Sample records for interference test cwit

  1. Atypical performance patterns on Delis-Kaplan Executive Functioning System Color-Word Interference Test: Cognitive switching and learning ability in older adults.

    PubMed

    Berg, Jody-Lynn; Swan, Natasha M; Banks, Sarah J; Miller, Justin B

    2016-09-01

    Cognitive set shifting requires flexible application of lower level processes. The Delis-Kaplan Executive Functioning System (DKEFS) Color-Word Interference Test (CWIT) is commonly used to clinically assess cognitive set shifting. An atypical pattern of performance has been observed on the CWIT; a subset of individuals perform faster, with equal or fewer errors, on the more difficult inhibition/switching than the inhibition trial. This study seeks to explore the cognitive underpinnings of this atypical pattern. It is hypothesized that atypical patterns on CWIT will be associated with better performance on underlying cognitive measures of attention, working memory, and learning when compared to typical CWIT patterns. Records from 239 clinical referrals (age: M = 68.09 years, SD = 10.62; education: M = 14.87 years, SD = 2.73) seen for a neuropsychological evaluation as part of diagnostic work up in an outpatient dementia and movement disorders clinic were sampled. The standard battery of tests included measures of attention, learning, fluency, executive functioning, and working memory. Analyses of variance (ANOVAs) were conducted to compare the cognitive performance of those with typical versus atypical CWIT patterns. An atypical pattern of performance was confirmed in 23% of our sample. Analyses revealed a significant group difference in acquisition of information on both nonverbal (Brief Visuospatial Memory Test-Revised, BVMT-R total recall), F(1, 213) = 16.61, p < .001, and verbal (Hopkins Verbal Learning Test-Revised, HVLT-R total recall) learning tasks, F(1, 181) = 6.43, p < .01, and semantic fluency (Animal Naming), F(1, 232) = 7.57, p = .006, with the atypical group performing better on each task. Effect sizes were larger for nonverbal (Cohen's d = 0.66) than verbal learning (Cohen's d = 0.47) and semantic fluency (Cohen's d = 0.43). Individuals demonstrating an atypical pattern of performance on the CWIT inhibition/switching trial also demonstrated relative strengths in semantic fluency and learning.

  2. Whole body vibration improves cognition in healthy young adults.

    PubMed

    Regterschot, G Ruben H; Van Heuvelen, Marieke J G; Zeinstra, Edzard B; Fuermaier, Anselm B M; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van Der Zee, Eddy A

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5±2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on the Stroop Color-Block Test (CBT), Stroop Color-Word Interference Test (CWIT), Stroop Difference Score (SDS) and Digit Span Backward task (DSBT) was measured. In half of the passive WBV and control sessions the test order was CBT-CWIT-DSBT, and DSBT-CBT-CWIT in the other half. Passive WBV improved CWIT (p = 0.009; effect size r = 0.20) and SDS (p = 0.034; r = 0.16) performance, but only when the CBT and CWIT preceded the DSBT. CBT and DSBT performance did not change. This study shows that two minutes passive WBV has positive acute effects on attention and inhibition in young adults, notwithstanding their high cognitive functioning which could have hampered improvement. This finding indicates the potential of passive WBV as a cognition-enhancing therapy worth further evaluation, especially in persons unable to perform active forms of exercise.

  3. Association of parent-child relationships and executive functioning in South Asian adolescents.

    PubMed

    Fatima, Shameem; Sheikh, Hamid; Ardila, Alfredo

    2016-01-01

    It is known that some environmental variables can significantly affect the development of executive functions (EF). The primary aim of this study was to analyze whether some family conditions, such as the adolescent's perception of the quality of parent-child relationships and the socioeconomic status (SES; assessed according to education, occupational status, and income) are significantly associated with EF test scores. There were 370 Pakistani participants ranging in age 13 to 19 years who were selected and then individually administered the following tests taken from the Delis-Kaplan Executive Function System (D-KEFS): Trail Making Test (TMT), Design Fluency Test (DFT), Color Word Interference Test (CWIT), and Card Sorting Test (CST). In addition, a Parent-Child Relationship Scale (PCRS) also was administered. Results showed that perceived "neglect" in the PCRS was negatively associated with the 4 EF test scores. Parents' education and SES were positively associated with 3 EF measures: DFT, CWIT, and CST. Further correlational analyses revealed that inhibition (as measured with the CWIT) and problem-solving ability (as measured with the CST) were significantly associated with the perceived parent-child relationships. Some gender differences also were observed: males outperformed females on TMT, DFT, and CST, while females outperformed males in the CWIT. It was concluded that perceived parent-child relationships, SES, and parents' education are significantly associated with executive function test performance during adolescents. (c) 2015 APA, all rights reserved).

  4. Convergence and divergence of neuroanatomic correlates and executive task performance in healthy controls and psychiatric participants.

    PubMed

    Ming-Tak Chung, Dennis; Jerram, Matthew W; Lee, Jonathan K; Katz, Harvey; Gansler, David A

    2013-12-30

    The associations between brain matter volume in the cerebral cortex and set shifting and attentional control as operationalized by the Wisconsin Card Sort Test (WCST) and Condition Three of the Delis-Kaplan version of the Color Word Interference Test (CWIT) were investigated in 15 healthy controls and 16 heterogeneously diagnosed psychiatric patients with self-control problems using voxel based morphometry. Both groups underwent standardized magnetic resonance imaging and neuropsychological assessment. WCST and CWIT variables, and a composite, were regressed across the whole brain. Although CWIT performance levels were the same in both groups, neuroanatomic correlates for the psychiatric participants invoked the left hemisphere language system, but the bilateral dorsal attention system in the healthy controls. On its own, no neuroanatomic correlates were observed for the WCST. But when part of a composite with CWIT, neuroanatomic correlates in the dorsal attention system emerged for the psychiatric participants. Psychometric combinations of manifest executive task variables may best represent higher level latent neuro-cognitive control systems. Factor analytic studies of neuropsychological test performances suggest the constructs being measured are the same across psychiatric and non-diagnosed participants, however, imaging modalities indicate the relevant neural architecture can vary by group. © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Comparison between cold water immersion therapy (CWIT) and light emitting diode therapy (LEDT) in short-term skeletal muscle recovery after high-intensity exercise in athletes--preliminary results.

    PubMed

    Leal Junior, Ernesto Cesar; de Godoi, Vanessa; Mancalossi, José Luis; Rossi, Rafael Paolo; De Marchi, Thiago; Parente, Márcio; Grosselli, Douglas; Generosi, Rafael Abeche; Basso, Maira; Frigo, Lucio; Tomazoni, Shaiane Silva; Bjordal, Jan Magnus; Lopes-Martins, Rodrigo Alvaro Brandão

    2011-07-01

    In the last years, phototherapy has becoming a promising tool to improve skeletal muscle recovery after exercise, however, it was not compared with other modalities commonly used with this aim. In the present study we compared the short-term effects of cold water immersion therapy (CWIT) and light emitting diode therapy (LEDT) with placebo LEDT on biochemical markers related to skeletal muscle recovery after high-intensity exercise. A randomized double-blind placebo-controlled crossover trial was performed with six male young futsal athletes. They were treated with CWIT (5°C of temperature [SD ±1°]), active LEDT (69 LEDs with wavelengths 660/850 nm, 10/30 mW of output power, 30 s of irradiation time per point, and 41.7 J of total energy irradiated per point, total of ten points irradiated) or an identical placebo LEDT 5 min after each of three Wingate cycle tests. Pre-exercise, post-exercise, and post-treatment measurements were taken of blood lactate levels, creatine kinase (CK) activity, and C-reactive protein (CRP) levels. There were no significant differences in the work performed during the three Wingate tests (p > 0.05). All biochemical parameters increased from baseline values (p < 0.05) after the three exercise tests, but only active LEDT decreased blood lactate levels (p = 0.0065) and CK activity (p = 0.0044) significantly after treatment. There were no significant differences in CRP values after treatments. We concluded that treating the leg muscles with LEDT 5 min after the Wingate cycle test seemed to inhibit the expected post-exercise increase in blood lactate levels and CK activity. This suggests that LEDT has better potential than 5 min of CWIT for improving short-term post-exercise recovery.

  6. Estrogen Replacement Improves Verbal Memory and Executive Control in Oligomenorrheic/Amenorrheic Athletes in a Randomized Controlled Trial.

    PubMed

    Baskaran, Charumathi; Cunningham, Brooke; Plessow, Franziska; Singhal, Vibha; Woolley, Ryan; Ackerman, Kathryn E; Slattery, Meghan; Lee, Hang; Lawson, Elizabeth A; Eddy, Kamryn; Misra, Madhusmita

    2017-05-01

    Both estrogen and exercise may have cognition enhancing benefits; however, young oligomenorrheic/amenorrheic athletes (OA) with estrogen deficiency have not been evaluated for cognitive deficits. Our objective was to determine whether 6 months of estrogen replacement will impact cognitive domains in OA. We hypothesized that estrogen replacement would improve verbal memory and executive control in OA. We performed cognitive assessments at baseline and after 6 months in 48 OA (14-25 years) randomized to estrogen (EST+) (oral 30 µg ethinyl estradiol [n = 16] or transdermal 100 µg 17-β-estradiol patch [n = 13]) or no estrogen (EST-) (n = 19) in an ongoing clinical trial. Neurocognitive testing included California Verbal Learning Test-Second Edition (CVLT-II) (for verbal memory) and Delis-Kaplan Executive Function System Color-Word Interference Test (D-KEFS-CWIT) (executive control). On average, subjects (mean ± SEM age: 19.9 ± 3.1 years, body mass index: 20.6 ± 2.3 kg/m²) participated in 10.3 ± 5.9 hours per week of weight-bearing activities of their lower limbs. The EST+ group performed better for CVLT-II verbal memory scores for immediate recall over 6 months of therapy compared to EST- (P < .05) even after controlling for baseline scores and age. Changes in D-KEFS-CWIT scores over 6 months did not differ between the groups. However, the EST+ group had greater improvements in inhibition-switching completion time over 6 months compared with the EST- group after controlling for baseline scores and age (P = .01). OA show improvements in verbal memory and executive control following 6 months of estrogen replacement. These findings in athletes, who are in their prime of neurocognitive development, underscore the need for future studies exploring cognition in OA. ClinicalTrials.gov identifier: NCT00946192. © Copyright 2017 Physicians Postgraduate Press, Inc.

  7. Executive functions, parental punishment, and aggression: Direct and moderated relations.

    PubMed

    Fatima, Shameem; Sharif, Imran

    2017-12-01

    The main focus of the current study was to assess whether executive functions (EFs) moderate the effect of parental punishment on adolescent aggression. The sample were 370 participants (53% girls, 47% boys) enrolled at secondary and higher secondary levels and ranged in age between 13-19 years (M = 15.5, SD = 1.3). Participants were assessed on a self-report measure of aggression and two punishment measures, in addition to a demographic sheet. Then, they were individually assessed on four tests taken from the Delis-Kaplan Executive Functions System (D-KEFS) namely Trial Making Test (TMT), Design Fluency Test (DFT), Color Word Interference Test (CWIT), and Card Sorting Test (CST) to assess cognitive flexibility, nonverbal fluency, inhibition, and problem-solving ability, respectively. Correlation coefficients indicated that all four executive functioning measures and the two punishment measures were significantly correlated with aggression. Moderation analysis indicated that all EFs moderated the relationship between physical punishment and aggression, and only inhibition and problem-solving ability, but not cognitive flexibility and nonverbal fluency, moderated the relations between symbolic punishment and aggression. The findings support the hypothesis that EFs are protective personal factors that promote healthy adolescent adjustment in the presence of challenging environmental factors.

  8. Salient measures of inhibition and switching are associated with frontal lobe gray matter volume in healthy middle-aged and older adults.

    PubMed

    Adólfsdóttir, Steinunn; Haász, Judit; Wehling, Eike; Ystad, Martin; Lundervold, Arvid; Lundervold, Astri J

    2014-11-01

    To investigate brain-behavior relationships between morphometric brain measures and salient executive function (EF) measures of inhibition and switching. One hundred participants (49-80 years) performed the Color Word Interference Test from the Delis-Kaplan Executive Function System (D-KEFS). Salient measures of EF components of inhibition and switching, of which the effect of more fundamental skills were regressed out, were analyzed using linear models and a conditional inference trees analysis taking intercorrelations between predictor variables (brain volumes, age, gender, and education) into account. The conditional inference trees analysis demonstrated a primary role of the middle frontal gyrus (MFG) in explaining variations in the salient EF measure of switching and combined inhibition/switching. Age predicted measures of inhibition. The study highlights the importance of considering fundamental cognitive skills and the use of a statistical method taking possible complex relationships between predictor variables into account when interpreting standard EF test results. Further studies should include MRI measures representing neural networks that may relate to CWIT performance, and longitudinal studies are required to investigate any causal relationships. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. Microgravity heat pump for space station thermal management.

    PubMed

    Domitrovic, R E; Chen, F C; Mei, V C; Spezia, A L

    2003-01-01

    A highly efficient recuperative vapor compression heat pump was developed and tested for its ability to operate independent of orientation with respect to gravity while maximizing temperature lift. The objective of such a heat pump is to increase the temperature of, and thus reduce the size of, the radiative heat rejection panels on spacecrafts such as the International Space Station. Heat pump operation under microgravity was approximated by gravitational-independent experiments. Test evaluations include functionality, efficiency, and temperature lift. Commercially available components were used to minimize costs of new hardware development. Testing was completed on two heat pump design iterations--LBU-I and LBU--II, for a variety of operating conditions under the variation of several system parameters, including: orientation, evaporator water inlet temperature (EWIT), condenser water inlet temperature (CWIT), and compressor speed. The LBU-I system employed an ac motor, belt-driven scroll compressor, and tube-in-tube heat exchangers. The LBU-II system used a direct-drive AC motor compressor assembly and plate heat exchangers. The LBU-II system in general outperformed the LBU-I system on all accounts. Results are presented for all systems, showing particular attention to those states that perform with a COP of 4.5 +/- 10% and can maintain a temperature lift of 55 degrees F (30.6 degrees C) +/- 10%. A calculation of potential radiator area reduction shows that points with maximum temperature lift give the greatest potential for reduction, and that area reduction is a function of heat pump efficiency and a stronger function of temperature lift.

  10. 78 FR 26849 - Model Specifications for Breath Alcohol Ignition Interlock Devices (BAIIDs)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-08

    ...--Acetone Test 14--Emergency Override Test 15--Radiofrequency Interference/Electromagnetic Interference Test... requirements; temperature extreme testing; radio frequency interference (RFI) or electromagnetic interference...

  11. Quantifying Contextual Interference and Its Effect on Skill Transfer in Skilled Youth Tennis Players

    PubMed Central

    Buszard, Tim; Reid, Machar; Krause, Lyndon; Kovalchik, Stephanie; Farrow, Damian

    2017-01-01

    The contextual interference effect is a well-established motor learning phenomenon. Most of the contextual interference effect literature has addressed simple skills, while less is known about the role of contextual interference in complex sport skill practice, particularly with respect to skilled performers. The purpose of this study was to assess contextual interference when practicing the tennis serve. Study 1 evaluated tennis serve practice of nine skilled youth tennis players using a novel statistical metric developed specifically to measure between-skill and within-skill variability as sources of contextual interference. This metric highlighted that skilled tennis players typically engaged in serve practice that featured low contextual interference. In Study 2, 16 skilled youth tennis players participated in 10 practice sessions that aimed to improve serving “down the T.” Participants were stratified into a low contextual interference practice group (Low CI) and a moderate contextual interference practice group (Moderate CI). Pre- and post-tests were conducted 1 week before and 1 week after the practice period. Testing involved a skill test, which assessed serving performance in a closed setting, and a transfer test, which assessed serving performance in a match-play setting. No significant contextual interference differences were observed with respect to practice performance. However, analysis of pre- and post-test serve performance revealed significant Group × Time interactions. The Moderate CI group showed no change in serving performance (service displacement from the T) from pre- to post-test in the skill test, but did display improvements in the transfer test. Conversely, the Low CI group improved serving performance (service displacement from the T) in the skill test but not the transfer test. Results suggest that the typical contextual interference effect is less clear when practicing a complex motor skill, at least with the tennis serve skill evaluated here. We encourage researchers and applied sport scientists to use our statistical metric to measure contextual interference. PMID:29163306

  12. Reduced Interference from Memory Testing: A Postretrieval Monitoring Account

    ERIC Educational Resources Information Center

    Pierce, Benton H.; Gallo, David A.; McCain, Jason L.

    2017-01-01

    Initial learning can interfere with subsequent learning (proactive interference [PI]), but recent work indicates initial testing can reduce PI. Here, we tested 2 alternative hypotheses of this effect: Does testing reduce PI by constraining retrieval to the target list, or by facilitating a postretrieval monitoring process? Participants first…

  13. Electromagnetic interference with pacemakers caused by portable media players.

    PubMed

    Thaker, Jay P; Patel, Mehul B; Jongnarangsin, Krit; Liepa, Valdis V; Thakur, Ranjan K

    2008-04-01

    Electromagnetic fields generated by electrical devices may cause interference with permanent pacemakers. Media players are becoming a common mode of portable entertainment. The most common media players used worldwide are iPods. These devices are often carried in a shirt chest pocket, which may place the devices close to an implanted pacemaker. The purpose of this study was to determine if iPods cause interference with pacemakers. In this prospective, single-blinded study, 100 patients who had cardiac pacemakers were tested with four types of iPods to assess for interference. Patients were monitored by a single-channel ECG monitor as well as the respective pacemaker programmer via the telemetry wand. iPods were tested by placing them 2 inches anterior to the pacemaker and wand for up to 10 seconds. To simulate actual use, standard-issue headphones were plugged into the iPods. To maintain consistency, the volume was turned up maximally, and the equalizer was turned off. A subset of 25 patients underwent testing on 2 separate days to assess for reproducibility of interference. Pacemaker interference was categorized as type I or type II telemetry interference. Type I interference was associated with atrial and/or ventricular high rates on rate histograms. Type II interference did not affect pacemaker rate counters. Electromagnetic emissions from the four iPods also were evaluated in a Faraday cage to determine the mechanism of the observed interference. One hundred patients (63 men and 37 women; mean age 77.1 +/- 7.6 years) with 11 single-chamber pacemakers and 89 dual-chamber pacemakers underwent 800 tests. The incidence of any type of interference was 51% of patients and 20% of tests. Type I interference was seen in 19% of patients and type II in 32% of patients. Reproducibility testing confirmed that interference occurred regardless of pacing configuration (unipolar or bipolar), pacing mode (AAI, VVI, or DDD), and from one day to the next. Electromagnetic emissions testing from the iPods demonstrated maximum emissions in the pacemaker carrier frequency range when the iPod was turned "on" with the headphones attached. iPods placed within 2 inches of implanted pacemakers monitored via the telemetry wand can cause interference with pacemakers.

  14. Analytical and experimental investigation of fatigue in a sheet specimen with an interference-fit bolt

    NASA Technical Reports Server (NTRS)

    Crews, J. H., Jr.

    1975-01-01

    A fatigue analysis, based on finite-element calculations and fatigue tests, was conducted for an aluminum-alloy sheet specimen with a steel interference-fit bolt. The stress analysis of the region near the bolt hole showed that the beneficial effect of an interference-fit bolt can be interpreted as the combined result of two effects: (1) load transfer through the bolt and (2) the compressive interference stresses in the sheet. Results of the fatigue tests show that progressively higher interference levels produced longer fatigue lives. The tests also show that a high level of interference prevents fretting at the bolt-sheet interface and that interferences larger than this level produced little additional improvement in fatigue life.

  15. Computerized Testing Software for Assessing Interference Suppression in Children and Adults: The Bivalent Shape Task (BST)

    PubMed Central

    Mueller, Shane T.; Esposito, Alena G.

    2015-01-01

    We describe the Bivalent Shape Task (BST), software using the Psychology Experiment Building Language (PEBL), for testing of cognitive interference and the ability to suppress interference. The test is available via the GNU Public License, Version 3 (GPLv3), is freely modifiable, and has been tested on both children and adults and found to provide a simple and fast non-verbal measure of cognitive interference and suppression that requires no reading. PMID:26702358

  16. Description and evaluation of an interference assessment for a slotted-wall wind tunnel

    NASA Technical Reports Server (NTRS)

    Kemp, William B., Jr.

    1991-01-01

    A wind-tunnel interference assessment method applicable to test sections with discrete finite-length wall slots is described. The method is based on high order panel method technology and uses mixed boundary conditions to satisfy both the tunnel geometry and wall pressure distributions measured in the slotted-wall region. Both the test model and its sting support system are represented by distributed singularities. The method yields interference corrections to the model test data as well as surveys through the interference field at arbitrary locations. These results include the equivalent of tunnel Mach calibration, longitudinal pressure gradient, tunnel flow angularity, wall interference, and an inviscid form of sting interference. Alternative results which omit the direct contribution of the sting are also produced. The method was applied to the National Transonic Facility at NASA Langley Research Center for both tunnel calibration tests and tests of two models of subsonic transport configurations.

  17. Electromagnetic interference in electrical systems of motor vehicles

    NASA Astrophysics Data System (ADS)

    Dziubiński, M.; Drozd, A.; Adamiec, M.; Siemionek, E.

    2016-09-01

    Electronic ignition system affects the electronic equipment of the vehicle by electric and magnetic fields. The measurement of radio electromagnetic interference originating from the ignition system affecting the audiovisual test bench was carried out with a variable speed of the ignition system. The paper presents measurements of radio electromagnetic interference in automobiles. In order to determine the level of electromagnetic interference, the audiovisual test bench was equipped with a set of meters for power consumption and assessment of the level of electromagnetic interference. Measurements of the electromagnetic interference level within the audiovisual system were performed on an experimental test bench consisting of the ignition system, starting system and charging system with an alternator and regulator.

  18. Cellular telephone interference with medical equipment.

    PubMed

    Tri, Jeffrey L; Severson, Rodney P; Firl, Allen R; Hayes, David L; Abenstein, John P

    2005-10-01

    To assess the potential electromagnetic interference (EMI) effects that new or current-generation cellular telephones have on medical devices. For this study, performed at the Mayo Clinic in Rochester, Minn, between March 9, 2004, and April 24, 2004, we tested 16 different medical devices with 6 cellular telephones to assess the potential for EMI. Two of the medical devices were tested with both new and old interface modules. The 6 cellular telephones chosen represent the different cellular technology protocols in use: Code Division Multiple Access (2 models), Global System for Mobile communications, Integrated Digital Enhanced Network, Time Division Multiple Access, and analog. The cellular telephones were tested when operating at or near their maximum power output. The medical devices, connected to clinical simulators during testing, were monitored by observing the device displays and alarms. Of 510 tests performed, the incidence of clinically important interference was 1.2%; EMI was Induced in 108 tests (21.2%). Interference occurred in 7 (44%) of the 16 devices tested. Cellular telephones can interfere with medical equipment. Technology changes in both cellular telephones and medical equipment may continue to mitigate or may worsen clinically relevant interference. Compared with cellular telephones tested in previous studies, those currently in use must be closer to medical devices before any interference is noticed. However, periodic testing of cellular telephones to determine their effects on medical equipment will be required.

  19. Release from output interference in recognition memory: A test of the attention hypothesis.

    PubMed

    Criss, Amy H; Salomão, Cristina; Malmberg, Kenneth J; Aue, William; Kılıç, Aslı; Claridge, MarkAvery

    2018-05-01

    Retrieval results in both costs and benefits to episodic memory. Output interference (OI) refers to the finding that episodic memory accuracy decreases with increasing test trials. Release from OI is the restoration of original accuracy at some point during the test. For example, a release from OI in recognition memory testing occurs when the semantic similarity between stimuli decreases midway through testing, suggesting that item representations stored on early trials cause interference on tests occurring on later trials to the extent that the earlier items share features with the latter items. In two recognition memory experiments, we demonstrate release from OI for words and faces. We also test whether release from OI is the result of interference or is due to a boost in attention caused by reorienting to a novel stimulus type. A test for the foils presented during the initial test list supports the interference account of OI. Implications for models of memory are discussed.

  20. Tents and Shelters

    DTIC Science & Technology

    2010-07-15

    Electromagnetic Interference ( EMI ), Transportability, Environmental, Human Factors Engineering (HFE), Reliability, Availability and Maintainability (RAM), and...vehicles and trailers to store, protect, and secure equipment, tools, and other theft-prone items. CBCs are designed not to interfere with the carrier’s...Transportability Test Facility. d. Electromagnetic Interference ( EMI ) Test Facility. e. Areas capable of conducting Blackout, Sound, Sand and Dust tests

  1. How to Be Proactive About Interference: Lessons From Animal Memory

    PubMed Central

    Wright, Anthony A.; Katz, Jeffrey S.; Ma, Wei Ji

    2015-01-01

    Processes of proactive interference were explored using the pigeon as a model system of memory. This study shows that proactive interference extends back in time at least 16 trials (and as many minutes), revealing a continuum of interference and providing a framework for studying memory. Pigeons were tested in a delayed same/different task containing trial-unique pictures. On interference trials, sample pictures from previous trials reappeared as test pictures on different trials. Proactive-interference functions showed greatest interference from the most recent trial and with the longer of two delays (10 s vs. 1 s). These interference functions are accounted for by a time-estimation model based on signal detection theory. The model predicts that accuracy at test is determined solely by the ratio of the elapsed time since the offset of the current-trial sample to the elapsed time since the offset of the interfering sample. Implications for comparing memory of different species and different types of memory (e.g., familiarity vs. recollection) are discussed. PMID:22491142

  2. How to be proactive about interference: lessons from animal memory.

    PubMed

    Wright, Anthony A; Katz, Jeffrey S; Ma, Wei Ji

    2012-05-01

    Processes of proactive interference were explored using the pigeon as a model system of memory. This study shows that proactive interference extends back in time at least 16 trials (and as many minutes), revealing a continuum of interference and providing a framework for studying memory. Pigeons were tested in a delayed same/different task containing trial-unique pictures. On interference trials, sample pictures from previous trials reappeared as test pictures on different trials. Proactive-interference functions showed greatest interference from the most recent trial and with the longer of two delays (10 s vs. 1 s). These interference functions are accounted for by a time-estimation model based on signal detection theory. The model predicts that accuracy at test is determined solely by the ratio of the elapsed time since the offset of the current-trial sample to the elapsed time since the offset of the interfering sample. Implications for comparing memory of different species and different types of memory (e.g., familiarity vs. recollection) are discussed.

  3. Wind tunnel wall interference

    NASA Technical Reports Server (NTRS)

    Newman, Perry A.; Mineck, Raymond E.; Barnwell, Richard W.; Kemp, William B., Jr.

    1986-01-01

    About a decade ago, interest in alleviating wind tunnel wall interference was renewed by advances in computational aerodynamics, concepts of adaptive test section walls, and plans for high Reynolds number transonic test facilities. Selection of NASA Langley cryogenic concept for the National Transonic Facility (NTF) tended to focus the renewed wall interference efforts. A brief overview and current status of some Langley sponsored transonic wind tunnel wall interference research are presented. Included are continuing efforts in basic wall flow studies, wall interference assessment/correction procedures, and adaptive wall technology.

  4. Test techniques: A survey paper on cryogenic tunnels, adaptive wall test sections, and magnetic suspension and balance systems

    NASA Technical Reports Server (NTRS)

    Kilgore, Robert A.; Dress, David A.; Wolf, Stephen W. D.; Britcher, Colin P.

    1989-01-01

    The ability to get good experimental data in wind tunnels is often compromised by things seemingly beyond our control. Inadequate Reynolds number, wall interference, and support interference are three of the major problems in wind tunnel testing. Techniques for solving these problems are available. Cryogenic wind tunnels solve the problem of low Reynolds number. Adaptive wall test sections can go a long way toward eliminating wall interference. A magnetic suspension and balance system (MSBS) completely eliminates support interference. Cryogenic tunnels, adaptive wall test sections, and MSBS are surveyed. A brief historical overview is given and the present state of development and application in each area is described.

  5. Reducing Retroactive Interference through the Use of Different Encoding Techniques: An Exploration of Pre-Test/Post-Test Analyses

    ERIC Educational Resources Information Center

    Cumming, John M.; De Miranda, Michael A.

    2012-01-01

    Retroactive interference (RI) in list learning occurs when the learning of a second list of words interferes with the recall of the first learned list. Having the lists be thematically different can reduce retroactive interference within list learning; however, this study demonstrates how RI can be reduced when the lists contain similar words.…

  6. Second Language Interference during First Language Processing by Arabic–English Bilinguals

    PubMed Central

    Alsaigh, Tahani; Kennison, Shelia M.

    2017-01-01

    The research investigated whether a bilinguals’ second language (L2) is activated during a task involving only the first language (L1). We tested the hypothesis that the amount of L2 interference can vary across settings, with less interference occurring in testing locations where L2 is rarely used. In Experiment 1, we compared language processing for 50 Arabic–English bilinguals tested in Saudi Arabia and 49 Arabic–English tested in the United States. In the task, participants viewed a picture and judged whether a phoneme presented over headphones was part of the L1 picture name. The results showed no effect of testing location on processing. For both groups of bilinguals, we observed L2 interference in mean error rates, but not in mean response times. We also found evidence for L2 interference in correlational analyses between response times and (a) participants’ weekly L2 usage and (b) frequency of English picture names. A second experiment with 24 Arabic monolinguals supported the conclusion that the results with bilinguals were due to L2 interference. Implications for theories of bilingual memory are discussed. PMID:29163322

  7. Stroop interference associated with efficient reading fluency and prelexical orthographic processing.

    PubMed

    Mano, Quintino R; Williamson, Brady J; Pae, Hye K; Osmon, David C

    2016-01-01

    The Stroop Color-Word Test involves a dynamic interplay between reading and executive functioning that elicits intuitions of word reading automaticity. One such intuition is that strong reading skills (i.e., more automatized word reading) play a disruptive role within the test, contributing to Stroop interference. However, evidence has accumulated that challenges this intuition. The present study examined associations among Stroop interference, reading skills (i.e., isolated word identification, grapheme-to-phoneme mapping, phonemic awareness, reading fluency) measured on standardized tests, and orthographic skills measured on experimental computerized tasks. Among university students (N = 152), correlational analyses showed greater Stroop interference to be associated with (a) relatively low scores on all standardized reading tests, and (b) longer response latencies on orthographic tasks. Hierarchical regression demonstrated that reading fluency and prelexical orthographic processing predicted unique and significant variance in Stroop interference beyond baseline rapid naming. Results suggest that strong reading skills, including orthographic processing, play a supportive role in resolving Stroop interference.

  8. Getting more from visual working memory: Retro-cues enhance retrieval and protect from visual interference.

    PubMed

    Souza, Alessandra S; Rerko, Laura; Oberauer, Klaus

    2016-06-01

    Visual working memory (VWM) has a limited capacity. This limitation can be mitigated by the use of focused attention: if attention is drawn to the relevant working memory content before test, performance improves (the so-called retro-cue benefit). This study tests 2 explanations of the retro-cue benefit: (a) Focused attention protects memory representations from interference by visual input at test, and (b) focusing attention enhances retrieval. Across 6 experiments using color recognition and color reproduction tasks, we varied the amount of color interference at test, and the delay between a retrieval cue (i.e., the retro-cue) and the memory test. Retro-cue benefits were larger when the memory test introduced interfering visual stimuli, showing that the retro-cue effect is in part because of protection from visual interference. However, when visual interference was held constant, retro-cue benefits were still obtained whenever the retro-cue enabled retrieval of an object from VWM but delayed response selection. Our results show that accessible information in VWM might be lost in the processes of testing memory because of visual interference and incomplete retrieval. This is not an inevitable state of affairs, though: Focused attention can be used to get the most out of VWM. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Ascorbic acid interference in the measurement of serum biochemical parameters: in vivo and in vitro studies.

    PubMed

    Martinello, Flávia; da Silva, Edson Luiz

    2006-04-01

    To investigate the negative interference of ascorbic acid in serum biochemical tests in relation to the dose of vitamin C intake and to the time of blood collection. Healthy volunteers (n = 18) consumed daily doses of vitamin C (0.25-4.0 g) for 1 week and serum parameters were assayed prior to the experiment and on the eighth day of consumption. Blood samples were collected 4, 12 and 24 h after vitamin C intake. Serum levels of ascorbic acid increased significantly after vitamin C ingestion inhibiting urate and total bilirubin tests 4 and 12 h after intake (P < 0.01). A significant negative interference occurred up to 24 h after consumption of 4 g vitamin C for the urate test. In contrast, ingestion of vitamin C did not show interference in glucose, triglyceride and cholesterol tests. Addition of ascorbic acid to serum inhibited the urate test to a similar extent to that observed after vitamin C intake. However, after ingesting vitamin C, the interference for the bilirubin test was greater than that of the in vitro interference. Commonly taken doses of supplementary vitamin C interfered negatively with the serum urate test based on the Trinder method, and with bilirubin metabolism.

  10. Mechanism of ascorbic acid interference in biochemical tests that use peroxide and peroxidase to generate chromophore.

    PubMed

    Martinello, Flávia; Luiz da Silva, Edson

    2006-11-01

    Ascorbic acid interferes negatively in peroxidase-based tests (Trinder method). However, the precise mechanism remains unclear for tests that use peroxide, a phenolic compound and 4-aminophenazone (4-AP). We determined the chemical mechanism of this interference, by examining the effects of ascorbic acid in the reaction kinetics of the production and reduction of the oxidized chromophore in urate, cholesterol, triglyceride and glucose tests. Reaction of ascorbic acid with the Trinder method constituents was also verified. Ascorbic acid interfered stoichiometrically with all tests studied. However, it had two distinct effects on the reaction rate. In the urate test, ascorbic acid decreased the chromophore formation with no change in its production kinetics. In contrast, in cholesterol, triglyceride and glucose tests, an increase in the lag phase of color development occurred. Of all the Trinder constituents, only peroxide reverted the interference. In addition, ascorbic acid did not interfere with oxidase activity nor reduce significantly the chromophore formed. Peroxide depletion was the predominant chemical mechanism of ascorbic acid interference in the Trinder method with phenolics and 4-AP. Distinctive effects of ascorbic acid on the reaction kinetics of urate, cholesterol, glucose and triglyceride might be due to the rate of peroxide production by oxidases.

  11. D-METHIONINE REDUCES TOBRAMYCIN-INDUCED OTOTOXICITY WITHOUT ANTIMICROBIAL INTERFERENCE IN ANIMAL MODELS

    PubMed Central

    Fox, Daniel J.; Cooper, Morris D.; Speil, Cristian A.; Roberts, Melissa H.; Yanik, Susan C.; Meech, Robert P.; Hargrove, Tim L.; Verhulst, Steven J.; Rybak, Leonard P.; Campbell, Kathleen C. M.

    2015-01-01

    Background Tobramycin is a critical cystic fibrosis treatment however it causes ototoxicity. This study tested D-methionine protection from tobramycin-induced ototoxicity and potential antimicrobial interference. Methods Auditory brainstem responses (ABR) and outer hair cell (OHC) quantifications measured protection in guinea pigs treated with tobramycin and a range of D-methionine doses. In vitro antimicrobial interference studies tested inhibition and post antibiotic effect assays. In vivo antimicrobial interference studies tested normal and neutropenic E. coli murine survival and intraperitoneal lavage bacterial counts. Results D-methionine conferred significant ABR threshold shift reductions. OHC protection was less robust but significant at 20 kHz in the 420 mg/kg/day group. In vitro studies did not detect D-methionine-induced antimicrobial interference. In vivo studies did not detect D-methionine-induced interference in normal or neutropenic mice. Conclusions D-methionine protects from tobramycin-induced ototoxicity without antimicrobial interference. The study results suggest D-met as a potential otoprotectant from clinical tobramycin use in cystic fibrosis patients. PMID:26166286

  12. d-Methionine reduces tobramycin-induced ototoxicity without antimicrobial interference in animal models.

    PubMed

    Fox, Daniel J; Cooper, Morris D; Speil, Cristian A; Roberts, Melissa H; Yanik, Susan C; Meech, Robert P; Hargrove, Tim L; Verhulst, Steven J; Rybak, Leonard P; Campbell, Kathleen C M

    2016-07-01

    Tobramycin is a critical cystic fibrosis treatment however it causes ototoxicity. This study tested d-methionine protection from tobramycin-induced ototoxicity and potential antimicrobial interference. Auditory brainstem responses (ABRs) and outer hair cell (OHC) quantifications measured protection in guinea pigs treated with tobramycin and a range of d-methionine doses. In vitro antimicrobial interference studies tested inhibition and post antibiotic effect assays. In vivo antimicrobial interference studies tested normal and neutropenic Escherichia coli murine survival and intraperitoneal lavage bacterial counts. d-Methionine conferred significant ABR threshold shift reductions. OHC protection was less robust but significant at 20kHz in the 420mg/kg/day group. In vitro studies did not detect d-methionine-induced antimicrobial interference. In vivo studies did not detect d-methionine-induced interference in normal or neutropenic mice. d-Methionine protects from tobramycin-induced ototoxicity without antimicrobial interference. The study results suggest d-met as a potential otoprotectant from clinical tobramycin use in cystic fibrosis patients. Published by Elsevier B.V.

  13. 40 CFR Table B-3 to Subpart B of... - Interferent Test Concentration, Parts per Million

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... per Million B Table B-3 to Subpart B of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION..., Subpt. B, Table B-3 Table B-3 to Subpart B of Part 53—Interferent Test Concentration, Parts per Million Table B-3 to Subpart B of Part 53—Interferent Test Concentration,1 Parts per Million Pollutant Analyzer...

  14. 40 CFR Table B-3 to Subpart B of... - Interferent Test Concentration,1 Parts per Million

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Interferent Test Concentration,1 Parts per Million B Table B-3 to Subpart B of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION..., Subpt. B, Table B-3 Table B-3 to Subpart B of Part 53—Interferent Test Concentration,1 Parts per Million...

  15. Assessment and control of spacecraft electromagnetic interference

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Design criteria are presented to provide guidance in assessing electromagnetic interference from onboard sources and establishing requisite control in spacecraft design, development, and testing. A comprehensive state-of-the-art review is given which covers flight experience, sources and transmission of electromagnetic interference, susceptible equipment, design procedure, control techniques, and test methods.

  16. Capabilities of wind tunnels with two-adaptive walls to minimize boundary interference in 3-D model testing

    NASA Technical Reports Server (NTRS)

    Rebstock, Rainer; Lee, Edwin E., Jr.

    1989-01-01

    An initial wind tunnel test was made to validate a new wall adaptation method for 3-D models in test sections with two adaptive walls. First part of the adaptation strategy is an on-line assessment of wall interference at the model position. The wall induced blockage was very small at all test conditions. Lift interference occurred at higher angles of attack with the walls set aerodynamically straight. The adaptation of the top and bottom tunnel walls is aimed at achieving a correctable flow condition. The blockage was virtually zero throughout the wing planform after the wall adjustment. The lift curve measured with the walls adapted agreed very well with interference free data for Mach 0.7, regardless of the vertical position of the wing in the test section. The 2-D wall adaptation can significantly improve the correctability of 3-D model data. Nevertheless, residual spanwise variations of wall interference are inevitable.

  17. Space shuttle solid rocket booster sting interference wind tunnel test analysis

    NASA Technical Reports Server (NTRS)

    Conine, B.; Boyle, W.

    1981-01-01

    Wind tunnel test results from shuttle solid rocket booster (SRB) sting interference tests were evaluated, yielding the general influence of the sting on the normal force and pitching moment coefficients and the side force and yawing moment coefficients. The procedures developed to determine the sting interference, the development of the corrected aerodynamic data, and the development of a new SRB aerodynamic mathematical model are documented.

  18. Poor Stroop performances in 15-year-old dyslexic teenagers.

    PubMed

    Kapoula, Zoï; Lê, Thanh-Thuan; Bonnet, Audrey; Bourtoire, Pauline; Demule, Emilie; Fauvel, Caroline; Quilicci, Catherine; Yang, Qing

    2010-06-01

    The Stroop test enables interference between color naming and reading to be studied. Protopapas et al. (2007) reported more errors in an interference task and longer reaction times in 12.5-year-old dyslexics; also more Stroop interference with lower reading skills. The present study uses a version of the Stroop with four color cards and aims to test interference and flexibility in older dyslexic teenagers. The four cards are: color naming, reading, interference and flexibility. In the latter, subjects have to name the color of the word inhibiting reading except when the word is inside a box. This flexibility task enables the testing of the capacity for cognitive switching between tasks. Ten dyslexics (15.1 +/- 0.7 years old) and fourteen controls (14.3 +/- 1.6 years old) participated in the study. All performed the color naming, the reading, the interference and the flexibility tasks in the same order. Subsequently, they performed a sequence of 60 saccades left-right followed by the interference task. Generally, dyslexic teenagers behaved similarly to non-dyslexics as they showed fewer errors in reading and color than in the interference and flexibility tasks. However, they made more errors and needed more time to accomplish each task than non-dyslexics. The results suggest that the inhibitory and attention processes required by the Stroop test are dysfunctioning even in older dyslexics. In contrast, the study shows no evidence for particular difficulty in the flexibility task, which would constitute an argument against problems with mental switching. Following the execution of saccades, errors in the interference test were significantly reduced for dyslexics, while the time was reduced for both groups. The effects are attributed to visual attention training via saccades.

  19. Wind tunnel wall interference (January 1980 - May 1988): A selected, annotated bibliography

    NASA Technical Reports Server (NTRS)

    Tuttle, Marie H.; Cole, Karen L.

    1988-01-01

    This selected bibliography lists 423 entries on the subject of wall interference during testing in wind tunnels. It is the third in a series of bibliographies on the subject. The first, NASA TM-87639, August 1986, is concerned with the reduction of wall interference by the use of adaptive walls. The second, NASA TP-89066, December 1986, is on wall interference in V/STOL and high lift testing. This, the third in the series, covers the wall interference literature published during the period January 1980 through May 1988, generally excluding those topics covered in the first two parts.

  20. A two-dimensional adaptive-wall test section with ventilated walls in the Ames 2- by 2-foot transonic wind tunnel

    NASA Technical Reports Server (NTRS)

    Schairer, Edward T.; Lee, George; Mcdevitt, T. Kevin

    1989-01-01

    The first tests conducted in the adaptive-wall test section of the Ames Research Center's 2- by 2-Foot Transonic Wind Tunnel are described. A procedure was demonstrated for reducing wall interference in transonic flow past a two-dimensional airfoil by actively controlling flow through the slotted walls of the test section. Flow through the walls was controlled by adjusting pressures in compartments of plenums above and below the test section. Wall interference was assessed by measuring (with a laser velocimeter) velocity distributions along a contour surrounding the model, and then checking those measurements for their compatibility with free-air far-field boundary conditions. Plenum pressures for minimum wall interference were determined from empirical influence coefficients. An NACA 0012 airfoil was tested at angles of attach of 0 and 2, and at Mach numbers between 0.70 and 0.85. In all cases the wall-setting procedure greatly reduced wall interference. Wall interference, however, was never completely eliminated, primarily because the effect of plenum pressure changes on the velocities along the contour could not be accurately predicted.

  1. Event-based proactive interference in rhesus monkeys.

    PubMed

    Devkar, Deepna T; Wright, Anthony A

    2016-10-01

    Three rhesus monkeys (Macaca mulatta) were tested in a same/different memory task for proactive interference (PI) from prior trials. PI occurs when a previous sample stimulus appears as a test stimulus on a later trial, does not match the current sample stimulus, and the wrong response "same" is made. Trial-unique pictures (scenes, objects, animals, etc.) were used on most trials, except on trials where the test stimulus matched potentially interfering sample stimulus from a prior trial (1, 2, 4, 8, or 16 trials prior). Greater interference occurred when fewer trials separated interference and test. PI functions showed a continuum of interference. Delays between sample and test stimuli and intertrial intervals were manipulated to test how PI might vary as a function of elapsed time. Contrary to a similar study with pigeons, these time manipulations had no discernable effect on the monkey's PI, as shown by compete overlap of PI functions with no statistical differences or interactions. These results suggested that interference was strictly based upon the number of intervening events (trials with other pictures) without regard to elapsed time. The monkeys' apparent event-based interference was further supported by retesting with a novel set of 1,024 pictures. PI from novel pictures 1 or 2 trials prior was greater than from familiar pictures, a familiar set of 1,024 pictures. Moreover, when potentially interfering novel stimuli were 16 trials prior, performance accuracy was actually greater than accuracy on baseline trials (no interference), suggesting that remembering stimuli from 16 trials prior was a cue that this stimulus was not the sample stimulus on the current trial-a somewhat surprising conclusion particularly given monkeys.

  2. Limited electromagnetic interference testing of evidential breath testers

    DOT National Transportation Integrated Search

    1983-05-06

    This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...

  3. Subsonic sting interference on the aerodynamic characteristics of a family of slanted-base ogive-cylinders

    NASA Technical Reports Server (NTRS)

    Britcher, Colin P.; Alcorn, Charles W.; Kilgore, W. Allen

    1990-01-01

    Support interference free drag, lift, and pitching moment measurements on a range of slanted base ogive cylinders were made using the NASA Langley 13 inch magnetic suspension and balance system. Typical test Mach numbers were in the range 0.04 to 0.2. Drag results are shown to be in broad agreement with previous tests with this configuration. Measurements were repeated with a dummy sting support installed in the wind tunnel. Significant support interferences were found at all test conditions and are quantified. Further comparison is made between interference free base pressures, obtained using remote telemetry, and sting cavity pressures.

  4. Stroop Color-Word Interference Test: Normative data for Spanish-speaking pediatric population.

    PubMed

    Rivera, D; Morlett-Paredes, A; Peñalver Guia, A I; Irías Escher, M J; Soto-Añari, M; Aguayo Arelis, A; Rute-Pérez, S; Rodríguez-Lorenzana, A; Rodríguez-Agudelo, Y; Albaladejo-Blázquez, N; García de la Cadena, C; Ibáñez-Alfonso, J A; Rodriguez-Irizarry, W; García-Guerrero, C E; Delgado-Mejía, I D; Padilla-López, A; Vergara-Moragues, E; Barrios Nevado, M D; Saracostti Schwartzman, M; Arango-Lasprilla, J C

    2017-01-01

    To generate normative data for the Stroop Word-Color Interference test in Spanish-speaking pediatric populations. The sample consisted of 4,373 healthy children from nine countries in Latin America (Chile, Cuba, Ecuador, Guatemala, Honduras, Mexico, Paraguay, Peru, and Puerto Rico) and Spain. Each participant was administered the Stroop Word-Color Interference test as part of a larger neuropsychological battery. The Stroop Word, Stroop Color, Stroop Word-Color, and Stroop Interference scores were normed using multiple linear regressions and standard deviations of residual values. Age, age2, sex, and mean level of parental education (MLPE) were included as predictors in the analyses. The final multiple linear regression models showed main effects for age on all scores, except on Stroop Interference for Guatemala, such that scores increased linearly as a function of age. Age2 affected Stroop Word scores for all countries, Stroop Color scores for Ecuador, Mexico, Peru, and Spain; Stroop Word-Color scores for Ecuador, Mexico, and Paraguay; and Stroop Interference scores for Cuba, Guatemala, and Spain. MLPE affected Stroop Word scores for Chile, Mexico, and Puerto Rico; Stroop Color scores for Mexico, Puerto Rico, and Spain; Stroop Word-Color scores for Ecuador, Guatemala, Mexico, Puerto Rico and Spain; and Stroop-Interference scores for Ecuador, Mexico, and Spain. Sex affected Stroop Word scores for Spain, Stroop Color scores for Mexico, and Stroop Interference for Honduras. This is the largest Spanish-speaking pediatric normative study in the world, and it will allow neuropsychologists from these countries to have a more accurate approach to interpret the Stroop Word-Color Interference test in pediatric populations.

  5. Proactive Interference in Short-Term Recognition and Recall Memory

    ERIC Educational Resources Information Center

    Dillon, Richard F.; Petrusic, William M.

    1972-01-01

    Purpose of study was to (a) compare the rate of increase of proactive interference over the first few trials under recall and recognition memory test conditions, (2) determine the effects of two types of distractors on short-term recognition, and (3) test memory after proactive interference had reached a stable level under each of three test…

  6. An Environmental Sentinel Biomonitor System for Drinking Water Protection

    DTIC Science & Technology

    2008-12-01

    threat chemicals. Potential interferences include chemicals commonly used for drinking water disinfection (chlorine and chloramine ), byproducts of...range. Of the potential interferences tested, the ECIS test was affected only by the disinfectants chlorine and chloramine ; chlorine is typically...Industrial and Potential Interfering Chemicals Used to Evaluate ESB System Toxicity Sensors TICs Potential Interferences Acrylonitrile Chloramine

  7. The effect of wind tunnel wall interference on the performance of a fan-in-wing VTOL model

    NASA Technical Reports Server (NTRS)

    Heyson, H. H.

    1974-01-01

    A fan-in-wing model with a 1.07-meter span was tested in seven different test sections with cross-sectional areas ranging from 2.2 sq meters to 265 sq meters. The data from the different test sections are compared both with and without correction for wall interference. The results demonstrate that extreme care must be used in interpreting uncorrected VTOL data since the wall interference may be so large as to invalidate even trends in the data. The wall interference is particularly large at the tail, a result which is in agreement with recently published comparisons of flight and large scale wind tunnel data for a propeller-driven deflected-slipstream configuration. The data verify the wall-interference theory even under conditions of extreme interference. A method yields reasonable estimates for the onset of Rae's minimum-speed limit. The rules for choosing model sizes to produce negligible wall effects are considerably in error and permit the use of excessively large models.

  8. Inductive interference in rapid transit signaling systems. volume 2. suggested test procedures.

    DOT National Transportation Integrated Search

    1987-03-31

    These suggested test procedures have been prepared in order to develop standard methods of analysis and testing to quantify and resolve issues of electromagnetic compatibility in rail transit operations. Electromagnetic interference, generated by rai...

  9. Sodium interference in the determination of urinary aldosterone.

    PubMed

    Aldea, Marta Lucía; Barallat, Jaume; Martín, María Amparo; Rosas, Irene; Pastor, María Cruz; Granada, María Luisa

    2016-02-01

    Primary hyperaldosteronism (PHA) is one of the most common endocrine forms of secondary hypertension. Among the most used confirmatory tests for PHA is urinary aldosterone determination after oral sodium loading test. The primary aim of our study was to investigate if sodium concentrations interfere with urinary aldosterone in an automated competitive immunoassay (Liaison®) as well as to verify the manufacturer's specifications. 24-hr urine samples were collected and stored frozen until assayed. Two pools at low and high aldosterone concentrations were prepared. Verification of performance for precision was tested according to Clinical and Laboratory Standards Institute (CLSI) document EP15-A2 and interference with increasing concentrations of NaCl according to CLSI EP7-A2. The assay met the quality specifications according to optimal biological variation. Our results show that sodium concentrations up to 200mmol/L do not interfere on urinary aldosterone quantification, but sodium concentrations above 486mmol/L negatively interfere with the test. The Liaison® automated method is useful for aldosterone determination in the PHA confirmatory test, but interferences with NaCl may occur. It is therefore recommended to determine urinary NaCl before measuring urinary aldosterone to avoid falsely low results. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. Material-specific retroactive interference effects of the Wechsler Adult Intelligence Scale-Fourth Edition on the Wechsler Memory Scale-Fourth Edition in a nonclinical sample.

    PubMed

    Ingram, Nicolette S; Diakoumakos, Jessica V; Sinclair, Erin R; Crowe, Simon F

    2016-01-01

    This study investigated proactive and retroactive interference effects between the Wechsler Memory Scale-Fourth Edition (WMS-IV) using the flexible approach, and the Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV). One hundred and eighty nonclinical participants were assigned to a four (visual interference, verbal interference, visual and verbal interference, vs. no interference) by two (retroactive vs. proactive) between-subjects design. The administration order of the tests was counterbalanced (i.e., administration of the WAIS-IV prior to the WMS-IV, and the WAIS-IV administered during the delay interval of the WMS-IV). The WAIS-IV produced significant retroactive interference effects on the WMS-IV; however, no proactive interference effect was observed. The retroactive interference effect was dependent on material specificity. The results indicate that material presented within the delay of the WMS-IV can have a significant effect on subsequent delayed recall. Clinicians should carefully consider the effects associated with carry-over effects of these tests when using them in combination.

  11. Color-Object Interference: Further Tests of an Executive Control Account

    ERIC Educational Resources Information Center

    La Heij, Wido; Boelens, Harrie

    2011-01-01

    Young children are slower in naming the color of a meaningful picture than in naming the color of an abstract form (Stroop-like color-object interference). The current experiments tested an executive control account of this phenomenon. First, color-object interference was observed in 6- and 8-year-olds but not in 12- and 16-year-olds (Experiment…

  12. Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests.

    PubMed

    Ma, Z; Monk, T G; Goodnough, L T; McClellan, A; Gawryl, M; Clark, T; Moreira, P; Keipert, P E; Scott, M G

    1997-09-01

    Polymerized hemoglobin solutions (Hb-based oxygen carriers; HBOCs) and a second-generation perfluorocarbon (PFC) emulsion (Perflubron) are in clinical trials as temporary oxygen carriers ("blood substitutes"). Plasma and serum samples from patients receiving HBOCs look markedly red, whereas those from patients receiving PFC appear to be lipemic. Because hemolysis and lipemia are well-known interferents in many assays, we examined the effects of these substances on clinical chemistry, immunoassay, therapeutic drug, and coagulation tests. HBOC concentrations up to 50 g/L caused essentially no interference for Na, K, Cl, urea, total CO2, P, uric acid, Mg, creatinine, and glucose values determined by the Hitachi 747 or Vitros 750 analyzers (or both) or for immunoassays of lidocaine, N-acetylprocainamide, procainamide, digoxin, phenytoin, quinidine, or theophylline performed on the Abbott AxSym or TDx. Gentamycin and vancomycin assays on the AxSym exhibited a significant positive and negative interference, respectively. Immunoassays for TSH on the Abbott IMx and for troponin I on the Dade Stratus were unaffected by HBOC at this concentration. Tests for total protein, albumin, LDH, AST, ALT, GGT, amylase, lipase, and cholesterol were significantly affected to various extents at different HBOC concentrations on the Hitachi 747 and Vitros 750. The CK-MB assay on the Stratus exhibited a negative interference at 5 g/L HBOC. HBOC interference in coagulation tests was method-dependent-fibrometer-based methods on the BBL Fibro System were free from interference, but optical-based methods on the MLA 1000C exhibited interferences at 20 g/L HBOC. A 1:20 dilution of the PFC-based oxygen carrier (600 g/L) caused no interference on any of these chemistry or immunoassay tests except for amylase and ammonia on the Vitros 750 and plasma iron on the Hitachi 747.

  13. Validation of Blockage Interference Corrections in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Walker, Eric L.

    2007-01-01

    A validation test has recently been constructed for wall interference methods as applied to the National Transonic Facility (NTF). The goal of this study was to begin to address the uncertainty of wall-induced-blockage interference corrections, which will make it possible to address the overall quality of data generated by the facility. The validation test itself is not specific to any particular modeling. For this present effort, the Transonic Wall Interference Correction System (TWICS) as implemented at the NTF is the mathematical model being tested. TWICS uses linear, potential boundary conditions that must first be calibrated. These boundary conditions include three different classical, linear. homogeneous forms that have been historically used to approximate the physical behavior of longitudinally slotted test section walls. Results of the application of the calibrated wall boundary conditions are discussed in the context of the validation test.

  14. Changing room cues reduces the effects of proactive interference in Clark's Nutcrackers, Nucifraga columbiana.

    PubMed

    Lewis, Jody L; Kamil, Alan C; Webbink, Kate E

    2013-04-01

    To determine what factors are important for minimizing interference effects in spatial memory, Clark's Nutcrackers, Nucifraga columbiana were tested for their spatial memory for two serial lists of locations per day. In this experiment two unique landmark sets were either different between List 1 and List 2 or the same. We found that Nutcrackers were most susceptible to interference when the landmark sets were the same. This study suggests that repeatedly testing animal memory in the same room, with the same cues, can hamper recall due to interference.

  15. Long-term interference at the semantic level: Evidence from blocked-cyclic picture matching.

    PubMed

    Wei, Tao; Schnur, Tatiana T

    2016-01-01

    Processing semantically related stimuli creates interference across various domains of cognition, including language and memory. In this study, we identify the locus and mechanism of interference when retrieving meanings associated with words and pictures. Subjects matched a probe stimulus (e.g., cat) to its associated target picture (e.g., yarn) from an array of unrelated pictures. Across trials, probes were either semantically related or unrelated. To test the locus of interference, we presented probes as either words or pictures. If semantic interference occurs at the stage common to both tasks, that is, access to semantic representations, then interference should occur in both probe presentation modalities. Results showed clear semantic interference effects independent of presentation modality and lexical frequency, confirming a semantic locus of interference in comprehension. To test the mechanism of interference, we repeated trials across 4 presentation cycles and manipulated the number of unrelated intervening trials (zero vs. two). We found that semantic interference was additive across cycles and survived 2 intervening trials, demonstrating interference to be long-lasting as opposed to short-lived. However, interference was smaller with zero versus 2 intervening trials, which we interpret to suggest that short-lived facilitation counteracted the long-lived interference. We propose that retrieving meanings associated with words/pictures from the same semantic category yields both interference due to long-lasting changes in connection strength between semantic representations (i.e., incremental learning) and facilitation caused by short-lived residual activation. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  16. Widespread Nanoparticle-Assay Interference: Implications for Nanotoxicity Testing

    PubMed Central

    Ong, Kimberly J.; MacCormack, Tyson J.; Clark, Rhett J.; Ede, James D.; Ortega, Van A.; Felix, Lindsey C.; Dang, Michael K. M.; Ma, Guibin; Fenniri, Hicham; Veinot, Jonathan G. C.; Goss, Greg G.

    2014-01-01

    The evaluation of engineered nanomaterial safety has been hindered by conflicting reports demonstrating differential degrees of toxicity with the same nanoparticles. The unique properties of these materials increase the likelihood that they will interfere with analytical techniques, which may contribute to this phenomenon. We tested the potential for: 1) nanoparticle intrinsic fluorescence/absorbance, 2) interactions between nanoparticles and assay components, and 3) the effects of adding both nanoparticles and analytes to an assay, to interfere with the accurate assessment of toxicity. Silicon, cadmium selenide, titanium dioxide, and helical rosette nanotubes each affected at least one of the six assays tested, resulting in either substantial over- or under-estimations of toxicity. Simulation of realistic assay conditions revealed that interference could not be predicted solely by interactions between nanoparticles and assay components. Moreover, the nature and degree of interference cannot be predicted solely based on our current understanding of nanomaterial behaviour. A literature survey indicated that ca. 95% of papers from 2010 using biochemical techniques to assess nanotoxicity did not account for potential interference of nanoparticles, and this number had not substantially improved in 2012. We provide guidance on avoiding and/or controlling for such interference to improve the accuracy of nanotoxicity assessments. PMID:24618833

  17. Adaptive wall research with two- and three-dimensional models in low speed and transonic tunnels

    NASA Technical Reports Server (NTRS)

    Lewis, M. C.; Neal, G.; Goodyer, M. J.

    1988-01-01

    This paper summarises recent research at the University of Southampton into adaptive wall technology and outlines the direction of current efforts. The work is aimed at developing techniques for use in test sections where the top and bottom walls may be adjusted in single curvature. Wall streamlining eliminates, as far as experimentally possible, the top and bottom wall interference in low speed and transonic aerofoil testing. A streamlining technique has been developed for low speeds which allows the testing of swept wing panels in low interference environments. At higher speeds, a comparison of several two-dimensional transonic streamlining algorithms has been made and a technique for streamlining with a choked test section has also been developed. Three-dimensional work has mainly concentrated on tests of sidewall mounted half-wings and the development of the software packages required to assess interference and to adjust the flexible walls. It has been demonstrated that two-dimensional wall adaptation can significantly modify the level of wall interference around relatively large three-dimensional models. The residual interferences are small and are probably amenable to standard post-test correction methods. Tests on a calibrated wing-body model are planned in the near future to further validate the proposed streamlining technique.

  18. Apparent hyperthyroidism caused by biotin-like interference from IgM anti-streptavidin antibodies.

    PubMed

    Lam, Leo; Bagg, Warwick; Smith, Geoff; Chiu, Weldon; Middleditch, Martin James; Lim, Julie Ching-Hsia; Kyle, Campbell Vance

    2018-05-29

    Exclusion of analytical interference is important when there is discrepancy between clinical and laboratory findings. However, interferences on immunoassays are often mistaken as isolated laboratory artefacts. We characterized and report the mechanism of a rare cause of interference in two patients that caused erroneous thyroid function tests, and also affects many other biotin dependent immunoassays. Patient 1 was a 77 y female with worsening fatigue while taking carbimazole over several years. Her thyroid function tests however, were not suggestive of hypothyroidism. Patient 2 was a 25 y female also prescribed carbimazole for apparent primary hyperthyroidism. Despite an elevated FT4, the lowest TSH on record was 0.17mIU/L. In both cases, thyroid function tests performed by an alternative method were markedly different. Further characterization of both patients' serum demonstrated analytical interference on many immunoassays using the biotin-streptavidin interaction. Sandwich assays (e.g. TSH, FSH, TNT, beta-HCG) were falsely low, while competitive assays (e.g. FT4, FT3, TBII) were falsely high. Pre-incubation of serum with streptavidin microparticles removed the analytical interference, initially suggesting the cause of interference was biotin, however, neither patient had been taking biotin. Instead, a ~100kDa IgM immunoglobulin with high affinity to streptavidin was isolated from each patient's serum. The findings confirm IgM anti-streptavidin antibodies as the cause of analytical interference. We describe two patients with apparent hyperthyroidism as a result of analytical interference caused by IgM anti-streptavidin antibodies. Analytical interference identified on one immunoassay should raise the possibility of other affected results. Characterization of interference may help to identify other potentially affected immunoassays. In the case of anti-streptavidin antibodies, the pattern of interference mimics that due to biotin ingestion; however, the degree of interference varies between individual assays and between patients.

  19. 40 CFR 80.47 - Performance-based Analytical Test Method Approach.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... chemistry and statistics, or at least a bachelor's degree in chemical engineering, from an accredited... be compensated for any known chemical interferences using good laboratory practices. (3) The test... section, individual test results shall be compensated for any known chemical interferences using good...

  20. An Evaluation of the Eclox Chemiluminescence Test, Hach Pesticide/Nerve Agent Test Strips, and Agri-Screen Test Tickets

    DTIC Science & Technology

    2010-06-30

    Interference Testing Our testing shows that it is unlikely that the Eclox Chemiluminescence Test will respond to the common disinfectant chloramine ...common disinfectants (chlorine and chloramine ), cyanobacterial byproducts (geosmin and MIB) or water quality parameters (humic/fulvic acids or water...toxicity sensor testing Table 2-2: Interferences Test Chemicals Concentration (mg/L) Chlorine 10 Chloramines 10 Geosmin 0.0001 Methyl-isoborneol

  1. Wall interference tests of a CAST 10-2/DOA 2 airfoil in an adaptive-wall test section

    NASA Technical Reports Server (NTRS)

    Mineck, Raymond E.

