NASA Technical Reports Server (NTRS)
Malone, T. B.; Micocci, A.
1975-01-01
The alternate methods of conducting a man-machine interface evaluation are classified as static and dynamic, and are evaluated. A dynamic evaluation tool is presented to provide for a determination of the effectiveness of the man-machine interface in terms of the sequence of operations (task and task sequences) and in terms of the physical characteristics of the interface. This dynamic checklist approach is recommended for shuttle and shuttle payload man-machine interface evaluations based on reduced preparation time, reduced data, and increased sensitivity of critical problems.
Quantitative method of medication system interface evaluation.
Pingenot, Alleene Anne; Shanteau, James; Pingenot, James D F
2007-01-01
The objective of this study was to develop a quantitative method of evaluating the user interface for medication system software. A detailed task analysis provided a description of user goals and essential activity. A structural fault analysis was used to develop a detailed description of the system interface. Nurses experienced with use of the system under evaluation provided estimates of failure rates for each point in this simplified fault tree. Means of estimated failure rates provided quantitative data for fault analysis. Authors note that, although failures of steps in the program were frequent, participants reported numerous methods of working around these failures so that overall system failure was rare. However, frequent process failure can affect the time required for processing medications, making a system inefficient. This method of interface analysis, called Software Efficiency Evaluation and Fault Identification Method, provides quantitative information with which prototypes can be compared and problems within an interface identified.
Noncontact evaluation for interface states by photocarrier counting
NASA Astrophysics Data System (ADS)
Furuta, Masaaki; Shimizu, Kojiro; Maeta, Takahiro; Miyashita, Moriya; Izunome, Koji; Kubota, Hiroshi
2018-03-01
We have developed a noncontact measurement method that enables in-line measurement and does not have any test element group (TEG) formation. In this method, the number of photocarriers excited from the interface states are counted which is called “photocarrier counting”, and then the energy distribution of the interface states density (D it) is evaluated by spectral light excitation. In our previous experiment, the method used was a preliminary contact measurement method at the oxide on top of the Si wafer. We developed, at this time, a D it measurement method as a noncontact measurement with a gap between the probes and the wafer. The shallow trench isolation (STI) sidewall has more localized interface states than the region under the gate electrode. We demonstrate the noncontact measurement of trapped carriers from interface states using wafers of three different crystal plane orientations. The demonstration will pave the way for evaluating STI sidewall interface states in future studies.
Importance of curvature evaluation scale for predictive simulations of dynamic gas-liquid interfaces
NASA Astrophysics Data System (ADS)
Owkes, Mark; Cauble, Eric; Senecal, Jacob; Currie, Robert A.
2018-07-01
The effect of the scale used to compute the interfacial curvature on the prediction of dynamic gas-liquid interfaces is investigated. A new interface curvature calculation methodology referred to herein as the Adjustable Curvature Evaluation Scale (ACES) is proposed. ACES leverages a weighted least squares regression to fit a polynomial through points computed on the volume-of-fluid representation of the gas-liquid interface. The interface curvature is evaluated from this polynomial. Varying the least squares weight with distance from the location where the curvature is being computed, adjusts the scale the curvature is evaluated on. ACES is verified using canonical static test cases and compared against second- and fourth-order height function methods. Simulations of dynamic interfaces, including a standing wave and oscillating droplet, are performed to assess the impact of the curvature evaluation scale for predicting interface motions. ACES and the height function methods are combined with two different unsplit geometric volume-of-fluid (VoF) schemes that define the interface on meshes with different levels of refinement. We find that the results depend significantly on curvature evaluation scale. Particularly, the ACES scheme with a properly chosen weight function is accurate, but fails when the scale is too small or large. Surprisingly, the second-order height function method is more accurate than the fourth-order variant for the dynamic tests even though the fourth-order method performs better for static interfaces. Comparing the curvature evaluation scale of the second- and fourth-order height function methods, we find the second-order method is closer to the optimum scale identified with ACES. This result suggests that the curvature scale is driving the accuracy of the dynamics. This work highlights the importance of studying numerical methods with realistic (dynamic) test cases and that the interactions of the various discretizations is as important as the accuracy of one part of the discretization.
Blind predictions of protein interfaces by docking calculations in CAPRI.
Lensink, Marc F; Wodak, Shoshana J
2010-11-15
Reliable prediction of the amino acid residues involved in protein-protein interfaces can provide valuable insight into protein function, and inform mutagenesis studies, and drug design applications. A fast-growing number of methods are being proposed for predicting protein interfaces, using structural information, energetic criteria, or sequence conservation or by integrating multiple criteria and approaches. Overall however, their performance remains limited, especially when applied to nonobligate protein complexes, where the individual components are also stable on their own. Here, we evaluate interface predictions derived from protein-protein docking calculations. To this end we measure the overlap between the interfaces in models of protein complexes submitted by 76 participants in CAPRI (Critical Assessment of Predicted Interactions) and those of 46 observed interfaces in 20 CAPRI targets corresponding to nonobligate complexes. Our evaluation considers multiple models for each target interface, submitted by different participants, using a variety of docking methods. Although this results in a substantial variability in the prediction performance across participants and targets, clear trends emerge. Docking methods that perform best in our evaluation predict interfaces with average recall and precision levels of about 60%, for a small majority (60%) of the analyzed interfaces. These levels are significantly higher than those obtained for nonobligate complexes by most extant interface prediction methods. We find furthermore that a sizable fraction (24%) of the interfaces in models ranked as incorrect in the CAPRI assessment are actually correctly predicted (recall and precision ≥50%), and that these models contribute to 70% of the correct docking-based interface predictions overall. Our analysis proves that docking methods are much more successful in identifying interfaces than in predicting complexes, and suggests that these methods have an excellent potential of addressing the interface prediction challenge. © 2010 Wiley-Liss, Inc.
Intelligent interface design and evaluation
NASA Technical Reports Server (NTRS)
Greitzer, Frank L.
1988-01-01
Intelligent interface concepts and systematic approaches to assessing their functionality are discussed. Four general features of intelligent interfaces are described: interaction efficiency, subtask automation, context sensitivity, and use of an appropriate design metaphor. Three evaluation methods are discussed: Functional Analysis, Part-Task Evaluation, and Operational Testing. Design and evaluation concepts are illustrated with examples from a prototype expert system interface for environmental control and life support systems for manned space platforms.
Comfort evaluation of a subject-specific seating interface formed by vibrating grains.
Liu, Shenghui; Qu, Yunxia; Hou, Shujun; Li, Kai; Li, Xinye; Zhai, Yang; Ji, Yunxiao
2018-09-01
Sitting is the most common posture for work in offices, and spinal cord injury (SCI) patients who are wheelchair dependent spend 10.6 h per day seated in wheelchairs. Thus, the comfort of subject-specific interfaces is increasingly important for the well-being of patients and office workers. This paper introduces a new method of forming a subject-specific interface, based on vibrating grains. Twenty subjects (10 females and 10 males) participated in the sitting test. Interface comfort was evaluated using the pressure distribution and subjective rating methods. Five seating interface types were compared. The results showed that compared with a flat interface, the interfaces formed by vibrating grains had a significantly reduced peak contact pressure (PeakCP) (by more than 58.03%), and that PeakCP was highly correlated with the comfort rating (R = -0.533) and discomfort rating(R = -0.603). This new method shows promise for guiding the future development of customized seating interfaces. Copyright © 2018 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... of Gaseous Organic Compounds by Direct Interface Gas Chromatography-Mass Spectrometry (incorporated... Method for Determination of Gaseous Organic Compounds by Direct Interface Gas Chromatography-Mass... Interface Gas Chromatography-Mass Spectrometry (incorporated by reference, see § 63.14),; or (B) For target...
Usability Evaluation Methods for Gesture-Based Games: A Systematic Review
Simor, Fernando Winckler; Brum, Manoela Rogofski; Schmidt, Jaison Dairon Ebertz; De Marchi, Ana Carolina Bertoletti
2016-01-01
Background Gestural interaction systems are increasingly being used, mainly in games, expanding the idea of entertainment and providing experiences with the purpose of promoting better physical and/or mental health. Therefore, it is necessary to establish mechanisms for evaluating the usability of these interfaces, which make gestures the basis of interaction, to achieve a balance between functionality and ease of use. Objective This study aims to present the results of a systematic review focused on usability evaluation methods for gesture-based games, considering devices with motion-sensing capability. We considered the usability methods used, the common interface issues, and the strategies adopted to build good gesture-based games. Methods The research was centered on four electronic databases: IEEE, Association for Computing Machinery (ACM), Springer, and Science Direct from September 4 to 21, 2015. Within 1427 studies evaluated, 10 matched the eligibility criteria. As a requirement, we considered studies about gesture-based games, Kinect and/or Wii as devices, and the use of a usability method to evaluate the user interface. Results In the 10 studies found, there was no standardization in the methods because they considered diverse analysis variables. Heterogeneously, authors used different instruments to evaluate gesture-based interfaces and no default approach was proposed. Questionnaires were the most used instruments (70%, 7/10), followed by interviews (30%, 3/10), and observation and video recording (20%, 2/10). Moreover, 60% (6/10) of the studies used gesture-based serious games to evaluate the performance of elderly participants in rehabilitation tasks. This highlights the need for creating an evaluation protocol for older adults to provide a user-friendly interface according to the user’s age and limitations. Conclusions Through this study, we conclude this field is in need of a usability evaluation method for serious games, especially games for older adults, and that the definition of a methodology and a test protocol may offer the user more comfort, welfare, and confidence. PMID:27702737
Waterflooding injectate design systems and methods
Brady, Patrick V.; Krumhansl, James L.
2014-08-19
A method of designing an injectate to be used in a waterflooding operation is disclosed. One aspect includes specifying data representative of chemical characteristics of a liquid hydrocarbon, a connate, and a reservoir rock, of a subterranean reservoir. Charged species at an interface of the liquid hydrocarbon are determined based on the specified data by evaluating at least one chemical reaction. Charged species at an interface of the reservoir rock are determined based on the specified data by evaluating at least one chemical reaction. An extent of surface complexation between the charged species at the interfaces of the liquid hydrocarbon and the reservoir rock is determined by evaluating at least one surface complexation reaction. The injectate is designed and is operable to decrease the extent of surface complexation between the charged species at interfaces of the liquid hydrocarbon and the reservoir rock. Other methods, apparatus, and systems are disclosed.
Usability Evaluation Methods for Gesture-Based Games: A Systematic Review.
Simor, Fernando Winckler; Brum, Manoela Rogofski; Schmidt, Jaison Dairon Ebertz; Rieder, Rafael; De Marchi, Ana Carolina Bertoletti
2016-10-04
Gestural interaction systems are increasingly being used, mainly in games, expanding the idea of entertainment and providing experiences with the purpose of promoting better physical and/or mental health. Therefore, it is necessary to establish mechanisms for evaluating the usability of these interfaces, which make gestures the basis of interaction, to achieve a balance between functionality and ease of use. This study aims to present the results of a systematic review focused on usability evaluation methods for gesture-based games, considering devices with motion-sensing capability. We considered the usability methods used, the common interface issues, and the strategies adopted to build good gesture-based games. The research was centered on four electronic databases: IEEE, Association for Computing Machinery (ACM), Springer, and Science Direct from September 4 to 21, 2015. Within 1427 studies evaluated, 10 matched the eligibility criteria. As a requirement, we considered studies about gesture-based games, Kinect and/or Wii as devices, and the use of a usability method to evaluate the user interface. In the 10 studies found, there was no standardization in the methods because they considered diverse analysis variables. Heterogeneously, authors used different instruments to evaluate gesture-based interfaces and no default approach was proposed. Questionnaires were the most used instruments (70%, 7/10), followed by interviews (30%, 3/10), and observation and video recording (20%, 2/10). Moreover, 60% (6/10) of the studies used gesture-based serious games to evaluate the performance of elderly participants in rehabilitation tasks. This highlights the need for creating an evaluation protocol for older adults to provide a user-friendly interface according to the user's age and limitations. Through this study, we conclude this field is in need of a usability evaluation method for serious games, especially games for older adults, and that the definition of a methodology and a test protocol may offer the user more comfort, welfare, and confidence.
A novel asynchronous access method with binary interfaces
2008-01-01
Background Traditionally synchronous access strategies require users to comply with one or more time constraints in order to communicate intent with a binary human-machine interface (e.g., mechanical, gestural or neural switches). Asynchronous access methods are preferable, but have not been used with binary interfaces in the control of devices that require more than two commands to be successfully operated. Methods We present the mathematical development and evaluation of a novel asynchronous access method that may be used to translate sporadic activations of binary interfaces into distinct outcomes for the control of devices requiring an arbitrary number of commands to be controlled. With this method, users are required to activate their interfaces only when the device under control behaves erroneously. Then, a recursive algorithm, incorporating contextual assumptions relevant to all possible outcomes, is used to obtain an informed estimate of user intention. We evaluate this method by simulating a control task requiring a series of target commands to be tracked by a model user. Results When compared to a random selection, the proposed asynchronous access method offers a significant reduction in the number of interface activations required from the user. Conclusion This novel access method offers a variety of advantages over traditionally synchronous access strategies and may be adapted to a wide variety of contexts, with primary relevance to applications involving direct object manipulation. PMID:18959797
Interfacial Micromechanics in Fibrous Composites: Design, Evaluation, and Models
Lei, Zhenkun; Li, Xuan; Qin, Fuyong; Qiu, Wei
2014-01-01
Recent advances of interfacial micromechanics in fiber reinforced composites using micro-Raman spectroscopy are given. The faced mechanical problems for interface design in fibrous composites are elaborated from three optimization ways: material, interface, and computation. Some reasons are depicted that the interfacial evaluation methods are difficult to guarantee the integrity, repeatability, and consistency. Micro-Raman study on the fiber interface failure behavior and the main interface mechanical problems in fibrous composites are summarized, including interfacial stress transfer, strength criterion of interface debonding and failure, fiber bridging, frictional slip, slip transition, and friction reloading. The theoretical models of above interface mechanical problems are given. PMID:24977189
NASA Astrophysics Data System (ADS)
Sun, Huafei; Darmofal, David L.
2014-12-01
In this paper we propose a new high-order solution framework for interface problems on non-interface-conforming meshes. The framework consists of a discontinuous Galerkin (DG) discretization, a simplex cut-cell technique, and an output-based adaptive scheme. We first present a DG discretization with a dual-consistent output evaluation for elliptic interface problems on interface-conforming meshes, and then extend the method to handle multi-physics interface problems, in particular conjugate heat transfer (CHT) problems. The method is then applied to non-interface-conforming meshes using a cut-cell technique, where the interface definition is completely separate from the mesh generation process. No assumption is made on the interface shape (other than Lipschitz continuity). We then equip our strategy with an output-based adaptive scheme for an accurate output prediction. Through numerical examples, we demonstrate high-order convergence for elliptic interface problems and CHT problems with both smooth and non-smooth interface shapes.
On the Ionization and Ion Transmission Efficiencies of Different ESI-MS Interfaces
Cox, Jonathan T.; Marginean, Ioan; Smith, Richard D.; Tang, Keqi
2014-01-01
The achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. These performance characteristics are difficult to evaluate and compare across multiple platforms as it is difficult to correlate electrical current measurements to actual analyte ions reaching the detector of a mass spectrometer. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuring the total gas phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Using this method we systematically studied the ion transmission and ionization efficiencies of different ESI-MS interface configurations, including a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interface with a single emitter and an emitter array, respectively. Our experimental results indicate that the overall ion utilization efficiency of SPIN-MS interface configurations exceeds that of the inlet capillary-based ESI-MS interface configurations. PMID:25267087
On the ionization and ion transmission efficiencies of different ESI-MS interfaces.
Cox, Jonathan T; Marginean, Ioan; Smith, Richard D; Tang, Keqi
2015-01-01
The achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. These performance characteristics are difficult to evaluate and compare across multiple platforms as it is difficult to correlate electrical current measurements to actual analyte ions reaching the detector of a mass spectrometer. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuring the total gas-phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Using this method, we systematically studied the ion transmission and ionization efficiencies of different ESI-MS interface configurations, including a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interface with a single emitter and an emitter array, respectively. Our experimental results indicate that the overall ion utilization efficiency of SPIN-MS interface configurations exceeds that of the inlet capillary-based ESI-MS interface configurations.
NASA Astrophysics Data System (ADS)
Holzinger, Andreas; Stickel, Christian; Fassold, Markus; Ebner, Martin
Interface consistency is an important basic concept in web design and has an effect on performance and satisfaction of end users. Consistency also has significant effects on the learning performance of both expert and novice end users. Consequently, the evaluation of consistency within a e-learning system and the ensuing eradication of irritating discrepancies in the user interface redesign is a big issue. In this paper, we report of our experiences with the Shadow Expert Technique (SET) during the evaluation of the consistency of the user interface of a large university learning management system. The main objective of this new usability evaluation method is to understand the interaction processes of end users with a specific system interface. Two teams of usability experts worked independently from each other in order to maximize the objectivity of the results. The outcome of this SET method is a list of recommended changes to improve the user interaction processes, hence to facilitate high consistency.
Multi-modal virtual environment research at Armstrong Laboratory
NASA Technical Reports Server (NTRS)
Eggleston, Robert G.
1995-01-01
One mission of the Paul M. Fitts Human Engineering Division of Armstrong Laboratory is to improve the user interface for complex systems through user-centered exploratory development and research activities. In support of this goal, many current projects attempt to advance and exploit user-interface concepts made possible by virtual reality (VR) technologies. Virtual environments may be used as a general purpose interface medium, an alternative display/control method, a data visualization and analysis tool, or a graphically based performance assessment tool. An overview is given of research projects within the division on prototype interface hardware/software development, integrated interface concept development, interface design and evaluation tool development, and user and mission performance evaluation tool development.
NASA Technical Reports Server (NTRS)
Bement, Laurence J.; Schimmel, Morry L.
1989-01-01
To overcome serious weaknesses in determining the performance of initiating devices, a novel 'ignitability test method', representing actual design interfaces and ignition materials, has been developed. Ignition device output consists of heat, light, gas an burning particles. Past research methods have evaluated these parameters individually. This paper describes the development and demonstration of an ignitability test method combining all these parameters, and the quantitative assessment of the ignition performance of two widely used percussion primers, the M42C1-PA101 and the M42C2-793. The ignition materials used for this evaluation were several powder, granule and pellet sizes of black powder and boron-potassium nitrate. This test method should be useful for performance evaluation of all initiator types, quality assurance, evaluation of ignition interfaces, and service life studies of initiators and ignition materials.
Circling motion and screen edges as an alternative input method for on-screen target manipulation.
Ka, Hyun W; Simpson, Richard C
2017-04-01
To investigate a new alternative interaction method, called circling interface, for manipulating on-screen objects. To specify a target, the user makes a circling motion around the target. To specify a desired pointing command with the circling interface, each edge of the screen is used. The user selects a command before circling the target. To evaluate the circling interface, we conducted an experiment with 16 participants, comparing the performance on pointing tasks with different combinations of selection method (circling interface, physical mouse and dwelling interface) and input device (normal computer mouse, head pointer and joystick mouse emulator). A circling interface is compatible with many types of pointing devices, not requiring physical activation of mouse buttons, and is more efficient than dwell-clicking. Across all common pointing operations, the circling interface had a tendency to produce faster performance with a head-mounted mouse emulator than with a joystick mouse. The performance accuracy of the circling interface outperformed the dwelling interface. It was demonstrated that the circling interface has the potential as another alternative pointing method for selecting and manipulating objects in a graphical user interface. Implications for Rehabilitation A circling interface will improve clinical practice by providing an alternative pointing method that does not require physically activating mouse buttons and is more efficient than dwell-clicking. The Circling interface can also work with AAC devices.
Systematically evaluating interfaces for RNA-seq analysis from a life scientist perspective.
Poplawski, Alicia; Marini, Federico; Hess, Moritz; Zeller, Tanja; Mazur, Johanna; Binder, Harald
2016-03-01
RNA-sequencing (RNA-seq) has become an established way for measuring gene expression in model organisms and humans. While methods development for refining the corresponding data processing and analysis pipeline is ongoing, protocols for typical steps have been proposed and are widely used. Several user interfaces have been developed for making such analysis steps accessible to life scientists without extensive knowledge of command line tools. We performed a systematic search and evaluation of such interfaces to investigate to what extent these can indeed facilitate RNA-seq data analysis. We found a total of 29 open source interfaces, and six of the more widely used interfaces were evaluated in detail. Central criteria for evaluation were ease of configuration, documentation, usability, computational demand and reporting. No interface scored best in all of these criteria, indicating that the final choice will depend on the specific perspective of users and the corresponding weighting of criteria. Considerable technical hurdles had to be overcome in our evaluation. For many users, this will diminish potential benefits compared with command line tools, leaving room for future improvement of interfaces. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Rojas, Mario; Ponce, Pedro; Molina, Arturo
2016-08-01
This paper presents the evaluation, under standardized metrics, of alternative input methods to steer and maneuver a semi-autonomous electric wheelchair. The Human-Machine Interface (HMI), which includes a virtual joystick, head movements and speech recognition controls, was designed to facilitate mobility skills for severely disabled people. Thirteen tasks, which are common to all the wheelchair users, were attempted five times by controlling it with the virtual joystick and the hands-free interfaces in different areas for disabled and non-disabled people. Even though the prototype has an intelligent navigation control, based on fuzzy logic and ultrasonic sensors, the evaluation was done without assistance. The scored values showed that both controls, the head movements and the virtual joystick have similar capabilities, 92.3% and 100%, respectively. However, the 54.6% capacity score obtained for the speech control interface indicates the needs of the navigation assistance to accomplish some of the goals. Furthermore, the evaluation time indicates those skills which require more user's training with the interface and specifications to improve the total performance of the wheelchair.
Protein-Protein Interface Predictions by Data-Driven Methods: A Review
Xue, Li C; Dobbs, Drena; Bonvin, Alexandre M.J.J.; Honavar, Vasant
2015-01-01
Reliably pinpointing which specific amino acid residues form the interface(s) between a protein and its binding partner(s) is critical for understanding the structural and physicochemical determinants of protein recognition and binding affinity, and has wide applications in modeling and validating protein interactions predicted by high-throughput methods, in engineering proteins, and in prioritizing drug targets. Here, we review the basic concepts, principles and recent advances in computational approaches to the analysis and prediction of protein-protein interfaces. We point out caveats for objectively evaluating interface predictors, and discuss various applications of data-driven interface predictors for improving energy model-driven protein-protein docking. Finally, we stress the importance of exploiting binding partner information in reliably predicting interfaces and highlight recent advances in this emerging direction. PMID:26460190
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fujiwara, K., E-mail: ku.fujiwara@screen.co.jp; Department of Mechanical Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871; Shibahara, M., E-mail: siba@mech.eng.osaka-u.ac.jp
A classical molecular dynamics simulation was conducted for a system composed of fluid molecules between two planar solid surfaces, and whose interactions are described by the 12-6 Lennard-Jones form. This paper presents a general description of the pressure components and interfacial tension at a fluid-solid interface obtained by the perturbative method on the basis of statistical thermodynamics, proposes a method to consider the pressure components tangential to an interface which are affected by interactions with solid atoms, and applies this method to the calculation system. The description of the perturbative method is extended to subsystems, and the local pressure componentsmore » and interfacial tension at a liquid-solid interface are obtained and examined in one- and two-dimensions. The results are compared with those obtained by two alternative methods: (a) an evaluation of the intermolecular force acting on a plane, and (b) the conventional method based on the virial expression. The accuracy of the numerical results is examined through the comparison of the results obtained by each method. The calculated local pressure components and interfacial tension of the fluid at a liquid-solid interface agreed well with the results of the two alternative methods at each local position in one dimension. In two dimensions, the results showed a characteristic profile of the tangential pressure component which depended on the direction tangential to the liquid-solid interface, which agreed with that obtained by the evaluation of the intermolecular force acting on a plane in the present study. Such good agreement suggests that the perturbative method on the basis of statistical thermodynamics used in this study is valid to obtain the local pressure components and interfacial tension at a liquid-solid interface.« less
Laser Pencil Beam Based Techniques for Visualization and Analysis of Interfaces Between Media
NASA Technical Reports Server (NTRS)
Adamovsky, Grigory; Giles, Sammie, Jr.
1998-01-01
Traditional optical methods that include interferometry, Schlieren, and shadowgraphy have been used successfully for visualization and evaluation of various media. Aerodynamics and hydrodynamics are major fields where these methods have been applied. However, these methods have such major drawbacks as a relatively low power density and suppression of the secondary order phenomena. A novel method introduced at NASA Lewis Research Center minimizes disadvantages of the 'classical' methods. The method involves a narrow pencil-like beam that penetrates a medium of interest. The paper describes the laser pencil beam flow visualization methods in detail. Various system configurations are presented. The paper also discusses interfaces between media in general terms and provides examples of interfaces.
Development and evaluation of nursing user interface screens using multiple methods.
Hyun, Sookyung; Johnson, Stephen B; Stetson, Peter D; Bakken, Suzanne
2009-12-01
Building upon the foundation of the Structured Narrative Electronic Health Record (EHR) model, we applied theory-based (combined Technology Acceptance Model and Task-Technology Fit Model) and user-centered methods to explore nurses' perceptions of functional requirements for an electronic nursing documentation system, design user interface screens reflective of the nurses' perspectives, and assess nurses' perceptions of the usability of the prototype user interface screens. The methods resulted in user interface screens that were perceived to be easy to use, potentially useful, and well-matched to nursing documentation tasks associated with Nursing Admission Assessment, Blood Administration, and Nursing Discharge Summary. The methods applied in this research may serve as a guide for others wishing to implement user-centered processes to develop or extend EHR systems. In addition, some of the insights obtained in this study may be informative to the development of safe and efficient user interface screens for nursing document templates in EHRs.
ρ-VOF: An interface sharpening method for gas-liquid flow simulation
NASA Astrophysics Data System (ADS)
Wang, Jiantao; Liu, Gang; Jiang, Xiong; Mou, Bin
2018-05-01
The study on simulation of compressible gas-liquid flow remains open. Popular methods are either confined to incompressible flow regime, or inevitably induce smear of the free interface. A new finite volume method for compressible two-phase flow simulation is contributed for this subject. First, the “heterogeneous equilibrium” assumption is introduced to the control volume, by hiring free interface reconstruction technology, the distribution of each component in the control volume is achieved. Next, AUSM+-up (advection upstream splitting method) scheme is employed to calculate the convective fluxes and pressure fluxes, with the contact discontinuity characteristic considered, followed by the update of the whole flow field. The new method features on density-based pattern and interface reconstruction technology from VOF (volume of fluid), thus we name it “ρ-VOF method”. Inherited from AUSM families and VOF, ρ-VOF behaves as an all-speed method, capable of simulating shock in gas-liquid flow, and preserving the sharpness of the free interface. Gas-liquid shock tube is simulated to evaluate the method, from which good agreement is obtained between the predicted results and those of the cited literature, meanwhile, sharper free interface is identified. Finally, the capability and validity of ρ-VOF method can be concluded in compressible gas-liquid flow simulation.
Assessing performance of an Electronic Health Record (EHR) using Cognitive Task Analysis.
Saitwal, Himali; Feng, Xuan; Walji, Muhammad; Patel, Vimla; Zhang, Jiajie
2010-07-01
Many Electronic Health Record (EHR) systems fail to provide user-friendly interfaces due to the lack of systematic consideration of human-centered computing issues. Such interfaces can be improved to provide easy to use, easy to learn, and error-resistant EHR systems to the users. To evaluate the usability of an EHR system and suggest areas of improvement in the user interface. The user interface of the AHLTA (Armed Forces Health Longitudinal Technology Application) was analyzed using the Cognitive Task Analysis (CTA) method called GOMS (Goals, Operators, Methods, and Selection rules) and an associated technique called KLM (Keystroke Level Model). The GOMS method was used to evaluate the AHLTA user interface by classifying each step of a given task into Mental (Internal) or Physical (External) operators. This analysis was performed by two analysts independently and the inter-rater reliability was computed to verify the reliability of the GOMS method. Further evaluation was performed using KLM to estimate the execution time required to perform the given task through application of its standard set of operators. The results are based on the analysis of 14 prototypical tasks performed by AHLTA users. The results show that on average a user needs to go through 106 steps to complete a task. To perform all 14 tasks, they would spend about 22 min (independent of system response time) for data entry, of which 11 min are spent on more effortful mental operators. The inter-rater reliability analysis performed for all 14 tasks was 0.8 (kappa), indicating good reliability of the method. This paper empirically reveals and identifies the following finding related to the performance of AHLTA: (1) large number of average total steps to complete common tasks, (2) high average execution time and (3) large percentage of mental operators. The user interface can be improved by reducing (a) the total number of steps and (b) the percentage of mental effort, required for the tasks. 2010 Elsevier Ireland Ltd. All rights reserved.
Binding free energy analysis of protein-protein docking model structures by evERdock.
Takemura, Kazuhiro; Matubayasi, Nobuyuki; Kitao, Akio
2018-03-14
To aid the evaluation of protein-protein complex model structures generated by protein docking prediction (decoys), we previously developed a method to calculate the binding free energies for complexes. The method combines a short (2 ns) all-atom molecular dynamics simulation with explicit solvent and solution theory in the energy representation (ER). We showed that this method successfully selected structures similar to the native complex structure (near-native decoys) as the lowest binding free energy structures. In our current work, we applied this method (evERdock) to 100 or 300 model structures of four protein-protein complexes. The crystal structures and the near-native decoys showed the lowest binding free energy of all the examined structures, indicating that evERdock can successfully evaluate decoys. Several decoys that show low interface root-mean-square distance but relatively high binding free energy were also identified. Analysis of the fraction of native contacts, hydrogen bonds, and salt bridges at the protein-protein interface indicated that these decoys were insufficiently optimized at the interface. After optimizing the interactions around the interface by including interfacial water molecules, the binding free energies of these decoys were improved. We also investigated the effect of solute entropy on binding free energy and found that consideration of the entropy term does not necessarily improve the evaluations of decoys using the normal model analysis for entropy calculation.
Binding free energy analysis of protein-protein docking model structures by evERdock
NASA Astrophysics Data System (ADS)
Takemura, Kazuhiro; Matubayasi, Nobuyuki; Kitao, Akio
2018-03-01
To aid the evaluation of protein-protein complex model structures generated by protein docking prediction (decoys), we previously developed a method to calculate the binding free energies for complexes. The method combines a short (2 ns) all-atom molecular dynamics simulation with explicit solvent and solution theory in the energy representation (ER). We showed that this method successfully selected structures similar to the native complex structure (near-native decoys) as the lowest binding free energy structures. In our current work, we applied this method (evERdock) to 100 or 300 model structures of four protein-protein complexes. The crystal structures and the near-native decoys showed the lowest binding free energy of all the examined structures, indicating that evERdock can successfully evaluate decoys. Several decoys that show low interface root-mean-square distance but relatively high binding free energy were also identified. Analysis of the fraction of native contacts, hydrogen bonds, and salt bridges at the protein-protein interface indicated that these decoys were insufficiently optimized at the interface. After optimizing the interactions around the interface by including interfacial water molecules, the binding free energies of these decoys were improved. We also investigated the effect of solute entropy on binding free energy and found that consideration of the entropy term does not necessarily improve the evaluations of decoys using the normal model analysis for entropy calculation.
Study on cord/rubber interface at elevated temperatures by H-pull test method
NASA Astrophysics Data System (ADS)
Jamshidi, M.; Afshar, F.; Mohammadi, N.; Pourmahdian, S.
2005-08-01
Cords are used as reinforcing materials in rubber compounds. To increase cord/rubber interfacial adhesion, they are coated by an adhesive (usually based on resorcinol-formaldehyde-latex). These composites are used in many sectors such as tire and belt industries. Cord/rubber adhesion strength is an important aspect to determine the durability of system. Due to temperature increase during running tires, the adhesion energy becomes different from initial one. To study cord/rubber interface at elevated temperatures, H-adhesion test method was used. H-pull test is a simple method for adhesion evaluation at ambient temperature, so it is usually used for material quality control. In this research, cord/rubber systems were vulcanized at different temperatures and H-adhesion of samples were evaluated at elevated temperatures. Also cord/rubber interface was studied by ATR analyze to determine interfacial interactions kind.
NASA Astrophysics Data System (ADS)
Lan, Chunbo; Tang, Lihua; Harne, Ryan L.
2018-05-01
Nonlinear piezoelectric energy harvester (PEH) has been widely investigated during the past few years. Among the majority of these researches, a pure resistive load is used to evaluate power output. To power conventional electronics in practical application, the alternating current (AC) generated by nonlinear PEH needs to be transformed into a direct current (DC) and rectifying circuits are required to interface the device and electronic load. This paper aims at exploring the critical influences of AC and DC interface circuits on nonlinear PEH. As a representative nonlinear PEH, we fabricate and evaluate a monostable PEH in terms of generated power and useful operating bandwidth when it is connected to AC and DC interface circuits. Firstly, the harmonic balance analysis and equivalent circuit representation method are utilized to tackle the modeling of nonlinear energy harvesters connected to AC and DC interface circuits. The performances of the monostable PEH connected to these interface circuits are then analyzed and compared, focusing on the influences of the varying load, excitation and electromechanical coupling strength on the nonlinear dynamics, bandwidth and harvested power. Subsequently, the behaviors of the monostable PEH with AC and DC interface circuits are verified by experiment. Results indicate that both AC and DC interface circuits have a peculiar influence on the power peak shifting and operational bandwidth of the monostable PEH, which is quite different from that on the linear PEH.
An induced current method for measuring zeta potential of electrolyte solution-air interface.
Song, Yongxin; Zhao, Kai; Wang, Junsheng; Wu, Xudong; Pan, Xinxiang; Sun, Yeqing; Li, Dongqing
2014-02-15
This paper reports a novel and very simple method for measuring the zeta potential of electrolyte solution-air interface. When a measuring electrode contacts the electrolyte solution-air interface, an electrical current will be generated due to the potential difference between the electrode-air surface and the electrolyte solution-air interface. The amplitude of the measured electric signal is linearly proportional to this potential difference; and depends only on the zeta potential at the electrolyte solution-air interface, regardless of the types and concentrations of the electrolyte. A correlation between the zeta potential and the measured voltage signal is obtained based on the experimental data. Using this equation, the zeta potential of any electrolyte solution-air interface can be evaluated quickly and easily by inserting an electrode through the electrolyte solution-air interface and measuring the electrical signal amplitude. This method was verified by comparing the obtained results of NaCl, MgCl2 and CaCl2 solutions of different pH values and concentrations with the zeta potential data reported in the published journal papers. Copyright © 2013 Elsevier Inc. All rights reserved.
Support of surgical process modeling by using adaptable software user interfaces
NASA Astrophysics Data System (ADS)
Neumuth, T.; Kaschek, B.; Czygan, M.; Goldstein, D.; Strauß, G.; Meixensberger, J.; Burgert, O.
2010-03-01
Surgical Process Modeling (SPM) is a powerful method for acquiring data about the evolution of surgical procedures. Surgical Process Models are used in a variety of use cases including evaluation studies, requirements analysis and procedure optimization, surgical education, and workflow management scheme design. This work proposes the use of adaptive, situation-aware user interfaces for observation support software for SPM. We developed a method to support the modeling of the observer by using an ontological knowledge base. This is used to drive the graphical user interface for the observer to restrict the search space of terminology depending on the current situation. In the evaluation study it is shown, that the workload of the observer was decreased significantly by using adaptive user interfaces. 54 SPM observation protocols were analyzed by using the NASA Task Load Index and it was shown that the use of the adaptive user interface disburdens the observer significantly in workload criteria effort, mental demand and temporal demand, helping him to concentrate on his essential task of modeling the Surgical Process.
Assessment of Protein Side-Chain Conformation Prediction Methods in Different Residue Environments
Peterson, Lenna X.; Kang, Xuejiao; Kihara, Daisuke
2016-01-01
Computational prediction of side-chain conformation is an important component of protein structure prediction. Accurate side-chain prediction is crucial for practical applications of protein structure models that need atomic detailed resolution such as protein and ligand design. We evaluated the accuracy of eight side-chain prediction methods in reproducing the side-chain conformations of experimentally solved structures deposited to the Protein Data Bank. Prediction accuracy was evaluated for a total of four different structural environments (buried, surface, interface, and membrane-spanning) in three different protein types (monomeric, multimeric, and membrane). Overall, the highest accuracy was observed for buried residues in monomeric and multimeric proteins. Notably, side-chains at protein interfaces and membrane-spanning regions were better predicted than surface residues even though the methods did not all use multimeric and membrane proteins for training. Thus, we conclude that the current methods are as practically useful for modeling protein docking interfaces and membrane-spanning regions as for modeling monomers. PMID:24619909
Method for non-destructive evaluation of ceramic coatings
Peterson, Kristen A.; Rosen, Elias P.; Jordan, Eric H.; Shahbazmohamadi, Sina; Vakhtin, Andrei B.
2016-11-08
A method for evaluating the condition of a ceramic coating deposited on a substrate comprising illuminating the ceramic coating with light, measuring the intensity of light returned from the ceramic coating as function of depth in the coating and transverse position on the coating, and analyzing the measured light intensities to obtain one or more of intensity of the light returned from the exposed coating surface relative to the intensity of light returned from the coating/substrate interface, intensity of the light returned from the coating/substrate interface relative to the intensity of light returned from the bulk of the ceramic coating, determination of roughness at the exposed surface of the ceramic coating, and determination of roughness of the interface between the ceramic coating and underlying bond coat or substrate.
Incorporating contact angles in the surface tension force with the ACES interface curvature scheme
NASA Astrophysics Data System (ADS)
Owkes, Mark
2017-11-01
In simulations of gas-liquid flows interacting with solid boundaries, the contact line dynamics effect the interface motion and flow field through the surface tension force. The surface tension force is directly proportional to the interface curvature and the problem of accurately imposing a contact angle must be incorporated into the interface curvature calculation. Many commonly used algorithms to compute interface curvatures (e.g., height function method) require extrapolating the interface, with defined contact angle, into the solid to allow for the calculation of a curvature near a wall. Extrapolating can be an ill-posed problem, especially in three-dimensions or when multiple contact lines are near each other. We have developed an accurate methodology to compute interface curvatures that allows for contact angles to be easily incorporated while avoiding extrapolation and the associated challenges. The method, known as Adjustable Curvature Evaluation Scale (ACES), leverages a least squares fit of a polynomial to points computed on the volume-of-fluid (VOF) representation of the gas-liquid interface. The method is tested by simulating canonical test cases and then applied to simulate the injection and motion of water droplets in a channel (relevant to PEM fuel cells).
'Fly Like This': Natural Language Interface for UAV Mission Planning
NASA Technical Reports Server (NTRS)
Chandarana, Meghan; Meszaros, Erica L.; Trujillo, Anna; Allen, B. Danette
2017-01-01
With the increasing presence of unmanned aerial vehicles (UAVs) in everyday environments, the user base of these powerful and potentially intelligent machines is expanding beyond exclusively highly trained vehicle operators to include non-expert system users. Scientists seeking to augment costly and often inflexible methods of data collection historically used are turning towards lower cost and reconfigurable UAVs. These new users require more intuitive and natural methods for UAV mission planning. This paper explores two natural language interfaces - gesture and speech - for UAV flight path generation through individual user studies. Subjects who participated in the user studies also used a mouse-based interface for a baseline comparison. Each interface allowed the user to build flight paths from a library of twelve individual trajectory segments. Individual user studies evaluated performance, efficacy, and ease-of-use of each interface using background surveys, subjective questionnaires, and observations on time and correctness. Analysis indicates that natural language interfaces are promising alternatives to traditional interfaces. The user study data collected on the efficacy and potential of each interface will be used to inform future intuitive UAV interface design for non-expert users.
Radial-based tail methods for Monte Carlo simulations of cylindrical interfaces
NASA Astrophysics Data System (ADS)
Goujon, Florent; Bêche, Bruno; Malfreyt, Patrice; Ghoufi, Aziz
2018-03-01
In this work, we implement for the first time the radial-based tail methods for Monte Carlo simulations of cylindrical interfaces. The efficiency of this method is then evaluated through the calculation of surface tension and coexisting properties. We show that the inclusion of tail corrections during the course of the Monte Carlo simulation impacts the coexisting and the interfacial properties. We establish that the long range corrections to the surface tension are the same order of magnitude as those obtained from planar interface. We show that the slab-based tail method does not amend the localization of the Gibbs equimolar dividing surface. Additionally, a non-monotonic behavior of surface tension is exhibited as a function of the radius of the equimolar dividing surface.
Estimation of muscle strength during motion recognition using multichannel surface EMG signals.
Nagata, Kentaro; Nakano, Takemi; Magatani, Kazushige; Yamada, Masafumi
2008-01-01
The use of kinesiological electromyography is established as an evaluation tool for various kinds of applied research, and surface electromyogram (SEMG) has been widely used as a control source for human interfaces such as in a myoelectric prosthetic hand (we call them 'SEMG interfaces'). It is desirable to be able to control the SEMG interfaces with the same feeling as body movement. The existing SEMG interface mainly focuses on how to achieve accurate recognition of the intended movement. However, detecting muscular strength and reduced number of electrodes are also an important factor in controlling them. Therefore, our objective in this study is the development of and the estimation method for muscular strength that maintains the accuracy of hand motion recognition to reflect the result of measured power in a controlled object. Although the muscular strength can be evaluated by various methods, in this study a grasp force index was applied to evaluate the muscular strength. In order to achieve our objective, we directed our attention to measuring all valuable information for SEMG. This work proposes an application method of two simple linear models, and the selection method of an optimal electrode configuration to use them effectively. Our system required four SEMG measurement electrodes in which locations differed for every subject depending on the individual's characteristics, and those were selected from a 96ch multi electrode using the Monte Carlo method. From the experimental results, the performance in six normal subjects indicated that the recognition rate of four motions were perfect and the grasp force estimated result fit well with the actual measurement result.
NASA Astrophysics Data System (ADS)
Peng, Zhao-Yang; Wang, Sheng-Kai; Bai, Yun; Tang, Yi-Dan; Chen, Xi-Ming; Li, Cheng-Zhan; Liu, Ke-An; Liu, Xin-Yu
2018-04-01
In this work, border traps located in SiO2 at different depths in 4H-SiC MOS system are evaluated by a simple and effective method based on capacitance-voltage (C-V) measurements. This method estimates the border traps between two adjacent depths through C-V measurement at various frequencies at room and elevated temperatures. By comparison of these two C-V characteristics, the correlation between time constant of border traps and temperatures is obtained. Then the border trap density is determined by integration of capacitance difference against gate voltage at the regions where border traps dominate. The results reveal that border trap concentration a few nanometers away from the interface increases exponentially towards the interface, which is in good agreement with previous work. It has been proved that high temperature 1 MHz C-V method is effective for border trap evaluation.
A methodology for evaluating the usability of audiovisual consumer electronic products.
Kwahk, Jiyoung; Han, Sung H
2002-09-01
Usability evaluation is now considered an essential procedure in consumer product development. Many studies have been conducted to develop various techniques and methods of usability evaluation hoping to help the evaluators choose appropriate methods. However, planning and conducting usability evaluation requires considerations of a number of factors surrounding the evaluation process including the product, user, activity, and environmental characteristics. In this perspective, this study suggested a new methodology of usability evaluation through a simple, structured framework. The framework was outlined by three major components: the interface features of a product as design variables, the evaluation context consisting of user, product, activity, and environment as context variables, and the usability measures as dependent variables. Based on this framework, this study established methods to specify the product interface features, to define evaluation context, and to measure usability. The effectiveness of this methodology was demonstrated through case studies in which the usability of audiovisual products was evaluated by using the methods developed in this study. This study is expected to help the usability practitioners in consumer electronics industry in various ways. Most directly, it supports the evaluators' plan and conduct usability evaluation sessions in a systematic and structured manner. In addition, it can be applied to other categories of consumer products (such as appliances, automobiles, communication devices, etc.) with minor modifications as necessary.
Gradient-augmented hybrid interface capturing method for incompressible two-phase flow
NASA Astrophysics Data System (ADS)
Zheng, Fu; Shi-Yu, Wu; Kai-Xin, Liu
2016-06-01
Motivated by inconveniences of present hybrid methods, a gradient-augmented hybrid interface capturing method (GAHM) is presented for incompressible two-phase flow. A front tracking method (FTM) is used as the skeleton of the GAHM for low mass loss and resources. Smooth eulerian level set values are calculated from the FTM interface, and are used for a local interface reconstruction. The reconstruction avoids marker particle redistribution and enables an automatic treatment of interfacial topology change. The cubic Hermit interpolation is employed in all steps of the GAHM to capture subgrid structures within a single spacial cell. The performance of the GAHM is carefully evaluated in a benchmark test. Results show significant improvements of mass loss, clear subgrid structures, highly accurate derivatives (normals and curvatures) and low cost. The GAHM is further coupled with an incompressible multiphase flow solver, Super CE/SE, for more complex and practical applications. The updated solver is evaluated through comparison with an early droplet research. Project supported by the National Natural Science Foundation of China (Grant Nos. 10972010, 11028206, 11371069, 11372052, 11402029, and 11472060), the Science and Technology Development Foundation of China Academy of Engineering Physics (CAEP), China (Grant No. 2014B0201030), and the Defense Industrial Technology Development Program of China (Grant No. B1520132012).
A simple method for determining stress intensity factors for a crack in bi-material interface
NASA Astrophysics Data System (ADS)
Morioka, Yuta
Because of violently oscillating nature of stress and displacement fields near the crack tip, it is difficult to obtain stress intensity factors for a crack between two dis-similar media. For a crack in a homogeneous medium, it is a common practice to find stress intensity factors through strain energy release rates. However, individual strain energy release rates do not exist for bi-material interface crack. Hence it is necessary to find alternative methods to evaluate stress intensity factors. Several methods have been proposed in the past. However they involve mathematical complexity and sometimes require additional finite element analysis. The purpose of this research is to develop a simple method to find stress intensity factors in bi-material interface cracks. A finite element based projection method is proposed in the research. It is shown that the projection method yields very accurate stress intensity factors for a crack in isotropic and anisotropic bi-material interfaces. The projection method is also compared to displacement ratio method and energy method proposed by other authors. Through comparison it is found that projection method is much simpler to apply with its accuracy comparable to that of displacement ratio method.
A quantitative study of factors influencing lamellar eutectic morphology during solidification
NASA Technical Reports Server (NTRS)
Kaukler, W. F. S.
1981-01-01
The factors that influence the shape of the solid-liquid interface of a lamellar binary eutectic alloy are evaluated. Alloys of carbon tetrabromide and hexachloroethane which serve as a transparent analogue of lamellar metallic eutectics are used. The observed interface shapes are analyzed by computer-aided methods. The solid-liquid interfacial free energies of each of the individual phases comprising the eutectic system are measured as a function of composition using a 'grain boundary groove' technique. The solid-liquid interfacial free energy of the two phases are evaluated directly from the eutectic interface. The phase diagram for the system, the heat of fusion as a function of composition, and the density as a function of composition are measured. The shape of the eutectic interface is controlled mainly by the solid-liquid and solid-solid interfacial free energy relationships at the interface and by the temperature gradient present, rather than by interlamellar diffusion in the liquid at the interface, over the range of growth rates studied.
2014-01-01
Background Clinical practice guidelines are useful for physicians, and guidelines are available on the Internet from various websites such as Vidal Recos. However, these guidelines are long and difficult to read, especially during consultation. Similar difficulties have been encountered with drug summaries of product characteristics. In a previous work, we have proposed an iconic language (called VCM, for Visualization of Concepts in Medicine) for representing patient conditions, treatments and laboratory tests, and we have used these icons to design a user interface that graphically indexes summaries of product characteristics. In the current study, our objective was to design and evaluate an iconic user interface for the consultation of clinical practice guidelines by physicians. Methods Focus groups of physicians were set up to identify the difficulties encountered when reading guidelines. Icons were integrated into Vidal Recos, taking human factors into account. The resulting interface includes a graphical summary and an iconic indexation of the guideline. The new interface was evaluated. We compared the response times and the number of errors recorded when physicians answered questions about two clinical scenarios using the interactive iconic interface or a textual interface. Users’ perceived usability was evaluated with the System Usability Scale. Results The main difficulties encountered by physicians when reading guidelines were obtaining an overview and finding recommendations for patients corresponding to “particular cases”. We designed a graphical interface for guideline consultation, using icons to identify particular cases and providing a graphical summary of the icons organized by anatomy and etiology. The evaluation showed that physicians gave clinical responses more rapidly with the iconic interface than the textual interface (25.2 seconds versus 45.6, p < 0.05). The physicians appreciated the new interface, and the System Usability Scale score value was 75 (between good and excellent). Conclusion An interactive iconic interface can provide physicians with an overview of clinical practice guidelines, and can decrease the time required to access the content of such guidelines. PMID:25158762
NASA Astrophysics Data System (ADS)
de Laborderie, J.; Duchaine, F.; Gicquel, L.; Vermorel, O.; Wang, G.; Moreau, S.
2018-06-01
Large-Eddy Simulation (LES) is recognized as a promising method for high-fidelity flow predictions in turbomachinery applications. The presented approach consists of the coupling of several instances of the same LES unstructured solver through an overset grid method. A high-order interpolation, implemented within this coupling method, is introduced and evaluated on several test cases. It is shown to be third order accurate, to preserve the accuracy of various second and third order convective schemes and to ensure the continuity of diffusive fluxes and subgrid scale tensors even in detrimental interface configurations. In this analysis, three types of spurious waves generated at the interface are identified. They are significantly reduced by the high-order interpolation at the interface. The latter having the same cost as the original lower order method, the high-order overset grid method appears as a promising alternative to be used in all the applications.
3D hierarchical interface-enriched finite element method: Implementation and applications
NASA Astrophysics Data System (ADS)
Soghrati, Soheil; Ahmadian, Hossein
2015-10-01
A hierarchical interface-enriched finite element method (HIFEM) is proposed for the mesh-independent treatment of 3D problems with intricate morphologies. The HIFEM implements a recursive algorithm for creating enrichment functions that capture gradient discontinuities in nonconforming finite elements cut by arbitrary number and configuration of materials interfaces. The method enables the mesh-independent simulation of multiphase problems with materials interfaces that are in close proximity or contact while providing a straightforward general approach for evaluating the enrichments. In this manuscript, we present a detailed discussion on the implementation issues and required computational geometry considerations associated with the HIFEM approximation of thermal and mechanical responses of 3D problems. A convergence study is provided to investigate the accuracy and convergence rate of the HIFEM and compare them with standard FEM benchmark solutions. We will also demonstrate the application of this mesh-independent method for simulating the thermal and mechanical responses of two composite materials systems with complex microstructures.
NASA Astrophysics Data System (ADS)
Zhao, Peng; Khosravi, Ava; Azcatl, Angelica; Bolshakov, Pavel; Mirabelli, Gioele; Caruso, Enrico; Hinkle, Christopher L.; Hurley, Paul K.; Wallace, Robert M.; Young, Chadwin D.
2018-07-01
Border traps and interface traps in HfO2/few-layer MoS2 top-gate stacks are investigated by C–V characterization. Frequency dependent C–V data shows dispersion in both the depletion and accumulation regions for the MoS2 devices. The border trap density is extracted with a distributed model, and interface traps are analyzed using the high-low frequency and multi-frequency methods. The physical origins of interface traps appear to be caused by impurities/defects in the MoS2 layers, performing as band tail states, while the border traps are associated with the dielectric, likely a consequence of the low-temperature deposition. This work provides a method of using multiple C–V measurements and analysis techniques to analyze the behavior of high-k/TMD gate stacks and deconvolute border traps from interface traps.
NASA Technical Reports Server (NTRS)
1982-01-01
A highly thromboresistant blood contacting interface for use in implanatable blood pump is investigated. Biomaterials mechanics, dynamics, durability, surface morphology, and chemistry are among the critical consideration pertinent to the choice of an appropriate blood pump bladder material. The use of transfer cast biopolymers from ion beam textured surfaces is investigated to detect subtle variations in blood pump surface morphology using Biomer as the biomaterial of choice. The efficacy of ion beam sputtering as an acceptable method of fabricating textured blood interfaces is evaluated. Aortic grafts and left ventricular assist devices were implanted in claves; the blood interfaces were fabricated by transfer casting methods from ion beam textured polytetrafluorethylene mandrels. The mandrels were textured by superimposing a 15 micron screen mesh; ion sputtering conditions were 300 volts beam energy, 40 to 50 mA beam, and a mandrel to source distance of 25 microns.
Evaluation of Telerobotic Interface Components for Teaching Robot Operation
ERIC Educational Resources Information Center
Goldstain, Ofir H.; Ben-Gal, Irad; Bukchin, Yossi
2011-01-01
Remote learning has been an increasingly growing field in the last two decades. The Internet development, as well as the increase in PC's capabilities and bandwidth capacity, has made remote learning through the internet a convenient learning preference, leading to a variety of new interfaces and methods. In this work, we consider a remote…
Partsch, Hugo; Clark, Michael; Bassez, Sophie; Benigni, Jean-Patrick; Becker, Francis; Blazek, Vladimir; Caprini, Joseph; Cornu-Thénard, André; Hafner, Jürg; Flour, Mieke; Jünger, Michael; Moffatt, Christine; Neumann, Martino
2006-02-01
Interface pressure and stiffness characterizing the elastic properties of the material are the parameters determining the dosage of compression treatment and should therefore be measured in future clinical trials. To provide some recommendations regarding the use of suitable methods for this indication. This article was formulated based on the results of an international consensus meeting between a group of medical experts and representatives from the industry held in January 2005 in Vienna, Austria. Proposals are made concerning methods for measuring the interface pressure and for assessing the stiffness of a compression device in an individual patient. In vivo measurement of interface pressure is encouraged when clinical and experimental outcomes of compression treatment are to be evaluated.
Flight Force Measurements on a Spacecraft to Launch Vehicle Interface
NASA Astrophysics Data System (ADS)
Kaufman, Daniel S.; Gordon, Scott A.
2012-07-01
For several years we had wanted to measure interface forces between a launch vehicle and the Payload. Finally in July 2006 a proposal was made and funded to evaluate the use of flight force measurements (FFM) to improve the loads process of a Spacecraft in its design and test cycle. A NASA/Industry team was formed, the core Team consisted of 20 people. The proposal identified two questions that this assessment would attempt to address by obtaining the flight forces. These questions were: 1) Is flight correlation and reconstruction with acceleration methods sufficient? 2) How much can the loads and therefore the design and qualification be reduced by having force measurements? The objective was to predict the six interface driving forces between the Spacecraft and the Launch Vehicle throughout the boost phase. Then these forces would be compared with reconstructed loads analyses for evaluation in an attempt to answer them. The paper will present the development of a strain based force measurement system and also an acceleration method, actual flight results, post flight evaluations and lessons learned.
ERIC Educational Resources Information Center
Moghimi, Saba; Kushki, Azadeh; Guerguerian, Anne Marie; Chau, Tom
2013-01-01
Electroencephalography (EEG) is a non-invasive method for measuring brain activity and is a strong candidate for brain-computer interface (BCI) development. While BCIs can be used as a means of communication for individuals with severe disabilities, the majority of existing studies have reported BCI evaluations by able-bodied individuals.…
A usability evaluation of a SNOMED CT based compositional interface terminology for intensive care.
Bakhshi-Raiez, F; de Keizer, N F; Cornet, R; Dorrepaal, M; Dongelmans, D; Jaspers, M W M
2012-05-01
To evaluate the usability of a large compositional interface terminology based on SNOMED CT and the terminology application for registration of the reasons for intensive care admission in a Patient Data Management System. Observational study with user-based usability evaluations before and 3 months after the system was implemented and routinely used. Usability was defined by five aspects: effectiveness, efficiency, learnability, overall user satisfaction, and experienced usability problems. Qualitative (the Think-Aloud user testing method) and quantitative (the System Usability Scale questionnaire and Time-on-Task analyses) methods were used to examine these usability aspects. The results of the evaluation study revealed that the usability of the interface terminology fell short (SUS scores before and after implementation of 47.2 out of 100 and 37.5 respectively out of 100). The qualitative measurements revealed a high number (n=35) of distinct usability problems, leading to ineffective and inefficient registration of reasons for admission. The effectiveness and efficiency of the system did not change over time. About 14% (n=5) of the revealed usability problems were related to the terminology content based on SNOMED CT, while the remaining 86% (n=30) was related to the terminology application. The problems related to the terminology content were more severe than the problems related to the terminology application. This study provides a detailed insight into how clinicians interact with a controlled compositional terminology through a terminology application. The extensiveness, complexity of the hierarchy, and the language usage of an interface terminology are defining for its usability. Carefully crafted domain-specific subsets and a well-designed terminology application are needed to facilitate the use of a complex compositional interface terminology based on SNOMED CT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Evaluation of pH at the Bacteria–Dental Cement Interface
Mayanagi, G.; Igarashi, K.; Washio, J.; Nakajo, K.; Domon-Tawaraya, H.; Takahashi, N.
2011-01-01
Physiochemical assessment of the parasite-biomaterial interface is essential in the development of new biomaterials. The purpose of this study was to develop a method to evaluate pH at the bacteria-dental cement interface and to demonstrate physiochemical interaction at the interface. The experimental apparatus with a well (4.0 mm in diameter and 2.0 mm deep) was made of polymethyl methacrylate with dental cement or polymethyl methacrylate (control) at the bottom. Three representative dental cements (glass-ionomer, zinc phosphate, and zinc oxide-eugenol cements) were used. Each specimen was immersed in 2 mM potassium phosphate buffer for 10 min, 24 hrs, 1 wk, or 4 wks. The well was packed with Streptococcus mutans NCTC 10449, and a miniature pH electrode was placed at the interface between bacterial cells and dental cement. The pH was monitored after the addition of 1% glucose, and the fluoride contained in the cells was quantified. Glass-ionomer cement inhibited the bacteria-induced pH fall significantly compared with polymethyl methacrylate (control) at the interface (10 min, 5.16 ± 0.19 vs. 4.50 ± 0.07; 24 hrs, 5.20 ± 0.07 vs. 4.59 ± 0.11; 1 wk, 5.34 ± 0.14 vs. 4.57 ± 0.11; and 4 wks, 4.95 ± 0.27 vs. 4.40 ± 0.14), probably due to the fluoride released from the cement. This method could be useful for the assessment of pH at the parasite-biomaterial interface. PMID:21933936
Demiris, A M; Meinzer, H P
1997-01-01
Whether or not a computerized system enhances the conditions of work in the application domain, very much demands on the user interface. Graphical user interfaces seem to attract the interest of the users but mostly ignore some basic rules of visual information processing thus leading to systems which are difficult to use, lowering productivity and increasing working stress (cognitive and work load). In this work we present some fundamental ergonomic considerations and their application to the medical image processing and archiving domain. We introduce the extensions to an existing concept needed to control and guide the development of GUIs with respect to domain specific ergonomics. The suggested concept, called Model-View-Controller Constraints (MVCC), can be used to programmatically implement ergonomic constraints, and thus has some advantages over written style guides. We conclude with the presentation of existing norms and methods to evaluate user interfaces.
Fast Solvers for Moving Material Interfaces
2008-01-01
interface method—with the semi-Lagrangian contouring method developed in References [16–20]. We are now finalizing portable C / C ++ codes for fast adaptive ...stepping scheme couples a CIR predictor with a trapezoidal corrector using the velocity evaluated from the CIR approximation. It combines the...formula with efficient geometric algorithms and fast accurate contouring techniques. A modular adaptive implementation with fast new geometry modules
Human Machine Interfaces for Teleoperators and Virtual Environments
NASA Technical Reports Server (NTRS)
Durlach, Nathaniel I. (Compiler); Sheridan, Thomas B. (Compiler); Ellis, Stephen R. (Compiler)
1991-01-01
In Mar. 1990, a meeting organized around the general theme of teleoperation research into virtual environment display technology was conducted. This is a collection of conference-related fragments that will give a glimpse of the potential of the following fields and how they interplay: sensorimotor performance; human-machine interfaces; teleoperation; virtual environments; performance measurement and evaluation methods; and design principles and predictive models.
Bordner, Andrew J; Gorin, Andrey A
2008-05-12
Protein-protein interactions are ubiquitous and essential for all cellular processes. High-resolution X-ray crystallographic structures of protein complexes can reveal the details of their function and provide a basis for many computational and experimental approaches. Differentiation between biological and non-biological contacts and reconstruction of the intact complex is a challenging computational problem. A successful solution can provide additional insights into the fundamental principles of biological recognition and reduce errors in many algorithms and databases utilizing interaction information extracted from the Protein Data Bank (PDB). We have developed a method for identifying protein complexes in the PDB X-ray structures by a four step procedure: (1) comprehensively collecting all protein-protein interfaces; (2) clustering similar protein-protein interfaces together; (3) estimating the probability that each cluster is relevant based on a diverse set of properties; and (4) combining these scores for each PDB entry in order to predict the complex structure. The resulting clusters of biologically relevant interfaces provide a reliable catalog of evolutionary conserved protein-protein interactions. These interfaces, as well as the predicted protein complexes, are available from the Protein Interface Server (PInS) website (see Availability and requirements section). Our method demonstrates an almost two-fold reduction of the annotation error rate as evaluated on a large benchmark set of complexes validated from the literature. We also estimate relative contributions of each interface property to the accurate discrimination of biologically relevant interfaces and discuss possible directions for further improving the prediction method.
NASA Astrophysics Data System (ADS)
Damianos, D.; Vitrant, G.; Lei, M.; Changala, J.; Kaminski-Cachopo, A.; Blanc-Pelissier, D.; Cristoloveanu, S.; Ionica, I.
2018-05-01
In this work, we investigate Second Harmonic Generation (SHG) as a non-destructive characterization method for Silicon-On-Insulator (SOI) materials. For thick SOI stacks, the SHG signal is related to the thickness variations of the different layers. However, in thin SOI films, the comparison between measurements and optical modeling suggests a supplementary SHG contribution attributed to the electric fields at the SiO2/Si interfaces. The impact of the electric field at each interface of the SOI on the SHG is assessed. The SHG technique can be used to evaluate interfacial electric fields and consequently interface charge density in SOI materials.
A Graphical User-Interface for Propulsion System Analysis
NASA Technical Reports Server (NTRS)
Curlett, Brian P.; Ryall, Kathleen
1992-01-01
NASA LeRC uses a series of computer codes to calculate installed propulsion system performance and weight. The need to evaluate more advanced engine concepts with a greater degree of accuracy has resulted in an increase in complexity of this analysis system. Therefore, a graphical user interface was developed to allow the analyst to more quickly and easily apply these codes. The development of this interface and the rationale for the approach taken are described. The interface consists of a method of pictorially representing and editing the propulsion system configuration, forms for entering numerical data, on-line help and documentation, post processing of data, and a menu system to control execution.
A graphical user-interface for propulsion system analysis
NASA Technical Reports Server (NTRS)
Curlett, Brian P.; Ryall, Kathleen
1993-01-01
NASA LeRC uses a series of computer codes to calculate installed propulsion system performance and weight. The need to evaluate more advanced engine concepts with a greater degree of accuracy has resulted in an increase in complexity of this analysis system. Therefore, a graphical user interface was developed to allow the analyst to more quickly and easily apply these codes. The development of this interface and the rationale for the approach taken are described. The interface consists of a method of pictorially representing and editing the propulsion system configuration, forms for entering numerical data, on-line help and documentation, post processing of data, and a menu system to control execution.
NASA Astrophysics Data System (ADS)
Song, Won-Seok; Kim, Seung-Gyu; Kim, Young-Cheon; Kwon, Dongil
2015-03-01
In this paper we propose a novel method, spherical indentation, for evaluation of the plastic properties of combined structures. Three-dimensional (3D) printed products, for example gradient metal alloys consisting of different kinds of material, contain interfaces that can act as weak points and threaten the mechanical reliability of products. Combined structures containing an interface between Cu alloy and Ag were prepared for testing. Samples were heat-treated at 100°C and 200°C for 3 h to optimize processing conditions. The indentation tensile properties of the samples were estimated by analyzing multiple loading-unloading curves obtained by use of the representative stress and strain method. A continuous increase in both yield strength and tensile strength was observed for the Cu alloy and the Cu/Ag interface after heat treatment at up to 200°C, because of precipitation hardening. These experimental results show that mechanical characterization of combined structures by spherical indentation is highly useful on the nano and micro scales.
