comprised of a video application (APP), 4G net, smart phones or smart glasses, and a central server. This model service has been used in 30 patients with wounds on their lower extremities for 109 times in 1 month. Following a short learning curve, the service worked well and was deemed to be user-friendly. Two (6.7%) patients had wounds healed, while others still required wound dressing changes after the study finished. Both local surgeons and patients showed good acceptance of this model (100% and 83.33%, respectively). This telemedicine model is feasible and valuable because it provides an opportunity of medical service about wound healing in remote areas where specialists are scarce. PMID:27495023
Naruse, Koji; Uchino, Masataka; Hirakawa, Noriko; Toyama, Masahiro; Miyajima, Genyo; Mukai, Manabu; Urabe, Ken; Uchida, Kentaro; Itoman, Moritoshi
2016-08-01
We have conducted a basic study on the influences on ultrasonic properties when LIPUS is applied through wound dressing. According to the results of ex vivo experiments conducted to date, LIPUS showed ultrasonic properties such as transmittance, coefficient of transmission, and a non-uniformity ratio through film wound dressing better than other wound dressing, and it was considered that LIPUS's effect for fracture healing was not influenced by film wound dressing. Then, we discussed the influence on the effect of LIPUS through film wound dressing. Thirty male 8-week-old Sprague-Dawley rats were used for the trial. After creating close transverse femoral fractures on the right legs of these 30 rats, they were divided into 3 groups of 10; LIPUS through wound dressing (Group A), LIPUS without wound dressing (Group B), and No LIPUS treatment (Group C). OPSITE Wound, which was thought to have the least influence on ultrasound properties, was used for this trial. Group A and B received LIPUS for 20 minutes a day from the first day after the fractures. LIPUS was generated from Teijin Pharma's device for a basic experiment. When treating Group A, the wound dressing was pasted on the ultrasound terminal in order to apply LIPUS through the dressing. We assessed the time-oriented morphological change of each group in anesthetized condition using simple radiographs on the 8th, 16th, and 24th day after the fractures. Six rats in Group A, 2 in Group B, and 1 in Group C died in anesthesia, and we discussed the remaining 4 rats in Group A, 8 in Group B, and 9 in Group C. We defined more than one teleost callus bridging as bone-union. We also counted a bone remodeling when we recognized the absorption of existing cortical bone and the transformation of new bone to cortical bone in simple radiographs. As a result, compared with Group C, we recognized that both bone union and remodeling accelerated remarkably in Group B, but not in Group A. It suggested that LIPUS through wound dressing had negative influences on both period shorting of fracture healing and bone remodeling. When LIPUS was conducted through film wound dressing, transmittance and coefficient of transmission were unchanged; however, the non-uniformity ratio changed slightly. The non-uniformity ratio of the ultrasound transducer had a significant influence on the effect of LIPUS on fracture healing.
Features and flaws of a contact interaction treatment of the kaon
NASA Astrophysics Data System (ADS)
Chen, Chen; Chang, Lei; Roberts, Craig D.; Schmidt, Sebastian M.; Wan, Shaolong; Wilson, David J.
2013-04-01
Elastic and semileptonic transition form factors for the kaon and pion are calculated using the leading order in a global-symmetry-preserving truncation of the Dyson-Schwinger equations and a momentum-independent form for the associated kernels in the gap and Bethe-Salpeter equations. The computed form factors are compared both with those obtained using the same truncation but an interaction that preserves the one-loop renormalization-group behavior of QCD and with data. The comparisons show that in connection with observables revealed by probes with |Q2|≲M2, where M≈0.4GeV is an infrared value of the dressed-quark mass, results obtained using a symmetry-preserving regularization of the contact interaction are not realistically distinguishable from those produced by more sophisticated kernels, and available data on kaon form factors do not extend into the domain whereupon one could distinguish among the interactions. The situation differs if one includes the domain Q2>M2. Thereupon, a fully consistent treatment of the contact interaction produces form factors that are typically harder than those obtained with QCD renormalization-group-improved kernels. Among other things also described are a Ward identity for the inhomogeneous scalar vertex, similarity between the charge distribution of a dressed u quark in the K+ and that of the dressed u quark in the π+, and reflections upon the point whereat one might begin to see perturbative behavior in the pion form factor. Interpolations of the form factors are provided, which should assist in working to chart the interaction between light quarks by explicating the impact on hadron properties of differing assumptions about the behavior of the Bethe-Salpeter kernel.
Method and apparatus for quantum information processing using entangled neutral-atom qubits
Jau, Yuan Yu; Biedermann, Grant; Deutsch, Ivan
2018-04-03
A method for preparing an entangled quantum state of an atomic ensemble is provided. The method includes loading each atom of the atomic ensemble into a respective optical trap; placing each atom of the atomic ensemble into a same first atomic quantum state by impingement of pump radiation; approaching the atoms of the atomic ensemble to within a dipole-dipole interaction length of each other; Rydberg-dressing the atomic ensemble; during the Rydberg-dressing operation, exciting the atomic ensemble with a Raman pulse tuned to stimulate a ground-state hyperfine transition from the first atomic quantum state to a second atomic quantum state; and separating the atoms of the atomic ensemble by more than a dipole-dipole interaction length.
Mobile bound states of Rydberg excitations in a lattice
NASA Astrophysics Data System (ADS)
Letscher, Fabian; Petrosyan, David
2018-04-01
Spin-lattice models play a central role in the studies of quantum magnetism and nonequilibrium dynamics of spin excitations—-magnons. We show that a spin lattice with strong nearest-neighbor interactions and tunable long-range hopping of excitations can be realized by a regular array of laser-driven atoms, with an excited Rydberg state representing the spin-up state and a Rydberg-dressed ground state corresponding to the spin-down state. We find exotic interaction-bound states of magnons that propagate in the lattice via the combination of resonant two-site hopping and nonresonant second-order hopping processes. Arrays of trapped Rydberg-dressed atoms can thus serve as a flexible platform to simulate and study fundamental few-body dynamics in spin lattices.
Rapid hemostatic and mild polyurethane-urea foam wound dressing for promoting wound healing.
Liu, Xiangyu; Niu, Yuqing; Chen, Kevin C; Chen, Shiguo
2017-02-01
A novel rapid hemostatic and mild polyurethane-urea foam (PUUF) wound dressing was prepared by the particle leaching method and vacuum freeze-drying method using 4, 4-Methylenebis(cyclohexyl isocyanate), 4,4-diaminodicyclohexylmethane and poly (ethylene glycol) as raw materials. And X-ray diffraction (XRD), tensile test, differential scanning calorimetry (DSC) and thermogravimetry (TG) were used to its crystallinity, stress and strain behavior, and thermal properties, respectively. Platelet adhesion, fibrinogen adhesion and blood clotting were performed to evaluate its hemostatic effect. And H&E staining and Masson Trichrome staining were used to its wound healing efficacy. The results revealed the pore size of PUUF is 50-130μm, and its porosity is 71.01%. Porous PUUF exhibited good water uptake that was benefit to adsorb abundant wound exudates to build a regional moist environment beneficial for wound healing. The PUUF wound dressing exhibit better blood coagulation effect than commercial polyurethane dressing (CaduMedi). Though both PUUF and CaduMedi facilitated wound healing generating full re-epithelialization within 13days, PUUF was milder and lead to more slight inflammatory response than CaduMedi. In addition, PUUF wound dressing exhibited lower cytotoxicity than CaduMedi against NIH3T3 cells. Overall, porous PUUF represents a novel mild wound dressing with excellent water uptake, hemostatic effect and low toxicity, and it can promote wound healing and enhance re-epithelialization. Copyright © 2016 Elsevier B.V. All rights reserved.
Small, Charlotte; Stone, Robert; Pilsbury, Jane; Bowden, Michael; Bion, Julian
2015-08-05
The pain of a severe burn injury is often characterised by intense background pain, coupled with severe exacerbations associated with essential procedures such as dressing changes. The experience of pain is affected by patients' psychological state and can be enhanced by the anxiety, fear and distress caused by environmental and visual inputs. Virtual Reality (VR) distraction has been used with success in areas such as burns, paediatrics and oncology. The underlying principle of VR is that attention is diverted from the painful stimulus by the use of engaging, dynamic 3D visual content and associated auditory stimuli. Functional magnetic resonance imaging (fMRI) studies undertaken during VR distraction from experimental pain have demonstrated enhancement of the descending cortical pain-control system. The present study will evaluate the feasibility of introducing a novel VR system to the Burns Unit at the Queen Elizabeth Hospital Birmingham for dressing changes: virtual restorative environment therapy (VRET). The study will also explore the system's impact on pain during and after the dressing changes compared to conventional analgesia for ward-based burn dressing changes. A within-subject crossover design will be used to compare the following three conditions: 1. Interactive VRET plus conventional analgesics. 2. Passive VRET with conventional analgesics. 3. Conventional analgesics alone. Using the Monte Carlo method, and on the basis of previous local audit data, a sample size of 25 will detect a clinically significant 33 % reduction in worst pain scores experienced during dressing changes. The study accrual rate is currently slower than predicted by previous audits of admission data. A review of the screening log has found that recruitment has been limited by the nature of burn care, the ability of burn inpatients to provide informed consent and the ability of patients to use the VR equipment. Prior to the introduction of novel interactive technologies for patient use, the characteristics and capabilities of the target population needs to be evaluated, to ensure that the interface devices and simulations are usable. Current Controlled Trials ISRCTN23330756 . Date of Registration 25 February 2014.
Metcalf, Daniel G; Parsons, David; Bowler, Philip G
2017-02-01
The objective of this work was to evaluate the safety and effectiveness of a next-generation antimicrobial wound dressing (NGAD; AQUACEL ® Ag+ Extra™ dressing) designed to manage exudate, infection and biofilm. Clinicians were requested to evaluate the NGAD within their standard protocol of care for up to 4 weeks, or as long as deemed clinically appropriate, in challenging wounds that were considered to be impeded by suspected biofilm or infection. Baseline information and post-evaluation dressing safety and effectiveness data were recorded using standardised evaluation forms. This data included wound exudate levels, wound bed appearance including suspected biofilm, wound progression, skin health and dressing usage. A total of 112 wounds from 111 patients were included in the evaluations, with a median duration of 12 months, and biofilm was suspected in over half of all wounds (54%). After the introduction of the NGAD, exudate levels had shifted from predominantly high or moderate to low or moderate levels, while biofilm suspicion fell from 54% to 27% of wounds. Wound bed coverage by tissue type was generally shifted from sloughy or suspected biofilm towards predominantly granulation tissue after the inclusion of the NGAD. Stagnant (65%) and deteriorating wounds (27%) were shifted to improved (65%) or healed wounds (13%), while skin health was also reported to have improved in 63% of wounds. High levels of clinician satisfaction with the dressing effectiveness and change frequency were accompanied by a low number of dressing-related adverse events (n = 3; 2·7%) and other negative observations or comments. This clinical user evaluation supports the growing body of evidence that the anti-biofilm technology in the NGAD results in a safe and effective dressing for the management of a variety of challenging wound types. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Optimizing the Moisture Management Tightrope with Wound Bed Preparation 2015©.
Sibbald, R Gary; Elliott, James A; Ayello, Elizabeth A; Somayaji, Ranjani
2015-10-01
To provide an overview of moisture management and its importance in wound care. This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Summarize causes and treatments for moisture balance issues of chronic wounds.2. Recognize the properties of dressings used for treatment for moisture management of chronic wounds and antiseptic agent cytotoxicity.3. Explain study findings of the effectiveness of dressing choices for treatment of chronic wounds. To provide an overview of moisture management and its importance in wound care. The authors evaluate the impact of moisture management for optimal wound care and assess current wound management strategies relating to antisepsis and moist wound healing utilizing the wound bed preparation paradigm 2015 update. The discussion distinguishes the form and function of wound care dressing classes available for optimal moisture management. Moisture management for chronic wounds is best achieved with modern moist interactive dressings if the wound has the ability to heal.
Large thermopower from dressed quasiparticles in the layered cobaltates and rhodates
Chen, Su-Di; He, Yu; Zong, Alfred; ...
2017-08-15
The origin of the large thermopower in Na x CoO 2 is complicated by correlation phenomena. To disentangle the effects from multiple interactions, we use angle-resolved photoemission to study K x RhO 2, an isostructural analogy of Na xCoO 2 with large thermopower and weak electron correlation. In using the experimentally measured electronic structure, we demonstrate that the thermopower in K xRhO 2 can be quantitatively explained within the quasiparticle framework after including an electron-phonon mass enhancement effect. Extending the analysis to the cobaltate, we find the doubling in thermopower is well accounted for by additional band renormalization frommore » electron correlation. Thus, the large thermopower emerges from the itinerant quasiparticles dressed by hierarchical electron-phonon and electron-electron interactions.« less
Dykes, P J; Heggie, R
2003-07-01
The study compared the level of discomfort experienced by healthy volunteers on the removal of a range of adhesive wounds. This was an open, within subject comparative study of six adhesive dressings in 24 volunteers. The test site was the lower back. Allocation of test materials to the test sites was randomised. The peel force of removal was recorded after 24 hours of application using a device that removed the dressing at a constant speed and angle to the skin surface. The discomfort experienced at each removal was assessed by the subjects themselves using an electronic visual analogue scale. Overall, Mepilex Border was given a significantly lower discomfort score (p < or = 0.01) by the subjects than the other dressings. There were no clear differences between the five other products tested. Tielle and Allevyn Adhesive had significantly higher (p < or = 0.05) peel force than the other products. Mepilex Border caused less discomfort on removal than Duoderm Extra Thin, Biatain and Versiva, even though the peel force was similar. Tielle and Allevyn had higher peel force, but the levels of discomfort were not significantly higher for these products. It may be that the level of discomfort experienced by subjects on removal of an adhesive dressing is not entirely dependent on the peel force and that other aspects of the interaction of the skin surface and adhesive play a role.
Qu, Xue; Liu, Huan; Zhang, Chuchu; Lei, Yu; Lei, Miao; Xu, Miao; Jin, Dawei; Li, Peng; Yin, Meng; Payne, Gregory F; Liu, Changsheng
2018-06-01
Electrical signals can be imposed with exquisite spatiotemporal control and provide exciting opportunities to create structure and confer function. Here, we report the use of electrical signals to program the fabrication of a chloramine wound dressing with high antimicrobial activity. This method involves two electrofabrication steps: (i) a cathodic electrodeposition of an aminopolysaccharide chitosan triggered by a localized region of high pH; and (ii) an anodic chlorination of the deposited film in the presence of chloride. This electrofabrication process is completed within several minutes and the chlorinated chitosan can be peeled from the electrode to yield a free-standing film. The presence of active NCl species in this electrofabricated film was confirmed with chlorination occurring first on the amine groups and then on the amide groups when large anodic charges were used. Electrofabrication is quantitatively controllable as the cathodic input controls film growth during deposition and the anodic input controls film chlorination. In vitro studies demonstrate that the chlorinated chitosan film has antimicrobial activities that depend on the chlorination degree. In vivo studies with a MRSA infected wound healing model indicate that the chlorinated chitosan film inhibited bacterial growth, induced less inflammation, developed reorganized epithelial and dermis structures, and thus promoted wound healing compared to a bare wound or wound treated with unmodified chitosan. These results demonstrate the fabrication of advanced functional materials (i.e., antimicrobial wound dressings) using controllable electrical signals to both organize structure through non-covalent interactions (i.e., induce chitosan's reversible self-assembly) and to initiate function-conferring covalent modifications (i.e., generate chloramine bonds). Potentially, electrofabrication may provide a simple, low cost and sustainable alternative for materials fabrication. We believe this work is novel because this is the first report (to our knowledge) that electronic signals enable the fabrication of advanced antimicrobial dressings with controlled structure and biological performance. We believe this work is significant because electrofabrication enables rapid, controllable and sustainable materials construction with reduced adverse environmental impacts while generating high performance materials for healthcare applications. More specifically, we report an electrofbrication of antimicrobial film that can promote wound healing. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Giant plasmonic energy and momentum transfer on the nanoscale
NASA Astrophysics Data System (ADS)
Durach, Maxim
We have developed a general theory of the plasmonic enhancement of many-body phenomena resulting in a closed expression for the surface plasmon-dressed Coulomb interaction. It is shown that this interaction has a resonant nature. We have also demonstrated that renormalized interaction is a long-ranged interaction whose intensity is considerably increased compared to bare Coulomb interaction over the entire region near the plasmonic nanostructure. We illustrate this theory by re-deriving the mirror charge potential near a metal sphere as well as the quasistatic potential behind the so-called perfect lens at the surface plasmon (SP) frequency. The dressed interaction for an important example of a metal--dielectric nanoshell is also explicitly calculated and analyzed. The renormalization and plasmonic enhancement of the Coulomb interaction is a universal effect, which affects a wide range of many-body phenomena in the vicinity of metal nanostructures: chemical reactions, scattering between charge carriers, exciton formation, Auger recombination, carrier multiplication, etc. We have described the nanoplasmonic-enhanced Forster resonant energy transfer (FRET) between quantum dots near a metal nanoshell. It is shown that this process is very efficient near high-aspect-ratio nanoshells. We have also obtained a general expression for the force exerted by an electromagnetic field on an extended polarizable object. This expression is applicable to a wide range of situations important for nanotechnology. Most importantly, this result is of fundamental importance for processes involving interaction of nanoplasmonic fields with metal electrons. Using the obtained expression for the force, we have described a giant surface-plasmon-induced drag-effect rectification (SPIDER), which exists under conditions of the extreme nanoplasmonic confinement. Under realistic conditions in nanowires, this giant SPIDER generates rectified THz potential differences up to 10V and extremely strong electric fields up to 105--10 6 V/cm. It can serve as a powerful nanoscale source of THz radiation. The giant SPIDER opens up a new field of ultraintense THz nanooptics with wide potential applications in nanotechnology and nanoscience, including microelectronics, nanoplasmonics, and biomedicine. Additionally, the SPIDER is an ultrafast effect whose bandwidth for nanometric wires is 20 THz, which allows for detection of femtosecond pulses on the nanoscale. INDEX WORDS: Nanoplasmonics, Nanoplasmonic renormalization of Coulomb interaction, Surface-plasmon enhanced Forster energy transfer (FRET), Surface-plasmon-induced drag-effect rectification (SPIDER), Nanotechnology, Plasmonics on the nanoscale, Localized surface plasmons (LSPs), Surface plasmon polaritons (SPPs)
Patil, Pritam S; Fountas-Davis, Natalie; Huang, He; Michelle Evancho-Chapman, M; Fulton, Judith A; Shriver, Leah P; Leipzig, Nic D
2016-05-01
In this study, methacrylamide chitosan modified with perfluorocarbon chains (MACF) is used as the base material to construct hydrogel dressings for treating dermal wounds. MACF hydrogels saturated with oxygen (+O2) are examined for their ability to deliver and sustain oxygen, degrade in a biological environment, and promote wound healing in an animal model. The emerging technique of metabolomics is used to understand how MACF+O2 hydrogel dressings improve wound healing. Results indicate that MACF treatment facilitates oxygen transport rate that is two orders of magnitude greater than base MAC hydrogels. MACF hydrogel dressings are next tested in an in vivo splinted rat excisional wound healing model. Histological analysis reveals that MACF+O2 dressings improve re-epithelialization (p<0.0001) and synthesis of collagen over controls (p<0.01). Analysis of endogenous metabolites in the wounds using global metabolomics demonstrates that MACF+O2 dressings promotes a regenerative metabolic process directed toward hydroxyproline and collagen synthesis, with confirmation of metabolite levels within this pathway. The results of this study confirm that increased oxygen delivery through the application of MACF+O2 hydrogels enhances wound healing and metabolomics analyses provides a powerful tool to assess wound healing physiology. This work presents the first application of a novel class of oxygen delivering biomaterials (methacrylamide chitosan modified with perfluorocarbon chains (MACF)) as a hydrogel wound dressing. This manuscript also contains strong focus on the biochemical benefits of MACF dressings on underlying mechanisms vital to successful wound healing. In this vein, this manuscript presents the application of applied metabolomics (tandem mass spectroscopy) to uncover biomaterial interactions with wound healing mechanisms. We believe the approaches described in this manuscript will be of great interest to biomedical scientists and particularly to researchers studying wound healing, metabolomics, applied biomaterials and regenerative medicine. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Entangling atomic spins with a Rydberg-dressed spin-flip blockade
Jau, Y. -Y.; Hankin, A. M.; Keating, T.; ...
2015-10-05
Controlling the quantum entanglement between parts of a many-body system is key to unlocking the power of quantum technologies such as quantum computation, high-precision sensing, and the simulation of many-body physics. The spin degrees of freedom of ultracold neutral atoms in their ground electronic state provide a natural platform for such applications thanks to their long coherence times and the ability to control them with magneto-optical fields. However, the creation of strong coherent coupling between spins has been challenging. In this paper, we demonstrate a strong and tunable Rydberg-dressed interaction between spins of individually trapped caesium atoms with energy shiftsmore » of order 1 MHz in units of Planck’s constant. This interaction leads to a ground-state spin-flip blockade, whereby simultaneous hyperfine spin flips of two atoms are inhibited owing to their mutual interaction. Finally, we employ this spin-flip blockade to rapidly produce single-step Bell-state entanglement between two atoms with a fidelity ≥81(2)%.« less
Spontaneous dressed-state polarization in the strong driving regime of cavity QED.
Armen, Michael A; Miller, Anthony E; Mabuchi, Hideo
2009-10-23
We utilize high-bandwidth phase-quadrature homodyne measurement of the light transmitted through a Fabry-Perot cavity, driven strongly and on resonance, to detect excess phase noise induced by a single intracavity atom. We analyze the correlation properties and driving-strength dependence of the atom-induced phase noise to establish that it corresponds to the long-predicted phenomenon of spontaneous dressed-state polarization. Our experiment thus provides a demonstration of cavity quantum electrodynamics in the strong-driving regime in which one atom interacts strongly with a many-photon cavity field to produce novel quantum stochastic behavior.
The paradox of negative pressure wound therapy--in vitro studies.
Kairinos, Nicolas; Solomons, Michael; Hudson, Donald A
2010-01-01
Negative-pressure wound therapy (NPWT) has revolutionised wound care. Yet, it is still not understood how hypobaric tissue pressure accelerates wound healing. There is very little reported on the relevant physics of any substance subjected to suction in this manner. The common assumption is that applying suction to a substance is likely to result in a reduction of pressure in that substance. Although more than 250 research articles have been published on NPWT, there are little data verifying whether suction increases or decreases the pressure of the substance it is applied to. Clarifying this basic question of physics is the first step in understanding the mechanism of action of these dressings. In this study, pressure changes were recorded in soft plasticene and processed meat, using an intracranial tissue pressure microsensor. Circumferential, non-circumferential and cavity NPWT dressings were applied, and pressure changes within the underlying substance were recorded at different suction pressures. Pressures were also measured at 1cm, 2 cm and 3 cm from the NPWT placed in a cavity. In all three types of NPWT dressings, the underlying substance pressure was increased (hyperbaric) as suction pressure increased. Although there was a substantial pressure increase at 1cm, the rise in pressure at the 2-cm and 3-cm intervals was minimal. Substance pressure beneath all types of NPWT dressing is hyperbaric in inanimate substances. Higher suction pressures generate greater substance pressures; however, the increased pressure rapidly dissipates as the distance from the dressing is increased. The findings of this study on inanimate objects suggest that we may need to review our current perception of the physics underlying NPWT dressings. Further research of this type on living tissues is warranted. Copyright (c) 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Multilevel perspective on high-order harmonic generation in solids
NASA Astrophysics Data System (ADS)
Wu, Mengxi; Browne, Dana A.; Schafer, Kenneth J.; Gaarde, Mette B.
2016-12-01
We investigate high-order harmonic generation in a solid, modeled as a multilevel system dressed by a strong infrared laser field. We show that the cutoff energies and the relative strengths of the multiple plateaus that emerge in the harmonic spectrum can be understood both qualitatively and quantitatively by considering a combination of adiabatic and diabatic processes driven by the strong field. Such a model was recently used to interpret the multiple plateaus exhibited in harmonic spectra generated by solid argon and krypton [G. Ndabashimiye et al., Nature 534, 520 (2016), 10.1038/nature17660]. We also show that when the multilevel system originates from the Bloch state at the Γ point of the band structure, the laser-dressed states are equivalent to the Houston states [J. B. Krieger and G. J. Iafrate, Phys. Rev. B 33, 5494 (1986), 10.1103/PhysRevB.33.5494] and will therefore map out the band structure away from the Γ point as the laser field increases. This leads to a semiclassical three-step picture in momentum space that describes the high-order harmonic generation process in a solid.
Tong, Zongrui; Chen, Yu; Liu, Yang; Tong, Li; Chu, Jiamian; Xiao, Kecen; Zhou, Zhiyu; Dong, Wenbo; Chu, Xingwu
2017-01-01
Alginate (Alg) is a renewable polymer with excellent hemostatic properties and biocapability and is widely used for hemostatic wound dressing. However, the swelling properties of alginate-based wound dressings need to be promoted to meet the requirements of wider application. Poly(γ-glutamic acid) (PGA) is a natural polymer with high hydrophility. In the current study, novel Alg/PGA composite microparticles with double network structure were prepared by the emulsification/internal gelation method. It was found from the structure characterization that a double network structure was formed in the composite microparticles due to the ion chelation interaction between Ca2+ and the carboxylate groups of Alg and PGA and the electrostatic interaction between the secondary amine group of PGA and the carboxylate groups of Alg and PGA. The swelling behavior of the composite microparticles was significantly improved due to the high hydrophility of PGA. Influences of the preparing conditions on the swelling behavior of the composites were investigated. The porous microparticles could be formed while compositing of PGA. Thermal stability was studied by thermogravimetric analysis method. Moreover, in vitro cytocompatibility test of microparticles exhibited good biocompatibility with L929 cells. All results indicated that such Alg/PGA composite microparticles are a promising candidate in the field of wound dressing for hemostasis or rapid removal of exudates. PMID:28398222
Tong, Zongrui; Chen, Yu; Liu, Yang; Tong, Li; Chu, Jiamian; Xiao, Kecen; Zhou, Zhiyu; Dong, Wenbo; Chu, Xingwu
2017-04-11
Alginate (Alg) is a renewable polymer with excellent hemostatic properties and biocapability and is widely used for hemostatic wound dressing. However, the swelling properties of alginate-based wound dressings need to be promoted to meet the requirements of wider application. Poly( γ -glutamic acid) (PGA) is a natural polymer with high hydrophility. In the current study, novel Alg/PGA composite microparticles with double network structure were prepared by the emulsification/internal gelation method. It was found from the structure characterization that a double network structure was formed in the composite microparticles due to the ion chelation interaction between Ca 2+ and the carboxylate groups of Alg and PGA and the electrostatic interaction between the secondary amine group of PGA and the carboxylate groups of Alg and PGA. The swelling behavior of the composite microparticles was significantly improved due to the high hydrophility of PGA. Influences of the preparing conditions on the swelling behavior of the composites were investigated. The porous microparticles could be formed while compositing of PGA. Thermal stability was studied by thermogravimetric analysis method. Moreover, in vitro cytocompatibility test of microparticles exhibited good biocompatibility with L929 cells. All results indicated that such Alg/PGA composite microparticles are a promising candidate in the field of wound dressing for hemostasis or rapid removal of exudates.
Hickerson, W L; Kealey, G P; Smith, D J; Thomson, P D
1994-01-01
Three institutions enrolled 38 patients who required bilateral skin graft donor sites into a safety and efficacy study of a new synthetic donor site dressing. Bilateral donor sites were randomized to receive either a new, synthetic donor site dressing or an impregnated gauze dressing. Wounds were assessed by time to healing, pain, and patient preference. Synthetic dressing wounds were treated 7.9 days compared with 10.2 days for gauze dressing wounds (p < 0.001), and synthetic dressing wounds were more completely epithelialized. Visual analogue pain analysis revealed significantly less donor site pain with synthetic dressing (2.94) versus gauze dressing (4.64) (p < 0.001). Synthetic dressing had fewer treatment-related adverse experiences than gauze dressing (2 vs 7) and was judged by recipients to be superior to gauze dressing in comfort, pain relief, cosmetic appeal, ease of ambulation, and overall acceptance.
Jochim, Bethany; Siemering, R; Zohrabi, M; Voznyuk, O; Mahowald, J B; Schmitz, D G; Betsch, K J; Berry, Ben; Severt, T; Kling, Nora G; Burwitz, T G; Carnes, K D; Kling, M F; Ben-Itzhak, I; Wells, E; de Vivie-Riedle, R
2017-06-30
Much of our intuition about strong-field processes is built upon studies of diatomic molecules, which typically have electronic states that are relatively well separated in energy. In polyatomic molecules, however, the electronic states are closer together, leading to more complex interactions. A combined experimental and theoretical investigation of strong-field ionization followed by hydrogen elimination in the hydrocarbon series C 2 D 2 , C 2 D 4 and C 2 D 6 reveals that the photofragment angular distributions can only be understood when the field-dressed orbitals rather than the field-free orbitals are considered. Our measured angular distributions and intensity dependence show that these field-dressed orbitals can have strong Rydberg character for certain orientations of the molecule relative to the laser polarization and that they may contribute significantly to the hydrogen elimination dissociative ionization yield. These findings suggest that Rydberg contributions to field-dressed orbitals should be routinely considered when studying polyatomic molecules in intense laser fields.
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or non-sterile device intended to cover a wound, to absorb wound exudate, to control bleeding or fluid...
Silver-Zinc Redox-Coupled Electroceutical Wound Dressing Disrupts Bacterial Biofilm
Roy, Sashwati; Khanna, Savita; Hemann, Craig; Deng, Binbin; Das, Amitava; Zweier, Jay L.; Wozniak, Daniel; Sen, Chandan K.
2015-01-01
Pseudomonas aeruginosa biofilm is commonly associated with chronic wound infection. A FDA approved wireless electroceutical dressing (WED), which in the presence of conductive wound exudate gets activated to generate electric field (0.3–0.9V), was investigated for its anti-biofilm properties. Growth of pathogenic P. aeruginosa strain PAO1 in LB media was markedly arrested in the presence of the WED. Scanning electron microscopy demonstrated that WED markedly disrupted biofilm integrity in a setting where silver dressing was ineffective. Biofilm thickness and number of live bacterial cells were decreased in the presence of WED. Quorum sensing genes lasR and rhlR and activity of electric field sensitive enzyme, glycerol-3-phosphate dehydrogenase was also repressed by WED. This work provides first electron paramagnetic resonance spectroscopy evidence demonstrating that WED serves as a spontaneous source of reactive oxygen species. Redox-sensitive multidrug efflux systems mexAB and mexEF were repressed by WED. Taken together, these observations provide first evidence supporting the anti-biofilm properties of WED. PMID:25803639
Amna, Touseef; Hassan, M Shamshi; Yang, Jieun; Khil, Myung-Seob; Song, Ki-Duk; Oh, Jae-Don; Hwang, Inho
2014-01-01
Recently, substantial interest has been generated in using electrospun biomimetic nanofibers of hybrids, particularly organic/inorganic, to engineer different tissues. The present work, for the first time, introduced a unique natural and synthetic hybrid micronanofiber wound dressing, composed of virgin olive oil/copper oxide nanocrystals and polyurethane (PU), developed via facile electrospinning. The as-spun organic/inorganic hybrid micronanofibers were characterized by scanning electron microscopy (SEM), energy dispersive X-ray analysis, X-ray diffraction, electron probe microanalysis, and transmission electron microscopy. The interaction of cells with scaffold was studied by culturing NIH 3T3 fibroblasts on an as-spun hybrid micronanofibrous mat, and viability, proliferation, and growth were assessed. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay results and SEM observation showed that the hybrid micronanofibrous scaffold was noncytotoxic to fibroblast cell culture and was found to benefit cell attachment and proliferation. Hence our results suggest the potential utilization of as-spun micronanoscaffolds for tissue engineering. Copper oxide-olive oil/PU wound dressing may exert its positive beneficial effects at every stage during wound-healing progression, and these micronanofibers may serve diverse biomedical applications, such as tissue regeneration, damaged skin treatment, wound healing applications, etc. Conclusively, the fabricated olive oil-copper oxide/PU micronanofibers combine the benefits of virgin olive oil and copper oxide, and therefore hold great promise for biomedical applications in the near future.
Superfluidity of identical fermions in an optical lattice: Atoms and polar molecules
NASA Astrophysics Data System (ADS)
Fedorov, A. K.; Yudson, V. I.; Shlyapnikov, G. V.
2018-02-01
In this work we discuss the emergence of p-wave superfluids of identical fermions in 2D lattices. The optical lattice potential manifests itself in an interplay between an increase in the density of states on the Fermi surface and the modification of the fermion-fermion interaction (scattering) amplitude. The density of states is enhanced due to an increase of the effective mass of atoms. In deep lattices, for short-range interacting atoms the scattering amplitude is strongly reduced compared to free space due to a small overlap of wavefunctions of fermions sitting in the neighboring lattice sites, which suppresses the p-wave superfluidity. However, we show that for a moderate lattice depth there is still a possibility to create atomic p-wave superfluids with sizable transition temperatures. The situation is drastically different for fermionic polar molecules. Being dressed with a microwave field, they acquire a dipole-dipole attractive tail in the interaction potential. Then, due to a long-range character of the dipole-dipole interaction, the effect of the suppression of the scattering amplitude in 2D lattices is absent. This leads to the emergence of a stable topological px + ipy superfluid of identical microwave-dressed polar molecules.
NASA Astrophysics Data System (ADS)
Hargart, F.; Roy-Choudhury, K.; John, T.; Portalupi, S. L.; Schneider, C.; Höfling, S.; Kamp, M.; Hughes, S.; Michler, P.
2016-12-01
In this work we present an extensive experimental and theoretical investigation of different regimes of strong field light-matter interaction for cavity-driven quantum dot (QD) cavity systems. The electric field enhancement inside a high-Q micropillar cavity facilitates exceptionally strong interaction with few cavity photons, enabling the simultaneous investigation for a wide range of QD-laser detuning. In case of a resonant drive, the formation of dressed states and a Mollow triplet sideband splitting of up to 45 μeV is measured for a mean cavity photon number < {n}c> ≤slant 1. In the asymptotic limit of the linear AC Stark effect we systematically investigate the power and detuning dependence of more than 400 QDs. Some QD-cavity systems exhibit an unexpected anomalous Stark shift, which can be explained by an extended dressed 4-level QD model. We provide a detailed analysis of the QD-cavity systems properties enabling this novel effect. The experimental results are successfully reproduced using a polaron master equation approach for the QD-cavity system, which includes the driving laser field, exciton-cavity and exciton-phonon interactions.
Cheirmadurai, Kalirajan; Thanikaivelan, Palanisamy; Murali, Ragothaman
2016-02-10
Biomaterials based entirely on biological resources are ideal for tissue engineering applications. Here we report the preparation of hybrid collagen scaffolds comprising gulmohar seed polysaccharide (GSP) and cinnamon bark extract as cross-linking agent. (1)H NMR spectrum of GSP confirms the presence of galactose and mannose in the ratio of 1:1.54, which was further corroborated using FT-IR. The hybrid scaffolds show better enzyme and thermal stability in contrast to pure collagen scaffold probably due to weak interactions from GSP and covalent interaction through cinnamaldehyde. Gas permeability and scanning electron microscopic analysis show that the porosity of the hybrid scaffolds is slightly reduced with the increase in the concentration of GSP. The infrared and circular dichroic spectral studies show that the secondary structure of the collagen did not change after the interaction with GSP and cinnamaldehyde. The hybrid scaffolds stabilized with cinnamaldehyde show good antimicrobial activity against the common multi-drug resistant wound pathogens. These results suggest that the prepared hybrid scaffolds have great potential for antimicrobial wound dressing applications. Copyright © 2015 Elsevier Ltd. All rights reserved.
Preem, Liis; Mahmoudzadeh, Mohammad; Putrinš, Marta; Meos, Andres; Laidmäe, Ivo; Romann, Tavo; Aruväli, Jaan; Härmas, Riinu; Koivuniemi, Artturi; Bunker, Alex; Tenson, Tanel; Kogermann, Karin
2017-12-04
Antibacterial drug-loaded electrospun nano- and microfibrous dressings are of major interest as novel topical drug delivery systems in wound care. In this study, chloramphenicol (CAM)-loaded polycaprolactone (PCL) and PCL/poly(ethylene oxide) (PEO) fiber mats were electrospun and characterized in terms of morphology, drug distribution, physicochemical properties, drug release, swelling, cytotoxicity, and antibacterial activity. Computational modeling together with physicochemical analysis helped to elucidate possible interactions between the drug and carrier polymers. Strong interactions between PCL and CAM together with hydrophobicity of the system resulted in much slower drug release compared to the hydrophilic ternary system of PCL/PEO/CAM. Cytotoxicity studies confirmed safety of the fiber mats to murine NIH 3T3 cells. Disc diffusion assay demonstrated that both fast and slow release fiber mats reached effective concentrations and had similar antibacterial activity. A biofilm formation assay revealed that both blank matrices are good substrates for the bacterial attachment and formation of biofilm. Importantly, prolonged release of CAM from drug-loaded fibers helps to avoid biofilm formation onto the dressing and hence avoids the treatment failure.
Observation of Spin Polarons in a Tunable Fermi Liquid of Ultracold Atoms
NASA Astrophysics Data System (ADS)
Zwierlein, Martin
2009-05-01
We have observed spin polarons, dressed spin down impurities in a spin up Fermi sea of ultracold atoms via tomographic RF spectroscopy. Feshbach resonances allow to freely tune the interactions between the two spin states involved. A single spin down atom immersed in a Fermi sea of spin up atoms can do one of two things: For strong attraction, it can form a molecule with exactly one spin up partner, but for weaker interaction it will spread its attraction and surround itself with a collection of majority atoms. This spin down atom dressed with a spin up cloud constitutes the spin- or Fermi polaron. We have observed a striking spectroscopic signature of this quasi-particle for various interaction strengths, a narrow peak in the spin down spectrum that emerges above a broad background. The spectra allow us to directly measure the polaron energy and the quasi-particle residue Z. The polarons are found to be only weakly interacting with each other, and can thus be identified with the quasi-particles of Landau's Fermi liquid theory. At a critical interaction strength, we observe a transition from spin one-half polarons to spin zero molecules. At this point the Fermi liquid undergoes a phase transition into a superfluid Bose liquid.
Ge, Yanling; Palva, Airi; Nordström, Katrina
2017-01-01
Infected superficial wounds were traditionally controlled by topical antibiotics until the emergence of antibiotic-resistant bacteria. Silver (Ag) is a kernel for alternative antibacterial agents to fight this resistance quandary. The present study demonstrates a method for immobilizing small-sized (~5 nm) silver nanoparticles on silica matrix to form a nanosilver–silica (Ag–SiO2) composite and shows the prolonged antibacterial effects of the composite in vitro. The composite exhibited a rapid initial Ag release after 24 h and a slower leaching after 48 and 72 h and was effective against both methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli (E. coli). Ultraviolet (UV)-irradiation was superior to filter-sterilization in retaining the antibacterial effects of the composite, through the higher remaining Ag concentration. A gauze, impregnated with the Ag–SiO2 composite, showed higher antibacterial effects against MRSA and E. coli than a commercial Ag-containing dressing, indicating a potential for the management and infection control of superficial wounds. Transmission and scanning transmission electron microscope analyses of the composite-treated MRSA revealed an interaction of the released silver ions with the bacterial cytoplasmic constituents, causing ultimately the loss of bacterial membranes. The present results indicate that the Ag–SiO2 composite, with prolonged antibacterial effects, is a promising candidate for wound dressing applications. PMID:28878170
Improvement of Human Keratinocyte Migration by a Redox Active Bioelectric Dressing
Banerjee, Jaideep; Das Ghatak, Piya; Roy, Sashwati; Khanna, Savita; Sequin, Emily K.; Bellman, Karen; Dickinson, Bryan C.; Suri, Prerna; Subramaniam, Vish V.; Chang, Christopher J.; Sen, Chandan K.
2014-01-01
Exogenous application of an electric field can direct cell migration and improve wound healing; however clinical application of the therapy remains elusive due to lack of a suitable device and hence, limitations in understanding the molecular mechanisms. Here we report on a novel FDA approved redox-active Ag/Zn bioelectric dressing (BED) which generates electric fields. To develop a mechanistic understanding of how the BED may potentially influence wound re-epithelialization, we direct emphasis on understanding the influence of BED on human keratinocyte cell migration. Mapping of the electrical field generated by BED led to the observation that BED increases keratinocyte migration by three mechanisms: (i) generating hydrogen peroxide, known to be a potent driver of redox signaling, (ii) phosphorylation of redox-sensitive IGF1R directly implicated in cell migration, and (iii) reduction of protein thiols and increase in integrinαv expression, both of which are known to be drivers of cell migration. BED also increased keratinocyte mitochondrial membrane potential consistent with its ability to fuel an energy demanding migration process. Electric fields generated by a Ag/Zn BED can cross-talk with keratinocytes via redox-dependent processes improving keratinocyte migration, a critical event in wound re-epithelialization. PMID:24595050
Multi-modal distraction. Using technology to combat pain in young children with burn injuries.
Miller, Kate; Rodger, Sylvia; Bucolo, Sam; Greer, Ristan; Kimble, Roy M
2010-08-01
The use of non-pharmacological pain management remains adhoc within acute paediatric burns pain management protocols despite ongoing acknowledgement of its role. Advancements in adult based pain services including the integration of virtual reality has been adapted to meet the needs of children in pain, as exemplified by the development of multi-modal distraction (MMD). This easy to use, hand held interactive device uses customized programs designed to inform the child about the procedure he/she is about to experience and to distract the child during dressing changes. (1) To investigate if either MMD procedural preparation (MMD-PP) or distraction (MMD-D) has a greater impact on child pain reduction compared to standard distraction (SD) or hand held video game distraction (VG), (2) to understand the impact of MMD-PP and MMD-D on clinic efficiency by measuring length of treatment across groups, and lastly, (3) to assess the efficacy of distraction techniques over three dressing change procedures. A prospective randomised control trial was completed in a paediatric tertiary hospital Burns Outpatient Clinic. Eighty participants were recruited and studied over their first three dressing changes. Pain was assessed using validated child report, caregiver report, nursing observation and physiological measures. MMD-D and MMD-PP were both shown to significantly relieve reported pain (p
Phaechamud, Thawatchai; Yodkhum, Kotchamon; Charoenteeraboon, Juree; Tabata, Yasuhiko
2015-05-01
There are many factors that delay healing in chronic wounds including lowering level of growth factors and increasing exudate level comprising high amount of tissue destructive enzymes. Asiaticoside possesses interesting wound healing and angiogenic activities that are employed to stimulate tissue regeneration in wound healing application. This study attempted to develop chitosan-aluminum monostearate (Alst) composite sponge containing asiaticoside for use as an absorbent medical dressing in chronic wound. N-methyl-2-pyrrolidone (NMP) was used to enhance homogeneity of asiaticoside in the polymer composite matrix. The sponge dressings were prepared by lyophilization and dehydrothermal treatment (DHT). Functional group interaction, crystallinity, and morphology of the prepared sponges were investigated using FT-IR, PXRD, and SEM, respectively. Physicochemical properties, porosity, hydrophilic/hydrophobic properties and mechanical property, were evaluated. Wound dressing properties, water vapor transmission rate (WVTR), fluid absorbency, oxygen permeation (OP), and bio-adhesive property, were investigated. In vitro asiaticoside release study was conducted using immersion method. Cytotoxicity was studied in normal human dermal fibroblast (NHDF) and normal human epidermal keratinocyte (NHEK). Angiogenic activity of asiaticoside was evaluated using chick-chorioallantoic membrane (CAM) assay. FT-IR and PXRD results revealed the amidation after DHT to enhance the crystallinity of the prepared sponges. The prepared sponges had high porosity comprising high Alst-loaded amount that exhibited more compact structure. Alst enhanced hydrophobicity therefore it reduced the fluid absorption and WVTR together with bio-adhesion of the prepared sponge dressings. Porosity of all sponges was more than 85% therefore resulting in their high OP. Enhancing hydrophobicity of the material by Alst and more homogeneity caused by NMP eventually retarded the asiaticoside release for 7 days. The sponge extractions were non-toxic to the cells moreover they promoted NHDF and NHEK cell proliferation. Asiaticoside and asiaticoside-contained dressings exhibited dose-dependent angiogenic activity in CAM model. Copyright © 2015 Elsevier B.V. All rights reserved.
Comparison of two silver dressings for wound management in pediatric burns.
Jester, Ingo; Bohn, Ingo; Hannmann, Thorsten; Waag, Karl-Ludwig; Loff, Steffan
2008-11-01
Purpose. Silver wound dressings are widely used in the treatment of burns. Dressings differ in material characteristics, various antimicrobial activities, and ease of use. The purpose of this study was to evaluate both dressing performance and amount of pain during the dressing changes of 2 silver dressings Urgotul SSD® (Laboratoires Urgo, Chenove, France), and Contreet Ag® (Coloplast, Minneapolis, MN) in children. A retrospective cohort study was performed with 2 groups of 20 burns treated with Urgotul SSD and Contreet Ag until the wounds were healed or grafted. Seventy dressing changes in the Contreet Ag group and 67 dressing changes in the Urgotul group were evaluated. Every dressing change was assessed regarding the dressing performance (exudate, adherence, bleeding, and dressing application/removal), and pain. Pain was "absent or slight" in 61 (92%) dressing changes with Urgotul SSD, and in 60 (85%) of the dressing changes with Contreet Ag. Dressing application in the Urgotul group was more often "very easy" (n = 33; 49%) or "easy" (n = 32; 48%) than in the Contreet Ag group, "very easy" (n = 25; 35%), and "easy" (n = 42; 60%). Contreet Ag had a greater ability to absorb exudate ("very good" n = 60; 85%, and "good" n = 11; 15%) than Urgotul SSD ("very good" n = 34; 51%, and "good" n = 13; 19%). Urgotul SSD and Contreet Ag are comparable regarding pain during dressing change. The dressings differ in their ability to absorb exudate and ease of application. Both dressings provided nearly painless wound management, and therefore were highly accepted by the nurses and especially the children being treated.
Choosing a Wound Dressing Based on Common Wound Characteristics
Dabiri, Ganary; Damstetter, Elizabeth; Phillips, Tania
2016-01-01
Significance: Chronic wounds are a major healthcare burden.The practitioner should have an appropriate understanding of both the etiology of the wound as well as the optimal type of dressings to use. Fundamental wound characteristics may be used to guide the practitioner's choice of dressings. The identification of optimal dressings to use for a particular wound type is an important element in facilitating wound healing. Recent Advances: Researchers have sought to design wound dressings that aim to optimize each stage in the healing process. In addition, dressings have been designed to target and kill infection-causing bacteria, with the incorporation of antimicrobial agents. Critical Issues: Chronic wounds are frequently dynamic in presentation, and the numerous wound dressings available make dressing selection challenging for the practitioner. Choosing the correct dressing decreases time to healing, provides cost-effective care, and improves patient quality of life. Future Directions: Research into the mechanisms of wound healing has enhanced our ability to heal chronic wounds at a faster rate through the use of moisture-retentive dressings. Newer dressings are incorporating the use of nanotechnology by incorporating miniature electrical sensors into the dressing. These dressings are engineered to detect changes in a wound environment and alert the patient or practitioner by altering the color of the dressing or sending a message to a smartphone. Additional investigations are underway that incorporate biologic material such as stem cells into dressings. PMID:26858913
Hudson, W. R.; Roberts, T. A.; Whelehan, O. P.
1987-01-01
The bacteriological status of beef carcasses was monitored at a commercial abattoir before and after two stages of modernization to the beef slaughterline which included changing from cradle dressing to dressing on an overhead rail, and the introduction of hot water spray cleaning of carcasses. Although small significant (P less than 0.05) differences in bacterial count occurred among carcass sites within modernization stages, significant visit within stage variation and stage X site interactions prevented any significant change in overall count being observed among stages and carcass sites. Principal components analysis revealed small changes in the distribution of bacterial numbers on the sites sampled. PMID:3556439
Semiconductor quantum well irradiated by a two-mode electromagnetic field as a terahertz emitter
NASA Astrophysics Data System (ADS)
Mandal, S.; Liew, T. C. H.; Kibis, O. V.
2018-04-01
We study theoretically the nonlinear optical properties of a semiconductor quantum well (QW) irradiated by a two-mode electromagnetic wave consisting of a strong resonant dressing field and a weak off-resonant driving field. In the considered strongly coupled electron-field system, the dressing field opens dynamic Stark gaps in the electron energy spectrum of the QW, whereas the driving field induces electron oscillations in the QW plane. Since the gapped electron spectrum restricts the amplitude of the oscillations, the emission of a frequency comb from the QW appears. Therefore, the doubly driven QW operates as a nonlinear optical element which can be used, particularly, for optically controlled generation of terahertz radiation.
Two Japanese variants of the absolute transvestite film.
Stringer, J
2000-01-01
This essay compares two Japanese transvestite films from different generations-Black Lizard of 1968 and Summer Vacation 1999 of 1988. While Western transvestite conventions are usually exploited only to climactically reinforce heterosexual coupling, what binds these two films is their divergent tradition of what I call "permanent transvestism." That is, the films employ a cross-dressing which occurs extra-diegetically, is unnecessary to the plot, and which an audience may or may not be aware of depending on their geo-historical position. However, it is this non-Western tradition of cross-dressing that nevertheless imparts an aestheticization of sexual desire beyond fixed categories of "gay," "lesbian," or even our conventional ideas of transsexualism.
Evaluation of a non-adherent, povidone-iodine dressing in a case series of chronic wounds.
Campbell, N; Campbell, D
2013-08-01
Here we report a product evaluation for a non-adherent, povidone-iodine (PVP-I) dressing, determining the clinical need for the product, performing a literature review, clinical evaluation and cost-analysis, and developing a recommendation. This evaluation included 20 patients who experienced dressing pain with the previous antimicrobial dressing. Two patients discontinued the evaluation and four ulcers were non-healing; the remaining wounds closed with the PVP-I dressing. Patients indicated a preference for the PVP-I dressing, primarily due to lack of dressing pain. The PVP-I dressing was also the most cost-efficient.
Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick
2012-08-01
It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Hormbrey, E; Pandya, A; Giele, H
2003-07-01
Painful split-skin-graft donor sites remain a common problem for patients. We undertook a prospective randomised trial to examine the comparative comfort and ease of care of two different donor-site dressings. One dressing is the alginate Kaltostat, the standard plastic-surgical dressing in the UK and abroad, and the other is the adhesive retention tape Mefix, a novel use of a readily available dressing. We randomised 50 patients requiring split-skin grafts to receive either alginate (Kaltostat) or retention (Mefix) donor-site dressings. Dressings were assessed by interview and questionnaire at 24, 72 h and 2 weeks, and by wound review at 2 weeks. Retention dressings were found to be more comfortable, required less nursing intervention and allowed patients easier mobility with a greater range of daily activities, especially washing, without compromising wound healing. We recommend adhesive retention dressings as cost-effective comfortable dressings, which readily conform to any donor site.
Vlassakidis, Alexander; Niepel, Mediha; Hoedke, Daniela; Schulze, Julia; Neumann, Konrad; Moter, Annette; Noetzel, Jörn
2017-01-01
The objective was to compare the antibacterial effects of adjunctive disinfection using diode laser and gaseous ozone compared to the medical dressings calcium hydroxide (Ca(OH)2) and chlorhexidine gel (CHX-Gel) on Enterococcus faecalis biofilms in human root canals ex vivo. Root canals of 180 human extracted teeth were infected by E. faecalis and divided into 3 main groups (G): G1, control; G2, instrumentation and irrigation using 0.9% NaCl; G3, instrumentation and irrigation using 1% NaOCl. In each main group, the following treatments were applied: gaseous ozone, diode laser, and medical dressings of Ca(OH)2 or CHX-Gel for 7 days (n = 15). Reduction of colony forming units (CFUs) inside the root canal of planktons and frequencies of adherent bacteria after treatment were calculated. Bacterial reduction was significantly affected by the irrigation protocol (p < 0.0005) and the disinfection method (p < 0.0005), and a significant interaction between both factors could be observed (p < 0.0005; ANOVA). In G3 (instrumentation using 1% NaOCl), no significant effect of disinfection methods could be demonstrated on planktonic bacteria (p = 0.062; ANOVA) and frequencies of adherent bacteria (p > 0.05; chi-square test). Instrumentation and irrigation using NaOCl combined with ozone or laser application resulted in comparable bacterial reduction on E. faecalis to the application of medical dressings. PMID:28567421
Real-time monitoring of moisture levels in wound dressings in vitro: an experimental study.
McColl, David; Cartlidge, Brian; Connolly, Patricia
2007-10-01
Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time. A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate flow. Eight monitoring points, situated beneath the test dressing, allow the moisture profile across the complete dressing to be measured both during and after fluid injection. The system has been used to evaluate the performance of four foam dressings, a composite hydrofibre dressing and a film dressing. Stark contrasts in the performance of the wound contact layer were found between the different wound dressing types. The composite hydrofibre dressing retained moisture at the wound interface throughout the experiments while areas of the foam dressing quickly became dry, even during constant injection of fluid. The abundance of sensors allowed a moisture map of the surface of the wound dressing to be constructed, illustrating that the moisture profile was not uniform across several of the dressings tested during absorption and evaporation of liquid. These results raise questions as to how the dressings behave on a wound in vivo and indicate the need for a similar clinical monitoring system for tracking wound moisture levels.
Symmetry preserving truncations of the gap and Bethe-Salpeter equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binosi, Daniele; Chang, Lei; Papavassiliou, Joannis
2016-05-01
Ward-Green-Takahashi (WGT) identities play a crucial role in hadron physics, e.g. imposing stringent relationships between the kernels of the one-and two-body problems, which must be preserved in any veracious treatment of mesons as bound states. In this connection, one may view the dressed gluon-quark vertex, Gamma(alpha)(mu), as fundamental. We use a novel representation of Gamma(alpha)(mu), in terms of the gluon-quark scattering matrix, to develop a method capable of elucidating the unique quark-antiquark Bethe-Salpeter kernel, K, that is symmetry consistent with a given quark gap equation. A strength of the scheme is its ability to expose and capitalize on graphic symmetriesmore » within the kernels. This is displayed in an analysis that reveals the origin of H-diagrams in K, which are two-particle-irreducible contributions, generated as two-loop diagrams involving the three-gluon vertex, that cannot be absorbed as a dressing of Gamma(alpha)(mu) in a Bethe-Salpeter kernel nor expressed as a member of the class of crossed-box diagrams. Thus, there are no general circumstances under which the WGT identities essential for a valid description of mesons can be preserved by a Bethe-Salpeter kernel obtained simply by dressing both gluon-quark vertices in a ladderlike truncation; and, moreover, adding any number of similarly dressed crossed-box diagrams cannot improve the situation.« less
Protein matrices for wound dressings =
NASA Astrophysics Data System (ADS)
Vasconcelos, Andreia Joana Costa
Fibrous proteins such as silk fibroin (SF), keratin (K) and elastin (EL) are able to mimic the extracellular matrix (ECM) that allows their recognition under physiological conditions. The impressive mechanical properties, the environmental stability, in combination with their biocompatibility and control of morphology, provide an important basis to use these proteins in biomedical applications like protein-based wound dressings. Along time the concept of wound dressings has changed from the traditional dressings such as honey or natural fibres, used just to protect the wound from external factors, to the interactive dressings of the present. Wounds can be classified in acute that heal in the expected time frame, and chronic, which fail to heal because the orderly sequence of events is disrupted at one or more stages of the healing process. Moreover, chronic wound exudates contain high levels of tissue destructive proteolytic enzymes such as human neutrophil elastase (HNE) that need to be controlled for a proper healing. The aim of this work is to exploit the self-assemble properties of silk fibroin, keratin and elastin for the development of new protein materials to be used as wound dressings: i) evaluation of the blending effect on the physical and chemical properties of the materials; ii) development of materials with different morphologies; iii) assessment of the cytocompatibility of the protein matrices; iv) ultimately, study the ability of the developed protein matrices as wound dressings through the use of human chronic wound exudate; v) use of innovative short peptide sequences that allow to target the control of high levels of HNE found on chronic wounds. Chapter III reports the preparation of silk fibroin/keratin (SF/K) blend films by solvent casting evaporation. Two solvent systems, aqueous and acidic, were used for the preparation of films from fibroin and keratin extracted from the respective silk and wool fibres. The effect of solvent system used was studied by evaluating the physical-chemical properties of the resulting films. It was shown that SF and K are able to establish intermolecular interactions when mixed and, that the mechanical properties and the biological degradation can be tuned by the blend composition. In Chapter IV, SF/K films were further used to serve as a platform for the release of HNE inhibitors peptides. Bowman-Birk inhibitor (BBI) based peptide was incorporated onto the SF/K films that were consequently incubated with porcine pancreatic elastase (PPE) as a model for HNE, to monitor the decrease in activity. The results indicated that swelling properties, degradation and release rates are dependent on the amount of keratin present in the blend. Furthermore, no cytotoxicity was observed in the presence of mouse fibroblasts, which makes these SF/K films suitable candidates for interactive wound dressings with a specific goal - controlling high levels of HNE. The next step of the work, Chapter V, reports for the first time blends of silk fibroin with elastin (SF/EL) for the production of scaffolds. These were prepared by lyophilization technique and crosslinked with a natural and low toxic agent, genipin. The crosslink allows the control of the scaffolds morphology, such as pore size and porosity, which in turns, modulates the ex vivo degradation rates, by a human chronic wound exudate, and the release rates of model compounds. In addition, no cytotoxicity was observed for SF/EL samples, with and without genipin, by human skin fibroblasts. Thus, the high porosity observed for SF/EL scaffolds, allowing the growth and cellular attachment, together with their biocompatibility provide fitting characteristics for wound dressings. Chapter VI, describes the design of two elastase inhibitors peptides based on the reactive site-loop of the BBI protein in order to control the high levels HNE. To a known peptide sequence, modifications were made at both N- and C-terminal. Inhibition kinetics analysis indicated that these peptides are competitive inhibitors for HNE and PPE and, that the inhibitory potency can be regulated by the introduced modifications. Additionally, these peptides showed no toxicity with human skin fibroblasts and, were also effective in reducing the HNE activity found in a human chronic wound exudate, which allow them to be applied to those wounds. The motivation for this thesis was to combine the excellent properties of silk fibroin with other proteins. Blending allows modulating the physical-chemical properties of the resulting materials such as mechanical strength, swelling, morphology, degradation and release rates. Silk fibroin is widely characterized in the literature for the production of biomaterials, but this work is the first that successfully evaluates the blends silk fibroin/keratin (SF/K) and silk fibroin/elastin (SF/EL) for their application as wound dressings.
Labbie, Michele; Willing, Benjamin
2017-01-01
Background Polymicrobial communities colonize all wounds, and biofilms are hypothesized to be a key link to the chronic state and stalled healing. Molecular methods offer greater insight when studying microbial ecology in chronic wounds, as only a small fraction of wound bacteria are cultured by currently available methods and studies have shown little agreement between culture and molecular based approaches. Some interventions, like dressings with oxidized silver, are reported to help the stalled wounds move to a normal healing trajectory but the underlying mechanisms are difficult to measure. One hypothesis is that the use of topical antimicrobial dressings targets the wound microbiome and reduces bioburden. Objectives Our objective was to determine if culture-independent molecular methods could be used to identify the microbial composition in chronic wounds, and measure the microbiome over time when a topical antimicrobial dressing is used to reduce bioburden. Methods Patients with chronic wounds defined as >6 weeks in duration and not taking systemic antibiotics were recruited to participate. A wound contact layer containing silver oxynitrate was applied immediately after routine sharp debridement material was collected and swabs of the wound bed taken. Next-generation sequencing of the bacterial 16S rRNA gene in each specimen was used to measure the microbiome. Results Distinct bacterial communities were observed between swab and debridement samples, highlighting spatial differences and the importance of sampling consistency. The microbial communities appeared to be similar between different diabetes statuses, but different among the three wound categories included. Conclusions Culture-independent methods can be applied to measure the microbiome of chronic wounds even when a topical antimicrobial dressing is applied to the wound. PMID:29155834
ERIC Educational Resources Information Center
Birel, Firat Kiyas
2016-01-01
Problem Statement: Dressing for school has been intensely disputed and has led to periodic changes in dress codes since the foundation of the Turkish republic. Practitioners have tried to put some new practices related to school dress codes into practice for redressing former dress code issues involving mandatory dress standards for both students…
Australasian survey of split skin graft donor site dressings.
Lyall, P W; Sinclair, S W
2000-02-01
There is an ever increasing array of products available for wound dressings. The aim of the present study was to establish which dressings should be used as standard controls for future studies; what factors are regarded as most important in assessing a dressing; what the level of satisfaction is with the available products; what the strengths and weaknesses of the commonly used dressings are; and what dressings would be preferred if cost were no issue. A postal survey was sent to every plastic and reconstructive surgeon registered in Australasia (n = 217). A total of 53% responded. The most commonly used dressing type overall is the calcium alginates, despite the fact that they were not the highest performing dressings. This is also the most commonly used in Australia. In contrast scarlet red is still used most commonly in New Zealand. The level of satisfaction with the most commonly used dressing varied very little. The factor regarded most important was patient comfort level. A profile of the commonly used dressing was constructed. Calcium alginates and or scarlet red should be used as the control for new product comparisons. Most of the respondents were satisfied with their preferred dressing and were not interested in trying alternative dressings.