    1987-01-01

    A wind-tunnel investigation of a CAST 10-2/DOA 2 airfoil model has been conducted in the adaptive-wall test section of the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT) and in the National Aeronautical Establishment High Reynolds Number Two-Dimensional Test Facility. The primary goal of the tests was to assess two different wall-interference correction techniques: adaptive test-section walls and classical analytical corrections. Tests were conducted over a Mach number range from 0.3 to 0.8 and over a chord Reynolds number range from 6 million to 70 million. The airfoil aerodynamic characteristics from the tests in the 0.3-m TCT have been corrected for wall interference by the movement of the adaptive walls. No additional corrections for any residual interference have been applied to the data, to allow comparison with the classically corrected data from the same model in the conventional National Aeronautical Establishment facility. The data are presented graphically in this report as integrated force-and-moment coefficients and chordwise pressure distributions.

  2. 40 CFR 1065.372 - NDUV analyzer HC and H2O interference verification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compensation algorithms that utilize measurements of other gases to meet this interference verification, simultaneously conduct such measurements to test the algorithms during the analyzer interference verification. (c...

  3. Compound simulator IR radiation characteristics test and calibration

    NASA Astrophysics Data System (ADS)

    Li, Yanhong; Zhang, Li; Li, Fan; Tian, Yi; Yang, Yang; Li, Zhuo; Shi, Rui

    2015-10-01

    The Hardware-in-the-loop simulation can establish the target/interference physical radiation and interception of product flight process in the testing room. In particular, the simulation of environment is more difficult for high radiation energy and complicated interference model. Here the development in IR scene generation produced by a fiber array imaging transducer with circumferential lamp spot sources is introduced. The IR simulation capability includes effective simulation of aircraft signatures and point-source IR countermeasures. Two point-sources as interference can move in two-dimension random directions. For simulation the process of interference release, the radiation and motion characteristic is tested. Through the zero calibration for optical axis of simulator, the radiation can be well projected to the product detector. The test and calibration results show the new type compound simulator can be used in the hardware-in-the-loop simulation trial.

  4. Testing complex animal cognition: Concept learning, proactive interference, and list memory.

    PubMed

    Wright, Anthony A

    2018-01-01

    This article describes an approach for assessing and comparing complex cognition in rhesus monkeys and pigeons by training them in a sequence of synergistic tasks, each yielding a whole function for enhanced comparisons. These species were trained in similar same/different tasks with expanding training sets (8, 16, 32, 64, 128 … 1024 pictures) followed by novel-stimulus transfer eventually resulting in full abstract-concept learning. Concept-learning functions revealed better rhesus transfer throughout and full concept learning at the 128 set, versus pigeons at the 256 set. They were then tested in delayed same/different tasks for proactive interference by inserting occasional tests within trial-unique sessions where the test stimulus matched a previous sample stimulus (1, 2, 4, 8, 16 trials prior). Proactive-interference functions revealed time-based interference for pigeons (1, 10 s delays), but event-based interference for rhesus (no effect of 1, 10, 20 s delays). They were then tested in list-memory tasks by expanding the sample to four samples in trial-unique sessions (minimizing proactive interference). The four-item, list-memory functions revealed strong recency memory at short delays, gradually changing to strong primacy memory at long delays over 30 s for rhesus, and 10 s for pigeons. Other species comparisons and future directions are discussed. © 2018 Society for the Experimental Analysis of Behavior.

  5. Traditional test administration and proactive interference undermine visual-spatial working memory performance in schizophrenia-spectrum disorders.

    PubMed

    Girard, Todd A; Wilkins, Leanne K; Lyons, Kathleen M; Yang, Lixia; Christensen, Bruce K

    2018-05-31

    Introduction Working-memory (WM) is a core cognitive deficit among individuals with Schizophrenia Spectrum Disorders (SSD). However, the underlying cognitive mechanisms of this deficit are less known. This study applies a modified version of the Corsi Block Test to investigate the role of proactive interference in visuospatial WM (VSWM) impairment in SSD. Methods Healthy and SSD participants completed a modified version of the Corsi Block Test involving both high (typical ascending set size from 4 to 7 items) and low (descending set size from 7 to 4 items) proactive interference conditions. Results The results confirmed that the SSD group performed worse overall relative to a healthy comparison group. More importantly, the SSD group demonstrated greater VSWM scores under low (Descending) versus high (Ascending) proactive interference; this pattern is opposite to that of healthy participants. Conclusions This differential pattern of performance supports that proactive interference associated with the traditional administration format contributes to VSWM impairment in SSD. Further research investigating associated neurocognitive mechanisms and the contribution of proactive interference across other domains of cognition in SSD is warranted.

  6. Direct observation of phase-sensitive Hong-Ou-Mandel interference

    NASA Astrophysics Data System (ADS)

    Marek, Petr; Zapletal, Petr; Filip, Radim; Hashimoto, Yosuke; Toyama, Takeshi; Yoshikawa, Jun-ichi; Makino, Kenzo; Furusawa, Akira

    2017-09-01

    The quality of individual photons and their ability to interfere are traditionally tested by measuring the Hong-Ou-Mandel photon bunching effect. However, this phase-insensitive measurement only tests the particle aspect of the quantum interference, leaving out the phase-sensitive aspects relevant for continuous-variable processing. To overcome these limitations we formulate a witness capable of recognizing both the indistinguishability of the single photons and their quality with regard to their continuous-variable utilization. We exploit the conditional nonclassical squeezing and show that it can reveal both the particle and the wave aspects of the quantum interference in a single set of direct measurements. We experimentally test the witness by applying it to a pair of independent single photons retrieved on demand.

  7. The Role of Test Expectancy in the Build-Up of Proactive Interference in Long-Term Memory

    ERIC Educational Resources Information Center

    Weinstein, Yana; Gilmore, Adrian W.; Szpunar, Karl K.; McDermott, Kathleen B.

    2014-01-01

    We examined the hypothesis that interpolated testing in a multiple list paradigm protects against proactive interference by sustaining test expectancy during encoding. In both experiments, recall on the last of 5 word lists was compared between 4 conditions: a tested group who had taken tests on all previous lists, an untested group who had not…

  8. Sleep can reduce proactive interference.

    PubMed

    Abel, Magdalena; Bäuml, Karl-Heinz T

    2014-01-01

    Sleep has repeatedly been connected to processes of memory consolidation. While extensive research indeed documents beneficial effects of sleep on memory, little is yet known about the role of sleep for interference effects in episodic memory. Although two prior studies reported sleep to reduce retroactive interference, no sleep effect has previously been found for proactive interference. Here we applied a study format differing from that employed by the prior studies to induce a high degree of proactive interference, and asked participants to encode a single list or two interfering lists of paired associates via pure study cycles. Testing occurred after 12 hours of diurnal wakefulness or nocturnal sleep. Consistent with the prior work, we found sleep in comparison to wake did not affect memory for the single list, but reduced retroactive interference. In addition we found sleep reduced proactive interference, and reduced retroactive and proactive interference to the same extent. The finding is consistent with the view that arising benefits of sleep are caused by the reactivation of memory contents during sleep, which has been suggested to strengthen and stabilise memories. Such stabilisation may make memories less susceptible to competition from interfering memories at test and thus reduce interference effects.

  9. Interference of GSM mobile phones with communication between Cardiac Rhythm Management devices and programmers: A combined in vivo and in vitro study.

    PubMed

    Huang, Dong; Dong, Zhi-Feng; Chen, Yan; Wang, Fa-Bin; Wei, Zhi; Zhao, Wen-Bin; Li, Shuai; Liu, Ming-Ya; Zhu, Wei; Wei, Meng; Li, Jing-Bo

    2015-07-01

    To investigate interference, and how to avoid it, by high-frequency electromagnetic fields (EMFs) of Global System for Mobile Communications (GSM) mobile phone with communication between cardiac rhythm management devices (CRMs) and programmers, a combined in vivo and in vitro testing was conducted. During in vivo testing, GSM mobile phones interfered with CRM-programmer communication in 33 of 65 subjects tested (50.8%). Losing ventricle sensing was representative in this study. In terms of clinical symptoms, only 4 subjects (0.6%) felt dizzy during testing. CRM-programmer communication recovered upon termination of mobile phone communication. During in vitro testing, electromagnetic interference by high-frequency (700-950 MHz) EMFs reproducibly occurred in duplicate testing in 18 of 20 CRMs (90%). During each interference, the pacing pulse signal on the programmer would suddenly disappear while the synchronous signal was normal on the amplifier-oscilloscope. Simulation analysis showed that interference by radiofrequency emitting devices with CRM-programmer communication may be attributed to factors including materials, excitation source distance, and implant depth. Results suggested that patients implanted with CRMs should not be restricted from using GSM mobile phones; however, CRMs should be kept away from high-frequency EMFs of GSM mobile phone during programming. © 2015 Wiley Periodicals, Inc.

  10. The Interference Effects on an Airfoil of a Flat Plate at Mid-span Position

    NASA Technical Reports Server (NTRS)

    Ward, Kenneth E

    1931-01-01

    This report gives the results of an investigation of the mutual interference of an airfoil and a flat plate inserted at mid-span position. The tests were conducted in the Variable-Density Wind Tunnel of the National Advisory Committee for Aeronautics at a high value of the Reynolds Number. The interference effects of this combination were found to be small. Supplementary tests indicated that the use of fillets decreases both the lift and drag slightly. A bibliography of publication dealing with interference between wings and bodies, and with the effects of cut-outs and fillets is included.

  11. Testing can counteract proactive interference by integrating competing information.

    PubMed

    Wahlheim, Christopher N

    2015-01-01

    Testing initially learned information before presenting new information has been shown to counteract the deleterious effects of proactive interference by segregating competing sources of information. The present experiments were conducted to demonstrate that testing can also have its effects in part by integrating competing information. Variations of classic A-B, A-D paired-associate learning paradigms were employed that included two lists of word pairs and a cued-recall test. Repeated pairs appeared in both lists (A-B, A-B), control pairs appeared in List 2 only (A-B, C-D), and changed pairs appeared with the same cue in both lists but with different responses (A-B, A-D). The critical manipulation was whether pairs were tested or restudied in an interpolated phase that occurred between Lists 1 and 2. On a final cued-recall test, participants recalled List 2 responses and then indicated when they recollected that responses had earlier changed between lists. The change recollection measure indexed the extent to which competing responses were integrated during List 2. Change was recollected more often for tested than for restudied pairs. Proactive facilitation was obtained in cued recall when change was recollected, whereas proactive interference was obtained when change was not recollected. These results provide evidence that testing counteracted proactive interference in part by making List 1 responses more accessible during List 2, thus promoting integration and increasing later recollection of change. These results have theoretical implications because they show that testing can counteract proactive interference by integrating or segregating competing information.

  12. Sources of Interference in Recognition Testing

    ERIC Educational Resources Information Center

    Annis, Jeffrey; Malmberg, Kenneth J.; Criss, Amy H.; Shiffrin, Richard M.

    2013-01-01

    Recognition memory accuracy is harmed by prior testing (a.k.a., output interference [OI]; Tulving & Arbuckle, 1966). In several experiments, we interpolated various tasks between recognition test trials. The stimuli and the tasks were more similar (lexical decision [LD] of words and nonwords) or less similar (gender identification of male and…

  13. Inductive Interference in Rapid Transit Signaling Systems. Volume 3. Data and Test Results.

    DOT National Transportation Integrated Search

    1986-11-01

    This report presents comparative inductive interference data obtained from four U.S. rapid transit systems employing chopper propulsion control, as part of the Rail Transit Electromagnetic Interference/Electromagnetic Compatibility program conducted ...

  14. Release from Proactive Interference: Insufficiency of an Attentional Account

    ERIC Educational Resources Information Center

    MacLeod, Colin M.

    1975-01-01

    If an attentional cue affects retroactive interference, perhaps a similar mechanism underlies release from proactive interference. This study tested this hypothesis by inserting an attentional cue before the final trial in Wickens' paradigm. (Author/RK)

  15. Shear wave speed recovery using moving interference patterns obtained in sonoelastography experiments.

    PubMed

    McLaughlin, Joyce; Renzi, Daniel; Parker, Kevin; Wu, Zhe

    2007-04-01

    Two new experiments were created to characterize the elasticity of soft tissue using sonoelastography. In both experiments the spectral variance image displayed on a GE LOGIC 700 ultrasound machine shows a moving interference pattern that travels at a very small fraction of the shear wave speed. The goal of this paper is to devise and test algorithms to calculate the speed of the moving interference pattern using the arrival times of these same patterns. A geometric optics expansion is used to obtain Eikonal equations relating the moving interference pattern arrival times to the moving interference pattern speed and then to the shear wave speed. A cross-correlation procedure is employed to find the arrival times; and an inverse Eikonal solver called the level curve method computes the speed of the interference pattern. The algorithm is tested on data from a phantom experiment performed at the University of Rochester Center for Biomedical Ultrasound.

  16. Interference effects on commonly used memory tasks.

    PubMed

    Brophy, Linda M; Jackson, Martin; Crowe, Simon F

    2009-02-01

    This paper reports two studies which investigated the effect of interference on delayed recall scores of the WMS-III and other commonly used memory measures. In Study 1, participants completed the immediate and delayed components of the WMS-III, with or without the introduction of conceptually similar memory tasks between the recall trials. In Study 2, this order of administration was reversed, with the WMS-III subtests used as the interference items. The results indicated that the introduction of interference items during the delay negatively affected delayed recall performance on almost all sub-tests. In addition, equal effects of proactive and retroactive interference were demonstrated. These findings raise concerns regarding the standardization process for memory tasks and highlight the need to consider interference effects in clinical practice, and stand as a caution in the use of memory-related materials during the delay interval in memory testing.

  17. Contextual interference effects on the acquisition of skill and strength of the bench press.

    PubMed

    Naimo, Marshall A; Zourdos, Michael C; Wilson, Jacob M; Kim, Jeong-Su; Ward, Emery G; Eccles, David W; Panton, Lynn B

    2013-06-01

    The purpose of this study was to investigate contextual interference effects on skill acquisition and strength gains during the learning of the bench press movement. Twenty-four healthy, college-aged males and females were stratified to control, high contextual interference (HCI), and low contextual interference (LCI) groups. Treatment groups were provided with written and visual instruction on proper bench press form and practiced the bench press and dart throwing for four weeks. Within each session, LCI performed all bench press sets before undertaking dart-throws. HCI undertook dart-throws immediately following each set of bench press. Control only did testing. Measurements, including one repetition maximum (1RM), checklist scores based on video recordings of participants' 1RM's, and dart-throw test scores were taken at pre-test, 1 week, 2 week, post-test, and retention test. Results were consistent with the basic premise of the contextual interference effect. LCI had significant improvements in percent 1RM and checklist scores during training, but were mostly absent after training (post-test and retention test). HCI had significant improvements in percent 1RM and checklist scores both during and after training. Thus, HCI may augment strength and movement skill on the bench press since proper technique is an important component of resistance exercise movements. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Event-related potential evidence for separable automatic and controlled retrieval processes in proactive interference.

    PubMed

    Bergström, Zara M; O'Connor, Richard J; Li, Martin K-H; Simons, Jon S

    2012-05-21

    Interference between competing memories is a major source of retrieval failure, yet, surprisingly little is known about how competitive memory activation arises in the brain. One possibility is that interference during episodic retrieval might be produced by relatively automatic conceptual priming mechanisms that are independent of strategic retrieval processes. Such priming-driven interference might occur when the competing memories have strong pre-existing associations to the retrieval cue. We used ERPs to measure the neural dynamics of retrieval competition, and investigated whether the ERP correlates of interference were affected by varying task demands for selective retrieval. Participants encoded cue words that were presented either two or four times, paired either with the same or different strongly associated words across repetitions. In a subsequent test, participants either selectively recalled each cue's most recent associate, or simply judged how many times a cue had been presented, without requiring selective recall. Interference effects on test performance were only seen in the recall task. In contrast, ERPs during test revealed an early posterior positivity for high interference items that was present in both retrieval tasks. This early ERP effect likely reflects a conceptual priming-related N400 reduction when many associations to a cue were pre-activated. A later parietal positivity resembling the ERP correlate of conscious recollection was found only in the recall task. The results suggest that early effects of proactive interference are relatively automatic and independent of intentional retrieval processes, consistent with suggestions that interference can arise through conceptual priming. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Comparison of Commercial Electromagnetic Interface Test Techniques to NASA Electromagnetic Interference Test Techniques

    NASA Astrophysics Data System (ADS)

    Smith, V.

    2000-11-01

    This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.

  20. Comparison of Commercial Electromagnetic Interface Test Techniques to NASA Electromagnetic Interference Test Techniques

    NASA Technical Reports Server (NTRS)

    Smith, V.; Minor, J. L. (Technical Monitor)

    2000-01-01

    This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.

  1. Comparison of a two-dimensional adaptive-wall technique with analytical wall interference correction techniques

    NASA Technical Reports Server (NTRS)

    Mineck, Raymond E.

    1992-01-01

    A two dimensional airfoil model was tested in the adaptive wall test section of the NASA Langley 0.3 meter Transonic Cryogenic Tunnel (TCT) and in the ventilated test section of the National Aeronautical Establishment Two Dimensional High Reynold Number Facility (HRNF). The primary goal of the tests was to compare different techniques (adaptive test section walls and classical, analytical corrections) to account for wall interference. Tests were conducted over a Mach number range from 0.3 to 0.8 at chord Reynolds numbers of 10 x 10(exp 6), 15 x 10(exp 6), and 20 x 10(exp 6). The angle of attack was varied from about 12 degrees up to stall. Movement of the top and bottom test section walls was used to account for the wall interference in the HRNF tests. The test results are in good agreement.

  2. Mobile communication devices causing interference in invasive and noninvasive ventilators.

    PubMed

    Dang, Bao P; Nel, Pierre R; Gjevre, John A

    2007-06-01

    The aim of this study was to assess if common mobile communication systems would cause significant interference on mechanical ventilation devices and at what distances would such interference occur. We tested all the invasive and noninvasive ventilatory devices used within our region. This consisted of 2 adult mechanical ventilators, 1 portable ventilator, 2 pediatric ventilators, and 2 noninvasive positive pressure ventilatory devices. We operated the mobile devices from the 2 cellular communication systems (digital) and 1 2-way radio system used in our province at varying distances from the ventilators and looked at any interference they created. We tested the 2-way radio system, which had a fixed operation power output of 3.0 watts, the Global Systems for Mobile Communication cellular system, which had a maximum power output of 2.0 watts and the Time Division Multiple Access cellular system, which had a maximum power output of 0.2 watts on our ventilators. The ventilators were ventilating a plastic lung at fixed settings. The mobile communication devices were tested at varying distances starting at zero meter from the ventilator and in all operation modes. The 2-way radio caused the most interference on some of the ventilators, but the maximum distance of interference was 1.0 m. The Global Systems for Mobile Communication system caused significant interference only at 0 m and minor interference at 0.5 m on only 1 ventilator. The Time Division Multiple Access system caused no interference at all. Significant interference consisted of a dramatic rise and fluctuation of the respiratory rate, pressure, and positive end-expiratory pressure of the ventilators with no normalization when the mobile device was removed. From our experiment on our ventilators with the communication systems used in our province, we conclude that mobile communication devices such as cellular phones and 2-way radios are safe and cause no interference unless operated at very close distances of less than 1 meter.

  3. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    PubMed

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future interference screw designs to improve the performance of implants. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. The color-word interference test and its relation to performance impairment under auditory distraction.

    DOT National Transportation Integrated Search

    1972-03-01

    The ability to resist distraction is an important requirement for air traffic controllers. The study examined the relationship between performance on the Stroop color-word interference test (a suggested measure of distraction susceptibility) and impa...

  5. Radiated interference in rapid transit systems. volume 2. suggested test procedures.

    DOT National Transportation Integrated Search

    1987-06-30

    The purpose of this report is to present a suggested test procedure for measuring the radiated electromagnetic interference (EMI) emanating from rail transit systems. This report points out that, unlike inductive and conductive EMI, radiated EMI has ...

  6. Identification of algae which interfere with the detection of Giardia cysts and Cryptosporidium oocysts and a method for alleviating this interference.

    PubMed Central

    Rodgers, M R; Flanigan, D J; Jakubowski, W

    1995-01-01

    Fifty-four algal species were tested for cross-reaction in the American Society for Testing and Materials Giardia/Cryptosporidium indirect immunofluorescence assay, and 24 showed some degree of fluorescence. Two species, Navicula minima and Synechococcus elongatus, exhibited a bright apple green fluorescence. The addition of goat serum to the assay mixture blocked the fluorescence of most nontarget organisms tested and also decreased the background fluorescence. Goat serum did not interfere with the fluorescence of Giardia cysts or Cryptosporidium oocysts or the identification of cyst and oocyst internal structures. PMID:7487013

  7. Wind tunnel wall interference in V/STOL and high lift testing: A selected, annotated bibliography

    NASA Technical Reports Server (NTRS)

    Tuttle, M. H.; Mineck, R. E.; Cole, K. L.

    1986-01-01

    This bibliography, with abstracts, consists of 260 citations of interest to persons involved in correcting aerodynamic data, from high lift or V/STOL type configurations, for the interference arising from the wind tunnel test section walls. It provides references which may be useful in correcting high lift data from wind tunnel to free air conditions. References are included which deal with the simulation of ground effect, since it could be viewed as having interference from three tunnel walls. The references could be used to design tests from the standpoint of model size and ground effect simulation, or to determine the available testing envelope with consideration of the problem of flow breakdown. The arrangement of the citations is chronological by date of publication in the case of reports or books, and by date of presentation in the case of papers. Included are some documents of historical interest in the development of high lift testing techniques and wall interference correction methods. Subject, corporate source, and author indices, by citation numbers, have been provided to assist the users. The appendix includes citations of some books and documents which may not deal directly with high lift or V/STOL wall interference, but include additional information which may be helpful.

  8. Testing can counteract proactive interference by integrating competing information

    PubMed Central

    Wahlheim, Christopher N.

    2015-01-01

    Testing initially learned information before presenting new information has been shown to counteract the deleterious effects of proactive interference by segregating competing sources of information. The present experiments were conducted to demonstrate that testing can also have its effects in part by integrating competing information. Variations of classic A–B, A–D paired-associate learning paradigms were employed that included two lists of word pairs and a cued-recall test. Repeated pairs appeared in both lists (A–B, A–B), control pairs appeared in List 2 only (A–B, C–D), and changed pairs appeared with the same cue in both lists but with different responses (A–B, A–D). The critical manipulation was whether pairs were tested or restudied in an interpolated phase that occurred between Lists 1 and 2. On a final cued-recall test, participants recalled List 2 responses and then indicated when they recollected that responses had earlier changed between lists. The change recollection measure indexed the extent to which competing responses were integrated during List 2. Change was recollected more often for tested than for restudied pairs. Proactive facilitation was obtained in cued recall when change was recollected, whereas proactive interference was obtained when change was not recollected. These results provide evidence that testing counteracted proactive interference in part by making List 1 responses more accessible during List 2, thus promoting integration and increasing later recollection of change. These results have theoretical implications because they show that testing can counteract proactive interference by integrating or segregating competing information. PMID:25120241

  9. Disentangling the causal relationships between work-home interference and employee health.

    PubMed

    van Hooff, Madelon L M; Geurts, Sabine A E; Taris, Toon W; Kompier, Michiel A J; Dikkers, Josje S E; Houtman, Irene L D; van den Heuvel, Floor M M

    2005-02-01

    The present study was designed to investigate the causal relationships between (time- and strain-based) work-home interference and employee health. The effort-recovery theory provided the theoretical basis for this study. Two-phase longitudinal data (with a 1-year time lag) were gathered from 730 Dutch police officers to test the following hypotheses with structural equation modeling: (i) work-home interference predicts health deterioration, (ii) health complaints precede increased levels of such interference, and (iii) both processes operate. The relationship between stable and changed levels of work-home interference across time and their relationships with the course of health were tested with a group-by-time analysis of variance. Four subgroups were created that differed in starting point and the development of work-home interference across time. The normal causal model, in which strain-based (but not time-based) work-home interference was longitudinally related to increased health complaints 1 year later, fit the data well and significantly better than the reversed causal model. Although the reciprocal model also provided a good fit, it was less parsimonious than the normal causal model. In addition, both an increment in (strain-based) work-home interference across time and a long-lasting experience of high (strain-based) work-home interference were associated with a deterioration in health. It was concluded that (strain-based) work-home interference acts as a precursor of health impairment and that different patterns of (strain-based) work-home interference across time are related to different health courses. Particularly long-term experience of (strain-based) work-home interference seems responsible for an accumulation of health complaints.

  10. 78 FR 35173 - Physical Medicine Devices; Reclassification of Stair-Climbing Wheelchairs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-12

    .... Electromagnetic interference: The device may interfere with the operation of other electrical devices or be... electromagnetic compatibility testing as well as characterization of speed/acceleration, battery longevity, and... electrical safety and electromagnetic compatibility of the device. Performance testing must demonstrate...

  11. Potential interference to GPS from UWB transmitters : phase II test results

    DOT National Transportation Integrated Search

    2001-03-16

    In 1999, the U.S. Department of Transportation (DOT") approached Stanford University to research the compatibility of UWB and GPS and to conduct tests to help quantify any interference problems. This is the second report from Stanford to the Departme...

  12. BIOTIN INTERFERENCE WITH ROUTINE CLINICAL IMMUNOASSAYS: UNDERSTAND THE CAUSES AND MITIGATE THE RISKS.

    PubMed

    Samarasinghe, Shanika; Meah, Farah; Singh, Vinita; Basit, Arshi; Emanuele, Nicholas; Emanuele, Mary Ann; Mazhari, Alaleh; Holmes, Earle W

    2017-08-01

    The objectives of this report are to review the mechanisms of biotin interference with streptavidin/biotin-based immunoassays, identify automated immunoassay systems vulnerable to biotin interference, describe how to estimate and minimize the risk of biotin interference in vulnerable assays, and review the literature pertaining to biotin interference in endocrine function tests. The data in the manufacturer's "Instructions for Use" for each of the methods utilized by seven immunoassay system were evaluated. We also conducted a systematic search of PubMed/MEDLINE for articles containing terms associated with biotin interference. Available original reports and case series were reviewed. Abstracts from recent scientific meetings were also identified and reviewed. The recent, marked, increase in the use of over-the-counter, high-dose biotin supplements has been accompanied by a steady increase in the number of reports of analytical interference by exogenous biotin in the immunoassays used to evaluate endocrine function. Since immunoassay methods of similar design are also used for the diagnosis and management of anemia, malignancies, autoimmune and infectious diseases, cardiac damage, etc., biotin-related analytical interference is a problem that touches every area of internal medicine. It is important for healthcare personnel to become more aware of immunoassay methods that are vulnerable to biotin interference and to consider biotin supplements as potential sources of falsely increased or decreased test results, especially in cases where a lab result does not correlate with the clinical scenario. FDA = U.S. Food & Drug Administration FT3 = free tri-iodothyronine FT4 = free thyroxine IFUs = instructions for use LH = luteinizing hormone PTH = parathyroid hormone SA/B = streptavidin/biotin TFT = thyroid function test TSH = thyroid-stimulating hormone.

  13. Wistar-Kyoto rats as an animal model of anxiety vulnerability: support for a hypervigilance hypothesis.

    PubMed

    McAuley, J D; Stewart, A L; Webber, E S; Cromwell, H C; Servatius, R J; Pang, K C H

    2009-12-01

    Inbred Wistar-Kyoto (WKY) rats have been proposed as a model of anxiety vulnerability as they display behavioral inhibition and a constellation of learning and reactivity abnormalities relative to outbred Sprague-Dawley (SD) rats. Together, the behaviors of the WKY rat suggest a hypervigilant state that may contribute to its anxiety vulnerability. To test this hypothesis, open-field behavior, acoustic startle, pre-pulse inhibition and timing behavior were assessed in WKY and Sprague-Dawley (SD) rats. Timing behavior was evaluated using a modified version of the peak-interval timing procedure. Training and testing of timing first occurred without audio-visual (AV) interference. Following this initial test, AV interference was included on some trials. Overall, WKY rats took much longer to leave the center of the arena, made fewer line crossings, and reared less, than did SD rats. WKY rats showed much greater startle responses to acoustic stimuli and significantly greater pre-pulse inhibition than did the SD rats. During timing conditions without AV interference, timing accuracy for both strains was similar; peak times for WKY and SD rats were not different. During interference conditions, however, the timing behavior of the two strains was very different. Whereas peak times for SD rats were similar between non-interference and interference conditions, peak times for WKY rats were shorter and response rates higher in interference conditions than in non-interference conditions. The enhanced acoustic startle response, greater prepulse inhibition and altered timing behavior with audio-visual interference supports a characterization of WKY strain as hypervigilant and provides further evidence for the use of the WKY strain as a model of anxiety vulnerability.

  14. Interference removals on Pd, Ru and Au with ICP-QQQ-MS in PGE RM

    NASA Astrophysics Data System (ADS)

    Nadeem Hussain Bokhari, Syed; Meisel, Thomas; Walkner, Christoph

    2015-04-01

    Gold and platinum group elements (PGE) are essential industrial precious metals with high world demand due to their unique properties. Struggle for natural exploration of PGE is on great pace and recycling from industrial wastes, electronics and catalytic convertor is on the rise for PGE supply chain. Along with these developments it is becoming more challenging for analytical chemists to determine gold and PGE out of complex matrix which causes severe interferences. The current state of art is online analysis coupled with chromatographic separation of interferences. The ICP-QQQ-MS Agilent 8800 has the capability of using multi tunes and mass shifts. We aim to remove interferences on Pd+ (for direct and isotope dilution analysis) Au+ and Ru+ in lieu of chemical separations. YO+, SrOH+, ZnAr+, NiAr+, ZrO+, CuAr+, MoO+ , Ru+and Cd+ are expected interferences on Pd+ while Au+ is interfered by TaO+, HfOH+, GdAr+ and 102Ru+ ,104Ru+ by 102Pd+ ,104Pd+ etc. Initial test were performed on pure solutions of 1mg/l (interfering elements): 1 ng/l (Pd, Ru & Au) respectively. The outcomes of initial tests were applied on PGE reference material (RM) WMG-1 and SARM-7 (digested with Na2O2 sintering). The results obtained show that YO+, SrOH+ interfere (104Pd,105Pd), 104 Ru+ on (104Pd), ZnAr+ has slight interference on (104Pd and106Pd), ZrO+, NiAr+, CuAr+ interferences are negligible, MoO+ has severe interference on (108Pd, 110Pd) and that Cd+ has severe isobaric interference on (106Pd,108Pd, 110Pd). These interference have been removed by formation of Pd(NH3)3+complex. The TaO+, HfOH+ and GdAr+ interferences on Au+ are best removed by formation of Au(NH3)+ and Au(NH3)2+ complexes. 102Pd+,104Pd+interference on 102Ru+ ,104Ru+ can be removed by formation of Ru(NH3)4+ and RuO+ compounds. The results obtained comply with certified values of RM. The developed method is being tested on low concentration PGE reference materials. References: Sugiyama, N. " Removal of complex spectral interferences on noble metal isotopes." Agilent 8800 ICP-QQQ Application Handbook, 2014, 42-46.

  15. Not all performance validity tests are created equal: The role of recollection and familiarity in the Test of Memory Malingering and Word Memory Test.

    PubMed

    Eglit, Graham M L; Lynch, Julie K; McCaffrey, Robert J

    2017-03-01

    The Test of Memory Malingering (TOMM) and the Word Memory Test (WMT) are both performance validity tests (PVTs) that use a two-alternative forced-choice (2AFC) recognition memory format. Several studies have reported that these tests are susceptible to cognitive impairment and that the WMT is more susceptible than the TOMM. The current study explored components of recognition memory (i.e., conscious recollection and familiarity) underlying the TOMM and WMT to identify factors that make them susceptible and resilient to cognitive impairment. Fifty-four nonclinical undergraduate research participants were administered the TOMM and WMT while providing introspective judgments about their recognition memory using the remember/know/guess procedure. In addition, half of participants were administered dual-task interference, a manipulation intended to reduce recollection, during these tests, while the other half completed these tests without interference. Standard cutoffs on the TOMM and WMT were explored, as well as alternative cutoffs based on TOMM Trial 1 scores. The WMT was more impacted by dual-task interference than standard TOMM cutoff trials, while alternative TOMM cutoff trials were equally impacted by dual-task interference relative to the WMT. Dual-task interference reduced recollection on these tests, but spared familiarity. Standard TOMM trials and the WMT were relatively comparable on levels of recollection, but familiarity contributed more to the TOMM than to the WMT. Alternative TOMM trials possessed lower familiarity and recollection than standard TOMM trials and lower recollection than the WMT. Reduced recollection places examinees at risk of failing the TOMM and WMT, while familiarity contributes to the relative resilience of the standard TOMM. Future development of 2AFC recognition memory PVTs should attempt to maximize the contribution of familiarity to their completion.

  16. A new method of evaluating the side wall interference effect on airfoil angle of attack by suction from the side walls

    NASA Technical Reports Server (NTRS)

    Sawada, H.; Sakakibara, S.; Sato, M.; Kanda, H.; Karasawa, T.

    1984-01-01

    A quantitative evaluation method of the suction effect from a suction plate on side walls is explained. It is found from wind tunnel tests that the wall interference is basically described by the summation form of wall interferences in the case of two dimensional flow and the interference of side walls.

  17. Determination of hydroxide and carbonate contents of alkaline electrolytes containing zinc

    NASA Technical Reports Server (NTRS)

    Otterson, D. A.

    1975-01-01

    A method to prevent zinc interference with the titration of OH- and CO3-2 ions in alkaline electrolytes with standard acid is presented. The Ba-EDTA complex was tested and shown to prevent zinc interference with acid-base titrations without introducing other types of interference. Theoretical considerations indicate that this method can be used to prevent interference by other metals.

  18. Matter-wave diffraction approaching limits predicted by Feynman path integrals for multipath interference

    NASA Astrophysics Data System (ADS)

    Barnea, A. Ronny; Cheshnovsky, Ori; Even, Uzi

    2018-02-01

    Interference experiments have been paramount in our understanding of quantum mechanics and are frequently the basis of testing the superposition principle in the framework of quantum theory. In recent years, several studies have challenged the nature of wave-function interference from the perspective of Born's rule—namely, the manifestation of so-called high-order interference terms in a superposition generated by diffraction of the wave functions. Here we present an experimental test of multipath interference in the diffraction of metastable helium atoms, with large-number counting statistics, comparable to photon-based experiments. We use a variation of the original triple-slit experiment and accurate single-event counting techniques to provide a new experimental bound of 2.9 ×10-5 on the statistical deviation from the commonly approximated null third-order interference term in Born's rule for matter waves. Our value is on the order of the maximal contribution predicted for multipath trajectories by Feynman path integrals.

  19. Interference Effects and Drag of Struts on a Monoplane Wing

    NASA Technical Reports Server (NTRS)

    Ward, Kenneth E

    1931-01-01

    Tests were conducted in the Variable Density Wind Tunnel of the NACA to determine the importance of the interference effects and drag of struts on a monoplane. Inclined struts were placed upon a Gottingen 387 airfoil in the lower surface positions and in two upper surface positions. Tests were made at values of Reynolds Number comparable with those obtained in flight. It was found that the interference drag of struts may be as great as the drag of the struts alone.

  20. Development and psychometric testing of an instrument designed to measure chronic pain in dogs with osteoarthritis

    PubMed Central

    Boston, Raymond C.; Coyne, James C.; Farrar, John T.

    2010-01-01

    Objective To develop and psychometrically test an owner self-administered questionnaire designed to assess severity and impact of chronic pain in dogs with osteoarthritis. Sample Population 70 owners of dogs with osteoarthritis and 50 owners of clinically normal dogs. Procedures Standard methods for the stepwise development and testing of instruments designed to assess subjective states were used. Items were generated through focus groups and an expert panel. Items were tested for readability and ambiguity, and poorly performing items were removed. The reduced set of items was subjected to factor analysis, reliability testing, and validity testing. Results Severity of pain and interference with function were 2 factors identified and named on the basis of the items contained in them. Cronbach’s α was 0.93 and 0.89, respectively, suggesting that the items in each factor could be assessed as a group to compute factor scores (ie, severity score and interference score). The test-retest analysis revealed κ values of 0.75 for the severity score and 0.81 for the interference score. Scores correlated moderately well (r = 0.51 and 0.50, respectively) with the overall quality-of-life (QOL) question, such that as severity and interference scores increased, QOL decreased. Clinically normal dogs had significantly lower severity and interference scores than dogs with osteoarthritis. Conclusions and Clinical Relevance A psychometrically sound instrument was developed. Responsiveness testing must be conducted to determine whether the questionnaire will be useful in reliably obtaining quantifiable assessments from owners regarding the severity and impact of chronic pain and its treatment on dogs with osteoarthritis. PMID:17542696

  1. Pain and Cognitive Function Among Older Adults Living in the Community

    PubMed Central

    van der Leeuw, Guusje; Eggermont, Laura H. P.; Shi, Ling; Milberg, William P.; Gross, Alden L.; Hausdorff, Jeffrey M.; Bean, Jonathan F.

    2016-01-01

    Background. Pain related to many age-related chronic conditions is a burdensome problem in elderly adults and may also interfere with cognitive functioning. The purpose of this study was to examine the cross-sectional relationship between measures of pain severity and pain interference and cognitive performance in community-living older adults. Methods. We studied 765 participants in the Maintenance of Balance Independent Living Intellect and Zest (MOBILIZE) Boston Study, a population-based study of persons aged 70 and older. Global pain severity and interference were measured using the Brief Pain Inventory subscales. The neuropsychological battery included measures of attentional capacity (Trail Making Test A, WORLD Test), executive function (Trail Making Test B and Delta, Clock-in-a-Box, Letter Fluency), memory (Hopkins Verbal Learning Test), and a global composite measure of cognitive function. Multivariable linear regression models were used to analyze the relationship between pain and cognitive functioning. Results. Elderly adults with more severe pain or more pain interference had poorer performance on memory tests and executive functioning compared to elders with none or less pain. Pain interference was also associated with impaired attentional capacity. Additional adjustment for chronic conditions, behaviors, and psychiatric medication resulted in attenuation of many of the observed associations. However, the association between pain interference and general cognitive function persisted. Conclusions. Our findings point to the need for further research to understand how chronic pain may contribute to decline in cognitive function and to determine strategies that may help in preventing or managing these potential consequences of pain on cognitive function in older adults. PMID:26433218

  2. NACA Transonic Wind-tunnel Test Sections

    NASA Technical Reports Server (NTRS)

    Wright, Ray H; Ward, Vernon G

    1955-01-01

    Report presents an approximate subsonic theory for the solid-blockage interference in circular wind tunnels with walls slotted in the direction of flow. This theory indicated the possibility of obtaining zero blockage interference. Tests in a circular slotted tunnel based on the theory confirmed the theoretical predictions.

  3. Test Results for Developing Revised LORAN-C Protection Criteria

    DOT National Transportation Integrated Search

    1985-11-01

    This report presents the results obtained from a series of tests and related analyses studying the effect of harmful RF interference on LORAN-C receivers. The effects of interference in the 70 to 130 kHz band on typical LORAN-C receivers were assesse...

  4. Subthreshold Depressive Symptoms have a Negative Impact on Cognitive Functioning in Middle-Aged and Older Males.

    PubMed

    Brevik, Erlend J; Eikeland, Rune A; Lundervold, Astri J

    2013-01-01

    Cognitive aging is associated with a decline on measures of fluid intelligence (gF), whereas crystallized intelligence (gC) tends to remain stable. In the present study we asked if depressive symptoms might contribute to explain the decline on gF in a sample of healthy middle-aged and older adults. The Norwegian sample included 83 females and 42 males (M = 60, SD = 7.9 years). gF was calculated from factor-analysis, including tests of matrix reasoning (WASI), memory function (CVLT-II), processing speed and executive function (CDT; CWIT). gC was derived from a Vocabulary subtest (WASI). Depressive symptoms were assessed by self-reports on Beck's Depression Index (BDI) and ranged from 0 to 21 (M = 6, SD = 4.5). Increased age was correlated with a decline on gF (r = -0.436, p  < 0.001), but not gC (r=-0.103, p = ns.). The BDI score in the whole sample was correlated with gF (r = -0.313, p < 0.001). A more detailed analysis showed that the BDI score correlated with measures of both gF and gC in males. The correlations were non-significant for females on all measures, with the exception of a measure of processing speed/executive function. A regression analysis including age and sex in the first step, showed that symptoms of depression significantly contributed to explain decline on gF, F(3, 124) = 16.653, p < 0.001, R? = 0.292, ΔR? = 0.054. The results showed that symptoms of depression were negatively correlated with cognitive functioning in males even when the symptom-level was below clinical threshold. This indicates that minimal symptoms of depression in older men are clinically relevant to address.

  5. CW Interference Effects on High Data Rate Transmission Through the ACTS Wideband Channel

    NASA Technical Reports Server (NTRS)

    Kerczewski, Robert J.; Ngo, Duc H.; Tran, Quang K.; Tran, Diepchi T.; Yu, John; Kachmar, Brian A.; Svoboda, James S.

    1996-01-01

    Satellite communications channels are susceptible to various sources of interference. Wideband channels have a proportionally greater probability of receiving interference than narrowband channels. NASA's Advanced Communications Technology Satellite (ACTS) includes a 900 MHz bandwidth hardlimiting transponder which has provided an opportunity for the study of interference effects of wideband channels. A series of interference tests using two independent ACTS ground terminals measured the effects of continuous-wave (CW) uplink interference on the bit-error rate of a 220 Mbps digitally modulated carrier. These results indicate the susceptibility of high data rate transmissions to CW interference and are compared to results obtained with a laboratory hardware-based system simulation and a computer simulation.

  6. Binaural Interference and the Effects of Age and Hearing Loss.

    PubMed

    Mussoi, Bruna S S; Bentler, Ruth A

    2017-01-01

    The existence of binaural interference, defined here as poorer speech recognition with both ears than with the better ear alone, is well documented. Studies have suggested that its prevalence may be higher in the elderly population. However, no study to date has explored binaural interference in groups of younger and older adults in conditions that favor binaural processing (i.e., in spatially separated noise). Also, the effects of hearing loss have not been studied. To examine binaural interference through speech perception tests, in groups of younger adults with normal hearing, older adults with normal hearing for their age, and older adults with hearing loss. A cross-sectional study. Thirty-three participants with symmetric thresholds were recruited from the University of Iowa community. Participants were grouped as follows: younger with normal hearing (18-28 yr, n = 12), older with normal hearing for their age (73-87 yr, n = 9), and older with hearing loss (78-94 yr, n = 12). Prior noise exposure was ruled out. The Connected Speech Test (CST) and Hearing in Noise Test (HINT) were administered to all participants bilaterally, and to each ear separately. Test materials were presented in the sound field with speech at 0° azimuth and the noise at 180°. The Dichotic Digits Test (DDT) was administered to all participants through earphones. Hearing aids were not used during testing. Group results were compared with repeated measures and one-way analysis of variances, as appropriate. Within-subject analyses using pre-established critical differences for each test were also performed. The HINT revealed no effect of condition (individual ear versus bilateral presentation) using group analysis, although within-subject analysis showed that 27% of the participants had binaural interference (18% had binaural advantage). On the CST, there was significant binaural advantage across all groups with group data analysis, as well as for 12% of the participants at each of the two signal-to-babble ratios (SBRs) tested. One participant had binaural interference at each SBR. Finally, on the DDT, a significant right-ear advantage was found with group data, and for at least some participants. Regarding age effects, more participants in the pooled elderly groups had binaural interference (33.3%) than in the younger group (16.7%), on the HINT. The presence of hearing loss yielded overall lower scores, but none of the comparisons between bilateral and unilateral performance were affected by hearing loss. Results of within-subject analyses on the HINT agree with previous findings of binaural interference in ≥17% of listeners. Across all groups, a significant right-ear advantage was also seen on the DDT. HINT results support the notion that the prevalence of binaural interference is likely higher in the elderly population. Hearing loss, however, did not affect the differences between bilateral and better unilateral scores. The possibility of binaural interference should be considered when fitting hearing aids to listeners with symmetric hearing loss. Comparing bilateral to unilateral (unaided) performance on tests such as the HINT may provide the clinician with objective data to support subjective preference for one hearing aid as opposed to two. American Academy of Audiology

  7. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference.

    PubMed

    García-González, Elena; Aramendía, Maite; Álvarez-Ballano, Diego; Trincado, Pablo; Rello, Luis

    2016-04-01

    Endogenous antibodies (EA) may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases) this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house 'nonsense' sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG) precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern.

  8. Analytical Work in Support of the Design and Operation of Two Dimensional Self Streamlining Test Sections

    NASA Technical Reports Server (NTRS)

    Judd, M.; Wolf, S. W. D.; Goodyer, M. J.

    1976-01-01

    A method has been developed for accurately computing the imaginary flow fields outside a flexible walled test section, applicable to lifting and non-lifting models. The tolerances in the setting of the flexible walls introduce only small levels of aerodynamic interference at the model. While it is not possible to apply corrections for the interference effects, they may be reduced by improving the setting accuracy of the portions of wall immediately above and below the model. Interference effects of the truncation of the length of the streamlined portion of a test section are brought to an acceptably small level by the use of a suitably long test section with the model placed centrally.

  9. Automatic Radiated Susceptibility Test System for Payload Equipment

    NASA Technical Reports Server (NTRS)

    Ngo, Hoai T.; Sturman, John C.; Sargent, Noel B.

    1995-01-01

    An automatic radiated susceptibility test system (ARSTS) was developed for NASA Lewis Research Center's Electro-magnetic Interference laboratory. According to MSFC-SPEC 521B, any electrical or electronic equipment that will be transported by the spacelab and space shuttle must be tested for susceptibility to electromagnetic interference. This state-of-the-art automatic test system performs necessary calculations; analyzes, processes, and records a great quantity of measured data; and monitors the equipment being tested in real-time and with minimal user intervention. ARSTS reduces costly test time, increases test accuracy, and provides reliable test results.

  10. Release from proactive interference in rat spatial working memory.

    PubMed

    Roberts, William A; MacDonald, Hayden; Brown, Lyn; Macpherson, Krista

    2017-09-01

    A three-phase procedure was used to produce proactive interference (PI) in one trial on an eight-arm radial maze. Rats were forced to enter four arms for reward on an initial interference phase, to then enter the four remaining arms on a target phase, and to then choose among all eight arms on a retention test, with only the arms not visited in the target phase containing reward. Control trials involved only the target phase and the retention test. Lower accuracy was found on PI trials than on control trials, but performance on PI trials significantly exceeded chance, showing some retention of target memories. Changes in temporal and reward variables between the interference, target, and retention test phases showed release from PI, but changes in context and pattern of arm entry did not. It is suggested that the release from PI paradigm can be used to understand spatial memory encoding in rats and other species.

  11. Direct Validation of the Wall Interference Correction System of the Ames 11-Foot Transonic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert; Boone, Alan R.

    2003-01-01

    Data from the test of a large semispan model was used to perform a direct validation of a wall interference correction system for a transonic slotted wall wind tunnel. At first, different sets of uncorrected aerodynamic coefficients were generated by physically changing the boundary condition of the test section walls. Then, wall interference corrections were computed and applied to all data points. Finally, an interpolation of the corrected aerodynamic coefficients was performed. This interpolation made sure that the corrected Mach number of a given run would be constant. Overall, the agreement between corresponding interpolated lift, drag, and pitching moment coefficient sets was very good. Buoyancy corrections were also investigated. These studies showed that the accuracy goal of one drag count may only be achieved if reliable estimates of the wall interference induced buoyancy correction are available during a test.

  12. Resolution of common dietary sugars from probe sugars for test of intestinal permeability using capillary column gas chromatography.

    PubMed

    Farhadi, Ashkan; Keshavarzian, Ali; Fields, Jeremy Z; Sheikh, Maliha; Banan, Ali

    2006-05-19

    The most widely accepted method for the evaluation of intestinal barrier integrity is the measurement of the permeation of sugar probes following an oral test dose of sugars. The most-widely used sugar probes are sucrose, lactulose, mannitol and sucralose. Measuring these sugars using a sensitive gas chromatographic (GC) method, we noticed interference on the area of the lactulose and mannitol peaks. We tested different sugars to detect the possible makeup of these interferences and finally detected that the lactose interferes with lactulose peak and fructose interferes with mannitol peak. On further developing of our method, we were able to reasonably separate these peaks using different columns and condition for our assay. Sample preparation was rapid and simple and included adding internal standard sugars, derivitization and silylation. We used two chromatographic methods. In the first method we used Megabore column and had a run time of 34 min. This resulted in partial separation of the peaks. In the second method we used thin capillary column and was able to reasonably separate the lactose and lactulose peaks and the mannitol and fructose peaks with run time of 22 min. The sugar probes including mannitol, sucrose, lactulose, sucralose, fructose and lactose were detected precisely, without interference. The assay was linear between lactulose concentrations of 0.5 and 40 g/L (r(2)=1.000, P<0.0001) and mannitol concentrations of 0.01 and 40 g/L (r(2)=1.000). The sensitivity of this method remained high using new column and assay condition. The minimum detectable concentration calculated for both methods was 0.5 mg/L for lactulose and 1 mg/L for mannitol. This is the first report of interference of commonly used sugars with test of intestinal permeability. These sugars are found in most of fruits and dairy products and could easily interfere with the result of permeability tests. Our new GC assay of urine sugar probes permits the simultaneous quantitation of sucralose, sucrose, mannitol and lactulose, without interference with lactose and fructose. This assay is a rapid, simple, sensitive and reproducible method to accurately measure intestinal permeability.

  13. The effect of electromagnetic interference from mobile communication on the performance of intensive care ventilators.

    PubMed

    Jones, R P; Conway, D H

    2005-08-01

    Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the ventilators tested. In a clinical setting, high-power-output devices such as a two-way radio may cause significant interference in ventilator function. Medium-power-output devices such as mobile phones may cause minor alarm triggers. Low-power-output devices such as Bluetooth appear to cause no interference with ventilator function.

  14. The Contextual Interference Effect in Applied Settings

    ERIC Educational Resources Information Center

    Barreiros, Joao; Figueiredo, Teresa; Godinho, Mario

    2007-01-01

    This paper analyses the research literature that approaches the contextual interference effect in applied settings. In contrast to the laboratory settings, in which high interference conditions depress acquisition and promote learning evaluated in retention and transfer tests, in applied settings most of the studies (60%) fail to observe positive…

  15. The dual effect of context on memory of related and unrelated themes: discrimination at encoding and cue at retrieval.

    PubMed

    Levy-Gigi, Einat; Vakil, Eli

    2012-01-01

    The influence of contextual factors on encoding and retrieval in recognition memory was investigated using a retroactive interference paradigm. Participants were randomly assigned to four context conditions constructed by manipulating types of presentation modality (pictures vs words) for study, interference, and test stages, respectively (ABA, ABB, AAA, & AAB). In Experiment 1 we presented unrelated items in the study and interference stages, while in Experiment 2 each stage contained items from the same semantic category. The results demonstrate a dual role for context in memory processes-at encoding as well as at retrieval. In Experiment 1 there is a hierarchical order between the four context conditions, depending on both target-test and target-interference contextual similarity. Adding a categorical context in Experiment 2 helped to specify each list and therefore better distinguish between target and interferer information, and in some conditions compensated for their perceptual similarity.

  16. Single- and dual-carrier microwave noise abatement in the deep space network. [microwave antennas

    NASA Technical Reports Server (NTRS)

    Bathker, D. A.; Brown, D. W.; Petty, S. M.

    1975-01-01

    The NASA/JPL Deep Space Network (DSN) microwave ground antenna systems are presented which simultaneously uplink very high power S-band signals while receiving very low level S- and X-band downlinks. Tertiary mechanisms associated with elements give rise to self-interference in the forms of broadband noise burst and coherent intermodulation products. A long-term program to reduce or eliminate both forms of interference is described in detail. Two DSN antennas were subjected to extensive interference testing and practical cleanup program; the initial performance, modification details, and final performance achieved at several planned stages are discussed. Test equipment and field procedures found useful in locating interference sources are discussed. Practices deemed necessary for interference-free operations in the DSN are described. Much of the specific information given is expected to be easily generalized for application in a variety of similar installations. Recommendations for future investigations and individual element design are given.

  17. Viking telecommunication effects of GEOS satellite interference based on testing at the Madrid deep space station

    NASA Technical Reports Server (NTRS)

    Stuhr, F. V.; Kent, S. S.; Galvez, J. L.; Luaces, B. G.; Pasero, G. R.; Urech, J. M.

    1976-01-01

    In support of the ongoing NASA-European Space Agency (ESA) effort to understand and control possible interference between missions, testing was conducted at the Madrid Deep Space Station from July 1975 to February 1976 to characterize the effect on Viking 1975 telecommunication link performance of Geodetic Earth-Orbiting Satellite (GEOS) downlink signals. The prime use of the data was to develop a capability to predict GEOS interference effects for evaluation of Viking 1975 mission impacts and possible temporary GEOS shutdown. Also, the data would serve as a basis for assessment of the GEOS impact on missions other than Viking as well as for more general interference applications. Performances of the reference receiver, telemetry, and planetary ranging were measured in the presence of various types of GEOS-related interference, including an unmodulated GEOS carrier and simulation of the actual spectrum by an ESA-supplied GEOS suitcase model.

  18. A dedicated system for topographical working memory: evidence from domain-specific interference tests.

    PubMed

    Piccardi, L; Nori, R; Boccia, M; Barbetti, S; Verde, P; Guariglia, C; Ferlazzo, F

    2015-08-01

    In the present study, we used single- and dual-task conditions to investigate the nature of topographical working memory to better understand what type of task can hamper performance during navigation. During dual-task conditions, we considered four different sources of interference: motor (M), spatial motor (SM), verbal (i.e. articulatory suppression AS) and spatial environmental (SE). In order to assess the nature of topographical working memory, we used the Walking Corsi Test, asking the participants to perform two tasks simultaneously (M, SM, AS and SE). Our results showed that only spatial-environmental interference hampers the execution of a topographical working memory task, suggesting a task-domain-specific effect. We also found general gender differences in the topographical working memory capabilities: men were more proficient than women, regardless of the type of interferences. However, like men, women performed worse when a spatial-environmental interference was present.

  19. Factitious Graves' Disease Due to Biotin Immunoassay Interference-A Case and Review of the Literature.

    PubMed

    Elston, Marianne S; Sehgal, Shekhar; Du Toit, Stephen; Yarndley, Tania; Conaglen, John V

    2016-09-01

    Biotin (vitamin B7) is an essential co-factor for four carboxylases involved in fatty acid metabolism, leucine degradation, and gluconeogenesis. The recommended daily intake (RDI) of biotin is approximately 30 μg per day. Low-moderate dose biotin is a common component of multivitamin preparations, and high-dose biotin (10 000 times RDI) has been reported to improve clinical outcomes and quality of life in patients with progressive multiple sclerosis. Biotin is also a component of immunoassays, and supplementation may cause interference in both thyroid and non-thyroid immunoassays. To assess whether biotin ingestion caused abnormal thyroid function tests (TFTs) in a patient through assay interference. We report a patient with biotin-associated abnormal TFTs and a systematic review of the literature. A tertiary endocrine service in Hamilton, New Zealand. The patient had markedly abnormal TFTs that did not match the clinical context. After biotin cessation, TFTs normalized far more rapidly than possible given the half-life of T4, consistent with assay interference by biotin. Multiple other analytes also tested abnormal in the presence of biotin. Biotin ingested in moderate to high doses can cause immunoassay interference. Depending on the assay format, biotin interference can result in either falsely high or low values. Interference is not limited to thyroid tests and has the potential to affect a wide range of analytes. It is important for clinicians to be aware of this interaction to prevent misdiagnosis and inappropriate treatment.

  20. THE IDENTIFICATION OF ALGAE WHICH INTERFERE WITH THE DETECTION OF GIARDIA AND CRYPTOSPORIDIUM AND A METHOD FOR ALLEVIATING THIS INTERFERENCE

    EPA Science Inventory

    Fifty-four algal species were tested for cross-reaction in the American Society for Testing and Materials Giardia/Cryptosporidium indirect immunofluorescence assay, and 24 showed some degree of fluorescence. Two species, Navicula minima and Synechococcus elongatus, exhibited a b...

  1. PNTAB view : minimum criteria for testing/evaluation of interference potential of high power terrestrial transmitters in repurposed radio bands.

    DOT National Transportation Integrated Search

    2017-03-30

    Brief, 6-point set of guidelines that describe how to test the interference potential of high power terrestrial transmitters in repurposed radio bands. Presented at Global Positioning System Adjacent Band Compatibility Assessment Workshop VI, 03/30/2...

  2. Interference of Wing and Fuselage from Tests of 209 Combinations in the NACA Variable-Density Tunnel

    NASA Technical Reports Server (NTRS)

    Jacobs, Eastman N; Ward, Kenneth E

    1936-01-01

    This report presents the results of tests of 209 simple wing-fuselage combinations made in the NACA variable-density wind tunnel to provide information regarding the effects of aerodynamic interference between wings and fuselages at a large value of Reynolds number.

  3. Individual Differences in Digit Span, Susceptibility to Proactive Interference, and Aptitude/Achievement Test Scores.

    ERIC Educational Resources Information Center

    Dempster, Frank N.; Cooney, John B.

    1982-01-01

    Individual differences in digit span, susceptibility to proactive interference, and various aptitude/achievement test scores were investigated in two experiments with college students. Results indicated that digit span was strongly correlated with aptitude/achievement scores, but did not indicate that susceptibility to proactive interference…

  4. Torsional stability of interference screws derived from bovine bone - a biomechanical study

    PubMed Central

    2010-01-01

    Background In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. Methods In the first part of the study we compared the torsional stability of self-made 8 mm Interference screws (BC) and a commercial 8 mm interference screw (Tutofix®). Furthermore, we compared the torsional strength of BC screws with different diameters. For screwing in, a hexagon head and an octagon head were tested. Maximum breaking torques in polymethyl methacrylate resin were recorded by means of an electronic torque screw driver. In the second part of the study the tibial part of a bone-patellar tendon-bone graft was fixed in porcine test specimens using an 8 mm BC screw and the maximum insertion torques were recorded. Each interference screw type was tested 5 times. Results There was no statistically significant difference between the different 8 mm interference screws (p = 0.121). Pairwise comparisons did not reveal statistically significant differences, either. It was demonstrated for the BC screws, that a larger screw diameter significantly leads to higher torsional stability (p = 9.779 × 10-5). Pairwise comparisons showed a significantly lower torsional stability for the 7 mm BC screw than for the 8 mm BC screw (p = 0.0079) and the 9 mm BC screw (p = 0.0079). Statistically significant differences between the 8 mm and the 9 mm BC screw could not be found (p = 0.15). During screwing into the tibial graft channel of the porcine specimens, insertion torques between 0.5 Nm and 3.2 Nm were recorded. In one case the hexagon head of a BC screw broke off during the last turn. Conclusions The BC screws show comparable torsional stability to Tutofix® interference screws. As expected the torsional strength of the screws increases significantly with the diameter. The safety and in vivo performance of products derived from xenogeneic bone should be the focus of further investigations. PMID:20433761

  5. The Real-Time Wall Interference Correction System of the NASA Ames 12-Foot Pressure Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Ulbrich, Norbert

    1998-01-01

    An improved version of the Wall Signature Method was developed to compute wall interference effects in three-dimensional subsonic wind tunnel testing of aircraft models in real-time. The method may be applied to a full-span or a semispan model. A simplified singularity representation of the aircraft model is used. Fuselage, support system, propulsion simulator, and separation wake volume blockage effects are represented by point sources and sinks. Lifting effects are represented by semi-infinite line doublets. The singularity representation of the test article is combined with the measurement of wind tunnel test reference conditions, wall pressure, lift force, thrust force, pitching moment, rolling moment, and pre-computed solutions of the subsonic potential equation to determine first order wall interference corrections. Second order wall interference corrections for pitching and rolling moment coefficient are also determined. A new procedure is presented that estimates a rolling moment coefficient correction for wings with non-symmetric lift distribution. Experimental data obtained during the calibration of the Ames Bipod model support system and during tests of two semispan models mounted on an image plane in the NASA Ames 12 ft. Pressure Wind Tunnel are used to demonstrate the application of the wall interference correction method.

  6. Use of the Ames Check Standard Model for the Validation of Wall Interference Corrections

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Amaya, M.; Flach, R.

    2018-01-01

    The new check standard model of the NASA Ames 11-ft Transonic Wind Tunnel was chosen for a future validation of the facility's wall interference correction system. The chosen validation approach takes advantage of the fact that test conditions experienced by a large model in the slotted part of the tunnel's test section will change significantly if a subset of the slots is temporarily sealed. Therefore, the model's aerodynamic coefficients have to be recorded, corrected, and compared for two different test section configurations in order to perform the validation. Test section configurations with highly accurate Mach number and dynamic pressure calibrations were selected for the validation. First, the model is tested with all test section slots in open configuration while keeping the model's center of rotation on the tunnel centerline. In the next step, slots on the test section floor are sealed and the model is moved to a new center of rotation that is 33 inches below the tunnel centerline. Then, the original angle of attack sweeps are repeated. Afterwards, wall interference corrections are applied to both test data sets and response surface models of the resulting aerodynamic coefficients in interference-free flow are generated. Finally, the response surface models are used to predict the aerodynamic coefficients for a family of angles of attack while keeping dynamic pressure, Mach number, and Reynolds number constant. The validation is considered successful if the corrected aerodynamic coefficients obtained from the related response surface model pair show good agreement. Residual differences between the corrected coefficient sets will be analyzed as well because they are an indicator of the overall accuracy of the facility's wall interference correction process.

  7. Effect of occlusal interference on habitual activity of human masseter.

    PubMed

    Michelotti, A; Farella, M; Gallo, L M; Veltri, A; Palla, S; Martina, R

    2005-07-01

    It has been suggested that occlusal interference may increase habitual activity in the jaw muscles and may lead to temporomandibular disorders (TMD). We tested these hypotheses by means of a double-blind randomized crossover experiment carried out on 11 young healthy females. Strips of gold foil were glued either on a selected occlusal contact area (active interference) or on the vestibular surface of the same tooth (dummy interference) and left for 8 days each. Electromyographic masseter activity was recorded in the natural environment by portable recorders under interference-free, dummy-interference, and active-interference conditions. The active occlusal interference caused a significant reduction in the number of activity periods per hour and in their mean amplitude. The EMG activity did not change significantly during the dummy-interference condition. None of the subjects developed signs and/or symptoms of TMD throughout the whole study, and most of them adapted fairly well to the occlusal disturbance.