Vasta, Robert; Crandell, Ian; Millican, Anthony; House, Leanna; Smith, Eric
2017-10-13
Microphone sensor systems provide information that may be used for a variety of applications. Such systems generate large amounts of data. One concern is with microphone failure and unusual values that may be generated as part of the information collection process. This paper describes methods and a MATLAB graphical interface that provides rapid evaluation of microphone performance and identifies irregularities. The approach and interface are described. An application to a microphone array used in a wind tunnel is used to illustrate the methodology.
Sun, Jin P; Dai, Jianhong; Song, Yan; Wang, You; Yang, Rui
2014-12-10
A basic understanding of the affinity between the hydroxyapatite (HA) and α-Ti surfaces is obtained through electronic structure calculations by first-principles method. The surface energies of HA(0001), HA (011̅0), HA (101̅1), and Ti(0001) surfaces have been calculated. The HA(0001) presents the most thermodynamically stable of HA. The HA/Ti interfaces were constructed by two kinds of interface models, the single interface (denoted as SI) and the double-interface (denoted as DI). Two methods, the full relaxation and the UBER, were applied to determine the interfacial separation and the atomic arrangement in the interfacial zone. The works of adhesion of interfaces with various stoichiometric HA surfaces were evaluated. For the HA(0001)/Ti(0001) interfaces, the work of adhesion is strongly dependent on the chemical environment of the HA surface. The values are -2.33, -1.52, and -0.80 J/m(2) for the none-, single-, and double-Ca terminated HA/Ti interfaces, respectively. The influence of atomic relaxation on the work of adhesion and interface separation is discussed. Full relaxation results include -1.99 J/m(2) work of adhesion and 0.220 nm separation between HA and Ti for the DI of 1-Ca-HA/Ti interface, while they are -1.14 J/m(2) and 0.235 nm by partial relaxation. Analysis of electronic structure reveals that charge transfer between HA and Ti slabs occurs during the formation of the HA/Ti interface. The transfer generates the Ti-O or Ti-Ca bonds across the interface and drives the HA/Ti interface system to metallic characteristic. The energetically favorable interfaces are formed when the outmost layer of HA comprises more O atoms at the interface.
Usability of a Patient Education and Motivation Tool Using Heuristic Evaluation
Arora, Mohit; Dai, Liwei; Price, Kathleen; Vizer, Lisa; Sears, Andrew
2009-01-01
Background Computer-mediated educational applications can provide a self-paced, interactive environment to deliver educational content to individuals about their health condition. These programs have been used to deliver health-related information about a variety of topics, including breast cancer screening, asthma management, and injury prevention. We have designed the Patient Education and Motivation Tool (PEMT), an interactive computer-based educational program based on behavioral, cognitive, and humanistic learning theories. The tool is designed to educate users and has three key components: screening, learning, and evaluation. Objective The objective of this tutorial is to illustrate a heuristic evaluation using a computer-based patient education program (PEMT) as a case study. The aims were to improve the usability of PEMT through heuristic evaluation of the interface; to report the results of these usability evaluations; to make changes based on the findings of the usability experts; and to describe the benefits and limitations of applying usability evaluations to PEMT. Methods PEMT was evaluated by three usability experts using Nielsen’s usability heuristics while reviewing the interface to produce a list of heuristic violations with severity ratings. The violations were sorted by heuristic and ordered from most to least severe within each heuristic. Results A total of 127 violations were identified with a median severity of 3 (range 0 to 4 with 0 = no problem to 4 = catastrophic problem). Results showed 13 violations for visibility (median severity = 2), 38 violations for match between system and real world (median severity = 2), 6 violations for user control and freedom (median severity = 3), 34 violations for consistency and standards (median severity = 2), 11 violations for error severity (median severity = 3), 1 violation for recognition and control (median severity = 3), 7 violations for flexibility and efficiency (median severity = 2), 9 violations for aesthetic and minimalist design (median severity = 2), 4 violations for help users recognize, diagnose, and recover from errors (median severity = 3), and 4 violations for help and documentation (median severity = 4). Conclusion We describe the heuristic evaluation method employed to assess the usability of PEMT, a method which uncovers heuristic violations in the interface design in a quick and efficient manner. Bringing together usability experts and health professionals to evaluate a computer-mediated patient education program can help to identify problems in a timely manner. This makes this method particularly well suited to the iterative design process when developing other computer-mediated health education programs. Heuristic evaluations provided a means to assess the user interface of PEMT. PMID:19897458
NASA Technical Reports Server (NTRS)
Spanos, P. D.; Cao, T. T.; Hamilton, D. A.; Nelson, D. A. R.
1989-01-01
An efficient method for the load analysis of Shuttle-payload systems with linear or nonlinear attachment interfaces is presented which allows the kinematics of the interface degrees of freedom at a given time to be evaluated without calculating the combined system modal representation of the Space Shuttle and its payload. For the case of a nonlinear dynamic model, an iterative procedure is employed to converge the nonlinear terms of the equations of motion to reliable values. Results are presented for a Shuttle abort landing event.
Lee, Sunwoo; Park, Junghyuck; Park, In-Sung; Ahn, Jinho
2014-07-01
We investigate the dependence of charge carrier mobility by trap states at various interface regions through channel engineering. Prior to evaluation of interface trap density, the electrical performance in pentaene field effect transistors (FET) with high-k gate oxide are also investigated depending on four channel engineering. As a channel engineering, gas treatment, coatings of thin polymer layer, and chemical surface modification using small molecules were carried out. After channel engineering, the performance of device as well as interface trap density calculated by conductance method are remarkably improved. It is found that the reduced interface trap density is closely related to decreasing the sub-threshold swing and improving the mobility. Particularly, we also found that performance of device such as mobility, subthreshold swing, and interface trap density after gas same is comparable to those of OTS.
Comparing two anesthesia information management system user interfaces: a usability evaluation.
Wanderer, Jonathan P; Rao, Anoop V; Rothwell, Sarah H; Ehrenfeld, Jesse M
2012-11-01
Anesthesia information management systems (AIMS) have been developed by multiple vendors and are deployed in thousands of operating rooms around the world, yet not much is known about measuring and improving AIMS usability. We developed a methodology for evaluating AIMS usability in a low-fidelity simulated clinical environment and used it to compare an existing user interface with a revised version. We hypothesized that the revised user interface would be more useable. In a low-fidelity simulated clinical environment, twenty anesthesia providers documented essential anesthetic information for the start of the case using both an existing and a revised user interface. Participants had not used the revised user interface previously and completed a brief training exercise prior to the study task. All participants completed a workload assessment and a satisfaction survey. All sessions were recorded. Multiple usability metrics were measured. The primary outcome was documentation accuracy. Secondary outcomes were perceived workload, number of documentation steps, number of user interactions, and documentation time. The interfaces were compared and design problems were identified by analyzing recorded sessions and survey results. Use of the revised user interface was shown to improve documentation accuracy from 85.1% to 92.4%, a difference of 7.3% (95% confidence interval [CI] for the difference 1.8 to 12.7). The revised user interface decreased the number of user interactions by 6.5 for intravenous documentation (95% CI 2.9 to 10.1) and by 16.1 for airway documentation (95% CI 11.1 to 21.1). The revised user interface required 3.8 fewer documentation steps (95% CI 2.3 to 5.4). Airway documentation time was reduced by 30.5 seconds with the revised workflow (95% CI 8.5 to 52.4). There were no significant time differences noted in intravenous documentation or in total task time. No difference in perceived workload was found between the user interfaces. Two user interface design problems were identified in the revised user interface. The usability of anesthesia information management systems can be evaluated using a low-fidelity simulated clinical environment. User testing of the revised user interface showed improvement in some usability metrics and highlighted areas for further revision. Vendors of AIMS and those who use them should consider adopting methods to evaluate and improve AIMS usability.
NASA Technical Reports Server (NTRS)
El-Sum, H. M. A.
1976-01-01
The international status of the art of acousto optical imaging techniques adaptable to nondestructive testing and, interfacing methods for acoustical and optical holography in nondestructive testing research are studied. Evaluation of 20 different techniques encompassed investigation of varieties of detectors and detection schemes, all of which are described and summarized. Related investigation is reported in an Appendix. Important remarks on image quality, factors to be considered in designing a particular system, and conclusions and recommendations are presented. Three bibliographies are included.
The Power of Why: Engaging the Goal Paradox in Program Evaluation
ERIC Educational Resources Information Center
Friedman, Victor J.; Rothman, Jay; Withers, Bill
2006-01-01
Clearly defined and measurable goals are commonly considered prerequisites for effective evaluation. Goal setting, however, presents a paradox to evaluators because it takes place at the interface of rationality and values. The objective of this article is to demonstrate a method for unlocking this paradox by making goal setting a process of…
bioLights: light emitting wear for visualizing lower-limb muscle activity.
Igarashi, Naoto; Suzuki, Kenji; Kawamoto, Hiroaki; Sankai, Yoshiyuki
2010-01-01
Analysis of muscle activity by electrophysiological techniques is commonly used to analyze biomechanics. Although the simultaneous and intuitive understanding of both muscle activity and body motion is important in various fields, it is difficult to realize. This paper proposes a novel technique for visualizing physiological signals related to muscle activity by means of surface electromyography. We developed a wearable light-emitting interface that indicates lower-limb muscle activity or muscular tension on the surface of the body in real time by displaying the shape of the activated muscle. The developed interface allows users to perceive muscle activity in an intuitive manner by relating the level of the muscle activity to the brightness level of the glowing interface placed on the corresponding muscle. In order to verify the advantage of the proposed method, a cognitive experiment was conducted to evaluate the system performance. We also conducted an evaluation experiment using the developed interface in conjunction with an exoskeleton robot, in order to investigate the possible applications of the developed interface in the field of neurorehabilitation.
On the Ionization and Ion Transmission Efficiencies of Different ESI-MS Interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, Jonathan T.; Marginean, Ioan; Smith, Richard D.
2014-09-30
It is well known that the achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. In this report we systematically study the ion transmission and ionization efficiencies in different ESI-MS interface configurations. The configurations under investigation include a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interfaces with a single emitter and an emitter array, respectively. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuringmore » the total gas phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Our experimental results suggest that the overall ion utilization efficiency in the SPIN-MS interface configurations is better than that in the inlet capillary based ESI-MS interface configurations.« less
Aeroelastic Analysis of Aircraft: Wing and Wing/Fuselage Configurations
NASA Technical Reports Server (NTRS)
Chen, H. H.; Chang, K. C.; Tzong, T.; Cebeci, T.
1997-01-01
A previously developed interface method for coupling aerodynamics and structures is used to evaluate the aeroelastic effects for an advanced transport wing at cruise and under-cruise conditions. The calculated results are compared with wind tunnel test data. The capability of the interface method is also investigated for an MD-90 wing/fuselage configuration. In addition, an aircraft trim analysis is described and applied to wing configurations. The accuracy of turbulence models based on the algebraic eddy viscosity formulation of Cebeci and Smith is studied for airfoil flows at low Mach numbers by using methods based on the solutions of the boundary-layer and Navier-Stokes equations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halligan, Matthew
Radiated power calculation approaches for practical scenarios of incomplete high- density interface characterization information and incomplete incident power information are presented. The suggested approaches build upon a method that characterizes power losses through the definition of power loss constant matrices. Potential radiated power estimates include using total power loss information, partial radiated power loss information, worst case analysis, and statistical bounding analysis. A method is also proposed to calculate radiated power when incident power information is not fully known for non-periodic signals at the interface. Incident data signals are modeled from a two-state Markov chain where bit state probabilities aremore » derived. The total spectrum for windowed signals is postulated as the superposition of spectra from individual pulses in a data sequence. Statistical bounding methods are proposed as a basis for the radiated power calculation due to the statistical calculation complexity to find a radiated power probability density function.« less
Zheng, Hua; Rosal, Milagros C; Li, Wenjun; Borg, Amy; Yang, Wenyun; Ayers, David C
2018-01-01
Background Data-driven surgical decisions will ensure proper use and timing of surgical care. We developed a Web-based patient-centered treatment decision and assessment tool to guide treatment decisions among patients with advanced knee osteoarthritis who are considering total knee replacement surgery. Objective The aim of this study was to examine user experience and acceptance of the Web-based treatment decision support tool among older adults. Methods User-centered formative and summative evaluations were conducted for the tool. A sample of 28 patients who were considering total knee replacement participated in the study. Participants’ responses to the user interface design, the clarity of information, as well as usefulness, satisfaction, and acceptance of the tool were collected through qualitative (ie, individual patient interviews) and quantitative (ie, standardized Computer System Usability Questionnaire) methods. Results Participants were older adults with a mean age of 63 (SD 11) years. Three-quarters of them had no technical questions using the tool. User interface design recommendations included larger fonts, bigger buttons, less colors, simpler navigation without extra “next page” click, less mouse movement, and clearer illustrations with simple graphs. Color-coded bar charts and outcome-specific graphs with positive action were easiest for them to understand the outcomes data. Questionnaire data revealed high satisfaction with the tool usefulness and interface quality, and also showed ease of use of the tool, regardless of age or educational status. Conclusions We evaluated the usability of a patient-centered decision support tool designed for advanced knee arthritis patients to facilitate their knee osteoarthritis treatment decision making. The lessons learned can inform other decision support tools to improve interface and content design for older patients’ use. PMID:29712620
Jelínek, Jan; Škoda, Petr; Hoksza, David
2017-12-06
Protein-protein interactions (PPI) play a key role in an investigation of various biochemical processes, and their identification is thus of great importance. Although computational prediction of which amino acids take part in a PPI has been an active field of research for some time, the quality of in-silico methods is still far from perfect. We have developed a novel prediction method called INSPiRE which benefits from a knowledge base built from data available in Protein Data Bank. All proteins involved in PPIs were converted into labeled graphs with nodes corresponding to amino acids and edges to pairs of neighboring amino acids. A structural neighborhood of each node was then encoded into a bit string and stored in the knowledge base. When predicting PPIs, INSPiRE labels amino acids of unknown proteins as interface or non-interface based on how often their structural neighborhood appears as interface or non-interface in the knowledge base. We evaluated INSPiRE's behavior with respect to different types and sizes of the structural neighborhood. Furthermore, we examined the suitability of several different features for labeling the nodes. Our evaluations showed that INSPiRE clearly outperforms existing methods with respect to Matthews correlation coefficient. In this paper we introduce a new knowledge-based method for identification of protein-protein interaction sites called INSPiRE. Its knowledge base utilizes structural patterns of known interaction sites in the Protein Data Bank which are then used for PPI prediction. Extensive experiments on several well-established datasets show that INSPiRE significantly surpasses existing PPI approaches.
Piloted Evaluation of the H-Mode, a Variable Autonomy Control System, in Motion-Based Simulation
NASA Technical Reports Server (NTRS)
Goodrich, Kenneth H.; Schutte, Paul C.; Williams, Ralph A.
2008-01-01
As aircraft become able to autonomously respond to a range of situations with performance surpassing human operators, we are compelled to look for new methods that help understand their use and guide the design of new, more effective forms of automation and interaction. The "H-mode" is one such method and is based on the metaphor of a well-trained horse. The concept allows the pilot to manage a broad range of control automation functionality, from augmented manual control to FMS-like coupling and automation initiated actions, using a common interface system and easily learned set of interaction skills. The interface leverages familiar manual control interfaces (e.g., the control stick) and flight displays through the addition of contextually dependent haptic-multimodal elements. The concept is relevant to manned and remotely piloted vehicles. This paper provides an overview of the H-mode concept followed by a presentation of the results from a recent evaluation conducted in a motion-based simulator. The evaluation focused on assessing the overall usability and flying qualities of the concept with an emphasis on the effects of turbulence and cockpit motion. Because the H-mode results in interactions between traditional flying qualities and management of higher-level flight path automation, these effects are of particular interest. The results indicate that the concept may provide a useful complement or replacement to conventional interfaces, and retains the usefulness in the presence of turbulence and motion.
NASA Astrophysics Data System (ADS)
Hoseini-Athar, M. M.; Tolaminejad, B.
2016-07-01
Explosive welding is a well-known solid state method for joining similar and dissimilar materials. In the present study, tri-layered Al-Cu-Al laminated composites with different interface morphologies were fabricated by explosive welding and subsequent rolling. Effects of explosive ratio and rolling thickness reduction on the morphology of interface and mechanical properties were evaluated through optical/scanning electron microscopy, micro-hardness, tensile and tensile-shear tests. Results showed that by increasing the thickness reduction, bonding strength of specimens including straight and wavy interfaces increases. However, bonding strength of the specimens with melted layer interface decreases up to a threshold thickness reduction, then rapidly increases by raising the reduction. Hardness Values of welded specimens were higher than those of original material especially near the interface and a more uniform hardness profile was obtained after rolling process.
Comparison of Sensor Selection Mechanisms for an ERP-Based Brain-Computer Interface
Metzen, Jan H.
2013-01-01
A major barrier for a broad applicability of brain-computer interfaces (BCIs) based on electroencephalography (EEG) is the large number of EEG sensor electrodes typically used. The necessity for this results from the fact that the relevant information for the BCI is often spread over the scalp in complex patterns that differ depending on subjects and application scenarios. Recently, a number of methods have been proposed to determine an individual optimal sensor selection. These methods have, however, rarely been compared against each other or against any type of baseline. In this paper, we review several selection approaches and propose one additional selection criterion based on the evaluation of the performance of a BCI system using a reduced set of sensors. We evaluate the methods in the context of a passive BCI system that is designed to detect a P300 event-related potential and compare the performance of the methods against randomly generated sensor constellations. For a realistic estimation of the reduced system's performance we transfer sensor constellations found on one experimental session to a different session for evaluation. We identified notable (and unanticipated) differences among the methods and could demonstrate that the best method in our setup is able to reduce the required number of sensors considerably. Though our application focuses on EEG data, all presented algorithms and evaluation schemes can be transferred to any binary classification task on sensor arrays. PMID:23844021
Multiphase Interface Tracking with Fast Semi-Lagrangian Contouring.
Li, Xiaosheng; He, Xiaowei; Liu, Xuehui; Zhang, Jian J; Liu, Baoquan; Wu, Enhua
2016-08-01
We propose a semi-Lagrangian method for multiphase interface tracking. In contrast to previous methods, our method maintains an explicit polygonal mesh, which is reconstructed from an unsigned distance function and an indicator function, to track the interface of arbitrary number of phases. The surface mesh is reconstructed at each step using an efficient multiphase polygonization procedure with precomputed stencils while the distance and indicator function are updated with an accurate semi-Lagrangian path tracing from the meshes of the last step. Furthermore, we provide an adaptive data structure, multiphase distance tree, to accelerate the updating of both the distance function and the indicator function. In addition, the adaptive structure also enables us to contour the distance tree accurately with simple bisection techniques. The major advantage of our method is that it can easily handle topological changes without ambiguities and preserve both the sharp features and the volume well. We will evaluate its efficiency, accuracy and robustness in the results part with several examples.
Guided wave propagation and spectral element method for debonding damage assessment in RC structures
NASA Astrophysics Data System (ADS)
Wang, Ying; Zhu, Xinqun; Hao, Hong; Ou, Jinping
2009-07-01
A concrete-steel interface spectral element is developed to study the guided wave propagation along the steel rebar in the concrete. Scalar damage parameters characterizing changes in the interface (debonding damage) are incorporated into the formulation of the spectral finite element that is used for damage detection of reinforced concrete structures. Experimental tests are carried out on a reinforced concrete beam with embedded piezoelectric elements to verify the performance of the proposed model and algorithm. Parametric studies are performed to evaluate the effect of different damage scenarios on wave propagation in the reinforced concrete structures. Numerical simulations and experimental results show that the method is effective to model wave propagation along the steel rebar in concrete and promising to detect damage in the concrete-steel interface.
Perception and Haptic Rendering of Friction Moments.
Kawasaki, H; Ohtuka, Y; Koide, S; Mouri, T
2011-01-01
This paper considers moments due to friction forces on the human fingertip. A computational technique called the friction moment arc method is presented. The method computes the static and/or dynamic friction moment independent of a friction force calculation. In addition, a new finger holder to display friction moment is presented. This device incorporates a small brushless motor and disk, and connects the human's finger to an interface finger of the five-fingered haptic interface robot HIRO II. Subjects' perception of friction moment while wearing the finger holder, as well as perceptions during object manipulation in a virtual reality environment, were evaluated experimentally.
A methodological approach for designing a usable ontology-based GUI in healthcare.
Lasierra, N; Kushniruk, A; Alesanco, A; Borycki, E; García, J
2013-01-01
This paper presents a methodological approach to the design and evaluation of an interface for an ontology-based system used for designing care plans for monitoring patients at home. In order to define the care plans, physicians need a tool for creating instances of the ontology and configuring some rules. Our purpose is to develop an interface to allow clinicians to interact with the ontology. Although ontology-driven applications do not necessarily present the ontology in the user interface, it is our hypothesis that showing selected parts of the ontology in a "usable" way could enhance clinician's understanding and make easier the definition of the care plans. Based on prototyping and iterative testing, this methodology combines visualization techniques and usability methods. Preliminary results obtained after a formative evaluation indicate the effectiveness of suggested combination.
NASA Technical Reports Server (NTRS)
Feedback, Daniel L.; Cibuzar, Branelle R.
2009-01-01
The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.
Energy Level Alignment at Aqueous GaN and ZnO Interfaces
NASA Astrophysics Data System (ADS)
Hybertsen, Mark S.; Kharche, Neerav; Muckerman, James T.
2014-03-01
Electronic energy level alignment at semiconductor-electrolyte interfaces is fundamental to electrochemical activity. Motivated in particular by the search for new materials that can be more efficient for photocatalysis, we develop a first principles method to calculate this alignment at aqueous interfaces and demonstrate it for the specific case of non-polar GaN and ZnO interfaces with water. In the first step, density functional theory (DFT) based molecular dynamics is used to sample the physical interface structure and to evaluate the electrostatic potential step at the interface. In the second step, the GW approach is used to evaluate the reference electronic energy level separately in the bulk semiconductor (valence band edge energy) and in bulk water (the 1b1 energy level), relative to the internal electrostatic energy reference. Use of the GW approach naturally corrects for errors inherent in the use of Kohn-Sham energy eigenvalues to approximate the electronic excitation energies in each material. With this predicted interface alignment, specific redox levels in water, with potentials known relative to the 1b1 level, can then be compared to the semiconductor band edge positions. Our results will be discussed in the context of experiments in which photoexcited GaN and ZnO drive the hydrogen evolution reaction. Research carried out at Brookhaven National Laboratory under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
ERIC Educational Resources Information Center
Stock, Steven E.; Davies, Daniel K.; Davies, Katelyn R.; Wehmeyer, Michael L.
2006-01-01
Background: Palmtop computers provide a promising mobile platform to address barriers to computer-based supports for people with intellectual disabilities. This study evaluated a specially designed interface to make navigation and features of palmtop computers more accessible to users with intellectual disabilities. Method: The specialised…
Jacob, Mithun George; Wachs, Juan Pablo; Packer, Rebecca A
2013-01-01
This paper presents a method to improve the navigation and manipulation of radiological images through a sterile hand gesture recognition interface based on attentional contextual cues. Computer vision algorithms were developed to extract intention and attention cues from the surgeon's behavior and combine them with sensory data from a commodity depth camera. The developed interface was tested in a usability experiment to assess the effectiveness of the new interface. An image navigation and manipulation task was performed, and the gesture recognition accuracy, false positives and task completion times were computed to evaluate system performance. Experimental results show that gesture interaction and surgeon behavior analysis can be used to accurately navigate, manipulate and access MRI images, and therefore this modality could replace the use of keyboard and mice-based interfaces. PMID:23250787
Jacob, Mithun George; Wachs, Juan Pablo; Packer, Rebecca A
2013-06-01
This paper presents a method to improve the navigation and manipulation of radiological images through a sterile hand gesture recognition interface based on attentional contextual cues. Computer vision algorithms were developed to extract intention and attention cues from the surgeon's behavior and combine them with sensory data from a commodity depth camera. The developed interface was tested in a usability experiment to assess the effectiveness of the new interface. An image navigation and manipulation task was performed, and the gesture recognition accuracy, false positives and task completion times were computed to evaluate system performance. Experimental results show that gesture interaction and surgeon behavior analysis can be used to accurately navigate, manipulate and access MRI images, and therefore this modality could replace the use of keyboard and mice-based interfaces.
Fatigue of the Resin-Enamel Bonded Interface and the Mechanisms of Failure
Yahyazadehfar, Mobin; Mutluay, Mustafa Murat; Majd, Hessam; Ryou, Heonjune; Arola, Dwayne
2013-01-01
The durability of adhesive bonds to enamel and dentin and the mechanisms of degradation caused by cyclic loading are important to the survival of composite restorations. In this study a novel method of evaluation was used to determine the strength of resin-enamel bonded interfaces under both static and cyclic loading, and to identify the mechanisms of failure. Specimens with twin interfaces of enamel bonded to commercial resin composite were loaded in monotonic and cyclic 4-point flexure to failure within a hydrated environment. Results for the resin-enamel interface were compared with those for the resin composite (control) and values reported for resin-dentin adhesive bonds. Under both modes of loading the strength of the resin-enamel interface was significantly (p≤0.0001) lower than that of the resin composite and the resin-dentin bonded interface. Fatigue failure of the interface occurred predominately by fracture of enamel, adjacent to the interface, and not due to adhesive failures. In the absence of water aging or acid production of biofilms, the durability of adhesive bonds to enamel is lower than that achieved in dentin bonding. PMID:23571321
Usability of a patient education and motivation tool using heuristic evaluation.
Joshi, Ashish; Arora, Mohit; Dai, Liwei; Price, Kathleen; Vizer, Lisa; Sears, Andrew
2009-11-06
Computer-mediated educational applications can provide a self-paced, interactive environment to deliver educational content to individuals about their health condition. These programs have been used to deliver health-related information about a variety of topics, including breast cancer screening, asthma management, and injury prevention. We have designed the Patient Education and Motivation Tool (PEMT), an interactive computer-based educational program based on behavioral, cognitive, and humanistic learning theories. The tool is designed to educate users and has three key components: screening, learning, and evaluation. The objective of this tutorial is to illustrate a heuristic evaluation using a computer-based patient education program (PEMT) as a case study. The aims were to improve the usability of PEMT through heuristic evaluation of the interface; to report the results of these usability evaluations; to make changes based on the findings of the usability experts; and to describe the benefits and limitations of applying usability evaluations to PEMT. PEMT was evaluated by three usability experts using Nielsen's usability heuristics while reviewing the interface to produce a list of heuristic violations with severity ratings. The violations were sorted by heuristic and ordered from most to least severe within each heuristic. A total of 127 violations were identified with a median severity of 3 (range 0 to 4 with 0 = no problem to 4 = catastrophic problem). Results showed 13 violations for visibility (median severity = 2), 38 violations for match between system and real world (median severity = 2), 6 violations for user control and freedom (median severity = 3), 34 violations for consistency and standards (median severity = 2), 11 violations for error severity (median severity = 3), 1 violation for recognition and control (median severity = 3), 7 violations for flexibility and efficiency (median severity = 2), 9 violations for aesthetic and minimalist design (median severity = 2), 4 violations for help users recognize, diagnose, and recover from errors (median severity = 3), and 4 violations for help and documentation (median severity = 4). We describe the heuristic evaluation method employed to assess the usability of PEMT, a method which uncovers heuristic violations in the interface design in a quick and efficient manner. Bringing together usability experts and health professionals to evaluate a computer-mediated patient education program can help to identify problems in a timely manner. This makes this method particularly well suited to the iterative design process when developing other computer-mediated health education programs. Heuristic evaluations provided a means to assess the user interface of PEMT.
Evaluating polymeric biomaterial–environment interfaces by Langmuir monolayer techniques
Schöne, Anne-Christin; Roch, Toralf; Schulz, Burkhard
2017-01-01
Polymeric biomaterials are of specific relevance in medical and pharmaceutical applications due to their wide range of tailorable properties and functionalities. The knowledge about interactions of biomaterials with their biological environment is of crucial importance for developing highly sophisticated medical devices. To achieve optimal in vivo performance, a description at the molecular level is required to gain better understanding about the surface of synthetic materials for tailoring their properties. This is still challenging and requires the comprehensive characterization of morphological structures, polymer chain arrangements and degradation behaviour. The review discusses selected aspects for evaluating polymeric biomaterial–environment interfaces by Langmuir monolayer methods as powerful techniques for studying interfacial properties, such as morphological and degradation processes. The combination of spectroscopic, microscopic and scattering methods with the Langmuir techniques adapted to polymers can substantially improve the understanding of their in vivo behaviour. PMID:28468918
NASA Astrophysics Data System (ADS)
Cheng, Jian; Yue, Huiqiang; Yu, Shengjiao; Liu, Tiegang
2018-06-01
In this paper, an adjoint-based high-order h-adaptive direct discontinuous Galerkin method is developed and analyzed for the two dimensional steady state compressible Navier-Stokes equations. Particular emphasis is devoted to the analysis of the adjoint consistency for three different direct discontinuous Galerkin discretizations: including the original direct discontinuous Galerkin method (DDG), the direct discontinuous Galerkin method with interface correction (DDG(IC)) and the symmetric direct discontinuous Galerkin method (SDDG). Theoretical analysis shows the extra interface correction term adopted in the DDG(IC) method and the SDDG method plays a key role in preserving the adjoint consistency. To be specific, for the model problem considered in this work, we prove that the original DDG method is not adjoint consistent, while the DDG(IC) method and the SDDG method can be adjoint consistent with appropriate treatment of boundary conditions and correct modifications towards the underlying output functionals. The performance of those three DDG methods is carefully investigated and evaluated through typical test cases. Based on the theoretical analysis, an adjoint-based h-adaptive DDG(IC) method is further developed and evaluated, numerical experiment shows its potential in the applications of adjoint-based adaptation for simulating compressible flows.
Calculation of skin-stiffener interface stresses in stiffened composite panels
NASA Technical Reports Server (NTRS)
Cohen, David; Hyer, Michael W.
1987-01-01
A method for computing the skin-stiffener interface stresses in stiffened composite panels is developed. Both geometrically linear and nonlinear analyses are considered. Particular attention is given to the flange termination region where stresses are expected to exhibit unbounded characteristics. The method is based on a finite-element analysis and an elasticity solution. The finite-element analysis is standard, while the elasticity solution is based on an eigenvalue expansion of the stress functions. The eigenvalue expansion is assumed to be valid in the local flange termination region and is coupled with the finite-element analysis using collocation of stresses on the local region boundaries. Accuracy and convergence of the local elasticity solution are assessed using a geometrically linear analysis. Using this analysis procedure, the influence of geometric nonlinearities and stiffener parameters on the skin-stiffener interface stresses is evaluated.
Laser Shockwave Technique For Characterization Of Nuclear Fuel Plate Interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
James A. Smith; Barry H. Rabin; Mathieu Perton
2012-07-01
The US National Nuclear Security Agency is tasked with minimizing the worldwide use of high-enriched uranium. One aspect of that effort is the conversion of research reactors to monolithic fuel plates of low-enriched uranium. The manufacturing process includes hot isostatic press bonding of an aluminum cladding to the fuel foil. The Laser Shockwave Technique (LST) is here evaluated for characterizing the interface strength of fuel plates using depleted Uranium/Mo foils. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves and is therefore well adapted to the quality assurance of this process.more » Preliminary results show a clear signature of well-bonded and debonded interfaces and the method is able to classify/rank the bond strength of fuel plates prepared under different HIP conditions.« less
Laser shockwave technique for characterization of nuclear fuel plate interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perton, M.; Levesque, D.; Monchalin, J.-P.
2013-01-25
The US National Nuclear Security Agency is tasked with minimizing the worldwide use of high-enriched uranium. One aspect of that effort is the conversion of research reactors to monolithic fuel plates of low-enriched uranium. The manufacturing process includes hot isostatic press bonding of an aluminum cladding to the fuel foil. The Laser Shockwave Technique (LST) is here evaluated for characterizing the interface strength of fuel plates using depleted Uranium/Mo foils. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves and is therefore well adapted to the quality assurance of this process.more » Preliminary results show a clear signature of well-bonded and debonded interfaces and the method is able to classify/rank the bond strength of fuel plates prepared under different HIP conditions.« less
Lobo-Prat, Joan; Nizamis, Kostas; Janssen, Mariska M H P; Keemink, Arvid Q L; Veltink, Peter H; Koopman, Bart F J M; Stienen, Arno H A
2017-07-12
Adults with Duchenne muscular dystrophy (DMD) can benefit from devices that actively support their arm function. A critical component of such devices is the control interface as it is responsible for the human-machine interaction. Our previous work indicated that surface electromyography (sEMG) and force-based control with active gravity and joint-stiffness compensation were feasible solutions for the support of elbow movements (one degree of freedom). In this paper, we extend the evaluation of sEMG- and force-based control interfaces to simultaneous and proportional control of planar arm movements (two degrees of freedom). Three men with DMD (18-23 years-old) with different levels of arm function (i.e. Brooke scores of 4, 5 and 6) performed a series of line-tracing tasks over a tabletop surface using an experimental active arm support. The arm movements were controlled using three control methods: sEMG-based control, force-based control with stiffness compensation (FSC), and force-based control with no compensation (FNC). The movement performance was evaluated in terms of percentage of task completion, tracing error, smoothness and speed. For subject S1 (Brooke 4) FNC was the preferred method and performed better than FSC and sEMG. FNC was not usable for subject S2 (Brooke 5) and S3 (Brooke 6). Subject S2 presented significantly lower movement speed with sEMG than with FSC, yet he preferred sEMG since FSC was perceived to be too fatiguing. Subject S3 could not successfully use neither of the two force-based control methods, while with sEMG he could reach almost his entire workspace. Movement performance and subjective preference of the three control methods differed with the level of arm function of the participants. Our results indicate that all three control methods have to be considered in real applications, as they present complementary advantages and disadvantages. The fact that the two weaker subjects (S2 and S3) experienced the force-based control interfaces as fatiguing suggests that sEMG-based control interfaces could be a better solution for adults with DMD. Yet force-based control interfaces can be a better alternative for those cases in which voluntary forces are higher than the stiffness forces of the arms.
van Engen-Verheul, Mariëtte M; Peute, Linda W P; de Keizer, Nicolette F; Peek, Niels; Jaspers, Monique W M
2016-03-01
Cumbersome electronic patient record (EPR) interfaces may complicate data-entry in clinical practice. Completeness of data entered in the EPR determines, among other things, the value of computerized clinical decision support (CCDS). Quantitative usability evaluations can provide insight into mismatches between the system design model of data entry and users' data entry behavior, but not into the underlying causes for these mismatches. Mixed method usability evaluation studies may provide these insights, and thus support generating redesign recommendations for improving an EPR system's data entry interface. To improve the usability of the data entry interface of an EPR system with CCDS in the field of cardiac rehabilitation (CR), and additionally, to assess the value of a mixed method usability approach in this context. Seven CR professionals performed a think-aloud usability evaluation both before (beta-version) and after the redesign of the system. Observed usability problems from both evaluations were analyzed and categorized using Zhang et al.'s heuristic principles of good interface design. We combined the think-aloud usability evaluation of the system's beta-version with the measurement of a new usability construct: users' deviations in action sequence from the system's predefined data entry order sequence. Recommendations for redesign were implemented. We assessed whether the redesign improved CR professionals' (1) task efficacy (with respect to the completeness of data they collected), and (2) task efficiency (with respect to the average number of mouse clicks they needed to complete data entry subtasks). With the system's beta version, 40% of health care professionals' navigation actions through the system deviated from the predefined next system action. The causes for these deviations as revealed by the think-aloud method mostly concerned mismatches between the system design model for data entry action sequences and users expectations of these action sequences, based on their paper-based daily routines. This caused non completion of data entry tasks (31% of main tasks completed), and more navigation actions than minimally required (146% of the minimum required). In the redesigned system the data entry navigational structure was organized in a flexible way around an overview screen to better mimic users' paper-based daily routines of collecting patient data. This redesign resulted in an increased number of completed main tasks (70%) and a decrease in navigation actions (133% of the minimum required). The think-aloud usability evaluation of the redesigned system showed that remaining problems concerned flexibility (e.g., lack of customization options) and consistency (mainly with layout and position of items on the screen). The mixed method usability evaluation was supportive in revealing the magnitude and causes of mismatches between the system design model of data-entry with users' data entry behavior. However, as both task efficacy and efficiency were still not optimal with the redesigned EPR, we advise to perform a cognitive analysis on end users' mental processes and behavior patterns in daily work processes specifically during the requirements analysis phase of development of interactive healthcare information systems. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
A level set method for determining critical curvatures for drainage and imbibition.
Prodanović, Masa; Bryant, Steven L
2006-12-15
An accurate description of the mechanics of pore level displacement of immiscible fluids could significantly improve the predictions from pore network models of capillary pressure-saturation curves, interfacial areas and relative permeability in real porous media. If we assume quasi-static displacement, at constant pressure and surface tension, pore scale interfaces are modeled as constant mean curvature surfaces, which are not easy to calculate. Moreover, the extremely irregular geometry of natural porous media makes it difficult to evaluate surface curvature values and corresponding geometric configurations of two fluids. Finally, accounting for the topological changes of the interface, such as splitting or merging, is nontrivial. We apply the level set method for tracking and propagating interfaces in order to robustly handle topological changes and to obtain geometrically correct interfaces. We describe a simple but robust model for determining critical curvatures for throat drainage and pore imbibition. The model is set up for quasi-static displacements but it nevertheless captures both reversible and irreversible behavior (Haines jump, pore body imbibition). The pore scale grain boundary conditions are extracted from model porous media and from imaged geometries in real rocks. The method gives quantitative agreement with measurements and with other theories and computational approaches.
El Saadawi, Gilan M.; Tseytlin, Eugene; Legowski, Elizabeth; Jukic, Drazen; Castine, Melissa; Fine, Jeffrey; Gormley, Robert; Crowley, Rebecca S.
2009-01-01
Introduction We developed and evaluated a Natural Language Interface (NLI) for an Intelligent Tutoring System (ITS) in Diagnostic Pathology. The system teaches residents to examine pathologic slides and write accurate pathology reports while providing immediate feedback on errors they make in their slide review and diagnostic reports. Residents can ask for help at any point in the case, and will receive context-specific feedback. Research Questions We evaluated (1) the performance of our natural language system, (2) the effect of the system on learning (3) the effect of feedback timing on learning gains and (4) the effect of ReportTutor on performance to self-assessment correlations. Methods The study uses a crossover 2×2 factorial design. We recruited 20 subjects from 4 academic programs. Subjects were randomly assigned to one of the four conditions - two conditions for the immediate interface, and two for the delayed interface. An expert dermatopathologist created a reference standard and 2 board certified AP/CP pathology fellows manually coded the residents' assessment reports. Subjects were given the opportunity to self grade their performance and we used a survey to determine student response to both interfaces. Results Our results show a highly significant improvement in report writing after one tutoring session with 4-fold increase in the learning gains with both interfaces but no effect of feedback timing on performance gains. Residents who used the immediate feedback interface first experienced a feature learning gain that is correlated with the number of cases they viewed. There was no correlation between performance and self-assessment in either condition. PMID:17934789
NASA Technical Reports Server (NTRS)
Jiang, Jian-Ping; Murphy, Elizabeth D.; Bailin, Sidney C.; Truszkowski, Walter F.
1993-01-01
Capturing human factors knowledge about the design of graphical user interfaces (GUI's) and applying this knowledge on-line are the primary objectives of the Computer-Human Interaction Models (CHIMES) project. The current CHIMES prototype is designed to check a GUI's compliance with industry-standard guidelines, general human factors guidelines, and human factors recommendations on color usage. Following the evaluation, CHIMES presents human factors feedback and advice to the GUI designer. The paper describes the approach to modeling human factors guidelines, the system architecture, a new method developed to convert quantitative RGB primaries into qualitative color representations, and the potential for integrating CHIMES with user interface management systems (UIMS). Both the conceptual approach and its implementation are discussed. This paper updates the presentation on CHIMES at the first International Symposium on Ground Data Systems for Spacecraft Control.
Neuhaus, Philipp; Doods, Justin; Dugas, Martin
2015-01-01
Automatic coding of medical terms is an important, but highly complicated and laborious task. To compare and evaluate different strategies a framework with a standardized web-interface was created. Two UMLS mapping strategies are compared to demonstrate the interface. The framework is a Java Spring application running on a Tomcat application server. It accepts different parameters and returns results in JSON format. To demonstrate the framework, a list of medical data items was mapped by two different methods: similarity search in a large table of terminology codes versus search in a manually curated repository. These mappings were reviewed by a specialist. The evaluation shows that the framework is flexible (due to standardized interfaces like HTTP and JSON), performant and reliable. Accuracy of automatically assigned codes is limited (up to 40%). Combining different semantic mappers into a standardized Web-API is feasible. This framework can be easily enhanced due to its modular design.
NASA Astrophysics Data System (ADS)
Chidambaram, Thenappan
III-V semiconductors are potential candidates to replace Si as a channel material in next generation CMOS integrated circuits owing to their superior carrier mobilities. Low density of states (DOS) and typically high interface and border trap densities (Dit) in high mobility group III-V semiconductors provide difficulties in quantification of Dit near the conduction band edge. The trap response above the threshold voltage of a MOSFET can be very fast, and conventional Dit extraction methods, based on capacitance/conductance response (CV methods) of MOS capacitors at frequencies <1MHz, cannot distinguish conducting and trapped carriers. In addition, the CV methods have to deal with high dispersion in the accumulation region that makes it a difficult task to measure the true oxide capacitance, Cox value. Another implication of these properties of III-V interfaces is an ambiguity of determination of electron density in the MOSFET channel. Traditional evaluation of carrier density by integration of the C-V curve, gives incorrect values for D it and mobility. Here we employ gated Hall method to quantify the D it spectrum at the high-K oxide/III-V semiconductor interface for buried and surface channel devices using Hall measurement and capacitance-voltage data. Determination of electron density directly from Hall measurements allows for obtaining true mobility values.
Mechanics of fiber reinforced materials
NASA Astrophysics Data System (ADS)
Sun, Huiyu
This dissertation is dedicated to mechanics of fiber reinforced materials and the woven reinforcement and composed of four parts of research: analytical characterization of the interfaces in laminated composites; micromechanics of braided composites; shear deformation, and Poisson's ratios of woven fabric reinforcements. A new approach to evaluate the mechanical characteristics of interfaces between composite laminae based on a modified laminate theory is proposed. By including an interface as a special lamina termed the "bonding-layer" in the analysis, the mechanical properties of the interfaces are obtained. A numerical illustration is given. For micro-mechanical properties of three-dimensionally braided composite materials, a new method via homogenization theory and incompatible multivariable FEM is developed. Results from the hybrid stress element approach compare more favorably with the experimental data than other existing numerical methods widely used. To evaluate the shearing properties for woven fabrics, a new mechanical model is proposed during the initial slip region. Analytical results show that this model provides better agreement with the experiments for both the initial shear modulus and the slipping angle than the existing models. Finally, another mechanical model for a woven fabric made of extensible yarns is employed to calculate the fabric Poisson's ratios. Theoretical results are compared with the available experimental data. A thorough examination on the influences of various mechanical properties of yarns and structural parameters of fabrics on the Poisson's ratios of a woven fabric is given at the end.
Gaenko, Alexander; DeFusco, Albert; Varganov, Sergey A.; ...
2014-10-20
This work presents a nonadiabatic molecular dynamics study of the nonradiative decay of photoexcited trans-azomethane, using the ab initio multiple spawning (AIMS) program that has been interfaced with the General Atomic and Molecular Electronic Structure System (GAMESS) quantum chemistry package for on-the-fly electronic structure evaluation. The interface strategy is discussed, and the capabilities of the combined programs are demonstrated with a nonadiabatic molecular dynamics study of the nonradiative decay of photoexcited trans-azomethane. Energies, gradients, and nonadiabatic coupling matrix elements were obtained with the state-averaged complete active space self-consistent field method, as implemented in GAMESS. The influence of initial vibrational excitationmore » on the outcome of the photoinduced isomerization is explored. Increased vibrational excitation in the CNNC torsional mode shortens the excited state lifetime. Depending on the degree of vibrational excitation, the excited state lifetime varies from ~60–200 fs. As a result, these short lifetimes are in agreement with time-resolved photoionization mass spectroscopy experiments.« less
Dynamics of emulsification and demulsification of water in crude oil emulsions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhardwaj, A.; Hartland, S.
1994-05-01
The effect of aging on the crude oil/water interface has been studied, and the slow buildup of natural surfactants present in the crude oil at the interface was observed. Interfacial tension data and microvideography were used to evaluate the buildup of surface concentration. The methodology adopted in this work permits the calculation of the actual surface excess of natural surfactants at the crude oil/water interface, without having to isolate them from the crude oil and without knowing their bulk molar concentration. The rate of adsorption of demulsifier at the interface was determined by measurement of the dynamic interfacial tension bymore » a microprocessor-controlled drop volume method apparatus. Temperature, concentration, and nature of the medium (crude oil or brine) were found to be very important parameters governing adsorption of demulsifier at the interface. Diffusion of the emulsifier to the oil/water interface was much slower when demulsifier was present in the oil phase than when it was present in the water phase.« less
Modelling and simulation of a moving interface problem: freeze drying of black tea extract
NASA Astrophysics Data System (ADS)
Aydin, Ebubekir Sıddık; Yucel, Ozgun; Sadikoglu, Hasan
2017-06-01
The moving interface separates the material that is subjected to the freeze drying process as dried and frozen. Therefore, the accurate modeling the moving interface reduces the process time and energy consumption by improving the heat and mass transfer predictions during the process. To describe the dynamic behavior of the drying stages of the freeze-drying, a case study of brewed black tea extract in storage trays including moving interface was modeled that the heat and mass transfer equations were solved using orthogonal collocation method based on Jacobian polynomial approximation. Transport parameters and physical properties describing the freeze drying of black tea extract were evaluated by fitting the experimental data using Levenberg-Marquardt algorithm. Experimental results showed good agreement with the theoretical predictions.
Usability Study of a Computer-Based Self-Management System for Older Adults with Chronic Diseases
Tao, Da
2012-01-01
Background Usability can influence patients’ acceptance and adoption of a health information technology. However, little research has been conducted to study the usability of a self-management health care system, especially one geared toward elderly patients. Objective This usability study evaluated a new computer-based self-management system interface for older adults with chronic diseases, using a paper prototype approach. Methods Fifty older adults with different chronic diseases participated. Two usability evaluation methods were involved: (1) a heuristics evaluation and (2) end-user testing with a think-aloud testing method, audio recording, videotaping, and interviewing. A set of usability metrics was employed to determine the overall system usability, including task incompletion rate, task completion time, frequency of error, frequency of help, satisfaction, perceived usefulness, and perceived ease of use. Interviews were used to elicit participants’ comments on the system design. The quantitative data were analyzed using descriptive statistics and the qualitative data were analyzed for content. Results The participants were able to perform the predesigned self-management tasks with the current system design and they expressed mostly positive responses about the perceived usability measures regarding the system interface. However, the heuristics evaluation, performance measures, and interviews revealed a number of usability problems related to system navigation, information search and interpretation, information presentation, and readability. Design recommendations for further system interface modifications were discussed. Conclusions This study verified the usability of the self-management system developed for older adults with chronic diseases. Also, we demonstrated that our usability evaluation approach could be used to quickly and effectively identify usability problems in a health care information system at an early stage of the system development process using a paper prototype. Conducting a usability evaluation is an essential step in system development to ensure that the system features match the users’ true needs, expectations, and characteristics, and also to minimize the likelihood of the users committing user errors and having difficulties using the system. PMID:23612015
Zonal PANS: evaluation of different treatments of the RANS-LES interface
NASA Astrophysics Data System (ADS)
Davidson, L.
2016-03-01
The partially Reynolds-averaged Navier-Stokes (PANS) model can be used to simulate turbulent flows either as RANS, large eddy simulation (LES) or DNS. Its main parameter is fk whose physical meaning is the ratio of the modelled to the total turbulent kinetic energy. In RANS fk = 1, in DNS fk = 0 and in LES fk takes values between 0 and 1. Three different ways of prescribing fk are evaluated for decaying grid turbulence and fully developed channel flow: fk = 0.4, fk = k3/2tot/ɛ and, from its definition, fk = k/ktot where ktot is the sum of the modelled, k, and resolved, kres, turbulent kinetic energy. It is found that the fk = 0.4 gives the best results. In Girimaji and Wallin, a method was proposed to include the effect of the gradient of fk. This approach is used at RANS- LES interface in the present study. Four different interface models are evaluated in fully developed channel flow and embedded LES of channel flow: in both cases, PANS is used as a zonal model with fk = 1 in the unsteady RANS (URANS) region and fk = 0.4 in the LES region. In fully developed channel flow, the RANS- LES interface is parallel to the wall (horizontal) and in embedded LES, it is parallel to the inlet (vertical). The importance of the location of the horizontal interface in fully developed channel flow is also investigated. It is found that the location - and the choice of the treatment at the interface - may be critical at low Reynolds number or if the interface is placed too close to the wall. The reason is that the modelled turbulent shear stress at the interface is large and hence the relative strength of the resolved turbulence is small. In RANS, the turbulent viscosity - and consequently also the modelled Reynolds shear stress - is only weakly dependent on Reynolds number. It is found in the present work that it also applies in the URANS region.
Leveraging Electronic Tablets for General Pediatric Care
McKee, S.; Dugan, T.M.; Downs, S.M.
2015-01-01
Summary Background We have previously shown that a scan-able paper based interface linked to a computerized clinical decision support system (CDSS) can effectively screen patients in pediatric waiting rooms and support the physician using evidence based care guidelines at the time of clinical encounter. However, the use of scan-able paper based interface has many inherent limitations including lacking real time communication with the CDSS and being prone to human and system errors. An electronic tablet based user interface can not only overcome these limitations, but may also support advanced functionality for clinical and research use. However, use of such devices for pediatric care is not well studied in clinical settings. Objective In this pilot study, we enhance our pediatric CDSS with an electronic tablet based user interface and evaluate it for usability as well as for changes in patient questionnaire completion rates. Methods Child Health Improvement through Computers Leveraging Electronic Tablets or CHICLET is an electronic tablet based user interface. It is developed to augment the existing scan-able paper interface to our CDSS. For the purposes of this study, we deployed CHICLET in one outpatient pediatric clinic. Usability factors for CHICLET were evaluated via caregiver and staff surveys. Results When compared to the scan-able paper based interface, we observed an 18% increase or 30% relative increase in question completion rates using CHICLET. This difference was statistically significant. Caregivers and staff survey results were positive for using CHICLET in clinical environment. Conclusions Electronic tablets are a viable interface for capturing patient self-report in pediatric waiting rooms. We further hypothesize that the use of electronic tablet based interfaces will drive advances in computerized clinical decision support and create opportunities for patient engagement. PMID:25848409
Hoang, Tuan; Tran, Dat; Huang, Xu
2013-01-01
Common Spatial Pattern (CSP) is a state-of-the-art method for feature extraction in Brain-Computer Interface (BCI) systems. However it is designed for 2-class BCI classification problems. Current extensions of this method to multiple classes based on subspace union and covariance matrix similarity do not provide a high performance. This paper presents a new approach to solving multi-class BCI classification problems by forming a subspace resembled from original subspaces and the proposed method for this approach is called Approximation-based Common Principal Component (ACPC). We perform experiments on Dataset 2a used in BCI Competition IV to evaluate the proposed method. This dataset was designed for motor imagery classification with 4 classes. Preliminary experiments show that the proposed ACPC feature extraction method when combining with Support Vector Machines outperforms CSP-based feature extraction methods on the experimental dataset.
Todoran, R; Todoran, D; Szakács, Zs
2016-01-05
In this work we propose optical luminescence measurements as a method to evaluate the kinetics of adsorption processes. Measurement of the intensity of the integral optical radiation obtained from the mineral-xanthate interface layer, stimulated with a monochromatic pulsating optical signal, as a function of time were made. The luminescence radiation was obtained from the thin interface layer formed at the separation surface between the sphalerite natural mineral and potassium ethyl xanthate solution, for different solution concentrations and pH-es at the constant industry standard temperature. This method enabled us to determine the time to achieve dynamic equilibrium in the formation of the interface layer of approximately 20min, gaining information on the adsorption kinetics in the case of xanthate on mineral surface and leading to the optimization of the industrial froth flotation process. Copyright © 2015 Elsevier B.V. All rights reserved.
CDROM User Interface Evaluation: The Appropriateness of GUIs.
ERIC Educational Resources Information Center
Bosch, Victoria Manglano; Hancock-Beaulieu, Micheline
1995-01-01
Assesses the appropriateness of GUIs (graphical user interfaces), more specifically Windows-based interfaces for CD-ROM. An evaluation model is described that was developed to carry out an expert evaluation of the interfaces of seven CD-ROM products. Results are discussed in light of HCI (human-computer interaction) usability criteria and design…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terezakis, Stephanie A., E-mail: stereza1@jhmi.edu; Harris, Kendra M.; Ford, Eric
Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface,more » (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement.« less
ERIC Educational Resources Information Center
Hert, Carol A.; Nilan, Michael S.
1991-01-01
Presents preliminary data that characterizes the relationship between what users say they are trying to accomplish when using an online public access catalog (OPAC) and their perceptions of what input to give the system. Human-machine interaction is discussed, and appropriate methods for evaluating information retrieval systems are considered. (18…
Rule based design of conceptual models for formative evaluation
NASA Technical Reports Server (NTRS)
Moore, Loretta A.; Chang, Kai; Hale, Joseph P.; Bester, Terri; Rix, Thomas; Wang, Yaowen
1994-01-01
A Human-Computer Interface (HCI) Prototyping Environment with embedded evaluation capability has been investigated. This environment will be valuable in developing and refining HCI standards and evaluating program/project interface development, especially Space Station Freedom on-board displays for payload operations. This environment, which allows for rapid prototyping and evaluation of graphical interfaces, includes the following four components: (1) a HCI development tool; (2) a low fidelity simulator development tool; (3) a dynamic, interactive interface between the HCI and the simulator; and (4) an embedded evaluator that evaluates the adequacy of a HCI based on a user's performance. The embedded evaluation tool collects data while the user is interacting with the system and evaluates the adequacy of an interface based on a user's performance. This paper describes the design of conceptual models for the embedded evaluation system using a rule-based approach.
Rule based design of conceptual models for formative evaluation
NASA Technical Reports Server (NTRS)
Moore, Loretta A.; Chang, Kai; Hale, Joseph P.; Bester, Terri; Rix, Thomas; Wang, Yaowen
1994-01-01
A Human-Computer Interface (HCI) Prototyping Environment with embedded evaluation capability has been investigated. This environment will be valuable in developing and refining HCI standards and evaluating program/project interface development, especially Space Station Freedom on-board displays for payload operations. This environment, which allows for rapid prototyping and evaluation of graphical interfaces, includes the following four components: (1) a HCI development tool, (2) a low fidelity simulator development tool, (3) a dynamic, interactive interface between the HCI and the simulator, and (4) an embedded evaluator that evaluates the adequacy of a HCI based on a user's performance. The embedded evaluation tool collects data while the user is interacting with the system and evaluates the adequacy of an interface based on a user's performance. This paper describes the design of conceptual models for the embedded evaluation system using a rule-based approach.
Mapping the Diagnosis Axis of an Interface Terminology to the NANDA International Taxonomy
Juvé Udina, Maria-Eulàlia; Gonzalez Samartino, Maribel; Matud Calvo, Cristina
2012-01-01
Background. Nursing terminologies are designed to support nursing practice but, as with any other clinical tool, they should be evaluated. Cross-mapping is a formal method for examining the validity of the existing controlled vocabularies. Objectives. The study aims to assess the inclusiveness and expressiveness of the nursing diagnosis axis of a newly implemented interface terminology by cross-mapping with the NANDA-I taxonomy. Design/Methods. The study applied a descriptive design, using a cross-sectional, bidirectional mapping strategy. The sample included 728 concepts from both vocabularies. Concept cross-mapping was carried out to identify one-to-one, negative, and hierarchical connections. The analysis was conducted using descriptive statistics. Results. Agreement of the raters' mapping achieved 97%. More than 60% of the nursing diagnosis concepts in the NANDA-I taxonomy were mapped to concepts in the diagnosis axis of the new interface terminology; 71.1% were reversely mapped. Conclusions. Main results for outcome measures suggest that the diagnosis axis of this interface terminology meets the validity criterion of cross-mapping when mapped from and to the NANDA-I taxonomy. PMID:22830046
Mapping the Diagnosis Axis of an Interface Terminology to the NANDA International Taxonomy.
Juvé Udina, Maria-Eulàlia; Gonzalez Samartino, Maribel; Matud Calvo, Cristina
2012-01-01
Background. Nursing terminologies are designed to support nursing practice but, as with any other clinical tool, they should be evaluated. Cross-mapping is a formal method for examining the validity of the existing controlled vocabularies. Objectives. The study aims to assess the inclusiveness and expressiveness of the nursing diagnosis axis of a newly implemented interface terminology by cross-mapping with the NANDA-I taxonomy. Design/Methods. The study applied a descriptive design, using a cross-sectional, bidirectional mapping strategy. The sample included 728 concepts from both vocabularies. Concept cross-mapping was carried out to identify one-to-one, negative, and hierarchical connections. The analysis was conducted using descriptive statistics. Results. Agreement of the raters' mapping achieved 97%. More than 60% of the nursing diagnosis concepts in the NANDA-I taxonomy were mapped to concepts in the diagnosis axis of the new interface terminology; 71.1% were reversely mapped. Conclusions. Main results for outcome measures suggest that the diagnosis axis of this interface terminology meets the validity criterion of cross-mapping when mapped from and to the NANDA-I taxonomy.
NASA Astrophysics Data System (ADS)
Negrutiu, Meda L.; Nica, Luminita; Sinescu, Cosmin; Topala, Florin; Ionita, Ciprian; Bradu, Adrian; Petrescu, Emanuela L.; Pop, Daniela M.; Rominu, Mihai; Podoleanu, Adrian Gh.
2011-03-01
Successful root canal treatment is based on diagnosis, treatment planning, knowledge of tooth anatomy, endodontic access cavity design, controlling the infection by thorough cleaning and shaping, methods and materials used in root canal obturation. An endodontic obturation must be a complete, three-dimensional filling of the root canal system, as close as possible to cemento-dentinal junction, without massive overfilling or underfilling. There are several known methods which are used to assess the quality of the endodontic sealing, but most are invasive. These lead to the destruction of the samples and often no conclusion could be drawn in respect to the existence of any microleakage in the investigated areas of interest. Using an time domain en-face OCT system, we have recently demonstrated real time thorough evaluation of quality of root canal fillings. The purpose of this in vitro study was to validate the en face OCT imagistic evaluation of endodontically treated human teeth by using scanning electron microscopy (SEM) and microcomputer tomography (μCT). SEM investigations evidenced the nonlinear aspect of the interface between the endodontic filling material and the root canal walls and materials defects in some samples. The results obtained by μCT revealed also some defects inside the root-canal filling and at the interfaces between the material and the root canal walls. The advantages of the OCT method consist in non-invasiveness and high resolution. In addition, en face OCT investigations permit visualization of the more complex stratified structure at the interface between the filling material and the dental hard tissue.
SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, J; Gueorguiev, G; Grassberger, C
2015-06-15
Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: Themore » water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.« less
Schindler, Christina E M; de Vries, Sjoerd J; Zacharias, Martin
2015-02-01
Protein-protein interactions are abundant in the cell but to date structural data for a large number of complexes is lacking. Computational docking methods can complement experiments by providing structural models of complexes based on structures of the individual partners. A major caveat for docking success is accounting for protein flexibility. Especially, interface residues undergo significant conformational changes upon binding. This limits the performance of docking methods that keep partner structures rigid or allow limited flexibility. A new docking refinement approach, iATTRACT, has been developed which combines simultaneous full interface flexibility and rigid body optimizations during docking energy minimization. It employs an atomistic molecular mechanics force field for intermolecular interface interactions and a structure-based force field for intramolecular contributions. The approach was systematically evaluated on a large protein-protein docking benchmark, starting from an enriched decoy set of rigidly docked protein-protein complexes deviating by up to 15 Å from the native structure at the interface. Large improvements in sampling and slight but significant improvements in scoring/discrimination of near native docking solutions were observed. Complexes with initial deviations at the interface of up to 5.5 Å were refined to significantly better agreement with the native structure. Improvements in the fraction of native contacts were especially favorable, yielding increases of up to 70%. © 2014 Wiley Periodicals, Inc.
Herasevich, Vitaly
2017-01-01
Background The new sepsis definition has increased the need for frequent sequential organ failure assessment (SOFA) score recalculation and the clerical burden of information retrieval makes this score ideal for automated calculation. Objective The aim of this study was to (1) estimate the clerical workload of manual SOFA score calculation through a time-motion analysis and (2) describe a user-centered design process for an electronic medical record (EMR) integrated, automated SOFA score calculator with subsequent usability evaluation study. Methods First, we performed a time-motion analysis by recording time-to-task-completion for the manual calculation of 35 baseline and 35 current SOFA scores by 14 internal medicine residents over a 2-month period. Next, we used an agile development process to create a user interface for a previously developed automated SOFA score calculator. The final user interface usability was evaluated by clinician end users with the Computer Systems Usability Questionnaire. Results The overall mean (standard deviation, SD) time-to-complete manual SOFA score calculation time was 61.6 s (33). Among the 24% (12/50) usability survey respondents, our user-centered user interface design process resulted in >75% favorability of survey items in the domains of system usability, information quality, and interface quality. Conclusions Early stakeholder engagement in our agile design process resulted in a user interface for an automated SOFA score calculator that reduced clinician workload and met clinicians’ needs at the point of care. Emerging interoperable platforms may facilitate dissemination of similarly useful clinical score calculators and decision support algorithms as “apps.” A user-centered design process and usability evaluation should be considered during creation of these tools. PMID:28526675
BCILAB: a platform for brain-computer interface development
NASA Astrophysics Data System (ADS)
Kothe, Christian Andreas; Makeig, Scott
2013-10-01
Objective. The past two decades have seen dramatic progress in our ability to model brain signals recorded by electroencephalography, functional near-infrared spectroscopy, etc., and to derive real-time estimates of user cognitive state, response, or intent for a variety of purposes: to restore communication by the severely disabled, to effect brain-actuated control and, more recently, to augment human-computer interaction. Continuing these advances, largely achieved through increases in computational power and methods, requires software tools to streamline the creation, testing, evaluation and deployment of new data analysis methods. Approach. Here we present BCILAB, an open-source MATLAB-based toolbox built to address the need for the development and testing of brain-computer interface (BCI) methods by providing an organized collection of over 100 pre-implemented methods and method variants, an easily extensible framework for the rapid prototyping of new methods, and a highly automated framework for systematic testing and evaluation of new implementations. Main results. To validate and illustrate the use of the framework, we present two sample analyses of publicly available data sets from recent BCI competitions and from a rapid serial visual presentation task. We demonstrate the straightforward use of BCILAB to obtain results compatible with the current BCI literature. Significance. The aim of the BCILAB toolbox is to provide the BCI community a powerful toolkit for methods research and evaluation, thereby helping to accelerate the pace of innovation in the field, while complementing the existing spectrum of tools for real-time BCI experimentation, deployment and use.