Edwards, Melannie; Rickard, Claire M; Rapchuk, Ivan; Corley, Amanda; Marsh, Nicole; Spooner, Amy J; Mihala, Gabor; Fraser, John F
2014-09-01
To improve arterial catheter (AC) securement and reduce AC failure; to assess feasibility of a large randomised controlled trial. A four-arm, parallel, randomised, controlled, non-blinded pilot trial with 195 intensive care patients taking part, in a tertiary referral hospital in Brisbane, Australia from May to November 2012. Standard polyurethane (SPU) dressing (controls); bordered polyurethane (BPU) + SPU dressing; tissue adhesive (TA) + SPU dressing; and sutureless securement device (SSD) + SPU dressing (no sutures used). AC failure, ie, complete dislodgement, occlusion (monitor failure, inability to infuse or fluid leaking), pain or infection (local or blood). Median AC dwell time was 26.2 hours and was comparable between groups. AC failure occurred in 26/195 patients (13%). AC failure was significantly worse with SPU dressings (10/47 [21%]) than with BPU + SPU dressings (2/ 43 [5%]; P = 0.03), but not significantly different to TA + SPU (6/56 [11%]; P = 0.18) or SSD + SPU (8/49 [16%]; P = 0.61). The dressing applied at AC insertion lasted until AC removal in 68% of controls; 56% of BPU + SPU dressings; 73% of TA + SPU dressings; and 80% of SSD + SPU dressings (all P > 0.05). There were no infections or serious adverse events. Patient and staff satisfaction with all products was high. Median costs (labour and materials) for securement per patient were significantly higher in all groups compared with the control group (SPU, $3.48 [IQR, $3.48-$9.79]; BPU + SPU, $5.07 [IQR, $5.07-$12.99]; SSD + SPU, $10.90 [IQR, $10.90-$10.90]; TA + SPU, $17.70 [IQR, $17.70-$38.36]; all P < 0.01). AC failure occurred significantly less often with BPU + SPU dressings than with SPU dressings. TA + SPU and SSD + SPU dressings should be further investigated and compared with BPU + SPU dressings as controls. The novel approach of TA + SPU dressings appeared safe and feasible.
Dressing remedies: a concept for improving access to and use of dressings in nursing homes.
Clarkson, A
2007-01-01
Delays in accessing dressings prescribed by general practitioners can result in the inappropriate use of dressings on more than one resident in nursing homes. The dressing remedies concept was developed to overcomes this problem.
Matiasek, J; Domig, K J; Djedovic, G; Babeluk, R; Assadian, O
2017-05-02
The aim of this study was to investigate the bacterial bioburden in experimental in vitro wounds during the application of conventional negative pressure wound therapy (NPWT), with and without antimicrobial dressings (polyhexanide, silver), against NPWT instillation of octenidine. Experimental wounds produced in an in vitro porcine wound model were homogenously contaminated with bacterial suspension and treated with NPWT and different options. Group A: non-antimicrobial polyurethane foam dressing; group B: antimicrobial polyurethane foam dressing containing silver; group C: antimicrobial gauze dressing containing polyhexanide; group D: non-antimicrobial polyurethane foam dressing intermittently irrigated with octenidine; group E: negative control (non-antimicrobial polyurethane foam dressing without NPWT). Standard biopsies were harvested after 24 and 28 hours. This study demonstrated that the use of NPWT with intermitted instillation of octenidine (group D) or application of silver-based polyurethane foam dressings (group B) is significantly superior against Staphylococcus aureus colonisation in experimental wounds compared with non-antimicrobial polyurethane foam dressing (group A) after 48 hours. Surprisingly, the polyhexanide-based dressing (group C) used in this model showed no statistical significant effect compared with the control group (group E) after 24 or 48 hours of treatment. Both intermitted instillation of octenidine and silver-based dressings in standard NPWT were significantly superior compared with non-antimicrobial polyurethane foam dressings or PHMB coated gauze dressing after 48 hours.
Exit-Site Dressing and Infection in Peritoneal Dialysis: A Randomized Controlled Pilot Trial.
Mushahar, Lily; Mei, Lim Wei; Yusuf, Wan Shaariah; Sivathasan, Sudhaharan; Kamaruddin, Norilah; Idzham, Nor Juliana Mohd
2016-01-01
♦ Peritoneal dialysis (PD)-related infection is a common cause of catheter loss and the main reason for PD drop-out. Exit-site infection (ESI) is a pathway to developing tunnel infection and peritonitis, hence rigorous exit-site care has always been emphasized in PD therapy. The aim of this study was to evaluate the effect of exit-site dressing vs non-dressing on the rate of PD-related infection. ♦ A prospective randomized controlled study was conducted in prevalent PD patients at the Hospital Tuanku Jaafar Seremban, Negeri Sembilan, Malaysia, from April 2011 until April 2013. All patients were required to perform daily washing of the exit site with antibacterial soap during a shower. In the dressing group (n = 54), patients were required to clean their exit site using povidone-iodine after drying, followed by topical mupirocin antibiotic application to the exit site. The exit site was then covered with a sterile gauze dressing and the catheter immobilized with tape. In the non-dressing group (n = 54), patients were not required to do any further dressing after drying. They were only required to apply mupirocin cream to the exit site and then left the exit site uncovered. The catheter was immobilized with tape. The primary outcome was ESI. The secondary outcomes were evidence of tunnel infection or peritonitis. ♦ A total of 97 patients completed the study. There were a total of 12 ESI episodes: 4 episodes in 4 patients in the dressing group vs 8 episodes in 4 patients in the non-dressing group. This corresponds to 1 episode per 241.3 patient-months vs 1 episode per 111.1 patient-months in the dressing and non-dressing groups respectively. Median time to first ESI episode was shorter in the non-dressing than in the dressing group, but not significant (p = 0.25). The incidence of gram-positive ESI in both groups was similar. There were no gram-negative ESI in the non-dressing group compared with 2 in the dressing group. The peritonitis rate was 1 per 37.1 patient-month in the dressing group and 1 per 44.4 patient-months in the non-dressing group. Median time to first peritonitis episode was significantly shorter in the dressing group compared to non-dressing (p = 0.03). There was no impact of dressing disruptions in the occurrence of major PD catheter-related infection. ♦ Use of a non-dressing technique with only prophylactic topical mupirocin cream application is effective in preventing PD-related infection. The non-dressing technique is more cost-effective and convenient for PD patients, with fewer disposables. Copyright © 2016 International Society for Peritoneal Dialysis.
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate.
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L; Carty, Neal; Johnson, Peter
2015-01-01
Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes.
Kanokpanont, Sorada; Damrongsakkul, Siriporn; Ratanavaraporn, Juthamas; Aramwit, Pornanong
2013-04-01
Silk fibroin (SF) has been widely used as a wound dressing material due to its suitable physical and biological characteristics. In this study, a non-adhesive wound dressing which applies to cover the wound surface as an absorbent pad that would absorb wound fluid while accelerate wound healing was developed. The modification of SF fabrics by wax coating was purposed to prepare the non-adhesive wound dressing that is required in order to minimize pain and risk of repeated injury. SF woven fabrics were coated with different types of waxes including shellac wax, beeswax, or carnauba wax. Physical and mechanical properties of the wax-coated SF fabrics were characterized. It was clearly observed that all waxes could be successfully coated on the SF fabrics, possibly due to the hydrophobic interactions between hydrophobic domains of SF and waxes. The wax coating improved tensile modulus and percentage of elongation of the SF fabrics due to the denser structure and the thicker fibers coated. The in vitro degradation study demonstrated that all wax-coated SF fabrics remained up to 90% of their original weights after 7 weeks of incubation in lysozyme solution under physiological conditions. The wax coating did not affect the degradation behavior of the SF fabrics. A peel test of the wax-coated SF fabrics was carried out in the partial- and full-thickness wounds of porcine skin in comparison to that of the commercial wound dressing. Any wax-coated SF fabrics were less adhesive than the control, as confirmed by less number of cells attached and less adhesive force. This might be that the wax-coated SF fabrics showed the hydrophobic property, allowing the loosely adherence to the hydrophilic wound surface. In addition, the in vivo biocompatibility test of the wax-coated SF fabrics was performed in Sprague-Dawley rats with subcutaneous model. The irritation scores indicated that the carnauba wax-coated SF fabric was not irritant while the shellac wax or beeswax-coated SF fabrics were slightly irritant, comparing with the commercial wound dressing. Therefore, SF fabrics coated with waxes, particularly carnauba wax, would be promising choices of non-adhesive wound dressing. Copyright © 2013 Elsevier B.V. All rights reserved.
Closed dressings after laser skin resurfacing.
Newman, J P; Koch, R J; Goode, R L
1998-07-01
To evaluate the safety, efficacy, and patient acceptance of closed dressings after full facial resurfacing with the carbon dioxide laser. Prospective cohort of men and women undergoing full facial carbon dioxide laser resurfacing. Ambulatory surgical center at a university hospital. Forty consecutive patients randomized to 1 of 4 dressing groups. All patients underwent full facial resurfacing with a carbon dioxide laser system. One of 5 closed dressings (single- or 3-layer composite foam, plastic mesh, hydrogel, or polymer film) was placed immediately after the procedure. Closed dressings were changed on postoperative day 2 and removed on postoperative day 4. Objective postoperative criteria of erythema, scarring, reepithelialization, and surface irregularities were recorded and photodocumented. Comparisons were made among the closed dressing groups as well as with a group of historical control subjects treated with open dressings. The ease of application, office time for preparation and application, and cost of the individual dressings were collected. Patient characteristics of overall acceptance, comfort, and ease of maintenance were recorded with a visual analog scale. There were no complications of scarring, surface irregularities, or contact dermatitis from the application or maintenance of the closed dressings. There were no significant differences in the number of days of postoperative erythema or in the rate of facial reepithelialization among the groups. Most patients preferred not to continue with the closed dressings past 2 days. Positive features from the use of closed dressings included reduction in crust formation, decreased pruritus, decreased erythema, and decreased postoperative pain, compared with historical controls. Negative features included time in preparation and application of the dressings. Costs ranged from $9.79 to $50 per dressing change. Closed dressings are safe and offer benefits noted during the first 4 postoperative days. Patients can be expected to maintain a closed dressing for at least 24 hours but no longer than 4 days. The positive features of closed dressings and patient acceptance outweigh the cost and office time involved with their application and maintenance.
Kinematic design to improve ergonomics in human machine interaction.
Schiele, André; van der Helm, Frans C T
2006-12-01
This paper introduces a novel kinematic design paradigm for ergonomic human machine interaction. Goals for optimal design are formulated generically and applied to the mechanical design of an upper-arm exoskeleton. A nine degree-of-freedom (DOF) model of the human arm kinematics is presented and used to develop, test, and optimize the kinematic structure of an human arm interfacing exoskeleton. The resulting device can interact with an unprecedented portion of the natural limb workspace, including motions in the shoulder-girdle, shoulder, elbow, and the wrist. The exoskeleton does not require alignment to the human joint axes, yet is able to actuate each DOF of our redundant limb unambiguously and without reaching into singularities. The device is comfortable to wear and does not create residual forces if misalignments exist. Implemented in a rehabilitation robot, the design features of the exoskeleton could enable longer lasting training sessions, training of fully natural tasks such as activities of daily living and shorter dress-on and dress-off times. Results from inter-subject experiments with a prototype are presented, that verify usability over the entire workspace of the human arm, including shoulder and shoulder girdle.
Amna, Touseef; Hassan, M Shamshi; Yang, Jieun; Khil, Myung-Seob; Song, Ki-Duk; Oh, Jae-Don; Hwang, Inho
2014-01-01
Recently, substantial interest has been generated in using electrospun biomimetic nanofibers of hybrids, particularly organic/inorganic, to engineer different tissues. The present work, for the first time, introduced a unique natural and synthetic hybrid micronanofiber wound dressing, composed of virgin olive oil/copper oxide nanocrystals and polyurethane (PU), developed via facile electrospinning. The as-spun organic/inorganic hybrid micronanofibers were characterized by scanning electron microscopy (SEM), energy dispersive X-ray analysis, X-ray diffraction, electron probe microanalysis, and transmission electron microscopy. The interaction of cells with scaffold was studied by culturing NIH 3T3 fibroblasts on an as-spun hybrid micronanofibrous mat, and viability, proliferation, and growth were assessed. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay results and SEM observation showed that the hybrid micronanofibrous scaffold was noncytotoxic to fibroblast cell culture and was found to benefit cell attachment and proliferation. Hence our results suggest the potential utilization of as-spun micronanoscaffolds for tissue engineering. Copper oxide–olive oil/PU wound dressing may exert its positive beneficial effects at every stage during wound-healing progression, and these micronanofibers may serve diverse biomedical applications, such as tissue regeneration, damaged skin treatment, wound healing applications, etc. Conclusively, the fabricated olive oil–copper oxide/PU micronanofibers combine the benefits of virgin olive oil and copper oxide, and therefore hold great promise for biomedical applications in the near future. PMID:24611006
McDonald, Kyla P.; Ma, Lili
2015-01-01
This research explored whether children judge the knowledge state of others and selectively learn novel information from them based on how they dress. The results indicated that 4- and 6-year-olds identified a formally dressed individual as more knowledgeable about new things in general than a casually dressed one (Study 1). Moreover, children displayed an overall preference to seek help from a formally dressed individual rather than a casually dressed one when learning about novel objects and animals (Study 2). These findings are discussed in relation to the halo effect, and may have important implications for child educators regarding how instructor dress might influence young students’ knowledge attribution and learning preferences. PMID:26636980
Are biopolymers potential deodourising agents in wound management?
Lee, G; Anand, S C; Rajendran, S
2009-07-01
To investigate the odour-adsorbing properties of biopolymers, with a view to using the findings to develop a novel dressing with odour-adsorbing properties. The odour-adsorbing properties of a selection of biopolymers (aloe vera, tea tree oil, neem oil and manuka honey) and three commercially available dressings containing activated charcoal cloth (ACC) were quantitatively assessed using laboratory test equipment. An aloe vera-containing composite dressing, designed and developed by the authors, was also compared with the ACC dressings. Aloe vera was the most adsorbent of the biopolymers and a 40% dilution had comparable values to those of the ACC dressings. Furthermore, values for the novel composite dressing were similar to those of the ACC dressings. The novel composite dressing may be a potential alternative to ACC dressings, and has the added advantages of having antimicrobial properties as well as the ability to promote a moist wound environment. However, more research is needed.
Dressing disrupted: negotiating care through the materiality of dress in the context of dementia.
Buse, Christina; Twigg, Julia
2018-02-01
This paper explores how the materiality of dress mediates and shapes practices of care in the context of dementia. Earlier research called for an approach to conceptualising care that recognised the role played by everyday artefacts. We extend this to a consideration of dress and dressing the body in relation to people with dementia that involves the direct manipulation of material objects, as well as the materiality of bodies. The paper draws on an ESRC funded study Dementia and Dress, which examined experiences of dress for people with dementia, families and care-workers using ethnographic and qualitative methods. Our analysis explores the process of dressing the body, the physicality of guiding and manipulating bodies into clothing, dealing with fabrics and bodies which 'act back' and are resistant to the process of dressing. We consider how the materiality of clothing can constrain or enable practices of care, exploring tensions between garments that support ease of dressing and those that sustain identity. Examining negotiations around dress also reveals tensions between competing 'logics' of care (Mol ). © 2018 The Authors. Sociology of Health & Illness published by John Wiley & Sons Ltd on behalf of Foundation for SHIL.
Effect of periodontal dressings on human gingiva fibroblasts in vitro
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eber, R.M.; Shuler, C.F.; Buchanan, W.
1989-08-01
In vitro cytotoxicity studies of periodontal dressings have not generally produced a result consistent with in vivo observations. These prior in vitro studies have not used human intraoral cell lines. We tested the effects of two eugenol containing and two non-eugenol periodontal dressings on cultured human gingival fibroblasts (HGF) (ATCC No. 1292). Replicate HGF cultures grown in microtiter plates were exposed to stock, 1:4 and 1:16 dilutions of extracts made from each of the four periodontal dressings. The HGF cultures were pulse labelled with tritiated thymidine (3HTdR) after 24, 48, and 72 hours. Incorporations of the labelled thymidine were measuredmore » using liquid scintillation counting and expressed as counts per minute. The results showed that undiluted extracts from all four periodontal dressings totally inhibited 3HTdR uptake (P less than 0.05). The 1:4 dilution of eugenol dressings inhibited 3HTdR uptake significantly more than non-eugenol dressings (P less than 0.05). Interestingly, at 72 hours the 1:16 dilution of the non-eugenol dressings caused significantly increased 3HTdR uptake which was not observed with the eugenol dressings. The present results suggest that the use of a human fibroblastic cell line for testing the effects of periodontal dressings may provide information about the relative biological effects of these dressings. Using this cell line, we have found that eugenol dressings inhibit fibroblast proliferation to a greater extent than non-eugenol dressings.« less
What's the Weather Like Today?
ERIC Educational Resources Information Center
Miller, Heather; Smith, Mandy McCormick; Trundle, Kathy Cabe
2014-01-01
Teaching students to make daily weather observations is one way educators assist them as they learn to dress appropriately. In addition, it provides a natural and developmentally appropriate link between science and other curriculum areas, such as literacy and language development. The "Next Generation Science Standards" (NGSS Lead…
Multi-mode of Four and Six Wave Parametric Amplified Process
NASA Astrophysics Data System (ADS)
Zhu, Dayu; Yang, Yiheng; Zhang, Da; Liu, Ruizhou; Ma, Danmeng; Li, Changbiao; Zhang, Yanpeng
2017-03-01
Multiple quantum modes in correlated fields are essential for future quantum information processing and quantum computing. Here we report the generation of multi-mode phenomenon through parametric amplified four- and six-wave mixing processes in a rubidium atomic ensemble. The multi-mode properties in both frequency and spatial domains are studied. On one hand, the multi-mode behavior is dominantly controlled by the intensity of external dressing effect, or nonlinear phase shift through internal dressing effect, in frequency domain; on the other hand, the multi-mode behavior is visually demonstrated from the images of the biphoton fields directly, in spatial domain. Besides, the correlation of the two output fields is also demonstrated in both domains. Our approach supports efficient applications for scalable quantum correlated imaging.
Multi-mode of Four and Six Wave Parametric Amplified Process.
Zhu, Dayu; Yang, Yiheng; Zhang, Da; Liu, Ruizhou; Ma, Danmeng; Li, Changbiao; Zhang, Yanpeng
2017-03-03
Multiple quantum modes in correlated fields are essential for future quantum information processing and quantum computing. Here we report the generation of multi-mode phenomenon through parametric amplified four- and six-wave mixing processes in a rubidium atomic ensemble. The multi-mode properties in both frequency and spatial domains are studied. On one hand, the multi-mode behavior is dominantly controlled by the intensity of external dressing effect, or nonlinear phase shift through internal dressing effect, in frequency domain; on the other hand, the multi-mode behavior is visually demonstrated from the images of the biphoton fields directly, in spatial domain. Besides, the correlation of the two output fields is also demonstrated in both domains. Our approach supports efficient applications for scalable quantum correlated imaging.
An Overview of the Efficacy of a Next Generation Electroceutical Wound Care Device.
Kim, Hosan; Park, Soon; Housler, Greggory; Marcel, Vanessa; Cross, Sue; Izadjoo, Mina
2016-05-01
Novel approaches including nonpharmacological methodologies for prevention and control of microbial pathogens and emerging antibiotic resistance are urgently needed. Procellera is a wound care device consisting of a matrix of alternating silver (Ag) and zinc (Zn) dots held in position on a polyester substrate with a biocompatible binder. This electroceutical medical device is capable of generating a direct current voltage (0.5-0.9 Volts). Wound dressings containing metals such as Ag and/or Zn as active ingredients are being used for control of colonized and infected wounds. Reports on the presence of electric potential field across epithelium and wound current on wounding have shown that wound healing is enhanced in the presence of an external electrical field. However, majority of the electrical devices require an external power source for delivering pulsed or continuous electric power at the wound site. A microelectric potential-generating system without an external power source is an ideal treatment modality for application in both clinical and field settings. The research presented herein describes efficacy evaluation of a wireless bioelectric dressing against both planktonic and biofilm forms of wound pathogens including multidrug resistant organisms. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Dynamical coupled-channels study of pi N --> pi pi N reactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamano, Hiroyuki; Julia Diaz, Bruno; Lee, Tsung-Shung
2009-01-01
As a step toward performing a complete coupled-channels analysis of the world data of pi N, gamma^* N --> pi N, eta N, pi pi N reactions, the pi N --> pi pi N reactions are investigated starting with the dynamical coupled-channels model developed in Phys. Rev. C76, 065201 (2007). The channels included are pi N, eta N, and pi pi N which has pi Delta, rho N, and sigma N resonant components. The non-resonant amplitudes are generated from solving a set of coupled-channels equations with the meson-baryon potentials defined by effective Lagrangians. The resonant amplitudes are generated from 16more » bare excited nucleon (N^*) states which are dressed by the non-resonant interactions as constrained by the unitarity condition. The available total cross section data of pi^+ p --> pi^+ pi^+ n, pi^+ pi^0 and pi^- p --> pi^+ pi^- n, pi^- pi^0 n, pi^0 pi^0 n can be reproduced to a very large extent both in magnitudes and energy-dependence. Possible improvements of the model are investigated, in p« less
Mahoney, Diane Feeney; Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Mahoney, Edward Leo
2015-01-01
Background Prior research has critiqued the lack of attention to the stressors associated with dementia related dressing issues, stigmatizing patient clothing, and wearable technology challenges. This paper describes the conceptual development and feasibility testing of an innovative ‘smart dresser’ context aware affective system (DRESS) to enable dressing by people with moderate memory loss through individualized audio and visual task prompting in real time. Methods Mixed method feasibility study involving qualitative focus groups with 25 Alzheimer’s family caregivers experiencing dressing difficulties to iteratively inform system design and a quantitative usability trial with 10 healthy subjects in a controlled laboratory setting to assess validity of technical operations. Results Caregivers voiced the need for tangible dressing assistance to reduce their frustration from time spent in repetitive cueing and power struggles over dressing. They contributed 6 changes that influenced the prototype development, most notably adding a dresser top iPad to mimic a familiar ‘TV screen’ for the audio and visual cueing. DRESS demonstrated promising overall functionality, however the validity of identification of dressing status ranged from 0% for the correct pants dressing to 100% for all shirts dressing scenarios. Adjustments were made to the detection components of the system raising the accuracy of detection of all acted dressing scenarios for pants from 50% to 82%. Conclusions Findings demonstrate family caregiver acceptability of the proposed system, the successful interoperability of the built system’s components, and the system’s ability to interpret correct and incorrect dressing actions in controlled laboratory simulations. Future research will advance the system to the alpha stage and subsequent testing with end users in real world settings. PMID:26321895
21 CFR 169.115 - French dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false French dressing. 169.115 Section 169.115 Food and... § 169.115 French dressing. (a) Description. French dressing is the separable liquid food or the..., lecithin, or polyglycerol esters of fatty acids. (d) Nomenclature. The name of the food is “French dressing...
Associations of Early Developmental Milestones with Adult Intelligence
ERIC Educational Resources Information Center
Flensborg-Madsen, Trine; Mortensen, Erik L.
2018-01-01
The study investigated whether age at attainment of 20 developmental milestones within the areas of language, walking, eating, dressing, social interaction, and toilet training was associated with adult intelligence. Mothers of 821 children of the Copenhagen Perinatal Cohort recorded 20 developmental milestones at a 3-year examination, and all…
The School and Home Enrichment Program for Severely Handicapped Children.
ERIC Educational Resources Information Center
Gleason, Joni J.
1987-01-01
The School and Home Enrichment Program for Severely Handicapped Children includes 332 activities. Focus is on the development of sensory responsiveness, eating skills, fine motor skills, gross motor skills, expressive language, receptive language, personal hygiene, dressing, and social interaction that can be used by parents or teachers as a…
AI-Based Chatterbots and Spoken English Teaching: A Critical Analysis
ERIC Educational Resources Information Center
Sha, Guoquan
2009-01-01
The aim of various approaches implemented, whether the classical "three Ps" (presentation, practice, and production) or communicative language teaching (CLT), is to achieve communicative competence. Although a lot of software developed for teaching spoken English is dressed up to raise interaction, its methodology is largely rooted in tradition.…
Cultural Diversity and Information and Communication Impacts on Language Learning
ERIC Educational Resources Information Center
Wang, Wen-Cheng; Lin, Chien-Hung; Chu, Ying-Chien
2011-01-01
Cultural diversity doesn't just entail differences in dress and language. It also encompasses different ways of thinking, managing, and communicating. The relationship between communication and culture is a very complex and intimate one. Cultures are created through communication; that is, communication is the means of human interaction through…
Antimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate
Wibaux, Anne; Thota, Priyaleela; Mastej, Jozef; Prince, Daniel L.; Carty, Neal; Johnson, Peter
2015-01-01
Background Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrated efficacy in clinical settings, the major drawback of high cost and impaired IV insertion site visibility limits their usage. A new, simple film dressing containing CHG within its adhesive layer is now available. The objective of this study was to test the in vitro antimicrobial efficacy of the new dressing in comparison to the CHG-impregnated gel dressing. Methods Quantitative aliquots of suspensions (concentration of 1.0x106 to 5.0x106 cfu/sample) of clinically relevant challenge organisms (Staphylococcus species, gram-negative bacilli, Candida albicans) were incubated in contact with the new CHG-containing film dressing, a placebo version of the same (negative control) and the commercially available CHG-impregnated gel dressing (positive control). Serial dilutions of the surviving organisms were quantified using the pour plate after 1, 3, 5, and 7 days of incubation in order to calculate an antimicrobial log10 reduction for each organism/dressing combination at each point in time. Results The new CHG-containing film dressing delivered greater than 5.0 log10 reduction throughout the 7 days on all aerobic gram-negative bacilli and Staphylococcus species tested. As of day 1 the CHG-containing film dressing provided greater than 5.0 log10 reduction on Candida albicans. There were no statistically significant differences in the log10 reduction between the two dressings tested. Conclusion The new CHG-containing film dressing was found to be as effective as the chlorhexidine gluconate-impregnated gel dressing on clinically relevant microbes. PMID:26599087
NASA Astrophysics Data System (ADS)
Aleksandrova, Irina
2016-01-01
The existing studies, concerning the dressing process, focus on the major influence of the dressing conditions on the grinding response variables. However, the choice of the dressing conditions is often made, based on the experience of the qualified staff or using data from reference books. The optimal dressing parameters, which are only valid for the particular methods and dressing and grinding conditions, are also used. The paper presents a methodology for optimization of the dressing parameters in cylindrical grinding. The generalized utility function has been chosen as an optimization parameter. It is a complex indicator determining the economic, dynamic and manufacturing characteristics of the grinding process. The developed methodology is implemented for the dressing of aluminium oxide grinding wheels by using experimental diamond roller dressers with different grit sizes made of medium- and high-strength synthetic diamonds type ??32 and ??80. To solve the optimization problem, a model of the generalized utility function is created which reflects the complex impact of dressing parameters. The model is built based on the results from the conducted complex study and modeling of the grinding wheel lifetime, cutting ability, production rate and cutting forces during grinding. They are closely related to the dressing conditions (dressing speed ratio, radial in-feed of the diamond roller dresser and dress-out time), the diamond roller dresser grit size/grinding wheel grit size ratio, the type of synthetic diamonds and the direction of dressing. Some dressing parameters are determined for which the generalized utility function has a maximum and which guarantee an optimum combination of the following: the lifetime and cutting ability of the abrasive wheels, the tangential cutting force magnitude and the production rate of the grinding process. The results obtained prove the possibility of control and optimization of grinding by selecting particular dressing parameters.
Forni, Cristiana; D'Alessandro, Fabio; Gambino, Orazio; Amodeo, Alfredo; Pignotti, Elettra; Zanotti, Enrichetta; Tremosini, Morena; Trofa, Carmela; Sabattini, Tania; Matino, Federica; Genco, Rossana; Schiavone, Miguel; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Capezzali, Daniela; Boschi, Rita; Loro, Loretta
2012-01-01
Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC), on the incidence of phlebitis. A randomized controlled trial. The type of dressing could contribute to the incidence of phlebitis, infiltration and accidental removals but the results of the studies are contrasting and samples are limited. To compare the effectiveness of a transparent polyurethane sterile dressing on the rate of phlebitis associated to peripheral venous catheter (PVC) vs a non sterile sticking plaster in use in current practice (standard dressing). Randomized controlled trial. Participants. 1061 PVCs (703 patients, adults and children) at a research orthopedic hospital in the north of Italy; 540 PVCs allocated to receive the sterile and 521 the standard dressing. 96 PVCs were excluded for phlebitis, 48 (9.6%) in the sterile and 48 (10.1%) in the standard dressing group, RR 0.96 (95%CI 0.697 - 1.335). Accidental removal of the PVCs was more frequent with the sterile dressing (9.6% vs 6.3%) but the number of catheters removed without complications was larger in the standard dressing group (48.9% vs 54.9% P=0.0503). Eighty-five PVCs were replaced for detachment of the dressing (50, 9.2% sterile and 35, 6.7% standard dressing). The cheapest transparent sterile dressing costs 32 cents while the standard 9 cents. A sticking non sterile plasters is not influential on the rate of phlebitis and ensures an good fix of the PVC compared the transparent sterile dressing to of polyurethane film.
Nanofibrillar cellulose wound dressing in skin graft donor site treatment.
Hakkarainen, T; Koivuniemi, R; Kosonen, M; Escobedo-Lucea, C; Sanz-Garcia, A; Vuola, J; Valtonen, J; Tammela, P; Mäkitie, A; Luukko, K; Yliperttula, M; Kavola, H
2016-12-28
Although new therapeutic approaches for burn treatment have made progress, there is still need for better methods to enhance wound healing and recovery especially in severely burned patients. Nanofibrillar cellulose (NFC) has gained attention due to its renewable nature, good biocompatibility and excellent physical properties that are of importance for a range of applications in pharmaceutical and biomedical fields. In the present study, we investigated the potential of a wood based NFC wound dressing in a clinical trial on burn patients. Previously, we have investigated NFC as a topical functionalized wound dressing that contributes to improve wound healing in mice. Wood based NFC wound dressing was tested in split-thickness skin graft donor site treatment for nine burn patients in clinical trials at Helsinki Burn Centre. NFC dressing was applied to split thickness skin graft donor sites. The dressing gradually dehydrated and attached to donor site during the first days. During the clinical trials, physical and mechanical properties of NFC wound dressing were optimized by changing its composition. From patient 5 forward, NFC dressing was compared to commercial lactocapromer dressing, Suprathel® (PMI Polymedics, Germany). Epithelialization of the NFC dressing-covered donor site was faster in comparison to Suprathel®. Healthy epithelialized skin was revealed under the detached NFC dressing. NFC dressing self-detached after 11-21days for patients 1-9, while Suprathel® self-detached after 16-28days for patients 5-9. In comparison studies with patients 5-9, NFC dressing self-detached on average 4days earlier compared with Suprathel®. Lower NFC content in the material was evaluated to influence the enhanced pliability of the dressing and attachment to the wound bed. No allergic reaction or inflammatory response to NFC was observed. NFC dressing did not cause more pain for patients than the traditional methods to treat the skin graft donor sites. Based on the preliminary clinical data, NFC dressing seems to be promising for skin graft donor site treatment since it is biocompatible, attaches easily to wound bed, and remains in place until donor site has renewed. It also detaches from the epithelialized skin by itself. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Timsit, Jean-François; Mimoz, Olivier; Mourvillier, Bruno; Souweine, Bertrand; Garrouste-Orgeas, Maïté; Alfandari, Serge; Plantefeve, Gaétan; Bronchard, Régis; Troche, Gilles; Gauzit, Remy; Antona, Marion; Canet, Emmanuel; Bohe, Julien; Lepape, Alain; Vesin, Aurélien; Arrault, Xavier; Schwebel, Carole; Adrie, Christophe; Zahar, Jean-Ralph; Ruckly, Stéphane; Tournegros, Caroline; Lucet, Jean-Christophe
2012-12-15
Most vascular catheter-related infections (CRIs) occur extraluminally in patients in the intensive care unit (ICU). Chlorhexidine-impregnated and strongly adherent dressings may decrease catheter colonization and CRI rates. To determine if chlorhexidine-impregnated and strongly adherent dressings decrease catheter colonization and CRI rates. In a 2:1:1 assessor-masked randomized trial in patients with vascular catheters inserted for an expected duration of 48 hours or more in 12 French ICUs, we compared chlorhexidine dressings, highly adhesive dressings, and standard dressings from May 2010 to July 2011. Coprimary endpoints were major CRI with or without catheter-related bloodstream infection (CR-BSI) with chlorhexidine versus nonchlorhexidine dressings and catheter colonization rate with highly adhesive nonchlorhexidine versus standard nonchlorhexidine dressings. Catheter-colonization, CR-BSIs, and skin reactions were secondary endpoints. A total of 1,879 patients (4,163 catheters and 34,339 catheter-days) were evaluated. With chlorhexidine dressings, the major-CRI rate was 67% lower (0.7 per 1,000 vs. 2.1 per 1,000 catheter-days; hazard ratio [HR], 0.328; 95% confidence interval [CI], 0.174-0.619; P = 0.0006) and the CR-BSI rate 60% lower (0.5 per 1,000 vs. 1.3 per 1,000 catheter-days; HR, 0.402; 95% CI, 0.186-0.868; P = 0.02) than with nonchlorhexidine dressings; decreases were noted in catheter colonization and skin colonization rates at catheter removal. The contact dermatitis rate was 1.1% with and 0.29% without chlorhexidine. Highly adhesive dressings decreased the detachment rate to 64.3% versus 71.9% (P < 0.0001) and the number of dressings per catheter to two (one to four) versus three (one to five) (P < 0.0001) but increased skin colonization (P < 0.0001) and catheter colonization (HR, 1.650; 95% CI, 1.21-2.26; P = 0.0016) without influencing CRI or CR-BSI rates. A large randomized trial demonstrated that chlorhexidine-gel-impregnated dressings decreased the CRI rate in patients in the ICU with intravascular catheters. Highly adhesive dressings decreased dressing detachment but increased skin and catheter colonization. Clinical trial registered with www.clinicaltrials.gov (NCT 01189682).
N-formylation of amines via the aerobic oxidation of methanol over supported gold nanoparticles.
Ishida, Tamao; Haruta, Masatake
2009-01-01
Dress code: formyl. Gold nanoparticles supported on NiO catalyze the one-pot N-formylation of amines with methanol and molecular oxygen to produce formamide at a selectivity of 90 %. This process generates methyl formate in situ, followed by reaction with amines.
USDA-ARS?s Scientific Manuscript database
Nonwoven UltraCleanTM Cotton (highly cleaned and hydroentangled, greige cotton) retains the native wax and pectin content (~2%) of the cotton fiber traditionally removed from scoured and bleached cotton gauze, yet potentially affording wound healing properties. In vitro thromboelastography, hydrog...
... as much gauze or packing gauze. Removing the Old Dressing Follow these steps to remove your dressing: ... sterile gloves. Carefully remove the tape. Remove the old dressing. If it is sticking to your skin, ...
A prospective randomized clinical trial to evaluate methods of postoperative care of hypospadias.
McLorie, G; Joyner, B; Herz, D; McCallum, J; Bagli, D; Merguerian, P; Khoury, A
2001-05-01
Hypospadias repair is a common operation performed by pediatric urologists. Perhaps the greatest variable and source of controversy of postoperative care is the surgical dressing. We hypothesized that using no dressing would achieve surgically comparable results to those traditionally achieved by a postoperative dressing and it would also simplify postoperative parent delivered home care. Accordingly we designed a prospective randomized clinical trial to compare surgical outcome and postoperative care after hypospadias repair in boys with no dressing and those who received 1 of the 2 most common types of dressing. In a 12-month period 120 boys with an average age of 2.2 years underwent primary 1-stage hypospadias repair at a single center with 4 participating surgeons. Repair was performed in 60 boys with proximal and 60 with distal hypospadias on an outpatient basis. Ethics and Internal Review Board approval, and informed consent were obtained. Boys were then prospectively randomized to receive no dressing, an adhesive biomembrane dressing or a compressive wrap dressing. Comprehensive instructions on postoperative care were distributed to all families and a questionnaire was distributed to the parents at the initial followup. Surgical outcome was evaluated and questionnaire responses were analyzed. Fisher's exact test was done to test the significance of differences in surgical outcomes and questionnaire responses. A total of 117 boys completed the prospective randomized trial. Surgical staff withdrew 3 cases from randomized selection to place a dressing for postoperative hemostasis. We obtained 101 questionnaires for response analysis. The type or absence of the dressing did not correlate with the need for repeat procedures, urethrocutaneous fistula, or meatal stenosis or regression. Analysis revealed less narcotic use in the no dressing group and fewer telephone calls to the urology nurse, or on-call resident and/or fellow. These findings were statistically significant. In addition, there were more unscheduled visits to the urology clinic, emergency room or primary physician office by boys with than without a dressing. Furthermore, 29% of the parents were not psychologically prepared to remove the dressing and 12% were so reluctant that the dressing was removed at the urology outpatient clinic. The surgical outcome and rate of adverse events or complications were not compromised without a postoperative dressing. An absent dressing simplified postoperative ambulatory parent delivered home care. We recommend that dressings should be omitted from routine use after hypospadias repair.
D-brane instantons and the effective field theory of flux compactifications
NASA Astrophysics Data System (ADS)
Uranga, Angel M.
2009-01-01
We provide a description of the effects of fluxes on euclidean D-brane instantons purely in terms of the 4d effective action. The effect corresponds to the dressing of the effective non-perturbative 4d effective vertex with 4d flux superpotential interactions, generated when the moduli fields made massive by the flux are integrated out. The description in terms of effective field theory allows a unified description of non-perturbative effects in all flux compactifications of a given underlying fluxless model, globally in the moduli space of the latter. It also allows us to describe explicitly the effects on D-brane instantons of fluxes with no microscopic description, like non-geometric fluxes. At the more formal level, the description has interesting connections with the bulk-boundary map of open-closed two-dimensional topological string theory, and with the Script N = 1 special geometry.
NASA Astrophysics Data System (ADS)
Wang, Jian-ming; Xu, Xue-xiang
2018-04-01
Using dressed state method, we cleverly solve the dynamics of atom-field interaction in the process of two-photon absorption and emission between atomic levels. Here we suppose that the atom is initially in the ground state and the optical field is initially in Fock state, coherent state or thermal state, respectively. The properties of the atom, including the population in excited state and ground state, the atom inversion, and the properties for optical field, including the photon number distribution, the mean photon number, the second-order correlation function and the Wigner function, are discussed in detail. We derive their analytical expressions and then make numerical analysis for them. In contrast with Jaynes-Cummings model, some similar results, such as quantum Rabi oscillation, revival and collapse, are also exhibit in our considered model. Besides, some novel nonclassical states are generated.
Evaluation of a foam dressing for acute and chronic wound exudate management.
Bullough, Lindsay; Johnson, Sue; Forder, Rebecca
2015-09-01
This article discusses the use of a foam dressing for exudate management in both chronic and acute wounds, such as surgical wounds, pressure ulcers, diabetic ulcers, trauma wounds, and leg ulcers. The primary objective of the study was to observe patients' wound progression in terms of wound size and the condition of the wound bed, when using this foam dressing as either a primary or secondary dressing. The outcome of the evaluation demonstrated that ActivHeal Foam Contact dressing effectively managed exudate. It was also observed that the dressing can assist in autolysis and support improvements in peri-wound status. Choosing an appropriate dressing to manage a wound is essential. Clinicians working in the NHS are under pressure to deliver good-quality clinical outcomes, and the ActivHeal Foam Contact dressing supports this outcome.
Burleson, Winslow; Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-05-01
Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). This laboratory study evaluated the DRESS prototype's capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing-typical issues that challenge a PWD and their caregivers. A set of expected detections for correct dressing was prepared via video analysis of all participants' dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype's ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype's reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. ©Winslow Burleson, Cecil Lozano, Vijay Ravishankar, Jisoo Lee, Diane Mahoney. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 01.05.2018.
Evaluation of dressings used with local anaesthetic cream and for peripheral venous cannulation.
Needham, Rowan; Strehle, Eugen-Matthias
2008-10-01
To compare four polyurethane dressings manufactured by two different companies for use in children. Seventy-eight dressings were applied to secure either local anaesthetic creams (n = 62) or intravenous cannulae (n = 16). Each dressing was evaluated for ease of application, security and ease of removal, using a simple scoring system. 84 per cent of Opsite flexigrid and 90 per cent of Tegaderm local anaesthetic cream dressings were rated as easy or very easy to apply. Opsite flexigrid was felt to be more secure, whereas Tegaderm was easier to remove. The Tegaderm cannula dressing was easier to apply than the iv3000 dressing. There was little difference between the two brands, including costs.
ERIC Educational Resources Information Center
Griffiths, Noola K.
2010-01-01
This study investigates the effects of concert dress and physical appearance on perceptions of female classical soloists' musical abilities over a range of genres. Four female violinists were recorded playing three pieces, in four styles of dress of varying formality. Each combination of performer, piece and dress was recorded twice, once as the…
Use of wound dressings with soft silicone adhesive technology.
Morris, Clare; Emsley, Paulene; Marland, Elizabeth; Meuleneire, Frans; White, Richard
2009-04-01
To evaluate how pain, during and in-between dressing changes, is affected by the introduction of Mepilex Border Lite, a wound dressing manufactured by Mölnlycke Health Care using Safetac soft silicone adhesive technology, to the treatment of different types of paediatric wounds/skin injuries. Wounds/skin injuries that met the criteria for inclusion in the study were dressed with Mepilex Border Lite. Patients were followed for six weeks or until their wounds/skin injuries had healed, whichever occurred earlier. At each dressing change, pain severity before and during dressing removal was rated by the patient and the investigator on a scale from zero (no pain at all) to ten (worst pain ever). Other variables measured included: signs of trauma to wound/skin injury and surrounding skin, the proportion of viable/non-viable tissue, the quantity and appearance of exudate, odour, and clinical signs of infection. At the final dressing change, patients and investigators completed questionnaires to rate the dressing performance. Mean pain severity scores were significantly lower (p < or = 0.003) at the first dressing change than at baseline. Over 99.5 per cent of the Mepilex Border Lite dressing changes were reported to be atraumatic and more than half of the wounds healed within the study period. Conformability, ease of use, ease of removal, patient comfort, and overall experience with the dressing were rated as 'good' to 'very good' at the vast majority of final visit evaluations. This study provides further evidence of the ability of dressings with Safetac soft silicone adhesive technology to minimise trauma and pain and demonstrates the ability of Mepilex Border Lite to overcome the clinical challenges associated with the use of dressings on the wounds/skin injuries of paediatric patients.
Zehrer, Cindy L; Holm, David; Solfest, Staci E; Walters, Shelley-Ann
2014-12-01
This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. Mean upright MVTR for the reformulated dressing was 980 g/m(2) /24 hours and was significantly different than all of the comparator dressings (P < 0·0001), which ranged from 80 to 1620 g/m(2) /24 hours (three higher/three lower). The reformulated dressing median wear time ranged from 6·1 to >7·0 days, compared with 1·0 to 3·5 days for the comparator dressings (P = 0·0012 to P < 0·0001). The median fluid volume handled ranged from 78·0 to >87 ml compared with 13·0 to 44·5 ml for the comparator dressings (P = 0·0007 to P < 0·001). Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Andreu, Vanesa; Mendoza, Gracia; Arruebo, Manuel; Irusta, Silvia
2015-01-01
A fast and effective wound healing process would substantially decrease medical costs, wound care supplies, and hospitalization significantly improving the patients’ quality of life. The search for effective therapeutic approaches seems to be imperative in order to avoid the aggravation of chronic wounds. In spite of all the efforts that have been made during the recent years towards the development of artificial wound dressings, none of the currently available options combine all the requirements necessary for quick and optimal cutaneous regeneration. Therefore, technological advances in the area of temporary and permanent smart dressings for wound care are required. The development of nanoscience and nanotechnology can improve the materials and designs used in topical wound care in order to efficiently release antimicrobial, anti-inflammatory and regenerative compounds speeding up the endogenous healing process. Nanostructured dressings can overcome the limitations of the current coverings and, separately, natural origin components can also overcome the drawbacks of current antibiotics and antiseptics (mainly cytotoxicity, antibiotic resistance, and allergies). The combination of natural origin components with demonstrated antibiotic, regenerative, or anti-inflammatory properties together with nanostructured materials is a promising approach to fulfil all the requirements needed for the next generation of bioactive wound dressings. Microbially compromised wounds have been treated with different essential oils, honey, cationic peptides, aloe vera, plant extracts, and other natural origin occurring antimicrobial, anti-inflammatory, and regenerative components but the available evidence is limited and insufficient to be able to draw reliable conclusions and to extrapolate those findings to the clinical practice. The evidence and some promising preliminary results indicate that future comparative studies are justified but instead of talking about the beneficial or inert effects of those natural origin occurring materials, the scientific community leads towards the identification of the main active components involved and their mechanism of action during the corresponding healing, antimicrobial, or regenerative processes and in carrying out systematic and comparative controlled tests. Once those natural origin components have been identified and their efficacy validated through solid clinical trials, their combination within nanostructured dressings can open up new avenues in the fabrication of bioactive dressings with outstanding characteristics for wound care. The motivation of this work is to analyze the state of the art in the use of different essential oils, honey, cationic peptides, aloe vera, plant extracts, and other natural origin occurring materials as antimicrobial, anti-inflammatory and regenerative components with the aim of clarifying their potential clinical use in bioactive dressings. We conclude that, for those natural occurring materials, more clinical trials are needed to reach a sufficient level of evidence as therapeutic agents for wound healing management. PMID:28793497
Napavichayanun, Supamas; Yamdech, Rungnapha; Aramwit, Pornanong
2016-03-01
In our previous work, we have attempted to develop a novel bacterial nanocellulose wound dressing which composed of both polyhexamethylene biguanide (PHMB) as an antimicrobial agent and sericin as an accelerative wound healing component. The loading sequence and concentration of PHMB and sericin were optimized to provide the wound dressing with the most effective antimicrobial activity and enhanced collagen production. In this study, further in vitro, in vivo, and clinical studies of this novel wound dressing were performed to evaluate its safety, efficacy, and applicability. For the in vitro cytotoxic test with L929 mouse fibroblast cells, our novel dressing was not toxic to the cells and also promoted cell migration as good as the commercially available dressing, possibly due to the component of sericin released. When implanted subcutaneously in rats, the lower inflammation response was observed for the novel dressing implanted, comparing to the commercially available dressing. This might be that the antimicrobial PHMB component of the novel dressing played a role to reduce infection and inflammation reaction. The clinical trial patch test was performed on the normal skin of healthy volunteers to evaluate the irritation effect of the dressing. Our novel dressing did not irritate the skin of any volunteers, as characterized by the normal levels of erythema and melanin and the absence of edema, papule, vesicle, and bullae. Then, the novel dressing was applied for the treatment of full-thickness wounds in rats. The wounds treated with our novel dressing showed significantly lower percentage of wound size and higher extent of collagen formation mainly due to the activity of sericin. We concluded that our novel bacterial nanocellulose incorporating PHMB and sericin was a safe and efficient wound dressing material for further investigation in the wound healing efficacy in clinic.
Dressing the post-Newtonian two-body problem and classical effective field theory
NASA Astrophysics Data System (ADS)
Kol, Barak; Smolkin, Michael
2009-12-01
We apply a dressed perturbation theory to better organize and economize the computation of high orders of the 2-body effective action of an inspiralling post-Newtonian (PN) gravitating binary. We use the effective field theory approach with the nonrelativistic field decomposition (NRG fields). For that purpose we develop quite generally the dressing theory of a nonlinear classical field theory coupled to pointlike sources. We introduce dressed charges and propagators, but unlike the quantum theory there are no dressed bulk vertices. The dressed quantities are found to obey recursive integral equations which succinctly encode parts of the diagrammatic expansion, and are the classical version of the Schwinger-Dyson equations. Actually, the classical equations are somewhat stronger since they involve only finitely many quantities, unlike the quantum theory. Classical diagrams are shown to factorize exactly when they contain nonlinear worldline vertices, and we classify all the possible topologies of irreducible diagrams for low loop numbers. We apply the dressing program to our post-Newtonian case of interest. The dressed charges consist of the dressed energy-momentum tensor after a nonrelativistic decomposition, and we compute all dressed charges (in the harmonic gauge) appearing up to 2PN in the 2-body effective action (and more). We determine the irreducible skeleton diagrams up to 3PN and we employ the dressed charges to compute several terms beyond 2PN.
Cost of dressings for prevention of sacral pressure ulcers.
Inoue, Kelly Cristina; Matsuda, Laura Misue
2016-01-01
to identify costs of dressings to prevent sacral pressure ulcers in an adult intensive care unit in Paraná, Brazil. secondary analysis study with 25 patients admitted between October 2013 and March 2014, using transparent polyurethane film (n=15) or hydrocolloid dressing (n=10) on the sacral region. The cost of each intervention was based on the unit amount used in each type of dressing, and its purchase price (transparent film = R$15.80, hydrocolloid dressing = R$68.00). the mean cost/patient was R$23.17 for use of transparent film and R$190.40 for use of hydrocolloid dressing. The main reason for changing the dressing was detachment. the transparent film was the most economically advantageous alternative to prevent sacral pressure ulcers in critical care patients. However, additional studies should be carried out including assessment of the effectiveness of both dressings.
Genuino, Glenn Angelo S; Baluyut-Angeles, Kathrina Victoria; Espiritu, Andre Paolo T; Lapitan, Marie Carmela M; Buckley, Brian S
2014-11-01
Non-extensive superficial partial thickness burns constitute a major proportion of burns. Conventional treatment involves regular changing of absorptive dressings including the application of a topical antimicrobial, commonly silver sulfadiazine. A systematic review has found insufficient evidence to support or refute such antimicrobial prophylaxis. Another review compared silver sulfadiazine dressings with other occlusive and non-antimicrobial dressings and found insufficient evidence to guide practice. Other research has suggested that dressings with petrolatum gel are as effective as silver sulfadiazine. Single-center, randomized, controlled parallel group trial comparing conventional silver sulfadiazine dressings with treatment with petrolatum gel alone. Consenting adults 18-45 years old with superficial partial thickness burns≤10% total body surface area seen within 24h of the injury were randomized to daily dressing either with petrolatum gel without top dressings or conventional silver sulfadiazine treatment with gauze dressings. Primary outcomes were blinded assessment of time to complete re-epithelialization, wound infection or allergic contact dermatitis. Secondary outcomes included assessment of ease, time and pain of dressing changes. 26 patients were randomized to petrolatum and 24 to silver sulfadiazine dressings. Follow up data available for 19 in each group. Mean time to re-epithelialization was 6.2 days (SD 2.8) in the petrolatum group and 7.8 days (SD 2.1) in the silver sulfadiazine group (p=0.050). No wound infection or dermatitis was observed in either group. Scores for adherence to wound, ease of dressing removal and time required to change dressings were significantly better in the petrolatum treatment arm (p<0.01). Petrolatum gel without top dressings may be at least as effective as silver sulfadiazine gauze dressings with regard to time to re-epithelialization, and incidence of infection and allergic contact dermatitis. Petrolatum gel appears to be an effective, affordable and widely available alternative in the treatment of minor superficial partial thickness burns in adults. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Kent, Dea J
2010-01-01
I compared the effects of a just-in-time educational intervention (educational materials for dressing application attached to the manufacturer's dressing package) to traditional wound care education on reported confidence and dressing application in a simulated model. Nurses from a variety of backgrounds were recruited for this study. The nurses possessed all levels of education ranging from licensed practical nurse to master of science in nursing. Both novice and seasoned nurses were included, with no stipulations regarding years of nursing experience. Exclusion criteria included nurses who spent less than 50% of their time in direct patient care and nurses with advanced wound care training and/or certification (CWOCN, CWON). Study settings included community-based acute care facilities, critical access hospitals, long-term care facilities, long-term acute care facilities, and home care agencies. No level 1 trauma centers were included in the study for geographical reasons. Participants were randomly allocated to control or intervention groups. Each participant completed the Kent Dressing Confidence Assessment tool. Subjects were then asked to apply the dressing to a wound model under the observation of either the principal investigator or a trained observer, who scored the accuracy of dressing application according to established criteria. None of the 139 nurses who received traditional dressing packaging were able to apply the dressing to a wound model correctly. In contrast, 88% of the nurses who received the package with the educational guide attached to it were able to apply the dressing to a wound model correctly (χ2 = 107.22, df = 1, P = .0001). Nurses who received the dressing package with the attached educational guide agreed that this feature gave them confidence to correctly apply the dressing (88%), while no nurse agreed that the traditional package gave him or her the confidence to apply the dressing correctly (χ2 = 147.47, df = 4, P < .0001). A just-in-time education intervention improved nurses' confidence when applying an unfamiliar dressing and accuracy of application when applying the dressing to a simulated model compared to traditional wound care education.
Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations.
Wu, Stephanie; Applewhite, Andrew J; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry
2017-11-01
Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. A 2-day panel meeting convened in February 2017. Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed.
Oxidized Regenerated Cellulose/Collagen Dressings: Review of Evidence and Recommendations
Wu, Stephanie; Applewhite, Andrew J.; Niezgoda, Jeffrey; Snyder, Robert; Shah, Jayesh; Cullen, Breda; Schultz, Gregory; Harrison, Janis; Hill, Rosemary; Howell, Melania; Speyrer, Marcus; Utra, Howard; de Leon, Jean; Lee, Wayne; Treadwell, Terry
2017-01-01
ABSTRACT OBJECTIVE: Healthcare systems are being challenged to manage increasing numbers of nonhealing wounds. Wound dressings are one of the first lines of defense in wound management, and numerous options exist. The oxidized regenerated cellulose (ORC)/collagen dressing may offer healthcare providers a robust and cost-effective tool for use in a variety of wounds. DESIGN: A multidisciplinary panel meeting was convened to discuss the use of ORC/collagen dressings in wound care and provide practice recommendations. A literature search was conducted to provide a brief review of the peer-reviewed studies published between January 2000 and March 2016 to inform the meeting. SETTING: A 2-day panel meeting convened in February 2017. PARTICIPANTS: Healthcare providers with experience using ORC/collagen dressings. This multidisciplinary panel of 15 experts in wound healing included podiatrists, wound care specialists (doctors, certified wound care nurses, and research scientists), and an orthopedist. RESULTS: The literature search identified 58 articles, a majority of which were low levels of evidence (69.3% were level 3 or lower). Panel members identified wound types, such as abrasions, burns, stalled wounds, diabetic foot ulcers, and pressure injuries, where ORC/collagen dressing use could be beneficial. Panel members then provided recommendations and technical pearls for the use of ORC/collagen dressings in practice. Barriers to ORC/collagen dressing use were discussed, and potential resolutions were offered. CONCLUSIONS: An ORC/collagen dressing can be a critical tool for clinicians to help manage a variety of wounds. Clinical and economic studies comparing standard-of-care dressings and plain collagen dressings to ORC/collagen dressings are needed. PMID:29049055
Economics of pressure-ulcer care: review of the literature on modern versus traditional dressings.
San Miguel, L; Torra i Bou, J E; Verdú Soriano, J
2007-01-01
Published evidence suggests that some of the benefits of modern dressings--longer wear times and less frequent dressing changes--make them more cost-effective than traditional gauze dressings in pressure ulcer management.
Watson, Denis; Bergquist, Stephen; Nicholson, Julie; Norrie, David H
2017-06-28
While Manuka honey in vitro is strongly antimicrobial, there have been, to the best of the authors' knowledge, no studies showing that dressings impregnated with Manuka honey can kill organisms in the dressing itself. The investigators used the American Association of Textile Chemists and Colorists' 100 test methodology to compare honey-impregnated dressings with control dressings (without honey) on the ability to kill common wound pathogens. Organisms were chosen after a review of the causal organisms found in actual wound infections over a 12-month period in a busy outpatient wound clinic. Even when the dressings were challenged daily with further inoculated organisms, > 5-log reductions were routinely noted across a range of pathogens, including multiple drug-resistant species using dressings containing Manuka honey relative to the control. The results presented herein show that when well-characterized medical-grade Manuka honey is used in dressings (ie, a minimum of 400 mg methylglyoxal/kg) these dressings can comprehensively kill common wound pathogens associated with infected wounds.
Phase diagram and thermal properties of strong-interaction matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Fei; Chen, Jing; Liu, Yu-Xin
2016-05-20
We introduce a novel method for computing the (μ, T)-dependent pressure in continuum QCD, from which we obtain a complex phase diagram and predictions for thermal properties of the dressed-quark component of the system, providing the in-medium behavior of the related trace anomaly, speed of sound, latent heat, and heat capacity.
Media/Visual Literacy Art Education: Sexism in Hip-Hop Music Videos
ERIC Educational Resources Information Center
Chung, Sheng Kuan
2007-01-01
Media programs like hip-hop music videos are powerful aesthetic agents that inspire teenagers. Thus, they have tremendous influence on young people's identity formation, lifestyle choices, and knowledge construction which are manifested in the ways teens dress, express themselves, behave, and interact with each other. However, because of the…
Revealing dressed quarks via the proton's charge distribution.
Cloët, Ian C; Roberts, Craig D; Thomas, Anthony W
2013-09-06
The proton is arguably the most fundamental of nature's readily detectable building blocks. It is at the heart of every nucleus and has never been observed to decay. It is nevertheless a composite object, defined by its valence-quark content: u+u+d--i.e., two up (u) quarks and one down (d) quark; and the manner by which they influence, inter alia, the distribution of charge and magnetization within this bound state. Much of novelty has recently been learned about these distributions; and it now appears possible that the proton's momentum-space charge distribution possesses a zero. Experiments in the coming decade should answer critical questions posed by this and related advances; we explain how such new information may assist in charting the origin and impact of key emergent phenomena within the strong interaction. Specifically, we show that the possible existence and location of a zero in the proton's electric form factor are a measure of nonperturbative features of the quark-quark interaction in the standard model, with particular sensitivity to the running of the dressed-quark mass.
Lozano, Cecil; Ravishankar, Vijay; Lee, Jisoo; Mahoney, Diane
2018-01-01
Background Individuals living with advancing stages of dementia (persons with dementia, PWDs) or other cognitive disorders do not have the luxury of remembering how to perform basic day-to-day activities, which in turn makes them increasingly dependent on the assistance of caregivers. Dressing is one of the most common and stressful activities provided by caregivers because of its complexity and privacy challenges posed during the process. Objective In preparation for in-home trials with PWDs, the aim of this study was to develop and evaluate a prototype intelligent system, the DRESS prototype, to assess its ability to provide automated assistance with dressing that can afford independence and privacy to individual PWDs and potentially provide additional freedom to their caregivers (family members and professionals). Methods This laboratory study evaluated the DRESS prototype’s capacity to detect dressing events. These events were engaged in by 11 healthy participants simulating common correct and incorrect dressing scenarios. The events ranged from donning a shirt and pants inside out or backwards to partial dressing—typical issues that challenge a PWD and their caregivers. Results A set of expected detections for correct dressing was prepared via video analysis of all participants’ dressing behaviors. In the initial phases of donning either shirts or pants, the DRESS prototype missed only 4 out of 388 expected detections. The prototype’s ability to recognize other missing detections varied across conditions. There were also some unexpected detections such as detection of the inside of a shirt as it was being put on. Throughout the study, detection of dressing events was adversely affected by the relatively smaller effective size of the markers at greater distances. Although the DRESS prototype incorrectly identified 10 of 22 cases for shirts, the prototype preformed significantly better for pants, incorrectly identifying only 5 of 22 cases. Further analyses identified opportunities to improve the DRESS prototype’s reliability, including increasing the size of markers, minimizing garment folding or occlusions, and optimal positioning of participants with respect to the DRESS prototype. Conclusions This study demonstrates the ability to detect clothing orientation and position and infer current state of dressing using a combination of sensors, intelligent software, and barcode tracking. With improvements identified by this study, the DRESS prototype has the potential to provide a viable option to provide automated dressing support to assist PWDs in maintaining their independence and privacy, while potentially providing their caregivers with the much-needed respite. PMID:29716885
Effects of adhesive dressings on stratum corneum conductance.
Cavallini, Maurizio; Gazzola, Riccardo; Vaienti, Luca
2012-05-01
Stratum corneum is a fundamental layer of epidermis. It acts as a barrier, with antimicrobial features, regulating skin permeability and integrity as well. Adhesive dressings and their removal could alter this layer, affecting cutaneous water balance and lipid composition of stratum corneum. These changes could be monitored by measurement of cutaneous hydration. Ninety-two patients affected by wounds dressed with adhesive tapes or plasters have been studied. Measurement of skin conductance under tape/plaster and in the surrounding healthy skin, immediately after removal of dressing has been performed. Dressing age, wound localization, and characteristics were also considered. Adhesive dressings alter significantly stratum corneum conductance. Although healthy skin hydration has significant variations throughout the body, cutaneous conductance under adhesive dressing in different areas displays no significative changes. Moreover, the increase in hydration due to adhesive tapes/plasters showed no association with wound dehiscence. Adhesive dressings cause a significative increase in stratum corneum conductance, acting as a barrier to apocrine secretions. Although different hydration levels have been observed in healthy skin throughout the body, no difference exists under adhesive dressing among different regions, suggesting no contraindications in their employment throughout the body. Increase in cutaneous hydration showed no correlations with wound dehiscence, thus confirming safety and practicality of these dressings. © 2011 John Wiley & Sons A/S.
Percy, Dean B; Haddock, Candace; Ma, Vivian; Nowak, Amie; Panczuk, Julia; Butterworth, Sonia
2018-05-01
The purpose of this study was to describe outcomes and resource utilization in patients treated with twice-weekly silver impregnated (SI) nanocrystalline dressings for initial non-operative management of giant omphalocele (GO). A retrospective review of patients with GO treated with SI dressings was undertaken. Clinical parameters, cost, and complications were recorded. Five patients with GO were treated with SI dressings between 2014 and 2016. Clinical characteristic (mean ± SD) included gestational age 36 ± 4 weeks, birth weight 2.6 ± 0.63 kg, GO size 10.2 ± 4.7 cm, ventilator days 7.5 ± 8.7 d, days in NICU 41 ± 20 d, days to full feeds, 30 ± 15 d, and LOS 62 ± 41 d. The average in-hospital cost of SI dressings was $110 CAD/week. This is comparable to daily silver sulfadiazine dressings ($109CAD/week) which were used historically. All patients were discharged with once- or twice-weekly dressing changes. No ruptures occurred. There was one mortality secondary to pulmonary sepsis. For initial non-operative management of GO, twice weekly SI nanocrystalline dressings is safe and effective. Use of SI dressings results in decreased handling of infants, reduced physician and nursing resource utilization, and favourable outcomes. IV (Retrospective Case Series). Copyright © 2018. Published by Elsevier Inc.