  8. Pain and Cognitive Function Among Older Adults Living in the Community.

    PubMed

    van der Leeuw, Guusje; Eggermont, Laura H P; Shi, Ling; Milberg, William P; Gross, Alden L; Hausdorff, Jeffrey M; Bean, Jonathan F; Leveille, Suzanne G

    2016-03-01

    Pain related to many age-related chronic conditions is a burdensome problem in elderly adults and may also interfere with cognitive functioning. The purpose of this study was to examine the cross-sectional relationship between measures of pain severity and pain interference and cognitive performance in community-living older adults. We studied 765 participants in the Maintenance of Balance Independent Living Intellect and Zest (MOBILIZE) Boston Study, a population-based study of persons aged 70 and older. Global pain severity and interference were measured using the Brief Pain Inventory subscales. The neuropsychological battery included measures of attentional capacity (Trail Making Test A, WORLD Test), executive function (Trail Making Test B and Delta, Clock-in-a-Box, Letter Fluency), memory (Hopkins Verbal Learning Test), and a global composite measure of cognitive function. Multivariable linear regression models were used to analyze the relationship between pain and cognitive functioning. Elderly adults with more severe pain or more pain interference had poorer performance on memory tests and executive functioning compared to elders with none or less pain. Pain interference was also associated with impaired attentional capacity. Additional adjustment for chronic conditions, behaviors, and psychiatric medication resulted in attenuation of many of the observed associations. However, the association between pain interference and general cognitive function persisted. Our findings point to the need for further research to understand how chronic pain may contribute to decline in cognitive function and to determine strategies that may help in preventing or managing these potential consequences of pain on cognitive function in older adults. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Experiments in a three-dimensional adaptive-wall wind tunnel

    NASA Technical Reports Server (NTRS)

    Schairer, E. T.

    1983-01-01

    Three dimensional adaptive-wall experiments were performed in the Ames Research Center (ARC) 25- by 13-cm indraft wind tunnel. A semispan wing model was mounted to one sidewall of a test section with solid sidewalls, and slotted top and bottom walls. The test section had separate top and bottom plenums which were divided into streamwise and cross-stream compartments. An iterative procedure was demonstrated for measuring wall interference and for adjusting the plenum compartment pressures to eliminate such interference. The experiments were conducted at a freestream Mach number of 0.60 and model angles of attack between 0 and 6 deg. Although in all the experiments wall interference was reduced after the plenum pressures were adjusted, interference could not be completely eliminated.

  10. Comparison of airfoil results from an adaptive wall test section and a porous wall test section

    NASA Technical Reports Server (NTRS)

    Mineck, Raymond E.

    1989-01-01

    Two wind tunnel investigations were conducted to assess two different wall interference alleviation/correction techniques: adaptive test section walls and classical analytical corrections. The same airfoil model has been tested in the adaptive wall test section of the NASA-Langley 0.3 m Transonic Cryogenic Tunnel (TCT) and in the National Aeronautical Establishment (NAE) High Reynolds Number 2-D facility. The model has a 9 in. chord and a CAST 10-2/DOA 2 airfoil section. The 0.3 m TCT adaptive wall test section has four solid walls with flexible top and bottom walls. The NAE test section has porous top and bottom walls and solid side walls. The aerodynamic results corrected for top and bottom wall interference at Mach numbers from 0.3 to 0.8 at a Reynolds number of 10 by 1,000,000. Movement of the adaptive walls was used to alleviate the top and bottom wall interference in the test results from the NASA tunnel.

  11. Research for the jamming mechanism of high-frequency laser to the laser seeker

    NASA Astrophysics Data System (ADS)

    Zheng, Xingyuan; Zhang, Haiyang; Wang, Yunping; Feng, Shuang; Zhao, Changming

    2013-08-01

    High-frequency laser will be able to enter the enemy laser signal processing systems without encoded identification and a copy. That makes it one of the research directions of new interference sources. In order to study the interference mechanism of high-frequency laser to laser guided weapons. According to the principle of high-frequency laser interference, a series of related theoretical models such as a semi-active laser seeker coded identification model, a time door model, multi-signal processing model and a interference signal modulation processing model are established. Then seeker interfere with effective 3σ criterion is proposed. Based on this, the study of the effect of multi-source interference and signal characteristics of the effect of high repetition frequency laser interference are key research. According to the simulation system testing, the results show that the multi-source interference and interference signal frequency modulation can effectively enhance the interference effect. While the interference effect of the interference signal amplitude modulation is not obvious. The research results will provide the evaluation of high-frequency laser interference effect and provide theoretical references for high-frequency laser interference system application.

  12. Utility of an appropriate reporter assay: Heliotrine interferes with GAL4/upstream activation sequence-driven reporter gene systems.

    PubMed

    Luckert, Claudia; Hessel, Stefanie; Lampen, Alfonso; Braeuning, Albert

    2015-10-15

    Reporter gene assays are widely used for the assessment of transcription factor activation following xenobiotic exposure of cells. A critical issue with such assays is the possibility of interference of test compounds with the test system, for example, by direct inhibition of the reporter enzyme. Here we show that the pyrrolizidine alkaloid heliotrine interferes with reporter signals derived from GAL4-based nuclear receptor transactivation assays by a mechanism independent of luciferase enzyme inhibition. These data highlight the necessity to conduct proper control experiments in order to avoid perturbation of reporter assays by test chemicals. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Nonlinear transonic Wall-Interference Assessment/Correction (WIAC) procedures and application to cast-10 airfoil results from the NASA 0.3-m TCT 8- by 24-inch Slotted Wall Test Section (SWTS)

    NASA Technical Reports Server (NTRS)

    Gumbert, Clyde R.; Green, Lawrence L.; Newman, Perry A.

    1989-01-01

    From the time that wind tunnel wall interference was recognized to be significant, researchers have been developing methods to alleviate or account for it. Despite the best effort so far, it appears that no method is available which completely eliminates the effects due to the wind tunnel walls. This report discusses procedures developed for slotted wall and adaptive wall test sections of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) to assess and correct for the residual interference by methods consistent with the transonic nature of the tests.

  14. Capacity of dental equipment to interfere with cardiac implantable electrical devices.

    PubMed

    Lahor-Soler, Eduard; Miranda-Rius, Jaume; Brunet-Llobet, Lluís; Sabaté de la Cruz, Xavier

    2015-06-01

    Patients with cardiac implantable electrical devices should take precautions when exposed to electromagnetic fields. Possible interference as a result of proximity to electromagnets or electricity flow from electronic tools employed in clinical odontology remains controversial. The objective of this study was to examine in vitro the capacity of dental equipment to provoke electromagnetic interference in pacemakers and implantable cardioverter defibrillators. Six electronic dental instruments were tested on three implantable cardioverter defibrillators and three pacemakers from different manufacturers. A simulator model, submerged in physiological saline, with elements that reproduced life-size anatomic structures was used. The instruments were analyzed at differing distances and for different time periods of application. The dental instruments studied displayed significant differences in their capacity to trigger electromagnetic interference. Significant differences in the quantity of registered interference were observed with respect to the variables manufacturer, type of cardiac implant, and application distance but not with the variable time of application. The electronic dental equipment tested at a clinical application distance (20 cm) provoked only slight interference in the pacemakers and implantable cardioverter defibrillators employed, irrespective of manufacturer. © 2015 Eur J Oral Sci.

  15. Helicopter hub fairing and pylon interference drag

    NASA Technical Reports Server (NTRS)

    Graham, D. R.; Sung, D. Y.; Young, L. A.; Louie, A. W.; Stroub, R. H.

    1989-01-01

    A wind tunnel test was conducted to study the aerodynamics of helicopter hub and pylon fairings. The test was conducted in the 7-by 10 Foot Subsonic Wind Tunnel (Number 2) at Ames Research Center using a 1/5-scale XH-59A fuselage model. The primary focus of the test was on the rotor hub fairing and pylon mutual interference drag. Parametric studies of pylon and hub fairing geometry were also conducted. This report presents the major findings of the test as well as tabulated force and moment data, flow visualization photographs, and graphical presentations of the drag data. The test results indicate that substantial drag reduction can be attained through the use of a cambered hub fairing with circular arc upper surface and flat lower surface. Furthermore, a considerable portion of the overall drag reduction is attributed to the reduction in the hub-on-pylon interference drag. It is also observed that the lower surface curvature of the fairing has a strong influence on the hub fairing and on pylon interference drag. However, the drag reduction benefit that was obtained by using the cambered hub fairing with a flat lower surface was adversely affected by the clearance between the hub fairing and the pylon.

  16. The Auditory Verbal Learning Test (Rey AVLT): An Arabic Version

    ERIC Educational Resources Information Center

    Sharoni, Varda; Natur, Nazeh

    2014-01-01

    The goals of this study were to adapt the Rey Auditory Verbal Learning Test (AVLT) into Arabic, to compare recall functioning among age groups (6:0 to 17:11), and to compare gender differences on various memory dimensions (immediate and delayed recall, learning rate, recognition, proactive interferences, and retroactive interferences). This…

  17. IDENTIFICATION OF ALGAE WHICH INTERFERE WITH THE DETECTION OF GIARDIA CYSTS AND CRYPTOSPORIDIUM OOCYSTS AND A METHOD FOR ALLEVIATING THIS INTERFERENCE

    EPA Science Inventory

    Fifty-four algal species were tested for cross-reaction in the American Society for Testing and Materials Giardia/Cryptosporidium indirect immunofluorescence assay, and 24 showed some degree of fluorescence. Two species, Navicula minima and Synechococcus elongatus, exhibited a br...

  18. "Testing during Study Insulates against the Buildup of Proactive Interference": Correction

    ERIC Educational Resources Information Center

    Szpunar, Karl K.; McDermott, Kathleen B.; Roedigger, Henry L., III

    2009-01-01

    Reports an error in "Testing during study insulates against the buildup of proactive interference" by Karl K. Szpunar, Kathleen B. McDermott and Henry L. Roediger III ("Journal of Experimental Psychology: Learning, Memory, and Cognition," 2008[Nov], Vol 34[6], 1392-1399). Incorrect figures were printed due to an error in the…

  19. 77 FR 20756 - Implementation of the Local Community Radio Act of 2010; Revision of Service and Eligibility...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-06

    ... the technical report entitled `Experimental Measurements of the Third-Adjacent Channel Impacts of Low... rules designed to prevent any predicted interference. 31. We propose to adopt a basic threshold test. This test is designed to closely track the interference standard developed by Mitre, without...

  20. Test Plan for Experimental Measurements of Radio Noise and Electromagnetic Interference at Logan and Burlington Airports

    DOT National Transportation Integrated Search

    1979-10-01

    A test plan is designed to" (a) evaluate the performance of several types of LORAN-C receivers in the vicinity of both a large metropolitan and a small rural airport, (b) measure the electromagnetic interference in the LORAN-C band (100+/-50 KHZ) at ...

  1. The Color-Word Interference Test and Its Relation to Performance Impairment under Auditory Distraction.

    ERIC Educational Resources Information Center

    Thackray, Richard I.; And Others

    The ability to resist distraction is an important requirement for air traffic controllers. The study examined the relationship between performance on the Stroop color-word interference test (a suggested measure of distraction susceptibility) and impairment under auditory distraction on a task requiring the subject to generate random sequences of…

  2. Investigation of Conceptual Change about Double-Slit Interference in Secondary School Physics

    ERIC Educational Resources Information Center

    Kocakulah, Mustafa Sabri; Kural, Mehmet

    2010-01-01

    In this study, whether or not constructivist teaching of double-slit interference of light has a positive effect on the secondary school students' conceptual change is examined. An achievement test, a conceptual understanding test and semi-structured interviews were used as data collection tools in this mixed methods research. Experimental group…

  3. Comparing cognition by integrating concept learning, proactive interference, and list memory.

    PubMed

    Wright, Anthony A; Kelly, Debbie M; Katz, Jeffrey S

    2018-06-01

    This article describes an approach for training a variety of species to learn the abstract concept of same/different, which in turn forms the basis for testing proactive interference and list memory. The stimulus set for concept-learning training was progressively doubled from 8, 16, 32, 64, 128 . . . to 1,024 different pictures with novel-stimulus transfer following learning. All species fully learned the same/different abstract concept: capuchin and rhesus monkeys learned more readily than pigeons; nutcrackers and magpies were at least equivalent to monkeys and transferred somewhat better following initial training sets. A similar task using the 1,024-picture set plus delays was used to test proactive interference on occasional trials. Pigeons revealed greater interference with 10-s than with 1-s delays, whereas delay time had no effect on rhesus monkeys, suggesting that the monkeys' interference was event based. This same single-item same/different task was expanded to a 4-item list memory task to test animal list memory. Humans were tested similarly with lists of kaleidoscope pictures. Delays between the list and test were manipulated, resulting in strong initial recency effects (i.e., strong 4th-item memory) at short delays and changing to a strong primacy effect (i.e., strong 1st-item memory) at long delays (pigeons 0-s to 10-s delays; monkeys 0-s to 30-s delays; humans 0-s to 100-s delays). Results and findings are discussed in terms of these species' cognition and memory comparisons, evolutionary implications, and future directions for testing other species in these synergistically related tasks.

  4. Assessment of virus interference in a test-negative study of influenza vaccine effectiveness

    PubMed Central

    Feng, Shuo; Fowlkes, Ashley L.; Steffens, Andrea; Finelli, Lyn; Cowling, Benjamin J.

    2017-01-01

    Background The observational test-negative study design is used to estimate vaccine effectiveness against influenza virus infection. An important assumption of the test-negative design is that vaccination does not affect the risk of infection with another virus. If such virus interference occurred, detection of other respiratory viruses would be more common among influenza vaccine recipients and vaccine effectiveness estimates could differ. We evaluated the potential for virus interference using data from the Influenza Incidence Surveillance Project. Methods From 2010 to 2013, outpatients presenting to clinics in 13 US jurisdictions with acute respiratory infections were tested for influenza and other respiratory viruses. We investigated whether virus interference might affect vaccine effectiveness estimates by first evaluating the sensitivity of estimates using alternative control groups that include or exclude patients with other respiratory virus detections by age group and early/middle/late stage of influenza seasons. Second, we evaluated the association between influenza vaccination receipt and other respiratory virus detection among influenza test negative patients. Results Influenza was detected in 3,743/10,650 patients (35%), and overall vaccine effectiveness was 47% (95% CI: 42%, 52%). Estimates using each control group were consistent overall or when stratified by age groups, and there were no differences among early, middle, or late phase during influenza season. We found no associations between detection of other respiratory viruses and receipt of influenza vaccination. Conclusions In this 3-year test-negative design study in an outpatient setting in the United States, we found no evidence of virus interference or impact on influenza vaccine effectiveness estimation. PMID:28362642

  5. IFT&E Industry Report Wind Turbine-Radar Interference Test Summary.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karlson, Benjamin; LeBlanc, Bruce Philip.; Minster, David G

    2014-10-01

    Wind turbines have grown in size and capacity with today's average turbine having a power capacity of around 1.9 MW, reaching to heights of over 495 feet from ground to blade tip, and operating with speeds at the tip of the blade up to 200 knots. When these machines are installed within the line-of-sight of a radar system, they can cause significant clutter and interference, detrimentally impacting the primary surveillance radar (PSR) performance. The Massachusetts Institute of Technology's Lincoln Laboratory (MIT LL) and Sandia National Laboratories (SNL) were co-funded to conduct field tests and evaluations over two years in ordermore » to: I. Characterize the impact of wind turbines on existing Program-of-Record (POR) air surveillance radars; II. Assess near-term technologies proposed by industry that have the potential to mitigate the interference from wind turbines on radar systems; and III. Collect data and increase technical understanding of interference issues to advance development of long-term mitigation strategies. MIT LL and SNL managed the tests and evaluated resulting data from three flight campaigns to test eight mitigation technologies on terminal (short) and long-range (60 nmi and 250 nmi) radar systems. Combined across the three flight campaigns, more than 460 of hours of flight time were logged. This paper summarizes the Interagency Field Test & Evaluation (IFT&E) program and publicly- available results from the tests. It will also discuss the current wind turbine-radar interference evaluation process within the government and a proposed process to deploy mitigation technologies.« less

  6. Revealing past memories: proactive interference and ketamine-induced memory deficits.

    PubMed

    Chrobak, James J; Hinman, James R; Sabolek, Helen R

    2008-04-23

    Memories of events that occur often are sensitive to interference from memories of similar events. Proactive interference plays an important and often unexamined role in memory testing for spatially and temporally unique events ("episodes"). Ketamine (NMDA receptor antagonist) treatment in humans and other mammals induces a constellation of cognitive deficits, including impairments in working and episodic memory. We examined the effects of the ketamine (2.5-100 mg/kg) on the acquisition, retrieval, and retention of memory in a delayed-match-to-place radial water maze task that can be used to assess proactive interference. Ketamine (2.5-25 mg/kg, i.p.) given 20 min before the sample trial, impaired encoding. The first errors made during the test trial were predominantly to arms located spatially adjacent to the goal arm, suggesting an established albeit weakened representation. Ketamine (25-100 mg/kg) given immediately after the sample trial had no effect on retention. Ketamine given before the test trial impaired retrieval. First errors under the influence of ketamine were predominantly to the goal location of the previous session. Thus, ketamine treatment promoted proactive interference. These memory deficits were not state dependent, because ketamine treatment at both encoding and retrieval only increased the number of errors during the test session. These data demonstrate the competing influence of distinct memory representations during the performance of a memory task in the rat. Furthermore, they demonstrate the subtle disruptive effects of the NMDA antagonist ketamine on both encoding and retrieval. Specifically, ketamine treatment disrupted retrieval by promoting proactive interference from previous episodic representations.

  7. Eighteen-month-olds' memory interference and distraction in a modified A-not-B task is not associated with their anticipatory looking in a false-belief task.

    PubMed

    Zmyj, Norbert; Prinz, Wolfgang; Daum, Moritz M

    2015-01-01

    Infants' performance in non-verbal false-belief tasks is often interpreted as if they have understood false beliefs. This view has been questioned by a recent account that explains infants' performance in non-verbal false-belief tasks as the result of susceptibility to memory interference and distraction. We tested this alternative account by investigating the relationship between infants' false-belief understanding, susceptibility to memory interference and distraction, and general cognitive development in 18-month-old infants (N = 22). False-belief understanding was tested in an anticipatory looking paradigm of a standard false-belief task. Susceptibility to memory interference and distraction was tested in a modified A-not-B task. Cognitive development was measured via the Mental Scale of the Bayley Scales of Infant Development. We did not find any relationship between infants' performance in the false-belief task and the A-not-B task, even after controlling for cognitive development. This study shows that there is no ubiquitous relation between susceptibility to memory interference and distraction and performance in a false-belief task in infancy.

  8. Eighteen-month-olds’ memory interference and distraction in a modified A-not-B task is not associated with their anticipatory looking in a false-belief task

    PubMed Central

    Zmyj, Norbert; Prinz, Wolfgang; Daum, Moritz M.

    2015-01-01

    Infants’ performance in non-verbal false-belief tasks is often interpreted as if they have understood false beliefs. This view has been questioned by a recent account that explains infants’ performance in non-verbal false-belief tasks as the result of susceptibility to memory interference and distraction. We tested this alternative account by investigating the relationship between infants’ false-belief understanding, susceptibility to memory interference and distraction, and general cognitive development in 18-month-old infants (N = 22). False-belief understanding was tested in an anticipatory looking paradigm of a standard false-belief task. Susceptibility to memory interference and distraction was tested in a modified A-not-B task. Cognitive development was measured via the Mental Scale of the Bayley Scales of Infant Development. We did not find any relationship between infants’ performance in the false-belief task and the A-not-B task, even after controlling for cognitive development. This study shows that there is no ubiquitous relation between susceptibility to memory interference and distraction and performance in a false-belief task in infancy. PMID:26157409

  9. Experimental evaluation of blockage ratio and plenum evacuation system flow effects on pressure distribution for bodies of revolution in 0.1 scale model test section of NASA Lewis Research Center's proposed altitude wind tunnel

    NASA Technical Reports Server (NTRS)

    Burley, Richard R.; Harrington, Douglas E.

    1987-01-01

    An experimental investigation was conducted in the slotted test section of the 0.1-scale model of the proposed Altitude Wind Tunnel to evaluate wall interference effects at tunnel Mach numbers from 0.70 to 0.95 on bodies of revolution with blockage rates of 0.43, 3, 6, and 12 percent. The amount of flow that had to be removed from the plenum chamber (which surrounded the slotted test section) by the plenum evacuation system (PES) to eliminate wall interference effects was determined. The effectiveness of tunnel reentry flaps in removing flow from the plenum chamber was examined. The 0.43-percent blockage model was the only one free of wall interference effects with no PES flow. Surface pressures on the forward part of the other models were greater than interference-free results and were not influenced by PES flow. Interference-free results were achieved on the aft part of the 3- and 6-percent blockage models with the proper amount of PES flow. The required PES flow was substantially reduced by opening the reentry flaps.

  10. Potential GPRS 900/180-MHz and WCDMA 1900-MHz interference to medical devices.

    PubMed

    Iskra, Steve; Thomas, Barry W; McKenzie, Ray; Rowley, Jack

    2007-10-01

    This study compared the potential for interference to medical devices from radio frequency (RF) fields radiated by GSM 900/1800-MHz, general packet radio service (GPRS) 900/1800-MHz, and wideband code division multiple access (WCDMA) 1900-MHz handsets. The study used a balanced half-wave dipole antenna, which was energized with a signal at the standard power level for each technology, and then brought towards the medical device while noting the distance at which interference became apparent. Additional testing was performed with signals that comply with the requirements of the international immunity standard to RF fields, IEC 61000-4-3. The testing provides a sense of the overall interference impact that GPRS and WCDMA (frequency division duplex) may have, relative to current mobile technologies, and to the internationally recognized standard for radiated RF immunity. Ten medical devices were tested: two pulse oximeters, a blood pressure monitor, a patient monitor, a humidifier, three models of cardiac defibrillator, and two models of infusion pump. Our conclusion from this and a related study on consumer devices is that WCDMA handsets are unlikely to be a significant interference threat to medical electronics at typical separation distances.

  11. Malfunction of medical equipment as a result of mains borne interference.

    PubMed

    Railton, R; Currie, G D; Corner, G A; Evans, A L

    1993-08-01

    Medical equipment has become more intelligent as the manufacturers have incorporated the latest microprocessor based technology. Equipment malfunction can be caused at any time by inherent errors in the control program but it is particularly important that this is designed to cope with the effects of electrical interference which, in addition, may cause corruption of the software. We have considered interference found in the mains supply in the hospital environment. Using a test protocol with appropriate interference simulators, a wide range of medical equipment was removed temporarily from use and its immunity to electrical mains borne interference tested. Battery operated mains rechargeable devices were unaffected by mains voltage variations including drop-outs and sags whereas mains powered devices were affected to varying degrees of severity. In particular, repetitive drop-outs caused loss of power due to fuse blowing in some life support equipment. Impulses affected 25% and pulse bursts 50% of the equipment tested with some evidence that the more recent designs coped better. The EEC Directive on electro-medical compatibility compliance may cause the design of equipment to be improved but hospitals will have to cope with the above problems in their existing equipment for many years to come.

  12. Paradoxical effects of testing: retrieval enhances both accurate recall and suggestibility in eyewitnesses.

    PubMed

    Chan, Jason C K; Langley, Moses M

    2011-01-01

    Although retrieval practice typically enhances memory retention, it can also impair subsequent eyewitness memory accuracy (Chan, Thomas, & Bulevich, 2009). Specifically, participants who had taken an initial test about a witnessed event were more likely than nontested participants to recall subsequently encountered misinformation—an effect we called retrieval-enhanced suggestibility (RES). Here, we sought to test the generality of RES and to further elucidate its underlying mechanisms. To that end, we tested a dual mechanism account, which suggests that RES occurs because initial testing (a) enhances learning of the later misinformation by reducing proactive interference and (b) causes the reactivated memory trace to be more susceptible to later interference (i.e., a reconsolidation account). Three major findings emerged. First, RES was found after a 1-week delay, where a robust testing benefit occurred for event details that were not contradicted by later misinformation. Second, blockage of reconsolidation was unnecessary for RES to occur. Third, initial testing enhanced learning of the misinformation even when proactive interference played a minimal role.

  13. The effect of interference on temporal order memory for random and fixed sequences in nondemented older adults.

    PubMed

    Tolentino, Jerlyn C; Pirogovsky, Eva; Luu, Trinh; Toner, Chelsea K; Gilbert, Paul E

    2012-05-21

    Two experiments tested the effect of temporal interference on order memory for fixed and random sequences in young adults and nondemented older adults. The results demonstrate that temporal order memory for fixed and random sequences is impaired in nondemented older adults, particularly when temporal interference is high. However, temporal order memory for fixed sequences is comparable between older adults and young adults when temporal interference is minimized. The results suggest that temporal order memory is less efficient and more susceptible to interference in older adults, possibly due to impaired temporal pattern separation.

  14. An experimental study of wall adaptation and interference assessment using Cauchy integral formula

    NASA Technical Reports Server (NTRS)

    Murthy, A. V.

    1991-01-01

    This paper summarizes the results of an experimental study of combined wall adaptation and residual interference assessment using the Cauchy integral formula. The experiments were conducted on a supercritical airfoil model in the Langley 0.3-m Transonic Cryogenic Tunnel solid flexible wall test section. The ratio of model chord to test section height was about 0.7. The method worked satisfactorily in reducing the blockage interference and demonstrated the primary requirement for correcting for the blockage effects at high model incidences to correctly determine high lift characteristics. The studies show that the method has potential for reducing the residual interference to considerably low levels. However, corrections to blockage and upwash velocities gradients may still be required for the final adapted wall shapes.

  15. The Effect of Interference on Temporal Order Memory for Random and Fixed Sequences in Nondemented Older Adults

    ERIC Educational Resources Information Center

    Tolentino, Jerlyn C.; Pirogovsky, Eva; Luu, Trinh; Toner, Chelsea K.; Gilbert, Paul E.

    2012-01-01

    Two experiments tested the effect of temporal interference on order memory for fixed and random sequences in young adults and nondemented older adults. The results demonstrate that temporal order memory for fixed and random sequences is impaired in nondemented older adults, particularly when temporal interference is high. However, temporal order…

  16. The similar effects of verbal and non-verbal intervening tasks on word recall in an elderly population.

    PubMed

    Williams, B R; Sullivan, S K; Morra, L F; Williams, J R; Donovick, P J

    2014-01-01

    Vulnerability to retroactive interference has been shown to increase with cognitive aging. Consistent with the findings of memory and aging literature, the authors of the California Verbal Learning Test-II (CVLT-II) suggest that a non-verbal task be administered during the test's delay interval to minimize the effects of retroactive interference on delayed recall. The goal of the present study was to determine the extent to which retroactive interference caused by non-verbal and verbal intervening tasks affects recall of verbal information in non-demented, older adults. The effects of retroactive interference on recall of words during Long-Delay recall on the California Verbal Learning Test-II (CVLT-II) were evaluated. Participants included 85 adults age 60 and older. During a 20-minute delay interval on the CVLT-II, participants received either a verbal (WAIS-III Vocabulary or Peabody Picture Vocabulary Test-IIIB) or non-verbal (Raven's Standard Progressive Matrices or WAIS-III Block Design) intervening task. Similarly to previous research with young adults (Williams & Donovick, 2008), older adults recalled the same number of words across all groups, regardless of the type of intervening task. These findings suggest that the administration of verbal intervening tasks during the CVLT-II do not elicit more retroactive interference than non-verbal intervening tasks, and thus verbal tasks need not be avoided during the delay interval of the CVLT-II.

  17. Mobile phone interference with medical equipment and its clinical relevance: a systematic review.

    PubMed

    Lawrentschuk, Nathan; Bolton, Damien M

    2004-08-02

    To conduct a systematic review of studies on clinically relevant digital mobile phone electromagnetic interference with medical equipment. MEDLINE and SUMSEARCH were searched for the period 1966-2004. The Cochrane Library and Database of Abstracts of Reviews of Effects were also searched for systematic reviews. Studies were eligible if published in a peer-reviewed journal in English, and if they included testing of digital mobile phones for clinically relevant interference with medical equipment used to monitor or treat patients, but not implantable medical devices. As there was considerable heterogeneity in medical equipment studied and the conduct of testing, results were summarised rather than subjected to meta-analysis. Clinically relevant electromagnetic interference (EMI) secondary to mobile phones potentially endangering patients occurred in 45 of 479 devices tested at 900 MHz and 14 of 457 devices tested at 1800 MHz. However, in the largest studies, the prevalence of clinically relevant EMI was low. Most clinically relevant EMI occurred when mobile phones were used within 1 m of medical equipment. Although testing was not standardised between studies and equipment tested was not identical, it is of concern that at least 4% of devices tested in any study were susceptible to clinically relevant EMI. All studies recommend some type of restriction of mobile phone use in hospitals, with use greater than 1 m from equipment and restrictions in clinical areas being the most common.

  18. An Initial Look at Adjacent Band Interference Between Aeronautical Mobile Telemetry and Long-Term Evolution Wireless Service

    DTIC Science & Technology

    2016-07-04

    required analysis, and further testing. 15. SUBJECT TERMS Adjacent Channel Interference, ACI, LTE -A, LTE , PCM/FM, SOQPSK-TG, ARTM CPM, AWS-3, User...Interference, ACI, LTE -A, LTE , PCM/FM, SOQPSK-TG, ARTM CPM, AWS-3, User Equipment, UE, Evolved Node B, eNodeB, Resource Blocks INTRODUCTION “On...these questions make necessary an improved understanding of the interferers that can be obtained only by hands-on measurements . This work will

  19. Residual interference assessment in adaptive wall wind tunnels

    NASA Technical Reports Server (NTRS)

    Murthy, A. V.

    1989-01-01

    A two-variable method is presented which is suitable for on-line calculation of residual interference in airfoil testing in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-M TCT). The method applies the Cauchy's integral formula to the closed contour formed by the contoured top and bottom walls, and the upstream and downstream ends. The measured top and bottom wall pressures and position are used to calculate the correction to the test Mach number and the airfoil angle of attack. Application to specific data obtained in the 0.3-M TCT adaptive wall test section demonstrates the need to assess residual interference to ensure that the desired level of wall streamlining is achieved. A FORTRAN computer program was developed for on-line calculation of the residual corrections during airfoil tests in the 0.3-M TCT.

  20. Wind tunnel investigation of Nacelle-Airframe interference at Mach numbers of 0.9 to 1.4-pressure data, volume 2

    NASA Technical Reports Server (NTRS)

    Bencze, D. P.

    1976-01-01

    Detailed interference force and pressure data were obtained on a representative wing-body nacelle combination at Mach numbers of 0.9 to 1.4. The model consisted of a delta wing-body aerodynamic force model with four independently supported nacelles located beneath the wing-body combination. The primary variables examined included Mach number, angle of attack, nacelle position, and nacelle mass flow ratio. Four different configurations were tested to identify various interference forces and pressures on each component; these included tests of the isolated nacelle, the isolated wing-body combination, the four nacelles as a unit, and the total wing-body-nacelle combination. Nacelle axial location, relative to both the wing-body combination and to each other, was the most important variable in determining the net interference among the components. The overall interference effects were found to be essentially constant over the operating angle-of-attack range of the configuration, and nearly independent of nacelle mass flow ratio.

  1. Intrusive trauma recollections is associated with impairment of interference inhibition and psychomotor speed in PTSD.

    PubMed

    Kertzman, Semion; Avital, Avi; Weizman, Abraham; Segal, Michael

    2014-10-01

    Intrusive cognitions that enter consciousness involuntarily are prominent symptoms of posttraumatic stress disorder (PTSD). The present study aimed to identify neuropsychological mechanisms involved. Fifty PTSD outpatients and 50 healthy controls were tested using Finger Tapping, Simple and Choice Reaction Times and Stroop Tasks, to measure motor, psychomotor speed, response selection, and interference inhibition ability respectively. PTSD patients performed poorly in all tests, presumably owing to their generalized slowness of information processing and motor reaction. Psychomotor speed was a predictor of slowness and high error rate during the Stroop. Impaired inhibition, as measured by the interference index of the Stroop task, explained 9.7% of the predicated variance in frequency of re-experiencing PTSD symptoms and 23.5% of the predicated variance in augmentation of the interference response time. Impaired interference control may be related to internal (re-experiencing) and external (sensory) stimuli that leads to cognitive deficits in PTSD patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Measuring pain phenomena after spinal cord injury: Development and psychometric properties of the SCI-QOL Pain Interference and Pain Behavior assessment tools.

    PubMed

    Cohen, Matthew L; Kisala, Pamela A; Dyson-Hudson, Trevor A; Tulsky, David S

    2018-05-01

    To develop modern patient-reported outcome measures that assess pain interference and pain behavior after spinal cord injury (SCI). Grounded-theory based qualitative item development; large-scale item calibration field-testing; confirmatory factor analyses; graded response model item response theory analyses; statistical linking techniques to transform scores to the Patient Reported Outcome Measurement Information System (PROMIS) metric. Five SCI Model Systems centers and one Department of Veterans Affairs medical center in the United States. Adults with traumatic SCI. N/A. Spinal Cord Injury - Quality of Life (SCI-QOL) Pain Interference item bank, SCI-QOL Pain Interference short form, and SCI-QOL Pain Behavior scale. Seven hundred fifty-seven individuals with traumatic SCI completed 58 items addressing various aspects of pain. Items were then separated by whether they assessed pain interference or pain behavior, and poorly functioning items were removed. Confirmatory factor analyses confirmed that each set of items was unidimensional, and item response theory analyses were used to estimate slopes and thresholds for the items. Ultimately, 7 items (4 from PROMIS) comprised the Pain Behavior scale and 25 items (18 from PROMIS) comprised the Pain Interference item bank. Ten of these 25 items were selected to form the Pain Interference short form. The SCI-QOL Pain Interference item bank and the SCI-QOL Pain Behavior scale demonstrated robust psychometric properties. The Pain Interference item bank is available as a computer adaptive test or short form for research and clinical applications, and scores are transformed to the PROMIS metric.

  3. Experimental investigation of wall shock cancellation and reduction of wall interference in transonic testing

    NASA Technical Reports Server (NTRS)

    Ferri, A.; Roffe, G.

    1975-01-01

    A series of experiments were performed to evaluate the effectiveness of a three-dimensional land and groove wall geometry and a variable permeability distribution to reduce the interference produced by the porous walls of a supercritical transonic test section. The three-dimensional wall geometry was found to diffuse the pressure perturbations caused by small local mismatches in wall porosity permitting the use of a relatively coarse wall porosity control to reduce or eliminate wall interference effects. The wall porosity distribution required was found to be a sensitive function of Mach number requiring that the Mach number repeatability characteristics of the test apparatus be quite good. The effectiveness of a variable porosity wall is greatest in the upstream region of the test section where the pressure differences across the wall are largest. An effective variable porosity wall in the down stream region of the test section requires the use of a slightly convergent test section geometry.

  4. Consecutive learning of opposing unimanual motor tasks using the right arm followed by the left arm causes intermanual interference

    PubMed Central

    Thürer, Benjamin; Stein, Thorsten

    2017-01-01

    Intermanual transfer (motor memory generalization across arms) and motor memory interference (impairment of retest performance in consecutive motor learning) are well-investigated motor learning phenomena. However, the interplay of these phenomena remains elusive, i.e., whether intermanual interference occurs when two unimanual tasks are consecutively learned using different arms. Here, we examine intermanual interference when subjects consecutively adapt their right and left arm movements to novel dynamics. We considered two force field tasks A and B which were of the same structure but mirrored orientation (B = -A). The first test group (ABA-group) consecutively learned task A using their right arm and task B using their left arm before being retested for task A with their right arm. Another test group (AAA-group) learned only task A in the same right-left-right arm schedule. Control subjects learned task A using their right arm without intermediate left arm learning. All groups were able to adapt their right arm movements to force field A and both test groups showed significant intermanual transfer of this initial learning to the contralateral left arm of 21.9% (ABA-group) and 27.6% (AAA-group). Consecutively, both test groups adapted their left arm movements to force field B (ABA-group) or force field A (AAA-group). For the ABA-group, left arm learning caused significant intermanual interference of the initially learned right arm task (68.3% performance decrease). The performance decrease of the AAA-group (10.2%) did not differ from controls (15.5%). These findings suggest that motor control and learning of right and left arm movements involve partly similar neural networks or underlie a vital interhemispheric connectivity. Moreover, our results suggest a preferred internal task representation in extrinsic Cartesian-based coordinates rather than in intrinsic joint-based coordinates because interference was absent when learning was performed in extrinsically equivalent fashion (AAA-group) but interference occurred when learning was performed in intrinsically equivalent fashion (ABA-group). PMID:28459833

  5. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.

    PubMed

    Nah, Hyunjin; Lee, Sang-Guk; Lee, Kyeong-Seob; Won, Jae-Hee; Kim, Hyun Ok; Kim, Jeong-Ho

    2016-02-01

    The aim of this study was to estimate bilirubin interference and accuracy of six routine methods for measuring creatinine compared with isotope dilution-liquid chromatography mass spectrometry (ID-LC/MS). A total of 40 clinical serum samples from 31 patients with serum total bilirubin concentration >68.4μmol/L were collected. Serum creatinine was measured using two enzymatic reagents and four Jaffe reagents as well as ID-LC/MS. Correlations between bilirubin concentration and percent difference in creatinine compared with ID-LC/MS were analyzed to investigate bilirubin interference. Bias estimations between the six reagents and ID-LC/MS were performed. Recovery tests using National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 967a were also performed. Both the enzymatic methods showed no bilirubin interference. However, three of the four Jaffe methods demonstrated significant bilirubin concentration-dependent interference in samples with creatinine levels <53μmol/L, and two of them showed significant bilirubin interference in samples with creatinine levels ranging from 53.0 to 97.2μmol/L. Comparison of these methods with ID-LC/MS using patients' samples with elevated bilirubin revealed that the tested methods failed to achieve the bias goal at especially low levels of creatinine. In addition, recovery test using NIST SRM 967a showed that bias in one Jaffe method and two enzymatic methods did not achieve the bias goal at either low or high level of creatinine, indicating they had calibration bias. One enzymatic method failed to achieve all the bias goals in both comparison experiment and recovery test. It is important to understand that both bilirubin interference and calibration traceability to ID-LC/MS should be considered to improve the accuracy of creatinine measurement. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Consecutive learning of opposing unimanual motor tasks using the right arm followed by the left arm causes intermanual interference.

    PubMed

    Stockinger, Christian; Thürer, Benjamin; Stein, Thorsten

    2017-01-01

    Intermanual transfer (motor memory generalization across arms) and motor memory interference (impairment of retest performance in consecutive motor learning) are well-investigated motor learning phenomena. However, the interplay of these phenomena remains elusive, i.e., whether intermanual interference occurs when two unimanual tasks are consecutively learned using different arms. Here, we examine intermanual interference when subjects consecutively adapt their right and left arm movements to novel dynamics. We considered two force field tasks A and B which were of the same structure but mirrored orientation (B = -A). The first test group (ABA-group) consecutively learned task A using their right arm and task B using their left arm before being retested for task A with their right arm. Another test group (AAA-group) learned only task A in the same right-left-right arm schedule. Control subjects learned task A using their right arm without intermediate left arm learning. All groups were able to adapt their right arm movements to force field A and both test groups showed significant intermanual transfer of this initial learning to the contralateral left arm of 21.9% (ABA-group) and 27.6% (AAA-group). Consecutively, both test groups adapted their left arm movements to force field B (ABA-group) or force field A (AAA-group). For the ABA-group, left arm learning caused significant intermanual interference of the initially learned right arm task (68.3% performance decrease). The performance decrease of the AAA-group (10.2%) did not differ from controls (15.5%). These findings suggest that motor control and learning of right and left arm movements involve partly similar neural networks or underlie a vital interhemispheric connectivity. Moreover, our results suggest a preferred internal task representation in extrinsic Cartesian-based coordinates rather than in intrinsic joint-based coordinates because interference was absent when learning was performed in extrinsically equivalent fashion (AAA-group) but interference occurred when learning was performed in intrinsically equivalent fashion (ABA-group).

  7. Potential for Personal Digital Assistant interference with implantable cardiac devices.

    PubMed

    Tri, Jeffrey L; Trusty, Jane M; Hayes, David L

    2004-12-01

    To determine whether the wireless local area network (WLAN) technology, specifically the Personal Digital Assistant (PDA), interferes with implantable cardiac pacemakers and defibrillators. Various pacemakers and defibrillators were tested in vitro at the Mayo Clinic in Rochester, Minn, between March 6 and July 30, 2003. These cardiac devices were exposed to an HP Compaq IPAQ PDA fitted with a Cisco Aironet WLAN card. Initial testing was designed to show whether the Aironet card radiated energy in a consistent pattern from the antenna of the PDA to ensure that subsequent cardiac device testing would not be affected by the orientation of the PDA to the cardiac device. Testing involved placing individual cardiac devices in a simulator and uniformly exposing each device at its most sensitive programmable value to the WLAN card set to maximum power. During testing with the Cisco WLAN Aironet card, all devices programmed to the unipolar or bipolar configuration single- or dual-chamber mode had normal pacing and sensing functions and exhibited no effects of electromagnetic interference except for 1 implantable cardioverter-defibrillator (ICD). This aberration was determined to relate to the design of the investigators' testing apparatus and not to the output of the PDA. The ICD device appropriately identified and labeled the electromagnetic aberration as "noise." We documented no electromagnetic interference caused by the WLAN technology by using in vitro testing of pacemakers and ICDs; however, testing ideally should be completed in vivo to confirm the lack of any clinically important interactions.

  8. Contributions of Response Set and Semantic Relatedness to Cross-Modal Stroop-Like Picture--Word Interference in Children and Adults

    ERIC Educational Resources Information Center

    Hanauer, John B.; Brooks, Patricia J.

    2005-01-01

    Resistance to interference from irrelevant auditory stimuli undergoes development throughout childhood. To test whether semantic processes account for age-related changes in a Stroop-like picture-word interference effect, children (3-to 12-year-olds) and adults named pictures while listening to words varying in terms of semantic relatedness to the…

  9. Language Proficiency and Executive Control in Proactive Interference: Evidence from Monolingual and Bilingual Children and Adults

    ERIC Educational Resources Information Center

    Bialystok, Ellen; Feng, Xiaojia

    2009-01-01

    Two studies are reported in which monolingual and bilingual children (Study 1) and adults (Study 2) completed a memory task involving proactive interference. In both cases, the bilinguals attained lower scores on a vocabulary test than monolinguals but performed the same on the proactive interference task. For the children, bilinguals made fewer…

  10. The Effects of Pictorial Aids on Inferentially-produced Interference in Younger and Older Children's Sentence Learning.

    ERIC Educational Resources Information Center

    Truman, Diane L.

    As part of a series of studies dealing with varieties of interference in sentence learning as assessed by multiple choice tests, a study was undertaken to explore the effects of pictures on inferentially produced interference in recognition memory for sentence information. The subjects were 104 first grade students and 104 fourth, fifth, and sixth…

  11. A Test of Bayesian Observer Models of Processing in the Eriksen Flanker Task

    ERIC Educational Resources Information Center

    White, Corey N.; Brown, Scott; Ratcliff, Roger

    2012-01-01

    Two Bayesian observer models were recently proposed to account for data from the Eriksen flanker task, in which flanking items interfere with processing of a central target. One model assumes that interference stems from a perceptual bias to process nearby items as if they are compatible, and the other assumes that the interference is due to…

  12. Comparison study and thoron interference test of different radon monitors.

    PubMed

    Sumesh, C G; Kumar, A Vinod; Tripathi, R M; Puranik, V D

    2013-03-01

    A comparison study and thoron interference test for different continuous radon monitors were carried out. The comparison study includes three passive diffusion monitors [one pulse ionisation chamber based-Alpha Guard and two silicon semi-conductor based-Radon Scout Plus (RSP)] and one silicon semi-conductor-based active radon thoron discriminating monitor--RAD 7. Radon emanation standard, supplied by National Institute of Science and Technology, has been utilised for the comparison study to qualify the calibration of the continuous radon monitors. All the instruments showed good agreement with the estimated radon concentration using (226)Ra/(222)Rn emanation standard. It was found that the active radon monitoring system is having a higher initial response towards the transient radon concentration than the passive radon monitors studied. The instruments measuring radon concentration without energy discrimination are likely to have some sensitivity towards the thoron concentration. Thus, thoron interference study was carried out in the above monitors. Nine percent interference in measured radon concentration in the Alpha Guard monitor and 4 % interference in the semi-conductor-based RSP monitors was observed. Study indicates that the interference of thoron in radon monitors depends on the area of diffusion of gas, volume of detection and sensitivity factor.

  13. Interference correction by extracting the information of interference dominant regions: Application to near-infrared spectra

    NASA Astrophysics Data System (ADS)

    Bi, Yiming; Tang, Liang; Shan, Peng; Xie, Qiong; Hu, Yong; Peng, Silong; Tan, Jie; Li, Changwen

    2014-08-01

    Interference such as baseline drift and light scattering can degrade the model predictability in multivariate analysis of near-infrared (NIR) spectra. Usually interference can be represented by an additive and a multiplicative factor. In order to eliminate these interferences, correction parameters are needed to be estimated from spectra. However, the spectra are often mixed of physical light scattering effects and chemical light absorbance effects, making it difficult for parameter estimation. Herein, a novel algorithm was proposed to find a spectral region automatically that the interesting chemical absorbance and noise are low, that is, finding an interference dominant region (IDR). Based on the definition of IDR, a two-step method was proposed to find the optimal IDR and the corresponding correction parameters estimated from IDR. Finally, the correction was performed to the full spectral range using previously obtained parameters for the calibration set and test set, respectively. The method can be applied to multi target systems with one IDR suitable for all targeted analytes. Tested on two benchmark data sets of near-infrared spectra, the performance of the proposed method provided considerable improvement compared with full spectral estimation methods and comparable with other state-of-art methods.

  14. Interference of mobile phones and digitally enhanced cordless telecommunications mobile phones in renal scintigraphy.

    PubMed

    Stegmayr, Armin; Fessl, Benjamin; Hörtnagl, Richard; Marcadella, Michael; Perkhofer, Susanne

    2013-08-01

    The aim of the study was to assess the potential negative impact of cellular phones and digitally enhanced cordless telecommunication (DECT) devices on the quality of static and dynamic scintigraphy to avoid repeated testing in infant and teenage patients to protect them from unnecessary radiation exposure. The assessment was conducted by performing phantom measurements under real conditions. A functional renal-phantom acting as a pair of kidneys in dynamic scans was created. Data were collected using the setup of cellular phones and DECT phones placed in different positions in relation to a camera head to test the potential interference of cellular phones and DECT phones with the cameras. Cellular phones reproducibly interfered with the oldest type of gamma camera, which, because of its single-head specification, is the device most often used for renal examinations. Curves indicating the renal function were considerably disrupted; cellular phones as well as DECT phones showed a disturbance concerning static acquisition. Variable electromagnetic tolerance in different types of γ-cameras could be identified. Moreover, a straightforward, low-cost method of testing the susceptibility of equipment to interference caused by cellular phones and DECT phones was generated. Even though some departments use newer models of γ-cameras, which are less susceptible to electromagnetic interference, we recommend testing examination rooms to avoid any interference caused by cellular phones. The potential electromagnetic interference should be taken into account when the purchase of new sensitive medical equipment is being considered, not least because the technology of mobile communication is developing fast, which also means that different standards of wave bands will be issued in the future.

  15. All Fatigue is Not Created Equal: The Association of Fatigue and Its Subtypes on Pain Interference in Orofacial Pain.

    PubMed

    Boggero, Ian A; Rojas-Ramirez, Marcia V; Carlson, Charles R

    2017-03-01

    Fatigue is known to be a pathway through which depression, psychological distress, pain intensity, and sleep disturbance influence pain interference, but the independent effects of fatigue on pain interference after controlling for these variables remains unknown. In addition, no study to date has tested whether fatigue subtypes of general fatigue, mental fatigue, emotional fatigue, physical fatigue, or vigor differentially predict pain interference. The current study tested these associations using archival medical data of 2133 chronic orofacial pain patients, who completed a battery of psychological questionnaires at the time of their first appointment at an orofacial pain clinic. Hierarchical linear regression analysis revealed that after controlling for depression, psychological distress, sleep disturbance, pain intensity, and demographic variables, fatigue predicted higher pain interference (B=0.70, SE=0.17, P<0.001, η=0.01). Physical fatigue (B=1.70, SE=0.48, P<0.001, η=0.01) and vigor (B=-3.24, SE=0.47, P<0.001, η=0.03) were independently associated with pain interference after controlling for the aforementioned variables. The findings suggest that fatigue is an important independent predictor of pain interference and not merely a mediator. These findings also suggest that not all fatigue is created equal. Interventions aimed at reducing pain interference should target specific fatigue symptoms of physical fatigue and vigor. Future research investigating the independent associations of fatigue subtypes on pain outcomes may help clarify the nature of the interrelationships between pain and fatigue.

  16. Primary Salvage Survey of the Interference of Radiowaves Emitted by Smartphones on Medical Equipment.

    PubMed

    Takao, Hiroyuki; Yeh, Yu Chih; Arita, Hiroyuki; Obatake, Takumi; Sakano, Teppei; Kurihara, Minoru; Matsuki, Akira; Ishibashi, Toshihiro; Murayama, Yuichi

    2016-10-01

    Use of mobile phones has become a standard reality of everyday living for many people worldwide, including medical professionals, as data sharing has drastically helped to improve quality of care. This increase in the use of mobile phones within hospitals and medical facilities has raised concern regarding the influence of radio waves on medical equipment. Although comprehensive studies have examined the effects of electromagnetic interference from 2G wireless communication and personal digital cellular systems on medical equipment, similar studies on more recent wireless technologies such as Long Term Evolution, wideband code division multiple access, and high-speed uplink access have yet to be published. Numerous tests targeting current wireless technologies were conducted between December 2012 and March 2013 in an anechoic chamber, shielded from external radio signals, with a dipole antenna to assess the effects of smartphone interference on several types of medical equipment. The interference produced by electromagnetic waves across five frequency bands from four telecommunication standards was assessed on 49 components from 22 pieces of medical equipment. Of the 22 pieces of medical equipment tested, 13 experienced interference at maximum transmission power. In contrast, at minimum transmission power, the maximum interference distance varied from 2 to 5 cm for different wireless devices. Four machines were affected at the minimum transmission power, and the maximum interference distance at the maximum transmission power was 38 cm. Results show that the interference from smartphones on medical equipment is very controllable.

  17. The Role of Long-Term Memory in a Test of Visual Working Memory: Proactive Facilitation but no Proactive Interference

    PubMed Central

    Oberauer, Klaus; Awh, Edward; Sutterer, David W.

    2016-01-01

    We report four experiments examining whether associations in visual working memory are subject to proactive interference from long term memory (LTM). Following a long-term learning phase in which participants learned the colors of 120 unique objects, a working memory (WM) test was administered in which participants recalled the precise colors of three concrete objects in an array. Each array in the WM test consisted of one old (previously learned) object with a new color (old-mismatch), one old object with its old color (old-match), and one new object. Experiments 1 to 3 showed that WM performance was better in the old-match condition than in the new condition, reflecting a beneficial contribution from long term memory. In the old mismatch condition, participants sometimes reported colors associated with the relevant shape in LTM, but the probability of successful recall was equivalent to that in the new condition. Thus, information from LTM only intruded in the absence of reportable information in WM. Experiment 4 tested for, and failed to find, proactive interference from the preceding trial in the WM test: Performance in the old-mismatch condition, presenting an object from the preceding trial with a new color, was equal to performance with new objects. Experiment 5 showed that long-term memory for object-color associations is subject to proactive interference. We conclude that the exchange of information between LTM and WM appears to be controlled by a gating mechanism that protects the contents of WM from proactive interference but admits LTM information when it is useful. PMID:27685018

  18. Verbal Serial List Learning in Mild Cognitive Impairment: A Profile Analysis of Interference, Forgetting, and Errors

    PubMed Central

    Libon, David J.; Bondi, Mark W.; Price, Catherine C.; Lamar, Melissa; Eppig, Joel; Wambach, Denene M.; Nieves, Christine; Delano-Wood, Lisa; Giovannetti, Tania; Lippa, Carol; Kabasakalian, Anahid; Cosentino, Stephanie; Swenson, Rod; Penney, Dana L.

    2012-01-01

    Using cluster analysis Libon et al. (2010) found three verbal serial list-learning profiles involving delay memory test performance in patients with mild cognitive impairment (MCI). Amnesic MCI (aMCI) patients presented with low scores on delay free recall and recognition tests; mixed MCI (mxMCI) patients scored higher on recognition compared to delay free recall tests; and dysexecutive MCI (dMCI) patients generated relatively intact scores on both delay test conditions. The aim of the current research was to further characterize memory impairment in MCI by examining forgetting/savings, interference from a competing word list, intrusion errors/perseverations, intrusion word frequency, and recognition foils in these three statistically determined MCI groups compared to normal control (NC) participants. The aMCI patients exhibited little savings, generated more highly prototypic intrusion errors, and displayed indiscriminate responding to delayed recognition foils. The mxMCI patients exhibited higher saving scores, fewer and less prototypic intrusion errors, and selectively endorsed recognition foils from the interference list. dMCI patients also selectively endorsed recognition foils from the interference list but performed similarly compared to NC participants. These data suggest the existence of distinct memory impairments in MCI and caution against the routine use of a single memory test score to operationally define MCI. PMID:21880171

  19. Interference with olfactory memory by visual and verbal tasks.

    PubMed

    Annett, J M; Cook, N M; Leslie, J C

    1995-06-01

    It has been claimed that olfactory memory is distinct from memory in other modalities. This study investigated the effectiveness of visual and verbal tasks in interfering with olfactory memory and included methodological changes from other recent studies. Subjects were allocated to one of four experimental conditions involving interference tasks [no interference task; visual task; verbal task; visual-plus-verbal task] and presented 15 target odours. Either recognition of the odours or free recall of the odour names was tested on one occasion, either within 15 minutes of presentation or one week later. Recognition and recall performance both showed effects of interference of visual and verbal tasks but there was no effect for time of testing. While the results may be accommodated within a dual coding framework, further work is indicated to resolve theoretical issues relating to task complexity.

  20. Interference of medical contrast media on laboratory testing.

    PubMed

    Lippi, Giuseppe; Daves, Massimo; Mattiuzzi, Camilla

    2014-01-01

    The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iodinate contrast media include inappropriate gel barrier formation in blood tubes, the appearance of abnormal peaks in capillary zone electrophoresis of serum proteins, and a positive bias in assessment of cardiac troponin I with one immunoassay. The interference for gadolinium contrast agents include negative bias in calcium assessment with ortho-cresolphthalein colorimetric assays and occasional positive bias using some Arsenazo reagents, negative bias in measurement of angiotensin converting enzyme (ACE) and zinc (colorimetric assay), as well as positive bias in creatinine (Jaffe reaction), total iron binding capacity (TIBC, ferrozine method), magnesium (calmagite reagent) and selenium (mass spectrometry) measurement. Interference has also been reported in assessment of serum indices, pulse oximetry and methaemoglobin in samples of patients receiving Patent Blue V. Under several circumstances the interference was absent from manufacturer-supplied information and limited to certain type of reagents and/or analytes, so that local verification may be advisable to establish whether or not the test in use may be biased. Since the elimination half-life of these compounds is typically lower than 2 h, blood collection after this period may be a safer alternative in patients who have received contrast media for diagnostic purposes.

  1. Interference of medical contrast media on laboratory testing

    PubMed Central

    Lippi, Giuseppe; Daves, Massimo; Mattiuzzi, Camilla

    2014-01-01

    The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iodinate contrast media include inappropriate gel barrier formation in blood tubes, the appearance of abnormal peaks in capillary zone electrophoresis of serum proteins, and a positive bias in assessment of cardiac troponin I with one immunoassay. The interference for gadolinium contrast agents include negative bias in calcium assessment with ortho-cresolphthalein colorimetric assays and occasional positive bias using some Arsenazo reagents, negative bias in measurement of angiotensin converting enzyme (ACE) and zinc (colorimetric assay), as well as positive bias in creatinine (Jaffe reaction), total iron binding capacity (TIBC, ferrozine method), magnesium (calmagite reagent) and selenium (mass spectrometry) measurement. Interference has also been reported in assessment of serum indices, pulse oximetry and methaemoglobin in samples of patients receiving Patent Blue V. Under several circumstances the interference was absent from manufacturer-supplied information and limited to certain type of reagents and/or analytes, so that local verification may be advisable to establish whether or not the test in use may be biased. Since the elimination half-life of these compounds is typically lower than 2 h, blood collection after this period may be a safer alternative in patients who have received contrast media for diagnostic purposes. PMID:24627717

  2. Between-Trial Forgetting Due to Interference and Time in Motor Adaptation.

    PubMed

    Kim, Sungshin; Oh, Youngmin; Schweighofer, Nicolas

    2015-01-01

    Learning a motor task with temporally spaced presentations or with other tasks intermixed between presentations reduces performance during training, but can enhance retention post training. These two effects are known as the spacing and contextual interference effect, respectively. Here, we aimed at testing a unifying hypothesis of the spacing and contextual interference effects in visuomotor adaptation, according to which forgetting between trials due to either spaced presentations or interference by another task will promote between-trial forgetting, which will depress performance during acquisition, but will promote retention. We first performed an experiment with three visuomotor adaptation conditions: a short inter-trial-interval (ITI) condition (SHORT-ITI); a long ITI condition (LONG-ITI); and an alternating condition with two alternated opposite tasks (ALT), with the same single-task ITI as in LONG-ITI. In the SHORT-ITI condition, there was fastest increase in performance during training and largest immediate forgetting in the retention tests. In contrast, in the ALT condition, there was slowest increase in performance during training and little immediate forgetting in the retention tests. Compared to these two conditions, in the LONG-ITI, we found intermediate increase in performance during training and intermediate immediate forgetting. To account for these results, we fitted to the data six possible adaptation models with one or two time scales, and with interference in the fast, or in the slow, or in both time scales. Model comparison confirmed that two time scales and some degree of interferences in either time scale are needed to account for our experimental results. In summary, our results suggest that retention following adaptation is modulated by the degree of between-trial forgetting, which is due to time-based decay in single adaptation task and interferences in multiple adaptation tasks.

  3. A call for safer utilization of radio frequency identification in the e-health era.

    PubMed

    Liu, Chung-Feng; Hwang, Hsin-Ginn; Kuo, Kuang-Ming; Hung, Won-Fu

    2011-10-01

    The main purpose of this study was to investigate the perceptions of the electromagnetic interference (EMI) caused by radio frequency identification (RFID) with medical devices among hospitals as well as to call the attention of medical institutions to the development of RFID applications. A survey sponsored by the Department of Health of Taiwan was conducted and the target subjects were every hospital in Taiwan (486 in total). The survey topics included testing of RFID interference with medical devices and perceptions of safety issues of RFID. The main targets of the survey were the Chief Information Officers (CIOs) or the main person responsible for RFID systems in each hospital. Of the original 486 questionnaires mailed, 273 were returned. A return rate of 56.17% was obtained. The survey results revealed that only six hospitals had carried out tests on interference by RFID with medical devices, and the results of these tests indicated that RFID does not interfere with medical devices. A majority of hospitals understood that RFID may interfere with medical devices but did not think that this would seriously harm patients. The application of RFID in the healthcare industry is certainly promising; however, EMI issues must be appropriately handled. This study asserts that most hospitals do not understand or pay insufficient attention to the issue of RFID interference with patient safety or medical devices. In addition, most hospitals believe that the problem of RFID should be resolved by RFID vendors. Therefore, this study argues that medical institutions should develop more understanding of RFID issues and that more attention should be given to the potential problems of RFID interference when developing RFID applications.

  4. Aerodynamic heating to representative SRB and ET protuberances

    NASA Technical Reports Server (NTRS)

    Engel, C. D.; Lapointe, J. K.

    1979-01-01

    Heating data and data scaling methods which can be used on representative solid rocket booster and external tank (ET) protuberances are described. Topics covered include (1) ET geometry and heating points; (2) interference heating test data (51A); (3) heat transfer data from tests FH-15 and FH-16; (4) individual protuberance data; and (5) interference heating of paint data from test IH-42. A set of drawings of the ET moldline and protuberances is included.

  5. A method for testing the spectraltransmittance of infrared smoke interference

    NASA Astrophysics Data System (ADS)

    Lei, Hao; Zhang, Yazhou; Wang, Guangping; Wu, Jingli

    2018-02-01

    Infrared smoke is mainly used for shielding, blind, deception and recognition on the battlefield. The traditional shelter smoke is mainly placed in the friendly positions or positions between the friendly positions and enemy positions, to reduce the enemy observation post investigative capacity. The passive interference capability of the smoke depends on the infrared extinction ability of the smoke. The infrared transmittance test is an objective and accurate representation of the extinction ability of the smoke. In this paper, a method for testing the spectral transmittance of infrared smoke interference is introduced. The uncertainty of the measurement results is analyzed. The results show that this method can effectively obtain the spectral transmittance of the infrared smoke and uncertainty of the measurement is 7.16%, which can be effective for the smoke detection, smoke composition analysis, screening effect evaluation to provide test parameters support.

  6. Dynamic memory searches: Selective output interference for the memory of facts.

    PubMed

    Aue, William R; Criss, Amy H; Prince, Melissa A

    2015-12-01

    The benefits of testing on later memory performance are well documented; however, the manner in which testing harms memory performance is less well understood. This research is concerned with the finding that accuracy decreases over the course of testing, a phenomena termed "output interference" (OI). OI has primarily been investigated with episodic memory, but there is limited research investigating OI in measures of semantic memory (i.e., knowledge). In the current study, participants were twice tested for their knowledge of factual questions; they received corrective feedback during the first test. No OI was observed during the first test, when participants presumably searched semantic memory to answer the general-knowledge questions. During the second test, OI was observed. Conditional analyses of Test 2 performance revealed that OI was largely isolated to questions answered incorrectly during Test 1. These were questions for which participants needed to rely on recent experience (i.e., the feedback in episodic memory) to respond correctly. One possible explanation is that episodic memory is more susceptible to the sort of interference generated during testing (e.g., gradual changes in context, encoding/updating of items) relative to semantic memory. Alternative explanations are considered.

  7. The Effect of Reduction Gearing on Propeller-body Interference as Shown by Full-Scale Wind-Tunnel Tests

    NASA Technical Reports Server (NTRS)

    Weick, Fred E

    1931-01-01

    This report presents the results of full-scale tests made on a 10-foot 5-inch propeller on a geared J-5 engine and also on a similar 8-foot 11-inch propeller on a direct-drive J-5 engine. Each propeller was tested at two different pitch settings, and with a large and a small fuselage. The investigation was made in such a manner that the propeller-body interference factors were isolated, and it was found that, considering this interference only, the geared propellers had an appreciable advantage in propulsive efficiency, partially due to the larger diameter of the propellers with respect to the bodies, and partially because the geared propellers were located farther ahead of the engines and bodies.