Perez, Liliana I; Echarri, Rodolfo M; Garea, María T; Santiago, Guillermo D
2011-03-01
This work shows that all first- and second-order nongeometric effects on propagation, total or partial reflection, and transmission can be understood and evaluated considering the superposition of two plane waves. It also shows that this description yields results that are qualitatively and quantitatively compatible with those obtained by Fourier analysis of beams with Gaussian intensity distribution in any type of interface. In order to show this equivalence, we start by describing the first- and second-order nongeometric effects, and we calculate them analytically by superposing two plane waves. Finally, these results are compared with those obtained for the nongeometric effects of Gaussian beams in isotropic interfaces and are applied to different types of interfaces. A simple analytical expression for the angular shift is obtained considering the transmission of an extraordinary beam in a uniaxial-isotropic interface.
NASA Astrophysics Data System (ADS)
Krautschneider, W.; Wagemann, H. G.
1983-10-01
Kuhn's quasi-static C(V)-method has been extended to MOS transistors by considering the capacitances of the source and drain p-n junctions additionally to the MOS varactor circuit model. The width of the space charge layers w(phi sub s) is calculated as a function of the surface potential phi sub s and applied to the MOS capacitance as a function of the gate voltage. Capacitance behavior for different channel length is presented as a model and compared to measurement results and evaluations of energetic distributions of interface states Dit(phi sub s) for MOS transistor and MOS varactor on the same chip.
Integrated Model for E-Learning Acceptance
NASA Astrophysics Data System (ADS)
Ramadiani; Rodziah, A.; Hasan, S. M.; Rusli, A.; Noraini, C.
2016-01-01
E-learning is not going to work if the system is not used in accordance with user needs. User Interface is very important to encourage using the application. Many theories had discuss about user interface usability evaluation and technology acceptance separately, actually why we do not make it correlation between interface usability evaluation and user acceptance to enhance e-learning process. Therefore, the evaluation model for e-learning interface acceptance is considered important to investigate. The aim of this study is to propose the integrated e-learning user interface acceptance evaluation model. This model was combined some theories of e-learning interface measurement such as, user learning style, usability evaluation, and the user benefit. We formulated in constructive questionnaires which were shared at 125 English Language School (ELS) students. This research statistics used Structural Equation Model using LISREL v8.80 and MANOVA analysis.
Ludwig, Simone A; Kong, Jun
2017-12-01
Innovative methods and new technologies have significantly improved the quality of our daily life. However, disabled people, for example those that cannot use their arms and legs anymore, often cannot benefit from these developments, since they cannot use their hands to interact with traditional interaction methods (such as mouse or keyboard) to communicate with a computer system. A brain-computer interface (BCI) system allows such a disabled person to control an external device via brain waves. Past research mostly dealt with static interfaces, which limit users to a stationary location. However, since we are living in a world that is highly mobile, this paper evaluates a speller interface on a mobile phone used in a moving condition. The spelling experiments were conducted with 14 able-bodied subjects using visual flashes as the stimulus to spell 47 alphanumeric characters (38 letters and 9 numbers). This data was then used for the classification experiments. In par- ticular, two research directions are pursued. The first investigates the impact of different classification algorithms, and the second direction looks at the channel configuration, i.e., which channels are most beneficial in terms of achieving the highest classification accuracy. The evaluation results indicate that the Bayesian Linear Discriminant Analysis algorithm achieves the best accuracy. Also, the findings of the investigation on the channel configuration, which can potentially reduce the amount of data processing on a mobile device with limited computing capacity, is especially useful in mobile BCIs.
NASA Astrophysics Data System (ADS)
Li, Y.; Han, B. C.; Gao, M.; Wan, Y. Z.; Yang, J.; Du, H. W.; Ma, Z. Q.
2017-09-01
On the basis of a photon-assisted high frequency capacitance-voltage (C-V) method (1 MHz C-V), an effective approach is developed to evaluate the average interface state density (Dit) of an ITO-SiOx/n-Si heterojunction structure. Tin-doped indium oxide (ITO) films with different thicknesses were directly deposited on (100) n-type crystalline silicon by magnetron sputtering to fabricate semiconductor-insulator-semiconductor (SIS) hetero-interface regions where an ultra-thin SiOx passivation layer was naturally created. The morphology of the SiOx layer was confirmed by X-ray photoelectron spectroscopy depth profiling and transmission electron microscope analysis. The thinness of this SiOx layer was the main reason for the SIS interface state density being more difficult to detect than that of a typical metal-oxide-semiconductor structure. A light was used for photon injection while measuring the C-V of the device, thus enabling the photon-assisted C-V measurement of the Dit. By quantifying decreases of the light-induced-voltage as a variation of the capacitance caused by parasitic charge at interface states the passivation quality within the interface of ITO-SiOx/n-Si could be reasonably evaluated. The average interface state density of these SIS devices was measured as 1.2-1.7 × 1011 eV-1 cm-2 and declined as the passivation layer was made thicker. The lifetime of the minority carriers, dark leakage current, and the other photovoltaic parameters of the devices were also used to determine the passivation.
Yan, Shi; Dai, Yong; Zhao, Putian; Liu, Weiling
2018-01-01
Steel-concrete composite structures are playing an increasingly important role in economic construction because of a series of advantages of great stiffness, good seismic performance, steel material saving, cost efficiency, convenient construction, etc. However, in service process, due to the long-term effects of environmental impacts and dynamic loading, interfaces of a composite structure might generate debonding cracks, relative slips or separations, and so on, lowering the composite effect of the composite structure. In this paper, the piezoceramics (PZT) are used as transducers to perform experiments on interface debonding slips and separations of composite beams, respectively, aimed at proposing an interface damage identification model and a relevant damage detection innovation method based on PZT wave technology. One part of various PZT patches was embedded in concrete as "smart aggregates," and another part of the PZT patches was pasted on the surface of the steel beam flange, forming a sensor array. A push-out test for four specimens was carried out and experimental results showed that, under the action of the external loading, the received signal amplitudes will increasingly decrease with increase of debonding slips along the interface. The proposed signal energy-based interface damage detection algorithm is highly efficient in surface state evaluations of composite beams.
NASA Astrophysics Data System (ADS)
Wang, Xiao; Zhang, Hongfeng; Shen, Zongbao; Li, Jianwen; Qian, Qing; Liu, Huixia
2016-11-01
A novel laser shock synchronous welding and forming method is introduced, which utilizes laser-induced shock waves to accelerate the flyer plate towards the base plate to achieve the joining of dissimilar metals and forming in a specific shape of mold. The samples were obtained with different laser energies and standoff distances. The surface morphology and roughness of the samples were greatly affected by the laser energy and standoff distances. Fittability was investigated to examine the forming accuracy. The results showed that the samples replicate the mold features well. Straight and wavy interfaces with un-bonded regions in the center were observed through metallographic analysis. Moreover, Energy Disperse Spectroscopy analysis was conducted on the welding interface, and the results indicated that a short-distance elemental diffusion emerged in the welding interface. The nanoindentation hardness of the welding regions was measured to evaluate the welding interface. In addition, the Smoothed Particle Hydrodynamics method was employed to simulate the welding and forming process. It was shown that different standoff distances significantly affected the size of the welding regions and interface waveform characteristics. The numerical analysis results indicated that the opposite shear stress direction and effective plastic strain above a certain threshold are essential to successfully obtain welding and forming workpiece.
Computer-Based Tools for Evaluating Graphical User Interfaces
NASA Technical Reports Server (NTRS)
Moore, Loretta A.
1997-01-01
The user interface is the component of a software system that connects two very complex system: humans and computers. Each of these two systems impose certain requirements on the final product. The user is the judge of the usability and utility of the system; the computer software and hardware are the tools with which the interface is constructed. Mistakes are sometimes made in designing and developing user interfaces because the designers and developers have limited knowledge about human performance (e.g., problem solving, decision making, planning, and reasoning). Even those trained in user interface design make mistakes because they are unable to address all of the known requirements and constraints on design. Evaluation of the user inter-face is therefore a critical phase of the user interface development process. Evaluation should not be considered the final phase of design; but it should be part of an iterative design cycle with the output of evaluation being feed back into design. The goal of this research was to develop a set of computer-based tools for objectively evaluating graphical user interfaces. The research was organized into three phases. The first phase resulted in the development of an embedded evaluation tool which evaluates the usability of a graphical user interface based on a user's performance. An expert system to assist in the design and evaluation of user interfaces based upon rules and guidelines was developed during the second phase. During the final phase of the research an automatic layout tool to be used in the initial design of graphical inter- faces was developed. The research was coordinated with NASA Marshall Space Flight Center's Mission Operations Laboratory's efforts in developing onboard payload display specifications for the Space Station.
Assessment of a human computer interface prototyping environment
NASA Technical Reports Server (NTRS)
Moore, Loretta A.
1993-01-01
A Human Computer Interface (HCI) prototyping environment with embedded evaluation capability has been successfully assessed which will be valuable in developing and refining HCI standards and evaluating program/project interface development, especially Space Station Freedom on-board displays for payload operations. The HCI prototyping environment is designed to include four components: (1) a HCI format development tool, (2) a test and evaluation simulator development tool, (3) a dynamic, interactive interface between the HCI prototype and simulator, and (4) an embedded evaluation capability to evaluate the adequacy of an HCI based on a user's performance.
Method for determining optimal supercell representation of interfaces
NASA Astrophysics Data System (ADS)
Stradi, Daniele; Jelver, Line; Smidstrup, Søren; Stokbro, Kurt
2017-05-01
The geometry and structure of an interface ultimately determines the behavior of devices at the nanoscale. We present a generic method to determine the possible lattice matches between two arbitrary surfaces and to calculate the strain of the corresponding matched interface. We apply this method to explore two relevant classes of interfaces for which accurate structural measurements of the interface are available: (i) the interface between pentacene crystals and the (1 1 1) surface of gold, and (ii) the interface between the semiconductor indium-arsenide and aluminum. For both systems, we demonstrate that the presented method predicts interface geometries in good agreement with those measured experimentally, which present nontrivial matching characteristics and would be difficult to guess without relying on automated structure-searching methods.
Keyboard and message evaluation for cockpit input to data link
DOT National Transportation Integrated Search
1971-11-01
The project reported-herein studied some methods for implementation of the man-machine interface of Digital Data Link for Air Traffic Control. An analysis of information transfer requirements indicated that a vocabulary or less than 200 words could y...
Fundamental electrode kinetics
NASA Technical Reports Server (NTRS)
Elder, J. P.
1968-01-01
Report presents the fundamentals of electrode kinetics and the methods used in evaluating the characteristic parameters of rapid-charge transfer processes at electrode-electrolyte interfaces. The concept of electrode kinetics is outlined, followed by the principles underlying the experimental techniques for the investigation of electrode kinetics.
NASA Astrophysics Data System (ADS)
Abid, Najmul; Mirkhalaf, Mohammad; Barthelat, Francois
2018-03-01
Natural materials such as nacre, collagen, and spider silk are composed of staggered stiff and strong inclusions in a softer matrix. This type of hybrid microstructure results in remarkable combinations of stiffness, strength, and toughness and it now inspires novel classes of high-performance composites. However, the analytical and numerical approaches used to predict and optimize the mechanics of staggered composites often neglect statistical variations and inhomogeneities, which may have significant impacts on modulus, strength, and toughness. Here we present an analysis of localization using small representative volume elements (RVEs) and large scale statistical volume elements (SVEs) based on the discrete element method (DEM). DEM is an efficient numerical method which enabled the evaluation of more than 10,000 microstructures in this study, each including about 5,000 inclusions. The models explore the combined effects of statistics, inclusion arrangement, and interface properties. We find that statistical variations have a negative effect on all properties, in particular on the ductility and energy absorption because randomness precipitates the localization of deformations. However, the results also show that the negative effects of random microstructures can be offset by interfaces with large strain at failure accompanied by strain hardening. More specifically, this quantitative study reveals an optimal range of interface properties where the interfaces are the most effective at delaying localization. These findings show how carefully designed interfaces in bioinspired staggered composites can offset the negative effects of microstructural randomness, which is inherent to most current fabrication methods.
Evaluating the effects of pinyon thinning treatments at a wildland urban interface
J. R. Matchett; Matthew Brooks; Anne Halford; Dale Johnson; Helen Smith
2010-01-01
This study evaluated the short-term effects of thinning methods for pinyon pine woodlands at two sites in the southwestern Great Basin. Both cut/pile/burn and mastication treatments were equally effective at reducing the target fuels which were mature, live pinyon trees. Application costs though differed substantially, with the cut/pile/burn technique being less...
ERIC Educational Resources Information Center
Karoulis, Athanasis; Demetriadis, Stavros; Pombortsis, Andreas
2006-01-01
This paper compares several interface evaluation methods applied in the case of a computer based learning (CBL) environment, during a longitudinal study performed in three European countries, Greece, Germany, and Holland, and within the framework of an EC funded Leonardo da Vinci program. The paper firstly considers the particularities of the CBL…
Joining Dental Ceramic Layers With Glass
Saied, MA; Lloyd, IK; Haller, WK; Lawn, BR
2011-01-01
Objective Test the hypothesis that glass-bonding of free-form veneer and core ceramic layers can produce robust interfaces, chemically durable and aesthetic in appearance and, above all, resistant to delamination. Methods Layers of independently produced porcelains (NobelRondo™ Press porcelain, Nobel BioCare AB and Sagkura Interaction porcelain, Elephant Dental) and matching alumina or zirconia core ceramics (Procera alumina, Nobel BioCare AB, BioZyram yttria stabilized tetragonal zirconia polycrystal, Cyrtina Dental) were joined with designed glasses, tailored to match thermal expansion coefficients of the components and free of toxic elements. Scanning electron microprobe analysis was used to characterize the chemistry of the joined interfaces, specifically to confirm interdiffusion of ions. Vickers indentations were used to drive controlled corner cracks into the glass interlayers to evaluate the toughness of the interfaces. Results The glass-bonded interfaces were found to have robust integrity relative to interfaces fused without glass, or those fused with a resin-based adhesive. Significance The structural integrity of the interfaces between porcelain veneers and alumina or zirconia cores is a critical factor in the longevity of all-ceramic dental crowns and fixed dental prostheses. PMID:21802131
Geophysical characterisation of the groundwater-surface water interface
NASA Astrophysics Data System (ADS)
McLachlan, P. J.; Chambers, J. E.; Uhlemann, S. S.; Binley, A.
2017-11-01
Interactions between groundwater (GW) and surface water (SW) have important implications for water quantity, water quality, and ecological health. The subsurface region proximal to SW bodies, the GW-SW interface, is crucial as it actively regulates the transfer of nutrients, contaminants, and water between GW systems and SW environments. However, geological, hydrological, and biogeochemical heterogeneity in the GW-SW interface makes it difficult to characterise with direct observations. Over the past two decades geophysics has been increasingly used to characterise spatial and temporal variability throughout the GW-SW interface. Geophysics is a powerful tool in evaluating structural heterogeneity, revealing zones of GW discharge, and monitoring hydrological processes. Geophysics should be used alongside traditional hydrological and biogeochemical methods to provide additional information about the subsurface. Further integration of commonly used geophysical techniques, and adoption of emerging techniques, has the potential to improve understanding of the properties and processes of the GW-SW interface, and ultimately the implications for water quality and environmental health.
Experimental setup for evaluating an adaptive user interface for teleoperation control
NASA Astrophysics Data System (ADS)
Wijayasinghe, Indika B.; Peetha, Srikanth; Abubakar, Shamsudeen; Saadatzi, Mohammad Nasser; Cremer, Sven; Popa, Dan O.
2017-05-01
A vital part of human interactions with a machine is the control interface, which single-handedly could define the user satisfaction and the efficiency of performing a task. This paper elaborates the implementation of an experimental setup to study an adaptive algorithm that can help the user better tele-operate the robot. The formulation of the adaptive interface and associate learning algorithms are general enough to apply when the mapping between the user controls and the robot actuators is complex and/or ambiguous. The method uses a genetic algorithm to find the optimal parameters that produce the input-output mapping for teleoperation control. In this paper, we describe the experimental setup and associated results that was used to validate the adaptive interface to a differential drive robot from two different input devices; a joystick, and a Myo gesture control armband. Results show that after the learning phase, the interface converges to an intuitive mapping that can help even inexperienced users drive the system to a goal location.
Cavity Adaptation of Water-Based Restoratives Placed as Liners under a Resin Composite
Gaintantzopoulou, Maria D.; Eliades, George
2017-01-01
Purpose. To investigate the cavity adaptation of mineral trioxide (ProRoot MTA/MT), tricalcium silicate (Biodentine/BD), and glass ionomer (Equia Fil/EF) cements used as liners and the interfacial integrity between those liners and a composite resin placed as the main restorative material. Materials and Methods. Standardized class I cavities (n: 8 per group) were prepared in upper premolars. Cavities were lined with a 1 mm thick layer of each of the tested materials and restored with Optibond FL adhesive and Herculite Precis composite resin. Cavity adaptation of the restorations was investigated by computerized X-ray microtomography. The regions of interest (ROI) were set at the cavity-liner (CL) interface and the liner-resin (LR) interface. The percentage void volume fraction (%VVF) in the ROI was calculated. The specimens were then sectioned and the interfaces were evaluated by reflection optical microscopy, to measure the % length (%LD) of the interfacial gaps. Selected samples were further evaluated by scanning electron microscopy. Statistical analysis was performed by two-way ANOVA and Student-Newman-Keuls multiple comparison test (a = 0.05). Results. MT showed significantly higher %VVF and %LD values in CL interfaces than BD and EF (p < 0.05). No significant differences were found among the materials for the same values at the LR interfaces. Conclusions. When used as a composite liner, ProRoot MTA showed inferior cavity adaptation at dentin/liner interface when compared to Biodentine and Equia Fil. PMID:28465685
Zhang, Yi; Monsen, Karen A; Adam, Terrence J; Pieczkiewicz, David S; Daman, Megan; Melton, Genevieve B
2011-01-01
Time and motion (T&M) studies provide an objective method to measure the expenditure of time by clinicians. While some instruments for T&M studies have been designed to evaluate health information technology (HIT), these instruments have not been designed for nursing workflow. We took an existing open source HIT T&M study application designed to evaluate physicians in the ambulatory setting and rationally adapted it through empiric observations to record nursing activities in the inpatient setting and linked this instrument to an existing interface terminology, the Omaha System. Nursing activities involved several dimensions and could include multiple activities occurring simultaneously, requiring significant instrument redesign. 94% of the activities from the study instrument mapped adequately to the Omaha System. T&M study instruments require customization in design optimize them for different environments, such as inpatient nursing, to enable optimal data collection. Interface terminologies show promise as a framework for recording and analyzing T&M study data. PMID:22195228
Effects of fluoride residue on thermal stability in Cu/porous low-k interconnects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kobayashi, Y.; Ozaki, S.; Nakamura, T.
2014-06-19
We have investigated the effects of fluoride residue on the thermal stability of a Cu/barrier metal (BM)/porous low-k film (k < 2.3) structure. We confirmed that the Cu agglomerated more on a BM/inter layer dielectric (ILD) with a fluoride residue. To consider the effect of fluoride residue on Cu agglomeration, the structural state at the Cu/BM interface was evaluated with a cross-section transmission electron microscope (TEM) and atomic force microscope (AFM). In addition, the chemical bonding state at the Cu/BM interface was evaluated with the interface peeling-off method and X-ray photoelectron spectroscopy (XPS). Moreover, we confirmed the ionization of fluoridemore » residue and oxidation of Cu with fluoride and moisture to clarify the effect of fluoride residue on Cu. Our experimental results indicated that the thermal stability in Cu/porous low-k interconnects was degraded by enhancement of Cu oxidation with fluoride ions diffusion as an oxidizing catalyst.« less
Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant
Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon
2016-01-01
PURPOSE The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 106 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment. PMID:28018564
New methodology for evaluating osteoclastic activity induced by orthodontic load
ARAÚJO, Adriele Silveira; FERNANDES, Alline Birra Nolasco; MACIEL, José Vinicius Bolognesi; NETTO, Juliana de Noronha Santos; BOLOGNESE, Ana Maria
2015-01-01
Orthodontic tooth movement (OTM) is a dynamic process of bone modeling involving osteoclast-driven resorption on the compression side. Consequently, to estimate the influence of various situations on tooth movement, experimental studies need to analyze this cell. Objectives The aim of this study was to test and validate a new method for evaluating osteoclastic activity stimulated by mechanical loading based on the fractal analysis of the periodontal ligament (PDL)-bone interface. Material and Methods The mandibular right first molars of 14 rabbits were tipped mesially by a coil spring exerting a constant force of 85 cN. To evaluate the actual influence of osteoclasts on fractal dimension of bone surface, alendronate (3 mg/Kg) was injected weekly in seven of those rabbits. After 21 days, the animals were killed and their jaws were processed for histological evaluation. Osteoclast counts and fractal analysis (by the box counting method) of the PDL-bone interface were performed in histological sections of the right and left sides of the mandible. Results An increase in the number of osteoclasts and in fractal dimension after OTM only happened when alendronate was not administered. Strong correlation was found between the number of osteoclasts and fractal dimension. Conclusions Our results suggest that osteoclastic activity leads to an increase in bone surface irregularity, which can be quantified by its fractal dimension. This makes fractal analysis by the box counting method a potential tool for the assessment of osteoclastic activity on bone surfaces in microscopic examination. PMID:25760264
Development of a simulated smart pump interface.
Elias, Beth L; Moss, Jacqueline A; Shih, Alan; Dillavou, Marcus
2014-01-01
Medical device user interfaces are increasingly complex, resulting in a need for evaluation in clinicallyaccurate settings. Simulation of these interfaces can allow for evaluation, training, and use for research without the risk of harming patients and with a significant cost reduction over using the actual medical devices. This pilot project was phase 1 of a study to define and evaluate a methodology for development of simulated medical device interface technology to be used for education, device development, and research. Digital video and audio recordings of interface interactions were analyzed to develop a model of a smart intravenous medication infusion pump user interface. This model was used to program a high-fidelity simulated smart intravenous medication infusion pump user interface on an inexpensive netbook platform.
Scaled-Up Production and Transport Applications of Graphitic Carbon Nanomaterials
NASA Astrophysics Data System (ADS)
Saviers, Kimberly R.
Graphitic carbon nanomaterials enhance the performance of engineered systems for energy harvesting and storage. However, commercial availability remains largely cost-prohibitive due to technical barriers to mass production. This thesis examines both the scaled-up production and energy transport applications of graphitic materials. Cost driven-production of graphitic petals is developed, carbon nanotube array thermal interface materials enhance waste heat energy harvesting, and microsupercapacitors are visually examined using a new electroreflectance measurement method. Graphitic materials have previously been synthesized using batch-style processing methods with small sample sizes, limiting their commercial viability. In order to increase production throughput, a roll-to-roll radio-frequency plasma chemical vapor deposition method is employed to continuously deposit graphitic petals on carbon fiber tow. In consideration of a full production framework, efficient and informative characterization methods in the form of electrical resistance and electrochemical capacitance are highlighted. To co-optimize the functional characteristics of the material, the processing conditions are comprehensively varied using a data-driven predictive design of experiments method. Repeatable and reliable production of graphitic materials will enable a host of creative graphene-based devices to emerge into the marketplace. Two such applications are discussed in the remaining chapters. Waste heat is most efficiently harvested at high temperatures, such as vehicle exhaust systems near 600°C. However, the resistance to heat flux at the interfaces between the harvesting device and its surroundings is detrimental to the system-level performance. To study the performance of thermal interface materials up to 700°C, a reference bar measurement method was designed. Design considerations are discussed and compared to past implementations, particularly regarding radiation heat flux and thermal expansion at these elevated temperatures. The microscale roughness of the contacting measurement surface is fully characterized, as it fundamentally affects the resulting thermal interface resistance. This comprehensive method for determining thermal interface resistance at high temperatures includes the physical equipment, data acquisition system, and data analysis method. Thermomechanical evaluation of carbon nanotube arrays up to 700°C has shown that the arrays provide mechanical flexibility to accommodate thermal expansion in a thermomechanically mismatched interface. To demonstrate the application of the arrays for improving energy generation, they were evaluated in conjunction with a thermoelectric module. The system-level efficiency increases significantly when a carbon nanotube array is applied to the hot side of the thermoelectric module. Additional materials characterization suggests the presence of a strong thermal connection between the carbon nanotubes and their catalyst layers, due to covalent bonding between them. In another application of harvesting waste heat, the carbon nanotube arrays increase the performance of a thermo-magnetically actuated shuttle device for solar photovoltaic cells due to decreased thermal interface resistance. Vertically-oriented graphitic petals have previously enhanced supercapacitor power density. Here, a spatiotemporal characterization method is developed and utilized to study ageing phenomena in microsupercapacitor electrodes. The electroreflectance method captures images of charge accumulation in the electrodes at varying states during each charge-discharge cycle. The method was exploited by imaging each an ideal device and a device with defects over an extended period of over four million cycles. The charge accumulation patterns over the ageing period relate to the physical transport behavior. During a single discharge cycle, one may visually observe the electrons drifting out of the electrode. Overall, the investigations herein determine the following. Continuous production of graphitic petals is possible and is optimized by considering the effect of plasma conditions on the resulting functional performance of the material. Thermal interface resistance may be measured at high temperatures in order to understand the viability of interface materials for energy harvesting applications. Carbon nanotube array thermal interface materials lead to increased energy generation from thermoelectric modules. Spatial electroreflectance measurements of microsupercapacitors lead to observation of decreased physical wetting between the electrode and electrolyte, impacting device performance. Looking forward, creative application of graphitic carbon nanomaterials, coupled with cost-driven production capability, will launch them into the commercial marketplace.
Weis, Adam J.; Huxlin, Krystel R.; Callan, Christine L.; DeMagistris, Margaret A.; Hindman, Holly B.
2013-01-01
Purpose To evaluate myofibroblast differentiation as an etiology of haze at the graft-host interface in a cat model of Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK). Methods DSAEK was performed on 10 eyes of 5 adult domestic short-hair cats. In vivo corneal imaging with slit lamp, confocal, and optical coherence tomography (OCT) were performed twice weekly. Cats were sacrificed and corneas harvested 4 hours, and 2, 4, 6, and 9 days post-DSAEK. Corneal sections were stained with the TUNEL method and immunohistochemistry was performed for α-smooth muscle actin (α-SMA) and fibronectin with DAPI counterstain. Results At all in vivo imaging time-points, corneal OCT revealed an increase in backscatter of light and confocal imaging revealed an acellular zone at the graft-host interface. At all post-mortem time-points, immunohistochemistry revealed a complete absence of α-SMA staining at the graft-host interface. At 4 hours, extracellular fibronectin staining was identified along the graft-host interface and both fibronectin and TUNEL assay were positive within adjacent cells extending into the host stroma. By day 2, fibronectin and TUNEL staining diminished and a distinct acellular zone was present in the region of previously TUNEL-positive cells. Conclusions OCT imaging consistently showed increased reflectivity at the graft-host interface in cat corneas in the days post-DSAEK. This was not associated with myofibroblast differentiation at the graft-host interface, but rather with apoptosis and the development of a subsequent acellular zone. The roles of extracellular matrix changes and keratocyte cell death and repopulation should be investigated further as potential contributors to the interface optical changes. PMID:24098706
Multiple network interface core apparatus and method
Underwood, Keith D [Albuquerque, NM; Hemmert, Karl Scott [Albuquerque, NM
2011-04-26
A network interface controller and network interface control method comprising providing a single integrated circuit as a network interface controller and employing a plurality of network interface cores on the single integrated circuit.
Heuristic evaluation of eNote: an electronic notes system.
Bright, Tiffani J; Bakken, Suzanne; Johnson, Stephen B
2006-01-01
eNote is an electronic health record (EHR) system based on semi-structured narrative documents. A heuristic evaluation was conducted with a sample of five usability experts. eNote performed highly in: 1)consistency with standards and 2)recognition rather than recall. eNote needs improvement in: 1)help and documentation, 2)aesthetic and minimalist design, 3)error prevention, 4)helping users recognize, diagnosis, and recover from errors, and 5)flexibility and efficiency of use. The heuristic evaluation was an efficient method of evaluating our interface.
Charting the energy landscape of metal/organic interfaces via machine learning
NASA Astrophysics Data System (ADS)
Scherbela, Michael; Hörmann, Lukas; Jeindl, Andreas; Obersteiner, Veronika; Hofmann, Oliver T.
2018-04-01
The rich polymorphism exhibited by inorganic/organic interfaces is a major challenge for materials design. In this work, we present a method to efficiently explore the potential energy surface and predict the formation energies of polymorphs and defects. This is achieved by training a machine learning model on a list of only 100 candidate structures that are evaluated via dispersion-corrected density functional theory (DFT) calculations. We demonstrate the power of this approach for tetracyanoethylene on Ag(100) and explain the anisotropic ordering that is observed experimentally.
Charting the energy landscape of metal/organic interfaces via machine learning
Scherbela, Michael; Hormann, Lukas; Jeindl, Andreas; ...
2018-04-17
The rich polymorphism exhibited by inorganic/organic interfaces is a major challenge for materials design. Here in this work, we present a method to efficiently explore the potential energy surface and predict the formation energies of polymorphs and defects. This is achieved by training a machine learning model on a list of only 100 candidate structures that are evaluated via dispersion-corrected density functional theory (DFT) calculations. Finally, we demonstrate the power of this approach for tetracyanoethylene on Ag(100) and explain the anisotropic ordering that is observed experimentally.
Charting the energy landscape of metal/organic interfaces via machine learning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scherbela, Michael; Hormann, Lukas; Jeindl, Andreas
The rich polymorphism exhibited by inorganic/organic interfaces is a major challenge for materials design. Here in this work, we present a method to efficiently explore the potential energy surface and predict the formation energies of polymorphs and defects. This is achieved by training a machine learning model on a list of only 100 candidate structures that are evaluated via dispersion-corrected density functional theory (DFT) calculations. Finally, we demonstrate the power of this approach for tetracyanoethylene on Ag(100) and explain the anisotropic ordering that is observed experimentally.
Park, Jinwoo; Kumar, Vipin; Wang, Xu; Lee, Pooi See; Kim, Woong
2017-10-04
The redox-active electrolyte supercapacitor (RAES) is a relatively new type of energy storage device. Simple addition of selected redox species in the electrolyte can greatly enhance the energy density of supercapacitors relative to traditional electric double layer capacitors (EDLCs) owing to redox reactions. Studies on the kinetics at the interface of the electrode and redox mediator are important when developing RAESs. In this work, we employ highly accurate scanning electrochemical microscopy (SECM) to extract the kinetic constants at carbon/hydroquinone interfaces. The charge transfer rate constants are 1.2 × 10 -2 and 1.3 × 10 -2 cm s -1 for the carbon nanotube/hydroquinone and reduced graphene oxide/hydroquinone interfaces, respectively. These values are higher than those obtained by the conventional cyclic voltammetry method, approximately by an order of magnitude. The evaluation of heterogeneous rate constants with SECM would be the cornerstone for understanding and developing high performance RAESs.
Using the High-Level Based Program Interface to Facilitate the Large Scale Scientific Computing
Shang, Yizi; Shang, Ling; Gao, Chuanchang; Lu, Guiming; Ye, Yuntao; Jia, Dongdong
2014-01-01
This paper is to make further research on facilitating the large-scale scientific computing on the grid and the desktop grid platform. The related issues include the programming method, the overhead of the high-level program interface based middleware, and the data anticipate migration. The block based Gauss Jordan algorithm as a real example of large-scale scientific computing is used to evaluate those issues presented above. The results show that the high-level based program interface makes the complex scientific applications on large-scale scientific platform easier, though a little overhead is unavoidable. Also, the data anticipation migration mechanism can improve the efficiency of the platform which needs to process big data based scientific applications. PMID:24574931
In vitro evaluation of an alternative method to bond molar tubes
PINZAN-VERCELINO, Célia Regina Maio; PINZAN, Arnaldo; GURGEL, Júlio de Araújo; BRAMANTE, Fausto Silva; PINZAN, Luciana Maio
2011-01-01
Despite the advances in bonding materials, many clinicians today still prefer to place bands on molar teeth. Molar bonding procedures need improvement to be widely accepted clinically. Objective The purpose of this study was to evaluate the shear bond strength when an additional adhesive layer was applied on the occlusal tooth/tube interface to provide reinforcement to molar tubes. Material and methods Sixty third molars were selected and allocated to the 3 groups: group 1 received a conventional direct bond followed by the application of an additional layer of adhesive on the occlusal tooth/tube interface, group 2 received a conventional direct bond, and group 3 received a conventional direct bond and an additional cure time of 10 s. The specimens were debonded in a universal testing machine. The results were analyzed statistically by ANOVA and Tukey’s test (α=0.05). Results Group 1 had a significantly higher (p<0.05) shear bond strength compared to groups 2 and 3. No difference was detected between groups 2 and 3 (p>0.05). Conclusions The present in vitro findings indicate that the application of an additional layer of adhesive on the tooth/tube interface increased the shear bond strength of the bonded molar tubes. PMID:21437468
NASA Astrophysics Data System (ADS)
Le, Son Phuong; Nguyen, Duong Dai; Suzuki, Toshi-kazu
2018-01-01
We have investigated insulator-semiconductor interface fixed charges in AlGaN/GaN metal-insulator-semiconductor (MIS) devices with Al2O3 or AlTiO (an alloy of Al2O3 and TiO2) gate dielectrics obtained by atomic layer deposition on AlGaN. Analyzing insulator-thickness dependences of threshold voltages for the MIS devices, we evaluated positive interface fixed charges, whose density at the AlTiO/AlGaN interface is significantly lower than that at the Al2O3/AlGaN interface. This and a higher dielectric constant of AlTiO lead to rather shallower threshold voltages for the AlTiO gate dielectric than for Al2O3. The lower interface fixed charge density also leads to the fact that the two-dimensional electron concentration is a decreasing function of the insulator thickness for AlTiO, whereas being an increasing function for Al2O3. Moreover, we discuss the relationship between the interface fixed charges and interface states. From the conductance method, it is shown that the interface state densities are very similar at the Al2O3/AlGaN and AlTiO/AlGaN interfaces. Therefore, we consider that the lower AlTiO/AlGaN interface fixed charge density is not owing to electrons trapped at deep interface states compensating the positive fixed charges and can be attributed to a lower density of oxygen-related interface donors.
Initial constructs for patient-centered outcome measures to evaluate brain-computer interfaces.
Andresen, Elena M; Fried-Oken, Melanie; Peters, Betts; Patrick, Donald L
2016-10-01
The authors describe preliminary work toward the creation of patient-centered outcome (PCO) measures to evaluate brain-computer interface (BCI) as an assistive technology (AT) for individuals with severe speech and physical impairments (SSPI). In Phase 1, 591 items from 15 existing measures were mapped to the International Classification of Functioning, Disability and Health (ICF). In Phase 2, qualitative interviews were conducted with eight people with SSPI and seven caregivers. Resulting text data were coded in an iterative analysis. Most items (79%) were mapped to the ICF environmental domain; over half (53%) were mapped to more than one domain. The ICF framework was well suited for mapping items related to body functions and structures, but less so for items in other areas, including personal factors. Two constructs emerged from qualitative data: quality of life (QOL) and AT. Component domains and themes were identified for each. Preliminary constructs, domains and themes were generated for future PCO measures relevant to BCI. Existing instruments are sufficient for initial items but do not adequately match the values of people with SSPI and their caregivers. Field methods for interviewing people with SSPI were successful, and support the inclusion of these individuals in PCO research. Implications for Rehabilitation Adapted interview methods allow people with severe speech and physical impairments to participate in patient-centered outcomes research. Patient-centered outcome measures are needed to evaluate the clinical implementation of brain-computer interface as an assistive technology.
Akl, Elie A; Mustafa, Reem; Slomka, Thomas; Alawneh, Alia; Vedavalli, Abhishek; Schünemann, Holger J
2008-01-01
Background Adherence to Clinical Practice Guidelines (CPGs) remains suboptimal among internal medicine trainees. Educational games are of growing interest and have the potential to improve adherence to CPGs. The objectives of this study were to develop an educational game to teach CPGs in Internal Medicine residency programs and to evaluate its feasibility and acceptability. Methods We developed the Guide-O-Game© in the format of a TV game show with questions based on recommendations of CPGs. The development of the Guide-O-Game© consisted of the creation of a multimedia interactive tool, the development of recommendation-based questions, and the definition of the game's rules. We evaluated its feasibility through pilot testing and its acceptability through a qualitative process. Results The multimedia interactive tool uses a Macromedia Flash web application and consists of a manager interface and a user interface. The user interface allows the choice of two game styles. We created so far 16 sets of questions relating to 9 CPGs. The pilot testing proved that the game was feasible. The qualitative evaluation showed that residents considered the game to be acceptable. Conclusion We developed an educational game to teach CPGs to Internal Medicine residents that is both feasible and acceptable. Future work should evaluate its impact on educational outcomes. PMID:19017400
Piattelli, Adriano
2017-01-01
Background Direct metal laser sintering (DMLS) is an additive manufacturing technique that allows the fabrication of dental implants layer by layer through the laser fusion of titanium microparticles. The surface of DMLS implants is characterized by a high open porosity with interconnected pores of different sizes; therefore, it has the potential to enhance and accelerate bone healing. To date, however, there are no histologic/histomorphometric studies in the literature evaluating the interface between bone and DMLS implants in the long-term. Purpose To evaluate the interface between bone and DMLS implants retrieved after 5 years of functional loading. Methods Two fractured DMLS implants were retrieved from the human jaws, using a 5 mm trephine bur. Both the implants were clinically stable and functioned regularly before fracture. The specimens were processed for histologic/histomorphometric evaluation; the bone-to-implant contact (BIC%) was calculated. Results Compact, mature lamellar bone was found over most of the DMLS implants in close contact with the implant surface; the histomorphometric evaluation showed a mean BIC% of 66.1% (±4.5%). Conclusions The present histologic/histomorphometric study showed that DMLS implants were well integrated in bone, after 5 years of loading, with the peri-implant bone undergoing continuous remodeling at the interface. PMID:28929117
Usability in the real world: assessing medical information technologies in patients' homes.
Kaufman, David R; Patel, Vimla L; Hilliman, Charlyn; Morin, Philip C; Pevzner, Jenia; Weinstock, Ruth S; Goland, Robin; Shea, Steven; Starren, Justin
2003-01-01
This paper presents an approach to usability evaluation of computer-based health care systems designed for patient use in their homes. Although such devices are becoming more prevalent, there is very little known about their usability. The theoretical foundations for the methods are discussed. The approach incorporates a cognitive walkthrough usability evaluation and new methods for usability testing that can be conducted in patient's homes. The method was applied to the IDEATel intervention, a multi-institution randomized controlled trial of the feasibility, acceptability, and clinical utility of a home-based telemedicine system for diabetic Medicare population. The usability study was designed to assess barriers to optimal use of the system. The focus was both on dimensions of the interface and on dimensions of patient skills and competency. The usability field research involved testing 25 patients in their homes using the system. The analysis included a range of video-analytic methods of varying levels of granularity. The usability evaluation revealed aspects of the interface that were sub-optimal and impeded the performance of certain tasks. It also found a range of patient-related factors such as numeracy and psychomotor skills that constituted barriers to productive use. A multifaceted usability approach provided important insight regarding use of technology by an elderly chronic-care patient population and more generally, for understanding how home health initiatives can more effectively use such technology.
A survey of packages for large linear systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Kesheng; Milne, Brent
2000-02-11
This paper evaluates portable software packages for the iterative solution of very large sparse linear systems on parallel architectures. While we cannot hope to tell individual users which package will best suit their needs, we do hope that our systematic evaluation provides essential unbiased information about the packages and the evaluation process may serve as an example on how to evaluate these packages. The information contained here include feature comparisons, usability evaluations and performance characterizations. This review is primarily focused on self-contained packages that can be easily integrated into an existing program and are capable of computing solutions to verymore » large sparse linear systems of equations. More specifically, it concentrates on portable parallel linear system solution packages that provide iterative solution schemes and related preconditioning schemes because iterative methods are more frequently used than competing schemes such as direct methods. The eight packages evaluated are: Aztec, BlockSolve,ISIS++, LINSOL, P-SPARSLIB, PARASOL, PETSc, and PINEAPL. Among the eight portable parallel iterative linear system solvers reviewed, we recommend PETSc and Aztec for most application programmers because they have well designed user interface, extensive documentation and very responsive user support. Both PETSc and Aztec are written in the C language and are callable from Fortran. For those users interested in using Fortran 90, PARASOL is a good alternative. ISIS++is a good alternative for those who prefer the C++ language. Both PARASOL and ISIS++ are relatively new and are continuously evolving. Thus their user interface may change. In general, those packages written in Fortran 77 are more cumbersome to use because the user may need to directly deal with a number of arrays of varying sizes. Languages like C++ and Fortran 90 offer more convenient data encapsulation mechanisms which make it easier to implement a clean and intuitive user interface. In addition to reviewing these portable parallel iterative solver packages, we also provide a more cursory assessment of a range of related packages, from specialized parallel preconditioners to direct methods for sparse linear systems.« less
Characterization of microcracks by application of digital image correlation to SPM images
NASA Astrophysics Data System (ADS)
Keller, Juergen; Gollhardt, Astrid; Vogel, Dietmar; Michel, Bernd
2004-07-01
With the development of micro- and nanotechnological products such as sensors, MEMS/NEMS and their broad application in a variety of market segments new reliability issues will arise. The increasing interface-to-volume ratio in highly integrated systems and nanoparticle filled materials and unsolved questions of size effect of nanomaterials are challenges for experimental reliability evaluation. To fulfill this needs the authors developed the nanoDAC method (nano Deformation Analysis by Correlation), which allows the determination and evaluation of 2D displacement fields based on scanning probe microscopy (SPM) data. In-situ SPM scans of the analyzed object are carried out at different thermo-mechanical load states. The obtained topography-, phase- or error-images are compared utilizing grayscale cross correlation algorithms. This allows the tracking of local image patterns of the analyzed surface structure. The measurement results of the nanoDAC method are full-field displacement and strain fields. Due to the application of SPM equipment deformations in the micro-, nanometer range can be easily detected. The method can be performed on bulk materials, thin films and on devices i.e microelectronic components, sensors or MEMS/NEMS. Furthermore, the characterization and evaluation of micro- and nanocracks or defects in bulk materials, thin layers and at material interfaces can be carried out.
Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A.
2013-01-01
Context The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. Methods We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System – PITTCat. Results Twenty relevant studies were identified. Conclusion Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators. PMID:23820143
A Fuzzy Integral Ensemble Method in Visual P300 Brain-Computer Interface.
Cavrini, Francesco; Bianchi, Luigi; Quitadamo, Lucia Rita; Saggio, Giovanni
2016-01-01
We evaluate the possibility of application of combination of classifiers using fuzzy measures and integrals to Brain-Computer Interface (BCI) based on electroencephalography. In particular, we present an ensemble method that can be applied to a variety of systems and evaluate it in the context of a visual P300-based BCI. Offline analysis of data relative to 5 subjects lets us argue that the proposed classification strategy is suitable for BCI. Indeed, the achieved performance is significantly greater than the average of the base classifiers and, broadly speaking, similar to that of the best one. Thus the proposed methodology allows realizing systems that can be used by different subjects without the need for a preliminary configuration phase in which the best classifier for each user has to be identified. Moreover, the ensemble is often capable of detecting uncertain situations and turning them from misclassifications into abstentions, thereby improving the level of safety in BCI for environmental or device control.
Kuzu, Guray; Keskin, Ozlem; Nussinov, Ruth; Gursoy, Attila
2016-10-01
The structures of protein assemblies are important for elucidating cellular processes at the molecular level. Three-dimensional electron microscopy (3DEM) is a powerful method to identify the structures of assemblies, especially those that are challenging to study by crystallography. Here, a new approach, PRISM-EM, is reported to computationally generate plausible structural models using a procedure that combines crystallographic structures and density maps obtained from 3DEM. The predictions are validated against seven available structurally different crystallographic complexes. The models display mean deviations in the backbone of <5 Å. PRISM-EM was further tested on different benchmark sets; the accuracy was evaluated with respect to the structure of the complex, and the correlation with EM density maps and interface predictions were evaluated and compared with those obtained using other methods. PRISM-EM was then used to predict the structure of the ternary complex of the HIV-1 envelope glycoprotein trimer, the ligand CD4 and the neutralizing protein m36.
Developing criteria to establish Trusted Digital Repositories
Faundeen, John L.
2017-01-01
This paper details the drivers, methods, and outcomes of the U.S. Geological Survey’s quest to establish criteria by which to judge its own digital preservation resources as Trusted Digital Repositories. Drivers included recent U.S. legislation focused on data and asset management conducted by federal agencies spending $100M USD or more annually on research activities. The methods entailed seeking existing evaluation criteria from national and international organizations such as International Standards Organization (ISO), U.S. Library of Congress, and Data Seal of Approval upon which to model USGS repository evaluations. Certification, complexity, cost, and usability of existing evaluation models were key considerations. The selected evaluation method was derived to allow the repository evaluation process to be transparent, understandable, and defensible; factors that are critical for judging competing, internal units. Implementing the chosen evaluation criteria involved establishing a cross-agency, multi-disciplinary team that interfaced across the organization.
Cui, Licong; Carter, Rebecca
2014-01-01
Background Numerous consumer health information websites have been developed to provide consumers access to health information. However, lookup search is insufficient for consumers to take full advantage of these rich public information resources. Exploratory search is considered a promising complementary mechanism, but its efficacy has never before been rigorously evaluated for consumer health information retrieval interfaces. Objective This study aims to (1) introduce a novel Conjunctive Exploratory Navigation Interface (CENI) for supporting effective consumer health information retrieval and navigation, and (2) evaluate the effectiveness of CENI through a search-interface comparative evaluation using crowdsourcing with Amazon Mechanical Turk (AMT). Methods We collected over 60,000 consumer health questions from NetWellness, one of the first consumer health websites to provide high-quality health information. We designed and developed a novel conjunctive exploratory navigation interface to explore NetWellness health questions with health topics as dynamic and searchable menus. To investigate the effectiveness of CENI, we developed a second interface with keyword-based search only. A crowdsourcing comparative study was carefully designed to compare three search modes of interest: (A) the topic-navigation-based CENI, (B) the keyword-based lookup interface, and (C) either the most commonly available lookup search interface with Google, or the resident advanced search offered by NetWellness. To compare the effectiveness of the three search modes, 9 search tasks were designed with relevant health questions from NetWellness. Each task included a rating of difficulty level and questions for validating the quality of answers. Ninety anonymous and unique AMT workers were recruited as participants. Results Repeated-measures ANOVA analysis of the data showed the search modes A, B, and C had statistically significant differences among their levels of difficulty (P<.001). Wilcoxon signed-rank test (one-tailed) between A and B showed that A was significantly easier than B (P<.001). Paired t tests (one-tailed) between A and C showed A was significantly easier than C (P<.001). Participant responses on the preferred search modes showed that 47.8% (43/90) participants preferred A, 25.6% (23/90) preferred B, 24.4% (22/90) preferred C. Participant comments on the preferred search modes indicated that CENI was easy to use, provided better organization of health questions by topics, allowed users to narrow down to the most relevant contents quickly, and supported the exploratory navigation by non-experts or those unsure how to initiate their search. Conclusions We presented a novel conjunctive exploratory navigation interface for consumer health information retrieval and navigation. Crowdsourcing permitted a carefully designed comparative search-interface evaluation to be completed in a timely and cost-effective manner with a relatively large number of participants recruited anonymously. Accounting for possible biases, our study has shown for the first time with crowdsourcing that the combination of exploratory navigation and lookup search is more effective than lookup search alone. PMID:24513593
NASA Astrophysics Data System (ADS)
Nehar, K. C.; Hachi, B. E.; Cazes, F.; Haboussi, M.
2017-12-01
The aim of the present work is to investigate the numerical modeling of interfacial cracks that may appear at the interface between two isotropic elastic materials. The extended finite element method is employed to analyze brittle and bi-material interfacial fatigue crack growth by computing the mixed mode stress intensity factors (SIF). Three different approaches are introduced to compute the SIFs. In the first one, mixed mode SIF is deduced from the computation of the contour integral as per the classical J-integral method, whereas a displacement method is used to evaluate the SIF by using either one or two displacement jumps located along the crack path in the second and third approaches. The displacement jump method is rather classical for mono-materials, but has to our knowledge not been used up to now for a bi-material. Hence, use of displacement jump for characterizing bi-material cracks constitutes the main contribution of the present study. Several benchmark tests including parametric studies are performed to show the effectiveness of these computational methodologies for SIF considering static and fatigue problems of bi-material structures. It is found that results based on the displacement jump methods are in a very good agreement with those of exact solutions, such as for the J-integral method, but with a larger domain of applicability and a better numerical efficiency (less time consuming and less spurious boundary effect).
Vermeulen, Joan; Neyens, Jacques C. L; Spreeuwenberg, Marieke D; Van Rossum, Erik; Hewson, David; De Witte, Luc P
2012-01-01
Background The number of frail elderly people is increasing. Unfortunately, the number of caregivers is not increasing at the same pace, which affects older people, caregivers and healthcare systems. Because of these developments, self-management is becoming more important in healthcare. To support community-dwelling elderly people in their self-management, a system was developed that monitors their physical functioning. This system provides feedback to elderly people and their caregivers regarding physical indicators of frailty. The feedback is provided to elderly people via the screen of a mobile phone. It is important that elderly people understand the content of the feedback and are able to use the mobile phone properly. If not, it is unlikely that the system can support self-management. Many interactive health technologies that have been developed do not fulfil their promises. An important reason for this is that human and other non-technology issues are not sufficiently taken into consideration during the development process. Objective To collaborate with elderly people during the development and evaluation of a feedback system for community-dwelling elderly people regarding physical functioning. Methods An iterative user-centered design that consists of five phases was used to develop and evaluate the feedback system. These five phases were: 1) Selection of users, 2) Analysis of users and their context, 3) Identification of user needs, 4) Development of a prototype, and 5) Evaluation of the prototype. Three representatives of a target group panel for elderly people were selected in phase 1. They shared their needs and preferences during three expert group meetings that took place during the development process. This resulted in the development of a prototype which was first evaluated in a heuristic evaluation. Once adjustments were made, 11 elderly people evaluated the adjusted prototype using a think aloud procedure. They rated the usability and acceptability of the developed interface on a scale from 1 till 7 using an adapted version of the Post-Study System Usability Questionnaire (PSSUQ). Results A feedback system was developed that provides feedback regarding physical indicators of frailty via a touch screen mobile phone. The interface uses colours, smiley’s, and spoken/written messages to provide feedback that is easy to understand. The heuristic evaluation revealed that there were some problems with consistency and the use of user language. The think aloud evaluation showed that the 11 elderly people were able to navigate through the interface without much difficulty despite some small problems related to the lay-out of the interface. The mean score on an adapted version of the PSSUQ was 5.90 (SD 1.09) which indicates high user satisfaction and good usability. Conclusions The involvement of end-users significantly influenced the lay-out of the interface that was developed. This resulted in an interface that was accepted by the target group. Evaluation of the prototype revealed that the usability of the interface was good. The feedback system will only succeed in supporting self-management when elderly people are able to use the interface and understand the feedback. The input of elderly people during the development process contributed to this.
Tracking BO6 Coupling in Perovskite Superlattices to Engineer Magnetic Interface Behavior
NASA Astrophysics Data System (ADS)
Borisevich, Albina; He, Qian; Ghosh, Saurabh; Moon, Eun Ju; May, Steve; Lupini, Andrew; Pantelides, Sokrates
In the past several years, control of BO6 octahedral coupling at ABO3 perovskite interfaces has emerged as a new tool for engineering of interface properties due to its strong coupling to polar and magnetic properties. High resolution data on tilt transitions at interfaces is instrumental for evaluating the validity of existing theoretical models and developing predictive theories. Recently, we have developed a unique method to investigate BO6 rotation patterns in complex oxides with unit cell resolution. Our method involves column shape analysis in ABF-STEM images of the perovskite heterointerfaces taken in specific orientations. This method will allow us to determine local symmetry between adjacent unit cells, revealing the BO6 coupling behavior at heterointerfaces in 3D. This technique was used to characterize structure and predict properties via a combined STEM and DFT study of magnetic superlattice of La(Ca)MnO3/La(Sr)MnO3 with different periodicities, which exhibit a range of electromagnetic coupling behaviors. We will also discuss the prospects for tilted structure determination using electron ptychography. The correlations among the BO6 rotation, domain size, superlattice periodicity and the electromagnetic coupling will be discussed in detail. Research supported by the MSED of the U.S.DOE, and through a user project at ORNL's CNMS, sponsored by the SUFD of the U.S. DOE.
Simulation in a dynamic prototyping environment: Petri nets or rules?
NASA Technical Reports Server (NTRS)
Moore, Loretta A.; Price, Shannon W.; Hale, Joseph P.
1994-01-01
An evaluation of a prototyped user interface is best supported by a simulation of the system. A simulation allows for dynamic evaluation of the interface rather than just a static evaluation of the screen's appearance. This allows potential users to evaluate both the look (in terms of the screen layout, color, objects, etc.) and feel (in terms of operations and actions which need to be performed) of a system's interface. Because of the need to provide dynamic evaluation of an interface, there must be support for producing active simulations. The high-fidelity training simulators are normally delivered too late to be effectively used in prototyping the displays. Therefore, it is important to build a low fidelity simulator, so that the iterative cycle of refining the human computer interface based upon a user's interactions can proceed early in software development.
Simulation in a dynamic prototyping environment: Petri nets or rules?
NASA Technical Reports Server (NTRS)
Moore, Loretta A.; Price, Shannon; Hale, Joseph P.
1994-01-01
An evaluation of a prototyped user interface is best supported by a simulation of the system. A simulation allows for dynamic evaluation of the interface rather than just a static evaluation of the screen's appearance. This allows potential users to evaluate both the look (in terms of the screen layout, color, objects, etc.) and feel (in terms of operations and actions which need to be performed) of a system's interface. Because of the need to provide dynamic evaluation of an interface, there must be support for producing active simulations. The high-fidelity training simulators are delivered too late to be effectively used in prototyping the displays. Therefore, it is important to build a low fidelity simulator, so that the iterative cycle of refining the human computer interface based upon a user's interactions can proceed early in software development.
Method and apparatus for connecting finite element meshes and performing simulations therewith
Dohrmann, Clark R.; Key, Samuel W.; Heinstein, Martin W.
2003-05-06
The present invention provides a method of connecting dissimilar finite element meshes. A first mesh, designated the master mesh, and a second mesh, designated the slave mesh, each have interface surfaces proximal the other. Each interface surface has a corresponding interface mesh comprising a plurality of interface nodes. Each slave interface node is assigned new coordinates locating the interface node on the interface surface of the master mesh. The slave interface surface is further redefined to be the projection of the slave interface mesh onto the master interface surface.
Influence of different tightening forces before laser welding to the implant/framework fit.
da Silveira-Júnior, Clebio Domingues; Neves, Flávio Domingues; Fernandes-Neto, Alfredo Júlio; Prado, Célio Jesus; Simamoto-Júnior, Paulo César
2009-06-01
The aim of the present study was to evaluate the influence of abutment screw tightening force before laser welding procedures on the vertical fit of metal frameworks over four implants. To construct the frameworks, prefabricated titanium abutments and cylindrical titanium bars were joined by laser welding to compose three groups: group of manual torque (GMT), GT10 and GT20. Before welding, manual torque simulating routine laboratory procedure was applied to GTM. In GT10 and GT20, the abutment screws received 10 and 20 Ncm torque, respectively. After welding, the implant/framework interfaces were assessed by optical comparator microscope using two methods. First, the single screw test (SST) was used, in which the interfaces of the screwed and non-screwed abutments were assessed, considering only the abutments at the framework extremities. Second, the interfaces of all the abutments were evaluated when they were screwed. In the SST, intergroup analysis (Kruskal Wallis) showed no significant difference among the three conditions of tightening force; that is, the different tightening force before welding did not guarantee smaller distortions. Intragroup analysis (Wilcoxon) showed that for all groups, the interfaces of the non-screwed abutments were statistically greater than the interfaces of the screwed abutments, evidencing distortions in all the frameworks. ANOVA was applied for the comparison of interfaces when all the abutments were screwed and showed no significant difference among the groups. Under the conditions of this study, pre-welding tightness on abutment screws did not influence the vertical fit of implant-supported metal frameworks.
Speech emotion recognition methods: A literature review
NASA Astrophysics Data System (ADS)
Basharirad, Babak; Moradhaseli, Mohammadreza
2017-10-01
Recently, attention of the emotional speech signals research has been boosted in human machine interfaces due to availability of high computation capability. There are many systems proposed in the literature to identify the emotional state through speech. Selection of suitable feature sets, design of a proper classifications methods and prepare an appropriate dataset are the main key issues of speech emotion recognition systems. This paper critically analyzed the current available approaches of speech emotion recognition methods based on the three evaluating parameters (feature set, classification of features, accurately usage). In addition, this paper also evaluates the performance and limitations of available methods. Furthermore, it highlights the current promising direction for improvement of speech emotion recognition systems.
Usability study of a computer-based self-management system for older adults with chronic diseases.
Or, Calvin; Tao, Da
2012-11-08
Usability can influence patients' acceptance and adoption of a health information technology. However, little research has been conducted to study the usability of a self-management health care system, especially one geared toward elderly patients. This usability study evaluated a new computer-based self-management system interface for older adults with chronic diseases, using a paper prototype approach. Fifty older adults with different chronic diseases participated. Two usability evaluation methods were involved: (1) a heuristics evaluation and (2) end-user testing with a think-aloud testing method, audio recording, videotaping, and interviewing. A set of usability metrics was employed to determine the overall system usability, including task incompletion rate, task completion time, frequency of error, frequency of help, satisfaction, perceived usefulness, and perceived ease of use. Interviews were used to elicit participants' comments on the system design. The quantitative data were analyzed using descriptive statistics and the qualitative data were analyzed for content. The participants were able to perform the predesigned self-management tasks with the current system design and they expressed mostly positive responses about the perceived usability measures regarding the system interface. However, the heuristics evaluation, performance measures, and interviews revealed a number of usability problems related to system navigation, information search and interpretation, information presentation, and readability. Design recommendations for further system interface modifications were discussed. This study verified the usability of the self-management system developed for older adults with chronic diseases. Also, we demonstrated that our usability evaluation approach could be used to quickly and effectively identify usability problems in a health care information system at an early stage of the system development process using a paper prototype. Conducting a usability evaluation is an essential step in system development to ensure that the system features match the users' true needs, expectations, and characteristics, and also to minimize the likelihood of the users committing user errors and having difficulties using the system.
System and methods for reducing harmonic distortion in electrical converters
Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M
2013-12-03
Systems and methods are provided for delivering energy using an energy conversion module. An exemplary method for delivering energy from an input interface to an output interface using an energy converison module coupled between the input interface and the output interface comprises the steps of determining an input voltage reference for the input interface based on a desired output voltage and a measured voltage and the output interface, determining a duty cycle control value based on a ratio of the input voltage reference and the measured voltage, operating one or more switching elements of the energy conversion module to deliver energy from the input interface to the output interface to the output interface with a duty cycle influenced by the dute cycle control value.
NASA Astrophysics Data System (ADS)
Jagannadham, K.
2018-01-01
TiC and TiN films were deposited by reactive magnetron sputtering on Si substrates. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) characterization of the microstructure and interface structure have been carried out and the stoichiometric composition of TiC is determined. Thermal conductivity and interface thermal conductance between different layers in the films are evaluated by the transient thermo reflectance (TTR) and three-omega (3- ω) methods. The results showed that the thermal conductivity of the TiC films increased with temperature. The thermal conductivity of TiC in the absence of TiN is dominated by phonon contribution. The electronic contribution to the thermal conductivity of TiC in the presence of TiN is found to be more significant. The interface thermal conductance of the TiC/TiN interface is much larger than that of interfaces at Au/TiC, TiC/Si, or TiN/Si. The interface thermal conductance between TiC and TiN is reduced by the layer formed as a result of interdiffusion.
NASA Astrophysics Data System (ADS)
Shiomi, Hiromu; Kitai, Hidenori; Tsujimura, Masatoshi; Kiuchi, Yuji; Nakata, Daisuke; Ono, Shuichi; Kojima, Kazutoshi; Fukuda, Kenji; Sakamoto, Kunihiro; Yamasaki, Kimiyohi; Okumura, Hajime
2016-04-01
The effects of oxynitridation and wet oxidation at the interface of SiO2/4H-SiC(0001) and (000\\bar{1}) were investigated using both electrical and physical characterization methods. Hall measurements and split capacitance-voltage (C-V) measurements revealed that the difference in field-effect mobility between wet oxide and dry oxynitride interfaces was mainly attributed to the ratio of the mobile electron density to the total induced electron density. The surface states close to the conduction band edge causing a significant trapping of inversion carriers were also evaluated. High-resolution Rutherford backscattering spectroscopy (HR-RBS) analysis and high-resolution elastic recoil detection analysis (HR-ERDA) were employed to show the nanometer-scale compositional profile of the SiC-MOS interfaces for the first time. These analyses, together with cathode luminescence (CL) spectroscopy and transmission electron microscopy (TEM), suggested that the deviations of stoichiometry and roughness at the interface defined the effects of oxynitridation and wet oxidation at the interface of SiO2/4H-SiC(0001) and (000\\bar{1}).
Evaluating a voice recognition system: finding the right product for your department.
Freeh, M; Dewey, M; Brigham, L
2001-06-01
The Department of Radiology at the University of Utah Health Sciences Center has been in the process of transitioning from the traditional film-based department to a digital imaging department for the past 2 years. The department is now transitioning from the traditional method of dictating reports (dictation by radiologist to transcription to review and signing by radiologist) to a voice recognition system. The transition to digital operations will not be complete until we have the ability to directly interface the dictation process with the image review process. Voice recognition technology has advanced to the level where it can and should be an integral part of the new way of working in radiology and is an integral part of an efficient digital imaging department. The transition to voice recognition requires the task of identifying the product and the company that will best meet a department's needs. This report introduces the methods we used to evaluate the vendors and the products available as we made our purchasing decision. We discuss our evaluation method and provide a checklist that can be used by other departments to assist with their evaluation process. The criteria used in the evaluation process fall into the following major categories: user operations, technical infrastructure, medical dictionary, system interfaces, service support, cost, and company strength. Conclusions drawn from our evaluation process will be detailed, with the intention being to shorten the process for others as they embark on a similar venture. As more and more organizations investigate the many products and services that are now being offered to enhance the operations of a radiology department, it becomes increasingly important that solid methods are used to most effectively evaluate the new products. This report should help others complete the task of evaluating a voice recognition system and may be adaptable to other products as well.
Heuristic Evaluation on Mobile Interfaces: A New Checklist
Yáñez Gómez, Rosa; Cascado Caballero, Daniel; Sevillano, José-Luis
2014-01-01
The rapid evolution and adoption of mobile devices raise new usability challenges, given their limitations (in screen size, battery life, etc.) as well as the specific requirements of this new interaction. Traditional evaluation techniques need to be adapted in order for these requirements to be met. Heuristic evaluation (HE), an Inspection Method based on evaluation conducted by experts over a real system or prototype, is based on checklists which are desktop-centred and do not adequately detect mobile-specific usability issues. In this paper, we propose a compilation of heuristic evaluation checklists taken from the existing bibliography but readapted to new mobile interfaces. Selecting and rearranging these heuristic guidelines offer a tool which works well not just for evaluation but also as a best-practices checklist. The result is a comprehensive checklist which is experimentally evaluated as a design tool. This experimental evaluation involved two software engineers without any specific knowledge about usability, a group of ten users who compared the usability of a first prototype designed without our heuristics, and a second one after applying the proposed checklist. The results of this experiment show the usefulness of the proposed checklist for avoiding usability gaps even with nontrained developers. PMID:25295300
Applying usability heuristics to radiotherapy systems.