Dorafshar, Amir H; Franczyk, Mieczyslawa; Gottlieb, Lawrence J; Wroblewski, Kristen E; Lohman, Robert F
2012-07-01
Two methods of subatmospheric pressure wound therapy--wall suction applied to a sealed gauze dressing (GSUC) and the vacuum-assisted closure device (VAC)--were compared in hospitalized patients at University of Chicago Medical Center. VAC therapy is widely used, but can be expensive and difficult to apply; it also fails in some patients. A randomized prospective study of 87 patients (N = 45 in the GSUC arm and N = 42 in the VAC arm) was undertaken between October 2006 and May 2008. The study comprised patients with acute wounds resulting from trauma, dehiscence, or surgery. Demographics and wound characteristics were similar in both groups. There were significant reductions in wound surface area and volume in each group. In the GSUC group, the reductions in wound surface area and volume were 4.5%/day and 8.4%/day, respectively (P < 0.001 for both), and in the VAC group, this was 4.9%/day and 9.8%/day, respectively (P < 0.001 for both). The reductions in wound surface area and volume were similar in both groups (P = 0.60 and 0.19, respectively, for the group-by-time interaction). The estimated difference (VAC - GSUC) was 0.4% (95% confidence interval: -1.0, 1.7) for wound surface area and 1.4% (95% confidence interval: -0.7, 3.5) for volume. The mean cost per day for GSUC therapy was $4.22 versus $96.51 for VAC therapy (P < 0.01) and the average time required for a GSUC dressing change was 19 minutes versus 31 minutes for a VAC dressing change (P < 0.01). The sum of pain intensity differences was 0.50 in the GSUC group compared with 1.73 for the VAC group (P = 0.02). GSUC is noninferior to VAC with respect to changes in wound volume and surface area in an acute care setting. In addition, GSUC dressings were easier to apply, less expensive, and less painful.
Cardiac pacemaker dysfunction in children after thoracic drainage catheter manipulation.
Lobdell, K W; Walters, H L; Hudson, C; Hakimi, M
1997-05-01
Two children underwent placement of permanent, epicardial-lead, dual-chamber, unipolar pacemaker systems for complete heart block. Postoperatively, both patients demonstrated subcutaneous emphysema-in the area of their pulse generators-temporally related to thoracic catheter manipulation. Acutely, each situation was managed with manual compression of the pulse generator, ascertaining appropriate pacemaker sensing and pacing. Maintenance of compression with pressure dressings, vigilant observation/monitoring, and education of the care givers resulted in satisfactory pacemaker function without invasive intervention.
Hua, Yun; Qiu, Rong; Yao, Wen-Yan; Zhang, Qin; Chen, Xiao-Li
2015-10-01
It has been demonstrated that patients with chronic wounds experience the most pain during dressing changes. Currently, researchers focus mostly on analgesics and appropriate dressing materials to relieve pain during dressing changes of chronic wounds. However, the effect of nonpharmacologic interventions, such as virtual reality distraction, on pain management during dressing changes of pediatric chronic wounds remains poorly understood. To investigate the effect of virtual reality distraction on alleviating pain during dressing changes in children with chronic wounds on their lower limbs. A prospective randomized study. A pediatric center in a tertiary hospital. Sixty-five children, aged from 4 to 16 years, with chronic wounds on their lower limbs. Pain and anxiety scores during dressing changes were recorded by using the Wong-Baker Faces picture scale, visual analogue scale, and pain behavior scale, as well as physiological measurements including pulse rate and oxygen saturation. Time length of dressing change was recorded. Virtual reality distraction significantly relieved pain and anxiety scores during dressing changes and reduced the time length for dressing changes as compared to standard distraction methods. The use of virtual reality as a distraction tool in a pediatric ward offered superior pain reduction to children as compared to standard distractions. This device can potentially improve clinical efficiency by reducing length time for dressing changes. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Kissen, Rita M.
During the past 40 years, several generations of American children have grown up with the Nation of Israel as a historical reality. Whether Jewish or Gentile, juvenile readers have absorbed a version of the story that recapitulates in modern dress the biblical story of the children of Hagar and Sarah, reinforced by American attitudes toward people…
An Inexpensive Bismuth-Petrolatum Dressing for Treatment of Burns
Chattopadhyay, Arhana; Chang, Kathleen; Nguyen, Khoa; Galvez, Michael G.; Legrand, Anais; Davis, Christopher; McGoldrick, Rory; Long, Chao; Pham, Hung
2016-01-01
Background: Xeroform remains the current standard for treating superficial partial-thickness burns but can be prohibitively expensive in developing countries with prevalent burn injuries. This study (1) describes the production of an alternative low-cost dressing and (2) compares the alternative dressing and Xeroform using the metrics of cost-effectiveness, antimicrobial activity, and biocompatibility in vitro, and wound healing in vivo. Methods: To produce the alternative dressing, 3% bismuth tribromophenate powder was combined with petroleum jelly by hand and applied to Kerlix gauze. To assess cost-effectiveness, the unit costs of Xeroform and components of the alternative dressing were compared. To assess antimicrobial properties, the dressings were placed on agar plated with Escherichia coli and the Kirby-Bauer assay performed. To assess biocompatibility, the dressings were incubated with human dermal fibroblasts and cells stained with methylene blue. To assess in vivo wound healing, dressings were applied to excisional wounds on rats and the rate of re-epithelialization calculated. Results: The alternative dressing costs 34% of the least expensive brand of Xeroform. Antimicrobial assays showed that both dressings had similar bacteriostatic effects. Biocompatibility assays showed that there was no statistical difference (P < 0.05) in the cytotoxicity of Xeroform, alternative dressing, and Kerlix gauze. Finally, the in vivo healing model showed no statistical difference (P < 0.05) in mean re-epithelialization time between Xeroform (13.0 ± 1.6 days) and alternative dressing (13.5 ± 1.0 days). Conclusions: Xeroform is biocompatible, reduces infection, and enhances healing of burn wounds by preventing desiccation and mechanical trauma. Handmade petrolatum gauze may be a low-cost replacement for Xeroform. Future studies will focus on clinical trials in burn units. PMID:27482485
Nherera, Leo; Trueman, Paul; Roberts, Christopher; Berg, Leena
2018-02-23
Burn injury is a common type of traumatic injury that causes considerable morbidity and mortality, resulting in about 30,000 admissions annually in specialist burn centers and costing around $1 billion per year in the United States. One percent silver sulfadiazine has been utilized widely in the management of burns and newer silver dressings are on the market, including nanocrystalline silver dressings, silver-impregnated hydrofiber dressings, and silver-impregnated foam dressings. This study sought to determine the cost effectiveness of the newer silver dressings using clinical data from an indirect treatment comparison using silver sulfadiazine as the baseline. A decision analytic model was developed from a US payer's perspective for burn patients with a total body surface area of < 20%. Outcomes were length of stay, infections and incidence of surgical procedures, quality adjusted life years (QALYs), and cost. The meta-analysis reported a statistically significant reduction in length of hospital stay and clinically important reductions in infections and incidence of surgical procedures in favor of the silver barrier dressing compared with other silver dressings. The estimated QALYs were 0.970 versus 0.969 versus 0.969 and mean cost per patient was $15,892, $23,799, and $24,269 for the nanocrystalline silver dressing, silver-impregnated hydrofiber dressing, and silver-impregnated foam dressing, respectively. The analysis showed the nanocrystalline silver dressing to be a dominant strategy (less costly with better outcomes). These findings were robust to a range of sensitivity analyses. According to data from an indirect treatment comparison, this analysis suggests that nanocrystalline silver dressing is the most cost-effective silver delivery system. Prospective head-to-head research on the costs and outcomes of these silver delivery systems in this patient population is necessary to validate the results of this economic evaluation.
Gee Kee, Emma; Kimble, Roy M; Cuttle, Leila; Stockton, Kellie
2013-11-25
In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤ 10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Australian New Zealand Clinical Trials Registry ACTRN12613000105741.
Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain.
Healy, Ciaran; Greig, Aina V H; Murphy, Adrian D; Powell, Christopher; Pinder, Richard J; Saour, Samer; Abela, Christopher; Knight, William; Geh, Jenny L C
2013-07-01
Pain at split skin graft donor sites is common. Fibrin sealant has been demonstrated to reduce time to hemostasis at wound sites, and patients receiving this treatment were incidentally noted to report less pain. This study aimed to evaluate pain and incapacity in split skin graft donor sites treated with and without fibrin sealant. Fifty patients requiring thigh donor-site split skin grafts were prospectively randomized to receive either a self-adhesive fabric dressing alone or fibrin sealant plus the self-adhesive fabric dressing as primary donor-site dressings. External secondary dressings were the same. Patients were blinded with regard to treatment group. Using visual analogue scales (scored 0 to 5), patients rated their donor-site pain and incapacity for 14 days postoperatively. Secondary endpoints were length of hospital stay and duration of requirement for dressings. Forty patients were included in the study analysis and completed self-reported pain and incapacity scores. Twenty received the fibrin sealant plus self-adhesive fabric dressing and 20 received the fabric dressing only (controls). Patients using the fibrin sealant plus the dressing reported significantly less pain (mean score, 0.42 versus 1.60, p < 0.001) and significantly less incapacity (mean score, 0.48 versus 1.71, p < 0.001). Patients allocated to the fibrin sealant group recorded shorter lengths of stay and faster time to discontinuation of dressing, though statistical significance was not achieved. Patients whose split skin graft donor sites were dressed with fibrin sealant plus self-adhesive fabric dressing experienced significantly less pain and incapacity than patients with self-adhesive fabric dressings alone, allowing a more rapid return to normal activity. Therapeutic, II.
Klode, J; Schöttler, L; Stoffels, I; Körber, A; Schadendorf, D; Dissemond, J
2011-08-01
In the process of chronic wound care, adhesive wound dressings may cause pain and injury in the wound environment during dressing changes. At present, no standardized test procedures are available for the investigation of adhesion of wound dressings. Therefore, our study aimed to test the adhesion of different wound dressings on steel as well as on healthy skin. Within an open, comparative study, the adhesive areas of 56 wound dressings were investigated. The adhesives were categorized into acrylate (n = 23), silicone (n = 9), hydrocolloid (n = 17) and polyurethane groups (n = 7). Using an especially modified testing machine, the adhesion of the wound dressings was measured on steel as well as on the skin of healthy study participants, in compliance with the European EN 1939:2003 standard. The energy required to remove the wound dressings from human skin, was measured in Newton (N) and the following median values were obtained: hydrocolloid (2.25 N) > acrylate (1.14 N) > polyurethane (0.9 N) > silicone (0.7 N). The subjective pain intensity during the removal of the wound dressings was recorded using the visual analogue scale (VAS) with values ranging from 0 to 10. For hydrocolloid, it was 6.8, for acrylate 4.9, for polyurethane 3.1 and for silicone 2.5 points VAS. In comparison with human skin, the adhesion of wound dressings was significantly higher on steel (P < 0.0001), but was different for the different groups of wound dressings. Moreover, there was a statistically significant correlation between the adhesion and pain intensity (correlation coefficient 0.806; P = 0.01). The knowledge about the widely differing adhesion properties of different wound dressings on the skin of patients should nowadays be considered during the individual selection of the applied products. Based on these data, different types of wound dressings could be developed, guaranteeing a good adhesion and a low traumatic risk when removed. © 2010 The Authors. Journal of the European Academy of Dermatology and Venereology © 2010 European Academy of Dermatology and Venereology.
Renda, Francesca; Landoni, Giovanni; Bertini Malgarini, Renato; Assisi, Alessandro; Azzolini, Maria Luisa; Mucchetti, Marta; Pimpinella, Giuseppe; Pani, Luca
2015-12-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a rare, severe and potentially fatal cutaneous adverse drug reaction (the mortality rate is up to 10 %) associated with numerous and apparently heterogeneous drugs. The aetiology is unknown. To report Italian cases of DRESS over a 10-year period. We searched the National Pharmacovigilance Network (NPN) for the term 'drug reaction with eosinophilia and systemic symptoms' from 1 January 2004 to 1 January 2014, to identify all reports of DRESS. Each case was checked to avoid duplication. In the NPN, we identified 91 serious cases of DRESS: 68 were spontaneous, still-unpublished reports, while 23 additional cases were derived from screening of the scientific literature, performed by marketing authorization holders. Notably, the single common element linking all cases of DRESS was intake of a drug containing an aromatic ring. Thanks to the largest national DRESS case series ever reported, we were able to hypothesize, for the first time, that there is an association between use of drugs containing an aromatic ring in their chemical structure and DRESS. This might aid understanding of the aetiology of DRESS and facilitate diagnosis.
NASA Astrophysics Data System (ADS)
Wei, Qilin; Xu, Feiyang; Xu, Xingjian; Geng, Xue; Ye, Lin; Zhang, Aiying; Feng, Zengguo
2016-06-01
The non-woven wound dressing with core-shell structured fibers was prepared by coaxial electrospinning. The polycaprolactone (PCL) was electrospun as the fiber's core to provide mechanical strength whereas collagen was fabricated into the shell in order to utilize its good biocompatibility. Simultaneously, the silver nanoparticles (Ag-NPs) as anti-bacterial agent were loaded in the shell whereas the vitamin A palmitate (VA) as healing-promoting drug was encapsulated in the core. Resulting from the fiber's core-shell structure, the VA released from the core and Ag-NPs present in the shell can endow the dressing both heal-promoting and anti-bacteria ability simultaneously, which can greatly enhance the dressing's clinical therapeutic effect. The dressing can maintain high swelling ratio of 190% for 3 d indicating its potential application as wet dressing. Furthermore, the dressing's anti-bacteria ability against Staphylococcus aureus was proved by in vitro anti-bacteria test. The in vitro drug release test showed the sustainable release of VA within 72 h, while the cell attachment showed L929 cells can well attach on the dressing indicating its good biocompatibility. In conclusion, the fabricated nanofibrous dressing possesses multiple functions to benefit wound healing and shows promising potential for clinical application.
Imran, Muhammad; Hussain, Muhammad Barkaat; Baig, Mukhtiar
2015-10-01
To investigate the effect of Beri-honey-impregnated dressing on diabetic foot ulcer and compare it with normal saline dressing. A randomized, controlled trial. Sughra Shafi Medical Complex, Narowal, Pakistan and Bhatti International Trust (BIT) Hospital, Affiliated with Central Park Medical College, Lahore, from February 2006 to February 2010. Patients with Wagner's grade 1 and 2 ulcers were enrolled. Those patients were divided in two groups; group A (n=179) treated with honey dressing and group B (n=169) treated with normal saline dressing. Outcome measures were calculated in terms of proportion of wounds completely healed (primary outcome), wound healing time, and deterioration of wounds. Patients were followed-up for a maximum of 120 days. One hundred and thirty six wounds (75.97%) out of 179 were completely healed with honey dressing and 97 (57.39%) out of 169 wtih saline dressing (p=0.001). The median wound healing time was 18.00 (6 - 120) days (Median with IQR) in group A and 29.00 (7 - 120) days (Median with IQR) in group B (p < 0.001). The present results showed that honey is an effective dressing agent instead of conventional dressings, in treating patients of diabetic foot ulcer.
21 CFR 169.150 - Salad dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...
21 CFR 169.115 - French dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false French dressing. 169.115 Section 169.115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
21 CFR 169.150 - Salad dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Salad dressing. 169.150 Section 169.150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION FOOD DRESSINGS AND FLAVORINGS Requirements for Specific Standardized Food Dressings and Flavorings...
Alternative definition of excitation amplitudes in multi-reference state-specific coupled cluster
NASA Astrophysics Data System (ADS)
Garniron, Yann; Giner, Emmanuel; Malrieu, Jean-Paul; Scemama, Anthony
2017-04-01
A central difficulty of state-specific Multi-Reference Coupled Cluster (MR-CC) in the multi-exponential Jeziorski-Monkhorst formalism concerns the definition of the amplitudes of the single and double excitation operators appearing in the exponential wave operators. If the reference space is a complete active space (CAS), the number of these amplitudes is larger than the number of singly and doubly excited determinants on which one may project the eigenequation, and one must impose additional conditions. The present work first defines a state-specific reference-independent operator T˜ ^ m which acting on the CAS component of the wave function |Ψ0m⟩ maximizes the overlap between (1 +T˜ ^ m ) |Ψ0m⟩ and the eigenvector of the CAS-SD (Singles and Doubles) Configuration Interaction (CI) matrix |ΨCAS-SDm⟩ . This operator may be used to generate approximate coefficients of the triples and quadruples, and a dressing of the CAS-SD CI matrix, according to the intermediate Hamiltonian formalism. The process may be iterated to convergence. As a refinement towards a strict coupled cluster formalism, one may exploit reference-independent amplitudes provided by (1 +T˜ ^ m ) |Ψ0m⟩ to define a reference-dependent operator T^ m by fitting the eigenvector of the (dressed) CAS-SD CI matrix. The two variants, which are internally uncontracted, give rather similar results. The new MR-CC version has been tested on the ground state potential energy curves of 6 molecules (up to triple-bond breaking) and two excited states. The non-parallelism error with respect to the full-CI curves is of the order of 1 mEh.
Hirche, Z; Xiong, L; Hirche, C; Willis, S
2016-04-01
Topical negative pressure therapy (TNPT) has been established for surgical wound therapy with different indications. Nevertheless, there is only sparse evidence regarding its therapeutic superiority or cost-effectiveness in the German DRG system (G-DRG). This study was designed to analyse the cost-effectiveness of TNPT in the G-DRG system with a focus on daily treatment costs and reimbursement in a general surgery care setting. In this retrospective study, we included 176 patients, who underwent TNPT between 2007 and 2011 for general surgery indications. Analysis of the cost-effectiveness involved 149 patients who underwent a simulation to calculate the reimbursement with or without TNPT by a virtual control group in which the TNP procedure was withdrawn for DRG calculation. This was followed by a calculation of costs for wound dressings and TNPT rent and material costs. Comparison between the "true" and the virtual group enabled calculation of the effective remaining surplus per case. Total reimbursement by included TNPT cases was 2,323 ,70.04 €. Costs for wound dressings and TNPT rent were 102,669.20 €. In 41 cases there was a cost-effectiveness (27.5%) with 607,422.03 € with TNP treatment, while the control group without TNP generated revenues of 442,015.10 €. Costs for wound dressings and TNPT rent were 47,376.68 €. In the final account we could generate a cost-effectiveness of 6759 € in 5 years per 149 patients by TNPT. In 108 cases there was no cost-effectiveness (72.5%). TNPT applied in a representative general surgery setting allows for wound therapy without a major financial burden. Based on the costs for wound dressings and TNPT rent, a primarily medically based decision when to use TNPT can be performed in a balanced product cost accounting. This study does not analyse the superiority of TNPT in wound care, so further prospective studies are required which focus on therapeutic superiority and cost-effectiveness. Georg Thieme Verlag KG Stuttgart · New York.
ERIC Educational Resources Information Center
Dulin, Charles Dewitt
2016-01-01
The purpose of this research is to evaluate the impact of uniform dress codes on a school's climate for student behavior and learning in four middle schools in North Carolina. The research will compare the perceptions of parents, teachers, and administrators in schools with uniform dress codes against schools without uniform dress codes. This…
Verbelen, Jozef; Hoeksema, Henk; Heyneman, Alexander; Pirayesh, Ali; Monstrey, Stan
2014-05-01
Studies comparing contemporary silver dressings in burns are scarce. In a prospective, randomized, controlled study, counting 50 patients/research group, we compared two frequently used silver dressings, Acticoat™ and Aquacel(®) Ag, in the management of partial thickness burns with a predicted healing time between 7 and 21 days as assessed by laser Doppler imaging between 48 and 72h after burn. Variables investigated were related to baseline research group characteristics, wound healing, bacteriology, economics, nurse, and patient experience. Both research groups were comparably composed taking into account gender, age and burn characteristics. Similar results were obtained as to healing time and bacterial control with both silver dressings. A statistically significant difference in favor of the Aquacel(®) Ag dressing was found for average ease of use (p<0.001), average ease of application (p=0.001), patient pain (p<0.001), patient comfort with the dressing (p=0.017), silver staining (p<0.001), and cost effectiveness (p<0.001). Both silver dressings resulted in comparable healing times and bacterial control but the Aquacel(®) Ag dressing significantly increased comfort for patients as well as nurses and was significantly more cost-effective than the Acticoat™ dressing for the given indication. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Payne, Wyatt G; Posnett, John; Alvarez, Oscar; Brown-Etris, Marie; Jameson, Gayle; Wolcott, Randall; Dharma, Hussein; Hartwell, Samantha; Ochs, Diane
2009-02-01
Modern dressings such as hydrocolloids, gels, and foams are typically more expensive than traditional dressings such as gauze. However, if modern dressings require fewer changes, the overall cost of treatment may be lower despite the higher initial purchase price. If healing rates are comparable or better, modern dressings also may be cost-effective. A 4-week, prospective, randomized clinical trial to assess differences in treatment costs and cost-effectiveness between a modern foam dressing and saline-soaked gauze was conducted among 36 patients (22 men, 14 women, mean age 72.8 years) with a Stage II pressure ulcer (mean duration 35 weeks) at five centers in the United States. Participants were randomized to treatment with a self-adhesive polyurethane foam (n = 20) or saline-soaked gauze dressing (n = 16). No difference in time to wound closure was observed (P = 0.817). Patients in the foam group had less frequent dressing changes (P <0.001). Total cost over the study period was lower by $466 per patient (P = 0.055) and spending on dressings was lower by $92 per patient in the foam group (P = 0.025). Cost per ulcer healed was lower by $1,517 and cost per ulcer-free day was lower by $80 for patients in the foam group. On the evidence of this study, the foam dressing is a more cost-effective treatment than saline-soaked gauze for the treatment of Stage II pressure ulcers.
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic wound dressing. 878.4018 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing. (a) Identification. A hydrophilic wound dressing is a sterile or non-sterile device intended to cover...
Rationale for Student Dress Codes: A Review of School Handbooks
ERIC Educational Resources Information Center
Freeburg, Elizabeth W.; Workman, Jane E.; Lentz-Hees, Elizabeth S.
2004-01-01
Through dress codes, schools establish rules governing student appearance. This study examined stated rationales for dress and appearance codes in secondary school handbooks; 182 handbooks were received. Of 150 handbooks containing a rationale, 117 related dress and appearance regulations to students' right to a non-disruptive educational…
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrogel wound dressing and burn dressing. 878.4022 Section 878.4022 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4022...
Colloidal silver-based nanogel as nonocclusive dressing for multiple superficial pellet wounds.
Dharmshaktu, Ganesh Singh; Singhal, Aanshu; Pangtey, Tanuja
2016-01-01
A good dressing is mandatory to an uncomplicated wound healing, especially when foreign particles contaminate the wound. Various forms of dressing preparations are available for use and differ in chemical composition and efficacy. Silver has been a known agent with good antimicrobial and healing properties and recent times has seen an upsurge in various silver-based dressing supplements. We describe our report of use and efficacy of a silver nanoparticle- based gel dressing in the healing of multiple superficial firearm pellet wounds.
Self adhesive dressing pouch for the protection of catheters.
de la Cruz Martínez, Maria Teresa; Hernández, María José
2002-01-01
This paper is about a new model of dressing, used for the protection of all types of temporary and permanent catheters. Those who developed this dressing realised the practical difficulties during the placement and removal of traditional dressings, used in haemodialysis units. They also realised that it this was unpleasant for the patients, and there was a risk to the catheters when removing the dressings because of the use of scissors and other cutting instruments. This new dressing solves these previously mentioned problems and at the same time contributes to the comfort of the patients. The model has been registered as a standard using model, and therefore it is protected by law and its copyright (Intellectual Property).
Tunable electromagnetically induced transparency and absorption with dressed superconducting qubits
NASA Astrophysics Data System (ADS)
Ian, Hou; Liu, Yu-Xi; Nori, Franco
2010-06-01
Electromagnetically induced transparency and absorption (EIT and EIA) are usually demonstrated using three-level atomic systems. In contrast to the usual case, we theoretically study the EIT and EIA in an equivalent three-level system: a superconducting two-level system (qubit) dressed by a single-mode cavity field. In this equivalent system, we find that both the EIT and the EIA can be tuned by controlling the level-spacing of the superconducting qubit and hence controlling the dressed system. This tunability is due to the dressed relaxation and dephasing rates which vary parametrically with the level-spacing of the original qubit and thus affect the transition properties of the dressed qubit and the susceptibility. These dressed relaxation and dephasing rates characterize the reaction of the dressed qubit to an incident probe field. Using recent experimental data on superconducting qubits (charge, phase, and flux qubits) to demonstrate our approach, we show the possibility of experimentally realizing this proposal.
Childress, Beverly B; Berceli, Scott A; Nelson, Peter R; Lee, W Anthony; Ozaki, C Keith
2007-09-01
Surgical wounds for lower extremity revascularization are prone to infection and dehiscence. Acticoat Absorbent, an antimicrobial dressing, offers sustained release of ionic silver. We hypothesized that immediate application of Acticoat as a postoperative dressing would reduce wound complications in patients undergoing leg revascularization. All infrainguinal revascularization cases involving leg incisions at a single Veterans Administration Medical Center were identified from July 1, 2002, to September 30, 2005. The control group received conventional dressings, while the treatment group received an Acticoat dressing. Wound complication rates were captured via National Surgical Quality Improvement Program data. Patient characteristics and procedure distributions were similar between groups. The wound complication rate fell 64% with utilization of the Acticoat-based dressing (control 14% [17/118], treatment 5% [7/130]; P = 0.016). An Acticoat-based dressing system offers a potentially useful, cost-effective adjunct to reduce open surgical leg revascularization wound complications.
School Dress Codes v. The First Amendment: Ganging up on Student Attire.
ERIC Educational Resources Information Center
Jahn, Karon L.
Do school dress codes written with the specific purpose of limiting individual dress preferences, including dress associated with gangs, infringe on speech freedoms granted by the First Amendment of the U.S. Constitution? Although the Supreme Court has extended its protection of political speech to nonverbal acts of communication, it has…
Dressing of Cognitively Impaired Nursing Home Residents: Description and Analysis
ERIC Educational Resources Information Center
Cohen-Mansfield, Jiska; Creedon, Michael A.; Malone, Thomas; Parpura-Gill, Aleksandra; Dakheel-Ali, Maha; Heasly, Christopher
2006-01-01
Purpose: Getting dressed is an activity that is of particular difficulty for many persons with dementia, given the need for hand-eye coordination, fine motor skills, and overall planning skills. Despite several studies concerning interventions to improve dressing behavior, very little is known about the dressing process as it is currently…
Women in relationships with cross-dressing men: a descriptive study from a nonclinical setting.
Brown, G R
1994-10-01
Over a 6-year period, 106 women involved with men who cross-dress (mostly heterosexual transvestites) completed a questionnaire regarding themselves, their male partners, and their relationships. Interview data supplemented these questionnaires for 75% of the respondents. All respondents were recruited from nonclinical settings. The "modal" female partner was a 40-year-old Protestant, Caucasian woman, who was a firstborn child, in her first marriage. She was more likely than other women her age to be childless, and to have earned at least a 2-year college degree. She was no more likely to have had lesbian experiences or substance use problems than comparably aged American women. She had been married to her cross-dressing mate for 13 years and had known of his activities for 9 years. A quarter of women reported at least occasional sexual arousal to their mate's cross-dressing. The two variables associated with low acceptance of cross-dressing were discovery of their partner's cross-dressing after marriage and lack of sexual arousal to cross-dressing stimuli. Low acceptance was unrelated to firstborn status, amount of exposure to cross-dressing activities, or having had children. This group may be more representative of women in relationships with cross-dressing men than previous reports limited to cross-dressers and spouses who are in treatment.
Umbilical Negative Pressure Dressing for Transumbilical Appendectomy in Childern.
Seifarth, Federico G; Kundu, Neilendu; Guerron, Alfredo D; Garland, Mary M; Gaffley, Michaela W G; Worley, Sarah; Knight, Colin G
2016-01-01
Transumbilical laparoscopic-assisted appendectomy (TULAA) carries a high risk for surgical site infection. We investigated the effect of a bio-occlusive umbilical vacuum dressing on wound infection rates after TULAA for patients with acute appendicitis and compared to it with a conventional 3-port appendectomy with a nonvacuum dressing. This study was a retrospective chart review of 1377 patients (2-20 years) undergoing laparoscopic appendectomy for acute appendicitis in 2 tertiary care referral centers from January 2007 through December 2012. Twenty-two different operative technique/dressing variations were documented. The 6 technique/dressing groups with >50 patients were assessed, including a total of 1283 patients. The surgical site infection rate of the 220 patients treated with TULAA and application of an umbilical vacuum dressing with dry gauze is 1.8% (95% CI, 0.0-10.3%). This compares to an infection rate of 4.1% (95% CI, 1.3-10.5%) in 97 patients with dry dressing without vacuum. In the 395 patients who received an umbilical vacuum dressing with gauze and bacitracin, the surgical site infection rate was found to be 4.3% (95% CI, 2.7-6.8%). Application of an umbilical negative-pressure dressing with dry gauze lowers the rate of umbilical site infections in patients undergoing transumbilical laparoscopic-assisted appendectomy for acute appendicitis.
Human neutrophil elastase and collagenase sequestration with phosphorylated cotton wound dressings.
Edwards, J Vincent; Howley, Phyllis S
2007-11-01
The design and preparation of wound dressings that redress the protease imbalance in chronic wounds is an important goal of wound healing and medical materials science. Chronic wounds contain high levels of tissue and cytokine-destroying proteases including matrix metalloprotease and neutrophil elastase. Thus, the lowering of excessive protease levels in the wound environment by wound dressing sequestration prevents the breakdown of extracellular matrix proteins and growth factors necessary for wound healing. Phosphorylated cotton wound dressings were prepared to target sequestration of proteases from chronic wound exudate through a cationic uptake binding mechanism involving salt bridge formation of the positively charged amino acid side chains of proteases with the phosphate counterions of the wound dressing fiber. Dressings were prepared by applying sodium hexametaphosphate and diammonium phosphate in separate formulations to cotton gauze by pad/dry/cure methods. Phosphorylated cotton dressings were assessed for their ability to lower elastase and collagenase activity. The phosphorylated cotton dressings lowered elastase and collagenase activity 40-80% more effectively than the untreated cotton wound dressings under conditions that mimic chronic wound exudate. Efficacy of the phosphorylated cotton was found to be related to the level of phosphorylation and a lower pH due to protonated phosphate at the surface of the dressing. The capacity of the modified gauze to sequester continued elastase secretions similar to that found in a chronic wound over a 24-h period was retained within a 80% retention of elastase sequestration and was dose-dependent. Copyright (c) 2007 Wiley Periodicals, Inc.
Analysis of the Pressure Distribution Qualities of a Silicone Border Foam Dressing.
Miller, Stephannie K; Sharma, Neal; Aberegg, Lauren C; Blasiole, Kimberly N; Fulton, Judith A
2015-01-01
To determine whether application of a silicone foam dressing is associated with decreased interface pressures when applied to the heel. Prospective, within-subjects design. The study was conducted in a community-based hospital using a convenience sample of 50 healthy volunteers with a mean age of 39.6 years and mean body mass index of 26.6; 70% were female. Application of the silicone border foam dressing was randomized between the left and right heels. Participants were asked to lie down in the supine position on a viscoelastic foam mattress. Interface pressure measurements were captured using a pressure mapping system; measurements were taken once with the dressing applied to the heel (intervention map) and once without (control map). Data were captured after a 4-minute time period allowing stabilization. Analysis was based on mean interface pressure; data points were collected for both heels in each of the 2 frames, yielding 4 observations per subject. Application of the dressing was associated with a significant decrease in average pressure measurements as compared to the heel with no dressing applied (P < .001). Application of the dressing did not impact pressure readings for the heel to which no dressing was applied (P = .53), and application of the dressing to either the left or right heel did not impact pressure readings (ie, the random effect was insignificant; P = .9). Application of a silicone border foam dressing is associated with significant reduction in interface pressure and may be considered as part of a pressure ulcer prevention program.
Enhanced wound contraction in fresh wounds dressed with honey in Wistar rats (Rattus Novergicus).
Osuagwu, F C; Oladejo, O W; Imosemi, I O; Aiku, A; Ekpos, O E; Salami, A A; Oyedele, O O; Akang, E U
2004-01-01
Due to reports that honey accelerates wound healing, an investigation on its role in wound contraction in fresh wounds inflicted on wistar rats was carried out. Twenty adult male wistar rats had 2cm by 2cm square wound inflicted on their right dorsolateral trunk. They were divided into two groups. The experimental group had their wounds dressed with honey while the control group had normal saline dressing. Wound dressing was done every five days and measurements taken at each dressing. Wound morphology was also assessed. Dressing with honey significantly enhanced percentage wound contraction on day 10 with value of 79.20+/-2.94 compared to control value of 53.50+/-4.32. p=0.0. The mean wound measurement on day 10 reduced significantly in honey group, 1.15+/-0.18 compared to control group 2.38+/-0.28. p=0.002. However, there was no significant difference in fibroblast count per high power field in honey group 68.0+/-2.59 compared to control 90.2+/-17.40, p=0.242. Honey dressing increased mean blood vessel count per high power field, 18.8+/-3.77 albeit non significantly when compared to control value of 13.4+/-2.44, p=0.264. Also honey dressing caused increased granulation tissue formation in wounds dressed with honey compared to control group. Our study suggests that honey dressing enhances wound contraction in fresh wounds which is one of the key features of wound healing.
Processing parameter optimization for the laser dressing of bronze-bonded diamond wheels
NASA Astrophysics Data System (ADS)
Deng, H.; Chen, G. Y.; Zhou, C.; Li, S. C.; Zhang, M. J.
2014-01-01
In this paper, a pulsed fiber-laser dressing method for bronze-bonded diamond wheels was studied systematically and comprehensively. The mechanisms for the laser dressing of bronze-bonded diamond wheels were theoretically analyzed, and the key processing parameters that determine the results of laser dressing, including the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles, were proposed for the first time. Further, the effects of these four key parameters on the oxidation-damaged layer of the material surface, the material removal efficiency, the material surface roughness, and the average protrusion height of the diamond grains were explored and summarized through pulsed laser ablation experiments. Under the current experimental conditions, the ideal values of the laser power density, pulse overlap ratio, ablation track line overlap ratio, and number of scanning cycles were determined to be 4.2 × 107 W/cm2, 30%, 30%, and 16, respectively. Pulsed laser dressing experiments were conducted on bronze-bonded diamond wheels using the optimized processing parameters; next, both the normal and tangential grinding forces produced by the dressed grinding wheel were measured while grinding alumina ceramic materials. The results revealed that the normal and tangential grinding forces produced by the laser-dressed grinding wheel during grinding were smaller than those of grinding wheels dressed using the conventional mechanical method, indicating that the pulsed laser dressing technology provides irreplaceable advantages relative to the conventional mechanical dressing method.
NASA Astrophysics Data System (ADS)
Gauthey, F. I.; Keitel, C. H.; Knight, P. L.; Maquet, A.
1995-07-01
We investigate the coherent and incoherent contributions of the scattering spectrum of strongly driven two-level atoms as a function of the initial preparation of the atomic system. The initial ``phasing'' of the coherent superposition of the excited and ground states is shown to influence strongly the generation of both harmonics and hyper-Raman lines. In particular, we point out conditions under which harmonic generation can be inhibited at the expense of the hyper-Raman lines. Our numerical findings are supported by approximate analytical evaluation in the dressed state picture.
Siritientong, Tippawan; Angspatt, Apichai; Ratanavaraporn, Juthamas; Aramwit, Pornanong
2014-01-01
An ethyl alcohol-precipitated silk sericin/PVA scaffold that controlled the release of silk sericin was previously developed and applied for the treatment of full-thickness wounds in rats and demonstrated efficient healing. In this study, we aimed to further evaluate the clinical potential of this scaffold, hereafter called "silk sericin-releasing wound dressing", for the treatment of split-thickness skin graft donor sites by comparison with the clinically available wound dressing known as "Bactigras®". In vitro characterization and in vivo evaluation for safety of the wound dressings were performed. A clinical trial of the wound dressings was conducted according to standard protocols. The sericin released from the wound dressing was not toxic to HaCat human keratinocytes. A peel test indicated that the silk sericin-releasing wound dressing was less adhesive than Bactigras®, potentially reducing trauma and the risk of repeated injury upon removal. There was no evidence of skin irritation upon treatment with either wound dressing. When tested in patients with split-thickness skin graft donor sites, the wounds treated with the silk sericin-releasing wound dressing exhibited complete healing at 12 ± 5.0 days, whereas those treated with Bactigras® were completely healed at 14 ± 5.2 days (p = 1.99 × 10(-4)). In addition, treatment with the silk sericin-releasing wound dressing significantly reduced pain compared with Bactigras® particularly during the first 4 postoperative days (p = 2.70 × 10(-5) on day 1). We introduce this novel silk sericin-releasing wound dressing as an alternative treatment for split-thickness skin graft donor sites.
A model for quantitative evaluation of skin damage at adhesive wound dressing removal.
Matsumura, Hajime; Ahmatjan, Niyaz; Ida, Yukiko; Imai, Ryutaro; Wanatabe, Katsueki
2013-06-01
The removal of adhesive wound dressings from the wound surface involves a risk of damaging the intact stratum corneum and regenerating epithelium. Pain associated with the removal of wound dressings is a major issue for patients and medical personnel. Recently, wound dressings coated with a silicone adhesive have been developed to reduce such skin damage and pain on removal and they have received good evaluation in various clinical settings. However, there is neither a standard method to quantify whether or not the integrity of the stratum corneum and regenerating epithelium is retained or if both structures are damaged by the removal of wound dressings, nor are there standardised values with which to assess skin damage. We applied six different types of adhesive wound dressing on plain copy paper printed with black ink by a laser printer, removed the dressings, examined the adhesive-coated surface of the wound dressings using a high-power videoscope, and examined the stripped areas. Wound dressings coated with a silicone adhesive showed significantly less detachment of the stratum corneum and regenerating epithelium, followed by those coated with polyurethane, hydrocolloid, and acrylic adhesives. The assessment method utilised in this study revealed distinct differences between wound dressing types, but less variation in the evaluation outcome of each type. This assessment method may be useful for the evaluation of adhesive wound dressings, particularly during product development. However, further studies will be needed to examine the effectiveness of this assessment method in the clinical setting because the adherent properties of polyurethane and hydrocolloid adhesives may be altered by the absorption of water from the skin. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.
Effect of different wound dressings on cell viability and proliferation.
Paddle-Ledinek, Joanne E; Nasa, Zeyad; Cleland, Heather J
2006-06-01
Many new dressings have been developed since the early 1980s. Wound healing comprises cleansing, granulation/vascularization, and epithelialization phases. An optimum microenvironment and the absence of cytotoxic factors are essential for epithelialization. This study examines the effect of extracts of different wound dressings on keratinocyte survival and proliferation. Keratinocyte cultures were exposed for 40 hours to at least three extracts of each of the following wound dressings, which were tested in octuplicate: Acticoat, Aquacel-Ag, Aquacel, Algisite M, Avance, Comfeel Plus transparent, Contreet-H, Hydrasorb, and SeaSorb. Silicone extract provided the reference material. Controls were included of cells cultured in medium that had been incubated under conditions identical to those used with the extracts. Cell survival (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide reduction) and proliferation (5-bromo-2':-deoxyuridine incorporation) were measured. Extracts of silver-containing dressings (Acticoat, Aquacel-Ag, Contreet-H, and Avance) were most cytotoxic. Extracts of Hydrasorb were less cytotoxic but markedly affected keratinocyte proliferation and morphology. Extracts of alginate-containing dressings (Algisite M, SeaSorb, and Contreet-H) demonstrated high calcium concentrations, markedly reduced keratinocyte proliferation, and affected keratinocyte morphology. Extracts of Aquacel and Comfeel Plus transparent induced small but significant inhibition of keratinocyte proliferation. The principle of minimizing harm should be applied to the choice of wound dressing. Silver-based dressings are cytotoxic and should not be used in the absence of infection. Alginate dressings with high calcium content affect keratinocyte proliferation probably by triggering terminal differentiation of keratinocytes. Such dressings should be used with caution in cases in which keratinocyte proliferation is essential. All dressings should be tested in vitro before clinical application.
Role of natural polysaccharides in radiation formation of PVA hydrogel wound dressing
NASA Astrophysics Data System (ADS)
Varshney, Lalit
2007-02-01
Radiation processed PVA-polysaccharides hydrogels have been observed to be suitable for producing transparent, flexible, mechanically strong, biocompatible, effective and economical hydrogel dressings. The dressings were formed in single stage irradiation process achieving gel formation and sterilization at 25-30 kGy gamma radiation dose. No synthetic plasticizers and additives were used. Different formulations containing poly-vinylalcohol (PVA) and polysaccharides selected from combinations of agar and carrageenan were used to make the dressings. The selected polysaccharides themselves form thermo-reversible gels and degrade on irradiation. Using concentration of polysaccharides as low as 0.5-2% resulted in increase of tensile strength from 45 g/cm 2 to 411 g/cm 2, elongation from 30% to 410% and water uptake from 25% to 157% with respect to PVA gel without polysaccharides. Besides improving mechanical strength, agar contributes more to elongation and carrageenan to mechanical strength of the gel dressing. PVA formulations containing the polysaccharides show significantly different pre-gel viscosities behaviour. Increasing the concentration of agar in the formulation to about 2% converts the sheet gel to paste gel useful for filling wound cavities. The results indicate that pre irradiation network structure of the formulation plays an important role in determining mechanical properties of the irradiated gel dressing. Formulations containing 7-9% PVA, 0.5-1.5% carrageenan and 0.5-1% agar gave highly effective usable hydrogel dressings. Scanning electron micrographs show highly porous structure of the gel. Clinical trials of wound dressing on human patients established safety and efficacy of the dressing. The dressing has been observed to be useful in treating burns, non-healing ulcers of diabetes, leprosy and other external wounds. The dressings are now being marketed in India under different brand names.
Kleidon, Tricia M; Ullman, Amanda J; Gibson, Victoria; Chaseling, Brett; Schoutrop, Jason; Mihala, Gabor; Rickard, Claire M
2017-11-01
To evaluate feasibility of an efficacy trial comparing peripherally inserted central catheter (PICC) dressing and securement techniques to prevent complications and failure. This pilot, 3-armed, randomized controlled trial was undertaken at Royal Children's Hospital and Lady Cilento Children's Hospital, Brisbane, Australia, between April 2014 and September 2015. Pediatric participants (N = 101; age range, 0-18 y) were assigned to standard care (bordered polyurethane [BPU] dressing, sutureless securement device), tissue adhesive (TA) (plus BPU dressing), or integrated securement dressings (ISDs). Average PICC dwell time was 8.1 days (range, 0.2-27.7 d). Primary outcome was trial feasibility including PICC failure. Secondary outcomes were PICC complications, dressing performance, and parent and staff satisfaction. Protocol feasibility was established. PICC failure was 6% (2/32) with standard care, 6% (2/31) with ISD, and 3% (1/32) with TA. PICC complications were 16% across all groups. TA provided immediate postoperative hemostasis, prolonging the first dressing change until 5.5 days compared with 3.5 days and 2.5 days with standard care and ISD respectively. Bleeding was the most common reason for first dressing change: standard care (n = 18; 75%), ISD (n = 11; 69%), TA (n = 4; 27%). Parental satisfaction (median 9.7/10; P = .006) and staff feedback (9.2/10; P = .002) were most positive for ISD. This research suggests safety and acceptability of different securement dressings compared with standard care; securement dressings may also reduce dressing changes after insertion. Further research is required to confirm clinically cost-effective methods to prevent PICC failure. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
2013-01-01
Background In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Methods/Design Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. Discussion The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12613000105741 PMID:24274190
Choi, Young Suk; Gwak, Heui-Chul; Park, Jae Keun; Lim, Ji Yun; Yeo, Eui Dong; Park, Eunseok; Kim, Junyong; Lee, Young Koo
2018-04-13
Silver nanoparticle (AgNP)-containing dressings are used worldwide for the treatment of wounds; however, many studies have indicated that AgNPs are toxic to humans and cause cell death, primarily via apoptosis. In this study, the investigators compare the apoptotic effects of various AgNP dressing materials, with the hypothesis that nanosilver would be less toxic than ionic silver. For the in vivo experiments, Sprague-Dawley (SD) and streptozotocin (STZ)-induced diabetic rats were treated with 5 dressing materials: Aquacel Ag (product A, silver ion; ConvaTec, Berkshire, UK), Acticoat (product B, AgNP; Smith & Nephew, Fort Worth, TX), Medifoam Silver (product C, silver ion; Genewel Science Co Ltd, Seongnam, South Korea), PolyMem Silver (product D, AgNP; Ferris Mfg Corp, Fort Worth, TX), and Vaseline-impregnated dressing gauze (control; Unilever, London, UK). All treatments were applied 3 times per week. After 14 days of treatment, the SD and STZ rats were euthanized, and wound samples were examined for apoptosis. The analysis included immunohistochemistry, terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining, Western blotting, and reverse transcription polymerase chain reaction for a semiquantitative evaluation of apoptosis. The AgNP-containing dressing materials were more cytotoxic than the silver dressings. Compared with the AgNP dressing materials, no significant levels of apoptotic factors were observed in the silver dressing-treated wounds. The TUNEL staining showed that product C-dressed wounds contained the most apoptotic cells, while some apoptotic cells were observed in product B-dressed wounds. Moreover, apoptotic gene expression was altered, including a decline in B-cell lymphoma-2 and activation of caspase-3. This was most evident in wounds treated with product C. Interestingly, apoptotic gene expression was not induced in product A-treated wounds. Finally, product D had a relatively lower silver concentration and was less toxic than products A-C. Dressing materials containing AgNP have an antimicrobial effect. However, the authors observed that some AgNP dressings induced DNA damage and apoptosis. Although AgNP dressings did not cause significant acute apoptotic effects, they should be examined for cytotoxic effects in chronic wounds and should be used with caution when treating chronic wounds and those with low bacteria counts.
School Dress Codes and Uniform Policies.
ERIC Educational Resources Information Center
Anderson, Wendell
2002-01-01
Opinions abound on what students should wear to class. Some see student dress as a safety issue; others see it as a student-rights issue. The issue of dress codes and uniform policies has been tackled in the classroom, the boardroom, and the courtroom. This Policy Report examines the whole fabric of the debate on dress codes and uniform policies…
Overview of Silk Fibroin Use in Wound Dressings.
Farokhi, Mehdi; Mottaghitalab, Fatemeh; Fatahi, Yousef; Khademhosseini, Ali; Kaplan, David L
2018-05-12
Recently, biomimetic wound dressings were introduced as potential replacements for treating skin injuries. Although there are some clinically available skin replacements, the range of wound types and locations necessitates a broader range of options for the clinic. Natural polymeric-based dressings are of central interest in this area due to their outstanding biocompatibility, biodegradability, low toxicity, and non-allergenic nature. Among them, silk fibroin (SF) has exceptional characteristics as a wound dressing. SF-based dressings can also be used as carriers for delivering drugs, growth factors, and bioactive agents to the wound area, while providing appropriate support for complete healing. In this review, we describe recent advances in the development of SF-based wound dressings for skin regeneration. Copyright © 2018 Elsevier Ltd. All rights reserved.
Small Molecules and Sum Frequency Generation Probes of Nanoparticulate TiO2
NASA Astrophysics Data System (ADS)
Shultz, Mary Jane
2006-03-01
Anatase TiO2 is known to photo catalytically mineralize a wide variety of pollutants and pathogens, both airborne and in aqueous solution. One of the major benefits of basing water treatment systems on TiO2 is that it is environmentally benign and so non toxic that it is used as a colorant in creamy salad dressing. The primary impediment to wide spread implementation of a TiO2 based system for water decontamination is that the quantum efficiency in contact with condense phase water is less than 5%. Since the quantum efficiency for destruction of airborne materials is greater than 80%, the potential for increased efficiency is very real. To convert the potential to practice, the oxidation mechanism needs to be more fully understood. We will report on the results of using a nonlinear optical spectroscopy, sum frequency generation (SFG) as an in situ probe of interactions at the TiO2 surface. Results suggest that the dominant oxidation mechanism converts from a direct to an indirect mechanism as the water content (vapor pressure) increases. This presentation will discuss the probe technique as well as the results.
Yang, Chaochao; Xue, Rui; Zhang, Qingsong; Yang, Shulin; Liu, Pengfei; Chen, Li; Wang, Ke; Zhang, Xiaoyong; Wei, Yen
2017-12-01
High antibacterial and skin-like hydrogels have always been the perfect wound dressing for human to protect wound from infection. Here, based on silk sericin, we design a series of nanoclay lithium magnesium silicate hydrate (LMSH) cross-linked semi-IPN sericin/poly(NIPAm/LMSH) (HSP) nanocomposite hydrogels and demonstrate advantages in serving as antibacterial wound dressing in comparison with gauze. Firstly, the effect of mass ratios of sericin/(sericin+NIPAm) upon pore structure, feasibility of mechanics and gas permeability of HSP nanocomposite hydrogels were evaluated. Then, the relationship between nanocomposite hydrogel and histological/antimicrobial properties was systematically analyzed. It was found that, the introduction of sericin increased internal pore size, leading to obvious transition from honeycomb to layered structure. Furthermore, as mass ratio of sericin/(sericin+NIPAm) is 20%, the wound healing area treated with nanocomposite hydrogels at 6th day reached up to 83%, 3 times of gauze, and almost recovered at 13th day. Especially, antibacterial mechanism can be thought to be the results that the macromolecular sericin embedded in the nanocomposite hydrogel adsorbed bacteria by charge interaction and micromolecular sericin dissociating out from nanocomposite hydrogels can be adsorbed onto bacteria. Copyright © 2017 Elsevier B.V. All rights reserved.
A retrospective review of burn dressings on a porcine burn model.
Wang, Xue-Qing; Kravchuk, Olena; Kimble, Roy M
2010-08-01
This is a study to compare wound healing among three types of dressings on a porcine model with deep-dermal-partial-thickness burns. The burns in this study were from eight animal trials conducted in the past for other purposes and only burns with a uniform pale appearance that had served as controls in original experiments were selected. In total, there were 57 burns in 33 pigs, using one of following three dressings: Acticoat (Silver) (3 trials), Jelonet (Gauze) (3 trials), and Solosite Gel/Jelonet (Gel/Gauze) (2 trials). The wound healing assessments included wound re-epithelialisation during a 6-week period, clinical and histological scar assessments at week 6 after burn. Of all wound healing/scar assessments, only re-epithelialisation showed statistical difference between dressings. Earlier re-epithelialisation was observed in Gel/Gauze dressings compared to Silver and/or Gauze dressings. However, this study revealed huge variation in wound healing outcome between 3 trials within both Silver and/or Gauze dressings, supported by significant differences on re-epithelialisation, clinical and histological scar measurements. In addition, it was found that larger animals healed better than smaller ones, based on weights from 21 pigs. Of all dressings, Silver delivers the best protection for wound colonization/infection. Wound colonization/infection was found to confine wound healing and lead to thinner RND in scars. From this study, we cannot find enough evidence to suggest the beneficial effect of one dressing(s) over others on burn wound healing outcome on a porcine model with small deep-dermal-partial-thickness burns with a relative small sample size.
Guo, Chunlan; Deng, Hongyan; Yang, Jian
2015-01-01
To assess the effect of virtual reality distraction on pain among patients with a hand injury undergoing a dressing change. Virtual reality distraction can effectively alleviate pain among patients undergoing a dressing change. Clinical research has not addressed pain control during a dressing change. A randomised controlled trial was performed. In the first dressing change sequence, 98 patients were randomly divided into an experimental group and a control group, with 49 cases in each group. Pain levels were compared between the two groups before and after the dressing change using a visual analog scale. The sense of involvement in virtual environments was measured using the Pearson correlation coefficient analysis, which determined the relationship between the sense of involvement and pain level. The difference in visual analog scale scores between the two groups before the dressing change was not statistically significant (t = 0·196, p > 0·05), but the scores became statistically significant after the dressing change (t = -30·792, p < 0·01). The correlation between the sense of involvement in a virtual environment and pain level during the dressing was statistically significant (R(2) = 0·5538, p < 0·05). Virtual reality distraction can effectively alleviate pain among patients with a hand injury undergoing a dressing change. Better results can be obtained by increasing the sense of involvement in a virtual environment. Virtual reality distraction can effectively relieve pain without side effects and is not reliant on a doctor's prescription. This tool is convenient for nurses to use, especially when analgesics are unavailable. © 2014 John Wiley & Sons Ltd.
Kelleher, Maureen E; Kilcoyne, Isabelle; Dechant, Julie E; Hummer, Emma; Kass, Philip H; Snyder, Jack R
2015-04-01
To determine if application of silver sodium zirconium phosphate polyurethane semi-occlusive foam (SPF) dressing would improve measures of wound healing and decrease bacterial contamination compared with a non-adherent, absorbent dressing applied to wounds created on the distal aspect of the equine limb. Controlled randomized experimental study. Adult Quarter Horse and Thoroughbred horses (n = 5). One 6.25 cm(2) wound was created on the dorsomedial aspect of the proximal metacarpus on each forelimb. A SPF dressing was applied to 1 randomly assigned limb as a treatment and a non-adherent, absorbent dressing was applied to the opposite limb as control. Bandages were changed every 3 days for 60 days. Granulation tissue was scored every 3 days, wound area measured every 6 days, and wound bed was cultured every 12 days. SPF-treatment wounds had significantly decreased wound area and decreased granulation tissue scores when evaluated <30 days and over the 60 day study, although complete wound healing times were not significantly different. Bacteria were cultured from all wounds at varying times throughout the study. The SPF wound dressing improved some measures of wound healing compared with the control dressing, most significantly during the first 30 days. This suggests that the SPF wound dressing may be useful in the early management of wounds on the equine lower limb. Further studies using the SPF dressing are needed to characterize the temporal and cellular effects on wound healing and evaluate this dressing in a clinical environment. © Copyright 2014 by The American College of Veterinary Surgeons.
Elsner, J J; Berdicevsky, I; Zilberman, M
2011-01-01
About 70% of all people with severe burns die from related infections, despite advances in treatment regimens and the best efforts of nurses and doctors. Although silver-eluting wound dressings are available for addressing this problem, there is growing evidence of the deleterious effects of such dressings in delaying the healing process owing to cellular toxicity. A new concept of antibiotic-eluting composite wound dressings is described here. These dressings are based on a polyglyconate mesh coated with a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with antibiotic drugs. The effect of antibiotic release on bacterial inhibition was studied, and cell cytotoxicity was examined. The dressings resulted in a 99.99% decrease in the viable counts of Pseudomonas aeruginosa and Staphylococcus albus at very high initial inoculations of 10⁷-10⁸ CFU ml⁻¹ after only 1 day, while such a decrease in Staphylococcus aureus was obtained within 3 days. Bacterial inhibition zones around the dressing material were found to persist for 2 weeks, indicating a long-lasting antimicrobial effect. Despite severe toxicity to bacteria, the dressing material was found to have no toxic effect on cultured fibroblasts, indicating that the new antibiotic-eluting wound dressings represent an effective option for selective treatment of bacterial infections. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Matsumura, Hajime; Imai, Ryutaro; Ahmatjan, Niyaz; Ida, Yukiko; Gondo, Masahide; Shibata, Dai; Wanatabe, Katsueki
2014-02-01
In recent years, adhesive wound dressings have been increasingly applied postoperatively because of their ease of use as they can be kept in place without having to cut and apply surgical tapes and they can cover a wound securely. However, if a wound dressing strongly adheres to the wound, a large amount of stratum corneum is removed from the newly formed epithelium or healthy periwound skin. Various types of adhesives are used on adhesive wound dressings and the extent of skin damage depends on how much an adhesive sticks to the wound or skin surface. We quantitatively determined and compared the amount of stratum corneum removed by eight different wound dressings including polyurethane foam using acrylic adhesive, silicone-based adhesive dressing, composite hydrocolloid and self-adhesive polyurethane foam in healthy volunteers. The results showed that wound dressings with silicone adhesive and self-adhesive polyurethane foam removed less stratum corneum, whereas composite hydrocolloid and polyurethane foam using acrylic adhesive removed more stratum corneum. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
The Effect of Offloading Heels on Sacral Pressure.
Al-Majid, Sadeeka; Vuncanon, Barbara; Carlson, Nika; Rakovski, Cyril
2017-09-01
Offloading a patient's heels during supine surgical procedures is a common practice to prevent heel pressure injuries. This practice may increase sacral pressure and jeopardize sacral skin integrity, but prophylactic dressings may help protect sacral skin. The purpose of this study was to examine the effects of offloading the heels and of multilayered silicone foam dressings on sacral pressure. We measured the sacral pressure of 50 healthy volunteers using a pressure-mapping system under four conditions: heels not offloaded and sacral dressing applied, heels offloaded and dressing applied, heels not offloaded and no dressing, and heels offloaded and no dressing. We used linear mixed-effects modeling to compare the effects of these conditions on sacral pressure. Offloading the heels significantly increased sacral pressure (P < .001), whereas the dressing had no effect on sacral pressure (P = .49). Offloading a patient's heels may increase the risk of sacral pressure injuries. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Dutra, J A P; Carvalho, S G; Zampirolli, A C D; Daltoé, R D; Teixeira, R M; Careta, F P; Cotrim, M A P; Oréfice, R L; Villanova, J C O
2017-04-01
Transparent, soft, flexible, mechanically resistant films, which are ideal for use as wound dressings were prepared in the presence of 2% papain, a proteolytic enzyme that can play a role in the chemical debridement of the skin and can accelerate the healing process. The films, based on poly(vinyl alcohol):calcium alginate blends with increasing concentrations of polysaccharide (10, 20, and 30% v/v), were obtained by casting method. FTIR and DSC analyses were performed to assess the composition and miscibility of blends. Mechanical properties such as tensile strength, elasticity modulus, and elongation at breakpoint were evaluated. The influence of different concentrations of calcium alginate on physical attributes of films like wettability, swelling capacity and mechanical properties was determined. The stability of papain in the films was assessed indirectly by hemolytic activity assay employing direct contact method and confirmed by technique based on blood agar diffusion. Preliminary cytotoxicity was evaluated with the XTT method. The results showed that at the polymer concentrations tested, the blends were miscible. The increase in the content of the calcium alginate increased the wettability and swelling capacity of the films, which is desirable in wound dressings. On the other hand, mechanical resistance decreased without causing breakage of the films during the swelling tests. The hemolytic activity of the films was maintained during the studied period, suggesting the stability of papain in the proposed formulations. Cellular viability indicated that the films were non-toxic. The analysis of the results showed that it is possible to prepare interactive and bioactive wound dressing containing papain from blends of PVA and calcium alginate polymers. Copyright © 2016 Elsevier B.V. All rights reserved.
A new postoperative otoplasty dressing technique using cyanoacrylate tissue adhesives.
Vetter, Miriam; Foehn, Matthias; Wedler, Volker
2010-04-01
There are many techniques for cosmetic surgery of the ears and also many different procedures for postoperative treatment. The postoperative dressing is described as important for a successful outcome. We present our method of postoperative dressing in the form of liquid bonding. Cyanoacrylate tissue adhesives as liquid bonding agents are used for fixation of the pinna at the mastoid area. After 10-14 days the bonding can be easily removed. No huge dressings, tapes, or plasters are necessary. The patients are satisfied with the light dressing; they do not feel ashamed to appear in public. We have found this dressing technique to be simple and economical, especially because of the use of the bonding for skin closure before. It can be used after otoplasty with an anterior or a posterior approach.
"What You Wear Tells a Lot about You:" Girls Dress Up Online
ERIC Educational Resources Information Center
Willett, Rebekah
2008-01-01
This article reports findings from a study in which 26 girls aged 12- to 13-years-old took part in workshops at a specialist ICT center connected to a school in inner-city London. The girls explored and discussed fashion as presented online, and they produced their own interactive fashion design webpages, making decisions about body shapes, types…
Identifying different mechanisms in the control of a nitrogen-vacancy center system
NASA Astrophysics Data System (ADS)
Li, Shouzhi; Yang, Ling; Cao, Dewen; Wang, Yaoxiong; Shuang, Feng; Gao, Fang
2017-10-01
The nitrogen-vacancy (NV) center system has shown great potential in quantum computing due to its long decoherence time at room temperature by encoding the qubit in dressed states [28]. The corresponding control mechanisms, which is expressed by the pathways linking the initial and target states, can be naturally investigated with the Hamiltonian-encoding and observable-decoding (HE-OD) method in the interaction adiabatic representation. This is proved by the fact that the mechanisms change slightly with different detunings, magnetic and driving field intensities, and the dominant pathway is always | g 〉 → | d 〉 → | g 〉 , with | g 〉 and | d 〉 as the first two lowest dressed states. Cases are different in the diabatic representation. The orders of dominant pathways increase the driving field intensities. Tendencies of quantum pathway amplitudes with driving fields, magnetic fields and detunings change at different conditions, which can be analyzed from the Dyson series. HE-OD analysis show that the two states | g 〉 and | d 〉 in the interaction adiabatic representation are preferable to be employed as a qubit than the state pair |0〉 and | - 1 〉 in the diabatic representation under the current Hamiltonian and parameters.
Dressed Wilson loops as dual condensates in response to magnetic and electric fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruckmann, Falk; Endroedi, Gergely
2011-10-01
We introduce dressed Wilson loops as a novel confinement observable. It consists of closed planar loops of arbitrary geometry but fixed area, and its expectation values decay with the latter. The construction of dressed Wilson loops is based on chiral condensates in response to magnetic and electric fields, thus linking different physical concepts. We present results for generalized condensates and dressed Wilson loops on dynamical lattice configurations and confirm the agreement with conventional Wilson loops in the limit of large probe mass. We comment on the renormalization of dressed Wilson loops.
The role of dressings in the prevention of pressure ulcers.
Brown, Julie
2016-08-11
Pressure ulceration is a significant global healthcare problem and represents a considerable burden on healthcare resources. Within the literature an increasing number of studies have examined the role prophylactic dressings play in redistributing pressure and helping to protect the skin from the effects of friction and shear. The use of dressings to prevent pressure ulcers may be considered a controversial issue, as previous opinion has been that dressings do not reduce the effects of pressure. This article will critically evaluate the literature to examine the role dressings play in the prevention of pressure ulceration.
Foam dressings for treating pressure ulcers.