  8. Residual interference and wind tunnel wall adaption

    NASA Technical Reports Server (NTRS)

    Mokry, Miroslav

    1989-01-01

    Measured flow variables near the test section boundaries, used to guide adjustments of the walls in adaptive wind tunnels, can also be used to quantify the residual interference. Because of a finite number of wall control devices (jacks, plenum compartments), the finite test section length, and the approximation character of adaptation algorithms, the unconfined flow conditions are not expected to be precisely attained even in the fully adapted stage. The procedures for the evaluation of residual wall interference are essentially the same as those used for assessing the correction in conventional, non-adaptive wind tunnels. Depending upon the number of flow variables utilized, one can speak of one- or two-variable methods; in two dimensions also of Schwarz- or Cauchy-type methods. The one-variable methods use the measured static pressure and normal velocity at the test section boundary, but do not require any model representation. This is clearly of an advantage for adaptive wall test section, which are often relatively small with respect to the test model, and for the variety of complex flows commonly encountered in wind tunnel testing. For test sections with flexible walls the normal component of velocity is given by the shape of the wall, adjusted for the displacement effect of its boundary layer. For ventilated test section walls it has to be measured by the Calspan pipes, laser Doppler velocimetry, or other appropriate techniques. The interface discontinuity method, also described, is a genuine residual interference assessment technique. It is specific to adaptive wall wind tunnels, where the computation results for the fictitious flow in the exterior of the test section are provided.

  9. 40 CFR 1065.369 - H2O, CO, and CO2 interference verification for photoacoustic alcohol analyzers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... compensation algorithms that utilize measurements of other gases to meet this interference verification, simultaneously conduct these other measurements to test the compensation algorithms during the analyzer...

  10. The role of test expectancy in the build-up of proactive interference in long-term memory.

    PubMed

    Weinstein, Yana; Gilmore, Adrian W; Szpunar, Karl K; McDermott, Kathleen B

    2014-07-01

    We examined the hypothesis that interpolated testing in a multiple list paradigm protects against proactive interference by sustaining test expectancy during encoding. In both experiments, recall on the last of 5 word lists was compared between 4 conditions: a tested group who had taken tests on all previous lists, an untested group who had not taken any tests on previous lists, and 2 other groups (one tested and the other untested) who were warned about the upcoming test prior to study of the fifth list. In both experiments, the untested/warned group performed significantly better than the untested/unwarned group on both correct recall and prior list intrusions but did not achieve the same recall accuracy as tested groups. In Experiment 2, an instruction manipulation check further narrowed the gap between the untested/warned group and the tested groups. In addition, we verified that a reduction in test expectancy indeed occurred in the untested group compared with the tested group by asking participants to indicate how likely they believed they were to receive a test on each studied list. These findings suggest that testing protects against proactive interference largely via attentional processes and/or more effective encoding. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  11. Another look at retroactive and proactive interference: a quantitative analysis of conversion processes.

    PubMed

    Blank, Hartmut

    2005-02-01

    Traditionally, the causes of interference phenomena were sought in "real" or "hard" memory processes such as unlearning, response competition, or inhibition, which serve to reduce the accessibility of target items. I propose an alternative approach which does not deny the influence of such processes but highlights a second, equally important, source of interference-the conversion (Tulving, 1983) of accessible memory information into memory performance. Conversion is conceived as a problem-solving-like activity in which the rememberer tries to find solutions to a memory task. Conversion-based interference effects are traced to different conversion processes in the experimental and control conditions of interference designs. I present a simple theoretical model that quantitatively predicts the resulting amount of interference. In two paired-associate learning experiments using two different types of memory tests, these predictions were corroborated. Relations of the present approach to traditional accounts of interference phenomena and implications for eyewitness testimony are discussed.

  12. Susceptibility to declarative memory interference is pronounced in primary insomnia.

    PubMed

    Griessenberger, Hermann; Heib, Dominik P J; Lechinger, Julia; Luketina, Nikolina; Petzka, Marit; Moeckel, Tina; Hoedlmoser, Kerstin; Schabus, Manuel

    2013-01-01

    Sleep has been shown to stabilize memory traces and to protect against competing interference in both the procedural and declarative memory domain. Here, we focused on an interference learning paradigm by testing patients with primary insomnia (N = 27) and healthy control subjects (N = 21). In two separate experimental nights with full polysomnography it was revealed that after morning interference procedural memory performance (using a finger tapping task) was not impaired in insomnia patients while declarative memory (word pair association) was decreased following interference. More specifically, we demonstrate robust associations of central sleep spindles (in N3) with motor memory susceptibility to interference as well as (cortically more widespread) fast spindle associations with declarative memory susceptibility. In general the results suggest that insufficient sleep quality does not necessarily show up in worse overnight consolidation in insomnia but may only become evident (in the declarative memory domain) when interference is imposed.

  13. Small Business Innovation Research (SBIR) Program. FY 1991 Program Solicitation 91.2

    DTIC Science & Technology

    1991-07-01

    Based Robotic Control Systems Technology A91-034 Passive Sensor Self- Interference Cancellation A91-035 High Performance Propelling Charges A91-036...laboratory tests. A91-034 TITLE: Passive Sensor Self- Interference Cancellation CATEGORY: Exploratory Development OBJECTIVE: Develop practical and effective...acoustic sensor to detect, classify, identify, and locate targets is ARMY 19 degraded by own-platform noise and local interference . Elementary

  14. The Effect of Colour-Word Interference on Children's Memory for Words.

    ERIC Educational Resources Information Center

    Malliet, Gineva M.

    The Stroop color-word test involves a conflict situation in which subjects are asked to say aloud the ink color used to print a color word on a card. Interference occurs when the ink color is in conflict with the color word, such as 'red' printed in green ink. On the other hand, little interference occurs when asked to name the color words…

  15. Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview.

    PubMed

    Floré, Katelijne M J; Delanghe, Joris R

    2009-01-01

    Current point-of-care testing (POCT) glucometers are based on various test principles. Two major method groups dominate the market: glucose oxidase-based systems and glucose dehydrogenase-based systems using pyrroloquinoline quinone (GDH-PQQ) as a cofactor. The GDH-PQQ-based glucometers are replacing the older glucose oxidase-based systems because of their lower sensitivity for oxygen. On the other hand, the GDH-PQQ test method results in falsely elevated blood glucose levels in peritoneal dialysis patients receiving solutions containing icodextrin (e.g., Extraneal; Baxter, Brussels, Belgium). Icodextrin is metabolized in the systemic circulation into different glucose polymers, but mainly maltose, which interferes with the GDH-PQQ-based method. Clinicians should be aware of this analytical interference. The POCT glucometers based on the GDH-PQQ method should preferably not be used in this high-risk population and POCT glucose results inconsistent with clinical suspicion of hypoglycemic coma should be retested with another testing system.

  16. Analysis of compounds that interfere with herpes simplex virus-host receptor interactions using surface plasmon resonance.

    PubMed

    Gopinath, Subash C B; Hayashi, Kyoko; Lee, Jung-Bum; Kamori, Akiko; Dong, Cai-Xia; Hayashi, Toshimitsu; Kumar, Penmetcha K R

    2013-11-05

    The entry of herpes simplex virus into host cells involves a complex series of events that require concerted inputs from multiple HSV glycoproteins. Among these glycoproteins, the gD protein of HSV-1 and HSV-2 plays an important role for host receptor binding and membrane fusion. In the present study, we evaluated the ability of different sulfated saccharides to interfere with gD-host receptor (HVEM) interactions using our recently reported molecular assay (Gopinath, S. C. B.; Hayashi, K.; Kumar, P. K. R. J. Virol. 2012, 86, 6732-6744). Initially, we tested the ability of heparan sulfate to interfere with the HVEM-HSV-1 gD interaction and found that heparan sulfate is able to interfere efficiently, with an apparent EC50 of 2.1 μM. In addition, we tested different synthetic sulfated polysaccharides and natural sulfated polysaccharides from an edible alga, Sargassum horneri , after fractionation into different sizes and sulfate and uronic acid contents. Six polysaccharides isolated from S. horneri were found to efficiently interfere with the HVEM-gD interaction. Three others caused moderate interference, and five caused weak interference. These results were confirmed with plaque assays, and good agreement was found with the results of the SPR assay for the identification of compounds that interfere with HVEM-HSV-1 gD binding. These studies suggest that our molecular assay based on surface plasmon resonance is not only useful for the analysis of viral-host protein interactions but is also applicable for the routine screening of compounds to identify those that interfere with the first step of viral entry, thus facilitating the rapid development of novel antiviral compounds that target HSV.

  17. Interference in Ballistic Motor Learning: Specificity and Role of Sensory Error Signals

    PubMed Central

    Lundbye-Jensen, Jesper; Petersen, Tue Hvass; Rothwell, John C.; Nielsen, Jens Bo

    2011-01-01

    Humans are capable of learning numerous motor skills, but newly acquired skills may be abolished by subsequent learning. Here we ask what factors determine whether interference occurs in motor learning. We speculated that interference requires competing processes of synaptic plasticity in overlapping circuits and predicted specificity. To test this, subjects learned a ballistic motor task. Interference was observed following subsequent learning of an accuracy-tracking task, but only if the competing task involved the same muscles and movement direction. Interference was not observed from a non-learning task suggesting that interference requires competing learning. Subsequent learning of the competing task 4 h after initial learning did not cause interference suggesting disruption of early motor memory consolidation as one possible mechanism underlying interference. Repeated transcranial magnetic stimulation (rTMS) of corticospinal motor output at intensities below movement threshold did not cause interference, whereas suprathreshold rTMS evoking motor responses and (re)afferent activation did. Finally, the experiments revealed that suprathreshold repetitive electrical stimulation of the agonist (but not antagonist) peripheral nerve caused interference. The present study is, to our knowledge, the first to demonstrate that peripheral nerve stimulation may cause interference. The finding underscores the importance of sensory feedback as error signals in motor learning. We conclude that interference requires competing plasticity in overlapping circuits. Interference is remarkably specific for circuits involved in a specific movement and it may relate to sensory error signals. PMID:21408054

  18. An experimental investigation of three dimensional low speed minimum interference wind tunnel for high lift wings

    NASA Technical Reports Server (NTRS)

    Shindo, S.; Joppa, R. G.

    1980-01-01

    As a means to achieve a minimum interference correction wind tunnel, a partially actively controlled test section was experimentally examined. A jet flapped wing with 0.91 m (36 in) span and R = 4.05 was used as a model to create moderately high lift coefficients. The partially controlled test section was simulated using an insert, a rectangular box 0.96 x 1.44 m (3.14 x 4.71 ft) open on both ends in the direction of the tunnel air flow, placed in the University of Washington Aeronautical Laboratories (UWAL) 2.44 x 3.66 m (8 x 12 ft) wind tunnel. A tail located three chords behind the wing was used to measure the downwash at the tail region. The experimental data indicates that, within the range of momentum coefficient examined, it appears to be unnecessary to actively control all four sides of the test section walls in order to achieve the near interference free flow field environment in a small wind tunnel. The remaining wall interference can be satisfactorily corrected by the vortex lattice method.

  19. Interference of Tail Surfaces and Wing and Fuselage from Tests of 17 Combinations in the N.A.C.A. Variable-Density Tunnel

    NASA Technical Reports Server (NTRS)

    Sherman, Albert

    1939-01-01

    An investigation of the interference associated with tail surfaces added to wing-fuselage combinations was included in the interference program in progress in the NACA variable-density tunnel. The results indicate that, in aerodynamically clean combinations, the increment to the high-speed drag can be estimated from section characteristics within useful limits of accuracy. The interference appears mainly as effects on the downwash angel and as losses in the tail. An interference burble, which markedly increases the glide-path angle and the stability in pitch before the actual stall, may be considered a means of obtaining satisfactory stalling characteristics for a complete combination.

  20. Potential for palivizumab interference with commercially available antibody-antigen based respiratory syncytial virus diagnostic assays.

    PubMed

    Deming, Damon J; Patel, Nita; McCarthy, Michael P; Mishra, Lalji; Shapiro, Alan M; Suzich, JoAnn A

    2013-10-01

    Palivizumab is a monoclonal antibody indicated for the prevention of serious lower respiratory tract disease caused by respiratory syncytial virus infection in infants. The potential for palivizumab to interfere with commercially available respiratory syncytial virus diagnostic tests was demonstrated. Negative test results in palivizumab-treated subjects should be interpreted with caution and confirmed by a nucleic acid amplification-based assay.

  1. The Role of Long-Term Memory in a Test of Visual Working Memory: Proactive Facilitation but No Proactive Interference

    ERIC Educational Resources Information Center

    Oberauer, Klaus; Awh, Edward; Sutterer, David W.

    2017-01-01

    We report 4 experiments examining whether associations in visual working memory are subject to proactive interference from long-term memory (LTM). Following a long-term learning phase in which participants learned the colors of 120 unique objects, a working memory (WM) test was administered in which participants recalled the precise colors of 3…

  2. Delayed Release from Proactive Interference with Meaningful Material: How Much Do We Remember After Reading Brief Prose Passages?

    ERIC Educational Resources Information Center

    Blumenthal, Gary B.; Robbins, Donald

    1977-01-01

    Three experiments were conducted, investigating the buildup of and the release from proactive interference, in which the stimulus materials were brief prose passages about specific topics. Each passage was followed by a multiple-choice test, and then a final test on all the passages read was given. Implications of the data for standardized tests…

  3. Proactive Interference and Directed Forgetting in Short-Term Motor Memory

    ERIC Educational Resources Information Center

    Burwitz, Leslie

    1974-01-01

    The present study was designed to test the effect of instructions to forget prior motor learning and the results were relevant to the understanding of short-term motor memory (STMM) proactive interference (PI). (Author/RK)

  4. The likelihood of acetone interference in breath alcohol measurement

    DOT National Transportation Integrated Search

    1985-09-01

    This report discusses the significance of possible interference of acetone in breath alcohol testing. The following dimensions were considered: 1) what levels of acetone concentration may appear on the breath; 2) what levels of acetone concentration ...

  5. Conductive interference in rapid transit signaling systems. volume 2. suggested test procedures

    DOT National Transportation Integrated Search

    1987-05-31

    Methods for detecting and quantifying the levels of conductive electromagnetic interference produced by solid state rapid transit propulsion equipment and for determining the susceptibility of signaling systems to these emissions are presented. These...

  6. Observation of Genuine Three-Photon Interference

    NASA Astrophysics Data System (ADS)

    Agne, Sascha; Kauten, Thomas; Jin, Jeongwan; Meyer-Scott, Evan; Salvail, Jeff Z.; Hamel, Deny R.; Resch, Kevin J.; Weihs, Gregor; Jennewein, Thomas

    2017-04-01

    Multiparticle quantum interference is critical for our understanding and exploitation of quantum information, and for fundamental tests of quantum mechanics. A remarkable example of multi-partite correlations is exhibited by the Greenberger-Horne-Zeilinger (GHZ) state. In a GHZ state, three particles are correlated while no pairwise correlation is found. The manifestation of these strong correlations in an interferometric setting has been studied theoretically since 1990 but no three-photon GHZ interferometer has been realized experimentally. Here we demonstrate three-photon interference that does not originate from two-photon or single photon interference. We observe phase-dependent variation of three-photon coincidences with (92.7 ±4.6 )% visibility in a generalized Franson interferometer using energy-time entangled photon triplets. The demonstration of these strong correlations in an interferometric setting provides new avenues for multiphoton interferometry, fundamental tests of quantum mechanics, and quantum information applications in higher dimensions.

  7. Allelopathic inhibition ofCynodon dactylon (L.) pers. and other plant species byEuphorbia prostrata L.

    PubMed

    Alsaadawi, I S; Sakeri, F A; Al-Dulaimy, S M

    1990-09-01

    Field observations indicated thatEuphorbia prostrata strongly interferes withCynodon dactylon (L.) Pers. Analysis of some physical and chemical soil factors indicated that competition was not the dominant factor of that interference. Soil collected from underE. prostrata stands was very inhibitory to seed germination and seeding growth of some of the test species including C.Dactylon. This suggests the presence of inhibitory compounds in soil ofE. prostrata stands. Subsequent experiments showed that aqueous extract, decaying residues, and root exudates ofE. prostrata were inhibitory to most of the test species including C.Dactylon. Thus, it appears that allelopathy is the major component of the interference, with competition probably accentuating its effect. It also was found that allelopathy is an important component of the interference byE. prostrata againstAmaranthus retroflexus, Medicago sativa, andGossypium hirsutum.

  8. A study of interferences in ozone UV and chemiluminescence monitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hudgens, E.E.; Kleindienst, T.E.; McElroy, F.F.

    A study was conducted to examine interferences and other measurement anomalies in chemiluminescence and ultraviolet ozone monitors. Previous results had show that there was a positive deviation in the chemiluminescence monitors and no direct interference with ultraviolet monitors due to the presence of water at non-condensing concentrations. The present study continues this effort, examining both potential positive and negative effects of moisture and other interferences on these monitors. Aromatic compounds and their oxidation products could potentially show a positive interference with ultraviolet monitors, and test measurements were made with aromatics such as toluene, benzaldehyde, and nitrotoluene to determine their possiblemore » retention in the ozone scrubber and their absorption in the cell as a function of the humidity. A detailed examination of the scrubbers used in ultraviolet ozone monitors has also been undertaken. Ozone scrubbers that have shown anomalous behavior in the field have been studied in various reduced-efficacy modes under controlled laboratory conditions. Longer term tests of unused scrubbers for possible ozone breakthrough under exposure to various simulated field conditions were initiated.« less

  9. Lipemia interferences in routine clinical biochemical tests.

    PubMed

    Calmarza, Pilar; Cordero, José

    2011-01-01

    Lipemic specimens are a common and frequent, but yet unresolved problem in clinical chemistry, and may produce significant interferences in the analytical results of different biochemical parameters. The aim of this study was to examine the effect of lipid removal using ultracentrifugation of lipemic samples, on some routine biochemistry parameters. Among all the samples obtained daily in our laboratory, the ones which were visibly muddy were selected and underwent to a process of ultracentrifugation, being determined a variety of biochemical tests before and after ultracentrifugation. A total of 110 samples were studied. We found significant differences in all the parameters studied except for total bilirubin, glucose, gamma-glutamyl transferase (GGT) and aspartate aminotransferase (AST). The greatest differences in the parameters analyzed were found in the concentration of alanine aminotransferase (ALT) (7.36%) and the smallest ones in the concentration of glucose (0.014%). Clinically significant interferences were found for phosphorus, creatinine, total protein and calcium. Lipemia causes clinically significant interferences for phosphorus, creatinine, total protein and calcium measurement and those interferences could be effectively removed by ultracentrifugation.

  10. Work-home interference among nurses: reciprocal relationships with job demands and health.

    PubMed

    van der Heijden, Beatrice I J M; Demerouti, Evangelia; Bakker, Arnold B

    2008-06-01

    This paper is a report of a study with three aims: (i) to investigate whether emotional, quantitative and physical demands have a causal, negative impact on nurses' health; (ii) to examine whether work-home interference can explain this effect, by playing a mediating role; and (iii) to test the so-called loss spiral hypothesis claiming that nurses' health problems lead to even higher job demands and more work-home interference over time. While many scholars have thought in terms of the stressor-->work-home interference-->strain model, the validity of a model that includes opposite pathways needs to be tested. A questionnaire was completed twice, with a 1-year time interval by 753 (63.4%) Registered Nurses working in hospitals, 183 (15.4%) working in nursing homes, and 251 (21.1%) working in home care institutions. The first measurement took place between October 2002 and June 2003. Our findings strongly support the idea of cross-lagged, reciprocal relationships between job demands and general health over time. The reciprocal model with work-home interference as an intervening variable (including reciprocal relationships between job demands, work-home interference and general health) showed a good fit to the data, and proved to be superior to both the causality and reversed causation models. The higher nurses' job demands, the higher is their level of work-home interference and the more likely is a general health deterioration over time, in turn giving rise to higher job demands and work-home interference, which may even aggravate the nurses' general health, and so on.

  11. The role of long-term memory in a test of visual working memory: Proactive facilitation but no proactive interference.

    PubMed

    Oberauer, Klaus; Awh, Edward; Sutterer, David W

    2017-01-01

    We report 4 experiments examining whether associations in visual working memory are subject to proactive interference from long-term memory (LTM). Following a long-term learning phase in which participants learned the colors of 120 unique objects, a working memory (WM) test was administered in which participants recalled the precise colors of 3 concrete objects in an array. Each array in the WM test consisted of 1 old (previously learned) object with a new color (old-mismatch), 1 old object with its old color (old-match), and 1 new object. Experiments 1 to 3 showed that WM performance was better in the old-match condition than in the new condition, reflecting a beneficial contribution from LTM. In the old-mismatch condition, participants sometimes reported colors associated with the relevant shape in LTM, but the probability of successful recall was equivalent to that in the new condition. Thus, information from LTM only intruded in the absence of reportable information in WM. Experiment 4 tested for, and failed to find, proactive interference from the preceding trial in the WM test: Performance in the old-mismatch condition, presenting an object from the preceding trial with a new color, was equal to performance with new objects. Experiment 5 showed that long-term memory for object-color associations is subject to proactive interference. We conclude that the exchange of information between LTM and WM appears to be controlled by a gating mechanism that protects the contents of WM from proactive interference but admits LTM information when it is useful. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  12. The protective effects of acute cardiovascular exercise on the interference of procedural memory.

    PubMed

    Jo, J S; Chen, J; Riechman, S; Roig, M; Wright, D L

    2018-04-10

    Numerous studies have reported a positive impact of acute exercise for procedural skill memory. Previous work has revealed this effect, but these findings are confounded by a potential contribution of a night of sleep to the reported exercise-mediated reduction in interference. Thus, it remains unclear if exposure to a brief bout of exercise can provide protection to a newly acquired motor memory. The primary objective of the present study was to examine if a single bout of moderate-intensity cardiovascular exercise after practice of a novel motor sequence reduces the susceptibility to retroactive interference. To address this shortcoming, 17 individuals in a control condition practiced a novel motor sequence that was followed by test after a 6-h wake-filled interval. A separate group of 17 individuals experienced practice with an interfering motor sequence 45 min after practice with the original sequence and were then administered test trials 6 h later. One additional group of 12 participants was exposed to an acute bout of exercise immediately after practice with the original motor sequence but prior to practice with the interfering motor sequence and the subsequent test. In comparison with the control condition, increased response times were revealed during the 6-h test for the individuals that were exposed to interference. The introduction of an acute bout of exercise between the practice of the two motor sequences produced a reduction in interference from practice with the second task at the time of test, however, this effect was not statistically significant. These data reinforce the hypothesis that while there may be a contribution from exercise to post-practice consolidation of procedural skills which is independent of sleep, sleep may interact with exercise to strengthen the effects of the latter on procedural memory.

  13. Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.

    PubMed

    Yu, Ningbo; Gassert, Roger; Riener, Robert

    2011-07-01

    Robotic and mechatronic devices that work compatibly with magnetic resonance imaging (MRI) are applied in diagnostic MRI, image-guided surgery, neurorehabilitation and neuroscience. MRI-compatible mechatronic systems must address the challenges imposed by the scanner's electromagnetic fields. We have developed objective quantitative evaluation criteria for device characteristics needed to formulate design guidelines that ensure MRI-compatibility based on safety, device functionality and image quality. The mutual interferences between an MRI system and mechatronic devices working in its vicinity are modeled and tested. For each interference, the involved components are listed, and a numerical measure for "MRI-compatibility" is proposed. These interferences are categorized into an MRI-compatibility matrix, with each element representing possible interactions between one part of the mechatronic system and one component of the electromagnetic fields. Based on this formulation, design principles for MRI-compatible mechatronic systems are proposed. Furthermore, test methods are developed to examine whether a mechatronic device indeed works without interferences within an MRI system. Finally, the proposed MRI-compatibility criteria and design guidelines have been applied to an actual design process that has been validated by the test procedures. Objective and quantitative MRI-compatibility measures for mechatronic and robotic devices have been established. Applying the proposed design principles, potential problems in safety, device functionality and image quality can be considered in the design phase to ensure that the mechatronic system will fulfill the MRI-compatibility criteria. New guidelines and test procedures for MRI instrument compatibility provide a rational basis for design and evaluation of mechatronic devices in various MRI applications. Designers can apply these criteria and use the tests, so that MRI-compatibility results can accrue to build an experiential database.

  14. A wall interference assessment/correction interface measurement system for the NASA/ARC 12-ft PWT

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Development of complex air vehicle configurations is placing increasing demands on wind tunnel testing capabilities. A major area of concern is wall induced interference. Recent developments in wall interference technology provide a means for assessing and correcting for the wall induced interference using information contained in the distribution of flow variables measured at, or near, the wall. The restoration of the NASA-ARC 12-ft pressure wind tunnel (PWT) provides an opportunity to incorporate a measurement system with which wall interference assessment/correction (WIAC) technology can be applied. In this first phase of the development of a WIAC system for the PWT, the design criteria for the placement and the geometry of wall static pressure orifices were determined with a three step approach. First, the operational environment of the PWT was analyzed as to the requirements for the WIAC system. Second, appropriate wall interference theories were evaluated against the requirements determined from the operational environment. Third, the flow about representative models in the PWT was calculated and, specifically, the pressure signatures at the location of the test section wall were obtained. The number of discrete pressure measurements and their locations were determined by curve fitting the pressure distribution through the discrete measurements and evaluating the resulting error.

  15. Binaural Interference: Quo Vadis?

    PubMed

    Jerger, James; Silman, Shlomo; Silverman, Carol; Emmer, Michele

    2017-04-01

    The reality of the phenomenon of binaural interference with speech recognition has been debated for two decades. Research has taken one of two avenues; group studies or case reports. In group studies, a sample of the elderly population is tested on speech recognition under three conditions; binaural, monaural right and monaural left. The aim is to determine the percent of the sample in which the expected outcome (binaural score-better-than-either-monaural score) is reversed (i.e., one of the monaural scores is better than the binaural score). This outcome has been commonly used to define binaural interference. The object of group studies is to answer the "how many" question, what is the prevalence of binaural interference in the sample. In case reports the binaural interference conclusion suggested by the speech recognition tests is not accepted until it has been corroborated by other independent diagnostic audiological measures. The aim is to attempt to determine the basis for the findings, to answer the "why" question. This article is at once tutorial, editorial and a case report. We argue that it is time to accept the reality of the phenomenon of binaural interference, to eschew group statistical approaches in search of an answer to the "how many" question, and to focus on individual case reports in search of an answer to the "why" question. American Academy of Audiology.

  16. When Learning Disturbs Memory – Temporal Profile of Retroactive Interference of Learning on Memory Formation

    PubMed Central

    Sosic-Vasic, Zrinka; Hille, Katrin; Kröner, Julia; Spitzer, Manfred; Kornmeier, Jürgen

    2018-01-01

    Introduction: Consolidation is defined as the time necessary for memory stabilization after learning. In the present study we focused on effects of interference during the first 12 consolidation minutes after learning. Participants had to learn a set of German – Japanese word pairs in an initial learning task and a different set of German – Japanese word pairs in a subsequent interference task. The interference task started in different experimental conditions at different time points (0, 3, 6, and 9 min) after the learning task and was followed by subsequent cued recall tests. In a control experiment the interference periods were replaced by rest periods without any interference. Results: The interference task decreased memory performance by up to 20%, with negative effects at all interference time points and large variability between participants concerning both the time point and the size of maximal interference. Further, fast learners seem to be more affected by interference than slow learners. Discussion: Our results indicate that the first 12 min after learning are highly important for memory consolidation, without a general pattern concerning the precise time point of maximal interference across individuals. This finding raises doubts about the generalized learning recipes and calls for individuality of learning schedules. PMID:29503621

  17. Interference of daratumumab with pretransfusion testing, mimicking a high-titer, low avidity like antibody.

    PubMed

    Lin, Mei-Hwa; Liu, Fei-Yun; Wang, Hsiu-Mien; Cho, Hsin-Ching; Lo, Shyh-Chyi

    2017-01-01

    Daratumumab is a monoclonal immunoglobulin against CD38 and has been approved for treating patients with refractory multiple myeloma. The presence of daratumumab in the sera can interfere with pretransfusion testing due to the weakly expression of CD38 on red cells. The reactivity could be mistaken as autoantibody (if autocontrol is positive) or alloantibody (if autocontrol is negative). We present a case that demonstrates daratumumab could mimic a high titer low avidity (HTLA) alloantibody. A 34-year-old male patient of refractory myeloma was recruited in phase three clinical trial involving daratumumab. Samples were sent to the blood bank for pretransfusion testing. Without knowledge of patient having used daratumumab, we mistook the reactivity in the patient's sera as an HTLA antibody due to the results of negative autocontrol and high titers of antibody activity. Antibody screen showed a panreactive pattern and the reactivity against screening cells was up to a titer of 1: 1240. The reactivity was weaker against cord cells than adult cells, became weaker against ZZAP-treated cells and became negative against DDT-treated cells. A discussion with attending physician finally revealed the reactivity was due to the interference caused by daratumumab. The case demonstrates good communication is essential in performing pretransfusion testing for patients receiving daratumumab and other new biological regimens that can interfere with compatibility test.

  18. Interference of daratumumab with pretransfusion testing, mimicking a high-titer, low avidity like antibody

    PubMed Central

    Lin, Mei-Hwa; Liu, Fei-Yun; Wang, Hsiu-Mien; Cho, Hsin-Ching; Lo, Shyh-Chyi

    2017-01-01

    Daratumumab is a monoclonal immunoglobulin against CD38 and has been approved for treating patients with refractory multiple myeloma. The presence of daratumumab in the sera can interfere with pretransfusion testing due to the weakly expression of CD38 on red cells. The reactivity could be mistaken as autoantibody (if autocontrol is positive) or alloantibody (if autocontrol is negative). We present a case that demonstrates daratumumab could mimic a high titer low avidity (HTLA) alloantibody. A 34-year-old male patient of refractory myeloma was recruited in phase three clinical trial involving daratumumab. Samples were sent to the blood bank for pretransfusion testing. Without knowledge of patient having used daratumumab, we mistook the reactivity in the patient's sera as an HTLA antibody due to the results of negative autocontrol and high titers of antibody activity. Antibody screen showed a panreactive pattern and the reactivity against screening cells was up to a titer of 1: 1240. The reactivity was weaker against cord cells than adult cells, became weaker against ZZAP-treated cells and became negative against DDT-treated cells. A discussion with attending physician finally revealed the reactivity was due to the interference caused by daratumumab. The case demonstrates good communication is essential in performing pretransfusion testing for patients receiving daratumumab and other new biological regimens that can interfere with compatibility test. PMID:28970695

  19. Obtaining tight bounds on higher-order interferences with a 5-path interferometer

    NASA Astrophysics Data System (ADS)

    Kauten, Thomas; Keil, Robert; Kaufmann, Thomas; Pressl, Benedikt; Brukner, Časlav; Weihs, Gregor

    2017-03-01

    Within the established theoretical framework of quantum mechanics, interference always occurs between pairs of paths through an interferometer. Higher order interferences with multiple constituents are excluded by Born’s rule and can only exist in generalized probabilistic theories. Thus, high-precision experiments searching for such higher order interferences are a powerful method to distinguish between quantum mechanics and more general theories. Here, we perform such a test in an optical multi-path interferometer, which avoids crucial systematic errors, has access to the entire phase space and is more stable than previous experiments. Our results are in accordance with quantum mechanics and rule out the existence of higher order interference terms in optical interferometry to an extent that is more than four orders of magnitude smaller than the expected pairwise interference, refining previous bounds by two orders of magnitude.

  20. Wall-interference assessment and corrections for transonic NACA 0012 airfoil data from various wind tunnels. M.S. Thesis - George Washington Univ., 1988

    NASA Technical Reports Server (NTRS)

    Green, Lawrence L.; Newman, Perry A.

    1991-01-01

    A nonlinear, four wall, post-test wall interference assessment/correction (WIAC) code was developed for transonic airfoil data from solid wall wind tunnels with flexibly adaptable top and bottom walls. The WIAC code was applied over a broad range of test conditions to four sets of NACA 0012 airfoil data, from two different adaptive wall wind tunnels. The data include many test points for fully adapted walls, as well as numerous partially adapted and unadapted test points, which together represent many different model/tunnel configurations and possible wall interference effects. Small corrections to the measured Mach numbers and angles of attack were obtained from the WIAC code even for fully adapted data; these corrections generally improve the correlation among the various sets of airfoil data and simultaneously improve the correlation of the data with calculations for a 2-D, free air, Navier-Stokes code. The WIAC corrections for airfoil data taken in fully adapted wall test sections are shown to be significantly smaller than those for comparable airfoil data from straight, slotted wall test sections. This indicates, as expected, a lesser degree of wall interference in the adapted wall tunnels relative to the slotted wall tunnels. Application of the WIAC code to this data was, however, somewhat more difficult and time consuming than initially expected from similar previous experience with WIAC applications to slotted wall data.

  1. Different Loci of Semantic Interference in Picture Naming vs. Word-Picture Matching Tasks.

    PubMed

    Harvey, Denise Y; Schnur, Tatiana T

    2016-01-01

    Naming pictures and matching words to pictures belonging to the same semantic category impairs performance relative to when stimuli come from different semantic categories (i.e., semantic interference). Despite similar semantic interference phenomena in both picture naming and word-picture matching tasks, the locus of interference has been attributed to different levels of the language system - lexical in naming and semantic in word-picture matching. Although both tasks involve access to shared semantic representations, the extent to which interference originates and/or has its locus at a shared level remains unclear, as these effects are often investigated in isolation. We manipulated semantic context in cyclical picture naming and word-picture matching tasks, and tested whether factors tapping semantic-level (generalization of interference to novel category items) and lexical-level processes (interactions with lexical frequency) affected the magnitude of interference, while also assessing whether interference occurs at a shared processing level(s) (transfer of interference across tasks). We found that semantic interference in naming was sensitive to both semantic- and lexical-level processes (i.e., larger interference for novel vs. old and low- vs. high-frequency stimuli), consistent with a semantically mediated lexical locus. Interference in word-picture matching exhibited stable interference for old and novel stimuli and did not interact with lexical frequency. Further, interference transferred from word-picture matching to naming. Together, these experiments provide evidence to suggest that semantic interference in both tasks originates at a shared processing stage (presumably at the semantic level), but that it exerts its effect at different loci when naming pictures vs. matching words to pictures.

  2. Different Loci of Semantic Interference in Picture Naming vs. Word-Picture Matching Tasks

    PubMed Central

    Harvey, Denise Y.; Schnur, Tatiana T.

    2016-01-01

    Naming pictures and matching words to pictures belonging to the same semantic category impairs performance relative to when stimuli come from different semantic categories (i.e., semantic interference). Despite similar semantic interference phenomena in both picture naming and word-picture matching tasks, the locus of interference has been attributed to different levels of the language system – lexical in naming and semantic in word-picture matching. Although both tasks involve access to shared semantic representations, the extent to which interference originates and/or has its locus at a shared level remains unclear, as these effects are often investigated in isolation. We manipulated semantic context in cyclical picture naming and word-picture matching tasks, and tested whether factors tapping semantic-level (generalization of interference to novel category items) and lexical-level processes (interactions with lexical frequency) affected the magnitude of interference, while also assessing whether interference occurs at a shared processing level(s) (transfer of interference across tasks). We found that semantic interference in naming was sensitive to both semantic- and lexical-level processes (i.e., larger interference for novel vs. old and low- vs. high-frequency stimuli), consistent with a semantically mediated lexical locus. Interference in word-picture matching exhibited stable interference for old and novel stimuli and did not interact with lexical frequency. Further, interference transferred from word-picture matching to naming. Together, these experiments provide evidence to suggest that semantic interference in both tasks originates at a shared processing stage (presumably at the semantic level), but that it exerts its effect at different loci when naming pictures vs. matching words to pictures. PMID:27242621

  3. The effect of screw taper on interference fit during load to failure at the soft tissue/bone interface.

    PubMed

    Mann, Charles J; Costi, John J; Stanley, Richard M; Dobson, Peter J

    2005-10-01

    The effect of screw geometry on the pullout strength of an anterior cruciate ligament reconstruction is well documented. The effect of a truly tapered screw has not been previously investigated. Thirty bovine knees in right and left knee pairs were collected. Superficial digital flexors from the hind legs of sheep were harvested to form a quadruple tendon graft. For each knee pair, one tendon graft was fixed using a tapered screw (n=15) and the other with a non-tapered screw (n=15). Interference screws were manufactured from stainless steel, and apart from the tapered or non-tapered profile were identical. The screws were inserted into a tibial tunnel already containing the tendon graft. The interference fit was tested by extensile load to failure tests. The insertion torque of the screws and first sign of load to failure (by pullout) of the interference fit were recorded. Results were analysed using paired t-tests. The results indicated that tapered screws have significantly higher resistance to interference failure (p=0.007) and insertion torque (p<0.001) than non-tapered screws. The improved biomechanical performance of tapered screws demonstrated in this study may translate into superior clinical results, particularly at the tibial attachment of hamstring anterior cruciate ligament reconstruction, and also of hamstring fixation to the medial femoral condyle for patella instability.

  4. Electromagnetic Interference Tests

    DTIC Science & Technology

    1994-05-31

    for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (300 kHz - 100 GHz), American National Standards Institute...Respect to Human Exposure to Radio Frequency Electromagnetic Fields (300 kHz - 100 GHz), American National Standards Institute, C95.1-1982, 30 July 1980...II il~l I!I 11 lll i 13. ABSTkACT (Waxlrnun 200woruh) This TOP is a general guideline for electromagnetic interference testing of electronic

  5. Fingerprint extraction from interference destruction terahertz spectrum.

    PubMed

    Xiong, Wei; Shen, Jingling

    2010-10-11

    In this paper, periodic peaks in a terahertz absorption spectrum are confirmed to be induced from interference effects. Theoretically, we explained the periodic peaks and calculated the locations of them. Accordingly, a technique was suggested, with which the interference peaks in a terahertz spectrum can be eliminated and therefore a real terahertz absorption spectrum can be obtained. Experimentally, a sample, Methamphetamine, was investigated and its terahertz fingerprint was successfully extracted from its interference destruction spectrum. This technique is useful in getting samples' terahertz fingerprint spectra, and furthermore provides a fast nondestructive testing method using a large size terahertz beam to identify materials.

  6. Stress and binge drinking: A toxic combination for the teenage brain.

    PubMed

    Goldstein, Aaron; Déry, Nicolas; Pilgrim, Malcolm; Ioan, Miruna; Becker, Suzanna

    2016-09-01

    Young adult university students frequently binge on alcohol and have high stress levels. Based on findings in rodents, we predicted that heavy current alcohol use and elevated stress and depression scores would be associated with deficits on high interference memory tasks, while early onset, prolonged binge patterns would lead to broader cognitive deficits on tests of associative encoding and executive functions. We developed the Concentration Memory Task, a novel computerized version of the Concentration card game with a high degree of interference. We found that young adults with elevated stress, depression, and alcohol consumption scores were impaired in the Concentration Memory Task. We also analyzed data from a previous study, and found that higher alcohol consumption scores were associated with impaired performance on another high interference memory task, based on Kirwan and Stark's Mnemonic Similarity Test. On the other hand, adolescent onset of binge drinking predicted poorer performance on broader range of memory tests, including a more systematic test of spatial recognition memory, and an associative learning task. Our results are broadly consistent with findings in rodents that acute alcohol and stress exposure suppress neurogenesis in the adult hippocampus, which in turn impairs performance in high interference memory tasks, while adolescent onset binge drinking causes more extensive brain damage and cognitive deficits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Report of the EMI Testing of the Johnson Noise Thermometry System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Britton Jr., Charles L.; Roberts, Michael

    This report summarizes the Electromagnetic Interference (EMI) testing of the Johnson Noise Thermometry System developed at ORNL. The EMI performance is very important for Johnson Noise Thermometry because it requires accurate measurement of a very small noise signal that is amplified 10,000 times. Any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Testing is therefore very important in determining the effects of these external noise sources. Results from testing in several environments with various sources of EMI are presented here.

  8. An active interference projector for the electro-optical test facility

    NASA Astrophysics Data System (ADS)

    Crowe, D. G.; Nowak, T. M.

    1980-09-01

    A projection system is described which can simulate emissions from flares, muzzle-flashes, shellbursts, and other emissive agents which may degrade the performance of electro-optical systems in the 0.5-15 micron spectral range. The simulation capability obtained will allow the apparent radiance and temporal characteristics of muzzleflashes and shellbursts to be mimicked at simulated ranges as close as 23 m within the Electro-Optical Test Facility. This demonstrates that tests of electro-optical system performance in the presence of interferers can be performed under laboratory conditions with higher repeatability and lower cost than field tests.

  9. Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods.

    PubMed

    Monneret, Denis; Mestari, Fouzi; Atlan, Gregory; Corlouer, Camille; Ramani, Zo; Jaffre, Jeremy; Dever, Sylvie; Fressart, Veronique; Alkouri, Rana; Lamari, Foudil; Devilliers, Catherine; Imbert-Bismut, Françoise; Bonnefont-Rousselot, Dominique

    2015-04-01

    To determine the hemolysis interference on biochemical tests and immunoassays performed on Roche Diagnostics analyzers, according to different maximum allowable limits. Heparinized plasma and serum pools, free of interferences, were overloaded by increasing amounts of a hemoglobin-titrated hemolysate. This interference was evaluated for 45 analytes using Modular(®) and Cobas(®) analyzers. For each parameter, the hemolysis index (HI) corresponding to the traditional ± 10% change of concentrations from baseline (± 10%Δ) was determined, as well as those corresponding to the analytical change limit (ACL), and to the reference change value (RCV). Then, the relative frequencies distribution (% RFD) of hemolyzed tests performed in a hospital laboratory over a 25-day period were established for each HI as allowable limit. Considering the ± 10%Δ, the analyte concentrations enhanced by hemolysis were: Lactate dehydrogenase (LDH), aspartate aminotransferase (AST), folate, potassium, creatine kinase, phosphorus, iron, alanine aminotransferase, lipase, magnesium and triglycerides, decreasingly. The analyte concentrations decreased by hemolysis were: Haptoglobin, high-sensitive troponin T and alkaline phosphatase. Over the 25-day period, the % RFD of tests impacted more than 10%Δ by hemolysis were < 7% for LDH; < 5% for AST, folates and iron; and < 1% for the other analytes. Considering the ACL, HI were lower, giving % RFD substantially increased for many analytes, whereas only four analytes remain sensitive to hemolysis when considering RCV. This study proposes new HI based on different allowable limits, and can therefore serve as a starting point for future harmonization of hemolysis interference evaluation needed in routine laboratory practice.

  10. Interference and negative priming effects in adolescents with attention deficit hyperactivity disorder.

    PubMed

    Pritchard, Verena E; Neumann, Ewald; Rucklidge, Julia J

    2007-01-01

    Three visual selective attention tasks were used to measure potential differences in susceptibility to interference and inhibitory cognitive control processes in 16 adolescents diagnosed with attention deficit hyperactivity disorder (ADHD) and 45 similar-aged controls. Susceptibility to interference was assessed using the Stroop color and word naming test. Efficiency of distractor inhibition was assessed in two conceptual negative priming tasks. The majority of studies in this area indicate that people with ADHD demonstrate higher levels of interference and lower negative priming effects in comparison with age-matched peers. However, we found that although the ADHD group was consistently slower to name target stimuli than the control group, there were no differences in interference or negative priming between the two groups.

  11. Interference of Tail Surfaces and Wing and Fuselage from Tests of 17 Combinations in the N.A.C.A. Variable-Density Tunnel

    NASA Technical Reports Server (NTRS)

    Sherman, Albert

    1939-01-01

    An investigation of the interference associated with tail surfaces added to wing-fuselage combinations was included in the interference program in progress in the NACA variable-density tunnel. The results indicate that, in aerodynamically clean combinations, the increment of the high-speed drag can be estimated from section characteristics within useful limits of accuracy. The interference appears mainly as effects on the downwash angle and as losses in the tail effectiveness and varies with the geometry of the combination. An interference burble, which markedly increases the glide-path angle and the stability in pitch before the actual stall, may be considered a means of obtaining satisfactory stalling characteristics for complete combination.

  12. Transfer Failure and Proactive Interference in Short-Term Memory

    ERIC Educational Resources Information Center

    Ellis, John A.

    1977-01-01

    Two experiments tested the hypothesis that proactive interference over a series of Brown-Peterson trials results from a combination of the subject's failure to transfer information to a permanent memory state and failure to retrieve information from permanent memory. (Editor)

  13. Contextual Interference Effects in Learning Three Badminton Serves.

    ERIC Educational Resources Information Center

    Goode, Sinah; Magill, Richard A.

    1986-01-01

    This study was made to validate results obtained in laboratory research. Thirty female students learned three badminton serves in either a low, mixed, or high interference practice schedule and were given a retention and transfer test. Results are discussed. (Author/MT)

  14. Effects of conflicting auditory stimuli on color-word interference and arousal.

    DOT National Transportation Integrated Search

    1971-03-01

    Although air traffic controllers are often required to perform in the presence of distracting stimuli, no adequate measures of distraction susceptibility exist. In the study, 50 male subjects were tested to determine whether the interference effect p...

  15. Multipath interference test method using synthesized chirped signal from directly modulated DFB-LD with digital-signal-processing technique.

    PubMed

    Aida, Kazuo; Sugie, Toshihiko

    2011-12-12

    We propose a method of testing transmission fiber lines and distributed amplifiers. Multipath interference (MPI) is detected as a beat spectrum between a multipath signal and a direct signal using a synthesized chirped test signal with lightwave frequencies of f(1) and f(2) periodically emitted from a distributed feedback laser diode (DFB-LD). This chirped test pulse is generated using a directly modulated DFB-LD with a drive signal calculated using a digital signal processing technique (DSP). A receiver consisting of a photodiode and an electrical spectrum analyzer (ESA) detects a baseband power spectrum peak appearing at the frequency of the test signal frequency deviation (f(1)-f(2)) as a beat spectrum of self-heterodyne detection. Multipath interference is converted from the spectrum peak power. This method improved the minimum detectable MPI to as low as -78 dB. We discuss the detailed design and performance of the proposed test method, including a DFB-LD drive signal calculation algorithm with DSP for synthesis of the chirped test signal and experiments on single-mode fibers with discrete reflections. © 2011 Optical Society of America

  16. Semantic interference in picture naming during dual-task performance does not vary with reading ability.

    PubMed

    Piai, Vitória; Roelofs, Ardi; Roete, Ingeborg

    2015-01-01

    Previous dual-task studies examining the locus of semantic interference of distractor words in picture naming have obtained diverging results. In these studies, participants manually responded to tones and named pictures while ignoring distractor words (picture-word interference, PWI) with varying stimulus onset asynchrony (SOA) between tone and PWI stimulus. Whereas some studies observed no semantic interference at short SOAs, other studies observed effects of similar magnitude at short and long SOAs. The absence of semantic interference in some studies may perhaps be due to better reading skill of participants in these than in the other studies. According to such a reading-ability account, participants' reading skill should be predictive of the magnitude of their interference effect at short SOAs. To test this account, we conducted a dual-task study with tone discrimination and PWI tasks and measured participants' reading ability. The semantic interference effect was of similar magnitude at both short and long SOAs. Participants' reading ability was predictive of their naming speed but not of their semantic interference effect, contrary to the reading ability account. We conclude that the magnitude of semantic interference in picture naming during dual-task performance does not depend on reading skill.

  17. Internal Friction And Instabilities Of Rotors

    NASA Technical Reports Server (NTRS)

    Walton, J.; Artiles, A.; Lund, J.; Dill, J.; Zorzi, E.

    1992-01-01

    Report describes study of effects of internal friction on dynamics of rotors prompted by concern over instabilities in rotors of turbomachines. Theoretical and experimental studies described. Theoretical involved development of nonlinear mathematical models of internal friction in three joints found in turbomachinery - axial splines, Curvic(TM) splines, and interference fits between smooth cylindrical surfaces. Experimental included traction tests to determine the coefficients of friction of rotor alloys at various temperatures, bending-mode-vibration tests of shafts equipped with various joints and rotordynamic tests of shafts with axial-spline and interference-fit joints.

  18. Effect of a High-Intensity, Intermittent-Exercise Protocol on Neurocognitive Function in Healthy Adults: Implications for Return-to-Play Management After Sport-Related Concussion.

    PubMed

    Whyte, Enda F; Gibbons, Nicola; Kerr, Grainne; Moran, Kieran A

    2015-12-03

    Determination of return to play (RTP) after sport-related concussion (SRC) is critical given the potential consequences of premature RTP. Current RTP guidelines may not identify persistent exercise-induced neurocognitive deficits in asymptomatic athletes after SRC. Therefore, postexercise neurocognitive testing has been recommended to further inform RTP determination. To implement this recommendation, the effect of exercise on neurocognitive function in healthy athletes should be understood. To examine the acute effects of a high-intensity intermittent-exercise protocol (HIIP) on neurocognitive function assessed by the Symbol Digits Modality Test (SDMT) and Stroop Interference Test. Cohort study. University laboratory. 40 healthy male athletes (age 21.25 ± 1.29 y, education 16.95 ± 1.37 y). Each participant completed the SDMT and Stroop Interference Test at baseline and after random allocation to a condition (HIIP vs control). A mixed between-within-subjects ANOVA assessed time- (pre- vs postcondition) -by-condition interaction effects. SDMT and Stroop Interference Test scores. There was a significant time-by-condition interaction effect (P < .001, η2 = .364) for the Stroop Interference Test scores, indicating that the HIIP group scored significantly lower (56.05 ± 9.34) postcondition than the control group (66.39 ± 19.6). There was no significant time-by-condition effect (P = .997, η2 < .001) for the SDMT, indicating that there was no difference between SDMT scores for the HIIP and control groups (59.95 ± 10.7 vs 58.56 ± 14.02). In healthy athletes, the HIIP results in a reduction in neurocognitive function as assessed by the Stroop Interference Test, with no effect on function as assessed by the SDMT. Testing should also be considered after high-intensity exercise in determining RTP decisions for athletes after SRC in conjunction with the existing recommended RTP protocol. These results may provide an initial reference point for future research investigating the effects of an HIIP on the neurocognitive function of athletes recovering from SRC.

  19. Revisiting the co-existence of Attention-Deficit/Hyperactivity Disorder and Chronic Tic Disorder in childhood-The case of colour discrimination, sustained attention and interference control.

    PubMed

    Uebel-von Sandersleben, Henrik; Albrecht, Björn; Rothenberger, Aribert; Fillmer-Heise, Anke; Roessner, Veit; Sergeant, Joseph; Tannock, Rosemary; Banaschewski, Tobias

    2017-01-01

    Attention Deficit / Hyperactivity Disorder (ADHD) and Chronic Tic Disorder (CTD) are two common and frequently co-existing disorders, probably following an additive model. But this is not yet clear for the basic sensory function of colour processing sensitive to dopaminergic functioning in the retina and higher cognitive functions like attention and interference control. The latter two reflect important aspects for psychoeducation and behavioural treatment approaches. Colour discrimination using the Farnsworth-Munsell 100-hue Test, sustained attention during the Frankfurt Attention Inventory (FAIR), and interference liability during Colour- and Counting-Stroop-Tests were assessed to further clarify the cognitive profile of the co-existence of ADHD and CTD. Altogether 69 children were classified into four groups: ADHD (N = 14), CTD (N = 20), ADHD+CTD (N = 20) and healthy Controls (N = 15) and compared in cognitive functioning in a 2×2-factorial statistical model. Difficulties with colour discrimination were associated with both ADHD and CTD factors following an additive model, but in ADHD these difficulties tended to be more pronounced on the blue-yellow axis. Attention problems were characteristic for ADHD but not CTD. Interference load was significant in both Colour- and Counting-Stroop-Tests and unrelated to colour discrimination. Compared to Controls, interference load in the Colour-Stroop was higher in pure ADHD and in pure CTD, but not in ADHD+CTD, following a sub-additive model. In contrast, interference load in the Counting-Stroop did not reveal ADHD or CTD effects. The co-existence of ADHD and CTD is characterized by additive as well as sub-additive performance impairments, suggesting that their co-existence may show simple additive characteristics of both disorders or a more complex interaction, depending on demand. The equivocal findings on interference control may indicate limited validity of the Stroop-Paradigm for clinical assessments.

  20. Interference studies with two hospital-grade and two home-grade glucose meters.

    PubMed

    Lyon, Martha E; Baskin, Leland B; Braakman, Sandy; Presti, Steven; Dubois, Jeffrey; Shirey, Terry

    2009-10-01

    Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America. Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations. Day-to-day precision was evaluated using aqueous control materials supplied by each vendor. Common interferences, including hematocrit, maltose, and ascorbate, were tested alone and in combination with one another on each of the four glucose testing devices at three blood glucose concentrations. Within-run precision for all glucose meters was <5% except for the FreeStyle (up to 7.6%). Between-day precision was <6% for all glucose meters. Ascorbate caused differences (percentage change from a sample without added interfering substances) of >5% with pyrroloquinolinequinone (PQQ)-glucose dehydrogenase-based technologies (Aviva and Freestyle) and the glucose oxidase-based Flexx meter. Maltose strongly affected the PQQ-glucose dehydrogenase-based meter systems. When combinations of interferences (ascorbate, maltose, and hematocrit mixtures) were tested, the extent of the interference was up to 193% (Aviva), 179% (FreeStyle), 25.1% (Flexx), and 5.9% (StatStrip). The interference was most pronounced at low glucose (3.9-4.4 mmol/L). All evaluated glucose meter systems demonstrated varying degrees of interference by hematocrit, ascorbate, and maltose mixtures. PQQ-glucose dehydrogenase-based technologies showed greater susceptibility than glucose oxidase-based systems. However, the modified glucose oxidase-based amperometric method (Nova StatStrip) was less affected in comparison with the glucose oxidase-based photometric method (LifeScan SureStep Flexx).

  1. Revisiting the co-existence of Attention-Deficit/Hyperactivity Disorder and Chronic Tic Disorder in childhood—The case of colour discrimination, sustained attention and interference control

    PubMed Central

    Rothenberger, Aribert; Fillmer-Heise, Anke; Roessner, Veit; Sergeant, Joseph; Tannock, Rosemary; Banaschewski, Tobias

    2017-01-01

    Objective Attention Deficit / Hyperactivity Disorder (ADHD) and Chronic Tic Disorder (CTD) are two common and frequently co-existing disorders, probably following an additive model. But this is not yet clear for the basic sensory function of colour processing sensitive to dopaminergic functioning in the retina and higher cognitive functions like attention and interference control. The latter two reflect important aspects for psychoeducation and behavioural treatment approaches. Methods Colour discrimination using the Farnsworth-Munsell 100-hue Test, sustained attention during the Frankfurt Attention Inventory (FAIR), and interference liability during Colour- and Counting-Stroop-Tests were assessed to further clarify the cognitive profile of the co-existence of ADHD and CTD. Altogether 69 children were classified into four groups: ADHD (N = 14), CTD (N = 20), ADHD+CTD (N = 20) and healthy Controls (N = 15) and compared in cognitive functioning in a 2×2-factorial statistical model. Results Difficulties with colour discrimination were associated with both ADHD and CTD factors following an additive model, but in ADHD these difficulties tended to be more pronounced on the blue-yellow axis. Attention problems were characteristic for ADHD but not CTD. Interference load was significant in both Colour- and Counting-Stroop-Tests and unrelated to colour discrimination. Compared to Controls, interference load in the Colour-Stroop was higher in pure ADHD and in pure CTD, but not in ADHD+CTD, following a sub-additive model. In contrast, interference load in the Counting-Stroop did not reveal ADHD or CTD effects. Conclusion The co-existence of ADHD and CTD is characterized by additive as well as sub-additive performance impairments, suggesting that their co-existence may show simple additive characteristics of both disorders or a more complex interaction, depending on demand. The equivocal findings on interference control may indicate limited validity of the Stroop-Paradigm for clinical assessments. PMID:28594866

  2. The interplay of parental support, parental pressure and test anxiety--Gender differences in adolescents.

    PubMed

    Ringeisen, Tobias; Raufelder, Diana

    2015-12-01

    This study examined gender-specific relationships between adolescents' perceptions of school-related support/pressure from their parents and test anxiety. A sample of German students (N = 845; Mage = 15.32; SD = .49) completed questionnaires that measured their perceived parental support/pressure (for mother and father separately) as well as the four main components of test anxiety (worry, interference, lack of confidence, and emotionality). Gender-specific relations were identified using multigroup structural equation modeling: For girls, perceived maternal pressure was positively associated with emotionality and interference; for boys, perceived father pressure and father support were positively associated with interference and worry, respectively. For both genders, perceived mother pressure and support were related to lack of confidence. Our findings suggest that adolescents' perceptions of maternal attitudes are associated with students' self-confidence irrespective of the child's gender, whereas the remaining facets of test anxiety follow same-sex trajectories between perceived parental attitudes and adolescents' test anxiety. Copyright © 2015 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  3. Hazard Monitoring in a Spectrum-Challenged Future: US Department of Transportation Adjacent Band Compatibility Assessment of Interference on High-Precision GNSS Receivers

    NASA Astrophysics Data System (ADS)

    Blume, F.; Berglund, H. T.

    2016-12-01

    In 2012 the Federal Communications Commission (FCC) reversed its decision to allow communications company LightSquared to use GPS-adjacent spectrum for a ground based network after testing demonstrated harmful interference to GPS receivers. Now rebranded as Ligado, they have submitted modified application to use a smaller portion of the L-band spectrum at much lower power. Many GPS community stakeholders, including the hazard monitoring and EEW communities remain concerned that Ligado's proposed use could still cause harmful interference, causing signal degradation, real-time positioning errors, and total failure of GNSS hardware in widespread use in hazard monitoring networks. The Department of Transportation (DoT) has conducted hardware tests to determine adjacent-band transmitter power limit criteria that would prevent harmful interference from Ligado's operations. We present preliminary results produced from the data collected by the three UNAVCO receiver types tested: Trimble NetRS, Trimble NetR9, and Septentrio PolaRx5. In the first round of testing, simulated GNSS signals were broadcast in an anechoic chamber (pictured below) while interfering signals are broadcast simultaneously with varying amplitude and frequency. The older GPS-only NetRS receiver showed smaller reductions in SNR at frequencies adjacent to GPS L1 as compared to the other receivers, suggesting narrower L1 filter bandwidth in the RF frontend. The NetR9 showed greater decreases in observed SNR in the 1615 to 1625 MHz range when compared to the other two receivers. This suggests that the NetR9's L1 filter bandwidth has been increased to accommodate GNSS signals. Linearity tests were conducted to better relate SNR measurements between receiver types. The PolaRx5 receiver showed less SNR variation between tracking channels than both Trimble receivers. Our results show the power levels at which adjacent-band interference begins degrading receiver performance and eventually disables tracking. As the demand for spectrum for mobile applications increases, operators of hazard networks may need to consider the impact of RF interference on data quality and continuity. UNAVCO's participation ensures that our high precision GNSS community interests are represented in the future spectrum allocation decisions.

  4. Testing protects against proactive interference in face-name learning.

    PubMed

    Weinstein, Yana; McDermott, Kathleen B; Szpunar, Karl K

    2011-06-01

    Learning face-name pairings at a social function becomes increasingly more difficult the more individuals one meets. This phenomenon is attributable to proactive interference--the negative influence of prior learning on subsequent learning. Recent evidence suggests that taking a memory test can alleviate proactive interference in verbal list learning paradigms. We apply this technique to face-name pair learning. Participants studied four lists of 12 face-name pairings and either attempted to name the 12 faces just studied after every list or did not. Recall attempts after every list improved learning of the fourth list by over 100%. Moreover, no reduction in learning of face-name pairings occurred from list 1 to list 4 for participants who attempted to name studied faces between lists. These results suggest that testing oneself on the names of a group of new acquaintances before moving on to the next group is an effective mnemonic technique for social functions.

  5. Aerofoil testing in a self-streamlining flexible walled wind tunnel. Ph.D. Thesis - Jul. 1987

    NASA Technical Reports Server (NTRS)

    Lewis, Mark Charles

    1988-01-01

    Two-dimensional self-streamlining flexible walled test sections eliminate, as far as experimentally possible, the top and bottom wall interference effects in transonic airfoil testing. The test section sidewalls are rigid, while the impervious top and bottom walls are flexible and contoured to streamline shapes by a system of jacks, without reference to the airfoil model. The concept of wall contouring to eliminate or minimize test section boundary interference in 2-D testing was first demonstrated by NPL in England during the early 40's. The transonic streamlining strategy proposed, developed and used by NPL has been compared with several modern strategies. The NPL strategy has proved to be surprisingly good at providing a wall interference-free test environment, giving model performance indistinguishable from that obtained using the modern strategies over a wide range of test conditions. In all previous investigations the achievement of wall streamlining in flexible walled test sections has been limited to test sections up to those resulting in the model's shock just extending to a streamlined wall. This work however, has also successfully demonstrated the feasibility of 2-D wall streamlining at test conditions where both model shocks have reached and penetrated through their respective flexible walls. Appropriate streamlining procedures have been established and are uncomplicated, enabling flexible walled test sections to cope easily with these high transonic flows.

  6. Failure to Recover from Proactive Semantic Interference and Abnormal Limbic Connectivity in Asymptomatic, Middle-Aged Offspring of Patients with Late-Onset Alzheimer's Disease.

    PubMed

    Sánchez, Stella M; Abulafia, Carolina; Duarte-Abritta, Barbara; de Guevara, M Soledad Ladrón; Castro, Mariana N; Drucaroff, Lucas; Sevlever, Gustavo; Nemeroff, Charles B; Vigo, Daniel E; Loewenstein, David A; Villarreal, Mirta F; Guinjoan, Salvador M

    2017-01-01

    We have obtained previous evidence of limbic dysfunction in middle-aged, asymptomatic offspring of late-onset Alzheimer's disease (LOAD) patients, and failure to recover from proactive semantic interference has been shown to be a sensitive cognitive test in other groups at risk for LOAD. To assess the effects of specific proactive semantic interference deficits as they relate to functional magnetic resonance imaging (fMRI) neocortical and limbic functional connectivity in middle aged offspring of individuals with LOAD (O-LOAD) and age-equivalent controls. We examined 21 O-LOAD and 20 controls without family history of neurodegenerative disorders (CS) on traditional measures of cognitive functioning and the LASSI-L, a novel semantic interference test uniquely sensitive to the failure to recover from proactive interference (frPSI). Cognitive tests then were correlated to fMRI connectivity of seeds located in entorhinal cortex and anterodorsal thalamic nuclei among O-LOAD and CS participants. Relative to CS, O-LOAD participants evidenced lower connectivity between entorhinal cortex and orbitofrontal, anterior cingulate, and anterior temporal cortex. In the offspring of LOAD patients, LASSI-L measures of frPSI were inversely associated with connectivity between anterodorsal thalamus and contralateral posterior cingulate. Intrusions on the task related to frPSI were inversely correlated with a widespread connectivity network involving hippocampal, insular, posterior cingulate, and dorsolateral prefrontal cortices, along with precunei and anterior thalamus in this group. Different patterns of connectivity associated with frPSI were observed among controls. The present results suggest that both semantic interference deficits and connectivity abnormalities might reflect limbic circuit dysfunction as a very early clinical signature of LOAD pathology, as previously demonstrated for other limbic phenotypes, such as sleep and circadian alterations.