Chan, Alvita J; Islam, Mohammad K; Rosewall, Tara; Jaffray, David A; Easty, Anthony C; Cafazzo, Joseph A
2012-01-01
Heuristic evaluations have been used to evaluate safety of medical devices by identifying and assessing usability issues. Since radiotherapy treatment delivery systems often consist of multiple complex user-interfaces, a heuristic evaluation was conducted to assess the potential safety issues of such a system. A heuristic evaluation was conducted to evaluate the treatment delivery system at Princess Margaret Hospital (Toronto, Canada). Two independent evaluators identified usability issues with the user-interfaces and rated the severity of each issue. The evaluators identified 75 usability issues in total. Eighteen of them were rated as high severity, indicating the potential to have a major impact on patient safety. A majority of issues were found on the record and verify system, and many were associated with the patient setup process. While the hospital has processes in place to ensure patient safety, recommendations were developed to further mitigate the risks of potential consequences. Heuristic evaluation is an efficient and inexpensive method that can be successfully applied to radiotherapy delivery systems to identify usability issues and improve patient safety. Although this study was conducted only at one site, the findings may have broad implications for the design of these systems. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, S; Suh, T; Chung, J
2015-06-15
Purpose: To verify the dose accuracy of Acuros XB (AXB) dose calculation algorithm at air-tissue interface using inhomogeneous phantom for 6-MV flattening filter-free (FFF) beams. Methods: An inhomogeneous phantom included air cavity was manufactured for verifying dose accuracy at the air-tissue interface. The phantom was composed with 1 and 3 cm thickness of air cavity. To evaluate the central axis doses (CAD) and dose profiles of the interface, the dose calculations were performed for 3 × 3 and 4 × 4 cm{sup 2} fields of 6 MV FFF beams with AAA and AXB in Eclipse treatment plainning system. Measurements inmore » this region were performed with Gafchromic film. The root mean square errors (RMSE) were analyzed with calculated and measured dose profile. Dose profiles were divided into inner-dose profile (>80%) and penumbra (20% to 80%) region for evaluating RMSE. To quantify the distribution difference, gamma evaluation was used and determined the agreement with 3%/3mm criteria. Results: The percentage differences (%Diffs) between measured and calculated CAD in the interface, AXB shows more agreement than AAA. The %Diffs were increased with increasing the thickness of air cavity size and it is similar for both algorithms. In RMSEs of inner-profile, AXB was more accurate than AAA. The difference was up to 6 times due to overestimation by AAA. RMSEs of penumbra appeared to high difference for increasing the measurement depth. Gamma agreement also presented that the passing rates decreased in penumbra. Conclusion: This study demonstrated that the dose calculation with AXB shows more accurate than with AAA for the air-tissue interface. The 2D dose distributions with AXB for both inner-profile and penumbra showed better agreement than with AAA relative to variation of the measurement depths and air cavity sizes.« less
Melo Freire, C A; Borges, G A; Caldas, Dbm; Santos, R S; Ignácio, S A; Mazur, R F
To evaluate the cement line thickness and the interface quality in milled or injected lithium disilicate ceramic restorations and their influence on marginal adaptation using different cement types and different adhesive cementation techniques. Sixty-four bovine teeth were prepared for full crown restoration (7.0±0.5 mm in height, 8.0 mm in cervical diameter, and 4.2 mm in incisal diameter) and were divided into two groups: CAD/CAM automation technology, IPS e.max CAD (CAD), and isostatic injection by heat technology, IPS e.max Press (PRESS). RelyX ARC (ARC) and RelyX U200 resin cements were used as luting agents in two activation methods: initial self-activation and light pre-activation for one second (tack-cure). Next, the specimens were stored in distilled water at 23°C ± 2°C for 72 hours. The cement line thickness was measured in micrometers, and the interface quality received scores according to the characteristics and sealing aspects. The evaluations were performed with an optical microscope, and scanning electron microscope images were presented to demonstrate the various features found in the cement line. For the cement line thickness, data were analyzed with three-way analysis of variance (ANOVA) and the Games-Howell test (α=0.05). For the variable interface quality, the data were analyzed with the Mann-Whitney U-test, the Kruskal-Wallis test, and multiple comparisons nonparametric Dunn test (α=0.05). The ANOVA presented statistical differences among the ceramic restoration manufacturing methods as well as a significant interaction between the manufacturing methods and types of cement (p<0.05). The U200 presented lower cement line thickness values when compared to the ARC with both cementation techniques (p<0.05). With regard to the interface quality, the Mann-Whitney U-test and the Kruskal-Wallis test demonstrated statistical differences between the ceramic restoration manufacturing methods and cementation techniques. The PRESS ceramics obtained lower scores than did the CAD ceramics when using ARC cement (p<0.05). Milled restorations cemented with self-adhesive resin cement resulted in a thinner cement line that is statistically different from that of CAD or pressed ceramics cemented with resin cement with adhesive application. No difference between one-second tack-cure and self-activation was noted.
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negrutiu, Meda Lavinia; Ionita, Ciprian; Topala, Florin; Petrescu, Emanuela; Rominu, Roxana; Pop, Daniela Maria; Marsavina, Liviu; Negru, Radu; Bradu, Adrian; Rominu, Mihai; Podoleanu, Adrian Gh.
2010-12-01
Imagistic investigation of the metal-ceramic crowns and fixed partial prostheses represent a very important issue in nowadays dentistry. At this time, in dental office, it is difficult or even impossible to evaluate a metal ceramic crown or bridge before setting it in the oral cavity. The possibilities of ceramic fractures are due to small fracture lines or material defects inside the esthetic layers. Material and methods: In this study 25 metal ceramic crowns and fixed partial prostheses were investigated by radiographic method (Rx), micro computer tomography (MicroCT) and optical coherence tomography (OCT) working in Time Domain, at 1300 nm. The OCT system contains two interferometers and one scanner. For each incident analysis a stuck made of 100 slices was obtain. These slices were used in order to obtain a 3D model of the ceramic interface. Results: RX and MicroCT are very powerful instruments that provide a good characterization of the dental construct. It is important to observe the reflections due to the metal infrastructure that could affect the evaluation of the metal ceramic crowns and bridges. The OCT investigations could complete the imagistic evaluation of the dental construct by offering important information when it is need it.
Alppay, Cem; Bayazit, Nigan
2015-11-01
In this paper, we study the arrangement of displays in flight instrument panels of multi-purpose civil helicopters following a user-centered design method based on ergonomics principles. Our methodology can also be described as a user-interface arrangement methodology based on user opinions and preferences. This study can be outlined as gathering user-centered data using two different research methods and then analyzing and integrating the collected data to come up with an optimal instrument panel design. An interview with helicopter pilots formed the first step of our research. In that interview, pilots were asked to provide a quantitative evaluation of basic interface arrangement principles. In the second phase of the research, a paper prototyping study was conducted with same pilots. The final phase of the study entailed synthesizing the findings from interviews and observational studies to formulate an optimal flight instrument arrangement methodology. The primary results that we present in our paper are the methodology that we developed and three new interface arrangement concepts, namely relationship of inseparability, integrated value and locational value. An optimum instrument panel arrangement is also proposed by the researchers. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
AVCS Simulator Test Plan and Design Guide
NASA Technical Reports Server (NTRS)
Shelden, Stephen
2001-01-01
Internal document for communication of AVCS direction and documentation of simulator functionality. Discusses methods for AVCS simulation evaluation of pilot functions, implementation strategy of varying functional representation of pilot tasks (by instantiations of a base AVCS to reasonably approximate the interface of various vehicles -- e.g. Altair, GlobalHawk, etc.).
7 CFR 1755.910 - RUS specification for outside plant housings and serving area interface systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... requirements are interrelated to several tests designed to determine the performance aspects of terminals and... environments. Included are the mechanical, electrical, and environmental requirements, desired design features, and test methods for evaluation of the product. (2) The housing and terminal requirements reflect the...
7 CFR 1755.910 - RUS specification for outside plant housings and serving area interface systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... requirements are interrelated to several tests designed to determine the performance aspects of terminals and... environments. Included are the mechanical, electrical, and environmental requirements, desired design features, and test methods for evaluation of the product. (2) The housing and terminal requirements reflect the...
7 CFR 1755.910 - RUS specification for outside plant housings and serving area interface systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... requirements are interrelated to several tests designed to determine the performance aspects of terminals and... environments. Included are the mechanical, electrical, and environmental requirements, desired design features, and test methods for evaluation of the product. (2) The housing and terminal requirements reflect the...
7 CFR 1755.910 - RUS specification for outside plant housings and serving area interface systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... requirements are interrelated to several tests designed to determine the performance aspects of terminals and... environments. Included are the mechanical, electrical, and environmental requirements, desired design features, and test methods for evaluation of the product. (2) The housing and terminal requirements reflect the...
Conventional in vitro exposure studies of airborne pollutants involve, for example, the addition of particulate matter (PM) or PM extracts to the cell culture medium, or the bubbling of gases into the culture medium; these methods alter the pollutant’s physical and chemical...
ERIC Educational Resources Information Center
Belkin, N. J.; Cool, C.; Kelly, D.; Lin, S. -J.; Park, S. Y.; Perez-Carballo, J.; Sikora, C.
2001-01-01
Reports on the progressive investigation of techniques for supporting interactive query reformulation in the TREC (Text Retrieval Conference) Interactive Track. Highlights include methods of term suggestion; interface design to support different system functionalities; an overview of each year's TREC investigation; and relevance to the development…
Optimizing energy functions for protein-protein interface design.
Sharabi, Oz; Yanover, Chen; Dekel, Ayelet; Shifman, Julia M
2011-01-15
Protein design methods have been originally developed for the design of monomeric proteins. When applied to the more challenging task of protein–protein complex design, these methods yield suboptimal results. In particular, they often fail to recapitulate favorable hydrogen bonds and electrostatic interactions across the interface. In this work, we aim to improve the energy function of the protein design program ORBIT to better account for binding interactions between proteins. By using the advanced machine learning framework of conditional random fields, we optimize the relative importance of all the terms in the energy function, attempting to reproduce the native side-chain conformations in protein–protein interfaces. We evaluate the performance of several optimized energy functions, each describes the van der Waals interactions using a different potential. In comparison with the original energy function, our best energy function (a) incorporates a much “softer” repulsive van der Waals potential, suitable for the discrete rotameric representation of amino acid side chains; (b) does not penalize burial of polar atoms, reflecting the frequent occurrence of polar buried residues in protein–protein interfaces; and (c) significantly up-weights the electrostatic term, attesting to the high importance of these interactions for protein–protein complex formation. Using this energy function considerably improves side chain placement accuracy for interface residues in a large test set of protein–protein complexes. Moreover, the optimized energy function recovers the native sequences of protein–protein interface at a higher rate than the default function and performs substantially better in predicting changes in free energy of binding due to mutations.
ON THE DURABILITY OF RESIN-DENTIN BONDS: IDENTIFYING THE WEAKEST LINKS
Zhang, Zihou; Beitzel, Dylan; Mutluay, Mustafa; Tay, Franklin R.; Pashley, David H.; Arola, Dwayne
2015-01-01
Fatigue of resin-dentin adhesive bonds is critical to the longevity of resin composite restorations. Objectives The objectives were to characterize the fatigue and fatigue crack growth resistance of resin-dentin bonds achieved using two different commercial adhesives and to identify apparent “weak-links”. Methods Bonded interface specimens were prepared using Adper Single Bond Plus (SB) or Adper Scotchbond Multi-Purpose (SBMP) adhesives and 3M Z100 resin composite according to the manufacturers instructions. The stress-life fatigue behavior was evaluated using the twin bonded interface approach and the fatigue crack growth resistance was examined using bonded interface Compact Tension (CT) specimens. Fatigue properties of the interfaces were compared to those of the resin-adhesive, resin composite and coronal dentin. Results The fatigue strength of the SBMP interface was significantly greater than that achieved by SB (p≤0.01). Both bonded interfaces exhibited significantly lower fatigue strength than that of the Z100 and dentin. Regarding the fatigue crack growth resistance, the stress intensity threshold (ΔKth) of the SB interface was significantly greater (p≤0.01) than that of the SBMP, whereas the ΔKth of the interfaces was more than twice that of the parent adhesives. Significance Collagen fibril reinforcement of the resin adhesive is essential to the fatigue crack growth resistance of resin-dentin bonds. Resin tags that are not well hybridized into the surrounding intertubular dentin and/or poor collagen integrity are detrimental to the bonded interface durability. PMID:26169318
Performance evaluation of a robot-assisted catheter operating system with haptic feedback.
Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi
2018-06-20
In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.
A Robust Camera-Based Interface for Mobile Entertainment
Roig-Maimó, Maria Francesca; Manresa-Yee, Cristina; Varona, Javier
2016-01-01
Camera-based interfaces in mobile devices are starting to be used in games and apps, but few works have evaluated them in terms of usability or user perception. Due to the changing nature of mobile contexts, this evaluation requires extensive studies to consider the full spectrum of potential users and contexts. However, previous works usually evaluate these interfaces in controlled environments such as laboratory conditions, therefore, the findings cannot be generalized to real users and real contexts. In this work, we present a robust camera-based interface for mobile entertainment. The interface detects and tracks the user’s head by processing the frames provided by the mobile device’s front camera, and its position is then used to interact with the mobile apps. First, we evaluate the interface as a pointing device to study its accuracy, and different factors to configure such as the gain or the device’s orientation, as well as the optimal target size for the interface. Second, we present an in the wild study to evaluate the usage and the user’s perception when playing a game controlled by head motion. Finally, the game is published in an application store to make it available to a large number of potential users and contexts and we register usage data. Results show the feasibility of using this robust camera-based interface for mobile entertainment in different contexts and by different people. PMID:26907288
Evaluation method of the performance of kinetic inhibitor for clathrate hydrate
NASA Astrophysics Data System (ADS)
Muraoka, M.; Susuki, N.; Yamamoto, Y.
2016-12-01
As a part of a Japanese National hydrate research program (MH21, funded by METI), we study the formation of tetrahydrofuran (THF) clathrate hydrate from polyvinylpyrrolidone (PVP) aqueous solution as a function of growth rate V and adsorbed PVP concentration c using the unidirectional growth technique. This study aims to propose a simple method for evaluating the performance of kinetic hydrate inhibitors (KHIs) for the clathrate hydrate-aqueous solution system. The degree of super cooling ΔT calculated from the growth-induced interface shift under steady-state conditions was used for evaluating the KHIs performance. Using this method, a single experimental run can be completed within 3.5 h of the compulsory nucleation by setting V = 5 μm s-1. We believe this method is useful for screening various KHIs and clarifying the inhibition mechanism of KHIs.
Some recent developments of the immersed interface method for flow simulation
NASA Astrophysics Data System (ADS)
Xu, Sheng
2017-11-01
The immersed interface method is a general methodology for solving PDEs subject to interfaces. In this talk, I will give an overview of some recent developments of the method toward the enhancement of its robustness for flow simulation. In particular, I will present with numerical results how to capture boundary conditions on immersed rigid objects, how to adopt interface triangulation in the method, and how to parallelize the method for flow with moving objects. With these developments, the immersed interface method can achieve accurate and efficient simulation of a flow involving multiple moving complex objects. Thanks to NSF for the support of this work under Grant NSF DMS 1320317.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muth, Thomas R.; Peter, William H.
The team performed a literature review, conducted residual stress measurements, performed failure analysis, and demonstrated a solid state additive manufacturing repair technique on samples removed from a scrapped propeller hub. The team evaluated multiple options for hub repair that included existing metal buildup technologies that the Federal Aviation Administration (FAA) has already embraced, such as cold spray, high velocity oxy-fuel deposition (HVOF), and plasma spray. In addition the team helped Piedmont Propulsion Systems, LLC (PPS) evaluate three potential solutions that could be deployed at different stages in the life cycle of aluminum alloy hubs, in addition to the conventional spraymore » coating method for repair. For new hubs, a machining practice to prevent fretting with the steel drive shaft was recommended. For hubs that were refurbished with some material remaining above the minimal material condition (MMC), a silver interface applied by an electromagnetic pulse additive manufacturing method was recommended. For hubs that were at or below the MMC, a solid state additive manufacturing technique using ultrasonic welding (UW) of thin layers of 7075 aluminum to the hub interface was recommended. A cladding demonstration using the UW technique achieved mechanical bonding of the layers showing promise as a viable repair method.« less
Systems and methods for monitoring a solid-liquid interface
Stoddard, Nathan G; Lewis, Monte A.; Clark, Roger F
2013-06-11
Systems and methods are provided for monitoring a solid-liquid interface during a casting process. The systems and methods enable determination of the location of a solid-liquid interface during the casting process.
Second order Method for Solving 3D Elasticity Equations with Complex Interfaces
Wang, Bao; Xia, Kelin; Wei, Guo-Wei
2015-01-01
Elastic materials are ubiquitous in nature and indispensable components in man-made devices and equipments. When a device or equipment involves composite or multiple elastic materials, elasticity interface problems come into play. The solution of three dimensional (3D) elasticity interface problems is significantly more difficult than that of elliptic counterparts due to the coupled vector components and cross derivatives in the governing elasticity equation. This work introduces the matched interface and boundary (MIB) method for solving 3D elasticity interface problems. The proposed MIB elasticity interface scheme utilizes fictitious values on irregular grid points near the material interface to replace function values in the discretization so that the elasticity equation can be discretized using the standard finite difference schemes as if there were no material interface. The interface jump conditions are rigorously enforced on the intersecting points between the interface and the mesh lines. Such an enforcement determines the fictitious values. A number of new techniques has been developed to construct efficient MIB elasticity interface schemes for dealing with cross derivative in coupled governing equations. The proposed method is extensively validated over both weak and strong discontinuity of the solution, both piecewise constant and position-dependent material parameters, both smooth and nonsmooth interface geometries, and both small and large contrasts in the Poisson’s ratio and shear modulus across the interface. Numerical experiments indicate that the present MIB method is of second order convergence in both L∞ and L2 error norms for handling arbitrarily complex interfaces, including biomolecular surfaces. To our best knowledge, this is the first elasticity interface method that is able to deliver the second convergence for the molecular surfaces of proteins.. PMID:25914422
A Galerkin formulation of the MIB method for three dimensional elliptic interface problems
Xia, Kelin; Wei, Guo-Wei
2014-01-01
We develop a three dimensional (3D) Galerkin formulation of the matched interface and boundary (MIB) method for solving elliptic partial differential equations (PDEs) with discontinuous coefficients, i.e., the elliptic interface problem. The present approach builds up two sets of elements respectively on two extended subdomains which both include the interface. As a result, two sets of elements overlap each other near the interface. Fictitious solutions are defined on the overlapping part of the elements, so that the differentiation operations of the original PDEs can be discretized as if there was no interface. The extra coefficients of polynomial basis functions, which furnish the overlapping elements and solve the fictitious solutions, are determined by interface jump conditions. Consequently, the interface jump conditions are rigorously enforced on the interface. The present method utilizes Cartesian meshes to avoid the mesh generation in conventional finite element methods (FEMs). We implement the proposed MIB Galerkin method with three different elements, namely, rectangular prism element, five-tetrahedron element and six-tetrahedron element, which tile the Cartesian mesh without introducing any new node. The accuracy, stability and robustness of the proposed 3D MIB Galerkin are extensively validated over three types of elliptic interface problems. In the first type, interfaces are analytically defined by level set functions. These interfaces are relatively simple but admit geometric singularities. In the second type, interfaces are defined by protein surfaces, which are truly arbitrarily complex. The last type of interfaces originates from multiprotein complexes, such as molecular motors. Near second order accuracy has been confirmed for all of these problems. To our knowledge, it is the first time for an FEM to show a near second order convergence in solving the Poisson equation with realistic protein surfaces. Additionally, the present work offers the first known near second order accurate method for C1 continuous or H2 continuous solutions associated with a Lipschitz continuous interface in a 3D setting. PMID:25309038
Zhang, Qi; Du, Xinhang; Tan, Shengwei; Tang, Dian; Chen, Kongfa; Zhang, Teng
2017-07-13
Nb 2 O 5 is added to a borosilicate sealing system to improve the thermo-mechanical stability of the sealing interface between the glass and Fe-Cr metallic interconnect (Crofer 22APU) in solid oxide fuel cells (SOFCs). The thermo-mechanical stability of the glass/metal interface is evaluated experimentally as well as by using a finite element analysis (FEA) method. The sealing glass doped with 4 mol.% Nb 2 O 5 shows the best thermo-mechanical stability, and the sealing couple of Crofer 22APU/glass/GDC (Gd 0.2 Ce 0.8 O 1.9 ) remains intact after 50 thermal cycles. In addition, all sealing couples show good joining after being held at 750 °C for 1000 h. Moreover, the possible mechanism on the thermo-mechanical stability of sealing interface is investigated in terms of stress-based and energy-based perspectives.
Loret, Thomas; Peyret, Emmanuel; Dubreuil, Marielle; Aguerre-Chariol, Olivier; Bressot, Christophe; le Bihan, Olivier; Amodeo, Tanguy; Trouiller, Bénédicte; Braun, Anne; Egles, Christophe; Lacroix, Ghislaine
2016-11-03
Recently, much progress has been made to develop more physiologic in vitro models of the respiratory system and improve in vitro simulation of particle exposure through inhalation. Nevertheless, the field of nanotoxicology still suffers from a lack of relevant in vitro models and exposure methods to predict accurately the effects observed in vivo, especially after respiratory exposure. In this context, the aim of our study was to evaluate if exposing pulmonary cells at the air-liquid interface to aerosols of inhalable and poorly soluble nanomaterials generates different toxicity patterns and/or biological activation levels compared to classic submerged exposures to suspensions. Three nano-TiO 2 and one nano-CeO 2 were used. An exposure system was set up using VitroCell® devices to expose pulmonary cells at the air-liquid interface to aerosols. A549 alveolar cells in monocultures or in co-cultures with THP-1 macrophages were exposed to aerosols in inserts or to suspensions in inserts and in plates. Submerged exposures in inserts were performed, using similar culture conditions and exposure kinetics to the air-liquid interface, to provide accurate comparisons between the methods. Exposure in plates using classical culture and exposure conditions was performed to provide comparable results with classical submerged exposure studies. The biological activity of the cells (inflammation, cell viability, oxidative stress) was assessed at 24 h and comparisons of the nanomaterial toxicities between exposure methods were performed. Deposited doses of nanomaterials achieved using our aerosol exposure system were sufficient to observe adverse effects. Co-cultures were more sensitive than monocultures and biological responses were usually observed at lower doses at the air-liquid interface than in submerged conditions. Nevertheless, the general ranking of the nanomaterials according to their toxicity was similar across the different exposure methods used. We showed that exposure of cells at the air-liquid interface represents a valid and sensitive method to assess the toxicity of several poorly soluble nanomaterials. We underlined the importance of the cellular model used and offer the possibility to deal with low deposition doses by using more sensitive and physiologic cellular models. This brings perspectives towards the use of relevant in vitro methods of exposure to assess nanomaterial toxicity.
Evaluation of total knee mechanics using a crouching simulator with a synthetic knee substitute.
Lowry, Michael; Rosenbaum, Heather; Walker, Peter S
2016-05-01
Mechanical evaluation of total knees is frequently required for aspects such as wear, strength, kinematics, contact areas, and force transmission. In order to carry out such tests, we developed a crouching simulator, based on the Oxford-type machine, with novel features including a synthetic knee including ligaments. The instrumentation and data processing methods enabled the determination of contact area locations and interface forces and moments, for a full flexion-extension cycle. To demonstrate the use of the simulator, we carried out a comparison of two different total knee designs, cruciate retaining and substituting. The first part of the study describes the simulator design and the methodology for testing the knees without requiring cadaveric knee specimens. The degrees of freedom of the anatomic hip and ankle joints were reproduced. Flexion-extension was obtained by changing quadriceps length, while variable hamstring forces were applied using springs. The knee joint was represented by three-dimensional printed blocks on to which the total knee components were fixed. Pretensioned elastomeric bands of realistic stiffnesses passed through holes in the block at anatomical locations to represent ligaments. Motion capture of the knees during flexion, together with laser scanning and computer modeling, was used to reconstruct contact areas on the bearing surfaces. A method was also developed for measuring tibial component interface forces and moments as a comparative assessment of fixation. The method involved interposing Tekscan pads at locations on the interface. Overall, the crouching machine and the methodology could be used for many different mechanical measurements of total knee designs, adapted especially for comparative or parametric studies. © IMechE 2016.
Wen, C; Ma, Y J
2018-03-01
The determination of atomic structures and further quantitative information such as chemical compositions at atomic scale for semiconductor defects or heteroepitaxial interfaces can provide direct evidence to understand their formation, modification, and/or effects on the properties of semiconductor films. The commonly used method, high-resolution transmission electron microscopy (HRTEM), suffers from difficulty in acquiring images that correctly show the crystal structure at atomic resolution, because of the limitation in microscope resolution or deviation from the Scherzer-defocus conditions. In this study, an image processing method, image deconvolution, was used to achieve atomic-resolution (∼1.0 Å) structure images of small lattice-mismatch (∼1.0%) AlN/6H-SiC (0001) and large lattice-mismatch (∼8.5%) AlSb/GaAs (001) heteroepitaxial interfaces using simulated HRTEM images of a conventional 300-kV field-emission-gun transmission electron microscope under non-Scherzer-defocus conditions. Then, atomic-scale chemical compositions at the interface were determined for the atomic intermixing and Lomer dislocation with an atomic step by analyzing the deconvoluted image contrast. Furthermore, the effect of dynamical scattering on contrast analysis was also evaluated for differently weighted atomic columns in the compositions. Copyright © 2018 Elsevier Ltd. All rights reserved.
Arnau, Antonio
2008-01-01
From the first applications of AT-cut quartz crystals as sensors in solutions more than 20 years ago, the so-called quartz crystal microbalance (QCM) sensor is becoming into a good alternative analytical method in a great deal of applications such as biosensors, analysis of biomolecular interactions, study of bacterial adhesion at specific interfaces, pathogen and microorganism detection, study of polymer film-biomolecule or cell-substrate interactions, immunosensors and an extensive use in fluids and polymer characterization and electrochemical applications among others. The appropriate evaluation of this analytical method requires recognizing the different steps involved and to be conscious of their importance and limitations. The first step involved in a QCM system is the accurate and appropriate characterization of the sensor in relation to the specific application. The use of the piezoelectric sensor in contact with solutions strongly affects its behavior and appropriate electronic interfaces must be used for an adequate sensor characterization. Systems based on different principles and techniques have been implemented during the last 25 years. The interface selection for the specific application is important and its limitations must be known to be conscious of its suitability, and for avoiding the possible error propagation in the interpretation of results. This article presents a comprehensive overview of the different techniques used for AT-cut quartz crystal microbalance in in-solution applications, which are based on the following principles: network or impedance analyzers, decay methods, oscillators and lock-in techniques. The electronic interfaces based on oscillators and phase-locked techniques are treated in detail, with the description of different configurations, since these techniques are the most used in applications for detection of analytes in solutions, and in those where a fast sensor response is necessary. PMID:27879713
Bone regeneration assessment by optical coherence tomography and MicroCT synchrotron radiation
NASA Astrophysics Data System (ADS)
Negrutiu, Meda L.; Sinescu, Cosmin; Canjau, Silvana; Manescu, Adrian; Topalá, Florin I.; Hoinoiu, Bogdan; Romînu, Mihai; Márcáuteanu, Corina; Duma, Virgil; Bradu, Adrian; Podoleanu, Adrian G.
2013-06-01
Bone grafting is a commonly performed surgical procedure to augment bone regeneration in a variety of orthopaedic and maxillofacial procedures, with autologous bone being considered as the "gold standard" bone-grafting material, as it combines all properties required in a bone-graft material: osteoinduction (bone morphogenetic proteins - BMPs - and other growth factors), osteogenesis (osteoprogenitor cells) and osteoconduction (scaffold). The problematic elements of bone regenerative materials are represented by their quality control methods, the adjustment of the initial bone regenerative material, the monitoring (noninvasive, if possible) during their osteoconduction and osteointegration period and biomedical evaluation of the new regenerated bone. One of the research directions was the interface investigation of the regenerative bone materials and their behavior at different time periods on the normal femoral rat bone. 12 rat femurs were used for this investigation. In each ones a 1 mm diameter hole were drilled and a bone grafting material was inserted in the artificial defect. The femurs were removed after one, three and six months. The defects repaired by bone grafting material were evaluated by optical coherence tomography working in Time Domain Mode at 1300 nm. Three dimensional reconstructions of the interfaces were generated. The validations of the results were evaluated by microCT. Synchrotron Radiation allows achieving high spatial resolution images to be generated with high signal-to-noise ratio. In addition, Synchrotron Radiation allows acquisition of volumes at different energies and volume subtraction to enhance contrast. Evaluation of the bone grafting material/bone interface with noninvasive methods such as optical coherence tomography could act as a valuable procedure that can be use in the future in the usual clinical techniques. The results were confirmed by microCT. Optical coherence tomography can be performed in vivo and can provide a qualitative and quantitative evaluation of the bone augmentation procedure.
NASA Technical Reports Server (NTRS)
Trivedi, K. S. (Editor); Clary, J. B. (Editor)
1980-01-01
A computer aided reliability estimation procedure (CARE 3), developed to model the behavior of ultrareliable systems required by flight-critical avionics and control systems, is evaluated. The mathematical models, numerical method, and fault-tolerant architecture modeling requirements are examined, and the testing and characterization procedures are discussed. Recommendations aimed at enhancing CARE 3 are presented; in particular, the need for a better exposition of the method and the user interface is emphasized.
A comparison of locally adaptive multigrid methods: LDC, FAC and FIC
NASA Technical Reports Server (NTRS)
Khadra, Khodor; Angot, Philippe; Caltagirone, Jean-Paul
1993-01-01
This study is devoted to a comparative analysis of three 'Adaptive ZOOM' (ZOom Overlapping Multi-level) methods based on similar concepts of hierarchical multigrid local refinement: LDC (Local Defect Correction), FAC (Fast Adaptive Composite), and FIC (Flux Interface Correction)--which we proposed recently. These methods are tested on two examples of a bidimensional elliptic problem. We compare, for V-cycle procedures, the asymptotic evolution of the global error evaluated by discrete norms, the corresponding local errors, and the convergence rates of these algorithms.
A 3D front tracking method on a CPU/GPU system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bo, Wurigen; Grove, John
2011-01-21
We describe the method to port a sequential 3D interface tracking code to a GPU with CUDA. The interface is represented as a triangular mesh. Interface geometry properties and point propagation are performed on a GPU. Interface mesh adaptation is performed on a CPU. The convergence of the method is assessed from the test problems with given velocity fields. Performance results show overall speedups from 11 to 14 for the test problems under mesh refinement. We also briefly describe our ongoing work to couple the interface tracking method with a hydro solver.
NASA Astrophysics Data System (ADS)
Rusu, Laura-Cristina; Negrutiu, Meda Lavinia; Sinescu, Cosmin; Hoinoiu, Bogdan; Zaharia, Cristian; Ardelean, Lavinia; Duma, Virgil-Florin; Podoleanu, Adrian G.
2014-01-01
The osteoconductive materials are important in bone regeneration procedures. Three dimensional (3D) reconstructions were obtained from the analysis. The aim of this study is to investigate the interface between the femur rat bone and the new bone that is obtained using a method of tissue engineering that is based on two artificial matrixes inserted in previously artificially induced defects. For this study, under strict supervision 20 rats were used in conformity with ethical procedures. In all the femurs a round defect was induced by drilling with a 1 mm spherical Co-Cr surgical drill. The matrixes used were IngeniOss (for ten samples) and 4Bone(for the other ten samples). These materials were inserted into the induced defects. The femurs were investigated at 1 month, after the surgical procedures. The interfaces were examined using Time Domain (TD) Optical Coherence Tomography (OCT) combined with Confocal Microscopy (CM). The scanning procedure is similar to that used in any CM, where the fast scanning is en-face (line rate) and the scanning in depth is much slower (at the frame rate). The optical configuration uses two single mode directional couplers with a superluminiscent diode as the source centered at 1300 nm. The results showed open interfaces due to the insufficient healing process, as well as closed interfaces due to a new bone formation inside the defect. The conclusion of this study is that TD-OCT can act as a valuable tool in the investigation of the interface between the old bone and the one that has been newly created due to the osteoinductive process. The TD-OCT has proven a valuable tool for the non-invasive evaluation of the matrix bone interfaces.
A variationally coupled FE-BE method for elasticity and fracture mechanics
NASA Technical Reports Server (NTRS)
Lu, Y. Y.; Belytschko, T.; Liu, W. K.
1991-01-01
A new method for coupling finite element and boundary element subdomains in elasticity and fracture mechanics problems is described. The essential feature of this new method is that a single variational statement is obtained for the entire domain, and in this process the terms associated with tractions on the interfaces between the subdomains are eliminated. This provides the additional advantage that the ambiguities associated with the matching of discontinuous tractions are circumvented. The method leads to a direct procedure for obtaining the discrete equations for the coupled problem without any intermediate steps. In order to evaluate this method and compare it with previous methods, a patch test for coupled procedures has been devised. Evaluation of this variationally coupled method and other methods, such as stiffness coupling and constraint traction matching coupling, shows that this method is substantially superior. Solutions for a series of fracture mechanics problems are also reported to illustrate the effectiveness of this method.
Borazjani, Iman; Ge, Liang; Le, Trung; Sotiropoulos, Fotis
2013-01-01
We develop an overset-curvilinear immersed boundary (overset-CURVIB) method in a general non-inertial frame of reference to simulate a wide range of challenging biological flow problems. The method incorporates overset-curvilinear grids to efficiently handle multi-connected geometries and increase the resolution locally near immersed boundaries. Complex bodies undergoing arbitrarily large deformations may be embedded within the overset-curvilinear background grid and treated as sharp interfaces using the curvilinear immersed boundary (CURVIB) method (Ge and Sotiropoulos, Journal of Computational Physics, 2007). The incompressible flow equations are formulated in a general non-inertial frame of reference to enhance the overall versatility and efficiency of the numerical approach. Efficient search algorithms to identify areas requiring blanking, donor cells, and interpolation coefficients for constructing the boundary conditions at grid interfaces of the overset grid are developed and implemented using efficient parallel computing communication strategies to transfer information among sub-domains. The governing equations are discretized using a second-order accurate finite-volume approach and integrated in time via an efficient fractional-step method. Various strategies for ensuring globally conservative interpolation at grid interfaces suitable for incompressible flow fractional step methods are implemented and evaluated. The method is verified and validated against experimental data, and its capabilities are demonstrated by simulating the flow past multiple aquatic swimmers and the systolic flow in an anatomic left ventricle with a mechanical heart valve implanted in the aortic position. PMID:23833331
A Wireless Interface for Replacing the Cables in Bridge-Sensor Applications
Pavlin, Marko; Novak, Franc
2012-01-01
This paper presents a solution in which a wireless interface is employed to replace the cables in bridge-sensor measurement applications. The most noticeable feature of the presented approach is the fact that the wireless interface simply replaces the cables without any additional hardware modification to the existing system. In this approach, the concept of reciprocal topology is employed, where the transmitter side acquires signals with its own transfer function and the receiver side reconstructs them with the transfer function reciprocal to the transmitter transfer function. In this paper the principle of data acquisition and reconstruction is described together with the implementation details of the signal transfer from the sensor to the signal-monitoring equipment. The wireless data communication was investigated and proprietary data-reduction methods were developed. The proposed methods and algorithms were implemented using two different wireless technologies. The performance was evaluated with a dedicated data-acquisition system and finally, the test results were analyzed. The two different sets of results indicated the high level of amplitude and the temporal accuracy of the wirelessly transferred sensor signals. PMID:23112585
NASA Technical Reports Server (NTRS)
Bowles, Kenneth J.
1992-01-01
To date, the effect of thermo-oxidative aging on unidirectional composite mechanical properties has been monitored by the measurement of interlaminar shear strength (ILSS) and either three or four point longitudinal flexural strength (LFS) of the composites being tested. Both results are affected by the fiber-to-matrix bonding, the former being dependent on the shear resistance of the interface and the latter on the degree of load sharing by the fibers through the fiber/matrix interface. Recently, fiber/matrix interfacial bond strengths have been monitored using a transverse flexural strength (TFS) test method. This test method was used to evaluate the effect of fiber surface treatment on the fiber/matrix bond. The interface bonding was varied in these tests using Hercules A-fibers with three-types of surfaces that produce bonds of poor, better, and good quality. The TFS was found not only to be sensitive to the bonding, but also to the aging time of unidirectional A-fiber/PMR-15 composites. This relationship reflects the mechanism by which the PMR-15 degrades during thermal aging.
Cakan, Umut; Cakan, Murat; Delilbasi, Cagri
2016-01-01
The aim of this investigation was to measure the temperature increase due to heat transferred to the implant-bone interface when the abutment screw channel is accessed or a metal-ceramic crown is sectioned buccally with diamond or tungsten carbide bur using an air rotor, with or without irrigation. Cobalt-chromium copings were cemented onto straight titanium abutments. The temperature changes during removal of the copings were recorded over a period of 1 minute. The sectioning of coping with diamond bur and without water irrigation generated the highest temperature change at the cervical part of the implant. Both crown removal methods resulted in an increase in temperature at the implant-bone interface. However, this temperature change did not exceed 47°C, the potentially damaging threshold for bone reported in the literature.
Labview Interface Concepts Used in NASA Scientific Investigations and Virtual Instruments
NASA Technical Reports Server (NTRS)
Roth, Don J.; Parker, Bradford H.; Rapchun, David A.; Jones, Hollis H.; Cao, Wei
2001-01-01
This article provides an overview of several software control applications developed for NASA using LabVIEW. The applications covered here include (1) an Ultrasonic Measurement System for nondestructive evaluation of advanced structural materials, an Xray Spectral Mapping System for characterizing the quality and uniformity of developing photon detector materials, (2) a Life Testing System for these same materials, (3) and the instrument panel for an aircraft mounted Cloud Absorption Radiometer that measures the light scattered by clouds in multiple spectral bands. Many of the software interface concepts employed are explained. Panel layout and block diagram (code) strategies for each application are described. In particular, some of the more unique features of the applications' interfaces and source code are highlighted. This article assumes that the reader has a beginner-to-intermediate understanding of LabVIEW methods.
Introduction to optical methods for characterizing liquid crystals at interfaces.
Miller, Daniel S; Carlton, Rebecca J; Mushenheim, Peter C; Abbott, Nicholas L
2013-03-12
This Instructional Review describes methods and underlying principles that can be used to characterize both the orientations assumed spontaneously by liquid crystals (LCs) at interfaces and the strength with which the LCs are held in those orientations (so-called anchoring energies). The application of these methods to several different classes of LC interfaces is described, including solid and aqueous interfaces as well as planar and nonplanar interfaces (such as those that define a LC-in-water emulsion droplet). These methods, which enable fundamental studies of the ordering of LCs at polymeric, chemically functionalized, and biomolecular interfaces, are described in this Instructional Review on a level that can be easily understood by a nonexpert reader such as an undergraduate or graduate student. We focus on optical methods because they are based on instrumentation that is found widely in research and teaching laboratories.
Research interface on a programmable ultrasound scanner.
Shamdasani, Vijay; Bae, Unmin; Sikdar, Siddhartha; Yoo, Yang Mo; Karadayi, Kerem; Managuli, Ravi; Kim, Yongmin
2008-07-01
Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. The developed research interface can aid researchers in the rapid testing and clinical evaluation of new ultrasound algorithms and applications. Additionally, we believe that our approach would be applicable to designing research interfaces on other ultrasound machines.
Conceptualization and application of an approach for designing healthcare software interfaces.
Kumar, Ajit; Maskara, Reena; Maskara, Sanjeev; Chiang, I-Jen
2014-06-01
The aim of this study is to conceptualize a novel approach, which facilitates us to design prototype interfaces for healthcare software. Concepts and techniques from various disciplines were used to conceptualize an interface design approach named MORTARS (Map Original Rhetorical To Adapted Rhetorical Situation). The concepts and techniques included in this approach are (1) rhetorical situation - a concept of philosophy provided by Bitzer (1968); (2) move analysis - an applied linguistic technique provided by Swales (1990) and Bhatia (1993); (3) interface design guidelines - a cognitive and computer science concept provided by Johnson (2010); (4) usability evaluation instrument - an interface evaluation questionnaire provided by Lund (2001); (5) user modeling via stereotyping - a cognitive and computer science concept provided by Rich (1979). A prototype interface for outpatient clinic software was designed to introduce the underlying concepts of MORTARS. The prototype interface was evaluated by thirty-two medical informaticians. The medical informaticians found the designed prototype interface to be useful (73.3%), easy to use (71.9%), easy to learn (93.1%), and satisfactory (53.2%). MORTARS approach was found to be effective in designing the prototype user interface for the outpatient clinic software. This approach might be further used to design interfaces for various software pertaining to healthcare and other domains. Copyright © 2014 Elsevier Inc. All rights reserved.
2000-05-21
High School Chemistry teacher, for my first thorough appreciation and fine immersion in the scientific method. Mrs. Linda Giffin, Eleventh-Grade...Scott Renner, and Len Seligman . 1997. A consumer viewpoint on `mediator languages -- a proposal for a standard`. SIGMOD Record 26, no. 1: 45-46. http
Electroacoustic Evaluation of Frequency-Modulated Receivers Interfaced with Personal Hearing Aids
ERIC Educational Resources Information Center
Schafer, Erin C.; Thibodeau, Linda M.; Whalen, Holly S.; Overson, Gary J.
2007-01-01
Purpose: The purpose of this study was to compare the electroacoustic outputs of frequency-modulated (FM) systems coupled to hearing aids. Method: Electroacoustic performance of FM systems coupled to hearing aids was determined for 3 FM receivers: body-worn with neck loop, ear-level nonprogrammable, and ear-level programmable. Systems were…
FirstSearch and NetFirst--Web and Dial-up Access: Plus Ca Change, Plus C'est la Meme Chose?
ERIC Educational Resources Information Center
Koehler, Wallace; Mincey, Danielle
1996-01-01
Compares and evaluates the differences between OCLC's dial-up and World Wide Web FirstSearch access methods and their interfaces with the underlying databases. Also examines NetFirst, OCLC's new Internet catalog, the only Internet tracking database from a "traditional" database service. (Author/PEN)
ERIC Educational Resources Information Center
Dolan, Robert P.; Burling, Kelly; Harms, Michael; Strain-Seymour, Ellen; Way, Walter; Rose, David H.
2013-01-01
The increased capabilities offered by digital technologies offer new opportunities to evaluate students' deeper knowledge and skills and on constructs that are difficult to measure using traditional methods. Such assessments can also incorporate tools and interfaces that improve accessibility for diverse students, as well as inadvertently…
The final session of the workshop considered the subject of software technology and how it might be better constructed to support those who develop, evaluate, and apply multimedia environmental models. Two invited presentations were featured along with an extended open discussio...
Continuation of research into software for space operations support, volume 1
NASA Technical Reports Server (NTRS)
Collier, Mark D.; Killough, Ronnie; Martin, Nancy L.
1990-01-01
A prototype workstation executive called the Hardware Independent Software Development Environment (HISDE) was developed. Software technologies relevant to workstation executives were researched and evaluated and HISDE was used as a test bed for prototyping efforts. New X Windows software concepts and technology were introduced into workstation executives and related applications. The four research efforts performed included: (1) Research into the usability and efficiency of Motif (an X Windows based graphic user interface) which consisted of converting the existing Athena widget based HISDE user interface to Motif demonstrating the usability of Motif and providing insight into the level of effort required to translate an application from widget to another; (2) Prototype a real time data display widget which consisted of research methods for and prototyping the selected method of displaying textual values in an efficient manner; (3) X Windows performance evaluation which consisted of a series of performance measurements which demonstrated the ability of low level X Windows to display textural information; (4) Convert the Display Manager to X Window/Motif which is the application used by NASA for data display during operational mode.
Shultz, Mary
2006-01-01
Introduction: Given the common use of acronyms and initialisms in the health sciences, searchers may be entering these abbreviated terms rather than full phrases when searching online systems. The purpose of this study is to evaluate how various MEDLINE Medical Subject Headings (MeSH) interfaces map acronyms and initialisms to the MeSH vocabulary. Methods: The interfaces used in this study were: the PubMed MeSH database, the PubMed Automatic Term Mapping feature, the NLM Gateway Term Finder, and Ovid MEDLINE. Acronyms and initialisms were randomly selected from 2 print sources. The test data set included 415 randomly selected acronyms and initialisms whose related meanings were found to be MeSH terms. Each acronym and initialism was entered into each MEDLINE MeSH interface to determine if it mapped to the corresponding MeSH term. Separately, 46 commonly used acronyms and initialisms were tested. Results: While performance differed widely, the success rates were low across all interfaces for the randomly selected terms. The common acronyms and initialisms tested at higher success rates across the interfaces, but the differences between the interfaces remained. Conclusion: Online interfaces do not always map medical acronyms and initialisms to their corresponding MeSH phrases. This may lead to inaccurate results and missed information if acronyms and initialisms are used in search strategies. PMID:17082832
A Safety Index and Method for Flightdeck Evaluation
NASA Technical Reports Server (NTRS)
Latorella, Kara A.
2000-01-01
If our goal is to improve safety through machine, interface, and training design, then we must define a metric of flightdeck safety that is usable in the design process. Current measures associated with our notions of "good" pilot performance and ultimate safety of flightdeck performance fail to provide an adequate index of safe flightdeck performance for design evaluation purposes. The goal of this research effort is to devise a safety index and method that allows us to evaluate flightdeck performance holistically and in a naturalistic experiment. This paper uses Reason's model of accident causation (1990) as a basis for measuring safety, and proposes a relational database system and method for 1) defining a safety index of flightdeck performance, and 2) evaluating the "safety" afforded by flightdeck performance for the purpose of design iteration. Methodological considerations, limitations, and benefits are discussed as well as extensions to this work.
NASA Technical Reports Server (NTRS)
Tobey, G. L.
1978-01-01
Tests were performed to evaluate the operating characteristics of the interface between the Space Lab Bus Interface Unit (SL/BIU) and the Orbiter Multiplexer-Demultiplexer (MDM) serial data input-output (SIO) module. This volume contains the test equipment preparation procedures and a detailed description of the Nova/Input Output Processor Simulator (IOPS) software used during the data transfer tests to determine word error rates (WER).
Hybrid method for moving interface problems with application to the Hele-Shaw flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, T.Y.; Li, Zhilin; Osher, S.
In this paper, a hybrid approach which combines the immersed interface method with the level set approach is presented. The fast version of the immersed interface method is used to solve the differential equations whose solutions and their derivatives may be discontinuous across the interfaces due to the discontinuity of the coefficients or/and singular sources along the interfaces. The moving interfaces then are updated using the newly developed fast level set formulation which involves computation only inside some small tubes containing the interfaces. This method combines the advantage of the two approaches and gives a second-order Eulerian discretization for interfacemore » problems. Several key steps in the implementation are addressed in detail. This new approach is then applied to Hele-Shaw flow, an unstable flow involving two fluids with very different viscosity. 40 refs., 10 figs., 3 tabs.« less
Residual interface tensile strength of ceramic bonded to dentin after cyclic loading and aging.
Hernandez, Alfredo I; Roongruangphol, Thasanai; Katsube, Noriko; Seghi, Robert R
2008-03-01
To guard against the potential risk of cusp fracture, esthetic onlay restorations have been advocated for teeth with large restorations. The influence of the adhesive resin cement is believed to play a role in strengthening these restorations. The durability of this tooth/adhesive/ceramic interface is critical to ensure clinical longevity. The purpose of this study was to assess the effects of cyclic loading and environmental aging on the residual interface strength of a ceramic bonded to dentin structure. Eighteen simple trilayer specimens were fabricated, consisting of a 1.5-mm-thick ceramic plate (ProCAD) bonded to a flattened human molar tooth with exposed coronal dentin. The ceramic plates were bonded using resin cement (Nexus 2) and manufacturer-recommended bonding techniques. The specimens were divided into 3 equal groups and were stored in water at 37 degrees C for 10 weeks as a control group (CT), 9 months as an aging group (AG), or placed in water at 37 degrees C while being subjected to 10 million vertical loading cycles between 20 N to 200 N, as a fatigue group (FG). After the specimens were subjected to the experimental conditions, they were sectioned perpendicular to the flat ceramic surface into 1 x 1-mm sticks. The mean residual interface microtensile bond (MTB) strength was determined for each specimen using only those sticks which contained ceramic bonded to dentin. The MTB strength data were analyzed using Weibull analysis methods to determine differences between groups. All subsequent failed specimen surfaces were evaluated under a stereomicroscope at x10 magnification to determine the apparent failure modes. Some specimens were selected from each failure mode category for surface evaluation under a scanning electron microscope (SEM). The characteristic Weibull means for the 3 groups were CT, 19.2, FG, 14.7, and AG, 11.7. The bond strength of group CT was significantly greater than both AG (P=.007) and FG (P=.014). Light microscopic categorization of the failure modes suggests that adhesive failure at the ceramic/cement interface was the most common (65%) for all 3 groups. SEM evaluation of failed surfaces of select specimens from each group could not distinguish any interface appearance differences. For indirect adhesive-retained ceramic restorations, both cyclic masticatory loading and hydrolytic degradation may contribute to a weakening of the interface bond. The ceramic/resin interface may be more susceptible to these changes over the time frame of this investigation than the dentin/resin interface.
Health Care Robotics: A Progress Report
NASA Technical Reports Server (NTRS)
Fiorini, Paolo; Ali, Khaled; Seraji, Homayoun
1997-01-01
This paper describes the approach followed in the design of a service robot for health care applications. Under the auspices of the NASA Technology Transfer program, a partnership was established between JPL and RWI, a manufacturer of mobile robots, to design and evaluate a mobile robot for health care assistance to the elderly and the handicapped. The main emphasis of the first phase of the project is on the development on a multi-modal operator interface and its evaluation by health care professionals and users. This paper describes the architecture of the system, the evaluation method used, and some preliminary results of the user evaluation.
NASA Astrophysics Data System (ADS)
Sekiguchi, Atsuko; Koike, Junichi
2008-01-01
Mechanical processes of the nanoscratch test are investigated using a finite element analysis of Cu/Ta/SiO2/Si multilayer films. The calculated stress distribution at the moment of delamination suggests that delamination occurs in a small region of approximately 100 nm. The driving force for delamination is the stress concentration due to strain-incompatibility at the Cu/Ta interface resulting from the large plastic deformation in Cu. The degree of stress concentration is found to depend on internal variables, such as plastic deformation, residual stress, and the elastic modulus, and on the magnitude of lateral force.
Mixed-Mode Decohesion Elements for Analyses of Progressive Delamination
NASA Technical Reports Server (NTRS)
Davila, Carlos G.; Camanho, Pedro P.; deMoura, Marcelo F.
2001-01-01
A new 8-node decohesion element with mixed mode capability is proposed and demonstrated. The element is used at the interface between solid finite elements to model the initiation and propagation of delamination. A single displacement-based damage parameter is used in a strain softening law to track the damage state of the interface. The method can be used in conjunction with conventional material degradation procedures to account for inplane and intra-laminar damage modes. The accuracy of the predictions is evaluated in single mode delamination tests, in the mixed-mode bending test, and in a structural configuration consisting of the debonding of a stiffener flange from its skin.
Active skin as new haptic interface
NASA Astrophysics Data System (ADS)
Vuong, Nguyen Huu Lam; Kwon, Hyeok Yong; Chuc, Nguyen Huu; Kim, Duksang; An, Kuangjun; Phuc, Vuong Hong; Moon, Hyungpil; Koo, Jachoon; Lee, Youngkwan; Nam, Jae-Do; Choi, Hyouk Ryeol
2010-04-01
In this paper, we present a new haptic interface, called "active skin", which is configured with a tactile sensor and a tactile stimulator in single haptic cell, and multiple haptic cells are embedded in a dielectric elastomer. The active skin generates a wide variety of haptic feel in response to the touch by synchronizing the sensor and the stimulator. In this paper, the design of the haptic cell is derived via iterative analysis and design procedures. A fabrication method dedicated to the proposed device is investigated and a controller to drive multiple haptic cells is developed. In addition, several experiments are performed to evaluate the performance of the active skin.
Evaluation of the adhesion on the nano-scaled polymeric film systems.
Park, Tae Sung; Park, Ik Keun; Yoshida, Sanichiro
2017-04-01
We applied scanning acoustic microscopy known as the V(z) curve technique to photoresist thin-film systems for the evaluation of the adhesive strength at the film-substrate interface. Through the measurement of the SAW (Surface Acoustic Wave) velocity, the V(z) curve analysis allows us to quantify the stiffness of the film-substrate interface. In addition, we conducted a nano-scratch test to quantify the ultimate strength of the adhesion through the evaluation of the critical load. To vary the adhesive conditions, we prepared thin-film specimens with three different types of pre-coating surface treatments, i.e., oxygen-plasma bombardment, HMDS (Hexametyldisilazane) treatment and untreated. The magnitudes of the quantified stiffness and ultimate strength are found consistent with each other for all the specimens tested, indicating that the pre-coating surface treatment can strengthen both the stiffness and ultimate strength of the adhesion. The results of this study demonstrate the usefulness of the V(Z) analysis as a nondestructive method to evaluate the adhesion strength of nano-structured thin-film systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Miller, Daniel S.; Carlton, Rebecca J.; Mushenheim, Peter C.; Abbott, Nicholas L.
2013-01-01
This Instructional Review describes methods and underlying principles that can be used to characterize both the orientations assumed spontaneously by liquid crystals (LCs) at interfaces and the strength with which the LCs are held in those orientations (so-called anchoring energies). The application of these methods to several different classes of LC interfaces is described, including solid and aqueous interfaces as well as planar and non-planar interfaces (such as those that define a LC-in-water emulsion droplet). These methods, which enable fundamental studies of the ordering of LCs at polymeric, chemically-functionalized and biomolecular interfaces, are described in this article at a level that can be easily understood by a non-expert reader such as an undergraduate or graduate student. We focus on optical methods because they are based on instrumentation that is found widely in research and teaching laboratories. PMID:23347378
Visual exploration and analysis of human-robot interaction rules
NASA Astrophysics Data System (ADS)
Zhang, Hui; Boyles, Michael J.
2013-01-01
We present a novel interaction paradigm for the visual exploration, manipulation and analysis of human-robot interaction (HRI) rules; our development is implemented using a visual programming interface and exploits key techniques drawn from both information visualization and visual data mining to facilitate the interaction design and knowledge discovery process. HRI is often concerned with manipulations of multi-modal signals, events, and commands that form various kinds of interaction rules. Depicting, manipulating and sharing such design-level information is a compelling challenge. Furthermore, the closed loop between HRI programming and knowledge discovery from empirical data is a relatively long cycle. This, in turn, makes design-level verification nearly impossible to perform in an earlier phase. In our work, we exploit a drag-and-drop user interface and visual languages to support depicting responsive behaviors from social participants when they interact with their partners. For our principal test case of gaze-contingent HRI interfaces, this permits us to program and debug the robots' responsive behaviors through a graphical data-flow chart editor. We exploit additional program manipulation interfaces to provide still further improvement to our programming experience: by simulating the interaction dynamics between a human and a robot behavior model, we allow the researchers to generate, trace and study the perception-action dynamics with a social interaction simulation to verify and refine their designs. Finally, we extend our visual manipulation environment with a visual data-mining tool that allows the user to investigate interesting phenomena such as joint attention and sequential behavioral patterns from multiple multi-modal data streams. We have created instances of HRI interfaces to evaluate and refine our development paradigm. As far as we are aware, this paper reports the first program manipulation paradigm that integrates visual programming interfaces, information visualization, and visual data mining methods to facilitate designing, comprehending, and evaluating HRI interfaces.
Shin, Younghak; Lee, Seungchan; Ahn, Minkyu; Cho, Hohyun; Jun, Sung Chan; Lee, Heung-No
2015-11-01
One of the main problems related to electroencephalogram (EEG) based brain-computer interface (BCI) systems is the non-stationarity of the underlying EEG signals. This results in the deterioration of the classification performance during experimental sessions. Therefore, adaptive classification techniques are required for EEG based BCI applications. In this paper, we propose simple adaptive sparse representation based classification (SRC) schemes. Supervised and unsupervised dictionary update techniques for new test data and a dictionary modification method by using the incoherence measure of the training data are investigated. The proposed methods are very simple and additional computation for the re-training of the classifier is not needed. The proposed adaptive SRC schemes are evaluated using two BCI experimental datasets. The proposed methods are assessed by comparing classification results with the conventional SRC and other adaptive classification methods. On the basis of the results, we find that the proposed adaptive schemes show relatively improved classification accuracy as compared to conventional methods without requiring additional computation. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Fry, P. E.
1993-06-01
A limited evaluation was made of two commonly found microwave interconnections: microstrip-to-microstrip and coaxial-to-microstrip. The evaluation attempted to select the interconnection technique which worked best for the particular interface type. Short ribbon wires worked best for the microstrip-to-microstrip interconnection. A published method of compensating the microstrip conductor had the best performance for the coaxial-to-microstrip interconnection. The work was conducted under the Microwave Technology Process Capability Assurance Program at Allied-Signal Inc., Kansas City Division.
NASA Technical Reports Server (NTRS)
Arthur, Jarvis J., III; Shelton, Kevin J.; Prinzel, Lawrence J., III; Bailey, Randall E.
2016-01-01
During the flight trials known as Gulfstream-V Synthetic Vision Systems Integrated Technology Evaluation (GV-SITE), a Speech Recognition System (SRS) was used by the evaluation pilots. The SRS system was intended to be an intuitive interface for display control (rather than knobs, buttons, etc.). This paper describes the performance of the current "state of the art" Speech Recognition System (SRS). The commercially available technology was evaluated as an application for possible inclusion in commercial aircraft flight decks as a crew-to-vehicle interface. Specifically, the technology is to be used as an interface from aircrew to the onboard displays, controls, and flight management tasks. A flight test of a SRS as well as a laboratory test was conducted.
NASA Astrophysics Data System (ADS)
Streza, M.; Hodisan, I.; Prejmerean, C.; Boue, C.; Tessier, Gilles
2015-03-01
The evaluation of a dental restoration in a non-invasive way is of paramount importance in clinical practice. The aim of this study was to assess the minimum detectable open crack at the cavity-restorative material interface by the lock-in thermography technique, at laser intensities which are safe for living teeth. For the analysis of the interface, 18 box-type class V standardized cavities were prepared on the facial and oral surfaces of each tooth, with coronal margins in enamel and apical margins in dentine. The preparations were restored with the Giomer Beautifil (Shofu) in combination with three different adhesive systems. Three specimens were randomly selected from each experimental group and each slice has been analysed by visible, infrared (IR), and scanning electron microscopy (SEM). Lock-in thermography showed the most promising results in detecting both marginal and internal defects. The proposed procedure leads to a diagnosis of micro-leakages having openings of 1 µm, which is close to the diffraction limit of the IR camera. Clinical use of a thermographic camera in assessing the marginal integrity of a restoration becomes possible. The method overcomes some drawbacks of standard SEM or dye penetration testing. The results support the use of an IR camera in dentistry, for the diagnosis of micro-gaps at bio-interfaces.
MIB Galerkin method for elliptic interface problems.
Xia, Kelin; Zhan, Meng; Wei, Guo-Wei
2014-12-15
Material interfaces are omnipresent in the real-world structures and devices. Mathematical modeling of material interfaces often leads to elliptic partial differential equations (PDEs) with discontinuous coefficients and singular sources, which are commonly called elliptic interface problems. The development of high-order numerical schemes for elliptic interface problems has become a well defined field in applied and computational mathematics and attracted much attention in the past decades. Despite of significant advances, challenges remain in the construction of high-order schemes for nonsmooth interfaces, i.e., interfaces with geometric singularities, such as tips, cusps and sharp edges. The challenge of geometric singularities is amplified when they are associated with low solution regularities, e.g., tip-geometry effects in many fields. The present work introduces a matched interface and boundary (MIB) Galerkin method for solving two-dimensional (2D) elliptic PDEs with complex interfaces, geometric singularities and low solution regularities. The Cartesian grid based triangular elements are employed to avoid the time consuming mesh generation procedure. Consequently, the interface cuts through elements. To ensure the continuity of classic basis functions across the interface, two sets of overlapping elements, called MIB elements, are defined near the interface. As a result, differentiation can be computed near the interface as if there is no interface. Interpolation functions are constructed on MIB element spaces to smoothly extend function values across the interface. A set of lowest order interface jump conditions is enforced on the interface, which in turn, determines the interpolation functions. The performance of the proposed MIB Galerkin finite element method is validated by numerical experiments with a wide range of interface geometries, geometric singularities, low regularity solutions and grid resolutions. Extensive numerical studies confirm the designed second order convergence of the MIB Galerkin method in the L ∞ and L 2 errors. Some of the best results are obtained in the present work when the interface is C 1 or Lipschitz continuous and the solution is C 2 continuous.
Eddy current sensor concepts for the Bridgman growth of semiconductors
NASA Astrophysics Data System (ADS)
Dharmasena, Kumar P.; Wadley, Haydn N. G.
1997-03-01
Electromagnetic finite element methods have been used to identify eddy current sensor designs for monitoring CdTe vertical Bridgman crystal growth. A model system consisting of pairs of silicon cylinders with electrical conductivities similar to those of solid and liquid CdTe has been used to evaluate the multifrequency response of several sensors designed for locating and characterizing the curvature of liquid-solid interfaces during vertical Bridgman growth. At intermediate frequencies (100-800 kHz), the sensor's imaginary impedance monotonically increases as interfacial curvature changes from concave to convex or the interface location moves upwards through the sensor. The experimental data are in excellent agreement with theoretical predictions. At higher test frequencies (˜ 5 MHz), the test circuit's parasitics contribute to the sensor's response. Even so, the predicted trends with interface location/curvature were found to be still preserved, and the experiments confirm that the sensor's high frequency response depends more on interface location and has only a small sensitivity to curvature. Multifrequency data obtained from these types of sensors have the potential to separately discriminate the location and the shape of liquid-solid interfaces during the vertical Bridgman growth of CdTe and other semiconductor materials of higher electrical conductivity.
Kabel, Joey; Hosemann, Peter; Zayachuk, Yevhen; ...
2018-01-24
We present that ceramic fiber–matrix composites (CFMCs) are exciting materials for engineering applications in extreme environments. By integrating ceramic fibers within a ceramic matrix, CFMCs allow an intrinsically brittle material to exhibit sufficient structural toughness for use in gas turbines and nuclear reactors. Chemical stability under high temperature and irradiation coupled with high specific strength make these materials unique and increasingly popular in extreme settings. This paper first offers a review of the importance and growing body of research on fiber–matrix interfaces as they relate to composite toughening mechanisms. Second, micropillar compression is explored experimentally as a high-fidelity method formore » extracting interface properties compared with traditional fiber push-out testing. Three significant interface properties that govern composite toughening were extracted. For a 50-nm-pyrolytic carbon interface, the following were observed: a fracture energy release rate of ~2.5 J/m 2, an internal friction coefficient of 0.25 ± 0.04, and a debond shear strength of 266 ± 24 MPa. Lastly, this research supports micromechanical evaluations as a unique bridge between theoretical physics models for microcrack propagation and empirically driven finite element models for bulk CFMCs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandt, Riley E.; Mangan, Niall M.; Li, Jian V.