Walker, Rachel M; Gillespie, Brigid M; Thalib, Lukman; Higgins, Niall S; Whitty, Jennifer A
2017-10-12
Pressure ulcers, also known as pressure injuries and bed sores, are localised areas of injury to the skin or underlying tissues, or both. Dressings made from a variety of materials, including foam, are used to treat pressure ulcers. An evidence-based overview of dressings for pressure ulcers is needed to enable informed decision-making on dressing use. This review is part of a suite of Cochrane Reviews investigating the use of dressings in the treatment of pressure ulcers. Each review will focus on a particular dressing type. To assess the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers in people with an existing pressure ulcer in any care setting. In February 2017 we searched: the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE (including In-Process & Other Non-Indexed Citations); Ovid Embase; EBSCO CINAHL Plus and the NHS Economic Evaluation Database (NHS EED). We also searched clinical trials registries for ongoing and unpublished studies, and scanned reference lists of relevant included studies as well as reviews, meta-analyses and health technology reports to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. Published or unpublished randomised controlled trials (RCTs) and cluster-RCTs, that compared the clinical and cost effectiveness of foam wound dressings for healing pressure ulcers (Category/Stage II or above). Two review authors independently performed study selection, risk of bias and data extraction. A third reviewer resolved discrepancies between the review authors. We included nine trials with a total of 483 participants, all of whom were adults (59 years or older) with an existing pressure ulcer Category/Stage II or above. All trials had two arms, which compared foam dressings with other dressings for treating pressure ulcers.The certainty of evidence ranged from low to very low due to various combinations of selection, performance, attrition, detection and reporting bias, and imprecision due to small sample sizes and wide confidence intervals. We had very little confidence in the estimate of effect of included studies. Where a foam dressing was compared with another foam dressing, we established that the true effect was likely to be substantially less than the study's estimated effect.We present data for four comparisons.One trial compared a silicone foam dressing with another (hydropolymer) foam dressing (38 participants), with an eight-week (short-term) follow-up. It was uncertain whether alternate types of foam dressing affected the incidence of healed pressure ulcers (RR 0.89, 95% CI 0.45 to 1.75) or adverse events (RR 0.37, 95% CI 0.04 to 3.25), as the certainty of evidence was very low, downgraded for serious limitations in study design and very serious imprecision.Four trials with a median sample size of 20 participants (230 participants), compared foam dressings with hydrocolloid dressings for eight weeks or less (short-term). It was uncertain whether foam dressings affected the probability of healing in comparison to hydrocolloid dressings over a short follow-up period in three trials (RR 0.85, 95% CI 0.54 to 1.34), very low-certainty evidence, downgraded for very serious study limitations and serious imprecision. It was uncertain if there was a difference in risk of adverse events between groups (RR 0.88, 95% CI 0.37 to 2.11), very low-certainty evidence, downgraded for serious study limitations and very serious imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but we assessed the evidence as being of very low certainty.One trial (34 participants), compared foam and hydrogel dressings over an eight-week (short-term) follow-up. It was uncertain if the foam dressing affected the probability of healing (RR 1.00, 95% CI 0.78 to 1.28), time to complete healing (MD 5.67 days 95% CI -4.03 to 15.37), adverse events (RR 0.33, 95% CI 0.01 to 7.65) or reduction in ulcer size (MD 0.30 cm 2 per day, 95% CI -0.15 to 0.75), as the certainty of the evidence was very low, downgraded for serious study limitations and very serious imprecision.The remaining three trials (181 participants) compared foam with basic wound contact dressings. Follow-up times ranged from short-term (8 weeks or less) to medium-term (8 to 24 weeks). It was uncertain whether foam dressings affected the probability of healing compared with basic wound contact dressings, in the short term (RR 1.33, 95% CI 0.62 to 2.88) or medium term (RR 1.17, 95% CI 0.79 to 1.72), or affected time to complete healing in the medium term (MD -35.80 days, 95% CI -56.77 to -14.83), or adverse events in the medium term (RR 0.58, 95% CI 0.33 to 1.05). This was due to the very low-certainty evidence, downgraded for serious to very serious study limitations and imprecision. Reduction in ulcer size, patient satisfaction/acceptability, pain and cost effectiveness data were also reported but again, we assessed the evidence as being of very low certainty.None of the included trials reported quality of life or pressure ulcer recurrence. It is uncertain whether foam dressings are more clinically effective, more acceptable to users, or more cost effective compared to alternative dressings in treating pressure ulcers. It was difficult to make accurate comparisons between foam dressings and other dressings due to the lack of data on reduction of wound size, complete wound healing, treatment costs, or insufficient time-frames. Quality of life and patient (or carer) acceptability/satisfaction associated with foam dressings were not systematically measured in any of the included studies. We assessed the certainty of the evidence in the included trials as low to very low. Clinicians need to carefully consider the lack of robust evidence in relation to the clinical and cost-effectiveness of foam dressings for treating pressure ulcers when making treatment decisions, particularly when considering the wound management properties that may be offered by each dressing type and the care context.
Ullman, Amanda J; Kleidon, Tricia; Gibson, Victoria; McBride, Craig A; Mihala, Gabor; Cooke, Marie; Rickard, Claire M
2017-08-30
Central venous access device (CVAD) associated complications are a preventable source of patient harm, frequently resulting in morbidity and delays to vital treatment. Dressing and securement products are used to prevent infectious and mechanical complications, however current complication rates suggest customary practices are inadequate. The aim of this study was to evaluate the feasibility of launching a full-scale randomized controlled efficacy trial of innovative dressing and securement products for pediatric tunneled CVAD to prevent complication and failure. An external, pilot, four-group randomized controlled trial of standard care (bordered polyurethane dressing and suture), in comparison to integrated securement-dressing, suture-less securement device, and tissue adhesive was undertaken across two large, tertiary referral pediatric hospitals in Australia. Forty-eight pediatric participants with newly inserted tunneled CVADs were consecutively recruited. The primary outcome of study feasibility was established by elements of eligibility, recruitment, attrition, protocol adherence, missing data, parent and healthcare staff satisfaction and acceptability, and effect size estimates for CVAD failure (cessation of function prior to completion of treatment) and complication (associated bloodstream infection, thrombosis, breakage, dislodgement or occlusion). Dressing integrity, product costs and site complications were also examined. Protocol feasibility was established. CVAD failure was: 17% (2/12) integrated securement-dressing; 8% (1/13) suture-less securement device; 0% tissue adhesive (0/12); and, 0% standard care (0/11). CVAD complications were: 15% (2/13) suture-less securement device (CVAD associated bloodstream infection, and occlusion and partial dislodgement); 8% (1/12) integrated securement-dressing (partial dislodgement); 0% tissue adhesive (0/12); and, 0% standard care (0/11). One CVAD-associated bloodstream infection occurred, within the suture-less securement device group. Overall satisfaction was highest in the integrated securement-dressing (mean 8.5/10; standard deviation 1.2). Improved dressing integrity was evident in the intervention arms, with the integrated securement-dressing associated with prolonged time to first dressing change (mean days 3.5). Improving the security and dressing integrity of tunneled CVADs is likely to improve outcomes for pediatric patients. Further research is necessary to identify novel, effective CVAD securement to reduce complications, and provide reliable vascular access for children. ACTRN12614000280606 ; prospectively registered on 17/03/2014.
Percutaneous urinary procedures - discharge
... a shower if you wrap the dressing with plastic wrap and replace the dressing if it gets ... include: Telfa (the dressing material), Tegaderm (the clear plastic tape that holds the plastic ring in place), ...
Fries, C A; Ayalew, Y; Penn-Barwell, J G; Porter, K; Jeffery, S L A; Midwinter, M J
2014-07-01
Recent conflicts have been characterised by the use of improvised explosive devices causing devastating injuries, including heavily contaminated wounds requiring meticulous surgical debridement. After being rendered surgical clean, these wounds are dressed and the patient transferred back to the UK for on-going treatment. A dressing that would prevent wounds from becoming colonised during transit would be desirable. The aim of this study was to establish whether using nanocrystalline silver dressings, as an adjunct to the initial debridement, would positively affect wound microbiology and wound healing compared to standard plain gauze dressings. Patients were prospectively randomised to receive either silver dressings, in a nanocrystalline preparation (Acticoat™), or standard of care dressings (plain gauze) following their initial debridement in the field hospital. On repatriation to the UK microbiological swabs were taken from the dressing and the wound, and an odour score recorded. Wounds were followed prospectively and time to wound healing was recorded. Additionally, patient demographic data were recorded, as well as the mechanism of injury and Injury Severity Score. 76 patients were recruited to the trial between February 2010 and February 2012. 39 received current dressings and 37 received the trial dressings. Eleven patients were not swabbed. There was no difference (p=0.1384, Fishers) in the primary outcome measure of wound colonisation between the treatment arm (14/33) and the control arm (20/32). Similarly time to wound healing was not statistically different (p=0.5009, Mann-Whitney). Wounds in the control group were scored as being significantly more malodorous (p=0.002, Mann-Whitney) than those in the treatment arm. This is the first randomised controlled trial to report results from an active theatre of war. Performing research under these conditions poses additional challenges to military clinicians. Meticulous debridement of wounds remains the critical determinant in wound healing and infection and this study did not demonstrate a benefit of nanocrystaline silver dressing in respect to preventing wound colonisation or promoting healing, these dressings do however seem to significantly reduce the unpleasant odour commonly associated with battlefield wounds. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Adiabatic Quantum Computation with Neutral Cesium
NASA Astrophysics Data System (ADS)
Hankin, Aaron; Parazzoli, L.; Chou, Chin-Wen; Jau, Yuan-Yu; Burns, George; Young, Amber; Kemme, Shanalyn; Ferdinand, Andrew; Biedermann, Grant; Landahl, Andrew; Ivan H. Deutsch Collaboration; Mark Saffman Collaboration
2013-05-01
We are implementing a new platform for adiabatic quantum computation (AQC) based on trapped neutral atoms whose coupling is mediated by the dipole-dipole interactions of Rydberg states. Ground state cesium atoms are dressed by laser fields in a manner conditional on the Rydberg blockade mechanism, thereby providing the requisite entangling interactions. As a benchmark we study a Quadratic Unconstrained Binary Optimization (QUBO) problem whose solution is found in the ground state spin configuration of an Ising-like model. University of New Mexico: Ivan H. Deutsch, Tyler Keating, Krittika Goyal.
Rydberg dressing of atoms in optical lattices
NASA Astrophysics Data System (ADS)
Macrı, T.; Pohl, T.
2014-01-01
We study atoms in optical lattices whose electronic ground state is off-resonantly coupled to a highly excited state with strong binary interactions. We present a time-dependent treatment of the resulting quantum dynamics, which—contrary to recent predictions [36 Li, Ates, and Lesanovsky, Phys. Rev. Lett. 110, 213005 (2013), 10.1103/PhysRevLett.110.213005]—proves that the strong repulsion between the weakly admixed Rydberg states does not lead to atomic trap loss. This finding provides an important basis for creating and manipulating coherent long-range interactions in optical lattice experiments.
Bernatchez, Stéphanie F.; Ruckly, Stéphane; Timsit, Jean-François
2015-01-01
Objective To model the cost-effectiveness impact of routine use of an antimicrobial chlorhexidine gluconate-containing securement dressing compared to non-antimicrobial transparent dressings for the protection of central vascular lines in intensive care unit patients. Design This study uses a novel health economic model to estimate the cost-effectiveness of using the chlorhexidine gluconate dressing versus transparent dressings in a French intensive care unit scenario. The 30-day time non-homogeneous markovian model comprises eight health states. The probabilities of events derive from a multicentre (12 French intensive care units) randomized controlled trial. 1,000 Monte Carlo simulations of 1,000 patients per dressing strategy are used for probabilistic sensitivity analysis and 95% confidence intervals calculations. The outcome is the number of catheter-related bloodstream infections avoided. Costs of intensive care unit stay are based on a recent French multicentre study and the cost-effectiveness criterion is the cost per catheter-related bloodstream infections avoided. The incremental net monetary benefit per patient is also estimated. Patients 1000 patients per group simulated based on the source randomized controlled trial involving 1,879 adults expected to require intravascular catheterization for 48 hours. Intervention Chlorhexidine Gluconate-containing securement dressing compared to non-antimicrobial transparent dressings. Results The chlorhexidine gluconate dressing prevents 11.8 infections /1,000 patients (95% confidence interval: [3.85; 19.64]) with a number needed to treat of 85 patients. The mean cost difference per patient of €141 is not statistically significant (95% confidence interval: [€-975; €1,258]). The incremental cost-effectiveness ratio is of €12,046 per catheter-related bloodstream infection prevented, and the incremental net monetary benefit per patient is of €344.88. Conclusions According to the base case scenario, the chlorhexidine gluconate dressing is more cost-effective than the reference dressing. Trial Registration This model is based on the data from the RCT registered with www.clinicaltrials.gov (NCT01189682). PMID:26086783
Desroche, N; Dropet, C; Janod, P; Guzzo, J
2016-10-02
This study was designed to evaluate the antibacterial activity of a wound dressing which combines polyacrylate fibres and a silver lipido-colloid matrix (UrgoClean Ag, silver polyabsorbent dressing), against biofilm of methicillin-resistant Staphylococcus aureus (MRSA). Samples of silver polyabsorbent dressing and the neutral form of this dressing (UrgoClean) were applied to biofilms of MRSA formed on a collagen I-coated surface, cultured for 24 hours. Different exposure times were tested (1, 2, 4 and 7 days) without dressing change. The biofilm reduction was quantified by using culture methods and by confocal laser scanning microscopy experiments. The application of the silver polyabsorbent dressing resulted in a significant decrease of the biofilm population by a log reduction of 4.6, after 24 hours of exposure. Moreover, the antibiofilm activity was maintained for 7 days with reduction values up to 4 log (reduction of biofilm superior to 99.99%). The application of the neutral dressing also induced a significant reduction of the concentration of sessile cells after 1 day (about 0.90 log). The results obtained with this neutral form of the dressing showed that the polyacrylate fibres were able to exert a mechanical disruption of the biofilm architecture. These in vitro experiments demonstrated that silver polyabsorbent dressing was able to strongly reduce the biofilm of MRSA. The antibiofilm mechanism of this dressing can be explained by a dual action of the polyabsorbent fibres (based on ammonium polyacrylate polymer around an acrylic core) which induced a mechanical disruption of the biofilm matrix and/or a sequestration of sessile cells, and the diffusion of silver ions which produced bactericidal activity. This study was supported by Laboratoires Urgo (Dijon). P. Janod is an employee of Laboratoires Urgo. The company had no influence on the experimental design and the interpretation of the results.
2010-01-01
Background The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. Methods In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Results Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Conclusions Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing. PMID:20576085
Nasir, Nur-Azida Mohd; Halim, Ahmad Sukari; Singh, Kirnpal-Kaur Banga; Dorai, Ananda Aravazhi; Haneef, Mehru-Nisha Muhammad
2010-06-24
The use of honey as a natural product of Apis spp. for burn treatment has been widely applied for centuries. Tualang honey has been reported to have antibacterial properties against various microorganisms, including those from burn-related diagnoses, and is cheaper and easier to be absorbed by Aquacel dressing. The aim of this study is to evaluate the potential antibacterial properties of tualang honey dressing and to determine its effectiveness as a partial thickness burn wound dressing. In order to quantitate the bioburden of the swabs, pour plates were performed to obtain the colony count (CFU/ml). Swabs obtained from burn wounds were streaked on blood agar and MacConkey agar for bacterial isolation and identification. Later, antibacterial activity of Aquacel-tualang honey, Aquacel-Manuka honey, Aquacel-Ag and Aquacel- plain dressings against bacteria isolated from patients were tested (in-vitro) to see the effectiveness of those dressings by zone of inhibition assays. Seven organisms were isolated. Four types of Gram-negative bacteria, namely Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas spp. and Acinetobacter spp., and three Gram-positive bacteria, namely Staphylococcus aureus, coagulase-negative Staphylococcus aureus (CONS) and Streptococcus spp., were isolated. Total bacterial count decreased on day 6 and onwards. In the in-vitro antibacterial study, Aquacel-Ag and Aquacel-Manuka honey dressings gave better zone of inhibition for Gram positive bacteria compared to Aquacel-Tualang honey dressing. However, comparable results were obtained against Gram negative bacteria tested with Aquacel-Manuka honey and Aquacel-Tualang honey dressing. Tualang honey has a bactericidal as well as bacteriostatic effect. It is useful as a dressing, as it is easier to apply and is less sticky compared to Manuka honey. However, for Gram positive bacteria, tualang honey is not as effective as usual care products such as silver-based dressing or medical grade honey dressing.
Brena-Molina, Ana; Martínez-López, Valentín; Melgarejo-Ramírez, Yaaziel; Tamay de Dios, Lenin; Gómez-García, Ricardo; Reyes-Frías, Ma. de Lourdes; Rodríguez-Rodríguez, Lourdes; Garciadiego-Cázares, David; Lugo-Martínez, Haydée; Ibarra, Clemente
2015-01-01
Human adipose-derived mesenchymal stem cells (hADMSCs) are believed to be potential key factors for starting the regenerative process after tissue injury. However, an efficient method of delivering these regenerative cells to an external wound site is still lacking. Human amnion and pig skin have long been used as skin wound dressings for the treatment of burns and other skin lesions. Herein, we present the generation of two constructs using these two biomaterials as effective scaffolds for the culture of hADMSCs. It was found that hADMSCs seeded onto radiosterilized human amnion and pig skin are viable and proliferate. These cells are able to migrate over these scaffolds as demonstrated by using time-lapse microscopy. In addition, the scaffolds induce hADMSCs to secrete interleukin-10, an important negative regulator of inflammation, and interleukin-1β, a proinflammatory protein. The interplay between these two proteins has been proven to be vital for a balanced restoration of all necessary tissues. Thus, radiosterilized human amnion and pig skin are likely suitable scaffolds for delivery of hADMSCs transplants that could promote tissue regeneration in skin injuries like patients with burn injuries. PMID:26418201
Konstantatos, A H; Angliss, M; Costello, V; Cleland, H; Stafrace, S
2009-06-01
Pain arising in burns sufferers is often severe and protracted. The prospect of a dressing change can heighten existing pain by impacting both physically and psychologically. In this trial we examined whether pre-procedural virtual reality guided relaxation added to patient controlled analgesia with morphine reduced pain severity during awake dressings changes in burns patients. We conducted a prospective randomized clinical trial in all patients with burns necessitating admission to a tertiary burns referral centre. Eligible patients requiring awake dressings changes were randomly allocated to single use virtual reality relaxation plus intravenous morphine patient controlled analgesia (PCA) infusion or to intravenous morphine patient controlled analgesia infusion alone. Patients rated their worst pain intensity during the dressing change using a visual analogue scale. The primary outcome measure was presence of 30% or greater difference in pain intensity ratings between the groups in estimation of worst pain during the dressing change. Of 88 eligible and consenting patients having awake dressings changes, 43 were assigned to virtual reality relaxation plus intravenous morphine PCA infusion and 43 to morphine PCA infusion alone. The group receiving virtual reality relaxation plus morphine PCA infusion reported significantly higher pain intensities during the dressing change (mean=7.3) compared with patients receiving morphine PCA alone (mean=5.3) (p=0.003) (95% CI 0.6-2.8). The addition of virtual reality guided relaxation to morphine PCA infusion in burns patients resulted in a significant increase in pain experienced during awake dressings changes. In the absence of a validated predictor for responsiveness to virtual reality relaxation such a therapy cannot be recommended for general use in burns patients having awake dressings changes.
Dhillon, M; Carter, C P; Morrison, J; Hislop, W S; Currie, W J R
2015-06-01
The success of skin grafting is dependent on the interplay between many factors including nutrient uptake and vascular in-growth. To allow this, it is important that the graft is immobile and traditionally a 'pressure dressing' has been placed over the graft to improve outcome and graft 'take'. We present the findings of our comparative study of full-thickness skin grafts performed in the head, neck and face region over a period of 24 months. We felt that there was an unacceptably high infection rate and graft failure using pressure dressings. Data was collected retrospectively from the case notes on 70 patients who had undergone full-thickness skin grafting to the head, neck and face over a 2 year period. Thirty-five patients underwent grafting with pressure dressing and 35 without. The group with the pressure dressing had the same 'bolster' specification-type dressing and those without had their graft 'quilted' in and chloramphenicol ointment applied topically. Success was determined by the percentage 'take' of the grafts and absence of infection i.e. purulence. Infection in those with a pressure dressing stood at 26 % in contrast to those without, at 9 %. Without a pressure dressing we observed no total graft failures, compared to 6 % in those with a pressure dressing. The results confirmed the perception that there was a higher infection and graft failure rate where a pressure dressing was applied; however, this was not a statistically significant difference and a randomised control trial with a larger sample size would be required to validate the results.
Leaper, David; Nazir, Jameel; Roberts, Chris; Searle, Richard
2010-01-01
In patients at risk of surgical site infection (SSI), there is evidence that an antimicrobial barrier dressing (Acticoat* ) applied immediately post-procedure is effective in reducing the incidence of infection. The objective of this study was to assess when it is appropriate to use an antimicrobial barrier dressing rather than a post-operative film dressing, by evaluating the net cost and budget impact of the two strategies. An economic model was developed, which estimates expected expenditure on dressings and the expected costs of surgical site infection during the initial inpatient episode, based on published literature on the pre-discharge costs of surgical infection and the efficacy of an antimicrobial barrier dressing in preventing SSI. At an SSI risk of 10%, an antimicrobial barrier dressing strategy is cost neutral if the incidence of infection is reduced by at least 9% compared with a post-operative film dressing. At 35% efficacy, expenditure on dressings would be higher by £30,760 per 1000 patients, and the cost of treating infection would be lower by £111,650, resulting in a net cost saving of £80,890. The break-even infection risk for cost neutrality is 2.6%. Although this cost analysis is based on published data, there are limitations in methodology: the model is dependent on and subject to the limitations of the data used to populate it. Further studies would be useful to increase the robustness of the conclusions, particularly in a broader range of surgical specialties. A strategy involving the use of an antimicrobial barrier dressing in patients at moderate (5-10%) or high (>10%) risk of infection appears reasonable and cost saving in light of the available clinical evidence.
Toon, Clare D; Lusuku, Charnelle; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2015-09-03
Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In March 2015 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.
Toon, Clare D; Ramamoorthy, Rajarajan; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2013-09-05
Most surgical procedures involve a cut in the skin that allows the surgeon to gain access to the deeper tissues or organs. Most surgical wounds are closed fully at the end of the procedure (primary closure). The surgeon covers the closed surgical wound with either a dressing or adhesive tape. The dressing can act as a physical barrier to protect the wound until the continuity of the skin is restored (within about 48 hours) and to absorb exudate from the wound, keeping it dry and clean, and preventing bacterial contamination from the external environment. Some studies have found that the moist environment created by some dressings accelerates wound healing, although others believe that the moist environment can be a disadvantage, as excessive exudate can cause maceration (softening and deterioration) of the wound and the surrounding healthy tissue. The utility of dressing surgical wounds beyond 48 hours of surgery is, therefore, controversial. To evaluate the benefits and risks of removing a dressing covering a closed surgical incision site within 48 hours permanently (early dressing removal) or beyond 48 hours of surgery permanently with interim dressing changes allowed (delayed dressing removal), on surgical site infection. In July 2013 we searched the following electronic databases: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. We also searched the references of included trials to identify further potentially-relevant trials. Two review authors independently identified studies for inclusion. We included all randomised clinical trials (RCTs) conducted with people of any age and sex, undergoing a surgical procedure, who had their wound closed and a dressing applied. We included only trials that compared early versus delayed dressing removal. We excluded trials that included people with contaminated or dirty wounds. We also excluded quasi-randomised studies, and other study designs. Two review authors independently extracted data on the characteristics of the trial participants, risk of bias in the trials and outcomes for each trial. We calculated risk ratios (RR) with 95% confidence intervals (CI) for binary outcomes and mean difference (MD) with 95% CI for continuous outcomes. We used RevMan 5 software to perform these calculations. Four trials were identified for inclusion in this review. All the trials were at high risk of bias. Three trials provided information for this review. Overall, this review included 280 people undergoing planned surgery. Participants were randomised to early dressing removal (removal of the wound dressing within the 48 hours following surgery) (n = 140) or delayed dressing removal (continued dressing of the wound beyond 48 hours) (n = 140) in the three trials. There were no statistically significant differences between the early dressing removal group and delayed dressing removal group in the proportion of people who developed superficial surgical site infection within 30 days (RR 0.64; 95% CI 0.32 to 1.28), superficial wound dehiscence within 30 days (RR 2.00; 95% CI 0.19 to 21.16) or serious adverse events within 30 days (RR 0.83; 95% CI 0.28 to 2.51). No deep wound infection or deep wound dehiscence occurred in any of the participants in the trials that reported this outcome. None of the trials reported quality of life. The hospital stay was significantly shorter (MD -2.00 days; 95% CI -2.82 to -1.18) and the total cost of treatment significantly less (MD EUR -36.00; 95% CI -59.81 to -12.19) in the early dressing removal group than in the delayed dressing removal group in the only trial that reported these outcomes. The early removal of dressings from clean or clean contaminated surgical wounds appears to have no detrimental effect on outcomes. However, it should be noted that the point estimate supporting this statement is based on very low quality evidence from three small randomised controlled trials, and the confidence intervals around this estimate were wide. Early dressing removal may result in a significantly shorter hospital stay, and significantly reduced costs, than covering the surgical wound with wound dressings beyond the first 48 hours after surgery, according to very low quality evidence from one small randomised controlled trial. Further randomised controlled trials of low risk of bias are necessary to investigate whether dressings are necessary after 48 hours in different types of surgery and levels of contamination and investigate whether antibiotic therapy influences the outcome.
Pediatric Digital Necrosis Secondary to Dressing Application: A Case Series.
Bjorklund, Kim A; Rice, Dahlia M; Amalfi, Ashley N
2018-04-01
Pediatric digital necrosis resulting in revision amputation is a devastating outcome following digital dressing application. We report a series of 4 pediatric patients (age: 21 months-11 years) who presented for surgical consultation related to digital ischemia and irreversible necrosis following the application of Coban digital dressings. A review of the literature demonstrated that such injuries had not previously been described. In our case series, Coban dressing was utilized as a deterrent for thumb sucking, fingertip tuft fractures with nail bed lacerations, and a phalanx fracture secondary to crush injury. All 4 children suffered digital necrosis secondary to Coban dressings and ultimately required revision amputation. We discuss risks factors, application practices, and strategies to minimize complications with digital dressings in the pediatric population with the intent of creating awareness among hand surgeons to help promote safe practices and improve patient outcomes.
Heffernan, A; Martin, A J
1994-01-01
A clinical study of 96 patients compared a new hydrocolloid dressing (Granuflex Extra Thin) with a non-adherent dressing (perforated film absorbent dressing) in the management of lacerations, abrasions and minor operation incisions at the Accident and Emergency (A&E) Department of the University College Hospital, Galway. While time to heal was similar for both groups, the patients using Granuflex Extra Thin experienced less pain (P < 0.001), required less analgesia (P = 0.0154) and were able to carry out their normal daily activities including bathing or showering without affecting the dressing or the wound. Patient satisfaction with the new dressing appeared to be very high especially in those patients who pursued an active lifestyle. PMID:7894807
Elsner, Jonathan J; Egozi, Dana; Ullmann, Yehuda; Berdicevsky, Israela; Shefy-Peleg, Adaya; Zilberman, Meital
2011-08-01
Approximately 70% of all people with severe burns die from related infections despite advances in treatment regimens and the best efforts of nurses and doctors. Silver ion-eluting wound dressings are available for overcoming this problem. However, there are reports of deleterious effects of such dressings due to cellular toxicity that delays the healing process, and the dressing changes needed 1-2 times a day are uncomfortable for the patient and time consuming for the stuff. An alternative concept in wound dressing design that combines the advantages of occlusive dressings with biodegradability and intrinsic topical antibiotic treatment is described herewith. The new composite structure presented in this article is based on a polyglyconate mesh and a porous poly-(dl-lactic-co-glycolic acid) matrix loaded with gentamicin developed to provide controlled release of antibiotics for three weeks. In vivo evaluation of the dressing material in contaminated deep second degree burn wounds in guinea pigs (n=20) demonstrated its ability to accelerate epithelialization by 40% compared to an unloaded format of the material and a conventional dressing material. Wound contraction was reduced significantly, and a better quality scar tissue was formed. The current dressing material exhibits promising results, does not require frequent bandage changes, and offers a potentially valuable and economic approach to treating the life-threatening complication of burn-related infections. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.
Release of antibiotics from collagen dressing.
Grzybowski, J; Antos-Bielska, M; Ołdak, E; Trafny, E A
1997-01-01
Our new collagen dressing has been developed recently. Three types (A, B, and C) of the dressing were prepared in this study. Each type contained bacitracin, neomycin or colistin. The antibiotic was input into: i. collagen sponge (CS)--type A, ii. layer of limited hydrophobicity (LLH)--type B, and iii. into both CS and LLH layers--type C. The final concentration of the antibiotic that resulted from the loading level was 2 mg/cm2 for the dressings of type A and B and 4 mg/cm2 for the dressing of type C. The antibiotics were then extracted from the pieces of dressings for two days through dialysis membrane. Susceptibility of 54 bacterial strains (S. aureus, P. aeruginosa, and Acinetobacter) isolated from burn wounds were tested to the three antibiotics used for preparation of the dressings. The results of the study evidenced that efficiency of released of antibiotics into the extracts depended on the kind of antibiotic and on the type of dressing. The concentration of the antibiotics proved to be much higher than MIC90 values of the bacterial isolates tested in respect to their susceptibility. The dressing containing mixture of the three antibiotics in two layers--CS and LLH is now considered as potentially effective for care of infected wounds. It may be useful for the treatment of infected wounds or for profilaxis of contaminated wounds, ensuring: i. sufficient antimicrobial activity in wound, and ii. optimal wound environment for the presence of collagenic biomaterial on the damaged tissue.
Chitosan: A potential biopolymer for wound management.
Bano, Ijaz; Arshad, Muhammad; Yasin, Tariq; Ghauri, Muhammad Afzal; Younus, Muhammad
2017-09-01
It has been seen that slow healing and non-healing wounds conditions are treatable but still challenging to humans. Wound dressing usually seeks for biocompatible and biodegradable recipe. Natural polysaccharides like chitosan have been examined for its antimicrobial and healing properties on the basis of its variation in molecular weight and degree of deacetylation. Chitosan adopts some vital characteristics for treatment of various kinds of wounds which include its bonding nature, antifungal, bactericidal and permeability to oxygen. Chitosan therefore has been modified into various forms for the treatment of wounds and burns. The purpose of this review article is to understand the exploitation of chitosan and its derivatives as wound dressings. This article will also provide a concise insight on the properties of chitosan necessary for skin healing and regeneration, particularly highlighting the emerging role of chitosan films as next generation skin substitutes for the treatment of full thickness wounds. Copyright © 2017 Elsevier B.V. All rights reserved.
Bi-Layer Wound Dressing System for Combat Casualty Care
2004-09-01
C. Bonacorsi, M.S.G. Raddi, and I.Z. Carlos. 2004. Cytotoxicity of chlorhexidine digluconate to murine macrophages and its effect on hydrogen...chlorexhidine digluconate or 1 % chloramphenicol, as described previously. Each experimental dressing was then covered with a piece of sterile parafilm...chloramphenicol-loaded dressings were 2-log lower for the first 24 h than when applying the chlorhexidine -loaded dressings (Figure 2). However, there was no
Mendes, D A; Veiga, D F; Veiga-Filho, J; Loyola, A B A T; Paiva, L F; Novo, N F; Sabino-Neto, M; Ferreira, L M
2018-06-01
Concepts regarding the best way to treat a surgical wound vary, in literature, ranging from no dressing use to dressing maintenance for 24 to 48 hours or until suture removal. This study aimed to evaluate the influence of the length of dressing maintenance after breast augmentation with implants on cutaneous colonization and surgical site infection. This is a two-arm, parallel group, randomized clinical trial. Eighty patients who were candidates for augmentation mammoplasty with silicone implants were randomly allocated to two groups, in which the dressing was removed on postoperative day 1 (group A, n = 40) or postoperative day 6 (group B, n = 40). Cutaneous colonization was examined by culturing samples collected before and after dressing removal. The criteria defined by the Centers for Disease Control and Prevention were used to assess surgical site infection. No significant difference regarding cutaneous colonization was observed between groups before dressing application. On postoperative day 6, significantly more bacterial growth was observed in group A (p = 0.01). No surgical site infection occurred. We concluded that maintaining the dressing for 6 days led to a lower cutaneous colonization but did not influence surgical site infection rates. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The clinical and cost effectiveness of bee honey dressing in the treatment of diabetic foot ulcers.
Moghazy, A M; Shams, M E; Adly, O A; Abbas, A H; El-Badawy, M A; Elsakka, D M; Hassan, S A; Abdelmohsen, W S; Ali, O S; Mohamed, B A
2010-09-01
Honey is known, since antiquity, as an effective wound dressing. Emergence of resistant strains and the financial burden of modern dressings, have revived honey as cost-effective dressing particularly in developing countries. Its suitability for all stages of wound healing suggests its clinical effectiveness in diabetic foot wound infections. Thirty infected diabetic foot wounds were randomly selected from patients presenting to Surgery Department, Suez Canal University Hospital, Ismailia, Egypt. Honey dressing was applied to wounds for 3 months till healing, grafting or failure of treatment. Changes in grade and stage of wounds, using University of Texas Diabetic Wound Classification, as well as surface area were recorded weekly. Bacterial load was determined before and after honey dressing. Complete healing was significantly achieved in 43.3% of ulcers. Decrease in size and healthy granulation was significantly observed in another 43.3% of patients. Bacterial load of all ulcers was significantly reduced after the first week of honey dressing. Failure of treatment was observed in 6.7% of ulcers. This study proves that commercial clover honey is a clinical and cost-effective dressing for diabetic wound in developing countries. It is omnipresence and concordance with cultural beliefs makes it a typical environmentally based method for treating these conditions. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
Milne, Stephen D; Seoudi, Ihab; Al Hamad, Hanadi; Talal, Talal K; Anoop, Anzila A; Allahverdi, Niloofar; Zakaria, Zain; Menzies, Robert; Connolly, Patricia
2016-12-01
Wound moisture is known to be a key parameter to ensure optimum healing conditions in wound care. This study tests the moisture content of wounds in normal practice in order to observe the moisture condition of the wound at the point of dressing change. This study is also the first large-scale observational study that investigates wound moisture status at dressing change. The WoundSense sensor is a commercially available moisture sensor which sits directly on the wound in order to find the moisture status of the wound without disturbing or removing the dressing. The results show that of the 588 dressing changes recorded, 44·9% were made when the moisture reading was in the optimum moisture zone. Of the 30 patients recruited for this study, 11 patients had an optimum moisture reading for at least 50% of the measurements before dressing change. These results suggest that a large number of unnecessary dressing changes are being made. This is a significant finding of the study as it suggests that the protocols currently followed can be modified to allow fewer dressing changes and less disturbance of the healing wound bed. © 2015 The Authors. International Wound Journal published by Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Seeing "the Dress" in the Right Light: Perceived Colors and Inferred Light Sources.
Chetverikov, Andrey; Ivanchei, Ivan
2016-08-01
In the well-known "dress" photograph, people either see the dress as blue with black stripes or as white with golden stripes. We suggest that the perception of colors is guided by the scene interpretation and the inferred positions of light sources. We tested this hypothesis in two online studies using color matching to estimate the colors observers see, while controlling for individual differences in gray point bias and color discrimination. Study 1 demonstrates that the interpretation of the dress corresponds to differences in perceived colors. Moreover, people who perceive the dress as blue-and-black are two times more likely to consider the light source as frontal, than those who see the white-and-gold dress. The inferred light sources, in turn, depend on the circadian changes in ambient light. The interpretation of the scene background as a wall or a mirror is consistent with the perceived colors as well. Study 2 shows that matching provides reliable results on differing devices and replicates the findings on scene interpretation and light sources. Additionally, we show that participants' environmental lighting conditions are an important cue for perceiving the dress colors. The exact mechanisms of how environmental lighting and circadian changes influence the perceived colors of the dress deserve further investigation.
Technics study on high accuracy crush dressing and sharpening of diamond grinding wheel
NASA Astrophysics Data System (ADS)
Jia, Yunhai; Lu, Xuejun; Li, Jiangang; Zhu, Lixin; Song, Yingjie
2011-05-01
Mechanical grinding of artificial diamond grinding wheel was traditional wheel dressing process. The rotate speed and infeed depth of tool wheel were main technics parameters. The suitable technics parameters of metals-bonded diamond grinding wheel and resin-bonded diamond grinding wheel high accuracy crush dressing were obtained by a mount of experiment in super-hard material wheel dressing grind machine and by analysis of grinding force. In the same time, the effect of machine sharpening and sprinkle granule sharpening was contrasted. These analyses and lots of experiments had extent instruction significance to artificial diamond grinding wheel accuracy crush dressing.
Tiny patients, tiny dressings: a guide to the neonatal PICC dressing change.
Sharpe, Elizabeth L
2008-06-01
Advances in neonatology now support the survival of the tiniest of infants. The peripherally inserted central catheter (PICC) has now become an integral part of routine practice in neonatal intensive care units around the world. Keen attention to safe maintenance of these devices is essential. A properly applied and maintained PICC dressing is the first line of defense to minimize the risk of complications such as dislodgement, migration, and infection. This article describes a neonatal PICC dressing change and discusses the frequently encountered quandaries surrounding this important procedure, including dressing materials, frequency, site preparation, barrier precautions, and other relevant concerns.
Constructing medical social authority on dress in Victorian Canada.
O'Connor, Eileen
2008-01-01
During the late-Victorian period, campaigns to "reform" middle-class women's dress were grounded in discourses on health, eugenics, declining birth rates, comfort, and aesthetics. In Britain, the United States and Germany, organized "dress reform" movements emerged in the latter half of the 19th century, while in Canada the campaign was led primarily by physicians through public health education. This article explores the discussion on women's dress in public health literature in Canadian circulation between 1860-1900 and interprets findings within a feminist poststructuralist framework that posits the understanding of women's bodies and gender regulation to be central to knowledge construction on women's dress.
Bonferoni, Maria Cristina; Sandri, Giuseppina; Rossi, Silvia; Dellera, Eleonora; Invernizzi, Alessandro; Boselli, Cinzia; Cornaglia, Antonia Icaro; Del Fante, Claudia; Perotti, Cesare; Vigani, Barbara; Riva, Federica; Caramella, Carla; Ferrari, Franca
2018-02-09
Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds.
Bonferoni, Maria Cristina; Dellera, Eleonora; Invernizzi, Alessandro; Cornaglia, Antonia Icaro; Perotti, Cesare; Vigani, Barbara; Caramella, Carla; Ferrari, Franca
2018-01-01
Chitosan oleate was previously proposed to encapsulate in nanocarriers some poorly soluble molecules aimed to wound therapy, such as the anti-infective silver sulfadiazine, and the antioxidant α tocopherol. Because nanocarriers need a suitable formulation to be administered to wounds, in the present paper, these previously developed nanocarriers were loaded into freeze dried dressings based on chitosan glutamate. These were proposed as bioactive dressings aimed to support the application to wounds of platelet lysate, a hemoderivative rich in growth factors. The dressings were characterized for hydration capacity, morphological aspect, and rheological and mechanical behavior. Although chitosan oleate nanocarriers clearly decreased the mechanical properties of dressings, these remained compatible with handling and application to wounds. Preliminary studies in vitro on fibroblast cell cultures demonstrated good compatibility of platelet lysate with nanocarriers and bioactive dressings. An in vivo study on a murine wound model showed an accelerating wound healing effect for the bioactive dressing and its suitability as support of the platelet lysate application to wounds. PMID:29425164
Boonbaichaiyapruck, S; Hutayanon, P; Chanthanamatta, P; Dumrongwatana, T; Intarayotha, N; Krisdee, V; Yamvong, S
2001-12-01
Post cardiac catheterization puncture site care is usually done with a tight pressure dressing by an elastic adhesive bandage (Tensoplast) due to the belief that it should prevent bleeding. The practice is uncomfortable to the patients. The authors compared a new way of dressing using light transparent tape (Tegaderm) to the conventional tight pressure one. 126 post coronary angiography patients were randomized to have their groins dressed either with Tensoplast or with Tegaderm. Patients ambulated 8 hours after the procedures. The groin was evaluated for pain, discomfort and bleeding complications. 49 per cent in the Tensoplast vs 26.9 per cent in the Tegaderm group experienced pain (p value of 0.01). 55.5 per cent in the Tensoplast group vs 11.1 per cent in the Tegaderm group reported discomfort. 4.7 per cent in the Tensoplast vs 1.6 per cent in the Tegaderm group developed bleeding or hematoma. Dressing of the puncture site after cardiac catheterization with Tegaderm was more comfortable than the conventional Tensoplast without any difference in bleeding complications.
Effects of honey and sugar dressings on wound healing.
Mphande, A N G; Killowe, C; Phalira, S; Jones, H Wynn; Harrison, W J
2007-07-01
To investigate whether there is a difference between the efficacy of honey and sugar as wound dressings. Patients with open or infected wounds were randomised to receive either honey or sugar dressings. Bacterial colonisation, wound size, wound ASEPSIS score and pain were assessed at the start of treatment and at weekly intervals until full healing occurred. Forty patients were enrolled; 18 received sugar dressings and 22 honey dressings. In the honey group, 55% of patients had positive wound cultures at the start of treatment and 23% at one week, compared with 52% and 39% respectively in the sugar group.The median rate of healing in the first two weeks of treatment was 3.8cm2/week for the honey group and 2.2cm2/week for the sugar group. After three weeks of treatment 86% of patients treated with honey had no pain during dressing changes, compared with 72% treated with sugar. Honey appears to be more effective than sugar in reducing bacterial contamination and promoting wound healing, and slightly less painful than sugar during dressing changes and motion.
Development and validation of an online interactive, multimedia wound care algorithms program.
Beitz, Janice M; van Rijswijk, Lia
2012-01-01
To provide education based on evidence-based and validated wound care algorithms we designed and implemented an interactive, Web-based learning program for teaching wound care. A mixed methods quantitative pilot study design with qualitative components was used to test and ascertain the ease of use, validity, and reliability of the online program. A convenience sample of 56 RN wound experts (formally educated, certified in wound care, or both) participated. The interactive, online program consists of a user introduction, interactive assessment of 15 acute and chronic wound photos, user feedback about the percentage correct, partially correct, or incorrect algorithm and dressing choices and a user survey. After giving consent, participants accessed the online program, provided answers to the demographic survey, and completed the assessment module and photographic test, along with a posttest survey. The construct validity of the online interactive program was strong. Eighty-five percent (85%) of algorithm and 87% of dressing choices were fully correct even though some programming design issues were identified. Online study results were consistently better than previously conducted comparable paper-pencil study results. Using a 5-point Likert-type scale, participants rated the program's value and ease of use as 3.88 (valuable to very valuable) and 3.97 (easy to very easy), respectively. Similarly the research process was described qualitatively as "enjoyable" and "exciting." This digital program was well received indicating its "perceived benefits" for nonexpert users, which may help reduce barriers to implementing safe, evidence-based care. Ongoing research using larger sample sizes may help refine the program or algorithms while identifying clinician educational needs. Initial design imperfections and programming problems identified also underscored the importance of testing all paper and Web-based programs designed to educate health care professionals or guide patient care.
The brain's dress code: How The Dress allows to decode the neuronal pathway of an optical illusion.
Schlaffke, Lara; Golisch, Anne; Haag, Lauren M; Lenz, Melanie; Heba, Stefanie; Lissek, Silke; Schmidt-Wilcke, Tobias; Eysel, Ulf T; Tegenthoff, Martin
2015-12-01
Optical illusions have broadened our understanding of the brain's role in visual perception. A modern day optical illusion emerged from a posted photo of a striped dress, which some perceived as white and gold and others as blue and black. Here we show, using functional magnetic resonance imaging (fMRI), that those who perceive The Dress as white/gold have higher activation in response to the image of The Dress in brain regions critically involved in higher cognition (frontal and parietal brain areas). These results are consistent with theories of top-down modulation and present a neural signature associated with the differences in perceiving The Dress as white/gold or blue/black. Furthermore the results support recent psychophysiological data on this phenomenon and provide a fundamental building block to study interindividual differences in visual processing. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Felgueiras, H. P.; Amorim, M. T. P.
2017-10-01
Modern wound dressings combine medical textiles with active compounds that stimulate wound healing while protecting against infection. Electrospun wound dressings have been extensively studied and the electrospinning technique recognized as an efficient approach for the production of nanoscale fibrous mats. The unique diverse function and architecture of antimicrobial peptides (AMPs) has attracted considerable attention as a tool for the design of new anti-infective drugs. Functionalizing electrospun wound dressings with these AMPs is nowadays being researched. In the present work, we explore these new systems by highlighting the most important characteristics of electropsun wound dressings, revealing the importance of AMPs to wound healing, and the methods available to functionalize the electrospun mats with these molecules. The combined therapeutic potential of collagen type I and these AMP functionalized dressings will be highlighted as well; the significance of these new strategies for the future of wound healing will be clarified.
[Split-thickness skin graft donor site: which dressing use?].
Caliot, J; Bodin, F; Chiriac, S; Correia, N; Poli-Mérol, M-L; François-Fiquet, C
2015-04-01
The management of split-thickness skin graft donor sites is targeted towards promoting the healing process, reducing pain. This has been an inconclusive topic. The aim of this study was to list and to discuss the French practices in term of split-thickness skin graft (STSG) donor site dressing. Multicentric national study by questionnaire (Google Drive(®)) for the attention of the plastic and/or pediatric surgeons. The type of dressing used on skin and sclap and the rhythm of dressing changes were analyzed. The study included 26 surgical centers on 40 contacted. The alginate is mainly used (Algostéril(®)) (17/26). It is left in position until healing (13/17). Five other types of dressings have been reported: paraffin gauze (3/26), lipidocolloides (1/26), Mepitel(®) (1/26), Mepilex(®) (1/26), indifferent use of gauze or alginate dressings (4/26). Twenty-two out of 26 centers make no difference in dressing choice between skin and scalp. Medical practices did not differ between adult or pediatric departments. Cost-effectiveness has become an important issue in wound management, requiring judicious use. The lack of consensus regarding split-thickness skin graft donor site dressing and our clinical practices force us to reconsider the best therapeutic option. This study coupled with the analysis of the literature highlights the difficulties of the practitioner in choosing the best dressing. The alginate seems to get the preference of our practices by its ease of use, its absence of change (reduces pain by limiting manipulations) and its moderate cost. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
A comparison of an antibacterial sandwich dressing vs dressing containing silver.
Krasowski, Grzegorz; Jawień, Arkadiusz; Tukiendorf, Andrzej; Rybak, Zbigniew; Junka, Adam; Olejniczak-Nowakowska, Małgorzata; Bartoszewicz, Marzenna; Smutnicka, Danuta
2015-01-01
The purpose of this study was to compare the efficacy of dressings containing octenidine vs. dressings containing silver in the wound healing in the course of a chronic venous disease. There were two groups of 40 patients who met the inclusion criteria and who did not meet the exclusion criteria. The patients were randomly assigned into the groups (envelope method). The first, "O group" was treated with octenidine-based dressings. The second, "S group" was treated with silver dressings. The study lasted for 56 days. All patients in the research were treated with medical compression stockings with cotton understockings. Microbiological eradication was observed on the 28th day of the study among 33% of patients in the treatment group vs. 6% in control group. On the 56th day of the treatment, these percentages equalled 72% and 35%. The rate of healing was faster in the 0 group than in the S group. In the wounds <10 cm(2) it was faster by 1.35 cm(2)/week and in wounds >10 cm(2) it equalled 3.44 cm(2). The reduction of pain level was 37.5% higher in the O group, in contrast with the S group. One change of a dressing in the O group led to a 0.06 cm(2) greater wound size reduction and in the case of wounds >10 cm(2) to 0.29 cm(2) reduction compared with the S group. The presented results indicate that the efficacy of dressings containing octenidine is higher compared to silver dressings. © 2015 by the Wound Healing Society.
Jung, Jae-A; Yoo, Ki-Hyun; Han, Seung-Kyu; Dhong, Eun-Sang; Kim, Woo-Kyung
2016-12-01
To demonstrate the efficacy of a highly hydrophilic polyurethane foam dressing in the treatment of diabetic ulcers. Diabetic foot ulcers often pose a difficult treatment problem. Polyurethane foam dressings have been used worldwide to accelerate wound healing, but only a few clinical studies demonstrate the effect of foam dressing on the healing of diabetic ulcers. Medical records of 1342 patients with diabetic ulcers who were admitted and treated at the authors' institution were reviewed. A total of 208 patients met the study's inclusion criteria. Of these 208 patients, 137 were treated with a highly hydrophilic polyurethane foam dressing, and 71 were treated with saline gauze (control group). Except for the application of polyurethane foam dressing, the treatment method was identical for patients in both groups. The wound healing outcomes of the 2 groups were compared. Complete wound healing occurred in 87 patients (63.5%) in the polyurethane foam dressing group and in 28 patients (39.4%) in the control group within 12 weeks (P < .05, X test). The mean percentage of wound area reduction in both groups was statistically significant (P < .05, Mann-Whitney U test). The mean time required for complete closure in patients who achieved complete healing within 12 weeks was 6.2 (SD, 3.4) weeks and 7.3 (SD, 2.6) weeks in the polyurethane foam dressing and control groups, respectively (P < .05, Mann-Whitney U test). These results indicate that the highly hydrophilic polyurethane foam dressing may provide an effective treatment strategy for diabetic foot ulcers.
NASA Astrophysics Data System (ADS)
Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Lazǎr, Veronica; Chifiriuc, Mariana Carmen
2012-12-01
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.
2012-01-01
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues. PMID:23272823
Anghel, Ion; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Andronescu, Ecaterina; Ficai, Anton; Anghel, Alina Georgiana; Maganu, Maria; Laz R, Veronica; Chifiriuc, Mariana Carmen
2012-12-31
This paper reports a newly fabricated nanophyto-modified wound dressing with microbicidal and anti-adherence properties. Nanofluid-based magnetite doped with eugenol or limonene was used to fabricate modified wound dressings. Nanostructure coated materials were characterized by TEM, XRD, and FT-IR. For the quantitative measurement of biofilm-embedded microbial cells, a culture-based method for viable cell count was used. The optimized textile dressing samples proved to be more resistant to staphylococcal and pseudomonal colonization and biofilm formation compared to the uncoated controls. The functionalized surfaces for wound dressing seems to be a very useful tool for the prevention of wound microbial contamination on viable tissues.
Exploratory Development of an Ultrafast-Curing Wound Dressing
1991-05-31
mils thick: Formulation 2 and 5 .. 36 17. Elution Rates for the 30% Chlorhexidine Gluconate ADD’s at t=0 and Stored at the Temperature Extremes (400C...determined from the in vivo trials conducted earlier (9). The 6 mil thick dressing (Formulation 2) demonstrated effectiveness when tested on guinea pigs...This dressing released approximately 3000 micrograms/sq. cm. in 72 hours or about 64% of the 12 mil dressing tested for shelf stability (Figure 16
Woo, Kevin Y
2015-07-01
The purpose of this study was to examine the mediating effect of anxiety in the relationship between anticipation and pain in people with chronic wounds. Pain is common in people with chronic wounds. Anticipation or negative expectation of discomfort has been shown to have an augmenting effect on pain; also known as nocebo hyperalgesia. This was a cross-sectional study with repeated measures. Prior to dressing change, anticipatory pain level was evaluated by a 11-point numerical rating scale and anxiety by the Six-items State-Trait Anxiety Inventory (STAI-6). During wound dressing changes, pain was measured before dressing removal, at dressing removal, at cleansing and dressing application using the numerical scale. Analysis was completed based on the data from a convenience sample of 96 patients. Participants reported more pain at cleansing and dressing removal than baseline. High levels of anticipation, anxiety and pain at dressing change for wounds were related to heavy exudate and wound that were covered with necrotic tissue. Finally, the relationship between anticipation and pain perception was mediated by anxiety. Anticipation of pain triggers anxiety that can lead to increased pain. There is a need to incorporate evaluation of anxiety and personal expectations as part of comprehensive pain assessment. Clinicians should be aware of the impact of emotions and anticipation on overall pain experience. © 2015 John Wiley & Sons Ltd.
Ng, Shiow-Fern; Lew, Pit-Chin; Sin, Yong-Boey
2014-11-01
Topical emollients are known to provide symptomatic relief for atopic dermatitis. In hospitals, wet-wrap therapy has been shown to benefit children with moderate-to-severe atopic dermatitis (AD), but the application of wet-wraps is tedious and time-consuming. Topical emollients have low residence time and often dry out easily. The aim of this work was to develop a hydrogel-gauze dressing that is not only easy to apply but also rehydrates and traps moisture to provide longer relief for AD patients. In this study, a prototype hydrogel-gauze dressing was developed with varying ratios of sodium carboxymethylcellulose (NaCMC) and propylene glycol. The hydrogel-gauze dressings were assessed based on the moisture vapor transmission rate, moisture absorption, mechanical properties and storage stability over three months. Then, the efficacy of the hydrogel-gauze dressing was compared to topical emollients using transgenic NC/Nga mice with AD-like lesions. The NaCMC hydrogel-gauze dressings significantly lowered transepidermal water loss, and the animals displayed a faster recovery, which indicates that hydrogel-gauze dressings can trap moisture more effectively and accelerate AD healing. Hence, we propose that hydrogel-gauze dressings can potentially become an alternative to wet-wrap therapy due to the ease of application and the higher efficacy compared to topical products.
Gerçeker, Gülçin Özalp; Yardımcı, Figen; Aydınok, Yeşim
2017-06-01
To compare the effects of the care bundles including chlorhexidine dressing and advanced dressings on the catheter-related bloodstream infection (CRBSI) rates in pediatric hematology-oncology patients with central venous catheters (CVCs). Twenty-seven PHO patients were recruited to participate in a prospective, randomized study in Turkey. The researcher used care bundles with chlorhexidine dressing in the experimental group (n = 14), and care bundles with advanced dressings in the control group (n = 13). According to the study results, 28.6% of the patients in the experimental group had CRBSI, while this rate was 38.5% in the control group patients. The CRBSI rate in the experimental group was 3.9, and the control group had 4.4 per 1000 inpatient catheter days. There was no exit-site infection in the experimental group. However, the control group had 1.7 per 1000 inpatient catheter days. Even though there was no difference between the two groups in which the researcher implemented care bundles with chlorhexidine dressing and advanced dressings in terms of CRBSI development, there was reduction in the CRBSI rates thanks to the care bundle approach. It is possible to control the CRBSI rates using care bundles in pediatric hematology-oncology patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz
2015-08-12
The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used.
Witkowski, Wojciech; Surowiecka-Pastewka, Agnieszka; Biesaga, Magdalena; Gierczak, Tomasz
2015-01-01
Background The aim of this study was to determine effectiveness of first aid dressings in extinguishing burning white phosphorous (WP), eliminating WP pieces from the surface, inhibiting re-ignition on the model (fresh bacon covered with military uniform), and preventing from late re-ignition caused by persistent WP pieces. Material/Methods Burning WP was extinguished with several dressings: tactical Military Dressing (WJ10), wet gauze, 2 hydrocolloids, and 3 prototypes of hydrocolloids developed by the authors. Results All examined dressings were effective in extinguishing WP provided that the entire area of the burning substance was completely covered. Moist gauze was especially effective in extinguishing WP, and also removed and absorbed the majority of the WP mass, preventing deeper penetration of WP particles. The immediate re-ignition was observed when all the remaining examined dressings were removed from the bacon. A stream of water was dangerous, as it splashed and transferred pieces of WP around. Conclusions Moist gauze placed on burning WP for approximately 3 min was most effective in extinguishing WP and removing most of the WP pieces. We recommend moist gauze, used once or twice, as the best primary means for WP elimination and preventing tissue penetration. As a dressing used for medical evacuation (MEDEVAC), or as a second step after complete removal of visible WP, innovative hydrocolloid or hydrogel dressings should be used. PMID:26264209
Suzuki, Makoto; Yamada, Sumio; Omori, Mikayo; Hatakeyama, Mayumi; Sugimura, Yuko; Matsushita, Kazuhiko; Tagawa, Yoshikatsu
2008-09-01
A patient with poststroke hemiparesis learns to use the nonparetic arm to compensate for the weakness of the paretic arm to achieve independence in dressing. This is the learning process of new component actions on dressing. The purpose of this study was to develop the Upper-Body Dressing Scale (UBDS) for buttoned shirt dressing, which evaluates the component actions of upper-body dressing, and to provide preliminary data on internal consistency of the UBDS, as well as its reproducibility, validity, and sensitivity to clinical change. Correlational study of concurrent validity and reliability in which 63 consecutive stroke patients were enrolled in the study and were assessed repeatedly by the UBDS and the dressing item of Functional Independent Measure (FIM). Fifty-one patients completed the 3-wk study. The Cronbach's coefficient alpha of UBDS was 0.88. The principal component analysis extracted two components, which explained 62.3% of total variance. All items of the scale had high loading on the first component (0.65-0.83). Actions on the paralytic side were the positive loadings and actions on the healthy side were the negative loadings on the second component. Intraclass correlation coefficient was 0.87. The level of correlation between UBDS score and FIM dressing item scores was -0.72. Logistic regression analysis showed that only the score of UBDS on the first day of evaluation was a significant independent predictor of dressing ability (odds ratio, 0.82; 95% confidence interval, 0.71-0.95). The UBDS scores for paralytic hand passed into the sleeve, sleeve pulled up beyond the elbow joint, and sleeve pulled up beyond the shoulder joint were worse than the score for the other components of the task. These component actions had positive loading on the second component, which was identified by the principal component analysis. The UBDS has good internal consistency, reproducibility, validity, and sensitivity to clinical changes of patients with poststroke hemiparesis. This detailed UBDS assessment enables us to document the most difficult stages in dressing and to assess motor and process skills for independence of dressing.
8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...
8. SIDE VIEW OF NORTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (LEFT) AND DRESSED, DRY-LAID RETAINING WALL (RIGHT). FACING WEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA
10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE ...
10. SIDE VIEW OF SOUTHEASTERN ROCKFACED DRESSED AND MORTARED STONE BRIDGE ABUTMENT (RIGHT) AND DRESSED, DRY-LAID RETAINING WALL (LEFT). FACING NORTHWEST. - Coverts Crossing Bridge, Spanning Mahoning River along Township Route 372 (Covert Road), New Castle, Lawrence County, PA
NASA Astrophysics Data System (ADS)
Di Stefano, Omar; Stassi, Roberto; Garziano, Luigi; Frisk Kockum, Anton; Savasta, Salvatore; Nori, Franco
2017-05-01
In quantum field theory, bare particles are dressed by a cloud of virtual particles to form physical particles. The virtual particles affect properties such as the mass and charge of the physical particles, and it is only these modified properties that can be measured in experiments, not the properties of the bare particles. The influence of virtual particles is prominent in the ultrastrong-coupling regime of cavity quantum electrodynamics (QED), which has recently been realised in several condensed-matter systems. In some of these systems, the effective interaction between atom-like transitions and the cavity photons can be switched on or off by external control pulses. This offers unprecedented possibilities for exploring quantum vacuum fluctuations and the relation between physical and bare particles. We consider a single three-level quantum system coupled to an optical resonator. Here we show that, by applying external electromagnetic pulses of suitable amplitude and frequency, each virtual photon dressing a physical excitation in cavity-QED systems can be converted into a physical observable photon, and back again. In this way, the hidden relationship between the bare and the physical excitations can be unravelled and becomes experimentally testable. The conversion between virtual and physical photons can be clearly pictured using Feynman diagrams with cut loops.
Bhatta, Madhav; Regassa, Teshome; Rose, Devin J; Baenziger, P Stephen; Eskridge, Kent M; Santra, Dipak K; Poudel, Rachana
2017-12-01
Fine-tuning production inputs such as seeding rate, nitrogen (N), and genotype may improve end-use quality of hard red winter wheat (Triticum aestivium L.) when growing conditions are unpredictable. Studies were conducted at the Agronomy Research Farm (ARF; Lincoln, NE, USA) and the High Plains Agricultural Laboratory (HPAL; Sidney, NE, USA) in 2014 and 2015 in Nebraska, USA, to determine the effects of genotype (6), environment (4), seeding rate (3), and flag leaf top-dressed N (0 and 34 kg N ha -1 ) on the end-use quality of winter wheat. End-use quality traits were influenced by environment, genotype, seeding rate, top-dressed N, and their interactions. Mixograph parameters had a strong correlation with grain volume weight and flour yield. Doubling the recommended seeding rate and N at the flag leaf stage increased grain protein content by 8.1% in 2014 and 1.5% in 2015 at ARF and 4.2% in 2014 and 8.4% in 2015 at HPAL. The key finding of this research is that increasing seeding rates up to double the current recommendations with N at the flag leaf stage improved most of the end-use quality traits. This will have a significant effect on the premium for protein a farmer could receive when marketing wheat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Junka, Adam F; Żywicka, Anna; Szymczyk, Patrycja; Dziadas, Mariusz; Bartoszewicz, Marzena; Fijałkowski, Karol
2017-12-01
In the present article, we propose a simple Antibiofilm Dressing's Activity Measurement (A.D.A.M.) test that allows to check in vitro a dressing's suitability against biofilm-related wound infections. To perform the test, three agar discs are covered with biofilm formed by the tested pathogen after which they are assembled one over another in the form of an agar plug and placed in the well of a 24-well plate. The top disc is covered with the analyzed dressing and the entire set is incubated for 24h. During this time, the investigated antimicrobial substance is released from the dressing and penetrates to subsequent biofilm-covered agar discs. Biofilm reduction is measured using 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) spectrometric assay and the results are compared to untreated control samples (agar plug covered with biofilm and without the dressing/or with a passive dressing placed on the top disc). Furthermore, in order to standardize the differences in penetrability of the drugs released from active dressings the results can be expressed as a dimensionless value referred to as the Penetrability Index. In summary, A.D.A.M. test is simple, cheap, can be performed practically in every clinical laboratory and takes no more time than routine microbiological diagnostics. Apart from measuring the released drug's activity, the A.D.A.M. test allows to assess drug penetrability (across three agar discs), reflecting real wound conditions, where microbes are frequently hidden under the necrotic tissue or cloth. In conclusion, the A.D.A.M. test produces a high volume of data that, when analyzed, can provide a researcher with a valuable hint concerning the applicability of active dressings against specific biofilm pathogens in a particular setting. Copyright © 2017 Elsevier B.V. All rights reserved.