  7. Interference control in working memory: comparing groups of children with atypical development.

    PubMed

    Palladino, Paola; Ferrari, Marcella

    2013-01-01

    The study aimed to test whether working memory deficits in children at risk of Learning Disabilities (LD) and/or attention deficit/hyperactivity disorder (ADHD) can be attributed to deficits in interference control, thereby implicating prefrontal systems. Two groups of children known for showing poor working memory (i.e., children with poor comprehension and children with ADHD) were compared to a group of children with specific reading decoding problems (i.e., having severe problems in phonological rather than working memory) and to a control group. All children were tested with a verbal working memory task. Interference control of irrelevant items was examined by a lexical decision task presented immediately after the final recall in about half the trials, selected at random. The interference control measure was therefore directly related to working memory performance. Results confirmed deficient working memory performance in poor comprehenders and children at risk of ADHD + LD. More interestingly, this working memory deficit was associated with greater activation of irrelevant information than in the control group. Poor decoders showed more efficient interference control, in contrast to poor comprehenders and ADHD + LD children. These results indicated that interfering items were still highly accessible to working memory in children who fail the working memory task. In turn, these findings strengthen and clarify the role of interference control, one of the most critical prefrontal functions, in working memory.

  8. Sleep and memory consolidation: motor performance and proactive interference effects in sequence learning.

    PubMed

    Borragán, Guillermo; Urbain, Charline; Schmitz, Rémy; Mary, Alison; Peigneux, Philippe

    2015-04-01

    That post-training sleep supports the consolidation of sequential motor skills remains debated. Performance improvement and sensitivity to proactive interference are both putative measures of long-term memory consolidation. We tested sleep-dependent memory consolidation for visuo-motor sequence learning using a proactive interference paradigm. Thirty-three young adults were trained on sequence A on Day 1, then had Regular Sleep (RS) or were Sleep Deprived (SD) on the night after learning. After two recovery nights, they were tested on the same sequence A, then had to learn a novel, potentially competing sequence B. We hypothesized that proactive interference effects on sequence B due to the prior learning of sequence A would be higher in the RS condition, considering that proactive interference is an indirect marker of the robustness of sequence A, which should be better consolidated over post-training sleep. Results highlighted sleep-dependent improvement for sequence A, with faster RTs overnight for RS participants only. Moreover, the beneficial impact of sleep was specific to the consolidation of motor but not sequential skills. Proactive interference effects on learning a new material at Day 4 were similar between RS and SD participants. These results suggest that post-training sleep contributes to optimizing motor but not sequential components of performance in visuo-motor sequence learning. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Mug shot exposure prior to lineup identification: interference, transference, and commitment effects.

    PubMed

    Dysart, J E; Lindsay, R C; Hammond, R; Dupuis, P

    2001-12-01

    The effects of viewing mug shots on subsequent identification performance are as yet unclear. Two experiments used a live staged-crime paradigm to determine if interpolated eyewitness exposure to mug shots caused interference, unconscious transference, or commitment effects influencing subsequent lineup accuracy. Experiment 1 (N = 104) tested interference effects. Similar correct decision rates were obtained for the mug shot and no mug shot groups from both perpetrator-present and absent lineups. Experiment 2 (N = 132) tested for commitment and transference effects. Results showed that the commitment group made significantly more incorrect identifications than either the control or the transference group, which had similar false-identification rates. Commitment effects present a serious threat to identification accuracy from lineups following mug shot searches.

  10. Simulate different environments TDLAS On the analysis of the test signal strength

    NASA Astrophysics Data System (ADS)

    Li, Xin; Zhou, Tao; Jia, Xiaodong

    2014-12-01

    TDLAS system is the use of the wavelength tuning characteristics of the laser diode, for detecting the absorption spectrum of the gas absorption line. Detecting the gas space, temperature, pressure and flow rate and concentration. The use of laboratory techniques TDLAS gas detection, experimental simulation engine combustion water vapor and smoke. using an optical lens system receives the signal acquisition and signal interference test analysis. Analog water vapor and smoke in two different environments in the sample pool interference. In both experiments environmental interference gas absorption in the optical signal acquisition, signal amplitude variation analysis, and records related to the signal data. In order to study site conditions in the engine combustion process for signal acquisition provides an ideal experimental data .

  11. Aerodynamic results of a support system interference effects test conducted at NASA/LaRC UPWT using an 0.015-scale model of the configuration 140A/B SSV orbiter (0A20B)

    NASA Technical Reports Server (NTRS)

    Campbell, J. H., II; Embury, W. R.

    1974-01-01

    An experimental aerodynamic investigation was conducted to determine the interference effects of a wind tunnel support system. The test article was a 0.015 scale model of the space shuttle orbiter. The primary objective of the test was to determine the extent that aerodynamic simulation of the space shuttle orbiter is affected by base mounting the model, without nozzles, on a straight sting. Two support systems were tested. The characteristics of the support systems are described. Data from the tests are presented in the form of graphs and tables.

  12. Application of the correlation constrained multivariate curve resolution alternating least-squares method for analyte quantitation in the presence of unexpected interferences using first-order instrumental data.

    PubMed

    Goicoechea, Héctor C; Olivieri, Alejandro C; Tauler, Romà

    2010-03-01

    Correlation constrained multivariate curve resolution-alternating least-squares is shown to be a feasible method for processing first-order instrumental data and achieve analyte quantitation in the presence of unexpected interferences. Both for simulated and experimental data sets, the proposed method could correctly retrieve the analyte and interference spectral profiles and perform accurate estimations of analyte concentrations in test samples. Since no information concerning the interferences was present in calibration samples, the proposed multivariate calibration approach including the correlation constraint facilitates the achievement of the so-called second-order advantage for the analyte of interest, which is known to be present for more complex higher-order richer instrumental data. The proposed method is tested using a simulated data set and two experimental data systems, one for the determination of ascorbic acid in powder juices using UV-visible absorption spectral data, and another for the determination of tetracycline in serum samples using fluorescence emission spectroscopy.

  13. Interference effect between neutron direct and resonance capture reactions for neutron-rich nuclei

    NASA Astrophysics Data System (ADS)

    Minato, Futoshi; Fukui, Tokuro

    2017-11-01

    Interference effect of neutron capture cross section between the compound and direct processes is investigated. The compound process is calculated by resonance parameters and the direct process by the potential model. The interference effect is tested for neutron-rich 82Ge and 134Sn nuclei relevant to r-process and light nucleus 13C which is neutron poison in the s-process and produces long-lived radioactive nucleus 14C (T1/2 = 5700 y). The interference effects in those nuclei are significant around resonances, and low energy region if s-wave neutron direct capture is possible. Maxwellian averaged cross sections at kT = 30 and 300 keV are also calculated, and the interference effect changes the Maxwellian averaged capture cross section largely depending on resonance position.

  14. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    PubMed

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-07-01

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  15. The Role of Test Context in Latent Inhibition of Conditioned Inhibition: Part of a Search for General Principles of Associative Interference

    PubMed Central

    Miguez, Gonzalo; Soares, Julia S.; Miller, Ralph R.

    2015-01-01

    Two lick-suppression experiments with rats assessed interference with behavior indicative of conditioned inhibition by a latent inhibition treatment as a function of test context. We asked what effect the test context has, given identical latent inhibition treatment in Phase 1 and identical conditioned inhibition training in Phase 2. In Experiment 1, an AAA vs. AAB context-shift design determined that latent inhibition treatment in Phase 1 attenuated behavior indicative of conditioned inhibition training administered in Phase 2 regardless of the test context, which could reflect a failure to either acquire or express conditioned inhibition. In Experiment 2, an ABA vs. ABB design found that test performance in Contexts A and B reflected the treatments that had been administered in those contexts (i.e., conditioned inhibition was observed in Context B but not A), which could reflect either context specificity of latent inhibition or context specificity of conditioned inhibition. In either case, latent inhibition of conditioned inhibition training in at least some situations was seen to reflect an expression deficit rather than an acquisition deficit. These data, in conjunction with prior reports, suggest that latent inhibition is relatively specific to the context in which it was administered, whereas conditioned inhibition is specific to its training context only when it is the second learned relationship concerning the target cue. These experiments are part of a larger effort to delineate control by the test context of two-phase associative interference as a function of the nature of target training and the nature of interference training. PMID:25875792

  16. The role of test context in latent inhibition of conditioned inhibition: Part of a search for general principles of associative interference.

    PubMed

    Miguez, Gonzalo; Soares, Julia S; Miller, Ralph R

    2015-09-01

    In two lick suppression experiments with rats, we assessed interference with behavior indicative of conditioned inhibition by a latent inhibition treatment as a function of test context. We asked what effect the test context has, given identical latent inhibition treatments in Phase 1 and identical conditioned inhibition trainings in Phase 2. In Experiment 1, an AAA versus AAB context-shift design determined that the latent inhibition treatment in Phase 1 attenuated behavior indicative of the conditioned inhibition training administered in Phase 2, regardless of the test context, which could reflect a failure to either acquire or express conditioned inhibition. In Experiment 2, an ABA versus ABB design showed that test performance in Contexts A and B reflected the treatments that had been administered in those contexts (i.e., conditioned inhibition was observed in Context B but not A), which could reflect either the context specificity of either latent inhibition or conditioned inhibition. In either case, latent inhibition of conditioned inhibition training in at least some situations was seen to reflect an expression deficit rather than an acquisition deficit. These data, in conjunction with prior reports, suggest that latent inhibition is relatively specific to the context in which it was administered, whereas conditioned inhibition is specific to its training context only when it is the second-learned relationship concerning the target cue. These experiments are part of a larger effort to delineate control by the test context of two-phase associative interference, as a function of the nature of target training and the nature of interference training.

  17. Performance of a new test strip for freestyle blood glucose monitoring systems.

    PubMed

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations <75 mg/dL, 73%, 100%, and 100% of the individual capillary blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  18. A wall interference assessment/correction system

    NASA Technical Reports Server (NTRS)

    Lo, Ching F.; Ulbrich, N.; Sickles, W. L.; Qian, Cathy X.

    1992-01-01

    A Wall Signature method, the Hackett method, has been selected to be adapted for the 12-ft Wind Tunnel wall interference assessment/correction (WIAC) system in the present phase. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating wall interferences at the model location. The Wall Signature method will be formulated for application to the unique geometry of the 12-ft Tunnel. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method-Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected parameters with those for the free-air simulation. Each set of wind tunnel/test article numerical simulations provides data to validate the WIAC method. A numerical wind tunnel test simulation is initiated to validate the WIAC methods developed in the project. In the present reported period, the blockage correction has been developed and implemented for a rectangular tunnel as well as the 12-ft Pressure Tunnel. An improved wall interference assessment and correction method for three-dimensional wind tunnel testing is presented in the appendix.

  19. User's manual for a 0.3-m TCT wall interference assessment/correction procedure: 8- by 24-inch airfoil test section

    NASA Technical Reports Server (NTRS)

    Gumbert, C. R.

    1985-01-01

    A transonic Wall-Interference Assessment/Correction (WIAC) procedure has been developed and verified for the 8- by 24-inch airfoil test section of the Langley 0.3-m Transonic Cryogenic Tunnel. This report is a user's manual for the correction procedure. It includes a listing of the computer procedure file as well as input for and results from a step-by-step sample case.

  20. Interference and Noise in and Adjacent to the Loran-C Spectrum at Airports

    DOT National Transportation Integrated Search

    1980-05-01

    Electrical noise and interference in the LORAN-C frequency band was measured at two rural airports in Vermont and a major airport in Boston, Mass. The purpose of the test program was to determine the potential interfering sources that could affect th...

  1. Influence of press-fit parameters on the primary stability of uncemented femoral resurfacing implants.

    PubMed

    Gebert, A; Peters, J; Bishop, N E; Westphal, F; Morlock, M M

    2009-01-01

    Primary stability is essential to the success of uncemented prostheses. It is strongly influenced by implantation technique, implant design and bone quality. The goal of this study was to investigate the effect of press-fit parameters on the primary stability of uncemented femoral head resurfacing prostheses. An in vitro study with human specimens and prototype implants (nominal radial interference 170 and 420 microm) was used to investigate the effect of interference on primary stability. A finite element model was used to assess the influence of interference, friction between implant and bone, and bone quality. Primary stability was represented by the torque capacity of the implant. The model predicted increasing stability with actual interference, bone quality and friction coefficient; plastic deformation of the bone began at interferences of less than 100 microm. Experimentally, however, stability was not related to interference. This may be due to abrasion or the collapse of trabecular bone structures at higher interferences, which could not be captured by the model. High nominal interferences as tested experimentally appear unlikely to result in improved stability clinically. An implantation force of about 2,500 N was estimated to be sufficient to achieve a torque capacity of about 30 N m with a small interference (70 microm).

  2. Axial-Force Reduction by Interference Between Jet and Neighboring Afterbody

    NASA Technical Reports Server (NTRS)

    Pitts, William C.; Wiggins, Lyle E.

    1960-01-01

    Experimental results are presented for an exploratory investigation of the effectiveness of interference between jet and afterbody in reducing the axial force on an afterbody with a neighboring jet. In addition to the interference axial force., measurements are presented of the interference normal force and the center of pressure of the interference normal force. The free-stream Mach number was 2.94, the jet-exit Mach number was 2.71, and the Reynolds number was 0.25 x 10, based on body diameter. The variables investigated include static-pressure ratio of the jet (up to 9), nacelle position relative to afterbody, angle of attack (-5 deg to 10 deg), and afterbody shape. Two families of afterbody shapes were tested. One family consisted of tangent-ogive bodies of revolution with varying length and base areas. The other family was formed by taking a planar slice off a circular cylinder with varying angle between the plane and cylinder. The trends with these variables are shown for conditions near maximum jet-afterbody interference. The interference axial forces are large and favorable. For several configurations the total afterbody axial force is reduced to zero by the interference.

  3. Effects of auditory radio interference on a fine, continuous, open motor skill.

    PubMed

    Lazar, J M; Koceja, D M; Morris, H H

    1995-06-01

    The effects of human speech on a fine, continuous, and open motor skill were examined. A tape of auditory human radio traffic was injected into a tank gunnery simulator during each training session for 4 wk. of training for 3 hr. a week. The dependent variables were identification time, fire time, kill time, systems errors, and acquisition errors. These were measured by the Unit Conduct Of Fire Trainer (UCOFT). The interference was interjected into the UCOFT Tank Table VIII gunnery test. A Solomon four-group design was used. A 2 x 2 analysis of variance was used to assess whether interference gunnery training resulted in improvements in interference posttest scores. During the first three weeks of training, the interference group committed 106% more systems errors and 75% more acquisition errors than the standard group. The interference training condition was associated with a significant improvement from pre- to posttest of 44% in over-all UCOFT scores; however, when examined on the posttest the standard training did not improve performance significantly over the same period. It was concluded that auditory radio interference degrades performance of this fine, continuous, open motor skill, and interference training appears to abate the effects of this degradation.

  4. Heterophilic antibody interference affecting multiple hormone assays: Is it due to rheumatoid factor?

    PubMed

    Mongolu, Shiva; Armston, Annie E; Mozley, Erin; Nasruddin, Azraai

    2016-01-01

    Assay interference with heterophilic antibodies has been well described in literature. Rheumatoid factor is known to cause similar interference leading to falsely elevated hormone levels when measured by immunometric methods like enzyme-linked immunosorbent assay (ELISA) or multiplex immunoasays (MIA). We report a case of a 60-year-old male patient with a history of rheumatoid arthritis referred to our endocrine clinic for investigation of hypogonadism and was found to have high serum levels of LH, FSH, SHBG, Prolactin, HCG and TSH. We suspected assay interference and further tests were performed. We used Heteroblock tubes and PEG precipitation to eliminate the interference and the hormone levels post treatment were in the normal range. We believe the interference was caused by high serum levels of rheumatoid factor. Although he was treated with thyroxine for 3 years, we believe he may have been treated inappropriately as his Free T4 level was always normal despite high TSH due to assay interference. Our case illustrates the phenomenon of heterophilic antibody interference likely due to high levels of rheumatoid factor. It is essential for clinicians and endocrinologists in particular to be aware of this possibility when making treatment decisions in these groups of patients.

  5. Facilitation and interference in naming: A consequence of the same learning process?

    PubMed

    Hughes, Julie W; Schnur, Tatiana T

    2017-08-01

    Our success with naming depends on what we have named previously, a phenomenon thought to reflect learning processes. Repeatedly producing the same name facilitates language production (i.e., repetition priming), whereas producing semantically related names hinders subsequent performance (i.e., semantic interference). Semantic interference is found whether naming categorically related items once (continuous naming) or multiple times (blocked cyclic naming). A computational model suggests that the same learning mechanism responsible for facilitation in repetition creates semantic interference in categorical naming (Oppenheim, Dell, & Schwartz, 2010). Accordingly, we tested the predictions that variability in semantic interference is correlated across categorical naming tasks and is caused by learning, as measured by two repetition priming tasks (picture-picture repetition priming, Exp. 1; definition-picture repetition priming, Exp. 2, e.g., Wheeldon & Monsell, 1992). In Experiment 1 (77 subjects) semantic interference and repetition priming effects were robust, but the results revealed no relationship between semantic interference effects across contexts. Critically, learning (picture-picture repetition priming) did not predict semantic interference effects in either task. We replicated these results in Experiment 2 (81 subjects), finding no relationship between semantic interference effects across tasks or between semantic interference effects and learning (definition-picture repetition priming). We conclude that the changes underlying facilitatory and interfering effects inherent to lexical access are the result of distinct learning processes where multiple mechanisms contribute to semantic interference in naming. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Wing-Fuselage Interference, Tail Buffeting, and Air Flow About the Tail of a Low-Wing Monoplane

    NASA Technical Reports Server (NTRS)

    White, James A; Hood, Manley J

    1935-01-01

    This report presents the results of wind tunnel tests on a Mcdonnell Douglas airplane to determine the wing-fuselage interference of a low-wing monoplane. The tests included a study of tail buffeting and the air flow in the region of the tail. The airplane was tested with and without the propeller slipstream, both in the original condition and with several devices designed to reduce or eliminate tail buffeting. The devices used were wing-fuselage fillets, a NACA cowling, reflexed trailing edge of the wing, and stub auxiliary airfoils.

  7. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Cunningham and J. Shank

    2004-11-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I&C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner.

  8. The Cost of Being Watched: Stroop Interference Increases under Concomitant Eye Contact

    ERIC Educational Resources Information Center

    Conty, Laurence; Gimmig, David; Belletier, Clement; George, Nathalie; Huguet, Pascal

    2010-01-01

    Current models in social neuroscience advance that eye contact may automatically recruit cognitive resources. Here, we directly tested this hypothesis by evaluating the distracting strength of eye contact on concurrent visual processing in the well-known Stroop's paradigm. As expected, participants showed stronger Stroop interference under…

  9. Working Memory Capacity and Stroop Interference: Global versus Local Indices of Executive Control

    ERIC Educational Resources Information Center

    Meier, Matt E.; Kane, Michael J.

    2013-01-01

    Two experiments examined the relations among working memory capacity (WMC), congruency-sequence effects, proportion-congruency effects, and the color-word Stroop effect to test whether congruency-sequence effects might inform theoretical claims regarding WMC's prediction of Stroop interference. In Experiment 1, subjects completed either a…

  10. Support interference of wind tunnel models: A selective annotated bibliography

    NASA Technical Reports Server (NTRS)

    Tuttle, M. H.; Gloss, B. B.

    1981-01-01

    This bibliography, with abstracts, consists of 143 citations arranged in chronological order by dates of publication. Selection of the citations was made for their relevance to the problems involved in understanding or avoiding support interference in wind tunnel testing throughout the Mach number range. An author index is included.

  11. Support interference of wind tunnel models: A selective annotated bibliography

    NASA Technical Reports Server (NTRS)

    Tuttle, M. H.; Lawing, P. L.

    1984-01-01

    This bibliography, with abstracts, consists of 143 citations arranged in chronological order by dates of publication. Selection of the citations was made for their relevance to the problems involved in understanding or avoiding support interference in wind tunnel testing throughout the Mach number range. An author index is included.

  12. Storage and Retrieval Changes that Occur in the Development and Release of PI

    ERIC Educational Resources Information Center

    Chechile, Richard; Butler, Keith

    1975-01-01

    A Bayesian statistical procedure separating storage from retrieval was used to study development and release of proactive interference in the Brown-Peterson paradigm. A theory of PI is developed stressing response competition at test time and interference in transfer between short- and long-term memory. (CHK)

  13. Dual Coding in Children.

    ERIC Educational Resources Information Center

    Burton, John K.; Wildman, Terry M.

    The purpose of this study was to test the applicability of the dual coding hypothesis to children's recall performance. The hypothesis predicts that visual interference will have a small effect on the recall of visually presented words or pictures, but that acoustic interference will cause a decline in recall of visually presented words and…

  14. The Ranschburg Effect: Tests of the Guessing-Bias and Proactive Interference Hypotheses

    ERIC Educational Resources Information Center

    Walsh, Michael F.; Schwartz, Marian

    1977-01-01

    The guessing-bias and proactive interference hypotheses of the Ranschburg Effect were investigated by giving three groups different instructions as to guessing during recall. Results failed to support the prediction that the effect should be reduced or eliminated on shift trials. Neither hypothesis received significant support. (CHK)

  15. Black English Phonology: The Question of Reading Interference.

    ERIC Educational Resources Information Center

    Melmed, Paul Jay

    An investigation was conducted to test the assumption that Black English (BE) dialect interferes with reading. Data from 45 lower standard English (SE) speakers were collected and analyzed to measure racial group differences on auditory discrimination, oral reading, BE phonology usage, and silent reading comprehension. Dialect differences analyzed…

  16. 49 CFR 236.76 - Tagging of wires and interference of wires or tags with signal apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... with signal apparatus. 236.76 Section 236.76 Transportation Other Regulations Relating to... wires and interference of wires or tags with signal apparatus. Each wire shall be tagged or otherwise so... apparatus. [49 FR 3384, Jan. 26, 1984] Inspections and Tests; All Systems ...

  17. 49 CFR 236.76 - Tagging of wires and interference of wires or tags with signal apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... with signal apparatus. 236.76 Section 236.76 Transportation Other Regulations Relating to... wires and interference of wires or tags with signal apparatus. Each wire shall be tagged or otherwise so... apparatus. [49 FR 3384, Jan. 26, 1984] Inspections and Tests; All Systems ...

  18. Load Theory of Selective Attention and Cognitive Control

    ERIC Educational Resources Information Center

    Lavie, Nilli; Hirst, Aleksandra; de Fockert, Jan W.; Viding, Essi

    2004-01-01

    A load theory of attention in which distractor rejection depends on the level and type of load involved in current processing was tested. A series of experiments demonstrates that whereas high perceptual load reduces distractor interference, working memory load or dual-task coordination load increases distractor interference. These findings…

  19. Interference Confocal Microscope Integrated with Spatial Phase Shifter.

    PubMed

    Wang, Weibo; Gu, Kang; You, Xiaoyu; Tan, Jiubin; Liu, Jian

    2016-08-24

    We present an interference confocal microscope (ICM) with a new single-body four-step simultaneous phase-shifter device designed to obtain high immunity to vibration. The proposed ICM combines the respective advantages of simultaneous phase shifting interferometry and bipolar differential confocal microscopy to obtain high axis resolution, large dynamic range, and reduce the sensitivity to vibration and reflectance disturbance seamlessly. A compact single body spatial phase shifter is added to capture four phase-shifted interference signals simultaneously without time delay and construct a stable and space-saving simplified interference confocal microscope system. The test result can be obtained by combining the interference phase response and the bipolar property of differential confocal microscopy without phase unwrapping. Experiments prove that the proposed microscope is capable of providing stable measurements with 1 nm of axial depth resolution for either low- or high-numerical aperture objective lenses.

  20. Effect of vaccination on parvovirus antigen testing in kittens.

    PubMed

    Patterson, Erin V; Reese, Michael J; Tucker, Sylvia J; Dubovi, Edward J; Crawford, P Cynda; Levy, Julie K

    2007-02-01

    To determine the frequency and duration of feline panleukopenia virus (FPV) vaccine-induced interference with fecal parvovirus diagnostic testing in cats. Prospective controlled study. Sixty-four 8- to 10-week-old specific-pathogen-free kittens. Kittens were inoculated once with 1 of 8 commercial multivalent vaccines containing modified-live virus (MLV) or inactivated FPV by the SC or intranasal routes. Feces were tested for parvovirus antigen immediately prior to vaccination, then daily for 14 days with 3 tests designed for detection of canine parvovirus. Serum anti-FPV antibody titers were determined by use of hemagglutination inhibition prior to vaccination and 14 days later. All fecal parvovirus test results were negative prior to vaccination. After vaccination, 1 kitten had positive test results with test 1, 4 kittens had positive results with test 2, and 13 kittens had positive results with test 3. Only 1 kitten had positive results with all 3 tests, and only 2 of those tests were subjectively considered to have strongly positive results. At 14 days after vaccination, 31% of kittens receiving inactivated vaccines had protective FPV titers, whereas 85% of kittens receiving MLV vaccines had protective titers. Animal shelter veterinarians should select fecal tests for parvovirus detection that have high sensitivity for FPV and low frequency of vaccine-related test interference. Positive parvovirus test results should be interpreted in light of clinical signs, vaccination history, and results of confirmatory testing. Despite the possibility of test interference, the benefit provided by universal MLV FPV vaccination of cats in high-risk environments such as shelters outweighs the impact on diagnostic test accuracy.

  1. Slotted-wall research with disk and parachute models in a low-speed wind tunnel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macha, J.M.; Buffington, R.J.; Henfling, J.L.

    1990-01-01

    An experimental investigation of slotted-wall blockage interference has been conducted using disk and parachute models in a low speed wind tunnel. Test section open area ratio, model geometric blockage ratio, and model location along the length of the test section were systematically varied. Resulting drag coefficients were compared to each other and to interference-free measurements obtained in a much larger wind tunnel where the geometric blockage ratio was less than 0.0025. 9 refs., 10 figs.

  2. Long working distance interference microscope

    DOEpatents

    Sinclair, Michael B.; DeBoer, Maarten P.; Smith, Norman F.

    2004-04-13

    Disclosed is a long working distance interference microscope suitable for three-dimensional imaging and metrology of MEMS devices and test structures on a standard microelectronics probe station. The long working distance of 10-30 mm allows standard probes or probe cards to be used. This enables nanometer-scale 3-D height profiles of MEMS test structures to be acquired across an entire wafer. A well-matched pair of reference/sample objectives is not required, significantly reducing the cost of this microscope, as compared to a Linnik microinterferometer.

  3. Mapping interference resolution across task domains: A shared control process in left inferior frontal gyrus

    PubMed Central

    Nelson, James K.; Reuter-Lorenz, Patricia A.; Persson, Jonas; Sylvester, Ching-Yune C.; Jonides, John

    2009-01-01

    Work in functional neuroimaging has mapped interference resolution processing onto left inferior frontal regions for both verbal working memory and a variety of semantic processing tasks. The proximity of the identified regions from these different tasks suggests the existence of a common, domain-general interference resolution mechanism. The current research specifically tests this idea in a within-subject design using fMRI to assess the activation associated with variable selection requirements in a semantic retrieval task (verb generation) and a verbal working memory task with a trial-specific proactive interference manipulation (recent-probes). High interference trials on both tasks were associated with activity in the midventrolateral region of the left inferior frontal gyrus, and the regions activated in each task strongly overlapped. The results indicate that an elemental component of executive control associated with interference resolution during retrieval from working memory and from semantic memory can be mapped to a common portion of the left inferior frontal gyrus. PMID:19111526

  4. Potential of phytoceuticals to affect antibiotic residue detection tests in cow milk in a randomised trial

    PubMed Central

    Mullen, Keena AE; Beasley, Erin; Rizzo, Julio Q; Washburn, Steven P; Baynes, Ronald E; Mason, Sharon E

    2017-01-01

    Mastitis is a costly disease for dairy farmers. Some dairy farmers use herbal products, or phytoceuticals, to treat mastitis. Phytoceuticals have not been approved for this use by the United States Food and Drug Administration, and have not been tested to determine how they impact antibiotic residue detection testing. The current study tested the potential for phytoceuticals to cause positive results on two milk antibiotic residue screening tests, the Delvotest P and Charm SL Beta-lactam test, or to interfere with the detection of antibiotics by these tests. The three phytoceuticals tested were labelled for intramammary, topical or intravulvar administration. Testing was performed in vitro using the products diluted in milk obtained from healthy organic dairy cows. Phytoceuticals were tested at concentrations ranging from 1.5 per cent to 100 per cent. Concentration levels were replicated at least twice on each milk antibiotic residue screening test. The Delvotest P is based on detection of bacterial inhibitors and no positive results were obtained for any product at concentrations less than 50 per cent. The Charm SL Beta-lactam test uses a receptor for the detection of beta-lactam antibiotics and no concentration of phytoceuticals caused an interference with these tests. Based on dilution of the products in bovine milk at physiologically achievable levels, phytoceutical products tested at levels expected after treatment do not cause positive test results for the Delvotest P nor do they interfere with the Charm SL Beta-lactam test in detection of various antibiotics. PMID:28890791

  5. Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.

    PubMed

    Patel, Khushbu K; Gronowski, Ann M

    2016-06-01

    This case report investigates the origin of a false positive result on a serum qualitative human chorionic gonadotropin (hCG) device. A 46-year-old woman diagnosed with chronic myeloid leukemia presented with nausea and vomiting. A qualitative serum hCG test was interpreted as positive; however, a quantitative serum hCG test was negative (<5IU/L). To further investigate this discrepancy, the sample was pretreated with heterophilic blocking reagent (HBR). Additionally, the sample was tested on other qualitative hCG devices composed of antibodies from different animal sources. Blocking reagent from an automated quantitative immunoassay was also tested for its ability to inhibit the heterophile antibody interference. The qualitative test result was negative after pretreatment with heterophilic blocking reagent. Other devices composed of antibodies from different animal sources also demonstrated mixed results with the patient's sample. Blocking reagent obtained from the automated quantitative assay inhibited the heterophile antibody interference in the patient's sample. This case demonstrates that positive serum point-of-care hCG results should be interpreted with caution and confirmed with a quantitative serum hCG immunoassay when clinical suspicion is raised. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Marshall Space Flight Center Electromagnetic Compatibility Design and Interference Control (MEDIC) handbook

    NASA Astrophysics Data System (ADS)

    Clark, T. L.; McCollum, M. B.; Trout, D. H.; Javor, K.

    1995-06-01

    The purpose of the MEDIC Handbook is to provide practical and helpful information in the design of electrical equipment for electromagnetic compatibility (EMS). Included is the definition of electromagnetic interference (EMI) terms and units as well as an explanation of the basic EMI interactions. An overview of typical NASA EMI test requirements and associated test setups is given. General design techniques to minimize the risk of EMI and EMI suppression techniques at the board and equipment interface levels are presented. The Handbook contains specific EMI test compliance design techniques and retrofit fixes for noncompliant equipment. Also presented are special tests that are useful in the design process or in instances of specification noncompliance.

  7. Marshall Space Flight Center Electromagnetic Compatibility Design and Interference Control (MEDIC) handbook

    NASA Technical Reports Server (NTRS)

    Clark, T. L.; Mccollum, M. B.; Trout, D. H.; Javor, K.

    1995-01-01

    The purpose of the MEDIC Handbook is to provide practical and helpful information in the design of electrical equipment for electromagnetic compatibility (EMS). Included is the definition of electromagnetic interference (EMI) terms and units as well as an explanation of the basic EMI interactions. An overview of typical NASA EMI test requirements and associated test setups is given. General design techniques to minimize the risk of EMI and EMI suppression techniques at the board and equipment interface levels are presented. The Handbook contains specific EMI test compliance design techniques and retrofit fixes for noncompliant equipment. Also presented are special tests that are useful in the design process or in instances of specification noncompliance.

  8. Transfer and interference of motor skills in people with intellectual disability.

    PubMed

    Mohan, A; Singh, A P; Mandal, M K

    2001-08-01

    Atypical laterality (i.e. the lack of a clear pattern of lateralization) has been found to be a characteristic feature of individuals with intellectual disability (ID). The evidence for this has been based on 'handedness' studies which have contained little information about the ability of people with ID to carry out interhemispheric tasks reflecting bilateral transfer or interference. The present study examined this capacity in individuals with ID by utilizing bilateral transfer and interference paradigms. Right-handed subjects with ID (IQ = 55-76) and controls matched for age and sex were tested for bilateral transfer of motor skill in contralateral hands with a mirror-drawing task. The subjects were also tested for their ability to perform a finger-tapping task while processing verbal and non-verbal stimuli. The findings indicated that people with ID are significantly deficient relative to matched controls in bilateral transfer of motor skills from their non-preferred (left) hand to their preferred (right) one. The effect of interference during performance of the dual task was significantly greater in individuals with ID. Subjects with ID were found to perform better with their non-preferred than with their preferred hand. A within-group comparison revealed that right-handed performance was more affected by interference than left in these subjects.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Dr. Yanhua; McCandless, Andrew Bascom

    The main objective of this project is to improve the performance and reliability of sensor networks in the smart grid through an active interference cancellation technique that can effectively eliminate broadband electromagnetic interference (EMI) and radio frequency interference (RFI). This noise cancellation provides real-time monitoring the RF environment and automatically optimization of the signal fidelity. To determine the feasibility of the proposed technique and quantify the level of improvement in key system parameters, such as data rate, signal bandwidth, and cost saving, the tasks carried out during Phase I were 1) defining the problem statement, 2) developing a design thatmore » will solve the sensors’ reliably problem, 3) carrying out initial testing with a prototype, and 4) developing an integrated photonic chip version that could be built in a follow-on Phase II effort. The technology demonstration was successfully proven the feasibility of a mission assured photonic sensor system (MAPSS) that will address a major interference problem in smart grid deployments. The significant results demonstrated from bench-top testing show that the technology is capable of maintaining the error free communication link in the presence of various type of interference. The technology’s wideband performance in GHz is also verified and would be suitable for sensors deploying throughout the smart grid system.« less

  10. In vitro interference by acetaminophen, aspirin, and metamizole in serum measurements of glucose, urea, and creatinine.

    PubMed

    Luna-Záizar, Hilda; Virgen-Montelongo, María; Cortez-Álvarez, Cesar R; Ruiz-Quezada, Sandra L; Escutia-Gutiérrez, Raymundo; García-Lemus, Cuauhtémoc R; Mendizabal-Ruiz, Adriana P

    2015-05-01

    Here we aimed to investigate the in vitro effects of three analgesic-antipyretic drugs frequently used in clinical practice in Mexico - acetaminophen (AAP), aspirin (ASA) and metamizole (MMZ) - on serum measurements of glucose, urea, and creatinine. Each analyte was measured in a base-serum pool spiked with the drugs at subtherapeutic, therapeutic, and toxic doses. Serum glucose and urea were measured using the hexokinase/G-6PDH and urease/GLDH kinetic assays, respectively. Serum creatinine (SCr) was measured with a Jaffe procedure based on the alkaline-picrate reaction and with an enzymatic dry-chemistry system. Measurements were carried out in IL-Monarch and Vitros DT60-II analyzers, respectively. Data were analyzed by the difference-paired interference test and by ANOVA. By the kinetic Jaffe/Monarch procedure, we found positive interference by the drugs on the SCr measurements and by only ASA for urea measurement. For creatinine measurements, the total errors (TEs) were 22-51%, 18-105%, and 15-26% for AAP, ASA, and MMZ respectively, while for urea measurement the TE was 16-21% for ASA. A negative interference by MMZ on SCr (TE=-47%), but no-interference for AAP or ASA, were found via the enzymatic/DT60-II system. In vitro positive interference induced by AAP, ASA, and MMZ (via the alkaline-picrate reaction), or negative interference by MMZ (via a dry-chemistry system), on the SCr measurements highlights the importance of investigating all possible sources of variation that may alter the accuracy of the laboratory tests, in order to provide useful results for making medical decisions for optimal patient care. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. The effects of a single bout of exercise on motor memory interference in the trained and untrained hemisphere.

    PubMed

    Lauber, Benedikt; Franke, Steffen; Taube, Wolfgang; Gollhofer, Albert

    2017-04-07

    Increasing evidence suggests that cardiovascular exercise has positive effects on motor memory consolidation. In this study, we investigated whether a single session of high-intensity interval training (HIIT) mitigates the effects of practicing an interfering motor task. Furthermore, learning and interference effects were assessed in the actively trained and untrained limb as it is known that unilateral motor learning can cause bilateral adaptations. Subjects performed a ballistic training and then the HIIT either before (HIIT_before) or after (HIIT_after) practicing an interfering accuracy task (AT). The control group (No_HIIT) did not participate in the HIIT but rested instead. Performance in the ballistic task (BT) was tested before and after the ballistic training, after the exercise and practice of the AT and 24h later. After ballistic training, all groups showed comparable increases in performance in the trained and untrained limb. Despite the practice of the AT, HIIT_before maintained their BT performance after the high-intensity interval training whereas HIIT_after (trend) & No_HIIT showed prominent interference effects. After 24h, HIIT_before still did not show any interference effects but further improved ballistic motor performance. HIIT_after counteracted the interference resulting in a comparable BT performance after 24h than directly after the ballistic training while No_HIIT had a significantly lower BT performance in the retention test. The results were similar in the trained and untrained limb. The current results imply that a single session of cardiovascular exercise can prevent motor interference in the trained and untrained hemisphere. Overall learning was best, and interference least, when HIIT was performed before the interfering motor task. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  12. An interference model of visual working memory.

    PubMed

    Oberauer, Klaus; Lin, Hsuan-Yu

    2017-01-01

    The article introduces an interference model of working memory for information in a continuous similarity space, such as the features of visual objects. The model incorporates the following assumptions: (a) Probability of retrieval is determined by the relative activation of each retrieval candidate at the time of retrieval; (b) activation comes from 3 sources in memory: cue-based retrieval using context cues, context-independent memory for relevant contents, and noise; (c) 1 memory object and its context can be held in the focus of attention, where it is represented with higher precision, and partly shielded against interference. The model was fit to data from 4 continuous-reproduction experiments testing working memory for colors or orientations. The experiments involved variations of set size, kind of context cues, precueing, and retro-cueing of the to-be-tested item. The interference model fit the data better than 2 competing models, the Slot-Averaging model and the Variable-Precision resource model. The interference model also fared well in comparison to several new models incorporating alternative theoretical assumptions. The experiments confirm 3 novel predictions of the interference model: (a) Nontargets intrude in recall to the extent that they are close to the target in context space; (b) similarity between target and nontarget features improves recall, and (c) precueing-but not retro-cueing-the target substantially reduces the set-size effect. The success of the interference model shows that working memory for continuous visual information works according to the same principles as working memory for more discrete (e.g., verbal) contents. Data and model codes are available at https://osf.io/wgqd5/. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. Suspected Testosterone-Producing Tumor in a Patient Taking Biotin Supplements

    PubMed Central

    Stieglitz, Heather M; Korpi-Steiner, Nichole; Katzman, Brooke; Mersereau, Jennifer E; Styner, Maya

    2018-01-01

    Abstract A perimenopausal woman presented with palpitations, hirsutism, and inability to lose weight. Laboratory tests revealed an unusual endocrine hormonal profile including pituitary hormones (TSH, ACTH, and prolactin) below reference intervals and gonadal (testosterone) and adrenal (cortisol) hormones above reference intervals. Ultimately, after a comprehensive workup including a scheduled surgical procedure, abnormal laboratories were determined due to biotin interference. Biotin (vitamin B7) is a water-soluble vitamin and essential cofactor for the metabolism of fatty acids, glucose, and amino acids. The recommended daily intake of biotin for adults is 30 µg/d. Many over-the-counter products, particularly those marketed for hair, skin, and nail growth, contain biotin 100-fold of recommended daily intake. This case is unique due to the abnormalities observed not only in the well-described TSH “sandwich” immunoassay, but also in tests for gonadal steroids, adrenal, and pituitary hormones. Falsely high as well as falsely low results can be ascribed to biotin. Competitive immunoassays (Fig. 1A)— in this case, tests used initially for serum cortisol and testosterone— can demonstrate falsely high results. Interference falsely lowers the immunometric “sandwich” immunoassay (Fig. 1B)—in this case, TSH. Biotin effect on our patient’s endocrine testing led to decidedly abnormal findings, unnecessary medical referrals and diagnostic studies, and comprehensible psychological distress. Interference with one immunoassay, TSH, persisted a full 2 weeks after discontinuation of biotin; indeed, some tests demonstrate sensitivity to lesser quantities of biotin. Improved communication between patients, health care providers, and laboratory professionals is required concerning the likelihood of biotin interference with immunoassays.

  14. CO2 blood test

    MedlinePlus

    Bicarbonate test; HCO3-; Carbon dioxide test; TCO2; Total CO2; CO2 test - serum; Acidosis - CO2; Alkalosis - CO2 ... Many medicines can interfere with blood test results. Your health ... need to stop taking any medicines before you have this test. DO ...

  15. Evaluation of electrostatic charge effects on the data processing system and the orbiter communication and tracking receivers

    NASA Technical Reports Server (NTRS)

    Lawton, R. M.

    1975-01-01

    An analysis of radiated interference test results obtained from frictionally charged Orbiter TPS tile was presented. The tests included the measurement of noise pick-up by Orbiter S-band, L-band, C-band, and Ku-band antennas located beneath the tiles in a manner simulating their installation on Orbiter. In addition, the radiated field characteristics resulting from the static discharge was determined. The results are analyzed as to their effect on data bus equipment and on Orbiter Communications and Tracking (C&T) receivers. It was concluded that the radiated interference should have no effect on MDM's. However the CPU, IOP and PMU enclosures require some minor modification to assure immunity from P-static interference. Orbiter antenna tests indicate that the S-band receiver should not be affected by P-static noise. The TACAN and Radar Altimeter performance appears to be adequate but with a small margin. MSBLS performance is uncertain because laboratory instrumentation cannot approach the MSBLS sensitivity.

  16. Neurophysiological correlates of post-hypnotic alexia: a controlled study with Stroop test.

    PubMed

    Casiglia, Edoardo; Schiff, Sami; Facco, Enrico; Gabbana, Amos; Tikhonoff, Valérie; Schiavon, Laura; Bascelli, Anna; Avdia, Marsel; Tosello, Maria Teresa; Rossi, Augusto Mario; Haxhi Nasto, Hilda; Guidotti, Federica; Giacomello, Margherita; Amodio, Piero

    2010-01-01

    To clarify whether hypnotically-induced alexia was able to reduce the Stroop effect due to color/word interference, 12 volunteers (6 with high and 6 with low hypnotizability according to Stanford Hypnotic Susceptibility Scale Form C) underwent a Stroop test consisting of measuring, both in basal conditions and during post-hypnotic alexia, the reaction times (RT) at appearance of a colored word indicating a color. In basal conditions, RT were greater in case of incongruence. In highly hypnotizable participants, the interference was less pronounced during post-hypnotic alexia (-34%, p = 0.03). During alexia, late positive complexamplitude was also greater for congruent than incongruent conditions (p < 0.03), and cardiovascular response to stress was less pronounced as well. In participants showing low hypnotizability, no reduction of Stroop effect was detected during post-hypnotic alexia. Posthypnotic alexia is therefore a real and measurable phenomenon, capable of reducing the color-word interference and the haemodynamic effects of the Stroop test.

  17. How does susceptibility to proactive interference relate to speech recognition in aided and unaided conditions?

    PubMed

    Ellis, Rachel J; Rönnberg, Jerker

    2015-01-01

    Proactive interference (PI) is the capacity to resist interference to the acquisition of new memories from information stored in the long-term memory. Previous research has shown that PI correlates significantly with the speech-in-noise recognition scores of younger adults with normal hearing. In this study, we report the results of an experiment designed to investigate the extent to which tests of visual PI relate to the speech-in-noise recognition scores of older adults with hearing loss, in aided and unaided conditions. The results suggest that measures of PI correlate significantly with speech-in-noise recognition only in the unaided condition. Furthermore the relation between PI and speech-in-noise recognition differs to that observed in younger listeners without hearing loss. The findings suggest that the relation between PI tests and the speech-in-noise recognition scores of older adults with hearing loss relates to capability of the test to index cognitive flexibility.

  18. How does susceptibility to proactive interference relate to speech recognition in aided and unaided conditions?

    PubMed Central

    Ellis, Rachel J.; Rönnberg, Jerker

    2015-01-01

    Proactive interference (PI) is the capacity to resist interference to the acquisition of new memories from information stored in the long-term memory. Previous research has shown that PI correlates significantly with the speech-in-noise recognition scores of younger adults with normal hearing. In this study, we report the results of an experiment designed to investigate the extent to which tests of visual PI relate to the speech-in-noise recognition scores of older adults with hearing loss, in aided and unaided conditions. The results suggest that measures of PI correlate significantly with speech-in-noise recognition only in the unaided condition. Furthermore the relation between PI and speech-in-noise recognition differs to that observed in younger listeners without hearing loss. The findings suggest that the relation between PI tests and the speech-in-noise recognition scores of older adults with hearing loss relates to capability of the test to index cognitive flexibility. PMID:26283981

  19. Why does lag affect the durability of memory-based automaticity: loss of memory strength or interference?

    PubMed

    Wilkins, Nicolas J; Rawson, Katherine A

    2013-10-01

    In Rickard, Lau, and Pashler's (2008) investigation of the lag effect on memory-based automaticity, response times were faster and proportion of trials retrieved was higher at the end of practice for short lag items than for long lag items. However, during testing after a delay, response times were slower and proportion of trials retrieved was lower for short lag items than for long lag items. The current study investigated the extent to which the lag effect on the durability of memory-based automaticity is due to interference or to the loss of memory strength with time. Participants repeatedly practiced alphabet subtraction items in short lag and long lag conditions. After practice, half of the participants were immediately tested and the other half were tested after a 7-day delay. Results indicate that the lag effect on the durability of memory-based automaticity is primarily due to interference. We discuss potential modification of current memory-based processing theories to account for these effects. © 2013.

  20. Cognitive declines in healthy aging: evidence from multiple aspects of interference resolution.

    PubMed

    Pettigrew, Corinne; Martin, Randi C

    2014-06-01

    The present study tested the hypothesis that older adults show age-related deficits in interference resolution, also referred to as inhibitory control. Although oftentimes considered as a unitary aspect of executive function, various lines of work support the notion that interference resolution may be better understood as multiple constructs, including resistance to proactive interference (PI) and response-distractor inhibition (e.g., Friedman & Miyake, 2004). Using this dichotomy, the present study assessed whether older adults (relative to younger adults) show impaired performance across both, 1, or neither of these interference resolution constructs. To do so, we used multiple tasks to tap each construct and examined age effects at both the single task and latent variable levels. Older adults consistently demonstrated exaggerated interference effects across resistance to PI tasks. Although the results for the response-distractor inhibition tasks were less consistent at the individual task level analyses, age effects were evident on multiple tasks, as well as at the latent variable level. However, results of the latent variable modeling suggested declines in interference resolution are best explained by variance that is common to the 2 interference resolution constructs measured herein. Furthermore, the effect of age on interference resolution was found to be both distinct from declines in working memory, and independent of processing speed. These findings suggest multiple cognitive domains are independently sensitive to age, but that declines in the interference resolution constructs measured herein may originate from a common cause. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  1. Does an attention bias to appetitive and aversive words modulate interference control in youth with ADHD?

    PubMed

    Ma, Ili; Mies, Gabry W; Lambregts-Rommelse, Nanda N J; Buitelaar, Jan K; Cillessen, Antonius H N; Scheres, Anouk

    2018-05-01

    Interference control refers to the ability to selectively attend to certain information while ignoring distracting information. This ability can vary as a function of distractor relevance. Distractors that are particularly relevant to an individual may attract more attention than less relevant distractors. This is referred to as attention bias. Weak interference control and altered reward sensitivity are both important features of attention deficit hyperactivity disorder (ADHD). However, interference control is typically studied in isolation. This study integrates both. Youths (aged 9 to 17 years) with ADHD (n = 37, 25 boys) and typically-developing controls (n = 38, 20 boys) completed a Stroop task using appetitive words and matched neutral words to assess whether appetitive distractors diminished interference control more in youths with ADHD than controls. In order to test for specificity, aversive words were also included. As expected, appetitive words disrupted interference control but this effect was not stronger for youths with ADHD than the controls. Aversive words, on the other hand, facilitated interference control. Dimensional analyses revealed that this facilitation effect increased substantially as a function of ADHD symptom severity. Possible mechanisms for this effect include up-regulation of interference control as a function of induced negative mood, or as a function of increased effort. In conclusion, appetitive words do not lead to worse interference control in youths with ADHD compared with controls. Interference control was modulated in a valence-specific manner, concurrent with mood-induced effects on cognitive control.

  2. When Prior Knowledge Interferes, Inhibitory Control Matters for Learning: The Case of Numerical Magnitude Representations

    ERIC Educational Resources Information Center

    Laski, Elida V.; Dulaney, Alana

    2015-01-01

    The present study tested the "interference hypothesis"-that learning and using more advanced representations and strategies requires the inhibition of prior, less advanced ones. Specifically, it examined the relation between inhibitory control and number line estimation performance. Experiment 1 compared the accuracy of adults' (N = 53)…

  3. Differential Distraction Effects in Short-Term and Long-Term Retention of Pictures and Words

    ERIC Educational Resources Information Center

    Pellegrino, James W.; And Others

    1976-01-01

    Comparisons between recall levels following simple acoustic or visual tasks and the simultaneous visual-plus-acoustic task are not based upon equivalent amounts of interference within each modality. This research attempts to test more precisely the relationship between visual and acoustic interference by using a sequential rather than a…

  4. Activation of host immune responses in neonatal calves and interference with TB diagnostics after immunization with a commercial heat-killed vaccine

    USDA-ARS?s Scientific Manuscript database

    A major drawback of current whole-cell vaccines for Mycobacterium avium subsp. paratuberculosis is the potential interference with diagnostic tests for bovine tuberculosis and paratuberculosis. The current study was designed to explore cross-reactivity of the current USDA commercial vaccine for MAP ...

  5. Activation of host immune responses in neonatal calves and interference with TB diagnostics after immunization with a commercial heat-killed vaccine

    USDA-ARS?s Scientific Manuscript database

    A major drawback of current whole-cell vaccines for Mycobacterium avium subsp. paratuberculosis (MAP) is the potential interference with diagnostic tests for bovine tuberculosis and paratuberculosis. The current study was designed to explore cross-reactivity of the current USDA commercial vaccine fo...

  6. Forgetting in Immediate Serial Recall: Decay, Temporal Distinctiveness, or Interference?

    ERIC Educational Resources Information Center

    Oberauer, Klaus; Lewandowsky, Stephan

    2008-01-01

    Three hypotheses of forgetting from immediate memory were tested: time-based decay, decreasing temporal distinctiveness, and interference. The hypotheses were represented by 3 models of serial recall: the primacy model, the SIMPLE (scale-independent memory, perception, and learning) model, and the SOB (serial order in a box) model, respectively.…

  7. The Crosstalk Hypothesis: Why Language Interferes with Driving

    ERIC Educational Resources Information Center

    Bergen, Benjamin; Medeiros-Ward, Nathan; Wheeler, Kathryn; Drews, Frank; Strayer, David

    2013-01-01

    Performing two cognitive tasks at the same time can degrade performance for either domain-general reasons (e.g., both tasks require attention) or domain-specific reasons (e.g., both tasks require visual working memory). We tested predictions of these two accounts of interference on the task of driving while using language, a naturally occurring…

  8. False Negatives, Canter's Background Interference Procedure, the Trail Making Test, and Epileptics.

    ERIC Educational Resources Information Center

    McKinzey, Ronald K.; And Others

    1985-01-01

    Results of correlation studies of 141 adult epileptics' scores on the Background Interference Procedure (BIP) indicated that the BIP often does not agree with abnormal neurological diagnoses but often does agree with psychiatric diagnoses of Organic Brain Syndrome (OBS). Suggests that future BIP validity studies include a behavioral measure of OBS…

  9. The electromagnetic interference of mobile phones on the function of a γ-camera.

    PubMed

    Javadi, Hamid; Azizmohammadi, Zahra; Mahmoud Pashazadeh, Ali; Neshandar Asli, Isa; Moazzeni, Taleb; Baharfar, Nastaran; Shafiei, Babak; Nabipour, Iraj; Assadi, Majid

    2014-03-01

    The aim of the present study is to evaluate whether or not the electromagnetic field generated by mobile phones interferes with the function of a SPECT γ-camera during data acquisition. We tested the effects of 7 models of mobile phones on 1 SPECT γ-camera. The mobile phones were tested when making a call, in ringing mode, and in standby mode. The γ-camera function was assessed during data acquisition from a planar source and a point source of Tc with activities of 10 mCi and 3 mCi, respectively. A significant visual decrease in count number was considered to be electromagnetic interference (EMI). The percentage of induced EMI with the γ-camera per mobile phone was in the range of 0% to 100%. The incidence of EMI was mainly observed in the first seconds of ringing and then mitigated in the following frames. Mobile phones are portable sources of electromagnetic radiation, and there is interference potential with the function of SPECT γ-cameras leading to adverse effects on the quality of the acquired images.

  10. Evaluation of Wall Interference Effects in a Two-Dimensional Transonic Wind Tunnel by Subsonic Linear Theory,

    DTIC Science & Technology

    1979-02-01

    tests were conducted on two geometrica lly similar models of each of two aerofoil sections -—t he NA CA 00/ 2 and the BGK- 1 sections -and covered a...and slotted-wall tes t sections are corrected for wind tunnel wall interference efJ~cts by the application of classical linearized theory. For the...solid wall results , these corrections appear to produce data which are very close to being free of the effects of interference. In the case of

  11. Interference from previous distraction disrupts older adults' memory.

    PubMed

    Biss, Renée K; Campbell, Karen L; Hasher, Lynn

    2013-07-01

    Previously relevant information can disrupt the ability of older adults to remember new information. Here, the researchers examined whether prior irrelevant information, or distraction, can also interfere with older adults' memory for new information. Younger and older adults first completed a 1-back task on pictures that were superimposed with distracting words. After a delay, participants learned picture-word paired associates and memory was tested using picture-cued recall. In 1 condition (high interference), some pairs included pictures from the 1-back task now paired with new words. In a low-interference condition, the transfer list used all new items. Older adults had substantially lower cued-recall performance in the high- compared with the low-interference condition. In contrast, younger adults' performance did not vary across conditions. These findings suggest that even never-relevant information from the past can disrupt older adults' memory for new associations.

  12. Interference between light and heavy neutrinos for 0 νββ decay in the left–right symmetric model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, Fahim; Neacsu, Andrei; Horoi, Mihai

    Neutrinoless double-beta decay is proposed as an important low energy phenomenon that could test beyond the Standard Model physics. There are several potentially competing beyond the Standard Model mechanisms that can induce the process. It thus becomes important to disentangle the different processes. In the present study we consider the interference effect between the light left-handed and heavy right-handed Majorana neutrino exchange mechanisms. The decay rate, and consequently, the phase-space factors for the interference term are derived, based on the left–right symmetric model. The numerical values for the interference phase-space factors for several nuclides are calculated, taking into consideration themore » relativistic Coulomb distortion of the electron wave function and finite-size of the nucleus. As a result, the variation of the interference effect with the Q-value of the process is studied.« less

  13. Interferometric Shack-Hartmann wavefront sensor with an array of four-hole apertures.

    PubMed

    López, David; Ríos, Susana

    2010-04-20

    A modified Hartmann test based on the interference produced by a four-hole mask can be used to measure an unknown wavefront. To scan the wavefront, the interference pattern is measured for different positions of the mask. The position of the central fringe of the diamond-shaped interference pattern gives a measure of the local wavefront slopes. Using a set of four-hole apertures located behind an array of lenslets in such a way that each four-hole window is inside one lenslet area, a set of four-hole interference patterns can be obtained in the back focal plane of the lenslets without having to scan the wavefront. The central fringe area of each interference pattern is narrower than the area of the central maximum of the diffraction pattern of the lenslet, increasing the accuracy in the estimate of the lobe position as compared with the Shack-Hartmann wavefront sensor.

  14. Proactive interference from items previously stored in visual working memory.

    PubMed

    Makovski, Tal; Jiang, Yuhong V

    2008-01-01

    This study investigates the fate of information that was previously stored in visual working memory but that is no longer needed. Previous research has found inconsistent results, with some showing effective release of irrelevant information and others showing proactive interference. Using change detection tasks of colors or shapes, we show that participants tend to falsely classify a changed item as "no change" if it matches one of the memory items on the preceding trial. The interference is spatially specific: Memory for the preceding trial interferes more if it matches the feature value and the location of a test item than if it does not. Interference results from retaining information in visual working memory, since it is absent when items on the preceding trials are passively viewed, or are attended but not memorized. We conclude that people cannot fully eliminate unwanted visual information from current working memory tasks.

  15. Interference between light and heavy neutrinos for 0 νββ decay in the left–right symmetric model

    DOE PAGES

    Ahmed, Fahim; Neacsu, Andrei; Horoi, Mihai

    2017-03-31

    Neutrinoless double-beta decay is proposed as an important low energy phenomenon that could test beyond the Standard Model physics. There are several potentially competing beyond the Standard Model mechanisms that can induce the process. It thus becomes important to disentangle the different processes. In the present study we consider the interference effect between the light left-handed and heavy right-handed Majorana neutrino exchange mechanisms. The decay rate, and consequently, the phase-space factors for the interference term are derived, based on the left–right symmetric model. The numerical values for the interference phase-space factors for several nuclides are calculated, taking into consideration themore » relativistic Coulomb distortion of the electron wave function and finite-size of the nucleus. As a result, the variation of the interference effect with the Q-value of the process is studied.« less

  16. Investigation of RF Emissions From Wireless Networks as a Threat to Avionic Systems

    NASA Technical Reports Server (NTRS)

    Salud, Maria Theresa P.; Williams, Reuben A. (Technical Monitor)

    2002-01-01

    The paper focuses on understanding and obtaining preliminary measurements of radiated field (RF) emissions of laptop/wireless local area network (WLAN) systems. This work is part of a larger research project to measure radiated emissions of wireless devices to provide a better understanding for potential interference with crucial aircraft avionics systems. A reverberation chamber data collection process is included, as well as recommendations for additional tests. Analysis of measurements from devices under test (DUTs) proved inconclusive for addressing potential interference issues. Continued effort is expected to result in a complete easily reproducible test protocol. The data and protocol presented here are considered preliminary.

  17. Ronchi test for characterization of nanofocusing optics at a hard x-ray free-electron laser.

    PubMed

    Nilsson, Daniel; Uhlén, Fredrik; Holmberg, Anders; Hertz, Hans M; Schropp, Andreas; Patommel, Jens; Hoppe, Robert; Seiboth, Frank; Meier, Vivienne; Schroer, Christian G; Galtier, Eric; Nagler, Bob; Lee, Hae Ja; Vogt, Ulrich

    2012-12-15

    We demonstrate the use of the classical Ronchi test to characterize aberrations in focusing optics at a hard x-ray free-electron laser. A grating is placed close to the focus and the interference between the different orders after the grating is observed in the far field. Any aberrations in the beam or the optics will distort the interference fringes. The method is simple to implement and can provide single-shot information about the focusing quality. We used the Ronchi test to measure the aberrations in a nanofocusing Fresnel zone plate at the Linac Coherent Light Source at 8.194 keV.

  18. Understanding the Transfer Deficit: Contextual Mismatch, Proactive Interference, and Working Memory Affect Toddlers' Video-Based Transfer.

    PubMed

    Choi, Koeun; Kirkorian, Heather L; Pempek, Tiffany A

    2017-04-17

    Researchers tested the impact of contextual mismatch, proactive interference, and working memory (WM) on toddlers' transfer across contexts. Forty-two toddlers (27-34 months) completed four object-retrieval trials, requiring memory updating on Trials 2-4. Participants watched hiding events on a tablet computer. Search performance was tested using another tablet (match) or a felt board (mismatch). WM was assessed. On earlier search trials, WM predicted transfer in both conditions, and toddlers in the match condition outperformed those in the mismatch condition; however, the benefit of contextual match and WM decreased over trials. Contextual match apparently increased proactive interference on later trials. Findings are interpreted within existing accounts of the transfer deficit, and a combined account is proposed. © 2017 The Authors. Child Development © 2017 Society for Research in Child Development, Inc.

  19. Electromagnetic interference from GSM and TETRA phones with life-support medical devices.

    PubMed

    Hietanen, Maila; Sibakov, Viktor

    2007-01-01

    Disturbances in hospital devices caused by cellular telephone signals were investigated. The interference sources were GSM900, GSM1800, and TETRA380 phones. The number of medical appliances tested was 23. Most measurements were taken in a semi-anechoic laboratory. To simulate the worst situation, the phones were adjusted to emit at their maximum power levels. No interference was observed if the distance from GSM1800 phone was over 5 cm. Corresponding safety distance for GSM900 phone was 70 cm, and for TETRA phones over 3 m. Hence, the use of GSM1800 type mobile phones can be considered safe, whereas GSM 900 and TETRA phones may cause considerable interference in hospital devices, which can result in life-endangering situations.

  20. Radiated Emissions Test Approach

    DOT National Transportation Integrated Search

    2015-10-02

    1. Draft Department of Transportation (DOT) Test Plan to Develop : Interference Tolerance Masks for GNSS Receivers in the L1 : Radiofrequency Band (1559 1610 MHz) provides high level : overview of radiated emissions test setup : 2. Presenta...

  1. The effect of breath freshener strips on two types of breath alcohol testing instruments.

    PubMed

    Moore, Ronald L; Guillen, Jennifer

    2004-07-01

    The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.

  2. Measurement environments and testing

    NASA Astrophysics Data System (ADS)

    Marvin, A. C.

    1991-06-01

    The various methods used to assess both the emission (interference generation) performance of electronic equipment and the immunity of electronic equipment to external electromagnetic interference are described. The measurement methods attempt to simulate realistic operating conditions for the equipment being tested, yet at the same time they must be repeatable and practical to operate. This has led to the development of a variety of test methods, each of which has its limitations. Concentration is on the most common measurement methods such as open-field test sites, screened enclosures and transverse electromagnetic (TEM) cells. The physical justification for the methods, their limitations, and measurement precision are described. Ways of relating similar measurements made by different methods are discussed, and some thoughts on future measurement improvements are presented.

  3. Sensors Locate Radio Interference

    NASA Technical Reports Server (NTRS)

    2009-01-01

    After receiving a NASA Small Business Innovation Research (SBIR) contract from Kennedy Space Center, Soneticom Inc., based in West Melbourne, Florida, created algorithms for time difference of arrival and radio interferometry, which it used in its Lynx Location System (LLS) to locate electromagnetic interference that can disrupt radio communications. Soneticom is collaborating with the Federal Aviation Administration (FAA) to install and test the LLS at its field test center in New Jersey in preparation for deploying the LLS at commercial airports. The software collects data from each sensor in order to compute the location of the interfering emitter.