The development of new thin-film photovoltaic (PV) absorbers is often hindered by the search for an optimal heterojunction contact; an unoptimized contact may be mistaken for poor quality of the underlying absorber, making it difficult to assess the reasons for poor performance. Therefore, quantifying the loss in device efficiency and open-circuit voltage (VOC) as a result of the interface is a critical step in evaluating a new material. In the present work, we fabricate thin-film PV devices using cuprous oxide (Cu2O), with several different n-type heterojunction contacts. Their current-voltage characteristics are measured over a range of temperatures and illumination intensitiesmore » (JVTi). We quantify the loss in VOC due to the interface and determine the effective energy gap at the interface. The effective interface gap measured by JVTi matches the gap measured by X-ray photoelectron spectroscopy, albeit with higher energy resolution and an order of magnitude faster. We discuss potential artifacts in JVTi measurements and areas where analytical models are insufficient. Applying JVTi to complete devices, rather than incomplete material stacks, suggests that it can be a quick, accurate method to assess the loss due to unoptimized interface band offsets in thin-film PV devices.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kabel, Joey; Hosemann, Peter; Zayachuk, Yevhen
We present that ceramic fiber–matrix composites (CFMCs) are exciting materials for engineering applications in extreme environments. By integrating ceramic fibers within a ceramic matrix, CFMCs allow an intrinsically brittle material to exhibit sufficient structural toughness for use in gas turbines and nuclear reactors. Chemical stability under high temperature and irradiation coupled with high specific strength make these materials unique and increasingly popular in extreme settings. This paper first offers a review of the importance and growing body of research on fiber–matrix interfaces as they relate to composite toughening mechanisms. Second, micropillar compression is explored experimentally as a high-fidelity method formore » extracting interface properties compared with traditional fiber push-out testing. Three significant interface properties that govern composite toughening were extracted. For a 50-nm-pyrolytic carbon interface, the following were observed: a fracture energy release rate of ~2.5 J/m 2, an internal friction coefficient of 0.25 ± 0.04, and a debond shear strength of 266 ± 24 MPa. Lastly, this research supports micromechanical evaluations as a unique bridge between theoretical physics models for microcrack propagation and empirically driven finite element models for bulk CFMCs.« less
Operator Performance Evaluation of Fault Management Interfaces for Next-Generation Spacecraft
NASA Technical Reports Server (NTRS)
Hayashi, Miwa; Ravinder, Ujwala; Beutter, Brent; McCann, Robert S.; Spirkovska, Lilly; Renema, Fritz
2008-01-01
In the cockpit of the NASA's next generation of spacecraft, most of vehicle commanding will be carried out via electronic interfaces instead of hard cockpit switches. Checklists will be also displayed and completed on electronic procedure viewers rather than from paper. Transitioning to electronic cockpit interfaces opens up opportunities for more automated assistance, including automated root-cause diagnosis capability. The paper reports an empirical study evaluating two potential concepts for fault management interfaces incorporating two different levels of automation. The operator performance benefits produced by automation were assessed. Also, some design recommendations for spacecraft fault management interfaces are discussed.
Solvent Flux Method (SFM): A Case Study of Water Access to Candida antarctica Lipase B.
Benson, Sven P; Pleiss, Jürgen
2014-11-11
The solvent flux method (SFM) was developed to comprehensively characterize the influx of solvent molecules from the solvent environment into the active site of a protein in the framework of molecular dynamics simulations. This was achieved by introducing a solvent concentration gradient as well as partially reorienting and rescaling the velocity vector of all solvent molecules contained within a spherical volume enclosing the protein, thus inducing an accelerated solvent influx toward the active site. In addition to the detection of solvent access pathway within the protein structure, it is hereby possible to identify potential amino acid positions relevant to solvent-related enzyme engineering with high statistical significance. The method is particularly aimed at improving the reverse hydrolysis reaction rates in nonaqueous media. Candida antarctica lipase B (CALB) binds to a triglyceride-water interface with its substrate entrance channel oriented toward the hydrophobic substrate interface. The lipase-triglyceride-water system served as a model system for SFM to evaluate the influx of water molecules to the active site. As a proof of principle for SFM, a previously known water access pathway in CALB was identified as the primary water channel. In addition, a secondary water channel and two pathways for water access which contribute to water leakage between the protein and the triglyceride-water interface were identified.
Data acquisition system for chemical kinetic studies
Zhu, Yu-zhen; Zhou, Xin; Zang, Xiang-sheng
1989-01-01
A microcomputer-interfaced data acquisition system for chemical kinetics (interfacing with laboratory analogue instruments) has been developed. Analogue signals from instruments used in kinetics experiments are amplifed by a wide-range adjustable high-gain operational amplifier and smoothed by an op-based filter, and then digitized at rates of up to 104 samples per channel by an ADC 0816 digitizer. The ADC data transfer and manipulation routine was written in Assembler code and in high-level language; the graphics package and data treatment package is in Basic. For the various sampling speeds, all of the program can be written using Basic-Assembler or completely in Assembler if a high sampling rate is needed. Several numerical treatment methods for chemical kinetics have been utilized to smooth the data from experiments. The computer-interfaced system for second-order chemical kinetic studies was applied to the determination of the rate constant of the saponification of ethyl acetate at 35°C. For this specific problem, an averaging treatment was used which can be called an interval method. The use of this method avoids the diffcully of measuring the starting time of the reaction. Two groups of experimental data and results were used to evaluate the systems performance. All of the results obtained are in agreement with the reference value. PMID:18925219
The effect of ligation method on friction in sliding mechanics.
Hain, Max; Dhopatkar, Ashish; Rock, Peter
2003-04-01
During orthodontic tooth movement with the preadjusted edgewise system, friction generated at the bracket/archwire interface tends to impede the desired movement. The method of ligation is an important contributor to this frictional force. This in vitro study investigated the effect of ligation method on friction and evaluated the efficacy of the new slick elastomeric modules from TP Orthodontics (La Porte, Ind), which are claimed to reduce friction at the module/wire interface. Slick modules were compared with regular nonslick modules, stainless steel ligatures, and the SPEED self-ligating bracket system (Strite Industries, Cambridge, Ontario, Canada). The effect of using slick modules with metal-reinforced ceramic (Clarity, 3M Unitek, Monrovia, Calif) and miniature brackets (Minitwin, 3M Unitek) was also examined. Results showed that, when considering tooth movement along a 0.019 x 0.025-in stainless steel archwire, saliva-lubricated slick modules can reduce static friction at the module/archwire interface by up to 60%, regardless of the bracket system. The SPEED brackets produced the lowest friction compared with the 3 other tested bracket systems when regular modules were used. The use of slick modules, however, with all of the ligated bracket types tested significantly reduced friction to below the values recorded in the SPEED groups. Loosely tied stainless steel ligatures were found to generate the least friction.
Gradient augmented level set method for phase change simulations
NASA Astrophysics Data System (ADS)
Anumolu, Lakshman; Trujillo, Mario F.
2018-01-01
A numerical method for the simulation of two-phase flow with phase change based on the Gradient-Augmented-Level-set (GALS) strategy is presented. Sharp capturing of the vaporization process is enabled by: i) identification of the vapor-liquid interface, Γ (t), at the subgrid level, ii) discontinuous treatment of thermal physical properties (except for μ), and iii) enforcement of mass, momentum, and energy jump conditions, where the gradients of the dependent variables are obtained at Γ (t) and are consistent with their analytical expression, i.e. no local averaging is applied. Treatment of the jump in velocity and pressure at Γ (t) is achieved using the Ghost Fluid Method. The solution of the energy equation employs the sub-grid knowledge of Γ (t) to discretize the temperature Laplacian using second-order one-sided differences, i.e. the numerical stencil completely resides within each respective phase. To carefully evaluate the benefits or disadvantages of the GALS approach, the standard level set method is implemented and compared against the GALS predictions. The results show the expected trend that interface identification and transport are predicted noticeably better with GALS over the standard level set. This benefit carries over to the prediction of the Laplacian and temperature gradients in the neighborhood of the interface, which are directly linked to the calculation of the vaporization rate. However, when combining the calculation of interface transport and reinitialization with two-phase momentum and energy, the benefits of GALS are to some extent neutralized, and the causes for this behavior are identified and analyzed. Overall the additional computational costs associated with GALS are almost the same as those using the standard level set technique.
Usability evaluation of in-housed developed ERP system
NASA Astrophysics Data System (ADS)
Faisal, Chaudhry Muhammad Nadeem; Shakeel Faridi, Muhammad; Javed, Zahid
2011-10-01
Enterprise Resource Planning systems are the combination of different business IS (Information System) applications that are designed according to the organization requirements. Generally ERP systems are suffering from complex user interface issues. Recent research shows that there is a need for improvement concerning, the user interface from their perspectives. In order to design the software applications that are easy to use, memorize and apply to new problems, we must know the users philosophy and something about learning, reminiscence and problems solving. The Usability engineering is the only way to study the deeds of users while interacting with ERP (Enterprise Resource & Planning). This paper will focus on the users' experiences view of financial module in ERP system. The HCI research method, explicitly survey questionnaire method was adopted to gather users understanding in order to evaluate the selected modules for in-housed ERP system. The study involved group of users from two industries, the results can not be generalized as a whole. The study was first time successfully applied Usability evaluation on in-housed ERP in local industry (Masood Textile Mills, Interloop Ltd) in Pakistan. The results may hopefully opened-up an area of research and methodology that could provide considerable further benefits to Industry in developments of Industrial information systems.
Balatsoukas, Panos; Williams, Richard; Davies, Colin; Ainsworth, John; Buchan, Iain
2015-11-01
Integrated care pathways (ICPs) define a chronological sequence of steps, most commonly diagnostic or treatment, to be followed in providing care for patients. Care pathways help to ensure quality standards are met and to reduce variation in practice. Although research on the computerisation of ICP progresses, there is still little knowledge on what are the requirements for designing user-friendly and usable electronic care pathways, or how users (normally health care professionals) interact with interfaces that support design, analysis and visualisation of ICPs. The purpose of the study reported in this paper was to address this gap by evaluating the usability of a novel web-based tool called COCPIT (Collaborative Online Care Pathway Investigation Tool). COCPIT supports the design, analysis and visualisation of ICPs at the population level. In order to address the aim of this study, an evaluation methodology was designed based on heuristic evaluations and a mixed method usability test. The results showed that modular visualisation and direct manipulation of information related to the design and analysis of ICPs is useful for engaging and stimulating users. However, designers should pay attention to issues related to the visibility of the system status and the match between the system and the real world, especially in relation to the display of statistical information about care pathways and the editing of clinical information within a care pathway. The paper concludes with recommendations for interface design.
Comparing Text-based and Graphic User Interfaces for Novice and Expert Users
Chen, Jung-Wei; Zhang, Jiajie
2007-01-01
Graphic User Interface (GUI) is commonly considered to be superior to Text-based User Interface (TUI). This study compares GUI and TUI in an electronic dental record system. Several usability analysis techniques compared the relative effectiveness of a GUI and a TUI. Expert users and novice users were evaluated in time required and steps needed to complete the task. A within-subject design was used to evaluate if the experience with either interface will affect task performance. The results show that the GUI interface was not better than the TUI for expert users. GUI interface was better for novice users. For novice users there was a learning transfer effect from TUI to GUI. This means a user interface is user-friendly or not depending on the mapping between the user interface and tasks. GUI by itself may or may not be better than TUI. PMID:18693811
Comparing Text-based and Graphic User Interfaces for novice and expert users.
Chen, Jung-Wei; Zhang, Jiajie
2007-10-11
Graphic User Interface (GUI) is commonly considered to be superior to Text-based User Interface (TUI). This study compares GUI and TUI in an electronic dental record system. Several usability analysis techniques compared the relative effectiveness of a GUI and a TUI. Expert users and novice users were evaluated in time required and steps needed to complete the task. A within-subject design was used to evaluate if the experience with either interface will affect task performance. The results show that the GUI interface was not better than the TUI for expert users. GUI interface was better for novice users. For novice users there was a learning transfer effect from TUI to GUI. This means a user interface is user-friendly or not depending on the mapping between the user interface and tasks. GUI by itself may or may not be better than TUI.
Pereira, Suzanne; Hassler, Sylvain; Hamek, Saliha; Boog, César; Leroy, Nicolas; Beuscart-Zéphir, Marie-Catherine; Favre, Madeleine; Venot, Alain; Duclos, Catherine; Lamy, Jean-Baptiste
2014-08-26
Clinical practice guidelines are useful for physicians, and guidelines are available on the Internet from various websites such as Vidal Recos. However, these guidelines are long and difficult to read, especially during consultation. Similar difficulties have been encountered with drug summaries of product characteristics. In a previous work, we have proposed an iconic language (called VCM, for Visualization of Concepts in Medicine) for representing patient conditions, treatments and laboratory tests, and we have used these icons to design a user interface that graphically indexes summaries of product characteristics. In the current study, our objective was to design and evaluate an iconic user interface for the consultation of clinical practice guidelines by physicians. Focus groups of physicians were set up to identify the difficulties encountered when reading guidelines. Icons were integrated into Vidal Recos, taking human factors into account. The resulting interface includes a graphical summary and an iconic indexation of the guideline. The new interface was evaluated. We compared the response times and the number of errors recorded when physicians answered questions about two clinical scenarios using the interactive iconic interface or a textual interface. Users' perceived usability was evaluated with the System Usability Scale. The main difficulties encountered by physicians when reading guidelines were obtaining an overview and finding recommendations for patients corresponding to "particular cases". We designed a graphical interface for guideline consultation, using icons to identify particular cases and providing a graphical summary of the icons organized by anatomy and etiology. The evaluation showed that physicians gave clinical responses more rapidly with the iconic interface than the textual interface (25.2 seconds versus 45.6, p < 0.05). The physicians appreciated the new interface, and the System Usability Scale score value was 75 (between good and excellent). An interactive iconic interface can provide physicians with an overview of clinical practice guidelines, and can decrease the time required to access the content of such guidelines.
Adaptive mesh refinement techniques for the immersed interface method applied to flow problems
Li, Zhilin; Song, Peng
2013-01-01
In this paper, we develop an adaptive mesh refinement strategy of the Immersed Interface Method for flow problems with a moving interface. The work is built on the AMR method developed for two-dimensional elliptic interface problems in the paper [12] (CiCP, 12(2012), 515–527). The interface is captured by the zero level set of a Lipschitz continuous function φ(x, y, t). Our adaptive mesh refinement is built within a small band of |φ(x, y, t)| ≤ δ with finer Cartesian meshes. The AMR-IIM is validated for Stokes and Navier-Stokes equations with exact solutions, moving interfaces driven by the surface tension, and classical bubble deformation problems. A new simple area preserving strategy is also proposed in this paper for the level set method. PMID:23794763
New Finite Difference Methods Based on IIM for Inextensible Interfaces in Incompressible Flows
Li, Zhilin; Lai, Ming-Chih
2012-01-01
In this paper, new finite difference methods based on the augmented immersed interface method (IIM) are proposed for simulating an inextensible moving interface in an incompressible two-dimensional flow. The mathematical models arise from studying the deformation of red blood cells in mathematical biology. The governing equations are incompressible Stokes or Navier-Stokes equations with an unknown surface tension, which should be determined in such a way that the surface divergence of the velocity is zero along the interface. Thus, the area enclosed by the interface and the total length of the interface should be conserved during the evolution process. Because of the nonlinear and coupling nature of the problem, direct discretization by applying the immersed boundary or immersed interface method yields complex nonlinear systems to be solved. In our new methods, we treat the unknown surface tension as an augmented variable so that the augmented IIM can be applied. Since finding the unknown surface tension is essentially an inverse problem that is sensitive to perturbations, our regularization strategy is to introduce a controlled tangential force along the interface, which leads to a least squares problem. For Stokes equations, the forward solver at one time level involves solving three Poisson equations with an interface. For Navier-Stokes equations, we propose a modified projection method that can enforce the pressure jump condition corresponding directly to the unknown surface tension. Several numerical experiments show good agreement with other results in the literature and reveal some interesting phenomena. PMID:23795308
Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang
2007-01-01
We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic (EOG) artifacts into individual components. An implementation of the selected BSS/ICA method with SVMs trained to classify EMG and EOG artifacts, which enables the usage of the method as a filter in measurements with online feedback, is described. This filter is evaluated on three BCI datasets as a proof-of-concept of the method. PMID:18288259
Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang
2007-01-01
We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic (EOG) artifacts into individual components. An implementation of the selected BSS/ICA method with SVMs trained to classify EMG and EOG artifacts, which enables the usage of the method as a filter in measurements with online feedback, is described. This filter is evaluated on three BCI datasets as a proof-of-concept of the method.
NASA Astrophysics Data System (ADS)
Bucha, Blažej; Janák, Juraj
2013-07-01
We present a novel graphical user interface program GrafLab (GRAvity Field LABoratory) for spherical harmonic synthesis (SHS) created in MATLAB®. This program allows to comfortably compute 38 various functionals of the geopotential up to ultra-high degrees and orders of spherical harmonic expansion. For the most difficult part of the SHS, namely the evaluation of the fully normalized associated Legendre functions (fnALFs), we used three different approaches according to required maximum degree: (i) the standard forward column method (up to maximum degree 1800, in some cases up to degree 2190); (ii) the modified forward column method combined with Horner's scheme (up to maximum degree 2700); (iii) the extended-range arithmetic (up to an arbitrary maximum degree). For the maximum degree 2190, the SHS with fnALFs evaluated using the extended-range arithmetic approach takes only approximately 2-3 times longer than its standard arithmetic counterpart, i.e. the standard forward column method. In the GrafLab, the functionals of the geopotential can be evaluated on a regular grid or point-wise, while the input coordinates can either be read from a data file or entered manually. For the computation on a regular grid we decided to apply the lumped coefficients approach due to significant time-efficiency of this method. Furthermore, if a full variance-covariances matrix of spherical harmonic coefficients is available, it is possible to compute the commission errors of the functionals. When computing on a regular grid, the output functionals or their commission errors may be depicted on a map using automatically selected cartographic projection.
A Finite Element Method for Simulation of Compressible Cavitating Flows
NASA Astrophysics Data System (ADS)
Shams, Ehsan; Yang, Fan; Zhang, Yu; Sahni, Onkar; Shephard, Mark; Oberai, Assad
2016-11-01
This work focuses on a novel approach for finite element simulations of multi-phase flows which involve evolving interface with phase change. Modeling problems, such as cavitation, requires addressing multiple challenges, including compressibility of the vapor phase, interface physics caused by mass, momentum and energy fluxes. We have developed a mathematically consistent and robust computational approach to address these problems. We use stabilized finite element methods on unstructured meshes to solve for the compressible Navier-Stokes equations. Arbitrary Lagrangian-Eulerian formulation is used to handle the interface motions. Our method uses a mesh adaptation strategy to preserve the quality of the volumetric mesh, while the interface mesh moves along with the interface. The interface jump conditions are accurately represented using a discontinuous Galerkin method on the conservation laws. Condensation and evaporation rates at the interface are thermodynamically modeled to determine the interface velocity. We will present initial results on bubble cavitation the behavior of an attached cavitation zone in a separated boundary layer. We acknowledge the support from Army Research Office (ARO) under ARO Grant W911NF-14-1-0301.
Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain
2018-01-01
Electronic audit and feedback (e-A&F) systems are used worldwide for care quality improvement. They measure health professionals' performance against clinical guidelines, and some systems suggest improvement actions. However, little is known about optimal interface designs for e-A&F, in particular how to present suggested actions for improvement. We developed a novel theory-informed system for primary care (the Performance Improvement plaN GeneratoR; PINGR) that covers the four principal interface components: clinical performance summaries; patient lists; detailed patient-level information; and suggested actions. As far as we are aware, this is the first report of an e-A&F system with all four interface components. (1) Use a combination of quantitative and qualitative methods to evaluate the usability of PINGR with target end-users; (2) refine existing design recommendations for e-A&F systems; (3) determine the implications of these recommendations for patient safety. We recruited seven primary care physicians to perform seven tasks with PINGR, during which we measured on-screen behaviour and eye movements. Participants subsequently completed usability questionnaires, and were interviewed in-depth. Data were integrated to: gain a more complete understanding of usability issues; enhance and explain each other's findings; and triangulate results to increase validity. Participants committed a median of 10 errors (range 8-21) when using PINGR's interface, and completed a median of five out of seven tasks (range 4-7). Errors violated six usability heuristics: clear response options; perceptual grouping and data relationships; representational formats; unambiguous description; visually distinct screens for confusable items; and workflow integration. Eye movement analysis revealed the integration of components largely supported effective user workflow, although the modular design of clinical performance summaries unnecessarily increased cognitive load. Interviews and questionnaires revealed PINGR is user-friendly, and that improved information prioritisation could further promote useful user action. Comparing our results with the wider usability literature we refine a previously published set of interface design recommendations for e-A&F. The implications for patient safety are significant regarding: user engagement; actionability; and information prioritisation. Our results also support adopting multi-method approaches in usability studies to maximise issue discovery and the credibility of findings. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
de Carvalho, Lilian Regina; Évora, Yolanda Dora Martinez; Zem-Mascarenhas, Silvia Helena
2016-01-01
ABSTRACT Objective: to assess the usability of a digital learning technology prototype as a new method for minimally invasive monitoring of intracranial pressure. Method: descriptive study using a quantitative approach on assessing the usability of a prototype based on Nielsen's ten heuristics. Four experts in the area of Human-Computer interaction participated in the study. Results: the evaluation delivered eight violated heuristics and 31 usability problems in the 32 screens of the prototype. Conclusion: the suggestions of the evaluators were critical for developing an intuitive, user-friendly interface and will be included in the final version of the digital learning technology. PMID:27579932
Intentional Voice Command Detection for Trigger-Free Speech Interface
NASA Astrophysics Data System (ADS)
Obuchi, Yasunari; Sumiyoshi, Takashi
In this paper we introduce a new framework of audio processing, which is essential to achieve a trigger-free speech interface for home appliances. If the speech interface works continually in real environments, it must extract occasional voice commands and reject everything else. It is extremely important to reduce the number of false alarms because the number of irrelevant inputs is much larger than the number of voice commands even for heavy users of appliances. The framework, called Intentional Voice Command Detection, is based on voice activity detection, but enhanced by various speech/audio processing techniques such as emotion recognition. The effectiveness of the proposed framework is evaluated using a newly-collected large-scale corpus. The advantages of combining various features were tested and confirmed, and the simple LDA-based classifier demonstrated acceptable performance. The effectiveness of various methods of user adaptation is also discussed.
Vollmer, Anne-Maria; Skonetzki-Cheng, Stefan; Prokosch, Hans-Ulrich
2013-01-01
Typically general wards and intensive care units (ICU) have very different labor organizations, structures and IT-systems in Germany. There is a need for coordination, because of the different working arrangements. Our team investigated the interface between ICU and general ward and especially the respective information transfer in the University hospital in Erlangen (Bavaria, Germany). The research team used a combination of interviews, observations and the analysis of transfer records and forms as part of a methodical triangulation. We identified 41 topics, which are discussed or presented in writing during the handover. In a second step, we investigate the requirements of data transmission in expert interviews. A data transfer concept from the perspective of the nurses and physicians was developed and we formulated recommendations for improvements of process and communication for this interface. Finally the data transfer concept was evaluated by the respondents.
Feasibility study for future implantable neural-silicon interface devices.
Al-Armaghany, Allann; Yu, Bo; Mak, Terrence; Tong, Kin-Fai; Sun, Yihe
2011-01-01
The emerging neural-silicon interface devices bridge nerve systems with artificial systems and play a key role in neuro-prostheses and neuro-rehabilitation applications. Integrating neural signal collection, processing and transmission on a single device will make clinical applications more practical and feasible. This paper focuses on the wireless antenna part and real-time neural signal analysis part of implantable brain-machine interface (BMI) devices. We propose to use millimeter-wave for wireless connections between different areas of a brain. Various antenna, including microstrip patch, monopole antenna and substrate integrated waveguide antenna are considered for the intra-cortical proximity communication. A Hebbian eigenfilter based method is proposed for multi-channel neuronal spike sorting. Folding and parallel design techniques are employed to explore various structures and make a trade-off between area and power consumption. Field programmable logic arrays (FPGAs) are used to evaluate various structures.
Wireless Control of Smartphones with Tongue Motion Using Tongue Drive Assistive Technology
Kim, Jeonghee; Huo, Xueliang
2010-01-01
Tongue Drive System (TDS) is a noninvasive, wireless and wearable assistive technology that helps people with severe disabilities control their environments using their tongue motion. TDS translates specific tongue gestures to commands by detecting a small permanent magnetic tracer on the users’ tongue. We have linked the TDS to a smartphone (iPhone/iPod Touch) with a customized wireless module, added to the iPhone. We also migrated and ran the TDS sensor signal processing algorithm and graphical user interface on the iPhone in real time. The TDS-iPhone interface was evaluated by four able-bodied subjects for dialing 10-digit phone numbers using the standard telephone keypad and three methods of prompting the numbers: visual, auditory, and cognitive. Preliminary results showed that the interface worked quite reliably at a rate of 15.4 digits per minute, on average, with negligible errors. PMID:21096049
Matched Interface and Boundary Method for Elasticity Interface Problems
Wang, Bao; Xia, Kelin; Wei, Guo-Wei
2015-01-01
Elasticity theory is an important component of continuum mechanics and has had widely spread applications in science and engineering. Material interfaces are ubiquity in nature and man-made devices, and often give rise to discontinuous coefficients in the governing elasticity equations. In this work, the matched interface and boundary (MIB) method is developed to address elasticity interface problems. Linear elasticity theory for both isotropic homogeneous and inhomogeneous media is employed. In our approach, Lamé’s parameters can have jumps across the interface and are allowed to be position dependent in modeling isotropic inhomogeneous material. Both strong discontinuity, i.e., discontinuous solution, and weak discontinuity, namely, discontinuous derivatives of the solution, are considered in the present study. In the proposed method, fictitious values are utilized so that the standard central finite different schemes can be employed regardless of the interface. Interface jump conditions are enforced on the interface, which in turn, accurately determines fictitious values. We design new MIB schemes to account for complex interface geometries. In particular, the cross derivatives in the elasticity equations are difficult to handle for complex interface geometries. We propose secondary fictitious values and construct geometry based interpolation schemes to overcome this difficulty. Numerous analytical examples are used to validate the accuracy, convergence and robustness of the present MIB method for elasticity interface problems with both small and large curvatures, strong and weak discontinuities, and constant and variable coefficients. Numerical tests indicate second order accuracy in both L∞ and L2 norms. PMID:25914439
Expedient Spall Repair Methods and Equipment for Airfield Pavements Preprint
2009-08-01
placement (3). RESEACH OBJECTIVES AND SCOPE The objective of this research was to develop one or more methods that will allow field personnel to...cores were used to perform in-situ tensile pull-off tests to evaluate the bond between the repair material and the substrate. Also, a series of 4...inch diameters cores were cut, and direct shear tests were performed on the repair material/substrate interface. Finally, all spalls were trafficked for
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kikinzon, Evgeny; Kuznetsov, Yuri; Lipnikov, Konstatin
In this study, we describe a new algorithm for solving multi-material diffusion problem when material interfaces are not aligned with the mesh. In this case interface reconstruction methods are used to construct approximate representation of interfaces between materials. They produce so-called multi-material cells, in which materials are represented by material polygons that contain only one material. The reconstructed interface is not continuous between cells. Finally, we suggest the new method for solving multi-material diffusion problems on such meshes and compare its performance with known homogenization methods.
Kikinzon, Evgeny; Kuznetsov, Yuri; Lipnikov, Konstatin; ...
2017-07-08
In this study, we describe a new algorithm for solving multi-material diffusion problem when material interfaces are not aligned with the mesh. In this case interface reconstruction methods are used to construct approximate representation of interfaces between materials. They produce so-called multi-material cells, in which materials are represented by material polygons that contain only one material. The reconstructed interface is not continuous between cells. Finally, we suggest the new method for solving multi-material diffusion problems on such meshes and compare its performance with known homogenization methods.
USDA-ARS?s Scientific Manuscript database
Molecular investigations of the ruminant response to ectoparasites at the parasite-host interface are critically dependent upon the quality of RNA. The complexity of ruminant skin decreases the capacity to obtain high quality RNA from biopsy samples, which directly affects the reliability of data pr...
Lima, Adriano Fonseca; Soares, Giulliana Panfiglio; Vasconcellos, Pedro Henrique; Ambrosano, Gláucia Maria; Marchi, Giselle Maria; Lovadino, José Roberto; Aguiar, Flávio Henrique
2011-06-01
To evaluate interface degradation leading to marginal microleakeage in Class II restorations that had received an application of surface sealant at the tooth/restoration interface or not. Eighty bovine incisors were used, and the teeth were split obliquely, 10 mm from the amelodentinal proximal junction, and finished with water abrasive papers to obtain a smooth, flat incisal surface. Cavities were made to simulate Class II preparations (8 mm high, 4 mm wide and 1.5 mm deep), and the restorations were performed with a composite resin. Teeth were then randomly allocated into 8 groups according to the surface sealant (none, Fortify, Single Bond 2, or Scothbond MP Plus) and aging process (none or thermocycling and storage for 6 months). Microleakage was then evaluated using a dye penetration method immediately after the restoration or after aging. The samples were triturated and assessed by spectrophotometer. Microleakage was statistically similar in all groups when assessed immediately after the restorative procedure. After aging, teeth sealed with Fortify presented better results than the other groups. Aging causes interface degradation and increased microleakage. Surface sealant can reduce these effects and decrease microleakage in Class II restorations.
Haptic Stylus and Empirical Studies on Braille, Button, and Texture Display
Kyung, Ki-Uk; Lee, Jun-Young; Park, Junseok
2008-01-01
This paper presents a haptic stylus interface with a built-in compact tactile display module and an impact module as well as empirical studies on Braille, button, and texture display. We describe preliminary evaluations verifying the tactile display's performance indicating that it can satisfactorily represent Braille numbers for both the normal and the blind. In order to prove haptic feedback capability of the stylus, an experiment providing impact feedback mimicking the click of a button has been conducted. Since the developed device is small enough to be attached to a force feedback device, its applicability to combined force and tactile feedback display in a pen-held haptic device is also investigated. The handle of pen-held haptic interface was replaced by the pen-like interface to add tactile feedback capability to the device. Since the system provides combination of force, tactile and impact feedback, three haptic representation methods for texture display have been compared on surface with 3 texture groups which differ in direction, groove width, and shape. In addition, we evaluate its capacity to support touch screen operations by providing tactile sensations when a user rubs against an image displayed on a monitor. PMID:18317520
Haptic stylus and empirical studies on braille, button, and texture display.
Kyung, Ki-Uk; Lee, Jun-Young; Park, Junseok
2008-01-01
This paper presents a haptic stylus interface with a built-in compact tactile display module and an impact module as well as empirical studies on Braille, button, and texture display. We describe preliminary evaluations verifying the tactile display's performance indicating that it can satisfactorily represent Braille numbers for both the normal and the blind. In order to prove haptic feedback capability of the stylus, an experiment providing impact feedback mimicking the click of a button has been conducted. Since the developed device is small enough to be attached to a force feedback device, its applicability to combined force and tactile feedback display in a pen-held haptic device is also investigated. The handle of pen-held haptic interface was replaced by the pen-like interface to add tactile feedback capability to the device. Since the system provides combination of force, tactile and impact feedback, three haptic representation methods for texture display have been compared on surface with 3 texture groups which differ in direction, groove width, and shape. In addition, we evaluate its capacity to support touch screen operations by providing tactile sensations when a user rubs against an image displayed on a monitor.
Mouthpiece ventilation in Duchenne muscular dystrophy: a rescue strategy for noncompliant patients
Fiorentino, Giuseppe; Annunziata, Anna; Cauteruccio, Rosa; Frega, Gianfranco Scotto di; Esquinas, Antonio
2016-01-01
ABSTRACT Objective: To evaluate mouthpiece ventilation (MPV) in patients with Duchenne muscular dystrophy (DMD) who are noncompliant with noninvasive ventilation (NIV). Methods: We evaluated four young patients with DMD who had previously refused to undergo NIV. Each patient was reassessed and encouraged to try MPV. Results: The four patients tolerated MPV well and were compliant with NIV at home. MPV proved to be preferable and more comfortable than NIV with any other type of interface. Two of the patients required overnight NIV and eventually agreed to use a nasal mask during the night. Conclusions: The advantages of MPV over other types of NIV include fewer speech problems, better appearance, and less impact on the patient, eliminating the risk of skin breakdown, gastric distension, conjunctivitis, and claustrophobia. The use of a mouthpiece interface should be always considered in patients with DMD who need to start NIV, in order to promote a positive approach and a rapid acceptance of NIV. Using MPV during the daytime makes patients feel safe and more likely to use NIV at night. In addition, MPV increases treatment compliance for those who refuse to use other types of interfaces. PMID:28117478
Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface.
do Nascimento, Cássio; Pedrazzi, Vinícius; Miani, Paola Kirsten; Moreira, Larissa Daher; de Albuquerque, Rubens Ferreira
2009-12-01
Bacterial penetration along the implant-abutment interface as a consequence of abutment screw loosening has been reported in a number of recent studies. The aim of this in vitro study was to investigate the influence of repeated tightening of the abutment screw on leakage of Streptococcus mutans along the interface between implants and pre-machined abutments. Twenty pre-machined abutments with a plastic sleeve were used. The abutment screws were tightened to 32 N cm in group 1 (n=10 - control) and to 32 N cm, loosened and re-tightened with the same torque twice in group 2 (n=10). The assemblies were completely immersed in 5 ml of Tryptic Soy Broth medium inoculated with S. mutans and incubated for 14 days. After this period, contamination of the implant internal threaded chamber was evaluated using the DNA Checkerboard method. Microorganisms were found on the internal surfaces of both groups evaluated. However, bacterial counts in group 2 were significantly higher than that in the control group (P<0.05). These results suggest that bacterial leakage between implants and abutments occurs even under unloaded conditions and at a higher intensity when the abutment screw is tightened and loosened repeatedly.
The effect of human-mattress interface's temperature on perceived thermal comfort.
Califano, R; Naddeo, A; Vink, P
2017-01-01
In recent years, methods that allow for an objective evaluation of perceived comfort, in terms of postural, physiological, cognitive and environmental comfort, have received a great deal of attention from researchers. This paper focuses on one of the factors that influences physiological comfort perception: the temperature difference between users and the objects with which they interact. The first aim is to create a measuring system that does not affect the perceived comfort during the temperatures' acquisition. The main aim is to evaluate how the temperature at the human-mattress interface can affect the level of perceived comfort. A foam mattress has been used for testing in order to take into account the entire back part of the human body. The temperature at the interface was registered by fourteen 100 Ohm Platinum RTDs (Resistance Temperature Detectors) placed on the mattress under the trunk, the shoulders, the buttocks, the legs, the thighs, the arms and the forearms of the test subject. 29 subjects participated in a comfort test in a humidity controlled environment. The test protocol involved: dress-code, anthropometric-based positioning on mattress, environment temperature measuring and an acclimatization time before the test. At the end of each test, each of the test subject's thermal sensations and the level of comfort perception were evaluated using the ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) scale. The data analyses concerned, in the first instance, correlations between the temperature at the interface and comfort levels of the different parts of the body. Then the same analyses were performed independently of the body parts being considered. The results demonstrated that there was no strong correlation among the studied variables and that the total increase of temperature at interface is associated with a reduction in comfort. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zheng, Hua; Rosal, Milagros C; Li, Wenjun; Borg, Amy; Yang, Wenyun; Ayers, David C; Franklin, Patricia D
2018-04-30
Data-driven surgical decisions will ensure proper use and timing of surgical care. We developed a Web-based patient-centered treatment decision and assessment tool to guide treatment decisions among patients with advanced knee osteoarthritis who are considering total knee replacement surgery. The aim of this study was to examine user experience and acceptance of the Web-based treatment decision support tool among older adults. User-centered formative and summative evaluations were conducted for the tool. A sample of 28 patients who were considering total knee replacement participated in the study. Participants' responses to the user interface design, the clarity of information, as well as usefulness, satisfaction, and acceptance of the tool were collected through qualitative (ie, individual patient interviews) and quantitative (ie, standardized Computer System Usability Questionnaire) methods. Participants were older adults with a mean age of 63 (SD 11) years. Three-quarters of them had no technical questions using the tool. User interface design recommendations included larger fonts, bigger buttons, less colors, simpler navigation without extra "next page" click, less mouse movement, and clearer illustrations with simple graphs. Color-coded bar charts and outcome-specific graphs with positive action were easiest for them to understand the outcomes data. Questionnaire data revealed high satisfaction with the tool usefulness and interface quality, and also showed ease of use of the tool, regardless of age or educational status. We evaluated the usability of a patient-centered decision support tool designed for advanced knee arthritis patients to facilitate their knee osteoarthritis treatment decision making. The lessons learned can inform other decision support tools to improve interface and content design for older patients' use. ©Hua Zheng, Milagros C Rosal, Wenjun Li, Amy Borg, Wenyun Yang, David C Ayers, Patricia D Franklin. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 30.04.2018.
Hirai, Daiki; Iwao, Yasunori; Kimura, Shin-Ichiro; Noguchi, Shuji; Itai, Shigeru
2017-04-30
Metastable crystals and the amorphous state of poorly water-soluble drugs in solid dispersions (SDs), are subject to a solid-liquid interface reaction upon exposure to a solvent. The dissolution behavior during the solid-liquid interface reaction often shows that the concentration of drugs is supersaturated, with a high initial drug concentration compared with the solubility of stable crystals but finally approaching the latter solubility with time. However, a method for measuring the precipitation rate of stable crystals and/or the potential solubility of metastable crystals or amorphous drugs has not been established. In this study, a novel mathematical model that can represent the dissolution behavior of the solid-liquid interface reaction for metastable crystals or amorphous drug was developed and its validity was evaluated. The theory for this model was based on the Noyes-Whitney equation and assumes that the precipitation of stable crystals at the solid-liquid interface occurs through a first-order reaction. Moreover, two models were developed, one assuming that the surface area of the drug remains constant because of the presence of excess drug in the bulk and the other that the surface area changes in time-dependency because of agglomeration of the drug. SDs of Ibuprofen (IB)/polyvinylpyrrolidone (PVP) were prepared and their dissolution behaviors under non-sink conditions were fitted by the models to evaluate improvements in solubility. The model assuming time-dependent surface area showed good agreement with experimental values. Furthermore, by applying the model to the dissolution profile, parameters such as the precipitation rate and the potential solubility of the amorphous drug were successfully calculated. In addition, it was shown that the improvement in solubility with supersaturation was able to be evaluated quantitatively using this model. Therefore, this mathematical model would be a useful tool to quantitatively determine the supersaturation concentration of a metastable drug from solid dispersions. Copyright © 2017 Elsevier B.V. All rights reserved.
Thesaurus-Enhanced Search Interfaces.
ERIC Educational Resources Information Center
Shiri, Ali Asghar; Revie, Crawford; Chowdhury, Gobinda
2002-01-01
Discussion of user interfaces to information retrieval systems focuses on interfaces that incorporate thesauri as part of their searching and browsing facilities. Discusses research literature related to information searching behavior, information retrieval interface evaluation, search term selection, and query expansion; and compares thesaurus…
Chang, Po-Chun; Seol, Yang-Jo; Goldstein, Steven A.; Giannobile, William V.
2014-01-01
Purpose It is currently a challenge to determine the biomechanical properties of the hard tissue–dental implant interface. Recent advances in intraoral imaging and tomographic methods, such as microcomputed tomography (micro-CT), provide three-dimensional details, offering significant potential to evaluate the bone-implant interface, but yield limited information regarding osseointegration because of physical scattering effects emanating from metallic implant surfaces. In the present study, it was hypothesized that functional apparent moduli (FAM), generated from functional incorporation of the peri-implant structure, would eliminate the radiographic artifact–affected layer and serve as a feasible means to evaluate the biomechanical dynamics of tissue-implant integration in vivo. Materials and Methods Cylindric titanium mini-implants were placed in osteotomies and osteotomies with defects in rodent maxillae. The layers affected by radiographic artifacts were identified, and the pattern of tissue-implant integration was evaluated from histology and micro-CT images over a 21-day observation period. Analyses of structural information, FAM, and the relationship between FAM and interfacial stiffness (IS) were done before and after eliminating artifacts. Results Physical artifacts were present within a zone of about 100 to 150 μm around the implant in both experimental defect situations (osteotomy alone and osteotomy + defect). All correlations were evaluated before and after eliminating the artifact-affected layers, most notably during the maturation period of osseointegration. A strong correlation existed between functional bone apparent modulus and IS within 300 μm at the osteotomy defects (r > 0.9) and functional composite tissue apparent modulus in the osteotomy defects (r > 0.75). Conclusion Micro-CT imaging and FAM were of value in measuring the temporal process of tissue-implant integration in vivo. This approach will be useful to complement imaging technologies for longitudinal monitoring of osseointegration. PMID:23377049
Marco-Ruiz, Luis; Bønes, Erlend; de la Asunción, Estela; Gabarron, Elia; Aviles-Solis, Juan Carlos; Lee, Eunji; Traver, Vicente; Sato, Keiichi; Bellika, Johan G
2017-10-01
Symptom checkers are software tools that allow users to submit a set of symptoms and receive advice related to them in the form of a diagnosis list, health information or triage. The heterogeneity of their potential users and the number of different components in their user interfaces can make testing with end-users unaffordable. We designed and executed a two-phase method to test the respiratory diseases module of the symptom checker Erdusyk. Phase I consisted of an online test with a large sample of users (n=53). In Phase I, users evaluated the system remotely and completed a questionnaire based on the Technology Acceptance Model. Principal Component Analysis was used to correlate each section of the interface with the questionnaire responses, thus identifying which areas of the user interface presented significant contributions to the technology acceptance. In the second phase, the think-aloud procedure was executed with a small number of samples (n=15), focusing on the areas with significant contributions to analyze the reasons for such contributions. Our method was used effectively to optimize the testing of symptom checker user interfaces. The method allowed kept the cost of testing at reasonable levels by restricting the use of the think-aloud procedure while still assuring a high amount of coverage. The main barriers detected in Erdusyk were related to problems understanding time repetition patterns, the selection of levels in scales to record intensities, navigation, the quantification of some symptom attributes, and the characteristics of the symptoms. Copyright © 2017 Elsevier Inc. All rights reserved.
Human perceptual deficits as factors in computer interface test and evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowser, S.E.
1992-06-01
Issues related to testing and evaluating human computer interfaces are usually based on the machine rather than on the human portion of the computer interface. Perceptual characteristics of the expected user are rarely investigated, and interface designers ignore known population perceptual limitations. For these reasons, environmental impacts on the equipment will more likely be defined than will user perceptual characteristics. The investigation of user population characteristics is most often directed toward intellectual abilities and anthropometry. This problem is compounded by the fact that some deficits capabilities tend to be found in higher-than-overall population distribution in some user groups. The testmore » and evaluation community can address the issue from two primary aspects. First, assessing user characteristics should be extended to include tests of perceptual capability. Secondly, interface designs should use multimode information coding.« less
2014-08-01
daily) hydrology UI user interface of a model USGS U.S. Geological Survey USLE Universal Soil Loss Equation used to compute soil erosion rate for...SCS curve number runoff method, inches or m It daily infiltration rate for day t, m/day K soil erodibility factor in the USLE and MUSLE L length...and soil erosion (using the Universal Soil Loss Equation, or USLE ) as a reference even when time-varying hydrology is selected for use. The UI also
Analysis of the flow in a 1-MJ electric-arc shock tunnel
NASA Technical Reports Server (NTRS)
Reller, J. O., Jr.; Reddy, N. M.
1972-01-01
In the electric-arc-heated shock tunnel, the facility performance over a range of shock Mach numbers from 7 to 19 was evaluated. The efficiency of the arc-heated driver is deduced using an improved form of the shock tube equation. A theoretical and experimental analysis is made of the tailored-interface condition. The free stream properties in the test section, with nitrogen as the test gas, are evaluated using a method based on stagnation point, heat transfer measurements.
Joyce, Brendan; Lee, Danny; Rubio, Alex; Ogurtsov, Aleksey; Alves, Gelio; Yu, Yi-Kuo
2018-03-15
RAId is a software package that has been actively developed for the past 10 years for computationally and visually analyzing MS/MS data. Founded on rigorous statistical methods, RAId's core program computes accurate E-values for peptides and proteins identified during database searches. Making this robust tool readily accessible for the proteomics community by developing a graphical user interface (GUI) is our main goal here. We have constructed a graphical user interface to facilitate the use of RAId on users' local machines. Written in Java, RAId_GUI not only makes easy executions of RAId but also provides tools for data/spectra visualization, MS-product analysis, molecular isotopic distribution analysis, and graphing the retrieval versus the proportion of false discoveries. The results viewer displays and allows the users to download the analyses results. Both the knowledge-integrated organismal databases and the code package (containing source code, the graphical user interface, and a user manual) are available for download at https://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads/raid.html .
Ion dehydration controls adsorption at the micellar interface: hydrotropic ions.
Lima, Filipe S; Andrade, Marcos F C; Mortara, Laura; Gustavo Dias, Luís; Cuccovia, Iolanda M; Chaimovich, Hernan
2017-11-22
The properties of ionic micelles depend on the nature of the counterion, and these effects become more evident as the ion adsorption at the interface increases. Prediction of the relative extent of ion adsorption is required for rational design of ionic micellar aggregates. Unlike the well understood adsorption of monatomic ions, the adsorption of polyatomic ions is not easily predicted. We combined experimental and computational methods to evaluate the affinity of hydrotropic ions, i.e., ions with polar and apolar regions, to the surface of positively charged micelles. We analyzed cationic micelles of dodecyltrimethylammonium and six hydrotropic counterions: methanesulfonate, trifluoromethanesulfonate, benzenesulfonate, acetate, trifluoroacetate and benzoate. Our results demonstrated that the apolar region of hydrotropic ions had the largest influence on micellar properties. The dehydration of the apolar region of hydrotropic ions upon their adsorption at the micellar interface determined the ion adsorption extension, differently to what was expected based on Collins' law of matching affinities. These results may lead to more general models to describe the adsorption of ions, including polyatomic ions, at the micellar interface.
An automated decision-tree approach to predicting protein interaction hot spots.
Darnell, Steven J; Page, David; Mitchell, Julie C
2007-09-01
Protein-protein interactions can be altered by mutating one or more "hot spots," the subset of residues that account for most of the interface's binding free energy. The identification of hot spots requires a significant experimental effort, highlighting the practical value of hot spot predictions. We present two knowledge-based models that improve the ability to predict hot spots: K-FADE uses shape specificity features calculated by the Fast Atomic Density Evaluation (FADE) program, and K-CON uses biochemical contact features. The combined K-FADE/CON (KFC) model displays better overall predictive accuracy than computational alanine scanning (Robetta-Ala). In addition, because these methods predict different subsets of known hot spots, a large and significant increase in accuracy is achieved by combining KFC and Robetta-Ala. The KFC analysis is applied to the calmodulin (CaM)/smooth muscle myosin light chain kinase (smMLCK) interface, and to the bone morphogenetic protein-2 (BMP-2)/BMP receptor-type I (BMPR-IA) interface. The results indicate a strong correlation between KFC hot spot predictions and mutations that significantly reduce the binding affinity of the interface. 2007 Wiley-Liss, Inc.
Space-time interface-tracking with topology change (ST-TC)
NASA Astrophysics Data System (ADS)
Takizawa, Kenji; Tezduyar, Tayfun E.; Buscher, Austin; Asada, Shohei
2014-10-01
To address the computational challenges associated with contact between moving interfaces, such as those in cardiovascular fluid-structure interaction (FSI), parachute FSI, and flapping-wing aerodynamics, we introduce a space-time (ST) interface-tracking method that can deal with topology change (TC). In cardiovascular FSI, our primary target is heart valves. The method is a new version of the deforming-spatial-domain/stabilized space-time (DSD/SST) method, and we call it ST-TC. It includes a master-slave system that maintains the connectivity of the "parent" mesh when there is contact between the moving interfaces. It is an efficient, practical alternative to using unstructured ST meshes, but without giving up on the accurate representation of the interface or consistent representation of the interface motion. We explain the method with conceptual examples and present 2D test computations with models representative of the classes of problems we are targeting.
2014-01-01
Background The fatigue that users suffer when using steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs) can cause a number of serious problems such as signal quality degradation and system performance deterioration, users’ discomfort and even risk of photosensitive epileptic seizures, posing heavy restrictions on the applications of SSVEP-based BCIs. Towards alleviating the fatigue, a fundamental step is to measure and evaluate it but most existing works adopt self-reported questionnaire methods which are subjective, offline and memory dependent. This paper proposes an objective and real-time approach based on electroencephalography (EEG) spectral analysis to evaluate the fatigue in SSVEP-based BCIs. Methods How the EEG indices (amplitudes in δ, θ, α and β frequency bands), the selected ratio indices (θ/α and (θ + α)/β), and SSVEP properties (amplitude and signal-to-noise ratio (SNR)) changes with the increasing fatigue level are investigated through two elaborate SSVEP-based BCI experiments, one validates mainly the effectiveness and another considers more practical situations. Meanwhile, a self-reported fatigue questionnaire is used to provide a subjective reference. ANOVA is employed to test the significance of the difference between the alert state and the fatigue state for each index. Results Consistent results are obtained in two experiments: the significant increases in α and (θ + α)/β, as well as the decrease in θ/α are found associated with the increasing fatigue level, indicating that EEG spectral analysis can provide robust objective evaluation of the fatigue in SSVEP-based BCIs. Moreover, the results show that the amplitude and SNR of the elicited SSVEP are significantly affected by users’ fatigue. Conclusions The experiment results demonstrate the feasibility and effectiveness of the proposed method as an objective and real-time evaluation of the fatigue in SSVEP-based BCIs. This method would be helpful in understanding the fatigue problem and optimizing the system design to alleviate the fatigue in SSVEP-based BCIs. PMID:24621009
Kim, Seongmin; Kim, Hwansoo; Janes, David B; Ju, Sanghyun
2013-08-02
Due to the large surface-to-volume ratio of nanowires, the quality of nanowire-insulator interfaces as well as the nanowire surface characteristics significantly influence the electrical characteristics of nanowire transistors (NWTs). To improve the electrical characteristics by doping or post-processing, it is important to evaluate the interface characteristics and stability of NWTs. In this study, we have synthesized ZnSnO (ZTO) nanowires using the chemical vapor deposition method, characterized the composition of ZTO nanowires using x-ray photoelectron spectroscopy, and fabricated ZTO NWTs. We have characterized the current-voltage characteristics and low-frequency noise of ZTO NWTs in order to investigate the effects of interface states on subthreshold slope (SS) and the noise before and after N2 plasma treatments. The as-fabricated device exhibited a SS of 0.29 V/dec and Hooge parameter of ~1.20 × 10(-2). Upon N2 plasma treatment with N2 gas flow rate of 40 sccm (20 sccm), the SS improved to 0.12 V/dec (0.21 V/dec) and the Hooge parameter decreased to ~4.99 × 10(-3) (8.14 × 10(-3)). The interface trap densities inferred from both SS and low-frequency noise decrease upon plasma treatment, with the highest flow rate yielding the smallest trap density. These results demonstrate that the N2 plasma treatment decreases the interface trap states and defects on ZTO nanowires, thereby enabling the fabrication of high-quality nanowire interfaces.
An overlapped grid method for multigrid, finite volume/difference flow solvers: MaGGiE
NASA Technical Reports Server (NTRS)
Baysal, Oktay; Lessard, Victor R.
1990-01-01
The objective is to develop a domain decomposition method via overlapping/embedding the component grids, which is to be used by upwind, multi-grid, finite volume solution algorithms. A computer code, given the name MaGGiE (Multi-Geometry Grid Embedder) is developed to meet this objective. MaGGiE takes independently generated component grids as input, and automatically constructs the composite mesh and interpolation data, which can be used by the finite volume solution methods with or without multigrid convergence acceleration. Six demonstrative examples showing various aspects of the overlap technique are presented and discussed. These cases are used for developing the procedure for overlapping grids of different topologies, and to evaluate the grid connection and interpolation data for finite volume calculations on a composite mesh. Time fluxes are transferred between mesh interfaces using a trilinear interpolation procedure. Conservation losses are minimal at the interfaces using this method. The multi-grid solution algorithm, using the coaser grid connections, improves the convergence time history as compared to the solution on composite mesh without multi-gridding.
The Measurement of the Surface Energy of Solids by Sessile Drop Accelerometry
NASA Astrophysics Data System (ADS)
Calvimontes, Alfredo
2018-05-01
A new physical method, the sessile drop accelerometry (SDACC) for the study and measurement of the interfacial energies of solid-liquid-gas systems, is tested and discussed in this study. The laboratory instrument and technique—a combination of a drop shape analyzer with high-speed camera and a laboratory drop tower- and the evaluation algorithms, were designed to calculate the interfacial energies as a function of the geometrical changes of a sessile droplet shape due to the effect of "switching off" gravity during the experiment. The method bases on Thermodynamics of Interfaces and differs from the conventional approach of the two hundred-years-old Young's equation in that it assumes a thermodynamic equilibrium between interfaces, rather than a balance of tensions on a point of the solid-liquid-gas contour line. A comparison of the mathematical model that supports the method with the widely accepted Young`s equation is discussed in detail in this study. The method opens new possibilities to develop surface characterization procedures by submitting the solid-liquid-system to artificial generated and uniform force fields.
New KF-PP-SVM classification method for EEG in brain-computer interfaces.
Yang, Banghua; Han, Zhijun; Zan, Peng; Wang, Qian
2014-01-01
Classification methods are a crucial direction in the current study of brain-computer interfaces (BCIs). To improve the classification accuracy for electroencephalogram (EEG) signals, a novel KF-PP-SVM (kernel fisher, posterior probability, and support vector machine) classification method is developed. Its detailed process entails the use of common spatial patterns to obtain features, based on which the within-class scatter is calculated. Then the scatter is added into the kernel function of a radial basis function to construct a new kernel function. This new kernel is integrated into the SVM to obtain a new classification model. Finally, the output of SVM is calculated based on posterior probability and the final recognition result is obtained. To evaluate the effectiveness of the proposed KF-PP-SVM method, EEG data collected from laboratory are processed with four different classification schemes (KF-PP-SVM, KF-SVM, PP-SVM, and SVM). The results showed that the overall average improvements arising from the use of the KF-PP-SVM scheme as opposed to KF-SVM, PP-SVM and SVM schemes are 2.49%, 5.83 % and 6.49 % respectively.
Cao, Yong; Chu, Yuchuan; He, Xiaoming; ...
2013-01-01
This paper proposes a domain decomposition method for the coupled stationary Navier-Stokes and Darcy equations with the Beavers-Joseph-Saffman interface condition in order to improve the efficiency of the finite element method. The physical interface conditions are directly utilized to construct the boundary conditions on the interface and then decouple the Navier-Stokes and Darcy equations. Newton iteration will be used to deal with the nonlinear systems. Numerical results are presented to illustrate the features of the proposed method.
NASA Astrophysics Data System (ADS)
Luo, Xiangcheng
Material contacts, including thermal, electrical, seating (fluid sealing and electromagnetic sealing) and mechanical (pressure) contacts, together with their interface materials, were, evaluated, and in some cases, improved beyond the state of the art. The evaluation involved the use of thermal, electrical and mechanical methods. For thermal contacts, this work evaluated and improved the heat transfer efficiency between two contacting components by developing various thermal interface pastes. Sodium silicate based thermal pastes (with boron nitride particles as the thermally conductive filler) as well as polyethylene glycol (PEG) based thermal pastes were developed and evaluated. The optimum volume fractions of BN in sodium silicate based pastes and PEG based pastes were 16% and 18% respectively. The contribution of Li+ ions to the thermal contact conductance in the PEG-based paste was confirmed. For electrical contacts, the relationship between the mechanical reliability and electrical reliability of solder/copper and silver-epoxy/copper joints was addressed. Mechanical pull-out testing was conducted on solder/copper and silver-epoxy/copper joints, while the contact electrical resistivity was measured. Cleansing of the copper surface was more effective for the reliability of silver-epoxy/copper joint than that of solder/copper joint. For sealing contacts, this work evaluated flexible graphite as an electromagnetic shielding gasket material. Flexible graphite was found to be at least comparable to conductive filled silicone (the state of the art) in terms of the shielding effectiveness. The conformability of flexible graphite with its mating metal surface under repeated compression was characterized by monitoring the contact electrical resistance, as the conformability is important to both electromagnetic scaling and fluid waling using flexible graphite. For mechanical contacts, this work focused on the correlation of the interface structure (such as elastic/plastic deformation, oxidation, strain hardening, passive layer damage, fracture, etc.) with the electrical contact resistance, which was measured in real time for contacts under dynamic compression, thus allowing both reversible and irreversible changes to be observed. The materials studied included metals (carbon steel, stainless steel, aluminum and copper), carbon fiber reinforced polymer-matrix composite (nylon-6), ceramic (mortar) and graphite, due to their relevance to fastening, concrete structures, electric brushes and electrical pressure contacts.
A new method for promoting adhesion between precious metal alloys and dental adhesives.
Ohno, H; Araki, Y; Endo, K
1992-06-01
A new, simple method of modifying the adherend metal surface by a liquid Ga-Sn alloy (Adlloy) was applied to dental precious and base-metal alloys for adhesion with 4-META adhesive resin. Adhesions of 4-META resin to three other surface states--as-polished, oxidized at high temperature, and electroplated tin--were also performed for comparison with the adhesion on Adlloy-modified surfaces. Bond strength measurements were made, and the durability against water at the adhering interface was evaluated. The Adlloy-modified gold alloys (Type IV and 14 K) and silver-based alloys (Ag-Pd and Ag-Cu) showed not only high bond strengths but also excellent water durability at the adhesion interface. Surface modification by Adlloy, however, did not affect adhesion to Ag-In-Zn and base-metal (SUS, Co-Cr, and Ni-Cr) alloys. Adhesion to the tin-electroplated specimens was comparable with that to the Adlloy-modified specimens.
Jackson, Bret; Coffey, Dane; Thorson, Lauren; Schroeder, David; Ellingson, Arin M; Nuckley, David J; Keefe, Daniel F
2012-10-01
In this position paper we discuss successes and limitations of current evaluation strategies for scientific visualizations and argue for embracing a mixed methods strategy of evaluation. The most novel contribution of the approach that we advocate is a new emphasis on employing design processes as practiced in related fields (e.g., graphic design, illustration, architecture) as a formalized mode of evaluation for data visualizations. To motivate this position we describe a series of recent evaluations of scientific visualization interfaces and computer graphics strategies conducted within our research group. Complementing these more traditional evaluations our visualization research group also regularly employs sketching, critique, and other design methods that have been formalized over years of practice in design fields. Our experience has convinced us that these activities are invaluable, often providing much more detailed evaluative feedback about our visualization systems than that obtained via more traditional user studies and the like. We believe that if design-based evaluation methodologies (e.g., ideation, sketching, critique) can be taught and embraced within the visualization community then these may become one of the most effective future strategies for both formative and summative evaluations.
Jackson, Bret; Coffey, Dane; Thorson, Lauren; Schroeder, David; Ellingson, Arin M.; Nuckley, David J.
2017-01-01
In this position paper we discuss successes and limitations of current evaluation strategies for scientific visualizations and argue for embracing a mixed methods strategy of evaluation. The most novel contribution of the approach that we advocate is a new emphasis on employing design processes as practiced in related fields (e.g., graphic design, illustration, architecture) as a formalized mode of evaluation for data visualizations. To motivate this position we describe a series of recent evaluations of scientific visualization interfaces and computer graphics strategies conducted within our research group. Complementing these more traditional evaluations our visualization research group also regularly employs sketching, critique, and other design methods that have been formalized over years of practice in design fields. Our experience has convinced us that these activities are invaluable, often providing much more detailed evaluative feedback about our visualization systems than that obtained via more traditional user studies and the like. We believe that if design-based evaluation methodologies (e.g., ideation, sketching, critique) can be taught and embraced within the visualization community then these may become one of the most effective future strategies for both formative and summative evaluations. PMID:28944349
Recent work on material interface reconstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mosso, S.J.; Swartz, B.K.
1997-12-31
For the last 15 years, many Eulerian codes have relied on a series of piecewise linear interface reconstruction algorithms developed by David Youngs. In a typical Youngs` method, the material interfaces were reconstructed based upon nearly cell values of volume fractions of each material. The interfaces were locally represented by linear segments in two dimensions and by pieces of planes in three dimensions. The first step in such reconstruction was to locally approximate an interface normal. In Youngs` 3D method, a local gradient of a cell-volume-fraction function was estimated and taken to be the local interface normal. A linear interfacemore » was moved perpendicular to the now known normal until the mass behind it matched the material volume fraction for the cell in question. But for distorted or nonorthogonal meshes, the gradient normal estimate didn`t accurately match that of linear material interfaces. Moreover, curved material interfaces were also poorly represented. The authors will present some recent work in the computation of more accurate interface normals, without necessarily increasing stencil size. Their estimate of the normal is made using an iterative process that, given mass fractions for nearby cells of known but arbitrary variable density, converges in 3 or 4 passes in practice (and quadratically--like Newton`s method--in principle). The method reproduces a linear interface in both orthogonal and nonorthogonal meshes. The local linear approximation is generally 2nd-order accurate, with a 1st-order accurate normal for curved interfaces in both two and three dimensional polyhedral meshes. Recent work demonstrating the interface reconstruction for curved surfaces will /be discussed.« less
Soft brain-machine interfaces for assistive robotics: A novel control approach.
Schiatti, Lucia; Tessadori, Jacopo; Barresi, Giacinto; Mattos, Leonardo S; Ajoudani, Arash
2017-07-01
Robotic systems offer the possibility of improving the life quality of people with severe motor disabilities, enhancing the individual's degree of independence and interaction with the external environment. In this direction, the operator's residual functions must be exploited for the control of the robot movements and the underlying dynamic interaction through intuitive and effective human-robot interfaces. Towards this end, this work aims at exploring the potential of a novel Soft Brain-Machine Interface (BMI), suitable for dynamic execution of remote manipulation tasks for a wide range of patients. The interface is composed of an eye-tracking system, for an intuitive and reliable control of a robotic arm system's trajectories, and a Brain-Computer Interface (BCI) unit, for the control of the robot Cartesian stiffness, which determines the interaction forces between the robot and environment. The latter control is achieved by estimating in real-time a unidimensional index from user's electroencephalographic (EEG) signals, which provides the probability of a neutral or active state. This estimated state is then translated into a stiffness value for the robotic arm, allowing a reliable modulation of the robot's impedance. A preliminary evaluation of this hybrid interface concept provided evidence on the effective execution of tasks with dynamic uncertainties, demonstrating the great potential of this control method in BMI applications for self-service and clinical care.
Emotion scents: a method of representing user emotions on GUI widgets
NASA Astrophysics Data System (ADS)
Cernea, Daniel; Weber, Christopher; Ebert, Achim; Kerren, Andreas
2013-01-01
The world of desktop interfaces has been dominated for years by the concept of windows and standardized user interface (UI) components. Still, while supporting the interaction and information exchange between the users and the computer system, graphical user interface (GUI) widgets are rather one-sided, neglecting to capture the subjective facets of the user experience. In this paper, we propose a set of design guidelines for visualizing user emotions on standard GUI widgets (e.g., buttons, check boxes, etc.) in order to enrich the interface with a new dimension of subjective information by adding support for emotion awareness as well as post-task analysis and decision making. We highlight the use of an EEG headset for recording the various emotional states of the user while he/she is interacting with the widgets of the interface. We propose a visualization approach, called emotion scents, that allows users to view emotional reactions corresponding to di erent GUI widgets without in uencing the layout or changing the positioning of these widgets. Our approach does not focus on highlighting the emotional experience during the interaction with an entire system, but on representing the emotional perceptions and reactions generated by the interaction with a particular UI component. Our research is motivated by enabling emotional self-awareness and subjectivity analysis through the proposed emotionenhanced UI components for desktop interfaces. These assumptions are further supported by an evaluation of emotion scents.
Nanoscale deformation measurements for reliability assessment of material interfaces
NASA Astrophysics Data System (ADS)
Keller, Jürgen; Gollhardt, Astrid; Vogel, Dietmar; Michel, Bernd
2006-03-01
With the development and application of micro/nano electronic mechanical systems (MEMS, NEMS) for a variety of market segments new reliability issues will arise. The understanding of material interfaces is the key for a successful design for reliability of MEMS/NEMS and sensor systems. Furthermore in the field of BIOMEMS newly developed advanced materials and well known engineering materials are combined despite of fully developed reliability concepts for such devices and components. In addition the increasing interface-to volume ratio in highly integrated systems and nanoparticle filled materials are challenges for experimental reliability evaluation. New strategies for reliability assessment on the submicron scale are essential to fulfil the needs of future devices. In this paper a nanoscale resolution experimental method for the measurement of thermo-mechanical deformation at material interfaces is introduced. The determination of displacement fields is based on scanning probe microscopy (SPM) data. In-situ SPM scans of the analyzed object (i.e. material interface) are carried out at different thermo-mechanical load states. The obtained images are compared by grayscale cross correlation algorithms. This allows the tracking of local image patterns of the analyzed surface structure. The measurement results are full-field displacement fields with nanometer resolution. With the obtained data the mixed mode type of loading at material interfaces can be analyzed with highest resolution for future needs in micro system and nanotechnology.