Lo, Shu-Fen; Chang, Chee-Jen; Hu, Wen-Yu; Hayter, Mark; Chang, Yu-Ting
2009-03-01
The purpose of this study was to examine the efficacy of silver-releasing dressings in the management of non-healing chronic wounds. Non-healing chronic wounds often have a negative physical impact on patients and place a financial burden on healthcare systems. Silver dressings are wound products designed to control infection and provide a wound environment conducive to healing. However, validation of the clinical efficacy of these dressings is lacking. Systematic review and meta-analysis. A systematic search of the major electronic databases PubMed, CINAHL, Cochrane, MEDLINE, British Nursing Index, EBSCO, OCLC and Proquest between 1950-June 2007 was conducted. Hand searches of selected periodicals, textbooks and checking reference lists and contacting experts was also performed. Eight studies were selected from a potentially relevant 1957 references screened. Analysis incorporated data from 1399 participants in the eight randomised control trials. We found that silver dressings significantly improved wound healing (CI(95): 0.16-0.39, p < 0.001), reduced odour (CI(95): 0.24-0.52, p < 0.001) and pain-related symptoms (CI(95): 0.18-0.47, p < 0.001), decreased wound exudates (CI(95): 0.17-0.44, p < 0.001) and had a prolonged dressing wear time (CI(95): 0.19-0.48, p = 0.028) when compared with alternative wound management approaches. An analysis of sensitivity in these studies by subgroup analysis generally supported these associations. Furthermore, studies indicated an improvement in quality of life (CI(95): 0.04-0.33, p = 0.013) using silver dressings in wound management with no associated severe adverse events. This meta-analysis confirms the effectiveness of silver dressings in wound healing and improving patients' quality of life. However, it also highlights the need for additional well-designed randomised controlled trials to evaluate the effectiveness of silver-related dressings further. The results of this study provide objective data on the effectiveness of silver-related dressing when applied to non-healing chronic wounds.
NASA Astrophysics Data System (ADS)
Chen, Mingjun; Li, Ziang; Yu, Bo; Peng, Hui; Fang, Zhen
2013-09-01
In the grinding of high quality fused silica parts with complex surface or structure using ball-headed metal bonded diamond wheel with small diameter, the existing dressing methods are not suitable to dress the ball-headed diamond wheel precisely due to that they are either on-line in process dressing which may causes collision problem or without consideration for the effects of the tool setting error and electrode wear. An on-machine precision preparation and dressing method is proposed for ball-headed diamond wheel based on electrical discharge machining. By using this method the cylindrical diamond wheel with small diameter is manufactured to hemispherical-headed form. The obtained ball-headed diamond wheel is dressed after several grinding passes to recover geometrical accuracy and sharpness which is lost due to the wheel wear. A tool setting method based on high precision optical system is presented to reduce the wheel center setting error and dimension error. The effect of electrode tool wear is investigated by electrical dressing experiments, and the electrode tool wear compensation model is established based on the experimental results which show that the value of wear ratio coefficient K' tends to be constant with the increasing of the feed length of electrode and the mean value of K' is 0.156. Grinding experiments of fused silica are carried out on a test bench to evaluate the performance of the preparation and dressing method. The experimental results show that the surface roughness of the finished workpiece is 0.03 μm. The effect of the grinding parameter and dressing frequency on the surface roughness is investigated based on the measurement results of the surface roughness. This research provides an on-machine preparation and dressing method for ball-headed metal bonded diamond wheel used in the grinding of fused silica, which provides a solution to the tool setting method and the effect of electrode tool wear.
Zhou, Xin; Wang, He; Zhang, Jimin; Li, Xuemei; Wu, Yifan; Wei, Yongzhen; Ji, Shenglu; Kong, Deling; Zhao, Qiang
2017-05-01
Wound healing dressings are increasingly needed clinically due to the large number of skin damage annually. Nitric oxide (NO) plays a key role in promoting wound healing, thus biomaterials with NO-releasing property receive increasing attention as ideal wound dressing. In present study, we prepared a novel functional wound dressing by combining electrospun poly(ε-caprolactone) (PCL) nonwoven mat with chitosan-based NO-releasing biomaterials (CS-NO). As-prepared PCL/CS-NO dressing released NO sustainably under the physiological conditions, which was controlled by the catalysis of β-galactosidase. In vivo wound healing characteristics were further evaluated on full-thickness cutaneous wounds in mice. Results showed that PCL/CS-NO wound dressings remarkably accelerated wound healing process through enhancing re-epithelialization and granulation formation and effectively improved the organization of regenerated tissues including epidermal-dermal junction, which could be ascribed to the pro-angiogenesis, immunomodulation, and enhanced collagen synthesis provided by the sustained release of NO. Therefore, PCL/CS-NO may be a promising candidate for wound dressings, especially for the chronic wound caused by the ischemia. Serious skin damage caused by trauma, surgery, burn or chronic disease has become one of the most serious clinical problems. Therefore, there is an increasing demand for ideal wound dressing that can improve wound healing. Due to the vital role of nitric oxide (NO), we developed a novel functional wound dressing by combining electrospun polycaprolactone (PCL) mat with NO-releasing biomaterial (CS-NO). The sustained release of NO from PCL/CS-NO demonstrated positive effects on wound healing, including pro-angiogenesis, immunomodulation, and enhanced collagen synthesis. Hence, wound healing process was remarkably accelerated and the organization of regenerated tissues was effectively improved as well. Taken together, PCL/CS-NO dressing may be a promising candidate for wound treatment, especially for the chronic wound caused by the ischemia. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Biophysical effects of repetitive removal of adhesive dressings on peri-ulcer skin.
Zillmer, R; Agren, M S; Gottrup, F; Karlsmark, T
2006-05-01
To study the effect of repeated removal of four different adhesive dressings on peri-ulcer skin using quantitative non-invasive techniques. Forty-five patients with open (n = 29) or healed (n = 16) venous leg ulcers were included. Peri-ulcer skin was treated for 14 days with patches of two different hydrocolloid-based adhesive dressings, one polyurethane adhesive and one soft silicone adhesive dressing. Normal skin of the patients' ventral forearm was also treated identically. Adhesive patches of the dressings were replaced every second day. The skin barrier function was assessed by measuring transepidermal water loss and stratum corneum hydration by measuring electrical conductance. Thirty-nine patients completed the study. The hydrocolloid adhesives increased transepidermal water loss and conductance while the polyurethane and soft silicone adhesives did not influence these parameters significantly compared with adjacent non-treated peri-ulcer skin. For normal forearm skin, similar relative effects among the four adhesives were found. Repetitive treatment with hydrocolloid-based adhesive dressings induced major functional alterations of the stratum corneum. In contrast, a polyurethane adhesive and a soft silicone adhesive dressing did not alter transepidermal water loss or conductance of peri-ulcer skin.
Misgav, Mudi; Kenet, Gili; Martinowitz, Uriel
2014-03-01
Bleeding episodes in patients with congenital or acquired bleeding disorders are usually managed with factor concentrates or blood products. However, external and accessible bleeds may effectively be managed with topical hemostasis. After the application of the Hemcon, a Food and Drug Administration-approved chitosan-based hemostatic dressing was used as the "last resort" to successfully control external bleeds in 2 patients with severe bleeding disorders. We describe a single-center experience with this dressing, including its use in pediatric patients as the first mode of therapy. A total of 5 patients (median age 2 y) with severe bleeding disorders were treated with topical chitosan-based dressing for a total of 6 bleeding episodes. The dressing was used either after the failure of extensive systemic therapy or as the first choice of treatment. In 4 of the 6 episodes, bleeding ceased immediately alleviating the need for systemic therapy. There was no rebleeding after the removal of the dressing and no adverse events or local skin reactions were recorded. Hemostatic dressings, such as the chitosan, should be encouraged for the treatment of external/accessible bleeds, especially among the pediatric patients with bleeding tendency.
Topical Application of Honey on Surgical Wounds: A Randomized Clinical Trial.
Goharshenasan, Peiman; Amini, Shahideh; Atria, Ali; Abtahi, Hamidreza; Khorasani, Ghasemali
2016-01-01
The antimicrobial and anti-inflammatory activity of honey and its ability to accelerate wound healing make it an attractive option in surgical wound care. We performed a randomized clinical trial to compare the efficacy of honey dressing with conventional dressing regarding the aesthetic outcome. Bilateral symmetric incisions in randomly selected plastic surgical patients were randomly covered postoperatively with conventional dressing and honey dressing for five days. The aesthetic outcome of the two sides was rated on a Visual Analog Scale by the surgeon and the patient and compared at month three and six after surgery. Seventy two symmetrical incisions in 52 patients were evaluated during the study. The mean width of the scar after the third and the sixth month was 3.64 +/- 0.83 mm and 3.49 +/- 0.87 mm on the side that received honey dressing and 5.43 +/- 0.05 mm and 5.30+/- 1.35 mm in the control group. Wilcoxon signed-rank test showed significant difference between honey and conventional dressing outcomes at third and sixth month (p < 0.001). The healing process of the surgical wound and its final aesthetic result could be improved by using honey dressing. © 2016 S. Karger GmbH, Freiburg.
Aduba, Donald C.; Yang, Hu
2017-01-01
Wound dressings are critical for wound care because they provide a physical barrier between the injury site and outside environment, preventing further damage or infection. Wound dressings also manage and even encourage the wound healing process for proper recovery. Polysaccharide biopolymers are slowly becoming popular as modern wound dressings materials because they are naturally derived, highly abundant, inexpensive, absorbent, non-toxic and non-immunogenic. Polysaccharide biopolymers have also been processed into biomimetic platforms that offer a bioactive component in wound dressings that aid the healing process. This review primarily focuses on the fabrication and biocompatibility assessment of polysaccharide materials. Specifically, fabrication platforms such as electrospun fibers and hydrogels, their fabrication considerations and popular polysaccharides such as chitosan, alginate, and hyaluronic acid among emerging options such as arabinoxylan are discussed. A survey of biocompatibility and bioactive molecule release studies, leveraging polysaccharide’s naturally derived properties, is highlighted in the text, while challenges and future directions for wound dressing development using emerging fabrication techniques such as 3D bioprinting are outlined in the conclusion. This paper aims to encourage further investigation and open up new, disruptive avenues for polysaccharides in wound dressing material development. PMID:28952482
Advanced textile materials and biopolymers in wound management.
Petrulyte, Salvinija
2008-02-01
New generation medical textiles are an important growing field with great expansion in wound management products. Virtually new products are coming but also well known materials with significantly improved properties using advanced technologies and new methods are in the centre of research which are highly technical, technological, functional, and effective oriented. The key qualities of fibres and dressings as wound care products include that they are bacteriostatic, anti-viral, fungistatic, non-toxic, high absorbent, non-allergic, breathable, haemostatic, biocompatible, and manipulatable to incorporate medications, also provide reasonable mechanical properties. Many advantages over traditional materials have products modified or blended with also based on alginate, chitin/chitosan, collagen, branan ferulate, carbon fibres. Textile structures used for modern wound dressings are of large variety: sliver, yarn, woven, non-woven, knitted, crochet, braided, embroidered, composite materials. Wound care also applies to materials like hydrogels, matrix (tissue engineering), films, hydrocolloids, foams. Specialized additives with special functions can be introduced in advanced wound dressings with the aim to absorb odours, provide strong antibacterial properties, smooth pain and relieve irritation. Because of unique properties as high surface area to volume ratio, film thinness, nano scale fibre diameter, porosity, light weight, nanofibres are used in wound care. The aim of this study is to outline and review the latest developments and advance in medical textiles and biopolymers for wound management providing the overview with generalized scope about novelties in products and properties.
Aramwit, Pornanong; Yamdech, Rungnapha; Ampawong, Sumate
2016-05-01
One approach in wound dressing development is to incorporate active molecules or drugs in the dressing. In order to reduce the frequency of dressing changes as well as to prolong wound healing efficacy, wound dressings that can sustain the release of the active molecules should be developed. In our previous work, we developed chitosan/sericin (CH/SS) microspheres that released sericin in a controlled rate. However, the difficulty of applying the microspheres that easily diffuse and quickly degrade onto the wound was its limitations. In this study, we aimed to develop wound dressing materials which are easier to apply and to provide extended release of sericin. Different amounts of CH/SS microspheres were embedded into various compositions of polyvinyl alcohol/gelatin (PVA/G) scaffolds and fabricated using freeze-drying and glutaraldehyde crosslinking techniques. The obtained CH/SS microspheres-embedded scaffolds with appropriate design and formulation were introduced as a wound dressing material. Sericin was released from the microspheres and the scaffolds in a sustained manner. Furthermore, an optimized formation of the microspheres-embedded scaffolds (2PVA2G+2CHSS) was shown to possess an effective antimicrobial activity against both gram-positive and gram-negative bacteria. These microspheres-embedded scaffolds were not toxic to L929 mouse fibroblast cells, and they did not irritate the tissue when applied to the wound. Finally, probably by the sustained release of sericin, these microspheres-embedded scaffolds could promote wound healing as well as or slightly better than a clinically used wound dressing (Allevyn®) in a mouse model. The antimicrobial CH/SS microspheres-embedded PVA/G scaffolds with sustained release of sericin would appear to be a promising candidate for wound dressing application.
Assadian, Ojan; Arnoldo, Brett; Purdue, Gary; Burris, Agnes; Skrinjar, Edda; Duschek, Nikolaus; Leaper, David J
2015-06-01
This prospective, randomised study compares a new transforming methacrylate dressing (TMD) with a silver-containing carboxymethylcellulose dressing (CMC-Ag) after application to split-thickness skin graft (STSG) donor sites. This was an unblinded, non-inferiority, between-patient, comparison study that involved patients admitted to a single-centre burn unit who required two skin graft donor sites. Each patient's donor sites were covered immediately after surgery: one donor site with TMD and the other with CMC-Ag. The donor sites were evaluated until healing or until 24 days post-application, whichever came first. Study endpoints were time to healing, daily pain scores, number of dressing changes, patient comfort and physicians' and patients' willingness to use the dressings in the future. Nineteen patients had both the dressings applied. No statistically significant difference was noted in time to healing between the two dressings (14·2 days using TMD compared with 13·2 days using CMC-Ag). When pain scores were compared, TMD resulted in statistically significantly less pain at three different time periods (2-5 days, 6-10 days and 11-15 days; P < 0·001 at all time periods). Patients also reported greater comfort with TMD (P < 0·001). Users rated TMD as being less easy to use because of the time and technique required for application. Reductions in pain and increased patient comfort with the use of the TMD dressing, compared with CMC-Ag, were seen as clinical benefits as these are the major issues in donor site management. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Wang, Li; Li, Lin-Feng
2017-03-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome is a severe drug-induced hypersensitivity reaction characterized by skin rash, fever, blood abnormalities, and multiple organ involvement. The diagnosis of DRESS syndrome is often delayed because of its variable presentation. Prompt withdrawal of the culprit drug is the definitive treatment. DRESS syndrome induced by antituberculosis drugs has rarely been reported. A 50-year-old man admitted to our hospital with recurrent episodes of progressive rash, fever, eosinophilia, lymphadenopathy, hepatic, and pulmonary involvement were experienced after repeat trials of the same antituberculosis drugs. We diagnosed it as DRESS caused by antituberculosis drugs. The case responded well to treatment with systemic corticosteroids and intravenous immunoglobulins. However, repeated bouts of infection with methicillin-resistant Staphylococcus aureus occurred during treatment (clavicular osteomyelitis and knee septic arthritis). He was cured after treatment with linezolid. The patient was discharged on day 112. At 8-month follow-up, there was no relapse of drug eruption and joint swelling. Early diagnosis and prompt withdrawal of all suspected drugs is a key tenet of the treatment of DRESS. Our case report highlights the risks inherent in delayed diagnosis of DRESS and the challenges in the clinical management of this condition. Pulmonary manifestations with radiological changes on chest X-ray and CT can be seen in DRESS. These changes need to be differentiated from those caused by pulmonary infections. Clavicular osteomyelitis infected with MRSA may be caused by iatrogenic injury during subclavian vein catheterization. This type of MRSA infections should be treated for 4 to 6 weeks. Blood eosinophilia could be a useful marker of disease progression and treatment response in patients with DRESS. However, more experience and clinical evidence is needed to confirm this.
Nakagami, Gojiro; Sanada, Hiromi; Konya, Chizuko; Kitagawa, Atsuko; Tadaka, Etsuko; Matsuyama, Yutaka
2007-09-01
This paper is a report of an evaluation of the effectiveness of a newly developed dressing for preventing persistent erythema and pressure ulcer development and improving the water-holding capacity without increasing the skin pH in bedridden older patients. Shear forces and skin dryness play important roles in persistent erythema and pressure ulcer development. To eliminate these risks, we developed a dressing to reduce shear forces and improve the water-holding capacity. However, the effects of this dressing in clinical settings remain unknown. An experimental bilateral comparison study was conducted at a hospital in Japan in 2004 with 37 bedridden older patients at risk of pressure ulcer development. The dressing was randomly applied to the right or left greater trochanter for 3 weeks. No dressing was applied to the opposite side as a control. The skin was monitored weekly during the 3-week application for persistent erythema and pressure ulcer development. Skin hydration and pH were also assessed during the intervention and for 1 week after dressing removal. The incidence of persistent erythema was significantly lower in the intervention area than the control area [P = 0.007, RR 0.18 (95% CI: 0.05-0.73) and NNT 4.11 (2.50-11.63) ]. No pressure ulcers occurred in either the intervention or control area. Skin hydration increased significantly during dressing application and remained high after removal (P < 0.001) relative to the control area. Skin pH decreased significantly during the application (P < 0.001) but returned to control levels after removal (P = 0.38). This safe and effective dressing can be used for patients with highly prominent bones and dry skin to prevent pressure ulcers.
Patients' attitudes toward the attire of male physicians: a single-center study in Saudi Arabia.
Batais, Mohammad Ali
2014-01-01
The doctor-patient relationship has been influenced by the appearance of physicians, and there is an association between a physician's physical appearance and the patients' initial perceptions of physician competence. This study aims to explore patients' preferences toward the attire of a male physician, and to examine if a physician's choice of uniform influences the degree of trust, confidence, and follow-up care among respondents. A cross-sectional survey conducted among patients of the Alwazarat family medicine center in Riyadh, Saudi Arabia. A self-administered questionnaire was completed by 300 patients (50% were male and 83.6% had received a secondary education; the mean age was 33.4 [10.1] years) in the Alwazarat family medicine center in Riyadh. The questionnaire was also customized for the local setting with the inclusion of photos of a male doctor in Saudi Arabian national costume, and 3 other dress styles (Western dress with white coat, scrubs with white coat, and scrubs only). Overall, across all questions regarding physician dress style preferences, participants significantly preferred Western dress (39.9%, P < .001), followed by Saudi national dress (26.3%), a scrub suit with a white coat (22.3%), and scrubs only (11.5%). Respondents reported that they were more likely to follow medical advice and would return for follow-up care if a physician wore Western dress. They were significantly more willing to share their social, sexual, and psychological problems with a physician wearing Saudi national dress (P < .001). The importance of a physician's appearance was ranked significantly higher by older patients (P=.002). Respondents were more likely to favor a physician wearing Western attire with a white coat. However, Saudi national dress, followed by Western dress, is the preferred attire when physicians are dealing with social, sexual, and psychological problems.
Chin, Chai-Yee; Jalil, Juriyati; Ng, Pei Yuen; Ng, Shiow-Fern
2018-02-15
M.oleifera is a medicinal plant traditionally used for skin sores, sore throat and eye infections. Recently, the wound healing property of the leaves of M. oleifera was has been well demonstrated experimentally in both in vivo and in vitro models. However, there is a lack of research which focuses on formulating M.oleifera into a functional wound dressing. In this study, the M.oleifera leaf standardized aqueous extract with highest potency in vitro migration was formulated into a film for wound healing application. Firstly, M. oleifera leaf were extracted in various solvents (aqueous, 50%, 70% and 100% ethanolic extracts) and standardized by reference standards using UHPLC technique. The extracts were then tested for cell migration and proliferation using HDF and HEK cell lines. M. oleifera leaf aqueous extract was then incorporated into alginate-pectin (SA-PC) based film dressing. The film dressings were characterized for the physicochemical properties and the bioactives release from the M. oleifera leaf extract loaded film dressing was also investigated using Franz diffusion cells. All extracts were found to contain vicenin-2, chlorogenic acid, gallic acid, quercetin, kaempferol, rosmarinic acid and rutin. Among all M. oleifera extracts, aqueous standardized leaf extracts showed the highest human dermal fibroblast and human keratinocytes cells proliferation and migration properties. Among the film formulations, SA-PC (3% w/v) composite film dressing containing M. oleifera aqueous leaf extract was found to possess optimal physicochemical properties as wound dressing. A potentially applicable wound dressing formulated as an alginate-pectin film containing aqueous extracts of M. oleifera has been developed. The dressing would be suitable for wounds with moderate exudates. Copyright © 2017 Elsevier B.V. All rights reserved.
Biffi, Roberto; Fattori, Luca; Bertani, Emilio; Radice, Davide; Rotmensz, Nicole; Misitano, Pasquale; Cenciarelli, Sabine; Chiappa, Antonio; Tadini, Liliana; Mancini, Marina; Pesenti, Giovanni; Andreoni, Bruno; Nespoli, Angelo
2012-05-23
An antimicrobial dressing containing ionic silver was found effective in reducing surgical-site infection in a preliminary study of colorectal cancer elective surgery. We decided to test this finding in a randomized, double-blind trial. Adults undergoing elective colorectal cancer surgery at two university-affiliated hospitals were randomly assigned to have the surgical incision dressed with Aquacel Ag Hydrofiber dressing or a common dressing. To blind the patient and the nursing and medical staff to the nature of the dressing used, scrub nurses covered Aquacel Ag Hydrofiber with a common wound dressing in the experimental arm, whereas a double common dressing was applied to patients of control group. The primary end-point of the study was the occurrence of any surgical-site infection within 30 days of surgery. A total of 112 patients (58 in the experimental arm and 54 in the control group) qualified for primary end-point analysis. The characteristics of the patient population and their surgical procedures were similar. The overall rate of surgical-site infection was lower in the experimental group (11.1% center 1, 17.5% center 2; overall 15.5%) than in controls (14.3% center 1, 24.2% center 2, overall 20.4%), but the observed difference was not statistically significant (P = 0.451), even with respect to surgical-site infection grade 1 (superficial) versus grades 2 and 3, or grade 1 and 2 versus grade 3. This randomized trial did not confirm a statistically significant superiority of Aquacel Ag Hydrofiber dressing in reducing surgical-site infection after elective colorectal cancer surgery. Clinicaltrials.gov: NCT00981110.
Payne, Caroline; Edwards, Daren
2014-01-01
Objectives: Traumatic wounds and surgery inherently have their complications. Localized infections, wound dehiscence, and excessive wound leakage can be devastating to the patient with a prolonged recovery, but it is also costly to the hospital with an increased length of stay, extra workload, and dressing changes. The single use PICO (Smith and Nephew Healthcare, Hull, United Kingdom) negative pressure wound therapy (NPWT) dressing has revolutionized our management of various acute, chronic, and high output wounds. It requires fewer dressing changes than conventional practice, is used in the outpatient setting, and is a necessary adjuvant therapy to hasten wound healing. Aims: To observe the efficacy of the PICO vacuum-assisted healing within a cost improvement programme. Settings: Plastic surgery department, Royal London Hospital. Materials and Methods: Twenty-one patients with a diversity of postoperative or posttraumatic wounds were considered suitable for PICO application and treated totally on an outpatient basis once the PICO dressing was applied. All wounds were then subjected to continued PICO dressings until healed. Results: All patients tolerated the PICO well with no dressing failure or failure to comply. The number of dressings per patient ranged from 1 to 7. The cost per patient of treatment ranged from £120 to £1578. Estimated cost of all PICO dressing for 21 patients including plastic surgery dressing clinic appointments = £13,345. Median length of treatment to healing (days) = 16; standard deviation = 9.5. Eight patients would have had an inpatient bed stay with conventional therapy, total 24 bed days saved at Bartshealth @£325 per day. Conclusions: The outpatient application of a disposable NPWT can benefit a wide range of clinical wounds that optimizes patient care, promotes rapid wound healing, and importantly helps manage costs. PMID:24917894
Devices and dressings to secure peripheral venous catheters to prevent complications.
Marsh, Nicole; Webster, Joan; Mihala, Gabor; Rickard, Claire M
2015-06-12
A peripheral venous catheter (PVC) is typically used for short-term delivery of intravascular fluids and medications. It is an essential element of modern medicine and the most frequent invasive procedure performed in hospitals. However, PVCs often fail before intravenous treatment is completed: this can occur because the device is not adequately attached to the skin, allowing the PVC to fall out, leading to complications such as phlebitis (irritation or inflammation to the vein wall), infiltration (fluid leaking into surrounding tissues) or occlusion (blockage). An inadequately secured PVC also increases the risk of catheter-related bloodstream infection (CRBSI), as the pistoning action (moving back and forth in the vein) of the catheter can allow migration of organisms along the catheter and into the bloodstream. Despite the many dressings and securement devices available, the impact of different securement techniques for increasing PVC dwell time is still unclear; there is a need to provide guidance for clinicians by reviewing current studies systematically. To assess the effects of PVC dressings and securement devices on the incidence of PVC failure. We searched the following electronic databases to identify reports of relevant randomised controlled trials (RCTs): the Cochrane Wounds Group Register (searched 08 April 2015): The Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (1946 to March 7 2015); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, March 7 2015); Ovid EMBASE (1974 to March 7 2015); and EBSCO CINAHL (1982 to March 8 2015). RCTs or cluster RCTs comparing different dressings or securement devices for the stabilisation of PVCs. Cross-over trials were ineligible for inclusion, unless data for the first treatment period could be obtained. Two review authors independently selected studies, assessed trial quality and extracted data. We contacted study authors for missing information. We used standard methodological procedures expected by Cochrane. We included six RCTs (1539 participants) in this review. Trial sizes ranged from 50 to 703 participants. These six trials made four comparisons, namely: transparent dressings versus gauze; bordered transparent dressings versus a securement device; bordered transparent dressings versus tape; and transparent dressing versus sticking plaster. There is very low quality evidence of fewer catheter dislodgements or accidental removals with transparent dressings compared with gauze (two studies, 278 participants, RR 0.40; 95% CI 0.17 to 0.92, P = 0.03%). The relative effects of transparent dressings and gauze on phlebitis (RR 0.89; 95% CI 0.47 to 1.68) and infiltration (RR 0.80; 95% CI 0.48 to 1.33) are unclear. The relative effects on PVC failure of a bordered transparent dressing and a securement device have been assessed in only one small study and these were unclear. There was very low quality evidence from the same single study of less frequent dislodgement or accidental catheter removal with bordered transparent dressings than securement devices (RR 0.14, 95% CI 0.03 to 0.63) but more phlebitis with bordered dressings (RR 8.11, 95% CI 1.03 to 64.02) (very low quality evidence). A small single study compared bordered transparent dressings with tape and found very low quality evidence of more PVC failure with the bordered dressing (RR 1.84, 95% CI 1.08 to 3.11) but the relative effects on dislodgement were not clear (very low quality evidence). The relative effects of transparent dressings and a sticking plaster have only been compared in one small study and are unclear. More high quality RCTs are required to determine the relative effects of alternative PVC dressings and securement devices. It is not clear if any one dressing or securement device is better than any other in securing peripheral venous catheters. There is a need for further, independent high quality trials to evaluate the many traditional as well as the newer, high use products. Given the large cost differences between some different dressings and securement devices, future trials should include a robust cost-effectiveness analysis.
González, Arturo
2016-01-01
This case study describes treatment for a 52-year-old man with a recurrent venous leg ulcer using a collagen dressing with extracellular matrix. The patient was admitted to the wound care service for a 3-week-old recurrent venous ulcer. Treatment included application of a collagen dressing with extracellular matrix twice weekly or as needed by the patient; application of a secondary dressing (4 × 4 gauze); and coverage with an expandable netting or gauze using a conforming stretch gauze bandage and latex-free dressing retention tape. The initial venous leg ulcer in this patient required 10 weeks to achieve closure. Ninety-eight percent resolution of the recurrent ulcer had occurred within 4 weeks of treatment, with complete closure at 7 weeks. The average healing time for recurrent venous ulcers is reported in the literature to be longer than initial venous ulcers. In the case provided, collagen ECM dressings promoted complete wound healing in 49 days.
Application of VitaVallis dressing for infected wounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirilova, N. V., E-mail: n.kirilova@vitavallis.com; Fomenko, A. N., E-mail: alserova@ispms.tsc.ru; Korovin, M. S., E-mail: msk@ispms.tsc.ru
Today there is a growing demand for safe and efficient antimicrobial dressings for infected wound treatment. The antimicrobial sorption material for VitaVallis dressings was produced by one-stage oxidation of aluminum nanopowder in water in the presence of fibrous acetylcellulose matrix. Scanning electron microscopy revealed that the material is made up of fibers of diameter 1.5–3.0 µm with adhered agglomerated alumina nanosheets. An antimicrobial study revealed a high inhibitory effect of VitaVallis against the growth of gram-negative (E.coli, P. aeruginosa) and gram-positive (S. aureus) strains. The antimicrobial activity of the dressing against microbial pathogens on the wound surface was demonstrated in inmore » vivo experiments on male rats. The dressing was also tested on volunteer patients. The testing showed reduction of the wound healing period, accelerated cleaning of the infected wound and enhanced tissue regeneration in the wound. The results demonstrate that the VitaVallis dressing can be used for the treatment of deep infected wounds.« less
Waring, Mike; Bielfeldt, Stephan; Mätzold, Katja; Wilhelm, Klaus-Peter
2013-02-01
Chronic wounds require frequent dressing changes. Adhesive dressings used for this indication can be damaging to the stratum corneum, particularly in the elderly where the skin tends to be thinner. Understanding the level of damage caused by dressing removal can aid dressing selection. This study used a novel methodology that applied a stain to the skin and measured the intensity of that stain after repeated application and removal of a series of different adhesive types. Additionally, a traditional method of measuring skin barrier damage (transepidermal water loss) was also undertaken and compared with the staining methodology. The staining methodology and measurement of transepidermal water loss differentiated the adhesive dressings, showing that silicone adhesives caused least trauma to the skin. The staining methodology was shown to be as effective as transepidermal water loss in detecting damage to the stratum corneum and was shown to detect disruption of the barrier earlier than the traditional technique. © 2012 John Wiley & Sons A/S.
Controlled trial of Iodosorb in chronic venous ulcers.
Ormiston, M C; Seymour, M T; Venn, G E; Cohen, R I; Fox, J A
1985-01-01
Cadexomer iodine (Iodosorb) is a hydrophilic starch powder containing iodine, which is a suitable dressing for granulating wounds such as venous ulcers. A total of 61 outpatients with chronic venous ulcers participated in a randomised optional crossover trial using cadexomer iodine or a standard dressing for their ulcers. The trial lasted for 24 weeks or until the ulcer had healed. Two patients withdrew during the course of the trial. Both treatments were highly effective, but the epithelium of ulcers dressed with cadexomer iodine grew again significantly faster (p less than 0.001). At the midpoint of the trial (12th week) 13 of 30 patients receiving standard treatment were changed to cadexomer iodine, while only three of 29 receiving cadexomer iodine changed to the standard dressing (p less than 0.02). In most cases ulcers were dressed and rebandaged daily by the patients themselves after instruction and supervision. This may be better than having dressings and bandages applied by professionals less regularly. PMID:3926169
Gelam (Melaleuca spp.) Honey-Based Hydrogel as Burn Wound Dressing
Mohd Zohdi, Rozaini; Abu Bakar Zakaria, Zuki; Yusof, Norimah; Mohamed Mustapha, Noordin; Abdullah, Muhammad Nazrul Hakim
2012-01-01
A novel cross-linked honey hydrogel dressing was developed by incorporating Malaysian honey into hydrogel dressing formulation, cross-linked and sterilized using electron beam irradiation (25 kGy). In this study, the physical properties of the prepared honey hydrogel and its wound healing efficacy on deep partial thickness burn wounds in rats were assessed. Skin samples were taken at 7, 14, 21, and 28 days after burn for histopathological and molecular evaluations. Application of honey hydrogel dressings significantly enhanced (P < 0.05) wound closure and accelerated the rate of re-epithelialization as compared to control hydrogel and OpSite film dressing. A significant decrease in inflammatory response was observed in honey hydrogel treated wounds as early as 7 days after burn (P < 0.05). Semiquantitative analysis using RT-PCR revealed that treatment with honey hydrogel significantly (P < 0.05) suppressed the expression of proinflammatory cytokines (IL-1α, IL-1β, and IL-6). The present study substantiates the potential efficacy of honey hydrogel dressings in accelerating burn wound healing. PMID:21941590
EL Omairi, Nissrine; Abourazzak, Sanae; Chaouki, Sanae; Atmani, Samir; Hida, Moustapha
2014-01-01
Drug-induced hypersensitivity or Drug Reaction with Eosinophilia and Systemic Symptom (DRESS) is a severe adverse drug-induced reaction. Diagnosing DRESS is challenging due to the diversity of cutaneous eruption and organs involved. Most of the aromatic anticonvulsants, such as phenytoin, phenobarbital, and carbamazepine, can induce DRESS. Culprit drug withdrawal and corticosteroids constituted the mainstay of DRESS treatment. We describe a 6 year-old boy who presented fever and rash 4 weeks after starting carbamazepine. Investigation revealed leukocytosis, atypical lymphocytosis, and elevated serum transaminases. The diagnosis of DREES syndrome was made, Carbamazepine was stopped and replaced initially by Clobazam and by Valproic acid after discharge, no systemic corticotherapy was prescribed. Symptoms began to resolve within two weeks, and by one month later her laboratory values had returned to normal. The aim of this work is to raise awareness general practitioner and pediatricians to suspect Dress syndrome in patients who present with unusual complaints and skin findings after starting any antiepileptic drug. PMID:25360193
Evaluation of a honey-impregnated tulle dressing in primary care.
Stephen-Haynes, Jackie
2004-06-01
Honey has been used for its healing properties for centuries and has been used to dress wounds with favourable results. The emergence of antibiotic resistance and growing interest in "natural" or "complementary" therapies has led to an interest in honey dressings. Much of the research to date has been related to honey's antibacterial properties. However, the healing properties claimed for honey also include stimulating new tissue growth, moist wound healing, fluid handling and promoting epithelialization. Until recently, honey had not been developed as a wound management product and was not a certified pharmaceutical device. Activon Tulle is a sterile, non-adherent dressing impregnated with Leptospermum scoparium hone. The claimed properties of honey dressings would make this a valuable addition to the dressing currently available in the primary care setting. An evaluation was undertaken involving 20 patients with a variety of wounds. A conclusion is drawn that while further research is needed, medical grade honey does appear to be a valuable addition to the wound management formulary.
Effects of wound dressings on cultured primary keratinocytes.
Esteban-Vives, Roger; Young, Matthew T; Ziembicki, Jenny; Corcos, Alain; Gerlach, Jörg C
2016-02-01
Autologous cell-spray grafting of non-cultured epidermal cells is an innovative approach for the treatment of severe second-degree burns. After treatment, wounds are covered with dressings that are widely used in wound care management; however, little is known about the effects of wound dressings on individually isolated cells. The sprayed cells have to actively attach, spread, proliferate, and migrate in the wound for successful re-epithelialization, during the healing process. It is expected that exposure to wound dressing material might interfere with cell survival, attachment, and expansion. Two experiments were performed to determine whether some dressing materials have a negative impact during the early phases of wound healing. In one experiment, freshly isolated cells were seeded and cultured for one week in combination with eight different wound dressings used during burn care. Cells, which were seeded and cultured with samples of Adaptic(®), Xeroform(®), EZ Derm(®), and Mepilex(®) did not attach, nor did they survive during the first week. Mepitel(®), N-Terface(®), Polyskin(®), and Biobrane(®) dressing samples had no negative effect on cell attachment and cell growth when compared to the controls. In a second experiment, the same dressings were exposed to pre-cultured cells in order to exclude the effects of attachment and spreading. The results confirm the above findings. This study could be of interest for establishing skin cell grafting therapies in burn medicine and also for wound care in general. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Efficacy of a surfactant-based wound dressing on biofilm control.
Percival, Steven L; Mayer, Dieter; Salisbury, Anne-Marie
2017-09-01
The aim of this study was to evaluate the efficacy of both a nonantimicrobial and antimicrobial (1% silver sulfadiazine-SSD) surfactant-based wound dressing in the control of Pseudomonas aeruginosa, Enterococcus sp, Staphylococcus epidermidis, Staphylococcus aureus, and methicillin-resistant S. aureus (MRSA) biofilms. Anti-biofilm efficacy was evaluated in numerous adapted American Standards for Testing and Materials (ASTM) standard biofilm models and other bespoke biofilm models. The ASTM standard models employed included the Minimum biofilm eradication concentration (MBEC) biofilm model (ASTM E2799) and the Centers for Disease Control (CDC) biofilm reactor model (ASTM 2871). Such bespoke biofilm models included the filter biofilm model and the chamberslide biofilm model. Results showed complete kill of microorganisms within a biofilm using the antimicrobial surfactant-based wound dressing. Interestingly, the nonantimicrobial surfactant-based dressing could disrupt existing biofilms by causing biofilm detachment. Prior to biofilm detachment, we demonstrated, using confocal laser scanning microscopy (CLSM), the dispersive effect of the nonantimicrobial surfactant-based wound dressing on the biofilm within 10 minutes of treatment. Furthermore, the non-antimicrobial surfactant-based wound dressing caused an increase in microbial flocculation/aggregation, important for microbial concentration. In conclusion, this nonantimicrobial surfactant-based wound dressing leads to the effective detachment and dispersion of in vitro biofilms. The use of surfactant-based wound dressings in a clinical setting may help to disrupt existing biofilm from wound tissue and may increase the action of antimicrobial treatment. © 2017 by the Wound Healing Society.
N-Halamine Biocidal Materials with Superior Antimicrobial Efficacies for Wound Dressings.
Demir, Buket; Broughton, Roy M; Qiao, Mingyu; Huang, Tung-Shi; Worley, S D
2017-09-21
This work demonstrated the successful application of N-halamine technology for wound dressings rendered antimicrobial by facile and inexpensive processes. Four N-halamine compounds, which possess different functional groups and chemistry, were synthesized. The N-halamine compounds, which contained oxidative chlorine, the source of antimicrobial activity, were impregnated into or coated onto standard non-antimicrobial wound dressings. N-halamine-employed wound dressings inactivated about 6 to 7 logs of Staphylococcus aureus and Pseudomonas aeruginosa bacteria in brief periods of contact time. Moreover, the N-halamine-modified wound dressings showed superior antimicrobial efficacies when compared to commercially available silver wound dressings. Zone of inhibition tests revealed that there was no significant leaching of the oxidative chlorine from the materials, and inactivation of bacteria occurred by direct contact. Shelf life stability tests showed that the dressings were stable to loss of oxidative chlorine when they were stored for 6 months in dark environmental conditions. They also remained stable under florescent lighting for up to 2 months of storage. They could be stored in opaque packaging to improve their shelf life stabilities. In vitro skin irritation testing was performed using a three-dimensional human reconstructed tissue model (EpiDerm™). No potential skin irritation was observed. In vitro cytocompatibility was also evaluated. These results indicate that N-halamine wound dressings potentially can be employed to prevent infections, while at the same time improving the healing process by eliminating undesired bacterial growth.
Dressing wear time after breast reconstruction: study protocol for a randomized controlled trial
2013-01-01
Background One of the major risk variables for surgical site infection is wound management. Understanding infection risk factors for breast operations is essential in order to develop infection-prevention strategies and improve surgical outcomes. The aim of this trial is to assess the influence of dressing wear time on surgical site infection rates and skin colonization. Patients’ perception at self-assessment will also be analyzed. Methods/Design This is a two-arm randomized controlled trial. Two hundred breast cancer patients undergoing immediate or delayed breast reconstruction will be prospectively enrolled. Patients will be randomly allocated to group I (dressing removed on postoperative day one) or group II (dressing removed on postoperative day six). Surgical site infections will be defined by standard criteria from the Centers for Disease Control and Prevention (CDC). Skin colonization will be assessed by culture of samples collected at predefined time points. Patients will score dressing wear time with regard to safety, comfort and convenience. Discussion The evidence to support dressing standards for breast surgery wounds is empiric and scarce. CDC recommends protecting, with a sterile dressing for 24 to 48 hours postoperatively, a primarily closed incision, but there is no recommendation to cover this kind of incision beyond 48 hours, or on the appropriate time to shower or bathe with an uncovered incision. The results of the ongoing trial may support standard recommendations regarding dressing wear time after breast reconstruction. Trial registration ClinicalTrials.gov identifier: http://NCT01148823. PMID:23432779
Jin, Sung Giu; Yousaf, Abid Mehmood; Kim, Kyeong Soo; Kim, Dong Wuk; Kim, Dong Shik; Kim, Jin Ki; Yong, Chul Soon; Youn, Yu Seok; Kim, Jong Oh; Choi, Han-Gon
2016-03-30
The purpose of this study was to investigate the influence of different hydrophilic polymers on the swelling, bioadhesion and mechanical strength of hydrocolloid wound dressings (HCDs) in order to provide an appropriate composition for a hydrocolloid wound dressing system. In this study, the HCDs were prepared with styrene-isoprene-styrene copolymer (SIS) and polyisobutylene (PIB) as the base using a hot melting method. Additionally, numerous SIS/PIB-based HCDs were prepared with six hydrophilic polymers, and their wound dressing properties were assessed. Finally, the wound healing efficacy of the selected formulations was compared to a commercial wound dressing. The swelling ratio, bioadhesive force and mechanical strengths of HCDs were increased in the order of sodium alginate>sodium CMC=poloxamer=HPMC>PVA=PVP, sodium alginate>sodium CMC=poloxamer>PVA>HPMC=PVP and sodium alginate≥PVA>PVP=HPMC=sodium CMC>poloxamer, respectively. Among the hydrophilic polymers tested, sodium alginate most enhanced the swelling capacity, bioadhesive force and mechanical strengths. Thus, the hydrophilic polymers played great role in the swelling, bioadhesion and mechanical strength of SIS/PIB-based HCDs. The HCD formulation composed of PIB, SIS, liquid paraffin and sodium alginate at the weight ratio of 20/25/12/43 gave better wound dressing properties and more excellent wound healing efficacy than the commercial wound dressing. Therefore, the novel HCD formulation could be a promising hydrocolloid system for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.
A Wireless Electroceutical Dressing Lowers Cost of Negative Pressure Wound Therapy
Ghatak, Piya Das; Schlanger, Richard; Ganesh, Kasturi; Lambert, Lynn; Gordillo, Gayle M.; Martinsek, Patsy; Roy, Sashwati
2015-01-01
Objective: To test whether the use of a wireless electroceutical dressing (WED) (Procellera®) in conjunction with a 5-day negative pressure wound therapy (NPWT) may reduce the number of dressing changes required per week with this therapy. Approach: At the Ohio State University Comprehensive Wound Center, chronic wound patients (n=30) undergoing NPWT were randomized into two arms following consent as approved by the institutional review board. The control arm received standard of care NPWT, where the dressing change was performed thrice a week. The test arm received the same care except that the WED was added as an interface layer and dressing change was limited to twice a week. Results: A reduced cost of care was achieved using the WED in conjunction with NPWT. Despite fewer dressing changes in wounds dressed with the WED, closure outcomes were comparable with no overt signs of any wound complication, including infection. The cost of NPWT care during the week was significantly lower (from $2918 to $2346) in the WED-treated group compared with patients in the control arm. Innovation: This work introduces a novel technology platform involving a WED, which may be used in conjunction with NPWT. If used as such, NPWT is effective in decreasing the frequency of dressing change and lowering the cost of care. Conclusion: This work points toward the benefit of using the WED combined with NPWT. A larger clinical trial investigating the cost-effectiveness of WED in wound care is warranted. PMID:26005596
Abrigo, Martina; Kingshott, Peter; McArthur, Sally L
2015-12-06
Control over bacterial attachment and proliferation onto nanofibrous materials constitutes a major challenge for a variety of applications, including filtration membranes, protective clothing, wound dressings, and tissue engineering scaffolds. To develop effective devices, the interactions that occur between bacteria and nanofibers with different morphological and physicochemical properties need to be investigated. This paper explores the influence of fiber surface chemistry on bacterial behavior. Different chemical functionalities were generated on the surface of electrospun polystyrene nanofibers through plasma polymerization of four monomers (acrylic acid, allylamine, 1,7-octadiene, and 1,8-cineole). The interactions of Escherichia coli with the surface modified fibers were investigated through a combination of scanning electron microscopy and confocal laser scanning microscopy. Fiber wettability, surface charge, and chemistry were found to affect the ability of bacterial cells to attach and proliferate throughout the nanofiber meshes. The highest proportion of viable cells attachment occurred on the hydrophilic amine rich coating, followed by the hydrophobic octadiene. The acrylic acid coating rich in carboxyl groups showed a significantly lower attraction of bacterial cells. The 1,8-cineole retained the antibacterial activity of the monomer, resulting with a high proportion of dead isolated cells attached onto the fibers. Results showed that the surface chemistry properties of nanofibrous membranes can be strategically tuned to control bacterial behavior.
Use of a copolymer dressing on superficial and partial-thickness burns in a paediatric population.
Everett, M; Massand, S; Davis, W; Burkey, B; Glat, P M
2015-07-01
Despite extensive research into the treatment of partial-thickness burns, to date there has not been the emergence of a preeminent modality. This pilot study, the first such study to be performed in a burn unit in the US, was designed to evaluate the efficacy and outcomes of the application of copolymer dressing (Suprathel; PolyMedics Innovations Corporation, Stuttgart, Germany) for both superficial and deeper partial-thickness burns. The copolymer dressing was used as a primary wound dressing to treat superficial and deep partial-thickness burns (average 5% total body surface area) in paediatric patients. Burns were debrided within 24 hours, at bedside, in the burn unit or in the operating room. The copolymer dressing was then applied directly to the wound and covered with a non-adherent second layer and an absorptive outer dressing. After discharge, patients were seen every 5-7 days until healed. Parameters evaluated included average hospital length of stay, average number of intravenous doses of narcotics administered, pain score at first follow-up visit, average time to complete re epithelialisation, incidence of burn wound infection, and patient/parent satisfaction on a 4-point scale. We also evaluated our experience with the dressing. Data were evaluated retrospectively under an Investigational Review Board approved protocol. Of the 17 patients assessed the average hospital length of stay was 1.4 days during which the average number of intravenous narcotic doses administered before copolymer dressing application was 1.5 and after was 0.1 doses. At the first follow-up visit, average pain score was 1.2 on a 10-point scale and the average time to re epithelialisation was 9.5 days. There was no incidence of burn wound infection. Patient/parent satisfaction was average of 3.66 on a 4-point scale. The staff had found that the self-adherence and elasticity of the dressing made it easy to apply and stay adherent, especially in areas of difficult contour. There were no readmissions for further debridement or skin grafting. Our experience shows that patients may be discharged shortly after the application of the copolymer dressing, with manageable pain scores and ease of use as determined by the caretakers high satisfaction. This new, fully synthetic copolymer dressing is easy to apply, does not require any additional antimicrobial coverage and may be used to successfully manage deeper partial-thickness burns, donor sites or burns in areas of contour, where many other dressings might not be considered or be appropriate. None declared.
Extremity War Injuries: Current Management and Research Priorities
2012-01-01
sal- vage and amputation. The 13 articles generated from this symposium ad- dress these topics as well as multi- modal strategies for pain control...reconstruction, and reha- bilitation. The last seven articles of this supplement address lessons learned, outcomes measures, current strategies, and knowledge... bioburden , which has resulted in im- proved patient care. At the EWI VII Symposium, sev- eral research priorities were outlined in the areas of acute care
Professional Characteristics Communicated by Formal versus Casual Workplace Attire
ERIC Educational Resources Information Center
Cardon, Peter W.; Okoro, Ephraim A.
2009-01-01
Employees are frequently advised to dress for success to build their careers. From the corporate perspective, employees who are well dressed are believed to form better impressions with colleagues, clients, and customers. Many companies create dress codes in order to gain the benefits of a professionally appearing workforce. Developing effective…
Identification of Workplace Dress by Low-Income Job Seekers
ERIC Educational Resources Information Center
Saiki, Diana
2013-01-01
The author examined how low-income job seekers participating in a workplace dress program identified traditional business and business casual dress. Seventy low-income job seekers identified clothing items as traditional business (e.g., suits, ties), similar to identifications made by professionals and image consultants in previous literature.…
ERIC Educational Resources Information Center
Lumsden, Linda; Miller, Gabriel
2002-01-01
Students do not always make choices that adults agree with in their choice of school dress. Dress-code issues are explored in this Research Roundup, and guidance is offered to principals seeking to maintain a positive school climate. In "Do School Uniforms Fit?" Kerry White discusses arguments for and against school uniforms and summarizes the…
Counterconformity: An Attribution Model of Adolescents' Uniqueness-Seeking Behaviors in Dressing
ERIC Educational Resources Information Center
Ling, I-Ling
2008-01-01
This article explores how an attribution model will illustrate uniqueness-seeking behavior in dressing in the Taiwanese adolescent subculture. The study employed 443 senior high school students. Results show that the tendency of uniqueness-seeking behavior in dressing is moderate. However, using cluster analysis to segment the counterconformity…
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
21 CFR 878.4018 - Hydrophilic wound dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydrophilic wound dressing. 878.4018 Section 878.4018 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4018 Hydrophilic wound dressing...
21 CFR 878.4020 - Occlusive wound dressing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...
9 CFR 108.9 - Dressing rooms and other facilities.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Dressing rooms and other facilities. 108.9 Section 108.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT... REQUIREMENTS FOR LICENSED ESTABLISHMENTS § 108.9 Dressing rooms and other facilities. Each licensed...
2003-09-01
Pharmaceuticals, Inc. (Westlake, OH), submitted the Hemarrest dressing. This dressing was a thin, sheet-like pad with a mixture of epsilon aminocaproic acid ...chloric acid salt purified bovine corium collagen. It was prepared in a compacted nonwoven web form (7.0 7.0 cm). Ethicon, Inc. (Somerville, NJ...may be related to enhanced platelet procoagulant activity and annexin V binding.46 Another derivative of gallic acid , bis- muth subgallate, appears to
An evaluation of a silicone adhesive shaped heel dressing.
Hampton, Sylvie
Tissue breakdown is complex and involves many factors. Pressure ulcer development in the heels is subject to extrinsic factors such as pressure, shear, friction and moisture. The heels are the most common sites for friction and shear damage, which can lead to blistering, skin erosion and tissue breakdown (Grey et al, 2006). To address the issues of wounds that are painful on dressing removal and friable skin, Smith & Nephew has introduced a soft silicone adhesive dressing to its Allevyn dressing range. Silicone does not adhere to wounded areas and can be removed gently without trauma to the periwound area. This paper discusses the findings of a 20-patient multi-site evaluation examining the performance and acceptability of Allevyn Gentle Border Heel dressing in the management of heel wounds.
The use of prophylactic dressings in the prevention of pressure ulcers: a literature review.
Cornish, Lynn
2017-06-02
Pressure ulcers pose a significant burden to both patients and health care resources. There are an increasing number of studies that have examined the use of prophylactic dressings, and their ability to redistribute pressure and protect the skin from shear and friction damage. This literature review examines six studies conducted on this controversial subject. Brindle and Wegelin ( 2012 ; Chaiken, 2012 ; Cubit et al, 2012 ; Santamaria et al, 2012) all examined the role of dressings to prevent pressure ulcers, and Call et al (2013a ; 2013b ), conducted in vitro research into the mode of dressings. Current research suggests that while further research is required, the use of prophylactic dressings have a place alongside standard measures, in helping to prevent pressure, shear and friction damage.
Wound dressings from naturally-occurring polymers: A review on homopolysaccharide-based composites.
Naseri-Nosar, Mahdi; Ziora, Zyta Maria
2018-06-01
Wound dressings are designed to support the wound bed and protect it from the factors that may delay or impede its healing such as contaminations and moisture-loss, thereby facilitating and accelerating the healing process. The materials used to prepare wound dressings include natural and synthetic polymers, as well as their combinations, in the forms of films, sponges and hydrogels. Polysaccharides are naturally-occurring polymers that have been extensively used as wound dressing materials. Homopolysaccharides are a class of polysaccharides consist of only one type of monosaccharide. The current review intends to overview the studies in which wound dressings from naturally-occurring polymers, based on homopolysaccharides, were prepared and evaluated. Homopolysaccharides such as cellulose, chitosan, chitin, pullulan, starch and β-glucan were considered. Copyright © 2018 Elsevier Ltd. All rights reserved.
She Wears the Pants: The Reform Dress as Technology in Nineteenth-Century America.
Mas, Catherine
This article examines the American dress-reform movement, detailing the ways in which reformers conceptualized clothing as a social and bodily technology. In the mid-nineteenth century, women began making and wearing the "reform dress"-a costume consisting of pants and shortened, lightweight skirts-as an alternative to burdensome feminine fashions. When ridiculed in public for wearing overtly masculine garments, dress reformers insisted their clothing was healthful, functional, and natural. This article discusses women's use of medical science and technical knowledge in their rejection of fashion, promotion of sexual equality, and efforts to change mainstream clothing practices. When approached from a technological perspective, the reform dress reveals broader tensions in an industrializing American society, such as changing gender relations and new understandings of the relationship between humans and technology.
Dabiri, Ganary; Hammerman, Scott; Falanga, Vincent
2014-01-01
Venous leg ulcers affect millions of patients worldwide and are a tremendous financial burden on our healthcare system. The hallmark of venous disease of the lower extremities is venous hypertension, and compression is the current mainstay of treatment. However, many patients are noncompliant, in part because of the complexity of the dressings and the difficulties with application and removal. The aim of our study was to determine an effective compression dressing regimen for patients with venous leg ulcers who require changing the ulcer primary dressing twice daily. We used two layers of a latex free tubular elastic bandage for compression. The primary endpoint of our study was increased wound healing rate and our secondary endpoint was complete wound closure. All active study subjects had positive healing rates at week 4 and week 8. Two subjects achieved complete wound closure by week 8. We conclude that compression with a latex-free tubular elastic bandage can be safely used in patients with venous leg ulcers requiring frequent dressing changes. This type of compression allows for daily inspection of wounds, dressing changes at home, flexibility in the context of clinical trials, and is a compromise for patients that are intolerant to compression dressings. PMID:24267477
Effect of music intervention on burn patients' pain and anxiety during dressing changes.
Hsu, Kuo-Cheng; Chen, Li Fen; Hsiep, Pi Hsia
2016-12-01
For burn patients, the daily dressing process causes pain and anxiety. Although drugs can relieve them, the degree of pain during dressing changes is often moderate to severe. Therefore, relevant supporting interventions, like music as an ideal intervention, could alleviate the patient's pain. This study investigated the impact of music intervention at dressing change time on burn patients' pain and anxiety. This was a prospective, randomized clinical trial; patients were randomly assigned into control (standard intervention) and experimental groups (crystal music intervention) for five consecutive days (35 patients in each group). Patients' pain and anxiety measurements were collected before, during, and after dressing changes and morphine usage was recorded. The study period was October 2014 to September 2015. There was no difference in morphine dosage for both groups. By the fourth day of music intervention, burn patients' pain before, during, and after dressing changes had significantly decreased; anxiety on the fourth day during and after dressing changes had also significantly decreased. Nurses may use ordered prescription analgesics, but if non-pharmacological interventions are increased, such as providing timely music intervention and creating a friendly, comfortable hospital environment, patients' pain and anxiety will reduce. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Sahraro, Maryam; Yeganeh, Hamid; Sorayya, Marziyeh
2016-02-01
Preparation and assessments of novel absorptive wound dressing materials with efficient antimicrobial activity as well as very good cytocompatibility were described in this work. An amine terminated poly(hexamethylene guanidine hydrochloride) was prepared and used as curing agent of different epoxy-terminated polyurethane prepolymers. The structures of prepared materials were elucidated by evaluation of their (1)H NMR and FTIR spectra. The recorded tensile strength of membranes confirmed the excellent dimensional stability of the film type dressings even at fully hydrated conditions. Therefore, these dressings could protect the wound bed from external forces during the healing period. The structurally optimized dressing membranes could preserve the desired moist environment over the wounded area, as a result of their balanced equilibrium, water absorption and water vapor transmission rate. Therefore, a very good condition for stimulation of self-healing of wound bed was attained. Also, owing to the presence of guanidine hydrochloride moieties embedded into the structure of dressings, efficient antimicrobial activity against Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans were detected. In vitro cytotoxicity assay of the prepared dressings revealed cytocompatibility of these materials against fibroblast cells. Therefore, they could support cell growth and proliferation at the wounded area. Copyright © 2015 Elsevier B.V. All rights reserved.
Fontaine, Mathieu; Latarjet, Jacques; Payre, Jacqueline; Poupelin, Jean-Charles; Ravat, François
2017-03-01
The severe pain related to repeated burn dressing changes at bedside is often difficult to manage. However these dressings can be performed at bedside on spontaneously breathing non-intubated patients using powerful intravenous opioids with a quick onset and a short duration of action such as alfentanil. The purpose of this study is to demonstrate the efficacy and safety of the protocol which is used in our burn unit for pain control during burn dressing changes. Cohort study began after favorable opinion from local ethic committee has been collected. Patient's informed consent was collected. No fasting was required. Vital signs for patients were continuously monitored (non-invasive blood pressure, ECG monitoring, cutaneous oxygen saturation, respiratory rate) all over the process. Boluses of 500 (±250) mcg IV alfentanil were administered. A continuous infusion was added in case of insufficient analgesia. Adverse reactions were collected and pain intensity was measured throughout the dressing using a ten step verbal rating scale (VRS) ranging from 0 (no pain) to 10 (worst pain conceivable). 100 dressings (35 patients) were analyzed. Median age was 45 years and median burned area 10%. We observed 3 blood pressure drops, 5 oxygen desaturations (treated with stimulation without the necessity of ventilatory support) and one episode of nausea. Most of the patients (87%) were totally conscious during the dressing and 13% were awakened by verbal stimulation. Median total dose of alfentanil used was 2000μg for a median duration of 35min. Pain scores during the procedure were low or moderate (VRS mean=2.0 and maximal VRS=5). Median satisfaction collected 2h after the dressing was 10 on a ten step scale. Pain control with intravenous alfentanil alone is efficient and appears safe for most burn bedside repeated dressings in hospitalized patients. It achieves satisfactory analgesia during and after the procedure. It is now our standard analgesic method to provide repeated bedside dressings changes for burned patients. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Forsberg, Björn; Ulander, Johan; Kjellander, Roland
2005-02-08
The effects of ionic size asymmetry on long-range electrostatic interactions in electrolyte solutions are investigated within the primitive model. Using the formalism of dressed ion theory we analyze correlation functions from Monte Carlo simulations and the hypernetted chain approximation for size asymmetric 1:1 electrolytes. We obtain decay lengths of the screened Coulomb potential, effective charges of ions, and effective permittivity of the solution. It is found that the variation of these quantities with the degree of size asymmetry depends in a quite intricate manner on the interplay between the electrostatic coupling and excluded volume effects. In most cases the magnitude of the effective charge of the small ion species is larger than that of the large species; the difference increases with increasing size asymmetry. The effective charges of both species are larger (in absolute value) than the bare ionic charge, except for high asymmetry where the effective charge of the large ions can become smaller than the bare charge.
Renormalization group method based on the ionization energy theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arulsamy, Andrew Das, E-mail: sadwerdna@gmail.com; School of Physics, University of Sydney, Sydney, New South Wales 2006
2011-03-15
Proofs are developed to explicitly show that the ionization energy theory is a renormalized theory, which mathematically exactly satisfies the renormalization group formalisms developed by Gell-Mann-Low, Shankar and Zinn-Justin. However, the cutoff parameter for the ionization energy theory relies on the energy-level spacing, instead of lattice point spacing in k-space. Subsequently, we apply the earlier proofs to prove that the mathematical structure of the ionization-energy dressed electron-electron screened Coulomb potential is exactly the same as the ionization-energy dressed electron-phonon interaction potential. The latter proof is proven by means of the second-order time-independent perturbation theory with the heavier effective mass condition,more » as required by the electron-electron screened Coulomb potential. The outcome of this proof is that we can derive the heat capacity and the Debye frequency as a function of ionization energy, which can be applied in strongly correlated matter and nanostructures.« less
Pouthier, Vincent
2012-11-07
A communication protocol is proposed in which vibron-mediated quantum state transfer takes place in a molecular lattice. We consider two distant molecular groups grafted on each side of the lattice. These groups form two quantum computers where vibrational qubits are implemented and received. The lattice defines the communication channel along which a vibron delocalizes and interacts with a phonon bath. Using quasi-degenerate perturbation theory, vibron-phonon entanglement is taken into account through the effective Hamiltonian concept. A vibron is thus dressed by a virtual phonon cloud whereas a phonon is clothed by virtual vibronic transitions. It is shown that three quasi-degenerate dressed states define the relevant paths followed by a vibron to tunnel between the computers. When the coupling between the computers and the lattice is judiciously chosen, constructive interference takes place between these paths. Phonon-induced decoherence is minimized and a high-fidelity quantum state transfer occurs over a broad temperature range.
Incremental concept learning with few training examples and hierarchical classification
NASA Astrophysics Data System (ADS)
Bouma, Henri; Eendebak, Pieter T.; Schutte, Klamer; Azzopardi, George; Burghouts, Gertjan J.
2015-10-01
Object recognition and localization are important to automatically interpret video and allow better querying on its content. We propose a method for object localization that learns incrementally and addresses four key aspects. Firstly, we show that for certain applications, recognition is feasible with only a few training samples. Secondly, we show that novel objects can be added incrementally without retraining existing objects, which is important for fast interaction. Thirdly, we show that an unbalanced number of positive training samples leads to biased classifier scores that can be corrected by modifying weights. Fourthly, we show that the detector performance can deteriorate due to hard-negative mining for similar or closely related classes (e.g., for Barbie and dress, because the doll is wearing a dress). This can be solved by our hierarchical classification. We introduce a new dataset, which we call TOSO, and use it to demonstrate the effectiveness of the proposed method for the localization and recognition of multiple objects in images.