  4. Observations of interference between portable particle counters and NOx monitors

    NASA Astrophysics Data System (ADS)

    Bereznicki, Sarah D.; Kamal, Ali

    2013-08-01

    Studies in environmental exposure science have developed a preference for smaller devices that can be easily co-located without need for gas standards, such as those instruments utilized in the Near-road Exposures and Effects from Urban Air Pollutants Study (NEXUS). One observation from NEXUS was the potential for instrument interference from alcohol-based particle counters on photometric-based nitrogen oxide (NOx) monitors. This article reports the findings from laboratory tests replicating enclosed-shelter monitoring configurations and operation cycles for a common photometric-based NOx monitor and a widely used alcohol-based particle counter. These tests monitored the NOx response while the particle counter sampling interval and ambient airflow rate were varied to (1) confirm that proximity between the instruments induced interferences, (2) identify any dependencies in NOx monitor recovery on ambient airflow, and (3) determine the time needed for the NOx monitor to recover to pre-interference levels under different atmospheric conditions. During particle counter operations, NOx concentrations responded instantaneously with a several-fold jump above the measurement baseline. When the particle counter was operated for more than 10 min, this interference period also showed a marked decline in the NOx baseline. The overall recovery time of the NOx monitor depended less on the time of particle counter operation, and more on the speed of ambient airflow. If photometric-based NOx monitors need to be operated alongside alcohol-based particle counters, mechanisms must be employed to exhaust alcohol-based vapors from enclosed monitoring environments. Given the strong evidence for interference, however, it is recommended these devices not be operated within close proximity to one another.

  5. Training Alters the Resolution of Lexical Interference: Evidence for Plasticity of Competition and Inhibition

    PubMed Central

    Kapnoula, Efthymia C.; McMurray, Bob

    2016-01-01

    Language learning is generally described as a problem of acquiring new information (e.g., new words). However, equally important are changes in how the system processes known information. For example, a wealth of studies has suggested dramatic changes over development in how efficiently children recognize familiar words, but it is unknown what kind of experience-dependent mechanisms of plasticity give rise to such changes in real-time processing. We examined the plasticity of the language processing system by testing whether a fundamental aspect of spoken word recognition, lexical interference, can be altered by experience. Adult participants were trained on a set of familiar words over a series of 4 tasks. In the high-competition (HC) condition, tasks were designed to encourage coactivation of similar words (e.g., net and neck) and to require listeners to resolve this competition. Tasks were similar in the low-competition (LC) condition, but did not enhance this competition. Immediately after training, interlexical interference was tested using a visual world paradigm task. Participants in the HC group resolved interference to a fuller degree than those in the LC group, demonstrating that experience can shape the way competition between words is resolved. TRACE simulations showed that the observed late differences in the pattern of interference resolution can be attributed to differences in the strength of lexical inhibition. These findings inform cognitive models in many domains that involve competition/interference processes, and suggest an experience-dependent mechanism of plasticity that may underlie longer term changes in processing efficiency associated with both typical and atypical development. PMID:26709587

  6. Public access defibrillation: suppression of 16.7 Hz interference generated by the power supply of the railway systems.

    PubMed

    Christov, Ivaylo I; Iliev, Georgi L

    2005-03-15

    A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well.

  7. Early life factors initiate a 'vicious circle' of affective and gastrointestinal symptoms: A longitudinal study.

    PubMed

    Jones, Michael P; Oudenhove, Lukas Van; Koloski, Natasha; Tack, Jan; Talley, Nicholas J

    2013-10-01

    Functional gastrointestinal disorders (FGID) have been shown to be associated with both comorbid mood disorders and traumatic events such as abuse earlier in life. In a longitudinal study, we tested a model that hypothesized: (i) childhood abuse was associated with subsequent mood disorder and pain or interference in life by bowel symptoms both directly and indirectly via neurotic personality; and (ii) an ongoing cycle of mood disorder impacts on bowel symptoms. Subjects from the general population classified as irritable bowel syndrome and/or functional dyspepsia (IBS/FD, n = 207) or free of FGID (n = 100) were prospectively studied every 6 months over 18 months. In addition to bowel symptom interference and abdominal pain, measures of personality (neuroticism), childhood abuse history, depression, and anxiety were obtained. The hypothesized model was tested via Path Modelling. Childhood abuse was found to be directly associated with neuroticism but only indirectly associated with baseline interference and mood disorders (via neuroticism). The data further supported an ongoing cycle of elevations in mood disorders and pain/interference by bowel symptoms. The data supported direct effects of interference at one time point on interference at the subsequent time point in addition to indirect effects of prior anxiety and depression. Repeating the model with pain frequency as the outcome yielded almost identical findings which suggests the findings are generalized across domains of symptoms and quality-of-life. Our data provide support for a model characterized by a 'vicious circle' between mood disorders and FGID symptoms in adulthood, with initial input from early life factors.

  8. Counting statistics of many-particle quantum walks

    NASA Astrophysics Data System (ADS)

    Mayer, Klaus; Tichy, Malte C.; Mintert, Florian; Konrad, Thomas; Buchleitner, Andreas

    2011-06-01

    We study quantum walks of many noninteracting particles on a beam splitter array as a paradigmatic testing ground for the competition of single- and many-particle interference in a multimode system. We derive a general expression for multimode particle-number correlation functions, valid for bosons and fermions, and infer pronounced signatures of many-particle interferences in the counting statistics.

  9. RNA interference as a method for target-site screening in the Western Corn Rootworm, Diabrotica virgifera virgifera

    USDA-ARS?s Scientific Manuscript database

    RNA interference (RNAi) is one of the most powerful and extraordinarily-specific means by which to silence genes. The ability of RNAi to silence genes makes it possible to ascertain function from genomic data, thereby making it an excellent choice for target-site screening. To test the efficacy of...

  10. The Critical Role of Retrieval Processes in Release from Proactive Interference

    ERIC Educational Resources Information Center

    Bauml, Karl-Heinz T.; Kliegl, Oliver

    2013-01-01

    Proactive interference (PI) refers to the finding that memory for recently studied (target) information can be vastly impaired by the previous study of other (nontarget) information. PI can be reduced in a number of ways, for instance, by directed forgetting of the prior nontarget information, the testing of the prior nontarget information, or an…

  11. The Picture-Word Interference Paradigm: Grammatical Class Effects in Lexical Production

    ERIC Educational Resources Information Center

    De Simone, Flavia; Collina, Simona

    2016-01-01

    Four picture-word interference experiments aimed to test the role of grammatical class in lexical production. In Experiment 1 target nouns and verbs were produced in presence of semantically unrelated distractors that could also be nouns and verbs. Participants were slower when the distractor was of the same grammatical category of the target. To…

  12. Task Interference in Time-Based, Event-Based, and Dual Intention Prospective Memory Conditions

    ERIC Educational Resources Information Center

    Hicks, Jason L.; Marsh, Richard L.; Cook, Gabriel I.

    2005-01-01

    Forming the intention to complete an activity later is the standard definition of a prospective memory task. Recently, a debate has arisen concerning the degree to which near-term intentions usurp resources away from other ongoing activities. In four experiments the authors tested how much interference was caused by holding a variety of different…

  13. Contributions to singing ability by the posterior portion of the superior temporal gyrus of the non-language-dominant hemisphere: First evidence from subdural cortical stimulation, Wada testing, and fMRI

    PubMed Central

    Suarez, Ralph O.; Golby, Alexandra; Whalen, Stephen; Sato, Susumu; Theodore, William H.; Kufta, Conrad V.; Devinsky, Orrin; Balish, Marshall; Bromfield, Edward B.

    2009-01-01

    INTRODUCTION Although the substrates that mediate singing abilities in the human brain are not well understood, invasive brain mapping techniques used for clinical decision making such as intracranial electrocortical testing and Wada testing offer a rare opportunity to examine music-related function in a select group of subjects, affording exceptional spatial and temporal specificity. METHODS We studied eight patients with medically refractory epilepsy undergoing indwelling subdural electrode seizure focus localization. All patients underwent Wada testing for language lateralization. Functional assessment of language and music tasks was done by electrode grid cortical stimulation. One patient was also tested non-invasively with functional MRI. Functional organization of singing ability compared to language ability was determined based on four regions-ofinterest: left and right inferior frontal gyrus (IFG), and left and right posterior superior temporal gyrus (pSTG). RESULTS In some subjects, electrical stimulation of dominant pSTG can interfere with speech and not singing, whereas stimulation of non-dominant pSTG area can interfere with singing and not speech. Stimulation of the dominant IFG tends to interfere with both musical and language expression, while non-dominant IFG stimulation was often observed to cause no interference with either task; and finally, that stimulation of areas adjacent to but not within non-dominant pSTG typically does not affect either ability. FMRI mappings of one subject revealed similar music/language dissociation with respect to activation asymmetry within the regions-of-interest. CONCLUSION Despite inherent limitations with respect to strictly research objectives, invasive clinical techniques offer a rare opportunity to probe musical and language cognitive processes of the brain in a select group of patients. PMID:19570530

  14. Discrimination performance in aging is vulnerable to interference and dissociable from spatial memory

    PubMed Central

    Johnson, Sarah A.; Sacks, Patricia K.; Turner, Sean M.; Gaynor, Leslie S.; Ormerod, Brandi K.; Maurer, Andrew P.; Bizon, Jennifer L.

    2016-01-01

    Hippocampal-dependent episodic memory and stimulus discrimination abilities are both compromised in the elderly. The reduced capacity to discriminate between similar stimuli likely contributes to multiple aspects of age-related cognitive impairment; however, the association of these behaviors within individuals has never been examined in an animal model. In the present study, young and aged F344×BN F1 hybrid rats were cross-characterized on the Morris water maze test of spatial memory and a dentate gyrus-dependent match-to-position test of spatial discrimination ability. Aged rats showed overall impairments relative to young in spatial learning and memory on the water maze task. Although young and aged learned to apply a match-to-position response strategy in performing easy spatial discriminations within a similar number of trials, a majority of aged rats were impaired relative to young in performing difficult spatial discriminations on subsequent tests. Moreover, all aged rats were susceptible to cumulative interference during spatial discrimination tests, such that error rate increased on later trials of test sessions. These data suggest that when faced with difficult discriminations, the aged rats were less able to distinguish current goal locations from those of previous trials. Increasing acetylcholine levels with donepezil did not improve aged rats’ abilities to accurately perform difficult spatial discriminations or reduce their susceptibility to interference. Interestingly, better spatial memory abilities were not significantly associated with higher performance on difficult spatial discriminations. This observation, along with the finding that aged rats made more errors under conditions in which interference was high, suggests that match-to-position spatial discrimination performance may rely on extra-hippocampal structures such as the prefrontal cortex, in addition to the dentate gyrus. PMID:27317194

  15. Development And Test of A Digitally Steered Antenna Array for The Navigator GPS Receiver

    NASA Technical Reports Server (NTRS)

    Pinto, Heitor David; Valdez, Jennifer E.; Winternitz, Luke M. B.; Hassouneh, Munther A.; Price, Samuel R.

    2012-01-01

    Global Positioning System (GPS)-based navigation has become common for low-Earth orbit spacecraft as the signal environment is similar to that on the Earth s surface. The situation changes abruptly, however, for spacecraft whose orbital altitudes exceed that of the GPS constellation. Visibility is dramatically reduced and signals that are present may be very weak and more susceptible to interference. GPS receivers effective at these altitudes require increased sensitivity, which often requires a high-gain antenna. Pointing such an antenna can pose a challenge. One efficient approach to mitigate these problems is the use of a digitally steered antenna array. Such an antenna can optimally allocate gain toward desired signal sources and away from interferers. This paper presents preliminary results in the development and test of a digitally steered antenna array for the Navigator GPS research program at NASA s Goddard Space Flight Center. In particular, this paper highlights the development of an array and front-end electronics, the development and test of a real-time software GPS receiver, and implementation of three beamforming methods for combining the signals from the array. Additionally, this paper discusses the development of a GPS signal simulator which produces digital samples of the GPS L1C/A signals as they would be received by an arbitrary antenna array configuration. The simulator models transmitter and receiver dynamics, near-far and multipath interference, and has been a critical component in both the development and test of the GPS receiver. The GPS receiver system was tested with real and simulated GPS signals. Preliminary results show that performance improvement was achieved in both the weak signal and interference environments, matching analytical predictions. This paper summarizes our initial findings and discusses the advantages and limitations of the antenna array and the various beamforming methods.

  16. Test report: Electron-proton spectrometer qualification test unit, qualification test

    NASA Technical Reports Server (NTRS)

    Vincent, D. L.

    1972-01-01

    Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.

  17. Increased sensitivity to proactive and retroactive interference in amnestic mild cognitive impairment: new insights.

    PubMed

    Hanseeuw, Bernard J; Seron, Xavier; Ivanoiu, Adrian

    2012-10-01

    Increased sensitivity to proactive (PI) and retroactive (RI) interference has been observed in amnestic mild cognitive impairment (aMCI). PI and RI are often explained as being the result of a response competition mechanism. However, patients with aMCI are supposed to suffer mostly from encoding deficits. We hypothesized that in aMCI interference may occur at encoding and not only at the retrieval stage. We developed an original paradigm enabling PI and RI to be tested with and without response competitors. Eighteen young controls (YC), 16 elderly controls (EC) and 15 aMCI participated in the study. The YC and EC groups presented interference effects only in conditions that included a direct response competitor. In contrast, aMCI had interference effects in all conditions including the one without response competitor. Increased sensitivity to interference in aMCI appears to occur at the encoding/consolidation stage and not only at the retrieval stage, as is the case in healthy subjects. This result is discussed in the context of the associative encoding deficits characterizing aMCI. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site.

    PubMed

    Fetter, J G; Benditt, D G; Stanton, M S

    1996-08-01

    This study was designed to determine the susceptibility of an implanted cardioverter-defibrillator to electromagnetic interference in an electrically hostile work site environment, with the ultimate goal of allowing the patient to return to work. Normal operation of an implanted cardioverter-defibrillator depends on reliable sensing of the heart's electrical activity. Consequently, there is concern that external electromagnetic interference from external sources in the work place, especially welding equipment or motor-generator systems, may be sensed and produce inappropriate shocks or abnormal reed switch operation, temporarily suspending detection of ventricular tachycardia or ventricular fibrillation. The effects of electromagnetic interference on the operation of one type of implantable cardioverter-defibrillator (Medtronic models 7217 and 7219) was measured by using internal event counter monitoring in 10 patients operating arc welders at up to 900 A or working near 200-hp motors and 1 patient close to a locomotive starter drawing up to 400 A. The electromagnetic interference produced two sources of potential interference on the sensing circuit or reed switch operation, respectively: 1) electrical fields with measured frequencies up to 50 MHz produced by the high currents during welding electrode activation, and 2) magnetic fields produced by the current in the welding electrode and cable. The defibrillator sensitivity was programmed to the highest (most sensitive) value: 0.15 mV (model 7219) or 0.3 mV (model 7217). The ventricular tachycardia and ventricular fibrillation therapies were temporarily turned off but the detection circuits left on. None of the implanted defibrillators tested were affected by oversensing of the electric field as verified by telemetry from the detection circuits. The magnetic field from 225-A welding current produced a flux density of 1.2 G; this density was not adequate to close the reed switch, which requires approximately 10 G. Our testing at the work site revealed no electrical interference with this type of defibrillator. Patients were allowed to return to work. The following precautions should be observed by the patient: 1) maintain a minimal distance of 2 ft (61 cm) from the welding arc and cables or large motors, 2) do not exceed tested currents with the welding equipment, 3) wear insulated gloves while operating electrical equipment, 4) verify that electrical equipment is properly grounded, and 5) stop welding and leave the work area immediately if a therapy is delivered or a feeling of lightheadedness is experienced.

  19. Sample processing approach for detection of ricin in surface samples.

    PubMed

    Kane, Staci; Shah, Sanjiv; Erler, Anne Marie; Alfaro, Teneile

    2017-12-01

    With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. The procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required. Published by Elsevier B.V.

  20. Memory, priority encoding, and overcoming high-value proactive interference in younger and older adults.

    PubMed

    Friedman, Michael C; Castel, Alan D

    2013-01-01

    It is often necessary to remember important information while directing attention away from encoding less valuable information. To examine how aging influences the ability to control and update the encoding of high-value information, younger and older adults studied six lists of words that varied in terms of the point values associated with each word. The words were paired with the same high and low point values for three study-test cycles, but on the fourth and subsequent cycles the value-word pairings were switched such that the lowest value pairs became the highest values (and vice versa). For the first three study-test cycles, younger adults outperformed older adults in terms of the number of words recalled and overall point totals, but performance was similar in terms of selectively remembering high-value words. When the values were switched, both groups displayed substantial interference from the previous pairings. Although both groups improved with additional study-test cycles, only younger adults were able to fully recover from the interference effects. A similar, and more pronounced, set of results were obtained when positive and negative point values were paired with the words. The findings are interpreted in a value-directed remembering framework, emphasizing the role of benefits and costs of strategic encoding and age-related differences in the effects of interference on memory.

  1. Experimental study of pressure and heating rate on a swept cylindrical leading edge resulting from swept shock wave interference. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Glass, Christopher E.

    1989-01-01

    The effects of cylindrical leading edge sweep on surface pressure and heat transfer rate for swept shock wave interference were investigated. Experimental tests were conducted in the Calspan 48-inch Hypersonic Shock Tunnel at a nominal Mach number of 8, nominal unit Reynolds number of 1.5 x 10 to the 6th power per foot, leading edge and incident shock generator sweep angles of 0, 15, and 30 deg, and incident shock generator angle-of-attack fixed at 12.5 deg. Detailed surface pressure and heat transfer rate on the cylindircal leading edge of a swept shock wave interference model were measured at the region of the maximum surface pressure and heat transfer rate. Results show that pressure and heat transfer rate on the cylindrical leading edge of the shock wave interference model were reduced as the sweep was increased over the range of tested parameters. Peak surface pressure and heat transfer rate on the cylinder were about 10 and 30 times the undisturbed flow stagnation point value, respectively, for the 0 deg sweep test. A comparison of the 15 and 30 deg swept results with the 0 deg swept results showed that peak pressure was reduced about 13 percent and 44 percent, respectively, and peak heat transfer rate was reduced about 7 percent and 27 percent, respectively.

  2. Appetitive context conditioning proactively, but transiently, interferes with expression of counterconditioned context fear

    PubMed Central

    Holmes, Nathan M.

    2014-01-01

    Four experiments used rats to study appetitive–aversive transfer. Rats trained to eat a palatable food in a distinctive context and shocked in that context ate and did not freeze when tested 1 d later but froze and did not eat when tested 14 d later. These results were associatively mediated (Experiments 1 and 2), observed when rats were or were not food deprived (Experiments 1 and 2), and were not due to latent inhibition (Experiment 3). In contrast, rats trained to eat in the context and shocked there 13 d later froze and did not eat when tested 1 d after the shocked exposure. However, rats that received an additional eating session in the context 1 d before the shocked exposure ate and did not freeze when tested 1 d after the shocked exposure (Experiment 4). The results show that appetitive conditioning transiently interferes with aversive conditioning. They are discussed in terms of a weak context–shock association becoming stronger with the lapse of time (so-called fear incubation) or of the interference by the context–food association becoming weaker with the lapse of time. PMID:25320352

  3. A wall interference assessment/correction system

    NASA Technical Reports Server (NTRS)

    Lo, Ching F.; Overby, Glenn; Qian, Cathy X.; Sickles, W. L.; Ulbrich, N.

    1992-01-01

    A Wall Signature method originally developed by Hackett has been selected to be adapted for the Ames 12-ft Wind Tunnel WIAC system in the project. This method uses limited measurements of the static pressure at the wall, in conjunction with the solid wall boundary condition, to determine the strength and distribution of singularities representing the test article. The singularities are used in turn for estimating blockage wall interference. The lifting interference will be treated separately by representing in a horseshoe vortex system for the model's lifting effects. The development and implementation of a working prototype will be completed, delivered and documented with a software manual. The WIAC code will be validated by conducting numerically simulated experiments rather than actual wind tunnel experiments. The simulations will be used to generate both free-air and confined wind-tunnel flow fields for each of the test articles over a range of test configurations. Specifically, the pressure signature at the test section wall will be computed for the tunnel case to provide the simulated 'measured' data. These data will serve as the input for the WIAC method--Wall Signature method. The performance of the WIAC method then may be evaluated by comparing the corrected data with those of the free-air simulation.

  4. Non-Interfering Effects of Active Post-Encoding Tasks on Episodic Memory Consolidation in Humans

    PubMed Central

    Varma, Samarth; Takashima, Atsuko; Krewinkel, Sander; van Kooten, Maaike; Fu, Lily; Medendorp, W. Pieter; Kessels, Roy P. C.; Daselaar, Sander M.

    2017-01-01

    So far, studies that investigated interference effects of post-learning processes on episodic memory consolidation in humans have used tasks involving only complex and meaningful information. Such tasks require reallocation of general or encoding-specific resources away from consolidation-relevant activities. The possibility that interference can be elicited using a task that heavily taxes our limited brain resources, but has low semantic and hippocampal related long-term memory processing demands, has never been tested. We address this question by investigating whether consolidation could persist in parallel with an active, encoding-irrelevant, minimally semantic task, regardless of its high resource demands for cognitive processing. We distinguish the impact of such a task on consolidation based on whether it engages resources that are: (1) general/executive, or (2) specific/overlapping with the encoding modality. Our experiments compared subsequent memory performance across two post-encoding consolidation periods: quiet wakeful rest and a cognitively demanding n-Back task. Across six different experiments (total N = 176), we carefully manipulated the design of the n-Back task to target general or specific resources engaged in the ongoing consolidation process. In contrast to previous studies that employed interference tasks involving conceptual stimuli and complex processing demands, we did not find any differences between n-Back and rest conditions on memory performance at delayed test, using both recall and recognition tests. Our results indicate that: (1) quiet, wakeful rest is not a necessary prerequisite for episodic memory consolidation; and (2) post-encoding cognitive engagement does not interfere with memory consolidation when task-performance has minimal semantic and hippocampally-based episodic memory processing demands. We discuss our findings with reference to resource and reactivation-led interference theories. PMID:28424596

  5. Real-time Java simulations of multiple interference dielectric filters

    NASA Astrophysics Data System (ADS)

    Kireev, Alexandre N.; Martin, Olivier J. F.

    2008-12-01

    An interactive Java applet for real-time simulation and visualization of the transmittance properties of multiple interference dielectric filters is presented. The most commonly used interference filters as well as the state-of-the-art ones are embedded in this platform-independent applet which can serve research and education purposes. The Transmittance applet can be freely downloaded from the site http://cpc.cs.qub.ac.uk. Program summaryProgram title: Transmittance Catalogue identifier: AEBQ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEBQ_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 5778 No. of bytes in distributed program, including test data, etc.: 90 474 Distribution format: tar.gz Programming language: Java Computer: Developed on PC-Pentium platform Operating system: Any Java-enabled OS. Applet was tested on Windows ME, XP, Sun Solaris, Mac OS RAM: Variable Classification: 18 Nature of problem: Sophisticated wavelength selective multiple interference filters can include some tens or even hundreds of dielectric layers. The spectral response of such a stack is not obvious. On the other hand, there is a strong demand from application designers and students to get a quick insight into the properties of a given filter. Solution method: A Java applet was developed for the computation and the visualization of the transmittance of multilayer interference filters. It is simple to use and the embedded filter library can serve educational purposes. Also, its ability to handle complex structures will be appreciated as a useful research and development tool. Running time: Real-time simulations

  6. Non-Interfering Effects of Active Post-Encoding Tasks on Episodic Memory Consolidation in Humans.

    PubMed

    Varma, Samarth; Takashima, Atsuko; Krewinkel, Sander; van Kooten, Maaike; Fu, Lily; Medendorp, W Pieter; Kessels, Roy P C; Daselaar, Sander M

    2017-01-01

    So far, studies that investigated interference effects of post-learning processes on episodic memory consolidation in humans have used tasks involving only complex and meaningful information. Such tasks require reallocation of general or encoding-specific resources away from consolidation-relevant activities. The possibility that interference can be elicited using a task that heavily taxes our limited brain resources, but has low semantic and hippocampal related long-term memory processing demands, has never been tested. We address this question by investigating whether consolidation could persist in parallel with an active, encoding-irrelevant, minimally semantic task, regardless of its high resource demands for cognitive processing. We distinguish the impact of such a task on consolidation based on whether it engages resources that are: (1) general/executive, or (2) specific/overlapping with the encoding modality. Our experiments compared subsequent memory performance across two post-encoding consolidation periods: quiet wakeful rest and a cognitively demanding n-Back task. Across six different experiments (total N = 176), we carefully manipulated the design of the n-Back task to target general or specific resources engaged in the ongoing consolidation process. In contrast to previous studies that employed interference tasks involving conceptual stimuli and complex processing demands, we did not find any differences between n-Back and rest conditions on memory performance at delayed test, using both recall and recognition tests. Our results indicate that: (1) quiet, wakeful rest is not a necessary prerequisite for episodic memory consolidation; and (2) post-encoding cognitive engagement does not interfere with memory consolidation when task-performance has minimal semantic and hippocampally-based episodic memory processing demands. We discuss our findings with reference to resource and reactivation-led interference theories.

  7. Does altercentric interference rely on mentalizing?: Results from two level-1 perspective-taking tasks

    PubMed Central

    Gollwitzer, Anton; Santos, Laurie R.

    2018-01-01

    Considerable debate has focused on whether adults possess an implicit system for representing others’ mental states. Some argue that people automatically represent the perspective of others using evidence from altercentric interference—cases in which another agent’s perspective affects the speed with which one can report one’s own perspective. Others have argued that altercentric interference is not always specific to social stimuli and thus may represent a simpler process such as submentalizing. To distinguish between these positions, Study 1 developed a novel measure of altercentric interference—a “sandbox” measure—that allowed us to more sensitively assess altercentric interference across social and non-social conditions. We replicated previous findings showing that participants experience both egocentric and altercentric interference, but we found that these effects emerge equally in social and non-social conditions. To further test whether altercentric interference emerges in social perspective-taking situations, Study 2 conducted a conceptual replication of a study which used a novel “goggle” paradigm to assess whether individuals implicitly represent others’ perspectives. Although we failed to find evidence of altercentric interference in response times, participants’ accuracy reflected the possibility of interference from others’ perspectives. We argue that these findings provide support for the idea that altercentric interference in response to social stimuli (an avatar) is driven by perspective-taking mechanisms, while such interference in response to non-social stimuli (an arrow) is driven by attention-cuing mechanisms. PMID:29566019

  8. EMC Test Report: StangSat - CubeSat Program

    NASA Technical Reports Server (NTRS)

    Carmody, Lynne M.; Aragona, Peter S.

    2013-01-01

    This report documents the Electromagnetic Interference E M I testing performed on the StangSat; the unit under test (UUT). Testing was per the requirements of MIL STD-461F. The UUT was characterized and passed the radiated emissions (RE102 limit for Spacecraft) testing.

  9. Mathematical Modelling of Allelopathy: IV. Assessment of Contributions of Competition and Allelopathy to Interference by Barley

    PubMed Central

    Liu, De Li; An, Min; Johnson, I.R.; Lovett, J.V.

    2005-01-01

    One of the main challenges to the research on allelopathy is technically the separation of allelopathic effect from competition, and quantitatively, the assessment of the contribution of each component to overall interference. A simple mathematical model is proposed to calculate the contribution of allelopathy and competition to interference. As an example of applying the quantitative model to interference by barley (Hordeum vulgare cv. Triumph), the approach used was an addition of allelopathic effect, by an equivalent amount, to the environment of the test plant (white mustard, Sinapis alba), rather than elimination of competition. Experiments were conducted in glasshouse to determine the magnitude of the contributions of allelopathy and competition to interference by barley. The leachates of living barley roots significantly reduced the total dry weight of white mustard. The model involved the calculation of adjusted densities to an equivalent basis for modelling the contribution of allelopathy and competition to total interference. The results showed that allelopathy contributed 40%, 37% and 43% to interference by barley at 6, 12 and 18 white mustard pot−1. The consistency in magnitude of the calculated contribution of allelopathic effect by barley across various densities of receiver plant suggested that the adjusted equivalent density is effective and that the model is able to assess the contribution of each component of interference regardless of the density of receiver plant. PMID:19330162

  10. Analysis of Quantum Information Test-Bed by Parametric Down-Converted Photons Interference Measurement

    NASA Technical Reports Server (NTRS)

    To, Wing H.

    2005-01-01

    Quantum optical experiments require all the components involved to be extremely stable relative to each other. The stability can be "measured" by using an interferometric experiment. A pair of coherent photons produced by parametric down-conversion could be chosen to be orthogonally polarized initially. By rotating the polarization of one of the wave packets, they can be recombined at a beam splitter such that interference will occur. Theoretically, the interference will create four terms in the wave function. Two terms with both photons going to the same detector, and two terms will have the photons each going to different detectors. However, the latter will cancel each other out, thus no photons will arrive at the two detectors simultaneously under ideal conditions. The stability Of the test-bed can then be inferred by the dependence of coincidence count on the rotation angle.

  11. A methodology to enhance electromagnetic compatibility in joint military operations

    NASA Astrophysics Data System (ADS)

    Buckellew, William R.

    The development and validation of an improved methodology to identify, characterize, and prioritize potential joint EMI (electromagnetic interference) interactions and identify and develop solutions to reduce the effects of the interference are discussed. The methodology identifies potential EMI problems using results from field operations, historical data bases, and analytical modeling. Operational expertise, engineering analysis, and testing are used to characterize and prioritize the potential EMI problems. Results can be used to resolve potential EMI during the development and acquisition of new systems and to develop engineering fixes and operational workarounds for systems already employed. The analytic modeling portion of the methodology is a predictive process that uses progressive refinement of the analysis and the operational electronic environment to eliminate noninterfering equipment pairs, defer further analysis on pairs lacking operational significance, and resolve the remaining EMI problems. Tests are conducted on equipment pairs to ensure that the analytical models provide a realistic description of the predicted interference.

  12. Visibility-Based Hypothesis Testing Using Higher-Order Optical Interference

    NASA Astrophysics Data System (ADS)

    Jachura, Michał; Jarzyna, Marcin; Lipka, Michał; Wasilewski, Wojciech; Banaszek, Konrad

    2018-03-01

    Many quantum information protocols rely on optical interference to compare data sets with efficiency or security unattainable by classical means. Standard implementations exploit first-order coherence between signals whose preparation requires a shared phase reference. Here, we analyze and experimentally demonstrate the binary discrimination of visibility hypotheses based on higher-order interference for optical signals with a random relative phase. This provides a robust protocol implementation primitive when a phase lock is unavailable or impractical. With the primitive cost quantified by the total detected optical energy, optimal operation is typically reached in the few-photon regime.

  13. An experimental study of several wind tunnel wall configurations using two V/STOL model configurations. [low speed wind tunnels

    NASA Technical Reports Server (NTRS)

    Binion, T. W., Jr.

    1975-01-01

    Experiments were conducted in the low speed wind tunnel using two V/STOL models, a jet-flap and a jet-in-fuselage configuration, to search for a wind tunnel wall configuration to minimize wall interference on V/STOL models. Data were also obtained on the jet-flap model with a uniform slotted wall configuration to provide comparisons between theoretical and experimental wall interference. A test section configuration was found which provided some data in reasonable agreement with interference-free results over a wide range of momentum coefficients.

  14. Radio Frequency Interference Detection for Passive Remote Sensing Using Eigenvalue Analysis

    NASA Technical Reports Server (NTRS)

    Schoenwald, Adam J.; Kim, Seung-Jun; Mohammed, Priscilla N.

    2017-01-01

    Radio frequency interference (RFI) can corrupt passive remote sensing measurements taken with microwave radiometers. With the increasingly utilized spectrum and the push for larger bandwidth radiometers, the likelihood of RFI contamination has grown significantly. In this work, an eigenvalue-based algorithm is developed to detect the presence of RFI and provide estimates of RFI-free radiation levels. Simulated tests show that the proposed detector outperforms conventional kurtosis-based RFI detectors in the low-to-medium interference-to-noise-power-ratio (INR) regime under continuous wave (CW) and quadrature phase shift keying (QPSK) RFIs.

  15. Sensitivity Study of the Wall Interference Correction System (WICS) for Rectangular Tunnels

    NASA Technical Reports Server (NTRS)

    Walker, Eric L.; Everhart, Joel L.; Iyer, Venkit

    2001-01-01

    An off-line version of the Wall Interference Correction System (WICS) has been implemented for the NASA Langley National Transonic Facility. The correction capability is currently restricted to corrections for solid wall interference in the model pitch plane for Mach numbers less than 0.45 due to a limitation in tunnel calibration data. A study to assess output sensitivity to measurement uncertainty was conducted to determine standard operational procedures and guidelines to ensure data quality during the testing process. Changes to the current facility setup and design recommendations for installing the WICS code into a new facility are reported.

  16. Electrical interference in non-competitive pacemakers

    PubMed Central

    Sowton, E.; Gray, K.; Preston, T.

    1970-01-01

    Patients with 41 implanted non-competitive pacemakers were investigated. A variety of domestic electrical equipment, a motor-car, and a physiotherapy diathermy apparatus were each operated in turn at various ranges from the patient. Interference effects on pacemaker function were assessed on the electrocardiograph. Medtronic demand 5841 pacemakers were stopped by diathermy while Cordis Ectocor pacemakers developed a fast discharge rate. Cordis triggered pacemakers (both Atricor and Ectocor) were sensitive to interference from many items of domestic equipment and the motor car. The Elema EM153 ran at an increased rate when an electric razor was running close to the pacemaker. The Devices demand 2980 and the Medtronic demand 5841 were not affected by the domestic equipment tested. The significance of interference effects is discussed in relation to pacemaker design. Images PMID:5470044

  17. Using an interference spectrum as a short-range absolute rangefinder with fiber and wideband source

    NASA Astrophysics Data System (ADS)

    Hsieh, Tsung-Han; Han, Pin

    2018-06-01

    Recently, a new type of displacement instrument using spectral-interference has been found, which utilizes fiber and a wideband light source to produce an interference spectrum. In this work, we develop a method that measures the absolute air-gap distance by taking wavelengths at two interference spectra minima. The experimental results agree with the theoretical calculations. It is also utilized to produce and control the spectral switch, which is much easier than other previous methods using other control mechanisms. A scanning mode of this scheme for stepped surface measurement is suggested, which is verified by a standard thickness gauge test. Our scheme is different to one available on the market that may use a curve-fitting method, and some comparisons are made between our scheme and that one.

  18. Interference Analysis Status and Plans for Aeronautical Mobile Airport Communications System (AeroMACS)

    NASA Technical Reports Server (NTRS)

    Kerczewski, Robert J.; Wilson, Jeffrey D.

    2010-01-01

    Interference issues related to the operation of an aeronautical mobile airport communications system (AeroMACS) in the C-Band (specifically 5091-5150 MHz) is being investigated. The issue of primary interest is co-channel interference from AeroMACS into mobile-satellite system (MSS) feeder uplinks. The effort is focusing on establishing practical limits on AeroMACS transmissions from airports so that the threshold of interference into MSS is not exceeded. The analyses are being performed with the software package Visualyse Professional, developed by Transfinite Systems Limited. Results with omni-directional antennas and plans to extend the models to represent AeroMACS more accurately will be presented. These models should enable realistic analyses of emerging AeroMACS designs to be developed from NASA Test Bed, RTCA 223, and European results.

  19. “The Relationship between Executive Functioning, Processing Speed and White Matter Integrity in Multiple Sclerosis”

    PubMed Central

    Genova, Helen M.; DeLuca, John; Chiaravalloti, Nancy; Wylie, Glenn

    2014-01-01

    The primary purpose of the current study was to examine the relationship between performance on executive tasks and white matter integrity, assessed by diffusion tensor imaging (DTI) in Multiple Sclerosis (MS). A second aim was to examine how processing speed affects the relationship between executive functioning and FA. This relationship was examined in two executive tasks that rely heavily on processing speed: the Color-Word Interference Test and Trail-Making Test (Delis-Kaplan Executive Function System). It was hypothesized that reduced fractional anisotropy (FA) is related to poor performance on executive tasks in MS, but that this relationship would be affected by the statistical correction of processing speed from the executive tasks. 15 healthy controls and 25 persons with MS participated. Regression analyses were used to examine the relationship between executive functioning and FA, both before and after processing speed was removed from the executive scores. Before processing speed was removed from the executive scores, reduced FA was associated with poor performance on Color-Word Interference Test and Trail-Making Test in a diffuse network including corpus callosum and superior longitudinal fasciculus. However, once processing speed was removed, the relationship between executive functions and FA was no longer significant on the Trail Making test, and significantly reduced and more localized on the Color-Word Interference Test. PMID:23777468

  20. Construction of a 2- by 2-foot transonic adaptive-wall test section at the NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Morgan, Daniel G.; Lee, George

    1986-01-01

    The development of a new production-size, two-dimensional, adaptive-wall test section with ventilated walls at the NASA Ames Research Center is described. The new facility incorporates rapid closed-loop operation, computer/sensor integration, and on-line interference assessment and wall corrections. Air flow through the test section is controlled by a series of plenum compartments and three-way slide vales. A fast-scan laser velocimeter was built to measure velocity boundary conditions for the interference assessment scheme. A 15.2-cm- (6.0-in.-) chord NACA 0012 airfoil model will be used in the first experiments during calibration of the facility.

  1. Wind tunnel and analytical investigation of over-the-wing propulsion/air frame interferences for a short-haul aircraft at Mach numbers from 0.6 to 0.78. [conducted in the Lewis 8 by 6 foot tunnel

    NASA Technical Reports Server (NTRS)

    Wells, O. D.; Lopez, M. L.; Welge, H. R.; Henne, P. A.; Sewell, A. E.

    1977-01-01

    Results of analytical calculations and wind tunnel tests at cruise speeds of a representative four engine short haul aircraft employing upper surface blowing (USB) with a supercritical wing are discussed. Wind tunnel tests covered a range of Mach number M from 0.6 to 0.78. Tests explored the use of three USB nozzle configurations. Results are shown for the isolated wing body and for each of the three nozzle types installed. Experimental results indicate that a low angle nacelle and streamline contoured nacelle yielded the same interference drag at the design Mach number. A high angle powered lift nacelle had higher interference drag primarily because of nacelle boattail low pressures and flow separation. Results of varying the spacing between the nacelles and the use of trailing edge flap deflections, wing upper surface contouring, and a convergent-divergent nozzle to reduce potential adverse jet effects were also discussed. Analytical comparisons with experimental data, made for selected cases, indicate favorable agreement.

  2. Methods for assessing wall interference in the 2- by 2-foot adaptive-wall wind tunnel

    NASA Technical Reports Server (NTRS)

    Schairer, E. T.

    1986-01-01

    Discussed are two methods for assessing two-dimensional wall interference in the adaptive-wall test section of the NASA Ames 2 x 2-Foot Transonic Wind Tunnel: (1) a method for predicting free-air conditions near the walls of the test section (adaptive-wall methods); and (2) a method for estimating wall-induced velocities near the model (correction methods), both of which methods are based on measurements of either one or two components of flow velocity near the walls of the test section. Each method is demonstrated using simulated wind tunnel data and is compared with other methods of the same type. The two-component adaptive-wall and correction methods were found to be preferable to the corresponding one-component methods because: (1) they are more sensitive to, and give a more complete description of, wall interference; (2) they require measurements at fewer locations; (3) they can be used to establish free-stream conditions; and (4) they are independent of a description of the model and constants of integration.

  3. Strut and wall interference on jet-induced ground effects of a STOVL aircraft in hover

    NASA Technical Reports Server (NTRS)

    Kristy, Michael H.

    1995-01-01

    A small scale ground effect test rig was used to study the ground plane flow field generated by a STOVL aircraft in hover. The objective of the research was to support NASA-Ames Research Center planning for the Large Scale Powered Model (LSPM) test for the ARPA-sponsored ASTOVL program. Specifically, small scale oil flow visualization studies were conducted to make a relative assessment of the aerodynamic interference of a proposed strut configuration and a wall configuration on the ground plane stagnation line. A simplified flat plate model representative of a generic jet-powered STOVL aircraft was used to simulate the LSPM. Cold air jets were used to simulate both the lift fan and the twin rear engines. Nozzle Pressure Ratios were used that closely represented those used on the LSPM tests. The flow visualization data clearly identified a shift in the stagnation line location for both the strut and the wall configuration. Considering the experimental uncertainty, it was concluded that either the strut configuration o r the wall configuration caused only a minor aerodynamic interference.

  4. Specific Relationships between Job Demands, Job Resources and Psychological Outcomes and the Mediating Role of Negative Work-Home Interference

    ERIC Educational Resources Information Center

    Janssen, Peter P. M.; Peeters, Maria C. W.; de Jonge, Jan; Houkes, Inge; Tummers, Gladys E. R.

    2004-01-01

    This study among 115 US and 260 Dutch nurses and nurse assistants tested a theoretically derived model of specific relationships between work characteristics and two theoretically distinct outcomes (i.e., emotional exhaustion and job satisfaction). Furthermore, the mediating role of negative work-home interference (NWI) in this context was…

  5. RESEARCH NOTE: INTERFERENCES DUE TO OZONE-SCAVENGING REAGENTS IN THE GC-ECD DETERMINATION OF ALDEHYDES AND KETONS AS THE O-(2,3,4,5,6-PENTAFLUOROBENZYL)OXIMES

    EPA Science Inventory

    Six potential ozone-scavenging reagents were tested for possible interference in the GC-ECD determination of aldehydes and ketones after derivatization with O-(2,3,4,5,6-pentafluorobenzyl)oxylamine (PFBOA). All six-nitrite, cynaide, methanoate (formate), indigo-55'-disulfonate d...

  6. Cognitive control of familiarity: directed forgetting reduces proactive interference in working memory.

    PubMed

    Festini, Sara B; Reuter-Lorenz, Patricia A

    2014-03-01

    Proactive interference (PI) occurs when previously learned information interferes with new learning. In a working memory task, PI induces longer response times and more errors to recent negative probes than to new probes, presumably because the recent probe's familiarity invites a "yes" response. Warnings, longer intertrial intervals, and the increased contextual salience of the probes can reduce but not eliminate PI, suggesting that cognitive control over PI is limited. Here we tested whether control exerted in the form of intentional forgetting performed during working memory can reduce the magnitude of PI. In two experiments, participants performed a working memory task with directed-forgetting instructions and the occasional presentation of recent probes. Surprise long-term memory testing indicated better memory for to-be-remembered than for to-be-forgotten items, documenting the classic directed-forgetting effect. Critically, in working memory, PI was virtually eliminated for recent probes from prior to-be-forgotten lists, as compared to recent probes from prior to-be-remembered lists. Thus cognitive control, when executed via directed forgetting, can reduce the adverse and otherwise persistent interference from familiarity, an effect that we attribute to attenuated memory representations of the to-be-forgotten items.

  7. Drug Target Interference in Immunogenicity Assays: Recommendations and Mitigation Strategies.

    PubMed

    Zhong, Zhandong Don; Clements-Egan, Adrienne; Gorovits, Boris; Maia, Mauricio; Sumner, Giane; Theobald, Valerie; Wu, Yuling; Rajadhyaksha, Manoj

    2017-11-01

    Sensitive and specific methodology is required for the detection and characterization of anti-drug antibodies (ADAs). High-quality ADA data enables the evaluation of potential impact of ADAs on the drug pharmacokinetic profile, patient safety, and efficacious response to the drug. Immunogenicity assessments are typically initiated at early stages in preclinical studies and continue throughout the drug development program. One of the potential bioanalytical challenges encountered with ADA testing is the need to identify and mitigate the interference mediated by the presence of soluble drug target. A drug target, when present at sufficiently high circulating concentrations, can potentially interfere with the performance of ADA and neutralizing antibody (NAb) assays, leading to either false-positive or, in some cases, false-negative ADA and NAb assay results. This publication describes various mechanisms of assay interference by soluble drug target, as well as strategies to recognize and mitigate such target interference. Pertinent examples are presented to illustrate the impact of target interference on ADA and NAb assays as well as several mitigation strategies, including the use of anti-target antibodies, soluble versions of the receptors, target-binding proteins, lectins, and solid-phase removal of targets. Furthermore, recommendations for detection and mitigation of such interference in different formats of ADA and NAb assays are provided.

  8. Reciprocal relationships between value orientation and motivational interference during studying and leisure.

    PubMed

    Hofer, Manfred; Schmid, Sebastian; Fries, Stefan; Kilian, Britta; Kuhnle, Claudia

    2010-12-01

    Motivational interference is defined as the amount of impairment in a target activity due to the incentives of a non-chosen attractive alternative. The amount to which pupils experience motivational interference while studying or while performing a leisure activity in a school-leisure conflict situation is seen as depending on the values they attach to achievement and well-being. At the same time, values may also be effects of frequent experience of motivational interference in the respective areas. The study is aimed at investigating the reciprocal relationship between personal value orientations and the experience of motivational interference during studying and leisure. A total of 363 pupils (sixth to eighth graders at the time of first measurement) completed the same questionnaire twice in a 2-year interval. The questionnaire included measures of achievement and well-being value orientation and the experience of motivational interference during studying and during leisure in school-leisure conflicts. For this, two scenarios were created. In regression analyses, achievement and well-being value orientations as well as their interaction terms were used as predictors for experience of motivational interference at t(2) while controlling for experience of motivational interference at t(1), and vice versa. Additionally in path models, these relations were tested in an integrative way. Pupils' achievement value orientations were connected to differential changes in experiencing motivational interference during leisure and during studying in one scenario but only for pupils low or medium in well-being value orientation. Conversely, experience of motivational interference at t(1) was related to changes in value orientations 2 years later. High motivational interference during studying led to an increase in well-being value orientation, while high motivational interference during leisure was followed by a decrease in well-being value orientation and an increase in achievement value orientation. Overall, path models supported these results. The results are discussed in terms of value change and are linked to self-control and motivation research.

  9. Adaptive receiver structures for asynchronous CDMA systems

    NASA Astrophysics Data System (ADS)

    Rapajic, Predrag B.; Vucetic, Branka S.

    1994-05-01

    Adaptive linear and decision feedback receiver structures for coherent demodulation in asynchronous code division multiple access (CDMA) systems are considered. It is assumed that the adaptive receiver has no knowledge of the signature waveforms and timing of other users. The receiver is trained by a known training sequence prior to data transmission and continuously adjusted by an adaptive algorithm during data transmission. The proposed linear receiver is as simple as a standard single-user detector receiver consisting of a matched filter with constant coefficients, but achieves essential advantages with respect to timing recovery, multiple access interference elimination, near/far effect, narrowband and frequency-selective fading interference suppression, and user privacy. An adaptive centralized decision feedback receiver has the same advantages of the linear receiver but, in addition, achieves a further improvement in multiple access interference cancellation at the expense of higher complexity. The proposed receiver structures are tested by simulation over a channel with multipath propagation, multiple access interference, narrowband interference, and additive white Gaussian noise.

  10. The effects of acute stress and perceptual load on distractor interference.

    PubMed

    Sato, Hirotsune; Takenaka, Ippei; Kawahara, Jun I

    2012-01-01

    Selective attention can be improved under conditions in which a high perceptual load is assumed to exhaust cognitive resources, leaving scarce resources for distractor processing. The present study examined whether perceptual load and acute stress share common attentional resources by manipulating perceptual and stress loads. Participants identified a target within an array of nontargets that were flanked by compatible or incompatible distractors. Attentional selectivity was measured by longer reaction times in response to the incompatible than to the compatible distractors. Participants in the stress group participated in a speech test that increased anxiety and threatened self-esteem. The effect of perceptual load interacted with the stress manipulation in that participants in the control group demonstrated an interference effect under the low perceptual load condition, whereas such interference disappeared under the high perceptual load condition. Importantly, the stress group showed virtually no interference under the low perceptual load condition, whereas substantial interference occurred under the high perceptual load condition. These results suggest that perceptual and stress related demands consume the same attentional resources.

  11. Conversion of umbilical arterial Doppler waveforms to cardiac cycle triggering signals: a preparatory study for online motion-gated three-dimensional fetal echocardiography.

    PubMed

    Deng, J; Birkett, A G; Kalache, K D; Hanson, M A; Peebles, D M; Linney, A D; Lees, W R; Rodeck, C H

    2001-01-01

    To remove motion artefacts, a device was built to convert "noisy" umbilical arterial Doppler waveforms (UADWs) from an ultrasound (US) system into sharp ECG R-wave-like cardiac cycle triggering signals (CCTSs). These CCTSs were then used to gate a simultaneous (online) 3-D acquisition of sectional fetal echocardiograms from another US system. To test the conversion performance, a study was carried out in sheep fetal twins. Pulmonary arterial flow waveforms (PAFWs) from implanted probes were traced, in the meantime, to determine the reference cardiac cycle. Interference caused by running the two nonsynchronised US systems was controlled to three degrees (not-noticeable, moderate, and severe), together with high (> or = 40 cm/s) and low (< 40) flow velocities on UADWs. The conversion efficiency, assessed by the percentage of UADWs converted into CCTSs, was in the range of 83% to 100% for not-noticeable and moderate interference, and 0% to 71% for severe interference. The triggering accuracy, assessed by [(time lag mean between the onsets of PAFWs and corresponding CCTSs) -- (its 99% confidence level)] / the mean, was 90% to 96% for the not-noticeable interference high- and low-flow groups and for the moderate interference high-flow group; 19% to 93% for the moderate interference low-flow group; and from not obtainable up to 90% for the severe interference groups. The results show that UADWs can be used as a satisfactory online motion-gating source even in the presence of moderate interference. The major problems are from severe interference or moderate interference with low-flow velocity, which can be minimised/eliminated by the integration of the individual systems involved.

  12. Sleep Shelters Verbal Memory from Different Kinds of Interference

    PubMed Central

    Sheth, Bhavin R.; Varghese, Reni; Truong, Thuy

    2012-01-01

    Study Objectives: Studies have shown that sleep shelters old verbal memories from associative interference arising from new, more recently acquired memories. Our objective is to extend the forms of interference for which sleep provides a sheltering benefit to non-associative and prospective interference, and to examine experimental conditions and memory strengths for which sleep before or after learning particularly affects verbal memory consolidation. Design: Acquiring paired word associates, retention across intervening sleep and wake, training on new, interfering word associates, and test recall of both sets. Setting: University laboratory. Participants: Healthy volunteers. Interventions: N/A. Measurements and Results: Comparing recall before and after intervening periods of sleep versus wake, we found that: (i) Sleep preferentially shields weakly encoded verbal memories from retroactive interference. (ii) Sleep immediately following learning helps shelter memory from associative and non-associative forms of retroactive interference. (iii) Sleep protects new verbal memories from prospective interference. (iv) Word associations acquired for the first time in the evening after a day spent in the wake state are encoded more strongly than word associations acquired in the morning following a night of sleep. Conclusions: The findings extend the known sleep protection from interference to non-associative as well as prospective interference, and limit the protection to weakly encoded word associations. Combined, our results suggest that sleep immediately after verbal learning isolates newly formed memory traces and renders them inaccessible, except by specific contextual cues. Memory isolation in sleep is a passive mechanism that can reasonably account for several experimental findings. Citation: Sheth BR; Varghese R; Truong T. Sleep shelters verbal memory from different kinds of interference. SLEEP 2012;35(7):985-996. PMID:22754045

  13. Calibration and Validation of the Dutch-Flemish PROMIS Pain Interference Item Bank in Patients with Chronic Pain

    PubMed Central

    Crins, Martine H. P.; Roorda, Leo D.; Smits, Niels; de Vet, Henrica C. W.; Westhovens, Rene; Cella, David; Cook, Karon F.; Revicki, Dennis; van Leeuwen, Jaap; Boers, Maarten; Dekker, Joost; Terwee, Caroline B.

    2015-01-01

    The Dutch-Flemish PROMIS Group translated the adult PROMIS Pain Interference item bank into Dutch-Flemish. The aims of the current study were to calibrate the parameters of these items using an item response theory (IRT) model, to evaluate the cross-cultural validity of the Dutch-Flemish translations compared to the original English items, and to evaluate their reliability and construct validity. The 40 items in the bank were completed by 1085 Dutch chronic pain patients. Before calibrating the items, IRT model assumptions were evaluated using confirmatory factor analysis (CFA). Items were calibrated using the graded response model (GRM), an IRT model appropriate for items with more than two response options. To evaluate cross-cultural validity, differential item functioning (DIF) for language (Dutch vs. English) was examined. Reliability was evaluated based on standard errors and Cronbach’s alpha. To evaluate construct validity correlations with scores on legacy instruments (e.g., the Disabilities of the Arm, Shoulder and Hand Questionnaire) were calculated. Unidimensionality of the Dutch-Flemish PROMIS Pain Interference item bank was supported by CFA tests of model fit (CFI = 0.986, TLI = 0.986). Furthermore, the data fit the GRM and showed good coverage across the pain interference continuum (threshold-parameters range: -3.04 to 3.44). The Dutch-Flemish PROMIS Pain Interference item bank has good cross-cultural validity (only two out of 40 items showing DIF), good reliability (Cronbach’s alpha = 0.98), and good construct validity (Pearson correlations between 0.62 and 0.75). A computer adaptive test (CAT) and Dutch-Flemish PROMIS short forms of the Dutch-Flemish PROMIS Pain Interference item bank can now be developed. PMID:26214178

  14. Calibration and Validation of the Dutch-Flemish PROMIS Pain Interference Item Bank in Patients with Chronic Pain.

    PubMed

    Crins, Martine H P; Roorda, Leo D; Smits, Niels; de Vet, Henrica C W; Westhovens, Rene; Cella, David; Cook, Karon F; Revicki, Dennis; van Leeuwen, Jaap; Boers, Maarten; Dekker, Joost; Terwee, Caroline B

    2015-01-01

    The Dutch-Flemish PROMIS Group translated the adult PROMIS Pain Interference item bank into Dutch-Flemish. The aims of the current study were to calibrate the parameters of these items using an item response theory (IRT) model, to evaluate the cross-cultural validity of the Dutch-Flemish translations compared to the original English items, and to evaluate their reliability and construct validity. The 40 items in the bank were completed by 1085 Dutch chronic pain patients. Before calibrating the items, IRT model assumptions were evaluated using confirmatory factor analysis (CFA). Items were calibrated using the graded response model (GRM), an IRT model appropriate for items with more than two response options. To evaluate cross-cultural validity, differential item functioning (DIF) for language (Dutch vs. English) was examined. Reliability was evaluated based on standard errors and Cronbach's alpha. To evaluate construct validity correlations with scores on legacy instruments (e.g., the Disabilities of the Arm, Shoulder and Hand Questionnaire) were calculated. Unidimensionality of the Dutch-Flemish PROMIS Pain Interference item bank was supported by CFA tests of model fit (CFI = 0.986, TLI = 0.986). Furthermore, the data fit the GRM and showed good coverage across the pain interference continuum (threshold-parameters range: -3.04 to 3.44). The Dutch-Flemish PROMIS Pain Interference item bank has good cross-cultural validity (only two out of 40 items showing DIF), good reliability (Cronbach's alpha = 0.98), and good construct validity (Pearson correlations between 0.62 and 0.75). A computer adaptive test (CAT) and Dutch-Flemish PROMIS short forms of the Dutch-Flemish PROMIS Pain Interference item bank can now be developed.

  15. Early life factors initiate a ‘vicious circle’ of affective and gastrointestinal symptoms: A longitudinal study

    PubMed Central

    Van Oudenhove, Lukas; Koloski, Natasha; Tack, Jan; Talley, Nicholas J

    2013-01-01

    Objective Functional gastrointestinal disorders (FGID) have been shown to be associated with both comorbid mood disorders and traumatic events such as abuse earlier in life. In a longitudinal study, we tested a model that hypothesized: (i) childhood abuse was associated with subsequent mood disorder and pain or interference in life by bowel symptoms both directly and indirectly via neurotic personality; and (ii) an ongoing cycle of mood disorder impacts on bowel symptoms. Design Subjects from the general population classified as irritable bowel syndrome and/or functional dyspepsia (IBS/FD, n = 207) or free of FGID (n = 100) were prospectively studied every 6 months over 18 months. In addition to bowel symptom interference and abdominal pain, measures of personality (neuroticism), childhood abuse history, depression, and anxiety were obtained. The hypothesized model was tested via Path Modelling. Results Childhood abuse was found to be directly associated with neuroticism but only indirectly associated with baseline interference and mood disorders (via neuroticism). The data further supported an ongoing cycle of elevations in mood disorders and pain/interference by bowel symptoms. The data supported direct effects of interference at one time point on interference at the subsequent time point in addition to indirect effects of prior anxiety and depression. Repeating the model with pain frequency as the outcome yielded almost identical findings which suggests the findings are generalized across domains of symptoms and quality-of-life. Conclusion Our data provide support for a model characterized by a ‘vicious circle’ between mood disorders and FGID symptoms in adulthood, with initial input from early life factors. PMID:24917988

  16. Public access defibrillation: Suppression of 16.7 Hz interference generated by the power supply of the railway systems

    PubMed Central

    Christov, Ivaylo I; Iliev, Georgi L

    2005-01-01

    Background A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. Methods Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. Results The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. Conclusion The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well. PMID:15766390

  17. Experiences with a high-blockage model tested in the NASA Ames 12-foot pressure wind tunnel

    NASA Technical Reports Server (NTRS)

    Coder, D. W.

    1984-01-01

    Representation of the flow around full-scale ships was sought in the subsonic wind tunnels in order to a Hain Reynolds numbers as high as possible. As part of the quest to attain the largest possible Reynolds number, large models with high blockage are used which result in significant wall interference effects. Some experiences with such a high blockage model tested in the NASA Ames 12-foot pressure wind tunnel are summarized. The main results of the experiment relating to wind tunnel wall interference effects are also presented.

  18. Innovative signal processing for Johnson Noise thermometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ezell, N. Dianne Bull; Britton, Jr, Charles L.; Roberts, Michael

    This report summarizes the newly developed algorithm that subtracted the Electromagnetic Interference (EMI). The EMI performance is very important to this measurement because any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Two methods of removing EMI were developed and tested at various locations. This report also summarizes the testing performed at different facilities outside Oak Ridge National Laboratory using both EMI removal techniques. The first EMI removal technique reviewed in previous milestone reports and therefore this report will detail the second method.

  19. Lecture Series on Electromagnetic Interference and Electromagnetic Compatibility Presented on 10-11 June 1991 in Kjeller, Norway, 13-14 June 1991 in Konigswinter, Germany and 17-18 June 1991 in Lisbon, Portugal.

    DTIC Science & Technology

    1991-06-01

    assessing EMC characteristics of EM systems in a lecture on "Measuremazzenvironments and testing".The various test en - vronments available will be described...severe in a dual-diversity system gains at least 10 dB in SNR relative to a maritime situation where salt water corrosion has for many non-diversity...environment having great significance for NATO systems are: (a) electromagnetic interference (EMT) arising from both natural and man-made sources; (b

  20. Testing enhances subsequent learning in older but not in younger elementary school children.

    PubMed

    Aslan, Alp; Bäuml, Karl-Heinz T

    2016-11-01

    In adults, testing can enhance subsequent learning by reducing interference from the tested information. Here, we examined this forward effect of testing in children. Younger and older elementary school children and adult controls studied four lists of items in anticipation of a final cumulative recall test. Following presentation of each of the first three lists, participants were immediately tested on the respective list, or the list was re-presented for additional study. Results revealed that, compared to additional study, immediate testing of Lists 1-3 enhanced memory for the subsequently studied List 4 in adults and older elementary school children, but not in younger elementary school children. The findings indicate that the forward effect of testing is a relatively late-maturing phenomenon that develops over middle childhood and is still inefficient in the early elementary school years. Together with the results of other recent studies, these findings point to a more general problem in young children in combating interference. © 2015 John Wiley & Sons Ltd.

  1. Engineering Tests for Energy Storage Cars at the Transportation Test Center : Volume 2. Performance, Power Consumption and Radio Frequency Interference Tests

    DOT National Transportation Integrated Search

    1977-05-01

    The primary purpose of the tests documented herein was to demonstrate the principles and feasibility of an energy-storage-type propulsion system, and its adaptability to an existing car design. The test program comprised four phases of tests on two N...

  2. Blood Glucose Monitoring Devices

    MedlinePlus

    ... of interferences ability to transmit data to a computer cost of the meter cost of the test ... Performance FDA expands indication for continuous glucose monitoring system, first to replace fingerstick testing for diabetes treatment ...

  3. Evidence for selective inhibitory impairment in individuals with autism spectrum disorder.

    PubMed

    Christ, Shawn E; Kester, Lindsay E; Bodner, Kimberly E; Miles, Judith H

    2011-11-01

    The social and communicative challenges faced by individuals with autism spectrum disorder (ASD) are often compounded by additional difficulties with executive function. It remains unclear, however, to what the extent individuals with ASD experienced impairment in inhibitory control. The objective of the present study was to assess the three main subtypes of executive inhibitory control within a single ASD sample thus providing new insight into the unique ASD-related pattern of sparing and impairment observed across different aspects of inhibitory control. A sample of 28 children with ASD (mean age = 13.1 years) and a comparison group of 49 neurologically uncompromised children (mean age = 13.3 years) participated. A prepotent response inhibition task, a flanker visual filtering task, and a proactive interference memory task were used to evaluate prepotent response inhibition, resistance to distracter interference, and resistance to proactive interference, respectively. After accounting for individual differences in noninhibition abilities (e.g., processing speed) and overall level of functioning, there was no evidence of group-related differences in inhibitory performance on the prepotent response inhibition test or proactive interference test. ASD-related impairments in inhibitory control were evident, however, on the flanker visual filtering task. Taken together, the present findings indicate that ASD is associated with impairments in some, but not all, aspects of inhibitory control. Individuals with ASD appear to have difficulty ignoring distracting visual information, but prepotent response inhibition and resistance to proactive interference are relatively intact. The current findings also provide support for a multitype model of inhibitory control.

  4. Biomechanical Properties of a Novel Biodegradable Magnesium-Based Interference Screw

    PubMed Central

    Ezechieli, Marco; Meyer, Hanna; Lucas, Arne; Helmecke, Patrick; Becher, Christoph; Calliess, Tilman; Windhagen, Henning; Ettinger, Max

    2016-01-01

    Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a standard implant (Milagro®; De Puy Mitek, Raynham, MA, USA) were used for graft fixation. Specimens were placed into a tensile loading fixation of a servohydraulic testing machine. Biomechanical analysis included pretensioning of the constructs at 20 N for 1 min following cyclic pretensioning of 20 cycles between 20 and 60 N. Biomechanical elongation was evaluated with cyclic loading of 1000 cycles between 50 and 200 N at 0.5 Hz. Maximum load to failure was 511.3±66.5 N for the Milagro® screw and 529.0±63.3 N for magnesium-based screw (ns, P=0.57). Elongations after preload, during cyclical loading and during failure load were not different between the groups (ns, P>0.05). Stiffness was 121.1±13.8 N/mm for the magnesium-based screw and 144.1±18.4 for the Milagro® screw (ns, P=0.32). MgYREZr alloy interference screws show comparable results in biomechanical testing to standard implants and may be an alternative for anterior cruciate reconstruction in the future. PMID:27433303

  5. Time and interference: Effects on working memory.

    PubMed

    Botto, Marta; Palladino, Paola

    2016-05-01

    This study tested predictions from the time-based resource-sharing (TBRS) model with a classical verbal working memory (WM) task, where target and non-target information interfere strongly with each other. Different predictions can be formulated according to the dominant perspectives (TBRS and interference hypothesis) on the role of inhibitory control in WM task performance. Here, we aimed to trace the activation of irrelevant information, examining priming effects in a lexical decision task immediately following WM recall. Results indicate the roles of both time and interference constraints in determining task performance. In particular, the role of time available seemed crucial at the highest WM loads (i.e., 3 and 4 memoranda). These were also associated with a higher activation of no-longer-relevant information but, in this case, independently from time available for processing. © 2015 The British Psychological Society.