Turley, James P; Johnson, Todd R; Smith, Danielle Paige; Zhang, Jaijie; Brixey, Juliana J
2006-04-01
Use of medical devices often directly contributes to medical errors. Because it is difficult or impossible to change the design of existing devices, the best opportunity for improving medical device safety is during the purchasing process. However, most hospital personnel are not familiar with the usability evaluation methods designed to identify aspects of a user interface that do not support intuitive and safe use. A review of medical device operating manuals is proposed as a more practical method of usability evaluation. Operating manuals for five volumetric infusion pumps from three manufacturers were selected for this study (January-April 2003). Each manual's safety message content was evaluated to determine whether the message indicated a device design characteristic that violated known usability principles (heuristics) or indicated a violation of an affordance of the device. "Minimize memory load," with 65 violations, was the heuristic violated most frequently across pumps. Variations between pumps, including the frequency and severity of violations for each, were noted. Results suggest that manual review can provide a proxy for heuristic evaluation of the actual medical device. This method, intended to be a component of prepurchasing evaluation, can complement more formal usability evaluation methods and be used to select a subset of devices for more extensive and formal testing.
Corneal electrolysis for recurrence of corneal stromal dystrophy after keratoplasty
Mashima, Y; Kawai, M; Yamada, M
2002-01-01
Aims: To evaluate corneal electrolysis as a treatment for recurrent diffuse corneal opacities at the host-graft interface of the stroma or at the subepithelial region in two types of granular corneal dystrophy (GCD). Methods: Recurrence developed at the host-graft interface of the stroma after lamellar keratoplasty in a patient with Avellino corneal dystrophy (ACD). At surgery, the deep aspect of the graft in this patient was partially separated from host tissue to expose the deposits, with one third of the host-graft junction left intact. The graft was everted, and electrolysis was applied directly to remove the deposits attached to both surfaces of the host and the graft. Then the graft was returned to its place and sutured. In two patients with homozygous ACD and one patient with the superficial variant of GCD, diffuse subepithelial opacities developed following penetrating keratoplasty. Electrolysis was applied directly to the corneal surface. Results: Deposits at the host-graft interface of the stroma and in the subepithelial region disappeared following treatment, and vision recovered in all patients. Conclusions: This method is a simple, easy, and inexpensive way to remove deposits that recur after lamellar or penetrating keratoplasty. PMID:11864880
Nishi, Naoya; Hashimoto, Atsunori; Minami, Eiji; Sakka, Tetsuo
2015-02-21
The structure of ionic liquids (ILs) at the electrochemical IL|Hg interface has been studied using the pendant drop method. From the electrocapillarity (potential dependence of interfacial tension) differential capacitance (Cd) at zero frequency (in other words, static differential capacitance or differential capacitance in equilibrium) has been evaluated. The potential dependence of zero-frequency Cd at the IL|Hg interface exhibits one or two local maxima near the potential of zero charge (Epzc), depending on the cation of the ILs. For 1-ethyl-3-methylimidazolium tetrafluoroborate, an IL with the cation having a short alkyl chain, the Cdvs. potential curve has one local maximum whereas another IL, 1-octyl-3-methylimidazolium tetrafluoroborate, with the cation having a long alkyl chain, shows two maxima. These behaviors of zero-frequency Cd agree with prediction by recent theoretical and simulation studies for the electrical double layer in ILs. At negative and positive potentials far from Epzc, the zero-frequency Cd increases for both the ILs studied. The increase in zero-frequency Cd is attributable to the densification of ionic layers in the electrical double layer.
libvdwxc: a library for exchange-correlation functionals in the vdW-DF family
NASA Astrophysics Data System (ADS)
Hjorth Larsen, Ask; Kuisma, Mikael; Löfgren, Joakim; Pouillon, Yann; Erhart, Paul; Hyldgaard, Per
2017-09-01
We present libvdwxc, a general library for evaluating the energy and potential for the family of vdW-DF exchange-correlation functionals. libvdwxc is written in C and provides an efficient implementation of the vdW-DF method and can be interfaced with various general-purpose DFT codes. Currently, the Gpaw and Octopus codes implement interfaces to libvdwxc. The present implementation emphasizes scalability and parallel performance, and thereby enables ab initio calculations of nanometer-scale complexes. The numerical accuracy is benchmarked on the S22 test set whereas parallel performance is benchmarked on ligand-protected gold nanoparticles ({{Au}}144{({{SC}}11{{NH}}25)}60) up to 9696 atoms.
NASA Technical Reports Server (NTRS)
Brown, Christopher A.
1993-01-01
The approach of the project is to base the design of multi-function, reflective topographies on the theory that topographically dependent phenomena react with surfaces and interfaces at certain scales. The first phase of the project emphasizes the development of methods for understanding the sizes of topographic features which influence reflectivity. Subsequent phases, if necessary, will address the scales of interaction for adhesion and manufacturing processes. A simulation of the interaction of electromagnetic radiation, or light, with a reflective surface is performed using specialized software. Reflectivity of the surface as a function of scale is evaluated and the results from the simulation are compared with reflectivity measurements made on multi-function, reflective surfaces.
A smoothed two- and three-dimensional interface reconstruction method
Mosso, Stewart; Garasi, Christopher; Drake, Richard
2008-04-22
The Patterned Interface Reconstruction algorithm reduces the discontinuity between material interfaces in neighboring computational elements. This smoothing improves the accuracy of the reconstruction for smooth bodies. The method can be used in two- and three-dimensional Cartesian and unstructured meshes. Planar interfaces will be returned for planar volume fraction distributions. Finally, the algorithm is second-order accurate for smooth volume fraction distributions.
Integrating Human Factors into Crew Exploration Vehicle Design
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Baggerman, Susan; Campbell, paul
2007-01-01
With NASA's new Vision for Exploration to send humans beyond Earth orbit, it is critical to consider the human as a system that demands early and continuous user involvement, and an iterative prototype/test/redesign process. Addressing human-system interface issues early on can be very cost effective even cost reducing when performed early in the design and development cycle. To achieve this goal within Crew Exploration Vehicle (CEV) Project Office, human engineering (HE) team is formed. Key tasks are to apply HE requirements and guidelines to hardware/software, and provide HE design, analysis and evaluation of crew interfaces. Initial activities included many practice-orientated evaluations using low-fidelity CEV mock-ups. What follows is a description of such evaluations that focused on a HE requirement regarding Net Habitable Volume (NHV). NHV is defined as the total remaining pressurized volume available to on-orbit crew after accounting for the loss of volume due to deployed hardware and structural inefficiencies which decrease functional volume. The goal of the NHV evaluations was to develop requirements providing sufficient CEV NHV for crewmembers to live and perform tasks in support of mission goals. Efforts included development of a standard NHV calculation method using computer models and physical mockups, and crew/ stakeholder evaluations. Nine stakeholders and ten crewmembers participated in the unsuited evaluations. Six crewmembers also participated in a suited evaluation. The mock-up was outfitted with volumetric representation of sub-systems such as seats, and stowage bags. Thirteen scenarios were developed to represent mission/crew tasks and considered to be primary volume drivers (e.g., suit donning) for the CEV. Unsuited evaluations included a structured walkthrough of these tasks. Suited evaluations included timed donning of the existing launch and entry suit to simulate a contingency scenario followed by doffing/ stowing of the suits. All mockup evaluations were videotaped. Structured questionnaires were used to document user interface issues and volume impacts of layout configuration. Computer model and physical measures of the NHV agreed within 1 percent. This included measurement of the gross habitable volume, subtraction of intrusive volumes, and other non-habitable spaces. Calculation method developed was validated as a standard means of measuring NHV, and was recommended as a verification method for the NHV requirements. Evaluations confirmed that there was adequate volume for unsuited scenarios and suit donning/ doffing activity. Seats, suit design stowage and waste hygiene system noted to be critical volume drivers. The low-fidelity mock-up evaluations along with human modeling analysis generated discussions that will lead to high-level systems requirements and human-centered design decisions. This approach allowed HE requirements and operational concepts to evolve in parallel with engineering system concepts and design requirements. As the CEV design matures, these evaluations will continue and help with design decisions, and assessment, verification and validation of HE requirements.
Yuan, Michael Juntao; Finley, George Mike; Mills, Christy; Johnson, Ron Kim
2013-01-01
Background Clinical decision support systems (CDSS) are important tools to improve health care outcomes and reduce preventable medical adverse events. However, the effectiveness and success of CDSS depend on their implementation context and usability in complex health care settings. As a result, usability design and validation, especially in real world clinical settings, are crucial aspects of successful CDSS implementations. Objective Our objective was to develop a novel CDSS to help frontline nurses better manage critical symptom changes in hospitalized patients, hence reducing preventable failure to rescue cases. A robust user interface and implementation strategy that fit into existing workflows was key for the success of the CDSS. Methods Guided by a formal usability evaluation framework, UFuRT (user, function, representation, and task analysis), we developed a high-level specification of the product that captures key usability requirements and is flexible to implement. We interviewed users of the proposed CDSS to identify requirements, listed functions, and operations the system must perform. We then designed visual and workflow representations of the product to perform the operations. The user interface and workflow design were evaluated via heuristic and end user performance evaluation. The heuristic evaluation was done after the first prototype, and its results were incorporated into the product before the end user evaluation was conducted. First, we recruited 4 evaluators with strong domain expertise to study the initial prototype. Heuristic violations were coded and rated for severity. Second, after development of the system, we assembled a panel of nurses, consisting of 3 licensed vocational nurses and 7 registered nurses, to evaluate the user interface and workflow via simulated use cases. We recorded whether each session was successfully completed and its completion time. Each nurse was asked to use the National Aeronautics and Space Administration (NASA) Task Load Index to self-evaluate the amount of cognitive and physical burden associated with using the device. Results A total of 83 heuristic violations were identified in the studies. The distribution of the heuristic violations and their average severity are reported. The nurse evaluators successfully completed all 30 sessions of the performance evaluations. All nurses were able to use the device after a single training session. On average, the nurses took 111 seconds (SD 30 seconds) to complete the simulated task. The NASA Task Load Index results indicated that the work overhead on the nurses was low. In fact, most of the burden measures were consistent with zero. The only potentially significant burden was temporal demand, which was consistent with the primary use case of the tool. Conclusions The evaluation has shown that our design was functional and met the requirements demanded by the nurses’ tight schedules and heavy workloads. The user interface embedded in the tool provided compelling utility to the nurse with minimal distraction. PMID:23612350
A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators
NASA Technical Reports Server (NTRS)
Norcross, Jason R.; Chappell, Steve; Cowley, Matthew S.; Harvill, Lauren; Gernhardt, Michael L.
2010-01-01
The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were off-loaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.
A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators
NASA Technical Reports Server (NTRS)
Norcross, Jason; Gernhardt, Michael; Chappell, Steve; Cowley, Matt
2011-01-01
The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were offloaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.
Ge, Liang; Sotiropoulos, Fotis
2007-08-01
A novel numerical method is developed that integrates boundary-conforming grids with a sharp interface, immersed boundary methodology. The method is intended for simulating internal flows containing complex, moving immersed boundaries such as those encountered in several cardiovascular applications. The background domain (e.g the empty aorta) is discretized efficiently with a curvilinear boundary-fitted mesh while the complex moving immersed boundary (say a prosthetic heart valve) is treated with the sharp-interface, hybrid Cartesian/immersed-boundary approach of Gilmanov and Sotiropoulos [1]. To facilitate the implementation of this novel modeling paradigm in complex flow simulations, an accurate and efficient numerical method is developed for solving the unsteady, incompressible Navier-Stokes equations in generalized curvilinear coordinates. The method employs a novel, fully-curvilinear staggered grid discretization approach, which does not require either the explicit evaluation of the Christoffel symbols or the discretization of all three momentum equations at cell interfaces as done in previous formulations. The equations are integrated in time using an efficient, second-order accurate fractional step methodology coupled with a Jacobian-free, Newton-Krylov solver for the momentum equations and a GMRES solver enhanced with multigrid as preconditioner for the Poisson equation. Several numerical experiments are carried out on fine computational meshes to demonstrate the accuracy and efficiency of the proposed method for standard benchmark problems as well as for unsteady, pulsatile flow through a curved, pipe bend. To demonstrate the ability of the method to simulate flows with complex, moving immersed boundaries we apply it to calculate pulsatile, physiological flow through a mechanical, bileaflet heart valve mounted in a model straight aorta with an anatomical-like triple sinus.
Ge, Liang; Sotiropoulos, Fotis
2008-01-01
A novel numerical method is developed that integrates boundary-conforming grids with a sharp interface, immersed boundary methodology. The method is intended for simulating internal flows containing complex, moving immersed boundaries such as those encountered in several cardiovascular applications. The background domain (e.g the empty aorta) is discretized efficiently with a curvilinear boundary-fitted mesh while the complex moving immersed boundary (say a prosthetic heart valve) is treated with the sharp-interface, hybrid Cartesian/immersed-boundary approach of Gilmanov and Sotiropoulos [1]. To facilitate the implementation of this novel modeling paradigm in complex flow simulations, an accurate and efficient numerical method is developed for solving the unsteady, incompressible Navier-Stokes equations in generalized curvilinear coordinates. The method employs a novel, fully-curvilinear staggered grid discretization approach, which does not require either the explicit evaluation of the Christoffel symbols or the discretization of all three momentum equations at cell interfaces as done in previous formulations. The equations are integrated in time using an efficient, second-order accurate fractional step methodology coupled with a Jacobian-free, Newton-Krylov solver for the momentum equations and a GMRES solver enhanced with multigrid as preconditioner for the Poisson equation. Several numerical experiments are carried out on fine computational meshes to demonstrate the accuracy and efficiency of the proposed method for standard benchmark problems as well as for unsteady, pulsatile flow through a curved, pipe bend. To demonstrate the ability of the method to simulate flows with complex, moving immersed boundaries we apply it to calculate pulsatile, physiological flow through a mechanical, bileaflet heart valve mounted in a model straight aorta with an anatomical-like triple sinus. PMID:19194533
Tang, Muh-Chyun; Liu, Ying-Hsang; Wu, Wan-Ching
2013-09-01
Previous research has shown that information seekers in biomedical domain need more support in formulating their queries. A user study was conducted to evaluate the effectiveness of a metadata based query suggestion interface for PubMed bibliographic search. The study also investigated the impact of search task familiarity on search behaviors and the effectiveness of the interface. A real user, user search request and real system approach was used for the study. Unlike tradition IR evaluation, where assigned tasks were used, the participants were asked to search requests of their own. Forty-four researchers in Health Sciences participated in the evaluation - each conducted two research requests of their own, alternately with the proposed interface and the PubMed baseline. Several performance criteria were measured to assess the potential benefits of the experimental interface, including users' assessment of their original and eventual queries, the perceived usefulness of the interfaces, satisfaction with the search results, and the average relevance score of the saved records. The results show that, when searching for an unfamiliar topic, users were more likely to change their queries, indicating the effect of familiarity on search behaviors. The results also show that the interface scored higher on several of the performance criteria, such as the "goodness" of the queries, perceived usefulness, and user satisfaction. Furthermore, in line with our hypothesis, the proposed interface was relatively more effective when less familiar search requests were attempted. Results indicate that there is a selective compatibility between search familiarity and search interface. One implication of the research for system evaluation is the importance of taking into consideration task familiarity when assessing the effectiveness of interactive IR systems. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Hai-Xia; Wang, Xiao-Xu; Beijing Computing Center, Beijing 100094
Ag/ZnO interfaces have been investigated for both of Zn-termination and O-termination by the first principle based on density functional theory. Our calculations demonstrate that the Ag atoms go inward from the Ag/ZnO interface, and the Zn and O atoms are all move outward bulk in the Zn-termination interface, and the changes are just opposite for O-termination. These behaviors are in agreement with the other studies in literatures. Furthermore, an expansion situation is observed in the first two Zn-O bilayer and first three Ag monolayers for both of Zn-termination and O-termination interfaces by comparing with the pure ZnO(0001) and Ag(111) surfaces.more » Moreover, the valence-band both of O-2p and Zn-3d states of Ag/ZnO interface gradual close to Femi level as the Zn, O atoms locate at the deeper layer for Zn-termination, but it is the other way round for O-termination. Calculated absorption spectrum indicates that the absorption intensity of Zn-termination interface is stronger than that of O-termination in the lower energy range (visible light region). These properties of ZnO surfaces are also evaluated for comparison with interfaces. - Graphical abstract: The structures of Ag/ZnO interface: Zn-termination (left) and O-termination (right). In this Ag/ZnO interface system, the ZnO (0001) surface is rotated 30°(R30), and Ag (111) surface is built (2×2) supercell, then a (2×√3) R30 Ag/ZnO interface is constructed using the supercell method (i.e. periodically repeated slabs). The lattice mismatch of (2×√3) R30 Ag/ZnO (2.6% mismatch) is smaller than that of (1×1) Ag/ZnO (11% mismatch).« less
1991-09-01
iv III. THE ANALYTIC HIERARCHY PROCESS ..... ........ 15 A. INTRODUCTION ...... ................. 15 B. THE AHP PROCESS ...... ................ 16 C...INTRODUCTION ...... ................. 26 B. IMPLEMENTATION OF CERTS USING AHP ........ .. 27 1. Consistency ...... ................ 29 2. User Interface...the proposed technique into a Decision Support System. Expert Choice implements the Analytic Hierarchy Process ( AHP ), an approach to multi- criteria
Seedfall and seed viability within artificial canopy gaps in a western Washington douglas-fir forest
Warren D. Devine; Timothy B. Harrington
2015-01-01
Seedfall of coast Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco var. menziesii) has been studied at the forest edge-clearcut interface and in small canopy gaps, but it has not been evaluated in gap sizes that would be typical of a group-selection method of regeneration. In a mature Douglas-fir forest in the Puget Sound...
A reductionist approach to the analysis of learning in brain-computer interfaces.
Danziger, Zachary
2014-04-01
The complexity and scale of brain-computer interface (BCI) studies limit our ability to investigate how humans learn to use BCI systems. It also limits our capacity to develop adaptive algorithms needed to assist users with their control. Adaptive algorithm development is forced offline and typically uses static data sets. But this is a poor substitute for the online, dynamic environment where algorithms are ultimately deployed and interact with an adapting user. This work evaluates a paradigm that simulates the control problem faced by human subjects when controlling a BCI, but which avoids the many complications associated with full-scale BCI studies. Biological learners can be studied in a reductionist way as they solve BCI-like control problems, and machine learning algorithms can be developed and tested in closed loop with the subjects before being translated to full BCIs. The method is to map 19 joint angles of the hand (representing neural signals) to the position of a 2D cursor which must be piloted to displayed targets (a typical BCI task). An investigation is presented on how closely the joint angle method emulates BCI systems; a novel learning algorithm is evaluated, and a performance difference between genders is discussed.
Ripoche, Hugues; Laine, Elodie; Ceres, Nicoletta; Carbone, Alessandra
2017-01-04
The database JET2 Viewer, openly accessible at http://www.jet2viewer.upmc.fr/, reports putative protein binding sites for all three-dimensional (3D) structures available in the Protein Data Bank (PDB). This knowledge base was generated by applying the computational method JET 2 at large-scale on more than 20 000 chains. JET 2 strategy yields very precise predictions of interacting surfaces and unravels their evolutionary process and complexity. JET2 Viewer provides an online intelligent display, including interactive 3D visualization of the binding sites mapped onto PDB structures and suitable files recording JET 2 analyses. Predictions were evaluated on more than 15 000 experimentally characterized protein interfaces. This is, to our knowledge, the largest evaluation of a protein binding site prediction method. The overall performance of JET 2 on all interfaces are: Sen = 52.52, PPV = 51.24, Spe = 80.05, Acc = 75.89. The data can be used to foster new strategies for protein-protein interactions modulation and interaction surface redesign. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.
Initial constructs for patient-centered outcome measures to evaluate brain-computer interfaces
Andresen, Elena M.; Fried-Oken, Melanie; Peters, Betts; Patrick, Donald L.
2016-01-01
Purpose The authors describe preliminary work toward the creation of patient-centered outcome (PCO) measures to evaluate brain-computer interface (BCI) as an assistive technology for individuals with severe speech and physical impairments (SSPI). Method In Phase 1, 591 items from 15 existing measures were mapped to the International Classification of Functioning, Disability and Health (ICF). In Phase 2, qualitative interviews were conducted with eight people with SSPI and seven caregivers. Resulting text data were coded in an iterative analysis. Results Most items (79%) mapped to the ICF environmental domain; over half (53%) mapped to more than one domain. The ICF framework was well suited for mapping items related to body functions and structures, but less so for items in other areas, including personal factors. Two constructs emerged from qualitative data: Quality of Life (QOL) and Assistive Technology. Component domains and themes were identified for each. Conclusions Preliminary constructs, domains, and themes were generated for future PCO measures relevant to BCI. Existing instruments are sufficient for initial items but do not adequately match the values of people with SSPI and their caregivers. Field methods for interviewing people with SSPI were successful, and support the inclusion of these individuals in PCO research. PMID:25806719
High-resolution method for evolving complex interface networks
NASA Astrophysics Data System (ADS)
Pan, Shucheng; Hu, Xiangyu Y.; Adams, Nikolaus A.
2018-04-01
In this paper we describe a high-resolution transport formulation of the regional level-set approach for an improved prediction of the evolution of complex interface networks. The novelty of this method is twofold: (i) construction of local level sets and reconstruction of a global level set, (ii) local transport of the interface network by employing high-order spatial discretization schemes for improved representation of complex topologies. Various numerical test cases of multi-region flow problems, including triple-point advection, single vortex flow, mean curvature flow, normal driven flow, dry foam dynamics and shock-bubble interaction show that the method is accurate and suitable for a wide range of complex interface-network evolutions. Its overall computational cost is comparable to the Semi-Lagrangian regional level-set method while the prediction accuracy is significantly improved. The approach thus offers a viable alternative to previous interface-network level-set method.
Systems and methods for compensating for electrical converter nonlinearities
Perisic, Milun; Ransom, Ray M.; Kajouke, Lateef A.
2013-06-18
Systems and methods are provided for delivering energy from an input interface to an output interface. An electrical system includes an input interface, an output interface, an energy conversion module coupled between the input interface and the output interface, and a control module. The control module determines a duty cycle control value for operating the energy conversion module to produce a desired voltage at the output interface. The control module determines an input power error at the input interface and adjusts the duty cycle control value in a manner that is influenced by the input power error, resulting in a compensated duty cycle control value. The control module operates switching elements of the energy conversion module to deliver energy to the output interface with a duty cycle that is influenced by the compensated duty cycle control value.
A Python Interface for the Dakota Iterative Systems Analysis Toolkit
NASA Astrophysics Data System (ADS)
Piper, M.; Hutton, E.; Syvitski, J. P.
2016-12-01
Uncertainty quantification is required to improve the accuracy, reliability, and accountability of Earth science models. Dakota is a software toolkit, developed at Sandia National Laboratories, that provides an interface between models and a library of analysis methods, including support for sensitivity analysis, uncertainty quantification, optimization, and calibration techniques. Dakota is a powerful tool, but its learning curve is steep: the user not only must understand the structure and syntax of the Dakota input file, but also must develop intermediate code, called an analysis driver, that allows Dakota to run a model. The CSDMS Dakota interface (CDI) is a Python package that wraps and extends Dakota's user interface. It simplifies the process of configuring and running a Dakota experiment. A user can program to the CDI, allowing a Dakota experiment to be scripted. The CDI creates Dakota input files and provides a generic analysis driver. Any model written in Python that exposes a Basic Model Interface (BMI), as well as any model componentized in the CSDMS modeling framework, automatically works with the CDI. The CDI has a plugin architecture, so models written in other languages, or those that don't expose a BMI, can be accessed by the CDI by programmatically extending a template; an example is provided in the CDI distribution. Currently, six Dakota analysis methods have been implemented for examples from the much larger Dakota library. To demonstrate the CDI, we performed an uncertainty quantification experiment with the HydroTrend hydrological water balance and transport model. In the experiment, we evaluated the response of long-term suspended sediment load at the river mouth (Qs) to uncertainty in two input parameters, annual mean temperature (T) and precipitation (P), over a series of 100-year runs, using the polynomial chaos method. Through Dakota, we calculated moments, local and global (Sobol') sensitivity indices, and probability density and cumulative distribution functions for the response.
Alonso-García, Teodoro; Rodríguez-Presa, María José; Gervasi, Claudio; Moya, Sergio; Azzaroni, Omar
2013-07-16
Devising strategies to assess the glass transition temperature (Tg) of polyelectrolyte assemblies at solid-electrolyte interfaces is very important to understand and rationalize the temperature-dependent behavior of polyelectrolyte films in a wide range of settings. Despite the evolving perception of the importance of measuring Tg under aqueous conditions in thin film configurations, its straightforward measurement poses a challenging situation that still remains elusive in polymer and materials science. Here, we describe a new method based on electrochemical impedance spectroscopy (EIS) to estimate the glass transition temperature of planar polyelectrolyte brushes at solid-liquid interfaces. To measure Tg, the charge transfer resistance (Rct) of a redox probe diffusing through the polyelectrolyte brush was measured, and the temperature corresponding to the discontinuous change in Rct was identified as Tg. Furthermore, we demonstrate that impedance measurements not only facilitate the estimation of Tg but also enable a reliable evaluation of the transport properties of the polymeric interface, i.e., determination of diffusion coefficients, close to the thermal transition. We consider that this approach bridges the gap between electrochemistry and the traditional tools used in polymer science and offers new opportunities to characterize the thermal behavior of complex polymeric interfaces and macromolecular assemblies.
Tan, Fabing; Yang, Chongshi; Huang, Yuanding
2017-01-01
Introduction Osseointegration is required for prosthetic implant, but the various bone-implant interfaces of orthodontic miniscrews would be a great interest for the orthodontist. There is no clear consensus regarding the minimum amount of bone-implant osseointegration required for a stable miniscrew. The objective of this study was to investigate the influence of different bone-implant interfaces on the miniscrew and its surrounding tissue. Methods Using finite element analysis, an advanced approach representing the bone-implant interface is adopted herein, and different degrees of bone-implant osseointegration were implemented in the FE models. A total of 26 different FE analyses were performed. The stress/strain patterns were calculated and compared, and the displacement of miniscrews was also evaluated. Results The stress/strain distributions are changing with the various bone-implant interfaces. In the scenario of 0% osseointegration, a rather homogeneous distribution was predicted. After 15% osseointegration, the stress/strains were gradually concentrated on the cortical bone region. The miniscrew experienced the largest displacement under the no osseointegra condition. The maximum displacement decreases sharply from 0% to 3% and tends to become stable. Conclusion From a biomechanical perspective, it can be suggested that orthodontic loading could be applied on miniscrews after about 15% osseointegration without any loss of stability. PMID:29065641
Okamoto, Eiji; Kato, Yoshikuni; Kikuchi, Sakiko; Mitamura, Yoshinori
2014-01-01
The electrical property between an electrode and skin or tissue is one of the important issues for communication performance of the transcutaneous communication system (TCS) using a human body as a conductive medium.In this study, we used a simple method to measure interface resistance between the electrode and skin on the surface of the body. The electrode-electrode impedance was measured by a commercially available LCR meter with changes in the distance between two electrodes on an arm of a healthy male subject, and we obtained the tissue resistivity and electrode-skin interface resistance using the cross-sectional area of the arm.We also measured transmission gain of the TCS on the surface of the body, and we investigated the relationship between electrode-skin interface resistance and transmission gain. We examined four kinds of electrodes: a stainless steel electrode, a titanium electrode, an Ag-AgCl electrode and an Ag-AgCl paste electrode. The stainless steel electrode, which had lower electrode-skin resistance, had higher transmission gain.The results indicate that an electrode that has lower electrode-skin resistance will contribute to improvement of the performance of the TCS and that electrode-skin interface resistance is one of valuable evaluation parameters for selecting an optimum electrode for the TCS.
Lei, Yanqiang; Lu, Xiaoqing
2017-04-15
A one-step hydrothermal method was adopted to synthesize the Ag 2 O/TiO 2 nanoheterojunction. Its photocatalytic activity was evaluated by degrading methylene blue (MB) aqueous solution under UV and visible light. The MB degradation results showed that the Ag 2 O/TiO 2 nanoheterojunction enhances the photocatalytic activity under UV irradiation rather than visible light. X-ray photoelectron spectroscopy (XPS) was performed to detect the electronic structure at the interface of Ag 2 O and TiO 2 . The XPS results confirmed that the electronic band structure of the nanoheterojunction was determined by the interface states between the Ag 2 O and TiO 2 interface. Thus, the photocatalytic enhancement mechanism can be ascribed to the creation of an additional potential barrier in the conduction band between Ag 2 O and TiO 2 , which facilitates the transport of holes from TiO 2 to Ag 2 O but inhibits the flow of electrons in the reverse direction unless sufficient potential energy is provided to overcome the additional barrier. Our results have provided a new insight on the role of interface states between the p-n nanojunction in the photocatalytic activity. Copyright © 2017 Elsevier Inc. All rights reserved.
Graphic Interfaces and Online Information.
ERIC Educational Resources Information Center
Percival, J. Mark
1990-01-01
Discusses the growing importance of the use of Graphic User Interfaces (GUIs) with microcomputers and online services. Highlights include the development of graphics interfacing with microcomputers; CD-ROM databases; an evaluation of HyperCard as a potential interface to electronic mail and online commercial databases; and future possibilities.…
NASA Astrophysics Data System (ADS)
Wang, Xiaoping; Cai, Peijun; Liu, Yuling; Wang, Liqiang; Liang, Yiyong
2017-08-01
Courses are an important way of cultivating talents in college education. Advanced training schemes and the course system are implemented through course teaching. Advanced teaching notions and methods also rely on course teaching. Therefore, the quality of course teaching is the fundamental guarantor for grooming talent. The teachers of the course "Microcontroller Principles and Interface Techniques" in the Optical Science and Engineering College of Zhejiang University insist on course teaching becoming student centered and ability-training-oriented. They pay attention to students'all-round development in terms of learning ability, practical ability, innovation ability, and exploring spirit. They actively carried out course reforms in four aspects, namely teaching, learning, evaluation, and experimentation. This paper mainly introduced these reforms. First, the teaching method was reformed by introducing case analysis and the notion of a flipped classroom to shift the course focus from the teacher to the students. Second, the learning method was reformed through the use of techniques such as peer learning and project design to promote students' sense of enquiry and learning initiative. Third, the evaluation method was reformed through the use of process assessment and diversity evaluation to encourage students to develop logical thinking and a down-to-earth manner. Fourth, the experimentation method was reformed by introducing hierarchical content, process management, and diversification of examination to change students'learning attitude from "dependence, passivity, and imitation" to "independence, active involvement, and creation."In general, the teaching method reform promoted reforms in learning, evaluation, and experimentation methods and further improved the style of study. These reforms improved teachers' teaching abilities and enabled course teaching to transform from being teacher centered to student centered. Years of exploration and practice results have shown that such reforms not only effectively inspire students to learn, explore, and practice actively, but also cultivate their creative spirit and courage to face challenges, providing a good platform for theirself-learning and personal growth. The course reforms discussed here have been highly recommended for their reference value.
Vermeulen, Joan; Neyens, Jacques CL; Spreeuwenberg, Marieke D; van Rossum, Erik; Sipers, Walther; Habets, Herbert; Hewson, David J; de Witte, Luc P
2013-01-01
Purpose To involve elderly people during the development of a mobile interface of a monitoring system that provides feedback to them regarding changes in physical functioning and to test the system in a pilot study. Methods and participants The iterative user-centered development process consisted of the following phases: (1) selection of user representatives; (2) analysis of users and their context; (3) identification of user requirements; (4) development of the interface; and (5) evaluation of the interface in the lab. Subsequently, the monitoring and feedback system was tested in a pilot study by five patients who were recruited via a geriatric outpatient clinic. Participants used a bathroom scale to monitor weight and balance, and a mobile phone to monitor physical activity on a daily basis for six weeks. Personalized feedback was provided via the interface of the mobile phone. Usability was evaluated on a scale from 1 to 7 using a modified version of the Post-Study System Usability Questionnaire (PSSUQ); higher scores indicated better usability. Interviews were conducted to gain insight into the experiences of the participants with the system. Results The developed interface uses colors, emoticons, and written and/or spoken text messages to provide daily feedback regarding (changes in) weight, balance, and physical activity. The participants rated the usability of the monitoring and feedback system with a mean score of 5.2 (standard deviation 0.90) on the modified PSSUQ. The interviews revealed that most participants liked using the system and appreciated that it signaled changes in their physical functioning. However, usability was negatively influenced by a few technical errors. Conclusion Involvement of elderly users during the development process resulted in an interface with good usability. However, the technical functioning of the monitoring system needs to be optimized before it can be used to support elderly people in their self-management. PMID:24039407
To twist, roll, stroke or poke? A study of input devices for menu navigation in the cockpit.
Stanton, Neville A; Harvey, Catherine; Plant, Katherine L; Bolton, Luke
2013-01-01
Modern interfaces within the aircraft cockpit integrate many flight management system (FMS) functions into a single system. The success of a user's interaction with an interface depends upon the optimisation between the input device, tasks and environment within which the system is used. In this study, four input devices were evaluated using a range of Human Factors methods, in order to assess aspects of usability including task interaction times, error rates, workload, subjective usability and physical discomfort. The performance of the four input devices was compared using a holistic approach and the findings showed that no single input device produced consistently high performance scores across all of the variables evaluated. The touch screen produced the highest number of 'best' scores; however, discomfort ratings for this device were high, suggesting that it is not an ideal solution as both physical and cognitive aspects of performance must be accounted for in design. This study evaluated four input devices for control of a screen-based flight management system. A holistic approach was used to evaluate both cognitive and physical performance. Performance varied across the dependent variables and between the devices; however, the touch screen produced the largest number of 'best' scores.
Transfer Learning to Accelerate Interface Structure Searches
NASA Astrophysics Data System (ADS)
Oda, Hiromi; Kiyohara, Shin; Tsuda, Koji; Mizoguchi, Teruyasu
2017-12-01
Interfaces have atomic structures that are significantly different from those in the bulk, and play crucial roles in material properties. The central structures at the interfaces that provide properties have been extensively investigated. However, determination of even one interface structure requires searching for the stable configuration among many thousands of candidates. Here, a powerful combination of machine learning techniques based on kriging and transfer learning (TL) is proposed as a method for unveiling the interface structures. Using the kriging+TL method, thirty-three grain boundaries were systematically determined from 1,650,660 candidates in only 462 calculations, representing an increase in efficiency over conventional all-candidate calculation methods, by a factor of approximately 3,600.
Militello, L G; Hutton, R J
1998-11-01
Cognitive task analysis (CTA) is a set of methods for identifying cognitive skills, or mental demands, needed to perform a task proficiently. The product of the task analysis can be used to inform the design of interfaces and training systems. However, CTA is resource intensive and has previously been of limited use to design practitioners. A streamlined method of CTA, Applied Cognitive Task Analysis (ACTA), is presented in this paper. ACTA consists of three interview methods that help the practitioner to extract information about the cognitive demands and skills required for a task. ACTA also allows the practitioner to represent this information in a format that will translate more directly into applied products, such as improved training scenarios or interface recommendations. This paper will describe the three methods, an evaluation study conducted to assess the usability and usefulness of the methods, and some directions for future research for making cognitive task analysis accessible to practitioners. ACTA techniques were found to be easy to use, flexible, and to provide clear output. The information and training materials developed based on ACTA interviews were found to be accurate and important for training purposes.
Stabilised finite-element methods for solving the level set equation with mass conservation
NASA Astrophysics Data System (ADS)
Kabirou Touré, Mamadou; Fahsi, Adil; Soulaïmani, Azzeddine
2016-01-01
Finite-element methods are studied for solving moving interface flow problems using the level set approach and a stabilised variational formulation proposed in Touré and Soulaïmani (2012; Touré and Soulaïmani To appear in 2016), coupled with a level set correction method. The level set correction is intended to enhance the mass conservation satisfaction property. The stabilised variational formulation (Touré and Soulaïmani 2012; Touré and Soulaïmani, To appear in 2016) constrains the level set function to remain close to the signed distance function, while the mass conservation is a correction step which enforces the mass balance. The eXtended finite-element method (XFEM) is used to take into account the discontinuities of the properties within an element. XFEM is applied to solve the Navier-Stokes equations for two-phase flows. The numerical methods are numerically evaluated on several test cases such as time-reversed vortex flow, a rigid-body rotation of Zalesak's disc, sloshing flow in a tank, a dam-break over a bed, and a rising bubble subjected to buoyancy. The numerical results show the importance of satisfying global mass conservation to accurately capture the interface position.
A Method for Automated Detection of Usability Problems from Client User Interface Events
Saadawi, Gilan M.; Legowski, Elizabeth; Medvedeva, Olga; Chavan, Girish; Crowley, Rebecca S.
2005-01-01
Think-aloud usability analysis provides extremely useful data but is very time-consuming and expensive to perform because of the extensive manual video analysis that is required. We describe a simple method for automated detection of usability problems from client user interface events for a developing medical intelligent tutoring system. The method incorporates (1) an agent-based method for communication that funnels all interface events and system responses to a centralized database, (2) a simple schema for representing interface events and higher order subgoals, and (3) an algorithm that reproduces the criteria used for manual coding of usability problems. A correction factor was empirically determining to account for the slower task performance of users when thinking aloud. We tested the validity of the method by simultaneously identifying usability problems using TAU and manually computing them from stored interface event data using the proposed algorithm. All usability problems that did not rely on verbal utterances were detectable with the proposed method. PMID:16779121
A Hybrid 2D/3D User Interface for Radiological Diagnosis.
Mandalika, Veera Bhadra Harish; Chernoglazov, Alexander I; Billinghurst, Mark; Bartneck, Christoph; Hurrell, Michael A; Ruiter, Niels de; Butler, Anthony P H; Butler, Philip H
2018-02-01
This paper presents a novel 2D/3D desktop virtual reality hybrid user interface for radiology that focuses on improving 3D manipulation required in some diagnostic tasks. An evaluation of our system revealed that our hybrid interface is more efficient for novice users and more accurate for both novice and experienced users when compared to traditional 2D only interfaces. This is a significant finding because it indicates, as the techniques mature, that hybrid interfaces can provide significant benefit to image evaluation. Our hybrid system combines a zSpace stereoscopic display with 2D displays, and mouse and keyboard input. It allows the use of 2D and 3D components interchangeably, or simultaneously. The system was evaluated against a 2D only interface with a user study that involved performing a scoliosis diagnosis task. There were two user groups: medical students and radiology residents. We found improvements in completion time for medical students, and in accuracy for both groups. In particular, the accuracy of medical students improved to match that of the residents.
LI, ZHILIN; JI, HAIFENG; CHEN, XIAOHONG
2016-01-01
A new augmented method is proposed for elliptic interface problems with a piecewise variable coefficient that has a finite jump across a smooth interface. The main motivation is not only to get a second order accurate solution but also a second order accurate gradient from each side of the interface. The key of the new method is to introduce the jump in the normal derivative of the solution as an augmented variable and re-write the interface problem as a new PDE that consists of a leading Laplacian operator plus lower order derivative terms near the interface. In this way, the leading second order derivatives jump relations are independent of the jump in the coefficient that appears only in the lower order terms after the scaling. An upwind type discretization is used for the finite difference discretization at the irregular grid points near or on the interface so that the resulting coefficient matrix is an M-matrix. A multi-grid solver is used to solve the linear system of equations and the GMRES iterative method is used to solve the augmented variable. Second order convergence for the solution and the gradient from each side of the interface has also been proved in this paper. Numerical examples for general elliptic interface problems have confirmed the theoretical analysis and efficiency of the new method. PMID:28983130
Toledano, Manuel; Osorio, Raquel; Osorio, Estrella; Cabello, Inmaculada; Toledano-Osorio, Manuel; Aguilera, Fátima S
2018-06-01
The aim of this study was to evaluate the induced changes in the chemical and mechanical performance at the glass-ionomer cement-dentin interface after mechanical load application. A conventional glass-ionomer cement (GIC) (Ketac Bond), and a resin-modified glass-ionomer cement (RMGIC) (Vitrebond Plus) were used. Bonded interfaces were stored in simulated body fluid, and then tested or submitted to the mechanical loading challenge. Different loading waveforms were applied: No cycling, 24 h cycled in sine or loaded in sustained hold waveforms. The cement-dentin interface was evaluated using a nano-dynamic mechanical analysis, estimating the complex modulus and tan δ. Atomic Force Microscopy (AFM) imaging, Raman analysis and dye assisted confocal microscopy evaluation (CLSM) were also performed. The complex modulus was lower and tan delta was higher at interfaces promoted with the GIC if compared to the RMGIC unloaded. The conventional GIC attained evident reduction of nanoleakage. Mechanical loading favored remineralization and promoted higher complex modulus and lower tan delta values at interfaces with RMGIC, where porosity, micropermeability and nanoleakage were more abundant. Mechanical stimuli diminished the resistance to deformation and increased the stored energy at the GIC-dentin interface. The conventional GIC induced less porosity and nanoleakage than RMGIC. The RMGIC increased nanoleakage at the porous interface, and dye sorption appeared within the cement. Both cements created amorphous and crystalline apatites at the interface depending on the type of mechanical loading. Remineralization, lower stress concentration and resistance to deformation after mechanical loading improved the sealing of the GIC-dentin interface. In vitro oral function will favor high levels of accumulated energy and permits micropermeability at the RMGIC-dentin interface which will become remineralized. Copyright © 2018 Elsevier Ltd. All rights reserved.
Kushniruk, Andre W; Kan, Min-Yem; McKeown, Kathleen; Klavans, Judith; Jordan, Desmond; LaFlamme, Mark; Patel, Vimia L
2002-01-01
This paper describes the comparative evaluation of an experimental automated text summarization system, Centrifuser and three conventional search engines - Google, Yahoo and About.com. Centrifuser provides information to patients and families relevant to their questions about specific health conditions. It then produces a multidocument summary of articles retrieved by a standard search engine, tailored to the user's question. Subjects, consisting of friends or family of hospitalized patients, were asked to "think aloud" as they interacted with the four systems. The evaluation involved audio- and video recording of subject interactions with the interfaces in situ at a hospital. Results of the evaluation show that subjects found Centrifuser's summarization capability useful and easy to understand. In comparing Centrifuser to the three search engines, subjects' ratings varied; however, specific interface features were deemed useful across interfaces. We conclude with a discussion of the implications for engineering Web-based retrieval systems.
NASA Astrophysics Data System (ADS)
Yang, Kun; Xu, Quan-li; Peng, Shuang-yun; Cao, Yan-bo
2008-10-01
Based on the necessity analysis of GIS applications in earthquake disaster prevention, this paper has deeply discussed the spatial integration scheme of urban earthquake disaster loss evaluation models and visualization technologies by using the network development methods such as COM/DCOM, ActiveX and ASP, as well as the spatial database development methods such as OO4O and ArcSDE based on ArcGIS software packages. Meanwhile, according to Software Engineering principles, a solution of Urban Earthquake Emergency Response Decision Support Systems based on GIS technologies have also been proposed, which include the systems logical structures, the technical routes,the system realization methods and function structures etc. Finally, the testing systems user interfaces have also been offered in the paper.
Chaudry, Beenish Moalla; Connelly, Kay; Siek, Katie A; Welch, Janet L
2013-12-01
Chronically ill people, especially those with low literacy skills, often have difficulty estimating portion sizes of liquids to help them stay within their recommended fluid limits. There is a plethora of mobile applications that can help people monitor their nutritional intake but unfortunately these applications require the user to have high literacy and numeracy skills for portion size recording. In this paper, we present two studies in which the low- and the high-fidelity versions of a portion size estimation interface, designed using the cognitive strategies adults employ for portion size estimation during diet recall studies, was evaluated by a chronically ill population with varying literacy skills. The low fidelity interface was evaluated by ten patients who were all able to accurately estimate portion sizes of various liquids with the interface. Eighteen participants did an in situ evaluation of the high-fidelity version incorporated in a diet and fluid monitoring mobile application for 6 weeks. Although the accuracy of the estimation cannot be confirmed in the second study but the participants who actively interacted with the interface showed better health outcomes by the end of the study. Based on these findings, we provide recommendations for designing the next iteration of an accurate and low literacy-accessible liquid portion size estimation mobile interface.
Evaluating Nurses' Satisfaction With Two Nursing Information Systems.
Khajouei, Reza; Abbasi, Reza
2017-06-01
Evaluating user satisfaction is one of the methods to ensure the usability of information systems. Considering the importance of nursing information systems in patient health, the objective of this study is to evaluate nurses' satisfaction with two widely used nursing information systems (Peyvand Dadeh and Tirazhe) in Iran. This descriptive-analytical study was done on 230 nurses in all teaching hospitals of Kerman University of Medical Sciences in 2015. Data were collected using an augmented version of a questionnaire developed by IBM. Data were analyzed by SPSS.16 using descriptive and analytical statistical methods including t test, analysis of variance, and Pearson correlation coefficient. The mean of overall satisfaction with the two systems was 61 ± 2.2 and 74 ± 2.4, respectively. The mean of satisfaction with different systems dimensions, that is, ease of use, information quality, and interface quality, was, respectively, 24 ± 1.9, 26 ± 9.7, and 12 ± 4.7 for Tirazhe and 29 ± 1.1, 39 ± 1.04 and 13 ± 5.3 for Peyvand Dadeh system. Nurses' satisfaction with both systems was at a medium level. The majority of nurses were relatively satisfied with the information quality and user interface quality of these systems. The results suggest that designing nursing information systems in accordance with their users' need improves usability. Hence, policy and decision makers of healthcare institutions should invest on usability when purchasing such systems.
Image pre-processing method for near-wall PIV measurements over moving curved interfaces
NASA Astrophysics Data System (ADS)
Jia, L. C.; Zhu, Y. D.; Jia, Y. X.; Yuan, H. J.; Lee, C. B.
2017-03-01
PIV measurements near a moving interface are always difficult. This paper presents a PIV image pre-processing method that returns high spatial resolution velocity profiles near the interface. Instead of re-shaping or re-orientating the interrogation windows, interface tracking and an image transformation are used to stretch the particle image strips near a curved interface into rectangles. Then the adaptive structured interrogation windows can be arranged at specified distances from the interface. Synthetic particles are also added into the solid region to minimize interfacial effects and to restrict particles on both sides of the interface. Since a high spatial resolution is only required in high velocity gradient region, adaptive meshing and stretching of the image strips in the normal direction is used to improve the cross-correlation signal-to-noise ratio (SN) by reducing the velocity difference and the particle image distortion within the interrogation window. A two dimensional Gaussian fit is used to compensate for the effects of stretching particle images. The working hypothesis is that fluid motion near the interface is ‘quasi-tangential flow’, which is reasonable in most fluid-structure interaction scenarios. The method was validated against the window deformation iterative multi-grid scheme (WIDIM) using synthetic image pairs with different velocity profiles. The method was tested for boundary layer measurements of a supersonic turbulent boundary layer on a flat plate, near a rotating blade and near a flexible flapping flag. This image pre-processing method provides higher spatial resolution than conventional WIDIM and good robustness for measuring velocity profiles near moving interfaces.
Disposable world-to-chip interface for digital microfluidics
Van Dam, R. Michael; Shah, Gaurav; Keng, Pei-Yuin
2017-05-16
The present disclosure sets forth incorporating microfluidic chips interfaces for use with digital microfluidic processes. Methods and devices according to the present disclosure utilize compact, integrated platforms that interface with a chip upstream and downstream of the reaction, as well as between intermediate reaction steps if needed. In some embodiments these interfaces are automated, including automation of a multiple reagent process. Various reagent delivery systems and methods are also disclosed.
A predictive theory of charge separation in organic photovoltaics interfaces
NASA Astrophysics Data System (ADS)
Troisi, Alessandro; Liu, Tao; Caruso, Domenico; Cheung, David L.; McMahon, David P.
2012-09-01
The key process in organic photovoltaics cells is the separation of an exciton, close to the donor/acceptor interface into a free hole (in the donor) and a free electron (in the acceptor). In an efficient solar cell, the majority of absorbed photons generate such hole-electron pairs but it is not clear why such a charge separation process is so efficient in some blends (for example in the blend formed by poly(3- hexylthiophene) (P3HT) and a C60 derivative (PCBM)) and how can one design better OPV materials. The electronic and geometric structure of the prototypical polymer:fullerene interface (P3HT:PCBM) is investigated theoretically using a combination of classical and quantum simulation methods. It is shown that the electronic structure of P3HT in contact with PCBM is significantly altered compared to bulk P3HT. Due to the additional free volume of the interface, P3HT chains close to PCBM are more disordered and, consequently, they are characterized by an increased band gap. Excitons and holes are therefore repelled by the interface. This provides a possible explanation of the low recombination efficiency and supports the direct formation of "quasi-free" charge separated species at the interface. This idea is further explored here by using a more general system-independent model Hamiltonian. The long range exciton dissociation rate is computed as a function of the exciton distance from the interface and the average dissociation distance is evaluated by comparing this rate with the exciton migration rate with a kinetic model. The phenomenological model shows that also in a generic interface the direct formation if quasi-free charges is extremely likely.
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Farooq, Mohammad U.
1986-01-01
The definition of proposed research addressing the development and validation of a methodology for the design and evaluation of user interfaces for interactive information systems is given. The major objectives of this research are: the development of a comprehensive, objective, and generalizable methodology for the design and evaluation of user interfaces for information systems; the development of equations and/or analytical models to characterize user behavior and the performance of a designed interface; the design of a prototype system for the development and administration of user interfaces; and the design and use of controlled experiments to support the research and test/validate the proposed methodology. The proposed design methodology views the user interface as a virtual machine composed of three layers: an interactive layer, a dialogue manager layer, and an application interface layer. A command language model of user system interactions is presented because of its inherent simplicity and structured approach based on interaction events. All interaction events have a common structure based on common generic elements necessary for a successful dialogue. It is shown that, using this model, various types of interfaces could be designed and implemented to accommodate various categories of users. The implementation methodology is discussed in terms of how to store and organize the information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-05-17
PelePhysics is a suite of physics packages that provides functionality of use to reacting hydrodynamics CFD codes. The initial release includes an interface to reaction rate mechanism evaluation, transport coefficient evaluation, and a generalized equation of state (EOS) facility. Both generic evaluators and interfaces to code from externally available tools (Fuego for chemical rates, EGLib for transport coefficients) are provided.
NASA Technical Reports Server (NTRS)
Ding, R. Jeffrey (Inventor)
2012-01-01
A welding method is provided for forming a weld joint between first and second elements of a workpiece. The method includes heating the first and second elements to form an interface of material in a plasticized or melted state interface between the elements. The interface material is then allowed to cool to a plasticized state if previously in a melted state. The interface material, while in the plasticized state, is then mixed, for example, using a grinding/extruding process, to remove any dendritic-type weld microstructures introduced into the interface material during the heating process.
Thermal stir welding apparatus
NASA Technical Reports Server (NTRS)
Ding, R. Jeffrey (Inventor)
2011-01-01
A welding method and apparatus are provided for forming a weld joint between first and second elements of a workpiece. The method includes heating the first and second elements to form an interface of material in a plasticized or melted state interface between the elements. The interface material is then allowed to cool to a plasticized state if previously in a melted state. The interface material, while in the plasticized state, is then mixed, for example, using a grinding/extruding process, to remove any dendritic-type weld microstructures introduced into the interface material during the heating process.
Numerical evaluation of gas core length in free surface vortices
NASA Astrophysics Data System (ADS)
Cristofano, L.; Nobili, M.; Caruso, G.
2014-11-01
The formation and evolution of free surface vortices represent an important topic in many hydraulic intakes, since strong whirlpools introduce swirl flow at the intake, and could cause entrainment of floating matters and gas. In particular, gas entrainment phenomena are an important safety issue for Sodium cooled Fast Reactors, because the introduction of gas bubbles within the core causes dangerous reactivity fluctuation. In this paper, a numerical evaluation of the gas core length in free surface vortices is presented, according to two different approaches. In the first one, a prediction method, developed by the Japanese researcher Sakai and his team, has been applied. This method is based on the Burgers vortex model, and it is able to estimate the gas core length of a free surface vortex starting from two parameters calculated with single-phase CFD simulations. The two parameters are the circulation and the downward velocity gradient. The other approach consists in performing a two-phase CFD simulation of a free surface vortex, in order to numerically reproduce the gas- liquid interface deformation. Mapped convergent mesh is used to reduce numerical error and a VOF (Volume Of Fluid) method was selected to track the gas-liquid interface. Two different turbulence models have been tested and analyzed. Experimental measurements of free surface vortices gas core length have been executed, using optical methods, and numerical results have been compared with experimental measurements. The computational domain and the boundary conditions of the CFD simulations were set consistently with the experimental test conditions.
A comparative study of interface reconstruction methods for multi-material ALE simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kucharik, Milan; Garimalla, Rao; Schofield, Samuel
2009-01-01
In this paper we compare the performance of different methods for reconstructing interfaces in multi-material compressible flow simulations. The methods compared are a material-order-dependent Volume-of-Fluid (VOF) method, a material-order-independent VOF method based on power diagram partitioning of cells and the Moment-of-Fluid method (MOF). We demonstrate that the MOF method provides the most accurate tracking of interfaces, followed by the VOF method with the right material ordering. The material-order-independent VOF method performs some-what worse than the above two while the solutions with VOF using the wrong material order are considerably worse.
The influence of the compression interface on the failure behavior and size effect of concrete
NASA Astrophysics Data System (ADS)
Kampmann, Raphael
The failure behavior of concrete materials is not completely understood because conventional test methods fail to assess the material response independent of the sample size and shape. To study the influence of strength and strain affecting test conditions, four typical concrete sample types were experimentally evaluated in uniaxial compression and analyzed for strength, deformational behavior, crack initiation/propagation, and fracture patterns under varying boundary conditions. Both low friction and conventional compression interfaces were assessed. High-speed video technology was used to monitor macrocracking. Inferential data analysis proved reliably lower strength results for reduced surface friction at the compression interfaces, regardless of sample shape. Reciprocal comparisons revealed statistically significant strength differences between most sample shapes. Crack initiation and propagation was found to differ for dissimilar compression interfaces. The principal stress and strain distributions were analyzed, and the strain domain was found to resemble the experimental results, whereas the stress analysis failed to explain failure for reduced end confinement. Neither stresses nor strains indicated strength reductions due to reduced friction, and therefore, buckling effects were considered. The high-speed video analysis revealed localize buckling phenomena, regardless of end confinement. Slender elements were the result of low friction, and stocky fragments developed under conventional confinement. The critical buckling load increased accordingly. The research showed that current test methods do not reflect the "true'' compressive strength and that concrete failure is strain driven. Ultimate collapse results from buckling preceded by unstable cracking.
Diffuse-Interface Capturing Methods for Compressible Two-Phase Flows
NASA Astrophysics Data System (ADS)
Saurel, Richard; Pantano, Carlos
2018-01-01
Simulation of compressible flows became a routine activity with the appearance of shock-/contact-capturing methods. These methods can determine all waves, particularly discontinuous ones. However, additional difficulties may appear in two-phase and multimaterial flows due to the abrupt variation of thermodynamic properties across the interfacial region, with discontinuous thermodynamical representations at the interfaces. To overcome this difficulty, researchers have developed augmented systems of governing equations to extend the capturing strategy. These extended systems, reviewed here, are termed diffuse-interface models, because they are designed to compute flow variables correctly in numerically diffused zones surrounding interfaces. In particular, they facilitate coupling the dynamics on both sides of the (diffuse) interfaces and tend to the proper pure fluid-governing equations far from the interfaces. This strategy has become efficient for contact interfaces separating fluids that are governed by different equations of state, in the presence or absence of capillary effects, and with phase change. More sophisticated materials than fluids (e.g., elastic-plastic materials) have been considered as well.
Independent Verification and Validation of Complex User Interfaces: A Human Factors Approach
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Berman, Andrea; Chmielewski, Cynthia
1996-01-01
The Usability Testing and Analysis Facility (UTAF) at the NASA Johnson Space Center has identified and evaluated a potential automated software interface inspection tool capable of assessing the degree to which space-related critical and high-risk software system user interfaces meet objective human factors standards across each NASA program and project. Testing consisted of two distinct phases. Phase 1 compared analysis times and similarity of results for the automated tool and for human-computer interface (HCI) experts. In Phase 2, HCI experts critiqued the prototype tool's user interface. Based on this evaluation, it appears that a more fully developed version of the tool will be a promising complement to a human factors-oriented independent verification and validation (IV&V) process.
Lamy, Jean-Baptiste; Venot, Alain; Bar-Hen, Avner; Ouvrard, Patrick; Duclos, Catherine
2008-01-01
Background Drug iatrogeny is important but could be decreased if contraindications, cautions for use, drug interactions and adverse effects of drugs described in drug monographs were taken into account. However, the physician's time is limited during consultations, and this information is often not consulted. We describe here the design of "Mister VCM", a graphical interface based on the VCM graphical language, facilitating access to drug monographs. We also provide an assessment of the usability of this interface. Methods The "Mister VCM" interface was designed by dividing the screen into two parts: a graphical interactive one including VCM icons and synthetizing drug properties, a textual one presenting on demand drug monograph excerpts. The interface was evaluated over 11 volunteer general practitioners, trained in the use of "Mister VCM". They were asked to answer clinical questions related to fictitious randomly generated drug monographs, using a textual interface or "Mister VCM". When answering the questions, correctness of the responses and response time were recorded. Results "Mister VCM" is an interactive interface that displays VCM icons organized around an anatomical diagram of the human body with additional mental, etiological and physiological areas. Textual excerpts of the drug monograph can be displayed by clicking on the VCM icons. The interface can explicitly represent information implicit in the drug monograph, such as the absence of a given contraindication. Physicians made fewer errors with "Mister VCM" than with text (factor of 1.7; p = 0.034) and responded to questions 2.2 times faster (p < 0.001). The time gain with "Mister VCM" was greater for long monographs and questions with implicit replies. Conclusion "Mister VCM" seems to be a promising interface for accessing drug monographs. Similar interfaces could be developed for other medical domains, such as electronic patient records. PMID:18518945
VIPER: a visualisation tool for exploring inheritance inconsistencies in genotyped pedigrees
2012-01-01
Background Pedigree genotype datasets are used for analysing genetic inheritance and to map genetic markers and traits. Such datasets consist of hundreds of related animals genotyped for thousands of genetic markers and invariably contain multiple errors in both the pedigree structure and in the associated individual genotype data. These errors manifest as apparent inheritance inconsistencies in the pedigree, and invalidate analyses of marker inheritance patterns across the dataset. Cleaning raw datasets of bad data points (incorrect pedigree relationships, unreliable marker assays, suspect samples, bad genotype results etc.) requires expert exploration of the patterns of exposed inconsistencies in the context of the inheritance pedigree. In order to assist this process we are developing VIPER (Visual Pedigree Explorer), a software tool that integrates an inheritance-checking algorithm with a novel space-efficient pedigree visualisation, so that reported inheritance inconsistencies are overlaid on an interactive, navigable representation of the pedigree structure. Methods and results This paper describes an evaluation of how VIPER displays the different scales and types of dataset that occur experimentally, with a description of how VIPER's display interface and functionality meet the challenges presented by such data. We examine a range of possible error types found in real and simulated pedigree genotype datasets, demonstrating how these errors are exposed and explored using the VIPER interface and we evaluate the utility and usability of the interface to the domain expert. Evaluation was performed as a two stage process with the assistance of domain experts (geneticists). The initial evaluation drove the iterative implementation of further features in the software prototype, as required by the users, prior to a final functional evaluation of the pedigree display for exploring the various error types, data scales and structures. Conclusions The VIPER display was shown to effectively expose the range of errors found in experimental genotyped pedigrees, allowing users to explore the underlying causes of reported inheritance inconsistencies. This interface will provide the basis for a full data cleaning tool that will allow the user to remove isolated bad data points, and reversibly test the effect of removing suspect genotypes and pedigree relationships. PMID:22607476
Understanding biomaterial-tissue interface quality: combined in vitro evaluation
NASA Astrophysics Data System (ADS)
Gasik, Michael
2017-12-01
One of the greatest challenges in the development of new medical products and devices remains in providing maximal patient safety, efficacy and suitability for the purpose. A 'good quality' of the tissue-implant interface is one of the most critical factors for the success of the implant integration. In this paper this challenge is being discussed from the point of view of basic stimuli combination to experimental testing. The focus is in particular on bacterial effects on tissue-implant interaction (for different materials). The demonstration of the experimental evaluation of the tissue-implant interface is for dental abutment with mucosal contact. This shows that testing of the interface quality could be the most relevant in controlled conditions, which mimic as possible the clinical applications, but consider variables being under the control of the evaluator.
NASA Astrophysics Data System (ADS)
Han, Xiao; Gao, Xiguang; Song, Yingdong
2017-10-01
An approach to identify parameters of interface friction model for Ceramic Matrix composites based on stress-strain response was developed. The stress distribution of fibers in the interface slip region and intact region of the damaged composite was determined by adopting the interface friction model. The relation between maximum strain, secant moduli of hysteresis loop and interface shear stress, interface de-bonding stress was established respectively with the method of symbolic-graphic combination. By comparing the experimental strain, secant moduli of hysteresis loop with computation values, the interface shear stress and interface de-bonding stress corresponding to first cycle were identified. Substituting the identification of parameters into interface friction model, the stress-strain curves were predicted and the predicted results fit experiments well. Besides, the influence of number of data points on identifying the value of interface parameters was discussed. And the approach was compared with the method based on the area of hysteresis loop.
Investigation of test methods, material properties, and processes for solar cell encapsulants
NASA Technical Reports Server (NTRS)
Willis, P. B.
1983-01-01
A study of potentially useful low cost encapsulation materials for the Flat-Plate Solar Array project is discussed. The goal is to identify, evaluate, test and recommend encapsulant materials and processes for the production of cost-effective, long life solar cell modules. Technical investigations included studies of aging and degradation of candidate encapsulation materials, continued identification of primers for durable bonding of module interfaces, continued evaluation of soil resistant treatments for the sunlit surface of the module and testing of corrosion protective coatings for use low cost mild steel substrates.
Space proton transport in one dimension
NASA Technical Reports Server (NTRS)
Lamkin, S. L.; Khandelwal, G. S.; Shinn, J. L.; Wilson, J. W.
1994-01-01
An approximate evaluation procedure is derived for a second-order theory of coupled nucleon transport in one dimension. An analytical solution with a simplified interaction model is used to determine quadrature parameters to minimize truncation error. Effects of the improved method on transport solutions with the BRYNTRN data base are evaluated. Comparisons with Monte Carlo benchmarks are given. Using different shield materials, the computational procedure is used to study the physics of space protons. A transition effect occurs in tissue near the shield interface and is most important in shields of high atomic number.
NASA Astrophysics Data System (ADS)
Moench, Ingo; Peter, Laszlo; Priem, Roland; Sturm, Volker; Noll, Reinhard
1999-09-01
In plants of the chemical, nuclear and off-shore industry, application specific high-alloyed steels are used for pipe fittings. Mixing of different steel grades can lead to corrosion with severe consequential damages. Growing quality requirements and environmental responsibilities demand a 100% material control in the production of the pipe fittings. Therefore, LIFT, an automatic inspection machine, was developed to insure against any mix of material grades. LIFT is able to identify more than 30 different steel grades. The inspection method is based on Laser-Induced Breakdown Spectrometry (LIBS). An expert system, which can be easily trained and recalibrated, was developed for the data evaluation. The result of the material inspection is transferred to an external handling system via a PLC interface. The duration of the inspection process is 2 seconds. The graphical user interface was developed with respect to the requirements of an unskilled operator. The software is based on a realtime operating system and provides a safe and reliable operation. An interface for the remote maintenance by modem enables a fast operational support. Logged data are retrieved and evaluated. This is the basis for an adaptive improvement of the configuration of LIFT with respect to changing requirements in the production line. Within the first six months of routine operation, about 50000 pipe fittings were inspected.
Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction
NASA Astrophysics Data System (ADS)
Liang, Guanghui; Ren, Shangjie; Dong, Feng
2017-07-01
The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak interfaces that are associated with... according to the procedures in Method 21 of 40 CFR part 60, appendix A. (7) Each potential leak interface...
Cognitive Task Analysis, Interface Design, and Technical Troubleshooting.
ERIC Educational Resources Information Center
Steinberg, Linda S.; Gitomer, Drew H.
A model of the interface design process is proposed that makes use of two interdependent levels of cognitive analysis: the study of the criterion task through an analysis of expert/novice differences and the evaluation of the working user interface design through the application of a practical interface analysis methodology (GOMS model). This dual…
NASA Astrophysics Data System (ADS)
Heitzer, Joerg
1992-05-01
Two methods for the numerical solution of the integral equation describing the kinked interface crack, one proposed by Erdogan et al. (1973) and the other by Theokaris and Iokimidis (1979), are examined. The method of Erdogan et al. is then used to solve the equation in order to determine the kinking angle of the interface crack. Results are presented for two material combinations, aluminum/epoxy and glass/ceramic, under uniaxial tension in the direction normal to the interface.
Szostak, Katarzyna M.; Grand, Laszlo; Constandinou, Timothy G.
2017-01-01
Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes—microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges. PMID:29270103
Szostak, Katarzyna M; Grand, Laszlo; Constandinou, Timothy G
2017-01-01
Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes-microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges.
Fast Implicit Methods For Elliptic Moving Interface Problems
2015-12-11
analyzed, and tested for the Fourier transform of piecewise polynomials given on d-dimensional simplices in D-dimensional Euclidean space. These transforms...evaluation, and one to three orders of magnitude slower than the classical uniform Fast Fourier Transform. Second, bilinear quadratures ---which...a fast algorithm was derived, analyzed, and tested for the Fourier transform of pi ecewise polynomials given on d-dimensional simplices in D
Kneeshaw, T.A.; McGuire, J.T.; Smith, E.W.; Cozzarelli, I.M.
2007-01-01
This paper presents small-scale push-pull tests designed to evaluate the kinetic controls on SO42 - reduction in situ at mixing interfaces between a wetland and aquifer impacted by landfill leachate at the Norman Landfill research site, Norman, OK. Quantifying the rates of redox reactions initiated at interfaces is of great interest because interfaces have been shown to be zones of increased biogeochemical transformations and thus may play an important role in natural attenuation. To mimic the aquifer-wetland interface and evaluate reaction rates, SO42 --rich anaerobic aquifer water (??? 100 mg / L SO42 -) was introduced into SO42 --depleted wetland porewater via push-pull tests. Results showed SO42 - reduction was stimulated by the mixing of these waters and first-order rate coefficients were comparable to those measured in other push-pull studies. However, rate data were complex involving either multiple first-order rate coefficients or a more complex rate order. In addition, a lag phase was observed prior to SO42 - reduction that persisted until the mixing interface between test solution and native water was recovered, irrespective of temporal and spatial constraints. The lag phase was not eliminated by the addition of electron donor (acetate) to the injected test solution. Subsequent push-pull tests designed to elucidate the nature of the lag phase support the importance of the mixing interface in controlling terminal electron accepting processes. These data suggest redox reactions may occur rapidly at the mixing interface between injected and native waters but not in the injected bulk water mass. Under these circumstances, push-pull test data should be evaluated to ensure the apparent rate is actually a function of time and that complexities in rate data be considered. ?? 2007 Elsevier Ltd. All rights reserved.
Review of the socket design and interface pressure measurement for transtibial prosthesis.
Pirouzi, Gh; Abu Osman, N A; Eshraghi, A; Ali, S; Gholizadeh, H; Wan Abas, W A B
2014-01-01
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations.
Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis
Pirouzi, Gh.; Abu Osman, N. A.; Eshraghi, A.; Ali, S.; Gholizadeh, H.; Wan Abas, W. A. B.
2014-01-01
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations. PMID:25197716
The protein-protein interface evolution acts in a similar way to antibody affinity maturation.
Li, Bohua; Zhao, Lei; Wang, Chong; Guo, Huaizu; Wu, Lan; Zhang, Xunming; Qian, Weizhu; Wang, Hao; Guo, Yajun
2010-02-05
Understanding the evolutionary mechanism that acts at the interfaces of protein-protein complexes is a fundamental issue with high interest for delineating the macromolecular complexes and networks responsible for regulation and complexity in biological systems. To investigate whether the evolution of protein-protein interface acts in a similar way as antibody affinity maturation, we incorporated evolutionary information derived from antibody affinity maturation with common simulation techniques to evaluate prediction success rates of the computational method in affinity improvement in four different systems: antibody-receptor, antibody-peptide, receptor-membrane ligand, and receptor-soluble ligand. It was interesting to find that the same evolutionary information could improve the prediction success rates in all the four protein-protein complexes with an exceptional high accuracy (>57%). One of the most striking findings in our present study is that not only in the antibody-combining site but in other protein-protein interfaces almost all of the affinity-enhancing mutations are located at the germline hotspot sequences (RGYW or WA), indicating that DNA hot spot mechanisms may be widely used in the evolution of protein-protein interfaces. Our data suggest that the evolution of distinct protein-protein interfaces may use the same basic strategy under selection pressure to maintain interactions. Additionally, our data indicate that classical simulation techniques incorporating the evolutionary information derived from in vivo antibody affinity maturation can be utilized as a powerful tool to improve the binding affinity of protein-protein complex with a high accuracy.
Kontis, Angelo L.
1999-01-01
The seaward limit of the fresh ground-water system underlying Kings and Queens Counties on Long Island, N.Y., is at the freshwater-saltwater transition zone. This zone has been conceptualized in transient-state, three-dimensional models of the aquifer system as a sharp interface between freshwater and saltwater, and represented as a stationary, zero lateral-flow boundary. In this study, a pair of two-dimensional, four-layer ground-water flow models representing a generalized vertical section in Kings County and one in adjacent Queens County were developed to evaluate the validity of the boundary condition used in three-dimensional models of the aquifer system. The two-dimensional simulations used a model code that can simulate the movement of a sharp interface in response to transient stress. Sensitivity of interface movement to four factors was analyzed; these were (1) the method of simulating vertical leakage between freshwater and saltwater; (2) recharge at the normal rate, at 50-percent of the normal rate, and at zero for a prolonged (3-year) period; (3) high, medium, and low pumping rates; and (4) pumping from a hypothetical cluster of wells at two locations. Results indicate that the response of the interfaces to the magnitude and duration of pumping and the location of the hypothetical wells is probably sufficiently slow that the interfaces in three-dimensional models can reasonably be approximated as stationary, zero-lateral- flow boundaries.
Systems Maintenance Automated Repair Tasks (SMART)
NASA Technical Reports Server (NTRS)
2008-01-01
SMART is an interactive decision analysis and refinement software system that uses evaluation criteria for discrepant conditions to automatically provide and populate a document/procedure with predefined steps necessary to repair a discrepancy safely, effectively, and efficiently. SMART can store the tacit (corporate) knowledge merging the hardware specification requirements with the actual "how to" repair methods, sequences, and required equipment, all within a user-friendly interface. Besides helping organizations retain repair knowledge in streamlined procedures and sequences, SMART can also help them in saving processing time and expense, increasing productivity, improving quality, and adhering more closely to safety and other guidelines. Though SMART was developed for Space Shuttle applications, its interface is easily adaptable to any hardware that can be broken down by component, subcomponent, discrepancy, and repair.
Test method research on weakening interface strength of steel - concrete under cyclic loading
NASA Astrophysics Data System (ADS)
Liu, Ming-wei; Zhang, Fang-hua; Su, Guang-quan
2018-02-01
The mechanical properties of steel - concrete interface under cyclic loading are the key factors affecting the rule of horizontal load transfer, the calculation of bearing capacity and cumulative horizontal deformation. Cyclic shear test is an effective method to study the strength reduction of steel - concrete interface. A test system composed of large repeated direct shear test instrument, hydraulic servo system, data acquisition system, test control software system and so on is independently designed, and a set of test method, including the specimen preparation, the instrument preparation, the loading method and so on, is put forward. By listing a set of test results, the validity of the test method is verified. The test system and the test method based on it provide a reference for the experimental study on mechanical properties of steel - concrete interface.
Improvement of design of a surgical interface using an eye tracking device
2014-01-01
Background Surgical interfaces are used for helping surgeons in interpretation and quantification of the patient information, and for the presentation of an integrated workflow where all available data are combined to enable optimal treatments. Human factors research provides a systematic approach to design user interfaces with safety, accuracy, satisfaction and comfort. One of the human factors research called user-centered design approach is used to develop a surgical interface for kidney tumor cryoablation. An eye tracking device is used to obtain the best configuration of the developed surgical interface. Methods Surgical interface for kidney tumor cryoablation has been developed considering the four phases of user-centered design approach, which are analysis, design, implementation and deployment. Possible configurations of the surgical interface, which comprise various combinations of menu-based command controls, visual display of multi-modal medical images, 2D and 3D models of the surgical environment, graphical or tabulated information, visual alerts, etc., has been developed. Experiments of a simulated cryoablation of a tumor task have been performed with surgeons to evaluate the proposed surgical interface. Fixation durations and number of fixations at informative regions of the surgical interface have been analyzed, and these data are used to modify the surgical interface. Results Eye movement data has shown that participants concentrated their attention on informative regions more when the number of displayed Computer Tomography (CT) images has been reduced. Additionally, the time required to complete the kidney tumor cryoablation task by the participants had been decreased with the reduced number of CT images. Furthermore, the fixation durations obtained after the revision of the surgical interface are very close to what is observed in visual search and natural scene perception studies suggesting more efficient and comfortable interaction with the surgical interface. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) and Short Post-Assessment Situational Awareness (SPASA) questionnaire results have shown that overall mental workload of surgeons related with surgical interface has been low as it has been aimed, and overall situational awareness scores of surgeons have been considerably high. Conclusions This preliminary study highlights the improvement of a developed surgical interface using eye tracking technology to obtain the best SI configuration. The results presented here reveal that visual surgical interface design prepared according to eye movement characteristics may lead to improved usability. PMID:25080176
The Evaluation of Two CDU Concepts and Their Effects on FMS Training
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
1995-01-01
One of the biggest challenges for a pilot in the transition to a "glass" cockpit is understanding the Flight Management System (FMS). This is due to both the complex nature of the FMS and to the pilot-FMS interface. For these reasons, a large portion of transition training is devoted to the FMS. The intent of the current study was to examine the impact of the primary pilot-FMS interface, the Control Display Unit (CDU), on FMS training. The hypothesis of this study was that the interface design could have a significant impact on training. An FMS simulation was developed with two separate interfaces. One interface was similar to a current-generation design and the other was a multi-windows CDU based on graphical user interface techniques. For both application and evaluation reasons, constraints were applied to the graphical CDU design to maintain as much similarity as possible with the conventional CDU.
A meta-analysis of human-system interfaces in unmanned aerial vehicle (UAV) swarm management.
Hocraffer, Amy; Nam, Chang S
2017-01-01
A meta-analysis was conducted to systematically evaluate the current state of research on human-system interfaces for users controlling semi-autonomous swarms composed of groups of drones or unmanned aerial vehicles (UAVs). UAV swarms pose several human factors challenges, such as high cognitive demands, non-intuitive behavior, and serious consequences for errors. This article presents findings from a meta-analysis of 27 UAV swarm management papers focused on the human-system interface and human factors concerns, providing an overview of the advantages, challenges, and limitations of current UAV management interfaces, as well as information on how these interfaces are currently evaluated. In general allowing user and mission-specific customization to user interfaces and raising the swarm's level of autonomy to reduce operator cognitive workload are beneficial and improve situation awareness (SA). It is clear more research is needed in this rapidly evolving field. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gestures in an Intelligent User Interface
NASA Astrophysics Data System (ADS)
Fikkert, Wim; van der Vet, Paul; Nijholt, Anton
In this chapter we investigated which hand gestures are intuitive to control a large display multimedia interface from a user's perspective. Over the course of two sequential user evaluations, we defined a simple gesture set that allows users to fully control a large display multimedia interface, intuitively. First, we evaluated numerous gesture possibilities for a set of commands that can be issued to the interface. These gestures were selected from literature, science fiction movies, and a previous exploratory study. Second, we implemented a working prototype with which the users could interact with both hands and the preferred hand gestures with 2D and 3D visualizations of biochemical structures. We found that the gestures are influenced to significant extent by the fast paced developments in multimedia interfaces such as the Apple iPhone and the Nintendo Wii and to no lesser degree by decades of experience with the more traditional WIMP-based interfaces.
Morita, Yutaka; Tsushima, Yuki; Yasui, Masanobu; Termoz, Ryoji; Ajioka, Junko; Takayama, Kozo
2002-09-01
Many kinds of rapidly disintegrating or oral disintegrating tablets (RDT) have been developed to improve the ease of tablet administration, especially for elderly and pediatric patients. In these cases, knowledge regarding disintegration behavior appears important with respect to the development of such a novel tablet. Ordinary disintegration testing, such as the Japanese Pharmacopoeia (JP) method, faces limitations with respect to the evaluation of rapid disintegration due to strong agitation. Therefore, we have developed a novel apparatus and method to determine the dissolution of the RDT. The novel device consists of a disintegrating bath and CCD camera interfaced with a personal computer equipped with motion capture and image analysis software. A newly developed RDT containing various types of binder was evaluated with this protocol. In this method, disintegration occurs in a mildly agitated medium, which allows differentiation of minor distinctions among RDTs of different formulations. Simultaneously, we were also able to detect qualitative information, i.e., morphological changes in the tablet during disintegration. This method is useful for the evaluation of the disintegration of RDT during pharmaceutical development, and also for quality control during production.
A feasible method to eliminate nanoleakage in dentin hybrid layers.
Chen, Ji-Hua; Liu, Yan; Niu, Li-Na; Lu, Shuai; Tay, Franklin R; Gao, Yu
2014-10-01
To determine whether high-pressure air blowing during adhesive application affects the infiltration of resin comonomers and nanoleakage manifestation in the resin/dentin interface under simulated pulpal pressure. Thirty mid-coronal dentin surfaces were bonded with an etch-and-rinse adhesive (Adper Single Bond 2) under simulated pulpal pressure. In the control group, the adhesive was thinned by ordinary air blowing with a pressure of 0.2 MPa, while in the experimental group, a high-pressure air blowing technique (pressure: 0.4 MPa) was used. All other procedures followed the manufacturer's instructions. Resin tag formation and nanoleakage in the bonding interface were evaluated with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). When adhesive was thinned with high pressure air blowing, longer and more homogeneous resin tags were formed. The bonding interface demonstrated good overall morphology and integrity. Almost perfect infiltration of resin and no obvious nanoleakage were observed. Thinning of adhesive with high-pressure air blowing provides a clinically feasible adjunctive procedure for better resin infiltration.
Diefenbeck, Michael; Mückley, Thomas; Zankovych, Sergiy; Bossert, Jörg; Jandt, Klaus D; Schrader, Christian; Schmidt, Jürgen; Finger, Ulrich; Faucon, Mathilde
2011-01-01
Background: The effects of freezing-thawing cycles on intramedullary bone-implant interfaces have been studied in a rat model in mechanical pull-out tests. Implants: Twenty TiAl6V4 rods (Ø 0.8 mm, length 10 mm) implanted in rat tibiae Methods: 10 rats underwent bilateral tibial implantation of titanium rods. At eight weeks, the animals were sacrificed and tibiae harvested for biomechanical testing. Eight tibiae were frozen and stored at -20°C for 14 days, the remaining eight were evaluated immediately post-harvest. Pull-out tests were used to determine maximum force and interfacial shear strength. Results: There were no significant differences between fresh and those of the frozen-thawed group in maximum force or in interfacial shear strength. Conclusion: Frozen Storage of rat tibiae containing implants at -20° C has no effects on the biomechanical properties of Bone/ Implant interface. PMID:21760868
Contact angle distribution of particles at fluid interfaces.
Snoeyink, Craig; Barman, Sourav; Christopher, Gordon F
2015-01-27
Recent measurements have implied a distribution of interfacially adsorbed particles' contact angles; however, it has been impossible to measure statistically significant numbers for these contact angles noninvasively in situ. Using a new microscopy method that allows nanometer-scale resolution of particle's 3D positions on an interface, we have measured the contact angles for thousands of latex particles at an oil/water interface. Furthermore, these measurements are dynamic, allowing the observation of the particle contact angle with high temporal resolution, resulting in hundreds of thousands of individual contact angle measurements. The contact angle has been found to fit a normal distribution with a standard deviation of 19.3°, which is much larger than previously recorded. Furthermore, the technique used allows the effect of measurement error, constrained interfacial diffusion, and particle property variation on the contact angle distribution to be individually evaluated. Because of the ability to measure the contact angle noninvasively, the results provide previously unobtainable, unique data on the dynamics and distribution of the adsorbed particles' contact angle.
Glass microfluidic devices with thin membrane voltage junctions for electrospray mass spectrometry.
Yue, Guihua Eileen; Roper, Michael G; Jeffery, Erin D; Easley, Christopher J; Balchunas, Catherine; Landers, James P; Ferrance, Jerome P
2005-06-01
In this study a novel glass membrane was prepared for conducting high voltage (HV) to solution in the channel of a microfabricated device for generation of liquid electrospray. Taylor cone formation and mass spectra obtained from this microdevice confirmed the utility of the glass membrane, but voltage conduction through the membrane could not be successfully explained based solely on the conductivity of the glass itself. This novel method for developing a high-voltage interface for microdevices avoids direct metal/liquid contact eliminating bubble formation in the channel due to water hydrolysis on the surface of the metal. Further, this arrangement produces no dead volume as is often found with traditional liquid junctions. At the same time, preliminary investigations into the outlet design of glass microdevices for interfacing with electrospray mass spectrometry, was explored. Both the exit shape and the use of hydrophobic coatings at the channel exit of the microdevice electrospray interface were evaluated using standard proteins with results indicating the utility of this type of design after further optimization.
Yandell, Matthew B; Quinlivan, Brendan T; Popov, Dmitry; Walsh, Conor; Zelik, Karl E
2017-05-18
Wearable assistive devices have demonstrated the potential to improve mobility outcomes for individuals with disabilities, and to augment healthy human performance; however, these benefits depend on how effectively power is transmitted from the device to the human user. Quantifying and understanding this power transmission is challenging due to complex human-device interface dynamics that occur as biological tissues and physical interface materials deform and displace under load, absorbing and returning power. Here we introduce a new methodology for quickly estimating interface power dynamics during movement tasks using common motion capture and force measurements, and then apply this method to quantify how a soft robotic ankle exosuit interacts with and transfers power to the human body during walking. We partition exosuit end-effector power (i.e., power output from the device) into power that augments ankle plantarflexion (termed augmentation power) vs. power that goes into deformation and motion of interface materials and underlying soft tissues (termed interface power). We provide empirical evidence of how human-exosuit interfaces absorb and return energy, reshaping exosuit-to-human power flow and resulting in three key consequences: (i) During exosuit loading (as applied forces increased), about 55% of exosuit end-effector power was absorbed into the interfaces. (ii) However, during subsequent exosuit unloading (as applied forces decreased) most of the absorbed interface power was returned viscoelastically. Consequently, the majority (about 75%) of exosuit end-effector work over each stride contributed to augmenting ankle plantarflexion. (iii) Ankle augmentation power (and work) was delayed relative to exosuit end-effector power, due to these interface energy absorption and return dynamics. Our findings elucidate the complexities of human-exosuit interface dynamics during transmission of power from assistive devices to the human body, and provide insight into improving the design and control of wearable robots. We conclude that in order to optimize the performance of wearable assistive devices it is important, throughout design and evaluation phases, to account for human-device interface dynamics that affect power transmission and thus human augmentation benefits.
Zahnd, Guillaume; Kapellas, Kostas; van Hattem, Martijn; van Dijk, Anouk; Sérusclat, André; Moulin, Philippe; van der Lugt, Aad; Skilton, Michael; Orkisz, Maciej
2017-01-01
The aim of this study was to introduce and evaluate a contour segmentation method to extract the interfaces of the intima-media complex in carotid B-mode ultrasound images. The method was applied to assess the temporal variation of intima-media thickness during the cardiac cycle. The main methodological contribution of the proposed approach is the introduction of an augmented dimension to process 2-D images in a 3-D space. The third dimension, which is added to the two spatial dimensions of the image, corresponds to the tentative local thickness of the intima-media complex. The method is based on a dynamic programming scheme that runs in a 3-D space generated with a shape-adapted filter bank. The optimal solution corresponds to a single medial axis representation that fully describes the two anatomical interfaces of the arterial wall. The method is fully automatic and does not require any input from the user. The method was trained on 60 subjects and validated on 184 other subjects from six different cohorts and four different medical centers. The arterial wall was successfully segmented in all analyzed images (average pixel size = 57 ± 20 mm), with average segmentation errors of 47 ± 70 mm for the lumen-intima interface, 55 ± 68 mm for the media-adventitia interface and 66 ± 90 mm for the intima-media thickness. The amplitude of the temporal variations in IMT during the cardiac cycle was significantly higher in the diseased population than in healthy volunteers (106 ± 48 vs. 86 ± 34 mm, p = 0.001). The introduced framework is a promising approach to investigate an emerging functional parameter of the arterial wall by assessing the cyclic compression-decompression pattern of the tissues. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
2017-01-01
Purpose To retrospectively evaluate the relationship between the vertical position of the implant-abutment interface and marginal bone loss over 3 years using radiological analysis. Methods In total, 286 implant surfaces of 143 implants from 61 patients were analyzed. Panoramic radiographic images were taken immediately after implant installation and at 6, 12, and 36 months after loading. The implants were classified into 3 groups based on the vertical position of the implant-abutment interface: group A (above bone level), group B (at bone level), and group C (below bone level). The radiographs were analyzed by a single examiner. Results Changes in marginal bone levels of 0.99±1.45, 1.13±0.91, and 1.76±0.78 mm were observed at 36 months after loading in groups A, B, and C, respectively, and bone loss was significantly greater in group C than in groups A and B. Conclusions The vertical position of the implant-abutment interface may affect marginal bone level change. Marginal bone loss was significantly greater in cases where the implant-abutment interface was positioned below the marginal bone. Further long-term study is required to validate our results. PMID:28861287
Structural Integrity Testing Method for PRSEUS Rod-Wrap Stringer Design
NASA Technical Reports Server (NTRS)
Wang, John T.; Grenoble, Ray W.; Pickell, Robert D.
2012-01-01
NASA Langley Research Center and The Boeing Company are developing an innovative composite structural concept, called PRSEUS, for the flat center section of a future environmentally friendly hybrid wing body (HWB) aircraft. The PRSEUS (Pultruded Rod Stitched Efficient Unitized Structure) concept uses dry textile preforms for the skins, frames, and stiffener webs. The highly loaded stiffeners are made from precured unidirectional carbon/epoxy rods and dry fiber preforms. The rods are wrapped with the dry fiber preforms and a resin infusion process is used to form the rod-wrap stiffeners. The structural integrity of the rod-wrap interface is critical for maintaining the panel s high strength and bending rigidity. No standard testing method exists for testing the strength of the rod-wrap bondline. Recently, Boeing proposed a rod push-out testing method and conducted some preliminary tests using this method. This paper details an analytical study of the rod-wrap bondline. The rod-wrap interface is modeled as a cohesive zone for studying the initiation and growth of interfacial debonding during push-out testing. Based on the correlations of analysis results and Boeing s test data, the adequacy of the rod-wrap testing method is evaluated, and potential approaches for improvement of the test method are proposed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, L.H., E-mail: Luhui.Han@tum.de; Hu, X.Y., E-mail: Xiangyu.Hu@tum.de; Adams, N.A., E-mail: Nikolaus.Adams@tum.de
In this paper we present a scale separation approach for multi-scale modeling of free-surface and two-phase flows with complex interface evolution. By performing a stimulus-response operation on the level-set function representing the interface, separation of resolvable and non-resolvable interface scales is achieved efficiently. Uniform positive and negative shifts of the level-set function are used to determine non-resolvable interface structures. Non-resolved interface structures are separated from the resolved ones and can be treated by a mixing model or a Lagrangian-particle model in order to preserve mass. Resolved interface structures are treated by the conservative sharp-interface model. Since the proposed scale separationmore » approach does not rely on topological information, unlike in previous work, it can be implemented in a straightforward fashion into a given level set based interface model. A number of two- and three-dimensional numerical tests demonstrate that the proposed method is able to cope with complex interface variations accurately and significantly increases robustness against underresolved interface structures.« less
Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain
2016-10-01
Audit and Feedback (A&F) is a widely used quality improvement technique that measures clinicians' clinical performance and reports it back to them. Computerised A&F (e-A&F) system interfaces may consist of four key components: (1) Summaries of clinical performance; (2) Patient lists; (3) Patient-level data; (4) Recommended actions. There is a lack of evidence regarding how to best design e-A&F interfaces; establishing such evidence is key to maximising usability, and in turn improving patient safety. To evaluate the usability of a novel theoretically-informed and research-led e-A&F system for primary care (the Performance Improvement plaN GeneratoR: PINGR). (1) Describe PINGR's design, rationale and theoretical basis; (2) Identify usability issues with PINGR; (3) Understand how these issues may interfere with the cognitive goals of end-users; (4) Translate the issues into recommendations for the user-centred design of e-A&F systems. Eight experienced health system evaluators performed a usability inspection using an innovative hybrid approach consisting of five stages: (1) Development of representative user tasks, Goals, and Actions; (2) Combining Heuristic Evaluation and Cognitive Walkthrough methods into a single protocol to identify usability issues; (3) Consolidation of issues; (4) Severity rating of consolidated issues; (5) Analysis of issues according to usability heuristics, interface components, and Goal-Action structure. A final list of 47 issues were categorised into 8 heuristic themes. The most error-prone heuristics were 'Consistency and standards' (13 usability issues; 28% of the total) and 'Match between system and real world' (n=10, 21%). The recommended actions component of the PINGR interface had the most usability issues (n=21, 45%), followed by patient-level data (n=5, 11%), patient lists (n=4, 9%), and summaries of clinical performance (n=4, 9%). The most error-prone Actions across all user Goals were: (1) Patient selection from a list; (2) Data identification from a figure (both population-level and patient-level); (3) Disagreement with a system recommendation. By contextualising our findings within the wider literature on health information system usability, we provide recommendations for the design of e-A&F system interfaces relating to their four key components, in addition to how they may be integrated within a system. Copyright © 2016. Published by Elsevier Ireland Ltd.
Implementing a Quantitative Analysis Design Tool for Future Generation Interfaces
2012-03-01
with Remotely Piloted Aircraft (RPA) has resulted in the need of a platform to evaluate interface design. The Vigilant Spirit Control Station ( VSCS ...Spirit interface. A modified version of the HCI Index was successfully applied to perform a quantitative analysis of the baseline VSCS interface and...time of the original VSCS interface. These results revealed the effectiveness of the tool and demonstrated in the design of future generation
Design and evaluation of web-based image transmission and display with different protocols
NASA Astrophysics Data System (ADS)
Tan, Bin; Chen, Kuangyi; Zheng, Xichuan; Zhang, Jianguo
2011-03-01
There are many Web-based image accessing technologies used in medical imaging area, such as component-based (ActiveX Control) thick client Web display, Zerofootprint thin client Web viewer (or called server side processing Web viewer), Flash Rich Internet Application(RIA) ,or HTML5 based Web display. Different Web display methods have different peformance in different network environment. In this presenation, we give an evaluation on two developed Web based image display systems. The first one is used for thin client Web display. It works between a PACS Web server with WADO interface and thin client. The PACS Web server provides JPEG format images to HTML pages. The second one is for thick client Web display. It works between a PACS Web server with WADO interface and thick client running in browsers containing ActiveX control, Flash RIA program or HTML5 scripts. The PACS Web server provides native DICOM format images or JPIP stream for theses clients.
Williams, Kent E; Voigt, Jeffrey R
2004-01-01
The research reported herein presents the results of an empirical evaluation that focused on the accuracy and reliability of cognitive models created using a computerized tool: the cognitive analysis tool for human-computer interaction (CAT-HCI). A sample of participants, expert in interacting with a newly developed tactical display for the U.S. Army's Bradley Fighting Vehicle, individually modeled their knowledge of 4 specific tasks employing the CAT-HCI tool. Measures of the accuracy and consistency of task models created by these task domain experts using the tool were compared with task models created by a double expert. The findings indicated a high degree of consistency and accuracy between the different "single experts" in the task domain in terms of the resultant models generated using the tool. Actual or potential applications of this research include assessing human-computer interaction complexity, determining the productivity of human-computer interfaces, and analyzing an interface design to determine whether methods can be automated.
Development and Evaluation of the Method with an Affective Interface for Promoting Employees' Morale
NASA Astrophysics Data System (ADS)
Fujino, Hidenori; Ishii, Hirotake; Shimoda, Hiroshi; Yoshikawa, Hidekazu
For the sustainable society, organization management not based on the mass production and mass consumption but having the flexibility to meet to various social needs precisely is required. For realizing such management, the emploees' work morale is required. Recently, however, the emploees' work morale is tend to decrease. Therefore, in this study, the authors developed the model of the method for promoting and keeping employees' work morale effectively and efficiently. Especially the authors thought “work morale” of “attitude to the work”. Based on this idea, it could be considered that the theory of the persuasion psychology and various persuasion techniques. Therefore, the model of the method applying the character agent was developed based on the forced compliance which is one of persuasion techniques based on the theory of the cognitive dissonance. By the evaluation experiment using human subjects, it was confirmed that developed method could improve workers' work morle effectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy
2012-11-15
Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measuremore » of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was Less-Than-Or-Slanted-Equal-To 3 mm (95th percentiles within {+-}4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from -0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of Less-Than-Or-Slanted-Equal-To 5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance.« less
Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M.; Tempany, Clare M.; Cormack, Robert A.
2012-01-01
Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was ⩽3 mm (95th percentiles within ±4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from −0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of ⩽5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance. PMID:23127078
NASA Technical Reports Server (NTRS)
Gundersen, R. T.; Bond, R. L.
1976-01-01
Zero-g workstations were designed throughout manned spaceflight, based on different criteria and requirements for different programs. The history of design of these workstations is presented along with a thorough evaluation of selected Skylab workstations (the best zero-g experience available on the subject). The results were applied to on-going and future programs, with special emphasis on the correlation of neutral body posture in zero-g to workstation design. Where selected samples of shuttle orbiter workstations are shown as currently designed and compared to experience gained during prior programs in terms of man machine interface design, the evaluations were done in a generic sense to show the methods of applying evaluative techniques.
Effects of different artificial ageing methods on the degradation of adhesive-dentine interfaces.
Deng, Donglai; Yang, Hongye; Guo, Jingmei; Chen, Xiaohui; Zhang, Weiping; Huang, Cui
2014-12-01
To compare the effects of four commonly used artificial ageing methods (water storage, thermocycling, NaOCl storage and pH cycling) on the degradation of adhesive-dentine interfaces. Fifty molars were sectioned parallel to the occlusal plane, polished and randomly divided into two adhesive groups: An etch-and-rinse adhesive Adper SingleBond 2 and a self-etch adhesive G-Bond. After the composite built up, the specimens from each adhesive group were sectioned into beams, which were then assigned to one of the following groups: Group 1 (control), 24h of water storage; Group 2, 6 months of water storage; Group 3, 10,000 runs of thermocycling; Group 4, 1h of 10% NaOCl storage; and Group 5, 15 runs of pH cycling. The microtensile bond strengths were then tested. The failure modes were classified with a stereomicroscope and representative interface was analyzed with a field-emission scanning electron microscopy (FESEM). Nanoleakage expression was evaluated through FESEM in the backscattered mode. The four artificial ageing methods decreased the bonding strength to nearly 50% and increased the nanoleakage expression of both adhesive systems compared with the control treatment. Adhesive failures were the predominant fracture modes in all groups. However, differences in detailed morphology were observed among the different groups. Water storage, thermocycling, NaOCl storage and pH cycling could obtain similar degradation effectiveness through appropriate parameter selection. Each in vitro artificial ageing method had its own mechanisms, characteristics and application scope for degrading the adhesive-dentin interfaces. Water storage is simple, low-cost but time-consuming; thermocycling lacks of a standard agreement; NaOCl storage is time-saving but mainly degrades the organic phase; pH cycling can resemble cariogenic condition but needs further studies. Researchers focusing on bonding durability studies should be deliberate in selecting an appropriate ageing model based on the differences of test material, purpose and time. Copyright © 2014 Elsevier Ltd. All rights reserved.
Design of a haptic device with grasp and push-pull force feedback for a master-slave surgical robot.
Hu, Zhenkai; Yoon, Chae-Hyun; Park, Samuel Byeongjun; Jo, Yung-Ho
2016-07-01
We propose a portable haptic device providing grasp (kinesthetic) and push-pull (cutaneous) sensations for optical-motion-capture master interfaces. Although optical-motion-capture master interfaces for surgical robot systems can overcome the stiffness, friction, and coupling problems of mechanical master interfaces, it is difficult to add haptic feedback to an optical-motion-capture master interface without constraining the free motion of the operator's hands. Therefore, we utilized a Bowden cable-driven mechanism to provide the grasp and push-pull sensation while retaining the free hand motion of the optical-motion capture master interface. To evaluate the haptic device, we construct a 2-DOF force sensing/force feedback system. We compare the sensed force and the reproduced force of the haptic device. Finally, a needle insertion test was done to evaluate the performance of the haptic interface in the master-slave system. The results demonstrate that both the grasp force feedback and the push-pull force feedback provided by the haptic interface closely matched with the sensed forces of the slave robot. We successfully apply our haptic interface in the optical-motion-capture master-slave system. The results of the needle insertion test showed that our haptic feedback can provide more safety than merely visual observation. We develop a suitable haptic device to produce both kinesthetic grasp force feedback and cutaneous push-pull force feedback. Our future research will include further objective performance evaluations of the optical-motion-capture master-slave robot system with our haptic interface in surgical scenarios.
Control of interface shape during high melting sesquioxide crystal growth by HEM technique
NASA Astrophysics Data System (ADS)
Hu, Kaiwei; Zheng, Lili; Zhang, Hui
2018-02-01
During crystal growth in heat exchanger method (HEM) system, the shape of the growth interface changes with the proceeding of the growth process, which limits the crystal size and reduces the quality of the crystal. In this paper, a modified HEM system is proposed to control the interface shape for growth of sesquioxide crystals. Numerical simulation is performed to predict heat transfer, melt flow and interface shape during growth of high melting sesquioxide crystals by the heat exchanger method. The results show that a flat or slightly convex interface shape is beneficial to reduce the solute pileup in front of the melt/crystal interface and decrease the radial temperature gradient inside the crystal during growth of sesquioxide crystals. The interface shape can be controlled by adjusting the gap size d and lower resistance heater power during growth. The growth rate and the melt/crystal interface position can be obtained by two measured temperatures.
Cauchy integral method for two-dimensional solidification interface shapes
NASA Astrophysics Data System (ADS)
Siegel, R.; Sosoka, D. J.
1982-07-01
A method is developed to determine the shape of steady state solidification interfaces formed when liquid above its freezing point circulates over a cold surface. The solidification interface, which is at uniform temperature, will form in a shape such that the non-uniform energy convected to it is locally balanced by conduction into the solid. The interface shape is of interest relative to the crystal structure formed during solidification; regulating the crystal structure has application in casting naturally strengthened metallic composites. The results also pertain to phase-change energy storage devices, where the solidified configuration and overall heat transfer are needed. The analysis uses a conformal mapping technique to relate the desired interface coordinates to the components of the temperature gradient at the interface. These components are unknown because the interface shape is unknown. A Cauchy integral formulation provides a second relation involving the components, and a simultaneous solution yields the interface shape.
Development of an aeroelastic methodology for surface morphing rotors
NASA Astrophysics Data System (ADS)
Cook, James R.
Helicopter performance capabilities are limited by maximum lift characteristics and vibratory loading. In high speed forward flight, dynamic stall and transonic flow greatly increase the amplitude of vibratory loads. Experiments and computational simulations alike have indicated that a variety of active rotor control devices are capable of reducing vibratory loads. For example, periodic blade twist and flap excitation have been optimized to reduce vibratory loads in various rotors. Airfoil geometry can also be modified in order to increase lift coefficient, delay stall, or weaken transonic effects. To explore the potential benefits of active controls, computational methods are being developed for aeroelastic rotor evaluation, including coupling between computational fluid dynamics (CFD) and computational structural dynamics (CSD) solvers. In many contemporary CFD/CSD coupling methods it is assumed that the airfoil is rigid to reduce the interface by single dimension. Some methods retain the conventional one-dimensional beam model while prescribing an airfoil shape to simulate active chord deformation. However, to simulate the actual response of a compliant airfoil it is necessary to include deformations that originate not only from control devices (such as piezoelectric actuators), but also inertial forces, elastic stresses, and aerodynamic pressures. An accurate representation of the physics requires an interaction with a more complete representation of loads and geometry. A CFD/CSD coupling methodology capable of communicating three-dimensional structural deformations and a distribution of aerodynamic forces over the wetted blade surface has not yet been developed. In this research an interface is created within the Fully Unstructured Navier-Stokes (FUN3D) solver that communicates aerodynamic forces on the blade surface to University of Michigan's Nonlinear Active Beam Solver (UM/NLABS -- referred to as NLABS in this thesis). Interface routines are developed for transmission of force and deflection information to achieve an aeroelastic coupling updated at each time step. The method is validated first by comparing the integrated aerodynamic work at CFD and CSD nodes to verify work conservation across the interface. Second, the method is verified by comparing the sectional blade loads and deflections of a rotor in hover and in forward flight with experimental data. Finally, stability analyses for pitch/plunge flutter and camber flutter are performed with comprehensive CSD/low-order-aerodynamics and tightly coupled CFD/CSD simulations and compared to analytical solutions of Peters' thin airfoil theory to verify proper aeroelastic behavior. The effects of simple harmonic camber actuation are examined and compared to the response predicted by Peters' finite-state (F-S) theory. In anticipation of active rotor experiments inside enclosed facilities, computational simulations are performed to evaluate the capability of CFD for accurately simulating flow inside enclosed volumes. A computational methodology for accurately simulating a rotor inside a test chamber is developed to determine the influence of test facility components and turbulence modeling and performance predictions. A number of factors that influence the physical accuracy of the simulation, such as temporal resolution, grid resolution, and aeroelasticity are also evaluated.
Methods for Improving the User-Computer Interface. Technical Report.
ERIC Educational Resources Information Center
McCann, Patrick H.
This summary of methods for improving the user-computer interface is based on a review of the pertinent literature. Requirements of the personal computer user are identified and contrasted with computer designer perspectives towards the user. The user's psychological needs are described, so that the design of the user-computer interface may be…
Indirect measurement of the solid/liquid interface using the minimization technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, H.; Chun, M.
1985-11-01
The phenomenon of solidification of a flowing fluid in a vertical tube is closely related to the relocation dynamics of molten nuclear fuels in hypothetical core-disruptive accidents of a liquid-metal fast breeder reactor. The knowledge of the transient shape and the position of the liquid/solid interface is of practical importance in analysis of phase change processes. Sparrow and Broadbent directly measured the solid liquid interface via experiments, whereas Viskanta observed the solid/liquid interface motion via a photographic method. In this paper, a new method to predict the transient position of the solid/liquid interface is developed. This method is based onmore » the minimization technique. To use this method one needs the temperature of the wall on which the phase change is to take place. The new technique is useful, in particular, for the case of inward solidification of a flowing fluid in a tube where direct measurement of the solid/liquid interface is not possible, whereas the tube wall temperature measurement is relatively easy.« less
NASA Astrophysics Data System (ADS)
Song, Yeo-Ul; Youn, Sung-Kie; Park, K. C.
2017-10-01
A method for three-dimensional non-matching interface treatment with a virtual gap element is developed. When partitioned structures contain curved interfaces and have different brick meshes, the discretized models have gaps along the interfaces. As these gaps bring unexpected errors, special treatments are required to handle the gaps. In the present work, a virtual gap element is introduced to link the frame and surface domain nodes in the frame work of the mortar method. Since the surface of the hexahedron element is quadrilateral, the gap element is pyramidal. The pyramidal gap element consists of four domain nodes and one frame node. Zero-strain condition in the gap element is utilized for the interpolation of frame nodes in terms of the domain nodes. This approach is taken to satisfy the momentum and energy conservation. The present method is applicable not only to curved interfaces with gaps, but also to flat interfaces in three dimensions. Several numerical examples are given to describe the effectiveness and accuracy of the proposed method.
Dentin bonding performance and interface observation of an MMA-based restorative material.
Shinagawa, Junichi; Inoue, Go; Nikaido, Toru; Ikeda, Masaomi; Sadr, Alireza; Tagami, Junji
2016-07-30
The purpose of this study was to evaluate bonding performance and dentin interface acid resistance using a 4-META/MMA-TBB based restorative material (BF) compared to a conventional 4-META/MMA-TBB resin cement (SB), and the effect of sodium fluoride (NaF) addition to the materials. Dentin surfaces were treated with 10% citric acid-3% ferric chloride (10-3) or 4-META containing self-etching primer (TP), followed by application of BF or SB polymer powders with or without NaF, to evaluate microtensile bond strength (µTBS) in six experimental groups; 10-3/SB, 10-3/BF, TP/SB, TP/BF, TP/SB/NaF and TP/BF/NaF. SEM observation of the resin-dentin interface was performed after acid-base challenge to evaluate interfacial dentin resistance to acid attack. TP/BF showed highest µTBS, while NaF polymers decreased µTBS. TP/BF showed funnel-shaped erosion at the interface, however, NaF polymers improved acid resistance of interface. In conclusion, BF demonstrated high µTBSs and low acid-resistance at the interface. NaF addition enhanced acid resistance but decreased µTBS.
Automation of PCXMC and ImPACT for NASA Astronaut Medical Imaging Dose and Risk Tracking
NASA Technical Reports Server (NTRS)
Bahadori, Amir; Picco, Charles; Flores-McLaughlin, John; Shavers, Mark; Semones, Edward
2011-01-01
To automate astronaut organ and effective dose calculations from occupational X-ray and computed tomography (CT) examinations incorporating PCXMC and ImPACT tools and to estimate the associated lifetime cancer risk per the National Council on Radiation Protection & Measurements (NCRP) using MATLAB(R). Methods: NASA follows guidance from the NCRP on its operational radiation safety program for astronauts. NCRP Report 142 recommends that astronauts be informed of the cancer risks from reported exposures to ionizing radiation from medical imaging. MATLAB(R) code was written to retrieve exam parameters for medical imaging procedures from a NASA database, calculate associated dose and risk, and return results to the database, using the Microsoft .NET Framework. This code interfaces with the PCXMC executable and emulates the ImPACT Excel spreadsheet to calculate organ doses from X-rays and CTs, respectively, eliminating the need to utilize the PCXMC graphical user interface (except for a few special cases) and the ImPACT spreadsheet. Results: Using MATLAB(R) code to interface with PCXMC and replicate ImPACT dose calculation allowed for rapid evaluation of multiple medical imaging exams. The user inputs the exam parameter data into the database and runs the code. Based on the imaging modality and input parameters, the organ doses are calculated. Output files are created for record, and organ doses, effective dose, and cancer risks associated with each exam are written to the database. Annual and post-flight exposure reports, which are used by the flight surgeon to brief the astronaut, are generated from the database. Conclusions: Automating PCXMC and ImPACT for evaluation of NASA astronaut medical imaging radiation procedures allowed for a traceable and rapid method for tracking projected cancer risks associated with over 12,000 exposures. This code will be used to evaluate future medical radiation exposures, and can easily be modified to accommodate changes to the risk calculation procedure.
Zhang, Xiong; Zhao, Yacong; Zhang, Yu; Zhong, Xuefei; Fan, Zhaowen
2018-01-01
The novel human-computer interface (HCI) using bioelectrical signals as input is a valuable tool to improve the lives of people with disabilities. In this paper, surface electromyography (sEMG) signals induced by four classes of wrist movements were acquired from four sites on the lower arm with our designed system. Forty-two features were extracted from the time, frequency and time-frequency domains. Optimal channels were determined from single-channel classification performance rank. The optimal-feature selection was according to a modified entropy criteria (EC) and Fisher discrimination (FD) criteria. The feature selection results were evaluated by four different classifiers, and compared with other conventional feature subsets. In online tests, the wearable system acquired real-time sEMG signals. The selected features and trained classifier model were used to control a telecar through four different paradigms in a designed environment with simple obstacles. Performance was evaluated based on travel time (TT) and recognition rate (RR). The results of hardware evaluation verified the feasibility of our acquisition systems, and ensured signal quality. Single-channel analysis results indicated that the channel located on the extensor carpi ulnaris (ECU) performed best with mean classification accuracy of 97.45% for all movement’s pairs. Channels placed on ECU and the extensor carpi radialis (ECR) were selected according to the accuracy rank. Experimental results showed that the proposed FD method was better than other feature selection methods and single-type features. The combination of FD and random forest (RF) performed best in offline analysis, with 96.77% multi-class RR. Online results illustrated that the state-machine paradigm with a 125 ms window had the highest maneuverability and was closest to real-life control. Subjects could accomplish online sessions by three sEMG-based paradigms, with average times of 46.02, 49.06 and 48.08 s, respectively. These experiments validate the feasibility of proposed real-time wearable HCI system and algorithms, providing a potential assistive device interface for persons with disabilities. PMID:29543737
Measuring the Thermodynamics of the Alloy/Scale Interface
NASA Technical Reports Server (NTRS)
Copland, Evan
2004-01-01
A method is proposed for the direct measurement of the thermodynamic properties of the alloy and oxide compound at the alloy/scale interface observed during steady-state oxidation. The thermodynamic properties of the alloy/scale interface define the driving force for solid-state transport in the alloy and oxide compound. Accurate knowledge of thermodynamic properties of the interface will advance our understanding of oxidation behavior. The method is based on the concept of local equilibrium and assumes that an alloy+scale equilibrium very closely approximates the alloy/scale interface observed during steady-state oxidation. The thermodynamics activities of this alloy+scale equilibrium are measured directly by Knudsen effusion-cell mass spectrometer (KEMS) using the vapor pressure technique. The theory and some practical considerations of this method are discussed in terms of beta-NiAl oxidation.
Understanding biomaterial-tissue interface quality: combined in vitro evaluation
Gasik, Michael
2017-01-01
Abstract One of the greatest challenges in the development of new medical products and devices remains in providing maximal patient safety, efficacy and suitability for the purpose. A ‘good quality’ of the tissue-implant interface is one of the most critical factors for the success of the implant integration. In this paper this challenge is being discussed from the point of view of basic stimuli combination to experimental testing. The focus is in particular on bacterial effects on tissue-implant interaction (for different materials). The demonstration of the experimental evaluation of the tissue-implant interface is for dental abutment with mucosal contact. This shows that testing of the interface quality could be the most relevant in controlled conditions, which mimic as possible the clinical applications, but consider variables being under the control of the evaluator. PMID:28970865
Wearable computer for mobile augmented-reality-based controlling of an intelligent robot
NASA Astrophysics Data System (ADS)
Turunen, Tuukka; Roening, Juha; Ahola, Sami; Pyssysalo, Tino
2000-10-01
An intelligent robot can be utilized to perform tasks that are either hazardous or unpleasant for humans. Such tasks include working in disaster areas or conditions that are, for example, too hot. An intelligent robot can work on its own to some extent, but in some cases the aid of humans will be needed. This requires means for controlling the robot from somewhere else, i.e. teleoperation. Mobile augmented reality can be utilized as a user interface to the environment, as it enhances the user's perception of the situation compared to other interfacing methods and allows the user to perform other tasks while controlling the intelligent robot. Augmented reality is a method that combines virtual objects into the user's perception of the real world. As computer technology evolves, it is possible to build very small devices that have sufficient capabilities for augmented reality applications. We have evaluated the existing wearable computers and mobile augmented reality systems to build a prototype of a future mobile terminal- the CyPhone. A wearable computer with sufficient system resources for applications, wireless communication media with sufficient throughput and enough interfaces for peripherals has been built at the University of Oulu. It is self-sustained in energy, with enough operating time for the applications to be useful, and uses accurate positioning systems.
User interface using a 3D model for video surveillance
NASA Astrophysics Data System (ADS)
Hata, Toshihiko; Boh, Satoru; Tsukada, Akihiro; Ozaki, Minoru
1998-02-01
These days fewer people, who must carry out their tasks quickly and precisely, are required in industrial surveillance and monitoring applications such as plant control or building security. Utilizing multimedia technology is a good approach to meet this need, and we previously developed Media Controller, which is designed for the applications and provides realtime recording and retrieval of digital video data in a distributed environment. In this paper, we propose a user interface for such a distributed video surveillance system in which 3D models of buildings and facilities are connected to the surveillance video. A novel method of synchronizing camera field data with each frame of a video stream is considered. This method records and reads the camera field data similarity to the video data and transmits it synchronously with the video stream. This enables the user interface to have such useful functions as comprehending the camera field immediately and providing clues when visibility is poor, for not only live video but also playback video. We have also implemented and evaluated the display function which makes surveillance video and 3D model work together using Media Controller with Java and Virtual Reality Modeling Language employed for multi-purpose and intranet use of 3D model.
EDITORIAL: Focus on the neural interface Focus on the neural interface
NASA Astrophysics Data System (ADS)
Durand, Dominique M.
2009-10-01
The possibility of an effective connection between neural tissue and computers has inspired scientists and engineers to develop new ways of controlling and obtaining information from the nervous system. These applications range from `brain hacking' to neural control of artificial limbs with brain signals. Notwithstanding the significant advances in neural prosthetics in the last few decades and the success of some stimulation devices such as cochlear prosthesis, neurotechnology remains below its potential for restoring neural function in patients with nervous system disorders. One of the reasons for this limited impact can be found at the neural interface and close attention to the integration between electrodes and tissue should improve the possibility of successful outcomes. The neural interfaces research community consists of investigators working in areas such as deep brain stimulation, functional neuromuscular/electrical stimulation, auditory prostheses, cortical prostheses, neuromodulation, microelectrode array technology, brain-computer/machine interfaces. Following the success of previous neuroprostheses and neural interfaces workshops, funding (from NIH) was obtained to establish a biennial conference in the area of neural interfaces. The first Neural Interfaces Conference took place in Cleveland, OH in 2008 and several topics from this conference have been selected for publication in this special section of the Journal of Neural Engineering. Three `perspectives' review the areas of neural regeneration (Corredor and Goldberg), cochlear implants (O'Leary et al) and neural prostheses (Anderson). Seven articles focus on various aspects of neural interfacing. One of the most popular of these areas is the field of brain-computer interfaces. Fraser et al, report on a method to generate robust control with simple signal processing algorithms of signals obtained with electrodes implanted in the brain. One problem with implanted electrode arrays, however, is that they can fail to record reliably neural signals for long periods of time. McConnell et al show that by measuring the impedance of the tissue, one can evaluate the extent of the tissue response to the presence of the electrode. Another problem with the neural interface is the mismatch of the mechanical properties between electrode and tissue. Basinger et al use finite element modeling to analyze this mismatch in retinal prostheses and guide the design of new implantable devices. Electrical stimulation has been the method of choice to activate externally the nervous system. However, Zhang et al show that a novel dual hybrid device integrating electrical and optical stimulation can provide an effective interface for simultaneous recording and stimulation. By interfacing an EMG recording system and a movement detection system, Johnson and Fuglevand develop a model capable of predicting muscle activity during movement that could be important for the development of motor prostheses. Sensory restoration is another unsolved problem in neural prostheses. By developing a novel interface between the dorsal root ganglia and electrodes arrays, Gaunt et al show that it is possible to recruit afferent fibers for sensory substitution. Finally, by interfacing directly with muscles, Jung and colleagues show that stimulation of muscles involved in locomotion following spinal cord damage in rats can provide an effective treatment modality for incomplete spinal cord injury. This series of articles clearly shows that the interface is indeed one of the keys to successful therapeutic neural devices. The next Neural Interfaces Conference will take place in Los Angeles, CA in June 2010 and one can expect to see new developments in neural engineering obtained by focusing on the neural interface.
Electronic structure of metals and semiconductors: bulk, surface, and interface properties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Louie, S.G.S.
1976-09-01
A theoretical study of the electronic structure of various metals and semiconductors is presented with the emphasis on understanding the properties of these materials when they are subjected to extreme conditions and in various different configurations. Among the bulk systems studied, the properties of cesium under high pressure are discussed in terms of the electronic structure calculated at various cell volumes using the pseudopotential method. Local fields or umklapp processes in semiconductors are studied within the random phase approximation (RPA). Specifically the dielectric response matrix epsilon/sub GG'/ (q = 0,omega) is evaluated numerically to determine the effects of local-field correctionsmore » in the optical spectrum of Si. Also, some comments on the excitonic mechanism of superconductivity are presented and the role of local fields is discussed. The pseudo-potential method is next extended to calculate the electronic structure of a transition metal Nb. The calculation is performed self-consistently with the use of a non-local ionic potential determined from atomic spectra. Finally the theory of the superconducting transition temperature T/sub c/ is discussed in the strong-coupling formulation of the BCS theory. The Eliashberg equations in the Matsubara representation are solved analytically and a general T/sub c/ equation is obtained. A new method is developed using pseudopotentials in a self-consistent manner to describe non-periodic systems. The method is applicable to localized configurations such as molecules, surfaces, impurities, vacancies, finite chains of atoms, adsorbates, and solid interfaces. Specific applications to surfaces, metal-semiconductor interfaces and vacancies are presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Yong; Chu, Yuchuan; He, Xiaoming
This paper proposes a domain decomposition method for the coupled stationary Navier-Stokes and Darcy equations with the Beavers-Joseph-Saffman interface condition in order to improve the efficiency of the finite element method. The physical interface conditions are directly utilized to construct the boundary conditions on the interface and then decouple the Navier-Stokes and Darcy equations. Newton iteration will be used to deal with the nonlinear systems. Numerical results are presented to illustrate the features of the proposed method.
Usability study of clinical exome analysis software: top lessons learned and recommendations.
Shyr, Casper; Kushniruk, Andre; Wasserman, Wyeth W
2014-10-01
New DNA sequencing technologies have revolutionized the search for genetic disruptions. Targeted sequencing of all protein coding regions of the genome, called exome analysis, is actively used in research-oriented genetics clinics, with the transition to exomes as a standard procedure underway. This transition is challenging; identification of potentially causal mutation(s) amongst ∼10(6) variants requires specialized computation in combination with expert assessment. This study analyzes the usability of user interfaces for clinical exome analysis software. There are two study objectives: (1) To ascertain the key features of successful user interfaces for clinical exome analysis software based on the perspective of expert clinical geneticists, (2) To assess user-system interactions in order to reveal strengths and weaknesses of existing software, inform future design, and accelerate the clinical uptake of exome analysis. Surveys, interviews, and cognitive task analysis were performed for the assessment of two next-generation exome sequence analysis software packages. The subjects included ten clinical geneticists who interacted with the software packages using the "think aloud" method. Subjects' interactions with the software were recorded in their clinical office within an urban research and teaching hospital. All major user interface events (from the user interactions with the packages) were time-stamped and annotated with coding categories to identify usability issues in order to characterize desired features and deficiencies in the user experience. We detected 193 usability issues, the majority of which concern interface layout and navigation, and the resolution of reports. Our study highlights gaps in specific software features typical within exome analysis. The clinicians perform best when the flow of the system is structured into well-defined yet customizable layers for incorporation within the clinical workflow. The results highlight opportunities to dramatically accelerate clinician analysis and interpretation of patient genomic data. We present the first application of usability methods to evaluate software interfaces in the context of exome analysis. Our results highlight how the study of user responses can lead to identification of usability issues and challenges and reveal software reengineering opportunities for improving clinical next-generation sequencing analysis. While the evaluation focused on two distinctive software tools, the results are general and should inform active and future software development for genome analysis software. As large-scale genome analysis becomes increasingly common in healthcare, it is critical that efficient and effective software interfaces are provided to accelerate clinical adoption of the technology. Implications for improved design of such applications are discussed. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Test Method Designed to Evaluate Cylinder Liner-Piston Ring Coatings for Advanced Heat Engines
NASA Technical Reports Server (NTRS)
Radil, Kevin C.
1997-01-01
Research on advanced heat engine concepts, such as the low-heat-rejection engine, have shown the potential for increased thermal efficiency, reduced emissions, lighter weight, simpler design, and longer life in comparison to current diesel engine designs. A major obstacle in the development of a functional advanced heat engine is overcoming the problems caused by the high combustion temperatures at the piston ring/cylinder liner interface, specifically at top ring reversal (TRR). Therefore, advanced cylinder liner and piston ring materials are needed that can survive under these extreme conditions. To address this need, researchers at the NASA Lewis Research Center have designed a tribological test method to help evaluate candidate piston ring and cylinder liner materials for advanced diesel engines.
Assessing the Usability of Six Data Entry Mobile Interfaces for Caregivers: A Randomized Trial
Haller, Guy; Sarrey, Evelyne; Walesa, Magali; Wipfli, Rolf; Lovis, Christian
2015-01-01
Background There is an increased demand in hospitals for tools, such as dedicated mobile device apps, that enable the recording of clinical information in an electronic format at the patient’s bedside. Although the human-machine interface design on mobile devices strongly influences the accuracy and effectiveness of data recording, there is still a lack of evidence as to which interface design offers the best guarantee for ease of use and quality of recording. Therefore, interfaces need to be assessed both for usability and reliability because recording errors can seriously impact the overall level of quality of the data and affect the care provided. Objective In this randomized crossover trial, we formally compared 6 handheld device interfaces for both speed of data entry and accuracy of recorded information. Three types of numerical data commonly recorded at the patient’s bedside were used to evaluate the interfaces. Methods In total, 150 health care professionals from the University Hospitals of Geneva volunteered to record a series of randomly generated data on each of the 6 interfaces provided on a smartphone. The interfaces were presented in a randomized order as part of fully automated data entry scenarios. During the data entry process, accuracy and effectiveness were automatically recorded by the software. Results Various types of errors occurred, which ranged from 0.7% for the most reliable design to 18.5% for the least reliable one. The length of time needed for data recording ranged from 2.81 sec to 14.68 sec, depending on the interface. The numeric keyboard interface delivered the best performance for pulse data entry with a mean time of 3.08 sec (SD 0.06) and an accuracy of 99.3%. Conclusions Our study highlights the critical impact the choice of an interface can have on the quality of recorded data. Selecting an interface should be driven less by the needs of specific end-user groups or the necessity to facilitate the developer’s task (eg, by opting for default solutions provided by commercial platforms) than by the level of speed and accuracy an interface can provide for recording information. An important effort must be made to properly validate mobile device interfaces intended for use in the clinical setting. In this regard, our study identified the numeric keyboard, among the proposed designs, as the most accurate interface for entering specific numerical values. This is an important step toward providing clearer guidelines on which interface to choose for the appropriate use of handheld device interfaces in the health care setting. PMID:27025648
Numerical solution of the Hele-Shaw equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitaker, N.
1987-04-01
An algorithm is presented for approximating the motion of the interface between two immiscible fluids in a Hele-Shaw cell. The interface is represented by a set of volume fractions. We use the Simple Line Interface Calculation method along with the method of fractional steps to transport the interface. The equation of continuity leads to a Poisson equation for the pressure. The Poisson equation is discretized. Near the interface where the velocity field is discontinuous, the discretization is based on a weak formulation of the continuity equation. Interpolation is used on each side of the interface to increase the accuracy ofmore » the algorithm. The weak formulation as well as the interpolation are based on the computed volume fractions. This treatment of the interface is new. The discretized equations are solved by a modified conjugate gradient method. Surface tension is included and the curvature is computed through the use of osculating circles. For perturbations of small amplitude, a surprisingly good agreement is found between the numerical results and linearized perturbation theory. Numerical results are presented for the finite amplitude growth of unstable fingers. 62 refs., 13 figs.« less
HomPPI: a class of sequence homology based protein-protein interface prediction methods
2011-01-01
Background Although homology-based methods are among the most widely used methods for predicting the structure and function of proteins, the question as to whether interface sequence conservation can be effectively exploited in predicting protein-protein interfaces has been a subject of debate. Results We studied more than 300,000 pair-wise alignments of protein sequences from structurally characterized protein complexes, including both obligate and transient complexes. We identified sequence similarity criteria required for accurate homology-based inference of interface residues in a query protein sequence. Based on these analyses, we developed HomPPI, a class of sequence homology-based methods for predicting protein-protein interface residues. We present two variants of HomPPI: (i) NPS-HomPPI (Non partner-specific HomPPI), which can be used to predict interface residues of a query protein in the absence of knowledge of the interaction partner; and (ii) PS-HomPPI (Partner-specific HomPPI), which can be used to predict the interface residues of a query protein with a specific target protein. Our experiments on a benchmark dataset of obligate homodimeric complexes show that NPS-HomPPI can reliably predict protein-protein interface residues in a given protein, with an average correlation coefficient (CC) of 0.76, sensitivity of 0.83, and specificity of 0.78, when sequence homologs of the query protein can be reliably identified. NPS-HomPPI also reliably predicts the interface residues of intrinsically disordered proteins. Our experiments suggest that NPS-HomPPI is competitive with several state-of-the-art interface prediction servers including those that exploit the structure of the query proteins. The partner-specific classifier, PS-HomPPI can, on a large dataset of transient complexes, predict the interface residues of a query protein with a specific target, with a CC of 0.65, sensitivity of 0.69, and specificity of 0.70, when homologs of both the query and the target can be reliably identified. The HomPPI web server is available at http://homppi.cs.iastate.edu/. Conclusions Sequence homology-based methods offer a class of computationally efficient and reliable approaches for predicting the protein-protein interface residues that participate in either obligate or transient interactions. For query proteins involved in transient interactions, the reliability of interface residue prediction can be improved by exploiting knowledge of putative interaction partners. PMID:21682895
Walia, Rasna R; Caragea, Cornelia; Lewis, Benjamin A; Towfic, Fadi; Terribilini, Michael; El-Manzalawy, Yasser; Dobbs, Drena; Honavar, Vasant
2012-05-10
RNA molecules play diverse functional and structural roles in cells. They function as messengers for transferring genetic information from DNA to proteins, as the primary genetic material in many viruses, as catalysts (ribozymes) important for protein synthesis and RNA processing, and as essential and ubiquitous regulators of gene expression in living organisms. Many of these functions depend on precisely orchestrated interactions between RNA molecules and specific proteins in cells. Understanding the molecular mechanisms by which proteins recognize and bind RNA is essential for comprehending the functional implications of these interactions, but the recognition 'code' that mediates interactions between proteins and RNA is not yet understood. Success in deciphering this code would dramatically impact the development of new therapeutic strategies for intervening in devastating diseases such as AIDS and cancer. Because of the high cost of experimental determination of protein-RNA interfaces, there is an increasing reliance on statistical machine learning methods for training predictors of RNA-binding residues in proteins. However, because of differences in the choice of datasets, performance measures, and data representations used, it has been difficult to obtain an accurate assessment of the current state of the art in protein-RNA interface prediction. We provide a review of published approaches for predicting RNA-binding residues in proteins and a systematic comparison and critical assessment of protein-RNA interface residue predictors trained using these approaches on three carefully curated non-redundant datasets. We directly compare two widely used machine learning algorithms (Naïve Bayes (NB) and Support Vector Machine (SVM)) using three different data representations in which features are encoded using either sequence- or structure-based windows. Our results show that (i) Sequence-based classifiers that use a position-specific scoring matrix (PSSM)-based representation (PSSMSeq) outperform those that use an amino acid identity based representation (IDSeq) or a smoothed PSSM (SmoPSSMSeq); (ii) Structure-based classifiers that use smoothed PSSM representation (SmoPSSMStr) outperform those that use PSSM (PSSMStr) as well as sequence identity based representation (IDStr). PSSMSeq classifiers, when tested on an independent test set of 44 proteins, achieve performance that is comparable to that of three state-of-the-art structure-based predictors (including those that exploit geometric features) in terms of Matthews Correlation Coefficient (MCC), although the structure-based methods achieve substantially higher Specificity (albeit at the expense of Sensitivity) compared to sequence-based methods. We also find that the expected performance of the classifiers on a residue level can be markedly different from that on a protein level. Our experiments show that the classifiers trained on three different non-redundant protein-RNA interface datasets achieve comparable cross-validation performance. However, we find that the results are significantly affected by differences in the distance threshold used to define interface residues. Our results demonstrate that protein-RNA interface residue predictors that use a PSSM-based encoding of sequence windows outperform classifiers that use other encodings of sequence windows. While structure-based methods that exploit geometric features can yield significant increases in the Specificity of protein-RNA interface residue predictions, such increases are offset by decreases in Sensitivity. These results underscore the importance of comparing alternative methods using rigorous statistical procedures, multiple performance measures, and datasets that are constructed based on several alternative definitions of interface residues and redundancy cutoffs as well as including evaluations on independent test sets into the comparisons.