Ampawong, Sumate; Aramwit, Pornanong
2017-09-01
In this study, three kinds of antiseptics which were 0.05% chlorhexidine, 0.2% polyhexamethylene biguanide (PHMB), or 200 ppm silver nanoparticle was introduced to incorporate in the sericin-based scaffold to produce the antimicrobial dressing for the treatment of infected chronic wound. The effects of antiseptic incorporation on the stability, release of sericin, and short-term and long-term (6 months) antimicrobial activity of the sericin dressing against gram-negative and gram-positive bacteria were investigated. We showed that the incorporation of each antiseptic did not have significant effect on the internal morphology (pore size ~ 73-105 μm), elasticity (Young's modulus ~ 200-500 kPa), and the sericin release behavior of the sericin-based dressing. The release of sericin from the dressing was prolonged over 120 h and thereafter. Comparing among three antiseptics, 0.05% chlorhexidine incorporated in the sericin dressing showed the highest immediate and long-term (6 months) antimicrobial effect (largest inhibition zone) against most bacteria either gram-positive or gram-negative bacteria. The in vivo safety test following ISO10993 standard (Biological evaluation of medical devices - Part 6: Tests for local effects after implantation) confirmed that the sericin dressing incorporating 0.05% chlorhexidine did not irritate to tissue, comparing with the commercial material used generally in clinic (Allevyn®, Smith & Nephew). We suggested the sericin dressing incorporating 0.05% chlorhexidine for the treatment of infected chronic wound. Chlorhexidine would reduce the risk of infection while the sericin may promote wound healing.
Bikmoradi, Ali; Harorani, Mehdi; Roshanaei, Ghodratollah; Moradkhani, Shirin; Falahinia, Golam Hossein
2016-01-01
Pain is one of the common problems encountered by patients with burns, which increases after each dressing. This study aimed to investigate the effect of inhalation aromatherapy with damask rose essence on the pain of patients with burns that is caused after dressing. A randomized clinical trial was conducted on 50 patients with second- and third-degree burn wounds. The baseline pain of the patients was assessed 30 min before they entered into the dressing room on the first and second days of intervention. The patients in the experimental group inhaled five drops of damask rose essence 40% in distilled water, while those in the control group inhaled five drops of distilled water as placebo. The pain intensity was assessed using Visual Analogue Scale at 15 and 30 min after the patients exited from the dressing room. Data were analyzed by SPSS (version 18) using descriptive and inferential statistics. There was significant difference between the mean of pain intensity before and after intervention at 15 and 30 min after dressing (P < 0.001). Moreover, there was significant difference in reduction of pain intensity before and after aromatherapy in the experimental group (P < 0.05). Also, there was a significant reduction in severity of pain after dressing in the experimental group compared with the control group (P < 0.05). Inhalation aromatherapy with damask rose could be effective for relieving the pain caused after dressing in patients with burns. Therefore, it could be suggested as a complementary therapy in burn patients for pain relief.
Prophylactic Sacral Dressing for Pressure Ulcer Prevention in High-Risk Patients.
Byrne, Jaime; Nichols, Patricia; Sroczynski, Marzena; Stelmaski, Laurie; Stetzer, Molly; Line, Cynthia; Carlin, Kristen
2016-05-01
Patients in intensive care units are likely to have limited mobility owing to hemodynamic instability and activity orders for bed rest. Bed rest is indicated because of the severity of the disease process, which often involves intubation, sedation, paralysis, surgical procedures, poor nutrition, low flow states, and poor circulation. These patients are predisposed to the development and/or the progression of pressure ulcers not only because of their underlying diseases, but also because of limited mobility and deconditioned states of health. To assess whether treating high-risk patients with a prophylactic sacral dressing decreases the incidence of unit-acquired sacral pressure ulcers. An evidence-based tool for identifying patients at high risk for pressure ulcers was used in 3 intensive care units at an urban tertiary care hospital and academic medical center. Those patients deemed at high risk had a prophylactic sacral dressing applied. Incidence rates were collected and compared for the 7 months preceding use of the dressings and for 7 months during the trial period when the dressing was used. After the sacral dressing began being used, the number of unit-acquired sacral pressure ulcers decreased by 3.4 to 7.6 per 1000 patient days depending on the unit. A prophylactic sacral dressing may help prevent unit-acquired sacral pressure ulcers. Implementation of an involved care team with heightened awareness and increased education along with a prophylactic sacral dressing in patients deemed high risk for skin breakdown are all essential for success. ©2016 American Association of Critical-Care Nurses.
NASA Astrophysics Data System (ADS)
Patil, Sanjay S.; Bhalerao, Yogesh J.
2017-02-01
Grinding is metal cutting process used for mainly finishing the automobile components. The grinding wheel performance becomes dull by using it most of times. So it should be reshaping for consistent performance. It is necessary to remove dull grains of grinding wheel which is known as dressing process. The surface finish produced on the work piece is dependent on the dressing parameters in sub-sequent grinding operation. Multi-point diamond dresser has four important parameters such as the dressing cross feed rate, dressing depth of cut, width of the diamond dresser and drag angle of the dresser. The range of cross feed rate level is from 80-100 mm/min, depth of cut varies from 10 - 30 micron, width of diamond dresser is from 0.8 - 1.10mm and drag angle is from 40o - 500, The relative closeness to ideal levels of dressing parameters are found for surface finish produced on the En-31 work piece during sub-sequent grinding operation by using Technique of Order Preference by Similarity to Ideal Solution (TOPSIS).In the present work, closeness to ideal solution i.e. levels of dressing parameters are found for Computer Numerical Control (CNC) cylindrical angular grinding machine. After the TOPSIS technique, it is found that the value of Level I is 0.9738 which gives better surface finish on the En-31 work piece in sub-sequent grinding operation which helps the user to select the correct levels (combinations) of dressing parameters.
Medical workers' cognition of using 50% nitrous oxide in children with burns: a qualitative study.
Wang, Hai-Xia; Li, Yu-Xiang; Zhou, Ru-Zhen; Zhao, Ji-Jun
2015-09-01
Pain caused by dressing among children with burns is an issue worth discussing. Medical workers' understanding of pain during dressing in children with burns is correlated with the quality of pain management. Effective pain management is significant to improve anxiety and reduce pain and psychological distress during dressing for children with burns. We aimed to investigate medical workers' understanding of current pain management during dressing among children with burns and their attitudes toward the application of 50% nitrous oxide in pain management. Interviews were conducted with seven doctors and nurses from a burn center in East China. Data were collected by in-depth interviews and qualitative description after full transcription of each interview. Three themes were identified: (1) Medical workers felt sympathy for children with burns and believed that a gap existed between the current and expected situation in pain management. In addition, the prescription of analgesics during dressing for children with burns was not favored. (2) Given the fact that 50% nitrous oxide is effective in pain management for adult patients with burns, medical workers tended to apply it to children with burns during dressing after being provided the literature on the use of 50% nitrous oxide in children. (3) Guidelines for the application of 50% nitrous oxide during dressing for children with burns require further modification. Medical workers deemed the pain management for children with burns unsatisfactory, and they supported the application of 50% nitrous oxide during dressing for children with burns. Meanwhile, they hoped that administrators would also support it. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Tan, Xueli; Yowler, Charles J; Super, Dennis M; Fratianne, Richard B
2010-01-01
The purpose of this study was to explore the efficacy of two music therapy protocols on pain, anxiety, and muscle tension levels during dressing changes in burn patients. Twenty-nine inpatients participated in this prospective, crossover randomized controlled trial. On two consecutive days, patients were randomized to receive music therapy services either on the first or second day of the study. On control days, they received no music. On music days, patients practiced music-based imagery (MBI), a form of music-assisted relaxation with patient-specific mental imagery before and after dressing changes. Also, on music days during dressing changes, the patients engaged in music alternate engagement (MAE), which consisted of active participation in music making. The dependent variables were the patients' subjective ratings of their pain and anxiety levels and the research nurse's objective ratings of their muscle tension levels. Two sets of data were collected before, three sets during, and another two sets after dressing changes. The results showed significant decrease in pain levels before (P < .025), during (P < .05), and after (P < .025) dressing changes on days the patients received music therapy in contrast to control days. Music therapy was also associated with a decrease in anxiety and muscle tension levels during the dressing changes (P < .05) followed by a reduction in muscle tension levels after dressing changes (P < .025). Music therapy significantly decreases the acute procedural pain, anxiety, and muscle tension levels associated with daily burn care.
#TheDress: Categorical perception of an ambiguous color image.
Lafer-Sousa, Rosa; Conway, Bevil R
2017-10-01
We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region.
What #theDress reveals about the role of illumination priors in color perception and color constancy
Aston, Stacey; Hurlbert, Anya
2018-01-01
The disagreement between people who named #theDress (the Internet phenomenon of 2015) “blue and black” versus “white and gold” is thought to be caused by individual differences in color constancy. It is hypothesized that observers infer different incident illuminations, relying on illumination “priors” to overcome the ambiguity of the image. Different experiences may drive the formation of different illumination priors, and these may be indicated by differences in chronotype. We assess this hypothesis, asking whether matches to perceived illumination in the image and/or perceived dress colors relate to scores on the morningness-eveningness questionnaire (a measure of chronotype). We find moderate correlations between chronotype and illumination matches (morning types giving bluer illumination matches than evening types) and chronotype and dress body matches, but these are significant only at the 10% level. Further, although inferred illumination chromaticity in the image explains variation in the color matches to the dress (confirming the color constancy hypothesis), color constancy thresholds obtained using an established illumination discrimination task are not related to dress color perception. We also find achromatic settings depend on luminance, suggesting that subjective white point differences may explain the variation in dress color perception only if settings are made at individually tailored luminance levels. The results of such achromatic settings are inconsistent with their assumed correspondence to perceived illumination. Finally, our results suggest that perception and naming are disconnected, with observers reporting different color names for the dress photograph and their isolated color matches, the latter best capturing the variation in the matches. PMID:28793353
#TheDress: Categorical perception of an ambiguous color image
Lafer-Sousa, Rosa; Conway, Bevil R.
2017-01-01
We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region. PMID:29090319
Black, Jonathan S; Drake, David B
2015-01-01
The lipid base of silver sulfadiazine (SSD) makes removal of the product painful for the patient and difficult for the physician to accurately assess particularly in partial-thickness burn injuries. As an alternative, a water-soluble antimicrobial gel is used at the University of Virginia. We present a prospective, randomized comparison of these two therapies using pain with dressing changes and time to perform dressing changes as our primary endpoints. Adult inpatients with partial-thickness burn wounds were randomized to begin therapy with either SSD cream or the water-soluble burn wound gel (BWG), and then therapies were alternated daily. Pain assessments, time to complete dressing care, total narcotic medication administered, and the number of personnel required for dressing changes were recorded. Eight patients were enrolled resulting in 13 pairs (26 points) of data comparison between the two therapies. Four of the eight enrolled patients (50%) refused to continue receiving SSD because of pain associated with dressing changes and voluntarily withdrew from the study. The amount of time to perform dressing changes was an average of 79 nurse-minutes longer for SSD. A 6.08 greater morphine equivalent was delivered to those having BWG removed.A water-soluble polyantimicrobial gel was superior to SSD in the parameters measured as exhibited by our patient dropout rate and differential time to perform dressing care. Limiting the time to perform dressing care will reduce the cumulative pain experience, improve patient satisfaction, and reduce the resources to deliver care.
Fashion as Argument: Nineteenth-Century Dress Reform.
ERIC Educational Resources Information Center
Torrens, Kathleen M.
1999-01-01
Examines the place of the body in the dress-reform movement, a social movement that focused on fashion as a vehicle for achieving social and political equality. Discusses how fashion became one arena in which definitions of gender were contested. Suggests the dress-reform movement's failure in redefining femininity indicates the depth of…
ERIC Educational Resources Information Center
Chatelain, Amber M.
2015-01-01
This study sought to discover student perceptions of academics' dress and gender and their impact on perceived instructor approachability and likeability. Three categories of dress were examined: casual, business casual and professional. The results of this study suggest students at career-arts institutions perceive female teachers as less…
ERIC Educational Resources Information Center
Freeburg, Beth Winfrey; Workman, Jane E.
2010-01-01
The purpose of this study was to explore teacher dress in United States schools as presented in the newspaper. Twenty-nine articles were examined to answer three questions. Results revealed: (a) the newspaper provided four contexts for processing information about teacher dress--roles, control, impression management, and educational learning…
Dress-Related Responses to the Columbine Shootings: Other-Imposed and Self-Designed.
ERIC Educational Resources Information Center
Ogle, Jennifer Paff; Eckman, Molly
2002-01-01
An inductive content analysis approach was used to examine 155 dress-related newspaper articles following the Columbine High School shootings in 1999. Analysis revealed two dress-related responses: (1) other-imposed regulation to protect students and deter them from expressing hatred and (2) self-designed acts of resistance for grieving. (Contains…
ERIC Educational Resources Information Center
Morris, Tracy L.; And Others
1996-01-01
Finds that more formal dress (business suits, dress shoes) was associated with increased ratings of teaching assistants' competence, particularly for female students rating female instructors. Shows, however, that contrary to common assumptions, the most positive influences of instructor dress were found in the highly casual condition (faded…
Effect of Andrographis paniculata leaf extract on wound healing in rats.
Al-Bayaty, Fouad Hussain; Abdulla, Mahmood Ameen; Abu Hassan, Mohamed Ibrahim; Ali, Hapipah Mohd
2012-01-01
This work was carried out to study the effect of topical application of Andrographis paniculata on the rate of wound enclosure and its histological features. A wound was created in four groups of rat in posterior neck region. Blank placebo was applied topically to the wounds of Group 1. Groups 2 and 3 were dressed with placebo containing 5% and 10% extracts of A. paniculata, respectively. Intrasite gel was applied topically to the wounds of Group 4. Macroscopical examination revealed that the rate of wound healing was significantly accelerated in the wound dressed with A. paniculata extract compared to the blank placebo. The wounds dressed with 10% extract or Intrasite gel healed earlier compared to the wounds dressed with placebo containing 5% A. paniculata extract. Histologically, wounds dressed with A. paniculata extracts showed markedly less scar width and contained large amounts of fibroblast proliferation. More collagen and less angiogenesis with absence of inflammatory cells were seen for wounds dressed with 10% A. paniculata compared to the blank placebo. Conclusion, A. paniculata extracts significantly enhanced rate of wound healing in rats.
An in vitro test of the efficacy of an anti-biofilm wound dressing.
Said, Jawal; Walker, Michael; Parsons, David; Stapleton, Paul; Beezer, Anthony E; Gaisford, Simon
2014-10-20
Broad-spectrum antimicrobial agents, such as silver, are increasingly being formulated into medicated wound dressings in order to control colonization of wounds by opportunistic pathogens. Medicated wound dressings have been shown in-vitro to be effective against planktonic cultures, but in-vivo bacteria are likely to be present in biofilms, which makes their control and eradication more challenging. Recently, a functional wound dressing (AQUACEL(®) Ag+ Extra™ (AAg + E)) has been developed that in addition to silver contains two agents (ethylenediaminetetraacetic acid (EDTA) and benzethonium chloride (BC)) designed to disrupt biofilms. Here, the efficacy of AAg + E is demonstrated using a biofilm model developed in an isothermal microcalorimeter. The biofilm was seen to remain viable in the presence of unmedicated dressing, silver-containing dressing or silver nitrate solution. In the presence of AAg + E, however, the biofilm was eradicated. Control experiments showed that neither EDTA nor BC alone had a bactericidal effect, which means it is the synergistic action of EDTA and BC disrupting the biofilm with silver being bactericidal that leads to the product's efficacy. Copyright © 2014 Elsevier B.V. All rights reserved.
Mitchell, Michael S; Koen, Clifford M; Moore, Thomas W
2013-01-01
As more and more individuals choose to express themselves and their religious beliefs with headwear, jewelry, dress, tattoos, and body piercings and push the envelope on what is deemed appropriate in the workplace, employers have an increased need for creation and enforcement of reasonable dress codes and appearance policies. As with any employment policy or practice, an appearance policy must be implemented and enforced without regard to an individual's race, color, sex, national origin, religion, disability, age, or any other protected status. A policy governing dress and appearance based on the business needs of an employer that is applied fairly and consistently and does not have a disproportionate effect on any protected class will generally be upheld if challenged in court. By examining some of the more common legal challenges to dress codes and how courts have resolved the disputes, health care managers can avoid many potential problems. This article addresses the issue of religious discrimination focusing on dress and appearance and some of the court cases that provide guidance for employers.
Dispersive detection of radio-frequency-dressed states
NASA Astrophysics Data System (ADS)
Jammi, Sindhu; Pyragius, Tadas; Bason, Mark G.; Florez, Hans Marin; Fernholz, Thomas
2018-04-01
We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.
Combined therapy of Ulmo honey (Eucryphia cordifolia) and ascorbic acid to treat venous ulcers1
Calderon, Mariano del Sol; Figueroa, Carolina Schencke; Arias, Jessica Salvo; Sandoval, Alejandra Hidalgo; Torre, Felipe Ocharan
2015-01-01
OBJECTIVE: to assess the clinical effect of topical treatment using Ulmo honey associated with oral ascorbic acid in patients with venous ulcers. METHOD: longitudinal and descriptive quantitative study. During one year, 18 patients were assessed who were clinically diagnosed with venous ulcer in different stages, male and female, adult, with a mean injury time of 13 months. Ulmo honey was topically applied daily. The dressing was applied in accordance with the technical standard for advanced dressings, combined with the daily oral consumptions of 500 mg of ascorbic acid. The monitoring instrument is the assessment table of venous ulcers. RESULTS: full healing was achieved in 100% of the venous ulcers. No signs of complications were observed, such as allergies or infection. CONCLUSION: the proposed treatment showed excellent clinical results for the healing of venous ulcers. The honey demonstrated debriding and non-adherent properties, was easy to apply and remove and was well accepted by the users. The described results generated a research line on chronic wound treatment. PMID:26039296
NASA Astrophysics Data System (ADS)
Lundblad, Nathan; Jarvis, Thomas; Paseltiner, Daniel; Lannert, Courtney
2016-05-01
We have proposed using NASA's Cold Atom Laboratory (CAL, launching to the International Space Station in 2017) to generate bubble-geometry Bose-Einstein condensates through radiofrequency dressing of an atom-chip magnetic trap. This geometry has not been truly realized terrestrially due to the perturbing influence of gravity, making it an ideal candidate for microgravity investigation aboard CAL. We report progress in the construction of a functional prototype of the orbital BEC apparatus: a compact atom-chip machine loaded by a 2D+MOT source, conventional 3D MOT, quadrupole trap, and transfer coil. We also present preliminary modeling of the dressed trap uniformity, which will crucially inform the geometric closure of the BEC shell surface as atom number, bubble radius, and bubble aspect ratio are varied. Finally, we discuss plans for experimental sequences to be run aboard CAL guided by intuition from ground-based prototype operation. JPL 1502172.
Wu, Jian; Zheng, Yudong; Song, Wenhui; Luan, Jiabin; Wen, Xiaoxiao; Wu, Zhigu; Chen, Xiaohua; Wang, Qi; Guo, Shaolin
2014-02-15
Bacterial cellulose has attracted increasing attention as a novel wound dressing material, but it has no antimicrobial activity, which is one of critical skin-barrier functions in wound healing. To overcome such deficiency, we developed a novel method to synthesize and impregnate silver nanoparticles on to bacterial cellulose nanofibres (AgNP-BC). Uniform spherical silver nano-particles (10-30 nm) were generated and self-assembled on the surface of BC nano-fibers, forming a stable and evenly distributed Ag nanoparticles coated BC nanofiber. Such hybrid nanostructure prevented Ag nanoparticles from dropping off BC network and thus minimized the toxicity of nanoparticles. Regardless the slow Ag(+) release, AgNP-BC still exhibited significant antibacterial activities with more than 99% reductions in Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa. Moreover, AgNP-BC allowed attachment and growth of epidermal cells with no cytotoxicity emerged. The results demonstrated that AgNP-BC could reduce inflammation and promote wound healing. Copyright © 2013 Elsevier Ltd. All rights reserved.
Günal, Özgür; Tuncel, Umut; Turan, Aydin; Barut, Sener; Kostakoglu, Naci
2015-10-01
The aim of this retrospective study was to evaluate the efficacy of vacuum-assisted closure (VAC) and GranuFoam Silver® dressing (KCI, San Antonio, TX) compared with conventional GranuFoam® dressing in the management of diabetic foot ulcers. Twenty-one consecutive patients treated with conventional or silver-coated foam dressing were reviewed retrospectively. The wound duration was 6 mo. Group 1 (n=10) received conventional foam dressing (GranuFoam) and group 2 (n=11) received silver-coated foam dressing (GranuFoam Silver). The wound surface area, duration of treatment, bacteriology, and recurrence were compared between the groups. The mean age of the patients was 61.70±10.52 y in group 1 and 67.27±11.28 y in group 2. In group 1, the average surface area of the wounds was 45.30±46.96 cm2 and 18.40±23.48 cm2 in the pre-treatment and post-treatment periods, respectively. There was a statistically significant difference between two measurements (p=0.005). Average duration of the treatment was 25.50±27.13 d in this group. In group 2, average surface area of the wounds in the pre-treatment and post-treatment periods were 41.55±36.03 cm2 and 7.64±3.91 cm2, respectively. There was a statistically significant difference between two measurements (p=0.003). Average duration of the treatment was 10.09±3.51 d in this group. The patients treated with silver-impregnated polyurethane foam dressing had reduced recurrence (2 vs. 7 wounds, p=0.030) and increased number of the culture-negative cases at the end of the treatment. With the results of the study, it was concluded that VAC GranuFoam silver dressing can be superior to conventional GranuFoam dressing in reducing the recurrence rate of infected diabetic foot ulcers.
Heyneman, A; Hoeksema, H; Vandekerckhove, D; Pirayesh, A; Monstrey, S
2016-11-01
For more than 40 years, silver sulphadiazine 1% (SSD) is considered as standard therapy for the conservative treatment of burn wounds. However, in the last 10 years, substantial disadvantages of SSD have been reported in the literature and probably as a result of this, several new dressings for burn wounds have been developed and put on the market. The objective of this systematic review is to evaluate the available evidence on SSD in the conservative treatment of burns, specifically in comparison with the newer burn dressings that are increasingly being used nowadays. A search filter was composed to select randomized controlled trials (RCTs) from the MEDLINE database. Only RCTs studying the effect of conservative treatment on burns were selected. At least one of the two comparative groups was treated with SSD. Each included article was analysed and relevant data (baseline parameters, interventions, outcomes and methodological parameters) were registered using Microsoft Office Excel 2007. Many dressings showed superior healing properties compared to SSD, but no dressing was able to show a clear benefit over SSD regarding infection. The number of dressing changes, pain and patient's satisfaction are more favourable in the newer dressings, especially with solid and biological dressings. The results of this systematic review clearly demonstrate that a faster wound healing is obtained with the newly developed burn dressings. Additionally, these new dressings tend to be more comfortable for the patients and easier to use for care givers. The minor differences in antibacterial activity between SSD and the new products did not seem to have any influence on the rate of wound healing. Since rapid wound closure is essential to obtain an optimal functional and aesthetic outcome, it can be concluded from the results of this systemic review that the standard use of SSD in the conservative treatment of burn wounds can no longer be supported. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
A PEGylated Fibrin-Based Wound Dressing with Antimicrobial and Angiogenic Activity
2011-04-13
naturally available, cost-effective, biocompatible, and biodegradable. Among these natural polymers chitosan ( poly (b-(1,4)-2-amino-2-deoxy-D...drying, ionic gela- tion, and sieving. Among these, ionic gelation is preferred for drugs that require an initial short burst release while maintaining...form ionic interactions with anionic mole- cules, and have been previously used for the controlled release of drugs [18]. Since SSD is a weak anionic
Dynamical Casimir-Polder force on a partially dressed atom near a conducting wall
DOE Office of Scientific and Technical Information (OSTI.GOV)
Messina, Riccardo; Vasile, Ruggero; Passante, Roberto
2010-12-15
We study the time evolution of the Casimir-Polder force acting on a neutral atom in front of a perfectly conducting plate, when the system starts its unitary evolution from a partially dressed state. We solve the Heisenberg equations for both atomic and field quantum operators, exploiting a series expansion with respect to the electric charge and an iterative technique. After discussing the behavior of the time-dependent force on an initially partially dressed atom, we analyze a possible experimental scheme to prepare the partially dressed state and the observability of this new dynamical effect.
Hasatsri, Sukhontha; Angspatt, Apichai
2015-01-01
We developed the novel silk fibroin-based bilayered wound dressing for the treatment of partial thickness wounds. And it showed relevant characteristics and accelerated the healing of full-thickness wounds in a rat model. This study is the clinical evaluation of the bilayered wound dressing to confirm its safety and efficacy for the treatment of split-thickness skin donor sites. The safety test was performed using a patch model and no evidence of marked and severe cutaneous reactions was found. The efficacy test of the bilayered wound dressing was conducted on 23 patients with 30 split-thickness skin graft donor sites to evaluate healing time, pain score, skin barrier function, and systemic reaction in comparison to Bactigras. We found that the healing time of donor site wounds treated with the bilayered wound dressing (11 ± 6 days) was significantly faster than those treated with Bactigras (14 ± 6 days) (p = 10−6). The wound sites treated with the bilayered wound dressing showed significantly less pain and more rapid skin functional barrier recovery than those treated with Bactigras (p = 10−5). Therefore, these results confirmed the clinical safety and efficacy of the bilayered wound dressing for the treatment of split-thickness skin graft donor sites. PMID:26221170
Economic impact of Tegaderm chlorhexidine gluconate (CHG) dressing in critically ill patients.
Thokala, Praveen; Arrowsmith, Martin; Poku, Edith; Martyn-St James, Marissa; Anderson, Jeff; Foster, Steve; Elliott, Tom; Whitehouse, Tony
2016-09-01
To estimate the economic impact of a Tegaderm TM chlorhexidine gluconate (CHG) gel dressing compared with a standard intravenous (i.v.) dressing (defined as non-antimicrobial transparent film dressing), used for insertion site care of short-term central venous and arterial catheters (intravascular catheters) in adult critical care patients using a cost-consequence model populated with data from published sources. A decision analytical cost-consequence model was developed which assigned each patient with an indwelling intravascular catheter and a standard dressing, a baseline risk of associated dermatitis, local infection at the catheter insertion site and catheter-related bloodstream infections (CRBSI), estimated from published secondary sources. The risks of these events for patients with a Tegaderm CHG were estimated by applying the effectiveness parameters from the clinical review to the baseline risks. Costs were accrued through costs of intervention (i.e. Tegaderm CHG or standard intravenous dressing) and hospital treatment costs depended on whether the patients had local dermatitis, local infection or CRBSI. Total costs were estimated as mean values of 10,000 probabilistic sensitivity analysis (PSA) runs. Tegaderm CHG resulted in an average cost-saving of £77 per patient in an intensive care unit. Tegaderm CHG also has a 98.5% probability of being cost-saving compared to standard i.v. dressings. The analyses suggest that Tegaderm CHG is a cost-saving strategy to reduce CRBSI and the results were robust to sensitivity analyses.
Silver deposition and tissue staining associated with wound dressings containing silver.
Walker, Michael; Cochrane, Christine A; Bowler, Philip G; Parsons, David; Bradshaw, Peter
2006-01-01
Argyria is the general term used to denote a clinical condition in which excessive administration and deposition of silver causes a permanent irreversible gray-blue discoloration of the skin or mucous membranes. The amount of discoloration usually depends on the route of silver delivery (ie, oral or topical administration) along with the body's ability to absorb and excrete the administered silver compound. Argyria is accepted as a rare dermatosis but once silver particles are deposited, they remain immobile and may accumulate during the aging process. Topical application of silver salts (eg, silver nitrate solution) may lead to transient skin staining. To investigate their potential to cause skin staining, two silver-containing dressings (Hydrofiber and nanocrystalline) were applied to human skin samples taken from electively amputated lower limbs. The potential for skin discoloration was assayed using atomic absorption spectroscopy. When the dressings were hydrated with water, a significantly higher amount of silver was released from the nanocrystalline dressing compared to the Hydrofiber dressing (P <0.005), which resulted in approximately 30 times more silver deposition. In contrast, when saline was used as the hydration medium, the release rates were low for both dressings and not significantly different (silver deposition was minimal). Controlling the amount of silver released from silver-containing dressings should help reduce excessive deposition of silver into wound tissue and minimize skin staining.
Anjum, Sadiya; Gupta, Amlan; Sharma, Deepika; Gautam, Deepti; Bhan, Surya; Sharma, Anupama; Kapil, Arti; Gupta, Bhuvanesh
2016-07-01
This study is aimed at the development of a composite material for wound dressing containing nanosilver nanohydrogels (nSnH) along with Aloe vera and curcumin that promote antimicrobial nature, wound healing and infection control. Nanosliver nanohydrogels were synthesized by nanoemulsion polymerization of methacrylic acid (MAA) followed by subsequent crosslinking and silver reduction under irradiation. Both the polymerization and irradiation time had significant influence on the nanoparticle shape, size and its formation. Polyvinyl alcohol/polyethylene oxide/carboxymethyl cellulose matrix was used as gel system to blend with nSnH, A. vera, curcumin and coat it on the hydrolysed PET fabric to develop antimicrobial dressings. The cumulative release of silver from the dressing was found to be ~42% of the total loading after 48h. The antimicrobial activity of the dressings was studied against both Staphylococcus aureus and Escherichia coli. In vivo wound healing studies were carried out over a period of 16d on full-thickness skin wounds created on Swiss albino mice. Fast healing was observed in Gel/nSnH/Aloe treated wounds with minimum scarring, as compared to other groups. The histological studies showed A. vera based dressings to be the most optimum one. These results suggest that nSnH along with A. vera based dressing material could be promising candidates for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.
Spatial filtering, color constancy, and the color-changing dress.
Dixon, Erica L; Shapiro, Arthur G
2017-03-01
The color-changing dress is a 2015 Internet phenomenon in which the colors in a picture of a dress are reported as blue-black by some observers and white-gold by others. The standard explanation is that observers make different inferences about the lighting (is the dress in shadow or bright yellow light?); based on these inferences, observers make a best guess about the reflectance of the dress. The assumption underlying this explanation is that reflectance is the key to color constancy because reflectance alone remains invariant under changes in lighting conditions. Here, we demonstrate an alternative type of invariance across illumination conditions: An object that appears to vary in color under blue, white, or yellow illumination does not change color in the high spatial frequency region. A first approximation to color constancy can therefore be accomplished by a high-pass filter that retains enough low spatial frequency content so as to not to completely desaturate the object. We demonstrate the implications of this idea on the Rubik's cube illusion; on a shirt placed under white, yellow, and blue illuminants; and on spatially filtered images of the dress. We hypothesize that observer perceptions of the dress's color vary because of individual differences in how the visual system extracts high and low spatial frequency color content from the environment, and we demonstrate cross-group differences in average sensitivity to low spatial frequency patterns.
Gharibi, Reza; Yeganeh, Hamid; Rezapour-Lactoee, Alireza; Hassan, Zuhair M
2015-11-04
A series of novel polyurethane/siloxane-based wound dressing membranes was prepared through sol-gel reaction of methoxysilane end-functionalized urethane prepolymers composed of castor oil and ricinoleic methyl ester as well as methoxysilane functional aniline tetramer (AT) moieties. The samples were fully characterized and their physicochemical, mechanical, electrical, and biological properties were assayed. The biological activity of these dressings against fibroblast cells and couple of microbes was also studied. It was revealed that samples that displayed electroactivity by introduction of AT moieties showed a broad range of antimicrobial activity toward different microorganisms, promising antioxidant (radical scavenging) efficiency and significant activity for stimulation of fibroblast cell growth and proliferation. Meanwhile, these samples showed appropriate tensile strength and ability for maintaining a moist environment over a wound by controlled equilibrium water absorption and water vapor transmission rate. The selected electroactive dressing was subjected to an in vivo assay using a rat animal model and the wound healing process was monitored and compared with analogous dressing without AT moieties. The recorded results showed that the electroactive dressings induced an increase in the rate of wound contraction, promoted collagen deposition, and encouraged vascularization in the wounded area. On the basis of the results of in vitro and in vivo assays, the positive influence of designed dressings for accelerated healing of a wound model was confirmed.
Placing the patient at the centre of chronic wound care: A qualitative evidence synthesis.
Fearns, Naomi; Heller-Murphy, Stephen; Kelly, Joanna; Harbour, Jenny
2017-11-01
Chronic wounds are a major health burden and have a severe impact on well-being. This synthesis of qualitative studies was undertaken to inform a health technology assessment of antimicrobial wound dressings. It aimed to explore patients' experiences of chronic wounds and determine improvements for clinical practice. Inclusion criteria included use of qualitative methods, and English language publication. Databases searched included MEDLINE (Ovid), MEDLINE in Process (Ovid), EMBASE (Ovid), CINAHL (EBSCOHost), and PsychInfo (EBSCOHost). Searches were limited to 1990-2014. The method of analysis was Framework synthesis. A total of 20 studies were included. The synthesis confirmed the severe physical, social and psychological impact of the chronic wound. Inadequately controlled pain and sleeplessness, restrictions to lifestyle, and the loss of previous life roles can lead to feelings of hopelessness and helplessness and therefore depression and anxiety. Dressings and dressing changes are a key aspect of treatment and provide opportunities for positive interaction and person centred-care. People with chronic wounds can be supported to live well within the severe physical, psychological and social restrictions of a chronic wound. Effective clinical pain management and the recognition of the experience of acute and chronic pain are of the utmost importance to people with a chronic wound. Treatment should not be purely focused on healing but incorporate symptom management, coping and wellbeing via person-centred and holistic care. Copyright © 2017 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
De Marchi, João Guilherme B; Jornada, Denise S; Silva, Fernanda K; Freitas, Ana L; Fuentefria, Alexandre M; Pohlmann, Adriana R; Guterres, Silvia S
2017-01-01
The use of nanoparticles may be particularly advantageous in treating bacterial infections due to their multiple simultaneous mechanisms of action. Nanoencapsulation is particularly useful for lipophilic drugs. In this scenario, triclosan is considered a good candidate due to its lipophilicity, broad-spectrum activity, and safety. In the present study, we have developed and characterized an antimicrobial suspension of triclosan and α-bisabolol against pathogenic strains that are resistant (Pseudomonas aeruginosa) and susceptible (Escherichia coli, Staphylococcus aureus, and Candida albicans) to triclosan. We also aimed to determine the minimum inhibitory concentration, using serial microdilution adapted from a CLSI methodology (Clinical and Laboratory Standards Institute). Challenge test was used to confirm the antimicrobial effectiveness of the nanocapsule formulation, as well as after its incorporation into a commercial wound dressing (Veloderm®). The zeta potential of P. aeruginosa before and after contact with cationic nanocapsules and the ratio between the number of nanocapsules per colony forming unit (CFU) were determined to evaluate a possible interaction between nanocapsules and bacteria. The results showed that nanoencapsulation has improved the antimicrobial activity when tested with two different methodologies. The number of nanocapsules per CFU was high even in great dilutions and the zeta potential was reverted after being in contact with the cationic nanocapsules. The nanocapsules were able to improve the activity of triclosan, even when tested within 28 days and when dried in the wound dressing. PMID:29123398
NASA Astrophysics Data System (ADS)
Kenkre, V. M.; Ierides, A. A.
2018-06-01
This theoretical study of the vibrational relaxation of a molecule in interaction with a reservoir uncovers a noteworthy temperature (T) dependence of the time evolution of the relaxation. Its rate increases with T in one interval but decreases in another. The feature arises not for a weak molecule-reservoir interaction but only for coupling strong enough to require polaronic dressing transformations. Our treatment, based on a recent generalization of the well-known Montroll-Shuler equation for relaxation and an explicit calculation of bath correlations from the microscopically specified Hamiltonian, could provide an alternative explanation of an "inverted" T-dependence of relaxation in an experimental report by Fayer and collaborators on W(CO)6 dissolved in CHCl3.
The puzzle of bakanae disease through interactions between Fusarium fujikuroi and rice.
Matic, Slavica; Gullino, Maria L; Spadaro, Davide
2017-06-01
Bakanae disease, one of the most noteworthy seedborne rice diseases, is caused by Fusarium fujikuroi, a member of the Gibberella fujikuroi species complex. The decreasing availability of chemical seed-dressing products over the last few years has raised the concerns of rice seed companies regarding bakanae disease. Therefore, new research trends require a deeper investigation into the main aspects of bakanae disease through interactions between rice and F. fujikuroi, in order to find new resistant or tolerant cultivars and alternative bakanae disease control strategies, as well as to develop more sensitive molecular diagnostic techniques. Here, some new aspects of F. fujikuroi epidemiology and pathogenicity, as well as its interactions with rice, are reported, and recent approaches applied to control bakanae disease are summarized.
Beyond BCS pairing in high-density neutron matter
NASA Astrophysics Data System (ADS)
Rios, A.; Ding, D.; Dussan, H.; Dickhoff, W. H.; Witte, S. J.; Polls, A.
2018-01-01
Pairing gaps in neutron matter need to be computed in a wide range of densities to address open questions in neutron star phenomenology. Traditionally, the Bardeen-Cooper-Schrieffer approach has been used to compute gaps from bare nucleon-nucleon interactions. Here, we incorporate the influence of short- and long-range correlations into pairing properties. Short-range correlations are treated including the appropriate fragmentation of single-particle states, and they suppress the gaps substantially. Long-range correlations dress the pairing interaction via density and spin modes, and provide a relatively small correction. We use three different interactions as a starting point to control for any systematic effects. Results are relevant for neutron-star cooling scenarios, in particular in view of the recent observational data on Cassiopeia A.
Civil Behavior, Safe-School Planning, and Dress Codes
ERIC Educational Resources Information Center
Studak, Cathryn M.; Workman, Jane E.
2007-01-01
This research examined news reports in order to identify incidents that precipitated dress code revisions. News reports were examined within the framework of rules for civil behavior. Using key words "school dress codes" and "violence," LEXIS/NEXIS was used to access 104 articles from 44 U.S. newspapers from December 3, 2004 to December 2, 2005.…
Cross Dressing and Gender Dysphoria in People with Learning Disabilities: A Descriptive Study
ERIC Educational Resources Information Center
Parkes, Georgina; Hall, Ian; Wilson, Daniel
2009-01-01
We aimed to determine the characteristics of people with learning disability who cross-dress or who have gender dysphoria. Using a retrospective review of anonymised data from clinical records about people referred to a specialist service. All 13 participants cross-dressed and 12 were biological males. Only one person was in a core transsexual…
Rural School District Dress Code Implementation: Perceptions of Stakeholders after First Year
ERIC Educational Resources Information Center
Wright, Krystal M.
2012-01-01
Schools are continuously searching for solutions to solve truancy, academic, behavioral, safety, and climate issues. One of the latest trends in education is requiring students to adhere to dress codes as a solution to these issues. Dress codes can range from slightly restrictive clothing to the requiring of a uniform. Many school district…
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
21 CFR 878.4015 - Wound dressing with poly (diallyl dimethyl ammonium chloride) (pDADMAC) additive.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ammonium chloride) (pDADMAC) additive. 878.4015 Section 878.4015 Food and Drugs FOOD AND DRUG...) additive. (a) Identification. A wound dressing with pDADMAC additive is intended for use as a primary... Dressing With Poly (Diallyl Dimethyl Ammonium Chloride) (pDADMAC) Additive.” See § 878.1(e) for...
Effect of Most-to-Least Prompting Procedure on Dressing Skill of Students with Autism
ERIC Educational Resources Information Center
Çetrez-Iscan, Galibiye; Nurçin, Elçin; Fazlioglu, Yesim
2016-01-01
Dressing skill is one of the necessary self-care skills that is taught to individuals with autism in order for them to be able to live independently. Typically, developing individuals can acquire dressing skill on their own; however, children with autism have difficulties in learning such skill without systematic teaching. Thus, teaching dressing…
Davies, Phil
2016-01-01
Despite the implementation of prevention strategies, pressure ulcers (PUs) continue to be a challenging health problem for patients (and their carers), clinicians and health-care providers. One area of growing interest is the use of prophylactic dressings (which were originally designed for the treatment of PUs and other wound types) as a component of standard prevention measures. Over the past few years, a large amount of scientific and clinical data relating to this subject has been published in peer-reviewed journals and presented at international meetings and conferences. A substantial proportion of these data relate to one group of dressings: multi-layer foam dressings with Safetac, which are manufactured by Mölnlycke Health Care (Gothenburg, Sweden). This evidence pool has influenced the experts involved in updating the Clinical Practice Guideline, produced by the National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance, on the prevention and treatment of PUs. The updated Guideline, published in 2014, recommends that, as part of their PU prevention regimens, clinicians should consider applying prophylactic dressings to bony prominences in anatomical areas that are frequently subjected to friction and shear. A literature review was undertaken to identify clinical data from the entire evidence hierarchy, as well as scientific data from laboratory studies, on the use of multi-layer foam dressings with Safetac in the prevention of pressure ulceration. The MEDLINE (National Library of Medicine, Bethesda, US) and EMBASE (Elsevier B, Amsterdam, Netherlands) bibliographic databases were searched. In addition, abstract books and proceedings documents relating to national and international conferences were scanned in order to identify presentations (i.e. oral, e-posters and posters) of relevance to the review. Clinical and health economic experts have undertaken numerous studies, including randomised controlled trials, to assess the efficacy and cost-effectiveness of using multi-layer foam dressings with Safetac as a component of standard PU prevention strategies. The results of these studies indicate that the application of multi-layer foam dressings containing Safetac can reduce the occurrence of PUs on anatomical locations such as the sacrum and the heel, and underneath medical devices. Scientists have also developed and used laboratory methods to gain a better understanding of how prophylactic dressings work. The results of these studies indicate that the composition of foam dressings containing Safetac (i.e. their multi-layer structure) sets them apart from other dressings due to their ability to mediate the effects of physical forces (i.e. pressure, friction and shear) and control microclimate, all of which contribute to pressure ulceration. The evidence pool clearly indicates that the prophylactic use of multi-layer foam dressings with Safetac as a component of standard prevention measures is beneficial to the clinician, the health-care provider and the patient. It should be noted that the findings outlined in this review may not be transferable to other products as their makeup and components are likely to differ significantly from those of multi-layer foam dressings with Safetac. As the importance of evidence-based practice and the need for cost-effective care continues to grow, clinicians and provider should carefully consider this point when selecting prophylactic dressings for PU prevention.
Santamaria, N; Gerdtz, M; Liu, W; Rakis, S; Sage, S; Ng, A W; Tudor, H; McCann, J; Vassiliou, T; Morrow, F; Smith, K; Knott, J; Liew, D
2015-08-01
Critically ill patients are at high risk of developing pressure ulcers (PU), with the sacrum and heels being highly susceptible to pressure injuries. The objective of our study was to evaluate the clinical effectiveness of a new multi-layer, self-adhesive soft silicone foam heel dressing to prevent PU development in trauma and critically ill patients in the intensive care unit (ICU). A cohort of critically ill patients were enrolled at the Royal Melbourne Hospital. Each patient had the multi-layer soft silicone foam dressing applied to each heel on admission to the emergency department. The dressings were retained with a tubular bandage for the duration of the patients' stay in the ICU. The skin under the dressings was examined daily and the dressings were replaced every three days. The comparator for our cohort study was the control group from the recently completed Border Trial. Of the 191 patients in the initial cohort, excluding deaths, loss to follow-up and transfers to another ward, 150 patients were included in the final analysis. There was no difference in key demographic or physiological variables between the cohorts, apart from a longer ICU length of stay for our current cohort. No PUs developed in any of our intervention cohort patients compared with 14 patients in the control cohort (n=152; p<0.001) who developed a total of 19 heel PUs. We conclude, based on our results, that the multi-layer soft silicone foam dressing under investigation was clinically effective in reducing ICU-acquired heel PUs. The findings also support previous research on the clinical effectiveness of multi-layer soft silicone foam dressings for PU prevention in the ICU.
The analytic structure of non-global logarithms: Convergence of the dressed gluon expansion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larkoski, Andrew J.; Moult, Ian; Neill, Duff Austin
Non-global logarithms (NGLs) are the leading manifestation of correlations between distinct phase space regions in QCD and gauge theories and have proven a challenge to understand using traditional resummation techniques. Recently, the dressed gluon ex-pansion was introduced that enables an expansion of the NGL series in terms of a “dressed gluon” building block, defined by an all-orders factorization theorem. Here, we clarify the nature of the dressed gluon expansion, and prove that it has an infinite radius of convergence as a solution to the leading logarithmic and large-N c master equation for NGLs, the Banfi-Marchesini-Smye (BMS) equation. The dressed gluonmore » expansion therefore provides an expansion of the NGL series that can be truncated at any order, with reliable uncertainty estimates. In contrast, manifest in the results of the fixed-order expansion of the BMS equation up to 12-loops is a breakdown of convergence at a finite value of α slog. We explain this finite radius of convergence using the dressed gluon expansion, showing how the dynamics of the buffer region, a region of phase space near the boundary of the jet that was identified in early studies of NGLs, leads to large contributions to the fixed order expansion. We also use the dressed gluon expansion to discuss the convergence of the next-to-leading NGL series, and the role of collinear logarithms that appear at this order. Finally, we show how an understanding of the analytic behavior obtained from the dressed gluon expansion allows us to improve the fixed order NGL series using conformal transformations to extend the domain of analyticity. Furthermore, this allows us to calculate the NGL distribution for all values of α slog from the coefficients of the fixed order expansion.« less
Fischer, Sebastian; Wall, Jennifer; Pomahac, Bohdan; Riviello, Robert; Halvorson, Eric G
2016-03-01
The use of negative-pressure-wound-therapy (NPWT) is associated with improved outcomes in smaller burns. We report our experience using extra-large (XL) NPWT dressings to treat ≥15% total body surface area (TBSA) burned and describe our technique and early outcomes. We also provide NPWT exudate volume for predictive fluid resuscitation in these critically ill patients. We retrospectively reviewed patients treated with XL-NPWT from 2012 to 2014. Following excision/grafting, graft and donor sites were sealed with a layered NPWT dressing. We documented wound size, dressing size, NPWT outputs, graft take, wound infections, and length of stay (LOS). Mean NPWT exudate volume per %TBSA per day was calculated. Twelve burn patients (mean TBSA burned 30%, range 15-60%) were treated with XL-NPWT (dressing TBSA burned and skin graft donor sites range 17-44%). Average graft take was 97%. No wound infections occurred. Two patients had burns ≥50% TBSA and their LOS was reduced compared to ABA averages. XL-NPWT outputs peaked at day 1 after grafting followed by a steady decline until dressings were removed. Average XL-NPWT dressing output during the first 5 days was 101±66mL/%BSA covered per day. 2 patients developed acute kidney injury. The use of XL-NPWT to treat extensive burns is feasible with attention to application technique. NPWT dressings appear to improve graft take, and to decrease risk of infection, LOS, and pain and anxiety associated with wound care. Measured fluid losses can improve patient care in future applications of NPWT to large burn wounds. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Mahoney, Diane Feeney; Coon, David W; Lozano, Cecil
2016-11-01
To gain an understanding of Latino/Hispanic caregivers' dementia-related dressing issues, their impressions of using a "smart" context-aware dresser to coach dressing, and recommendations to improve its acceptability. The same Latina moderator conducted all the caregiver focus groups. She followed a semi-structured interview guide that was previously used with White and African American family caregivers who experienced Alzheimer's disease related dressing challenges. From that study, the Preservation of Self model emerged. Using a deductive qualitative analytic approach, we applied the thematic domains from the Preservation of Self model to ascertain relevance to Latino/Hispanic caregivers. Twenty Latino/Hispanic experienced caregivers were recruited, enrolled, and participated in one of three focus groups. The majority were female (75%) and either the spouse (25%) or adult child (35%). Striking similarities occurred with the dressing challenges and alignment with the Preservation of Self model. Ethnic differences arose in concerns over assimilation weakening the Latino culture of family caregiving. Regional clothing preferences were noted. Technology improvement recommendations for our system, called DRESS, included developing bilingual prompting dialogs and video modules using the local vernacular to improve cultural sensitivity. Caregivers identified the potential for the technology to enable user privacy, empowerment, and exercise as well as offering respite time for themselves. Findings suggest dementia-related dressing issues were shared in common by different racial/ethnic groups but the response to them was influenced by cultural dynamics. For the first time Latino/Hispanic voices are heard to reflect their positive technology impressions, concerns, and recommendations in order to begin to address the cultural digital disparities divide.
Mahoney, Diane Feeney; Coon, David W; Lozano, Cecil
2016-01-01
Objective To gain an understanding of Latino/Hispanic caregivers’ dementia-related dressing issues, their impressions of using a “smart” context-aware dresser to coach dressing, and recommendations to improve its acceptability. Method The same Latina moderator conducted all the caregiver focus groups. She followed a semi-structured interview guide that was previously used with White and African American family caregivers who experienced Alzheimer’s disease related dressing challenges. From that study, the Preservation of Self model emerged. Using a deductive qualitative analytic approach, we applied the thematic domains from the Preservation of Self model to ascertain relevance to Latino/Hispanic caregivers. Results Twenty Latino/Hispanic experienced caregivers were recruited, enrolled, and participated in one of three focus groups. The majority were female (75%) and either the spouse (25%) or adult child (35%). Striking similarities occurred with the dressing challenges and alignment with the Preservation of Self model. Ethnic differences arose in concerns over assimilation weakening the Latino culture of family caregiving. Regional clothing preferences were noted. Technology improvement recommendations for our system, called DRESS, included developing bilingual prompting dialogs and video modules using the local vernacular to improve cultural sensitivity. Caregivers identified the potential for the technology to enable user privacy, empowerment, and exercise as well as offering respite time for themselves. Conclusion Findings suggest dementia-related dressing issues were shared in common by different racial/ethnic groups but the response to them was influenced by cultural dynamics. For the first time Latino/Hispanic voices are heard to reflect their positive technology impressions, concerns, and recommendations in order to begin to address the cultural digital disparities divide.
Walker, Michael; Bowler, Philip G; Cochrane, Christine A
2007-09-01
Excess or "uncontrolled" proteinase activity in the wound bed has been implicated as one factor that may delay or compromise wound healing. One proteinase group--matrix metalloproteinases--includes collagenases, elastase, and gelatinases and can be endogenous (cell) or exogenous (bacterial) in origin. A study was conducted to assess the ability of five silver-containing wound care products to reduce a known matrix metalloproteinase supernatant concentration in vitro. Four silver-containing wound dressings (a carboxy-methyl cellulose, a nanocrystalline, a hydro-alginate, and a collagen/oxidized regenerated cellulose composite dressing), along with a 0.5% aqueous silver nitrate [w/v] solution and controls for matrix metalloproteinase-2 and matrix metalloproteinase-9 sourced from ex vivo dermal tissue and blood monocytes, respectively, were used. Extracts were separated and purified using gelatine-Sepharose column chromatography and dialysis and polyacrylamide gel electrophoretic zymography was used to analyze specific matrix metalloproteinase activity. All dressings and the solution were shown to sequester both matrix metalloproteinases. The silver-containing carboxy-methyl cellulose dressing showed significantly greater sequestration for matrix metalloproteinase-2 at 6 and 24 hours (P< 0.001) compared to the other treatments. For matrix metalloproteinase-9, both the carboxy-methyl cellulose dressing and the oxidized regenerated cellulose dressing achieved significant sequestration when compared to the other treatments at 24 hours (P <0.001), which was maintained to 48 hours (P < 0.001). Results from this study show that silver-containing dressings are effective in sequestering matrix metalloproteinase-2 and -9 and that this can be achieved without a sacrificial protein (eg, collagen). Although the varying ability of wound dressings to sequester matrix metalloproteinases has been shown in vitro, further in vivo evidence is required to confirm these findings.
Management of Psychotropic Drug-Induced DRESS Syndrome: A Systematic Review.
Bommersbach, Tanner J; Lapid, Maria I; Leung, Jonathan G; Cunningham, Julie L; Rummans, Teresa A; Kung, Simon
2016-06-01
Drug rash with eosinophilia and systemic symptoms (DRESS) is a severe cutaneous eruption that has been linked to several common drugs and drug categories, including antiepileptics, allopurinol, sulfonamides, and various antibiotics; however, because of a number of recent case reports linking psychotropic medications to this condition, DRESS is increasingly recognized among psychiatrists. We systematically reviewed all psychotropic drugs linked to DRESS syndrome, and this article summarizes the clinical management relevant to psychiatric professionals. A comprehensive search was performed using Ovid MEDLINE, Ovid EMBASE, Ovid Cochrane Database of Systematic Reviews, Web of Science, Scopus, and Litt's Drug Eruption and Reaction Database for articles published in English during the past 20 years (1996-2015) using the search terms (1) psychotropic drugs OR serotonin uptake inhibitors AND DRESS or (2) psychotropic drugs AND drug reaction (or rash) eosinophilia systemic syndrome, and all article abstracts were screened for inclusion and exclusion criteria by 3 reviewers. Two independent reviewers examined the full text of 163 articles, of which 96 (25 original articles, 12 review articles, 55 case reports, and 4 letters to the editor) were included in the systematic review. We identified 1072 cases of psychotropic drug-induced DRESS, with carbamazepine, lamotrigine, phenytoin, valproate, and phenobarbital being the most implicated drugs. Based on our review of the literature, we outline management principles that include prompt withdrawal of the causative drug, hospitalization, corticosteroid therapy, and novel treatments, including intravenous immunoglobulin, cyclophosphamide, and cyclosporine, for corticosteroid-resistant DRESS. Finally, we outline strategies for treating comorbid psychiatric illness after a DRESS reaction to the psychotropic medication. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Karlsson, Bodil S A; Allwood, Carl Martin
2016-01-01
The Dress photograph, first displayed on the internet in 2015, revealed stunning individual differences in color perception. The aim of this study was to investigate if lay-persons believed that the question about The Dress colors was answerable. Past research has found that optimism is related to judgments of how answerable knowledge questions with controversial answers are (Karlsson et al., 2016). Furthermore, familiarity with a question can create a feeling of knowing the answer (Reder and Ritter, 1992). Building on these findings, 186 participants saw the photo of The Dress and were asked about the correct answer to the question about The Dress' colors (" blue and black," "white and gold," "other, namely…," or "there is no correct answer" ). Choice of the alternative "there is no correct answer" was interpreted as believing the question was not answerable. This answer was chosen more often by optimists and by people who reported they had not seen The Dress before. We also found that among participants who had seen The Dress photo before, 19%, perceived The Dress as "white and gold" but believed that the correct answer was "blue and black ." This, in analogy to previous findings about non-believed memories (Scoboria and Pascal, 2016), shows that people sometimes do not believe the colors they have perceived are correct. Our results suggest that individual differences related to optimism and previous experience may contribute to if the judgment of the individual perception of a photograph is enough to serve as a decision basis for valid conclusions about colors. Further research about color judgments under ambiguous circumstances could benefit from separating individual perceptual experience from beliefs about the correct answer to the color question. Including the option "there is no correct answer " may also be beneficial.
The analytic structure of non-global logarithms: Convergence of the dressed gluon expansion
Larkoski, Andrew J.; Moult, Ian; Neill, Duff Austin
2016-11-15
Non-global logarithms (NGLs) are the leading manifestation of correlations between distinct phase space regions in QCD and gauge theories and have proven a challenge to understand using traditional resummation techniques. Recently, the dressed gluon ex-pansion was introduced that enables an expansion of the NGL series in terms of a “dressed gluon” building block, defined by an all-orders factorization theorem. Here, we clarify the nature of the dressed gluon expansion, and prove that it has an infinite radius of convergence as a solution to the leading logarithmic and large-N c master equation for NGLs, the Banfi-Marchesini-Smye (BMS) equation. The dressed gluonmore » expansion therefore provides an expansion of the NGL series that can be truncated at any order, with reliable uncertainty estimates. In contrast, manifest in the results of the fixed-order expansion of the BMS equation up to 12-loops is a breakdown of convergence at a finite value of α slog. We explain this finite radius of convergence using the dressed gluon expansion, showing how the dynamics of the buffer region, a region of phase space near the boundary of the jet that was identified in early studies of NGLs, leads to large contributions to the fixed order expansion. We also use the dressed gluon expansion to discuss the convergence of the next-to-leading NGL series, and the role of collinear logarithms that appear at this order. Finally, we show how an understanding of the analytic behavior obtained from the dressed gluon expansion allows us to improve the fixed order NGL series using conformal transformations to extend the domain of analyticity. Furthermore, this allows us to calculate the NGL distribution for all values of α slog from the coefficients of the fixed order expansion.« less
Hierarchy of Dysfunction Related to Dressing Performance in Stroke Patients: A Path Analysis Study.
Fujita, Takaaki; Nagayama, Hirofumi; Sato, Atsushi; Yamamoto, Yuichi; Yamane, Kazuhiro; Otsuki, Koji; Tsuchiya, Kenji; Tozato, Fusae
2016-01-01
Previous reports indicated that various dysfunctions caused by stroke affect the level of independence in dressing. These dysfunctions can be hierarchical, and these effects on dressing performance can be complicated in stroke patients. However, there are no published reports focusing on the hierarchical structure of the relationships between the activities of daily living and balance function, motor and sensory functions of the affected lower limb, strength of the abdominal muscles and knee extension on the unaffected side, and visuospatial deficits. The purpose of this study was to elucidate the hierarchical and causal relationships between dressing performance and these dysfunctions in stroke patients. This retrospective study included 104 first-time stroke patients. The causal relationship between the dressing performance and age, time post stroke, balance function, motor and sensory functions of the affected lower limb, strength of the abdominal muscles and knee extension on the unaffected side, and visuospatial deficits were examined using path analysis. A hypothetical path model was created based on previous studies, and the goodness of fit between the data and model were verified. A modified path model was created that achieved an almost perfect fit to the data. Balance function and abdominal muscle strength have direct effects on dressing performance, with standardized direct effect estimates of 0.78 and 0.15, respectively. Age, motor and sensory functions of the affected lower limb, and strength of abdominal muscle and knee extension on the unaffected side have indirect effects on dressing by influencing balance function. Our results suggest that dressing performance depends strongly on balance function, and it is mainly influenced by the motor function of the affected lower limb.
Bikmoradi, Ali; Harorani, Mehdi; Roshanaei, Ghodratollah; Moradkhani, Shirin; Falahinia, Golam Hossein
2016-01-01
Background: Pain is one of the common problems encountered by patients with burns, which increases after each dressing. This study aimed to investigate the effect of inhalation aromatherapy with damask rose essence on the pain of patients with burns that is caused after dressing. Materials and Methods: A randomized clinical trial was conducted on 50 patients with second- and third-degree burn wounds. The baseline pain of the patients was assessed 30 min before they entered into the dressing room on the first and second days of intervention. The patients in the experimental group inhaled five drops of damask rose essence 40% in distilled water, while those in the control group inhaled five drops of distilled water as placebo. The pain intensity was assessed using Visual Analogue Scale at 15 and 30 min after the patients exited from the dressing room. Data were analyzed by SPSS (version 18) using descriptive and inferential statistics. Results: There was significant difference between the mean of pain intensity before and after intervention at 15 and 30 min after dressing (P < 0.001). Moreover, there was significant difference in reduction of pain intensity before and after aromatherapy in the experimental group (P < 0.05). Also, there was a significant reduction in severity of pain after dressing in the experimental group compared with the control group (P < 0.05). Conclusions: Inhalation aromatherapy with damask rose could be effective for relieving the pain caused after dressing in patients with burns. Therefore, it could be suggested as a complementary therapy in burn patients for pain relief. PMID:27186201
A dressed spin qubit in silicon
Laucht, Arne; Kalra, Rachpon; Simmons, Stephanie; ...
2016-10-17
Coherent dressing of a quantum two-level system provides access to a new quantum system with improved properties—a different and easily tunable level splitting, faster control and longer coherence times. In our work we investigate the properties of the dressed, donor-bound electron spin in silicon, and assess its potential as a quantum bit in scalable architectures. The two dressed spin-polariton levels constitute a quantum bit that can be coherently driven with an oscillating magnetic field, an oscillating electric field, frequency modulation of the driving field or a simple detuning pulse. We measure coherence times of T* 2p = 2.4 ms andmore » T Hahn 2p = 9 ms, one order of magnitude longer than those of the undressed spin. Moreover, the use of the dressed states enables coherent coupling of the solid-state spins to electric fields and mechanical oscillations.« less
Control of traumatic wound bleeding by compression with a compact elastic adhesive dressing.
Naimer, Sody Abby; Tanami, Menachem; Malichi, Avishai; Moryosef, David
2006-07-01
Compression dressing has been assumed effective, but never formally examined in the field. A prospective interventional trial examined efficacy and feasibility of an elastic adhesive dressing compression device in the arena of the traumatic incident. The primary variable examined was the bleeding rate from wounds compared before and after dressing. Sixty-two consecutive bleeding wounds resulting from penetrating trauma were treated. Bleeding intensity was profuse in 58%, moderate 23%, and mild in 19%. Full control of bleeding was achieved in 87%, a significantly diminished rate in 11%, and, in 1 case, the technique had no influence on the bleeding rate. The Wilcoxon test for variables comparing bleeding rates before and after the procedure obtained significant difference (Z = -6.9, p < 0.01). No significant complications were observed. Caregivers were highly satisfied in 90% of cases. Elastic adhesive dressing was observed as an effective and reliable technique, demonstrating a high rate of success without complications.
Dressings as an adjunct to pressure ulcer prevention: consensus panel recommendations.
Black, Joyce; Clark, Michael; Dealey, Carol; Brindle, Christopher T; Alves, Paulo; Santamaria, Nick; Call, Evan
2015-08-01
The formulation of recommendations on the use of wound dressings in pressure ulcer prevention was undertaken by a group of experts in pressure ulcer prevention and treatment from Australia, Portugal, UK and USA. After review of literature, they concluded that there is adequate evidence to recommend the use of five-layer silicone bordered dressings (Mepilex Border Sacrum(®) and 3 layer Mepilex Heel(®) dressings by Mölnlycke Health Care, Gothenburg, Sweden) for pressure ulcer prevention in the sacrum, buttocks and heels in high-risk patients, those in Emergency Department (ED), intensive care unit (ICU) and operating room (OR). Literature on which this recommendation is based includes one prospective randomised control trial, three cohort studies and two case series. Recommendations for dressing use in patients at high risk for pressure injury and shear injury were also provided. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Wiegand, C; Abel, M; Ruth, P; Hipler, U C
2011-11-01
A comprehensive in vitro approach was used to assess the effects of superabsorbent polymer (SAP) containing wound dressings in treatment of non-healing wounds. A slight negative effect on HaCaT cells was noted in vitro which is most likely due to the Ca(2+) deprivation of the medium by binding to the SAP. It could be shown that SAP wound dressings are able to bind considerable amounts of elastase reducing enzyme activity significantly. Furthermore, SAP's inhibit the formation of free radicals. The SAP-containing wound dressings tested also exhibited a significant to strong antimicrobial activity effectively impeding the growth of gram-negative and gram-positive bacteria as well as yeasts. In conclusion, in vitro data confirm the positive effect of SAP wound dressings observed in vivo and suggest that they should be specifically useful for wound cleansing.