  6. Advanced experimental techniques for transonic wind tunnels - Final lecture

    NASA Technical Reports Server (NTRS)

    Kilgore, Robert A.

    1987-01-01

    A philosophy of experimental techniques is presented, suggesting that in order to be successful, one should like what one does, have the right tools, stick to the job, avoid diversions, work hard, interact with people, be informed, keep it simple, be self sufficient, and strive for perfection. Sources of information, such as bibliographies, newsletters, technical reports, and technical contacts and meetings are recommended. It is pointed out that adaptive-wall test sections eliminate or reduce wall interference effects, and magnetic suspension and balance systems eliminate support-interference effects, while the problem of flow quality remains with all wind tunnels. It is predicted that in the future it will be possible to obtain wind tunnel results at the proper Reynolds number, and the effects of flow unsteadiness, wall interference, and support interference will be eliminated or greatly reduced.

  7. Effects of Sm addition on electromagnetic interference shielding property of Mg-Zn-Zr alloys

    NASA Astrophysics Data System (ADS)

    Yang, Chubin; Pan, Fusheng; Chen, Xianhua; Luo, Ning

    2017-06-01

    The electromagnetic interference (EMI) shielding of Sm-containing magnesium alloys in the 30-1500 MHz testing frequency range was investigated by coaxial cable method. The results demonstrated that Mg-3Zn alloys displayed the best electromagnetic shielding property. When 0.5 wt% of Zr was added for crystal grain refinement, the shielding effectiveness (SE) was apparently reduced. The addition of the rare earth element Sm in ZK magnesium alloys can improve the electromagnetic interference shielding of magnesium alloys. The main reason for the differences in electromagnetic interference shielding of magnesium alloys was the change in conductivity. The addition of Zr in Mg-Zn alloys can refine the grains and consequently improve the grain boundary area significantly. Therefore, the number of irregularly arranged atoms at the grain boundaries increased, decreasing the conductivity of magnesium alloys and leading to a decrease in the electromagnetic interference shielding. Following the Sm addition, the Mg-Zn-Sm phase was precipitated at the grain boundaries and in cores. The precipitation of Sm-containing rare earth phases could consume the solid-soluted Zn atoms within the Mg, resulting in an increase in electrical conductivity and electromagnetic interference shielding improvement.

  8. Electromagnetic Interference Assessment of CDMA and GSM Wireless Phones to Aircraft Navigation Radios

    NASA Technical Reports Server (NTRS)

    Ely, Jay J.; Nguyen, Truong X.; Koppen, Sandra V.; Salud, M. Theresa

    2002-01-01

    To address the concern for cellular phone electromagnetic interference (EMI) to aircraft radios, a radiated emission measurement process for CDMA (IS-95) and GSM (ETSI GSM 11.22) wireless handsets was developed. Spurious radiated emissions were efficiently characterized from devices tested in either a semi-anechoic or reverberation chamber, in terms of effective isotropic radiated power. Eight representative handsets (4 GSM, 4 CDMA) were commanded to operate while varying their radio transmitter parameters (power, modulation, etc.). This report provides a detailed description of the measurement process and resulting data, which may subsequently be used by others as a basis of consistent evaluation for cellular/PCS phones, Bluetooth, IEEE802.11b, IEEE802.11a, FRS/GMRS radios, and other portable transmitters. Aircraft interference path loss (IPL) and navigation radio interference threshold data from numerous reference documents, standards, and NASA partnerships were compiled. Using this data, a preliminary risk assessment is provided for CDMA and GSM wireless phone interference to aircraft localizer, Glideslope, VOR, and GPS radio receivers on typical transport airplanes. The report identifies where existing data for device emissions, IPL, and navigation radio interference thresholds needs to be extended for an accurate risk assessment for wireless transmitters in aircraft.

  9. Wireless Phone Threat Assessment and New Wireless Technology Concerns for Aircraft Navigation Radios

    NASA Technical Reports Server (NTRS)

    Ely, Jay J.; Nguyen, Truong X.; Koppen, Sandra V.; Beggs, John H.; Salud, Maria Theresa P.

    2003-01-01

    To address the concern for cellular phone electromagnetic interference to aircraft radios, a radiated emission measurement process was developed for two dominant digital standards of wireless handsets. Spurious radiated emissions were efficiently characterized from devices tested in either a semi-anechoic or reverberation chamber, in terms of effective radiated power. Eight representative handsets (four from each digital standard) were commanded to operate while varying their radio transmitter parameters (power, modulation, etc.). This report provides a detailed description of the measurement process and resulting data, which may subsequently be used by others as a basis of consistent evaluation of other portable transmitters using a variety of wireless transmission protocols. Aircraft interference path loss and navigation radio interference threshold data from numerous reference documents, standards, and NASA partnerships were compiled. Using these data, a preliminary risk assessment is provided for wireless phone interference to aircraft Localizer, Glideslope, Very High Frequency Omni directional Range, and Global Positioning Satellite radio receivers on typical transport airplanes. The report identifies where existing data for device emissions, interference path loss, and navigation radio interference thresholds need to be extended for an accurate risk assessment for wireless transmitters in aircraft.

  10. Associations of Adiposity and Aerobic Fitness with Executive Function and Math Performance in Danish Adolescents.

    PubMed

    Huang, Tao; Tarp, Jakob; Domazet, Sidsel Louise; Thorsen, Anne Kær; Froberg, Karsten; Andersen, Lars Bo; Bugge, Anna

    2015-10-01

    To examine the associations of adiposity and aerobic fitness with executive function and math performance in Danish adolescents. Cross-sectional analyses were conducted with data on 525 adolescents attending sixth and seventh grades from 14 schools in the 5 main regions of Denmark. A modified Eriksen flanker task was used to assess inhibitory control, a key aspect of executive function. Academic performance was assessed by a customized math test. Aerobic fitness was assessed by an intermittent shuttle-run test (Andersen test). Body mass index (BMI) was negatively associated with accuracy on incongruent trials during the flanker task (P = .005). A higher BMI was associated with a larger accuracy interference score (P = .01). Similarly, waist circumference (WC) was negatively associated with accuracy on incongruent trials (P = .008). A higher WC was associated with a larger reaction time (RT) interference score (P = .02) and accuracy interference score (P = .009). Higher aerobic fitness was associated with a faster RT on congruent trials (P = .009) and incongruent trials (P = .003). Higher aerobic fitness was associated with a smaller RT interference score (P = .04). Aerobic fitness was positively associated with math score (P < .001). BMI and WC were not associated with math score (P > .05). These results suggest that aerobic fitness is positively associated with both inhibitory control and math performance in adolescents. Adiposity is negatively associated with inhibitory control in adolescents. Adiposity is not associated with math performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Third-generation mobile phones (UMTS) do not interfere with permanent implanted pacemakers.

    PubMed

    Ismail, Mohamed M; Badreldin, Akmal M A; Heldwein, Matthias; Hekmat, Khosro

    2010-07-01

    Third-generation mobile phones, UMTS (Universal Mobile Telecommunication System), were recently introduced in Europe. The safety of these devices with regard to their interference with implanted pacemakers is as yet unknown and is the point of interest in this study. The study comprised 100 patients with permanent pacemaker implantation between November 2004 and June 2005. Two UMTS cellular phones (T-Mobile, Vodafone) were tested in the standby, dialing, and operating mode with 23 single-chamber and 77 dual-chamber pacemakers. Continuous surface electrocardiograms (ECGs), intracardiac electrograms, and marker channels were recorded when calls were made by a stationary phone to cellular phone. All pacemakers were tested under a "worst-case scenario," which includes a programming of the pacemaker to unipolar sensing and pacing modes and inducing of a maximum sensitivity setting during continuous pacing of the patient. Patients had pacemaker implantation between June 1990 and April 2005. The mean age was 68.4 +/- 15.1 years. Regardless of atrial and ventricular sensitivity settings, both UMTS mobile phones (Nokia 6650 and Motorola A835) did not show any interference with all tested pacemakers. In addition, both cellular phones did not interfere with the marker channels and the intracardiac ECGs of the pacemakers. Third-generation mobile phones are safe for patients with permanent pacemakers. This is due to the high-frequency band for this system (1,800-2,200 MHz) and the low power output between 0.01 W and 0.25 W.

  12. Polysomnography

    MedlinePlus

    ... Test Whether the test is at a sleep study center or at home, you prepare the same way. Unless directed to do so by your doctor, do not take any sleep medicine and do not drink alcohol or caffeinated beverages before the test. They can interfere with your ...

  13. The Medial Temporal Lobe and the Left Inferior Prefrontal Cortex Jointly Support Interference Resolution in Verbal Working Memory

    ERIC Educational Resources Information Center

    Oztekin, Ilke; Curtis, Clayton E.; McElree, Brian

    2009-01-01

    During working memory retrieval, proactive interference (PI) can be induced by semantic similarity and episodic familiarity. Here, we used fMRI to test hypotheses about the role of the left inferior frontal gyrus (LIFG) and the medial temporal lobe (MTL) regions in successful resolution of PI. Participants studied six-word lists and responded to a…

  14. The Loss Spiral of Work Pressure, Work-Home Interference and Exhaustion: Reciprocal Relations in a Three-Wave Study

    ERIC Educational Resources Information Center

    Demerouti, Evangelia; Bakker, Arnold B.; Bulters, Annemieke J.

    2004-01-01

    This study tested the "loss spiral" hypothesis of work-home interference (WHI). Accordingly, work pressure was expected to lead to WHI and exhaustion, and, vice versa, exhaustion was expected to result in more WHI and work pressure over time. Results of SEM-analyses using three waves of data obtained from 335 employees of an employment agency…

  15. Do Female and Male Employees in Iran Experience Similar Work-Family Interference, Job, and Life Satisfaction?

    ERIC Educational Resources Information Center

    Karimi, Leila

    2009-01-01

    This study aims at examining gender differences in the experience of work-family interference and perceived job-life satisfaction in a group of Iranian employees. The participants in the study consist of 387 Iranian male and female employees from a variety of organizations. The results of t tests and multiple regression analysis using EQS 6.1…

  16. Working Memory Capacity in a Go/No-Go Task: Age Differences in Interference, Processing Speed, and Attentional Control

    ERIC Educational Resources Information Center

    Rodríguez-Villagra, Odir Antonio; Göthe, Katrin; Oberauer, Klaus; Kliegl, Reinhold

    2013-01-01

    We tested the limits of working-memory capacity (WMC) of young adults, old adults, and children with a memory-updating task. The task consisted of mentally shifting spatial positions within a grid according to arrows, their color signaling either only go (control) or go/no-go conditions. The interference model (IM) of Oberauer and Kliegl (2006)…

  17. Negative Priming Effect after Inhibition of Weight/Number Interference in a Piaget-Like Task

    ERIC Educational Resources Information Center

    Schirlin, Olivier; Houde, Olivier

    2007-01-01

    Piagetian tasks have more to do with the child's ability to inhibit interference than they do with the ability to grasp their underlying logic. Here we used a chronometric paradigm with 11-year-olds, who succeed in Piaget's conservation-of-weight task, to test the role of cognitive inhibition in a priming version of this classical task. The…

  18. Family Interference with Work and Workplace Cognitive Failure: The Mitigating Role of Recovery Experiences

    ERIC Educational Resources Information Center

    Lapierre, Laurent M.; Hammer, Leslie B.; Truxillo, Donald M.; Murphy, Lauren A.

    2012-01-01

    The first goal of this study was to test whether family interference with work (FIW) is positively related to increased workplace cognitive failure (WCF), which is defined as errors made at work that indicate lapses in memory (e.g., failing to recall work procedures), attention (e.g., not fully listening to instruction), and motor function (e.g.,…

  19. Are Independent Probes Truly Independent?

    ERIC Educational Resources Information Center

    Camp, Gino; Pecher, Diane; Schmidt, Henk G.; Zeelenberg, Rene

    2009-01-01

    The independent cue technique has been developed to test traditional interference theories against inhibition theories of forgetting. In the present study, the authors tested the critical criterion for the independence of independent cues: Studied cues not presented during test (and unrelated to test cues) should not contribute to the retrieval…

  20. Wall interference correction improvements for the ONERA main wind tunnels

    NASA Technical Reports Server (NTRS)

    Vaucheret, X.

    1982-01-01

    This paper describes improved methods of calculating wall interference corrections for the ONERA large windtunnels. The mathematical description of the model and its sting support have become more sophisticated. An increasing number of singularities is used until an agreement between theoretical and experimental signatures of the model and sting on the walls of the closed test section is obtained. The singularity decentering effects are calculated when the model reaches large angles of attack. The porosity factor cartography on the perforated walls deduced from the measured signatures now replaces the reference tests previously carried out in larger tunnels. The porosity factors obtained from the blockage terms (signatures at zero lift) and from the lift terms are in good agreement. In each case (model + sting + test section), wall corrections are now determined, before the tests, as a function of the fundamental parameters M, CS, CZ. During the windtunnel tests, the corrections are quickly computed from these functions.

  1. Domain-Specific Interference Tests on Navigational Working Memory in Military Pilots.

    PubMed

    Verde, Paola; Boccia, Maddalena; Colangeli, Stefano; Barbetti, Sonia; Nori, Raffaella; Ferlazzo, Fabio; Piccolo, Francesco; Vitalone, Roberto; Lucertini, Elena; Piccardi, Laura

    2016-06-01

    Human navigation is a very complex ability that encompasses all four stages of human information processing (sensory input, perception/cognition, selection, and execution of an action), involving both cognitive and physical requirements. During flight, the pilot uses all of these stages and one of the most critical aspect is interference. In fact, spatial tasks competing for the same cognitive resource cause greater distraction from a concurrent task than another task that uses different resource modalities. Here we compared and contrasted the performance of pilots and nonpilots of both genders performing increasingly complex navigational memory tasks while exposed to various forms of interference. We investigated the effects of four different sources of interference: motor, spatial motor, verbal, and spatial environment, focusing on gender differences. We found that flight experts perform better than controls (Pilots: 6.50 ± 1.29; Nonpilots: 5.45 ± 1.41). Furthermore, in the general population, navigational working memory is compromised only by spatial environmental interference (Nonpilots: 4.52 ± 1.50); female nonpilots were less able than male nonpilots. Also, the flight expert group showed the same interference, even if reduced (Pilots: 5.24 ± 0.92); moreover, we highlighted a complete absence of gender-related effects. Spatial environmental interference is the only interference producing a decrease in performance. Nevertheless, pilots are less affected than the general population. This is probably a consequence of the need to commit substantial cognitive resources to process spatial information during flight.

  2. Space shuttle launch vehicle (13 P-OTS) strut support interference effects study in the Rockwell International 7- by 7-foot trisonic wind tunnel (IA68)

    NASA Technical Reports Server (NTRS)

    Rogge, R. L.

    1974-01-01

    Strut support interference investigations were conducted on an 0.004-(-) scale representation of the space shuttle launch vehicle in order to determine transonic and supersonic model support interference effects for use in a future exhaust plume effects study. Strut configurations were also tested. Orbiter, external tank, and solid rocket booster pressures were recorded at Mach numbers 0.9, 1.2, 1.5, and 2.0. Angle of attack and angle of sideslip were varied between plus or minus 4 degrees in 2 degree increments. Parametric variations consisted only of the strut configurations.

  3. Speech-Message Extraction from Interference Introduced by External Distributed Sources

    NASA Astrophysics Data System (ADS)

    Kanakov, V. A.; Mironov, N. A.

    2017-08-01

    The problem of this study involves the extraction of a speech signal originating from a certain spatial point and calculation of the intelligibility of the extracted voice message. It is solved by the method of decreasing the influence of interference from the speech-message sources on the extracted signal. This method is based on introducing the time delays, which depend on the spatial coordinates, to the recording channels. Audio records of the voices of eight different people were used as test objects during the studies. It is proved that an increase in the number of microphones improves intelligibility of the speech message which is extracted from interference.

  4. Cognitive Load Selectively Interferes with Utilitarian Moral Judgment

    PubMed Central

    Greene, Joshua D.; Morelli, Sylvia A.; Lowenberg, Kelly; Nystrom, Leigh E.; Cohen, Jonathan D.

    2008-01-01

    Traditional theories of moral development emphasize the role of controlled cognition in mature moral judgment, while a more recent trend emphasizes intuitive and emotional processes. Here we test a dual-process theory synthesizing these perspectives. More specifically, our theory associates utilitarian moral judgment (approving of harmful actions that maximize good consequences) with controlled cognitive processes and associates non-utilitarian moral judgment with automatic emotional responses. Consistent with this theory, we find that a cognitive load manipulation selectively interferes with utilitarian judgment. This interference effect provides direct evidence for the influence of controlled cognitive processes in moral judgment, and utilitarian moral judgment more specifically. PMID:18158145

  5. KSC-05PD-1072

    NASA Technical Reports Server (NTRS)

    2005-01-01

    KENNEDY SPACE CENTER, FLA. In the Payload Hazardous Servicing Facility, technicians inspect the solar panels for the Mars Reconnaissance Orbiter (MRO) during an electromagnetic interference verification test. If no interference is found during the test, the Shallow Radar Antenna (SHARAD) will be installed on the spacecraft. The spacecraft is undergoing multiple mechanical assembly operations and electrical tests to verify its readiness for launch. The MRO was built by Lockheed Martin for NASAs Jet Propulsion Laboratory in California. It is the next major step in Mars exploration and scheduled for launch from Launch Complex 41 at Cape Canaveral Air Force Station in a window opening Aug. 10. The MRO is an important next step in fulfilling NASAs vision of space exploration and ultimately sending human explorers to Mars and beyond.

  6. How Reliable Are ATP Bioluminescence Meters in Assessing Decontamination of Environmental Surfaces in Healthcare Settings?

    PubMed Central

    Omidbakhsh, Navid; Ahmadpour, Faraz; Kenny, Nicole

    2014-01-01

    Background Meters based on adenosine triphosphate (ATP) bioluminescence measurements in relative light units (RLU) are often used to rapidly assess the level of cleanliness of environmental surfaces in healthcare and other settings. Can such ATP measurements be adversely affected by factors such as soil and cleaner-disinfectant chemistry? Objective This study tested a number of leading ATP meters for their sensitivity, linearity of the measurements, correlation of the readings to the actual microbial contamination, and the potential disinfectant chemicals’ interference in their readings. Methods First, solutions of pure ATP in various concentrations were used to construct a standard curve and determine linearity and sensitivity. Serial dilutions of a broth culture of Staphylococcus aureus, as a representative nosocomial pathogen, were then used to determine if a given meter’s ATP readings correlated with the actual CFUs. Next, various types of disinfectant chemistries were tested for their potential to interfere with the standard ATP readings. Results All four ATP meters tested herein demonstrated acceptable linearity and repeatability in their readings. However, there were significant differences in their sensitivity to detect the levels of viable microorganisms on experimentally contaminated surfaces. Further, most disinfectant chemistries tested here quenched the ATP readings variably in different ATP meters evaluated. Conclusions Apart from their limited sensitivity in detecting low levels of microbial contamination, the ATP meters tested were also prone to interference by different disinfectant chemistries. PMID:24940751

  7. Highlights of experience with a flexible walled test section in the NASA Langley 0.3-meter transonic cryogenic tunnel

    NASA Technical Reports Server (NTRS)

    Wolf, Stephen W. D.; Ray, Edward J.

    1988-01-01

    The unique combination of adaptive wall technology with a contonuous flow cryogenic wind tunnel is described. This powerful combination allows wind tunnel users to carry out 2-D tests at flight Reynolds numbers with wall interference essentially eliminated. Validation testing was conducted to support this claim using well tested symmetrical and cambered airfoils at transonic speeds and high Reynolds numbers. The test section hardware has four solid walls, with the floor and ceiling flexible. The method of adapting/shaping the floor and ceiling to eliminate top and bottom wall interference at its source is outlined. Data comparisons for different size models tested and others in several sophisticated 2-D wind tunnels are made. In addition, the effects of Reynolds number, testing at high lift with associated large flexible wall movements, the uniqueness of the adapted wall shapes, and the effects of sidewall boundary layer control are examined. The 0.3-m TCT is now the most advanced 2-D research facility anywhere.

  8. Correaltion of full-scale drag predictions with flight measurements on the C-141A aircraft. Phase 2: Wind tunnel test, analysis, and prediction techniques. Volume 1: Drag predictions, wind tunnel data analysis and correlation

    NASA Technical Reports Server (NTRS)

    Macwilkinson, D. G.; Blackerby, W. T.; Paterson, J. H.

    1974-01-01

    The degree of cruise drag correlation on the C-141A aircraft is determined between predictions based on wind tunnel test data, and flight test results. An analysis of wind tunnel tests on a 0.0275 scale model at Reynolds number up to 3.05 x 1 million/MAC is reported. Model support interference corrections are evaluated through a series of tests, and fully corrected model data are analyzed to provide details on model component interference factors. It is shown that predicted minimum profile drag for the complete configuration agrees within 0.75% of flight test data, using a wind tunnel extrapolation method based on flat plate skin friction and component shape factors. An alternative method of extrapolation, based on computed profile drag from a subsonic viscous theory, results in a prediction four percent lower than flight test data.

  9. Technical evaluation of the novel preanalytical module on instrumentation laboratory ACL TOP: advancing automation in hemostasis testing.

    PubMed

    Lippi, Giuseppe; Ippolito, Luigi; Favaloro, Emmanuel J

    2013-10-01

    Automation in hemostasis testing is entering an exciting and unprecedented phase. This study was planned to assess the performance of the new preanalytical module on the hemostasis testing system Instrumentation Laboratory ACL TOP. The evaluation included interference studies to define reliable thresholds for rejecting samples with significant concentrations of interfering substances; within-run imprecision studies of plasma indices on four different interference degrees for each index; comparison studies with reference measures of hemolysis index, bilirubin, and triglycerides on clinical chemistry analyzers; and calculation of turnaround time with and without automatic performance of preanalytical check. The upper limits for sample rejection according to our interference studies were 3.6 g/L for hemoglobin, 13.6 mg/dL for bilirubin, and 1454 mg/dL for triglycerides. We found optimal precision for all indices (0.6% to 3.1% at clinically relevant thresholds) and highly significant correlations with reference measures on clinical chemistry analyzers (from 0.985 to 0.998). The limited increase of turnaround time (i.e., +3% and +5% with or without cap-piercing), coupled with no adjunctive costs over performance of normal coagulation assays, contribute to make the automatic check of plasma indices on ACL TOP a reliable and practical approach for improving testing quality and safeguarding patient safety.

  10. Study on the electromagnetic radiation characteristics of discharging excimer laser system

    NASA Astrophysics Data System (ADS)

    Zhao, Duliang; Liang, Xu; Fang, Xiaodong; Wang, Qingsheng

    2016-10-01

    Excimer laser in condition of high voltage, large current and fast discharge will produce strong electromagnetic pulse radiation and electromagnetic interference on the around electrical equipment. The research on characteristics and distribution of excimer laser electromagnetic radiation could provide important basis for electromagnetic shielding and suppressing electromagnetic interference, and further improving the electromagnetic compatibility of system. Firstly, electromagnetic radiation source is analyzed according to the working principle of excimer laser. The key test points of the electromagnetic radiation, hydrogen thyratron, main discharge circuit and laser outlet, are determined by the mechanical structure and the theory of electromagnetic radiation. Secondly, characteristics of electromagnetic field were tested using a near field probe on the key positions of the vertical direction at 20, 50, and 80 cm, respectively. The main radiation frequencies and the radiation field characteristics in the near field are obtained. The experimental results show that the main radiation frequencies distribute in 47, 65, and 130 MHz for electric field and the main radiation frequencies distribute in 34, 100, and 165 MHz for magnetic field. The intensity of electromagnetic field decreases rapidly with the increase of test distance. The higher the frequency increases, the faster the amplitude attenuate. Finally, several electromagnetic interference suppression measurement methods are proposed from the perspective of electromagnetic compatibility according to the test results.

  11. Low risk of electromagnetic interference between smartphones and contemporary implantable cardioverter defibrillators.

    PubMed

    Burri, Haran; Mondouagne Engkolo, Louis Paulin; Dayal, Nicolas; Etemadi, Abdul; Makhlouf, Anne-Marie; Stettler, Carine; Trentaz, Florence

    2016-05-01

    Manufacturers of implantable cardioverter defibrillators (ICDs) recommend that cell phones be maintained at a distance of ∼15 cm from the implanted device in order to avoid risk of dysfunction due to electromagnetic interference (EMI). Data relating to this issue are outdated and do not reflect modern technology. Our aim was to evaluate whether EMI is still an issue with contemporary ICDs and smartphones. Consecutive patients implanted with a wireless-enabled ICD were tested for potential interference with two models of recent 4G smartphones in conditions intended to maximize risk of EMI. A magnet effect (due to the phone speakers) was tested by placing the smartphones in the standby mode directly over the ICD generator. The presence of EMI artefacts on the real-time electrograms was evaluated by placing the smartphones in the standby, dialling, and operating modes directly over the generator casing and over the parasternal region in the vicinity of the ventricular lead. A total of 63 patients equipped with 29 different models of single, dual, or biventricular ICDs from five major manufacturers were included. None of the patients showed any evidence of interference with the smartphones during any of the 882 tests. The risk of EMI between modern smartphones and contemporary ICDs is low. This is probably due to the filters incorporated in the ICDs and low emission by the phones, as well as the small size of the magnets in the smartphones tested. NCT02330900 (http://www.clinicaltrials.gov). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  12. Electromagnetic interference of GSM mobile phones with the implantable deep brain stimulator, ITREL-III

    PubMed Central

    Kainz, Wolfgang; Alesch, François; Chan, Dulciana Dias

    2003-01-01

    Background The purpose was to investigate mobile phone interference with implantable deep brain stimulators by means of 10 different 900 Mega Hertz (MHz) and 10 different 1800 MHz GSM (Global System for Mobile Communications) mobile phones. Methods All tests were performed in vitro using a phantom especially developed for testing with deep brain stimulators. The phantom was filled with liquid phantom materials simulating brain and muscle tissue. All examinations were carried out inside an anechoic chamber on two implants of the same type of deep brain stimulator: ITREL-III from Medtronic Inc., USA. Results Despite a maximum transmitted peak power of mobile phones of 1 Watt (W) at 1800 MHz and 2 W at 900 MHz respectively, no influence on the ITREL-III was found. Neither the shape of the pulse form changed nor did single pulses fail. Tests with increased transmitted power using CW signals and broadband dipoles have shown that inhibition of the ITREL-III occurs at frequency dependent power levels which are below the emissions of GSM mobile phones. The ITREL-III is essentially more sensitive at 1800 MHz than at 900 MHz. Particularly the frequency range around 1500 MHz shows a very low interference threshold. Conclusion These investigations do not indicate a direct risk for ITREL-III patients using the tested GSM phones. Based on the interference levels found with CW signals, which are below the mobile phone emissions, we recommend similar precautions as for patients with cardiac pacemakers: 1. The phone should be used at the ear at the opposite side of the implant and 2. The patient should avoid carrying the phone close to the implant. PMID:12773204

  13. Some ideas and opportunities concerning three-dimensional wind-tunnel wall corrections

    NASA Technical Reports Server (NTRS)

    Rubbert, P. E.

    1982-01-01

    Opportunities for improving the accuracy and reliability of wall corrections in conventional ventilated test sections are presented. The approach encompasses state-of-the-art technology in transonic computational methods combined with the measurement of tunnel-wall pressures. The objective is to arrive at correction procedures of known, verifiable accuracy that are practical within a production testing environment. It is concluded that: accurate and reliable correction procedures can be developed for cruise-type aerodynamic testing for any wall configuration; passive walls can be optimized for minimal interference for cruise-type aerodynamic testing (tailored slots, variable open area ratio, etc.); monitoring and assessment of noncorrectable interference (buoyancy and curvature in a transonic stream) can be an integral part of a correction procedure; and reasonably good correction procedures can probably be developd for complex flows involving extensive separation and other unpredictable phenomena.

  14. 47 CFR 80.101 - Radiotelephone testing procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... five minutes. (b) Testing of transmitters must be confined to single frequency channels on working... operator must not interfere with transmissions in progress. (2) The testing station's call sign, followed by the word “test”, must be announced on the radio-channel being used for the test. (3) If any...

  15. 47 CFR 80.101 - Radiotelephone testing procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... five minutes. (b) Testing of transmitters must be confined to single frequency channels on working... operator must not interfere with transmissions in progress. (2) The testing station's call sign, followed by the word “test”, must be announced on the radio-channel being used for the test. (3) If any...

  16. Escaping the recent past: Which stimulus dimensions influence proactive interference?

    PubMed Central

    Craig, Kimberly S.; Berman, Marc G.; Jonides, John; Lustig, Cindy

    2013-01-01

    Proactive interference occurs when information from the past disrupts current processing and is a major source of confusion and errors in short-term memory (Wickens, Born & Allen, 1963). The present investigation examines potential boundary conditions for interference, testing the hypothesis that potential competitors must be similar along task-relevant dimensions to influence proactive interference effects. We manipulated both the type of task being completed (Experiments 1, 2 and 3) and dimensions of similarity irrelevant to the current task (Experiments 4 and 5) to determine how the recent presentation of a probe item would affect the speed with which participants could reject that item. Experiments 1, 2 and 3 contrasted short-term memory judgments, which require temporal information, with semantic and perceptual judgments, for which temporal information is irrelevant. In Experiments 4 and 5, task-irrelevant information (perceptual similarity) was manipulated within the recent probes task. We found that interference from past items affected short-term memory (STM) task performance but did not affect performance in semantic or perceptual judgment tasks. Conversely, similarity along a nominally-irrelevant perceptual dimension did not affect the magnitude of interference in STM tasks. Results are consistent with the view that items in STM are represented by noisy codes consisting of multiple dimensions, and that interference occurs when items are similar to each other and thus compete along the dimensions relevant to target selection. PMID:23297049

  17. Escaping the recent past: which stimulus dimensions influence proactive interference?

    PubMed

    Craig, Kimberly S; Berman, Marc G; Jonides, John; Lustig, Cindy

    2013-07-01

    Proactive interference occurs when information from the past disrupts current processing and is a major source of confusion and errors in short-term memory (STM; Wickens, Born, & Allen, Journal of Verbal Learning and Verbal Behavior, 2:440-445, 1963). The present investigation examines potential boundary conditions for interference, testing the hypothesis that potential competitors must be similar along task-relevant dimensions to influence proactive interference effects. We manipulated both the type of task being completed (Experiments 1, 2, and 3) and dimensions of similarity irrelevant to the current task (Experiments 4 and 5) to determine how the recent presentation of a probe item would affect the speed with which participants could reject that item. Experiments 1, 2, and 3 contrasted STM judgments, which require temporal information, with semantic and perceptual judgments, for which temporal information is irrelevant. In Experiments 4 and 5, task-irrelevant information (perceptual similarity) was manipulated within the recent probes task. We found that interference from past items affected STM task performance but did not affect performance in semantic or perceptual judgment tasks. Conversely, similarity along a nominally irrelevant perceptual dimension did not affect the magnitude of interference in STM tasks. Results are consistent with the view that items in STM are represented by noisy codes consisting of multiple dimensions and that interference occurs when items are similar to each other and, thus, compete along the dimensions relevant to target selection.

  18. Change perception and change interference within and across feature dimensions.

    PubMed

    Pilling, Michael; Barrett, Doug J K

    2018-06-04

    The ability to perceive a change in a visual object is reduced when that change is presented in competition with other changes which are task-irrelevant. We performed two experiments which investigate the basis of this change interference effect. We tested whether change interference occurs as a consequence of some form of attentional capture, or whether the interference occurs at a stage prior to attentional selection of the task-relevant change. A modified probe-detection task was used to explore this issue. Observers were required to report the presence/absence of a specified change-type (colour, shape) in the probe, in a context in which - on certain trials - irrelevant changes occur in non-probe items. There were two key variables in these experiments: the attentional state of the observer, and the dimensional congruence of changes in the probe and non-probe items. Change interference was strongest when the irrelevant changes were the same as those on the report dimension. However the interference pattern persisted even when observers did not know the report dimension at the time the changes occurred. These results seem to rule out attention as a factor. Our results fit best with an interpretation in which change interference produces feature-specific sensory noise which degrades the signal quality of the target change. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Performance Comparison of Wireless Sensor Network Standard Protocols in an Aerospace Environment: ISA100.11a and ZigBee

    NASA Technical Reports Server (NTRS)

    Wagner, Raymond S.; Barton, Richard J.

    2011-01-01

    Wireless Sensor Networks (WSNs) can provide a substantial benefit in spacecraft systems, reducing launch weight and providing unprecedented flexibility by allowing instrumentation capabilities to grow and change over time. Achieving data transport reliability on par with that of wired systems, however, can prove extremely challenging in practice. Fortunately, much progress has been made in developing standard WSN radio protocols for applications from non-critical home automation to mission-critical industrial process control. The relative performances of candidate protocols must be compared in representative aerospace environments, however, to determine their suitability for spaceflight applications. In this paper, we will present the results of a rigorous laboratory analysis of the performance of two standards-based, low power, low data rate WSN protocols: ZigBee Pro and ISA100.11a. Both are based on IEEE 802.15.4 and augment that standard's specifications to build complete, multi-hop networking stacks. ZigBee Pro targets primarily the home and office automation markets, providing an ad-hoc protocol that is computationally lightweight and easy to implement in inexpensive system-on-a-chip components. As a result of this simplicity, however, ZigBee Pro can be susceptible to radio frequency (RF) interference. ISA100.11a, on the other hand, targets the industrial process control market, providing a robust, centrally-managed protocol capable of tolerating a significant amount of RF interference. To achieve these gains, a coordinated channel hopping mechanism is employed, which entails a greater computational complexity than ZigBee and requires more sophisticated and costly hardware. To guide future aerospace deployments, we must understand how well these standards relatively perform in analog environments under expected operating conditions. Specifically, we are interested in evaluating goodput -- application level throughput -- in a representative crewed environment in the presence of varying levels of 802.11g Wi-Fi traffic. To do so, we use the NASA Johnson Space Center Wireless Habitat Testbed (WHT), a metallic, habitation-sized module designed for co-existence testing of wireless systems. In its quiescent state, the sealed WHT provides an RF-quiet environment to which we can selectively add interfering systems; it also provides a realistic level of multi-path self-interference for systems under investigation. In our test, we deploy two representative five node networks, configured in a star topology with all nodes reporting directly to a WSN gateway. Each ZigBee network WSN node is built using a Texas Instruments (TI) CC2530 system-on-a-chip radio running TI's ZigBee Pro Z-stack. Each ISA100.11a network node is built using a Nivis VersaNode 210 system-on-a-chip radio. In both cases, radios interface with TI MSP430-F5438 microcontroller implementing a common test application. Interference is provided by a D-link 802.11g Wi-Fi router transporting traffic generated using the Iperf network testing tool. For the single-channel ZigBee network, effects of both direct and indirect Wi-Fi interference are evaluated. For the channel-hopping ISA100.11a network, effects of interference from multiple Wi-Fi routers configured in non-overlapping 802.11g channels are evaluated. Our results show that, in general, the more lightweight ZigBee network performs well at low interference levels, but performance degrades as interference increases. Conversely, the more complex and costly ISA100.11a network continues to perform well as Wi-Fi interference levels increase.

  20. Agreement between clinical and laboratory methods assessing tonic and cross-link components of accommodation and vergence.

    PubMed

    Neveu, Pascaline; Priot, Anne-Emmanuelle; Philippe, Matthieu; Fuchs, Philippe; Roumes, Corinne

    2015-09-01

    Several tests are available to optometrists for investigating accommodation and vergence. This study sought to investigate the agreement between clinical and laboratory methods and to clarify which components are actually measured when tonic and cross-link of accommodation and vergence are assessed. Tonic vergence, tonic accommodation, accommodative vergence (AC/A) and vergence accommodation (CA/C) were measured using several tests. Clinical tests were compared to the laboratory assessment, the latter being regarded as an absolute reference. The repeatability of each test and the degree of agreement between the tests were quantified using Bland-Altman analysis. The values obtained for each test were found to be stable across repetitions; however, in most cases, significant differences were observed between tests supposed to measure the same oculomotor component. Tonic and cross-link components cannot be easily assessed because proximal and instrumental responses interfere with the assessment. Other components interfere with oculomotor assessment. Specifically, accommodative divergence interferes with tonic vergence estimation and the type of accommodation considered in the AC/A ratio affects its magnitude. Results on clinical tonic accommodation and clinical CA/C show that further investigation is needed to clarify the limitations associated with the use of difference of Gaussian as visual targets to open the accommodative loop. Although different optometric tests of accommodation and vergence rely on the same basic principles, the results of this study indicate that clinical and laboratory methods actually involve distinct components. These differences, which are induced by methodological choices, must be taken into account, when comparing studies or when selecting a test to investigate a particular oculomotor component. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  1. Encoding and Retrieval Interference in Sentence Comprehension: Evidence from Agreement

    PubMed Central

    Villata, Sandra; Tabor, Whitney; Franck, Julie

    2018-01-01

    Long-distance verb-argument dependencies generally require the integration of a fronted argument when the verb is encountered for sentence interpretation. Under a parsing model that handles long-distance dependencies through a cue-based retrieval mechanism, retrieval is hampered when retrieval cues also resonate with non-target elements (retrieval interference). However, similarity-based interference may also stem from interference arising during the encoding of elements in memory (encoding interference), an effect that is not directly accountable for by a cue-based retrieval mechanism. Although encoding and retrieval interference are clearly distinct at the theoretical level, it is difficult to disentangle the two on empirical grounds, since encoding interference may also manifest at the retrieval region. We report two self-paced reading experiments aimed at teasing apart the role of each component in gender and number subject-verb agreement in Italian and English object relative clauses. In Italian, the verb does not agree in gender with the subject, thus providing no cue for retrieval. In English, although present tense verbs agree in number with the subject, past tense verbs do not, allowing us to test the role of number as a retrieval cue within the same language. Results from both experiments converge, showing similarity-based interference at encoding, and some evidence for an effect at retrieval. After having pointed out the non-negligible role of encoding in sentence comprehension, and noting that Lewis and Vasishth’s (2005) ACT-R model of sentence processing, the most fully developed cue-based retrieval approach to sentence processing does not predict encoding effects, we propose an augmentation of this model that predicts these effects. We then also propose a self-organizing sentence processing model (SOSP), which has the advantage of accounting for retrieval and encoding interference with a single mechanism. PMID:29403414

  2. Auditory and motor imagery modulate learning in music performance

    PubMed Central

    Brown, Rachel M.; Palmer, Caroline

    2013-01-01

    Skilled performers such as athletes or musicians can improve their performance by imagining the actions or sensory outcomes associated with their skill. Performers vary widely in their auditory and motor imagery abilities, and these individual differences influence sensorimotor learning. It is unknown whether imagery abilities influence both memory encoding and retrieval. We examined how auditory and motor imagery abilities influence musicians' encoding (during Learning, as they practiced novel melodies), and retrieval (during Recall of those melodies). Pianists learned melodies by listening without performing (auditory learning) or performing without sound (motor learning); following Learning, pianists performed the melodies from memory with auditory feedback (Recall). During either Learning (Experiment 1) or Recall (Experiment 2), pianists experienced either auditory interference, motor interference, or no interference. Pitch accuracy (percentage of correct pitches produced) and temporal regularity (variability of quarter-note interonset intervals) were measured at Recall. Independent tests measured auditory and motor imagery skills. Pianists' pitch accuracy was higher following auditory learning than following motor learning and lower in motor interference conditions (Experiments 1 and 2). Both auditory and motor imagery skills improved pitch accuracy overall. Auditory imagery skills modulated pitch accuracy encoding (Experiment 1): Higher auditory imagery skill corresponded to higher pitch accuracy following auditory learning with auditory or motor interference, and following motor learning with motor or no interference. These findings suggest that auditory imagery abilities decrease vulnerability to interference and compensate for missing auditory feedback at encoding. Auditory imagery skills also influenced temporal regularity at retrieval (Experiment 2): Higher auditory imagery skill predicted greater temporal regularity during Recall in the presence of auditory interference. Motor imagery aided pitch accuracy overall when interference conditions were manipulated at encoding (Experiment 1) but not at retrieval (Experiment 2). Thus, skilled performers' imagery abilities had distinct influences on encoding and retrieval of musical sequences. PMID:23847495

  3. Action Anticipation and Interference: A Test of Prospective Gaze

    PubMed Central

    Cannon, Erin N.; Woodward, Amanda L.

    2013-01-01

    In the current study we investigate the proposal that one aspect of social perception, action anticipation, involves the recruitment of representations for self-produced action. An eye tracking paradigm was implemented to measure prospective gaze to a goal while performing either a motor or working memory task. Results indicate an effect of the motor task, suggesting the interference of a shared motor and action perception representation. PMID:25285317

  4. Facilitation and Interference in Identification of Pictures and Words

    DTIC Science & Technology

    1994-10-05

    semantic activation and episodic memory encoding. Journal of Verbal Learning and Verbal Behavior, 22, 88-104. Becker, C. A. (1979). Semantic context...set of items, such as pictures of common objects or known words, which have representations in semantic memory . To test this, we compared the...activation model in particular because nonwords have no memorial representation in semantic memory and thus cannot interfere with ore another. 2. Long-term

  5. Retrieval Practice Fails to Insulate Episodic Memories against Interference after Stroke.

    PubMed

    Pastötter, Bernhard; Eberle, Hanna; Aue, Ingo; Bäuml, Karl-Heinz T

    2017-01-01

    Recent work in cognitive psychology showed that retrieval practice of previously studied information can insulate this information against retroactive interference from subsequently studied other information in healthy individuals. The present study examined whether this beneficial effect of interference reduction is also present in patients with stroke. Twenty-two patients with stroke, 4.6 months post injury on average, and 22 healthy controls participated in the experiment. In each of two experimental sessions, participants first studied a list of items (list 1) and then underwent a practice phase in which the list 1 items were either restudied or retrieval practiced. Participants then either studied a second list of items (list 2) or fulfilled an unrelated distractor task. Recall of the two lists' items was assessed in a final criterion test. Results showed that, in healthy controls, additional study of list 2 items impaired final recall of list 1 items in the restudy condition but not in the retrieval practice condition. In contrast, in patients with stroke, list 2 learning impaired final list 1 recall in both conditions. The results indicate that retrieval practice insulated the tested information against retroactive interference in healthy controls, but failed to do so in patients with stroke. Possible implications of the findings for the understanding of long-term memory impairment after stroke are discussed.

  6. Developmental Differences in Holistic Interference of Facial Part Recognition

    PubMed Central

    Nakabayashi, Kazuyo; Liu, Chang Hong

    2013-01-01

    Research has shown that adults’ recognition of a facial part can be disrupted if the part is learnt without a face context but tested in a whole face. This has been interpreted as the holistic interference effect. The present study investigated whether children of 6- and 9–10-year-olds would show a similar effect. Participants were asked to judge whether a probe part was the same as or different from a test part whereby the part was presented either in isolation or in a whole face. The results showed that while all the groups were susceptible to a holistic interference, the youngest group was most severely affected. Contrary to the view that piecemeal processing precedes holistic processing in the cognitive development, our findings demonstrate that holistic processing is already present at 6 years of age. It is the ability to inhibit the influence of holistic information on piecemeal processing that seems to require a longer period of development into at an older and adult age. PMID:24204847

  7. Quantitative anal sphincter electromyography in primiparous women with anal incontinence

    PubMed Central

    Gregory, W. Thomas; Lou, Jau-Shin; Simmons, Kimberly; Clark, Amanda L.

    2010-01-01

    OBJECTIVE The purpose of this study was to determine whether evidence of denervation/reinnervation of the external anal sphincter is associated with anal incontinence symptoms immediately after delivery. STUDY DESIGN After a first vaginal delivery, 42 women completed an anal incontinence questionnaire. They also underwent concentric needle electromyography of the external anal sphincter. For each subject, motor unit action potential and interference pattern parameters were determined. RESULTS For the motor unit action potential, no difference was observed between patients with and without anal incontinence symptoms (t-test). For the interference pattern, the amplitude/turn was greater in subjects with fecal urgency (318 ± 48 [SD] μV) and fecal incontinence (332 ± 48 μV), compared with those without fecal urgency (282 ± 38 μV) and fecal incontinence (286 ± 41 μV; P = .02, t-test). CONCLUSION In this group of postpartum women with mild anal incontinence symptoms, interference pattern analysis shows evidence of denervation and subsequent reinnervation. PMID:18455531

  8. Ultrawideband Electromagnetic Interference to Aircraft Radios

    NASA Technical Reports Server (NTRS)

    Ely, Jay J.; Fuller, Gerald L.; Shaver, Timothy W.

    2002-01-01

    A very recent FCC Final Rule now permits marketing and operation of new products that incorporate Ultrawideband (UWB) technology into handheld devices. Wireless product developers are working to rapidly bring this versatile, powerful and expectedly inexpensive technology into numerous consumer wireless devices. Past studies addressing the potential for passenger-carried portable electronic devices (PEDs) to interfere with aircraft electronic systems suggest that UWB transmitters may pose a significant threat to aircraft communication and navigation radio receivers. NASA, United Airlines and Eagles Wings Incorporated have performed preliminary testing that clearly shows the potential for handheld UWB transmitters to cause cockpit failure indications for the air traffic control radio beacon system (ATCRBS), blanking of aircraft on the traffic alert and collision avoidance system (TCAS) displays, and cause erratic motion and failure of instrument landing system (ILS) localizer and glideslope pointers on the pilot horizontal situation and attitude director displays. This paper provides details of the preliminary testing and recommends further assessment of aircraft systems for susceptibility to UWB electromagnetic interference.

  9. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Test Report, Electromagnetic Interference (EMI)/Electromagnetic Radiation(EMR) and Electromagnetic Capability (EMC) for the EOS/AMSU-A1

    NASA Technical Reports Server (NTRS)

    Paliwoda, L.

    1998-01-01

    This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Earth Observing System (EOS) Project, assembly part number 1356008-1, serial number 202, Electromagnetic Interference (EMI) and Electromagnetic Susceptibility (EMC) qualification test. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/8B, dated 10 September 1998. Aerojet intends that the presentation and submittal of this document, prepared in accordance with the objectives established by the aforementioned Test Plan/Procedure, document number AE-26151/8B, will satisfy the data requirement with respect to the AMSU-A/EOS instrument operational compliance of the EMI/EMC test requirement. Test for the AMSU-A/EOS instrument have been completed and all the requirements per General Interface Requirement Document (GIRD), GSFC 422-11-12-01, for EOS Common Spacecraft/Instruments, paragraph 10.11, were met with the exceptions of the test methods CE03, RE01, and RE02, as described in this document.

  10. AMPA experimental communications systems

    NASA Technical Reports Server (NTRS)

    Beckerman, D.; Fass, S.; Keon, T.; Sielman, P.

    1982-01-01

    The program was conducted to demonstrate the satellite communication advantages of Adaptive Phased Array Technology. A laboratory based experiment was designed and implemented to demonstrate a low earth orbit satellite communications system. Using a 32 element, L-band phased array augmented with 4 sets of weights (2 for reception and 2 for transmission) a high speed digital processing system and operating against multiple user terminals and interferers, the AMPA system demonstrated: communications with austere user terminals, frequency reuse, communications in the face of interference, and geolocation. The program and experiment objectives are described, the system hardware and software/firmware are defined, and the test performed and the resultant test data are presented.

  11. Does Temporal Integration of Face Parts Reflect Holistic Processing?

    PubMed Central

    Cheung, Olivia S.; Richler, Jennifer J.; Phillips, W. Stewart; Gauthier, Isabel

    2011-01-01

    We examined whether temporal integration of face parts reflects holistic processing or response interference. Participants learned to name two faces “Fred” and two “Bob”. At test, top and bottom halves of different faces formed composites and were presented briefly separated in time. Replicating prior findings (Singer & Sheinberg, 2006), naming of the target halves for aligned composites was slowed when the irrelevant halves were from faces with a different name compared to that from the original face. However, no interference was observed when the irrelevant halves had identical names as the target halves but came from different learned faces, arguing against a true holistic effect. Instead, response interference was obtained when the target halves briefly preceded the irrelevant halves. Experiment 2 confirmed a double-dissociation between holistic processing vs. response interference for intact faces vs. temporally separated face halves, suggesting that simultaneous presentation of facial information is critical for holistic processing. PMID:21327378

  12. Dynamic visual noise reduces confidence in short-term memory for visual information.

    PubMed

    Kemps, Eva; Andrade, Jackie

    2012-05-01

    Previous research has shown effects of the visual interference technique, dynamic visual noise (DVN), on visual imagery, but not on visual short-term memory, unless retention of precise visual detail is required. This study tested the prediction that DVN does also affect retention of gross visual information, specifically by reducing confidence. Participants performed a matrix pattern memory task with three retention interval interference conditions (DVN, static visual noise and no interference control) that varied from trial to trial. At recall, participants indicated whether or not they were sure of their responses. As in previous research, DVN did not impair recall accuracy or latency on the task, but it did reduce recall confidence relative to static visual noise and no interference. We conclude that DVN does distort visual representations in short-term memory, but standard coarse-grained recall measures are insensitive to these distortions.

  13. Wind-tunnel investigation of effect of interference on lateral-stability characteristics of four NACA 23012 wings, an elliptical and a circular fuselage and vertical fins

    NASA Technical Reports Server (NTRS)

    House, Rufus O; Wallace, Arthur R

    1941-01-01

    Report presents the results of a wind-tunnel investigation of the effect of wing-fuselage interference on lateral-stability characteristics made in the NACA 7 by 10-foot wind tunnel on four fuselages and two fins, representing high-wing, low-wing, and midwing monoplanes. The fuselages are of circular and elliptical cross section. The wings have rounded tips and, in plan form, one is rectangular and the three are tapered 3:1 with various amounts of sweep. The rate of change in the coefficients of rolling moment, yawing moment, and lateral force with angle of yaw is given in a form to show the increment caused by wing-fuselage interference for the model with no fin and the effect of wing-fuselage interference on fin effectiveness. Results for the fuselage-fin combination and the wing tested alone are also given.

  14. The Influence of Similarity on Visual Working Memory Representations

    PubMed Central

    Lin, Po-Han; Luck, Steven J.

    2007-01-01

    In verbal memory, similarity between items in memory often leads to interference and impaired memory performance. The present study sought to determine whether analogous interference effects would be observed in visual working memory by varying the similarity of the to-be-remembered objects in a color change-detection task. Instead of leading to interference and impaired performance, increased similarity among the items being held in memory led to improved performance. Moreover, when two similar colors were presented along with one dissimilar color, memory performance was better for the similar colors than for the dissimilar color. Similarity produced better performance even when the objects were presented sequentially and even when memory for the first item in the sequence was tested. These findings show that similarity does not lead to interference between representations in visual working memory. Instead, similarity may lead to improved task performance, possibly due to increased stability or precision of the memory representations during maintenance. PMID:19430536

  15. Simulated propeller slipstream effects on a supercritical wing

    NASA Technical Reports Server (NTRS)

    Welge, H. R.; Crowder, J. P.

    1978-01-01

    To quantify the installed performance of high speed (M = 0.8) turboprop propulsion systems, an experimental program designed to assess the magnitude of the aerodynamic interference of a propeller slipstream on a supercritical wing has been conducted. The test was conducted in the NASA Ames 14-foot wind tunnel. An ejector-nacelle propeller slipstream simulator was used to produce a slipstream with characteristics typical of advanced propellers presently being investigated. A supercritical wing-body configuration was used to evaluate the interference effects. A traversing total pressure rake was used to make flow field measurements behind the wing and to calibrate the slipstream simulator. The force results indicated that the interference drag amounted to an increase of ten counts or about 3% of the wing-body drag for a two engine configuration at the nominal propeller operating conditions. However, at the higher swirl angles (11 deg vs. 7 deg nominally) the interference drag was favorable by about the same magnitude.

  16. Ultrawideband Electromagnetic Interference to Aircraft Radios: Results of Limited Functional Testing With United Airlines and Eagles Wings Incorporated, in Victorville, California

    NASA Technical Reports Server (NTRS)

    Ely, Jay J.; Shaver, Timothy W.; Fuller, Gerald L.

    2002-01-01

    On February 14, 2002, the FCC adopted a FIRST REPORT AND ORDER, released it on April 22, 2002, and on May 16, 2002 published in the Federal Register a Final Rule, permitting marketing and operation of new products incorporating UWB technology. Wireless product developers are working to rapidly bring this versatile, powerful and expectedly inexpensive technology into numerous consumer wireless devices. Past studies addressing the potential for passenger-carried portable electronic devices (PEDs) to interfere with aircraft electronic systems suggest that UWB transmitters may pose a significant threat to aircraft communication and navigation radio receivers. NASA, United Airlines and Eagles Wings Incorporated have performed preliminary testing that clearly shows the potential for handheld UWB transmitters to cause cockpit failure indications for the air traffic control radio beacon system (ATCRBS), blanking of aircraft on the traffic alert and collision avoidance system (TCAS) displays, and cause erratic motion and failure of instrument landing system (ILS) localizer and glideslope pointers on the pilot horizontal situation and attitude director displays. This report provides details of the preliminary testing and recommends further assessment of aircraft systems for susceptibility to UWB electromagnetic interference.

  17. SOAC - State-of-the-Art Car Engineering Tests at Department of Transportation High Speed Ground Test Center : Volume 5. Structural, Voltage, and Radio Frequency Interference Tests

    DOT National Transportation Integrated Search

    1975-01-01

    The six-volume report presents the technical methodology, data samples, and results of tests conducted on the SOAC on the Rail Transit Test Track at the High Speed Ground Test Center in Pueblo, Colorado during the period April to July 1973. The Test ...

  18. A fast, robust algorithm for power line interference cancellation in neural recording.

    PubMed

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. The proposed algorithm features a highly robust operation, fast adaptation to interference variations, significant SNR improvement, low computational complexity and memory requirement and straightforward parameter adjustment. These features render the algorithm suitable for wearable and implantable sensor applications, where reliable and real-time cancellation of the interference is desired.

  19. A fast, robust algorithm for power line interference cancellation in neural recording

    NASA Astrophysics Data System (ADS)

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Objective. Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. Approach. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. Main results. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. Significance. The proposed algorithm features a highly robust operation, fast adaptation to interference variations, significant SNR improvement, low computational complexity and memory requirement and straightforward parameter adjustment. These features render the algorithm suitable for wearable and implantable sensor applications, where reliable and real-time cancellation of the interference is desired.

  20. Shared Processing of Language and Music.

    PubMed

    Atherton, Ryan P; Chrobak, Quin M; Rauscher, Frances H; Karst, Aaron T; Hanson, Matt D; Steinert, Steven W; Bowe, Kyra L

    2018-01-01

    The present study sought to explore whether musical information is processed by the phonological loop component of the working memory model of immediate memory. Original instantiations of this model primarily focused on the processing of linguistic information. However, the model was less clear about how acoustic information lacking phonological qualities is actively processed. Although previous research has generally supported shared processing of phonological and musical information, these studies were limited as a result of a number of methodological concerns (e.g., the use of simple tones as musical stimuli). In order to further investigate this issue, an auditory interference task was employed. Specifically, participants heard an initial stimulus (musical or linguistic) followed by an intervening stimulus (musical, linguistic, or silence) and were then asked to indicate whether a final test stimulus was the same as or different from the initial stimulus. Results indicated that mismatched interference conditions (i.e., musical - linguistic; linguistic - musical) resulted in greater interference than silence conditions, with matched interference conditions producing the greatest interference. Overall, these results suggest that processing of linguistic and musical information draws on at least some of the same cognitive resources.

  1. Memory consolidation and contextual interference effects with computer games.

    PubMed

    Shewokis, Patricia A

    2003-10-01

    Some investigators of the contextual interference effect contend that there is a direct relation between the amount of practice and the contextual interference effect based on the prediction that the improvement in learning tasks in a random practice schedule, compared to a blocked practice schedule, increases in magnitude as the amount of practice during acquisition on the tasks increases. Research using computer games in contextual interference studies has yielded a large effect (f = .50) with a random practice schedule advantage during transfer. These investigations had a total of 36 and 72 acquisition trials, respectively. The present study tested this prediction by having 72 college students, who were randomly assigned to a blocked or random practice schedule, practice 102 trials of three computer-game tasks across three days. After a 24-hr. interval, 6 retention and 5 transfer trials were performed. Dependent variables were time to complete an event in seconds and number of errors. No significant differences were found for retention and transfer. These results are discussed in terms of how the amount of practice, task-related factors, and memory consolidation mediate the contextual interference effect.

  2. Ranitidine interference with standard amphetamine immunoassay.

    PubMed

    Liu, Li; Wheeler, Sarah E; Rymer, Jacqueline A; Lower, Darla; Zona, Jayne; Peck Palmer, Octavia M; Tamama, Kenichi

    2015-01-01

    We recently encountered several cases of possible false positive results of amphetamine on the Beckman Coulter AMPH assay, but not on the Siemens EMIT II Plus assay. Our clinical chart review suggested that ranitidine interference may be responsible for the false positive results of the AMPH assays. Blank urine specimens spiked with ranitidine concentrations ranging from 5μg/ml to 5mg/ml were analyzed on both the AMPH and EMIT II Plus assays. To examine if the false positive results were due to assay specific reagent/sample ratios, we prepared 3 different sample to reagent ratios and analyzed them for amphetamine reaction rates on both assays. Ranitidine at 160μg/ml caused a positive interference on the AMPH assay. No interference was observed by ranitidine on the EMIT II Plus assay. Specifically, the sample to reagent ratios tested neither eliminated the positive inference on the AMP assay nor introduced an interference on the EMIT II Plus assay. Unlike the EMIT II Plus assay, the AMPH assay has cross-activity with ranitidine, which is independent of sample to reagent ratio. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

    PubMed

    Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique

    2018-03-01

    Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Using a simulation model to assess risk of false negative point-of-care urinary human chorionic gonadotropin device results due to high-dose hook interference.

    PubMed

    Milhorn, Denise; Korpi-Steiner, Nichole

    2015-02-01

    It is unclear if the point-of-care (POC) Clinitest hCG device is subject to high-dose hook interference from physiological concentrations of intact human chorionic gonadotropin (hCG), β-core fragment of hCG (hCGβcf), and hCG free β-subunit (hCGβ) found in urine during pregnancy. We used a simulation model to address this question and related our findings to our institution's pregnant population in order to assess risk for potential false-negative hCG results. The expected distribution of days relative to ovulation during routine POC hCG testing was estimated from 182 patients. Clinitest-Clinitek Status hCG device susceptibility to high-dose hook interference from hCG variants and potential risk of false-negative results as it relates to this population were evaluated by testing increasing concentrations of hCG, hCGβcf, hCGβ as well as urine simulating physiological hCG, hCGβcf and hCGβ concentrations expected during early pregnancy (≤44 days post-ovulation). The Clinitest-Clinitek Status hCG device exhibited high-dose hook interference from hCGβcf alone, but not from hCG, hCGβ, or simulated physiological urinary concentrations of combined hCG, hCGβcf and hCGβ expected during early pregnancy. The majority of our patient population had urinary hCG testing conducted during early pregnancy. The Clinitest-Clinitek Status hCG device is unlikely to exhibit false-negative urinary hCG results due to high-dose hook interference for women in early healthy pregnancy, although additional studies are necessary to determine potential risk in other patient populations. Visual interpretation of POC urinary hCG device results is an important failure mode to consider in risk analyses for erroneous urinary hCG device results. Published by Elsevier Inc.

  5. Rapid eye movement and non-rapid eye movement sleep contributions in memory consolidation and resistance to retroactive interference for verbal material.

    PubMed

    Deliens, Gaétane; Leproult, Rachel; Neu, Daniel; Peigneux, Philippe

    2013-12-01

    To test the hypothesis that rapid eye movement (REM) sleep contributes to the consolidation of new memories, whereas non-rapid eye movement (NREM) sleep contributes to the prevention of retroactive interference. Randomized, crossover study. Two sessions of either a morning nap or wakefulness. Twenty-five healthy young adults. Declarative learning of word pairs followed by a nap or a wake interval, then learning of interfering word pairs and delayed recall of list A. After a restricted night (24:00-06:00), participants learned a list of word pairs (list A). They were then required to either take a nap or stay awake during 45 min, after which they learned a second list of word pairs (list B) and then had to recall list A. Fifty percent of word pairs in list B shared the first word with list A, resulting in interference. Ten subjects exhibited REM sleep whereas 13 subjects exhibited NREM stage 3 (N3) sleep. An interference effect was observed in the nap but not in the wake condition. In post-learning naps, N3 sleep was associated with a reduced interference effect, which was not the case for REM sleep. Moreover, participants exhibiting N3 sleep in the post-learning nap condition also showed a reduced interference effect in the wake condition, suggesting a higher protection ability against interference. Our results partly support the hypothesis that non-rapid eye movement sleep contributes in protecting novel memories against interference. However, rapid eye movement sleep-related consolidation is not evidenced.

  6. Locata Performance Evaluation in the Presence of Wide- and Narrow-Band Interference

    NASA Astrophysics Data System (ADS)

    Khan, Faisal A.; Rizos, Chris; Dempster, Andrew G.

    Classically difficult positioning environments often call for augmentation technology to assist the GPS, or more generally the Global Navigation Satellite System (GNSS) technology. The ground-based ranging technology offers augmentation, and even replacement, to GPS in such environments. However, like any other system relying on wireless technology, a Locata positioning network also faces issues in the presence of RF interference (RFI). This problem is magnified due to the fact that Locata operates in the licence-free 2·4 GHz Industrial, Scientific and Medical (ISM) band. The licence-free nature of this band attracts a much larger number of devices using a wider range of signal types than for licensed bands, resulting in elevation of the noise floor. Also, harmonics from out-of-band signals can act as potential interferers. WiFi devices operating in this band have been identified as the most likely potential interferer, due partially to their use of the whole ISM band, but also because Locata applications often also may use a wireless network. This paper evaluates the performance of Locata in the presence of both narrow- and wide-band interfering signals. Effects of received interference on both raw measurements and final solutions are reported and analysed. Test results show that Locata performance degrades in the presence of received interference. It is also identified that high levels of received interference can affect Locata carriers even if the interference is not in co-frequency situation with the affected carrier. Finally, Locata characteristics have been identified which can be exploited to mitigate RFI issues.