User needs analysis and usability assessment of DataMed - a biomedical data discovery index.
Dixit, Ram; Rogith, Deevakar; Narayana, Vidya; Salimi, Mandana; Gururaj, Anupama; Ohno-Machado, Lucila; Xu, Hua; Johnson, Todd R
2017-11-30
To present user needs and usability evaluations of DataMed, a Data Discovery Index (DDI) that allows searching for biomedical data from multiple sources. We conducted 2 phases of user studies. Phase 1 was a user needs analysis conducted before the development of DataMed, consisting of interviews with researchers. Phase 2 involved iterative usability evaluations of DataMed prototypes. We analyzed data qualitatively to document researchers' information and user interface needs. Biomedical researchers' information needs in data discovery are complex, multidimensional, and shaped by their context, domain knowledge, and technical experience. User needs analyses validate the need for a DDI, while usability evaluations of DataMed show that even though aggregating metadata into a common search engine and applying traditional information retrieval tools are promising first steps, there remain challenges for DataMed due to incomplete metadata and the complexity of data discovery. Biomedical data poses distinct problems for search when compared to websites or publications. Making data available is not enough to facilitate biomedical data discovery: new retrieval techniques and user interfaces are necessary for dataset exploration. Consistent, complete, and high-quality metadata are vital to enable this process. While available data and researchers' information needs are complex and heterogeneous, a successful DDI must meet those needs and fit into the processes of biomedical researchers. Research directions include formalizing researchers' information needs, standardizing overviews of data to facilitate relevance judgments, implementing user interfaces for concept-based searching, and developing evaluation methods for open-ended discovery systems such as DDIs. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Kalawsky, R S
1999-02-01
A special questionnaire (VRUSE) has been designed to measure the usability of a VR system according to the attitude and perception of its users. Important aspects of VR systems were carefully derived to produce key usability factors for the questionnaire. Unlike questionnaires designed for generic interfaces VRUSE is specifically designed to cater for evaluating virtual environments, being a diagnostic tool providing a wealth of information about a user's viewpoint of the interface. VRUSE can be used to great effect with other evaluation techniques to pinpoint problematical areas of a VR interface. Other applications include bench-marking of competitor VR systems.
Decoder calibration with ultra small current sample set for intracortical brain-machine interface
NASA Astrophysics Data System (ADS)
Zhang, Peng; Ma, Xuan; Chen, Luyao; Zhou, Jin; Wang, Changyong; Li, Wei; He, Jiping
2018-04-01
Objective. Intracortical brain-machine interfaces (iBMIs) aim to restore efficient communication and movement ability for paralyzed patients. However, frequent recalibration is required for consistency and reliability, and every recalibration will require relatively large most current sample set. The aim in this study is to develop an effective decoder calibration method that can achieve good performance while minimizing recalibration time. Approach. Two rhesus macaques implanted with intracortical microelectrode arrays were trained separately on movement and sensory paradigm. Neural signals were recorded to decode reaching positions or grasping postures. A novel principal component analysis-based domain adaptation (PDA) method was proposed to recalibrate the decoder with only ultra small current sample set by taking advantage of large historical data, and the decoding performance was compared with other three calibration methods for evaluation. Main results. The PDA method closed the gap between historical and current data effectively, and made it possible to take advantage of large historical data for decoder recalibration in current data decoding. Using only ultra small current sample set (five trials of each category), the decoder calibrated using the PDA method could achieve much better and more robust performance in all sessions than using other three calibration methods in both monkeys. Significance. (1) By this study, transfer learning theory was brought into iBMIs decoder calibration for the first time. (2) Different from most transfer learning studies, the target data in this study were ultra small sample set and were transferred to the source data. (3) By taking advantage of historical data, the PDA method was demonstrated to be effective in reducing recalibration time for both movement paradigm and sensory paradigm, indicating a viable generalization. By reducing the demand for large current training data, this new method may facilitate the application of intracortical brain-machine interfaces in clinical practice.
NASA Astrophysics Data System (ADS)
Ge, Liang; Sotiropoulos, Fotis
2007-08-01
A novel numerical method is developed that integrates boundary-conforming grids with a sharp interface, immersed boundary methodology. The method is intended for simulating internal flows containing complex, moving immersed boundaries such as those encountered in several cardiovascular applications. The background domain (e.g. the empty aorta) is discretized efficiently with a curvilinear boundary-fitted mesh while the complex moving immersed boundary (say a prosthetic heart valve) is treated with the sharp-interface, hybrid Cartesian/immersed-boundary approach of Gilmanov and Sotiropoulos [A. Gilmanov, F. Sotiropoulos, A hybrid cartesian/immersed boundary method for simulating flows with 3d, geometrically complex, moving bodies, Journal of Computational Physics 207 (2005) 457-492.]. To facilitate the implementation of this novel modeling paradigm in complex flow simulations, an accurate and efficient numerical method is developed for solving the unsteady, incompressible Navier-Stokes equations in generalized curvilinear coordinates. The method employs a novel, fully-curvilinear staggered grid discretization approach, which does not require either the explicit evaluation of the Christoffel symbols or the discretization of all three momentum equations at cell interfaces as done in previous formulations. The equations are integrated in time using an efficient, second-order accurate fractional step methodology coupled with a Jacobian-free, Newton-Krylov solver for the momentum equations and a GMRES solver enhanced with multigrid as preconditioner for the Poisson equation. Several numerical experiments are carried out on fine computational meshes to demonstrate the accuracy and efficiency of the proposed method for standard benchmark problems as well as for unsteady, pulsatile flow through a curved, pipe bend. To demonstrate the ability of the method to simulate flows with complex, moving immersed boundaries we apply it to calculate pulsatile, physiological flow through a mechanical, bileaflet heart valve mounted in a model straight aorta with an anatomical-like triple sinus.
LOSITAN: a workbench to detect molecular adaptation based on a Fst-outlier method.
Antao, Tiago; Lopes, Ana; Lopes, Ricardo J; Beja-Pereira, Albano; Luikart, Gordon
2008-07-28
Testing for selection is becoming one of the most important steps in the analysis of multilocus population genetics data sets. Existing applications are difficult to use, leaving many non-trivial, error-prone tasks to the user. Here we present LOSITAN, a selection detection workbench based on a well evaluated Fst-outlier detection method. LOSITAN greatly facilitates correct approximation of model parameters (e.g., genome-wide average, neutral Fst), provides data import and export functions, iterative contour smoothing and generation of graphics in a easy to use graphical user interface. LOSITAN is able to use modern multi-core processor architectures by locally parallelizing fdist, reducing computation time by half in current dual core machines and with almost linear performance gains in machines with more cores. LOSITAN makes selection detection feasible to a much wider range of users, even for large population genomic datasets, by both providing an easy to use interface and essential functionality to complete the whole selection detection process.
Optical coherence tomography and confocal microscopy investigations of dental prostheses
NASA Astrophysics Data System (ADS)
Negrutiu, Meda L.; Sinescu, Cosmin; Hughes, Michael; Bradu, Adrian; Rominu, Mihai; Todea, Carmen; Dobre, George; Podoleanu, Adrian
2008-09-01
Dental prostheses are very complex systems, heterogenous in structure, made up from various materials, with different physical properties. An essential question mark is on the physical, chemical and mechanical compatibility between these materials. They have to satisfy high stress requirements as well as esthetic challenges. The masticatory stress may induce fractures of the prostheses, which may be triggered by initial materials defects or by alterations of the technological process. The failures of dental prostheses lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. The purpose of this study is to evaluate the capability of en-face optical coherence tomography as a possible non-invasive high resolution method in supplying the necessary information on the material defects of dental prostheses and microleakage at prosthetic interfaces. C-scan and B-scan OCT images as well as confocal images are acquired from a large range of samples. Gaps between the dental interfaces and material defects are clearly exposed. We conclude that OCT can successfully be used as a noninvasive analysis method.
The alteration of lipid bilayer dynamics by phloretin and 6-ketocholestanol.
Przybylo, M; Procek, J; Hof, M; Langner, M
2014-02-01
Lipid bilayer properties are quantified with a variety of arbitrary selected parameters such as molecular packing and dynamics, electrostatic potentials or permeability. In the paper we determined the effect of phloretin and 6-ketocholestanol (dipole potential modifying agents) on the membrane hydration and efficiency of the trans-membrane water flow. The dynamics of water molecules within the lipid bilayer interface was evaluated using solvent relaxation method, whereas the osmotically induced trans-membrane water flux was estimated with the stopped-flow method using the liposome shrinkage kinetics. The presence of phloretin or 6-ketocholestanol resulted in a change of both, the interfacial hydration level and osmotically driven water fluxes. Specifically, the presence of 6-ketocholestanol reduced the amount and mobility of water in the membrane interface. It also slows the osmotically induced water flow. The interfacial hydration change caused by phloretin was much smaller and the effect on osmotically induced water flow was opposite to that of 6-ketocholestanol. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Batisse, Nicolas; Raymundo-Piñero, Encarnación
2017-11-29
A more detailed understanding of the electrode/electrolyte interface degradation during the charging cycle in supercapacitors is of great interest for exploring the voltage stability range and therefore the extractable energy. The evaluation of the gas evolution during the charging, discharging, and aging processes is a powerful tool toward determining the stability and energy capacity of supercapacitors. Here, we attempt to fit the gas analysis resolution to the time response of a low-gas-generation power device by adopting a modified pulsed electrochemical mass spectrometry (PEMS) method. The pertinence of the method is shown using a symmetric carbon/carbon supercapacitor operating in different aqueous electrolytes. The differences observed in the gas levels and compositions as a function of the cell voltage correlate to the evolution of the physicochemical characteristics of the carbon electrodes and to the electrochemical performance, giving a complete picture of the processes taking place at the electrode/electrolyte interface.
JPRS Report Science & Technology USSR: Chemistry
1991-08-29
EXPLOSIVES Cryostatic Problems at Temperatures Below 2 K. Part 2. Analysis of Principal Refrigerator Designs //. F. Kuzmenko; KHIMICHESKOYEINEFTYANOYE...VOLOKNA, No 1, Jan 91] 24 Eperimental Method for Evaluating Quality of Core-Shell Interface in Polymeric Light Conductors [M. A. Maryukov...No 3, Mar 91 pp 178-179 [Article by Yu. S. Ivchenko] UDC 66.023.002.237:66.063.8 [Abstract] An attempt was made to design a universal apparatus
New Methods for Representing and Interacting with Qualitative Geographic Information
2012-10-31
Penn State University Report on Component 3: SensePlace2 Evaluation Anthony C. Robinson, Scott Pezanowski, Alexander Savelyev , and Alan M...NUMBER 6. AUTHOR(S) Alexander Savelyev , Scott Pezanowski, Anthony C. Robinson, and Alan M. MacEachren 5d. PROJECT NUMBER 5e. TASK NUMBER 5f...2012. SensePlace2 Interface Mini-Guide Alan M. MacEachren, Alexander Savelyev , and Scott Pezanowski GeoVISTA Center, Pennsylvania State University
Effect of temperature gradient on the optical quality of mercurous chloride crystals
NASA Technical Reports Server (NTRS)
Singh, N. B.; Davies, D. K.; Gottlieb, M.; Henningsen, T.; Mazelsky, R.
1989-01-01
Single crystals of mercurous chloride were grown at temperature gradients of 8, 11 and 17 K/cm by the physical vapor transport method. The optical quality of these crystals was evaluated by measuring bulk scattering and inhomogeneity of refractive index by birefringence interferometry. It was observed that a high temperature gradient at the solid-vapor interface induced thermal stresses and crystals showed higher scattering and irregular fringes.
A block-based algorithm for the solution of compressible flows in rotor-stator combinations
NASA Technical Reports Server (NTRS)
Akay, H. U.; Ecer, A.; Beskok, A.
1990-01-01
A block-based solution algorithm is developed for the solution of compressible flows in rotor-stator combinations. The method allows concurrent solution of multiple solution blocks in parallel machines. It also allows a time averaged interaction at the stator-rotor interfaces. Numerical results are presented to illustrate the performance of the algorithm. The effect of the interaction between the stator and rotor is evaluated.
An overview of the evaluation plan for PC/MISI: PC-based Multiple Information System Interface
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Lim, Bee Lee; Hall, Philip P.
1985-01-01
An initial evaluation plan for the personal computer multiple information system interface (PC/MISI) project is discussed. The document is intend to be used as a blueprint for the evaluation of this system. Each objective of the design project is discussed along with the evaluation parameters and methodology to be used in the evaluation of the implementation's achievement of those objectives. The potential of the system for research activities related to more general aspects of information retrieval is also discussed.
An Impulse Based Substructuring approach for impact analysis and load case simulations
NASA Astrophysics Data System (ADS)
Rixen, Daniel J.; van der Valk, Paul L. C.
2013-12-01
In the present paper we outline the basic theory of assembling substructures for which the dynamics are described as Impulse Response Functions. The assembly procedure computes the time response of a system by evaluating per substructure the convolution product between the Impulse Response Functions and the applied forces, including the interface forces that are computed to satisfy the interface compatibility. We call this approach the Impulse Based Substructuring method since it transposes to the time domain the Frequency Based Substructuring approach. In the Impulse Based Substructuring technique the Impulse Response Functions of the substructures can be gathered either from experimental tests using a hammer impact or from time-integration of numerical submodels. In this paper the implementation of the method is outlined for the case when the impulse responses of the substructures are computed numerically. A simple bar example is shown in order to illustrate the concept. The Impulse Based Substructuring allows fast evaluation of impact response of a structure when the impulse response of its components is known. It can thus be used to efficiently optimize designs of consumer products by including impact behavior at the early stage of the design, but also for performing substructured simulations of complex structures such as offshore wind turbines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Chia-Chi; Yu, Chih-peng; Wu, Jiunn-Hong
2014-02-18
Cracks and honeycombs are often found inside reinforced concrete (RC) structure caused by excessive external force, or improper casting of concrete. The repairing method usually involves epoxy injection. The impact-echo method, which is a sensitive for detecting of the interior voids, may not be applicable to assess the integrity of the repaired member as both air and epoxy are less in acoustic impedances. In this study, the repaired RC structure was evaluated by the simulated transfer function of the IE displacement waveform where the R-wave displacement waveform is used as a base of a simulated force-time function. The effect ofmore » different thickness of the epoxy layer to the amplitude corresponding to the interface is studied by testing on specimen containing repaired naturally delaminated cracks with crack widths about 1 mm, 3 mm and 5 mm. The impact-echo responses were compared with the drilling cores at the test positions. The results showed the cracks were not fully filled with epoxy when the peak amplitude corresponding to the interface dropped less than 20%. The peak corresponding to the thicker epoxy layer tends to be larger in amplitude. A field study was also performed on a column damaged by earthquake before and after repairing.« less
NASA Astrophysics Data System (ADS)
Todoran, R.; Todoran, D.; Anitas, E. M.; Szakács, Zs
2016-08-01
We propose reflectance measurements as a method for the evaluation of the kinetics of adsorption processes, to compute the diffusion times of the adsorption products at the thin layers formed at the sphalerite natural mineral-potassium ethyl xanthate solution interface. The method is based on the intensity measurement of the reflected monochromatic radiation obtained from the mineral-xanthate thin layer as a function of time. These determinations were made at the thin layer formed between the sphalerite or activated sphalerite natural minerals with potassium ethyl xanthate, for different solutions concentrations and pH values at constant temperature. Diffusion times of desorbed molecular species into the liquid bring important information about the global kinetics of the ions in this phase during adsorption processes at interfaces. Analysing the time dependence of this parameter one concluded on the diffusion properties of the xanthate molecule in the solution depending on its concentration and pH, knowing that at the initial time these molecules had a uniform spread. This method enabled us to determine that, in time interval of approximately 35 minutes to achieve dynamic equilibrium in the formation of the interface layer, one had three different kinetic behaviours of our systems. In the first 5-8 min one had highly adsorbent character, the state of equilibrium is followed by low adsorbent properties. Gaining information on the adsorption kinetics in the case of xanthate on mineral surface leads to the optimization of the industrial froth flotation process.
Leroy, Frédéric; Müller-Plathe, Florian
2015-08-04
We introduce a methodology, referred to as the dry-surface method, to calculate the work of adhesion of heterogeneous solid-liquid interfaces by molecular simulation. This method employs a straightforward thermodynamic integration approach to calculate the work of adhesion as the reversible work to turn off the attractive part of the actual solid-liquid interaction potential. It is formulated in such a way that it may be used either to evaluate the ability of force fields to reproduce reference values of the work of adhesion or to optimize force-field parameters with reference values of the work of adhesion as target quantities. The methodology is tested in the case of water on a generic model of nonpolar substrates with the structure of gold. It is validated through a quantitative comparison to phantom-wall calculations and against a previous characterization of the thermodynamics of the gold-water interface. It is found that the work of adhesion of water on nonpolar substrates is a nonlinear function of the microscopic solid-liquid interaction energy parameter. We also comment on the ability of mean-field approaches to predict the work of adhesion of water on nonpolar substrates. In addition, we discuss in detail the information on the solid-liquid interfacial thermodynamics delivered by the phantom-wall approach. We show that phantom-wall calculations yield the solid-liquid interfacial tension relative to the solid surface tension rather than the absolute solid-liquid interfacial tension as previously believed.
First-Principles Approach to Energy Level Alignment at Aqueous Semiconductor Interfaces
NASA Astrophysics Data System (ADS)
Hybertsen, Mark
2015-03-01
We have developed a first principles method to calculate the energy level alignment between semiconductor band edges and reference energy levels at aqueous interfaces. This alignment is fundamental to understand the electrochemical characteristics of any semiconductor electrode in general and the potential for photocatalytic activity in particular. For example, in the search for new photo-catalytic materials, viable candidates must demonstrate both efficient absorption of the solar spectrum and an appropriate alignment of the band edge levels in the semiconductor to the redox levels for the target reactions. In our approach, the interface-specific contribution to the electrostatic step across the interface is evaluated using density functional theory (DFT) based molecular dynamics to sample the physical interface structure and the corresponding change in the electrostatic potential at the interface. The reference electronic levels in the semiconductor and in the water are calculated using the GW approach, which naturally corrects for errors inherent in the use of Kohn-Sham energy eigenvalues to approximate the electronic excitation energies in each material. Taken together, our calculations provide the alignment of the semiconductor valence band edge to the centroid of the highest occupied 1b1 level in water. The known relationship of the 1b1 level to the normal hydrogen electrode completes the connection to electrochemical levels. We discuss specific results for GaN, ZnO, and TiO2. The effect of interface structural motifs, such as different degrees of water dissociation, and of dynamical characteristics, will be presented together with available experimental data. Work supported by the US Department of Energy, Office of Basic Energy Sciences under Contract No. DE-AC02-98CH10886.
Kapitza resistance of Si/SiO2 interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowen Deng; Aleksandr Chenatynskiy; Marat Khafizov
2014-02-01
A phonon wave packet dynamics method is used to characterize the Kapitza resistance of a Si/SiO2 interface in a Si/SiO2/Si heterostructure. By varying the thickness of SiO2 layer sandwiched between two Si layers, we determine the Kapitza resistance for the Si/SiO2 interface from both wave packet dynamics and a direct, non-equilibrium molecular dynamics approach. The good agreement between the two methods indicates that they have each captured the anharmonic phonon scatterings at the interface. Moreover, detailed analysis provides insights as to how individual phonon mode scatters at the interface and their contribution to the Kapitza resistance.
Cells on Gels: Cell Behavior at the Air-Gel Interface
NASA Astrophysics Data System (ADS)
O'Bryan, Christopher; Hormel, Tristan; Bhattacharjee, Tapomoy; Sawyer, W.; Angelini, Thomas
Numerous different types of cells are often grown at air-liquid interfaces. For example, a common way to create cell spheroids is to disperse cells in a droplet of liquid media that hangs from the lid of a culture dish - the ``hanging drop'' method. Some types of epithelial cells form monolayers at the bottom of hanging drops, instead of spheroids. Corneal epithelial cells stratify and exhibit a tissue-like phenotype when attached to liquid permeable culture surfaces positioned at the air-liquid media interface (air-lifted culture). These widely used culture methods make experimentation challenging - imaging through hanging drops and air-lifted culture dishes is prohibitive. However, similar results may be achieved by culturing cells on hydrogel surfaces at the air-gel interface. In this talk we will describe a method for culturing cells at air-gel interfaces. We seed human corneal epithelial cells (hTCEpi) onto the surfaces of hydrogel networks and jammed microgels, exposed to air. Preliminary observations of cell behavior at the air-gel interface will be presented.
Meenach, Samantha A; Tsoras, Alexandra N; McGarry, Ronald C; Mansour, Heidi M; Hilt, J Zach; Anderson, Kimberly W
2016-04-01
Three-dimensional (3D) lung multicellular spheroids (MCS) in liquid-covered culture (LCC) and air-interface culture (AIC) conditions have both been developed for the evaluation of aerosol anticancer therapeutics in solution and aerosols, respectively. The MCS were formed by seeding lung cancer cells on top of collagen where they formed spheroids due to the prevalence of cell-to-cell interactions. LCC MCS were exposed to paclitaxel (PTX) in media whereas AIC MCS were exposed to dry powder PEGylated phospholipid aerosol microparticles containing paclitaxel. The difference in viability for 2D versus 3D culture for both LCC and AIC was evaluated along with the effects of the particles on lung epithelium via transepithelial electrical resistance (TEER) measurements. For LCC and AIC conditions, the 3D spheroids were more resistant to treatment with higher IC50 values for A549 and H358 cell lines. TEER results initially indicated a decrease in resistance upon drug or particle exposure, however, these values increased over the course of several days indicating the ability of the cells to recover. Overall, these studies offer a comprehensive in vitro evaluation of aerosol particles used in the treatment of lung cancer while introducing a new method for culturing lung cancer MCS in both LCC and AIC conditions.
'Designing Ambient Interactions - Pervasive Ergonomic Interfaces for Ageing Well' (DAI'10)
NASA Astrophysics Data System (ADS)
Geven, Arjan; Prost, Sebastian; Tscheligi, Manfred; Soldatos, John; Gonzalez, Mari Feli
The workshop will focus on novel computer based interaction mechanisms and interfaces, which boost natural interactivity and obviate the need for conventional tedious interfaces. Such interfaces are increasingly used in ambient intelligence environments and related applications, including application boosting elderly cognitive support, cognitive rehabilitation and Ambient Assisted Living (AAL). The aim of the workshop is to provide insights on the technological underpinnings of such interfaces, along with tools and techniques for their design and evaluation.
OPTIMIZING USABILITY OF AN ECONOMIC DECISION SUPPORT TOOL: PROTOTYPE OF THE EQUIPT TOOL.
Cheung, Kei Long; Hiligsmann, Mickaël; Präger, Maximilian; Jones, Teresa; Józwiak-Hagymásy, Judit; Muñoz, Celia; Lester-George, Adam; Pokhrel, Subhash; López-Nicolás, Ángel; Trapero-Bertran, Marta; Evers, Silvia M A A; de Vries, Hein
2018-01-01
Economic decision-support tools can provide valuable information for tobacco control stakeholders, but their usability may impact the adoption of such tools. This study aims to illustrate a mixed-method usability evaluation of an economic decision-support tool for tobacco control, using the EQUIPT ROI tool prototype as a case study. A cross-sectional mixed methods design was used, including a heuristic evaluation, a thinking aloud approach, and a questionnaire testing and exploring the usability of the Return of Investment tool. A total of sixty-six users evaluated the tool (thinking aloud) and completed the questionnaire. For the heuristic evaluation, four experts evaluated the interface. In total twenty-one percent of the respondents perceived good usability. A total of 118 usability problems were identified, from which twenty-six problems were categorized as most severe, indicating high priority to fix them before implementation. Combining user-based and expert-based evaluation methods is recommended as these were shown to identify unique usability problems. The evaluation provides input to optimize usability of a decision-support tool, and may serve as a vantage point for other developers to conduct usability evaluations to refine similar tools before wide-scale implementation. Such studies could reduce implementation gaps by optimizing usability, enhancing in turn the research impact of such interventions.
Hotspot-Centric De Novo Design of Protein Binders
Fleishman, Sarel J.; Corn, Jacob E.; Strauch, Eva-Maria; Whitehead, Timothy A.; Karanicolas, John; Baker, David
2014-01-01
Protein–protein interactions play critical roles in biology, and computational design of interactions could be useful in a range of applications. We describe in detail a general approach to de novo design of protein interactions based on computed, energetically optimized interaction hotspots, which was recently used to produce high-affinity binders of influenza hemagglutinin. We present several alternative approaches to identify and build the key hotspot interactions within both core secondary structural elements and variable loop regions and evaluate the method's performance in natural-interface recapitulation. We show that the method generates binding surfaces that are more conformationally restricted than previous design methods, reducing opportunities for off-target interactions. PMID:21945116
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, Bradley, E-mail: brma7253@colorado.edu; Fornberg, Bengt, E-mail: Fornberg@colorado.edu
In a previous study of seismic modeling with radial basis function-generated finite differences (RBF-FD), we outlined a numerical method for solving 2-D wave equations in domains with material interfaces between different regions. The method was applicable on a mesh-free set of data nodes. It included all information about interfaces within the weights of the stencils (allowing the use of traditional time integrators), and was shown to solve problems of the 2-D elastic wave equation to 3rd-order accuracy. In the present paper, we discuss a refinement of that method that makes it simpler to implement. It can also improve accuracy formore » the case of smoothly-variable model parameter values near interfaces. We give several test cases that demonstrate the method solving 2-D elastic wave equation problems to 4th-order accuracy, even in the presence of smoothly-curved interfaces with jump discontinuities in the model parameters.« less
NASA Astrophysics Data System (ADS)
Martin, Bradley; Fornberg, Bengt
2017-04-01
In a previous study of seismic modeling with radial basis function-generated finite differences (RBF-FD), we outlined a numerical method for solving 2-D wave equations in domains with material interfaces between different regions. The method was applicable on a mesh-free set of data nodes. It included all information about interfaces within the weights of the stencils (allowing the use of traditional time integrators), and was shown to solve problems of the 2-D elastic wave equation to 3rd-order accuracy. In the present paper, we discuss a refinement of that method that makes it simpler to implement. It can also improve accuracy for the case of smoothly-variable model parameter values near interfaces. We give several test cases that demonstrate the method solving 2-D elastic wave equation problems to 4th-order accuracy, even in the presence of smoothly-curved interfaces with jump discontinuities in the model parameters.
The Design and Evaluation of a Large-Scale Real-Walking Locomotion Interface
Peck, Tabitha C.; Fuchs, Henry; Whitton, Mary C.
2014-01-01
Redirected Free Exploration with Distractors (RFED) is a large-scale real-walking locomotion interface developed to enable people to walk freely in virtual environments that are larger than the tracked space in their facility. This paper describes the RFED system in detail and reports on a user study that evaluated RFED by comparing it to walking-in-place and joystick interfaces. The RFED system is composed of two major components, redirection and distractors. This paper discusses design challenges, implementation details, and lessons learned during the development of two working RFED systems. The evaluation study examined the effect of the locomotion interface on users’ cognitive performance on navigation and wayfinding measures. The results suggest that participants using RFED were significantly better at navigating and wayfinding through virtual mazes than participants using walking-in-place and joystick interfaces. Participants traveled shorter distances, made fewer wrong turns, pointed to hidden targets more accurately and more quickly, and were able to place and label targets on maps more accurately, and more accurately estimate the virtual environment size. PMID:22184262
Yamaguchi, Yoko; Shiota, Makoto; FuJii, Masaki; Sekiya, Michi; Ozeki, Masahiko
2016-01-01
Primary stability after implant placement is essential for osseointegration. It is important to understand the bone/implant interface for analyzing the influence of implant design on primary stability. In this study rigid polyurethane foam is used as artificial bone to evaluate the bone-implant interface and to identify where the torque is being generated during placement. Five implant systems-Straumann-Standard (ST), Straumann-Bone Level (BL), Straumann-Tapered Effect (TE), Nobel Biocare-Brånemark MKIII (MK3), and Nobel Biocare-Brånemark MKIV (MK4)-were used for this experiment. Artificial bone blocks were prepared and the implant was installed. After placement, a metal jig and one side artificial bone block were removed and then the implant embedded in the artificial bone was exposed for observing the bone-implant interface. A digital micro-analyzer was used for observing the contact interface. The insertion torque values were 39.35, 23.78, 12.53, 26.35, and 17.79 N cm for MK4, BL, ST, TE, and MK3, respectively. In ST, MK3, TE, MK4, and BL the white layer areas were 61 × 103 μm(2), 37 × 103 μm(2), 103 × 103 μm(2) in the tapered portion and 84 × 03 μm(2) in the parallel portion, 134 × 103 μm(2), and 98 × 103 μm(2) in the tapered portion and 87 × 103 μm(2) in the parallel portion, respectively. The direct observation method of the implant/artificial bone interface is a simple and useful method that enables the identification of the area where implant retention occurs. A white layer at the site of stress concentration during implant placement was identified and the magnitude of the stress was quantitatively estimated. The site where the highest torque occurred was the area from the thread crest to the thread root and the under and lateral aspect of the platform. The artificial bone debris created by the self-tapping blade accumulated in both the cutting chamber and in the space between the threads and artificial bone.
Understanding the influence of capillary waves on solvation at the liquid-vapor interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rane, Kaustubh, E-mail: rane@csi.tu-darmstadt.de; Vegt, Nico F. A. van der
2016-03-21
This work investigates the question if surface capillary waves (CWs) affect interfacial solvation thermodynamic properties that determine the propensity of small molecules toward the liquid-vapor interface. We focus on (1) the evaluation of these properties from molecular simulations in a practical manner and (2) understanding them from the perspective of theories in solvation thermodynamics, especially solvent reorganization effects. Concerning the former objective, we propose a computational method that exploits the relationship between an external field acting on the liquid-vapor interface and the magnitude of CWs. The system considered contains the solvent, an externally applied field (f) and the solute moleculemore » fixed at a particular location. The magnitude of f is selected to induce changes in CWs. The difference between the solvation free energies computed in the presence and in the absence of f is then shown to quantify the contribution of CWs to interfacial solvation. We describe the implementation of this method in the canonical ensemble by using a Lennard-Jones solvent and a non-ionic solute. Results are shown for three types of solutes that differ in the nature of short-ranged repulsive (hard-core) interactions. Overall, we observe that CWs have a negligible or very small effect on the interfacial solvation free energy of a solute molecule fixed near the liquid-vapor interface for the above systems. We also explain how the effects of pinning or dampening of CWs caused by a fixed solute are effectively compensated and do not contribute to the solvation free energy.« less
Greene, Patrick T.; Schofield, Samuel P.; Nourgaliev, Robert
2017-01-27
A new mesh smoothing method designed to cluster cells near a dynamically evolving interface is presented. The method is based on weighted condition number mesh relaxation with the weight function computed from a level set representation of the interface. The weight function is expressed as a Taylor series based discontinuous Galerkin projection, which makes the computation of the derivatives of the weight function needed during the condition number optimization process a trivial matter. For cases when a level set is not available, a fast method for generating a low-order level set from discrete cell-centered fields, such as a volume fractionmore » or index function, is provided. Results show that the low-order level set works equally well as the actual level set for mesh smoothing. Meshes generated for a number of interface geometries are presented, including cases with multiple level sets. Lastly, dynamic cases with moving interfaces show the new method is capable of maintaining a desired resolution near the interface with an acceptable number of relaxation iterations per time step, which demonstrates the method's potential to be used as a mesh relaxer for arbitrary Lagrangian Eulerian (ALE) methods.« less
Assessing the Student-Instructional Setting Interface Using an Eco-Behavioral Observation System.
ERIC Educational Resources Information Center
Hendrickson, Jo M.
1992-01-01
An eco-behavioral observation system was developed for use with students with behavior disorders or emotional disturbances. Discussed are the ecosystem definition, the student-instructional setting interface, and the assessment procedure, including evaluation of the quality of academic responding, program evaluation, staff development, and…
A Question of Interface Design: How Do Online Service GUIs Measure Up?
ERIC Educational Resources Information Center
Head, Alison J.
1997-01-01
Describes recent improvements in graphical user interfaces (GUIs) offered by online services. Highlights include design considerations, including computer engineering capabilities and users' abilities; fundamental GUI design principles; user empowerment; visual communication and interaction; and an evaluation of online search interfaces. (LRW)
NASA Astrophysics Data System (ADS)
Fujimura, Nobuyuki; Ohta, Akio; Ikeda, Mitsuhisa; Makihara, Katsunori; Miyazaki, Seiichi
2018-04-01
The electrical dipole moment at an ultrathin high-k (HfO2, Al2O3, TiO2, Y2O3, and SrO)/SiO2 interface and its correlation with the oxygen density ratio at the interface have been directly evaluated by X-ray photoelectron spectroscopy (XPS) under monochromatized Al Kα radiation. The electrical dipole moment at the high-k/SiO2 interface has been measured from the change in the cut-off energy of secondary photoelectrons. Moreover, the oxygen density ratio at the interface between high-k and SiO2 has been estimated from cation core-line signals, such as Hf 4f, Al 2p, Y 3d, Ti 2p, Sr 3d, and Si 2p. We have experimentally clarified the relationship between the measured electrical dipole moment and the oxygen density ratio at the high-k/SiO2 interface.
Multiple methods integration for structural mechanics analysis and design
NASA Technical Reports Server (NTRS)
Housner, J. M.; Aminpour, M. A.
1991-01-01
A new research area of multiple methods integration is proposed for joining diverse methods of structural mechanics analysis which interact with one another. Three categories of multiple methods are defined: those in which a physical interface are well defined; those in which a physical interface is not well-defined, but selected; and those in which the interface is a mathematical transformation. Two fundamental integration procedures are presented that can be extended to integrate various methods (e.g., finite elements, Rayleigh Ritz, Galerkin, and integral methods) with one another. Since the finite element method will likely be the major method to be integrated, its enhanced robustness under element distortion is also examined and a new robust shell element is demonstrated.
M-Adapting Low Order Mimetic Finite Differences for Dielectric Interface Problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGregor, Duncan A.; Gyrya, Vitaliy; Manzini, Gianmarco
2016-03-07
We consider a problem of reducing numerical dispersion for electromagnetic wave in the domain with two materials separated by a at interface in 2D with a factor of two di erence in wave speed. The computational mesh in the homogeneous parts of the domain away from the interface consists of square elements. Here the method construction is based on m-adaptation construction in homogeneous domain that leads to fourth-order numerical dispersion (vs. second order in non-optimized method). The size of the elements in two domains also di ers by a factor of two, so as to preserve the same value ofmore » Courant number in each. Near the interface where two meshes merge the mesh with larger elements consists of degenerate pentagons. We demonstrate that prior to m-adaptation the accuracy of the method falls from second to rst due to breaking of symmetry in the mesh. Next we develop m-adaptation framework for the interface region and devise an optimization criteria. We prove that for the interface problem m-adaptation cannot produce increase in method accuracy. This is in contrast to homogeneous medium where m-adaptation can increase accuracy by two orders.« less
Unanticipated C=C bonds in covalent monolayers on silicon revealed by NEXAFS.
Lee, Michael V; Lee, Jonathan R I; Brehmer, Daniel E; Linford, Matthew R; Willey, Trevor M
2010-02-02
Interfaces are crucial to material properties. In the case of covalent organic monolayers on silicon, molecular structure at the interface controls the self-assembly of the monolayers, which in turn influences the optical properties and electrical transport. These properties intrinsically affect their application in biology, tribology, optics, and electronics. We use near-edge X-ray absorption fine structure spectroscopy to show that the most basic covalent monolayers formed from 1-alkenes on silicon retain a double bond in one-fifth to two-fifths of the resultant molecules. Unsaturation in the predominantly saturated monolayers will perturb the regular order and affect the dependent properties. The presence of unsaturation in monolayers produced by two different methods also prompts the re-evaluation of other radical-based mechanisms for forming covalent monolayers on silicon.
Griffon, Nicolas; Kerdelhué, Gaétan; Hamek, Saliha; Hassler, Sylvain; Boog, César; Lamy, Jean-Baptiste; Duclos, Catherine; Venot, Alain; Darmoni, Stéfan J
2014-10-01
Doc'CISMeF (DC) is a semantic search engine used to find resources in CISMeF-BP, a quality controlled health gateway, which gathers guidelines available on the internet in French. Visualization of Concepts in Medicine (VCM) is an iconic language that may ease information retrieval tasks. This study aimed to describe the creation and evaluation of an interface integrating VCM in DC in order to make this search engine much easier to use. Focus groups were organized to suggest ways to enhance information retrieval tasks using VCM in DC. A VCM interface was created and improved using the ergonomic evaluation approach. 20 physicians were recruited to compare the VCM interface with the non-VCM one. Each evaluator answered two different clinical scenarios in each interface. The ability and time taken to select a relevant resource were recorded and compared. A usability analysis was performed using the System Usability Scale (SUS). The VCM interface contains a filter based on icons, and icons describing each resource according to focus group recommendations. Some ergonomic issues were resolved before evaluation. Use of VCM significantly increased the success of information retrieval tasks (OR=11; 95% CI 1.4 to 507). Nonetheless, it took significantly more time to find a relevant resource with VCM interface (101 vs 65 s; p=0.02). SUS revealed 'good' usability with an average score of 74/100. VCM was successfully implemented in DC as an option. It increased the success rate of information retrieval tasks, despite requiring slightly more time, and was well accepted by end-users. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Tsunoda, Takaya; Suzuki, Keigo; Saitoh, Takahiro
2018-04-01
This study develops a method to visualize the state of steel-concrete interface with ultrasonic testing. Scattered waves are obtained by the UT pitch-catch mode from the surface of the concrete. Discrete wavelet transform is applied in order to extract echoes scattered from the steel-concrete interface. Then Linearized Inverse Scattering Methods are used for imaging the interface. The results show that LISM with Born and Kirchhoff approximation provide clear images for the target.
Desai, Shrikar R.; Singh, Rika; Karthikeyan, I.
2013-01-01
Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm–diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results. PMID:24174759
Ye, Zhan; Kadolph, Christopher; Strenn, Robert; Wall, Daniel; McPherson, Elizabeth; Lin, Simon
2015-01-01
Background Identification and evaluation of incidental findings in patients following whole exome (WGS) or whole genome sequencing (WGS) is challenging for both practicing physicians and researchers. The American College of Medical Genetics and Genomics (ACMG) recently recommended a list of reportable incidental genetic findings. However, no informatics tools are currently available to support evaluation of incidental findings in next-generation sequencing data. Methods The Wisconsin Hierarchical Analysis Tool for Incidental Findings (WHATIF), was developed as a stand-alone Windows-based desktop executable, to support the interactive analysis of incidental findings in the context of the ACMG recommendations. WHATIF integrates the European Bioinformatics Institute Variant Effect Predictor (VEP) tool for biological interpretation and the National Center for Biotechnology Information ClinVar tool for clinical interpretation. Results An open-source desktop program was created to annotate incidental findings and present the results with a user-friendly interface. Further, a meaningful index (WHATIF Index) was devised for each gene to facilitate ranking of the relative importance of the variants and estimate the potential workload associated with further evaluation of the variants. Our WHATIF application is available at: http://tinyurl.com/WHATIF-SOFTWARE Conclusions The WHATIF application offers a user-friendly interface and allows users to investigate the extracted variant information efficiently and intuitively while always accessing the up to date information on variants via application programming interfaces (API) connections. WHATIF’s highly flexible design and straightforward implementation aids users in customizing the source code to meet their own special needs. PMID:25890833
Bourlier, Christophe; Kubické, Gildas; Déchamps, Nicolas
2008-04-01
A fast, exact numerical method based on the method of moments (MM) is developed to calculate the scattering from an object below a randomly rough surface. Déchamps et al. [J. Opt. Soc. Am. A23, 359 (2006)] have recently developed the PILE (propagation-inside-layer expansion) method for a stack of two one-dimensional rough interfaces separating homogeneous media. From the inversion of the impedance matrix by block (in which two impedance matrices of each interface and two coupling matrices are involved), this method allows one to calculate separately and exactly the multiple-scattering contributions inside the layer in which the inverses of the impedance matrices of each interface are involved. Our purpose here is to apply this method for an object below a rough surface. In addition, to invert a matrix of large size, the forward-backward spectral acceleration (FB-SA) approach of complexity O(N) (N is the number of unknowns on the interface) proposed by Chou and Johnson [Radio Sci.33, 1277 (1998)] is applied. The new method, PILE combined with FB-SA, is tested on perfectly conducting circular and elliptic cylinders located below a dielectric rough interface obeying a Gaussian process with Gaussian and exponential height autocorrelation functions.
Nakajima, Sawako; Ino, Shuichi; Ifukube, Tohru
2007-01-01
Mixed Reality (MR) technologies have recently been explored in many areas of Human-Machine Interface (HMI) such as medicine, manufacturing, entertainment and education. However MR sickness, a kind of motion sickness is caused by sensory conflicts between the real world and virtual world. The purpose of this paper is to find out a new evaluation method of motion and MR sickness. This paper investigates a relationship between the whole-body vibration related to MR technologies and the motion aftereffect (MAE) phenomenon in the human visual system. This MR environment is modeled after advanced driver assistance systems in near-future vehicles. The seated subjects in the MR simulator were shaken in the pitch direction ranging from 0.1 to 2.0 Hz. Results show that MAE is useful for evaluation of MR sickness incidence. In addition, a method to reduce the MR sickness by auditory stimulation is proposed.
Goal-recognition-based adaptive brain-computer interface for navigating immersive robotic systems.
Abu-Alqumsan, Mohammad; Ebert, Felix; Peer, Angelika
2017-06-01
This work proposes principled strategies for self-adaptations in EEG-based Brain-computer interfaces (BCIs) as a way out of the bandwidth bottleneck resulting from the considerable mismatch between the low-bandwidth interface and the bandwidth-hungry application, and a way to enable fluent and intuitive interaction in embodiment systems. The main focus is laid upon inferring the hidden target goals of users while navigating in a remote environment as a basis for possible adaptations. To reason about possible user goals, a general user-agnostic Bayesian update rule is devised to be recursively applied upon the arrival of evidences, i.e. user input and user gaze. Experiments were conducted with healthy subjects within robotic embodiment settings to evaluate the proposed method. These experiments varied along three factors: the type of the robot/environment (simulated and physical), the type of the interface (keyboard or BCI), and the way goal recognition (GR) is used to guide a simple shared control (SC) driving scheme. Our results show that the proposed GR algorithm is able to track and infer the hidden user goals with relatively high precision and recall. Further, the realized SC driving scheme benefits from the output of the GR system and is able to reduce the user effort needed to accomplish the assigned tasks. Despite the fact that the BCI requires higher effort compared to the keyboard conditions, most subjects were able to complete the assigned tasks, and the proposed GR system is additionally shown able to handle the uncertainty in user input during SSVEP-based interaction. The SC application of the belief vector indicates that the benefits of the GR module are more pronounced for BCIs, compared to the keyboard interface. Being based on intuitive heuristics that model the behavior of the general population during the execution of navigation tasks, the proposed GR method can be used without prior tuning for the individual users. The proposed methods can be easily integrated in devising more advanced SC schemes and/or strategies for automatic BCI self-adaptations.
Goal-recognition-based adaptive brain-computer interface for navigating immersive robotic systems
NASA Astrophysics Data System (ADS)
Abu-Alqumsan, Mohammad; Ebert, Felix; Peer, Angelika
2017-06-01
Objective. This work proposes principled strategies for self-adaptations in EEG-based Brain-computer interfaces (BCIs) as a way out of the bandwidth bottleneck resulting from the considerable mismatch between the low-bandwidth interface and the bandwidth-hungry application, and a way to enable fluent and intuitive interaction in embodiment systems. The main focus is laid upon inferring the hidden target goals of users while navigating in a remote environment as a basis for possible adaptations. Approach. To reason about possible user goals, a general user-agnostic Bayesian update rule is devised to be recursively applied upon the arrival of evidences, i.e. user input and user gaze. Experiments were conducted with healthy subjects within robotic embodiment settings to evaluate the proposed method. These experiments varied along three factors: the type of the robot/environment (simulated and physical), the type of the interface (keyboard or BCI), and the way goal recognition (GR) is used to guide a simple shared control (SC) driving scheme. Main results. Our results show that the proposed GR algorithm is able to track and infer the hidden user goals with relatively high precision and recall. Further, the realized SC driving scheme benefits from the output of the GR system and is able to reduce the user effort needed to accomplish the assigned tasks. Despite the fact that the BCI requires higher effort compared to the keyboard conditions, most subjects were able to complete the assigned tasks, and the proposed GR system is additionally shown able to handle the uncertainty in user input during SSVEP-based interaction. The SC application of the belief vector indicates that the benefits of the GR module are more pronounced for BCIs, compared to the keyboard interface. Significance. Being based on intuitive heuristics that model the behavior of the general population during the execution of navigation tasks, the proposed GR method can be used without prior tuning for the individual users. The proposed methods can be easily integrated in devising more advanced SC schemes and/or strategies for automatic BCI self-adaptations.
Fast Numerical Methods for the Design of Layered Photonic Structures with Rough Interfaces
NASA Technical Reports Server (NTRS)
Komarevskiy, Nikolay; Braginsky, Leonid; Shklover, Valery; Hafner, Christian; Lawson, John
2011-01-01
Modified boundary conditions (MBC) and a multilayer approach (MA) are proposed as fast and efficient numerical methods for the design of 1D photonic structures with rough interfaces. These methods are applicable for the structures, composed of materials with arbitrary permittivity tensor. MBC and MA are numerically validated on different types of interface roughness and permittivities of the constituent materials. The proposed methods can be combined with the 4x4 scattering matrix method as a field solver and an evolutionary strategy as an optimizer. The resulted optimization procedure is fast, accurate, numerically stable and can be used to design structures for various applications.
Surface thermodynamics of planar, cylindrical, and spherical vapour-liquid interfaces of water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lau, Gabriel V.; Müller, Erich A.; Jackson, George
2015-03-21
The test-area (TA) perturbation approach has been gaining popularity as a methodology for the direct computation of the interfacial tension in molecular simulation. Though originally implemented for planar interfaces, the TA approach has also been used to analyze the interfacial properties of curved liquid interfaces. Here, we provide an interpretation of the TA method taking the view that it corresponds to the change in free energy under a transformation of the spatial metric for an affine distortion. By expressing the change in configurational energy of a molecular configuration as a Taylor expansion in the distortion parameter, compact relations are derivedmore » for the interfacial tension and its energetic and entropic components for three different geometries: planar, cylindrical, and spherical fluid interfaces. While the tensions of the planar and cylindrical geometries are characterized by first-order changes in the energy, that of the spherical interface depends on second-order contributions. We show that a greater statistical uncertainty is to be expected when calculating the thermodynamic properties of a spherical interface than for the planar and cylindrical cases, and the evaluation of the separate entropic and energetic contributions poses a greater computational challenge than the tension itself. The methodology is employed to determine the vapour-liquid interfacial tension of TIP4P/2005 water at 293 K by molecular dynamics simulation for planar, cylindrical, and spherical geometries. A weak peak in the curvature dependence of the tension is observed in the case of cylindrical threads of condensed liquid at a radius of about 8 Å, below which the tension is found to decrease again. In the case of spherical drops, a marked decrease in the tension from the planar limit is found for radii below ∼ 15 Å; there is no indication of a maximum in the tension with increasing curvature. The vapour-liquid interfacial tension tends towards the planar limit for large system sizes for both the cylindrical and spherical cases. Estimates of the entropic and energetic contributions are also evaluated for the planar and cylindrical geometries and their magnitudes are in line with the expectations of our simple analysis.« less
Tensile and bending fatigue of the adhesive interface to dentin.
Belli, Renan; Baratieri, Luiz Narciso; Braem, Marc; Petschelt, Anselm; Lohbauer, Ulrich
2010-12-01
The aim of this study was to evaluate the fatigue limits of the dentin-composite interfaces established either with an etch-and-rinse or an one-step self-etch adhesive systems under tensile and bending configurations. Flat specimens (1.2 mm×5 mm×35 mm) were prepared using a plexiglass mold where dentin sections from human third molars were bonded to a resin composite, exhibiting the interface centrally located. Syntac Classic and G-Bond were used as adhesives and applied according to the manufacturer's instructions. The fluorochrome Rhodamine B was added to the adhesives to allow for fractographic evaluation. Tensile strength was measured in an universal testing machine and the bending strength (n=15) in a Flex machine (Flex, University of Antwerp, Belgium), respectively. Tensile (TFL) and bending fatigue limits (BFL) (n=25) were determined under wet conditions for 10(4) cycles following a staircase approach. Interface morphology and fracture mechanisms were observed using light, confocal laser scanning and scanning electron microscopy. Statistical analysis was performed using three-way ANOVA (mod LSD test, p<0.05). Tensile and bending characteristic strengths at 63.2% failure probability for Syntac were 23.8 MPa and 71.5 MPa, and 24.7 MPa and 72.3 MPa for G-Bond, respectively. Regarding the applied methods, no significant differences were detected between adhesives. However, fatigue limits for G-Bond (TFL=5.9 MPa; BFL=36.2 MPa) were significantly reduced when compared to Syntac (TFL=12.6 MPa; BFL=49.7 MPa). Fracture modes of Syntac were generally of adhesive nature, between the adhesive resin and dentin, while G-Bond showed fracture planes involving the adhesive-dentin interface and the adhesive resin. Cyclic loading under tensile and bending configurations led to a significant strength degradation, with a more pronounced fatigue limit decrease for G-Bond. The greater decrease in fracture strength was observed in the tensile configuration. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
System and method for interfacing large-area electronics with integrated circuit devices
Verma, Naveen; Glisic, Branko; Sturm, James; Wagner, Sigurd
2016-07-12
A system and method for interfacing large-area electronics with integrated circuit devices is provided. The system may be implemented in an electronic device including a large area electronic (LAE) device disposed on a substrate. An integrated circuit IC is disposed on the substrate. A non-contact interface is disposed on the substrate and coupled between the LAE device and the IC. The non-contact interface is configured to provide at least one of a data acquisition path or control path between the LAE device and the IC.
Transforming Collaborative Process Models into Interface Process Models by Applying an MDA Approach
NASA Astrophysics Data System (ADS)
Lazarte, Ivanna M.; Chiotti, Omar; Villarreal, Pablo D.
Collaborative business models among enterprises require defining collaborative business processes. Enterprises implement B2B collaborations to execute these processes. In B2B collaborations the integration and interoperability of processes and systems of the enterprises are required to support the execution of collaborative processes. From a collaborative process model, which describes the global view of the enterprise interactions, each enterprise must define the interface process that represents the role it performs in the collaborative process in order to implement the process in a Business Process Management System. Hence, in this work we propose a method for the automatic generation of the interface process model of each enterprise from a collaborative process model. This method is based on a Model-Driven Architecture to transform collaborative process models into interface process models. By applying this method, interface processes are guaranteed to be interoperable and defined according to a collaborative process.
Human-computer interface including haptically controlled interactions
Anderson, Thomas G.
2005-10-11
The present invention provides a method of human-computer interfacing that provides haptic feedback to control interface interactions such as scrolling or zooming within an application. Haptic feedback in the present method allows the user more intuitive control of the interface interactions, and allows the user's visual focus to remain on the application. The method comprises providing a control domain within which the user can control interactions. For example, a haptic boundary can be provided corresponding to scrollable or scalable portions of the application domain. The user can position a cursor near such a boundary, feeling its presence haptically (reducing the requirement for visual attention for control of scrolling of the display). The user can then apply force relative to the boundary, causing the interface to scroll the domain. The rate of scrolling can be related to the magnitude of applied force, providing the user with additional intuitive, non-visual control of scrolling.
NASA Astrophysics Data System (ADS)
Coco, Armando; Russo, Giovanni
2018-05-01
In this paper we propose a second-order accurate numerical method to solve elliptic problems with discontinuous coefficients (with general non-homogeneous jumps in the solution and its gradient) in 2D and 3D. The method consists of a finite-difference method on a Cartesian grid in which complex geometries (boundaries and interfaces) are embedded, and is second order accurate in the solution and the gradient itself. In order to avoid the drop in accuracy caused by the discontinuity of the coefficients across the interface, two numerical values are assigned on grid points that are close to the interface: a real value, that represents the numerical solution on that grid point, and a ghost value, that represents the numerical solution extrapolated from the other side of the interface, obtained by enforcing the assigned non-homogeneous jump conditions on the solution and its flux. The method is also extended to the case of matrix coefficient. The linear system arising from the discretization is solved by an efficient multigrid approach. Unlike the 1D case, grid points are not necessarily aligned with the normal derivative and therefore suitable stencils must be chosen to discretize interface conditions in order to achieve second order accuracy in the solution and its gradient. A proper treatment of the interface conditions will allow the multigrid to attain the optimal convergence factor, comparable with the one obtained by Local Fourier Analysis for rectangular domains. The method is robust enough to handle large jump in the coefficients: order of accuracy, monotonicity of the errors and good convergence factor are maintained by the scheme.
Iuchi, Terumi; Nakajima, Yukari; Fukuda, Moriyoshi; Matsuo, Junko; Okamoto, Hiroyuki; Sanada, Hiromi; Sugama, Junko
2014-05-01
Bed sheets generate high surface tension across the support surface and increase pressure to the body through a process known as the hammock effect. Using an anatomical model and a loading device characterized by extreme bony prominences, the present study compared pressure distributions on support surfaces across different bed making methods and bed sheet materials to determine the factors that influence pressure distribution. The model was placed on a pressure mapping system (CONFORMat; NITTA Corp., Osaka, Japan), and interface pressure was measured. Bed sheet elasticity and friction between the support surface and the bed sheets were also measured. For maximum interface pressure, the relative values of the following methods were higher than those of the control method, which did not use any bed sheets: cotton sheets with hospital corners (1.28, p = 0.02), polyester with no corners (1.29, p = 0.01), cotton with no corners (1.31, p = 0.003), and fitted polyester sheets (1.35, p = 0.002). Stepwise multiple regression analysis indicated that maximum interface pressure was negatively correlated with bed sheet elasticity (R(2) = 0.74). A statistically significant negative correlation was observed between maximum interface pressure and immersion depth, which was measured using the loading device (r = -0.40 and p = 0.04). We found that several combinations of bed making methods and bed sheet materials induced maximum interface pressures greater than those observed for the control method. Bed sheet materials influenced maximum interface pressure, and bed sheet elasticity was particularly important in reducing maximum interface pressure. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Topical Interface between Managerial Finance and Managerial Accounting.
ERIC Educational Resources Information Center
Williams, Norman C.; Swanson, G. A.
1988-01-01
The authors present a method to examine the interfaces between business courses for redundancy. The method is demonstrated by examining the content in managerial finance and managerial accounting courses. A decision model application of analysis, expert judgment, and synthesis are incorporated in this method. (CH)
Druhl, Emily; Polepalli Ramesh, Balaji; Houston, Thomas K; Brandt, Cynthia A; Zulman, Donna M; Vimalananda, Varsha G; Malkani, Samir; Yu, Hong
2018-01-01
Background Many health care systems now allow patients to access their electronic health record (EHR) notes online through patient portals. Medical jargon in EHR notes can confuse patients, which may interfere with potential benefits of patient access to EHR notes. Objective The aim of this study was to develop and evaluate the usability and content quality of NoteAid, a Web-based natural language processing system that links medical terms in EHR notes to lay definitions, that is, definitions easily understood by lay people. Methods NoteAid incorporates two core components: CoDeMed, a lexical resource of lay definitions for medical terms, and MedLink, a computational unit that links medical terms to lay definitions. We developed innovative computational methods, including an adapted distant supervision algorithm to prioritize medical terms important for EHR comprehension to facilitate the effort of building CoDeMed. Ten physician domain experts evaluated the user interface and content quality of NoteAid. The evaluation protocol included a cognitive walkthrough session and a postsession questionnaire. Physician feedback sessions were audio-recorded. We used standard content analysis methods to analyze qualitative data from these sessions. Results Physician feedback was mixed. Positive feedback on NoteAid included (1) Easy to use, (2) Good visual display, (3) Satisfactory system speed, and (4) Adequate lay definitions. Opportunities for improvement arising from evaluation sessions and feedback included (1) improving the display of definitions for partially matched terms, (2) including more medical terms in CoDeMed, (3) improving the handling of terms whose definitions vary depending on different contexts, and (4) standardizing the scope of definitions for medicines. On the basis of these results, we have improved NoteAid’s user interface and a number of definitions, and added 4502 more definitions in CoDeMed. Conclusions Physician evaluation yielded useful feedback for content validation and refinement of this innovative tool that has the potential to improve patient EHR comprehension and experience using patient portals. Future ongoing work will develop algorithms to handle ambiguous medical terms and test and evaluate NoteAid with patients. PMID:29358159
Statistical modeling for visualization evaluation through data fusion.
Chen, Xiaoyu; Jin, Ran
2017-11-01
There is a high demand of data visualization providing insights to users in various applications. However, a consistent, online visualization evaluation method to quantify mental workload or user preference is lacking, which leads to an inefficient visualization and user interface design process. Recently, the advancement of interactive and sensing technologies makes the electroencephalogram (EEG) signals, eye movements as well as visualization logs available in user-centered evaluation. This paper proposes a data fusion model and the application procedure for quantitative and online visualization evaluation. 15 participants joined the study based on three different visualization designs. The results provide a regularized regression model which can accurately predict the user's evaluation of task complexity, and indicate the significance of all three types of sensing data sets for visualization evaluation. This model can be widely applied to data visualization evaluation, and other user-centered designs evaluation and data analysis in human factors and ergonomics. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Comparison among various software for LMS growth curve fitting methods].
Han, Lin; Wu, Wenhong; Wei, Qiuxia
2015-03-01
To explore the methods to realize the growth curve fitting of coefficients of skewness-median-coefficient of variation (LMS) using different software, and to optimize growth curve statistical method for grass-root child and adolescent staffs. Regular physical examination data of head circumference for normal infants aging 3, 6, 9 and 12 months in Baotou City were analyzed. Statistical software such as SAS, R, STATA and SPSS were used to fit the LMS growth curve and the results were evaluated upon the user 's convenience, study circle, user interface, results display forms, software update and maintenance and so on. Growth curve fitting results showed the same calculation outcome and each of statistical software had its own advantages and disadvantages. With all the evaluation aspects in consideration, R software excelled others in LMS growth curve fitting. R software have the advantage over other software in grass roots child and adolescent staff.
Area health education center libraries and medical school libraries: establishing an interface.
Bandy, C R
1978-01-01
Establishing an interface between area health education center (AHEC) libraries and medical school libraries requires careful planning, including: the overall plan, needs assessment, resource evaluation, a developmental plan, monitoring and evaluation, institutional agreements, and publicity. This paper reports on the development of AHEC libraries in North Dakota. PMID:708958
NASA Technical Reports Server (NTRS)
Dorris, William J.; Hairr, John W.; Huang, Jui-Tien; Ingram, J. Edward; Shah, Bharat M.
1992-01-01
Non-linear analysis methods were adapted and incorporated in a finite element based DIAL code. These methods are necessary to evaluate the global response of a stiffened structure under combined in-plane and out-of-plane loading. These methods include the Arc Length method and target point analysis procedure. A new interface material model was implemented that can model elastic-plastic behavior of the bond adhesive. Direct application of this method is in skin/stiffener interface failure assessment. Addition of the AML (angle minus longitudinal or load) failure procedure and Hasin's failure criteria provides added capability in the failure predictions. Interactive Stiffened Panel Analysis modules were developed as interactive pre-and post-processors. Each module provides the means of performing self-initiated finite elements based analysis of primary structures such as a flat or curved stiffened panel; a corrugated flat sandwich panel; and a curved geodesic fuselage panel. This module brings finite element analysis into the design of composite structures without the requirement for the user to know much about the techniques and procedures needed to actually perform a finite element analysis from scratch. An interactive finite element code was developed to predict bolted joint strength considering material and geometrical non-linearity. The developed method conducts an ultimate strength failure analysis using a set of material degradation models.
Evaluating the Effectiveness of Immersive Interfaces for Combat Training
2015-07-10
on pre- test and post - test improvement. Both test groups improved, but at the 95% level neither method of instruction...evenly separated into the two groups and then tested on the final day of the experiment. The results from this final assessment are used to determine... post - test on a competitive basis with two samples of ten subjects to prove effectives. This paper also uses a pre- test and post - test regimen on
Physical Ability-Task Performance Models: Assessing the Risk of Omitted Variable Bias
2008-09-15
association was evaluated in a study of simulated job performance in men and women. The study measured four major abilities, Static Strength (SS), Dynamic...ability- performance interface for physical tasks. Methods Sample Participants were active-duty naval personnel (64 men , 38 women) between ages 20...bench with feet flat on the floor. Position was adjusted so the bar was between the shoulder and nipple line. Handles were gripped at a comfortable
Study program for encapsulation materials interface for low-cost solar array
NASA Technical Reports Server (NTRS)
Kaelble, D. H.; Mansfeld, F. B.; Kendig, M.; Leung, C.
1981-01-01
The service integrity of the bonded interface in solar cell modules used in solar arrays is addressed. The development of AC impedance as a nondestructive evaluation (NDE) methodology for solar arrays is reported along with development of corrosion models and materials selection criteria for corrosion resistant interfaces.
AlphaSpace: Fragment-Centric Topographical Mapping To Target Protein–Protein Interaction Interfaces
2016-01-01
Inhibition of protein–protein interactions (PPIs) is emerging as a promising therapeutic strategy despite the difficulty in targeting such interfaces with drug-like small molecules. PPIs generally feature large and flat binding surfaces as compared to typical drug targets. These features pose a challenge for structural characterization of the surface using geometry-based pocket-detection methods. An attractive mapping strategy—that builds on the principles of fragment-based drug discovery (FBDD)—is to detect the fragment-centric modularity at the protein surface and then characterize the large PPI interface as a set of localized, fragment-targetable interaction regions. Here, we introduce AlphaSpace, a computational analysis tool designed for fragment-centric topographical mapping (FCTM) of PPI interfaces. Our approach uses the alpha sphere construct, a geometric feature of a protein’s Voronoi diagram, to map out concave interaction space at the protein surface. We introduce two new features—alpha-atom and alpha-space—and the concept of the alpha-atom/alpha-space pair to rank pockets for fragment-targetability and to facilitate the evaluation of pocket/fragment complementarity. The resulting high-resolution interfacial map of targetable pocket space can be used to guide the rational design and optimization of small molecule or biomimetic PPI inhibitors. PMID:26225450
Imunohistological aspects of the tissue around dental implants
NASA Astrophysics Data System (ADS)
Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru
2016-03-01
Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.