Orbital State Manipulation of a Diamond Nitrogen-Vacancy Center Using a Mechanical Resonator
NASA Astrophysics Data System (ADS)
Chen, H. Y.; MacQuarrie, E. R.; Fuchs, G. D.
2018-04-01
We study the resonant optical transitions of a single nitrogen-vacancy (NV) center that is coherently dressed by a strong mechanical drive. Using a gigahertz-frequency diamond mechanical resonator that is strain coupled to a NV center's orbital states, we demonstrate coherent Raman sidebands out to the ninth order and orbital-phonon interactions that mix the two excited-state orbital branches. These interactions are spectroscopically revealed through a multiphonon Rabi splitting of the orbital branches which scales as a function of resonator driving amplitude and is successfully reproduced in a quantum model. Finally, we discuss the application of mechanical driving to engineering NV-center orbital states.
Surface-structured bacterial cellulose with guided assembly-based biolithography (GAB).
Bottan, Simone; Robotti, Francesco; Jayathissa, Prageeth; Hegglin, Alicia; Bahamonde, Nicolas; Heredia-Guerrero, José A; Bayer, Ilker S; Scarpellini, Alice; Merker, Hannes; Lindenblatt, Nicole; Poulikakos, Dimos; Ferrari, Aldo
2015-01-27
A powerful replica molding methodology to transfer on-demand functional topographies to the surface of bacterial cellulose nanofiber textures is presented. With this method, termed guided assembly-based biolithography (GAB), a surface-structured polydimethylsiloxane (PDMS) mold is introduced at the gas-liquid interface of an Acetobacter xylinum culture. Upon bacterial fermentation, the generated bacterial cellulose nanofibers are assembled in a three-dimensional network reproducing the geometric shape imposed by the mold. Additionally, GAB yields directional alignment of individual nanofibers and memory of the transferred geometrical features upon dehydration and rehydration of the substrates. Scanning electron and atomic force microscopy are used to establish the good fidelity of this facile and affordable method. Interaction of surface-structured bacterial cellulose substrates with human fibroblasts and keratinocytes illustrates the efficient control of cellular activities which are fundamental in skin wound healing and tissue regeneration. The deployment of surface-structured bacterial cellulose substrates in model animals as skin wound dressing or body implant further proves the high durability and low inflammatory response to the material over a period of 21 days, demonstrating beneficial effects of surface structure on skin regeneration.
Influence of phonon reservoir on photon blockade in a driven quantum dot-cavity system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Bo; Li, Gao-xiang, E-mail: gaox@phy.ccnu.edu.cn; Zhu, Jia-pei, E-mail: fengxue0506@163.com
2016-03-14
We theoretically investigate the influence of the phonon bath on photon blockade in a simultaneously driven dot-cavity system. An optimal condition for avoiding two-photon excitation of a cavity field is put forward which can be achieved by modulating the phase difference and the strengths of the driving fields. The second-order correlation function and the mean photon number of the cavity field are discussed. In the absence of phonon effect, the strong photon blockade in a moderate quantum dot (QD)-cavity coupling regime occurs, which can be attributed to the destructive quantum interference arisen from different transition paths induced by simultaneously drivingmore » the dressed QD-cavity system. The participation of acoustic-phonon reservoir produces new transition channels for the QD-cavity system, which leads to the damage of destructive interference. As a result, the photon blockade effect is hindered when taking the electron-phonon interaction into account. It is also found that the temperature of the phonon reservoir is disadvantageous for the generation of photon blockade.« less
Dress Fashion in Feminist and Child Rights Campaigns in Ghanaian Public Sculptures of the 1990s
ERIC Educational Resources Information Center
Essel, Osuanyi Quaicoo; Opoku-Mensah, Isaac
2017-01-01
This article examines how dress fashion in outdoor sculptures of the 1990s in the Accra cityscape accentuated feminist activism, sensitised child right campaigns, and encouraged girl-child education in support of governmental efforts and activism of civil society organisations in Ghana. It gives attention to how dress fashion of the time was used…
USDA-ARS?s Scientific Manuscript database
An intelligent dressing is a self-adjusting material with multifunctional properties and/or a biosensor-interface designed to treat specific pathological issues of wounds at a molecular or cellular level. The ability to detect and treat excessive protease levels in wounds, one indicator of chronic w...
ERIC Educational Resources Information Center
Sebastian, Richard J.; Bristow, Dennis
2008-01-01
In this article, the authors examine the effects of style of dress, forms of address, and gender of the stimulus person on business students' perceptions of professors' attributes. Student participants (125 women, 132 men) rated the stimulus person on indexes of attractiveness, trustworthiness, credibility, and likeability. Style of dress and form…
Politicas de uniformes y codigos de vestuario (Uniforms and Dress-Code Policies). ERIC Digest.
ERIC Educational Resources Information Center
Lumsden, Linda
This digest in Spanish examines schools' dress-code policies and discusses the legal considerations and research findings about the effects of such changes. Most revisions to dress codes involve the use of uniforms, typically as a way to curb school violence and create a positive learning environment. A recent survey of secondary school principals…
Evidence review: the clinical benefits of Safetac technology in wound care.
Davies, Phil; Rippon, Mark
2008-11-01
Common causes of trauma and wound pain include: the removal of dressings that become stuck to the wound bed; skin stripping of peri-wound skin, as a result of the repeated application and removal of adhesive dressings; and tissue excoriation and maceration of the peri-wound skin, due to inadequate management of wound exudate. This supplement outlines how dressings with Safetac adhesive technology can help clinicians to avoid these problems. A review of the clinical and scientific evidence relating to dressings with Safetac clearly demonstrates that they can be used to prevent trauma and minimise pain on a wide range of wound types and skin injuries.
The Concept of Fashion Design on the Basis of Color Coordination Using White LED Lighting
NASA Astrophysics Data System (ADS)
Mizutani, Yumiko; Taguchi, Tsunemasa
This thesis focuses on the development of fashion design, especially a dress coordinated with White LED Lighting (=LED). As for the design concept a fusion of the advanced science and local culture was aimed for. For such a reason this development is a very experimental one. Here in particular I handled an Imperial Court dinner dress for the last Japanese First Lady, Mrs. Akie Abe who wore it at the Imperial Court dinner for the Indonesian First Couple held on November 2006 to. This dress made by Prof. T. Taguchi and I open up a new field in the dress design.
Dutra, R A A; Salomé, G M; Leal, L M F; Alves, M G; Moura, J P; Silva, A T; Pereira, V O S; de Brito, M J A; Ferreira, L M
2016-11-02
To evaluate and compare the costs of using a transparent polyurethane film (PF) and hydrocolloid dressing (HD) in the prevention of pressure ulcers (PUs). This descriptive, observational, longitudinal, comparative study was conducted in the intensive care units, coronary care unit and medical clinic of a charity hospital in Brazil. Data were collected during a 30-day study period, consisting of physical examination, assessment of risk factors for PU development and application of the Braden scale, which were performed at inclusion in the study and once daily during hospitalisation. Either PF or HD was applied bilaterally in the sacral and trochanteric regions for prevention of PUs in patients at a moderate to high risk of PUs according to the Braden scale, and costs of using PU preventive dressings were estimated. The mean total costs per dressing change per patient when using the HD and PF to prevent PUs were 413.60 BRL and 74.04 BRL, respectively. There were significant between-group differences in mean costs for all variables, except for saline solution and nurse-technician services. Results showed that the mean cost per dressing change per patient was lower when using the transparent PF than when using the HD.
The Dress: Transforming a web viral event into a scientific survey.
Moccia, Marcello; Lavorgna, Luigi; Lanzillo, Roberta; Brescia Morra, Vincenzo; Tedeschi, Gioacchino; Bonavita, Simona
2016-05-01
The Dress picture recently has become a hot topic on the Internet, prompting a debate whether it was black and blue, or white and gold. To investigate The Dress color perception in both multiple sclerosis (MS) patients, characterized by frequent visual system impairment with ensuing color vision effects, and general population. We developed a questionnaire to record demographics, clinical features, and The Dress color perception, posted on general and MS-specific social networks. No statistically significant differences were observed in The Dress color perception between MS patients (n=103) and general population (n=441). Furthermore, white and gold color perception was positively associated with aging in the general population (p=0.04), whereas negatively associated with progressive course (p=0.03) and longer disease duration (p<0.001) in MS patients, independently from patients' age. The Dress black and blue or white and gold perception might be due to aging in the general population, whereas black and blue perception, despite of aging, might suggest a specific effect of the MS burden (i.e. disease duration and progression) on the visual structures specifically involved in the white and gold perception. Copyright © 2016 Elsevier B.V. All rights reserved.
Endo, Arisa; Suzuki, Makoto; Akagi, Atsumi; Chiba, Naoyuki; Ishizaka, Ikuyo; Matsunaga, Atsuhiko; Fukuda, Michinari
2015-03-01
The purpose of this study was to examine the reliability and validity of the Upper-body Dressing Scale (UBDS) for buttoned shirt dressing, which evaluates the learning process of new component actions of upper-body dressing in patients diagnosed with dementia and hemiparesis. This was a preliminary correlational study of concurrent validity and reliability in which 10 vascular dementia patients with hemiparesis were enrolled and assessed repeatedly by six occupational therapists by means of the UBDS and the dressing item of the Functional Independence Measure (FIM). Intraclass correlation coefficient was 0.97 for intra-rater reliability and 0.99 for inter-rater reliability. The level of correlation between UBDS score and FIM dressing item scores was -0.93. UBDS scores for paralytic hand passed into the sleeve and sleeve pulled up beyond the shoulder joint were worse than the scores for the other components of the task. The UBDS has good reliability and validity for vascular dementia patients with hemiparesis. Further research is needed to investigate the relation between UBDS score and the effect of intervention and to clarify sensitivity or responsiveness of the scale to clinical change. Copyright © 2014 John Wiley & Sons, Ltd.
Many-body interactions in quasi-freestanding graphene
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siegel, David; Park, Cheol-Hwan; Hwang, Choongyu
2011-06-03
The Landau-Fermi liquid picture for quasiparticles assumes that charge carriers are dressed by many-body interactions, forming one of the fundamental theories of solids. Whether this picture still holds for a semimetal such as graphene at the neutrality point, i.e., when the chemical potential coincides with the Dirac point energy, is one of the long-standing puzzles in this field. Here we present such a study in quasi-freestanding graphene by using high-resolution angle-resolved photoemission spectroscopy. We see the electron-electron and electron-phonon interactions go through substantial changes when the semimetallic regime is approached, including renormalizations due to strong electron-electron interactions with similarities tomore » marginal Fermi liquid behavior. These findings set a new benchmark in our understanding of many-body physics in graphene and a variety of novel materials with Dirac fermions.« less
Cavity-photon contribution to the effective interaction of electrons in parallel quantum dots
NASA Astrophysics Data System (ADS)
Gudmundsson, Vidar; Sitek, Anna; Abdullah, Nzar Rauf; Tang, Chi-Shung; Manolescu, Andrei
2016-05-01
A single cavity photon mode is expected to modify the Coulomb interaction of an electron system in the cavity. Here we investigate this phenomena in a parallel double quantum dot system. We explore properties of the closed system and the system after it has been opened up for electron transport. We show how results for both cases support the idea that the effective electron-electron interaction becomes more repulsive in the presence of a cavity photon field. This can be understood in terms of the cavity photons dressing the polarization terms in the effective mutual electron interaction leading to nontrivial delocalization or polarization of the charge in the double parallel dot potential. In addition, we find that the effective repulsion of the electrons can be reduced by quadrupolar collective oscillations excited by an external classical dipole electric field.
Mori, Michela; Rossi, Silvia; Ferrari, Franca; Bonferoni, Maria C; Sandri, Giuseppina; Riva, Federica; Tenci, Marika; Del Fante, Claudia; Nicoletti, Giovanni; Caramella, Carla
2016-03-01
Platelet lysate (PL) was loaded into dressings based on chitosan glutamate (CSG) low and high molecular weight, sericin (Ser), and glycine (Gly). A synergic effect of Ser and PL on fibroblast proliferation was proved in vitro. Two different PL loading approaches were considered: the first provided to prepare dressings by freeze-drying a mixture of PL and CSG/Gly/Ser solution, the second approach consisted in the extemporarily loading of PL in the CSG/Gly/Ser freeze-dried dressings. As for the first approach, PL loading did not produce any variation in dressing mechanical properties. Such dressings absorbed a high amount (about 8-fold of dry weight) of phosphate-buffered saline (fluid mimicking wound exudate), forming a gel with pseudoplastic and elastic properties. Platelet-derived growth factor AB assay indicated that neither freeze-drying nor the excipients alter PL growth factor content. As for the second approach, mechanical and rheological properties of the gel formed upon PL absorption enabled to choose a PL loading of about 90 μL/cm(2). Upon contact with fibroblasts, all PL loaded formulations increased the number not only of viable cells but also of those in the proliferative phase. Histological studies effected on human skin strips pointed out the positive effect of PL loaded dressings on dermal matrix reconstruction. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Ferreira, Lydia M; Blanes, Leila; Gragnani, Alfredo; Veiga, Daniela F; Veiga, Frederico; Nery, Gilka B; Rocha, Gustavo H; Gomes, Heitor C; Rocha, Mario G; Okamoto, Regina
2009-06-01
Objective. The aim of this study was to compare the health-related quality of life (HRQoL) and self-esteem of patients who underwent split-thickness skin grafting, when either cellulose dressings or rayon dressings were applied to the donor sites. A total of 25 patients, who were enrolled at five participant hospitals and required split-thickness skin grafting for various clinical reasons, were randomized into two treatment groups, the rayon dressing group (n = 13), or the cellulose dressing group (n = 12). All patients were assessed preoperatively and 60 days postoperatively. The HRQoL was assessed with the Short Form-36 (SF-36) health survey questionnaire, and self-esteem was evaluated using the Rosenberg Self-Esteem Scale (RSE)/UNIFESP-EPM (Brazilian versions). There were no surgery-related complications during the study period. In both treatment groups, SF-36 scores for emotional role, mental health, vitality, and general health decreased from baseline. RSE scores increased from baseline in both treatment groups, showing a reduction in self-esteem after treatment. There was a statistical difference (P = 0.024) in the SF-36 bodily pain domain for the rayon group. There were no significant differences in HRQoL and self-esteem between treatment groups. In the rayon-dressing group, there was a significant decrease in bodily pain from baseline .
A review of negative-pressure wound therapy in the management of burn wounds.
Kantak, Neelesh A; Mistry, Riyam; Halvorson, Eric G
2016-12-01
Negative pressure has been employed in various aspects of burn care and the aim of this study was to evaluate the evidence for each of those uses. The PubMed and Cochrane CENTRAL databases were queried for articles in the following areas: negative pressure as a dressing for acute burns, intermediate treatment prior to skin grafting, bolster for skin autografts, dressing for integration of dermal substitutes, dressing for skin graft donor sites, and integrated dressing in large burns. Fifteen studies met our inclusion criteria. One study showed negative pressure wound therapy improved perfusion in acute partial-thickness burns, 8 out of 9 studies showed benefits when used as a skin graft bolster dressing, 1 out of 2 studies showed improved rate of revascularization when used over dermal substitutes, and 1 study showed increased rate of re-epithelialization when used over skin graft donor sites. Negative pressure can improve autograft take when used as a bolster dressing. There is limited data to suggest that it may also improve the rate of revascularization of dermal substitutes and promote re-epithelialization of skin graft donor sites. Other uses suggested by studies that did not meet our inclusion criteria include improving vascularity in acute partial-thickness burns and as an integrated dressing for the management of large burns. Further studies are warranted for most clinical applications to establish negative pressure as an effective adjunct in burn wound care. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Tran, Phat L; Hamood, Abdul N; de Souza, Anselm; Schultz, Gregory; Liesenfeld, Bernd; Mehta, Dilip; Reid, Ted W
2015-01-01
Bacterial infection of acute and chronic wounds impedes wound healing significantly. Part of this impediment is the ability of bacterial pathogens to grow in wound dressings. In this study, we examined the effectiveness of a polyurethane (PU) foam wound dressings coated with poly diallyl-dimethylammonium chloride (pDADMAC-PU) to inhibit the growth and biofilm development by three main wound pathogens, Staphylococcus aureus, Pseudomonas aeruginosa, and Acinetobacter baumannii, within the wound dressing. pDADMAC-PU inhibited the growth of all three pathogens. Time-kill curves were conducted both with and without serum to determine the killing kinetic of pDADMAC-PU. pDADMAC-PU killed S. aureus, A. baumannii, and P. aeruginosa. The effect of pDADMAC-PU on biofilm development was analyzed quantitatively and qualitatively. Quantitative analysis, colony-forming unit assay, revealed that pDADMAC-PU dressing produced more than eight log reduction in biofilm formation by each pathogen. Visualization of the biofilms by either confocal laser scanning microscopy or scanning electron microscopy confirmed these findings. In addition, it was found that the pDADMAC-PU-treated foam totally inhibited migration of bacteria through the foam for all three bacterial strains. These results suggest that pDADMAC-PU is an effective wound dressing that inhibits the growth of wound pathogens both within the wound and in the wound dressing. © 2014 by the Wound Healing Society.
TRANSPORT EQUATION OF A PLASMA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balescu, R.
1960-10-01
It is shown that the many-body problem in plasmas can be handled explicitly. An equation describing the collective effects of the problem is derived. For simplicity, a onecomponent gas is considered in a continuous neutralizing background. The tool for handling the problem is provided by the general theory of irreversible processes in gases. The equation derived describes the interaction of electrons which are"dressed" by a polarization cloud. The polarization cloud differs from the Debye cloud. (B.O.G.)
The Action of a Magnetic Field on Water,
The effect of a low intensity magnetic field on water as a flotation medium with the enrichment of coal and dressing of copper sulfied ore is studied...magnetic field with flotation is expressed. The imposition of an external magnetic field disturbs the energy state of water, which leads to a change in...intermolecular interaction, stability of hydrogen bonds, deterioration in the wettability of rigid surfaces, and a change in the technological indices of flotation enrichment. (Author)
9. Photographic copy of blueprint dated 1931; H.P. Henschien, Chicago, ...
9. Photographic copy of blueprint dated 1931; H.P. Henschien, Chicago, architect; Original in collection of Rath drawings and blueprints owned by Waterloo Community Development Board, Waterloom, Iowa; PLAN OF HOG DRESSING FLOOR ON 4TH LEVEL OF BUILDING 92; SHOWS LAYOUT OF DRESSING EQUIPMENT - Rath Packing Company, Hog Dressing Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
Vas, Jorge; Modesto, Manuela; Mendez, Camila; Perea-Milla, Emilio; Aguilar, Inmaculada; Carrasco-Lozano, Jesus Manuel; Faus, Vicente; Martos, Francisco
2008-01-01
Background Venous leg ulcers constitute a chronic recurring complaint that affects 1.0–1.3% of the adult population at some time in life, and which corresponds to approximately 75% of all chronic ulcers of the leg. Multilayer compression bandaging is, at present, the only treatment that has been proved to be effective in treating this type of ulcer. There is no consensus, however, about the dressings that may be applied, beneath the compression, to promote the healing of this type of ulcer, as there does not seem to be any added benefit from using special dressings rather than simple, low-adherence ones. As well as analgesia, acupuncture provokes peripheral vasodilation, in skin and muscles – which has been demonstrated both experimentally and in clinical practice – probably due to the axon reflex, among other mechanisms. The aim of the present study is to measure the effectiveness and cost of compression treatment for venous leg ulcers combined with special dressings, in comparison with low-adherence ones and acupuncture. Methods/design Cluster-randomized open-labeled trial, at 15 primary healthcare clinics in the Sevilla-Sur Healthcare District, with a control group treated with compression bandaging and low-adherence dressings; the experiment will consist, on the one hand, of the compression treatment applied in combination with special dressings (Treatment 1), and on the other, the compression treatment applied in association with low-adherence dressings, together with acupuncture (Treatment 2). Discussion The results will be measured and recorded in terms of the median time elapsed until complete healing of the ulcer, and the rate of complete healing at 3 months after beginning the treatment. An economic analysis will also be made. This study, carried out in the context of real clinical practice, will provide information for decision-taking concerning the effectiveness of special dressings. Moreover, for the first time a high-quality study will evaluate the effectiveness of acupuncture in the process of healing venous leg ulcers. Trial registration Current Controlled Trials ISRCTN26438275. PMID:18547419
Coufal, C D; Chavez, C; Niemeyer, P R; Carey, J B
2006-03-01
Top-dressing is a method of broiler litter management in which a thin layer of new, clean litter material is spread over the top of previously used litter prior to placement of a new flock. This fresh layer of bedding material increases the absorptive capacity of the litter and decreases litter caking. Although this practice has been widely used in the poultry industry for many years, no research has been conducted to quantify the effects the practice has on broiler performance, litter production rates, and nutrient content, or the ability of broiler litter to retain manure N and prevent volatilization. An experiment was conducted to quantify these parameters under simulated commercial conditions in a research facility. Nine consecutive flocks of broilers were reared on recycled broiler litter that had previously been used for 9 flocks. Control pens received no litter treatment whereas top-dressed pens received a thin layer of new rice hulls (1 to 2 cm) before the placement of each flock. Nitrogen loss was calculated using the mass balance method. Average broiler performance was not different between the top-dressed and control pens. Top-dressing of litter significantly (P < 0.05) reduced caked litter production compared with control pens in 6 of 9 flocks. However, average total litter production over all 9 flocks was not different between the 2 litter management strategies. In all flocks, litter N content was significantly reduced in top-dressed pens compared with control pens. As a result, litter C:N ratios were significantly higher for pens with top-dressed litter. Differences in N loss between the treatments were not consistent. Average N loss for all flocks was 10.61 and 11.92 g of N/kg of marketed broiler for control and top-dressed pens, respectively, or 20.1 and 22.5% of N inputs, respectively. Based on this experiment, top-dressing of recycled broiler litter would not be recommended as a strategy to reduce the volatilization of N from broiler rearing facilities and, in fact, may actually increase N loss.
Song, David H; Wu, Liza C; Lohman, Robert F; Gottlieb, Lawrence J; Franczyk, Mieczyslawa
2003-01-01
A method to refine the treatment of sternal wounds using Vacuum Assisted Closure (V.A.C.) therapy as the bridge between débridement and delayed definitive closure is described. A retrospective review of 35 consecutive patients with sternal wound complications over a 2-year period (March of 1999 to March of 2001) was performed. The treatment of sternal wounds with traditional twice-a-day dressing changes was compared with the treatment with the wound V.A.C. device. An analysis of the number of days between initial débridement and closure, number of dressing changes, number and types of flaps needed for reconstruction, and complications was performed. Eighteen patients were treated with traditional twice-a-day dressing changes and 17 patients were treated with V.A.C. therapy alone. The two groups were similar regarding age, sex, type of cardiac procedure, and type of sternal wound. The V.A.C. therapy group had a trend toward a shorter interval between débridement and closure, with a mean of 6.2 days, whereas the dressing change group had mean of 8.5 days. The V.A.C. therapy group had a significantly lower number of dressing changes, with a mean of three, whereas the twice-a-day dressing change group had a mean of 17 (p < 0.05). Reconstruction required an average of 1.5 soft-tissue flaps per patient treated with traditional dressing changes versus 0.9 soft-tissue flaps per patient for those treated with V.A.C. therapy (p < 0.05). Before closure, there was one death among patients undergoing dressing changes and three in the V.A.C. therapy group, all of which were unrelated to the management of the sternal wound. Patients with sternal wounds who have benefited from V.A.C. therapy alone have a significant decrease in the number of dressing changes and number of soft-tissue flaps needed for closure. Finally, the V.A.C. therapy group had a trend toward a decreased number of days between débridement and closure.
Souliotis, Kyriakos; Kalemikerakis, Ioannis; Saridi, Maria; Papageorgiou, Manto; Kalokerinou, Athena
2016-05-01
The aim of the study was a cost and clinical effectiveness analysis between moist wound healing dressings and gauze in a homecare set up for the treatment of stage III and IV pressure ulcers up to complete healing. In addition, we assessed the overall economic burden on the Healthcare System. Treatment method for each patient was chosen randomly by using sealed opaque envelopes. The authors monitored the healing progress and recorded treatment costs without interfering with the treatment process. The healing progress was estimated by using surface measurement transparent films. To estimate treatment costs, the authors took into account labor costs, cost of dressings, as well the cost of other materials such as cleansing gauzes, normal saline, syringes, examination gloves, antiseptics and adhesive tape. The patient group under treatment with moist wound healing dressings consisted of 27 men and 20 women aged 75.1 ± 8,6 and had an average ulcer surface of 43.5 ± 30.70 cm(2) ; the patient group under treatment with gauze comprised 25 men and 23 women aged 77.02 ± 8.02 and had an average ulcer surface 41.52 ± 29.41 cm(2) (p = 0.25, 95% CI, Student's t test). The average healing time for the moist wound healing dressings group' was 85.56 ± 52.09 days, while 121.4 ± 52.21 days for the "gauze group" (p = 0.0001, 95% CI, Student's t test). The dressing change frequency per patient was reduced in the "moist wound healing dressings group," 49.5 ± 29.61, compared with a dressing change frequency per patient of 222.6 ± 101.86 for the "gauze group" (p = 0.0001, 95% CI, Student's t test). The use of moist wound healing dressings had a lower total treatment cost of 1,351 € per patient compared with, the use of gauzes (3,888 €). © 2016 by the Wound Healing Society.
Chiral phases of fundamental and adjoint quarks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Natale, A. A.; Instituto de Física Teórica - UNESP Rua Dr. Bento T. Ferraz, 271, Bl.II - 01140-070, São Paulo, SP
2016-01-22
We consider a QCD chiral symmetry breaking model where the gap equation contains an effective confining propagator and a dressed gluon propagator with a dynamically generated mass. This model is able to explain the ratios between the chiral transition and deconfinement temperatures in the case of fundamental and adjoint quarks. It also predicts the recovery of the chiral symmetry for a large number of quarks (n{sub f} ≈ 11 – 13) in agreement with lattice data.
Ozisik, Lale; Tanriover, Mine Durusu; Saka, Esen
2016-01-01
Drug rash with eosinophilia and systemic symptoms (DRESS) is a severe drug hypersensitivity reaction characterized by rash, fever and multi-organ failure. Limbic encephalitis (LE) is a rare disorder characterized by cognitive dysfunction with memory disturbance, seizures and psychiatric symptoms. We herein present an unusual case of DRESS syndrome due to lamotrigine with reactivation of Epstein-Barr virus, which developed autoimmune LE and syndrome of inappropriate antidiuretic hormone secretion. Discontinuation of lamotrigine, administration of methylprednisolone and intravenous immunoglobulin led to improvement. The LE in this case might have been caused by an autoimmune inflammatory mechanism associated with DRESS syndrome.
Honey-based dressings and wound care: an option for care in the United States.
Pieper, Barbara
2009-01-01
Honey-based wound dressings have been used worldwide since ancient times. A honey product received US Federal Drug Administration approval in 2007, making this dressing an option for wound care. Honey has been found to exert anti-inflammatory and antibacterial effects without antibiotic resistance, promote moist wound healing, and facilitate debridement. However, it may cause a stinging pain. As is true of any wound dressing, its use must be carefully selected and monitored. Continued research is needed to add to its evidence base. This article provides a summary of the current evidence base for the use of honey and a review of its therapeutic effects and discusses implications for WOC nursing practice.
Honey as a dressing for chronic wounds in adults.
Fox, Carolyn
2002-10-01
The aim of this review was to identify whether in adults with chronic wounds the use of honey as a wound dressing improves wound management outcomes. As no randomized controlled trials or comparative studies comparing the use of honey as a chronic wound dressing with usual treatment could be found, the review is based on case studies and serial case studies. These were reviewed using a framework broadly based on wound care case study guidelines (Nelson, 2000) and cohort study guidelines (Greenhalgh and Donald, 2000). Based on the case studies reviewed, honey appears to be a useful dressing in adults with chronic wounds, but the available evidence is weak and therefore must be interpreted with caution.
Choi, Jong Seo; Kim, Dong Wuk; Kim, Dong Shik; Kim, Jong Oh; Yong, Chul Soon; Cho, Kwan Hyung; Youn, Yu Seok; Jin, Sung Giu; Choi, Han-Gon
2016-10-01
To develop a novel neomycin sulfate-loaded hydrogel dressing (HD), numerous neomycin sulfate-loaded HDs were prepared with various amounts of polyvinyl alcohol (PVA), polyvinyl pyrrolidone (PVP) and sodium alginate (SA) using freeze-thawing technique, and their physical dressing properties, drug release, in vivo wound curing and histopathology in diabetic-induced rats were assessed. SA had a positive effect on a swelling capacity, but a negative effect on the physical dressing properties and drug release of HD. However, PVP did the opposite. In particular, the neomycin sulfate-loaded HD composed of drug, PVA, PVP and SA at the weight ratio of 1/10/0.8/0.8 had excellent swelling and bioadhesive capacity, good elasticity and fast drug release. Moreover, this HD gave more improved wound curing effect compared to the commercial product, ensured the disappearance of granulation tissue and recovered the wound tissue to normal. Therefore, this novel neomycin sulfate-loaded HD could be an effective pharmaceutical product for the treatment of wounds.
Chia, E K; Jih, C S
1994-09-01
We examined the effects of stereotyping on impression formation when encountering people dressed to represent a religious faith. We used stimulus photographs of eight male and female models dressed casually and a second photograph of one male and one female model in religious attire that was placed beside the control photos of models dressed causally. From each set of photographs, subjects selected a photo of the person with whom they would associate the various positive personality traits suggested by our stimulus questions. Subjects were students from a U.S. Catholic school, a U.S. public school, and a Malaysian Muslim school. All the subjects attributed more of the positive traits to photos of the models who were religiously attired than to photos of those who were casually dressed, but subjects from U.S. schools attributed more of the positive traits to the photos of religiously dressed models than did the subjects from the Malaysian school.
Kohl, K S; Farley, T A
2000-12-01
An outbreak of salmonellosis occurred among 63 wedding participants. The outbreak was investigated through cohort, laboratory, and environmental studies. Consumption of rice-dressing made from a commercially cooked, meat-based, rice-dressing mix was strongly associated with illness. Nineteen patient isolates, six company/grocery store isolates cultured from the rice-dressing mix, and one environmental isolate from a pump in the production line were of an identical outbreak strain of Salmonella Infantis characterized by pulsed-field gel electrophoresis. In the production line, cooked rice-dressing mix tested negative for S. Infantis before and positive after contact with the contaminated pump. The dressing-mix had an estimated 200 colony-forming units of salmonella per gram of product, and > 180,000 pounds were distributed in 9 states for > or = 2 months before contamination was recognized. Food manufacturers should be required to use systematic, hazard analysis critical control point risk management practices for all processed meat products, validated by periodic microbiologic monitoring of the end product.
Hwang, Deng-Fwu; Hsieh, Yu-Wen; Shiu, Yu-Cheng; Chen, Shu-Kong; Cheng, Chao-An
2002-02-01
There were five victims of neurotoxic food poisoning from a dried dressed fish fillet in Changhua County, Taiwan, in February 2000. The toxicity of the dried dressed fish fillets was 243 mouse units per g according to a tetrodotoxin bioassay. The partially purified toxin was identified as tetrodotoxin and anhydrotetrodotoxin. The sequence of the 376-nucleotide region in the cytochrome b gene of the mitochondrial DNA exhibited the same genotype as that of the toxic puffer fish Lagocephalus lunaris. The same single restriction site for Hinfl was found in the polymerase chain reaction (PCR) products from the dried dressed fish fillet and the muscle of L. lunaris, yielding two DNA fragments of 170 and 206 bp. However, no restriction site for Hinfl was found in the PCR products from other toxic puffer fishes, including Takifugu niphobles, Takifugu oblongus, and Takifugu rubripes. Therefore, the species of the dried dressed fish fillet was identified as L. lunaris and its causative agent was identified as tetrodotoxin.
Diluted povidone-iodine versus saline for dressing metal-skin interfaces in external fixation.
Chan, C K; Saw, A; Kwan, M K; Karina, R
2009-04-01
To compare infection rates associated with 2 dressing solutions for metal-skin interfaces. 60 patients who underwent distraction osteogenesis with external fixators were equally randomised into 2 dressing solution groups (diluted povidone-iodine vs. saline). Fixations were attained using either rigid stainless steel 5-mm diameter half pins or smooth stainless steel 1.8-mm diameter wires. Half-pin fixation had one metal-skin interface, whereas wire fixation had 2 interfaces. Patients were followed up every 2 weeks for 6 months. Of all 788 metal-skin interfaces, 143 (18%) were infected: 72 (19%) of 371 in the diluted povidone-iodine group and 71 (17%) of 417 in the saline group. Dressing solution and patient age did not significantly affect infection rates. Half-pin fixation was more likely to become infected than wire fixation (25% vs 15%). Saline is as effective as diluted povidone-iodine as a dressing solution for metal-skin interfaces of external fixators. Saline is recommended in view of its easy availability and lower costs.
Richards, Alastair J; Hagelstein, Sue M; Patel, Girish K; Ivins, Nicola M; Sweetland, Helen M; Harding, Keith G
2011-12-01
Combining silver-based dressings with negative pressure therapy after radical excision of chronically infected breast disease is a novel application of two technologies. One patient with complex, chronic, infected breast disease underwent radical excision of the affected area and was treated early with a combination of silver-based dressings and topical negative pressure therapy. The wound was then assessed sequentially using clinical measurements of wound area and depth, pain severity scores and level of exudation. It is possible to combine accepted techniques with modern dressing technologies that result in a positive outcome. In this case, the combination of a silver-based dressing with negative pressure therapy following radical excision proved safe and was well tolerated by the patient. Full epithelisation of the wound was achieved and there was no recurrence of the infection for the duration of the treatment. © 2011 The Authors. © 2011 Blackwell Publishing Ltd and Medicalhelplines.com Inc.
Electron-hydrogen collisions in a laser field. (Reannouncement with new availability information)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, P.H.; Flannery, M.R.
1991-12-31
The Floquet treatment has already been successfully employed (Chu, Potvliege and Shakeshaft) in calculations of laser-induced multiphoton ionizations, where it provides dressed states for an atom in a laser field. The (perturbative) dressing of target states can have important consequences in laser-assisted scattering was illustrated by Byron and Joachain. These dressed states are useful, not only for laser-induced phenomena, but also as a collisional basis set for laser-assisted collisions. In this role they are in fact very appealing, since the Floquet treatment naturally lends itself to a time-independent analysis, and hence are compatible with present field-free scattering theories. Despite themore » apparent applicability of this approach, work along these lines has only just recently appeared (Sharma and Mohan, Smith and Flannery, Burke et al). Byron and Joachain have illustrated that perturbative dressing of the target states can have important consequences in laser-assisted scattering. Floquet dressing however provides a more complete description (Smith and Flannery).« less
Wettstein, Felix E; Kasteel, Roy; Garcia Delgado, Maria F; Hanke, Irene; Huntscha, Sebastian; Balmer, Marianne E; Poiger, Thomas; Bucheli, Thomas D
2016-08-24
Pesticide transport from seed dressings toward subsurface tile drains is still poorly understood. We monitored the neonicotinoid insecticides imidacloprid and thiamethoxam from sugar beet seed dressings in flow-proportional drainage water samples, together with spray applications of bromide and the herbicide S-metolachlor in spring and the fungicides epoxiconazole and kresoxim-methyl in summer. Event-driven, high first concentration maxima up to 2830 and 1290 ng/L for thiamethoxam and imidacloprid, respectively, were followed by an extended period of tailing and suggested preferential flow. Nevertheless, mass recoveries declined in agreement with the degradation and sorption properties collated in the groundwater ubiquity score, following the order bromide (4.9%), thiamethoxam (1.2%), imidacloprid (0.48%), kresoxim-methyl acid (0.17%), S-metolachlor (0.032%), epoxiconazole (0.013%), and kresoxim-methyl (0.003%), and indicated increased leaching from seed dressings compared to spray applications. Measured concentrations and mass recoveries indicate that subsurface tile drains contribute to surface water contamination with neonicotinoids from seed dressings.
Systematic review of the use of prophylactic dressings in the prevention of pressure ulcers.
Clark, Michael; Black, Joyce; Alves, Paulo; Brindle, Ct; Call, Evan; Dealey, Carol; Santamaria, Nick
2014-10-01
This systematic review considers the evidence supporting the use of prophylactic dressings for the prevention of pressure ulcer. Electronic database searches were conducted on 25 July 2013. The searches found 3026 titles and after removal of duplicate records 2819 titles were scanned against the inclusion and exclusion criteria. Of these, 2777 were excluded based on their title and abstract primarily because they discussed pressure ulcer healing, the prevention and treatment of other chronic and acute wounds or where the intervention was not a prophylactic dressing (e.g. underpads, heel protectors and cushions). Finally, the full text of 42 papers were retrieved. When these 42 papers were reviewed, 21 were excluded and 21 were included in the review. The single high-quality randomised controlled trial (RCT) and the growing number of cohort, weak RCT and case series all suggest that the introduction of a dressing as part of pressure ulcer prevention may help reduce pressure ulcer incidence associated with medical devices especially in immobile intensive care unit patients. There is no firm clinical evidence at this time to suggest that one dressing type is more effective than other dressings. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Chronic Hepatitis C Therapy in Liver Cirrhosis Complicated by Telaprevir-Induced DRESS.
Mousa, Omar Y S; Khalaf, Rossa; Shannon, Rhonda L; Egwim, Chukwuma I; Zela, Scott A; Ankoma-Sey, Victor
2014-01-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a rare yet severe adverse drug-induced reaction with up to 10% mortality rate. Recent clinical trials reported an association between DRESS and telaprevir (TVR), an NS3/4A protease inhibitor of chronic hepatitis C (CHC) virus genotype 1. Its diagnosis is challenging given the variable pattern of cutaneous eruption and the myriad internal organ involvement. We present two patients who are middle-aged, obese, and white with CHC cirrhosis. They both developed a progressive diffuse, painful pruritic maculopapular rash at weeks 8 and 10 of CHC therapy with TVR, Peg-Interferon alfa-2a, and Ribavirin. They had no exposures to other medications that can cause this syndrome. Physical exam and labs and skin biopsy supported a "Definite" clinical diagnosis of DRESS, per RegiSCAR criteria. Thus Telaprevir-based triple therapy was discontinued and both patients experienced rapid resolution of the systemic symptoms with gradual improvement of eosinophilia and the skin eruption. These two cases illustrate the paramount importance of having a high index of suspicion for TVR-induced DRESS, critical for early diagnosis. Immediate discontinuation of TVR is essential in prevention of a potentially life-threatening complication. Risk factors for development of DRESS in patients receiving TVR remain to be elucidated.
Hermans, Michel H E; Kwon Lee, S; Ragan, Mitzie R; Laudi, Pam
2015-03-01
This retrospective observational study analyzed lesions with regard to healing trends and cost of materials. The observed lesions were mostly postsurgical or stage IV pressure ulcers in patients with serious morbidity. The wounds were treated with a hydrokinetic fiber dressing (sorbion Sachet S, sorbion Gmbh & Co, a BSN medical company, Senden, Germany) (n = 26) or negative pressure wound therapy (NPWT) (n = 16). Primary healing trends (ie, reduction of wound size, change from necrosis to granulation tissue, and change from granulation tissue to epithelium) and secondary healing trends (ie, periwound conditions) were similar for wounds treated with the hydrokinetic dressing when compared to wounds treated with NPWT. Cost of materials was substantially lower for wounds treated with the hydrokinetic fiber dressing compared to the NPWT, with cost reductions of $1,640 (348%) to $2,242 (1794%) per wound, depending on the criteria used for the analysis. In this set of wounds, the hydrokinetic fiber dressing was shown to lead to similar healing results while providing substantial reductions of the cost of materials. For the types of wounds presented in this observational study, the hydrokinetic fiber dressing seems to be an effective substitution for negative pressure wound therapy.
Lavery, Lawrence A; La Fontaine, Javier; Thakral, Gaurav; Kim, Paul J; Bhavan, Kavita; Davis, Kathryn E
2014-03-01
This study was designed to compare two approaches to negative-pressure wound therapy: 125-mmHg pressure with a polyurethane foam dressing and 75-mmHg pressure with a silicone-coated dressing. Forty patients with diabetic foot wounds, after incision and drainage or amputation for infection, were assigned randomly to negative-pressure wound therapy with 75-mmHg continuous pressure with a silicone-covered dressing (75-mmHg group) or 125-mmHg with a polyurethane foam dressing (125-mmHg group) for up to 4 weeks or until surgical closure. There was no difference in the proportion of wounds that were closed surgically (75-mmHg group, 50 percent; 125-mmHg group, 60 percent), wounds that demonstrated 50 percent wound area reduction (75-mmHg group, 65 percent; 125-mmHg group, 80 percent), or wounds that demonstrated 50 percent wound volume reduction after 4 weeks of therapy (75-mmHg group, 95 percent; 125-mmHg group, 90 percent). The authors' results suggest that there was no difference in outcomes in wounds treated with low pressure (75 mmHg) with a silicone-coated interface and high pressure (125 mmHg) with a polyurethane foam interface. Therapeutic, II.
Muguregowda, Honnegowda Thittamaranahalli; Kumar, Pramod; Govindarama, Padmanabha Udupa Echalasara
2018-01-01
BACKGROUND Malondialdehyde (MDA) is an oxidant that causes damage to membranes, DNA, proteins, and lipids at the cellular level. Antioxidants minimize the effects of oxidants and thus help in formation of healthy granulation tissues with higher level of hydroxyproline and total protein. This study compared the effect of limited access dressing (LAD) with conventional closed dressing biochemically and histopathologically. METHODS Seventy-two 12-65 years old burn patients with mean wound size of 14 cm2 were divided to two groups of LAD (n=37), and conventional dressing groups (n=35). Various biochemical parameters were measured in granulation tissue. Histopathological analysis of the granulation tissue was studied too. RESULTS LAD group showed significant increase in hydroxyproline, total protein, GSH, and GPx and decrease in MDA levels compared to conventional dressing group. A significant negative correlation between GSH and MDA was noted in LAD group, but in conventional dressing group there was no significant correlation. A significant negative correlation between GPx and MDA was noticed in LAD group, but in conventional dressing group was not significant. There was a histologically fewer inflammatory cells, increased and well organized extracellular matrix deposit, more angiogenesis in LAD group after 10 days while the difference was significant between the groups. CONCLUSION Our study showed a significant reduction in oxidative stress biomarker of MDA, increase in hydroxyproline, total protein, antioxidants and amount of ECM deposition, number of blood vessels and a decrease in the amount of inflammatory cells and necrotic tissues in LAD group indicating the better healing effect of burn wounds. PMID:29651393
Applications of modern sensors and wireless technology in effective wound management.
Mehmood, Nasir; Hariz, Alex; Fitridge, Robert; Voelcker, Nicolas H
2014-05-01
The management of chronic wounds has emerged as a major health care challenge during the 21st century consuming, significant portions of health care budgets. Chronic wounds such as diabetic foot ulcers, leg ulcers, and pressure sores have a significant negative impact on the quality of life of affected individuals. Covering wounds with suitable dressings facilitates the healing process and is common practice in wound management plans. However, standard dressings do not provide insights into the status of the wound underneath. Parameters such as moisture, pressure, temperature and pH inside the dressings are indicative of the healing rate, infection, and wound healing phase. But owing to the lack of information available from within the dressings, these are often changed to inspect the wound, disturbing the normal healing process of wounds in addition to causing pain to the patient. Sensors embedded in the dressing would provide clinicians and nurses with important information that would aid in wound care decision making, improve patient comfort, and reduce the frequency of dressing changes. The potential benefits of this enabling technology would be seen in terms of a reduction in hospitalization time and health care cost. Modern sensing technology along with wireless radio frequency communication technology is poised to make significant advances in wound management. This review discusses issues related to the design and implementation of sensor technology and telemetry systems both incorporated in wound dressings to devise an automated wound monitoring technology, and also surveys the literature available on current sensor and wireless telemetry systems. Copyright © 2013 Wiley Periodicals, Inc.
Composite wound dressings of pectin and gelatin with aloe vera and curcumin as bioactive agents.
Tummalapalli, Mythili; Berthet, Morgane; Verrier, Bernard; Deopura, B L; Alam, M S; Gupta, Bhuvanesh
2016-01-01
Aloe vera and curcumin loaded oxidized pectin-gelatin (OP-Gel) matrices were used as antimicrobial finishes on nonwoven cotton fabrics to produce composite wound care devices. The drug release characteristics of the biocomposite dressings indicated that curcumin is released through a biphasic mechanism - erosion of the polymeric matrix, followed by diffusion, while aloe vera is released upon leaching of the polymeric matrix. A 50/50 composition of aloe vera/curcumin was used to fabricate OP-Gel-Aloe Curcumin dressings. However, contrary to our expectations, OP-Gel-Aloe Curcumin dressings exhibited lesser antimicrobial activity compared to OP-Gel-Aloe and OP-Gel-Curcumin dressings. The cytocompatibility of the fabricated dressings was evaluated using NIH3T3 mouse fibroblast cells. OP-Gel-Aloe treated fibroblasts had the highest viability, with the matrices providing a substrate for good cell attachment and proliferation. On the other hand, OP-Gel-Curcumin and OP-Gel-Aloe Curcumin seemed to have induced apoptosis in NIH3T3 cells. In vivo wound healing analysis was carried out using an excisional splint wound model on C57BL/6J mice. OP-Gel-Aloe treated wounds exhibited very rapid healing with 80% of the wound healing in just 8 days. Furthermore, aloe vera exerted a strong anti-inflammatory effect and prominent scar prevention. Histological examination revealed that an ordered collagen formation and neovascularization could be observed along with migration of nuclei. Therefore, OP-Gel-Aloe biocomposite dressings are proposed as viable materials for effective wound management. Copyright © 2015 Elsevier B.V. All rights reserved.
SU-F-T-379: Dosimetric Impacts of Topical Agents and Dressings On Skin in Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tse, K; Morley, L; Cashell, A
Purpose: This study investigated the superficial dose enhancement in the application of topical agents, clinical materials (thermal mask and bolus) and dressings in megavoltage photon beam radiotherapy. Different topical skin agents, clinical materials and dressings were evaluated and compared for their skin dosimetric impacts on the patients during radiation treatment. Methods: Superficial dose enhancements, or percentage doses with and without the studying materials, were measured using the 6 MV (Field size = 10×10 cm{sup 2}) photon beams produced by a Varian TrueBeam linear accelerator. Twelve topical agents, five dressings (dry and wet conditions) and three clinical materials were studied. Amore » solid water phantom was used with a MOSFET dose detector (TN-1002RD, Thomson and Nielsen Electronic, Ottawa, Ontario, Canada) located under a 1-mm PMMA slab to measure the skin dose. The distance between the radiation source and phantom surface was set to 100 cm in all measurements. The topical agents were distributed evenly with 1.5 mm thickness using our specific sample holder on the phantom surface. Extrapolations were made of 0.5 mm thickness for the agents to provide meaningful clinical value. Results: By comparing surface doses without studying materials, it is found that no topical agents had superficial dose enhancement higher than the clinical materials namely, thermoplastic mask (128%), 5-mm Superflab™ bolus (158%) and 10-mm Superflab™ bolus (171%) regarding the same thickness. Superficial dose enhancement of dry dressing did not exceed 110.5%, while wet dressings produced higher dose enhancements (133% for wet Mepilex lite and 141% for wet Mepilex Ag transfer). Conclusion: It is concluded that the evaluated topical agents and dry dressings did not increase the superficial dose to a concerning level, even using excessive thickness in every fraction of radiation treatment. Wet dressings were found producing the bolus effect, but was still substantially less than applying a thin 5-mm bolus.« less
Ondieki, J G; Khainga, S O; Owilla, F; Nangole, F W
2012-07-01
Wounds have provided a challenge to the clinicians for centuries and this scenario persists to the 21st century. Negative pressure wound therapy (NPWT) is one of the latest additions in wound management. It has been widely adopted in developed countries with foam as the default wound dressing although it has some limitations. To determine the difference in outcomes between the use of gauze versus foam as wound dressing in NPWT for the management of acute traumatic wounds with soft tissue loss. Prospective randomised comparative interventional study. Kenyatta National Hospital Orthopaedic and Surgical wards. All patients aged above 12 years with Class III and Class IV acute traumatic wounds. The main outcome measure is the time taken to achieve 100% wound granulation. Comparisons were also made on the mean pain scores during dressing change and the percentage change in wound surface area. Wounds took an average of 8.4 days in the gauze group and 8.1 days in the foam group (p = 0.698) to achieve full granulation. The percentage change in wound surface area was 5.3 versus 5.5 (P = 0.769) in the gauze and foam groups respectively. The infection rates were comparable between the two groups (28% for gauze and 23.1% for foam, p = 0.697) and there was no significant difference in the median pain scores (gauze = 4.5, foam = 4.8 with p = 0.174). However, outcomes with gauze dressing were influenced significantly by the time to application of NPWT, initial wound surface area and wound infection while with foam dressing outcomes tended to be affected less so by the above factors. In the use of NPWT for the management of acute traumatic wounds, there is no difference in terms of time to full wound granulation, change in wound surface area, wound infection and pain during dressing change whether gauze or foam is used as the wound dressing material.
Meekul, Jarernchon; Chotirosniramit, Arnon; Himakalasa, Woraluck; Orrapin, Saritphat; Wongthanee, Antika; Pongtam, Orapin; Kulprachakarn, Kanokwan; Rerkasem, Kittipan
2017-06-01
Necrotizing fasciitis (NF) is a high morbidity and mortality disease and also demands high economic resources. The standard treatment of NF is surgical debridement and proper dressing for wound bed preparation. The efficacy of silver alginate dressing can inhibit the growth of microorganisms and keep the environment clean for wound bed preparation. However an optimal dressing to manage such wounds has yet to emerge. NF patients who were admitted between April 2013 and May 2016 were randomized to have wound dressing using either silver dressing (Ag group) or normal saline solution gauze (NSS group). The 4 main outcomes for comparison between the 2 groups were the duration of wound bed preparation, total cost during hospital stay, the duration of hospital stay, and the pain score. Thirty-nine patients were included in the study: 19 patients in the NSS group and 20 patients in the Ag group. The mean duration of wound bed preparation in the NSS group was 31.87 days, and in Ag group it was 21.39 days, but this trend was not statistically significant ( P = .057). The mean cost of treatment in the NSS and Ag groups was not significantly different ( P = .434; US$3308.83 and US$2647.82, respectively). The duration of hospital days in the 2 groups was not significantly different either (29.19 days [NSS group] and 20.99 days [Ag group]; P = .222). The pain score was significantly lower in the Ag group than those in the NSS group. Although silver dressing seems to be expensive, the cost of total treatment during hospital stay and the duration of hospital stay were not significantly different between groups. However, the mean duration of wound bed preparation seems to trend favoring toward the silver dressing group.
Thilmann, C; Adamietz, I A; Ramm, U; Mose, S; Saran, F; Böttcher, H D
1996-05-01
Silicone-coated polyamide wound dressing is frequently used for the supportive treatment in patients with radiation induced skin lesions. The use of this kind of dressing during radiotherapy with high energy beams shifts the dose built-up effect towards the skin surface. Thus the dose delivered to the skin increases. The present work quantifies changes of the skin dose by a commercial silicon-coated polyamide wound dressing. The dependence on the beam quality and on different treatment techniques is investigated. Measurements were performed with photon (60Co, 6 MV, 42 MV) and electron (7 MeV, 20 MeV, 40 MeV) beams using thin LiF thermoluminescence dosimeters (TLD) in a perspex phantom. The beams were directed perpendicularly to the phantom surface. For 60Co and 6 MV photon beams the skin dose was evaluated in vivo at different beam arrangements and at a given reference dose. For 60Co, 6 MV and 42 MV photon beams wound dressing caused a dose increase on the surface of the perspex phantom by a factor of 1.65, 1.39 and 1.33 respectively. Using oblique or rotational techniques for 60Co and 6 MV photon irradiation the wound dressing increased the skin dose but less compared to perpendicular beam direction. For electron beams the skin dose is relatively high (from 84% to 92%) and an increase by a dressing has no clinical relevance (factor 1.03 to 1.05). The silicone-coated polyamide wound dressing causes no relevant skin dose increase during radiation treatment with electron beams and can be left on the skin during irradiation. During radiation treatment with photon beams like 60Co and 6 MV the protective procedure should be adapted to skin changes, in case of strong skin reactions a removal during the time of irradiation should be considered.
Bennett, Brad L; Littlejohn, Lanny F; Kheirabadi, Bijan S; Butler, Frank K; Kotwal, Russ S; Dubick, Michael A; Bailey, Jeffrey A
2014-01-01
Hemorrhage remains the leading cause of combat death and a major cause of death from potentially survivable injuries. Great strides have been made in controlling extremity hemorrhage with tourniquets, but not all injuries are amenable to tourniquet application. Topical hemostatic agents and dressings have also contributed to success in controlling extremity and compressible junctional hemorrhage, and their efficacy continues to increase as enhanced products are developed. Since the addition of Combat Gauze™ (Z-Medica Corporation, Wallingford, CT, USA; http://www.z-medica.com/) in April 2008 to the Tactical Combat Casualty Care (TCCC) Guidelines, there are consistent data from animal studies of severe hemorrhage that chitosan-based hemostatic gauze dressings developed for battlefield application are, at least, equally efficacious as Combat Gauze. Successful outcomes are also reported using newer chitosan-based dressings in civilian hospital-based surgical case reports and prehospital (battlefield) case reports and series. Additionally, there have been no noted complications or safety concerns in these cases or across many years of chitosan-based hemostatic dressing use in both the military and civilian prehospital sectors. Consequently, after a decade of clinical use, there is added benefit and a good safety record for using chitosan-based gauze dressings. For these reasons, many specific US military Special Operations Forces, NATO militaries, and emergency medical services (EMS) and law enforcement agencies have already implemented the widespread use of these new recommended chitosan-based hemostatic dressings. Based on the past battlefield success, this report proposes to keep Combat Gauze as the hemostatic dressing of choice along with the new addition of Celox™ Gauze (Medtrade Products Ltd., Crewe, UK; http://www.celoxmedical.com/usa/products /celox-gauze/) and ChitoGauze® (HemCon Medical Technologies, Portland, OR, USA; http://www.hemcon.com/) to the TCCC Guidelines. 2014.
Cabañas, R; Calderón, O; Ramírez, E; Fiandor, A; Caballero, T; Heredia, R; Herranz, P; Madero, R; Quirce, S; Bellón, T
2018-03-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) is a severe delayed hypersensitivity reaction. The determination of drug causality is complex. The lymphocyte transformation test (LTT) has been reported positive in more than 50% of DRESS cases. Nevertheless, the sensitivity and specificity of LTT specifically in DRESS have not yet been established. Rechallenge with the culprit drug is contraindicated and cannot be used as gold standard for sensitivity and specificity determination. To estimate the sensitivity and specificity of LTT in a clinically defined series of patients with DRESS. Some 41 patients diagnosed with DRESS were included in the study. The results of the algorithm of the Spanish Pharmacovigilance System were used as the standard for a correct diagnosis of drug causality. A standard LTT was performed with involved drugs in acute or recovery samples. A stimulation index (SI) ≥2 in at least one concentration except for beta-lactams (SI ≥3) and contrast media (SI ≥4) was considered positive. Contingency tables and ROC curves were used for analysis. Sensitivity and specificity of LTT in the recovery phase of DRESS were 73% and 82%, respectively, whereas in the acute phase, they were only 40% and 30%, respectively. Comparison of skin tests and LTT confirmed a higher sensitivity and specificity of LTT in DRESS. LTT showed high sensitivity (S) and specificity (Sp) for anticonvulsants (S 100%, Sp 100%; P = .008), anti-TB drugs (S 87.5%, Sp 100%; P = .004), and beta-lactams (S 73%, Sp 100%; P = .001). ROC curves revealed that the best criteria for LTT positivity for all drugs are SI ≥2 in at least one concentration, increasing overall sensitivity to 80%, and for beta-lactams from 73% to 92%. LTT is a good diagnostic tool for drug causality in DRESS, mainly when performed in the recovery phase. © 2017 John Wiley & Sons Ltd.
Dynamical coupled-channels study of {pi}N {right arrow} {pi pi}N reactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamano, H.; Julia-Diaz, B.; Lee, T.-S. H.
As a step toward performing a complete coupled-channels analysis of the world data of {pi}N,{gamma}*N {yields} {pi}N,{eta}N,{pi}{pi}N reactions, the {pi}N {yields} {pi}{pi}N reactions are investigated starting with the dynamical coupled-channels model developed in Phys. Rev. C 76, 065201 (2007). The channels included are {pi}N,{eta}N, and {pi}{pi}N which has {pi}{Delta},{rho}N, and {sigma}N resonant components. The nonresonant amplitudes are generated from solving a set of coupled-channels equations with the meson-baryon potentials defined by effective Lagrangians. The resonant amplitudes are generated from 16 bare excited nucleon (N*) states that are dressed by the nonresonant interactions as constrained by the unitarity condition. The datamore » of total cross sections and {pi}N and {pi}{pi} invariant mass distributions of {pi} + p {yields} {pi} + {pi} + n, {pi} + {pi}0p and {pi} - p {yields} {pi} + {pi} - n, {pi} - {pi}0p,{pi}0{pi}0n reactions from threshold to the invariant mass W = 2 GeV can be described to a very large extent. We show the importance of the coupled-channels effects and the strong interference among the contributions from the {pi}{Delta},{sigma}N, and {rho}N channels. The large interference between the resonant and nonresonant amplitudes is also demonstrated. Possible future developments are discussed.« less
Low-frequency approximation for high-order harmonic generation by a bicircular laser field
NASA Astrophysics Data System (ADS)
Milošević, D. B.
2018-01-01
We present low-frequency approximation (LFA) for high-order harmonic generation (HHG) process. LFA represents the lowest-order term of an expansion of the final-state interaction matrix element in powers of the laser-field frequency ω . In this approximation the plane-wave recombination matrix element which appears in the strong-field approximation is replaced by the exact laser-free recombination matrix element calculated for the laser-field dressed electron momenta. First, we have shown that the HHG spectra obtained using the LFA agree with those obtained solving the time-dependent Schrödinger equation. Next, we have applied this LFA to calculate the HHG rate for inert gases exposed to a bicircular field. The bicircular field, which consists of two coplanar counter-rotating fields having different frequencies (usually ω and 2 ω ), is presently an important subject of scientific research since it enables efficient generation of circularly polarized high-order harmonics (coherent soft x rays). Analyzing the photorecombination matrix element we have found that the HHG rate can efficiently be calculated using the angular momentum basis with the states oriented in the direction of the bicircular field components. Our numerical results show that the HHG rate for atoms having p ground state, for higher high-order harmonic energies, is larger for circularly polarized harmonics having the helicity -1 . For lower energies the harmonics having helicity +1 prevails. The transition between these two harmonic energy regions can appear near the Cooper minimum, which, in the case of Ar atoms, makes the selection of high-order harmonics having the same helicity much easier. This is important for applications (for example, for generation of attosecond pulse trains of circularly polarized harmonics).
Index of refraction engineering in five-level dressed interacting ground states atoms.
Sagona-Stophel, Steven A; Weatherall, James Owen; Search, Christopher P
2011-08-15
We present a five-level atomic system in which the index of refraction of a probe laser can be enhanced or reduced below unity with vanishing absorption in the region between pairs of absorption and gain lines formed by dressing of the atoms with a control laser and rf/microwave fields. By weak incoherent pumping of the population into a single metastable state, one can create several narrow amplifying resonances. At frequencies between these gain lines and additional absorption lines, there exist regions of vanishing absorption but resonantly enhanced index of refraction. In Rb vapors with density N in units of cm(-3), we predict an index of refraction up to n≈√(1+1.2×10(-14)N) for the D1 line, which is more than an order of magnitude larger than other proposals for index of refraction enhancement. Furthermore, the index can be readily reduced below 1 by simply changing the sign of the probe or rf field detunings. This enhancement is robust with respect to homogeneous and inhomogeneous broadening. © 2011 Optical Society of America
Engelhardt, Paul E; Nigg, Joel T; Ferreira, Fernanda
2017-07-01
In the current study, we examined the role of intelligence and executive functions in the resolution of temporary syntactic ambiguity using an individual differences approach. Data were collected from 174 adolescents and adults who completed a battery of cognitive tests as well as a sentence comprehension task. The critical items for the comprehension task consisted of object/subject garden paths (e.g., While Anna dressed the baby that was small and cute played in the crib), and participants answered a comprehension question (e.g., Did Anna dress the baby?) following each one. Previous studies have shown that garden-path misinterpretations tend to persist into final interpretations. Results showed that both intelligence and processing speed interacted with ambiguity. Individuals with higher intelligence and faster processing were more likely to answer the comprehension questions correctly and, specifically, following ambiguous as opposed to unambiguous sentences. Inhibition produced a marginal effect, but the variance in inhibition was largely shared with intelligence. Conclusions focus on the role of individual differences in cognitive ability and their impact on syntactic ambiguity resolution.