  7. Is Nocturnal Foraging in a Tropical Bee an Escape From Interference Competition?

    PubMed Central

    Kitchen, Shannon M.; Toney, Ryan M.; Ziegler, Christian

    2017-01-01

    Temporal niche partitioning may result from interference competition if animals shift their activity patterns to avoid aggressive competitors. If doing so also shifts food sources, it is difficult to distinguish the effects of interference and consumptive competition in selecting for temporal niche shift. Bees compete for pollen and nectar from flowers through both interference and consumptive competition, and some species of bees have evolved nocturnality. Here, we use tropical forest canopy towers to observe bees (the night-flying sweat bees Megalopta genalis and M. centralis [Halictidae], honey bees, and stingless bees [Apidae]) visiting flowers of the balsa tree (Ochroma pyramalidae, Malvaceae). Because Ochroma flowers are open in the late afternoon through the night we can test the relative influence of each competition type on temporal nice. Niche shift due to consumptive competition predicts that Megalopta forage when resources are available: from afternoon into the night. Niche shift due to interference competition predicts that Megalopta forage only in the absence of diurnal bees. We found no overlap between diurnal bees and Megalopta in the evening, and only one instance of overlap in the morning, despite the abundance of pollen and nectar in the late afternoon and evening. This supports the hypothesis that Megalopta are avoiding interference competition, but not the hypothesis that they are limited by consumptive competition. We propose that the release from interference competition enables Megalopta to provision cells quickly, and spend most of their time investing in nest defense. Thus, increases in foraging efficiency directly resulting from temporal shifts to escape interference competition may indirectly lead to reduced predation and parasitism. PMID:28931157

  8. [Research on lateral shearing interferometer for field monitoring of natural gas pipeline leak].

    PubMed

    Zhang, Xue-Feng; Gao, Yu-Bin

    2012-09-01

    Aimed at the mechanical scanning spectroscopy equipment with poor anti-interference and anti-jamming ability, which affects the accuracy of its natural gas pipeline leak detection in the wild, a new type of lateral shearing interferometer system was designed. The system uses a beam splitter to get optical path difference by a mechanical scanning part, and it cancel the introduction of external vibration interference through the linkage between the two beam splitterw. The interference intensity of interference fringes produced was calculated, and analysis of a rotating beam splitter corresponds to the angle of the optical path difference function, solving for the maximum angle of the forward rotation and reverse rotation, which is the maximum optical path range. Experiments using the gas tank deflated simulated natural gas pipeline leak process, in the interference conditions, and the test data of the type WQF530 spectrometer and the new type of lateral shearing interferometer system were comparedt. The experimental results show that the relative error of both systems is about 1% in indoor conditions without interference. However, in interference environment, the error of WQF530 type spectrometer becomes larger, more than 10%, but the error of the new type of lateral shearing interferometer system is still below 5%. The detection accuracy of the type WQF530 spectrometer decreased significantly due to the environment. Therefore, the seismic design of the system can effectively offset power deviation and half-width increases of center wavelength caused by external interference, and compared to conventional mechanical scanning interferometer devices the new system is more suitable for field detection.

  9. Testing Enhances Subsequent Learning in Older but Not in Younger Elementary School Children

    ERIC Educational Resources Information Center

    Aslan, Alp; Bäuml, Karl-Heinz T.

    2016-01-01

    In adults, testing can enhance subsequent learning by reducing interference from the tested information. Here, we examined this forward effect of testing in children. Younger and older elementary school children and adult controls studied four lists of items in anticipation of a final cumulative recall test. Following presentation of each of the…

  10. The Unintentional Memory Load in Tests for Young Children.

    ERIC Educational Resources Information Center

    Jones, Margaret Hubbard

    The validity of certain standardized tests may be affected by the short-term memory load therein and its relation to a child's short-term memory capacity. Factors of testing which increase a test's memory load and consequently interfere with comprehension are discussed. It is hypothesized that a test which strains the short-term memory capacity of…

  11. The role of physical digit representation and numerical magnitude representation in children's multiplication fact retrieval.

    PubMed

    De Visscher, Alice; Noël, Marie-Pascale; De Smedt, Bert

    2016-12-01

    Arithmetic facts, in particular multiplication tables, are thought to be stored in long-term memory and to be interference prone. At least two representations underpinning these arithmetic facts have been suggested: a physical representation of the digits and a numerical magnitude representation. We hypothesized that both representations are possible sources of interference that could explain individual differences in multiplication fact performance and/or in strategy use. We investigated the specificity of these interferences on arithmetic fact retrieval and explored the relation between interference and performance on the different arithmetic operations and on general mathematics achievement. Participants were 79 fourth-grade children (M age =9.6 years) who completed a products comparison and a multiplication production task with verbal strategy reports. Performances on a speeded calculation test including the four operations and on a general mathematics achievement test were also collected. Only the interference coming from physical representations was a significant predictor of the performance across multiplications. However, both the magnitude and physical representations were unique predictors of individual differences in multiplication. The frequency of the retrieval strategy across multiplication problems and across individuals was determined only by the physical representation, which therefore is suggested as being responsible for memory storage issues. Interestingly, this impact of physical representation was not observed when predicting performance on subtraction or on general mathematical achievement. In contrast, the impact of the numerical magnitude representation was more general in that it was observed across all arithmetic operations and in general mathematics achievement. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Effects of validating communication on recall during a pain-task in healthy participants.

    PubMed

    Carstens, Johan K P; Boersma, Katja; Schrooten, Martien G S; Linton, Steven J

    2017-10-01

    Increasing recall of instructions and advice in a pain consultation is important, since it is a prerequisite for adherence to treatment recommendations. However, interference due to pain-related distress may result in poor recall. Whereas there are some indications that recall can be increased by empathic communication that reduces interference, this interesting possibility remains largely untested experimentally. The current experiment aimed at studying effects of empathic communication, and more specifically validation, on recall during a pain test and possible mediators and moderators of this effect. Participants received either validating (N=25) or invalidating responses (N=25) from the experimenter during a pain provoking task, followed by self-report measures of interference (affect, situational pain catastrophizing) and recall (accurate and false memories of words). As expected, the validated group exhibited higher accurate recall and less false memories following the pain test as compared to the invalidated group. This was partly due to the effect of interference being counteracted by moderating the relationship between pain catastrophizing and recall. These novel results suggest that validating communication can counteract interference due to pain catastrophizing on recall, at least in a controlled experimental setting. Good communication by health professionals is of utmost importance for adherence to pain management. The current results expand our knowledge on the effects of pain communication by establishing and explaining a clear link between empathic communication and recall, highlighting the role of pain catastrophizing. Copyright © 2017 Scandinavian Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  13. Effects of cruise engine location and power on interference

    NASA Technical Reports Server (NTRS)

    Bradley, D.

    1972-01-01

    Data are presented, in plotted form, of tests for determining the interference effects of space shuttle booster cruise engine location for power-on and power-off conditions. The tests were conducted in a 7 x 10 foot transonic wind tunnel; the model was a 0.015-scale space shuttle booster specially equipped for propulsion effects testing. Data were obtained over a Mach number range of 0.4 to 1.13 at angles of attack from -4 deg to 20 deg at zero degrees sideslip and at angles of sideslip from -6 deg to +6 deg at constant angles of attack of 0 deg, 6 deg, 15 deg, and in some cases 10 deg. Additional parameters investigated were: elevon deflection, canard deflection, aileron deflection, rudder deflection, canard position, and mass flow rate.

  14. KSC-05PD-1073

    NASA Technical Reports Server (NTRS)

    2005-01-01

    KENNEDY SPACE CENTER, FLA. In the Payload Hazardous Servicing Facility, an electromagnetic interference verification test is being conducted on the solar arrays for the Mars Reconnaissance Orbiter (MRO) and an antenna simulator (yellow horizontal rod). If no interference is found during the test, the Shallow Radar Antenna (SHARAD) will be installed on the spacecraft. The spacecraft is undergoing multiple mechanical assembly operations and electrical tests to verify its readiness for launch. The MRO was built by Lockheed Martin for NASAs Jet Propulsion Laboratory in California. It is the next major step in Mars exploration and scheduled for launch from Launch Complex 41 at Cape Canaveral Air Force Station in a window opening Aug. 10. The MRO is an important next step in fulfilling NASAs vision of space exploration and ultimately sending human explorers to Mars and beyond.

  15. Measurement Equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS®) Pain Interference Short Form Items: Application to Ethnically Diverse Cancer and Palliative Care Populations.

    PubMed

    Teresi, Jeanne A; Ocepek-Welikson, Katja; Cook, Karon F; Kleinman, Marjorie; Ramirez, Mildred; Reid, M Carrington; Siu, Albert

    2016-01-01

    Reducing the response burden of standardized pain measures is desirable, particularly for individuals who are frail or live with chronic illness, e.g., those suffering from cancer and those in palliative care. The Patient Reported Outcome Measurement Information System ® (PROMIS ® ) project addressed this issue with the provision of computerized adaptive tests (CAT) and short form measures that can be used clinically and in research. Although there has been substantial evaluation of PROMIS item banks, little is known about the performance of PROMIS short forms, particularly in ethnically diverse groups. Reviewed in this article are findings related to the differential item functioning (DIF) and reliability of the PROMIS pain interference short forms across diverse sociodemographic groups. DIF hypotheses were generated for the PROMIS short form pain interference items. Initial analyses tested item response theory (IRT) model assumptions of unidimensionality and local independence. Dimensionality was evaluated using factor analytic methods; local dependence (LD) was tested using IRT-based LD indices. Wald tests were used to examine group differences in IRT parameters, and to test DIF hypotheses. A second DIF-detection method used in sensitivity analyses was based on ordinal logistic regression with a latent IRT-derived conditioning variable. Magnitude and impact of DIF were investigated, and reliability and item and scale information statistics were estimated. The reliability of the short form item set was excellent. However, there were a few items with high local dependency, which affected the estimation of the final discrimination parameters. As a result, the item, "How much did pain interfere with enjoyment of social activities?" was excluded in the DIF analyses for all subgroup comparisons. No items were hypothesized to show DIF for race and ethnicity; however, five items showed DIF after adjustment for multiple comparisons in both primary and sensitivity analyses: ability to concentrate, enjoyment of recreational activities, tasks away from home, participation in social activities, and socializing with others. The magnitude of DIF was small and the impact negligible. Three items were consistently identified with DIF for education: enjoyment of life, ability to concentrate, and enjoyment of recreational activities. No item showed DIF above the magnitude threshold and the impact of DIF on the overall measure was minimal. No item showed gender DIF after correction for multiple comparisons in the primary analyses. Four items showed consistent age DIF: enjoyment of life, ability to concentrate, day to day activities, and enjoyment of recreational activities, none with primary magnitude values above threshold. Conditional on the pain state, Spanish speakers were hypothesized to report less pain interference on one item, enjoyment of life. The DIF findings confirmed the hypothesis; however, the magnitude was small. Using an arbitrary cutoff point of theta ( θ ) ≥ 1.0 to classify respondents with acute pain interference, the highest number of changes were for the education groups analyses. There were 231 respondents (4% of the total sample) who changed from the designation of no acute pain interference to acute interference after the DIF adjustment. There was no change in the designations for race/ethnic subgroups, and a small number of changes for respondents aged 65 to 84. Although significant DIF was observed after correction for multiple comparisons, all DIF was of low magnitude and impact. However, some individual-level impact was observed for low education groups. Reliability estimates were high. Thus, the PROMIS short form pain items examined in this ethnically diverse sample performed relatively well; although one item was problematic and removed from the analyses. It is concluded that the majority of the PROMIS pain interference short form items can be recommended for use among ethnically diverse groups, including those in palliative care and with cancer and chronic illness.

  16. Measurement Equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS®) Pain Interference Short Form Items: Application to Ethnically Diverse Cancer and Palliative Care Populations

    PubMed Central

    Teresi, Jeanne A.; Ocepek-Welikson, Katja; Cook, Karon F.; Kleinman, Marjorie; Ramirez, Mildred; Reid, M. Carrington; Siu, Albert

    2017-01-01

    Reducing the response burden of standardized pain measures is desirable, particularly for individuals who are frail or live with chronic illness, e.g., those suffering from cancer and those in palliative care. The Patient Reported Outcome Measurement Information System® (PROMIS®) project addressed this issue with the provision of computerized adaptive tests (CAT) and short form measures that can be used clinically and in research. Although there has been substantial evaluation of PROMIS item banks, little is known about the performance of PROMIS short forms, particularly in ethnically diverse groups. Reviewed in this article are findings related to the differential item functioning (DIF) and reliability of the PROMIS pain interference short forms across diverse sociodemographic groups. Methods DIF hypotheses were generated for the PROMIS short form pain interference items. Initial analyses tested item response theory (IRT) model assumptions of unidimensionality and local independence. Dimensionality was evaluated using factor analytic methods; local dependence (LD) was tested using IRT-based LD indices. Wald tests were used to examine group differences in IRT parameters, and to test DIF hypotheses. A second DIF-detection method used in sensitivity analyses was based on ordinal logistic regression with a latent IRT-derived conditioning variable. Magnitude and impact of DIF were investigated, and reliability and item and scale information statistics were estimated. Results The reliability of the short form item set was excellent. However, there were a few items with high local dependency, which affected the estimation of the final discrimination parameters. As a result, the item, “How much did pain interfere with enjoyment of social activities?” was excluded in the DIF analyses for all subgroup comparisons. No items were hypothesized to show DIF for race and ethnicity; however, five items showed DIF after adjustment for multiple comparisons in both primary and sensitivity analyses: ability to concentrate, enjoyment of recreational activities, tasks away from home, participation in social activities, and socializing with others. The magnitude of DIF was small and the impact negligible. Three items were consistently identified with DIF for education: enjoyment of life, ability to concentrate, and enjoyment of recreational activities. No item showed DIF above the magnitude threshold and the impact of DIF on the overall measure was minimal. No item showed gender DIF after correction for multiple comparisons in the primary analyses. Four items showed consistent age DIF: enjoyment of life, ability to concentrate, day to day activities, and enjoyment of recreational activities, none with primary magnitude values above threshold. Conditional on the pain state, Spanish speakers were hypothesized to report less pain interference on one item, enjoyment of life. The DIF findings confirmed the hypothesis; however, the magnitude was small. Using an arbitrary cutoff point of theta (θ) ≥ 1.0 to classify respondents with acute pain interference, the highest number of changes were for the education groups analyses. There were 231 respondents (4% of the total sample) who changed from the designation of no acute pain interference to acute interference after the DIF adjustment. There was no change in the designations for race/ethnic subgroups, and a small number of changes for respondents aged 65 to 84. Conclusions Although significant DIF was observed after correction for multiple comparisons, all DIF was of low magnitude and impact. However, some individual-level impact was observed for low education groups. Reliability estimates were high. Thus, the PROMIS short form pain items examined in this ethnically diverse sample performed relatively well; although one item was problematic and removed from the analyses. It is concluded that the majority of the PROMIS pain interference short form items can be recommended for use among ethnically diverse groups, including those in palliative care and with cancer and chronic illness. PMID:28983449

  17. Parameter Sensitivity Study of the Wall Interference Correction System (WICS)

    NASA Technical Reports Server (NTRS)

    Walker, Eric L.; Everhart, Joel L.; Iyer, Venkit

    2001-01-01

    An off-line version of the Wall Interference Correction System (WICS) has been implemented for the "NASA Langley National Transonic Facility. The correction capability is currently restricted to corrections for solid wall interference in the model pitch plane for Mach numbers, less than 0.45 due to a limitation in tunnel calibration data. A study to assess output sensitivity to the aerodynamic parameters of Reynolds number and Mach number was conducted on this code to further ensure quality during the correction process. In addition, this paper includes all investigation into possible correction due to a semispan test technique using a non metric standoff and all improvement to the standard data rejection algorithm.

  18. EMGAN: A computer program for time and frequency domain reduction of electromyographic data

    NASA Technical Reports Server (NTRS)

    Hursta, W. N.

    1975-01-01

    An experiment in electromyography utilizing surface electrode techniques was developed for the Apollo-Soyuz test project. This report describes the computer program, EMGAN, which was written to provide first order data reduction for the experiment. EMG signals are produced by the membrane depolarization of muscle fibers during a muscle contraction. Surface electrodes detect a spatially summated signal from a large number of muscle fibers commonly called an interference pattern. An interference pattern is usually so complex that analysis through signal morphology is extremely difficult if not impossible. It has become common to process EMG interference patterns in the frequency domain. Muscle fatigue and certain myopathic conditions are recognized through changes in muscle frequency spectra.

  19. Virtual targeting in three-dimensional space with sound and light interference

    NASA Astrophysics Data System (ADS)

    Chua, Florence B.; DeMarco, Robert M.; Bergen, Michael T.; Short, Kenneth R.; Servatius, Richard J.

    2006-05-01

    Law enforcement and the military are critically concerned with the targeting and firing accuracy of opponents. Stimuli which impede opponent targeting and firing accuracy can be incorporated into defense systems. An automated virtual firing range was developed to assess human targeting accuracy under conditions of sound and light interference, while avoiding dangers associated with live fire. This system has the ability to quantify sound and light interference effects on targeting and firing accuracy in three dimensions. This was achieved by development of a hardware and software system that presents the subject with a sound or light target, preceded by a sound or light interference. SonyXplod. TM 4-way speakers present sound interference and sound targeting. The Martin ® MiniMAC TM Profile operates as a source of light interference, while a red laser light serves as a target. A tracking system was created to monitor toy gun movement and firing in three-dimensional space. Data are collected via the Ascension ® Flock of Birds TM tracking system and a custom National Instrument ® LabVIEW TM 7.0 program to monitor gun movement and firing. A test protocol examined system parameters. Results confirm that the system enables tracking of virtual shots from a fired simulation gun to determine shot accuracy and location in three dimensions.

  20. Importance of Pain Acceptance in Relation to Headache Disability and Pain Interference in Women with Migraine and Overweight/Obesity

    PubMed Central

    Lillis, Jason; Thomas, J. Graham; Seng, Elizabeth K.; Lipton, Richard B.; Pavlovic, Jelena; Rathier, Lucille; Roth, Julie; O’Leary, Kevin C.; Bond, Dale S.

    2018-01-01

    BACKGROUND Pain acceptance involves willingness to experience pain and engaging in valued activities while pain is present. Though pain acceptance could limit both headache-related disability and pain interference in individuals with migraine, few studies have addressed this issue. The current study evaluated whether higher levels of total pain acceptance and it’s 2 subcomponents, pain willingness and activity engagement, were associated with lower levels of headache-related impairment in women who had both migraine and overweight/obesity. METHODS In this cross-sectional study, participants seeking weight loss and headache relief in the Women’s Health and Migraine (WHAM) trial completed baseline measures of pain acceptance (Chronic Pain Acceptance Questionnaire [CPAQ]), headache-related disability (Headache Impact Test-6 [HIT-6]), and pain interference (Brief Pain Inventory [BPI]). Migraine headache frequency and pain intensity were assessed daily via smartphone diary. Using CPAQ total and subcomponent (pain willingness and activity engagement) scores, headache frequency, pain intensity, and BMI as predictors in linear regression, headache-related disability and pain interference were modeled as outcomes. RESULTS On average, participants (n=126; age=38.5±8.2 years; BMI=35.3±6.6 kg/m2) reported 8.4±4.7 migraine days/month and pain intensity of 6.0±1.5 on a 0–10 scale on headache days. After correcting for multiple comparisons (adjusted α=.008), pain willingness was independently associated with both lower headache related disability (p<.001; β=−.233) and pain interference (p<.001; β= −.261). Activity engagement was not associated with headache related disability (p=.128; β= −.138) and pain interference (p=.042; β= −.154). CPAQ Total Score was not associated with headache related disability (p=.439; β=.066) and pain interference (p=.305; β=.074). Pain intensity was significantly associated with outcomes in all analyses (p’s <.001; β’s .343−.615). CONCLUSIONS Higher pain willingness, independent of degree of both migraine severity and overweight, is associated with lower headache-related disability and general pain interference in treatment-seeking women with migraine and overweight/obesity. Future studies are needed to clarify direction of causality and test whether strategies designed to help women increase pain willingness, or relinquish ineffective efforts to control pain, can improve functional outcomes in women who have migraine and overweight/obesity. PMID:28295273

  1. Wind Tunnel Interference Effects on Tilt Rotor Testing Using Computational Fluid Dynamics

    NASA Technical Reports Server (NTRS)

    Koning, Witold J. F.

    2015-01-01

    Experimental techniques to measure rotorcraft aerodynamic performance are widely used. However, most of them are either unable to capture interference effects from bodies, or require an extremely large computational budget. The objective of the present research is to develop an XV-15 Tilt Rotor Research Aircraft rotor model for investigation of wind tunnel wall interference using a novel Computational Fluid Dynamics (CFD) solver for rotorcraft, RotCFD. In RotCFD, a mid-fidelity URANS solver is used with an incompressible flow model and a realizable k-e turbulence model. The rotor is, however, not modeled using a computationally expensive, unsteady viscous body-fitted grid, but is instead modeled using a blade element model with a momentum source approach. Various flight modes of the XV-15 isolated rotor, including hover, tilt and airplane mode, have been simulated and correlated to existing experimental and theoretical data. The rotor model is subsequently used for wind tunnel wall interference simulations in the National Full-Scale Aerodynamics Complex (NFAC) at NASA Ames Research Center in California. The results from the validation of the isolated rotor performance showed good correlation with experimental and theoretical data. The results were on par with known theoretical analyses. In RotCFD the setup, grid generation and running of cases is faster than many CFD codes, which makes it a useful engineering tool. Performance predictions need not be as accurate as high-fidelity CFD codes, as long as wall effects can be properly simulated. For both test sections of the NFAC wall interference was examined by simulating the XV-15 rotor in the test section of the wind tunnel and with an identical grid but extended boundaries in free field. Both cases were also examined with an isolated rotor or with the rotor mounted on the modeled geometry of the Tiltrotor Test Rig (TTR). A 'quasi linear trim' was used to trim the thrust for the rotor to compare the power as a unique variable. Power differences between free field and wind tunnel cases were found from -7 % to 0 % in the 80- by 120-Foot Wind Tunnel test section and -1.6 % to 4.8 % in the 40- by 80-Foot Wind Tunnel, depending on the TTR orientation, tunnel velocity and blade setting. The TTR will be used in 2016 to test the Bell 609 rotor in a similar fashion to the research in this report.

  2. The development of a self-streamlining flexible walled transonic test section

    NASA Technical Reports Server (NTRS)

    Goodyer, M. J.; Wolf, S. W. D.

    1980-01-01

    This design eliminates the uncertainties in data from conventional transonic test sections. Sidewalls are rigid, and the flexible floor and ceiling are positioned by motorized jacks controlled by on-line computer to minimize run times. The tunnel-computer combination is self-streamlining without reference to the model. Data is taken from the model only when the walls are good streamlines, and is corrected for the small, known but inevitable residual interferences. Two-dimensional validation testing in the Mach range up to about 0.85 where the walls are just supercritical shows good agreement with reference data using a height:chord ratio of 1.5. Techniques are under development to extend Mach number above 1. This work has demonstrated the feasibility of almost eliminating wall interferences, improving flow quality, and reducing power requirements or increasing Reynolds number. Extensions to three-dimensional testing are outlined.

  3. Testing for EMC (electromagnetic compatibility) in the clinical environment.

    PubMed

    Paperman, D; David, Y; Martinez, M

    1996-01-01

    Testing for electromagnetic compatibility (EMC) in the clinical environment introduces a host of complex conditions not normally encountered under laboratory conditions. In the clinical environment, various radio-frequency (RF) sources of electromagnetic interference (EMI) may be present throughout the entire spectrum of interest. Isolating and analyzing the impact from the sources of interference to medical devices involves a multidisciplinary approach based on training in, and knowledge of, the following: operation of medical devices and their susceptibility to EMI; RF propagation modalities and interaction theory; spectrum analysis systems and techniques (preferably with signature analysis capabilities) and calibrated antennas; the investigation methodology of suspected EMC problems, and testing protocols and standards. Using combinations of standard test procedures adapted for the clinical environment with personnel that have an understanding of radio-frequency behavior increases the probability of controlling, proactively, EMI in the clinical environment, thus providing for a safe and more effective patient care environment.

  4. Electromagnetic interference with cardiac pacemakers and implantable cardioverter-defibrillators from low-frequency electromagnetic fields in vivo.

    PubMed

    Tiikkaja, Maria; Aro, Aapo L; Alanko, Tommi; Lindholm, Harri; Sistonen, Heli; Hartikainen, Juha E K; Toivonen, Lauri; Juutilainen, Jukka; Hietanen, Maila

    2013-03-01

    Electromagnetic interference (EMI) can pose a danger to workers with pacemakers and implantable cardioverter-defibrillators (ICDs). At some workplaces electromagnetic fields are high enough to potentially inflict EMI. The purpose of this in vivo study was to evaluate the susceptibility of pacemakers and ICDs to external electromagnetic fields. Eleven volunteers with a pacemaker and 13 with an ICD were exposed to sine, pulse, ramp, and square waveform magnetic fields with frequencies of 2-200 Hz using Helmholtz coil. The magnetic field flux densities varied to 300 µT. We also tested the occurrence of EMI from an electronic article surveillance (EAS) gate, an induction cooktop, and a metal inert gas (MIG) welding machine. All pacemakers were tested with bipolar settings and three of them also with unipolar sensing configurations. None of the bipolar pacemakers or ICDs tested experienced interference in any of the exposure situations. The three pacemakers with unipolar settings were affected by the highest fields of the Helmholtz coil, and one of them also by the EAS gate and the welding cable. The induction cooktop did not interfere with any of the unipolarly programmed pacemakers. Magnetic fields with intensities as high as those used in this study are rare even in industrial working environments. In most cases, employees can return to work after implantation of a bipolar pacemaker or an ICD, after an appropriate risk assessment. Pacemakers programmed to unipolar configurations can cause danger to their users in environments with high electromagnetic fields, and should be avoided, if possible.

  5. Can Testing Immunize Memories against Interference?

    ERIC Educational Resources Information Center

    Potts, Rosalind; Shanks, David R.

    2012-01-01

    Testing typically enhances subsequent recall of tested material. In contrast, it has been proposed that consolidated memories can be destabilized when reactivated and then need to be reconsolidated in order to persist. Learning new material immediately after reactivation may disrupt reconsolidation. We investigated whether the well-known benefits…

  6. Design, Fabrication and Characterization of Micro Opto-Electro-Mechanical Systems.

    DTIC Science & Technology

    1995-12-01

    interference problems (see Fig. 3-6). Improvements in the lithography of the MCNC process would allow for grating spaces of less than 2 gm and therefore...A micro-spectrometer has been fabricated using LIGA, an acronym for lithography , electroforming, and micromolding (the acronym came from the German...location for test samples and an adjustable mirror. The beams are brought back together to form an interference pattern. At an observation screen the

  7. User's guide to PANCOR: A panel method program for interference assessment in slotted-wall wind tunnels

    NASA Technical Reports Server (NTRS)

    Kemp, William B., Jr.

    1990-01-01

    Guidelines are presented for use of the computer program PANCOR to assess the interference due to tunnel walls and model support in a slotted wind tunnel test section at subsonic speeds. Input data requirements are described in detail and program output and general program usage are described. The program is written for effective automatic vectorization on a CDC CYBER 200 class vector processing system.

  8. The Effect of Nacelle-Propeller Diameter Ratio on Body Interference and on Propeller and Cooling Characteristics

    NASA Technical Reports Server (NTRS)

    Mchugh, James G; Derring, Eldridge H

    1939-01-01

    Report presents the results of an investigation conducted in the NACA 20-foot tunnel to determine the slipstream drag, the body interference, and the cooling characteristics of nacelle-propeller diameter. Four combinations of geometrically similar propellers and nacelles, mounted on standard wing supports, were tested with values of the ratio of nacelle diameter to propeller diameter of 0.25, 0.33, and 0.44.

  9. Tonic Inhibitory Control of Dentate Gyrus Granule Cells by α5-Containing GABAA Receptors Reduces Memory Interference.

    PubMed

    Engin, Elif; Zarnowska, Ewa D; Benke, Dietmar; Tsvetkov, Evgeny; Sigal, Maksim; Keist, Ruth; Bolshakov, Vadim Y; Pearce, Robert A; Rudolph, Uwe

    2015-10-07

    Interference between similar or overlapping memories formed at different times poses an important challenge on the hippocampal declarative memory system. Difficulties in managing interference are at the core of disabling cognitive deficits in neuropsychiatric disorders. Computational models have suggested that, in the normal brain, the sparse activation of the dentate gyrus granule cells maintained by tonic inhibitory control enables pattern separation, an orthogonalization process that allows distinct representations of memories despite interference. To test this mechanistic hypothesis, we generated mice with significantly reduced expression of the α5-containing GABAA (α5-GABAARs) receptors selectively in the granule cells of the dentate gyrus (α5DGKO mice). α5DGKO mice had reduced tonic inhibition of the granule cells without any change in fast phasic inhibition and showed increased activation in the dentate gyrus when presented with novel stimuli. α5DGKO mice showed impairments in cognitive tasks characterized by high interference, without any deficiencies in low-interference tasks, suggesting specific impairment of pattern separation. Reduction of fast phasic inhibition in the dentate gyrus through granule cell-selective knock-out of α2-GABAARs or the knock-out of the α5-GABAARs in the downstream CA3 area did not detract from pattern separation abilities, which confirms the anatomical and molecular specificity of the findings. In addition to lending empirical support to computational hypotheses, our findings have implications for the treatment of interference-related cognitive symptoms in neuropsychiatric disorders, particularly considering the availability of pharmacological agents selectively targeting α5-GABAARs. Interference between similar memories poses a significant limitation on the hippocampal declarative memory system, and impaired interference management is a cognitive symptom in many disorders. Thus, understanding mechanisms of successful interference management or processes that can lead to interference-related memory problems has high theoretical and translational importance. This study provides empirical evidence that tonic inhibition in the dentate gyrus (DG), which maintains sparseness of neuronal activation in the DG, is essential for management of interference. The specificity of findings to tonic, but not faster, more transient types of neuronal inhibition and to the DG, but not the neighboring brain areas, is presented through control experiments. Thus, the findings link interference management to a specific mechanism, proposed previously by computational models. Copyright © 2015 the authors 0270-6474/15/3513699-15$15.00/0.

  10. Problems analysis and new fabrication strategies of mediated electrochemical biosensors for wastewater toxicity assessment.

    PubMed

    Yang, Yajie; Fang, Deyu; Liu, Yanran; Liu, Runze; Wang, Xiaoshen; Yu, Yuan; Zhi, Jinfang

    2018-06-15

    Conventional mediated electrochemical biosensors for toxicity assessment were almost based on 'one-pot' principle, i.e., mediators and the under-test chemicals were mixed together in the same vessel. In this process, the electron mediator is assumed to be merely an electron acceptor and cannot react with under-test toxicants. Actually,some under-test pollutants (such as metal ions) could react with the electron mediators, thus affecting the detection accuracy and sensitivity of the sensors. It was also found that at least two other interference factors have been ignored in present'one-pot' mediated electrochemical biosensor systems, i.e., (1) the electrochemical sensitivity of mediators to pH; and (2) the potential reactions between under-test chemicals and buffers and the consequent pH changes. In this study, the three ignored interference factors have been investigated systematically and demonstrated by significance tests. Moreover, a solving strategy, an isolation method, is proposed for fabrication of novel mediated electrochemical biosensor to avoid the interference factors existing at present mediated electrochemical biosensor. According to the testing results obtained from the isolation method, IC 50 values of Cu 2+ , Cd 2+ , Zn 2+ , Fe 3+ , Ni 2+ and Cr 3+ were 21.3 mg/L, 3.7 mg/L, 26.7 mg/L, 4.4 mg/L and 10.7 mg/L, respectively. The detection results of four real water samples also suggested this method could be applied for the practical and complex samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Friction coefficient and effective interference at the implant-bone interface.

    PubMed

    Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E

    2015-09-18

    Although the contact pressure increases during implantation of a wedge-shaped implant, friction coefficients tend to be measured under constant contact pressure, as endorsed in standard procedures. Abrasion and plastic deformation of the bone during implantation are rarely reported, although they define the effective interference, by reducing the nominal interference between implant and bone cavity. In this study radial forces were analysed during simulated implantation and explantation of angled porous and polished implant surfaces against trabecular bone specimens, to determine the corresponding friction coefficients. Permanent deformation was also analysed to determine the effective interference after implantation. For the most porous surface tested, the friction coefficient initially increased with increasing normal contact stress during implantation and then decreased at higher contact stresses. For a less porous surface, the friction coefficient increased continually with normal contact stress during implantation but did not reach the peak magnitude measured for the rougher surface. Friction coefficients for the polished surface were independent of normal contact stress and much lower than for the porous surfaces. Friction coefficients were slightly lower for pull-out than for push-in for the porous surfaces but not for the polished surface. The effective interference was as little as 30% of the nominal interference for the porous surfaces. The determined variation in friction coefficient with radial contact force, as well as the loss of interference during implantation will enable a more accurate representation of implant press-fitting for simulations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. "The mute who can sing": a cortical stimulation study on singing.

    PubMed

    Roux, Franck-Emmanuel; Borsa, Stefano; Démonet, Jean-François

    2009-02-01

    In an attempt to identify cortical areas involved in singing in addition to language areas, the authors used a singing task during direct cortical mapping in 5 patients who were amateur singers and had undergone surgery for brain tumors. The organization of the cortical areas involved in language and singing was analyzed in relation with these surgical data. One left-handed and 4 right-handed patients with brain tumors in left (2 cases) and right (3 cases) hemispheres and no significant language or singing deficits underwent surgery with the "awake surgery" technique. All patients had a special interest in singing and were involved in amateur singing activities. They were tested using naming, reading, and singing tasks. Outside primary sensorimotor areas, singing interferences were rare and were exclusively localized in small cortical areas (< 1 cm(2)). A clear distinction was found between speech and singing in the Broca region. In the Broca region, no singing interference was found in areas in which interference in naming and reading tasks were detected. Conversely, a specific singing interference was found in nondominant middle frontal gyri in one patient. This interference consisted of abrupt singing arrest without apparent face, mouth, and tongue contraction. Finally, nonspecific singing interferences were found in the right and left precentral gyri in all patients (probably by interference in final articulatory mechanisms of singing). Dissociations between speech and singing found outside primary sensorimotor areas showed that these 2 functions use, in some cortical stages, different cerebral pathways.

  13. Testing during Study Insulates against the Buildup of Proactive Interference

    ERIC Educational Resources Information Center

    Szpunar, Karl K.; McDermott, Kathleen B.; Roediger, Henry L., III

    2008-01-01

    Recent interest in the benefits of retrieval practice on long-term retention--the testing effect--has spawned a considerable amount of research toward understanding the underlying nature of this ubiquitous memory phenomenon. Taking a test may benefit retention through both direct means (engaging appropriate retrieval processes) and indirect means…

  14. In the Eye of the Examinee: Likable Examiners Interfere with Performance

    ERIC Educational Resources Information Center

    Vormittag, Isabella; Ortner, Tuulia M.

    2014-01-01

    We investigated effects of examiners' ascribed likability and examiners' gender on test performance during a standardized face-to-face testing situation assessing self-estimated and de facto verbal knowledge. One hundred fourteen nonpsychology students were individually tested by one of 22 examiners. A moderated regression analysis…

  15. Interference and problem size effect in multiplication fact solving: Individual differences in brain activations and arithmetic performance.

    PubMed

    De Visscher, Alice; Vogel, Stephan E; Reishofer, Gernot; Hassler, Eva; Koschutnig, Karl; De Smedt, Bert; Grabner, Roland H

    2018-05-15

    In the development of math ability, a large variability of performance in solving simple arithmetic problems is observed and has not found a compelling explanation yet. One robust effect in simple multiplication facts is the problem size effect, indicating better performance for small problems compared to large ones. Recently, behavioral studies brought to light another effect in multiplication facts, the interference effect. That is, high interfering problems (receiving more proactive interference from previously learned problems) are more difficult to retrieve than low interfering problems (in terms of physical feature overlap, namely the digits, De Visscher and Noël, 2014). At the behavioral level, the sensitivity to the interference effect is shown to explain individual differences in the performance of solving multiplications in children as well as in adults. The aim of the present study was to investigate the individual differences in multiplication ability in relation to the neural interference effect and the neural problem size effect. To that end, we used a paradigm developed by De Visscher, Berens, et al. (2015) that contrasts the interference effect and the problem size effect in a multiplication verification task, during functional magnetic resonance imaging (fMRI) acquisition. Forty-two healthy adults, who showed high variability in an arithmetic fluency test, participated in our fMRI study. In order to control for the general reasoning level, the IQ was taken into account in the individual differences analyses. Our findings revealed a neural interference effect linked to individual differences in multiplication in the left inferior frontal gyrus, while controlling for the IQ. This interference effect in the left inferior frontal gyrus showed a negative relation with individual differences in arithmetic fluency, indicating a higher interference effect for low performers compared to high performers. This region is suggested in the literature to be involved in resolution of proactive interference. Besides, no correlation between the neural problem size effect and multiplication performance was found. This study supports the idea that the interference due to similarities/overlap of physical traits (the digits) is crucial in memorizing arithmetic facts and in determining individual differences in arithmetic. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.

    PubMed

    Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven

    2015-05-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E).

  17. ADHD and retrieval-induced forgetting: evidence for a deficit in the inhibitory control of memory.

    PubMed

    Storm, Benjamin C; White, Holly A

    2010-04-01

    Research on retrieval-induced forgetting has shown that the selective retrieval of some information can cause the forgetting of other information. Such forgetting is believed to result from inhibitory processes that function to resolve interference during retrieval. The current study examined whether individuals with ADHD demonstrate normal levels of retrieval-induced forgetting. A total of 40 adults with ADHD and 40 adults without ADHD participated in a standard retrieval-induced forgetting experiment. Critically, half of the items were tested using category cues and the other half of the items were tested using category-plus-one-letter-stem cues. Whereas both ADHD and non-ADHD participants demonstrated retrieval-induced forgetting on the final category-cued recall test, only non-ADHD participants demonstrated retrieval-induced forgetting on the final category-plus-stem-cued recall test. These results suggest that individuals with ADHD do have a deficit in the inhibitory control of memory, but that this deficit may only be apparent when output interference is adequately controlled on the final test.

  18. Comparison of the analytical capabilities of the BAC Datamaster and Datamaster DMT forensic breath testing devices.

    PubMed

    Glinn, Michele; Adatsi, Felix; Curtis, Perry

    2011-11-01

    The State of Michigan uses the Datamaster as an evidential breath testing device. The newest version, the DMT, will replace current instruments in the field as they are retired from service. The Michigan State Police conducted comparison studies to test the analytical properties of the new instrument and to evaluate its response to conditions commonly cited in court defenses. The effects of mouth alcohol, objects in the mouth, and radiofrequency interference on paired samples from drinking subjects were assessed on the DMT. The effects of sample duration and chemical interferents were assessed on both instruments, using drinking subjects and wet-bath simulators, respectively. Our testing shows that Datamaster and DMT results are essentially identical; the DMT gave accurate readings as compared with measurements made using simulators containing standard ethanol solutions and that the DMT did not give falsely elevated breath alcohol results from any of the influences tested. © 2011 American Academy of Forensic Sciences.

  19. Indirect potentiometric titration of ascorbic acid in pharmaceutical preparations using copper based mercury film electrode.

    PubMed

    Abdul Kamal Nazer, Meeran Mohideen; Hameed, Abdul Rahman Shahul; Riyazuddin, Patel

    2004-01-01

    A simple and rapid potentiometric method for the estimation of ascorbic acid in pharmaceutical dosage forms has been developed. The method is based on treating ascorbic acid with iodine and titration of the iodide produced equivalent to ascorbic acid with silver nitrate using Copper Based Mercury Film Electrode (CBMFE) as an indicator electrode. Interference study was carried to check possible interference of usual excipients and other vitamins. The precision and accuracy of the method was assessed by the application of lack-of-fit test and other statistical methods. The results of the proposed method and British Pharmacopoeia method were compared using F and t-statistical tests of significance.

  20. Space shuttle: Determination of the aerodynamic interference between the space shuttle orbiter, external tank, and solid rocket booster on a 0.004 scale ascent configuration

    NASA Technical Reports Server (NTRS)

    Ramsey, P. E.; Buchholz, R.; Allen, E. C. JR.; Dehart, J.

    1973-01-01

    Wind tunnel tests were conducted to determine the aerodynamic interference between the space shuttle orbiter, external tank, and solid rocket booster on a 0.004 scale ascent configuration. Six component aerodynamic force and moment data were recorded over an angle of attack range from minus 10 to plus 10 degrees at zero degree sideslip. A sideslip range of minus 10 to plus 10 degrees at zero degree angle of attack was also tested. The Mach number range was varied from 0.6 to 4.96 with Reynolds number varying between 4.9 and 6.8 times one million per foot.

  1. Crew Quarters (CQ) and Electromagnetic Interference (EMI) Measurement Facility Combined Impedance Study

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2011-01-01

    This report documents an investigation into observed failures associated with conducted susceptibility testing of Crew Quarters (CQ) hardware in the Johnson Space Center (JSC) Electromagnetic Interference (EMI) Measurement Facility, and the work accomplished to identify the source of the observed behavior. Investigation led to the conclusion that the hardware power input impedance was interacting with the facility power impedance leading to instability at the observed frequencies of susceptibility. Testing performed in other facilities did not show this same behavior, pointing back to the EMI Measurement Facility power as the potential root cause. A LISN emulating the Station power bus impedance was inserted into the power circuit, and the susceptibility was eliminated from the measurements.

  2. Tabulated pressure measurements on a large subsonic transport model airplane with high bypass ratio, powered, fan jet engines

    NASA Technical Reports Server (NTRS)

    Flechner, S. G.; Patterson, J. C., Jr.

    1972-01-01

    An experimental wind-tunnel investigation to determine the aerodynamic interference and the jet-wake interference associated with the wing, pylon, and high-bypass-ratio, powered, fan-jet model engines has been conducted on a typical high-wing logistics transport airplane configuration. Pressures were measured on the wing and pylons and on the surfaces of the engine fan cowl, turbine cowl, and plug. Combinations of wing, pylons, engines, and flow-through nacelles were tested, and the pressure coefficients are presented in tabular form. Tests were conducted at Mach numbers from 0.700 to 0.825 and angles of attack from -2 to 4 deg.

  3. Vibration modes interference in the MEMS resonant pressure sensor

    NASA Astrophysics Data System (ADS)

    Zhang, Fangfang; Li, Anlin; Bu, Zhenxiang; Wang, Lingyun; Sun, Daoheng; Du, Xiaohui; Gu, Dandan

    2017-11-01

    A new type of coupled balanced-mass double-ended tuning fork resonator (CBDETF) pressure sensor is fabricated and tested. However, the low accuracy of the CBDETF pressure sensor is not satisfied to us. Based on systematic analysis and tests, the coupling effect between the operational mode and interference mode is considered to be the main cause for the sensor in accuracy. To solve this problem, the stiffness of the serpentine beams is increased to pull up the resonant frequency of the interfering mode and make it separate far from the operational mode. Finally, the accuracy of the CBDETF pressure sensor is improved from + /-0.5% to less than + /-0.03% of the Full Scale (F.S.).

  4. Is Nocturnal Foraging in a Tropical Bee an Escape From Interference Competition?

    PubMed

    Smith, Adam R; Kitchen, Shannon M; Toney, Ryan M; Ziegler, Christian

    2017-01-01

    Temporal niche partitioning may result from interference competition if animals shift their activity patterns to avoid aggressive competitors. If doing so also shifts food sources, it is difficult to distinguish the effects of interference and consumptive competition in selecting for temporal niche shift. Bees compete for pollen and nectar from flowers through both interference and consumptive competition, and some species of bees have evolved nocturnality. Here, we use tropical forest canopy towers to observe bees (the night-flying sweat bees Megalopta genalis and M. centralis [Halictidae], honey bees, and stingless bees [Apidae]) visiting flowers of the balsa tree (Ochroma pyramalidae, Malvaceae). Because Ochroma flowers are open in the late afternoon through the night we can test the relative influence of each competition type on temporal nice. Niche shift due to consumptive competition predicts that Megalopta forage when resources are available: from afternoon into the night. Niche shift due to interference competition predicts that Megalopta forage only in the absence of diurnal bees. We found no overlap between diurnal bees and Megalopta in the evening, and only one instance of overlap in the morning, despite the abundance of pollen and nectar in the late afternoon and evening. This supports the hypothesis that Megalopta are avoiding interference competition, but not the hypothesis that they are limited by consumptive competition. We propose that the release from interference competition enables Megalopta to provision cells quickly, and spend most of their time investing in nest defense. Thus, increases in foraging efficiency directly resulting from temporal shifts to escape interference competition may indirectly lead to reduced predation and parasitism. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America.

  5. A Polyamine Oxidizing Enzyme as a Drug to Treat Breast Cancer

    DTIC Science & Technology

    2007-07-01

    is a viable anticancer therapy. BODY TASK 1. Prepare enough of two polyethylene glycol(PEG)-derivatives of bovine serum amine oxidase (SAO...interfere with its PEGylation and/or obscure the outcome of experiments to test the treatment as an anticancer therapy. Hence, another few weeks were...attached polysaccharide , thus, minimize interference with or mimicking of the mouse’s own SAO. A small amount of bovine SAO was PEGylated at pH 7.4 with

  6. Les Interferences Semantiques Dans Les Oeuvres D'ahmadou Kourouma et De Mongo Beti: Essai D'etude Comparative [Semantic Interference in the Works of Ahmadou Kourouma and Mongo Beti: Test Comparative Study

    ERIC Educational Resources Information Center

    Tadoum, Jean Paul

    2012-01-01

    This dissertation focuses on the works of two well-known African Francophone novelists, Ahmadou Kourouma from the Ivory Coast and Mongo Beti from Cameroon. The objective of this study is to look at the influences of African oral traditions and analyze the literary transposition of semantic structures from African languages and cultures into the…

  7. Modern wireless telecommunication technologies and their electromagnetic compatibility with life-supporting equipment.

    PubMed

    Wallin, Mats K E B; Marve, Therese; Hakansson, Peter K

    2005-11-01

    Hospitals rely on pagers and ordinary telephones to reach staff members in emergency situations. New telecommunication technologies such as General Packet Radio Service (GPRS), the third generation mobile phone system Universal Mobile Telecommunications System (UMTS), and Wireless Local Area Network (WLAN) might be able to replace hospital pagers if they are electromagnetically compatible with medical devices. In this study, we sought to determine if GPRS, UMTS (Wideband Code Division Multiple Access-Frequency Division Duplex [WCDMA FDD]), and WLAN (IEEE 802.11b) transmitted signals interfere with life-supporting equipment in the intensive care and operating room environment. According to United States standard, ANSI C63.18-1997, laboratory tests were performed on 76 medical devices. In addition, clinical tests during 11 operations and 100 h of intensive care were performed. UMTS and WLAN signals caused little interference. Devices using these technologies can be used safely in critical care areas and during operations, but direct contact between medical devices and wireless communication devices ought to be avoided. In the case of GPRS, at a distance of 50 cm, it caused an older infusion pump to alarm and stop infusing; the pump had to be reset. Also, 10 cases of interference with device displays occurred. GPRS can be used safely at a distance of 1 m. Terminals/cellular phones using these technologies should be allowed without restriction in public areas because the risk of interference is minimal.

  8. Beyond interference control impairment in ADHD: evidence from increased intraindividual variability in the color-stroop test.

    PubMed

    Borella, Erika; de Ribaupierre, Anik; Cornoldi, Cesare; Chicherio, Christian

    2013-09-01

    The present study investigates intraindividual variability (IIV) in the Color-Stroop test and in a simple reaction time (SRT) task. Performance level and variability in reaction times (RTs)-quantified with different measures such as individual standard deviation (ISD) and coefficient of variation (ICV), as well as ex-Gaussian parameters (mu, sigma, tau)-were analyzed in 24 children with attention deficit/hyperactivity disorder (ADHD) and 24 typically developing children (TDC). Children with ADHD and TDC presented equivalent Color-Stroop interference effects when mean RTs were considered, and the two groups did not differ in the SRT task. Interestingly, compared to TDC, children with ADHD were more variable in their responses, showing increased ISD and ICV in the Color-Stroop interference condition and in the SRT task. Moreover, children with ADHD exhibited higher tau values-that is, more frequent abnormally long RTs-in the Color-Stroop interference condition than did the TDC, but comparable tau values in the SRT, suggesting more variable responses. These results speak in favor of a general deficit in more basic and central processes that only secondarily may affect the efficiency of inhibitory processes in children with ADHD. Overall the present findings confirm the role of IIV as a cornerstone in the ADHD cognitive profile and support the search for fine-grained analysis of performance fluctuations.

  9. Interference of avian guano in analyses of fuel-contaminated soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, D.E.; Johnson, T.E.; Kreamer, D.K.

    1996-01-01

    Site characterization on Johnston Island, Johnston Atoll, Pacific Ocean, has yielded preliminary data that seabird guano can be an interference in three common petroleum hydrocarbon quantification methods. Volatiles from seabird guano were measured on a hydrocarbon-specific handheld vapor meter (catalytic detector) in concentrations as high as 256 ppm by volume total hydrocarbon. Analysis of guano solids produced measurable concentrations of total petroleum hydrocarbon (TPH) as diesel using both an immunoassay test and the EPA 8015 Modified Method. The testing was conducted on one surface sample of guano collected from a seabird roosting and nesting area. Source species were not identified.more » Positive hydrocarbon test results for guano raise concerns regarding the effectiveness of standard methods of petroleum-contaminated site characterization for Johnston island, other Pacific islands, and coastal areas with historic or contemporary seabird populations.« less

  10. ANALYSIS OF ALDEHYDES AND KETONES IN THE GAS PHASE

    EPA Science Inventory

    The development and testing of a 2,4-dinitrophenylhydrazine-acetonitrile (DNPH-ACN) method for the analysis of aldehydes and ketones in ambient air are described. A discussion of interferences, preparation of calibration standards, analytical testing, fluorescence methods and car...

  11. A tension insensitive PbS fiber temperature sensor based on Sagnac interferometer

    NASA Astrophysics Data System (ADS)

    Fu, Xing-hu; Zhang, Jiang-peng; Yang, Kai-li; Dong, Yan-hua; Wen, Jian-xiang; Fu, Guang-wei; Bi, Wei-hong

    2017-03-01

    In this paper, a tension insensitive PbS fiber temperature sensor based on Sagnac interferometer is proposed and demonstrated. The sensing mechanism of tension and temperature is analyzed. The relationships between the interference spectrum, temperature and tension are analyzed, respectively. The experimental temperature range is 36—70 °C. The experimental results show that the interference spectrum is red shifted, and its sensitivity is 53.89 pm/°C. In tension experiment, the tension range is 0—1 400 μɛ. The experimental results show that there is no wavelength shift in the interference spectrum. The sensor is immune to tension cross-sensitivity compared with other sensors. It can be used for temperature testing in aerospace, chemistry and pharmacy.

  12. Advances in Measurement of Skin Friction in Airflow

    NASA Technical Reports Server (NTRS)

    Brown, James L.; Naughton, Jonathan W.

    2006-01-01

    The surface interferometric skin-friction (SISF) measurement system is an instrument for determining the distribution of surface shear stress (skin friction) on a wind-tunnel model. The SISF system utilizes the established oil-film interference method, along with advanced image-data-processing techniques and mathematical models that express the relationship between interferograms and skin friction, to determine the distribution of skin friction over an observed region of the surface of a model during a single wind-tunnel test. In the oil-film interference method, a wind-tunnel model is coated with a thin film of oil of known viscosity and is illuminated with quasi-monochromatic, collimated light, typically from a mercury lamp. The light reflected from the outer surface of the oil film interferes with the light reflected from the oil-covered surface of the model. In the present version of the oil-film interference method, a camera captures an image of the illuminated model and the image in the camera is modulated by the interference pattern. The interference pattern depends on the oil-thickness distribution on the observed surface, and this distribution can be extracted through analysis of the image acquired by the camera. The oil-film technique is augmented by a tracer technique for observing the streamline pattern. To make the streamlines visible, small dots of fluorescentchalk/oil mixture are placed on the model just before a test. During the test, the chalk particles are embedded in the oil flow and produce chalk streaks that mark the streamlines. The instantaneous rate of thinning of the oil film at a given position on the surface of the model can be expressed as a function of the instantaneous thickness, the skin-friction distribution on the surface, and the streamline pattern on the surface; the functional relationship is expressed by a mathematical model that is nonlinear in the oil-film thickness and is known simply as the thin-oil-film equation. From the image data acquired as described, the time-dependent oil-thickness distribution and streamline pattern are extracted and by inversion of the thin-oil-film equation it is then possible to determine the skin-friction distribution. In addition to a quasi-monochromatic light source, the SISF system includes a beam splitter and two video cameras equipped with filters for observing the same area on a model in different wavelength ranges, plus a frame grabber and a computer for digitizing the video images and processing the image data. One video camera acquires the interference pattern in a narrow wavelength range of the quasi-monochromatic source. The other video camera acquires the streamline image of fluorescence from the chalk in a nearby but wider wavelength range. The interference- pattern and fluorescence images are digitized, and the resulting data are processed by an algorithm that inverts the thin-oil-film equation to find the skin-friction distribution.

  13. Adaptive wall technology for minimization of wall interferences in transonic wind tunnels

    NASA Technical Reports Server (NTRS)

    Wolf, Stephen W. D.

    1988-01-01

    Modern experimental techniques to improve free air simulations in transonic wind tunnels by use of adaptive wall technology are reviewed. Considered are the significant advantages of adaptive wall testing techniques with respect to wall interferences, Reynolds number, tunnel drive power, and flow quality. The application of these testing techniques relies on making the test section boundaries adjustable and using a rapid wall adjustment procedure. A historical overview shows how the disjointed development of these testing techniques, since 1938, is closely linked to available computer support. An overview of Adaptive Wall Test Section (AWTS) designs shows a preference for use of relatively simple designs with solid adaptive walls in 2- and 3-D testing. Operational aspects of AWTS's are discussed with regard to production type operation where adaptive wall adjustments need to be quick. Both 2- and 3-D data are presented to illustrate the quality of AWTS data over the transonic speed range. Adaptive wall technology is available for general use in 2-D testing, even in cryogenic wind tunnels. In 3-D testing, more refinement of the adaptive wall testing techniques is required before more widespread use can be planned.

  14. Research on signal processing of shock absorber test bench based on zero-phase filter

    NASA Astrophysics Data System (ADS)

    Wu, Yi; Ding, Guoqing

    2017-10-01

    The quality of force-displacement diagram is significant to help evaluate the performance of shock absorbers. Damping force sampling data is often interfered by Gauss white noise, 50Hz power interference and its harmonic wave during the process of testing; data de-noising has become the core problem of drawing true, accurate and real-time indicator diagram. The noise and interference can be filtered out through generic IIR or FIR low-pass filter, but addition phase lag of useful signal will be caused due to the inherent attribute of IIR and FIR filter. The paper uses FRR method to realize zero-phase digital filtering in a software way based on mutual cancellation of phase lag between the forward and reverse sequences after through the filter. High-frequency interference above 40Hz are filtered out completely and noise attenuation is more than -40dB, with no additional phase lag. The method is able to restore the true signal as far as possible. Theoretical simulation and practical test indicate high-frequency noises have been effectively inhibited in multiple typical speed cases, signal-to-noise ratio being greatly improved; the curve in indicator diagram has better smoothness and fidelity. The FRR algorithm has low computational complexity, fast running time, and can be easily transplanted in multiple platforms.

  15. Misdiagnosis of Graves' Disease with Apparent Severe Hyperthyroidism in a Patient Taking Biotin Megadoses.

    PubMed

    Barbesino, Giuseppe

    2016-06-01

    Accurate immunoassays measuring minute quantities of hormones are the cornerstone of the practice of endocrinology. Despite tremendous advances in this field, novel pitfalls in these tests emerge from time to time. Oral biotin can interfere with immunoassays of several hormones. The purpose of this report is to relate an extreme case of such interference. A patient with progressive multiple sclerosis was found to have extremely elevated free thyroxine, triiodothyronine, and suppressed thyrotropin (TSH) levels. His TSH receptor binding inhibiting antibody level was also elevated. This constellation of laboratory findings suggested a diagnosis of severe Graves' disease. All of the assays yielding abnormal results employed the biotin-streptavidin affinity in their design. The patient had no symptoms of hyperthyroidism, and detailed review of his medications revealed intake of megadoses of biotin. Temporary discontinuation of biotin treatment resulted in complete resolution of the biochemical abnormalities. Non-physiologic biotin supplementation may interfere with several immunoassays, including thyroid hormones, TSH, thyroglobulin, and TSH receptor binding inhibiting antibody, leading to erroneous diagnoses. Questioning for biotin intake should be part of the evaluation for patients undergoing endocrine tests. Interruption of biotin supplementation for at least two days prior to biotin-sensitive tests should be sufficient to avoid major misdiagnoses.

  16. The Role of Inflammation in the Pain, Fatigue, and Sleep Disturbance Symptom Cluster in Advanced Cancer.

    PubMed

    Kwekkeboom, Kristine L; Tostrud, Lauren; Costanzo, Erin; Coe, Christopher L; Serlin, Ronald C; Ward, Sandra E; Zhang, Yingzi

    2018-05-01

    Symptom researchers have proposed a model of inflammatory cytokine activity and dysregulation in cancer to explain co-occurring symptoms including pain, fatigue, and sleep disturbance. We tested the hypothesis that psychological stress accentuates inflammation and that stress and inflammation contribute to one's experience of the pain, fatigue, and sleep disturbance symptom cluster (symptom cluster severity, symptom cluster distress) and its impact (symptom cluster interference with daily life, quality of life). We used baseline data from a symptom cluster management trial. Adult participants (N = 158) receiving chemotherapy for advanced cancer reported pain, fatigue, and sleep disturbance on enrollment. Before intervention, participants completed measures of demographics, perceived stress, symptom cluster severity, symptom cluster distress, symptom cluster interference with daily life, and quality of life and provided a blood sample for four inflammatory biomarkers (interleukin-1β, interleukin-6, tumor necrosis factor-α, and C-reactive protein). Stress was not directly related to any inflammatory biomarker. Stress and tumor necrosis factor-α were positively related to symptom cluster distress, although not symptom cluster severity. Tumor necrosis factor-α was indirectly related to symptom cluster interference with daily life, through its effect on symptom cluster distress. Stress was positively associated with symptom cluster interference with daily life and inversely with quality of life. Stress also had indirect effects on symptom cluster interference with daily life, through its effect on symptom cluster distress. The proposed inflammatory model of symptoms was partially supported. Investigators should test interventions that target stress as a contributing factor in co-occurring pain, fatigue, and sleep disturbance and explore other factors that may influence inflammatory biomarker levels within the context of an advanced cancer diagnosis and treatment. Copyright © 2018 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  17. Chimeric recombinant antibody fragments in cardiac troponin I immunoassay.

    PubMed

    Hyytiä, Heidi; Heikkilä, Taina; Brockmann, Eeva-Christine; Kekki, Henna; Hedberg, Pirjo; Puolakanaho, Tarja; Lövgren, Timo; Pettersson, Kim

    2015-03-01

    To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to

  18. Suppression of emission rates improves sonar performance by flying bats.

    PubMed

    Adams, Amanda M; Davis, Kaylee; Smotherman, Michael

    2017-01-31

    Echolocating bats face the challenge of actively sensing their environment through their own emissions, while also hearing calls and echoes of nearby conspecifics. How bats mitigate interference is a long-standing question that has both ecological and technological implications, as biosonar systems continue to outperform man-made sonar systems in noisy, cluttered environments. We recently showed that perched bats decreased calling rates in groups, displaying a behavioral strategy resembling the back-off algorithms used in artificial communication networks to optimize information throughput at the group level. We tested whether free-tailed bats (Tadarida brasiliensis) would employ such a coordinated strategy while performing challenging flight maneuvers, and report here that bats navigating obstacles lowered emission rates when hearing artificial playback of another bat's calls. We measured the impact of acoustic interference on navigation performance and show that the calculated reductions in interference rates are sufficient to reduce interference and improve obstacle avoidance. When bats flew in pairs, each bat responded to the presence of the other as an obstacle by increasing emissions, but hearing the sonar emissions of the nearby bat partially suppressed this response. This behavior supports social cohesion by providing a key mechanism for minimizing mutual interference.

  19. Interatomic interaction effects on second-order momentum correlations and Hong-Ou-Mandel interference of double-well-trapped ultracold fermionic atoms

    NASA Astrophysics Data System (ADS)

    Brandt, Benedikt B.; Yannouleas, Constantine; Landman, Uzi

    2018-05-01

    Identification and understanding of the evolution of interference patterns in two-particle momentum correlations as a function of the strength of interatomic interactions are important in explorations of the nature of quantum states of trapped particles. Together with the analysis of two-particle spatial correlations, they offer the prospect of uncovering fundamental symmetries and structure of correlated many-body states, as well as opening vistas into potential control and utilization of correlated quantum states as quantum-information resources. With the use of the second-order density matrix constructed via exact diagonalization of the microscopic Hamiltonian, and an analytic Hubbard-type model, we explore here the systematic evolution of characteristic interference patterns in the two-body momentum and spatial correlation maps of two entangled ultracold fermionic atoms in a double well, for the entire attractive- and repulsive-interaction range. We uncover quantum-statistics-governed bunching and antibunching, as well as interaction-dependent interference patterns, in the ground and excited states, and interpret our results in light of the Hong-Ou-Mandel interference physics, widely exploited in photon indistinguishability testing and quantum-information science.

  20. Suppression of emission rates improves sonar performance by flying bats

    PubMed Central

    Adams, Amanda M.; Davis, Kaylee; Smotherman, Michael

    2017-01-01

    Echolocating bats face the challenge of actively sensing their environment through their own emissions, while also hearing calls and echoes of nearby conspecifics. How bats mitigate interference is a long-standing question that has both ecological and technological implications, as biosonar systems continue to outperform man-made sonar systems in noisy, cluttered environments. We recently showed that perched bats decreased calling rates in groups, displaying a behavioral strategy resembling the back-off algorithms used in artificial communication networks to optimize information throughput at the group level. We tested whether free-tailed bats (Tadarida brasiliensis) would employ such a coordinated strategy while performing challenging flight maneuvers, and report here that bats navigating obstacles lowered emission rates when hearing artificial playback of another bat’s calls. We measured the impact of acoustic interference on navigation performance and show that the calculated reductions in interference rates are sufficient to reduce interference and improve obstacle avoidance. When bats flew in pairs, each bat responded to the presence of the other as an obstacle by increasing emissions, but hearing the sonar emissions of the nearby bat partially suppressed this response. This behavior supports social cohesion by providing a key mechanism for minimizing mutual interference. PMID:28139707

Top