Engelhardt, Paul E.; Nigg, Joel T.; Ferreira, Fernanda
2016-01-01
In the current study, we examined the role of intelligence and executive functions in the resolution of temporary syntactic ambiguity using an individual differences approach. Data were collected from 174 adolescents and adults who completed a battery of cognitive tests as well as a sentence comprehension task. The critical items for the comprehension task consisted of object/subject garden paths (e.g., While Anna dressed the baby that was small and cute played in the crib), and participants answered a comprehension question (e.g., Did Anna dress the baby?) following each one. Previous studies have shown that garden-path misinterpretations tend to persist into final interpretations. Results showed that both intelligence and processing speed interacted with ambiguity. Individuals with higher intelligence and faster processing were more likely to answer the comprehension questions correctly and, specifically, following ambiguous as opposed to unambiguous sentences. Inhibition produced a marginal effect, but the variance in inhibition was largely shared with intelligence. Conclusions focus on the role of individual differences in cognitive ability and their impact on syntactic ambiguity resolution. PMID:27150661
Arefiev, Katharine; Warycha, Melanie; Whiting, Dennis; Alam, Murad
2012-10-01
Surgical fires are a rare, but serious complication of dermatologic procedures involving electrosurgical and laser devices. Given the lack of data regarding basic fire safety principles, many dermatologists remain unaware of this potential risk. We evaluated the flammability of topical preparations and surgical drapes commonly encountered in the immediate operative field during cutaneous and laser surgery. Surgical dressings, drapes, and pork belly skin were examined for fire risk upon exposure to isopropyl alcohol, chlorhexidine gluconate, and aluminum chloride under dry, saturated, and damp conditions. Both electrosurgery and a carbon-dioxide laser were used as ignition sources. At least some char was observed in 86 of 126 simulated conditions (68%). Flames occurred in 2 test conditions: dry underpad drapes and cotton balls exposed to the carbon-dioxide laser. In general, drapes and dressings dampened or saturated with isopropyl alcohol failed to ignite with electrofulguration or electrodessication, although sparks and moderate char developed on pork belly skin and the underpad drape. Materials dampened or saturated with chlorhexidine gluconate, which contains isopropyl alcohol, generated less smoke and char compared with materials exposed to aluminum chloride, which does not contain alcohol. Future studies may assess the flammability of materials in the setting of oxygen supplementation. In common cutaneous surgical environments, electrosurgery or ablative laser may lead to char and rarely to fire. Char may be seen in up to two thirds of simulated conditions, and in a minute proportion of conditions, fire is observed. Copyright © 2012 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Moon, Mikyung; Lee, Soo-Kyoung
2017-01-01
The purpose of this study was to use decision tree analysis to explore the factors associated with pressure ulcers (PUs) among elderly people admitted to Korean long-term care facilities. The data were extracted from the 2014 National Inpatient Sample (NIS)-data of Health Insurance Review and Assessment Service (HIRA). A MapReduce-based program was implemented to join and filter 5 tables of the NIS. The outcome predicted by the decision tree model was the prevalence of PUs as defined by the Korean Standard Classification of Disease-7 (KCD-7; code L89 * ). Using R 3.3.1, a decision tree was generated with the finalized 15,856 cases and 830 variables. The decision tree displayed 15 subgroups with 8 variables showing 0.804 accuracy, 0.820 sensitivity, and 0.787 specificity. The most significant primary predictor of PUs was length of stay less than 0.5 day. Other predictors were the presence of an infectious wound dressing, followed by having diagnoses numbering less than 3.5 and the presence of a simple dressing. Among diagnoses, "injuries to the hip and thigh" was the top predictor ranking 5th overall. Total hospital cost exceeding 2,200,000 Korean won (US $2,000) rounded out the top 7. These results support previous studies that showed length of stay, comorbidity, and total hospital cost were associated with PUs. Moreover, wound dressings were commonly used to treat PUs. They also show that machine learning, such as a decision tree, could effectively predict PUs using big data.
Zhang, Jin; Wang, Minyan; Cao, Yucheng; Liang, Peng; Wu, Shengchun; Leung, Anna Oi Wah; Christie, Peter
2017-04-01
Rice cultivation requires large quantities of irrigation water and mineral fertilizers. This provides an opportunity for the recycling of the plant nutrients in anaerobically digested pig slurry, large amounts of which are generated in Chinese pig farms. Hence, to promote the sustainable development of livestock and poultry breeding and rice production, a micro-plot field experiment was carried out to assess whether or not slurry can replace mineral fertilizers in rice paddy production in terms of plant tillering, grain quality, and yields. The results indicate that the total N content of the slurry can serve as an alternative source of N when compared to the control (450 kg ha -1 commercial compound fertilizer (N/P 2 O 5 /K 2 O = 15:15:15) as basal fertilizer, 300 kg ha -1 urea (N% = 46), and 150 kg ha -1 commercial compound fertilizer as top-dressed fertilizer). No negative effects on plant growth or grain yield were observed, although there may be a potential risk due to an increase in grain Cu concentration. The amylose content and gel consistency of the rice grains were enhanced significantly by the use of slurry as a basal fertilizer, but the grain protein and total amino acid contents decreased. The results suggest that anaerobically digested pig slurry can replace mineral fertilizers in rice production when applied as a basal dressing together with urea and commercial compound fertilizer as top-dressed fertilizers.
Vignesh, Pandiarajan; Kishore, Janak; Kumar, Ankur; Vinay, Keshavamurthy; Dogra, Sunil; Sreedharanunni, Sreejesh; Prasun Giri, Prabhas; Pal, Priyankar; Ghosh, Apurba
2017-05-01
Drug rash, eosinophilia, and systemic symptoms (DRESS) syndrome is a severe systemic hypersensitivity reaction that usually occurs within 6 weeks of exposure to the offending drug. Diagnosis is usually straightforward in patients with pyrexia, skin rash, hepatitis, and eosinophilia with a preceding history of exposure to agents often associated with DRESS syndrome, such as aromatic anticonvulsants and sulfa drugs, but diagnosis of DRESS may still be a challenge. We report a 4-year-old child with probable DRESS syndrome complicated by multiple hematologic complications that developed 1 month after exposure to fluoxetine, a drug not known to be associated with such severe reactions. © 2017 Wiley Periodicals, Inc.
Reducing pain in acute herpes zoster with plain occlusive dressings: a case report.
Keegan, David A
2015-04-25
The pain of acute herpes zoster (shingles) is severe and difficult to control. The medications used to control pain have a variety of important and potentially serious side effects. To the best of my knowledge, this is the first case report of using a plain topical occlusive dressing to reduce the pain of herpes zoster, avoiding the use of medication. A 40-year-old Caucasian man and a qualified physician (the author), developed a dermatomal vesicular rash consistent with herpes zoster. Applying plain topical occlusive dressings reduced the severity of his pain to an ignorable level. Plain topical occlusive dressings provide effective pain relief for acute herpes zoster, thereby avoiding the risks accompanying medication use.
NASA Astrophysics Data System (ADS)
Laloy, Julie; Haguet, Hélène; Alpan, Lutfiye; Mancier, Valérie; Mejia, Jorge; Levi, Samuel; Dogné, Jean-Michel; Lucas, Stéphane; Rousse, Céline; Fricoteaux, Patrick
2017-08-01
Copper/silver core/shell nanopowders with different metal ratio have been elaborated by electrochemistry (ultrasound-assisted electrolysis followed by a displacement reaction). Characterization was performed by several methods (X-ray diffraction, scanning electron microscope, energy-dispersive X-ray spectroscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, centrifugal liquid sedimentation, and zeta potential measurements). The mean diameter of all nanoparticles is around 10 nm. The impact of each nanopowder on hemolysis, platelet aggregation, and coagulation has been studied on whole human blood. Hemolysis assays were performed with spectrophotometric measurement and platelet aggregation, with light transmission aggregometry and was compared to Cu/Pt core/shell nanoparticles with similar size as negative control. Calibrated thrombin generation test has been used for a coagulation study. They neither impact platelet aggregation nor hemolysis and have a procoagulant effect whatever their composition (i.e., metal ratio). These results highlight that such nanopowders have a potential use in medical applications (e.g., wound dressing).
Dressed photons from the viewpoint of photon localization: the entrance to the off-shell science
NASA Astrophysics Data System (ADS)
Saigo, Hayato; Ojima, Izumi; Ohtsu, Motoichi
2017-12-01
In the present paper, a new aspect of the interplay is examined between mathematical-physical arguments and light-matter fusion technologies in terms of the concept of "effective mass", starting from a question: Who has seen a free photon? Owing to the general results due to Newton-Wigner and to Wightman, a position operator is absent for massless free particles with non-zero finite spins, and hence, we cannot observe free photons in any local space regions. To solve this paradox of "photon localization", the effective mass of a photon needs to be generated through the couplings of photons with matter. Here "polaritons" picture as a basic notion in optical and solid physics is shown to verify this viewpoint, which is seen to apply also to more general settings . Focusing on the role played by nanoparticles, we reach a new look at the notion of "dressed photons" as off-shell particles. The perspective above shows that essential mathematical structure of quantum field theory for the so-called elementary particles in subatomic scale can also be applied to certain phenomena in the nano-scale.
Kazanavičius, M; Cepas, A; Kolaityte, V; Simoliuniene, R; Rimdeika, R
2017-06-02
To identify the most appropriate, most suitable and most efficient dressing for split-thickness skin graft (STSG) donor sites. Comparing the wound healing rate, pain severity and duration, as well as the dressing change frequency in four randomised patient groups. A single-centre non-blinded randomised controlled trial was carried out during 2010-2014. All patients treated for skin defects/lesions (due to burns, trauma or ulcers) using STSG were included in the study. All patients were randomly allocated in four different donor site treatment groups; polyurethane (PU group, Mepilex); polyurethane with silicone membrane (PUSM group; Mepilex border,); transparent, breathable film (TBF group; Mepitel film) and cotton gauze dressings (CG group) using Excel 2007. We evaluated: wound healing time, pain severity and duration, the frequency of dressing change, donor site re-epithelialisation, donor site complications (signs of inflammation or infection). Patients were assessed on postoperative days: 1, 3, 6, 9, 12, 15, 18 and 21. After random allocation of study participants the number of patients in each group were: PU group n=25; PUSM group n=24; TBF group n=24; CG group n=25. The groups were homogenous according to gender, age, main pathology, donor site area and wound size. The STSG donor site healing time varied from 9 to 21 days. The mean healing time in the CG group was 14.76 days, whereas in the PU, PUSM, and TBF group it was significantly shorter; 12.25 days, 11.63 days and 10 days, respectively. Patients in the TBF group demonstrated the most rapid healing time with 66.7% of STSG donor sites healed by postoperative day 9. The pain duration interval in modern dressing groups (PU, PUSM and TBF groups) was 0-9 days, whereas it was 6-18 day in the CS group. Pain intensity mean on postoperative day 1 was 2.21 in the PU group; 1.67 in the PUSM group; 1.46 in the TBF group and 3.04 in the CG group. The average pain duration in Group PU, PUSM, and TBF was 4.08 days; 2.5 days; 2.29 days, respectively. The average number of times each dressing was changed in each group was, 2.83 times in the PU group and PUSM group and 1.46 times in the TBF group. The CG dressing group were changed once when the donor site wound re-epithelialised. There was one patient in the PU group who experienced signs of infection, was treated accordingly and excluded from the study. The fastest healing time was demonstrated by patients in the TBF group. The pain was not as severe and for a shorter period of time in modern dressing study groups. However, the pain was lightest and felt shortest in TBF dressing group. The modern dressings PU and PUSM had to be changed more frequently than TBF.
Topical phenytoin for treating pressure ulcers.
Hao, Xiang Yong; Li, Hong Ling; Su, He; Cai, Hui; Guo, Tian Kang; Liu, Ruifeng; Jiang, Lei; Shen, Yan Fei
2017-02-22
Pressure ulcers are common in clinical practice and pose a significant health problem worldwide. Apart from causing suffering to patients, they also result in longer hospital stays and increase the cost of health care. A variety of methods are used for treating pressure ulcers, including pressure relief, patient repositioning, biophysical strategies, nutritional supplementation, debridement, topical negative pressure, and local treatments including dressings, ointments and creams such as bacitracin, silver sulphadiazine, neomycin, and phenytoin. Phenytoin is a drug more commonly used in the treatment of epilepsy, but may play an important role in accelerating ulcer healing. To assess the effects of topical phenytoin on the rate of healing of pressure ulcers of any grade, in any care setting. In September 2016, we searched the following electronic databases to identify relevant randomized clinical trials: the Cochrane Wounds Specialised Register; the Cochrane Central Register of Controlled Trials (CENTRAL; the Cochrane Library); Ovid MEDLINE; Ovid Embase; and EBSCO CINAHL Plus. We handsearched conference proceedings from the European Pressure Ulcer Advisory Panel, European Wound Management Association and the Tissue Viability Society for all available years. We searched the references of the retrieved trials to identify further relevant trials. We also searched clinical trials registries to identify ongoing and unpublished studies. There were no restrictions with respect to language, date of publication or study setting. We included all randomized controlled trials (RCTs) addressing the effects (both benefits and harms) of topical phenytoin on the healing of pressure ulcers of any grade compared with placebo or alternative treatments or no therapy, irrespective of blinding, language, and publication status. Two review authors independently selected studies, extracted information on participants, interventions, methods and results and assessed risk of bias using Cochrane methodological procedures. For dichotomous variables, we calculated the risk ratio (RR) with 95% confidence interval (CI). For continuous variables, we calculated the mean difference with 95% CI. We rated the quality of the evidence by using Grading of Recommendations, Assessment, Development and Evaluation approach (GRADE). Three small RCTs met our inclusion criteria and included a total of 148 participants. These compared three treatments with topical phenytoin: hydrocolloid dressings, triple antibiotic ointment and simple dressings. In the three RCTs, 79% of participants had grade II ulcers, and 21% of participants had grade I ulcers; no participants had grade III or IV ulcers. Two RCTs had a high risk of bias overall and the other RCT was at unclear risk of bias due to poor reporting. Two RCTs had three intervention arms and the other had two intervention arms.Two studies compared topical phenytoin with hydrocolloid dressing (84 participants analysed). The available data suggest that hydrocolloid dressings may improve ulcer healing compared to topical phenytoin (39.3% ulcers healed for phenytoin versus 71.4% ulcers healed for hydrocolloid dressings (RR 0.55, 95% CI 0.33 to 0.92; 56 participants, 1 study; low quality evidence). We downgraded the evidence twice: once due to serious limitations (high risk of bias) and once due to the small sample size and small number of events. Two studies compared topical phenytoin with simple dressings (81 participants analysed). From the available data, we are uncertain whether topical phenytoin improves ulcer healing compared to simple dressings (39.3% ulcers healed for phenytoin versus 29.6% ulcers healed for the simple dressing (RR 1.33, 95% CI 0.63 to 2.78; 55 participants, 1 study; very low quality evidence). This evidence was downgraded once due to serious limitations (high risk of bias) and twice due to the low number of outcome events and resulting wide CI which included the possibility of both increased healing and reduced healing. We therefore considered it to be insufficient to determine the effect of topical phenytoin on ulcer healing. One study compared topical phenytoin with triple antibiotic ointment, however, none of the outcomes of interest to this review were reported. No adverse drug reactions or interactions were detected in any of the three RCTs. Minimal pain was reported in all groups in one trial that compared topical phenytoin with hydrocolloid dressings and triple antibiotic ointment. This review has considered the available evidence and the result shows that it is uncertain whether topical phenytoin improves ulcer healing for patients with grade I and II pressure ulcers. No adverse events were reported from three small trials and minimal pain was reported in one trial. Therefore, further rigorous, adequately powered RCTs examining the effects of topical phenytoin for treating pressure ulcers, and to report on adverse events, quality of life and costs are necessary.
Yunoki, Shunji; Kohta, Masushi; Ohyabu, Yoshimi; Iwasaki, Tetsuji
2015-01-01
This study evaluated the in vitro antibacterial activity and cytotoxicity of various commercially available silver-containing dressings (Ag dressing). Biohesive Ag (hydrocolloid, silver sulfadiazine), Aquacel® Ag (nonwoven fabric, ionic silver [Ag]), Algisite™ Ag (nonwoven fabric, Ag), Mepilex® Ag (foam, silver sulfate), and PolyMem® Ag (foam, nanocrystalline silver) were tested for characteristics of Ag release, antibacterial activity, and cytotoxicity. The release of Ag was investigated in cell culture medium at immersion periods of 6, 24, and 48 hours. The antibacterial activity against Staphylococcus aureus and Pseudomonas aeruginosa were accessed by a disc diffusion test. The cytotoxicity was evaluated using V79 cells, by an extraction method. The cytotoxicity was not a monotonic function of the antibacterial activity among the Ag dressings and could not be simply explained by Ag-release properties. Biohesive Ag was regarded as a slow-release Ag dressing, showing the lowest cytotoxicity, while the antibacterial activity was classified as "strong" or "significant" against the two species of bacteria. Aquacel Ag and Algisite Ag showed higher antibacterial activity and cytotoxic effects, which were supported by the higher Ag release. Mepilex Ag showed the highest release of Ag, and the cytotoxicity was the highest among the Ag dressings. However, the antibacterial activity was classified as "significant" or "no activity" for P. aeruginosa and S. aureus, respectively. PolyMem Ag showed the lowest Ag release, and the antibacterial activity classified as "significant" or "no activity" for S. aureus and P. aeruginosa, respectively, whereas the cytotoxicity was similar to those of Aquacel Ag and Algisite Ag. The efficacy and adverse effects of the Ag dressings revealed differences that should be considered by clinicians during wound management.
Evaluation of Six Split-thickness Skin Graft Donor-site Dressing Materials in a Swine Model
Masella, Pamela C.; Balent, Eric M.; Carlson, Terri L.; Lee, Karen W.
2013-01-01
Background: Numerous dressings for split-thickness skin graft donor sites are commercially available with no conclusive evidence-based consensus regarding the optimal dressing choice. This study was conducted to identify which of 5 commonly used materials promotes wound healing most effectively for use on split-thickness donor sites in comparison with our standard dressing, Xeroform (petrolatum gauze). Methods: Twenty-four partial-thickness wounds were created on the backs of 4 pigs using a dermatome. Wounds (n = 4 per dressing type per pig) were treated with Xeroform, Opsite (polyurethane film), Kaltostat ( calcium sodium alginate), DuoDERM (hydrocolloid), Aquacel (hydrofiber), and Mepilex (silicone foam). Full-thickness skin samples were excised at 3 or 5 days and evaluated histologically for reepithelialization and inflammation. Comparisons also included incidence of infection, ease of use, and cost analyses. Results: DuoDERM elicited the greatest percent reepithelialization (81%) and Mepilex the lowest (33%) after 3 days (P = 0.004). All dressings demonstrated complete reepithelialization except Mepilex (85%) at 5 days. There were no infections and inflammation was mild among all treatments. Mepilex was easiest to use, whereas Aquacel, Kaltostat, and Opsite were most difficult (P = 0.03). Xeroform was most cost-effective and Aquacel most expensive. Combined scoring revealed DuoDERM = Xeroform > Opsite = Mepilex > Kaltostat > Aquacel. Conclusions: DuoDERM and Xeroform were most effective overall. DuoDERM tended to outperform all dressings in reepithelialization at 3 days, while Xeroform was least expensive, easy to use, and demonstrated rapid reepithelialization. These findings suggest that Xeroform may be preferred for use on large donor-site areas. DuoDERM may be more appropriate for small donor sites when healing time is a priority. PMID:25289278
Does the Use of Clean or Sterile Dressing Technique Affect the Incidence of Wound Infection?
Kent, Dea J; Scardillo, Jody N; Dale, Barbara; Pike, Caitlin
The purpose of this article is to examine the evidence and provide recommendations for the use of clean or sterile dressing technique with dressing application to prevent wound infection. In all persons with acute or chronic wounds, does the use of clean or sterile dressing technique affect incidence of wound infection? A search of the literature was performed by a trained university librarian, which resulted in 473 articles that examined any age group that dealt with application of a wound dressing using either sterile or nonsterile technique. A systematic approach was used to review titles, abstracts, and text, yielding 4 studies that met inclusion criteria. Strength of the evidence was rated using rating methodology from Essential Evidence Plus: Levels of Evidence and Oxford Center for Evidence-Based Medicine, adapted by Gray and colleagues. Johns Hopkins Nursing Evidence-Based Practice Nursing Research Appraisal Tool was used to rate the quality of the evidence. All 4 studies reported no significant difference in the rate of wound infection when using either clean or sterile technique with dressing application. The strength of the evidence for the identified studies was identified as level 2 (1 level A, 3 level B). The study sizes were variable, and the wounds included do not represent the continuum of wounds clinically encountered across the board. Evidence indicates that the use of clean technique for acute wound care is a clinically effective intervention that does not affect the incidence of infection. There is no recommendation that can be made regarding type of dressing technique for a chronic wound due to the lack of evidence in the literature.
Evaluation of Antimicrobial and Healing Activities of Frog Skin on Guinea Pigs Wounds
Rezazade Bazaz, Mahere; Mashreghi, Mohammad; Mahdavi Shahri, Nasser; Mashreghi, Mansour; Asoodeh, Ahmad; Behnam Rassouli, Morteza
2015-01-01
Background: Frog skin secretions have potentials against a wide spectrum of bacteria. Also, frog skin compositions have healing properties. Objectives: The aim of this study was to investigate the antibacterial potentials along with healing properties of frog skin Rana ridibunda, a species which thoroughly lives in Iran marshes, as a biological dressing on wounds. Materials and Methods: In this study, excisional wounds, dressed with frog skin, were compared between experimental and control groups of guinea pigs. In the experimental groups, wounds were dressed with the dermal (FS) and epidermal (RFS) sides of fresh frog R. ridibunda skin, while only usual cotton gauze covered the wounds of the control group. Furthermore, microbial samples were taken on different days (0, 3, 5, and 7 days post injury) to count the number of the colony-forming units. Additionally, the microbial penetration test was performed on frog skin and then the progression of wound closure was evaluated. Results: In the microbial studies, the bacterial load considerably declined in the wounds treated with FS and RFS compared with the control wounds. On day 7 post injury, the numbers of the colony-forming units for the FS, RFS, and control groups were 6.75, 105, and 375, respectively. In the penetration test, fresh frog skin showed to be a bacterial resistant dressing. The results revealed that the rate of wound closure in the experimental groups significantly was accelerated in comparison with that in the control group. Conclusions: Our results demonstrated the antimicrobial properties of frog skin as a wound dressing, which has antimicrobial effects per se. This biological dressing shows promise as an effective biological wound dressing insofar as not only is it capable of resisting microbes and accelerating wound healing but also it is cost-effective and easy to use. PMID:26468364
Kellar, Robert S; Audet, Robert G; Roe, David F; Rheins, Lawrence A; Draelos, Zoe Diana
2013-06-01
As oxygen is essential for wound healing and there is limited diffusion across the stratum corneum into the epidermis, we wanted to evaluate whether the topical delivery of a total dissolved oxygen in dressing form on intact human subject skin would improve clinical and histologic skin functioning. Fifty normal, healthy subjects completed a pilot clinical evaluation to assess the efficacy and tolerability of a dissolved oxygen dressing (OxygeneSys™-Continuous) to improve the health and appearance of intact skin. Clinical analysis was performed on 50 subjects; histological and gene expression analysis was performed on 12 of the 50 subjects to assess the effect of the dissolved oxygen dressing. Clinical data demonstrate that the dressing is well tolerated, and several measures of skin health and integrity showed improvements compared with a control dressing site. Skin hydration measurements showed a statistically significant increase in skin hydration at 0-4, 4-8, and 0-8 weeks (P < 0.05 at each time point). The blinded clinical investigator's grading of desquamation, roughness, and skin texture show significant decreases from baseline to the 8-week time point (P < 0.05). The dressings were removed prior to the blinded clinical investigator's grading. These data were supported by the histological and gene expression studies, which showed a general reduction in inflammatory response markers and transcription products (IL-6, IL-8, TNF-alpha, MMP-1, and MMP-12), while facilitating a general increase in structural skin proteins (collagen I, elastin, and filaggrin). Additionally, p53 signals from biopsy samples support the clinical investigator's observations of no safety concerns. The data from this study demonstrate that the dressing has no deleterious effects and stimulates beneficial effects on intact, nonwounded skin. © 2013 Wiley Periodicals, Inc.
Wound Dressings and Comparative Effectiveness Data
Sood, Aditya; Granick, Mark S.; Tomaselli, Nancy L.
2014-01-01
Significance: Injury to the skin provides a unique challenge, as wound healing is a complex and intricate process. Acute wounds have the potential to move from the acute wound to chronic wounds, requiring the physician to have a thorough understanding of outside interventions to bring these wounds back into the healing cascade. Recent Advances: The development of new and effective interventions in wound care remains an area of intense research. Negative pressure wound therapy has undoubtedly changed wound care from this point forward and has proven beneficial for a variety of wounds. Hydroconductive dressings are another category that is emerging with studies underway. Other modalities such as hyperbaric oxygen, growth factors, biologic dressings, skin substitutes, and regenerative materials have also proven efficacious in advancing the wound-healing process through a variety of mechanisms. Critical Issues: There is an overwhelming amount of wound dressings available in the market. This implies the lack of full understanding of wound care and management. The point of using advanced dressings is to improve upon specific wound characteristics to bring it as close to “ideal” as possible. It is only after properly assessing the wound characteristics and obtaining knowledge about available products that the “ideal” dressing may be chosen. Future Directions: The future of wound healing at this point remains unknown. Few high-quality, randomized controlled trials evaluating wound dressings exist and do not clearly demonstrate superiority of many materials or categories. Comparative effectiveness research can be used as a tool to evaluate topical therapy for wound care moving into the future. Until further data emerge, education on the available products and logical clinical thought must prevail. PMID:25126472
Evaluation of three-layered doxycycline-collagen loaded nanofiber wound dressing.
Tort, Serdar; Acartürk, Füsun; Beşikci, Arzu
2017-08-30
Nanofiber wound dressings have great potential for both acute and chronic wound healing. The aim of this study is to develop a wound dressing by the electrospinning method and to determine its in vitro characteristics. The viscosity and the surface tension values of the polymer solutions used in the electrospinning were measured and their suitability for electrospinning was evaluated. Nanofiber wound dressing consists of three layers. The first and the second layers are sodium alginate and chitosan nanofibers, respectively. The core of the coaxial nanofibers that comprises the third layer of the wound dressing contains 1% polycaprolactone and 4.5% collagen, the shell comprises 2.5% doxycycline and 2.5% polyethylene oxide. The developed wound dressing comprises aligned nanofibers, with a contact angle of 38°, a work of bioadhesion value of 0.485mJ/cm 2 on rat skin, a tensile strength of 2.76MPa, an elongation at break value of 7.65%, a specific surface area of 9.65m 2 /g and a porosity of 52.3%. The amount of doxycycline content was found to be 260μg/cm 2 and the complete drug release was achieved in 15min. No cytotoxic effect was shown in cell culture studies with keratinocyte cell lines. As a result of the stability studies, it was found that the morphological, mechanical, bioadhesion and wettability properties and the amount of doxycycline remained stable for a period of 12 months at 4°C/ambient humidity condition. The developed three-layered wound dressing could be an alternative for wound healing applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Sulthiame-induced drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome.
Fong, Choong Yi; Hashim, Nurmaira; Gan, Chin Seng; Chow, Tak Kuan; Tay, Chee Geap
2016-11-01
Drug reaction with eosinophilia and systemic symptoms (DRESS) syndrome is a rare and potentially life-threatening acute drug-induced hypersensitivity reaction. Antiepileptic drugs (AEDs) predominantly aromatic AEDs are commonly reported in DRESS. To date there are no reports of sulthiame AED causing DRESS syndrome. We report a 10-year-old girl of Indian descent with AED resistant epilepsy on maintenance sodium valproate and clonazepam. Sulthiame AED was initiated to try to improve her seizure control. Five weeks after commencing sulthiame, she developed fever with a diffuse erythematous morbilliform maculopapular rash, elevated transaminases and atypical lymphocytes. At day 3 of illness, she deteriorated with worsening elevation of liver transaminases, thrombocytopenia, progression of rash, hepatosplenomegaly, pneumonitis and markedly elevated inflammatory markers. Immunomodulatory treatment of pulse methylprednisolone was given from day 7 which was associated with improvement inflammatory markers and complete resolution of rash from day 30 of illness. The diagnosis of sulthiame-induced DRESS syndrome was made based on clinical, laboratory and skin histology findings. She was HLA-B heterozygous for HLA-B ∗ 15:123 and 15:240 and HLA-A homozygous for HLA-A ∗ 11:01:09. Both these HLA-A and HLA-B typing has not been reported before in cutaneous drug reactions. This is the first reported case of sulthiame-induced DRESS syndrome. Our case expands the list of possible susceptible HLA alleles associated with cutaneous drug reactions. It also raises the awareness of possible DRESS syndrome among patients commenced on sulthiame who will require immediate discontinuation of sulthiame and consideration of prompt treatment of corticosteroids. Copyright © 2016 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
A systematic review of silver-releasing dressings in the management of infected chronic wounds.
Lo, Shu-Fen; Hayter, Mark; Chang, Chee-Jen; Hu, Wen-Yu; Lee, Ling-Ling
2008-08-01
This paper is a systematic review with the objective of determining the effectiveness of silver-releasing dressing in the management of infected chronic wounds. Chronic wounds exhibit increased bacterial burdens which not only result in a negative physical impact on patients, impairing their quality of life, but also increase treatment costs. Silver dressings are wound products designed to control and inhibit infection and provide a wound environment conducive to healing. However, there is limited evidence on their effectiveness in doing so. A systematic review of literature from 1950-May 2007 was conducted using the PubMed, CINAHL, Cochrane, MEDLINE, British Nursing Index, EBSCO Host, OCLC, Proquest and PsychInfo databases. The review included randomised or non-randomised control trials, published in English or non-English, of silver-releasing dressings in infected chronic wounds. Of the over 1957 potentially releasing studies examined, 14 pertinent articles involving 1285 participants were identified. Almost all the participants reported one or more statistically significant outcomes. The main points to emerge from this review of studies are that silver-releasing dressings show positive effects on infected chronic wounds. The quality of the trials was limited by the potential for bias associated with inadequate concealment, no detailed description of the outcome measurement and no reported intention-to-treat analysis. Moreover, problems existed in some studies with confounding factors. The review clearly highlights the need for well-designed, methodologically standardised outcome measurement research into the effectiveness of silver-releasing dressings. It also points to the need for a comprehensive assessment of wound bed status in further studies. This review strengthens the case for the use of silver dressings when managing infected chronic wounds. They appear more effective and are tolerated well by patients. However, their use should be accompanied by a comprehensive wound assessment.
Padula, William V
The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. Retrospective observational cohort. We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (-1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (-1.13 cases/quarter; P = .035). Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products.
2017-01-01
PURPOSE: The purpose of this study was to examine the effectiveness and value of prophylactic 5-layer foam sacral dressings to prevent hospital-acquired pressure injury rates in acute care settings. DESIGN: Retrospective observational cohort. SAMPLE AND SETTING: We reviewed records of adult patients 18 years or older who were hospitalized at least 5 days across 38 acute care hospitals of the University Health System Consortium (UHC) and had a pressure injury as identified by Patient Safety Indicator #3 (PSI-03). All facilities are located in the United States. METHODS: We collected longitudinal data pertaining to prophylactic 5-layer foam sacral dressings purchased by hospital-quarter for 38 academic medical centers between 2010 and 2015. Longitudinal data on acute care, hospital-level patient outcomes (eg, admissions and PSI-03 and pressure injury rate) were queried through the UHC clinical database/resource manager from the Johns Hopkins Medicine portal. Data on volumes of dressings purchased per UHC hospital were merged with UHC data. Mixed-effects negative binomial regression was used to test the longitudinal association of prophylactic foam sacral dressings on pressure injury rates, adjusted for hospital case-mix and Medicare payments rules. RESULTS: Significant pressure injury rate reductions in US acute care hospitals between 2010 and 2015 were associated with the adoption of prophylactic 5-layer foam sacral dressings within a prevention protocol (−1.0 cases/quarter; P = .002) and changes to Medicare payment rules in 2014 (−1.13 cases/quarter; P = .035). CONCLUSIONS: Prophylactic 5-layer foam sacral dressings are an effective component of a pressure injury prevention protocol. Hospitals adopting these technologies should expect good value for use of these products. PMID:28816929
New hemostatic agents in the combat setting.
Cox, E Darrin; Schreiber, Martin A; McManus, John; Wade, Charles E; Holcomb, John B
2009-12-01
Hemorrhage is a leading cause of potentially preventable death in both civilian and military trauma patients. Animal data have shown that hemostatic bandages reduce hemorrhage and improve survival. This article reports recent clinical observations regarding the efficacy and evolution of use of two new hemostatic bandages employed in the global war on terrorism. We performed a retrospective cohort review of soldiers treated with either the QuikClot or HemCon hemostatic bandages between April and October 2006. Hemostatic dressings were placed on wounds either in the field or at the combat support hospital (CSH). During the 6-month study period, 1691 trauma patients were admitted to the CSH. Fifty uses of hemostatic dressings in 44 patients (2.6% of admissions) were identified. Forty patients were treated with HemCon dressings, three patients with QuikClot, and one with both QuikClot and HemCon. Eighteen percent of the dressings were used in the field, predominantly on extremity wounds (7/8). In contrast, most dressings used in the CSH were for truncal wounds (26/36 patients). Hemostatic dressings were applied to extremity wounds in prehospital and hospital settings, either alone or in conjunction with tourniquets. In surviving patients (95%), the treating surgeon determined that the hemorrhage was either stopped or greatly decreased by use of hemostatic dressings. Two of the four patients treated with QuikClot had burns from exothermic reactions, while no adverse reactions were noted with HemCon. Hemostatic agents stop or decrease bleeding. Whereas HemCon appears to be safe, QuikClot may produce superficial burns. These new hemostatic agents have a place in the surgical armamentarium to assist in controlling internal hemorrhage from truncal and pelvic hemorrhage, especially during damage-control surgery.
Chopra, Karan; Gowda, Arvind U; Morrow, Chris; Holton, Luther; Singh, Devinder P
2016-04-01
Complex abdominal wall reconstruction is beset by postoperative complications. A recent meta-analysis comparing the use of closed-incision negative-pressure therapy to standard dressings found a statistically significant reduction in surgical-site infection. The use of closed-incision negative-pressure therapy is gaining acceptance in this population; however, the economic impact of this innovative dressing remains unknown. In this study, a cost-utility analysis was performed assessing closed-incision negative-pressure therapy and standard dressings following closure of abdominal incisions in high-risk patients. Cost-utility methodology involved reviewing literature related to closed-incision negative-pressure therapy in abdominal wall surgery, obtaining utility estimates to calculate quality-adjusted life-year scores for successful surgery and surgery complicated by surgical-site infection, summing costs using Medicare Current Procedural Terminology codes, and creating a decision tree illuminating the most cost-effective dressing strategy. One-way sensitivity analysis was performed to assess the robustness of the results. The aforementioned meta-analysis comparing closed-incision negative-pressure therapy to standard dressings included a subset of five studies assessing abdominal wall surgery in 829 patients (260 closed-incision negative-pressure therapy and 569 standard dressings). Decision tree analysis revealed an estimated savings of $1546.52 and a gain of 0.0024 quality-adjusted life-year with closed-incision negative-pressure therapy compared with standard dressings; therefore, closed-incision negative-pressure therapy is a dominant treatment strategy. One-way sensitivity analysis revealed that closed-incision negative-pressure therapy is a cost-effective option when the surgical-site infection rate is greater than 16.39 percent. The use of closed-incision negative-pressure therapy is cost-saving following closure of abdominal incisions in high-risk patients.
The role of allogenic keratin-derived dressing in wound healing in a mouse model.
Konop, Marek; Sulejczak, Dorota; Czuwara, Joanna; Kosson, Piotr; Misicka, Aleksandra; Lipkowski, Andrzej W; Rudnicka, Lidia
2017-01-01
Keratin is an interesting protein needed for wound healing and tissue recovery. We have recently proposed a new, simple and inexpensive method to obtain fur and hair keratin-derived biomaterials suitable for medical application. The aim of the study was to evaluate the role of the fur keratin-derived protein (FKDP) dressing in the allogenic full-thickness surgical skin wound model. The data obtained using scanning electron microscopy showed that employed processed biomaterial had higher surface porosity compared with control raw material. From the MTS test, it was found keratin biomaterial is not only toxic to the NIH/3T3 cell line (p < 0.05), but also enhances cell proliferation compared with the control. In vivo studies have shown keratin dressings are tissue biocompatible, accelerate wound closure and epithelialization to the statistically significant differences on day 5 (p < 0.05) in comparison to control wounds. Histological examination revealed, that in FKDP-treated wounds the inflammatory response contained predominantly macrophages whilst their morphological untreated variants showed mixed cell infiltrates rich in neutrophils. Predominant macrophages based response creates more favorable environment for healing. In FKDP-dressed wounds the number of microhemorrhages was also significantly decreased (p < 0.05) as compared with undressed wounds. Applied keratin dressing favors reconstruction of a more regular skin structure and assures better cosmetic effect in terms of scar formation and appearance. In conclusion, fur keratin-derived protein dressings significantly accelerated wound healing in the mouse model. Further studies are needed to determine the molecular mechanisms involved in the multilayer wound healing process and to assess the possible use of these dressings for medical purposes. © 2016 by the Wound Healing Society.
Dressed soliton in quantum dusty pair-ion plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chatterjee, Prasanta; Muniandy, S. V.; Wong, C. S.
Nonlinear propagation of a quantum ion-acoustic dressed soliton is studied in a dusty pair-ion plasma. The Korteweg-de Vries (KdV) equation is derived using reductive perturbation technique. A higher order inhomogeneous differential equation is obtained for the higher order correction. The expression for a dressed soliton is calculated using a renormalization method. The expressions for higher order correction are determined using a series solution technique developed by Chatterjee et al. [Phys. Plasmas 16, 072102 (2009)].
43. Dressing rooms and corridor in basement on west side ...
43. Dressing rooms and corridor in basement on west side of building, looking south. (July 1991) A nearly identical corridor with dressing rooms ran along the east side of the basement, and the two corridors were connected by a short hallway at the north end. The theatre seats seen in hallway in this photo are from Seattle's Orpheum Theatre which was demolished in 1967. - Fox Theater, Seventh Avenue & Olive Way, Seattle, King County, WA
Leclercq, A; Labeille, B; Perrot, J-L; Vercherin, P; Cambazard, F
2016-01-01
Leg ulcers are a common condition. There have been very few studies of combined therapy involving VAC (vacuum-assisted closure) and skin graft. We performed a randomized controlled trial of VAC therapy vs. hydrocolloid dressings over 5 days following autologous grafting on chronic leg ulcers. The primary objective was to assess the difference in success (defined as a reduction in wound area of at least 50% at 1 month) between the two dressing methods. Forty-six patients with ulcers present for over one month were included. Following a 7-day hospitalization period, follow-up was performed for 3 months on an outpatient basis. Our study does not demonstrate a statistically significant difference, with a 45.8% success rate in the VAC group vs. 40.9% in the conventional dressing group (P=0.73). In the venous ulcer group, the success rate was 57.9% for VAC vs. 40% for conventional dressings (P=0.3). The difference in favor of VAC in this group was not statistically significant, most likely due to an insufficient number of patients studied. Our study does not demonstrate superiority of VAC associated with skin graft over conventional dressings. We observed more complications with VAC (40%) than with conventional dressings (23%) (P=0.06). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Preparation of SMART wound dressings based on colloidal microgels and textile fibres
NASA Astrophysics Data System (ADS)
Cornelius, Victoria J.; Majcen, Natasa; Snowden, Martin J.; Mitchell, John C.; Voncina, Bojana
2007-01-01
Wound dressings and other types of wound healing technologies are experiencing fast-paced development and rapid growth. As the population ages, demand will continue to rise for advanced dressings used to treat chronic wounds, such as pressure ulcers, venous stasis ulcers, and diabetic ulcers. Moist wound dressings, which facilitate natural wound healing in a cost-effective manner, will be increasingly important. In commercially available hydrogel / gauze wound dressings the gel swells to adsorb wound excreta and provide an efficient non adhesive particle barrier. An alternative to hydrogels are microgels. Essentially discrete colloidal gel particles, as a result of their very high surface area to volume ratio compared to bulk gels, they have a much faster response to external stimuli such as temperature or pH. In response to either an increase or decrease in solvent quality these porous networks shrink and swell reversibly. When swollen the interstitial regions within the polymer matrix are available for further chemistry; such as the incorporation of small molecules. The reversible shrinking and swelling as a function of external stimuli provides a novel drug release system. As the environmental conditions of a wound change over its lifetime, tending to increase in pH if there is an infection combining these discrete polymeric particles with a substrate such as cotton, results in a smart wound dressing.
Sung, Kun-Yong; Lee, Sang-Yeul
2016-05-01
Neonatal extravasation injuries are often associated with peripheral parenteral nutrition. Several treatment modalities have been developed and used for managing these injuries with variable results. However, there is a lack of consensus regarding the management of neonatal extravasation injuries. The aim of this paper is to introduce a new nonoperative method for the treatment of neonatal extravasation injuries associated with parenteral nutrition. The authors made multiple punctures on the extravasated wound using a No. 11 scalpel blade tip and applying a DuoDERM Extra Thin (ConvaTec Inc, Princeton, NJ) dressing, a hydrocolloid dressing. The dressing was changed every 6 hours on the first day, and dressing changes were continued with decreasing frequency according to the amount of exudate until the wound healed. After the devitalized tissue began to demarcate and autolyse, surgical debridement was gradually performed. Twelve neonatal extravasation injuries, which occurred between November 2010 and June 2014, were evaluated. The mean follow-up duration was 10 months. The average duration of treatment for wound healing was 25 days. All wounds healed without func- tional deficits and conspicuous scars. The authors suggest their new method of using multiple punctures and a hydrocolloid dressing is an easy, effective, and minimally invasive treatment for neonatal extravasation injuries associated with peripheral parenteral nutrition, and it can be used as an alternative treatment option.
Zhao, Xin; Wu, Hao; Guo, Baolin; Dong, Ruonan; Qiu, Yusheng; Ma, Peter X
2017-04-01
Injectable self-healing hydrogel dressing with multifunctional properties including anti-infection, anti-oxidative and conductivity promoting wound healing process will be highly desired in wound healing application and its design is still a challenge. We developed a series of injectable conductive self-healed hydrogels based on quaternized chitosan-g-polyaniline (QCSP) and benzaldehyde group functionalized poly(ethylene glycol)-co-poly(glycerol sebacate) (PEGS-FA) as antibacterial, anti-oxidant and electroactive dressing for cutaneous wound healing. These hydrogels presented good self-healing, electroactivity, free radical scavenging capacity, antibacterial activity, adhesiveness, conductivity, swelling ratio, and biocompatibility. Interestingly, the hydrogel with an optimal crosslinker concentration of 1.5 wt% PEGS-FA showed excellent in vivo blood clotting capacity, and it significantly enhanced in vivo wound healing process in a full-thickness skin defect model than quaternized chitosan/PEGS-FA hydrogel and commercial dressing (Tegaderm™ film) by upregulating the gene expression of growth factors including VEGF, EGF and TGF-β and then promoting granulation tissue thickness and collagen deposition. Taken together, the antibacterial electroactive injectable hydrogel dressing prolonged the lifespan of dressing relying on self-healing ability and significantly promoted the in vivo wound healing process attributed to its multifunctional properties, meaning that they are excellent candidates for full-thickness skin wound healing. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dispersion Engineering of Bose-Einstein Condensates
NASA Astrophysics Data System (ADS)
Khamehchi, Mohammad Amin
The subject of this dissertation is engineering the dispersion relation for dilute Bose-Einstein condensates (BECs). When a BEC is immersed into suitably tailored laser fields its dispersion can be strongly modified. Prominent examples for such laser fields include optical lattice geometries and Raman dressing fields. The ability to engineer the dispersion of a BEC allows for the investigation of a range of phenomena related to quantum hydrodynamics and condensed matter. In the first context, this dissertation studies the excitation spectrum of a spin-orbit coupled (SOC) BEC. The spin-orbit coupling is generated by " dressing" the atoms with two Raman laser fields. The excitation spectrum has a Roton-like feature that can be altered by tuning the Raman laser parameters. It is demonstrated that the Roton mode can be softened, but it does not reach the ground state energy for the experimental conditions we had. Furthermore, the expansion of SOC BECs in 1D is studied by relaxing the trap allowing the BEC to expand in the SOC direction. Contrary to the findings for optical lattices, it is observed that the condensate partially occupies quasimomentum states with negative effective mass, and therefore an abrupt deceleration is observed although the mean field force is along the direction of expansion. In condensed-matter systems, a periodic lattice structure often plays an important role. In this context, an alternative to the Raman dressing scheme can be realized by coupling the s- and p- bands of a static optical lattice via a weak moving lattice. The bands can be treated as pseudo-spin states. It is shown that similar to the dispersion relation of a Raman dressed SOC, the quasimomentum of the ground state is different from zero. Coherent coupling of the SOC dispersion minima can lead to the realization of the stripe phase even though it is not the thermodynamic ground state of the system. Along the lines of studying the hydrodynamics of BECs, three novel multicomponent solitonic states are realized. It is shown that the solitons are structurally stable and the oscillation of vector dark-anti-dark solitons is studied in a weak harmonic trap.
Mitchell, Michael S; Koen, Clifford M; Darden, Stephen M
2014-01-01
As more and more individuals express themselves with tattoos and body piercings and push the envelope on what is deemed appropriate in the workplace, employers have an increased need for creation and enforcement of reasonable dress codes and appearance policies. As with any employment policy or practice, an appearance policy must be implemented and enforced without regard to an individual's race, color, gender, national origin, religion, disability, age, or other protected status. A policy governing dress and appearance based on the business needs of an employer that is applied fairly and consistently and does not have a disproportionate effect on any protected class will generally be upheld if challenged in court. By examining some of the more common legal challenges to dress codes and how courts have resolved the disputes, health care managers can avoid many potential problems. This article, the second part of a 3-part examination of dress codes and appearance policies, focuses on the issue of gender under the Civil Rights Act of 1964. Pertinent court cases that provide guidance for employers are addressed.
Franchini, D; Cavaliere, L; Valastro, C; Carnevali, F; van der Esch, A; Lai, O; Di Bello, A
2016-05-03
The loggerhead Caretta caretta is the most common sea turtle in the Mediterranean. Currently, sea turtles are considered endangered, mainly due to the impact of human activities. Among traumatic lesions, those involving the skull, if complicated by brain exposure, are often life-threatening. In these cases, death could be the outcome of direct trauma of the cerebral tissue or of secondary meningoencephalitis. This uncontrolled study aims to evaluate the use of a plant-derived dressing (1 Primary Wound Dressing®) in 3 sea turtles with severe lesions of the skull exposing the brain. Following surgical curettage, the treatment protocol involved exclusive use of the plant-derived dressing applied on the wound surface as the primary dressing, daily for the first month and then every other day until the end of treatment. The wound and peri-wound skin were covered with a simple secondary dressing without any active compound (non-woven gauze with petroleum jelly). Data presented herein show an excellent healing process in all 3 cases and no side effects due to contact of the medication with the cerebral tissue.
NASA Astrophysics Data System (ADS)
Sawitri, Sicilia
2018-03-01
The aims of the research were: (1) To know the students' achievement in Dress Making Teaching by implementing Integrated Entrepreneur Material in Vocational High School, (2) The level of increasing of students' achievement in Dress Making Teaching by integrating Entrepreneurship Material in Vocational High School. By using experimental method this research was conducted in Magelang Vocational High School and applied pre-test post-test design. The samples in this research was XI grade of Fashion Technology Study Program. Observation sheet and documentation were used in this research as instruments. Data analyzed by using descriptive analyze and gain score. The result, there were: (1) students' achievement in Dress Making Teaching was high 88.6 and (2) the increasing of students' achievement was 0.61 it was medium category. The suggestion were: Integrated Entrepreneurship material can be applied in another subject matter, such as Men Wear, Tailoring, Children Wear, and The students who want to be a good entrepreneur, have to drill their skill in making dresses, and know about excellent service to the clients, marketing and make clients satisfaction.
The role of one-shot learning in #TheDress.
Drissi Daoudi, Leila; Doerig, Adrien; Parkosadze, Khatuna; Kunchulia, Marina; Herzog, Michael H
2017-03-01
#TheDress is remarkable in two aspects. First, there is a bimodal split of the population in the perception of the dress's colors (white/gold vs. black/blue). Second, whereas interobserver variance is high, intra-observer variance is low, i.e., the percept rarely switches in a given individual. There are two plausible routes of explanations: either one-shot learning during the first presentation of the image splits observers into two different, stable populations, or the differences are caused by stable traits of observers, such as different visual systems. Here, we hid large parts of the image by white occluders. The majority of naïve participants perceived the dress as black and blue. With black occluders, the majority of observers perceived the dress as white and gold. The percept did not change when we subsequently presented the full image, arguing for a crucial role of one-shot learning. Next, we investigated whether the first fixation determines the perceived color in naïve observers. We found no such effect. It remains thus a puzzling question where the source of variability in the different percepts comes from.
Shahzad, Muhammad Naveed; Ahmed, Naheed
2013-02-01
To assess the efficacy of Aloe Vera gel compared with 1% silver sulfadiazine cream as a burn dressing for the treatment of superficial and partial thickness burns. This Interventional Comparative study was carried out at the Burn unit and Plastic surgery department, Nishtar Hospital Multan, Pakistan from July 2008 to December 2010. A total of 50 patients with superficial and partial thickness burns were divided into two equal groups randomly by consecutive sampling method, one group was dressed with Aloe Vera gel while the other was treated with 1% silversulphadiazine cream, and the results regarding duration of wound epithelialization, pain relief and cost of treatment were compared. In patients treated with Aloe Vera gel, healing of burn wounds were remarkably early than those patients treated with 1% silver sulfadiazine. All the patients of Aloe Vera group were relieved of pain earlier than those patients who were treated with SSD. Thermal burns patients dressed with Aloe Vera gel showed advantage compared to those dressed with SSD regarding early wound epithelialization, earlier pain relief and cost-effectiveness.
Honey in wound care: effects, clinical application and patient benefit.
Lay-flurrie, Karen
The use of honey in wound management has enjoyed a resurgence. This is largely due to the growing clinical problem of antibiotic-resistant bacteria and the combined difficulties for the practitioner in managing chronic wound types, such as burns, leg ulcers or surgical wounds, that may become infected, for example, with methicillin-resistant Staphylococcus aureus or Pseudomonas. The associated costs of treating such wounds are escalating as a result. While the use of honey as a wound dressing has been recognized, at least since Egyptian times circa 2000 BC, it is only more recently, due to the development and licensing of modern honey wound dressings, that such dressings have become more widely available and used in wound management. This article focuses on the use of honey in the treatment of infected wounds and burns. It will examine the effects of honey at the wound bed and its clinical applications, along with the current dressings available. Also discussed are the practical considerations, if, like any wound dressing, honey is to be used safely, appropriately and for the benefit of the patient.
Dupouey, Julien; Wiramus, Sandrine; Albanese, Jacques; Guilhaumou, Romain; Blin, Olivier
2016-10-01
Severe burned patients present high risk of skins infections, frequently due to Pseudomonas aeruginosa. Impregnated dressings with amikacin or colistin could be a good alternative to obtain effective concentration directly at the infected site. Therapeutic drug monitoring for these antibiotics is currently recommended after an intravenous administration to obtain effective and non-toxic plasmatic concentrations. However, data are lacking about systemic exposition and risk of toxicity after an administration with impregnated dressings. We report the case of a severe burned patient with cutaneous infection treated with amikacin and colistin impregnated dressings, for which plasmatic pharmacokinetic profiles were performed. Copyright © 2016 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.
Febuxostat hypersensitivity: another cause of DRESS syndrome in chronic kidney disease?
Paschou, E; Gavriilaki, E; Papaioannou, G; Tsompanakou, A; Kalaitzoglou, A; Sabanis, N
2016-11-01
Febuxostat is a xanthine oxidase inhibitor that during the last years has successfully replaced allopurinol treatment in patients with chronic kidney disease (CKD) and hyperuricemia. Several adverse events have been observed during therapy with febuxostat. DRESS (Drug Reaction with Eosinophilia and Systemic Symptoms) syndrome induced by febuxostat has been poorly described, mainly in patient with CKD who previously developed allopurinol hypersensitivity syndrome. DRESS syndrome is characterized by manifold cutaneous reactions and systemic disorders with potential devastating consequences. The underlying pathogenetic mechanisms remain unidentified, though immune responses are often complicated. P-i concept can partially explain the phenomenon. The role of renal insufficiency appears to be crucial and further investigation is required. The present article describes the case of a CKD patient that developed febuxostat-related DRESS syndrome.
Recent advances on antimicrobial wound dressing: A review.
Simões, Déborah; Miguel, Sónia P; Ribeiro, Maximiano P; Coutinho, Paula; Mendonça, António G; Correia, Ilídio J
2018-06-01
Skin and soft tissue infections (SSTIs) have high rates of morbidity and mortality associated. Despite the successful treatment of some SSTIs, those affecting the subcutaneous tissue, fascia, or muscle delay the healing process and can lead to life-threatening conditions. Therefore, more effective treatments are required to deal with such pathological situations. Recently, wound dressings loaded with antimicrobial agents emerged as viable options to reduce wound bacterial colonization and infection, in order to improve the healing process. In this review, an overview of the most prominent antibacterial agents incorporated in wound dressings along with their mode of action is provided. Furthermore, the recent advances in the therapeutic approaches used in the clinic and some future perspectives regarding antibacterial wound dressings are also discussed. Copyright © 2018 Elsevier B.V. All rights reserved.
Jacobson, Caroline; Williams, Andrew; Yang, Rongchang; Ryan, Una; Carmichael, Ian; Campbell, Angus J; Gardner, Graham E
2016-09-15
Associations between intensity and frequency of Cryptosporidium and Giardia shedding with growth, carcase weight and dressing% were investigated using a longitudinal study of 1182 lambs on eight Australian farms. Live weight was recorded and faecal samples were collected on three sampling occasions; weaning (approximately 12 weeks of age), post-weaning (approximately 19 weeks) and pre-slaughter (approximately 29 weeks). Hot standard carcase weight (HSCW) and dressing% were measured at slaughter. Faecal samples were screened for presence and concentration of Cryptosporidium, Giardia and Haemonchus oocysts using a quantitative PCR. Trichostrongylid eggs were quantified with modified McMaster faecal worm egg count (WEC). Protozoan shedding intensity was categorised as high (above median oocyst concentration in positive sheep), low (below median oocyst concentration in positive sheep) or not detected. Shedding was also categorised for shedding type (no shedding, single Giardia infection, single Cryptosporidium infection, concurrent Giardia and Cryptosporidium infection) and lambs were categorised for frequency of shedding (shedding identified on 0, 1, 2 or 3 occasions). Associations of parasite shedding intensity category, shedding type, shedding frequency, WEC and Haemonchus status (positive or negative) with lamb production were assessed using general linear models (HSCW and dressing%) and linear mixed effects models (live weight). High Cryptosporidium parvum shedding was associated with lower live weight, ranging 2.31-4.52kg over the 3 sampling occasions. Cryptosporidium parvum shedding was associated with less HSCW in high (3.22kg less) and low (3.22kg less) shedding lambs post-weaning, and high (2.21kg less) and low (2.60kg less) shedding lambs pre-slaughter as well as lower dressing% (2.7% lower in high shedding lambs post-weaning). Cryptosporidium (all species) shedding pre-slaughter was associated with reduced dressing% in both high (1.25% lower) and low (1.21% lower) shedding lambs. Giardia shedding pre-slaughter was associated with 0.59kg less HSCW in high shedding lambs. Increased frequency of C. parvum and Giardia shedding in a specific animal (repeated detection) were associated with reduced HSCW and dressing%. Concurrent Giardia and Cryptosporidium shedding pre-slaughter was associated with reduced dressing%. No statistically significant main effects for either WEC (P>0.05) or Haemonchus status (P>0.05) were identified for any of the sheep meat productivity measures (live weight, HSCW and dressing%). The findings suggest naturally acquired Cryptosporidium and Giardia infections in grazing sheep are associated with depressed growth, carcase weight and dressing efficiency beyond the neonatal period in sheep representing a range of genetic backgrounds and different sheep production environments. Copyright © 2016 Elsevier B.V. All rights reserved.
Tenti, Lorenzo; Maynau, Daniel; Angeli, Celestino; Calzado, Carmen J
2016-07-21
A new strategy based on orthogonal valence-bond analysis of the wave function combined with intermediate Hamiltonian theory has been applied to the evaluation of the magnetic coupling constants in two AF systems. This approach provides both a quantitative estimate of the J value and a detailed analysis of the main physical mechanisms controlling the coupling, using a combined perturbative + variational scheme. The procedure requires a selection of the dominant excitations to be treated variationally. Two methods have been employed: a brute-force selection, using a logic similar to that of the CIPSI approach, or entanglement measures, which identify the most interacting orbitals in the system. Once a reduced set of excitations (about 300 determinants) is established, the interaction matrix is dressed at the second-order of perturbation by the remaining excitations of the CI space. The diagonalization of the dressed matrix provides J values in good agreement with experimental ones, at a very low-cost. This approach demonstrates the key role of d → d* excitations in the quantitative description of the magnetic coupling, as well as the importance of using an extended active space, including the bridging ligand orbitals, for the binuclear model of the intermediates of multicopper oxidases. The method is a promising tool for dealing with complex systems containing several active centers, as an alternative to both pure variational and DFT approaches.
Retrenchment: General Russell E. Dougherty and the Strategic Air Command During the Age of Detente
2014-06-01
could reschedule for the next day. Dougherty noted he was unable to stay in Washington for an 38...their aid. The wife turned out to be a nurse and she tore strips from the dress she was wearing to stop Dougherty’s bleeding. Weir landed in a...bought a new dress and mailed it to the nurse who ruined her own dress in her efforts to aid him and his friend.94 Dougherty still had one arm in a
Painful dressing changes for chronic wounds: assessment and management.
Solowiej, Kazia; Upton, Dominic
Wound pain can arise from the wound itself, continuing wound treatment and anticipatory pain, which occurs in some patients as a consequence of negative experiences of care. Specifically, pain caused by the removal and application of dressings has been identified as a major contributor to wound pain, from both patient and health professional perspectives. This article reviews literature on the impact of pain at dressing change, and provides practical suggestions for assessment and management of pain during wound care.
Irreversible Processes in Ionized Gases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balescu, R.
1960-01-01
The general theory of irreversible processes, developed by Prigogine and Balescu, is applied to the case of long range interactions in ionized gases. A similar diagram technique permits the systematic selection of all the contributions to the evolution of the distribution function, a an order of approximation equivalent to Debye's equilibrium theory. The infinite series which appear in this way can be summed exactly. The resulting evolution equations have a clear physical significance: they describe interactions of "quasi particles," which are electrons or ions "dressed" by their polarization clouds. These clouds are not a permanent feature, as in equilibrium theory,more » but have a nonequilibrium, changing shape, distorted by the motions of the particles. From the mathematical point of view, these equations exhibit a new type of nonlinearity, which is very directly related to the collective nature of the interactions.« less
Rydberg interaction induced enhanced excitation in thermal atomic vapor.
Kara, Dushmanta; Bhowmick, Arup; Mohapatra, Ashok K
2018-03-27
We present the experimental demonstration of interaction induced enhancement in Rydberg excitation or Rydberg anti-blockade in thermal atomic vapor. We have used optical heterodyne detection technique to measure Rydberg population due to two-photon excitation to the Rydberg state. The anti-blockade peak which doesn't satisfy the two-photon resonant condition is observed along with the usual two-photon resonant peak which can't be explained using the model with non-interacting three-level atomic system. A model involving two interacting atoms is formulated for thermal atomic vapor using the dressed states of three-level atomic system to explain the experimental observations. A non-linear dependence of vapor density is observed for the anti-blockade peak which also increases with increase in principal quantum number of the Rydberg state. A good agreement is found between the experimental observations and the proposed interacting model. Our result implies possible applications towards quantum logic gates using Rydberg anti-blockade in thermal atomic vapor.
9. View to west of Tropic Dressing Room (typical). ...
9. View to west of Tropic Dressing Room (typical). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA
Silver-containing foam dressings with Safetac: a review of the scientific and clinical data.
Davies, Phil; McCarty, Sara; Hamberg, Kristina
2017-06-01
Background Topical antimicrobials, such as silver dressings, are progressively being used alongside systemic antibiotics to provide adjunctive, antimicrobial therapy to wounds that are clinically infected or at risk of infection. To help improve wound management, dressings that use Safetac soft silicone technology in combination with a silver-impregnated foam dressing material were developed by Mölnlycke Health Care (Gothenburg, Sweden). The range comprises Mepilex Ag, Mepilex Border Ag and Mepilex Transfer Ag. Aims A literature review was undertaken to identify and summarise clinical data from the entire evidence hierarchy, as well as data from in vitro tests, which support the use of silver-containing foam dressings with Safetac. Method The MEDLINE (National Library of Medicine, Bethesda, US) and EMBASE (Elsevier BV, Amsterdam, Netherlands) bibliographic databases were searched. In addition, abstract books and proceedings documents relating to national and international conferences were scanned in order to identify presentations (oral, e-poster and poster) of relevance to the review. Results In vitro test results showed that the silver-containing foam dressings with Safetac have both rapid and sustained activity against a range of wound pathogens, reducing planktonic and established biofilm cultures, and preventing biofilm formation. In numerous clinical studies, silvercontaining foam dressings with Safetac were used to manage wound bioburden effectively and resolve signs of localised infection in both acute wounds (such as surgical, traumatic and burn injuries) and chronic wounds (such as leg ulcers, pressure ulcers (PUs), diabetic foot ulcers (DFUs), and cancerous wounds). Studies reported that silver-containing foam dressings with Safetac are easy to use, provide an optimal environment for wound healing, and are associated with atraumatic and virtually painfree removal. As well as being clinically effective, they are reported to be cost-effective when used on wounds that require topical antimicrobial therapy. Conclusion The findings of both scientific and clinical studies clearly indicate that clinical, patient-related and economic benefits are associated with the use of Mepilex Ag, Mepilex Border Ag and Mepilex Transfer Ag with Safetac in the treatment of wounds where antimicrobial activity is needed to help manage bioburden.
Pregnancy Complications: Salmonellosis
... including homemade mayonnaise, hollandaise sauce, Caesar salad dressing, cookie dough, frostings and homemade ice cream. Unpasteurized milk, milk ... including homemade mayonnaise, hollandaise sauce, Caesar salad dressing, cookie dough, frostings and homemade ice cream. Unpasteurized milk, milk ...
Satake, Toshihiko; Muto, Mayu; Nagashima, Yu; Haga, Shoko; Homma, Yuki; Nakasone, Reiko; Kadokura, Marina; Kou, Seiko; Fujimoto, Hiroshi; Maegawa, Jiro
2018-04-01
We describe a new wound management technique using a soft dressing material to stabilize the areola skin graft and protect the nipple after nipple-areola reconstruction at the final stage of breast reconstruction. We introduced a center-fenestrated multilayered hydrocellular polyurethane foam dressing material that provides adequate pressure and retains a moist environment for a smooth skin graft "take." Moreover, the reconstructed nipple can be monitored at any time through the fenestrated window for adequate blood circulation. Altogether, this simple and inexpensive wound dressing technique improves the clinical outcome. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .