  1. Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

    PubMed

    Kolega, Marija Škara; Kovačević, Suzana; Čanović, Samir; Pavičić, Ana Didović; Bašić, Jadranka Katušić

    2015-03-01

    Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included in this prospective randomized trial. Twenty eyes underwent IOL master and 20 eyes had aplanation ultrasound biometry. There were included only eyes with age-related cataract and postoperative natural visual acuity (VA) 0.7. Visual acuity was performed 6 weeks after cataract surgery. After 6 weeks best natural visual acuity were 0.9 (± 0.1) in IOL-Master group and 0.85 (± 0.15) in ultrasound biometry. The postoperative mean absolute refractive error was 0.75 (± 0.5) D for ultrasound biometry and 0.50 (± 0.50) D for IOL-Master. Optical biometry with the IOL-Master proved to be slightly more accurate than ultrasound biometry for IOL power calculation.

  2. Comparison of anterior segment parameters and axial length measurements performed on a Scheimpflug device with biometry function and a reference optical biometer.

    PubMed

    Muzyka-Woźniak, Maria; Oleszko, Adam

    2018-04-26

    To compare measurements of axial length (AL), corneal curvature (K), anterior chamber depth (ACD) and white-to-white (WTW) distance on a new device combining Scheimpflug camera and partial coherence interferometry (Pentacam AXL) with a reference optical biometer (IOL Master 500). To evaluate differences between IOL power calculations based on the two biometers. Ninety-seven eyes of 97 consecutive cataract or refractive lens exchange patients were examined preoperatively on IOL Master 500 and Pentacam AXL units. Comparisons between two devices were performed for AL, K, ACD and WTW. Intraocular lens (IOL) power targeting emmetropia was calculated with SRK/T and Haigis formulas on both devices and compared. There were statistically significant differences between two devices for all measured parameters (P < 0.05), except ACD (P = 0.36). Corneal curvature measured with Pentacam AXL was significantly flatter then with IOL Master. The mean difference in AL was clinically insignificant (0.01 mm; 95% LoA 0.16 mm). Pentacam AXL yielded higher IOL power in 75% of eyes for Haigis formula and in 62% of eyes for SRK/T formula, with a mean difference within ± 0.5 D for 72 and 86% of eyes, respectively. There were statistically significant differences between AL, K and WTW measurements obtained with the compared biometers. Flatter corneal curvature measurements on Pentacam AXL necessitate formulas optimisation for Pentacam AXL.

  3. Comparison of the Corneal Power Measurements with the TMS4-Topographer, Pentacam HR, IOL Master, and Javal Keratometer.

    PubMed

    Dehnavi, Zahra; Khabazkhoob, Mehdi; Mirzajani, Ali; Jabbarvand, Mahmood; Yekta, Abbasali; Jafarzadehpur, Ebrahim

    2015-01-01

    The aim was to compare the corneal curvature and power measured with a corneal topographer, Scheimpflug camera, optical biometer, and Javal keratometer. A total of 76 myopic individuals who were candidates for photorefractive keratectomy were selected in a cross-sectional study. Manual keratometry (Javal Schiotz type; Haag-Streit AG, Koeniz, Switzerland), automated keratometry (IOL Master version 3.02, Carl Zeiss Meditec, Jena, Germany), topography (TMS4, Tomey, Erlangen, Germany), and Pentacam HR (Oculus, Wetzlar, Germany) were performed for all participants. The 95% limits of agreement (LOAs) were reported to evaluate the agreement between devices. The mean corneal power measurements were 44.3 ± 1.59, 44.25 ± 1.59, 43.68 ± 1.44, and 44.31 ± 1.61 D with a Javal keratometer, TMS4-topographer, the Pentacam and IOL Master respectively. Only the IOL Master showed no significant difference with Javal keratometer in measuring the corneal power (P = 0.965). The correlations of the Javal keratometer with TMS4-topography, Pentacam, and IOL Master was 0.991. 0.982, and 0.993 respectively. The 95% LOAs of the Javal keratometer with TMS4-topography, Pentacam, and IOL Master were - 0.361 to 0.49, -0.01 to 1.14, and - 0.36 to 0.36 D, respectively. Although the correlation of Pentacam, TMS4-topography, IOL Master, and Javal keratometer in measuring keratometry was high, only the IOL Master showed no significant difference with the Javal keratometer. The IOL Master had the best agreement with Javal keratometry.

  4. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    PubMed

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (p<0.01), as well as between IOL Master and digital photographs (p<0.01). There was no difference between SL-OCT and digital photographs (p>0.05). All measurements were correlated (Spearman p<0.001). Mean anterior chamber depth determined using the IOL-Master was 2.99 +/- 0.50 mm and by slit-lamp adapted optical coherence tomography was 2.56 +/- 0.46 mm. The difference was statistically significant (p<0.001). The correlation between the values was also statistically significant (Spearman, p<0.001). Automated measurements using IOL-Master yield constantly higher values than measurements based on direct eye visualization slit-lamp adapted optical coherence tomography and digital photographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.

  5. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    PubMed Central

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    AIM To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically. PMID:29181314

  6. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients.

    PubMed

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

  7. Comparison of the Pentacam equivalent keratometry reading and IOL Master keratometry measurement in intraocular lens power calculations.

    PubMed

    Karunaratne, Nicholas

    2013-12-01

    To compare the accuracy of the Pentacam Holladay equivalent keratometry readings with the IOL Master 500 keratometry in calculating intraocular lens power. Non-randomized, prospective clinical study conducted in private practice. Forty-five consecutive normal patients undergoing cataract surgery. Forty-five consecutive patients had Pentacam equivalent keratometry readings at the 2-, 3 and 4.5-mm corneal zone and IOL Master keratometry measurements prior to cataract surgery. For each Pentacam equivalent keratometry reading zone and IOL Master measurement the difference between the observed and expected refractive error was calculated using the Holladay 2 and Sanders, Retzlaff and Kraff theoretic (SRKT) formulas. Mean keratometric value and mean absolute refractive error. There was a statistically significantly difference between the mean keratometric values of the IOL Master, Pentacam equivalent keratometry reading 2-, 3- and 4.5-mm measurements (P < 0.0001, analysis of variance). There was no statistically significant difference between the mean absolute refraction error for the IOL Master and equivalent keratometry readings 2 mm, 3 mm and 4.5 mm zones for either the Holladay 2 formula (P = 0.14) or SRKT formula (P = 0.47). The lowest mean absolute refraction error for Holladay 2 equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.17 D). The lowest mean absolute refraction error for SRKT equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.19 D). Comparing the absolute refraction error of IOL Master and Pentacam equivalent keratometry reading, best agreement was with Holladay 2 and equivalent keratometry reading 4.5 mm, with mean of the difference of 0.02 D and 95% limits of agreement of -0.35 and 0.39 D. The IOL Master keratometry and Pentacam equivalent keratometry reading were not equivalent when used only for corneal power measurements. However, the keratometry measurements of the IOL Master and Pentacam equivalent keratometry reading 4.5 mm may be similarly effective when used in intraocular lens power calculation formulas, following constant optimization. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  8. Impact of nuclear cataract density on postoperative refractive outcome: IOL Master versus ultrasound.

    PubMed

    Ueda, Tetsuo; Taketani, Futoshi; Ota, Takeo; Hara, Yoshiaki

    2007-01-01

    To evaluate the effect of cataract density on the postoperative refractive outcome. For 59 nuclear cataract eyes, the axial length was preoperatively measured by the IOL Master (Zeiss, Germany) and ultrasound (US; UD-6000, Tomey, Japan) and the cataract density by EAS-1000 (Nidek, Japan). The prediction error was used as evaluation of the accuracy of ocular biometry. There were significant differences between IOL Master and US in the mean error (0.24 +/- 0.63 vs. 0.69 +/- 0.64 dpt, p < 0.001) and the mean absolute error (0.57 +/- 0.36 vs. 0.79 +/- 0.53 dpt, p < 0.001). The cataract density was significantly correlated with the prediction error with IOL Master (r = 0.24, p = 0.03) and US (r = 0.29, p = 0.01). Measurements with the IOL Master are slightly affected by the cataract density due to the refractive index change, but its accuracy is less affected than US. (c) 2007 S. Karger AG, Basel.

  9. Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study.

    PubMed

    Pongsachareonnont, Pear; Tangjanyatam, Sagol

    2018-01-01

    We compared the accuracy of axial length (AL) measurement obtained by optical biometry with that obtained by acoustic biometry in eyes with rhegmatogenous retinal detachment (RRD). This prospective descriptive analytic study measured the AL of eyes with RRD preoperatively and 3 months postoperatively using optical biometry (intraocular lens [IOL] master group) and acoustic biometry (immersion A-scan group). Preoperative and postoperative measurements were compared by paired t -test. The agreement between preoperative and postoperative measurements was analyzed using a Bland-Altman plot. Subgroup analysis of macular involvement status was performed. Twenty-seven eyes were analyzed in this study. The mean AL in the IOL master group was 23.58±0.97 mm preoperatively and 24.17±1.16 mm postoperatively; the mean difference was -0.59±0.90 mm ( P = 0.007). The mean AL in the immersion A-scan group was 24.29±1.59 mm preoperatively and 24.27±1.69 mm postoperatively; the mean difference was 0.02±0.48 mm ( P = 0.827). Bland-Altman analysis revealed disagreement between preoperative and postoperative AL measurements in both techniques. In subgroup analysis of macula with RRD, there were significant differences between preoperative and postoperative AL measurements in the IOL master group ( P = 0.014). Significant underestimation of AL measurement was observed when using the IOL master in eyes with RRD with macular involvement, which could affect IOL power selection.

  10. Ray-tracing analysis of intraocular lens power in situ.

    PubMed

    Olsen, Thomas; Funding, Mikkel

    2012-04-01

    To describe a method for back-solving the power of an intraocular lens (IOL) in situ based on laser biometry and ray-tracing analysis of the pseudophakic eye. University Eye Clinic, Aarhus Hospital, Aarhus, Denmark. Evaluation of diagnostic test or technology. This study comprised pseudophakic eyes with an IOL power ranging from -2.00 to +36.00 diopters (D). Preoperatively, the corneal radius was measured with conventional autokeratometry and the axial length (AL) with optical biometry. After surgery, the position of the IOL was recorded using laser interferometry. Based on the postoperative refraction and the biometric measurements, a ray-tracing analysis was performed back-solving for the power of the IOL in situ. The analysis was performed assuming pupil diameters from 0.0 to 8.0 mm with and without correction for the Stiles-Crawford effect. The study evaluated 767 pseudophakic eyes (583 patients). Assuming a 3.0 mm pupil, the mean prediction error between the labeled and the calculated IOL power (± 1 standard deviation [SD]) was -0.26 D ± 0.65 (SD) (range -2.4 to +1.8 D). The prediction error showed no bias with IOL power or with AL. The calculated IOL power depended on the assumed pupil size and the Stiles-Crawford effect. However, the latter had a modulatory effect on the prediction error for large pupil diameters (>5.0 mm) only. The optics of the pseudophakic eye can be accurately described using exact ray tracing and modern biometric techniques. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Comparison of Accuracy in Intraocular Lens Power Calculation by Measuring Axial Length with Immersion Ultrasound Biometry and Partial Coherence Interferometry.

    PubMed

    Ruangsetakit, Varee

    2015-11-01

    To re-examine relative accuracy of intraocular lens (IOL) power calculation of immersion ultrasound biometry (IUB) and partial coherence interferometry (PCI) based on a new approach that limits its interest on the cases in which the IUB's IOL and PCI's IOL assignments disagree. Prospective observational study of 108 eyes that underwent cataract surgeries at Taksin Hospital. Two halves ofthe randomly chosen sample eyes were implanted with the IUB- and PCI-assigned lens. Postoperative refractive errors were measured in the fifth week. More accurate calculation was based on significantly smaller mean absolute errors (MAEs) and root mean squared errors (RMSEs) away from emmetropia. The distributions of the errors were examined to ensure that the higher accuracy was significant clinically as well. The (MAEs, RMSEs) were smaller for PCI of (0.5106 diopter (D), 0.6037D) than for IUB of (0.7000D, 0.8062D). The higher accuracy was principally contributedfrom negative errors, i.e., myopia. The MAEs and RMSEs for (IUB, PCI)'s negative errors were (0.7955D, 0.5185D) and (0.8562D, 0.5853D). Their differences were significant. The 72.34% of PCI errors fell within a clinically accepted range of ± 0.50D, whereas 50% of IUB errors did. PCI's higher accuracy was significant statistically and clinically, meaning that lens implantation based on PCI's assignments could improve postoperative outcomes over those based on IUB's assignments.

  12. Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series.

    PubMed

    Kolozsvári, Bence L; Losonczy, Gergely; Pásztor, Dorottya; Fodor, Mariann

    2017-01-13

    Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and refractive predictability in patients with a previous vitreoretinal surgery can be as good as in uncomplicated cases.

  13. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    PubMed

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p < 0.00001). The number of predictions within +/- 0.5 D, +/- 1.0 D and +/- 2.0 D of the expected outcome was 62.5%, 92.4% and 99.9% with PCI, compared with 45.5%, 77.3% and 98.4% with ultrasound, respectively (p < 0.00001). The 2-variable ACD method resulted in an average error in PCI predictions of 0.46 D, which was significantly higher than the error in the 5-variable method (p < 0.001). The accuracy of IOL power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  14. From master slave interferometry to complex master slave interferometry: theoretical work

    NASA Astrophysics Data System (ADS)

    Rivet, Sylvain; Bradu, Adrian; Maria, Michael; Feuchter, Thomas; Leick, Lasse; Podoleanu, Adrian

    2018-03-01

    A general theoretical framework is described to obtain the advantages and the drawbacks of two novel Fourier Domain Optical Coherence Tomography (OCT) methods denoted as Master/Slave Interferometry (MSI) and its extension denoted as Complex Master/Slave Interferometry (CMSI). Instead of linearizing the digital data representing the channeled spectrum before a Fourier transform can be applied to it (as in OCT standard methods), channeled spectrum is decomposed on the basis of local oscillations. This replaces the need for linearization, generally time consuming, before any calculation of the depth profile in the range of interest. In this model two functions, g and h, are introduced. The function g describes the modulation chirp of the channeled spectrum signal due to nonlinearities in the decoding process from wavenumber to time. The function h describes the dispersion in the interferometer. The utilization of these two functions brings two major improvements to previous implementations of the MSI method. The paper details the steps to obtain the functions g and h, and represents the CMSI in a matrix formulation that enables to implement easily this method in LabVIEW by using parallel programming with multi-cores.

  15. Master-slave interferometry for parallel spectral domain interferometry sensing and versatile 3D optical coherence tomography.

    PubMed

    Podoleanu, Adrian Gh; Bradu, Adrian

    2013-08-12

    Conventional spectral domain interferometry (SDI) methods suffer from the need of data linearization. When applied to optical coherence tomography (OCT), conventional SDI methods are limited in their 3D capability, as they cannot deliver direct en-face cuts. Here we introduce a novel SDI method, which eliminates these disadvantages. We denote this method as Master - Slave Interferometry (MSI), because a signal is acquired by a slave interferometer for an optical path difference (OPD) value determined by a master interferometer. The MSI method radically changes the main building block of an SDI sensor and of a spectral domain OCT set-up. The serially provided signal in conventional technology is replaced by multiple signals, a signal for each OPD point in the object investigated. This opens novel avenues in parallel sensing and in parallelization of signal processing in 3D-OCT, with applications in high- resolution medical imaging and microscopy investigation of biosamples. Eliminating the need of linearization leads to lower cost OCT systems and opens potential avenues in increasing the speed of production of en-face OCT images in comparison with conventional SDI.

  16. Laser Development for Gravitational-Wave Interferometry in Space

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Camp, Jordan

    2012-01-01

    We are reporting on our development work on laser (master oscillator) and optical amplifier systems for gravitational-wave interferometry in space. Our system is based on the mature, wave-guided optics technologies, which have advantages over bulk, crystal-based, free-space optics. We are investing in a new type of compact, low-noise master oscillator, called the planar-waveguide external cavity diode laser. We made measurements, including those of noise, and performed space-qualification tests.

  17. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    PubMed

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  18. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

    PubMed

    Kaswin, Godefroy; Rousseau, Antoine; Mgarrech, Mohamed; Barreau, Emmanuel; Labetoulle, Marc

    2014-04-01

    To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Paris, France. Evaluation of a diagnostic device. One eye of consecutive patients scheduled for cataract surgery was measured. Biometry was performed with the new biometer and the reference biometer. Comparisons were performed for AL, average K at 2.4 mm, ACD, IOL power calculations with the Haigis and SRK/T formulas, and postoperative predictability of the devices. A P value less than 0.05 was statistically significant. The study enrolled 50 patients (mean age 72.6 years±4.2 SEM). There was a good correlation between biometers for AL, K, and ACD measurements (r=0.999, r=0.933, and r=0.701, respectively) and between IOL power calculation with the Haigis formula (r=0.972) and the SRK/T formula (r=0.981). The mean absolute error (MAE) in IOL power prediction was 0.42±0.08 diopter (D) with the new biometer and 0.44±0.08 D with the reference biometer. The MAE was 0.20 D with the Haigis formula and 0.19 with the SRK/T formula (P=.36). The new PCI biometer provided valid measurements compared with the current gold standard, indicating that the new device can be used for IOL power calculations for routine cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. A Comparative Study to Assess the Predictability of Different IOL Power Calculation Formulas in Eyes of Short and Long Axial Length.

    PubMed

    Doshi, Dharmil; Limdi, Purvi; Parekh, Nilesh; Gohil, Neepa

    2017-01-01

    Accurate Intraocular Lens (IOL) power calculation in cataract surgery is very important for providing postoperative precise vision. Selection of most appropriate formula is difficult in high myopic and hypermetropic patients. To investigate the predictability of different IOL (Intra Ocular Lens) power calculation formulae in eyes with short and long Axial Length (AL) and to find out most accurate IOL power calculation formula in both groups. A prospective study was conducted on 80 consecutive patients who underwent phacoemulsification with monofocal IOL implantation after obtaining an informed and written consent. Preoperative keratometry was done by IOL Master. Axial length and anterior chamber depth was measured using A-scan machine ECHORULE 2 (BIOMEDIX). Patients were divided into two groups based on AL. (40 in each group). Group A with AL<22 mm and Group B with AL>24.5 mm. The IOL power calculation in each group was done by Haigis, Hoffer Q, Holladay-I, SRK/T formulae using the software of ECHORULE 2. The actual postoperative Spherical Equivalent (SE), Estimation error (E) and Absolute Error (AE) were calculated at one and half months and were used in data analysis. The predictive accuracy of each formula in each group was analyzed by comparing the Absolute Error (AE). The Kruskal Wallis test was used to compare differences in the (AE) of the formulae. A statistically significant difference was defined as p-value<0.05. In Group A, Hoffer Q, Holladay 1 and SRK/T formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm and accuracy of these three formulae was significantly higher than Haigis formula. Whereas in Group B, Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL more than 24.5 mm. Hoffer Q, Holladay 1 and SRK/T formulae were showing significantly higher accuracy than Haigis formula in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm. In eyes with AL more than 24.5 mm Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate.

  20. A Comparative Study to Assess the Predictability of Different IOL Power Calculation Formulas in Eyes of Short and Long Axial Length

    PubMed Central

    Limdi, Purvi; Parekh, Nilesh; Gohil, Neepa

    2017-01-01

    Introduction Accurate Intraocular Lens (IOL) power calculation in cataract surgery is very important for providing postoperative precise vision. Selection of most appropriate formula is difficult in high myopic and hypermetropic patients. Aim To investigate the predictability of different IOL (Intra Ocular Lens) power calculation formulae in eyes with short and long Axial Length (AL) and to find out most accurate IOL power calculation formula in both groups. Materials and Methods A prospective study was conducted on 80 consecutive patients who underwent phacoemulsification with monofocal IOL implantation after obtaining an informed and written consent. Preoperative keratometry was done by IOL Master. Axial length and anterior chamber depth was measured using A-scan machine ECHORULE 2 (BIOMEDIX). Patients were divided into two groups based on AL. (40 in each group). Group A with AL<22 mm and Group B with AL>24.5 mm. The IOL power calculation in each group was done by Haigis, Hoffer Q, Holladay-I, SRK/T formulae using the software of ECHORULE 2. The actual postoperative Spherical Equivalent (SE), Estimation error (E) and Absolute Error (AE) were calculated at one and half months and were used in data analysis. The predictive accuracy of each formula in each group was analyzed by comparing the Absolute Error (AE). The Kruskal Wallis test was used to compare differences in the (AE) of the formulae. A statistically significant difference was defined as p-value<0.05. Results In Group A, Hoffer Q, Holladay 1 and SRK/T formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm and accuracy of these three formulae was significantly higher than Haigis formula. Whereas in Group B, Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL more than 24.5 mm. Conclusion Hoffer Q, Holladay 1 and SRK/T formulae were showing significantly higher accuracy than Haigis formula in predicting the postoperative refraction after cataract surgery (IOL power calculation) in eyes with AL less than 22.0 mm. In eyes with AL more than 24.5 mm Hoffer Q, Holladay 1, SRK/T and Haigis formulae were equally accurate. PMID:28273986

  1. [Can the scattering of differences from the target refraction be avoided?].

    PubMed

    Janknecht, P

    2008-10-01

    We wanted to check how the stochastic error is affected by two lens formulae. The power of the intraocular lens was calculated using the SRK-II formula and the Haigis formula after eye length measurement with ultrasound and the IOL Master. Both lens formulae were partially derived and Gauss error analysis was used for examination of the propagated error. 61 patients with a mean age of 73.8 years were analysed. The postoperative refraction differed from the calculated refraction after ultrasound biometry using the SRK-II formula by 0.05 D (-1.56 to + 1.31, S. D.: 0.59 D; 92 % within +/- 1.0 D), after IOL Master biometry using the SRK-II formula by -0.15 D (-1.18 to + 1.25, S. D.: 0.52 D; 97 % within +/- 1.0 D), and after IOL Master biometry using the Haigis formula by -0.11 D (-1.14 to + 1.14, S. D.: 0.48 D; 95 % within +/- 1.0 D). The results did not differ from one another. The propagated error of the Haigis formula can be calculated according to DeltaP = square root (deltaL x (-4.206))(2) + (deltaVK x 0.9496)(2) + (DeltaDC x (-1.4950))(2). (DeltaL: error measuring axial length, DeltaVK error measuring anterior chamber depth, DeltaDC error measuring corneal power), the propagated error of the SRK-II formula according to DeltaP = square root (DeltaL x (-2.5))(2) + (DeltaDC x (-0.9))(2). The propagated error of the Haigis formula is always larger than the propagated error of the SRK-II formula. Scattering of the postoperative difference from the expected refraction cannot be avoided completely. It is possible to limit the systematic error by developing complicated formulae like the Haigis formula. However, increasing the number of parameters which need to be measured increases the dispersion of the calculated postoperative refraction. A compromise has to be found, and therefore the SRK-II formula is not outdated.

  2. Using a micro-molding process to fabricate polymeric wavelength filters

    NASA Astrophysics Data System (ADS)

    Chuang, Wei-Ching; Lee, An-Chen; Ho, Chi-Ting

    2008-08-01

    A procedure for fabricating a high aspect ratio periodic structure on a UV polymer at submicron order using holographic interferometry and molding processes is described. First, holographic interferometry using a He-Cd (325 nm) laser was used to create the master of the periodic line structure on an i-line sub-micron positive photoresist film. A 20 nm nickel thin film was then sputtered on the photoresist. The final line pattern on a UV polymer was obtained from casting against the master mold. Finally, a SU8 polymer was spun on the polymer grating to form a planar waveguide or a channel waveguide. The measurement results show that the waveguide length could be reduced for the waveguide having gratings with a high aspect ratio.

  3. Anterior chamber depth studies.

    PubMed

    Hoffer, Kenneth J; Savini, Giacomo

    2015-09-01

    To compare the anterior chamber depth (ACD; corneal epithelium to lens) using 3 modalities and compare the change 1 day and 3 months postoperatively. Private practice, Santa Monica, California, USA. Nonrandomized prospective series. The mean optical pachymetry and immersion ultrasound (US) of the ACD and partial coherence interferometry (PCI) were measured. Optical pachymetry ACD was measured in 675 eyes postoperatively at 1 day and 3 months. The optical pachymetry ACD in 492 eyes was 3.17 mm ± 0.42 (SD); by immersion US, it was 2.99 ± 0.51 mm (0.18 mm deeper; P < .0001). In 178 eyes, the optical pachymetry ACD was 3.23 ± 0.45 mm; the PCI was 3.19 ± 0.48 mm (0.04 mm deeper), which was not statistically different (P > .05). In 675 eyes, optical pachymetry ACD preoperatively was 3.19 ± 0.40 mm. The postoperative 1-day optical pachymetry ACD was 4.35 ± 0.35 mm with a mean refractive error of -0.30 diopter (D); the final 3-month optical pachymetry ACD was 4.47 ± 0.31 mm, with a mean refractive error of -0.07 D (P < .0001). This is a mean intraocular lens (IOL) position shift of +0.12 mm posteriorly; the +0.23 D change represents a ratio of 1.92 D/mm of IOL axial movement. The PCI ACD was comparable with optical pachymetry, but careful immersion US led to a 0.18 mm shorter ACD reading that cannot be corrected by sound velocity. The posterior capsule contracted and moved the IOL posteriorly 0.12 mm, resulting in 0.23 D hyperopic shift. Dr. Hoffer owns the registered trademark name "Hoffer(®)" and receives royalties for its commercial use from Alcon Laboratories, Inc., Appasamy Associates, Carl Zeiss Meditec AG, DGH Technology, Inc., Ellex iScience, Inc., Haag-Streit AG, Nidek Co., Ltd., Tomey Corp., Topcon Medical Systems, Inc., and Ziemer USA, Inc., as well as royalties from Slack, Inc. for the textbook IOL Power. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: Influence of pupil size, decentration, and rotation.

    PubMed

    Kim, Min-Ji; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2015-10-01

    To evaluate the effect of pupil size, degree of intraocular lens (IOL) decentration, and rotation of 4 aspheric toric IOLs on the image quality. Department of Ophthalmology, Seoul St. Mary's Hospital, Seoul, South Korea. Experimental study. Four aspheric toric intraocular lenses (IOLs)-the Precizon (transitional conic toric IOL), AT Torbi 709M (bitoric IOL), SN6AT4 (posterior toric surface IOL), and ZCT225 (anterior toric surface IOL)-were evaluated using the optical bench metrology system. Measurements included changes in spherical aberrations, relative spherical equivalent (SE), and image quality at different pupil diameters and image quality degradation due to decentration and rotation of the IOLs. Change in relative SE with pupil size in aberration-free toric IOLs (transitional conic toric and bitoric IOLs) was greater than in negatively aspheric toric IOLs (posterior toric surface and anterior toric surface IOLs). In contrast, the aberration-free IOLs showed higher contrast than the negatively aspheric IOLs. When IOLs were decentered by 1.0 mm, the contrast reduction rates at 17.6 cycles per degree for the transitional conic toric IOL, bitoric IOL, posterior toric surface IOL, and anterior toric surface IOL were 5.1%, 3.1%, 12.2%, and 15.8%, respectively. Rotation-induced deterioration of contrast to 0.5 required a much higher rotation for the transitional conic toric IOL than for the other 3 IOLs. The transitional conic toric IOL and bitoric IOL provided superior image quality despite pupil size changes and the presence of decentration. The transitional conic toric IOL demonstrated maximum rotation tolerance compared with the other IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Identification of Two myo-Inositol Transporter Genes of Bacillus subtilis

    PubMed Central

    Yoshida, Ken-Ichi; Yamamoto, Yoshiyuki; Omae, Kaoru; Yamamoto, Mami; Fujita, Yasutaro

    2002-01-01

    Among hundreds of mutants constructed systematically by the Japanese groups participating in the functional analysis of the Bacillus subtilis genome project, we found that a mutant with inactivation of iolT (ydjK) exhibited a growth defect on myo-inositol as the sole carbon source. The putative product of iolT exhibits significant similarity with many bacterial sugar transporters in the databases. In B. subtilis, the iolABCDEFGHIJ and iolRS operons are known to be involved in inositol utilization, and its transcription is regulated by the IolR repressor and induced by inositol. Among the iol genes, iolF was predicted to encode an inositol transporter. Inactivation of iolF alone did not cause such an obvious growth defect on inositol as the iolT inactivation, while simultaneous inactivation of the two genes led to a more severe defect than the single iolT inactivation. Determination of inositol uptake by the mutants revealed that iolT inactivation almost completely abolished uptake, but uptake by IolF itself was slightly detectable. These results, as well as the Km and Vmax values for the IolT and IolF inositol transporters, indicated that iolT and iolF encode major and minor inositol transporters, respectively. Northern and primer extension analyses of iolT transcription revealed that the gene is monocistronically transcribed from a promoter likely recognized by ςsgr;A RNA polymerase and negatively regulated by IolR as well. The interaction between IolR and the iolT promoter region was analyzed by means of gel retardation and DNase I footprinting experiments, it being suggested that the mode of interaction is quite similar to that found for the promoter regions of the iol divergon. PMID:11807058

  6. [To exercise caution in developing intraocular lens exchange].

    PubMed

    Song, X D; Wang, X Z; Qian, J

    2018-05-11

    Nowadays cataract extraction combined intraocular lens (IOL) implantation has become the conventional treatment for cataract. Numbers of IOL exchange after cataract extraction combined IOL implantation have been increasing in recent years. As a non-routine surgery, IOL exchange is normally combined with other surgeries and accompanied by some complications to various extents. Is IOL exchange necessary for all abnomal IOLs? Can IOL exchange be avoided? How to avoid IOL exchange? The purpose of this article is to stress the importance of indication of IOL exchange and how to avoid IOL exchange. (Chin J Ophthalmol, 2018, 54: 324-327) .

  7. Comparative analysis of visual outcomes with 4 intraocular lenses: Monofocal, multifocal, and extended range of vision.

    PubMed

    Pedrotti, Emilio; Carones, Francesco; Aiello, Francesco; Mastropasqua, Rodolfo; Bruni, Enrico; Bonacci, Erika; Talli, Pietro; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2018-02-01

    To compare the visual acuity, refractive outcomes, and quality of vision in patients with bilateral implantation of 4 intraocular lenses (IOLs). Department of Neurosciences, Biomedicine and Movement Sciences, Eye Clinic, University of Verona, Verona, and Carones Ophthalmology Center, Milano, Italy. Prospective case series. The study included patients who had bilateral cataract surgery with the implantation of 1 of 4 IOLs as follows: Tecnis 1-piece monofocal (monofocal IOL), Tecnis Symfony extended range of vision (extended-range-of-vision IOL), Restor +2.5 diopter (D) (+2.5 D multifocal IOL), and Restor +3.0 D (+3.0 D multifocal IOL). Visual acuity, refractive outcome, defocus curve, objective optical quality, contrast sensitivity, spectacle independence, and glare perception were evaluated 6 months after surgery. The study comprised 185 patients. The extended-range-of-vision IOL (55 patients) showed better distance visual outcomes than the monofocal IOL (30 patients) and high-addition apodized diffractive-refractive multifocal IOLs (P ≤ .002). The +3.0 D multifocal IOL (50 patients) showed the best near visual outcomes (P < .001). The +2.5 D multifocal IOL (50 patients) and extended-range-of-vision IOL provided significantly better intermediate visual outcomes than the other 2 IOLs, with significantly better vision for a defocus level of -1.5 D (P < .001). Better spectacle independence was shown for the +2.5 D multifocal IOL and extended-range-of-vision IOL (P < .001). The extended-range-of-vision IOL and +2.5 D multifocal IOL provided significantly better intermediate visual restoration after cataract surgery than the monofocal IOL and +3.0 D multifocal IOL, with significantly better quality of vision with the extended-range-of-vision IOL. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Intraocular lens power calculations for cataract surgery after phototherapeutic keratectomy in granular corneal dystrophy type 2.

    PubMed

    Jung, Se Hwan; Han, Kyung Eun; Sgrignoli, Bradford; Kim, Tae-Im; Lee, Hyung Keun; Kim, Eung Kweon

    2012-10-01

    To investigate the predictability of various intraocular lens (IOL) power calculation methods in granular corneal dystrophy type 2 (GCD2) with prior phototherapeutic keratectomy (PTK) and to suggest the more predictable IOL power calculation method. Medical records of 20 eyes from 16 patients with GCD2, all having undergone cataract surgery after PTK, were retrospectively evaluated. Postoperative cataract refractive errors were compared with target diopters (D) using IOL power calculation methods as follows: 1) myopic and 2) hyperopic Haigis-L formula in IOLMaster (Carl Zeiss Meditec); 3) SRK/T formula using 4.5-mm zone Holladay equivalent keratometry readings (EKRs) (single-K Holladay EKRs method); 4) central keratometry power of true net power map in the Pentacam system (Oculus Optikgeräte GmbH); and 5) clinical history, Aramberri double-K, and double-K Holladay EKRs methods. Topographic status of corneal curvature after PTK was evaluated. Fourteen (70%) of 20 eyes showed central island formation after PTK. When central island was present, the mean absolute error (MAE) using the hyperopic Haigis-L formula was 0.25±0.15 D. When central island was not present, the myopic Haigis-L formula showed MAE of 0.33±0.16 D. When central island formation and IOLMaster keratometry underestimation were present, the hyperopic Haigis-L formula showed the least MAE of 0.26±0.08 D when switching the IOL-Master keratometry values equal to 4.5-mm zone Holladay EKRs. In planning for cataract surgery after PTK in GCD2, topographic analysis for central island formation is necessary. With or without central island formation, the hyperopic or myopic Haigis-L formula can be applied. When IOLMaster keratometry shows underestimation, the Haigis-L formula using 4.5-mm zone Holladay EKRs can be considered. Copyright 2012, SLACK Incorporated.

  9. Bacillus subtilis IolQ (DegA) is a transcriptional repressor of iolX encoding NAD+-dependent scyllo-inositol dehydrogenase.

    PubMed

    Kang, Dong-Min; Michon, Christophe; Morinaga, Tetsuro; Tanaka, Kosei; Takenaka, Shinji; Ishikawa, Shu; Yoshida, Ken-Ichi

    2017-07-11

    Bacillus subtilis is able to utilize at least three inositol stereoisomers as carbon sources, myo-, scyllo-, and D-chiro-inositol (MI, SI, and DCI, respectively). NAD + -dependent SI dehydrogenase responsible for SI catabolism is encoded by iolX. Even in the absence of functional iolX, the presence of SI or MI in the growth medium was found to induce the transcription of iolX through an unknown mechanism. Immediately upstream of iolX, there is an operon that encodes two genes, yisR and iolQ (formerly known as degA), each of which could encode a transcriptional regulator. Here we performed an inactivation analysis of yisR and iolQ and found that iolQ encodes a repressor of the iolX transcription. The coding sequence of iolQ was expressed in Escherichia coli and the gene product was purified as a His-tagged fusion protein, which bound to two sites within the iolX promoter region in vitro. IolQ is a transcriptional repressor of iolX. Genetic evidences allowed us to speculate that SI and MI might possibly be the intracellular inducers, however they failed to antagonize DNA binding of IolQ in in vitro experiments.

  10. Distance vision after bilateral implantation of AcrySof toric intraocular lenses: a randomized, controlled, prospective trial

    PubMed Central

    Zhang, Jin-Song; Zhao, Jiang-Yue; Sun, Qi; Ma, Li-Wei

    2011-01-01

    AIM To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL. METHODS This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL. IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients. Assessments included monocular and binocular distance vision, with and without best correction. Patients also completed surveys about their distance vision. RESULTS Preoperatively, the two study groups were similar in age, in distance visual acuity, and in the magnitude of corneal astigmatism. At 6 months postoperative, binocular uncorrected distance vision was 0.06±0.14 logMAR in the AcrySof toric IOL group, significantly better than the 0.14±0.11 logMAR in the spherical IOL group (P<0.05). For eyes with emmetropia as a target, the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes). No patients in the emmetropia/toric IOL group used distance glasses, as compared to 52% of patients in the emmetropia/spherical IOL group. All patients were satisfied or highly satisfied. Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05). CONCLUSION Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism. PMID:22553636

  11. Toxicity of iron overload and iron overload reduction in the setting of hematopoietic stem cell transplantation for hematologic malignancies.

    PubMed

    Leitch, Heather A; Fibach, Eitan; Rachmilewitz, Eliezer

    2017-05-01

    Iron is an essential element for key cellular metabolic processes. However, transfusional iron overload (IOL) may result in significant cellular toxicity. IOL occurs in transfusion dependent hematologic malignancies (HM), may lead to pathological clinical outcomes, and IOL reduction may improve outcomes. In hematopoietic stem cell transplantation (SCT) for HM, IOL may have clinical importance; endpoints examined regarding an impact of IOL and IOL reduction include transplant-related mortality, organ function, infection, relapse risk, and survival. Here we review the clinical consequences of IOL and effects of IOL reduction before, during and following SCT for HM. IOL pathophysiology is discussed as well as available tests for IOL quantification including transfusion history, serum ferritin level, transferrin saturation, hepcidin, labile plasma iron and other parameters of iron-catalyzed oxygen free radicals, and organ IOL by imaging. Data-based recommendations for IOL measurement, monitoring and reduction before, during and following SCT for HM are made. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Image quality comparison of two multifocal IOLs: influence of the pupil.

    PubMed

    García-Domene, Mari Carmen; Felipe, Adelina; Peris-Martínez, Cristina; Navea, Amparo; Artigas, Jose M; Pons, Álvaro M

    2015-04-01

    To evaluate the effect of pupil size on image quality of a sectorial multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), and the Acri.LISA IOL (Carl Zeiss Meditec, Jena, Germany). The authors measured the MTFs of the Lentis Mplus LS-312 IOL and the Acri.LISA 366D IOL with three different sizes of pupil diameters: 3, 4, and 5 mm. The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd., Oxford, UK) by using fast Fourier-transform techniques. In distance focus, the image quality provided by the Lentis Mplus IOL was better than that of the Acri. LISA IOL with all pupil diameters. In near focus, the MTF of the Acri.LISA IOL was better with a 3-mm pupil, but poor with larger pupils. The aberration effect was equal in both IOLs in distance focus, but in near focus and with a 3-mm pupil, the Acri.LISA IOL was less affected by the aberration than the Lentis Mplus IOL. The Lentis Mplus IOL provides better distance image quality than the Acri.LISA IOL, whereas the near image quality of the Acri.LISA IOL is better with small-pupil diameter. The sectorial design makes this IOL more suitable for patients with a pupil diameter greater than 3 mm. Copyright 2015, SLACK Incorporated.

  13. Changes in blood pressure and sleep duration in patients with blue light-blocking/yellow-tinted intraocular lens (CHUKYO study).

    PubMed

    Ichikawa, Kazuo

    2014-07-01

    Blood pressure and sleep duration may be influenced by retinal light exposure. Cataracts may exert such an influence by decreasing the transparency of the crystalline lens. A large-scale clinical study was conducted to examine changes in blood pressure and sleep duration after intraocular lens (IOL) implantation during cataract surgery and to investigate how different types of IOL influence the degree of these effects. Using a questionnaire, we collected information, including blood pressure measurement and sleep duration, from 1367 patients (1367 eyes) before IOL implantation, 1 week after IOL implantation and 1 month after IOL implantation. Systolic and diastolic blood pressures were significantly decreased in the total patient group after implantation. The decrease in systolic blood pressure 1 month after implantation was significantly more in patients who received a yellow-tinted IOL than it was in those who received an ultraviolet (UV) light-filtering IOL. The post-implantation sleep duration, including naps, became shorter in patients who had slept too much and became longer in those who had slept too little before IOL implantation. Our observations suggest that a yellow-tinted IOL is better for patients with high blood pressure than a UV light-filtering IOL. Furthermore, the yellow-tinted IOL is as good as the UV light-filtering IOL for improving sleep duration. A pale yellow-tinted IOL is likely to be superior to a moderate yellow-tinted IOL in terms of allowing patients to discriminate different colors. Thus, the pale yellow-tinted IOL appears to be better for patients than the UV light-filtering IOL and the moderate yellow-tinted IOL.

  14. Refractive outcomes after multifocal intraocular lens exchange.

    PubMed

    Kim, Eric J; Sajjad, Ahmar; Montes de Oca, Ildamaris; Koch, Douglas D; Wang, Li; Weikert, Mitchell P; Al-Mohtaseb, Zaina N

    2017-06-01

    To evaluate the refractive outcomes after multifocal intraocular lens (IOL) exchange. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. Patients had multifocal IOL explantation followed by IOL implantation. Outcome measures included type of IOL, surgical indication, corrected distance visual acuity (CDVA), and refractive prediction error. The study comprised 29 patients (35 eyes). The types of IOLs implanted after multifocal IOL explantation included in-the-bag IOLs (74%), iris-sutured IOLs (6%), sulcus-fixated IOLs with optic capture (9%), sulcus-fixated IOLs without optic capture (9%), and anterior chamber IOLs (3%). The surgical indication for exchange included blurred vision (60%), photic phenomena (57%), photophobia (9%), loss of contrast sensitivity (3%), and multiple complaints (29%). The CDVA was 20/40 or better in 94% of eyes before the exchange and 100% of eyes after the exchange (P = .12). The mean refractive prediction error significantly decreased from 0.22 ± 0.81 diopter (D) before the exchange to -0.09 ± 0.53 D after the exchange (P < .05). The median absolute refractive prediction error significantly decreased from 0.43 D before the exchange to 0.23 D after the exchange (P < .05). Multifocal IOL exchange can be performed safely with good visual outcomes using different types of IOLs. A lower refractive prediction error and a higher likelihood of 20/40 or better vision can be achieved with the implantation of the second IOL compared with the original multifocal IOL, regardless of the final IOL position. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Post implantation adjustable intraocular lenses.

    PubMed

    Schwartz, D M; Jethmalani, J M; Sandstedt, C A; Kornfield, J A; Grubbs, R H

    2001-06-01

    To eliminate persistent refractive errors after cataract and phakic IOL surgery, photosensitive silicone IOLs have been developed. These IOL formulations enable precise laser adjustment of IOL power to correct spherical and toric errors post-operatively, after wound and IOL stabilization. Initial experience with these laser adjustable IOLs indicate excellent biocompatability and adjustability of more than five diopters.

  16. Pigment dispersion glaucoma induced by the chafing effect of intraocular lens haptics in Asian eyes.

    PubMed

    Hong, Ying; Sun, Yan-Xiu; Qi, Hong; Zhou, Ji-Chao; Hao, Yan-Sheng

    2013-03-01

    To study the possible mechanism and treatment for pigment dispersion glaucoma (PDG) caused by single-piece acrylic (SPA) intraocular lens (IOL) ciliary sulcus fixation in Asian eyes. Patients referred for PDG caused by SPA IOL ciliary sulcus fixation to our hospital from April 2005 to June 2011 were included. The patients' general information, IOL type, interval between initial surgery and PDG occurrence, examination findings, antiglaucoma medicine regimen and surgical interventions were recorded. In total, six eyes from five Chinese patients were included in this study. The intraocular pressure (IOP) increased 19-30 days after cataract surgery and was not satisfactorily controlled with antiglaucoma medication. Dense pigmentation was deposited on the IOLs and on the anterior chamber angle. IOL haptic chafing was noted on the rear iris surface. IOL repositioning in the capsular bag was performed in three eyes and was combined with trabeculectomy in two eyes with progressive glaucoma. An IOL exchange with three-piece IOL ciliary sulcus fixation was performed in the other three eyes. Scanning electron microscopy of the explanted IOLs demonstrated a rough edge on the IOL haptics. SPA IOLs were not suitable for ciliary sulcus fixation. The chafing effect of the IOL haptics on the posterior iris pigment epithelium could induce PDG in Asian eyes. IOLs should be positioned in the capsular bag or a three-piece IOL should be used instead.

  17. Light scattering and light transmittance of cadaver eye-explanted intraocular lenses of different materials.

    PubMed

    Morris, Caleb; Werner, Liliana; Barra, Daniel; Liu, Erica; Stallings, Shannon; Floyd, Anne

    2014-01-01

    To evaluate light scattering and light transmittance in cadaver eye-explanted intraocular lenses (IOLs) manufactured from different materials. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Forty-nine pseudophakic cadaver eyes were selected according to IOL material/type and implantation duration, and the IOLs were explanted. Hydrophobic acrylic, hydrophilic acrylic, poly(methyl methacrylate) (PMMA), and silicone IOLs were included. Gross and light microscopy was performed for all IOLs. Light scattering was measured with an EAS 1000 Scheimpflug camera, and light transmittance was assessed using a Lambda 35 UV/Vis spectrophotometer (single-beam configuration with an RSA PE-20 integrating sphere). Analyses were performed at room temperature in the hydrated state and compared with analyses of controls. The highest levels of surface light scattering were measured for 3-piece hydrophobic acrylic, which was also the IOL type with the longest implantation duration among the Acrysof hydrophobic acrylic IOLs. Hydrophilic acrylic, PMMA, and silicone IOLs exhibited relatively low light-scattering levels. The lowest light-scattering levels were observed with PMMA IOLs (1-piece looped and 3-piece) and plate silicone IOLs, which represent the IOL types with the longest implantation duration in this series. Light transmittance values measured for all IOL types appeared to be similar to the values of the corresponding control IOLs. The phenomenon of surface light scattering (nanoglistenings) is more particularly related to hydrophobic acrylic IOLs and increases with implantation time. No significant effect of surface light scattering on IOL light transmittance was found. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Optical performance of toric intraocular lenses in the presence of decentration.

    PubMed

    Zhang, Bin; Ma, Jin-Xue; Liu, Dan-Yan; Du, Ying-Hua; Guo, Cong-Rong; Cui, Yue-Xian

    2015-01-01

    To evaluate the optical performance of toric intraocular lenses (IOLs) after decentration and with different pupil diameters, but with the IOL astigmatic axis aligned. Optical performances of toric T5 and SN60AT spherical IOLs after decentration were tested on a theoretical pseudophakic model eye based on the Hwey-Lan Liou schematic eye using the Zemax ray-tracing program. Changes in optical performance were analyzed in model eyes with 3-mm, 4-mm, and 5-mm pupil diameters and decentered from 0.25 mm to 0.75 mm with an interval of 5° at the meridian direction from 0° to 90°. The ratio of the modulation transfer function (MTF) between a decentered and a centered IOL (MTFDecentration/MTFCentration) was calculated to analyze the decrease in optical performance. Optical performance of the toric IOL remained unchanged when IOLs were decentered in any meridian direction. The MTFs of the two IOLs decreased, whereas optical performance remained equivalent after decentration. The MTFDecentration/MTFCentration ratios of the IOLs at a decentration from 0.25 mm to 0.75 mm were comparable in the toric and SN60AT IOLs. After decentration, MTF decreased further, with the MTF of the toric IOL being slightly lower than that of the SN60AT IOL. Imaging qualities of the two IOLs decreased when the pupil diameter and the degree of decentration increased, but the decrease was similar in the toric and spherical IOLs. Toric IOLs were comparable to spherical IOLs in terms of tolerance to decentration at the correct axial position.

  19. Optical performance of toric intraocular lenses in the presence of decentration

    PubMed Central

    Zhang, Bin; Ma, Jin-Xue; Liu, Dan-Yan; Du, Ying-Hua; Guo, Cong-Rong; Cui, Yue-Xian

    2015-01-01

    AIM To evaluate the optical performance of toric intraocular lenses (IOLs) after decentration and with different pupil diameters, but with the IOL astigmatic axis aligned. METHODS Optical performances of toric T5 and SN60AT spherical IOLs after decentration were tested on a theoretical pseudophakic model eye based on the Hwey-Lan Liou schematic eye using the Zemax ray-tracing program. Changes in optical performance were analyzed in model eyes with 3-mm, 4-mm, and 5-mm pupil diameters and decentered from 0.25 mm to 0.75 mm with an interval of 5° at the meridian direction from 0° to 90°. The ratio of the modulation transfer function (MTF) between a decentered and a centered IOL (MTFDecentration/MTFCentration) was calculated to analyze the decrease in optical performance. RESULTS Optical performance of the toric IOL remained unchanged when IOLs were decentered in any meridian direction. The MTFs of the two IOLs decreased, whereas optical performance remained equivalent after decentration. The MTFDecentration/MTFCentration ratios of the IOLs at a decentration from 0.25 mm to 0.75 mm were comparable in the toric and SN60AT IOLs. After decentration, MTF decreased further, with the MTF of the toric IOL being slightly lower than that of the SN60AT IOL. Imaging qualities of the two IOLs decreased when the pupil diameter and the degree of decentration increased, but the decrease was similar in the toric and spherical IOLs. CONCLUSIONS Toric IOLs were comparable to spherical IOLs in terms of tolerance to decentration at the correct axial position. PMID:26309871

  20. Biometry and spectral domain optical coherence tomography parameters in children with large cupping.

    PubMed

    Jung, Jong Jin; Baek, Seung-Hee; Kim, Ungsoo Samuel

    2013-09-01

    The purpose of this study is to investigate optic nerve head using spectral domain optical coherence tomography (SD-OCT) in children with large cupping. 111 eyes (4-10 years) were divided into three groups according to the cup to disc ratio: group 1, ≤0.3; group 2, 0.4-0.6; and group 3, ≥0.7. The rim area, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume were investigated using SD-OCT (Cirrus HD-OCT, Carl Zeiss, Jena, Germany), and the axial length and anterior chamber depth (ACD) were measured by IOL master (IOL master 500, Carl Zeiss, Jena, Germany). Next, we compared ocular biometry and SD-OCT between the three groups. The mean age of group 1 was 6.48 ± 1.42 years, 7.00 ± 1.75 years in group 2, and 6.63 ± 1.82 years in group 3 (p = 0.370). A significant difference was seen in the spherical equivalent between the groups (p = 0.001). Group 2 had the most myopic refractive errors. As the cup to disc ratio increases, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume increase significantly. When the results of ocular biometry and SD-OCT are adjusted for axial length, only disc area showed a significant correlation with cup to disc ratio (ACD: p = 0.473, rim area: p = 0.639, disc area: p = 0.005, and cup volume: p = 0.325). Axial length is the key factor determining disc size, which in turn is important for determining cup to disc ratio. Normal children with large cupping should be examined for axial length, myopic refractive errors, and disc size.

  1. Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study

    PubMed Central

    Oshika, T.; Nagata, T.; Ishii, Y.

    1998-01-01

    AIMS—To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule.
METHODS—Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between the anterior/posterior capsules and IOL optic was tested, and the capsule was examined histologically.
RESULTS—The mean adhesive force to the collagen sheet was 1697 (SD 286) mg for acrylic foldable, 583 (49) mg for PMMA, and 0 mg for silicone IOLs (p=0.0003, Kruskal-Wallis test). Scores (0-5) of adhesion between rabbit anterior capsule and IOL optic were 4.50 (0.55) for acrylic foldable, 3.20 (0.84) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.004). Scores between rabbit posterior capsule and IOL optic displayed a similar tendency; 4.50 (0.84) for acrylic foldable, 3.00 (1.00) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.021). Histological observation indicated that the edge of IOL optic suppressed the migration of lens epithelial cells towards the centre of the posterior capsule. This inhibitory effect was most pronounced with acrylic foldable IOL and least with silicone IOL.
CONCLUSIONS—The acrylic foldable IOL adhered to the lens capsule more than the PMMA IOL, and the silicone IOL showed no adhesiveness. These differences seem to play a role in preventing lens epithelial cells from migrating and forming posterior capsule opacification.

 Keywords: intraocular lens; lens capsule; posterior capsule opacification; adhesion PMID:9713064

  2. Evaluating and defining the sharpness of intraocular lenses: microedge structure of commercially available square-edged hydrophobic lenses.

    PubMed

    Werner, Liliana; Müller, Matthias; Tetz, Manfred

    2008-02-01

    To evaluate the microstructure of the edges of currently available square-edged hydrophobic intraocular lenses (IOLs) in terms of their deviation from an ideal square. Berlin Eye Research Institute, Berlin, Germany. Sixteen designs of hydrophobic acrylic or silicone IOLs were studied. For each design, a +20.0 diopter (D) IOL and a +0.0 D IOL (or the lowest available plus dioptric power) were evaluated. The IOL edge was imaged under high-magnification scanning electron microscopy using a standardized technique. The area above the lateral-posterior edge, representing the deviation from a perfect square, was measured in square microns using reference circles of 40 microm and 60 microm of radius and the AutoCAD LT 2000 system (Autodesk). The IOLs were compared with an experimental square-edged poly(methyl methacrylate) (PMMA) IOL (reference IOL) with an edge design that effectively stopped lens epithelial cell growth in culture in a preliminary study. Two round-edged silicone IOLs were used as controls. The hydrophobic IOLs used, labeled as square-edged IOLs, had an area of deviation from a perfect square ranging from 4.8 to 338.4 microm(2) (40 microm radius reference circle) and from 0.2 to 524.4 microm(2) (60 microm radius circle). The deviation area for the square-edged PMMA IOL was 34.0 microm(2) with a 40 microm radius circle and 37.5 microm(2) with a 60 microm radius circle. The respective values for the +20.0 D control silicone IOL were 729.3 microm(2) and 1525.3 microm(2) and for the +0.0 D control silicone IOL, 727.3 microm(2) and 1512.7 microm(2). Seven silicone IOLs of 5 designs had area values that were close to those of the reference square-edged PMMA IOL. Several differences in edge finishing between the IOLs analyzed were also observed. There was a large variation in the deviation area from a perfect square as well as in the edge finishing, not only between different IOL designs but also between different powers of the same design. Clinically, factors such as the shrink-wrapping of the IOL by the capsule may even out or modify the influence of these variations in terms of preventing posterior capsule opacification.

  3. Genetic modification of Bacillus subtilis for production of D-chiro-inositol, an investigational drug candidate for treatment of type 2 diabetes and polycystic ovary syndrome.

    PubMed

    Yoshida, Ken-ichi; Yamaguchi, Masanori; Morinaga, Tetsuro; Ikeuchi, Maya; Kinehara, Masaki; Ashida, Hitoshi

    2006-02-01

    D-chiro-inositol (DCI) is a drug candidate for the treatment of type 2 diabetes and polycystic ovary syndrome, since it improves the efficiency with which the body uses insulin and also promotes ovulation. Here, we report genetic modification of Bacillus subtilis for production of DCI from myo-inositol (MI). The B. subtilis iolABCDEFGHIJ operon encodes enzymes for the multiple steps of the MI catabolic pathway. In the first and second steps, MI is converted to 2-keto-MI (2KMI) by IolG and then to 3D-(3,5/4)-trihydroxycyclohexane-1,2-dione by IolE. In this study, we identified iolI encoding inosose isomerase, which converts 2KMI to 1-keto-D-chiro-inositol (1KDCI), and found that IolG reduces 1KDCI to DCI. Inactivation of iolE in a mutant constitutively expressing the iol operon blocked the MI catabolic pathway to accumulate 2KMI, which was converted to DCI via the activity of IolI and IolG. The mutant was able to convert at least 6% of input MI in the culture medium to DCI.

  4. Definition of Failed Induction of Labor and Its Predictive Factors: Two Unsolved Issues of an Everyday Clinical Situation.

    PubMed

    Baños, Núria; Migliorelli, Federico; Posadas, Eduardo; Ferreri, Janisse; Palacio, Montse

    2015-01-01

    The objectives of this review were to identify the predictive factors of induction of labor (IOL) failure or success as well as to highlight the current heterogeneity regarding the definition and diagnosis of failed IOL. Only studies in which the main or secondary outcome was failed IOL, defined as not entering the active phase of labor after 24 h of prostaglandin administration ± 12 h of oxytocin infusion, were included in the review. The data collected were: study design, definition of failed IOL, induction method, IOL indications, failed IOL rate, cesarean section because of failed IOL and predictors of failed IOL. The database search detected 507 publications. The main reason for exclusion was that the primary or secondary outcomes were not the predetermined definition of failed IOL (not achieving active phase of labor). Finally, 7 studies were eligible. The main predictive factors identified in the review were cervical status, evaluated by the Bishop score or cervical length. Failed IOL should be defined as the inability to achieve the active phase of labor, considering that the definition of IOL is to enter the active phase of labor. A universal definition of failed IOL is an essential requisite to analyze and obtain solid results and conclusions on this issue. An important finding of this review is that only 7 of all the studies reviewed assessed achieving the active phase of labor as a primary or secondary IOL outcome. Another conclusion is that cervical status remains the most important predictor of IOL outcome, although the value of the parameters explored up to now is limited. To find or develop predictive tools to identify those women exposed to IOL who may not reach the active phase of labor is crucial to minimize the risks and costs associated with IOL failure while opening a great opportunity for investigation. Therefore, other predictive tools should be studied in order to improve IOL outcome in terms of health and economic burden. © 2015 S. Karger AG, Basel.

  5. Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: Trifocal versus extended range of vision.

    PubMed

    Monaco, Gaspare; Gari, Mariangela; Di Censo, Fabio; Poscia, Andrea; Ruggi, Giada; Scialdone, Antonio

    2017-06-01

    To compare the visual outcomes and quality of vision of 2 new diffractive multifocal intraocular lenses (IOLs) with those of a monofocal IOL. Fatebenefratelli e Oftalmico Hospital, Milan, Italy. Prospective case series. Patients had bilateral cataract surgery with implantation of a trifocal IOL (Panoptix), an extended-range-of-vision IOL (Symfony), or a monofocal IOL (SN60WF). Postoperative examinations included assessing distance, intermediate, and near visual acuity; binocular defocus; intraocular and total aberrations; point-spread function (PSF); modulation transfer function (MTF); retinal straylight; and quality-of-vision (QoV) and spectacle-dependence questionnaires. Seventy-six patients (152 eyes) were assessed for study eligibility. Twenty patients (40 eyes) in each arm of the study (60 patients, 120 eyes) completed the outcome assessment. At the 4-month follow-up, the trifocal group had significantly better near visual acuity than the extended-range-of-vision group (P = .005). The defocus curve showed the trifocal IOL had better intermediate/near performance than the extended-range-of-vision IOL and both multifocal IOLs performed better than the monofocal IOL. Intragroup comparison of the total higher-order aberrations, PSF, MTF, and retinal straylight were not statistically different. The QoV questionnaire results showed no differences in dysphotopsia between the multifocal IOL groups; however, the results were significantly higher than in the monofocal IOL group. Both multifocal IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the trifocal IOL might be better for patients with near-vision requirements. The significant perception of visual side effects indicates that patients still must be counseled about these effects before a multifocal IOL is implanted. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Effects of a blue light-filtering intraocular lens on driving safety in glare conditions.

    PubMed

    Gray, Rob; Hill, Warren; Neuman, Brooke; Houtman, Diane; Potvin, Richard

    2012-05-01

    To evaluate whether the previously established benefit of blue light-filtering intraocular lenses (IOLs) when driving in glare conditions is maintained in patients previously implanted with a blue light-filtering toric IOL. Department of Applied Psychology, Arizona State University, Mesa, Arizona, USA. Comparative case series. The study comprised patients with a blue light-filtering toric IOL (test IOL) or an ultraviolet (UV)-only filtering nontoric IOL (control IOL). All patients had good visual acuity and a valid driver's license. While wearing best spherocylindrical correction, patients performed left-turn maneuvers in front of oncoming traffic in a driving simulator. The safety margin was defined as the time to collision less the time taken to turn at an intersection with oncoming traffic. Measures were repeated with a glare source simulating low-angle sun conditions (daytime driving). Of the 33 evaluable patients, 18 had a test IOL and 15 had a control IOL. In the presence of glare, patients with test IOLs had significantly greater safety margins (mean 2.676 seconds ± 0.438 [SD]) than patients with control IOLs (mean 2.179 ± 0.343 seconds) and significantly lower glare susceptibility (P<.05). In no-glare and glare conditions, patients with test IOLs had significantly lower glare susceptibility than patients with control IOLs. The blue light-filtering toric IOL produced a significantly greater reduction in glare disability than the UV-only filtering nontoric IOL and increased the ability of drivers to safely execute left turns in low-sun conditions. Dr. Houtman is an employee of Alcon Laboratories, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Comparative visual performance with monofocal and multifocal intraocular lenses

    PubMed Central

    Gundersen, Kjell Gunnar; Potvin, Richard

    2013-01-01

    Background To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted. Methods Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a single diagnostic visit between 3 and 8 months after second-eye surgery. Lenses tested included an aspheric monofocal and two apodized diffractive multifocal IOLs with slightly different design parameters. A total of 94 patients were evaluated. Results Subjects with the ReSTOR® +2.5 D IOL had better near and intermediate vision than those subjects with a monofocal IOL. Intermediate vision was similar to, and near vision slightly lower than, that of subjects with a ReSTOR® +3.0 D IOL implanted. The preferred reading distance was slightly farther out for the +2.5 D relative to the +3.0 D lens, and farthest for the monofocal. Visual acuity at the preferred reading distance was equal with the two multifocal IOLs and significantly worse with the monofocal IOL. Quality of vision measures were highest with the monofocal IOL and similar between the two multifocal IOLs. Conclusion The data indicate that the ReSTOR +2.5 D IOL provided good intermediate and functional near vision for patients who did not want to accept a higher potential for visual disturbances associated with the ReSTOR +3.0 D IOL, but wanted more near vision than a monofocal IOL generally provides. Quality of vision was not significantly different between the multifocal IOLs, but patient self-selection for each lens type may have been a factor. PMID:24143064

  8. Through-Focus Vision Performance and Light Disturbances of 3 New Intraocular Lenses for Presbyopia Correction

    PubMed Central

    Escandón-García, Santiago; Ribeiro, Filomena J.; McAlinden, Colm

    2018-01-01

    Purpose To compare the through-focus visual performance in a clinical population of pseudophakic patients implanted with two new trifocal intraocular lenses (IOLs) and one extended depth of focus IOL. Methods Prospective, nonrandomized, examiner-masked case series. Twenty-three patients received the FineVision® and seven patients received the PanOptix™ trifocal IOLs. Fifteen patients received the Symfony extended depth of focus IOL. Mean age of patients was 63 ± 8 years. Through-focus visual acuity was measured from –3.00 to +1.00 D vergences. Contrast sensitivity was measured with and without a source of glare. Light disturbances were evaluated with the Light Distortion Analyzer. Results Though-focus evaluation showed that trifocal IOLs performed significantly better at near distance (33 and 40 cm), and extended depth of focus performed significantly better at intermediate distance (1.0 m). Contrast sensitivity function with glare and dysphotopsia was similar between the three IOLs and subjective response to questionnaire showed a significantly higher score (worse performance) for the extended depth of focus IOL compared to both trifocal IOLs in the bothersome subscale (p < 0.05). Conclusions Trifocal IOLs grant better performance at near distance while extended depth of focus IOL performs better at intermediate distance. Objective dysphotopsia measured with the Light Distortion Analyzer is not reduced in extended depth of focus IOL compared to trifocal IOLs. PMID:29651343

  9. Effect of four different intraocular lenses on posterior capsule opacification

    PubMed Central

    Duman, Rahmi; Karel, Fatih; Özyol, Pelin; Ateş, Can

    2015-01-01

    AIM To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates. METHODS This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one clinic. Four different IOLs were assessed. The outcome parameter was the incidence of Nd:YAG laser posterior capsulotomies. RESULTS An Nd:YAG laser posterior capsulotomy was performed in 153 (3.07%) of the 4970 eyes. The mean follow-up time was 84mo for all of the IOL groups. The percentage of eyes developing PCO was significantly greater for the acrylic hydrophilic IOLs than for the hydrophobic IOLs, although eyes with acrylic hydrophilic IOLs did not require Nd:YAG laser capsulotomy as soon as eyes with acrylic hydrophobic IOLs. There was no difference between the long-term PCO rates when 1- and 3-piece acrylic hydrophobic IOLs were compared or when IOLs made of the same material but with different haptic angles were compared. CONCLUSION In this study, eyes with acrylic hydrophilic IOLs were more likely to develop PCO than those with acrylic hydrophobic IOLs. The lens design (1-piece versus 3-piece and varying haptic angles) did not affect the PCO rate. PMID:25709920

  10. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery.

    PubMed

    Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo

    2016-01-01

    The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France). Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.

  11. Introduction to the development of intraocular lens

    NASA Astrophysics Data System (ADS)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  12. Association of height, body weight, age, and corneal diameter with calculated intraocular lens strength of adult horses.

    PubMed

    Mouney, Meredith C; Townsend, Wendy M; Moore, George E

    2012-12-01

    To determine whether differences exist in the calculated intraocular lens (IOL) strengths of a population of adult horses and to assess the association between calculated IOL strength and horse height, body weight, and age, and between calculated IOL strength and corneal diameter. 28 clinically normal adult horses (56 eyes). Axial globe lengths and anterior chamber depths were measured ultrasonographically. Corneal curvatures were determined with a modified photokeratometer and brightness-mode ultrasonographic images. Data were used in the Binkhorst equation to calculate the predicted IOL strength for each eye. The calculated IOL strengths were compared with a repeated-measures ANOVA. Corneal curvature values (photokeratometer vs brightness-mode ultrasonographic images) were compared with a paired t test. Coefficients of determination were used to measure associations. Calculated IOL strengths (range, 15.4 to 30.1 diopters) differed significantly among horses. There was a significant difference in the corneal curvatures as determined via the 2 methods. Weak associations were found between calculated IOL strength and horse height and between calculated IOL strength and vertical corneal diameter. Calculated IOL strength differed significantly among horses. Because only weak associations were detected between calculated IOL strength and horse height and vertical corneal diameter, these factors would not serve as reliable indicators for selection of the IOL strength for a specific horse.

  13. All-distance visual acuity and contrast visual acuity in eyes with a refractive multifocal intraocular lens with minimal added power.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hayashi, Hideyuki

    2009-03-01

    To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL. Comparative, nonrandomized, interventional study. Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL. All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs. At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances. Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P

  14. Evaluating the Biostability of Yellow and Clear Intraocular Lenses with a System Simulating Natural Intraocular Environment

    PubMed Central

    Hayashi, Rijo; Hayashi, Shimmin; Arai, Kiyomi; Yoshida, Shinichirou; Chikuda, Makoto; Machida, Shigeki

    2016-01-01

    Purpose Blue light–filtering intraocular lenses (IOLs) are thought to protect the retina from blue light damage after cataract surgery, and the implantation of yellow-tinted IOLs has been commonly used in cataract surgery. To our knowledge, this is the first investigation measuring the long-term biostability of yellow-tinted IOLs using an in vitro system simulating natural intraocular environment. Methods Six hydrophobic acrylic IOLs, three clear IOLs, and three yellow-tinted IOLs were included in the study. Each yellow-tinted IOL was a matching counterpart of a clear IOL, with the only difference being the lens color. The IOLs were kept in conditions replicating the intraocular environment using a perfusion culture system for 7 months. Resolution, light transmittance rate, and the modulation transfer function (MTF) were measured before and after culturing. Surface roughness of the anterior and posterior surfaces was also measured. Results After culturing for 7 months, there were no changes in the resolution, the light transmittance rate, and MTF. The surface roughness of the anterior and posterior surfaces increased after culturing; however, this increase was clinically insignificant. There were no differences in surface roughness between the clear and yellow-tinted IOLs, either before or after culturing. Conclusions A novel in vitro system replicating intraocular environment was used to investigate the biostability of yellow-tinted IOLs. The surface roughness showed no clinically significant increase after culturing for 7 months. Translational Relevance This system is useful for evaluating the biostability of IOLs. PMID:27933221

  15. The Effect of Lens Sphere and Cylinder Power on Residual Astigmatism and Its Resolution After Toric Intraocular Lens Implantation.

    PubMed

    Berdahl, John P; Hardten, David R; Kramer, Brent A; Potvin, Richard

    2017-03-01

    To analyze correlations between residual refractive cylinder (and its correction through lens reorientation) with the sphere and cylinder power of the toric intraocular lens (IOL) implanted. An online toric back-calculator (www.astigmatismfix.com) allows users to input toric IOL planning data, along with postoperative IOL orientation and refractive results; these data are used to determine the optimal orientation of the IOL to reduce refractive astigmatism. This was a retrospective data analysis; aggregate historical data were extracted from this calculator to investigate the relationship between residual refractive astigmatism and IOL cylinder and sphere power. A total of 12,812 records, 4,619 of which included IOL sphere power, were available for analysis. There was no significant effect of sphere power on residual refractive astigmatism (P = .25), but lower IOL cylinder powers were associated with significantly lower residual refractive astigmatism (P < .05). The difference between the intended and ideal orientation was higher in the lower IOL cylinder power groups (P < .01). Overcorrection of astigmatism was significantly more likely with higher IOL cylinder power (P < .01), but not with sphere power (P = .33). Reorientation to correct residual refractive cylinder to less than 0.50 diopters (D) was more successful with IOL cylinder powers of 1.50 D or less (P < .01); IOL sphere power had no apparent effect. There were significant effects of IOL cylinder power on residual refractive astigmatism, the difference between intended and ideal orientation, the likelihood of overcorrection, and the likelihood of astigmatism reduction with lens reorientation. IOL sphere power appeared to have no such effects. [J Refract Surg. 2017;33(3):157-162.]. Copyright 2017, SLACK Incorporated.

  16. Management of sulcus-fixated single-piece intraocular lens-induced pigmentary glaucoma with 3-piece IOL exchange.

    PubMed

    Rabie, Hossein Mohammad; Esfandiari, Hamed; Rikhtegar, Mohammad Hassan; Hekmat, Vahid

    2018-02-01

    To describe our experience with exchanging sulcus-fixated single-piece intraocular lens (IOL) with 3-piece IOLs for management of pigmentary glaucoma. In this retrospective study, records of patients who underwent sulcus-fixated single-piece IOL exchanged with 3-piece IOLs were retrieved, and demographic and baseline data of patients, type of IOL, pre- and post-IOL exchange BCVA, IOP, number of anti-glaucoma medications, and optic nerve head examination were documented. Baseline and final examinations were analyzed and compared. Mean age of the patients was 59 ± 10 years, and 5 (41.6%) were female. Mean interval between primary cataract extraction operation and IOL exchange was 17 ± 5 months. Nine patients received in sulcus implantation of Alcon SA60AT, and three patients had SN60WF model at the end of primary surgery. BCVA changed insignificantly from 0.06 ± 0.06 logMAR to 0.06 ± 0.06 after IOL exchange. (P = 0.22) IOP was controlled in 8 cases (66.6%), but four cases (33.3%) needed glaucoma surgery to further control glaucoma condition. IOP decreased significantly from preoperative 17 ± 3 to 14 ± 1 mmHg postoperatively. Patients with advanced age and higher baseline IOP were more likely to undergo glaucoma surgery after IOL exchange. (P = 0.07 and 0.00, respectively). single-piece IOL exchange with 3-piece IOL dramatically decreases pigment release and reduces IOP. Those with advanced age and higher IOP are less likely to respond to IOL exchange and may need glaucoma surgery to control high intraocular pressure.

  17. Evaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.

    PubMed

    Garzón, Nuria; Poyales, Francisco; de Zárate, Begoña Ortíz; Ruiz-García, Jose Luis; Quiroga, Juan Antonio

    2015-02-01

    To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin, Germany], enVista [Bausch & Lomb, Rochester, NY], and AcrySof IQ [Alcon Laboratories, Inc., Fort Worth, TX]) and one multifocal toric IOL (AcrySof IQ ReSTOR; Alcon Laboratories, Inc.) were implanted. Preoperative and postoperative images were taken to calculate the misalignment due to the marking method. To evaluate rotation in the different follow-up visits, another photograph was taken 1 hour and 1, 7 and 30 days postoperatively. Refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity were measured 30 days postoperatively. Postoperative UDVA was 0.1 logMAR or better in 64.6% of eyes implanted with monofocal IOLs and 46.4% of eyes implanted with multifocal IOLs. The enVista toric IOL showed the best UDVA compared to the other monofocal IOLs, with 81% of eyes with 0.1 logMAR or better. The mean misalignment in the total group studied was 0.07° ± 0.60°; 69.6% of monofocal IOLs and 67.9% of multifocal IOLs showed less than 5° of rotation. A correlation was found between postoperative UDVA and rotation in the monofocal and multifocal IOLs implanted (r = 0.439 [P < .011] and = 0.787 [P = .001], respectively). At 1 month postoperatively, UDVA was slightly more affected by IOL rotation in multifocal than monofocal toric IOLs. The marking method was also effective. Copyright 2015, SLACK Incorporated.

  18. Identification of a Gene Cluster Enabling Lactobacillus casei BL23 To Utilize myo-Inositol▿ †

    PubMed Central

    Yebra, María Jesús; Zúñiga, Manuel; Beaufils, Sophie; Pérez-Martínez, Gaspar; Deutscher, Josef; Monedero, Vicente

    2007-01-01

    Genome analysis of Lactobacillus casei BL23 revealed that, compared to L. casei ATCC 334, it carries a 12.8-kb DNA insertion containing genes involved in the catabolism of the cyclic polyol myo-inositol (MI). Indeed, L. casei ATCC 334 does not ferment MI, whereas strain BL23 is able to utilize this carbon source. The inserted DNA consists of an iolR gene encoding a DeoR family transcriptional repressor and a divergently transcribed iolTABCDG1G2EJK operon, encoding a complete MI catabolic pathway, in which the iolK gene probably codes for a malonate semialdehyde decarboxylase. The presence of iolK suggests that L. casei has two alternative pathways for the metabolism of malonic semialdehyde: (i) the classical MI catabolic pathway in which IolA (malonate semialdehyde dehydrogenase) catalyzes the formation of acetyl-coenzyme A from malonic semialdehyde and (ii) the conversion of malonic semialdehyde to acetaldehyde catalyzed by the product of iolK. The function of the iol genes was verified by the disruption of iolA, iolT, and iolD, which provided MI-negative strains. By contrast, the disruption of iolK resulted in a strain with no obvious defect in MI utilization. Transcriptional analyses conducted with different mutant strains showed that the iolTABCDG1G2EJK cluster is regulated by substrate-specific induction mediated by the inactivation of the transcriptional repressor IolR and by carbon catabolite repression mediated by the catabolite control protein A (CcpA). This is the first example of an operon for MI utilization in lactic acid bacteria and illustrates the versatility of carbohydrate utilization in L. casei BL23. PMID:17449687

  19. Effect of number and position of intraocular lens haptics on anterior capsule contraction: a randomized, prospective trial.

    PubMed

    Choi, Mihyun; Lazo, Marjorie Z; Kang, Minji; Lee, Jeehye; Joo, Choun-Ki

    2018-03-20

    The present study aimed to evaluate the degree of anterior capsule contraction (capsulorhexis contraction) with three different single-piece, hydrophilic acrylic intraocular lenses (IOLs). Patients were prospectively randomized to be implanted with one of three types of IOLs during cataract surgery: the Ophtec Precizon (IOL A), the Lucid Korea Microflex (IOL B), and the Carl Zeiss Asphina (IOL C). One week, 2 weeks, and 6 months after surgery, the area of the anterior capsule opening was measured using digital retro-illumination images after dilation of the pupil. The data were then evaluated using POCOman software. The study included 236 eyes of 202 patients. The area of the anterior capsule opening reduced by 3.53 ± 3.31 mm (17.06% ± 15.99%) between 1 week and 2 months post-operatively in the IOL A group, by 0.62 ± 1.32 mm (2.87% ± 6.03%) in the IOL B group, and by 1.09 ± 1.53 mm (4.72% ± 6.10%) in the IOL C group. The IOL B group showed minimal anterior capsule contraction 2 months after surgery (p < 0.001). IOLs with a four-plate haptic design (IOL B) showed more anterior capsular stability than those with a two-loop plate haptic (IOL A) or two-plate haptic (IOL C) design. The number and position of haptics in a capsular bag may affect anterior capsule contraction. We assume that supporting the zonules evenly may play a role in anterior capsular stability. Current Controlled Trials ISRCTN76566080 , Retrospectively registered (Date of registration: 14 Feb 2018).

  20. Assessment of a new hydrophilic acrylic supplementary IOL for sulcus fixation in pseudophakic cadaver eyes

    PubMed Central

    Reiter, N; Werner, L; Guan, J; Li, J; Tsaousis, K T; Mamalis, N; Srinivasan, S

    2017-01-01

    Purpose Management of refractive errors after cataract surgery includes spectacles or contact lens, secondary laser vision correction, intraocular lens (IOL) exchange, or piggyback lens implantation. We evaluated for the first time a single-piece hydrophilic acrylic IOL designed for supplementary sulcus fixation in postmortem pseudophakic human eyes. Methods Pseudophakic human cadaver eyes were imaged by anterior segment optical coherence tomography (AS-OCT) to assess position of the primary IOL. Eyes were prepared as per the Miyake-Apple technique. The supplementary IOL (Medicontur A4 Addon IOL family) was then inserted into the ciliary sulcus. AS-OCT and photographs from anterior and posterior views were used to assess IOL centration, tilt, and interlenticular distance from the primary IOL. Results Data were obtained from 12 eyes having primary IOLs of varying materials and designs in the bag and representing different sizes of eyes and severity of Soemmering's ring formation. The A4 Addon IOL was successfully inserted into the ciliary sulcus and was well centered in all cases. Four cases of tilt were observed on AS-OCT: three with mild tilt due to pre-existing zonular dehiscence, and one due to a localized area of Soemmering's ring formation. Interlenticular distance ranged from 0.34 to 1.24 mm and was not dependent on severity of Soemmering's ring or type of primary IOL. Conclusions The A4 Addon IOL was designed for sulcus fixation as a supplementary lens, with a large diameter, a square-shaped optic, four smooth loop haptics, and a convex–concave optical surface. It exhibited appropriate centration and interlenticular distance with different primary in-the-bag IOLs. PMID:28106890

  1. Management of dislocated intraocular lenses with iris suture.

    PubMed

    Faria, Mun Y; Ferreira, Nuno P; Canastro, Mario

    2017-01-19

    Subluxated or malpositioned intraocular lenses (IOLs) and inadequate capsular support is a challenge for every ophthalmic surgeon. Iris suture of an IOL seems to be an easy technique for the management of dislocated 3-piece IOL, allowing the IOL to be placed behind the iris, far from the trabecular meshwork and corneal endothelium. The purpose of this study is to assess the results of pars plana vitrectomy (PPV) and iris suture of dislocated 3-piece acrylic IOLs. In this retrospective, nonrandomized, interventional case consecutive study, of a total of 103 dislocated IOLs, 36 eyes were considered for analysis. All 36 eyes had subluxated or totally luxated 3-piece IOL and underwent iris suture at the Ophthalmology Department of Santa Maria Hospital-North Lisbon Hospital Center, Portugal, from January 2011 until November 2015. All patients underwent 3-port 23-G PPV. The optic zone of the dislocated IOL was placed anterior to the iris with the haptics behind, in the posterior chamber. Haptics were sutured to iris followed by placement of the optics behind iris plane. Postoperative measures included best-corrected visual acuity (BCVA), IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and development of macular edema. A total of 36 eyes of 36 patients were included. All underwent successful iris fixation of dislocated 3-piece IOL. Mean overall follow-up was 15.9 months (range 3-58 months). At presentation, 16 eyes (44.4%) had a luxated IOL and 20 eyes (55.6%) a subluxated IOL. As underlying cause, 17 eyes (47.2%) had a history of complicated cataract surgery, 5 eyes (13.9%) had a traumatic dislocation of the IOL, and 6 eyes (16.7%) had a previous vitreoretinal surgery. A total of 8 eyes (22.2%) had late spontaneous IOL dislocation after uneventful cataract surgery. The mean preoperative BCVA was 1.09 ± 0.70 logarithm of the minimal angle of resolution (logMAR) units and mean postoperative BCVA was 0.48 ± 0.58 of logMAR units. The mean visual acuity improvement was 4.08 ± 5.33 lines on the logMAR scale. In this study, every IOL was stable at the last follow-up. As late complications, macular edema occurred in 1 patient and retinal detachment occurred in 2 patients. There were no cases of endophthalmitis. Iris suture fixation of subluxated IOL is a good treatment option for eyes with dislocated IOLs, leading to long-term stability of the IOL. The advantage of this procedure is using the same IOL in a closed eye surgery. No astigmatic difference is expected as no large corneal incision is needed.

  2. Prospective multicenter clinical trial to evaluate the safety and effectiveness of a new glistening-free one-piece acrylic toric intraocular lens.

    PubMed

    Packer, Mark; Williams, Jon I; Feinerman, Gregg; Hope, Richard S

    2018-01-01

    Glistening formation in the intraocular lens (IOL) optic has the potential to impact quality of vision. The enVista One-Piece Hydrophobic Acrylic Spherical IOL Model MX60 (MX60 IOL) is currently the only US Food and Drug Administration-approved IOL with a label of "no glistenings". The purpose of this prospective, multicenter, partially randomized, partially controlled, double-masked, pivotal study was to evaluate the safety and effectiveness of the enVista One-Piece Hydrophobic Acrylic MX60T Toric IOL (enVista MX60T Toric IOL). Subjects (n=191) were implanted with the enVista MX60T Toric IOL (cylinder powers 1.25, 2.00, or 2.75 D) or the parent MX60 IOL (control). Eyes within the lowest range of corneal astigmatism were randomized to receive either Toric 1.25 D IOL or control IOL in a 1:1 ratio. All subjects with corneal astigmatism requiring 2.00 or 2.75 D cylinder IOLs received toric IOLs. Rotational stability, cylinder reduction, and best-corrected distance visual acuity were primary effectiveness endpoints measured at Visit 4 (120-180 days postoperatively). Visit 4 mean absolute axis misalignment in the All Toric group was 4.68°±7.33°, and all subjects had ≤5° absolute rotation from Visit 3 to Visit 4. The 1.25 D group had significantly greater improvement in dioptric cylinder reduction ( P <0.001), percent cylinder reduction ( P <0.001), and mean uncorrected distance visual acuity ( P <0.001), compared to control at Visit 4. Most adverse events (AEs) were mild, with no serious AEs in the study eyes. The rates of cumulative AEs through Visit 4 were below International Organization for Standardization (ISO) standard 11979-7 AE rates. enVista MX60T Toric IOL is safe and effective for patients with preoperative corneal astigmatism undergoing IOL implantation.

  3. Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: a UK Real World Evidence study.

    PubMed

    Ursell, Paul G; Dhariwal, Mukesh; Majirska, Katarina; Ender, Frank; Kalson-Ray, Shoshannah; Venerus, Alessandra; Miglio, Cristiana; Bouchet, Christine

    2018-06-11

    To evaluate 3-year incidence of Nd:YAG capsulotomy and PCO and compare the effect of different IOL materials. Data were retrospectively collected from seven UK ophthalmology clinics using Medisoft electronic medical records. Eyes from patients ≥65 years undergoing cataract surgery with implantation of acrylic monofocal IOLs during 2010-2013 and 3-year follow-up were analysed. Nd:YAG capsulotomy and PCO incidence proportions were reported for 3 IOL cohorts: AcrySof, other hydrophobic and hydrophilic acrylic IOLs. Unadjusted/adjusted odds ratios (OR) of Nd:YAG capsulotomy were calculated through logistic regression for non-AcrySof cohorts versus AcrySof. A sub-group analysis in single-piece IOLs (>90% of sample eyes) was also performed. The AcrySof cohort included 13,329 eyes, non-AcrySof hydrophobic 19,025 and non-AcrySof hydrophilic 19,808. The 3-year Nd:YAG capsulotomy incidence (95% CI) for AcrySof (2.4%, 2.2-2.7%) was approximately two times lower than non-AcrySof hydrophobic IOLs (4.4%, 4.1-4.7%) and approximately fourfold lower than non-AcrySof hydrophilic IOLs (10.9%, 10.5-11.3%). Trends were similar in PCO incidence (AcrySof: 4.7%; non-AcrySof hydrophobic: 6.3%; non-AcrySof hydrophilic: 14.8%). Also in the analysis restricted to single-piece IOLs, the pattern remained (2.4% vs 5.1% vs. 10.9%, respectively). Adjusted regression analysis showed a approximately two and fivefold increased odds of Nd:YAG for non-AcrySof hydrophobic and hydrophilic acrylic IOLs respectively vs. AcrySof IOLs. Nd:YAG capsulotomy ORs were similar and remained statistically significant in the single-piece IOL sub-group. Real-world evidence shows that within 3 years following implantation, AcrySof IOLs are significantly superior in reducing Nd:YAG capsulotomy and PCO incidence compared to other hydrophilic and hydrophobic acrylic IOLs.

  4. Crystalens HD intraocular lens analysis using an adaptive optics visual simulator.

    PubMed

    Pérez-Vives, Cari; Montés-Micó, Robert; López-Gil, Norberto; Ferrer-Blasco, Teresa; García-Lázaro, Santiago

    2013-12-01

    To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were measured for both IOL optics. Near VA (NVA) and CS were measured for the Crystalens HD IOL in its accommodative state. Depth of focus around the distance and near focus was also evaluated for the Crystalens HD IOL. Modulation transfer function (MTF), point spread function (PSF), and Strehl ratio were also calculated. All measures were taken for 3- and 5-mm pupils. The MTF, PSF, and Strehl ratio showed comparable values between IOLs (p > 0.05). There were no significant differences in DVA and CS between IOLs for all contrasts and pupils (p > 0.05). When spherically focused, mean DVA and NVA with the Crystalens HD IOL were ≥20/20 at 100 and 50% contrasts for both pupils. Monocular DVA, NVA, and CS were slightly better with 3- than 5-mm pupils, but without statistically significant differences. The Crystalens HD IOL showed about 0.75 and 0.50 D of depth of focus in its accommodative state and nonaccommodative state, respectively. The optical and visual quality with the nonaccommodatied Crystalens HD IOL was comparable to that of a monofocal IOL. If this lens can move 1.4 mm in the eye, it will provide high-quality optics for near vision as well.

  5. Intraocular lens bioactivity tested using rabbit corneal tissue cultures.

    PubMed

    Linnola, R J; Salonen, J I; Happonen, R P

    1999-11-01

    To evaluate the effects of different intraocular lens (IOL) materials on epithelial cell growth to test the sandwich theory; i.e., a bioactivity-based explanation of posterior capsule opacification (PCO) after cataract surgery. Central Hospital, Vaasa, and Institute of Dentistry and Turku Center for Biomaterials, University of Turku, Finland. Rabbit corneal tissue cultures were set up on poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, silicone, acrylate, and hydrogel IOLs for 1 week. The tissue consisted of intact epithelium and half the thickness of the corneal stroma, which was placed against the IOL. The growth of the epithelium was examined by light microscopy to evaluate the attachment of the corneal explant to the IOL surface. All tissue samples grew well under the culture conditions. When grown on PMMA, HSM PMMA, silicone, and hydrogel, the tissue did not attach to the IOL or the epithelium grew around the explant, suggesting that the attachment of the stroma to the IOL was poor or nonexistent. Some explants on acrylate IOLs attached directly to the IOL surface with no epithelial ingrowth between the stroma and the IOL. This tissue culture method can be used to examine the behavior of corneal tissue in contact with different IOL materials. The results suggest that the acrylate IOL may have bioactive properties. This, with the lens optic's square edge, may hinder lens epithelial cell proliferation and thus prevent PCO.

  6. Role of intraocular lens parameters in visual rehabilitation of patients after extracapsular cataract extraction

    NASA Astrophysics Data System (ADS)

    Bakutkin, Valery V.; Galanzha, Vladimir A.

    2001-01-01

    The main method of cataract treatment is micro surgical removing of the opaque lens from the eye with implantation of an intra ocular lens. We performed the comparative study of using various IOL models differing in its materials, index of refraction, spectral properties, configuration, shape, size and other features. Before and after the IOL implantation we performed the following test: visual acuity measuring, refractometry, keratometry, laser interferometric retinometry, color perception assessment, digital photo- and videorecording of the eye with image processing and some others. We found a number of correlations between the IOL properties and some characteristics of the patient's vision. The decentration of the IOL optical part more than 1,5 mm conduced to the non-corneal astigmatism and the prismatic effect. A small diameter of the IOL optical part and high index of refraction promotes to the appearance of the optical aberrations. Leucosapphire IOLs revealed the high degree of light reflection and the minimal adhesive ability of the IOL surface. Leucosapphire IOL revealed the high degree of light reflection and the minimal adhesive ability of the IOL surface. PMMA IOL revealed the low reflective power and the high adhesive ability. The best color vision was revealed in patients with PMMA IOL with an additional compound absorbing not only UV light but also short-wave blue light.

  7. Variation in clinical decision-making for induction of labour: a qualitative study.

    PubMed

    Nippita, Tanya A; Porter, Maree; Seeho, Sean K; Morris, Jonathan M; Roberts, Christine L

    2017-09-22

    Unexplained variation in induction of labour (IOL) rates exist between hospitals, even after accounting for casemix and hospital differences. We aimed to explore factors that influence clinical decision-making for IOL that may be contributing to the variation in IOL rates between hospitals. We undertook a qualitative study involving semi-structured, audio-recorded interviews with obstetricians and midwives. Using purposive sampling, participants known to have diverse opinions on IOL were selected from ten Australian maternity hospitals (based on differences in hospital IOL rate, size, location and case-mix complexities). Transcripts were indexed, coded, and analysed using the Framework Approach to identify main themes and subthemes. Forty-five participants were interviewed (21 midwives, 24 obstetric medical staff). Variations in decision-making for IOL were based on the obstetrician's perception of medical risk in the pregnancy (influenced by the obstetrician's personality and knowledge), their care relationship with the woman, how they involved the woman in decision-making, and resource availability. The role of a 'gatekeeper' in the procedural aspects of arranging an IOL also influenced decision-making. There was wide variation in the clinical decision-making practices of obstetricians and less accountability for decision-making in hospitals with a high IOL rate, with the converse occurring in hospitals with low IOL rates. Improved communication, standardised risk assessment and accountability for IOL offer potential for reducing variation in hospital IOL rates.

  8. Astigmatism and Refractive Outcome After Late In-The-Bag Intraocular Lens Dislocation Surgery: A Randomized Clinical Trial.

    PubMed

    Kristianslund, Olav; Østern, Atle Einar; Drolsum, Liv

    2017-09-01

    To compare surgically induced astigmatism (SIA) and refractive outcomes between two operation methods for late in-the-bag IOL dislocation. In this prospective, randomized, parallel-group clinical trial, 104 patients (eyes) were assigned to IOL repositioning by scleral suturing 1.5- to 2-mm posterior to limbus (n = 54) or IOL exchange with a retropupillar iris-claw IOL using a 5.5-mm scleral pocket incision (n = 50). The SIA was determined by vector analysis through conversion of corneal cylinders to Cartesian coordinates, and is presented as magnitude in diopters @ direction in degrees (D @ °). Follow-up was 6 months. The SIA was 0.24 D @ 8° for IOL repositioning and 0.65 D @ 171° for IOL exchange, which was a nonsignificant group difference (X coordinate: P = 0.08; Y coordinate: P = 0.16). Mean SIA magnitude was 0.60 ± 0.50 D and 1.12 ± 0.85 D, respectively (P < 0.001). Mean postoperative spherical equivalent was -1.6 ± 1.6 D after IOL repositioning and -0.5 ± 1.0 D after IOL exchange (P < 0.001). For IOL repositioning, this represented a mean myopic shift of -0.7 ± 1.1 D compared with before the IOL dislocation (P < 0.001). For IOL exchange, it was within ±1 D of target refraction in 83% of the patients. Surgically induced astigmatism was modest in both operation groups, albeit with a tendency of being more pronounced for IOL exchange. Repositioning surgery led to a myopic shift, whereas exchange surgery provided good refractive predictability.

  9. Safety assessment of a new single-use small-incision injector for intraocular lens implantation.

    PubMed

    Satanovsky, Alexandra; Ben-Eliahu, Shmuel; Apple, David J; Kleinmann, Guy

    2011-07-01

    To evaluate the safety of a new injector, the Raysert R-INJ-04/18, for implantation of the C-flex intraocular lens (IOL). Ophthalmology Department, Kaplan Medical Center, Rehovot, Israel. Experimental study. Sixty IOLs were subdivided into 2 equally sized groups. Group A IOLs were injected using the established R-INJ-04 injector, and those in Group B were injected with the new injector. The IOLs were injected into a Petri dish. Subsequently, all IOLs and injectors were evaluated macroscopically and microscopically and then photographed under light microscopy (LM). Two IOLs in each group were randomly chosen and sent for evaluation by scanning electron microscopy (SEM) and energy dispersive analysis of x-ray. All remaining IOLs were sent for power and modulation transfer function (MTF) analysis. All Group B IOLs were successfully injected without evident signs of scratching, cracks, or deposits on LM and SEM examination. In Group A, findings were confined to a singular incidence of a small deposit detected on the periphery of the posterior optical surface of the IOL, with corresponding findings detected on the injector nozzle. No signs of scratching, cracks, or deposits were found in the rest of the IOLs or injectors. The power and MTF analyses were within the normal range for all IOLs. The new 1.8 mm external diameter soft-tipped injector for 2.4 to 2.2 mm incisions was shown to be safe for the implantation of the C-flex 21.0 diopter IOL. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. [IOL and aniseikonia calculation combined with documentation of surgical data and IOL inventory].

    PubMed

    Bastian, G O; Hiss, P

    1992-08-01

    The exact recording of operation data is a precondition for keeping the standards high in cataract surgery, but surgeons are reluctant to answer a questionnaire after a strenuous operation. We have designed a program easy to use in the Macintosh Hypercard System that covers all aspects of cataract surgery such as: (1) the operating record; (2) a data sheet for recording the various details of the operation; (3) recording of the data on hard disc; (4) managing the IOL stock list; (5) proposal of IOL models that are in stock with regard to IOL power (SRK2) and aniseiconia. This program enables the surgeon to record the operation data with effortless ease and it is well accepted. There is no dictation. The operating record and data sheet are printed immediately. The program is controlled by a "mouse". Selection of the suitable IOL model is facilitated by the link between the calculation of IOL power and the IOL stock list. In special cases the IOL power can be changed to obtain less aniseiconia.

  11. [Spectral transmission in blue filter intraocular lenses].

    PubMed

    Schrage, N

    2012-02-01

    There is uncertainty in ophthalmology concerning the quality and spectral transmission of light of so-called blue filter intraocular lenses (IOL). Clinical users have noticed that such IOL's appear to have different color intensities. The discussion on medical changes by means of such IOL's is dependent on the real light transmission of these IOL's. To add some objective data we compared these IOL's by systematic transmission measurements and observed technical differences of diffraction and geometry as well as transmission differences. The result gives objective indications that differences between blue filter IOL's from different manufacturers are important and are detailed in this paper.

  12. Rotational stability of 2 intraocular lenses with an identical design and different materials.

    PubMed

    Draschl, Petra; Hirnschall, Nino; Luft, Nikolaus; Schuschitz, Sandra; Wiesinger, Jörg; Rigal, Karl; Findl, Oliver

    2017-02-01

    To evaluate the rotational stability of nontoric intraocular lenses (IOLs) of the same design and different materials. Vienna Institute for Research in Ocular Surgery, Department of Ophthalmology, Hanusch Hospital, Vienna, Austria. Prospective randomized case series. This study included cataract patients with a corneal astigmatism of less than 1.75 diopters measured with the IOLMaster 500. Each patient received a hydrophilic IOL (Pod Ay 26P) in 1 eye and a hydrophobic IOL (Podeye) in the other eye. One hour and 3 months postoperatively, retroillumination photographs were taken to assess rotational stability of the IOLs. In addition, autorefraction, subjective refraction, and Purkinje meter measurements were performed at the 3-month follow-up. Eighty eyes of 40 patients were included in this study. Three months postoperatively, the IOL rotation within the first 3 months was 2.4 degrees ± 1.85 (SD) in the hydrophilic IOL group and 1.6 ± 1.61 degrees in the hydrophobic IOL group. This difference was statistically significant (P = .016). The hydrophobic IOL was rotationally more stable than the hydrophilic IOL, although both IOLs provided good capsular bag stability. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Inability to perform posterior segment monitoring by scanning laser ophthalmoscopy or optical coherence tomography with some occlusive intraocular lenses in clinical use.

    PubMed

    Yusuf, Imran H; Peirson, Stuart N; Patel, Chetan K

    2012-03-01

    To evaluate whether occlusive intraocular lenses (IOLs) produced by several manufacturers for clinical use equivalently transmit near-infrared (IR) light for scanning laser ophthalmoscopy (SLO) or optical coherence tomography (OCT) imaging. Nuffield Laboratory of Ophthalmology, Oxford University, United Kingdom. Evaluation of diagnostic test or technology. The study evaluated 6 black IOLs of 2 designs: 3 poly(methyl methacrylate) (PMMA) and 3 iris-claw anterior chamber IOLs. Each IOL was placed between a broad-spectrum white light source and a spectroradiometer to generate transmission spectra. Transmission in the near-IR range was examined using an 850 nm light-emitting diode. Scanning laser ophthalmoscopy or OCT imaging using Spectralis spectral-domain SLO or OCT was attempted through occlusive IOLs in a model eye. Artisan iris-claw and MS 612 PMMA occlusive IOLs totally occluded all wavelengths of light, including in the near IR range in which SLO and OCT imaging systems operate. It was not possible to capture SLO or OCT images through the iris-claw and PMMA occlusive IOLs in a model eye. Results suggest the property of near-IR transmission that permits SLO or OCT imaging through occlusive IOLs is restricted to the Morcher range of occlusive IOLs. Patients with non-near IR transmitting IOLs will not be able to receive detailed posterior segment monitoring with SLO or OCT. This finding may have a significant impact on preoperative occlusive IOL selection and the management of current patients with occlusive IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases

    PubMed Central

    Matsushima, Hiroyuki; Nagata, Mayumi; Katsuki, Yoko; Ota, Ichiro; Miyake, Kensaku; Beiko, George H.H.; Grzybowski, Andrzej

    2015-01-01

    Background To report on five patients with decreased visual acuity due to glistening and severe sub-surface nano-glistening (SSNG) formation within their intraocular lenses (IOLs). Design Case reports and analysis of extracted IOLs. Participants and samples We report improved visual acuity when IOLs with severe glistening and SSNG were exchanged for clear IOLs in five patients. Methods Case reports. Main outcome measures The main outcome measure was visual acuity. The secondary outcome measure was light transmission. Explanted IOLs were subjected to investigation. Pre- and postoperative slit lamp images of the anterior eye and microscopic images of the extracted IOLs were taken and compared. Light transmission of the IOL was measured using a double beam type spectrophotometer. An integrated value of the percentage light transmittance in the visible light spectrum was calculated. Results We report on five patients whose visual acuity improved when IOLs were exchanged because of severe glistening and SSNG. All of the affected IOLs were MA60BM (Alcon, Forth Wroth Texas, USA) and the original implantation had occurred over a range of 6–15 years prior to the IOL exchange. Light transmission was decreased in all affected lenses compared to a similar control IOL. Conclusions Although only a few reports of cases in which glistening and SSNG have progressed to the level of decreased visual function have been published, the likelihood is that this phenomena will increase as the severity and incidence of these inclusions have been shown to increase with time. Appropriate evaluations of visual function in such patients are needed and consideration should be given to IOL exchange in symptomatic patients. PMID:26586975

  15. Rotation and decentration of an undersized plate-haptic trifocal toric intraocular lens in an eye with moderate myopia.

    PubMed

    Giers, Bert C; Khoramnia, Ramin; Weber, Lea F; Tandogan, Tamer; Auffarth, Gerd U

    2016-03-01

    We present the case of a 56-year-old woman with moderate myopia and bilateral cataract who had cataract extraction and intraocular lens (IOL) implantation. Due to the patient's desire for spectacle independence, a trifocal IOL with toric correction for astigmatism was implanted. During the follow-up, it became obvious that the implanted IOL had rotated and tilted due to insufficient fixation in the large capsular bag of the myopic eye. An IOL explantation was therefore performed, and the original IOL was exchanged for a bifocal toric IOL with a larger overall diameter. Stable fixation of the IOL in the capsular bag was achieved, and after surgery in the second eye, the patient recovered good bilateral vision. This case illustrates the need for careful selection of IOL diameter and sizing even in patients with moderate myopia due to the potentially larger ocular dimensions in these patients. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    PubMed

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  17. IOL calculation using paraxial matrix optics.

    PubMed

    Haigis, Wolfgang

    2009-07-01

    Matrix methods have a long tradition in paraxial physiological optics. They are especially suited to describe and handle optical systems in a simple and intuitive manner. While these methods are more and more applied to calculate the refractive power(s) of toric intraocular lenses (IOL), they are hardly used in routine IOL power calculations for cataract and refractive surgery, where analytical formulae are commonly utilized. Since these algorithms are also based on paraxial optics, matrix optics can offer rewarding approaches to standard IOL calculation tasks, as will be shown here. Some basic concepts of matrix optics are introduced and the system matrix for the eye is defined, and its application in typical IOL calculation problems is illustrated. Explicit expressions are derived to determine: predicted refraction for a given IOL power; necessary IOL power for a given target refraction; refractive power for a phakic IOL (PIOL); predicted refraction for a thick lens system. Numerical examples with typical clinical values are given for each of these expressions. It is shown that matrix optics can be applied in a straightforward and intuitive way to most problems of modern routine IOL calculation, in thick or thin lens approximation, for aphakic or phakic eyes.

  18. Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation

    PubMed Central

    Hayashi, K.; Hayashi, H.; Nakao, F.; Hayashi, F.

    2001-01-01

    AIM—To prospectively investigate changes in the area of the anterior capsule opening, and intraocular lens (IOL) decentration and tilt after implantation of a hydrogel IOL.
METHODS—100 patients underwent implantation of a hydrogel IOL in one eye and an acrylic IOL implantation in the opposite eye. The area of the anterior capsule opening, and the degree of IOL decentration and tilt were measured using the Scheimpflug videophotography system at 3 days, and at 1, 3, and 6 months postoperatively.
RESULTS—The mean anterior capsule opening area decreased significantly in both groups. At 6 months postoperatively, the area in the hydrogel group was significantly smaller than that in the acrylic group. The mean percentage of the area reduction in the hydrogel group was also significantly greater than that in the acrylic group, being 16.9% in the hydrogel group and 8.8% in the acrylic group. In contrast, IOL decentration and tilt did not progress in either group. No significant differences were found in the degree of IOL decentration and tilt throughout the follow up period.
CONCLUSIONS—Contraction of the anterior capsule opening was more extensive with the hydrogel IOL than with the acrylic IOL, but the degree of IOL decentration and tilt were similar for the two types of lenses studied.

 PMID:11673291

  19. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma.

    PubMed

    Mierlo, Camille Van; Pinto, Luis Abegão; Stalmans, Ingeborg

    2015-01-01

    Iatrogenic pigment dispersion syndrome generally originates from a repetitive, mechanical trauma to the pigmented posterior epithelium of the iris. This trauma can arise after intraocular surgery, most commonly due to an abnormal contact between the intraocular lens (IOL) and the iris. Whether surgical removal of this primary insult can lead to a successful intraocular pressure (IOP) control remains unclear. Case-series. Patients with IOP elevation and clinical signs of pigment dispersion were screened for a diagnosis of iatrogenic IOL-related pigment dispersion. Three patients in which the IOL or the IOL-bag complex caused a pigment dispersion through a repetitive iris chafing were selected. In two cases, replacement of a sulcus-based single-piece IOL (patient 1) or a sub-luxated in-the-bag IOL (patient 2) by an anterior-chamber (AC) iris-fixed IOL led to a sustained decrease in IOP. In the third case, extensive iris atrophy and poor anatomical AC parameters for IOL implantation precluded further surgical intervention. IOL-exchange appears to be a useful tool in the management of iatrogenic pigment dispersion glaucoma due to inappropriate IOL implantation. This cause-oriented approach seems to be effective in controlling IOP, but should be offered only if safety criteria are met. How to cite this article: Van Mierlo C, Abegao Pinto L, Stalmans I. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma. J Curr Glaucoma Pract 2015;9(1):28-32.

  20. High resolution OCT quantitative analysis of the space between the IOL and the posterior capsule during the early cataract postoperative period.

    PubMed

    Tao, Aizhu; Lu, Ping; Li, Jin; Shao, Yilei; Wang, Jianhua; Shen, Meixiao; Zhao, Yinying; Lu, Fan

    2013-10-25

    We quantitatively characterized the space between the IOL and the posterior capsule (IOL-PC space) during the early postphacoemulsification period, using high resolution optical coherence tomography (OCT). We recruited 30 eyes of 30 patients who underwent phacoemulsification and randomly divided them into two groups. Acrysof Natural IQ IOLs were implanted in one group (n = 15), and Adapt-AO IOLs were implanted into the other (n = 15). A custom-built OCT instrument was used to image the IOL-PC space at 1 day, 1 week, and 1 month after surgery. Slit-lamp examination and auto refraction were performed at each visit. The IOL-PC spaces in the IQ group were 0.72 ± 0.35, 0.40 ± 0.24, and 0.23 ± 0.16 mm(2) at 1 day, 1 week, and 1 month after surgery, respectively. At each of these times, the values for the AO group were significantly smaller (P < 0.001). Compared to 1 day after surgery, significant changes in the ACDs and refractive errors occurred up to 1 month postoperatively in the IQ group; however, changes in the ACD and refractive error were significant only at 1 week in the AO group. The decreases in IOL-PC space and in ACD during the early postoperative period were associated with a myopic shift. It appeared that the different IOL designs had a role in closure of the IOL-PC space. High resolution OCT was suitable for quantitative analysis of IOL-PC space. (ClinicalTrials.gov number, NCT01605812.).

  1. Improvement of operation voltage and efficiency in inverted blue phosphorescent organic light-emitting devices

    NASA Astrophysics Data System (ADS)

    Chang, Chih-Hao; Huang, Hao Siang; Su, Yu-De; Liang, Yi-Hu; Chang, Yu-Shuo; Chiu, Chuan-Hao; Chang, Hsin-Hua

    2013-09-01

    Inverted organic light-emitting diodes (IOLEDs) have drawn considerable attention for use in active-matrix OLED (AMOLED) displays because of their easy integration with n-channel metal-oxide-based thin film transistors (TFTs). The most crucial issue for IOLEDs is the poor electron injection caused by the bottom cathode. According to previous reports, the turn-on voltages of FIrpic-based IOLEDs are within a range from 4 to 8 V. In this study, we focus on developing bottom-emission IOLEDs with low operating voltages through the use of adequate-charge injection materials. We successfully demonstrate a turn-on voltage as low as 3.7 V for blue phosphorescent IOLEDs. The effective electron injection layers (EIL) were constructed by combining an ultrathin aluminum layer, an alkali metal oxide layer and an organic layer doped with alkali metal oxide, allowing for the effective adjustment of the carrier balance in IOLEDs. The peak efficiencies of the IOLEDs reached 15.6%, 31.8 cd/A and 23.4 lm/W. An external nanocomposite scattering layer was used to further improve light extraction efficiency. The IOLEDs equipped with the SiO2 nanocomposite scattering layer respectively provided performance improvements of 1.3 and 1.5 times that of pristine blue phosphorescent IOLEDs at practical luminance levels of 100 cd/m2 and 1000 cd/m2. Through sophisticated EIL and external light-extraction structures, we obtained blue phosphorescent IOLEDs with satisfactory efficiency and low operation voltages, thereby demonstrating the great potential of nanocomposite film for application in IOLEDs.

  2. Comparison of glare in YAG-damaged intraocular lenses: injection-molded versus lathe-cut.

    PubMed

    Bath, P E; Dang, Y; Martin, W H

    1986-11-01

    A comparative analysis of YAG laser intraocular lens (IOL) damage was undertaken on injection-molded and lathe-cut IOLs. Damage sites were evaluated with polarized light. A consistent positive polarization was observed in the damage sites of lathe-cut IOLs. A consistent negative polarization was observed in the damage sites of injection-molded IOLs. The presence of positive polarization in IOL damage sites may be correlated with increased potential for glare. Results and clinical implications are discussed.

  3. Intra-ocular lens optical changes resulting from the loading of dexamethasone.

    PubMed

    Artigas, José M; García-Domene, M Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo

    2017-10-01

    To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties.

  4. Intra-ocular lens optical changes resulting from the loading of dexamethasone

    PubMed Central

    Artigas, José M.; García-Domene, M. Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo

    2017-01-01

    To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties. PMID:29082089

  5. Rotation stability of a toric intraocular lens with a second capsular tension ring.

    PubMed

    Sagiv, Oded; Sachs, Dan

    2015-05-01

    An Acrysof toric intraocular lens (IOL) and a capsular tension ring (CTR) were implanted in the highly myopic eye of a 74-year-old white man during cataract surgery. On the first postoperative day, the IOL was found 90 degrees from the required position, with a consequent high amount of astigmatism. A second procedure was performed and because it was not possible to secure the toric IOL in the correct position, an additional in-the-bag CTR was inserted, with an immediate optimal outcome. The IOL remained stable up to the final follow-up examination. Co-implantation of a toric IOL and a single CTR has been reported. In our case, 2 CTRs were required to fixate the toric IOL in the correct position. This procedure is simple and safe and should be considered in cases of postoperatively misaligned toric IOLs. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Simulation of 20-year deterioration of acrylic IOLs using severe accelerated deterioration tests.

    PubMed

    Kawai, Kenji; Hayakawa, Kenji; Suzuki, Takahiro

    2012-09-20

    To investigate IOL deterioration by conducting severe accelerated deterioration testing of acrylic IOLs. Department of Ophthalmology, Tokai University School of Medicine Methods: Severe accelerated deterioration tests performed on 7 types of acrylic IOLs simulated 20 years of deterioration. IOLs were placed in a screw tube bottle containing ultra-pure water and kept in an oven (100°C) for 115 days. Deterioration was determined based the outer appearance of the IOL in water and under air-dried conditions using an optical microscope. For accelerated deterioration of polymeric material, the elapse of 115 days was considered to be equivalent to 20 years based on the Arrhenius equation. All of the IOLs in the hydrophobic acrylic group except for AU6 showed glistening-like opacity. The entire optical sections of MA60BM and SA60AT became yellowish white in color. Hydrophilic acrylic IOL HP60M showed no opacity at any of the time points examined. Our data based on accelerated testing showed differences in water content to play a major role in transparency. There were differences in opacity among manufacturers. The method we have used for determining the relative time of IOL deterioration might not represent the exact clinical setting, but the appearance of the materials would presumably be very similar to that seen in patients.

  7. Introduction of Lens-angle Reconstruction Surgery in Rabbit Eyes

    PubMed Central

    Kim, Min Hee; Hwang, Ho Sik; Park, Kyoung Jin; Hwang, Je Hyung

    2014-01-01

    Purpose In this study, we examined the stability of the lens-angle supporter (LAS) for accommodation restoration by comparing intraocular lens (IOL) location, after-cataract and ciliary body damage after cataract surgery in rabbits. Methods Eight rabbits were divided into experimental and control groups of four rabbits each. Phacoemulsification and irrigation and aspiration were performed in all rabbits. This was followed by an LAS and IOL insertion in the four experimental rabbits. In the four control rabbits, only an IOL insertion was performed. Six months after the surgery, the location of the IOL, the conditions of the lens capsule and ciliary body were evaluated using a slitl-amp examination and Miyake-Apple view. Results For the experimental group, the ultrasound biomicroscope results showed normal LAS and IOL positioning in all four cases. According to the slitlamp examination and Miyake-Apple view, the IOL was positioned at the center, with less after-cataract and damage to the ciliary body. For the control group, ultrasound biomicroscope results indicated a higher IOL position than normal, as well as a single case of IOL decentering. According to the slit-lamp examination and Miyake-Apple view, the IOL was decentered with more severe after-cataract and ciliary body damage. Conclusions The LAS has the potential to maintain a stable IOL position while producing less after-cataract when used in lens-angle reconstruction for correction of presbyopia. Moreover, LAS implantation incurs less damage to the ciliary body. PMID:25435752

  8. Development of fibrin-free intraocular lens with photochemical surface modification

    NASA Astrophysics Data System (ADS)

    Sato, Yuji; Tanizawa, Katsuya; Anai, Hiroyuki; Sato, Nobuhiro; Sato, Yuki; Ajiki, Tooru; Parel, Jean-Marie; Murahara, Masataka

    2004-07-01

    Having substituted the hydrophilic and hydrophobic groups alternately on the soft acrylic resin intraocular lens (IOL) surface by using an ArF excimer laser and a Xe2 excimer lamp, we have developed the IOL that is free from fibrin. Acrylic resin or PMMA lens has been used as an intraocular lens for 50 years. However, protein and fat are stuck onto the IOL surface after a long implantation, which opacifies the surface (after-cataract). Thus, we designed the micro domain structures of hydrophilic and hydrophobic groups on the IOL surface for fibrin-free. Firstly, the IOL was irradiated with the Xe2 excimer lamp in the presence of perfluoropolyether in order to make it hydrophobic. By this photochemical reaction, the CF3 functional groups were substituted on the IOL surface. Secondly, the ArF laser was projected on the IOL through the mask pattern in reduced size in the presence of water in order to be hydrophilic. With the photochemical reaction, the OH groups were substituted at the part exposed. The fibrin adsorption test of the modified IOL surface was carried out with FT-IR; which revealed that the fibrin-sticking rate of the treated sample has decreased by 23% compared with that of the non-treated sample. As a result, the fibrin-free IOL has been made by modifying the surface of the IOL to have the micro domain structures of the hydrophilic and hydrophobic groups that are arrayed alternately. In conclusion, the ideal intraocular lens has been demonstrated.

  9. [Macular thickness measured by optical coherence tomography in pseudoaphakic eyes with clear vs yellow implant].

    PubMed

    Chamorro, E; Bonnin-Arias, C; Pérez-Carrasco, M J; Alvarez-Rementería, L; Villa-Collar, C; Armadá-Maresca, F; Sánchez-Ramos, C

    2014-04-01

    To study the use of optical coherence tomography (OCT), for measuring the macular thickness variations produced over time in elderly pseudophakic subjects implanted with a clear intraocular lens (IOL) in one eye, and a yellow IOL in the other eye. Macular thickness measurements were obtained in the 36 eyes of 18 subjects over 65 years, with cataracts surgically removed from both eyes and implanted with different absorbance (clear and yellow) IOLs in 2 separate surgeries. Stratus-OCT was used to determine the macular thickness in 2 sessions with 5 years of difference. After 5 years of follow-up, the eyes implanted with clear IOLs revealed a significant decrease in macular thickness. However, in eyes implanted with yellow IOLs the macular thickness remained stable. The mean overall decrease in macular thickness in eyes implanted with clear IOLs was 5 ± 8 μm (P=.02), and foveal thickness reduction was 10 ± 17 μm (P=.02). The macular thickness changes produced in eyes implanted with a yellow IOL differ from those with a clear IOL. These observation point to a possible protective effect of yellow IOL against the harmful effects of light in elderly pseudophakic subjects. However, studies with a longer follow-up are still needed to confirm that the protection provided by this IOL model is clinically significant. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  10. Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial Keratotomy

    PubMed Central

    Ma, Jack X.; Tang, Maolong; Wang, Li; Weikert, Mitchell P.; Huang, David; Koch, Douglas D.

    2016-01-01

    Purpose To evaluate the accuracy of the optical coherence tomography–based (OCT formula) and Barrett True K (True K) intraocular lens (IOL) calculation formulas in eyes with previous radial keratotomy (RK). Methods In 95 eyes of 65 patients, using the actual refraction following cataract surgery as target refraction, the predicted IOL power for each method was calculated. The IOL prediction error (PE) was obtained by subtracting the predicted IOL power from the implanted IOL power. The arithmetic IOL PE and median refractive PE were calculated and compared. Results All formulas except the True K produced hyperopic IOL PEs at 1 month, which decreased at ≥4 months (all P < 0.05). For the double-K Holladay 1, OCT formula, True K, and average of these three formulas (Average), the median absolute refractive PEs were, respectively, 0.78 diopters (D), 0.74 D, 0.60 D, and 0.59 D at 1 month; 0.69 D, 0.77 D, 0.77 D, and 0.61 D at 2 to 3 months; and 0.34 D, 0.65 D, 0.69 D, and 0.46 D at ≥4 months. The Average produced significantly smaller refractive PE than did the double-K Holladay 1 at 1 month (P < 0.05). There were no significant differences in refractive PEs among formulas at 4 months. Conclusions The OCT formula and True K were comparable to the double-K Holladay 1 method on the ASCRS (American Society of Cataract and Refractive Surgery) calculator. The Average IOL power on the ASCRS calculator may be considered when selecting the IOL power. Further improvements in the accuracy of IOL power calculation in RK eyes are desirable. PMID:27409468

  11. Evaluation of Verisyse and Artiflex phakic intraocular lenses during accommodation using Visante optical coherence tomography.

    PubMed

    Güell, José Luis; Morral, Merce; Gris, Oscar; Gaytan, Javier; Sisquella, Maite; Manero, Felicidad

    2007-08-01

    To perform a dynamic study of the relationship between Verisyse (AMO) and Artiflex (Ophtec B.V.) phakic intraocular lenses (pIOLs) and anterior chamber structures during accommodation using optical coherence tomography (OCT) (Visante, Carl Zeiss Meditec, Inc.) Institutional practice. Eleven myopic patients were randomly selected to have implantation of a Verisyse pIOL in 1 eye and an Artiflex pIOL in the other. Using a 2-dimensional image, dynamic measurements of the relationship between the anterior surface of the pIOL and the corneal endothelium, the posterior surface of the pIOL and the anterior surface of the crystalline lens, and the pupil diameter were performed using Visante OCT. Physiological accommodation was stimulated by adding lenses in 1.00 diopter (D) steps from +1.00 to -7.00 D. Both groups had a significant decrease in pupil diameter (P<.0001, generalized linear model [GLM]) and in the distance between the anterior surface of the pIOL and the corneal endothelium (P<.0001, GLM) with accommodation. There were no statistically significant changes in the distance between the posterior surface of either pIOL and the anterior surface of the crystalline lens (P = .2845, GLM). There were no statistically significant differences between the 2 pIOLs in any measurement (P>.05, GLM). The results fit with Helmholtz' theory of accommodation as forward movement of the diaphragm iris-crystalline lens was seen. There was a decrease in the distance between the pIOL and corneal endothelium and in the pupil diameter, whereas the distance between both pIOLs and the crystalline lens remained constant throughout the accommodation examination. This suggests that the risk for cataract from intermittent contact between the crystalline lens and IOL from accommodative effort is unlikely.

  12. Refractive Outcomes After Femtosecond Laser-Assisted Cataract Surgery in Eyes With Anterior Chamber Phakic Intraocular Lenses.

    PubMed

    Steinwender, Gernot; Shajari, Mehdi; Kohnen, Thomas

    2018-05-01

    To report the efficacy, predictability, and safety of femtosecond laser-assisted cataract surgery (FLACS) in eyes with anterior chamber phakic intraocular lenses (IOLs). This retrospective case series included eyes with previous implantation of an angle-supported and an iris-fixated phakic IOL for the correction of myopia that underwent a combined procedure of phakic IOL ex-plantation and FLACS with in-the-bag implantation of a posterior chamber IOL. Postoperative corrected distance visual acuity (CDVA), predictability of refractive outcome, and occurrence of intraoperative and postoperative complications were analyzed. Ten eyes of 7 patients with significant cataract were included: 5 eyes with an angle-supported foldable hydrophobic phakic IOL, 4 eyes with an angle-supported polymethylmethacrylate (PMMA) phakic IOL, and 1 eye with an iris-fixated PMMA phakic IOL. Mean follow-up after FLACS was 8.4 ± 5.8 months. Mean interval between phakic IOL implantation and FLACS was 11.9 ± 4.0 years. After the combined procedure of phakic IOL explantation and FLACS, mean manifest refractive spherical equivalent (MRSE) was -0.11 ± 0.49 diopters (D) and MRSE was within ± 0.75 D of target refraction in all eyes. Four eyes received a toric posterior chamber IOL after phacoemulsification. Mean preoperative CDVA of 0.40 ± 0.23 logMAR improved significantly to 0.22 ± 0.11 logMAR postoperatively (P = .027). No intraoperative or postoperative complications occurred. The results in this series showed that FLACS in eyes with previous implantation of both rigid and foldable anterior chamber phakic IOLs offers good refractive outcomes with a high level of predictability and safety. [J Refract Surg. 2018;34(5):338-342.]. Copyright 2018, SLACK Incorporated.

  13. Comparison of newer IOL power calculation methods for post-corneal refractive surgery eyes

    PubMed Central

    Wang, Li; Tang, Maolong; Huang, David; Weikert, Mitchell P.; Koch, Douglas D.

    2015-01-01

    Objective To compare the newer formulae, the optical coherence tomography based intraocular lens (IOL) power formula (OCT formula) and the Barrett True-K formula (True-K), to the methods on the ASCRS calculator in eyes with previous myopic LASIK/PRK. Design Prospective case series. Participants One-hundred and four eyes of 80 patients who had previous myopic LASIK/PRK and subsequent cataract surgery and IOL implantation. Methods Using the actual refraction following cataract surgery as target refraction, predicted IOL power for each method was calculated. The IOL prediction error (PE) was obtained by subtracting the predicted IOL power from the power of IOL implanted. Main outcome measures Arithmetic IOL PEs, variances of mean arithmetic IOL PE, median refractive PE and percent of eyes within 0.5 D and 1.0 D of refractive PE. Results OCT produced smaller variance of IOL PE than did Wang-Koch-Maloney, and Shammas (P<0.05). With the OCT, True-K No History, Wang-Koch-Maloney, Shammas, Haigis-L, and Average of these 5 formulas, respectively, the median refractive PEs were 0.35 D, 0.42 D, 0.51 D, 0.48 D, 0.39 D, and 0.35 D, and the % of eyes within 0.5 D of refractive PE were 68.3%, 58.7%, 50.0%, 52.9%, 55.8%, and 67.3%, and within 1.0 D of RPE, 92.3%, 90.4%, 86.9%, 88.5%, 90.4%, and 94.2%, respectively. The OCT formula had smaller refractive PE compared to Wang-Koch-Maloney and Shammas, and the Average approach produced significantly smaller refractive PE than did all methods except OCT (all P<0.05). Conclusions The OCT and True-K No History are promising formulas. The ASCRS IOL calculator has been updated to include the OCT and Barrett True K formulas. Trial registration Intraocular Lens Power Calculation After Laser Refractive Surgery Based on Optical Coherence Tomography (OCT IOL); Identifier: NCT00532051; www.ClinicalTrials.gov PMID:26459996

  14. New trends in intraocular lens imaging

    NASA Astrophysics Data System (ADS)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the eye in near vision. Finally, we present a theoretical approach that considers the modification of less conventional ocular parameters to compensate for possible refractive errors after the IOL implant.

  15. Long-term assessment of tilt of glued intraocular lenses: an optical coherence tomography analysis 5 years after surgery.

    PubMed

    Kumar, Dhivya Ashok; Agarwal, Amar; Agarwal, Athiya; Chandrasekar, Radika; Priyanka, Vijetha

    2015-01-01

    Long-term assessment of the optic position of glued transscleral fixated intraocular lens (IOL) with optical coherence tomography (OCT). Prospective observational case series. Patients with a minimum 5 years' follow-up after glued IOL surgery were included. Postoperatively, IOL position was examined by anterior segment OCT (Carl Zeiss Meditec) and the scans were analyzed in 2 axes (180°-0° and 270°-90°) using MatLab (Mathworks). Best-corrected visual acuity (BCVA; Snellen's charts), Orbscan, retinoscopy, refraction, and slit-lamp biomicroscopy were performed. The distance between the iris margin and the anterior IOL optic (D1, D2), slope of the line across the iris and IOL, the slope ratio between the IOL and iris, IOL tilt, and optic surface changes were determined and correlated with the astigmatism and vision. A total of 60 eyes (mean follow-up of 5.9±0.2 years; range, 5-6 years) were evaluated. There was a significant correlation (P = 0.000) between the slope of iris and the IOL in horizontal and vertical axes. The mean D1 and D2 were 0.94 ± 0.36 and 0.95 ± 0.36 mm, respectively. Nine of 60 eyes (15%) had pigment dispersed on the IOL surface. Twenty-one eyes (35%) had optic tilt detected on OCT and 65% of eyes had no optic tilt. The mean angle between the IOL and the iris was noted to be 3.2 ± 2.7° and 2.9 ± 2.6° in horizontal and vertical axes, respectively. The mean ocular residual astigmatism (ORA) was 0.53 ± 0.5 diopters. There was no difference in the ORA between the eyes with and without tilt (P = 0.762). There was no correlation (P = 0.348) between the ORA and BCVA. Position of the IOL was not dependent on the type of lens, age of the patient, or the preoperative surgical indication. Long-term analysis with OCT demonstrated good IOL positioning without any significant optic tilt in patients with glued IOL fixation. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation: experimental study in pediatric human eyes.

    PubMed

    Pandey, Suresh K; Werner, Liliana; Wilson, M Edward; Izak, Andrea M; Apple, David J

    2004-10-01

    To compare the amount of capsulorhexis ovaling and capsular bag stretch produced by various intraocular lenses (IOLs) implanted in pediatric human eyes obtained post-mortem. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Salt Lake City, Utah, USA. In this nonrandomized comparative study, 16 pediatric human eyes obtained postmortem were divided into 2 groups: Eight eyes were obtained from children younger than 2 years (Group A), and 8 eyes were obtained from children older than 2 years (Group B). All eyes were prepared according to the Miyake-Apple posterior video technique. Six types of rigid and foldable posterior chamber IOLs manufactured from poly(methyl methacrylate) (single-piece), silicone (plate and loop haptics), and hydrophobic acrylic (single-piece and 3-piece AcrySof, Alcon Laboratories) biomaterials were implanted. The capsulorhexis opening and capsular bag diameters were measured before IOL implantation and after in-the-bag IOL fixation with the haptics (or the main axis) at the 3 to 9 o'clock meridian. The percentage of ovaling of the capsulorhexis opening was calculated by noting the difference in the opening's horizontal diameter before and after IOL implantation. The percentage of capsular bag stretch was also calculated by noting the difference in the horizontal capsular bag diameter before and after IOL implantation. All IOLs produced ovaling of the capsulorhexis opening and stretching of the capsular bag parallel to the IOL haptics. There were significant differences in capsulorhexis ovaling and capsular bag stretch (P<.001, analysis of variance) between the 6 IOL types in each group of eyes. The postimplantation difference was significant only between the single-piece hydrophobic acrylic IOL (AcrySof) and the other IOLs. The single-piece hydrophobic acrylic IOL was associated with significantly less capsulorhexis ovaling and capsular bag stretch in both groups (mean 12.06% +/- 0.59% [SD] and 7.6% +/- 1.47%, respectively). Modern rigid and foldable IOLs designed for the adult population implanted in the capsular bag of infants and children produced variable degrees of capsulorhexis ovaling and capsular bag stretch. The Miyake-Apple posterior video technique confirmed the well-maintained configuration of the capsular bag (with minimal ovaling) after implantation of a single-piece hydrophobic acrylic IOL because of its flexible haptic design.

  17. Laser Development for Interferometry in Space

    NASA Technical Reports Server (NTRS)

    Numata, Kenji; Camp, Jordan

    2012-01-01

    We are developing a laser (master oscillator) and optical amplifier for interferometric space missions, including the gravitational-wave missions NGO and OpTIIX experiment on the international space station. Our system is based on optical fiber and semiconductor laser technologies, which have evolved dramatically in the past decade. We will report on the latest status of the development work, including noise measurements and space qualification tests.

  18. Dynamic performance of accommodating intraocular lenses in a negative feedback control system: a simulation-based study.

    PubMed

    Schor, Clifton M; Bharadwaj, Shrikant R; Burns, Christopher D

    2007-07-01

    A dynamic model of ocular accommodation is used to simulate the stability and dynamic performance of accommodating intraocular lenses (A-IOLs) that replace the hardened natural ocular lens that is unable to change focus. Accommodation simulations of an older eye with A-IOL materials having biomechanical properties of a younger eye illustrate overshoots and oscillations resulting from decreased visco-elasticity of the A-IOL. Stable dynamics of an A-IOL are restored by adaptation of phasic and tonic neural-control properties of accommodation. Simulations indicate that neural control must be recalibrated to avoid unstable dynamic accommodation with A-IOLs. An interactive web-model of A-IOL illustrating these properties is available at http://schorlab.berkeley.edu.

  19. Macular protection with IOLs

    NASA Astrophysics Data System (ADS)

    Soderberg, Per G.; Lofgren, Stefan; Ayala, Marcelo; Dong, Xiuqin; Kakar, Manoj; Mody, Vino; Meyer, Linda; Laurell, Carl-Gustaf

    2004-07-01

    The clinical outcome within one month after phacoemulsification cataract extraction with implantation of the blue-blocking SN60AT IOL was examined prospectively and compared to a retrospectively examined material of implantations of the equivalent SA30AL without blue-blocker. There was no difference in best corrected visual acuity gain between the two lenses. In addition, the subjective color perception was examined for with a questionnaire after the first implantation of blue-blocking IOL and after the second implantation of blue-blocking IOL. Only one patient noted a changed color perception. There are thus strong theoretical reasons to block blue light in IOLs and no short term clinical inconvenience. But, it remains to be proven in long term follow up studies that the blue-blocking IOL protects against macular degeneration.

  20. Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power.

    PubMed

    Hayashi, Ken; Manabe, Shin-Ichi; Hayashi, Hideyuki

    2009-12-01

    To compare visual acuity from far to near, contrast visual acuity, and acuity in the presence of glare (glare visual acuity) between an aspheric diffractive multifocal intraocular lens (IOL) with a low addition (add) power (+3.0 diopters) and a monofocal IOL. Hayashi Eye Hospital, Fukuoka, Japan. This prospective study comprised patients having implantation of an aspheric diffractive multifocal ReSTOR SN6AD1 IOL with a +3.0 D add (multifocal group) or a monofocal AcrySof IQ SN60WF IOL (monofocal group). Visual acuity from far to near distances, contrast acuity, and glare acuity were evaluated 3 months postoperatively. Each IOL group comprised 64 eyes of 32 patients. For monocular and binocular visual acuity, the mean uncorrected and distance-corrected intermediate acuity at 0.5 m and the near acuity at 0.3 m were significantly better in the multifocal group than in the monofocal group (P

  1. Final incision size after cataract surgery with toric intraocular lens implantation using 2 techniques.

    PubMed

    Guarnieri, Adriano; Moreno-Montañés, Javier; Sabater, Alfonso L; Gosende-Chico, Inmaculada; Bonet-Farriol, Elvira

    2013-11-01

    To analyze the changes in incision sizes after implantation of a toric intraocular lens (IOL) using 2 methods. Department of Ophthalmology, Clínica Universidad de Navarra, Pamplona, Spain. Prospective case series. Coaxial phacoemulsification and IOL implantation through a 2.2 mm clear corneal incision using a cartridge injector were performed. Wound-assisted or cartridge-insertion techniques were used to implant the IOLs. The results were analyzed according to IOL spherical and cylindrical powers. Corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured and evaluated based on the changes in incision size. Incision size increased in 30 (41.7%) of 72 eyes in the wound-assisted group and 71 (98.6%) of 72 eyes in the cartridge-insertion group. The mean incision size after IOL implantation was 2.27 mm ± 0.06 (SD) and 2.37 ± 0.05 mm, respectively (P<.01). The final incision size and IOL spherical power in the wound-assisted technique group (P=.02) and the cartridge-insertion technique group (P=.03) were correlated significantly; IOL toricity was not (P=.19 and P=.28, respectively). The CH and CRF values were not correlated with the final incision size. The final incision size and the changes in incision size after IOL implantation were greater with the cartridge-insertion technique than with the wound-assisted technique. The increase was related to IOL spherical power in both groups but not to IOL toricity. Corneal biomechanical properties were not correlated with the final incision size. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL.

    PubMed

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José

    2012-02-01

    To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.

  3. Scanning electron microscopic characteristics of commercially available 1- and 3-piece intraocular lenses.

    PubMed

    Brockmann, Tobias; Brockmann, Claudia; Nietzsche, Sandor; Bertelmann, Eckart; Strobel, Juergen; Dawczynski, Jens

    2013-12-01

    To evaluate commercially available 1- and 3-piece intraocular lenses (IOLs) with scanning electron microscopy (SEM). Department of Ophthalmology and Electron Microscopy Center, University Hospital Jena, Jena, Germany. Experimental study. Seven +23.0 diopter IOLs of different design and material and from different manufacturers were chosen for a detailed assessment. Scanning electron microscopy was used at standardized magnifications to assess typical IOL characteristics. The particular focus was the optic edge, the optic surface, the haptic–optic junction, and the haptic. All square-edged IOLs had a curvature radius of less than 10 μm, while the mean optic edge thickness ranged between 216 μm and 382 μm. A 360-degree square-edged boundary was present in all 3-piece IOLs and in a single 1-piece model. Relevant production remnants on the optic edge were observed in 1 case. Regarding the haptic, 3-piece IOLs had uniformly shaped fibers with a mean thickness of 177 μm ± 51 (SD) (range 116 to 220 μm). Chemical adhesives were used to attach the haptic in 1 case, where alterations of the IOL material were observed. In another case, the haptic fiber was press-fitted into the optic, which resulted in bulging of the optic profile. Inspection of surface characteristics showed wavelike patterns in 2 IOLs. Taking clinical relevance into account, all IOLs were of high manufacturing quality. Certain attention was paid in creating a sharp optic edge. Surface irregularities of 2 IOLs were attributed to the manufacturing technique. Methods for implementing the haptic–optic junction were diverse.

  4. Modelling lifetime cost consequences of toric compared with standard IOLs in cataract surgery of astigmatic patients in four European countries.

    PubMed

    Laurendeau, C; Lafuma, A; Berdeaux, G

    2009-09-01

    To compare the lifetime costs of freeing astigmatic patients from spectacles after bilateral cataract surgery implanting toric intraocular lenses (IOLs: i.e., Acrysof Toric) versus monofocal IOLs, in France, Italy, Germany and Spain. A Markov model followed patient cohorts from cataract surgery until death. Prevalence rates of patients not needing spectacles and the types of spectacles prescribed for those requiring them were obtained from clinical trials and national surveys. The economic perspective was societal. Mortality rates were incorporated into the model. Discount rates were applied. A sensitivity analysis was performed on non-discounted costs. Fewer patients with toric IOLs needed spectacles for distance vision than patients with monofocal IOLs. With monofocal IOLs more than 66% of patients needed complex spectacles compared to less than 25% implanted with toric IOLs. In France and Italy, toric IOLs reduced overall costs relative to otherwise high spectacle costs after cataract surgery. Savings were 897.0 euros (France), 822.5 euros (Germany), 895.8 euros (Italy) and 391.6 euros (Spain), without discounting. On applying a 3% discount rate the costs became 691.7 euros, 646.4 euros, 693.9 euros and 308.2 euros, respectively. Bilateral toric IOL implants in astigmatic patients decreased spectacle dependence for distance vision and the need for complex spectacles. The economic consequences for patients depended on the national spectacle costs usually incurred after cataract surgery.

  5. Foot clearance and variability in mono- and multifocal intraocular lens users during stair navigation.

    PubMed

    Renz, Erik; Hackney, Madeleine; Hall, Courtney

    2016-01-01

    Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.

  6. [Miyake-Apple video analysis of movement patterns of an accommodative intraocular lens implant].

    PubMed

    Auffarth, G U; Schmidbauer, J; Becker, K A; Rabsilber, T M; Apple, D J

    2002-11-01

    The potentially accommodative intraocular lens (IOL) is a new development in IOL design We evaluated the new Humanoptics 1CU accommodative IOL in a laboratory study with human post mortem autopsy eyes. Using the Miyake-Apple posterior view video technique, the movement pattern of the IOL was tested and observed from the posterior perspective. RESULTS. A circular bend at the level of the ciliary body applied slight circular force onto the sclera allowing the relaxation of the zonules. The shift of focus was demonstrated by using a reading target. In addition, viscoelastic was injected into the vitreous resulting in the same anterior movement of the IOL optic. The 1CU Humanoptics accommodative IOL showed potential accommodative behaviour in the laboratory. The accommodative (respectively pseudoaccommodative) effect was based on the anterior shift principle with anterior movement of the IOL-optic in the state of relaxing zonules. Whether this reflects the clinical situation, especially to this extent, must be further evaluated.

  7. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag.

    PubMed

    Kohnen, Thomas; Kook, Daniel

    2009-08-01

    We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.

  8. Comparison of contact lens and intraocular lens correction of monocular aphakia during infancy: a randomized clinical trial of HOTV optotype acuity at age 4.5 years and clinical findings at age 5 years.

    PubMed

    Lambert, Scott R; Lynn, Michael J; Hartmann, E Eugenie; DuBois, Lindreth; Drews-Botsch, Carolyn; Freedman, Sharon F; Plager, David A; Buckley, Edward G; Wilson, M Edward

    2014-06-01

    The efficacy and safety of primary intraocular lens (IOL) implantation during early infancy is unknown. To compare the visual outcomes of patients optically corrected with contact lenses vs IOLs following unilateral cataract surgery during early infancy. The Infant Aphakia Treatment Study is a randomized clinical trial with 5 years of follow-up that involved 114 infants with unilateral congenital cataracts at 12 sites. A traveling examiner assessed visual acuity at age 4.5 years. Cataract surgery with or without primary IOL implantation. Contact lenses were used to correct aphakia in patients who did not receive IOLs. Treatment was determined through random assignment. HOTV optotype visual acuity at 4.5 years of age. The median logMAR visual acuity was not significantly different between the treated eyes in the 2 treatment groups (both, 0.90 [20/159]; P = .54). About 50% of treated eyes in both groups had visual acuity less than or equal to 20/200. Significantly more patients in the IOL group had at least 1 adverse event after cataract surgery (contact lens, 56%; IOL, 81%; P = .02). The most common adverse events in the IOL group were lens reproliferation into the visual axis, pupillary membranes, and corectopia. Glaucoma/glaucoma suspect occurred in 35% of treated eyes in the contact lens group vs 28% of eyes in the IOL group (P = .55). Since the initial cataract surgery, significantly more patients in the IOL group have had at least 1 additional intraocular surgery (contact lens, 21%; IOL, 72%; P < .001). There was no significant difference between the median visual acuity of operated eyes in children who underwent primary IOL implantation and those left aphakic. However, there were significantly more adverse events and additional intraoperative procedures in the IOL group. When operating on an infant younger than 7 months of age with a unilateral cataract, we recommend leaving the eye aphakic and focusing the eye with a contact lens. Primary IOL implantation should be reserved for those infants where, in the opinion of the surgeon, the cost and handling of a contact lens would be so burdensome as to result in significant periods of uncorrected aphakia. clinicaltrials.gov Identifier: NCT00212134

  9. Comparison of Biofilm Formation Capacities of Two Clinical Isolates of Staphylococcus Epidermidis with and without icaA and icaD Genes on Intraocular Lenses.

    PubMed

    Kıvanç, Sertaç Argun; Kıvanç, Merih; Kılıç, Volkan; Güllülü, Gülay; Özmen, Ahmet Tuncer

    2017-04-01

    To compare biofilm formations of two Staphylococcus epidermidis (S. epidermidis) isolates with known biofilm formation capacities on four different intraocular lenses (IOL) that have not been studied before. Two isolates obtained from ocular surfaces and identified in previous studies and stored at -86 °C in 15% glycerol in the microbiology laboratory of the Anadolu University Department of Biology were purified and used in the study. The isolates were S. epidermidis KA 15.8 (ICA+), a known biofilm producer isolate positive for icaA, icaD and bap genes, and S. epidermidis KA 14.5 (ICA-), known as a non-biofilm producer isolate negative for icaA, icaD and bap genes. The biofilm formation capacities of the 2 isolates on 4 different IOLs were compared. Two of the IOLs were acrylic (UD613 [IOL A], Turkey; SA60AT [IOL B], USA), and the other two were polymethyl methacrylate (PMMA) (B60130C [IOL C], India; B55125C [IOL D], India). Bacterial enumeration and optical density measurements were done from biofilms that formed on the IOLs. Biofilms were imaged using scanning electron microscopy. Mean bacterial counts on the IOLs were 7.1±0.4 log 10 CFU/mL with the ICA+ isolate, and 6.7±0.8 log 10 CFU/mL with the ICA- isolate; there were no statistically significant differences. Biofilm formation was lower with acrylic lenses than PMMA lenses with both isolates (p=0.009 and p=0.013). The highest biofilm production was obtained on IOL C (PMMA) (p<0.001) and the lowest was obtained on IOL A (hydrophilic acrylic) (p<0.001). Bacterial counts after biofilm formation were lower on acrylic lenses, especially hydrophilic acrylic with hydrophobic properties. Further animal and in vivo studies are required to support the findings of this study.

  10. Light-distortion analysis as a possible indicator of visual quality after refractive lens exchange with diffractive multifocal intraocular lenses.

    PubMed

    Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel

    2015-03-01

    To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P = .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Intraoperative Physical Examination for Diagnosis of Interosseous Ligament Rupture-Cadaveric Study.

    PubMed

    Kachooei, Amir Reza; Rivlin, Michael; Wu, Fei; Faghfouri, Aram; Eberlin, Kyle R; Ring, David

    2015-09-01

    To study the intraobserver and interobserver reliability of the diagnosis of interosseous ligament (IOL) rupture in a cadaver model. On 12 fresh frozen cadavers, radial heads were cut using an identical incision and osteotomy. After randomization, the soft tissues of the limbs were divided into 4 groups: both IOL and triangular fibrocartilage (TFCC) intact; IOL disruption but TFCC intact; both IOL and TFCC divided; and IOL intact but TFCC divided. All incisions had identical suturing. After standard instruction and demonstration of radius pull-push and radius lateral pull tests, 10 physician evaluators with different levels of experience examined the cadaver limbs in a standardized way (elbow at 90° with the forearm held in both supination and pronation) and were asked to classify them into one of the 4 groups. Next, the same examiners were asked to re-examine the limbs after randomly changing the order of examination. The interobserver reliability of agreement for the diagnosis of IOL injury (groups 2 and 3) was fair in both rounds of examination and the intraobserver reliability was moderate. The intra- and interobserver reliabilities of agreement for the 4 groups of injuries among the examiners were fair in both rounds of examination. The sensitivity, specificity, accuracy, positive, and negative predictive values were all around 70%. The likelihood of a positive test corresponding with the presence of IOL rupture (positive likelihood ratio) was 2.2. The likelihood of a negative test correctly diagnosing an intact IOL was 0.40. In cadavers, intraoperative tests had fair reliability and 70% accuracy for the diagnosis of IOL rupture using the push-pull and lateral pull maneuvers. The level of experience did not have any effect on the correct diagnosis of intact versus disrupted IOL. Although not common, some failure of surgeries for traumatic elbow fracture-dislocations is because of failure in timely diagnosis of IOL disruption. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Comparison of Biofilm Formation Capacities of Two Clinical Isolates of Staphylococcus Epidermidis with and without icaA and icaD Genes on Intraocular Lenses

    PubMed Central

    Kıvanç, Sertaç Argun; Kıvanç, Merih; Kılıç, Volkan; Güllülü, Gülay; Özmen, Ahmet Tuncer

    2017-01-01

    Objectives: To compare biofilm formations of two Staphylococcus epidermidis (S. epidermidis) isolates with known biofilm formation capacities on four different intraocular lenses (IOL) that have not been studied before. Materials and Methods: Two isolates obtained from ocular surfaces and identified in previous studies and stored at -86 °C in 15% glycerol in the microbiology laboratory of the Anadolu University Department of Biology were purified and used in the study. The isolates were S. epidermidis KA 15.8 (ICA+), a known biofilm producer isolate positive for icaA, icaD and bap genes, and S. epidermidis KA 14.5 (ICA-), known as a non-biofilm producer isolate negative for icaA, icaD and bap genes. The biofilm formation capacities of the 2 isolates on 4 different IOLs were compared. Two of the IOLs were acrylic (UD613 [IOL A], Turkey; SA60AT [IOL B], USA), and the other two were polymethyl methacrylate (PMMA) (B60130C [IOL C], India; B55125C [IOL D], India). Bacterial enumeration and optical density measurements were done from biofilms that formed on the IOLs. Biofilms were imaged using scanning electron microscopy. Results: Mean bacterial counts on the IOLs were 7.1±0.4 log10 CFU/mL with the ICA+ isolate, and 6.7±0.8 log10 CFU/mL with the ICA- isolate; there were no statistically significant differences. Biofilm formation was lower with acrylic lenses than PMMA lenses with both isolates (p=0.009 and p=0.013). The highest biofilm production was obtained on IOL C (PMMA) (p<0.001) and the lowest was obtained on IOL A (hydrophilic acrylic) (p<0.001). Conclusion: Bacterial counts after biofilm formation were lower on acrylic lenses, especially hydrophilic acrylic with hydrophobic properties. Further animal and in vivo studies are required to support the findings of this study. PMID:28405479

  13. An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device.

    PubMed

    Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S

    2017-08-01

    This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.

  14. Comparison of toric intraocular lenses and peripheral corneal relaxing incisions to treat astigmatism during cataract surgery.

    PubMed

    Mingo-Botín, David; Muñoz-Negrete, Francisco José; Won Kim, Hae Ryung; Morcillo-Laiz, Rafael; Rebolleda, Gema; Oblanca, Noelia

    2010-10-01

    To evaluate and compare toric intraocular lens (IOL) implantation and spherical IOL implantation with peripheral corneal relaxing incisions to manage astigmatism during phacoemulsification. Ophthalmology Service, Hospital Ramón y Cajal, Madrid, Spain. Prospective randomized comparative case series. Eyes with cataract and corneal astigmatism (1.00 to 3.00 diopters [D]) had toric IOL implantation or peripheral corneal relaxing incisions. Outcome measures were visual outcomes, slitlamp assessment, digital toric IOL axis determination, spectacle need, and patient satisfaction. Three months postoperatively, the mean uncorrected distance visual acuity (UDVA) was 0.13 ± 0.10 (SD) in the toric IOL group and 0.19 ± 0.12 in the relaxing incisions group; the UDVA was better than 0.20 in 75% of eyes and 60% of eyes, respectively. Refractive cylinder decreased significantly in both groups, with a mean residual refractive astigmatism of 0.61 ± 0.41 D in the toric IOL group and 1.32 ± 0.60 D in the relaxing incisions group (P<.01). The mean toric IOL rotation was 3.65 ± 2.96 degrees, with no significant differences between slitlamp and digital photograph measurements. There was a trend toward better mesopic contrast sensitivity with glare in the toric IOL group. There were no differences in VF-14 or patient satisfaction results; 15% of patients in the toric IOL group and 45% in the relaxing-incision group required distance spectacles postoperatively. Although refractive astigmatism decreased in both groups, toric IOL implantation was more effective and predictable, resulting in greater spectacle independence. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Economic considerations related to choice of intraocular lens (IOL) and posterior capsule opacification frequency - a comparison of three different IOLs.

    PubMed

    Cullin, Felix; Busch, Tobias; Lundström, Mats

    2014-03-01

    To evaluate the posterior capsule opacification (PCO) rates in three different modern standard intraocular lenses (IOL) and analyse the related cost. Retrospective study of medical records from 1527 patients who underwent uneventful cataract surgery by phacoemulsification with posterior chamber implantation of either AcrySof SN60 (n = 375), Akreos Adapt (n = 350) or Tecnis Acryl IOL (n = 801). All surgeries were performed by the same surgeon using the same surgical technique and equipment. Primary end-point was neodymium:yttrium-aluminium-garnet (Nd:YAG) capsulotomy for visual impairment secondary to PCO. Cost of IOL material and Nd:YAG capsulotomy for PCO was then evaluated and compared between the IOLs. Mean follow-up was 41.5 months, and the only statistically significant variable of developing PCO was IOL type and individual follow-up time. Nd:YAG capsulotomy was performed in 7.47% in the AcrySof group, 17.71% in the Akreos group and 3.75% in the Tecnis group. Average cost for Nd:YAG capsulotomy per surgery was €18.75 in the AcrySof SN60 group, €44.25 in the Akreos Adapt group and €9.25 in the Tecnis Acryl group. The combined cost of cataract surgery and PCO treatment was €9.81 higher in for the Akreos Adapt group than the other two combined. This retrospective study shows that the risk of PCO and Nd:YAG capsulotomy is significantly higher in hydrophilic Akreos IOL compared with both AcrySof and Tecnis hydrophobic IOLs. The increased risk of PCO in the hydrophilic IOL is related to higher total average costs for cataract surgery. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  16. Lifetime costs and effectiveness of ReSTOR compared with a monofocal IOL and Array-SA40 in the Netherlands.

    PubMed

    De Vries, N E; Laurendeau, C; Lafuma, A; Berdeaux, G; Nuijts, R M M A

    2010-04-01

    To estimate the lifetime cost consequences for society and the National Health Service (NHS) of bilateral monofocal (SI40NB) or multifocal (ReSTOR or Array-SA40) intraocular lense (IOL) implantation after cataract surgery. Public hospital in the Netherlands. A Markov model simulated three cohorts of patients followed 69 until 100 years of age, or death. Spectacle independence rates for each IOL were adjusted to the results of a randomized clinical trial that compared monofocal and multifocal Array-SA40 IOL implants, together with a prospective cohort of patients implanted with ReSTOR. Adjustment was performed using the propensity score method in a multivariate analysis. Resource consumption was estimated from a dedicated Dutch survey. Dutch unit costs were applied to spectacles, cataract surgery, IOLs, visits to ophthalmologists, optometrists, transport, and spectacle cleaning materials. Cost discounted at 4% and undiscounted economic results were calculated. Spectacle independence rates were 86.0% for ReSTOR, 8.7% for monofocal IOLs, and 8.5% for Array-SA40. Patients lived without needing spectacles for 12.9 years after ReSTOR, for 1.4 years after monofocal IOLs, and 1.3 years after Array-SA40. ReSTOR patients bought 6.4 fewer pairs of spectacles than monofocal patients. Lifetime discounted cost consequences for the society were ReSTOR euro3969, monofocal IOLs euro4123, and Array-SA40 euro5326. Corresponding costs for the NHS were euro2415, euro2555, and euro2556, respectively. ReSTOR IOLs provided higher levels of spectacle independence than monofocal SI40NB or multifocal Array-SA40 IOLs resulting in savings, compared to a monofocal, over the period modelled of euro315 for society and euro140 for the NHS.

  17. Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery.

    PubMed

    Camps, Vicente J; Miret, Juan J; García, Celia; Tolosa, Angel; Piñero, David P

    2018-04-01

    To simulate the optical performance of three presbyopia-correcting intraocular lenses (IOLs) implanted in eyes with previous laser refractive surgery. A simulation of the through-focus modulation transfer function (MTF) was performed for three presbyopia-correcting IOLs (Mplus, Oculentis GmbH, Berlin, Germany; Symfony, Johnson & Johnson Vision, Santa Ana, CA; and Mini Well, SIFI S.p.A., Lavinaio, Italy) in one eye with previous myopic LASIK and another with hyperopic LASIK. Real topographic data and the wavefront aberration profile of each IOL obtained with a Hartmann-Shack sensor were used. In the eye with myopic LASIK, all IOLs lost optical quality at near and intermediate distances for 4- and 4.7-mm pupil size. For 3-mm pupil size, the Mini Well IOL showed the best intermediate and near MTF and maintained the far focus independently of the pupil. In the eye with hyperopic LASIK, the Mini Well IOL showed an intermediate, distance, and -4.00-diopter (D) foci for all pupils. The Symfony IOL showed a depth of focus at far and intermediate distance for 3-mm and a focus at -2.50 D in the rest. The Mplus showed a focus of -4.50 and -3.00 D for the 3- and 4-mm pupil, respectively. The Mini Well and Symfony IOLs seem to work better than the Mplus IOL in eyes with previous myopic LASIK. With previous hyperopic LASIK, the Mini Well IOL seems to be able to provide acceptable near, intermediate, and far foci for all pupil sizes. These findings should be confirmed in future clinical studies. [J Refract Surg. 2018;34(4):222-227.]. Copyright 2018, SLACK Incorporated.

  18. High-performance flexible inverted organic light-emitting diodes by exploiting MoS2 nanopillar arrays as electron-injecting and light-coupling layers.

    PubMed

    Guo, Kunping; Si, Changfeng; Han, Ceng; Pan, Saihu; Chen, Guo; Zheng, Yanqiong; Zhu, Wenqing; Zhang, Jianhua; Sun, Chang; Wei, Bin

    2017-10-05

    Inverted organic light-emitting diodes (IOLEDs) on plastic substrates have great potential application in flexible active-matrix displays. High energy consumption, instability and poor electron injection are key issues limiting the commercialization of flexible IOLEDs. Here, we have systematically investigated the electrooptical properties of molybdenum disulfide (MoS 2 ) and applied it in developing highly efficient and stable blue fluorescent IOLEDs. We have demonstrated that MoS 2 -based IOLEDs can significantly improve electron-injecting capacity. For the MoS 2 -based device on plastic substrates, we have achieved a very high external quantum efficiency of 7.3% at the luminance of 9141 cd m -2 , which is the highest among the flexible blue fluorescent IOLEDs reported. Also, an approximately 1.8-fold improvement in power efficiency was obtained compared to glass-based IOLEDs. We attributed the enhanced performance of flexible IOLEDs to MoS 2 nanopillar arrays due to their light extraction effect. The van der Waals force played an important role in the formation of MoS 2 nanopillar arrays by thermal evaporation. Notably, MoS 2 -based flexible IOLEDs exhibit an intriguing efficiency roll-up, that is, the current efficiency increases slightly from 14.0 to 14.6 cd A -1 with the luminance increasing from 100 to 5000 cd m -2 . In addition, we observed that the initial brightness of 500 cd m -2 can be maintained at 97% after bending for 500 cycles, demonstrating the excellent mechanical stability of flexible IOLEDs. Furthermore, we have successfully fabricated a transparent, flexible IOLED with low efficiency roll-off at high current density.

  19. Evaluation of the quality of generic polymethylmethacrylate intraocular lenses marketed in India.

    PubMed

    Combe, R; Watkins, R; Brian, G

    2001-04-01

    To determine the quality of single-piece, allpolymethylmethacrylate (PMMA) Intraocular lenses (IOLs) from eght generic manufacturers marketing their product in India. This assessment of quality was made with respect to compliance with internationa standards for the manufacture of IOLs, specifically those parameters most likely to affect patient postoperat ve visual acuity and the long-term biocompatibility of the implanted lens. Ten IOLs from each of eight manufacturers were purchased randomly from commercial retail outlets in India. Each IOL, in a masked fashion, had its physical dimensions, optical performance and cosmetic appearance assessed, using the methods prescribed in ISO 11979-2 and 11979-3. Validation of manufacturing process controls were determined by statistical process contro techniques. Four IOLs from each manufacturer were also tested for the presence of unpolymerized PMMA using gas chromatography. Only lenses from two IOL manufacturers complied with the optical and mechanical standards. All other manufacturers' lenses failed one or more of these tests. Intraocular lenses from only two producers met with surface quality and bulk homogeneity standards. All others exhibited defects such as surface contamination and scratches, poor polishing, and chipped or rough positioning holes. Lenses from two producers exhibited high levels of methylmethacrylate monomer (MMA). Non-clinical grade PMMA starting material may have been used in the manufacture of IOLs by some producers. Critical manufacturing defects occurred in the IOLs from five of the eight producers tested. Only one manufacturer's IOLs met all specifications, and on statistical analysis demonstrated good manufacturing process contro with respect to the properties tested. With the widespread acceptance of IOL implantation in developing countries, such as India, it is essential that in the rush to make this the norm, the quality of implants used not be overlooked.

  20. Is the Capsular Bag Perimeter Round or Elliptical?

    PubMed Central

    Amigó, Alfredo; Bonaque-González, Sergio

    2016-01-01

    Purpose: To report findings that could suggest an elliptical shape of the capsular bag. Methods: Five eyes of three patients with axial length greater than 24 mm underwent phacoemulsification cataract surgery with plate-haptic multifocal toric intraocular lens (IOL) implantation oriented in the vertical meridian. Results: In all cases, correct orientation of the IOLs was verified 30 minutes after surgery. After 24 hours, all eyes demonstrated unwanted rotation of the IOLs ranging from 15 to 45 degrees. The IOLs remained stable in the new position in all cases until adhesion of the capsular bag took place. Conclusion: These observations could suggest that the perimeter of the capsular bag has an elliptical shape. Therefore, the IOL tends to become fixated in a meridian of the capsular bag that best fits the diagonal diameter of the IOL. PMID:27413495

  1. Recurrent uveitis and pigment dispersion in an eye with in-the-bag acrylic foldable intraocular lens.

    PubMed

    Thakur, Monica; Bhatia, Prashant; Chandrasekhar, Garudadri; Senthil, Sirisha

    2016-02-26

    Phacoemulsification with in-the-bag intraocular lens (IOL) implantation is the standard procedure for cataract surgery. Pigment dispersion and uveitis can result when an IOL is placed in the sulcus. We report a case of a 64-year-old woman, with pigmentary glaucoma, who developed recurrent uveitis following uneventful cataract surgery and an in-the-bag hydrophobic acrylic IOL implant. Recurrent uveitis did not subside despite use of topical steroids over 3 months. Dilated examination revealed capsulophimosis with anterior dislocation of the IOL haptic. The mechanical trauma to the iris due to the displaced haptic was implicated as the cause of recurrent uveitis, which completely resolved after capsular excision and IOL repositioning. This case illustrates a rare cause of recurrent uveitis due to IOL haptic dislocation following severe capsulophimosis. 2016 BMJ Publishing Group Ltd.

  2. Correction of low corneal astigmatism in cataract surgery.

    PubMed

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.

  3. Correction of low corneal astigmatism in cataract surgery

    PubMed Central

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    AIM To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. METHODS A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. RESULTS The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. CONCLUSION The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision. PMID:26309869

  4. Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses

    PubMed Central

    Hayashi, K.; Hayashi, H.; Nakao, F.; Hayashi, F.

    1998-01-01

    BACKGROUND—The extent of the decentration and tilt was prospectively compared between one piece polymethyl methacrylate (PMMA) and three piece PMMA intraocular lenses (IOLs) which were implanted in the capsular bag after performing continuous curvilinear capsulorhexis.
METHODS—91 patients underwent a one piece PMMA IOL implantation in one eye as well as the implantation of the three piece PMMA IOL with polyvinylidene fluoride loops in the opposite eye. The length of the lens decentration and the angle of the tilt were quantitated using the anterior eye segment analysis system (EAS-1000) at 1 week as well as 1, 3, and 6 months postoperatively.
RESULTS—The mean length of the decentration in the one piece IOL was smaller than that in the three piece IOL at 1 week (p=0.0092), 1 month (p=0.0044), 3 months (p=0.0069), and 6 months (p=0.0010) postoperatively. However, no significant difference was found in the degree of the tilt between the two types of IOLs throughout the observation periods.
CONCLUSION—These results clarified that the one piece PMMA IOL with rigid PMMA haptics implanted in the capsular bag provides a better centration than the three piece PMMA IOL with flexible haptics, whereas the tilt was the same between the two types of IOLs.

 Keywords: intraocular lens; decentration; tilt; continuous curvilinear capsulorhexis PMID:9640193

  5. The effect of cataract surgery on sleep quality: a systematic review and Meta-analysis

    PubMed Central

    Zheng, Ling; Wu, Xiao-Hang; Lin, Hao-Tian

    2017-01-01

    AIM To evaluate the effect of cataract surgery on sleep quality and to compare the difference between ultraviolet-blocking clear intraocular lens (UVB-IOL) and blue-filtering intraocular lens (BF-IOL) implantation. METHODS Electronic search was performed of PubMed, MEDLINE, Embase and the Cochrane Library up to January 2016. Studies were eligible when they evaluated the sleep quality before and after cataract surgery by Pittsburgh sleep quality index (PSQI). A random/fixed-effects Meta-analysis was used for the pooled estimate. Heterogeneity was assessed with the I2 test. RESULTS Six studies were selected from 5623 references. Cataract surgery significantly reduced the PSQI scores at postoperative 0-3mo [mean difference (MD) =-0.62, 95%CI: -1.14 to -0.11, P=0.02, I2=66%] and 3-12mo (MD=-0.32, 95%CI: -0.62 to -0.02, P=0.04, I2=0), respectively. Considering different intraocular lens (IOL) implantations, relative post-operative PSQI reduction was found for both UVB-IOL and BF-IOL, but a significant reduction was detected only for UVB-IOL. No significant difference was found with the effect of BF-IOL vs UVB-IOL on sleep quality. CONCLUSION This study found that cataract surgery significantly improved the PSQI score-derived subjective sleep quality irrespective of the IOL type implanted. These findings highlight a substantial benefit of cataract surgery on systemic health with photoreceptive restoration in addition to visual acuity improvements. PMID:29181319

  6. The Enigmatic Cornea and Intraocular Lens Calculations: The LXXIII Edward Jackson Memorial Lecture.

    PubMed

    Koch, Douglas D

    2016-11-01

    To review the progress and challenges in obtaining accurate corneal power measurements for intraocular lens (IOL) calculations. Personal perspective, review of literature, case presentations, and personal data. Through literature review findings, case presentations, and data from the author's center, the types of corneal measurement errors that can occur in IOL calculation are categorized and described, along with discussion of future options to improve accuracy. Advances in IOL calculation technology and formulas have greatly increased the accuracy of IOL calculations. Recent reports suggest that over 90% of normal eyes implanted with IOLs may achieve accuracy to within 0.5 diopter (D) of the refractive target. Though errors in estimation of corneal power can cause IOL calculation errors in eyes with normal corneas, greater difficulties in measuring corneal power are encountered in eyes with diseased, scarred, and postsurgical corneas. For these corneas, problematic issues are quantifying anterior corneal power and measuring posterior corneal power and astigmatism. Results in these eyes are improving, but 2 examples illustrate current limitations: (1) spherical accuracy within 0.5 D is achieved in only 70% of eyes with post-refractive surgery corneas, and (2) astigmatism accuracy within 0.5 D is achieved in only 80% of eyes implanted with toric IOLs. Corneal power measurements are a major source of error in IOL calculations. New corneal imaging technology and IOL calculation formulas have improved outcomes and hold the promise of ongoing progress. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Stability and safety of MA50 intraocular lens placed in the sulcus.

    PubMed

    Kemp, P S; Oetting, T A

    2015-11-01

    To describe the safety and stability of sulcus placement of the MA50 intraocular lens (IOL). Consecutive patients with MA50 IOLs placed in the sulcus at the University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA, from 1997 to 2012 were identified. Inclusion criteria included patients with over 4 weeks of follow-up data. AEL was compared with incidence of IOL decentration using at two-tailed Student's t-test. Fifty eyes of 49 patients meeting the inclusion criteria were identified. Four weeks post-operatively, the average best-corrected visual acuity was 20/30. IOL decentration occurred in 14% of patients; patients with decentered IOLs had a significantly longer average AEL (25.37 mm) than patients whose IOL remained centered (23.94 mm, P=0.017). Other complications included uveitis-glaucoma-hyphema syndrome (12%), iritis (8%), and glaucoma (6%). There were no cases of pigment dispersion syndrome or need for lens exchange. Twelve eyes (24%) had intra-operative optic capture by the anterior capsule, none of which had post-operative decentration. The MA50 IOL is a reasonable, stable option for placement in the sulcus, with a low-risk profile; however, in eyes with longer AEL and presumably larger anterior segment, surgeons should consider placing an IOL with longer haptic distance than the MA50 to maintain centration. Optic capture of the MA50 IOL by the anterior capsule should be considered for longer eyes, as it is protective against decentration.

  8. Instrumental studies on silicone oil adsorption to the surface of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Kim, Chun Ho; Joo, Choun-Ki; Chun, Heung Jae; Yoo, Bok Ryul; Noh, Dong Il; Shim, Young Bock

    2012-12-01

    The purpose of this study was to examine the degree of adherence of silicone oil to various intraocular lenses (IOLs) through comparison of the physico-chemical properties of the oil and IOLs. Four kinds of IOLs comprising various biomaterials were examined: PMMA (720A™), PHEMA (IOGEL 1103™), Acrysof (MA60BM™), and silicone (SI30NB™). Each lens was immersed in silicone oil or carboxylated silicone (CS-PDMS) oil for 72 h. For determination of the changes in chemical and elemental compositions on the surfaces of IOLs caused by the contact with silicone oil, IOLs were washed and rinsed with n-pentane to remove as much of the adsorbed silicone oil as possible, then subjected to Fourier transform infrared spectroscopic (FTIR) and X-ray photoelectron spectroscopic (XPS) analyses. The results of FTIR studies strongly indicate that washing with n-pentane completely removed the adhered silicone oil on the surfaces of PHEMA and Acrysof IOLs, whereas the residual silicone oil was detected on the surfaces of PMMA and silicone IOLs. XPS studies showed that silicone oil coverage of PMMA lenses was 12%, even after washing with n-pentane. In the case of silicone IOLs, the relative O1s peak area of carboxyl group in the residual CS-PDMS oil was found to be ˜2.7%. Considering that 2.8% carboxyl group-substituted silicone oil was used in the present study, CS-PDMS oil covered the entire surface of the silicone IOLs.

  9. New Hydrophobic IOL Materials and Understanding the Science of Glistenings.

    PubMed

    Tetz, Manfred; Jorgensen, Matthew R

    2015-01-01

    An introduction to the history of intraocular lenses (IOLs) is given, leading up to modern hydrophobic examples. The roles of hydrophobicity, hygroscopy, materials chemistry, and edge design are discussed in the context of IOLs. The four major types of IOL materials are compared in terms of their chemistry and biocompatibility. An example of a modern "hydrophobic" acrylic polymer with higher water content is discussed in detail.

  10. Improved PMMA single-piece haptic materials

    NASA Astrophysics Data System (ADS)

    Healy, Donald D.; Wilcox, Christopher D.

    1991-12-01

    During the past fifteen years, Intraocular lens (IOL) haptic preferences have shifted from a variety of multi-piece haptic materials to single-piece PMMA. This is due in part to the research of David Apple, M.D., and other who have suggested that All-PMMA implants result in reduced cell flare and better centration. Consequently, single-piece IOLs now represent 45% of all IOL implants. However, many surgeons regard single-piece IOL designs as nonflexible and more difficult to implant than multipiece IOLs. These handling characteristics have slowed the shift from multi-piece to single-piece IOLs. As a result of these handling characteristics, single-piece lenses experience relatively high breakage rates because of handling before insertion and during insertion. To improve these characteristics, manufacturers have refined single-piece IOL haptic designs by pushing the limits of PMMA's physical properties. Furthermore, IOL manufacturers have begun to alter the material itself to change its physical properties. In particular, two new PMMA materials have emerged in the marketplace: Flexeon trademark, a crosslinked polymer and CM trademark, a material with molecularly realigned PMMA. This paper examines three specific measurements of a haptic's strength and flexibility: tensile strength, plastic memory and material plasticity/elasticity. The paper compares with Flexeon trademark and CM trademark lenses to noncrosslinked one-piece lenses and standard polypropylene multi-piece lenses.

  11. Improvement of Uveal and Capsular Biocompatibility of Hydrophobic Acrylic Intraocular Lens by Surface Grafting with 2-Methacryloyloxyethyl Phosphorylcholine-Methacrylic Acid Copolymer

    PubMed Central

    Tan, Xuhua; Zhan, Jiezhao; Zhu, Yi; Cao, Ji; Wang, Lin; Liu, Sa; Wang, Yingjun; Liu, Zhenzhen; Qin, Yingyan; Wu, Mingxing; Liu, Yizhi; Ren, Li

    2017-01-01

    Biocompatibility of intraocular lens (IOL) is critical to vision reconstruction after cataract surgery. Foldable hydrophobic acrylic IOL is vulnerable to the adhesion of extracellular matrix proteins and cells, leading to increased incidence of postoperative inflammation and capsule opacification. To increase IOL biocompatibility, we synthesized a hydrophilic copolymer P(MPC-MAA) and grafted the copolymer onto the surface of IOL through air plasma treatment. X-ray photoelectron spectroscopy, atomic force microscopy and static water contact angle were used to characterize chemical changes, topography and hydrophilicity of the IOL surface, respectively. Quartz crystal microbalance with dissipation (QCM-D) showed that P(MPC-MAA) modified IOLs were resistant to protein adsorption. Moreover, P(MPC-MAA) modification inhibited adhesion and proliferation of lens epithelial cells (LECs) in vitro. To analyze uveal and capsular biocompatibility in vivo, we implanted the P(MPC-MAA) modified IOLs into rabbits after phacoemulsification. P(MPC-MAA) modification significantly reduced postoperative inflammation and anterior capsule opacification (ACO), and did not affect posterior capsule opacification (PCO). Collectively, our study suggests that surface modification by P(MPC-MAA) can significantly improve uveal and capsular biocompatibility of hydrophobic acrylic IOL, which could potentially benefit patients with blood-aqueous barrier damage. PMID:28084469

  12. Simple technique to measure toric intraocular lens alignment and stability using a smartphone.

    PubMed

    Teichman, Joshua C; Baig, Kashif; Ahmed, Iqbal Ike K

    2014-12-01

    Toric intraocular lenses (IOLs) are commonly implanted to correct corneal astigmatism at the time of cataract surgery. Their use requires preoperative calculation of the axis of implantation and postoperative measurement to determine whether the IOL has been implanted with the proper orientation. Moreover, toric IOL alignment stability over time is important for the patient and for the longitudinal evaluation of toric IOLs. We present a simple, inexpensive, and precise method to measure the toric IOL axis using a camera-enabled cellular phone (iPhone 5S) and computer software (ImageJ). Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Effect of ophthalmic solution components on acrylic intraocular lenses.

    PubMed

    Ayaki, Masahiko; Nishihara, Hitoshi; Yaguchi, Shigeo; Koide, Ryohei

    2007-01-01

    To investigate the effect of ophthalmic solution components on the surface of acrylic intraocular lenses (IOLs). Department of Opthalmology, Showa University School of Medicine. Measurement of the contact angles of ophthalmic solutions on 3 acrylic IOLs was performed. The solutions were diclofenac sodium (Diclod), bromfenac sodium (Bronuck), betamethasone phosphate (Rinderon), dibekacin sulfate (Panimycin), polysorbate 80 (Tween 20), benzalkonium chloride, chlorobutanol, methylparahydroxybenzoate, and propylparahydroxybenzoate. The IOLs were incubated at 35 degrees C for 2 weeks in undiluted ophthalmic solutions and in 1:10 dilutions of ophthalmic solution components. The IOLs were sectioned and observed by scanning electron microscopy. The contact angle of Diclod and Bronuck solutions was the smallest. The contact angle of Rinderon and Panimycin was similar to that of distilled water. Scanning electron microscopy examination of IOLs incubated in ophthalmic solution components showed intralenticular changes. The IOLs immersed in ophthalmic solutions did not show any change, even after extended incubation. The chemical components of ophthalmic solutions, such as surfactants and solvents, permeate acrylic IOLs, suggesting the potential for long-term adverse effects of eyedrops in pseudophakic eyes.

  14. INTRAOCULAR LENS SCAFFOLD TO PREVENT INTRAOCULAR FOREIGN BODY SLIPPAGE.

    PubMed

    Agarwal, Amar; Ashok Kumar, Dhivya; Agarwal, Athiya

    2017-01-01

    To report the application of intraocular lens (IOL) scaffold technique in intraocular foreign body (IOFB) removal. Patient with IOFB in posterior segment is included. The IOFB is retrieved from the posterior segment (pars plana vitrectomy and exteriorization of the IOFB from the retinal surface using an intravitreal forceps via the posterior capsulotomy) and placed on the iris. A three-piece posterior chamber IOL is placed in the sulcus via the clear corneal incision. IOFB is then removed from the anterior chamber over the IOL by forceps. Metallic IOFB of 4 mm × 3 mm has been retrieved by IOL scaffold technique after rescuing it from the posterior segment. There has been no drop or slip of IOFB in the vitreous during removal. Posterior chamber IOL served as scaffold during IOFB removal from anterior chamber. The IOL scaffold maneuver has shown to prevent slippage by acting as a barrier between the IOFB and the vitreous.

  15. Early opacification and subsequent in vivo clearing of a silicone intraocular lens.

    PubMed

    Nikrooyan, Idean; Anderson, Justin E

    2011-09-01

    To report a case of early opacification and spontaneous in vivo clearing of a silicone intraocular lens (IOL). A 79-year-old women underwent uncomplicated cataract extraction and subsequent implantation of a +21.5 D AMO Z9002 (Abbott Medical Optics, Santa Ana, CA) silicone lens. On postoperative day 1, the patient presented with a translucent, milky white appearing, diffuse IOL opacification. On postoperative day 8, the IOL periphery had cleared, but a full thickness haze persisted in the central portion of the optic. By postoperative day 14, the IOL had cleared. To date, the lens has remained clear. One possible mechanism might be exposure to industrial chemicals; however, the manufacturer reports no other similar lens opacities from this manufacturing batch of IOLs. We recommend that surgeons who implant or have implanted an AMO Z9002 silicone IOL and observe similar findings follow the patient closely for resolution of the haze.

  16. Managing residual refractive error after cataract surgery.

    PubMed

    Sáles, Christopher S; Manche, Edward E

    2015-06-01

    We present a review of keratorefractive and intraocular approaches to managing residual astigmatic and spherical refractive error after cataract surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), arcuate keratotomy, intraocular lens (IOL) exchange, piggyback IOLs, and light-adjustable IOLs. Currently available literature suggests that laser vision correction, whether LASIK or PRK, yields more effective and predictable outcomes than intraocular surgery. Piggyback IOLs with a rounded-edge profile implanted in the sulcus may be superior to IOL exchange, but both options present potential risks that likely outweigh the refractive benefits except in cases with large residual spherical errors. The light-adjustable IOL may provide an ideal treatment to pseudophakic ametropia by obviating the need for secondary invasive procedures after cataract surgery, but it is not widely available nor has it been sufficiently studied. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Complications of cataract and refractive surgery: a clinicopathological documentation.

    PubMed Central

    Apple, D J; Werner, L

    2001-01-01

    PURPOSE: To present selected complications of keratorefractive and phakic intraocular lens (IOL) surgery and a series of IOLs that required explantation because of various postimplantation opacification of the IOL optic. METHODS: Two specimens obtained after keratorefractive surgery, 2 phakic IOLs, and a total of 23 explanted IOLs from cases in which postimplantation opacification of the IOL optic had occurred were studied. These included 6 Bausch and Lomb (B&L) Hydroview H60 M designs, 9 Medical Developmental Research (MDR) SC60B-OUV designs, and 24 IOLs with rigid PMMA optics that had been implanted in the 1980s and early 1990s. Of the latter, 8 required late explantation because of decreased visual acuity. Analyses performed included gross and light microscopic evaluation, histochemical staining, electron microscopy, and energy-dispersive spectroscopy. RESULTS: We provide examples of 3 postrefractive surgery complications: (1) fungal keratitis after LASIK, (2) post-LASIK corneal decompensation, and (3) cataract formation after implantation of phakic posterior chamber IOLs. Regarding the IOL optic opacities, classifications of 3 types are described: (1) a surface calcification of the B&L Hydroview IOL; (2) diffusion of calcium into the substance of the optic of the hydrophilic "acrylic" SC60B-OUV MDR foldable IOL design, sometimes leading to total opacification of the IOL optic and also its haptics; (3) a distinct pattern of intraoptical opacification with rigid PMMA designs that we term a snowflake degeneration. This term is based on the clinical and pathologic appearance of the individual lesions. Each snowflake lesion represents a focal breakdown of PMMA material as opposed to deposition of exogenous material. CONCLUSIONS: Analysis of complications of refractive surgery represents a new field of ocular pathology. The clinicopathological reports presented here provide an overview of selected complications after refractive surgery. We also help define 3 newly recognized, clinically significant conditions based on postoperative IOL optic opacification. The calcification processes noted on the 2 modern foldable designs studied here (B&L and MDR lenses) need further review by the manufacturers in order to reassess production processes, especially in terms of polymer selection, manufacturing techniques, and other factors required to produce a safe and effective lens. Any lens not meeting today's high standards should not be marketed. The important fact in recognizing the snowflake complication of PMMA IOLs as described here is to alert surgeons about the nature of the lesion so that they will not alarm patients or require extensive and unnecessary testing in trying to determine its pathogenesis. There is no reason why successful explantation cannot be performed in cases where severe visual decrease or loss has occurred. PMID:11797325

  18. Spherotoric bag-in-the-lens intraocular lens: power calculation and predictive misalignment nomogram.

    PubMed

    Gobin, Laure; Tassignon, Marie-José; Mathysen, Danny

    2011-06-01

    To propose a method of calculating the power of the 1-sided posterior chamber toric bag-in-the-lens (BIL) intraocular lens (IOL) and propose a misalignment nomogram to calculate the postoperative rotational misalignment or predict the effect of preoperative existing irregular corneal astigmatism. Antwerp University Hospital, Department of Ophthalmology, Antwerp, Belgium. Cohort study. The new IOL calculation formula uses the steepest corneal meridian and flattest corneal meridian separately (regular spherical IOL formula) followed by a customized A-constant approach based on the changes in the IOL principal plane depending on the spherical and cylindrical powers (thickness) of the IOL. The calculation of the remaining astigmatism (power and axis) in cases of postoperative rotational misalignment resulted in a nomogram that can also be used to predict the degree of tolerance for irregular corneal astigmatism correction at the lenticular plane. The calculation is performed using a worksheet. Because 10 degrees of misalignment would result in 35% refractive inaccuracy, it is the maximum acceptable corneal astigmatic irregularity for correction at the lenticular plane. Calculation of spherocylindrical power is specific to each toric IOL. Because the surgeon must fully understand the optical properties of the toric IOL that is going to be implanted, a comprehensive outline of a new calculation method specific to the toric BIL IOL is proposed. Primary rotational misalignment of the toric BIL IOL can be fine tuned postoperatively. Drs. Gobin and Mathysen have no financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes.

    PubMed

    Werner, Liliana; Pandey, Suresh K; Izak, Andrea M; Vargas, Luis G; Trivedi, Rupal H; Apple, David J; Mamalis, Nick

    2004-05-01

    To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.

  20. Eye growth in the second decade of life: implications for the implantation of a multifocal intraocular lens.

    PubMed

    Wilson, M Edward; Trivedi, Rupal H; Burger, Berdine M

    2009-12-01

    There is a growing interest in multifocal intraocular lens (IOL) implantation in children because they lose accommodation when a cataract is removed. Many have assumed that very little, if any, eye growth occurs in the second decade of life. Multifocal IOL implantation requires precise biometry to arrive at the correct IOL power for spectacle independence. If the eye grows and the refraction becomes myopic, spectacle dependence may return. Therefore, knowing when the eye has completed its growth is critical to the decision of when to implant a multifocal IOL. Ninety-eight eyes were analyzed retrospectively. Each had at least two axial length (AL) measurements using immersion A-scan ultrasound in the second decade of life. Globe AL was 23.36 +/- 1.52 mm at initial measurement and 23.89 +/- 1.64 mm at last measurement. Measurement data show variable growth throughout the second decade of life. Based on our data, a theoretical patient was constructed with an AL at age 10 of 23.11 mm, who would need an IOL power of 21.5 for emmetropia. That same patient would have an AL of 23.76 mm (IOL power of 19.5) at age 15 and 24.41 mm (IOL power of 17.5) at age 20. That is a 4-diopter change in the IOL power need. Axial eye growth continues throughout the second decade of life, at least to age 20. These data have important implications for the use of multifocal IOLs in the preteen and teenage years.

  1. Evaluation of loss in optical quality of multifocal intraocular lenses with glistenings.

    PubMed

    DeHoog, Edward; Doraiswamy, Anand

    2016-04-01

    To study the impact of loss in optical quality from glistenings in diffractive multifocal intraocular lenses (IOLs) using ray tracing in a model eye. Independent research laboratory, Irvine, California, USA. Experimental study. A pseudophakic eye model was constructed in Zemax, an optical ray-tracing program, using the Arizona eye model as the basis. The Mie scattering theory was used to describe the intensity and direction of light as it scattered for a spherical particle immersed in a diffractive multifocal IOL. To evaluate the impact of glistening scatter, a more advanced eye model was constructed in Fred, a nonsequential optical ray-tracing software. An evaluation of scatter and modulation transfer function (MTF) was performed for a hydrophobic biomaterial with a refractive index of 1.54 for various sizes and densities of glistenings under mesopic conditions. As predicted by the Mie theory, the amount of scatter was a function of the change in the refractive index, size of the scatterer, and volume fraction of the scatterers. This modeling showed that an increase in density of glistenings can lead to a significant drop of MTF of the IOL. This effect was more pronounced in multifocal IOLs than in monofocal IOLs. Mathematical modeling showed that glistenings in multifocal IOLs lead to a reduction in MTF of the IOL and the pseudophakic eye. The relative loss of MTF in multifocal IOLs was more significant than in monofocal IOLs because of the nature of the design. Drs. DeHoog and Doraiswamy are consultants to Advanced Vision Science, Inc. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models.

    PubMed

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-11

    In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3 mm of pupil diameter and from 0 to out-of-focus blur were collected and graphed. MTF values, measured at 555 nm of monochromatic light under each spatial frequency, were significantly higher than the values measured at 470 to 650 nm of polychromatic light. The influences of chromatic aberration on MTF values decreased with the increase in IOL diopter when the spatial frequency was ≤12 c/d, while increased effects were observed when the spatial frequency was ≥15 c/d. The MTF values of each IOL eye model were significantly lower than the MTF values of the Liou-Brennan eye models when measured at 555 nm of monochromatic light and at 470 to 650 nm of polychromatic light. The MTF values were also found to be increased with the increase in IOL diopter. With higher diopters of IOLs, the central thickness increased accordingly, which could have created increased chromatic aberration and decreased the retinal image quality. To improve the postoperative visual quality, IOLs with lower chromatic aberration should be selected for patients with short axial lengths.

  3. Stability and safety of MA50 intraocular lens placed in the sulcus

    PubMed Central

    Kemp, P S; Oetting, T A

    2015-01-01

    Purpose To describe the safety and stability of sulcus placement of the MA50 intraocular lens (IOL). Patients and methods Consecutive patients with MA50 IOLs placed in the sulcus at the University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA, from 1997 to 2012 were identified. Inclusion criteria included patients with over 4 weeks of follow-up data. AEL was compared with incidence of IOL decentration using at two-tailed Student's t-test. Results Fifty eyes of 49 patients meeting the inclusion criteria were identified. Four weeks post-operatively, the average best-corrected visual acuity was 20/30. IOL decentration occurred in 14% of patients; patients with decentered IOLs had a significantly longer average AEL (25.37 mm) than patients whose IOL remained centered (23.94 mm, P=0.017). Other complications included uveitis-glaucoma-hyphema syndrome (12%), iritis (8%), and glaucoma (6%). There were no cases of pigment dispersion syndrome or need for lens exchange. Twelve eyes (24%) had intra-operative optic capture by the anterior capsule, none of which had post-operative decentration. Conclusion The MA50 IOL is a reasonable, stable option for placement in the sulcus, with a low-risk profile; however, in eyes with longer AEL and presumably larger anterior segment, surgeons should consider placing an IOL with longer haptic distance than the MA50 to maintain centration. Optic capture of the MA50 IOL by the anterior capsule should be considered for longer eyes, as it is protective against decentration. PMID:26139047

  4. An in vitro evaluation of the Anew Zephyr open-bag IOL in the prevention of posterior capsule opacification using a human capsular bag model.

    PubMed

    Eldred, Julie A; Spalton, David J; Wormstone, I Michael

    2014-09-18

    During cataract surgery an IOL is placed within the capsular bag. Clinical studies show that IOLs with a square edge profile and complete contact between the IOL and the anterior capsule (AC) are currently the best way to prevent posterior capsule opacification (PCO). This has been challenged by recent clinical and experimental observations, which suggest that if the capsular bag is kept open with separation of contact between the AC and posterior capsule (PC) by an "open-bag device" PCO is dramatically reduced. Therefore, the current study set out to evaluate the putative merits of an open-bag IOL (Anew Zephyr) in a human capsular bag model. An in vitro organ culture model using the bag-zonular-ciliary body complex isolated from fellow human donor eyes was prepared. A capsulorhexis and lens extraction were performed, and an Alcon Acrysof IOL or Anew Zephyr IOL implanted. Preparations were secured by pinning the ciliary body to a silicone ring and maintained in 6 mL Eagle's minimum essential medium (EMEM) or EMEM supplemented with 2% vol/vol human serum (HS) and 10 ng/mL TGF-β2 for 28 days. Cell growth and capsular modifications were monitored with phase-contrast and modified dark-field microscopy. In serum-free EMEM culture conditions, cells were observed growing onto the PC of preparations implanted with an Anew Zephyr IOL, but this was retarded relative to observations in match-paired capsular bags implanted with an Alcon Acrysof IOL. In the case of cultures maintained in 2% HS-EMEM plus TGF-β2, the movement on to the PC was again delayed with the presence of an Anew Zephyr IOL. Differences in the degree of growth on the PC and matrix modifications were apparent with the different donors, but in each case the match-paired Alcon Acrysof implanted bag exhibited significantly greater coverage and modification of the capsule. The Anew Zephyr open-bag IOL performs consistently better than the Alcon Acrysof IOL in the human capsular bag model. We propose that the benefits observed with the Anew Zephyr result from a reduction in growth factor levels available within the capsular bag and a barrier function imposed by the ring haptic. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  5. Analysis of cytoskeletal proteins in posterior capsule opacification after implantation of acrylic and hydrogel intraocular lenses.

    PubMed

    Matsushima, Hiroyuki; Mukai, Kouichiro; Obara, Yoshitaka; Yoshida, Shinichiro; Clark, John I

    2004-01-01

    To analyze selected lens cytoskeletal proteins in posterior capsule opacification (PCO) 2 weeks after intraocular lens (IOL) implantation in rabbits. Department of Ophthalmology, Dokkyo University School of Medicine, Tochigi, Japan. Eight 10-week-old albino rabbits were prepared and anesthetized for phacoemulsification and aspiration of the crystalline lens and implantation of an acrylic or a hydrogel IOL. Two weeks postoperatively, the rabbits were killed and the IOLs removed for immunohistochemistry. Deparaffinized tissue sections were processed with antibodies against alpha-smooth muscle actin (alpha-SMA) and beta-crystallin to observe the types of PCO with the 2 IOL types. The proteins in the PCO tissue and the normal lens were homogenized, centrifuged, and analyzed using SDS-polyacrylamide gel electrophoresis (SDS-PAGE) densitometric analysis and Western immunoblotting for actin and vimentin. Immunohistochemistry demonstrated a fibroblastic cell type expressing alpha-SMA and partial regeneration of epithelial cells, resulting in a lenticular structure that stained irregularly for beta-crystallin. The immunoreactivity of fibroblast-like cells to beta-crystallin appeared weaker than that of the regenerated lenticular structure. SDS-PAGE showed variability in the content of cytoskeletal proteins in the insoluble fractions of the PCO. Degradation of the cytoskeletal components was greater with the acrylic IOL than with the hydrogel IOL. Cytoskeletal proteins expressed during the formation of PCO and IOL implantation may have potential as therapeutic target proteins to improve the biocompatibility of IOLs.

  6. Interaction of intraocular lenses with fibronectin and human lens epithelial cells: Effect of chemical composition and aging.

    PubMed

    Tortolano, Lionel; Serrano, Carole; Jubeli, Emile; Saunier, Johanna; Yagoubi, Najet

    2015-12-01

    The aim of this study is to investigate in vitro interactions between hydrophobic acrylate intraocular lenses (IOLs) and their biological environment. The influence of lens chemical composition and aging on fibronectin (FN) adsorption and on IOLs cytotoxicity on human lens epithelial cells was examined. Cytotoxicity of acrylate monomers used in IOLs manufacture was also investigated. Four different IOLs were included in the study: Acrysof(®), Tecnis(®), EnVista(®), and iSert(®). Implants were artificially aged in a xenon arc chamber to simulate 2 years of light exposure. Fibronectin adsorption on IOL surface was quantified using ELISA and correlated to surface roughness determined with AFM. Direct contact cytotoxicity was determined with the MTT assay and cell morphology was observed with light microscopy. Results showed that fibronectin adsorption did not differ significantly among IOLs, whatever their chemical composition. Moreover, aging conditions did not impact fibronectin adsorption. All IOLs were biocompatible even after applying 2-year aging conditions, with cell viability higher than 70%. Five acrylate monomers appeared to be toxic in the range of concentrations tested, but no monomer release from the IOLs could be detected during accelerated 2-year incubation with saline solution. This study did not reveal an influence of chemical composition and aging on protein adsorption and on biocompatibility. © 2015 Wiley Periodicals, Inc.

  7. Operating microscope light-induced phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens implantation.

    PubMed

    Kweon, Eui Yong; Ahn, Min; Lee, Dong Wook; You, In Cheon; Kim, Min Jung; Cho, Nam Chun

    2009-01-01

    The purpose of this study is to report the features of operating microscope light-induced retinal phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens (TSS PC-IOL) implantation. The charts of 118 patients who underwent TSS PC-IOL implantation surgery at Chonbuk National University Hospital (Jeonju, Korea) between March 1999 and February 2008 were retrospectively reviewed. Fourteen patients underwent combined 3-port pars plana vitrectomy and TSS PC-IOL implantation (vitrectomy group), and 104 patients underwent TSS PC-IOL implantation only (nonvitrectomy group). All surgeries were performed under the same coaxial illuminated microscope. All diagnoses were confirmed through careful fundus examination and fluorescein angiography (FA). Diagnoses of retinal phototoxic maculopathy were established in 10 (8.47%) of 118 TSS PC-IOL implantation cases. Phototoxic maculopathy occurred more frequently in the vitrectomy group than in the nonvitrectomy group (6/14 versus 4/104, respectively; P < 0.001, chi-square = 24.21). Affected patients reported decreased vision and were found to have coarse alterations of the retinal pigment epithelium (RPE). In 5 of the phototoxic maculopathy cases (50%), the visual acuity was 20/200 or worse. Operating microscope light-induced retinal phototoxic maculopathy can occur more frequently after TSS PC-IOL implantation than after casual cataract surgery, especially when TSS PC-IOL is combined with vitrectomy surgery. Surgeons should take precautions to prevent retinal phototoxicity after TSS PC-IOL implantation and vitrectomy.

  8. Reduction in mean deviation values in automated perimetry in eyes with multifocal compared to monofocal intraocular lens implants.

    PubMed

    Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F

    2014-08-01

    To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Corneal incision architecture after IOL implantation with three different injectors: an environmental scanning electron microscopy study.

    PubMed

    Mencucci, Rita; Favuzza, Eleonora; Salvatici, Maria Cristina; Spadea, Leopoldo; Allen, David

    2018-02-01

    To evaluate by Environmental Scanning Electron Microscopy (ESEM) the corneal incision architecture after intraocular lens (IOL) implantation in pig eyes, using manual, automated injectors or preloaded delivery systems. Twenty-four pig eyes underwent IOL implantation in the anterior chamber using three different injectors: manual (Monarch III) (n = 8), automated (AutoSert) (n = 8), or a preloaded system (UltraSert) (n = 8). Acrysof IQ IOLs, 21 Dioptres (D) (n = 12) and 27D (n = 12), were implanted through 2.2 mm clear corneal incisions. Incision width was measured using corneal calipers. The endothelial side of the incision was analyzed with ESEM. In each group, the final size of the corneal wound after IOL implantation, measured by calipers, was 2.3-2.4 mm. The incision architecture resulted more irregular in the Monarch group compared with the other injectors. In every group the 27D IOL-implanted specimens showed more alterations than in 21D IOL-implanted samples, and this was less evident in the UltraSert group. The Descemet tear length was higher in the Monarch group than AutoSert and UltraSert group. The automated and preloaded delivery systems provided a good corneal incision architecture; after high-power IOL implantation the incisions were more regular and less damaged with the preloaded system than with the other devices.

  10. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery: A Systematic Review and Meta-analysis.

    PubMed

    Kessel, Line; Andresen, Jens; Tendal, Britta; Erngaard, Ditte; Flesner, Per; Hjortdal, Jesper

    2016-02-01

    We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were evaluated as surgical complications and residual astigmatism. Postoperative astigmatism is an important cause of suboptimal UCDVA and need for distance spectacles. Toric IOLs may correct for preexisting corneal astigmatism at the time of surgery. We performed a systematic literature search in the Embase, PubMed, and CENTRAL databases within the Cochrane Library. We included randomized clinical trials (RCTs) if they compared toric with non-toric IOL implantation (± relaxing incision) in patients with regular corneal astigmatism and age-related cataracts. We assessed the risk of bias using the Cochrane Risk of Bias tool. We assessed the quality of evidence across studies using the GRADE profiler software (available at: www.gradeworkinggroup.org). We included 13 RCTs with 707 eyes randomized to toric IOLs and 706 eyes randomized to non-toric IOLs; 225 eyes had a relaxing incision. We found high-quality evidence that UCDVA was better in the toric IOL group (logarithm of the minimum angle of resolution [logMAR] mean difference, -0.07; 95% confidence interval [CI], -0.10 to -0.04) and provided greater spectacle independence (risk ratio [RR], 0.51; 95% CI, 0.36-0.71) and moderate quality evidence that toric IOL implantation was not associated with an increased risk of complications (RR, 1.73; 95% CI, 0.60-5.04). Residual astigmatism was lower in the toric IOL group than in the non-toric IOL plus relaxing incision group (mean difference, 0.37 diopter [D]; 95% CI, -0.55 to -0.19). We found that toric IOLs provided better UCDVA, greater spectacle independence, and lower amounts of residual astigmatism than non-toric IOLs even when relaxing incisions were used. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. The impact on vision of aspheric to spherical monofocal intraocular lenses in cataract surgery: a systematic review with meta-analysis.

    PubMed

    Schuster, Alexander K; Tesarz, Jonas; Vossmerbaeumer, Urs

    2013-11-01

    To provide a summary of the impact on vision of an aspheric intraocular lens (IOL) compared with a spherical IOL in cataract surgery. Systematic review with meta-analysis. Patients from published randomized controlled trials (RCTs) of cataract surgery with aspheric compared with spherical monofocal IOL implantation. We systematically searched the peer-reviewed literature in MEDLINE, EMBASE, Web of Science, BIOSIS, and the Cochrane Library according to the Cochrane Collaboration method to identify relevant RCTs. The inclusion criteria were RCTs on cataract surgery comparing the use of aspheric versus spherical IOL implantation that assessed visual acuity, contrast sensitivity, or quality of vision. The effects were calculated as mean differences or standardized mean differences (Hedges' g) and pooled using random-effect models. Best-corrected visual acuity (BCVA), contrast sensitivity, and subjective perception of the quality of vision. Forty-three studies provided data and were included, comprising 2076 eyes implanted with aspheric IOLs and 2034 eyes implanted with spherical IOLs. The BCVA showed a significant difference for aspheric IOLs (-0.01 logarithm of the minimum angle of resolution; 95% confidence interval [CI], -0.02 to -0.00). For contrast sensitivity, a significant advantage for aspheric IOLs was found under photopic and mesopic light conditions (photopic: Hedges' g 0.42, 95% CI 0.24-0.61 (3 cycles per degree [cpd]) to 0.53, 95% CI 0.33-0.73 (12 cpd); mesopic: Hedges' g 0.49, 95% CI 0.23-0.75 (1.5 cpd) to 0.76, 95% CI 0.52-1.00 (18 cpd)). Questionnaires targeting the subjective perception of quality of vision yielded less conclusive results. Overall, a patient may achieve better contrast sensitivity with an aspheric IOL than with a spherical IOL, especially under dim light. There was no clinically relevant difference in BCVA between aspheric and spherical IOL implantation. The findings on the subjective perception of visual quality were heterogeneous with no clear result favoring either option. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. Management of bipseudophakia with implantation of an iris claw lens.

    PubMed

    Izak, Milan G J; Werner, Liliana; Izak, Andrea M; Apple, David J

    2003-07-01

    We discuss a case of bipseudophakia with secondary dislocation of a posterior chamber intraocular lens (IOL) into the anterior chamber that was managed by explantation of the anterior and posterior chamber IOLs and implantation of an iris claw IOL.

  13. Design of a Test Bench for Intraocular Lens Optical Characterization

    NASA Astrophysics Data System (ADS)

    Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its analysis through expansion in Zernike polynomials.

  14. Moxifloxacin superior to cefuroxime in reducing bacterial adhesion of Staphylococcus epidermidis on hydrophobic intraocular lenses.

    PubMed

    Benbouzid, Fathalah; Kodjikian, Laurent; Hartmann, Daniel; Renaud, François; Baillif, Stéphanie

    2016-02-01

    To compare the anti-adhesive effect of cefuroxime and moxifloxacin on the primary attachment phase of Staphylococcus epidermidis on hydrophobic acrylic intraocular lenses (IOLs). Forty hydrophobic acrylic IOLs were used. Two groups of IOLs were soaked in a moxifloxacin (Mox-T1: 0.5 mg/0.1 ml) or a cefuroxime (Cef-T1: cefuroxime 1 mg/0.1 ml) solution before incubation in a S. epidermidis bacterial suspension. Two other groups were incubated in the bacterial suspension before antibiotics (Cef-T2 and Mox-T2) were added. The control group (Ctrl) consisted of IOLs incubated in the bacterial suspension. After incubation, IOLs were sonicated and vortexed. The resultant suspension was spread over a nutritive agar plate. Bacterial colonies were counted after 24 hr of incubation. Mean number of colony-forming units per IOL was Cef-T1: 184 × 10(3) (SE: 5.24; SD: 28.21), Cef-T2: 117 × 10(3) (SE: 5.74; SD: 30.37), Mox-T1: 1.27 × 10(3) (SE: 0.12; SD: 0.61), Mox-T2: 25 × 10(3) (SE:1.98; SD: 9.72) and Ctrl: 361 × 10(3) (SE: 26.9; SD: 107.6). The number of adhering bacteria did not vary whether cefuroxime was added before or after IOL incubation in the bacterial suspension (p = 0.132). Moxifloxacin was more effective in reducing the number of adhering bacteria when used before IOL incubation (p < 0.001). Overall for T1 and T2, moxifloxacin was more effective than cefuroxime in reducing bacterial adhesion on IOLs (p < 0.001). Moxifloxacin and cefuroxime significantly reduced S. epidermidis adhesion on hydrophobic acrylic IOLs. The anti-adhesive effect was superior with moxifloxacin. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  15. Bilateral implantation of +3.0 D multifocal toric intraocular lenses: results of a US Food and Drug Administration clinical trial.

    PubMed

    Lehmann, Robert; Modi, Satish; Fisher, Bret; Michna, Magda; Snyder, Michael

    2017-01-01

    The purpose of this study was to evaluate the clinical outcomes of apodized diffractive +3.0 D multifocal toric intraocular lens (IOL) implantations in subjects with preoperative corneal astigmatism. This was a prospective cohort study conducted at 21 US sites. The study population consisted of 574 subjects, aged ≥21 years, with preoperative astigmatism 0.75-2.82 D, and potential postoperative visual acuity (VA) ≥0.2 logMAR, undergoing bilateral cataract removal by phacoemulsification. The intervention was bilateral implantation of aspheric apodized diffractive +3.0 D multifocal toric or spherical multifocal nontoric IOLs. The main outcome measures were monocular uncorrected near and distance VA and safety at 12 months. A total of 373/386 and 182/188 subjects implanted with multifocal toric and nontoric IOLs, respectively, completed 12-month follow-up after the second implantation. Toric IOLs were nonin-ferior in monocular uncorrected distance (4 m) and near (40 cm) VA but had >1 line better binocular uncorrected intermediate VA (50, 60, and 70 cm) than nontoric IOLs. Toric IOLs reduced cylinder to within 0.50 D and 1.0 D of target in 278 (74.5%) and 351 (94.1%) subjects, respectively. Mean ± standard deviation (SD) differences between intended and achieved axis orientation in the first and second implanted eyes were 5.0°±6.1° and 4.7°±4.0°, respectively. Mean ± SD 12-month IOL rotations in the first and second implanted eyes were 2.7°±5.8° and 2.2°±2.7°, respectively. No subject receiving toric IOLs required secondary surgical intervention due to optical lens properties. Multifocal toric IOLs were noninferior to multifocal nontoric IOLs in uncorrected distance and near VAs in subjects with preexisting corneal astigmatism and effectively corrected astigmatism of 0.75-2.82 D.

  16. The South Asian cataract management study: complications, vision outcomes, and corneal endothelial cell loss in a randomized multicenter clinical trial comparing intracapsular cataract extraction with and without anterior chamber intraocular lens implantation.

    PubMed

    Snellingen, T; Shrestha, J K; Huq, F; Husain, R; Koirala, S; Rao, G N; Pokhrel, R P; Kolstad, A; Upadhyay, M P; Apple, D J; Arnesen, E; Cheng, H; Olsen, E G; Vogel, M

    2000-02-01

    To determine clinical outcomes of primary intracapsular cataract surgery with and without implantation of anterior chamber lenses. A multicenter randomized clinical trial. One thousand two hundred twenty-nine male and female patients 40-75 years of age with senile cataract. Study patients were recruited from screening eye camps and outpatient clinics. Randomization to the two treatment groups was performed after screening for predetermined inclusion and exclusion criteria. Demographics, visual acuity, intraocular pressures, and corneal endothelial cell data were recorded before surgery and at 6 weeks, 12 months, and 24 months after surgery. Monitoring of the study was secured by a standardized image documentation procedure on all patients using the IMAGEnet digital imaging system. Analysis of corneal endothelial cell images was performed with the Cell Soft software (Topcon Corporation, Japan). Visual acuity and central corneal endothelial cell loss. The patients were randomized to intraocular lens (IOL; n = 616) and no IOL (n = 613) implantation. Surgical complications were reported in 177 (14.4%) patients (IOL = 14.8%; no IOL = 14.0%). The most frequent complication observed was vitreous loss which occurred in 10.3% of eyes (IOL = 11.2%; no IOL = 9.5%). At the final examination (2 years after surgery), 88% of the operated eyes had a best corrected vision of 6/18 or better (IOL = 88.8%; no IOL = 86.6%). Analysis of corneal endothelial cell data showed a small but significantly greater cell loss 6 weeks after surgery in eyes with IOL compared with those without IOL, but no overall difference was found between the treatment groups in the long term follow-up. The findings indicate that there is a rationale for the use of anterior chamber intraocular lenses in primary intracapsular cataract surgery.

  17. Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses

    PubMed Central

    Lyu, J; Zhao, P-q

    2016-01-01

    Purpose We report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support. Materials and methods The technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels. Results The patients were followed for 5–14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications. Conclusion The simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs. PMID:26795420

  18. Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses.

    PubMed

    Lyu, J; Zhao, P-Q

    2016-05-01

    PurposeWe report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support.Materials and methodsThe technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels.ResultsThe patients were followed for 5-14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications.ConclusionThe simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs.

  19. Prevention of increased abnormal fundus autofluorescence with blue light-filtering intraocular lenses.

    PubMed

    Nagai, Hiroyuki; Hirano, Yoshio; Yasukawa, Tsutomu; Morita, Hiroshi; Nozaki, Miho; Wolf-Schnurrbusch, Ute; Wolf, Sebastian; Ogura, Yuichiro

    2015-09-01

    To observe changes in fundus autofluorescence 2 years after implantation of blue light-filtering (yellow-tinted) and ultraviolet light-filtering (colorless) intraocular lenses (IOLs). Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan, and the Department of Ophthalmology, University of Bern, Bern, Switzerland. Prospective comparative observational study. Patients were enrolled who had cataract surgery with implantation of a yellow-tinted or colorless IOL and for whom images were obtained on which the fundus autofluorescence was measurable using the Heidelberg Retina Angiogram 2 postoperatively. The fundus autofluorescence in the images was classified into 8 abnormal patterns based on the classification of the International Fundus Autofluorescence Classification Group, The presence of normal fundus autofluorescence, geographic atrophy, and wet age-related macular degeneration (AMD) also was recorded. The fundus findings at baseline and 2 years postoperatively were compared. Fifty-two eyes with a yellow-tinted IOL and 79 eyes with a colorless IOL were included. Abnormal fundus autofluorescence did not develop or increase in the yellow-tinted IOL group; however, progressive abnormal fundus autofluorescence developed or increased in 12 eyes (15.2%) in the colorless IOL group (P = .0016). New drusen, geographic atrophy, and choroidal neovascularization were observed mainly in the colorless IOL group. The incidence of AMD was statistically significantly higher in the colorless IOL group (P = .042). Two years after cataract surgery, significant differences were seen in the progression of abnormal fundus autofluorescence between the 2 groups. The incidence of AMD was lower in eyes with a yellow-tinted IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Combined Special Capsular Tension Ring and Toric IOL Implantation for Management of Astigmatism and High Axial Myopia with Cataracts.

    PubMed

    Zhao, Yang; Li, Jiaxin; Yang, Ke; Li, Xiao; Zhu, Siquan

    2018-01-01

    This study aimed to compare the effects of toric intraocular lens (IOL) implantation with a capsular tension ring and toric IOL implantation only in patients with axial myopic astigmatism who had undergone cataract surgery. Of 34 patients with axial myopia, 16 patients who had received IOL and capsular tension ring (CTR) implantation were included in the combined group and 18 patients who received toric IOL implantation only were included in the simple group. Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA) were evaluated by measuring subjective refraction, residual astigmatism, and the toric IOL axis six months post-surgery. At six months postoperatively, the UCVA for the combined and simple groups was 4.6 ± 0.1 and 4.5 ± 0.2, respectively, a statistically significant difference (t = 3.531, P<0.05). The toric IOL in all of the cases was located in the capsular sac, but there were more cases with IOL rotation (12 eyes) in the simple group than in the combined group (4 eyes). The rotation angles were 20°~30° (one eye), 10°~20° (four eyes), and <10° (seven eyes) compared with 2°~5° (four eyes). The residual astigmatism was -0.50 ± 0.25 D in the combined group, not a significant difference from the predicted residual astigmatism (-0.35 ± 0.13 D). There was a significant difference in the simple group (-1.25 ± 0.33 D) when the predicted residual astigmatism was compared (-0.37 ± 0.11 D) (t = -9.511, P < 0.01). In patients with axial myopic astigmatism, CTR can effectively increase the rotational stability of a toric IOL, achieving improvement in corneal astigmatism and visual acuity.

  1. Intrapartum intervention rates and perinatal outcomes following induction of labour compared to expectant management at term from an Australian perinatal centre.

    PubMed

    Zhao, Yi; Flatley, Christopher; Kumar, Sailesh

    2017-02-01

    Induction of labor (IOL) is a common obstetric intervention, yet its impact on intervention rates and perinatal outcomes is conflicting. To evaluate the impact of IOL on intrapartum intervention rates and perinatal outcomes in women with singleton pregnancies at term. This was a retrospective, cross-sectional study of term singleton deliveries at the Mater Mother's Hospital in Brisbane, Australia in 2007-2013. The IOL cohort was compared to an expectantly managed group. Of the final cohort (44 698 women), 64.4% had expectant management and 35.6% had IOL. Multivariate analyses showed that IOL was associated with lower odds of spontaneous vaginal delivery from ≥37 weeks gestation. The risk of emergency caesarean for non-reassuring fetal status was also higher in the IOL cohort at 40 and 41 weeks gestation. For women who were managed expectantly, the highest rate of spontaneous vaginal delivery and the lowest rate of emergency caesareans occurred at 39 weeks gestation. For women who underwent IOL, the nadir emergency caesarean rate and the highest spontaneous vaginal delivery rate was also at 39 weeks. Rates of neonatal intensive car unit admission were higher in the IOL group at 37 weeks (adjusted odds ratio (aOR) 3.11, 95% CI: 2.62-3.68) and 38 weeks (aOR 1.78, 95% CI: 1.55-2.04) and lower at >42 weeks (OR 0.35, 95% CI: 0.14-0.81) respectively. IOL compared to expectant management is associated with lower spontaneous vaginal delivery rates and increased risk of emergency caesarean for intrapartum fetal compromise with broadly comparable perinatal outcomes. © 2017 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  2. Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study.

    PubMed

    Gutowski, Christina J; Darvish, Kurosh; Ilyas, Asif M; Jones, Christopher M

    2017-02-01

    The interosseous ligament (IOL) is known to be an important longitudinal stabilizer of the forearm. We hypothesize that it may also contribute to transverse stability, with pronosupination tensioning of the radius relative to the ulna. Therefore, when injured, we predict the interosseous space should widen in the transverse plane, enough to be appreciable on plain radiographs. A measurable difference in interosseous space, comparing an injured with an uninjured forearm, can potentially be of diagnostic and clinical value. Ten fresh-frozen cadaver arms (from 5 individuals) were radiographed in 6 different positions of forearm supination, first in an uninjured state and then with the IOL sectioned, both partially (central band only) and completely. The transverse interosseous distance was measured on radiographs using edge detection software and compared using analysis of variance and contrast analysis. The maximum range of pronosupination was also compared before and after injury, using a paired t test. Average maximum supination increased from 84° to 106°, and pronation from 69° to 84°, after the IOL was sectioned completely. Sectioning of the IOL led to a statistically significant increase in the interosseous distance, a minimum of 2 mm, in all but one forearm position. The IOL of the forearm plays an important role in providing transverse stability to the radius and ulna. When the IOL is sectioned, the forearm exhibits increased pronosupination range of motion. Radiographs of bilateral forearms taken in identical rotational position can reliably differentiate between an intact and torn IOL in cadavers. The IOL's stabilizing role during forearm rotation suggests a novel strategy for diagnosing forearm IOL injury using comparative radiographic measurements. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Secondary membrane formation after cataract surgery with primary intraocular lens implantation in children.

    PubMed

    Bar-Sela, Shai M; Har-Noy, Nurit Birman; Spierer, Abraham

    2014-08-01

    To evaluate the risk factors for secondary membrane (SM) formation after congenital cataract surgery with intraocular lens (IOL) implantation. A retrospective non-interventional comparative study. Thirty-nine patients (63 eyes) aged 1-135 months. The study included patients who underwent cataract extraction and primary IOL implantation between 1994 and 2001 at the University Hospital. The postoperative follow-up was 6-24 months. Thirty-three eyes received a poly(methyl methacrylate) (PMMA) IOL without square edges, 29 eyes received a hydrophobic acrylic IOL with truncated square edges (AcrySof), and there was no data for IOL type in one eye. Thirty-nine eyes had primary posterior capsulotomy (PPC) and anterior vitrectomy (AV) and in 24 eyes the posterior capsule was left intact. Cox proportional hazard regression analysis was performed to identify significant risk factors for SM formation, and Wilcoxon test to evaluate the difference in time from surgery to SM formation. SM developed in 24 eyes (38 %)--58 % of eyes with an intact posterior capsule and 26 % of eyes having PPC and AV, 42 % of eyes with a PMMA IOL, and 34 % of eyes with an AcrySof lens. In multivariate Cox regression analysis intraoperative PPC and AV (P = 0.02) and AcrySof lens implantation (P = 0.097) were associated with decreased postoperative incidence of SM formation. Median time until SM development was 2.9 months with PMMA IOLs (range 1-17 months) and 6 months with AcrySof lenses (range 1-21.8 months) (P = 0.037). Posterior capsule management as well as IOL design and material influence the incidence and the timing of SM formation after primary IOL implantation in children.

  4. Pigment dispersion syndrome and pigmentary glaucoma after secondary sulcus transscleral fixation of single-piece foldable posterior chamber intraocular lenses in Chinese aphakic patients.

    PubMed

    Tong, Nianting; Liu, Fuling; Zhang, Ting; Wang, Liangyu; Zhou, Zhanyu; Gong, Huimin; Yuan, Fuxiang

    2017-05-01

    To describe secondary pigment dispersion syndrome (PDS) and pigmentary glaucoma after secondary sulcus transscleral fixation of 1-piece hydrophobic acrylic foldable posterior chamber intraocular lenses (PC IOLs) in aphakic patients in a Chinese population. Department of Ophthalmology, Qingdao Municipal Hospital, Qingdao, China. Retrospective case series. This chart review included eyes that had secondary sulcus transscleral fixation of a 1-piece hydrophobic acrylic foldable PC IOL (Tecnis ZCB00) between March 2011 and March 2014. The patients' demographic data, clinical data, postoperative complications, intervals between initial surgery and the onset of PDS, pigmentary glaucoma occurrences, and findings on slitlamp biomicroscopy, gonioscopy, and ultrasound biomicroscopy (UBM) were recorded. The study comprised 23 consecutive eyes of 21 patients. Seventeen eyes of 16 patients were diagnosed with PDS, and 7 eyes of 6 patients were diagnosed with pigmentary glaucoma. The slitlamp examination and UBM showed that the location between the IOL optic and the posterior surface of the iris was very close. Slitlamp examination of the anterior chamber angle using a gonioscope showed dense pigment deposition on the IOL surfaces. A reverse pupillary block was found in 10 eyes of 9 patients. Other postoperative complications included intraocular hemorrhage, pupillary capture of the IOL optic, IOL tilt, IOL decentration, IOL dislocation, and suture erosion. The 1-piece hydrophobic acrylic foldable PC IOL was not suitable for sulcus transscleral fixation because of a high incidence of PDS and pigmentary glaucoma after surgery in a Chinese population. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Methods of classification for women undergoing induction of labour: a systematic review and novel classification system.

    PubMed

    Nippita, T A; Khambalia, A Z; Seeho, S K; Trevena, J A; Patterson, J A; Ford, J B; Morris, J M; Roberts, C L

    2015-09-01

    A lack of reproducible methods for classifying women having an induction of labour (IOL) has led to controversies regarding IOL and related maternal and perinatal health outcomes. To evaluate articles that classify IOL and to develop a novel IOL classification system. Electronic searches using CINAHL, EMBASE, WEB of KNOWLEDGE, and reference lists. Two reviewers independently assessed studies that classified women having an IOL. For the systematic review, data were extracted on study characteristics, quality, and results. Pre-specified criteria were used for evaluation. A multidisciplinary collaboration developed a new classification system using a clinically logical model and stakeholder feedback, demonstrating applicability in a population cohort of 909 702 maternities in New South Wales, Australia, over the period 2002-2011. All seven studies included in the systematic review categorised women according to the presence or absence of varying medical indications for IOL. Evaluation identified uncertainties or deficiencies across all studies, related to the criteria of total inclusivity, reproducibility, clinical utility, implementability, and data availability. A classification system of ten groups was developed based on parity, previous caesarean, gestational age, number, and presentation of the fetus. Nulliparous and parous women at full term were the largest groups (21.2 and 24.5%, respectively), and accounted for the highest proportion of all IOL (20.7 and 21.5%, respectively). Current methods of classifying women undertaking IOL based on medical indications are inadequate. We propose a classification system that has the attributes of simplicity and clarity, uses information that is readily and reliably collected, and enables the standard characterisation of populations of women having an IOL across and within jurisdictions. © 2015 Royal College of Obstetricians and Gynaecologists.

  6. Comparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses

    PubMed Central

    Yamauchi, Tomofusa; Tabuchi, Hitoshi; Takase, Kosuke; Ohsugi, Hideharu; Ohara, Zaigen; Kiuchi, Yoshiaki

    2013-01-01

    Purpose To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. Methods The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patients who were implanted with Tecnis® multifocal IOLs bilaterally. The monofocal group was an age- and sex-matched control group, and included 85 patients who were implanted with Tecnis® monofocal IOLs bilaterally. Lens opacity grading, the radius of corneal curvature, corneal astigmatism, axial length and the refractive status were measured preoperatively. Pupil size, ocular aberrometry, distance, intermediate and near visual acuity, contrast sensitivity with and without glare and the responses to a quality-of-vision questionnaire were evaluated pre- and postoperatively. Results The uncorrected near visual acuity was significantly better in the multifocal group, whereas both the corrected intermediate and near visual acuity were better in the monofocal group. Contrast sensitivity (with and without glare) was significantly better in the monofocal group. The rate of spectacle dependency was significantly lower in the multifocal group. There were no significant differences between the two groups regarding most items of the postoperative quality-of-vision questionnaire (VFQ-25), with the exception that the patients in the monofocal group reported fewer problems with nighttime driving. Conclusions The multifocal IOLs used in this study reduced spectacle dependency more so than monofocal IOLs and did not compromise the subjective visual function, with the exception of nighttime driving. PMID:23840836

  7. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    PubMed

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p < 0.0001). Major complications included a marked elevation in intraocular pressure (7.8 %), pupillary capture (6.5 %), and vitreous hemorrhage (2.6 %). Based on the classification system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  8. Temporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.

    PubMed

    Hwang, Sungsoon; Lim, Dong Hui; Lee, Soomin; Choi, Daye Diana; Chung, Eui-Sang; Chung, Tae-Young

    2018-04-01

    To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL implantation within the first 3 years of life from 1999 to 2013 at Samsung Medical Center were reviewed. Twenty-eight eyes from 18 patients underwent single IOL implantation (monopseudophakia group), and 32 eyes of 20 patients underwent temporary piggyback IOL implantation in congenital cataract surgery (polypseudophakia group). The mean age at initial cataract surgery was 15.8 months in the monopseudophakia group and 11.1 months in the polypseudophakia group (P = 0.144). The average follow-up duration was 133 months in the monopseudophakia group and 120 months in the polypseudophakia group (P = 0.391). The best-corrected visual acuity at the last visit was 0.36 logMAR in the monopseudophakia group and 0.55 logMAR in the polypseudophakia group (P = 0.044). Four (14%) and 14 (44%) reoperations for complications within the anterior segment were performed in the monopseudophakia group and polypseudophakia group, respectively (P = 0.042). Four cases (14.3%) in the monopseudophakia group and 13 cases (40.6%) in the polypseudophakia group had a glaucoma-related adverse event (P = 0.086). Compared with primary single IOL implantation in congenital cataract, temporary piggyback IOL implantation produced worse visual acuity, higher reoperation rate, and higher risk of secondary glaucoma. Temporary piggyback IOL implantation does not have benefit in congenital cataract.

  9. Further improvement of an intraocular lens holder for more physiological measurements within a mechanical eye model

    NASA Astrophysics Data System (ADS)

    Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas

    2017-04-01

    To evaluate the performance of intraocular lenses to treat cataract, an optomechanical eye model was developed. One of the most crucial components is the IOL holder, which should guarantee a physiological representation of the capsular bag and a stable position during measurement sequences. Individual holders are required due to the fact that every IOL has different geometric parameters. A method which allows obtaining the correct dimensions for the holder of a special IOL was developed and tested, by verifying the position of the IOL before and after a measurement sequence. Results of telecentric measurements and MTF measurements show that the IOL position does not change during the displacement sequence induced by the stepper motors of the eye model.

  10. Ocular wavefront analysis of aspheric compared with spherical monofocal intraocular lenses in cataract surgery: Systematic review with metaanalysis.

    PubMed

    Schuster, Alexander K; Tesarz, Jonas; Vossmerbaeumer, Urs

    2015-05-01

    This review was conducted to compare the physical effect of aspheric IOL implantation on wavefront properties with that of spherical IOL implantation. The peer-reviewed literature was systematically searched in Medline, Embase, Web of Science, Biosis, and the Cochrane Library according to the Cochrane Collaboration method. Inclusion criteria were randomized controlled trials comparing the use of aspheric versus spherical monofocal IOL implantation that assessed visual acuity, contrast sensitivity, or quality of vision. A secondary outcome was ocular wavefront analysis; spherical aberration, higher-order aberrations (HOAs), coma, and trefoil were evaluated. Effects were calculated as standardized mean differences (Hedges g) and were pooled using random-effect models. Thirty-four of 43 studies provided data for wavefront analysis. Aspheric monofocal IOL implantation resulted in less ocular spherical aberration and fewer ocular HOAs than spherical IOLs. This might explain the better contrast sensitivity in patients with aspheric IOLs. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Intraocular Lens Opacification After Endothelial Keratoplasty as Analyzed by Environmental Scanning Electron Microscopy.

    PubMed

    Verdaguer, Paula; Gris, Oscar; Casaroli-Marano, Ricardo P; Elies, Daniel; Muñoz-Gutierrez, Gerardo; Güell, Jose L

    2015-08-01

    To describe a case of hydrophilic intraocular lens (IOL) opacification based on IOL analysis after Descemet stripping automated endothelial keratoplasty. A 60-year-old woman had uneventful phacoemulsification after the implantation of a hydrophilic IOL (Akreos-Adapt; Bausch & Lomb) into both eyes. Because of postoperative corneal decompensation in the right eye, 2 Descemet stripping automated endothelial keratoplasty operations were performed within 1 year. After the second procedure, the graft was not well attached, requiring an intracameral injection of air on day 3. After 1 year, opacification was observed on the superior 2/3 of the anterior surface of the IOL, along with a significant decrease in visual acuity. The IOL was explanted 6 months after the opacification. Environmental scanning electron microscopy followed by x-ray microanalysis revealed an organic biofilm on the surface of the IOL. To our knowledge, this is the first reported case in which the material deposited on the lens is organic rather than calcific.

  12. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    PubMed Central

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  13. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    PubMed

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  14. Morphologic compatibility or intraocular lens haptics and the lens capsule.

    PubMed

    Nagamoto, T; Eguchi, G

    1997-10-01

    To evaluate the mechanical relationship between the intraocular lens (IOL) haptic and the capsular bag by quantitatively analyzing the fit of the haptic with the capsule equator and the capsular bag deformity induced by the implanted lens haptics. Division of Morphogenesis, Department of Developmental Biology, National Institute for Basic Biology, Okazaki, Japan. Following implantation of a poly(methyl methacrylate)(PMMA) ring in three excised human capsular bags with continuous curvilinear capsulorhexis (CCC), IOLs with different overall lengths or haptic designs were implanted in the bags and photographed. The straight length of the area of contact between the haptic and the capsule equator on the photographs was measured to provide a quantitative index of in-the-bag fixation and the length from the external margin of the PMMA ring to the external margin of the loop along the maximal diameter of the capsular bag, to indicate the quantitative degree of capsular deformity induced by an IOL. An IOL with modified-C loops produced better fit along the capsule equator and less deformity than an IOL with modified-J loops, and an IOL with an overall length of 12.0 or 12.5 mm produced a sufficiently good fit and less distortion of the capsular bag than an IOL with an overall length over 13.0 mm. An IOL with modified-C loops and an overall length of 12.0 or 12.5 mm is adequate for in-the-bag implantation following CCC.

  15. Effects of blue light-filtering intraocular lenses on the macula, contrast sensitivity, and color vision after a long-term follow-up.

    PubMed

    Kara-Junior, Newton; Espindola, Rodrigo F; Gomes, Beatriz A F; Ventura, Bruna; Smadja, David; Santhiago, Marcony R

    2011-12-01

    To evaluate the possible side effects and potential protection 5 years after implantation of an intraocular lens (IOL) with a blue-light filter (yellow tinted). Ophthalmology Department, University of São Paulo, São Paulo, Brazil. Prospective randomized clinical study. Patients with bilateral visually significant cataract randomly received an ultraviolet (UV) and blue light-filtering IOL (Acrysof Natural SN60AT) in 1 eye and an acrylic UV light-filtering only IOL (Acrysof SA60AT) in the fellow eye. The primary outcome measures were contrast sensitivity, color vision, and macular findings 5 years after surgery. The study enrolled 60 eyes of 30 patients. There were no significant clinical or optical coherence tomography findings in terms of age-related macular degeneration in any eye. There were no statistically significant differences in central macular thickness between the 2 IOL groups (P=.712). There were also no significant between-group differences under photopic or scotopic conditions at any spatial frequency studied. No statistically significant differences in the color discrimination test were found between the 2 IOL groups (P=.674). After 5 years, there were no significant differences in color perception, scotopic contrast sensitivity, or photopic contrast sensitivity between the blue light-filtering (yellow-tinted) IOL and the IOL with a UV-light filter only (untinted). The potential advantage of the tinted IOL in providing protection to macular cells remains unclear. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses.

    PubMed

    Kleinmann, Guy; Apple, David J

    2007-08-01

    To evaluate the R-INJ-04 soft-tipped injector, a new injector with an integral round nozzle manufactured by Rayner Intraocular Lenses, England. 16 Rayner C-flex intraocular lenses (IOLs; Rayner Intraocular lenses, England) ranging between +10 and +30 D (2 for each power) were tested. An ophthalmic viscoelastic device (Healon, AMO, Santa Ana, California, USA) was applied to the injectors. The IOLs were loaded according to the company injector's instructions for use and were injected into a Petri dish. After the injection, all the IOLs and nozzles were evaluated by gross (macroscopic) and microscopic analyses and photographed under a light microscope. One lens of each power and the cartridge used for the implantation were then sent for further analysis by scanning electron microscopy (SEM). The rest of the IOLs were tested for power and modulation transfer function (MTF). All the injections were successful. No damage to the IOLs or to the injectors was found by gross examination, light microscopy and SEM. No deposits were found on the IOL optical surfaces or haptics. Power and MTF analysis showed a close match with the original measurements. Our results suggest that the R-INJ-04 soft-tipped injector is safe for the implantation of the C-flex IOL with power range from 10 to 30 D. No structural damage to the IOLs or to the injectors was found, and the lens power and light transmission properties were not damaged in any way by the injection process.

  17. Visual outcome and rotational stability of open loop toric intraocular lens implantation in Indian eyes.

    PubMed

    Venkataraman, Arvind

    2013-11-01

    To assess the visual outcome and rotational stability of single-piece open loop toric Intra Ocular Lens (IOL) in a clinical setting. In a prospective study, 122 eyes of 77 patients were followed up for a period of 12 months after cataract surgery with toric open loop IOL implantation. The pre-operative markings for the position of incision and IOL placement were done under slit lamp by anterior stromal puncture. The visual acuity, refraction, and IOL position were assessed at day 1, 1 week, 1 month, 3 months, 6 months, and 12 months after surgery. The mean age of the cohort was 56 yrs (S.D. 13.88; range 16 to 87 years). The mean pre-operative cylinder of corneal astigmatism was 1.37 D. (SD 0.79, range 1.0 to 5.87 D). Mean post-operative refractive cylinder was 0.36 D (SD 0.57, range 0 to 1.50 D) at 12 months. Ninety-seven percent of the eyes were within 1 D of residual astigmatism. Ninety-four percent of patients had uncorrected visual acuity of 20/30 or better. Four eyes required IOL repositioning due to rotation. At 12 months, 96.7% of the IOLs were within 10 degrees of the target axis. There was no rotation seen after 6 months. Toric IOLs are very effective and consistent in correcting astigmatism during the cataract surgery. IOL rotation happens mostly within a month of surgery, and if significant, requires early repositioning.

  18. Light-adjustable lens.

    PubMed Central

    Schwartz, Daniel M

    2003-01-01

    PURPOSE: First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS: After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cytotoxicity, leaching, precision of adjustment, optical quality after adjustment, and mechanical properties. Light-adjustable IOLs were then tested in vivo for biocompatibility and precision of adjustment in a rabbit model. In collaboration with Zeiss-Meditec, a digital LDD was developed and tested to correct for higher-order aberrations in light-adjustable IOLs. RESULTS: The results establish that a biocompatible silicone IOL can be fabricated and adjusted using safe levels of light. There was no evidence of cytotoxicity or leaching. Testing of mechanical properties revealed no significant differences from commercial controls. Implantation of light-adjustable lenses in rabbits demonstrated- excellent biocompatibility after 6 months, comparable to a commercially available IOL. In vivo spherical (hyperopic and myopic) adjustment in rabbits was achieved using an analog light delivery system. The digital light delivery system was tested and achieved correction of higher-order aberrations. CONCLUSION: A silicone light-adjustable IOL and LDD have been developed to enable postoperative, noninvasive adjustment of lens power. The ability to correct higher-order aberrations in these materials has broad potential applicability for optimization of vision in patients undergoing cataract and refractive surgery. PMID:14971588

  19. Spin-ice behavior of three-dimensional inverse opal-like magnetic structures: Micromagnetic simulations

    NASA Astrophysics Data System (ADS)

    Dubitskiy, I. S.; Syromyatnikov, A. V.; Grigoryeva, N. A.; Mistonov, A. A.; Sapoletova, N. A.; Grigoriev, S. V.

    2017-11-01

    We perform micromagnetic simulations of the magnetization distribution in inverse opal-like structures (IOLS) made from ferromagnetic materials (nickel and cobalt). It is shown that the unit cell of these complex structures, whose characteristic length is approximately 700 nm, can be divided into a set of structural elements some of which behave like Ising-like objects. A spin-ice behavior of IOLS is observed in a broad range of external magnetic fields. Numerical results describe successfully the experimental hysteresis curves of the magnetization in Ni- and Co-based IOLS. We conclude that ferromagnetic IOLS can be considered as the first realization of three-dimensional artificial spin ice. The problem is discussed of optimal geometrical properties and material characteristics of IOLS for the spin-ice rule fulfillment.

  20. Polymethyl methacrylate intraocular lens opacification 20 years after cataract surgery: A case report in a tertiary eye hospital in Saudi Arabia

    PubMed Central

    Al-Otaibi, Abdullah G.; Al-Qahtani, Elham S.

    2011-01-01

    Snowflake degeneration is a slow progressive opacification of polymethyl methacrylate (PMMA) intraocular lenses (IOLs). This late postoperative complication can occur a decade or later after implantation. The deposits are composed of IOL materials that tend to aggregate centrally. There is a relative paucity of the literature on snowflake degeneration of IOLs. Symptoms can range from mild visual disturbance to significant loss of visual acuity. In cases of opacification after IOL implantation, the different diagnosis should include snowflake degeneration to prevent surgical intervention such as lens exchange or explantation unless clinically warranted. We report a case of late optical opacification of a PMMA IOL, the clinical diagnosis and treatment that increased best corrected vision. PMID:23960977

  1. Surface cytologic features on intraocular lenses: can increased biocompatibility have disadvantages?

    PubMed

    Hollick, E J; Spalton, D J; Ursell, P G

    1999-07-01

    To compare the anterior surface cytologic features and effect on blood-aqueous barrier of polymethyl methacrylate, silicone, and hydrogel intraocular lens (IOL) implants to give an indication of their biocompatibility. This prospective study was performed at an English-teaching hospital. Ninety eyes were randomized to receive a polymethyl methacrylate, silicone, or hydrogel implant. A standardized surgical protocol was performed by a single surgeon using phacoemulsification. Patients were seen at intervals for 1 year. Measurements of visual acuity, contrast sensitivity, and anterior chamber laser flare and cells were obtained; and an assessment of lens cytologic features using specular microscopy of the anterior IOL surface was performed. Visual acuity and contrast sensitivity were not significantly different among the 3 groups. Hydrogel IOLs were associated with fewer inflammatory cells on their surface than polymethyl methacrylate and silicone IOLs (P<.001), but with significantly more lens epithelial cells (LECs) (P<.001). Patients with hydrogel implants without LECs had greater blood-aqueous barrier breakdown than those with LECs. The hydrogel IOLs were associated with a reduced inflammatory cell reaction but had many more LECs on their anterior surface. Those IOLs associated with increased blood-aqueous barrier damage did not develop LECs. If an IOL is too biocompatible, then it may incite the growth of LECs over its surface, which could have disadvantages.

  2. Long-term corneal endothelial cell changes in pediatric intraocular lens reposition and exchange cases.

    PubMed

    Wang, Yan; Wu, Mingxing; Zhu, Liyuan; Liu, Yizhi

    2012-04-01

    To evaluate long-term corneal endothelial cell changes of intraocular lens (IOL) reposition and exchange in children. State key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, 510060, China In this retrospective study, all IOL reposition and exchange procedures performed in patients under 14 years old between January 1999 and April 2009 were included. Follow-up outcomes included corneal endothelial cell density, hexagonality, coefficient of variance, average cell size. IOL reposition procedures in 12 eyes (12 cases) (reposition group, RPG), and IOL exchanges in eight eyes (eight cases) (exchange group, EXG) were performed because of IOL pupillary capture or IOL dislocation. Median of follow-up was 44.5 months in RPG and 66.2 months in EXG. The density of corneal endothelial cells in RPG (2,053 ± 493/mm(2)) and EXG (2,100 ± 758/mm(2)) was significantly decreased in comparison to the control eyes (3,116 ± 335/mm(2)). Hexagonality of corneal endothelial cells and coefficient of variance showed no difference among the control group, RPG and EXG (P > 0.05). The density of corneal endothelial cells was conspicuously decreased after IOL reposition or exchange procedures in childhood cases. Longer follow-up must be conducted in these cases.

  3. Silicone intraocular lens surface calcification in a patient with asteroid hyalosis.

    PubMed

    Matsumura, Kazuhiro; Takano, Masahiko; Shimizu, Kimiya; Nemoto, Noriko

    2012-07-01

    To confirm a substance presence on the posterior intraocular lens (IOL) surface in a patient with asteroid hyalosis. An 80-year-old man had IOLs for approximately 12 years. Opacities and neodymium-doped yttrium aluminum garnet pits were observed on the posterior surface of the right IOL. Asteroid hyalosis and an epiretinal membrane were observed OD. An IOL exchange was performed on 24 March 2008, and the explanted IOL was analyzed using a light microscope and a transmission electron microscope with a scanning electron micrograph and an energy-dispersive X-ray spectrometer for elemental analysis. To confirm asteroid hyalosis, asteroid bodies were examined with the ionic liquid (EtMeIm+ BF4-) method using a field emission scanning electron microscope (FE-SEM) with digital beam control RGB mapping. X-ray spectrometry of the deposits revealed high calcium and phosphorus peaks. Spectrometry revealed that the posterior IOL surface opacity was due to a calcium-phosphorus compound. Examination of the asteroid bodies using FE-SEM with digital beam control RGB mapping confirmed calcium and phosphorus as the main components. Calcium hydrogen phosphate dihydrate deposits were probably responsible for the posterior IOL surface opacity. Furthermore, analysis of the asteroid bodies demonstrated that calcium and phosphorus were its main components.

  4. Least Squares Solution of Small Sample Multiple-Master PSInSAR System

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Ding, Xiao Li; Lu, Zhong

    2010-03-01

    In this paper we propose a least squares based approach for multi-temporal SAR interferometry that allows to estimate the deformation rate with no need of phase unwrapping. The approach utilizes a series of multi-master wrapped differential interferograms with short baselines and only focuses on the arcs constructed by two nearby points at which there are no phase ambiguities. During the estimation an outlier detector is used to identify and remove the arcs with phase ambiguities, and pseudoinverse of priori variance component matrix is taken as the weight of correlated observations in the model. The parameters at points can be obtained by an indirect adjustment model with constraints when several reference points are available. The proposed approach is verified by a set of simulated data.

  5. Time Analyzer for Time Synchronization and Monitor of the Deep Space Network

    NASA Technical Reports Server (NTRS)

    Cole, Steven; Gonzalez, Jorge, Jr.; Calhoun, Malcolm; Tjoelker, Robert

    2003-01-01

    A software package has been developed to measure, monitor, and archive the performance of timing signals distributed in the NASA Deep Space Network. Timing signals are generated from a central master clock and distributed to over 100 users at distances up to 30 kilometers. The time offset due to internal distribution delays and time jitter with respect to the central master clock are critical for successful spacecraft navigation, radio science, and very long baseline interferometry (VLBI) applications. The instrument controller and operator interface software is written in LabView and runs on the Linux operating system. The software controls a commercial multiplexer to switch 120 separate timing signals to measure offset and jitter with a time-interval counter referenced to the master clock. The offset of each channel is displayed in histogram form, and "out of specification" alarms are sent to a central complex monitor and control system. At any time, the measurement cycle of 120 signals can be interrupted for diagnostic tests on an individual channel. The instrument also routinely monitors and archives the long-term stability of all frequency standards or any other 1-pps source compared against the master clock. All data is stored and made available for

  6. Comparative evaluation of aspheric toric intraocular lens implantation and limbal relaxing incisions in eyes with cataracts and ≤3 dioptres of astigmatism.

    PubMed

    Lam, Douglas K T; Chow, Vanissa W S; Ye, Cong; Ng, Paul Ka-Fai; Wang, Zheng; Jhanji, Vishal

    2016-02-01

    To compare the visual outcomes of aspheric toric intraocular lens (IOL) implantation and limbal relaxing incisions (LRI) for management of coexisting age-related cataracts and astigmatism. In this prospective study, sixty eyes of 60 patients with visually significant cataract and coexisting corneal astigmatism ≤3 dioptres (D) were randomised to undergo phacoemulsification with either aspheric toric IOL or aspheric monofocal IOL with LRI. The main outcome measures were postoperative 3-month uncorrected visual acuity (UCVA), contrast sensitivity, rotational stability of the toric IOL and spectacle independence. The postoperative UCVA, contrast sensitivity and refractive astigmatism were significantly better than the baseline measurements for both groups (p≤0.001). There was no significant difference detected for these parameters between LRI and toric IOL groups postoperatively (p≥0.119). At both postoperative month 1 and 3, the percentages of eyes in need of spectacles were lower in toric group than LRI group (p≤0.030). IOL misalignment was noted in three eyes in the toric IOL group (mean misalignment 7.67±4.04°). On vector analysis, magnitude of error (ME) was negative in the LRI group indicating undercorrection, whereas the ME was close to zero for toric group. Both toric IOL implantation and LRI were effective in correcting corneal astigmatism ≤3 D during phacoemulsification, while LRI tended to undercorrect astigmatism. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. The Individual Virtual Eye: a Computer Model for Advanced Intraocular Lens Calculation

    PubMed Central

    Einighammer, Jens; Oltrup, Theo; Bende, Thomas; Jean, Benedikt

    2010-01-01

    Purpose To describe the individual virtual eye, a computer model of a human eye with respect to its optical properties. It is based on measurements of an individual person and one of its major application is calculating intraocular lenses (IOLs) for cataract surgery. Methods The model is constructed from an eye's geometry, including axial length and topographic measurements of the anterior corneal surface. All optical components of a pseudophakic eye are modeled with computer scientific methods. A spline-based interpolation method efficiently includes data from corneal topographic measurements. The geometrical optical properties, such as the wavefront aberration, are simulated with real ray-tracing using Snell's law. Optical components can be calculated using computer scientific optimization procedures. The geometry of customized aspheric IOLs was calculated for 32 eyes and the resulting wavefront aberration was investigated. Results The more complex the calculated IOL is, the lower the residual wavefront error is. Spherical IOLs are only able to correct for the defocus, while toric IOLs also eliminate astigmatism. Spherical aberration is additionally reduced by aspheric and toric aspheric IOLs. The efficient implementation of time-critical numerical ray-tracing and optimization procedures allows for short calculation times, which may lead to a practicable method integrated in some device. Conclusions The individual virtual eye allows for simulations and calculations regarding geometrical optics for individual persons. This leads to clinical applications like IOL calculation, with the potential to overcome the limitations of those current calculation methods that are based on paraxial optics, exemplary shown by calculating customized aspheric IOLs.

  8. [Millenniums update on posterior capsule opacification (PCO) scores, centration, biocompatibility and fixation of foldable intraocular lenses (IOL) - an analysis of 1,221 pseudophakic post mortem globes].

    PubMed

    Schmidbauer, J M; Vargas, L G; Apple, D J; Auffarth, G U; Peng, Q; Arthur, S N; Escobar-Gomez, M

    2001-10-01

    The ongoing and fast evolution of foldable IOL designs established the necessity to evaluate the different abilities of each lens style. The large IOL database (over 16,500 specimens) acquired in our laboratory, has permitted us to perform a clinico-pathological analysis on pseudophakic autopsy globes provided from sources worldwide, especially many Lions Eye banks in the United States. We analyzed 6 foldable IOL styles commonly implanted in the United States, using one type of rigid IOL design (1-piece design rigid PMMA optics) as a comparison group. Posterior capsule opacification (PCO) score, decentration, fixation, presence or absence of a Nd:YAG laser posterior capsulotomy and area and intensity of Soemmerring's ring formation was discerned by examination under an operating microscope using the Miyake-Apple posterior photographic technique. The four lenses with the lowest rates ranging between 3.8 % and 21.7 % are modern designs, mostly implanted after 1992. The two lenses with the higher rates ranging between 23.1 % and 30.4 %, were all older designs, already prevalent prior to 1992. IOL fixation with both haptics in the capsular bag showed the best centration values and PCO scores. Our studies to date have shown in a preliminary fashion that the AcrySoftrade mark IOL displays the the lowest (best) biocompatibility score. Entering the new millenium, with evolution of modern surgical techniques and IOL designs, the incidence of the two major complications of cataract surgery, decentration and PCO are now finally diminishing.

  9. Visual outcome and rotational stability of open loop toric intraocular lens implantation in Indian eyes

    PubMed Central

    Venkataraman, Arvind; Kalpana

    2013-01-01

    Purpose: To assess the visual outcome and rotational stability of single-piece open loop toric Intra Ocular Lens (IOL) in a clinical setting. Materials and Methods: In a prospective study, 122 eyes of 77 patients were followed up for a period of 12 months after cataract surgery with toric open loop IOL implantation. The pre-operative markings for the position of incision and IOL placement were done under slit lamp by anterior stromal puncture. The visual acuity, refraction, and IOL position were assessed at day 1, 1 week, 1 month, 3 months, 6 months, and 12 months after surgery. Results: The mean age of the cohort was 56 yrs (S.D. 13.88; range 16 to 87 years). The mean pre-operative cylinder of corneal astigmatism was 1.37 D. (SD 0.79, range 1.0 to 5.87 D). Mean post-operative refractive cylinder was 0.36 D (SD 0.57, range 0 to 1.50 D) at 12 months. Ninety-seven percent of the eyes were within 1 D of residual astigmatism. Ninety-four percent of patients had uncorrected visual acuity of 20/30 or better. Four eyes required IOL repositioning due to rotation. At 12 months, 96.7% of the IOLs were within 10 degrees of the target axis. There was no rotation seen after 6 months. Conclusion: Toric IOLs are very effective and consistent in correcting astigmatism during the cataract surgery. IOL rotation happens mostly within a month of surgery, and if significant, requires early repositioning. PMID:24343593

  10. Descemet membrane endothelial keratoplasty in cases with existing scleral-sutured and iris-sutured intraocular lenses

    PubMed Central

    2014-01-01

    Background To report two cases of Descemet Membrane Endothelial Keratoplasty (DMEK) in patients with existing scleral-fixated and iris-fixated intraocular lenses (sf-IOL and if-IOL, respectively). Case presentation DMEK procedures were performed on a 49-year-old woman with a pre-existing sf-IOL (case 1) and a 69-year-old woman with a pre-existing if-IOL (case 2) in order to treat secondary corneal edema due to pseudophakic bullous keratopathy. Visual acuity, refractive error, intraocular pressure, slit lamp examination, pachymetry measurements and endothelial cell density (ECD) were considered and repeated during follow-ups. Both cases had no intraoperative complications. At postoperative day 1 graft centration and complete attachment were noted. The IOL positions were unchanged in comparison to their preoperative positions. In case 1, visual acuity improved from 1/15 at 1 meter preoperative to 20/200 within one week and to 20/63 within 12 weeks of follow up. In case 2, visual acuity improved from counting fingers at 1 meter preoperative to 20/200 within one week and to 20/100 within 12 weeks of follow-up. In case 2 a partial graft dislocation was observed at postoperative day twenty. Complete graft re-apposition was achieved by rebubbling procedure performed with intracameral air injection. Conclusions DMEK surgery in the treatment of pseudophakic bullous keratopathy in the presence of sf-IOL and if-IOL can successfully be performed. These eyes are at increased risk of IOL dislocation into the vitreous cavity during DMEK surgery. PMID:24443809

  11. RGD Surface Functionalization of the Hydrophilic Acrylic Intraocular Lens Material to Control Posterior Capsular Opacification

    PubMed Central

    Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine

    2014-01-01

    Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development. PMID:25501012

  12. RGD surface functionalization of the hydrophilic acrylic intraocular lens material to control posterior capsular opacification.

    PubMed

    Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine

    2014-01-01

    Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development.

  13. Blue-light filtering intraocular lenses (IOLs) for protecting macular health.

    PubMed

    Downie, Laura E; Busija, Ljoudmila; Keller, Peter R

    2018-05-22

    An intraocular lens (IOL) is a synthetic lens that is surgically implanted within the eye following removal of the crystalline lens, during cataract surgery. While all modern IOLs attenuate the transmission of ultra-violet (UV) light, some IOLs, called blue-blocking or blue-light filtering IOLs, also reduce short-wavelength visible light transmission. The rationale for blue-light filtering IOLs derives primarily from cell culture and animal studies, which suggest that short-wavelength visible light can induce retinal photoxicity. Blue-light filtering IOLs have been suggested to impart retinal protection and potentially prevent the development and progression of age-related macular degeneration (AMD). We sought to investigate the evidence relating to these suggested benefits of blue-light filtering IOLs, and to consider any potential adverse effects. To assess the effects of blue-light filtering IOLs compared with non-blue-light filtering IOLs, with respect to providing protection to macular health and function. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 9); Ovid MEDLINE; Ovid Embase; LILACS; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 25 October 2017. We included randomised controlled trials (RCTs), involving adult participants undergoing cataract extraction, where a blue-light filtering IOL was compared with an equivalent non-blue-light filtering IOL. The prespecified primary outcome was the change in distance best-corrected visual acuity (BCVA), as a continuous outcome, between baseline and 12 months of follow-up. Prespecified secondary outcomes included postoperative contrast sensitivity, colour discrimination, macular pigment optical density (MPOD), proportion of eyes with a pathological finding at the macula (including, but not limited to the development or progression of AMD, or both), daytime alertness, reaction time and patient satisfaction. We evaluated findings related to ocular and systemic adverse effects.Two review authors independently screened abstracts and full-text articles, extracted data from eligible RCTs and judged the risk of bias using the Cochrane tool. We reached a consensus on any disagreements by discussion. Where appropriate, we pooled data relating to outcomes and used random-effects or fixed-effect models for the meta-analyses. We summarised the overall certainty of the evidence using GRADE. We included 51 RCTs from 17 different countries, although most studies either did not report relevant outcomes, or provided data in a format that could not be extracted. Together, the included studies considered the outcomes of IOL implantation in over 5000 eyes. The number of participants ranged from 13 to 300, and the follow-up period ranged from one month to five years. Only two of the studies had a trial registry record and no studies referred to a published protocol. We did not judge any of the studies to have a low risk of bias in all seven domains. We judged approximately two-thirds of the studies to have a high risk of bias in domains relating to 'blinding of participants and personnel' (performance bias) and 'blinding of outcome assessment' (detection bias).We found with moderate certainty, that distance BCVA with a blue-light filtering IOL, at six to 18 months postoperatively, and measured in logMAR, was not clearly different to distance BCVA with a non-blue-light filtering IOL (mean difference (MD) -0.01 logMAR, 95% confidence interval (CI) -0.03 to 0.02, P = 0.48; 2 studies, 131 eyes).There was very low-certainty evidence relating to any potential inter-intervention difference for the proportion of eyes that developed late-stage AMD at three years of follow-up, or any stage of AMD at one year of follow-up, as data derived from one trial and two trials respectively, and there were no events in either IOL intervention group, for either outcome. There was very low-certainty evidence for the outcome for the proportion of participants who lost 15 or more letters of distance BCVA at six months of follow-up; two trials that considered a total of 63 eyes reported no events, in either IOL intervention group.There were no relevant, combinable data available for outcomes relating to the effect on contrast sensitivity at six months, the proportion of eyes with a measurable loss of colour discrimination from baseline at six months, or the proportion of participants with adverse events with a probable causal link with the study interventions after six months.We were unable to draw reliable conclusions on the relative equivalence or superiority of blue-light filtering IOLs versus non-blue-light filtering IOLs in relation to longer-term effects on macular health. We were also not able to determine with any certainty whether blue-light filtering IOLs have any significant effects on MPOD, contrast sensitivity, colour discrimination, daytime alertness, reaction time or patient satisfaction, relative to non-blue-light filtering IOLs. This systematic review shows with moderate certainty that there is no clinically meaningful difference in short-term BCVA with the two types of IOLs. Further, based upon available data, these findings suggest that there is no clinically meaningful difference in short-term contrast sensitivity with the two interventions, although there was a low level of certainty for this outcome due to a small number of included studies and their inherent risk of bias. Based upon current, best-available research evidence, it is unclear whether blue-light filtering IOLs preserve macular health or alter risks associated with the development and progression of AMD, or both. Further research is required to fully understand the effects of blue-light filtering IOLs for providing protection to macular health and function.

  14. 42 CFR 416.185 - Process for establishing a new class of new technology IOLs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... technology IOLs. 416.185 Section 416.185 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT... Adjustment in Payment Amounts for New Technology Intraocular Lenses Furnished by Ambulatory Service Centers § 416.185 Process for establishing a new class of new technology IOLs. (a) Announcement of deadline for...

  15. 42 CFR 416.195 - Determination of membership in new classes of new technology IOLs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... technology IOLs. 416.195 Section 416.195 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT... Adjustment in Payment Amounts for New Technology Intraocular Lenses Furnished by Ambulatory Service Centers § 416.195 Determination of membership in new classes of new technology IOLs. (a) Factors to be...

  16. 42 CFR 416.185 - Process for establishing a new class of new technology IOLs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... technology IOLs. 416.185 Section 416.185 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT... Adjustment in Payment Amounts for New Technology Intraocular Lenses Furnished by Ambulatory Service Centers § 416.185 Process for establishing a new class of new technology IOLs. (a) Announcement of deadline for...

  17. 42 CFR 416.195 - Determination of membership in new classes of new technology IOLs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... technology IOLs. 416.195 Section 416.195 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT... Adjustment in Payment Amounts for New Technology Intraocular Lenses Furnished by Ambulatory Service Centers § 416.195 Determination of membership in new classes of new technology IOLs. (a) Factors to be...

  18. 42 CFR 416.195 - Determination of membership in new classes of new technology IOLs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... technology IOLs. 416.195 Section 416.195 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT... Payment Amounts for New Technology Intraocular Lenses Furnished by Ambulatory Service Centers § 416.195 Determination of membership in new classes of new technology IOLs. (a) Factors to be considered. CMS uses the...

  19. 42 CFR 416.185 - Process for establishing a new class of new technology IOLs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... technology IOLs. 416.185 Section 416.185 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT... Payment Amounts for New Technology Intraocular Lenses Furnished by Ambulatory Service Centers § 416.185 Process for establishing a new class of new technology IOLs. (a) Announcement of deadline for requests for...

  20. Surface Modification of Intraocular Lenses

    PubMed Central

    Huang, Qi; Cheng, George Pak-Man; Chiu, Kin; Wang, Gui-Qin

    2016-01-01

    Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs). Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol), polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO2, heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs. PMID:26830993

  1. Identification of the source of permanent glare from a three-piece IOL.

    PubMed

    Wolffe, M; Landry, R J; Alpar, J J

    2007-08-01

    To identify the source of unwanted glare images from a three-piece intraocular lens (IOL) implant following cataract surgery. The IOL and posterior capsule were examined under mydriatic and nonmydriatic conditions using direct focal illumination from a slit lamp biomicroscope. Direct focal illumination was undertaken with both a narrow beam (0.1 mm in width) and small spot (0.1 mm in diameter) to identify the points at which the glare images were stimulated. While observing the location of the beam with the slit lamp biomicroscope, the patient indicated when the glare images were stimulated. The nasal haptic insertion into the optic was identified as the source of temporal line images arising from lights such as headlamps from oncoming cars and street lamps. The adjacent edge of the IOL was also identified as the likely source of additional cob web-like light rays. The haptic insertions in three-piece IOLs may, under certain conditions, interfere with light entering the pupil and produce extraneous images. Large mesopic pupils and decentred IOLs are conditions that increase the likelihood of unwanted glare images.

  2. Lessons learned: wrong intraocular lens.

    PubMed

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. Scanning electron microscopy analysis of a sputnik-like intraocular lens 28 years after implantation.

    PubMed

    Ferrer, Consuelo; Abu-Mustafa, Sabat K; Alió, Jorge L

    2009-09-01

    To report a pupil-supported, iris-clip intraocular lens (IOL) that was explanted more than 28 years after implantation. A pupil-supported, iris-clip, Sputnik-like IOL was implanted in the left eye of a 33-year-old man to correct aphakia after extracapsular cataract extraction due to trauma. Twenty-eight years after implantation, the patient was referred to our center with loss of vision. Clinical examination showed dislocation of the IOL, which was subsequently explanted. Scanning electron microscopic examination showed a transparent, polymethylmethacrylate (PMMA), pupil-supported, iris-clip IOL with melanosomes and cell deposits (foreign-body reaction) on its surface. This case demonstrates the inertness of PMMA material and reports that a foreign body reaction can be induced following IOL dislocation 28 years after implantation. Copyright 2009, SLACK Incorporated.

  4. Phacoemulsification and implantation of an accommodating IOL after PRK.

    PubMed

    Aslanides, loannis M; Plainis, Sotiris; Kumar, Vinod; Ginis, Harilaos

    2006-01-01

    To present a case of phacoemulsification and implantation of an accommodating intraocular lens (IOL) in a patient with cataract formation after previous refractive surgery. A 50-year-old man, who initially had photorefractive keratectomy to correct moderate myopia, developed a cataract in one eye. He subsequently underwent phacoemulsification and implantation of a 1CU accommodating IOL, as he wished to remain spectacle independent. The patient's distance vision was fully restored. However, accommodative function, which was assessed using subjective and novice objective techniques, was only partially restored. Although the accommodating IOL fully restored the patient's distance vision, accommodative function was only partially restored.

  5. Extracapsular cataract extraction with and without intra-ocular lenses in black patients.

    PubMed

    Welsh, N H

    1992-04-04

    Cataracts are the commonest cause of blindness in Third-World countries and cataract extraction is the commonest eye operation performed anywhere. Patients require optical correction after surgery either in the form of an intra-ocular lens (IOL) or bifocal aphakic glasses. The standard operative procedure in First-World countries is an extracapsular cataract extraction with an IOL. This type of operation has been thought to be contraindicated in black patients because of the complications and lack of adequate postoperative follow-up. During 1987-1989 3,144 cataract extractions, of which 2,157 were simple extracapsular extractions and 987 had IOLs inserted, were performed at the above hospitals. The two groups were compared for complications and visual results. The complications were similar in both groups and were acceptable, therefore posterior lens implantation confers no additional risk on routine extracapsular cataract extraction. The visual results in the IOL group with and without additional glasses were compared with those patients who had correcting aphakic glasses. In the corrected IOL group, 98% of patients saw better than 6/24, whereas in the aphakic spectacle group, 87.5% saw 6/24 or better. Since the majority of black patients cannot afford costly prescribed spectacles, it was important to analyse the visual acuity in patients who had IOLs and were uncorrected; 81.6% saw 6/24 or better. IOLs in black patients are therefore indicated but the disadvantage is the cost.

  6. Comparison of OVD and BSS for Maintaining the Anterior Chamber during IOL Implantation

    PubMed Central

    Lee, Ho Young; Choy, Yoon Jung

    2011-01-01

    Purpose To compare surgical results between conventional intraocular lens (IOL) implantation using an ophthalmic viscosurgical device (OVD) and IOL implantation using a balanced salt solution (BSS) after irrigation/aspiration (I/A) of the lens cortex. Methods A randomized prospective study was conducted on 62 patients who underwent cataract surgery. Following completion of conventional I/A of the lens cortex, we divided patients into two groups according to whether or not BSS was used. In group A (n = 31), the anterior chamber and the capsular bag were completely filled with an OVD before IOL implantation. On the other hand, in group B (n = 31), BSS was irrigated into the anterior chamber through a previous side port during IOL implantation. Surgical results were compared between the two groups. Results In both groups, IOP peaked six hours after surgery. The occurrence of an IOP spike by postoperative day one was observed in six cases (6 / 31) in group A and in no cases (0 / 31) in group B, a difference that was statistically significant (p = 0.024). The values of endothelial cell density, central corneal thickness, anterior chamber inflammation, myopic shift, and posterior capsule opacification were not significantly different between the two groups. Conclusions Compared with the use of OVD for IOL implantation, use of BSS during IOL implantation resulted in reductions in postoperative IOP spike and OVD removal time. PMID:21350689

  7. Retropupillary iris-claw intraocular lens for the surgical correction of aphakia in cases with microspherophakia.

    PubMed

    Fouda, Sameh Mosaad; Al Aswad, Mahmoud A; Ibrahim, Basem M; Bori, Ashraf; Mattout, Hala K

    2016-12-01

    This study aimed to evaluate the safety and efficacy of retropupillary fixation of an iris-claw intraocular lens (IOL; Verisyse polymethyl methacrylate IOL, Abbott Medical Optics [AMO], Netherlands) for the surgical correction of aphakia in microspherophakic eyes without sufficient capsular support. This was a prospective, interventional, noncomparative case series. This interventional case series comprised 17 eyes of 9 microspherophakic patients. Retropupillary fixation of the Verisyse iris-claw IOL (AMO) was performed in all cases. The surgical time was measured. Corrected distance visual acuity, astigmatism, intraocular pressure (IOP), tissue reaction, pigment dispersion, and stability of the IOL were studied 1 day, 3 days, 1 week, 2 weeks, 1 month, and 6 months postoperatively. Eight patients had familial microspherophakia and one patient had Marfan's syndrome. Eighty-two percent of the cases achieved a visual acuity of 0.3 or better. There was no significant postoperative inflammatory reaction. Transient elevation of IOP was recorded in two cases in the 1st week only. One IOL developed disengagement of one of the haptics from the iris and was successfully re-engaged. All the other IOLs were well centered and stable. The mean surgical time was 18.0 ± 4.5 min. Retropupillary fixation of an iris-claw IOL is a safe and effective procedure that provides early visual recovery. It is also a time-saving method for correcting aphakia in microspherophakic eyes without sufficient capsular support.

  8. Toric Intraocular Lens for Astigmatism Correction in Cataract Patients.

    PubMed

    Razmjoo, Hassan; Ghoreishi, Mohammad; Milasi, Azadeh Mohammadi; Peyman, Alireza; Jafarzadeh, Zahra; Mohammadinia, Mohadeseh; Kobra, Nasrollahi

    2017-01-01

    To assess the clinical consequences of AcrySof toric intraocular lens (IOL) and Hoya toric IOL implantation to correct preexisting corneal astigmatism in patients undergoing cataract surgery. In this study, we examined 55 eyes of 45 patients with at least 1.00 D corneal astigmatism who were scheduled for cataract surgery. After phacoemulsification, toric IOL was inserted and axis was aligned. We observed the patients, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, manifest refraction, and IOL axis alignment 6 months after surgery. After 6 months, the UDVA was 0.17 ± 0.17 logMAR in the AcrySof group and 0.17 ± 0.18 logMar in the Hoya group. More than 78% of eyes in the AcrySof group and 80% of eyes in the Hoya toric IOL achieved a UDVA of 20/40 or better. In the AcrySof group, the mean preoperative corneal astigmatism was 2.73 ± 0.92 D. The mean postoperative refractive astigmatism was 0.84 ± 0.63 D. In the Hoya group, the preoperative corneal astigmatism was 2.58 ± 0.76 D and the postoperative refractive astigmatism was 0.87 ± 0.66 D ( P < 0.05). The mean AcrySof IOL axis rotation was 1.88° ± 3.05°. In the Hoya group, the mean axis rotation was 1.53° ± 3.66°. All changes in visual and refractive data before and after surgery were statistically significant ( P < 0.05). There was no significant difference between the two groups regarding refractive and visual outcome after surgery ( P > 0.05 for all). Implantation of AcrySof toric IOL and Hoya toric IOL was an effective way to correct preexisting corneal astigmatism in cataract surgery.

  9. Comparison of astigmatism correction using either peripheral corneal relaxing incisions or toric intraocular lenses.

    PubMed

    Muftuoglu, Ilkay Kilic; Aydin Akova, Yonca; Aksoy, Sibel; Unsal, Erkan

    2016-01-01

    To compare the efficacy and short-term stability of toric intraocular lenses (tIOL) and peripheral cornea relaxing incisions (PCRI) during phacoemulsification. Patients with preexisting corneal astigmatism had cataract surgery either with tIOL (AcrySof Toric) (39 eyes of 35 patients) or standard intraocular lens (AcrySof) + PCRIs (38 eyes of 33 patients). Patients were retrospectively evaluated for manifest refraction, corneal topography, and uncorrected and corrected visual acuities preoperatively and at postoperative 1 and 6 months. The Alpins vectorial method was used to analyze the target induced astigmatism (TIA) and surgically induced astigmatism (SIA), magnitude of error (the difference between the magnitude of SIA and TIA) (ME), and correction index. Mean preoperative corneal astigmatism was 2.21 ± 1.32 D in the tIOL group and 2.24 ± 0.96 D in the PCRI group; the difference was not significant. The decrease in astigmatism was significant in both groups at last follow-up (64% tIOL group, 32% PCRI group, p<0.01, Wilcoxon signed rank test). The mean remaining refractive astigmatism was significantly higher in the PCRI group than in the tIOL group at 1-month (1.42 ± 1.22, 0.89 ± 0.68, respectively) and 6-month follow-ups (1.75 ± 1.37 D, 0.92 ± 0.72, respectively) (p<0.01). The mean ME was significantly lower (-0.35 versus -0.88) with a higher correction index (0.96 versus 0.56) in the tIOL group at 6 months postoperatively. Both tIOL implantation and using PCRI were effective methods to reduce preoperative astigmatism at the time of the cataract surgery. However, tIOLs provided better remaining astigmatism with a more stable refraction than PCRI.

  10. Microincision bimanual phacoemulsification and Thinoptx implantation through a 1.70 mm incision.

    PubMed

    Prakash, P; Kasaby, H E; Aggarwal, R K; Humfrey, S

    2007-02-01

    To prospectively assess the efficacy of bimanual phacoemulsification and implantation of Thinoptx, an injectable intraocular lens (IOL), inserted through 1.70 mm clear corneal incision. Department of Ophthalmology, Southend Hospital NHS Trust, UK. A total of 50 eyes of 49 randomly selected patients with cataracts had microincision clear corneal bimanual phacoemulsification (MICS) with implantation of Thinoptx IOL in the capsular bag. All patients underwent full preoperative assessment. Postoperative assessment was carried out at 3 and 6 weeks and at 15 months. In all 50 cases the IOL was inserted through 1.70 mm clear corneal incision. The mean best-corrected visual acuity was 0.02 (6/6-1) at 6 weeks and was 0.17 (6/10) at the final follow-up. The mean final surgically induced astigmatism at 6 weeks was 0.0106. Coloured haloes around artificial lights were perceived by 69.23% of patients at 6 weeks and by 61.29% at the final follow-up. One patient underwent IOL exchange for this. Posterior capsular opacification was noticed in 31.26% at 6 weeks and in 64.51% at 15 months. Anterior capsular opacification was noticed in 5.26% at 6 weeks and in 16.12% at 15 months. In one patient the IOL had to be exchanged because of tilt and displacement of the IOL due to anterior capsular phimosis. We conclude Thinoptx can be safely inserted through 1.70 mm incision used for bimanual phacoemulsification. Distance and near visual acuity achieved with this IOL is satisfactory. There is no significant change in keratometric astigmatism following this procedure. However, posterior capsular opacification rate was significantly higher with this IOL. Haloes around light sources were significant.

  11. Variation in hospital rates of induction of labour: a population-based record linkage study.

    PubMed

    Nippita, Tanya A; Trevena, Judy A; Patterson, Jillian A; Ford, Jane B; Morris, Jonathan M; Roberts, Christine L

    2015-09-02

    To examine interhospital variation in rates of induction of labour (IOL) to identify potential targets to reduce high rates of practice variation. Population-based record linkage cohort study. New South Wales, Australia, 2010-2011. All women with live births of ≥24 weeks gestation in 72 hospitals. Variation in hospital IOL rates adjusted for differences in case-mix, according to 10 mutually exclusive groups derived from the Robson caesarean section classification; groups were categorised by parity, plurality, fetal presentation, prior caesarean section and gestational age. The overall IOL rate was 26.7% (46,922 of 175,444 maternities were induced), ranging from 9.7% to 41.2% (IQR 21.8-29.8%) between hospitals. Nulliparous and multiparous women at 39-40 weeks gestation with a singleton cephalic birth were the greatest contributors to the overall IOL rate (23.5% and 20.2% of all IOL respectively), and had persisting high unexplained variation after adjustment for case-mix (adjusted hospital IOL rates ranging from 11.8% to 44.9% and 7.1% to 40.5%, respectively). In contrast, there was little variation in interhospital IOL rates among multiparous women with a singleton cephalic birth at ≥41 weeks gestation, women with singleton non-cephalic pregnancies and women with multifetal pregnancies. 7 of the 10 groups showed high or moderate unexplained variation in interhospital IOL rates, most pronounced for women at 39-40 weeks gestation with a singleton cephalic birth. Outcomes associated with divergent practice require determination, which may guide strategies to reduce practice variation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    PubMed

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  13. Correlating optical bench performance with clinical defocus curves in varifocal and trifocal intraocular lenses.

    PubMed

    Plaza-Puche, Ana B; Alió, Jorge L; MacRae, Scott; Zheleznyak, Len; Sala, Esperanza; Yoon, Geunyoung

    2015-05-01

    To investigate the correlations existing between a trifocal intraocular lens (IOL) and a varifocal IOL using the "ex vivo" optical bench through-focus image quality analysis and the clinical visual performance in real patients by study of the defocus curves. This prospective, consecutive, nonrandomized, comparative study included a total of 64 eyes of 42 patients. Three groups of eyes were differentiated according to the IOL implanted: 22 eyes implanted with the varifocal Lentis Mplus LS-313 IOL (Oculentis GmbH, Berlin, Germany); 22 eyes implanted with the trifocal FineVision IOL (Physiol, Liege, Belgium), and 20 eyes implanted with the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Visual outcomes and defocus curve were evaluated postoperatively. Optical bench through-focus performance was quantified by computing an image quality metric and the cross-correlation coefficient between an unaberrated reference image and captured retinal images from a model eye with a 3.0-mm artificial pupil. Statistically significant differences among defocus curves of different IOLs were detected for the levels of defocus from -4.00 to -1.00 diopters (D) (P < .01). Significant correlations were found between the optical bench image quality metric results and logMAR visual acuity scale in all groups (Lentis Mplus group: r = -0.97, P < .01; FineVision group: r = -0.82, P < .01; Acrys of group: r = -0.99, P < .01). Linear predicting models were obtained. Significant correlations were found between logMAR visual acuity and image quality metric for the multifocal and monofocal IOLs analyzed. This finding enables surgeons to predict visual outcomes from the optical bench analysis. Copyright 2015, SLACK Incorporated.

  14. Negative dysphotopsia: Causes and rationale for prevention and treatment.

    PubMed

    Holladay, Jack T; Simpson, Michael J

    2017-02-01

    To determine the cause of negative dysphotopsia using standard ray-tracing techniques and identify the primary and secondary causative factors. Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA. Experimental study. Zemax ray-tracing software was used to evaluate pseudophakic and phakic eye models to show the location of retinal field images from various visual field objects. Phakic retinal field angles (RFAs) were used as a reference for the perceived field locations for retinal images in pseudophakic eyes. In a nominal acrylic pseudophakic eye model with a 2.5 mm diameter pupil, the maximum RFA from rays refracted by the intraocular lens (IOL) was 85.7 degrees and the minimum RFA for rays missing the optic of the IOL was 88.3 degrees, leaving a dark gap (shadow) of 2.6 degrees in the extreme temporal field. The width of the shadow was more prominent for a smaller pupil, a larger angle kappa, an equi-biconvex or plano-convex IOL shape, and a smaller axial distance from iris to IOL and with the anterior capsule overlying the nasal IOL. Secondary factors included IOL edge design, material, diameter, decentration, tilt, and aspheric surfaces. Standard ray-tracing techniques showed that a shadow is present when there is a gap between the retinal images formed by rays missing the optic of the IOL and rays refracted by the IOL. Primary and secondary factors independently affected the width and location of the gap (or overlap). The ray tracing also showed a constriction and double retinal imaging in the extreme temporal visual field. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Effect of the equivalent refractive index on intraocular lens power prediction with ray tracing after myopic laser in situ keratomileusis.

    PubMed

    Canovas, Carmen; van der Mooren, Marrie; Rosén, Robert; Piers, Patricia A; Wang, Li; Koch, Douglas D; Artal, Pablo

    2015-05-01

    To determine the impact of the equivalent refractive index (ERI) on intraocular lens (IOL) power prediction for eyes with previous myopic laser in situ keratomileusis (LASIK) using custom ray tracing. AMO B.V., Groningen, the Netherlands, and the Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA. Retrospective data analysis. The ERI was calculated individually from the post-LASIK total corneal power. Two methods to account for the posterior corneal surface were tested; that is, calculation from pre-LASIK data or from post-LASIK data only. Four IOL power predictions were generated using a computer-based ray-tracing technique, including individual ERI results from both calculation methods, a mean ERI over the whole population, and the ERI for normal patients. For each patient, IOL power results calculated from the four predictions as well as those obtained with the Haigis-L were compared with the optimum IOL power calculated after cataract surgery. The study evaluated 25 patients. The mean and range of ERI values determined using post-LASIK data were similar to those determined from pre-LASIK data. Introducing individual or an average ERI in the ray-tracing IOL power calculation procedure resulted in mean IOL power errors that were not significantly different from zero. The ray-tracing procedure that includes an average ERI gave a greater percentage of eyes with an IOL power prediction error within ±0.5 diopter than the Haigis-L (84% versus 52%). For IOL power determination in post-LASIK patients, custom ray tracing including a modified ERI was an accurate procedure that exceeded the current standards for normal eyes. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    PubMed Central

    Piñero, David P.; Camps, Vicente J.; Ramón, María L.; Mateo, Verónica; Pérez-Cambrodí, Rafael J.

    2015-01-01

    AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). RESULTS PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors. PMID:26085998

  17. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    PubMed

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  18. Opacification of AcriFlex 50CSE hydrophilic acrylic intraocular lenses.

    PubMed

    Lim, Andrew Keat Eu; Goh, Pik Pin; Azura, Ramlee; Mariam, Ismail

    2011-04-01

    To determine the prevalence of and risk factors for AcriFlex 50CSE hydrophilic acrylic intraocular lens (IOL) opacification approximately 3 years after implantation. Selayang Hospital, Selangor, Malaysia. Cross-sectional study. Patients who had AcriFlex 50CSE IOL implantation in 2005 and 2006 were identified from operating logbooks and recalled via telephone and letters. Opaque IOLs were explanted and sent for scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS). The review showed that 18 patients had died and 67 had declined examination or could not be contacted, leaving 239 eyes for evaluation. The age of the patients ranged from 25 to 85 years. Of the patients, 83 (34.7%) were Malay, 127 (53.1%) Chinese, and 29 (12.1%) East Indian. The male:female ratio was 1:1. Fourteen eyes of 13 patients (5.4%) had IOL opacification; 1 had bilateral opacification. Five eyes had fine deposits, and 9 eyes had dense opaque deposits. Seven opaque IOLs required explantation. There was no correlation between age (P=.645), sex (P=.319), or race (P=.860) and IOL opacification. Pearson chi-square analysis showed a strong association between diabetes mellitus and IOL opacification (P=.019). Nine (69.2%) of the 13 patients with opacification had diabetes. Scanning electron microscopy and EDS showed calcium and phosphate deposits on the optic surface and intralenticularly near the anterior surface of the optic. Results indicate that diabetes mellitus is a risk factor for AcriFlex hydrophilic acrylic IOL opacification. In some cases, opacification affected vision, necessitating explantation. The pathophysiology of this complication is unknown. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Macroporous Inverse Opal-like MoxC with Incorporated Mo Vacancies for Significantly Enhanced Hydrogen Evolution.

    PubMed

    Li, Feng; Zhao, Xianglong; Mahmood, Javeed; Okyay, Mahmut Sait; Jung, Sun-Min; Ahmad, Ishfaq; Kim, Seok-Jin; Han, Gao-Feng; Park, Noejung; Baek, Jong-Beom

    2017-07-25

    The hydrogen evolution reaction (HER) is one of the most important pathways for producing pure and clean hydrogen. Although platinum (Pt) is the most efficient HER electrocatalyst, its practical application is significantly hindered by high-cost and scarcity. In this work, an Mo x C with incorporated Mo vacancies and macroporous inverse opal-like (IOL) structure (Mo x C-IOL) was synthesized and studied as a low-cost efficient HER electrocatalyst. The macroporous IOL structure was controllably fabricated using a facile-hard template strategy. As a result of the combined benefits of the Mo vacancies and structural advantages, including appropriate hydrogen binding energy, large exposed surface, robust IOL structure and fast mass/charge transport, the synthesized Mo x C-IOL exhibited significantly enhanced HER electrocatalytic performance with good stability, with performance comparable or superior to Pt wire in both acidic and alkaline solutions.

  20. Treatment of dystrophic calcification on a silicone intraocular lens with pars plana vitrectomy

    PubMed Central

    Mehta, Nitish; Goldberg, Roger A; Shah, Chirag P

    2014-01-01

    Purpose Dense, vision-obscuring calcification on the posterior aspect of silicone intraocular lenses (IOLs) is often not amenable to neodymium:yttrium-aluminum-garnet capsulotomy, and, in prior reports, has required IOL exchange. We report the successful removal of dense calcium deposition on the posterior surface of a three-piece silicone lens using pars plana vitrectomy (PPV). Materials and methods A 23-gauge PPV was performed using the Stellaris® vitrectomy system. A light pipe was used to retroilluminate the IOL, and a dense fibrous tissue setting with a low cut-rate and high aspiration rate was able to clear the visual axis of the dystrophic calcification without damaging the IOL optic. Results Visual acuity improved from 20/100 to 20/25. Conclusion Small-gauge PPV may be utilized to remove dense dystrophic calcium deposits on the lens surface in lieu of IOL exchange. PMID:25045246

  1. Sectioning a luxated intraocular lens inside the vitreous cavity.

    PubMed

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. [Implantation of intraocular lenses in the ciliary sulcus].

    PubMed

    Schulze, S; Bertelmann, T; Sekundo, W

    2014-04-01

    Implantation of an intraocular lens (IOL) into the ciliary sulcus is the second most common implantation site after the regular capsular bag (in the bag) placement of an IOL. Although mainly not primarily intended, it is very often used in both complicated cataract surgery and secondary implantation due to IOL dislocation or aphakia. In most cases stable positioning is possible, especially when using optic capture techniques. A variety of difficulties can occur with sulcus implantation depending on the anatomical and surgical conditions present at the time of implantation. The most anterior position of the sulcus lense has to be considered for calculation of the refractive power of the IOL.

  3. [Scheimpflug photography for the examination of phakic intraocular lenses].

    PubMed

    Baumeister, M

    2014-10-01

    High myopia phakic intraocular lenses (IOL) have become an established means of surgical correction for high ametropia. Scheimpflug photography is one of the methods which are frequently applied for postoperative examination of the implants. Results from published studies employing Scheimpflug photography for examination of anterior chamber angle-fixated, iris-fixated and sulcus-fixated phakic IOLs were evaluated. In several published studies Scheimpflug photography was used to examine the position of the implant and opacification of the crystalline lens. The results provided valuable evidence for the improvement of phakic IOL design. Scheimpflug photography offers an easy to use, rapid non-contact examination of phakic IOLs.

  4. Glued intraocular lens implantation for eyes with inadequate capsular support: Analysis of the postoperative visual outcome.

    PubMed

    Mohan, Sujatha; John, Bina; Rajan, Mohan; Malkani, Harsha; Nagalekshmi, S V; Singh, Siddhartha

    2017-06-01

    The aim of this study is to analyze the postoperative visual outcomes of fibrin glue-assisted, suture-less posterior chamber (PC) intraocular lens (IOL) implantation technique in eyes with inadequate capsule support at a tertiary eye care hospital in South India. This is a retrospective, nonrandomized case series. This study analyzes 94 eyes which underwent PC-IOL implantation by fibrin glue-assisted, suture-less technique. All patients who had IOL implants by the fibrin glue-assisted PC-IOL technique from August 2009 to January 2014 were included in the study. Intra- and post-operative complications were analyzed. The postoperative best spectacle-corrected visual acuity (BSCVA) was evaluated and recorded at the end of 6 months. The data were analyzed using SPSS version 16.1 (SPSS Inc., Chicago, Illinois, USA) using two sample paired t-test and independent t-test. A total of 94 eyes of 92 patients that underwent glued IOL implantation over a period of 5 years were analyzed. Out of 94 eyes, 77 eyes (84.6%) maintained or improved on their preoperative BSCVA (P = 0.012). We conclude that glued IOL implantation is a feasible option in rehabilitating patients with aphakia without adequate capsular support.

  5. INTRAOCULAR LENS POSITION IN COMBINED PHACOEMULSIFICATION AND VITREORETINAL SURGERY.

    PubMed

    Ozates, Serdar; Kiziltoprak, Hasan; Koc, Mustafa; Uzel, Mehmet Murat; Teke, Mehmet Yasin

    2017-10-09

    To assess the decentration and angle of tilt of the intraocular lens (IOL) according to the intravitreal tamponade types used in combined phacoemulsification and vitreoretinal surgery. This prospective and randomized clinical study involved 73 eyes of 69 patients who underwent combined vitreoretinal surgery. Eyes with intravitreal tamponades formed the study group and eyes without intravitreal tamponades formed the control group. The study group was further divided into silicone oil and gas tamponade subgroups. Cross-sectional IOL images were captured using a Pentacam HR (Oculus, Germany) and tilt and decentration were calculated with Adobe Photoshop software (Adobe, San Jose, CA). The mean angle of tilt and decentration at the vertical meridian were significantly higher in both tamponade groups than in the control group (P < 0.05 for all). No significant difference was observed among the groups regarding IOL position parameters at the horizontal meridian (P > 0.05). When comparing the silicone oil and gas tamponade subgroups, no significant differences were noted on the position of IOL at both meridians (P > 0.05 for all). Intravitreal tamponades have an important effect on the position of IOL in combined vitreoretinal surgery. Silicone oil and gas tamponades may induce postoperative tilt and decentration of one-piece acrylic IOLs.

  6. Differences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers.

    PubMed

    Nakajima, Masashi; Hiraoka, Takahiro; Yamamoto, Toshiya; Takagi, Seiu; Hirohara, Yoko; Oshika, Tetsuro; Mihashi, Toshifumi

    2016-01-01

    Several researchers have studied the longitudinal chromatic aberration (LCA) of eyes implanted with an intraocular lens (IOL). We investigated the LCA of eyes implanted with yellow-colored IOLs from three different manufacturers: Alcon Inc., HOYA Corp., and AMO Inc. The number of subjects was 11, 16, and 16, respectively. The LCA of eyes implanted with SN60WF and SN60AT (Alcon Inc.), and with XY-1 (HOYA Corp.), was the same as that of phakic eyes. The LCA of eyes with ZCB00V (AMO Inc.) was smaller than that of phakic eyes. The LCA of eyes implanted with Alcon's and HOYA's IOLs, but not the LCA of eyes implanted with AMO's IOLs, was positively correlated with the powers of the IOLs. We also performed simulations to verify the impacts of LCA on visual performance for 4-mm pupil diameter; the simulations were a polychromatic modulation transfer function (MTF) and a visual Strehl ratio computed on the basis of an optical transfer function (VSOTF). We concluded that the differences between the LCA of different manufacturers do not affect visual performances when some extent of higher-order aberration (HOA) exists. The smaller HOA of AMO IOLs may enhance visual performance.

  7. Negative dysphotopsia: A perfect storm.

    PubMed

    Henderson, Bonnie An; Geneva, Ivayla I

    2015-10-01

    The objective of this review was to provide a summary of the peer-reviewed literature on the etiologies of negative dysphotopsia that occurs after routine cataract surgery. A search of PubMed, Google Scholar, and Retina Medical identified 59 reports. Negative dysphotopsia has been associated with many types of intraocular lenses (IOLs), including hydrophobic and hydrophilic acrylic, silicone, and 1-piece and 3-piece designs. Proposed etiologies include edge design, edge smoothness, edge thickness, index of refraction of the IOL, pupil size, amount of functional nasal retina, edema from the clear corneal incision, distance between the iris and IOL, amount of pigmentation of the eye, corneal shape, prominent globe and shallow orbit, and interaction between the anterior capsulorhexis and IOL. Treatments include a piggyback IOL, reverse optic capture, dilation of the pupil, constriction of the pupil, neodymium:YAG capsulotomy of the nasal portion of the anterior capsule, IOL exchange with round-edged optics, and time alone. This review summarizes the findings. Dr. Henderson is a consultant to Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Bausch & Lomb, and Genzyme Corp. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Is anterior chamber lens implantation after intracapsular cataract extraction safe in rural black patients in Africa? A pilot study in KwaZulu-Natal, South Africa.

    PubMed

    Cook, C D; Evans, J R; Johnson, G J

    1998-01-01

    There are an estimated 16 million people blind from cataract world-wide. In many areas the routine operation is intracapsular cataract extraction (ICCE). The role of modern anterior chamber (AC) intraocular lenses (IOLs) is being explored, and they have been shown to be safe and successful in Asia. Are they equally safe in rural black African populations? One hundred black patients aged 50 years and over who attended Edendale Hospital were enrolled in a pilot study of insertion of AC IOLs after ICCE. They were followed up for 6 months. With financial remuneration, the follow-up rate at 8 weeks increased from the usual 30% to 72%. At 6 months, 67% of eyes achieved a correlated visual acuity of 6/18 or better. Thirty per cent had persistent uveitis, 16% had peripheral anterior synechiae beyond the points of haptic contact, and 5% had an intraocular pressure greater than 21 mmHg. A randomised trial comparing ICCE with AC IOL and extracapsular cataract extraction with posterior chamber IOL is probably not justified at this time in this population. However, there may be wide variations in the reaction of the eyes of different African ethnic groups to IOLs. In view of the successful use of AC IOLs in Asian eyes, further pilot studies of AC IOLs may be warranted in other parts of Africa where ICCE is the routine procedure.

  9. Femtosecond Laser-assisted Arcuate Keratotomy Versus Toric IOL Implantation for Correcting Astigmatism.

    PubMed

    Yoo, Aeri; Yun, Samyoung; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon

    2015-09-01

    To evaluate the clinical efficacy and safety of femtosecond laser-assisted arcuate keratotomy (FS-AK) versus toric intraocular lens (IOL) implantation for correcting astigmatism in patients with cataract. A retrospective chart review was performed. All patients had senile cataracts with corneal astigmatism (range: +1.00 to +3.00 diopters [D]) before cataract surgery. Twenty-five patients agreed to undergo toric IOL implantation (the toric IOL group). Twenty-three patients did not agree to undergo toric IOL implantation despite astigmatism; however, these patients were not satisfied with their remaining astigmatism following cataract surgery and requested astigmatism correction using FS-AK (the FS-AK group). Visual acuity and intraocular pressure were evaluated, and automated refraction, keratometry, and slit-lamp examinations were performed at 1 day, 1 week, 1 month, and 5 months after surgery. Refractive astigmatism decreased in both groups. The mean preoperative and postoperative refractive cylinders were 1.71 ± 1.15 and 0.78 ± 1.06 D, respectively, in the FS-AK group (P < .001) and 1.67 ± 0.13 and 0.83 ± 0.097 D, respectively, in the toric IOL group (P < .001). There were no statistically significant differences between groups at any time during the follow-up period. FS-AK is a fast, customizable, adjustable, precise, and safe procedure for reducing refractive errors in patients with residual astigmatism after cataract surgery. The results of this procedure are comparable to the toric IOL. Copyright 2015, SLACK Incorporated.

  10. Technology and needs for tomorrow's treatment of cataract

    NASA Astrophysics Data System (ADS)

    Tassignon, Marie-José

    2007-02-01

    Cataract surgery is considered to be the most successful surgery worldwide. However, new developments are ongoing either to improve the surgical stress or to improve the surgical outcome. While restoration of the transparency and optical parameters of the eye were initially the first goals, the need to improve the quality of sight (QOS) and to restore accommodation became evident during the last decades. By introducing the bag-in-the-lens (BIL) intraocular lens (IOL) and technique of implantation (US Patent 6,027,531) in 2000, PCO was no longer a matter of concern. Clinical studies conducted between 2000 and 2004 proved the efficacy of this new IOL with respect to PCO control, but showed additional advantages like surgeon-controlled centration and rotational stability. Surgeon-controlled IOL centration based on the alignment of the first and third Purkinje reflexes is one method to promote IOL centration but future tracking devices will probably enhance the precision by which IOL centration along the line of sight can be achieved. Optimal alignment is a major issue if toric correction and compensation of the spherical aberrations is intended to be incorporated into the IOL optic. IOL optics with toric correction to compensate for regular astigmatism are in development now, but toric correction for irregular astigmatism remains extremely challenging for the manufacturers. Improving the quality of the image by compensating for the spherical aberrations is the next step on our research programme. The BIL offers some opportunities to optimize postoperative accommodation by introducing the capsular accommodation ring.

  11. Scanning electron microscopic and histologic evaluation of the AcrySof SA30AL acrylic intraocular lens. Manufacturing quality and morphology in the capsular bag.

    PubMed

    Escobar-Gomez, Marcela; Apple, David J; Vargas, Luis G; Werner, Liliana; Arthur, Stella N; Pandey, Suresh K; Izak, Andrea M; Schmidbauer, Josef M

    2003-01-01

    To evaluate the properties of the AcrySof(R) SA30AL (Alcon Laboratories, Inc.) single-piece foldable posterior chamber intraocular lens (IOL). Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. Two nonimplanted clinical-quality AcrySof IOLs were examined by gross, light, and scanning electron microscopy (SEM). In addition, 2 eyes implanted with this IOL obtained post-mortem, the first such eyes accessioned in our laboratory and the first described to date, were examined using the Miyake-Apple posterior photographic technique and by histologic sections. Scanning electron microscopy of the SA30AL IOL showed excellent surface finish. The edge of the optic was square (truncated) and had a matte (velvet or ground-glass) appearance, a feature that may minimize edge glare and other visual phenomena. A well-fabricated square or truncated optic edge was demonstrated. Miyake-Apple analysis revealed that the SA30AL IOL showed appropriate fit and configuration within the capsular bag. Histologic correlation of the IOL's square edge and its relation to the capsular bag and adjacent Soemmering's ring were noted. The AcrySof SA30AL IOL is a well-fabricated lens that situates well in the capsular bag. The truncated optic and its relationship to adjacent structures show a morphological profile that has been shown to be highly efficacious in reducing the rate of posterior capsule opacification.

  12. IOLS '98. Proceedings of the National Conference on Integrated Online Library Systems (13th, New York, New York, May 13-14, 1998).

    ERIC Educational Resources Information Center

    Cibbarelli, Pamela R., Comp.; Nixon, Carol, Comp.

    Integrated Online Library Systems (IOLS) focuses exclusively on the issues of planning and managing automated systems in libraries and information centers. The theme of the IOLS '98 annual meeting is "Embrace and Extend," and 18 papers were selected for presentation that provide insight into the current technologies being "embraced" in libraries.…

  13. In-the-Bag Intraocular Lens Placement via Secondary Capsulorhexis with Radiofrequency Diathermy in Pediatric Aphakic Eyes

    PubMed Central

    Wang, Chunxiao; Zhang, Xinyu; Tang, Xiangchen; Liu, Jianping; Congdon, Nathan; Chen, Jingjing; Lin, Zhuoling; Liu, Yizhi

    2013-01-01

    Pediatric ophthalmologists increasingly recognize that the ideal site for intraocular lens (IOL) implantation is in the bag for aphakic eyes, but it is always very difficult via conventional technique. We conducted a prospective case series study to investigate the success rate and clinical outcomes of capsular bag reestablishment and in-the-bag IOL implantation via secondary capsulorhexis with radiofrequency diathermy (RFD) in pediatric aphakic eyes, in which twenty-two consecutive aphakic pediatric patients (43 aphakic eyes) enrolled in the Childhood Cataract Program of the Chinese Ministry of Health were included. The included children underwent either our novel technique for secondary IOL implantation (with RFD) or the conventional technique (with a bent needle or forceps), depending on the type of preoperative proliferative capsular bag present. In total, secondary capsulorhexis with RFD was successfully applied in 32 eyes (32/43, 74.4%, age 5.6±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved in 30 eyes (30/43, 70.0%), but in the remaining 2 eyes (2/32, 6.2%) the IOLs were implanted in the sulcus with a capsular bag that was too small. Secondary capsulorhexis with conventional technique was applied in the other 11 eyes (11/43, 25.6%, age 6.9±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved only in 3 eyes(3/43, 7.0%), and the IOLs were implanted in the sulcus in the remaining 8 eyes. A doughnut-like proliferative capsular bag with an extensive Soemmering ring (32/43, 74.4%) was the main success factor for secondary capsulorhexis with RFD, and a sufficient capsular bag size (33/43, 76.7%) was an additional factor in successful in-the-bag IOL implantation. In conclusion, RFD secondary capsulorhexis technique has 70% success rate in the capsular bag reestablishment and in-the-bag IOL implantation in pediatric aphakic eyes, particularly effective in cases with a doughnut-like, extensively proliferative Soemmering ring. PMID:23638058

  14. Outcomes of Induction of Labour in Women with Previous Caesarean Delivery: A Retrospective Cohort Study Using a Population Database

    PubMed Central

    Stock, Sarah J.; Ferguson, Evelyn; Duffy, Andrew; Ford, Ian; Chalmers, James; Norman, Jane E.

    2013-01-01

    Background There is evidence that induction of labour (IOL) around term reduces perinatal mortality and caesarean delivery rates when compared to expectant management of pregnancy (allowing the pregnancy to continue to await spontaneous labour or definitive indication for delivery). However, it is not clear whether IOL in women with a previous caesarean section confers the same benefits. The aim of this study was to describe outcomes of IOL at 39–41 weeks in women with one previous caesarean delivery and to compare outcomes of IOL or planned caesarean delivery to those of expectant management. Methods and Findings We performed a population-based retrospective cohort study of singleton births greater than 39 weeks gestation, in women with one previous caesarean delivery, in Scotland, UK 1981–2007 (n = 46,176). Outcomes included mode of delivery, perinatal mortality, neonatal unit admission, postpartum hemorrhage and uterine rupture. 40.1% (2,969/7,401) of women who underwent IOL 39–41 weeks were ultimately delivered by caesarean. When compared to expectant management IOL was associated with lower odds of caesarean delivery (adjusted odds ratio [AOR] after IOL at 39 weeks of 0.81 [95% CI 0.71–0.91]). There was no significant effect on the odds of perinatal mortality but greater odds of neonatal unit admission (AOR after IOL at 39 weeks of 1.29 [95% CI 1.08–1.55]). In contrast, when compared with expectant management, elective repeat caesarean delivery was associated with lower perinatal mortality (AOR after planned caesarean at 39 weeks of 0.23 [95% CI 0.07–0.75]) and, depending on gestation, the same or lower neonatal unit admission (AOR after planned caesarean at 39 weeks of 0.98 [0.90–1.07] at 40 weeks of 1.08 [0.94–1.23] and at 41 weeks of 0.77 [0.60–1.00]). Conclusions A more liberal policy of IOL in women with previous caesarean delivery may reduce repeat caesarean delivery, but increases the risks of neonatal complications. PMID:23565242

  15. Types of intraocular lenses for cataract surgery in eyes with uveitis

    PubMed Central

    Leung, Theresa G; Lindsley, Kristina; Kuo, Irene C

    2014-01-01

    Background Cataract formation often occurs in people with uveitis. It is unclear which intraocular lens (IOL) type is optimal for use in cataract surgery for eyes with uveitis. Objectives To summarize the effects of different IOLs on visual acuity, other visual outcomes, and quality of life in people with uveitis. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2013), EMBASE (January 1980 to August 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to August 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 14 August 2013. We also performed forward and backward searching using the Science Citation Index and the reference lists of the included studies, respectively, in August 2013. Selection criteria We included randomized controlled trials (RCTs) comparing hydrophobic or hydrophilic acrylic, silicone, or poly(methyl methacrylate) (PMMA) IOLs with or without heparin-surface modification (HSM), with each other, or with no treatment in adults with uveitis, for any indication, undergoing cataract surgery. Data collection and analysis We used standard methodological procedures expected by The Cochrane Collaboration. Two review authors screened the search results and for included studies, assessed the risk of bias and extracted data independently. We contacted study investigators for additional information. We did not perform a meta-analysis due to variability in reporting and follow-up intervals for the primary and secondary outcomes of interest. Main results We included four RCTs involving 216 participants (range of 2 to 140 participants with uveitic cataract per trial) and comparing up to four types of IOLs. The largest study was an international study with centers in Brazil, Egypt, Finland, France, Japan, the Netherlands, Slovak Republic, Spain, and the USA; two studies were conducted in Germany and one in Saudi Arabia. There was substantial heterogeneity with respect to the ages of participants and etiologies of uveitis within and across studies. The length of follow-up among the studies ranged from 1 to 24 months after cataract surgery. The studies were at low risk of selection bias, but two of the four studies did not employ masking and only one study included all randomized participants in the final analyses. The funding source was disclosed by investigators of the largest study (professional society) and not reported by the other three. Due to heterogeneity in lens types evaluated and outcomes reported among the trials, we did not combine data in a meta-analysis. In the largest study (140 participants), the study eye of each participant was randomized to receive one of four types of IOLs: hydrophobic acrylic, silicone, HSM PMMA, or unmodified PMMA. Proportions of participants with one or more Snellen lines of visual improvement were similar among the four treatment groups at one year' follow-up: 45 of 48 (94%) in the hydrophobic acrylic IOL group, 39 of 44 (89%) in the silicone IOL group, 18 of 22 (82%) in the HSM PMMA IOL group, and 22 of 26 (85%) in the unmodified PMMA IOL group. When comparing hydrophobic acrylic IOLs with silicone IOLs, the risk ratio (RR) was 1.06 (95% confidence interval (CI) 0.93 to 1.20). At one year' follow-up, fewer eyes randomized to hydrophobic acrylic IOLs developed posterior synechiae when compared with eyes receiving silicone IOLs (RR 0.18, 95% CI 0.04 to 0.79); the effects between these groups were less certain with respect to developing posterior capsule opacification (PCO) (RR 0.74, 95% CI 0.41 to 1.37), corneal edema (RR 0.49, 95% CI 0.22 to 1.12), cystoid macular edema (RR 0.10, 95% CI 0.01 to 1.84), or mild IOL decentration (RR 0.92, 95% CI 0.06 to 14.22). Two intra-individual studies also compared HSM PMMA IOLs with unmodified PMMA IOLs at three or six months of follow-up. These studies, including a combined total of 16 participants with uveitis, were insufficiently powered to detect differences in outcomes among eyes of people with uveitis randomized to receive HSM PMMA IOLs when compared with fellow eyes receiving unmodified PMMA IOLs. In the fourth study (60 participants), the study eye of each participant was randomized to receive a hydrophobic or hydrophilic acrylic IOL. At three months, there were no statistical or clinical differences between hydrophobic and hydrophilic acrylic IOL types in the proportions of participants with two or more Snellen lines of visual improvement (RR 1.03, 95% CI 0.87 to 1.22). There were similar rates in the development of PCO between hydrophobic or hydrophilic acrylic IOLs at six months' follow-up (RR 1.00, 95% CI 0.80 to 1.25). The effect of the lenses on posterior synechiae was uncertain at six months' follow-up (RR 0.50, 95% CI 0.05 to 5.22). None of the included studies reported quality of life outcomes. Authors' conclusions Based on the trials identified in this review, there is uncertainty as to which type of IOL provides the best visual and clinical outcomes in people with uveitis undergoing cataract surgery. The studies were small, not all lens materials were compared in all studies, and not all lens materials were available in all study sites. Evidence of a superior effect of hydrophobic acrylic lenses over silicone lenses, specifically for posterior synechiae outcomes comes from a single study at a high risk of performance and detection bias. However, due to small sample sizes and heterogeneity in outcome reporting, we found insufficient information to assess these and other types of IOL materials for cataract surgery for eyes with uveitis. PMID:24590672

  16. Differences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers

    PubMed Central

    Nakajima, Masashi; Hiraoka, Takahiro; Yamamoto, Toshiya; Takagi, Seiu; Hirohara, Yoko; Oshika, Tetsuro

    2016-01-01

    Several researchers have studied the longitudinal chromatic aberration (LCA) of eyes implanted with an intraocular lens (IOL). We investigated the LCA of eyes implanted with yellow-colored IOLs from three different manufacturers: Alcon Inc., HOYA Corp., and AMO Inc. The number of subjects was 11, 16, and 16, respectively. The LCA of eyes implanted with SN60WF and SN60AT (Alcon Inc.), and with XY-1 (HOYA Corp.), was the same as that of phakic eyes. The LCA of eyes with ZCB00V (AMO Inc.) was smaller than that of phakic eyes. The LCA of eyes implanted with Alcon’s and HOYA’s IOLs, but not the LCA of eyes implanted with AMO’s IOLs, was positively correlated with the powers of the IOLs. We also performed simulations to verify the impacts of LCA on visual performance for 4-mm pupil diameter; the simulations were a polychromatic modulation transfer function (MTF) and a visual Strehl ratio computed on the basis of an optical transfer function (VSOTF). We concluded that the differences between the LCA of different manufacturers do not affect visual performances when some extent of higher-order aberration (HOA) exists. The smaller HOA of AMO IOLs may enhance visual performance. PMID:27258141

  17. Pregnancy outcome after induction of labor in women with previous cesarean section.

    PubMed

    Ashwal, Eran; Hiersch, Liran; Melamed, Nir; Ben-Zion, Maya; Brezovsky, Alex; Wiznitzer, Arnon; Yogev, Yariv

    2015-03-01

    As conflicting data exist concerning the safety of induction of labor (IoL) in women with previous single lower segment cesarean section (CS), we aimed to assess pregnancy outcome following IoL in such patient population. All singleton pregnancies with previous single CS which underwent IoL during 2008-2012 were included (study group). Their pregnancy outcome was compared to those pregnancies with previous single CS that admitted with spontaneous onset of labor (control group). Overall, 1898 pregnancies were eligible, of them, 259 underwent IoL, and 1639 were admitted with spontaneous onset of labor. Parity, gestational age at delivery and birthweight were similar. Women in the study group were more likely to undergo CS mainly due to labor dystocia (8.1 versus 3.7%, p < 0.01). The rate of CS due to non-reassuring fetal heart rate was similar. No difference was found in the rate of uterine rupture/dehiscence. Short-term neonatal outcome was similar between the groups. On multivariable logistic regression analysis, IoL was not independently associated with uterine rupture (OR 1.33, 95% C.I 0.46-3.84, p = 0.59). Our data suggest that IoL in women with one previous low segment CS neither increases the risk of uterine rupture nor adversely affects immediate neonatal outcome.

  18. Ultra-widefield retinal imaging through a black intraocular lens.

    PubMed

    Yusuf, Imran H; Fung, Timothy H M; Patel, Chetan K

    2015-09-01

    To evaluate the feasibility of ultra-widefield retinal imaging in patients with near infrared (IR)-transmitting black intraocular lenses (IOLs). Oxford Eye Hospital, Oxford, United Kingdom. Laboratory evaluation of a diagnostic technology with interventional case report. The field of retinal imaging through a Morcher poly(methyl methacrylate) (PMMA) black IOL was determined in a purpose-built adult schematic model eye with the HRA2 Spectralis confocal scanning laser ophthalmoscope using standard imaging, Staurenghi retina lens-assisted imaging, and ultra-widefield noncontact imaging. Retinal imaging using each modality was then performed on a patient implanted with another Morcher PMMA black IOL model. Ultra-widefield noncontact imaging and lens-assisted imaging captured up to 150 degrees of field (versus 40 degrees with a standard confocal scanning laser ophthalmoscope). Ultra-widefield retinal images were successfully acquired in a patient eye with a black IOL. This study has identified the first ultra-widefield retinal imaging modalities for patients with near IR-transmitting black IOLs. Should larger studies confirm this finding, noncontact ultra-widefield confocal scanning laser ophthalmoscopy might be considered the gold standard imaging technique for retinal surveillance in patients with near IR-transmitting black IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling

    NASA Astrophysics Data System (ADS)

    Remón, Laura; Siedlecki, Damian; Cabeza-Gil, Iulen; Calvo, Begoña

    2018-03-01

    Intraocular lenses (IOLs) are used in the cataract treatment for surgical replacement of the opacified crystalline lens. Before being implanted they have to pass the strict quality control to guarantee a good biomechanical stability inside the capsular bag, avoiding the rotation, and to provide a good optical quality. The goal of this study was to investigate the influence of the material and haptic design on the behavior of the IOLs under dynamic compression condition. For this purpose, the strain-stress characteristics of the hydrophobic and hydrophilic materials were estimated experimentally. Next, these data were used as the input for a finite-element model (FEM) to analyze the stability of different IOL haptic designs, according to the procedure described by the ISO standards. Finally, the simulations of the effect of IOL tilt and decentration on the optical performance were performed in an eye model using a ray-tracing software. The results suggest the major importance of the haptic design rather than the material on the postoperative behavior of an IOL. FEM appears to be a powerful tool for numerical studies of the biomechanical properties of IOLs and it allows one to help in the design phase to the manufacturers.

  20. Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling.

    PubMed

    Remón, Laura; Siedlecki, Damian; Cabeza-Gil, Iulen; Calvo, Begoña

    2018-03-01

    Intraocular lenses (IOLs) are used in the cataract treatment for surgical replacement of the opacified crystalline lens. Before being implanted they have to pass the strict quality control to guarantee a good biomechanical stability inside the capsular bag, avoiding the rotation, and to provide a good optical quality. The goal of this study was to investigate the influence of the material and haptic design on the behavior of the IOLs under dynamic compression condition. For this purpose, the strain-stress characteristics of the hydrophobic and hydrophilic materials were estimated experimentally. Next, these data were used as the input for a finite-element model (FEM) to analyze the stability of different IOL haptic designs, according to the procedure described by the ISO standards. Finally, the simulations of the effect of IOL tilt and decentration on the optical performance were performed in an eye model using a ray-tracing software. The results suggest the major importance of the haptic design rather than the material on the postoperative behavior of an IOL. FEM appears to be a powerful tool for numerical studies of the biomechanical properties of IOLs and it allows one to help in the design phase to the manufacturers. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  1. In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model.

    PubMed

    Tandogan, Tamer; Auffarth, Gerd U; Choi, Chul Y; Liebing, Stephanie; Mayer, Christian; Khoramnia, Ramin

    2017-02-08

    To analyse objective optical properties of the spherical and aspheric design of the same intraocular lens (IOL) model using optical bench analysis. This study entailed a comparative analysis of 10 spherical C-flex 570 C and 10 aspheric C-flex 970 C IOLs (Rayner Intraocular Lenses Ltd., Hove, UK) of 26 diopters [D] using an optical bench (OptiSpheric, Trioptics, Germany). In all lenses, we evaluated the modulation transfer function (MTF) at 50 lp/mm and 100 lp/mm and the Strehl Ratio using a 3-mm (photopic) and 4.5-mm (mesopic) aperture. At 50 lp/mm, the MTF values were 0.713/0.805 (C-flex 570 C/C-flex 970 C) for a 3-mm aperture and 0.294/0.591 for a 4.5-mm aperture. At 100 lp/mm, the MTF values were 0.524/0.634 for a 3-mm aperture and 0.198/0.344 for a 4.5-mm aperture. The Strehl Ratio was 0.806/0.925 and 0.237/0.479 for a 3-mm and 4.5-mm aperture respectively. A Mann-Whitney U test revealed all intergroup differences to be statistically significant (p < 0.01). The aspheric IOL design achieved higher MTF values than the spherical design of the same IOL for both apertures. Moreover, the differences between the two designs of the IOL were more prominent for larger apertures. This suggests that the evaluated IOL provides enhanced optical quality to patients with larger pupils or working under mesopic conditions.

  2. [Quantitative evaluation of acrylic and silicone intraocular lenses with a sharp optic edge design].

    PubMed

    Rabsilber, T M; Reuland, A J; Entz, B B; Holzer, M P; Limberger, I J; Auffarth, G U

    2006-01-01

    At the Department of Ophthalmology, Heidelberg, Germany, posterior capsule opacification (PCO) of a silicone and an acrylic intraocular lens (IOL) with a sharp optic edge design was evaluated. In a prospective study either the AMO ClariFlex silicone IOL or the Sensar AR40e hydrophobic acrylic IOL were implanted in 47 patients following uneventful phacoemulsification. Mean patient age was 76.2+/-7.8 (ClariFlex) and 73.4+/-12.9 years (AR40e), respectively. The mean follow-up time was 19.7+/-5.34 in the ClariFlex and 21.9+/-1.89 months in the AR40e group. PCO development was evaluated postoperatively using the EPCO 2000 analysis software (scale 0-4). Areas of interest were the total IOL optic, the central 3-mm zone as well as the capsulorhexis. In both groups, all patients achieved a BCVA of 20/32 (AR40e) and 20/25 (ClariFlex), respectively. There was a very low incidence of PCO development with a mean EPCO score of 0.07+/-0.2 (ClariFlex and 0.15+/-0.2 (AR40e). Within the 3-mm zone and the capsulorhexis, there was a tendency for even lower EPCO scores in both groups. We calculated a statistically significant difference for the two lens materials for all investigated IOL areas (Wilcoxon's test, p<0.05). Both IOLs with a sharp edge design showed good functional results, a stable position in the capsular bag as well as a low incidence of PCO development. However, the silicone IOL showed statistically significantly lower PCO scores.

  3. Optimized constants for an ultraviolet light-adjustable intraocular lens.

    PubMed

    Conrad-Hengerer, Ina; Dick, H Burkhard; Hütz, Werner W; Haigis, Wolfgang; Hengerer, Fritz H

    2011-12-01

    To determine the accuracy of intraocular lens (IOL) power calculations and to suggest adjusted constants for implantation of ultraviolet light-adjustable IOLs. Center for Vision Science, Ruhr University Eye Clinic, Bochum, Germany. Cohort study. Eyes with a visually significant cataract that had phacoemulsification with implantation of a light-adjustable IOL were evaluated. IOLMaster measurements were performed before phacoemulsification and IOL implantation and 4 weeks after surgery before the first adjustment of the IOL. The difference in the expected refraction and estimation error was studied. The study evaluated 125 eyes. Using the surgical constants provided by the manufacturer of the light-adjustable IOL, the SRK/T formula gave a more hyperopic refraction than the Hoffer Q and Holladay 1 formulas. The mean error of prediction was 0.93 diopter (D) ± 0.69 (SD), 0.91 ± 0.63 D, and 0.86 ± 0.65 D, respectively. The corresponding mean absolute error of prediction was 0.98 ± 0.61 D, 0.93 ± 0.61 D, and 0.90 ± 0.59 D, respectively. With optimized constants for the formulas, the mean error of prediction was 0.00 ± 0.63 D for Hoffer Q, 0.00 ± 0.64 D for Holladay 1, and 0.00 ± 0.66 D for SRK/T. The expected refraction after phacoemulsification and implantation of a light-adjustable IOL toward the hyperopic side of the desired refraction could be considered when using the optimized constants for all formulas. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    PubMed

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  5. Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study

    PubMed Central

    Bala, Chandra; Shi, Jeffrey; Meades, Kerrie

    2015-01-01

    Purpose: To transect intraocular lenses (IOLs) using a femtosecond laser in cadaveric human eyes. To determine the optimal in vitro settings, to detect and characterize gasses or particles generated during this process. Methods: A femtosecond laser was used to transect hydrophobic and hydrophilic acrylic lenses. The settings required to enable easy separation of the lens fragment were determined. The gasses and particles generated were analysed using gas chromatography mass spectrometer (GC-MS) and total organic carbon analyzer (TOC), respectively. Results: In vitro the IOL fragments easily separated at the lowest commercially available energy setting of 1 μJ, 8-μm spot, and 2-μm line separation. No particles were detected in the 0.5- to 900-μm range. No significant gasses or other organic breakdown by products were detected at this setting. At much higher energy levels 12 μJ (4 × 6 μm spot and line separation) significant pyrolytic products were detected, which could be harmful to the eye. In cadaveric explanted IOL capsule complex the laser pulses could be applied through the capsule to the IOL and successfully fragment the IOL. Conclusion: IOL transection is feasible with femtosecond lasers. Further in vivo animal studies are required to confirm safety. Translational Relevance: In clinical practice there are a number of large intraocular lenses that can be difficult to explant. This in-vitro study examines the possibility of transecting the lasers quickly using femtosecond lasers. If in-vivo studies are successful, then this innovation could help ophthalmic surgeons in IOL explantation. PMID:26101721

  6. Minimizing the IOL power error induced by keratometric power.

    PubMed

    Camps, Vicente J; Piñero, David P; de Fez, Dolores; Mateo, Verónica

    2013-07-01

    To evaluate theoretically in normal eyes the influence on IOL power (PIOL) calculation of the use of a keratometric index (nk) and to analyze and validate preliminarily the use of an adjusted keratometric index (nkadj) in the IOL power calculation (PIOLadj). A model of variable keratometric index (nkadj) for corneal power calculation (Pc) was used for IOL power calculation (named PIOLadj). Theoretical differences (ΔPIOL) between the new proposed formula (PIOLadj) and which is obtained through Gaussian optics ((Equation is included in full-text article.)) were determined using Gullstrand and Le Grand eye models. The proposed new formula for IOL power calculation (PIOLadj) was prevalidated clinically in 81 eyes of 81 candidates for corneal refractive surgery and compared with Haigis, HofferQ, Holladay, and SRK/T formulas. A theoretical PIOL underestimation greater than 0.5 diopters was present in most of the cases when nk = 1.3375 was used. If nkadj was used for Pc calculation, a maximal calculated error in ΔPIOL of ±0.5 diopters at corneal vertex in most cases was observed independently from the eye model, r1c, and the desired postoperative refraction. The use of nkadj in IOL power calculation (PIOLadj) could be valid with effective lens position optimization nondependent of the corneal power. The use of a single value of nk for Pc calculation can lead to significant errors in PIOL calculation that may explain some IOL power overestimations with conventional formulas. These inaccuracies can be minimized by using the new PIOLadj based on the algorithm of nkadj.

  7. Capture of intraocular lens optic by residual capsular opening in secondary implantation: long-term follow-up.

    PubMed

    Tian, Tian; Chen, Chunli; Jin, Haiying; Jiao, Lyu; Zhang, Qi; Zhao, Peiquan

    2018-04-02

    To introduce a novel surgical technique for optic capture by residual capsular opening in secondary intraocular lens (IOL) implantation and to report the outcomes of a long follow-up. Twenty patients (20 eyes) who had received secondary IOL implantation with the optic capture technique were retrospectively reviewed. We used the residual capsular opening for capturing the optic and inserted the haptics in the sulcus during surgery. Baseline clinical characteristics and surgical outcomes, including best-corrected visual acuity (BCVA), refractive status, and IOL position were recorded. The postoperative location and stability of IOL were evaluated using the ultrasound biomicroscopy. Optic capture technique was successfully performed in all cases, including 5 cases with large area of posterior capsular opacity, 6 cases with posterior capsular tear or rupture,and 9 cases with adhesive capsules. BCVA improved from 0.60 logMAR at baseline to 0.36 logMAR at the last follow-up (P < 0.001). Spherical equivalent changed from 10.67 ± 4.59 D at baseline to 0.12 ± 1.35 D at 6 months postoperatively (P < 0.001). Centered IOLs were observed in all cases and remained captured through residual capsular opening in 19 (95%) eyes at the last follow-up. In one case, the captured optic of IOL slid into ciliary sulcus at 7 months postoperatively. No other postoperative complications were observed in any cases. This optic capture technique by using residual capsule opening is an efficacious and safe technique and can achieve IOL stability in the long follow-up.

  8. Influence of a new surface modification of intraocular lenses with fluoroalkylsilan on the adherence of endophthalmitis-causing bacteria in vitro.

    PubMed

    Kienast, Antonia; Kämmerer, Regine; Weiss, Claudia; Klinger, Matthias; Menz, Dirk-Henning; Dresp, Joachim; Ohgke, Helge; Solbach, Werner; Laqua, Horst; Hoerauf, Hans

    2006-09-01

    Dynasilan is a fluoroalkylsilan that is able to interact with surface active centres on intraocular lenses (IOL), offering a new way for surface modification of different IOL materials. The purpose of this in vitro study was to investigate the influence of this new surface modification on the adherence of two typical endophthalmitis causing bacteria (Staphylococcus epidermidis, Propionibacterium acnes). In a pilot experiment, the effect of Dynasilan coating on the adherence of S. epidermidis was tested on glass slides. Forty-two Dynasilan-modified and 42 unmodified IOL (14 PMMA, 14 silicone and 14 hydrogel) were incubated at 37 degrees C in brain heart infusion broth (10(8) CFU/ml) with either S. epidermidis for 24 h or with P. acnes for 1 h. Subsequently, the adherent bacteria were resuspended using ultrasonification at 35 kHz for 3x45 s. After dilution series and incubation at 37 degrees C on Petri dishes for 24 h and 3 days, respectively, the colonies were counted. In the pilot experiment, a markedly lower number of adherent S. epidermidis was observed on Dynasilan-modified glass slides. Of all IOL materials incubated with S. epidermidis, those modified with Dynasilan showed a lower mean number of adherent bacteria (mean 1.37x10(7); SD 2.37x10(7)) than those untreated (2.43x10(7); SD 3.04x10(7)). IOLs incubated with P. acnes showed a significantly lower mean number of adherent bacteria of 2.51x10(4) (SD 2.71x10(4)) on Dynasilan-modified IOLs versus 6.27x10(4) (SD 7.70x10(4)) on untreated IOLs. The presented in vitro results indicate that Dynasilan surface modification is able to reduce the adherence of S. epidermidis and P. acnes on all IOL materials tested. Further studies regarding the stability of this modification and its biocompatibility must be performed.

  9. Microincision Hydrophobic Acrylic Aspheric Toric Intraocular Lens for Astigmatism and Cataract Correction.

    PubMed

    Bissen-Miyajima, Hiroko; Negishi, Kazuno; Hieda, Osamu; Kinoshita, Shigeru

    2015-06-01

    To evaluate the efficacy and safety of a new acrylic one-piece toric intraocular lens (IOL). This prospective multicenter clinical trial included 93 eyes of 61 patients that were implanted with a hydrophobic acrylic toric IOL from 2010 to 2012 and followed for 1 year. This IOL uses the platform of a microincision one-piece aspheric IOL, the NY-60 IOL (HOYA, Tokyo, Japan), with three increments in cylindrical power (NHT15, 1.5 diopters [D]; NHT23, 2.25 D; and NHT30, 3.0 D). The inclusion criterion was preoperative corneal astigmatism from 0.75 to 3.00 D. The primary endpoint was uncorrected distance visual acuity (UDVA) of 0.0 logMAR (20/20 Snellen) or better 6 months postoperatively. In addition to UDVA, corrected distance visual acuity (CDVA), residual astigmatism, stability of the IOL alignment, need of realignment, and the rate of Nd:YAG laser capsulotomy were evaluated up to 1 year postoperatively. Errors in astigmatic correction were assessed using Alpin's vector analysis. The primary endpoint was achieved in 54.8% of eyes. One year postoperatively, the logMAR UDVAs were 0.02 ± 0.13, 0.05 ± 0.17, and 0.09 ± 0.14 with models NHT15, NHT23, and NHT30, which corresponds to 0.96 (19/20 Snellen), 0.89 (18/20 Snellen), and 0.82 (16/20 Snellen), respectively. One year postoperatively, the residual astigmatism was 0.66 ± 0.58 D. In each evaluation, the mean absolute change in the position of the axis mark was between 1.93° and 2.32°. Three eyes required repositioning of the IOL axis and 2 eyes received Nd:YAG laser capsulotomy. The correction error showed an undercorrection with against-the-rule astigmatism and overcorrection with with-the-rule astigmatism. The new one-piece toric IOL provided desirable clinical outcomes and stability in eyes with corneal astigmatism. Copyright 2015, SLACK Incorporated.

  10. Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series.

    PubMed

    Hawlina, Gregor; Perovšek, Darko; Drnovšek-Olup, Brigita; MoŽina, Janez; Gregorčič, Peter

    2014-11-18

    Posterior capsule opacification (PCO) is the most common post-operative complication associated with cataract surgery and is mostly treated with Nd:YAG laser capsulotomy. Here, we demonstrate the use of high-resolution spectral-domain optical coherence tomography (OCT) as a technique for PCO analysis. Additionally, we evaluate the influence of PCO types and the distance between the intraocular lens (IOL) and the posterior capsule (PC), i.e., the IOL/PC distance, on the total-pulse energy required for the Nd:YAG laser posterior capsulotomy. 47 eyes with PCO scheduled for the Nd:YAG procedure were examined and divided into four categories: fibrosis, pearl, mixed type and late-postoperative capsular bag distension syndrome. Using custom-made computer software for OCT image analysis, the IOL/PC distances in two dimensions were measured. The IOL/PC distances were compared with those of a control group of 15 eyes without PCO. The influence of the different PCO types and the IOL/PC distance on the total-pulse energy required for the Nd:YAG procedure was analyzed. The total-pulse energy required for a laser capsulotomy differs significantly between PCO types (p = 0.005, Kruskal-Wallis test). The highest energy was required for the fibrosis PCO type, followed by mixed, pearl and late-postoperative capsular bag distension syndrome. The IOL/PC distance also significantly influenced the total-pulse energy required for laser capsulotomy (p = 0.028, linear regression). Lower total-pulse energy was expected for a larger IOL/PC distance. Our study indicates that the PCO types and the IOL/PC distance influence the total-pulse energy required for Nd:YAG capsulotomy. The presented OCT method has the potential to become an additional tool for PCO characterization. Our results are important for a better understanding of the photodisruptive mechanisms in Nd:YAG capsulotomy.

  11. Bilateral reading performance of 4 multifocal intraocular lens models and a monofocal intraocular lens under bright lighting conditions.

    PubMed

    Rasp, Max; Bachernegg, Alexander; Seyeddain, Orang; Ruckhofer, Josef; Emesz, Martin; Stoiber, Josef; Grabner, Günther; Dexl, Alois K

    2012-11-01

    To compare changes in reading performance parameters after implantation of 4 multifocal intraocular lens (IOL) models and a monofocal IOL. Department of Ophthalmology, Paracelsus Medical University, Salzburg, Austria. Prospective randomized controlled clinical trial. Patients with bilateral cataract without additional ocular pathology were scheduled for bilateral implantation of Acri.Smart 48S monofocal, Acrysof Restor SN6AD3 apodized multifocal, AT LISA 366D diffractive multifocal, Tecnis ZMA00 diffractive multifocal, or Rezoom refractive multifocal IOLs. Bilateral corrected and uncorrected reading acuity, reading distance, mean and maximum reading speeds, and smallest log-scaled print size of a Radner reading chart were evaluated under bright lighting conditions (500 lux) using the Salzburg Reading Desk. Pupil size was not measured throughout the trial. The minimum follow-up was 12 months. The diffractive multifocal groups had significantly better uncorrected reading acuity and uncorrected smallest print size than the monofocal and refractive multifocal groups 1, 6, and 12 months postoperatively. The diffractive IOL groups had comparable uncorrected reading distance of approximately 32 cm, which was larger in the monofocal group (38.9 ± 8.4 cm) and refractive multifocal group (37.1 ± 7.3 cm) at the last visit. Patients with diffractive IOLs could read print sizes of approximately 0.74 to 0.87 mm, which was much better than in the monofocal and refractive multifocal groups. The diffractive AT LISA IOL provided the best reading speed values (mean and maximum, corrected and uncorrected). Multifocal IOLs with a diffractive component provided good reading performance that was significantly better than that obtained with a refractive multifocal or monofocal IOL. Drs. Grabner and Dexl were patent owners of the Salzburg Reading Desk technology (now owned by SRD-Vision, LLC). No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Spectral properties of common intraocular lens (IOL) types

    NASA Astrophysics Data System (ADS)

    Milne, Peter J.; Chapon, Pascal F.; Hamaoui, Marie; Parel, Jean-Marie A.; Clayman, H.; Rol, Pascal O.

    1999-06-01

    Currently over 50 kinds of intraocular lenses (IOLs) are approved for patient use in the treatment of cataracts and ametropia. These lenses are manufactured from at least 2 kinds of silicones as well as several kinds of acrylic polymers including polyHEMA, Poly HOXEMA, a range of polymethacrylate and polyacrylate formulations. We sought to measure spectral transmission curves of a range of IOLS in the UV-visible and near IR spectral regions in order to better characterize their optical properties and to provide a baseline from which to assess their alteration following implantation over time. Consideration of how this may best be achieved are discussed. The variable ability of both explained IOLs and some samples from a range of manufacturers to block UV wavelengths is commented upon.

  13. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500).

    PubMed

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je

    2017-03-01

    To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.

  14. Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500)

    PubMed Central

    Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun

    2017-01-01

    Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576

  15. HFE gene mutation and oxidative damage biomarkers in patients with myelodysplastic syndromes and its relation to transfusional iron overload: an observational cross-sectional study.

    PubMed

    De Souza, Geane Felix; Ribeiro, Howard Lopes; De Sousa, Juliana Cordeiro; Heredia, Fabíola Fernandes; De Freitas, Rivelilson Mendes; Martins, Manoel Ricardo Alves; Gonçalves, Romélia Pinheiro; Pinheiro, Ronald Feitosa; Magalhães, Silvia Maria Meira

    2015-04-03

    A relation between transfusional IOL (iron overload), HFE status and oxidative damage was evaluated. An observational cross-sectional study involving 87 healthy individuals and 78 patients with myelodysplastic syndromes (MDS) with and without IOL, seen at University Hospital of the Federal University of Ceará, Brazil, between May 2010 and September 2011. IOL was defined using repeated measures of serum ferritin ≥1000 ng/mL. Variations in the HFE gene were investigated using PCR/restriction fragment length polymorphism (RFLP). The biomarkers of oxidative stress (plasmatic malonaldehyde (MDA), glutathione peroxidase (GPx) and superoxide dismutase (SOD)) were determined by spectrophotometry. The HFE gene variations were identified in 24 patients (30.77%) and 5 volunteers (5.74%). The H63D variant was observed in 35% and the C282Y variant as heterozygous in 5% of patients with MDS with IOL. One patient showed double heterozygous variant (C282Y/H63D) and serum ferritin of 11,649 ng/mL. In patients without IOL, the H63D variant was detected in 29.34%. Serum MDA levels were highest in patients with MDS with IOL, with a significant difference when compared with patients without IOL and healthy volunteers, pointing to the relationship between IOL and oxidative stress. The GPx and SOD were also significantly higher in these patients, indicating that lipid peroxidation increase was followed by an increase in antioxidant capacity. Higher ferritin levels were observed in patients with HFE gene variation. 95.7% of patients with MDS with the presence of HFE gene variations had received more of 20 transfusions. We observed a significant increase in MDA levels in patients with MDS and IOL, suggesting an increased lipid peroxidation in these patients. The accumulation of MDA alters the organisation of membrane phospholipids, contributing to the process of cellular degeneration. Results show that excess iron intensifies the process of cell damage through oxidative stress. Local Ethics Committee (licence 150/2009). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Aberration-free intraocular lenses - What does this really mean?

    PubMed

    Langenbucher, Achim; Schröder, Simon; Cayless, Alan; Eppig, Timo

    2017-09-01

    So-called aberration-free intraocular lenses (IOLs) are well established in modern cataract surgery. Usually, they are designed to perfectly refract a collimated light beam onto the focal point. We show how much aberration can be expected with such an IOL in a convergent light beam such as that found anterior to the human cornea. Additionally, the aberration in a collimated beam is estimated for an IOL that has no aberrations in the convergent beam. The convergent beam is modelled as the pencil of rays corresponding to the spherical wavefront resulting from a typical corneal power of 43m -1 . The IOLs are modelled as infinitely thin phase plates with 20m -1 optical power placed 5mm behind the cornea. Their aberrations are reported in terms of optical path length difference and longitudinal spherical aberration (LSA) of the marginal rays, as well as nominal spherical aberration (SA) calculated based on a Zernike representation of the wavefront-error at the corneal plane within a 6mm aperture. The IOL designed to have no aberrations in a collimated light beam has an optical path length difference of -1.8μm, and LSA of 0.15m -1 in the convergent beam of a typical eye. The corresponding nominal SA is 0.065μm. The IOL designed to have no aberrations in a convergent light beam has an optical path length difference of 1.8μm, and LSA of -0.15m -1 in the collimated beam. An IOL designed to have no aberrations in a collimated light beam will increase the SA of a patient's eye after implantation. Copyright © 2017. Published by Elsevier GmbH.

  17. Energy Efficiency of a New Trifocal Intraocular Lens

    NASA Astrophysics Data System (ADS)

    Vega, F.; Alba-Bueno, F.; Millán, M. S.

    2014-01-01

    The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.

  18. Refractive accuracy with light-adjustable intraocular lenses.

    PubMed

    Villegas, Eloy A; Alcon, Encarna; Rubio, Elena; Marín, José M; Artal, Pablo

    2014-07-01

    To evaluate efficacy, predictability, and stability of refractive treatments using light-adjustable intraocular lenses (IOLs). University Hospital Virgen de la Arrixaca, Murcia, Spain. Prospective nonrandomized clinical trial. Eyes with a light-adjustable IOL (LAL) were treated with spatial intensity profiles to correct refractive errors. The effective changes in refraction in the light-adjustable IOL after every treatment were estimated by subtracting those in the whole eye and the cornea, which were measured with a Hartmann-Shack sensor and a corneal topographer, respectively. The refractive changes in the whole eye and light-adjustable IOL, manifest refraction, and visual acuity were obtained after every light treatment and at the 3-, 6-, and 12-month follow-ups. The study enrolled 53 eyes (49 patients). Each tested light spatial pattern (5 spherical; 3 astigmatic) produced a different refractive change (P<.01). The combination of 2 light adjustments induced a maximum change in spherical power of the light-adjustable IOL of between -1.98 diopters (D) and +2.30 D and in astigmatism of up to -2.68 D with axis errors below 9 degrees. Intersubject variability (standard deviation) ranged between 0.10 D and 0.40 D. The 2 required lock-in procedures induced a small myopic shift (range +0.01 to +0.57 D) that depended on previous adjustments. Light-adjustable IOL implantation achieved accurate refractive outcomes (around emmetropia) with good uncorrected distance visual acuity, which remained stable over time. Further refinements in nomograms and in the treatment's protocol would improve the predictability of refractive and visual outcomes with these IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Micropatterned Protective Membranes Inhibit Lens Epithelial Cell Migration in Posterior Capsule Opacification Model

    PubMed Central

    Magin, Chelsea M.; May, Rhea M.; Drinker, Michael C.; Cuevas, Kevin H.; Brennan, Anthony B.; Reddy, Shravanthi T.

    2015-01-01

    Purpose To evaluate the ability of Sharklet (SK) micropatterns to inhibit lens epithelial cell (LEC) migration. Sharklet Technologies, Inc. (STI) and InSight Innovations, LLC have proposed to develop a Sharklet-patterned protective membrane (PM) to be implanted in combination with a posterior chamber intraocular lens (IOL) to inhibit cellular migration across the posterior capsule, and thereby reduce rates of posterior capsular opacification (PCO). Methods A variety of STI micropatterns were evaluated versus smooth (SM) controls in a modified scratch wound assay for the ability to reduce or inhibit LEC migration. The best performing topography was selected, translated to a radial design, and applied to PM prototypes. The PM prototypes were tested in an in vitro PCO model for reduction of cell migration behind an IOL versus unpatterned prototypes and IOLs with no PM. In both assays, cell migration was analyzed with fluorescent microscopy. Results All SK micropatterns significantly reduced LEC migration compared with SM controls. Micropatterns that protruded from the surface reduced migration more than recessed features. The best performing micropattern reduced LEC coverage by 80%, P = 0.0001 (ANOVA, Tukey Test). Micropatterned PMs reduced LEC migration in a PCO model by 50%, P = 0.0005 (ANOVA, Tukey Test) compared with both IOLs with no PM and IOLs with SM PMs. Conclusions Collectively, in vitro results indicate the implantation of micropatterned PMs in combination with posterior chamber IOLs could significantly reduce rates of clinically relevant PCO. This innovative technology is a globally accessible solution to high PCO rates. Translational Relevance A novel IOL incorporating the SK micropattern in a membrane design surrounding the optic may help increase the success of cataract surgery by reducing secondary cataract, or PCO. PMID:25883876

  20. Spectral transmittance of intraocular lenses under natural and artificial illumination: criteria analysis for choosing a suitable filter.

    PubMed

    Artigas, Jose M; Felipe, Adelina; Navea, Amparo; Artigas, Cristina; García-Domene, Maria C

    2011-01-01

    To compare the spectral transmission of different intraocular lenses (IOLs) with either ultraviolet (UV) or blue-light filters, and to analyze the performance of these filters with artificial light sources as well as sunlight. Experimental study. The spectral transmission curve of 10 IOLs was measured using a PerkinElmer Lambda 800 UV/VIS spectrometer (Waltham, MA). Different filtering simulations were performed using the D65 standard illuminant as daylight and standard incandescent lamp and fluorescent bulb illuminants. Spectral transmittance of the IOLs. All the IOLs studied provide good UVC (200-280 nm) and UVB (280-315 nm) protection, except for one that presented an appreciable window at 270 nm. Nevertheless, both natural and artificial sources have practically no emission under 300 nm. In the UVA (315-380 nm) range the curves of the different IOLs manifested different degrees of absorption. Not all the UV filters incorporated in different IOLs protect equally. The filters that provide greater photoprotection against UV radiation, even blue light, are yellow and orange. Then, yellow and orange IOL filters may be best suited for cases requiring special retinal protection. The filters that favor better photoreception of visible light (380-780 nm) are those that transmit this radiation close to 100%. Artificial illumination practically does not emit in the UV range, but its levels of illumination are very low when compared with solar light. A possible balance between photoprotection and photoreception could be a sharp cutoff filter with the cutoff wavelength near 400 nm and a maximum transmittance around 100%. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  1. Influence on Visual Quality of Intraoperative Orientation of Asymmetric Intraocular Lenses.

    PubMed

    Bonaque-González, Sergio; Ríos, Susana; Amigó, Alfredo; López-Gil, Norberto

    2015-10-01

    To evaluate visual quality when changing the intraocular orientation of the Lentis Mplus LS-312MF nonrotational symmetric +3.00 diopters aspheric multifocal intraocular lens ([IOL] Oculentis GmbH, Berlin, Germany) in normal eyes. An artificial eye was used to measure the in vitro wavefront of the IOL. The corneal topography of 20 healthy patients was obtained. For each eye, a computational analysis simulated the implantation of the IOL. The modulation transfer function (MTF) and an image quality parameter (visually modulated transfer function [VSMTF] metric) were calculated for a 5.0-mm pupil and for three conditions: distance, intermediate, and near vision. The procedure was repeated for each eye after a rotation of the IOL with respect to the cornea from 0° to 360° in 1° steps. Statistical analysis showed significant differences in mean VSMTF values between orientations for distance vision. Optimal orientation of the IOL (different for each eye) showed a mean improvement of 58% ± 19% (range: 20% to 121%) in VSMTF values with respect to the worst possible orientation. For these orientations, intermediate and near vision quality were statistically indistinguishable. The MTFs were different between orientations, showing a mean difference of approximately 5 cycles per degree in the maximum spatial frequencies that can be transferred between the best and the worst orientations for distance vision. The results suggest that implantation of this nonrotational symmetric IOL should improve visual outcomes if it is oriented to coincide with a customized meridian. A simple, practical method is proposed to find an approximation to the angle that an Mplus IOL should be inserted. Copyright 2015, SLACK Incorporated.

  2. Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation.

    PubMed

    Forlini, Cesare; Forlini, Matteo; Rejdak, Robert; Prokopiuk, Agata; Levkina, Oxana; Bratu, Adriana; Rossini, Paolo; Cagampang, Perfecto R; Cavallini, Gian Maria

    2013-03-01

    Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia. Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel. Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque. Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.

  3. Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomes.

    PubMed

    Nuijts, Rudy M M A; Jonker, Soraya M R; Kaufer, Robert A; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas

    2016-02-01

    To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8 investigative sites. Prospective randomized parallel-group patient-masked 2-arm study. This study comprised adults requiring bilateral cataract extraction followed by multifocal IOL implantation. The primary endpoint was corrected intermediate visual acuity (CIVA) at 60 cm, and the secondary endpoint was corrected near visual acuity (CNVA) at 40 cm. Both endpoints were measured 3 months after implantation with a noninferiority margin of Δ = 0.1 logMAR. In total, 103 patients completed the study (53 bilateral, 50 contralateral). At 3 months, the mean CIVA at 60 cm was 0.13 logMAR and 0.10 logMAR in the bilateral group and contralateral group, respectively (difference 0.04 logMAR), achieving noninferiority. Noninferiority was not attained for CNVA at 40 cm; mean values at 3 months for bilateral and contralateral implantation were 0.26 logMAR and 0.11 logMAR, respectively (difference 0.15 logMAR). Binocular defocus curves suggested similar performance in distance vision between the 2 groups. Treatment-emergent ocular adverse events rates were similar between the groups. Bilateral implantation of the +2.5 D multifocal IOL resulted in similar distance as contralateral implantation of the +2.5 D multifocal IOL and +3.0 D multifocal IOL for intermediate vision (60 cm), while noninferiority was not achieved for near distances (40 cm). Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. [Fabrication and Performance Study of Polydimethylsiloxane Intraocular Lens].

    PubMed

    Du, Qiuyue; Yu, Yueqing

    2016-10-01

    To simplify the production process of intraocular lens(IOL)and to solve the problem of lacking adjustable ability,we proposed a novel soft IOL with large-scale adjustable ability and rigid haptics based on heat-assisted method,and gravity-assisted method.Polydimethylsiloxane(PDMS)and rigid material--polymethyl methacrylate(PMMA)were used as the materials for fabricating optical lens(PDMS)and haptics(PDMS and PMMA)through changing the weight ratio of the solution.A lens-smartphone microscopy system was established to replace the traditional digital microscopy to measure the tiny displacements and shape changes.The PDMS lens has excellent optical property through an experiment in which the maximum optical power was around 273.2D.Experimental results indicated that the maximum optical power of PMMA IOL was 129.3D,and that in PDMS IOL,however,was only 56.0D.Thus,the rigid PMMA-IOL has a larger adjustable range.The production process of PDMS was mold-free,rapid,real-time,and highly repeatable and there was no need for a rigorous experimental environment either.This creative processing technology reduced the manufacturing steps from which an optical lens with high transmittance and high resolution,as well as hatics with accurate dimensions,were obtained.The rigidity of haptics affected more intensely than other factors did for improving the pre-displacement and changing the appearance of PDMS lens.Even though the rigidity of PMMA haptics is large enough for accommodating,there are many drawbacks during manufacturing.It is unavailable to rapid fabricate IOL using PMMA.Thus,further work will be required to alter the weight ratio of PDMS material,increase the rigidity,and enhance the adjustable ability of PDMS IOL.

  5. Preventive induction of labor for non-urgent indications at term and maternal and neonatal outcomes.

    PubMed

    Zhang, Lin; Zhang, Hao; Zhang, Jun; Zhang, Jin Wen; Ye, Jiang Feng; Branch, D Ware

    2016-04-21

    Induction of labor (IOL) is a common practice in many parts of the world. However, the benefits and risks of preventive IOL for the mother and baby have yet to be critically assessed. This study is to investigate the effects of preventive IOL for non-urgent indications at term on maternal and neonatal outcomes. In this study, we applied a propensity score model to mimic a randomized clinical trial. Maternal and neonatal outcomes were compared between women with preventive IOL at 37-39 weeks of gestation and women with ongoing pregnancy (expectant management). The subjects were from the Consortium on Safe Labor, a study of over 200,000 births from 19 hospitals across the US from 2002 to 2008. Both nulliparous and multiparous women induced preventively for non-urgent indications at 37-38 weeks' gestation had lower rates of cesarean delivery compared to those delivered at later gestational weeks. However, preventive IOL was associated with increased risks of adverse neonatal outcomes (adjusted odds ratio [aOR] = 1.68, 95% confidence interval [CI], 0.97-2.92 for nulliparas; aOR = 2.22, 1.32-3.74 for multiparas) and admission to NICU (aOR = 1.48, 0.99-2.20 for nulliparas; aOR = 2.08, 1.47-2.96 for multiparas) at 37 weeks' gestation. A longer maternal hospital stay was found among all women with preventive IOL. Preventive IOL for non-urgent indications may be associated with a decreased risk of cesarean delivery at early term but increased risks of adverse neonatal outcomes at 37 weeks. It also results in a longer hospital stay than expectant management.

  6. Comparison of visual outcomes after bilateral implantation of extended range of vision and trifocal intraocular lenses.

    PubMed

    Ruiz-Mesa, Ramón; Abengózar-Vela, Antonio; Aramburu, Ana; Ruiz-Santos, María

    2017-06-26

    To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal. Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire. The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05). Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.

  7. Cumulative probability of neodymium: YAG laser posterior capsulotomy after phacoemulsification.

    PubMed

    Ando, Hiroshi; Ando, Nobuyo; Oshika, Tetsuro

    2003-11-01

    To retrospectively analyze the cumulative probability of neodymium:YAG (Nd:YAG) laser posterior capsulotomy after phacoemulsification and to evaluate the risk factors. Ando Eye Clinic, Kanagawa, Japan. In 3997 eyes that had phacoemulsification with an intact continuous curvilinear capsulorhexis, the cumulative probability of posterior capsulotomy was computed by Kaplan-Meier survival analysis and risk factors were analyzed using the Cox proportional hazards regression model. The variables tested were sex; age; type of cataract; preoperative best corrected visual acuity (BCVA); presence of diabetes mellitus, diabetic retinopathy, or retinitis pigmentosa; type of intraocular lens (IOL); and the year the operation was performed. The IOLs were categorized as 3-piece poly(methyl methacrylate) (PMMA), 1-piece PMMA, 3-piece silicone, and acrylic foldable. The cumulative probability of capsulotomy after cataract surgery was 1.95%, 18.50%, and 32.70% at 1, 3, and 5 years, respectively. Positive risk factors included a better preoperative BCVA (P =.0005; risk ratio [RR], 1.7; 95% confidence interval [CI], 1.3-2.5) and the presence of retinitis pigmentosa (P<.0001; RR, 6.6; 95% CI, 3.7-11.6). Women had a significantly greater probability of Nd:YAG laser posterior capsulotomy (P =.016; RR, 1.4; 95% CI, 1.1-1.8). The type of IOL was significantly related to the probability of Nd:YAG laser capsulotomy, with the foldable acrylic IOL having a significantly lower probability of capsulotomy. The 1-piece PMMA IOL had a significantly higher risk than 3-piece PMMA and 3-piece silicone IOLs. The probability of Nd:YAG laser capsulotomy was higher in women, in eyes with a better preoperative BCVA, and in patients with retinitis pigmentosa. The foldable acrylic IOL had a significantly lower probability of capsulotomy.

  8. Pigment dispersion and Artisan phakic intraocular lenses: crystalline lens rise as a safety criterion.

    PubMed

    Baïkoff, Georges; Bourgeon, Grégoire; Jodai, Horacio Jitsuo; Fontaine, Aline; Lellis, Fernando Viera; Trinquet, Laure

    2005-04-01

    To validate the theory that crystalline lens rise can be used as a safety criterion to prevent pigment dispersion in eyes with an Artisan phakic intraocular lens (IOL) (Ophtec BV). Monticelli Clinic, Marseilles, France. A comparative analysis of crystalline lens rise in 9 eyes with pigment dispersion and 78 eyes without dispersion was performed. All eyes had previous implantation of an Artisan IOL. Anterior segment imaging was done using an anterior chamber optical coherence tomography (AC OCT) prototype. Crystalline lens rise was defined by the distance between the anterior pole of the crystalline lens and the horizontal plane joining the opposite iridocorneal recesses. The study confirmed that crystalline lens rise can be considered a safety criterion for implantation of Artisan-type phakic IOLs. The higher the crystalline lens rise, the greater the risk for developing pigment dispersion in the area of the pupil. This complication occurred more frequently in hyperopic eyes than in myopic eyes. Results indicate there is little or no risk for pigment dispersion if the rise is less than 600 microm; 67% of eyes with a rise of 600 microm or more developed pupillary pigment dispersion. In some cases in which the IOL was loosely fixated, there was no traction on the iris root and dispersion was prevented or delayed. Crystalline lens rise should be considered a new safety criterion for Artisan phakic IOL implantation and should also be applied to other types of phakic IOLs. The distance remaining between the crystalline lens rise and a 600 microm theoretical safety level allows one to calculate how long the IOL can safely remain in the eye.

  9. Toric intraocular lens implantation versus astigmatic keratotomy to correct astigmatism during phacoemulsification.

    PubMed

    Titiyal, Jeewan S; Khatik, Mukesh; Sharma, Namrata; Sehra, Sri Vatsa; Maharana, Parfulla K; Ghatak, Urmimala; Agarwal, Tushar; Khokhar, Sudarshan; Chawla, Bhavana

    2014-05-01

    To compare toric intraocular lens (IOL) implantation and astigmatic keratotomy (AK) in correction of astigmatism during phacoemulsification. Tertiary care hospital. Prospective randomized trial. Consecutive patients with visually significant cataract and moderate astigmatism (1.25 to 3.00 diopters [D]) were randomized into 2 groups. Temporal clear corneal 2.75 mm phacoemulsification with toric IOL implantation was performed in the toric IOL group and with 30-degree coupled AK at the 7.0 mm optic zone in the keratotomy group. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, keratometry, topography, central corneal thickness, and endothelial cell density were evaluated preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. The study enrolled 34 eyes (34 patients), 17 in each group. There was no difference in UDVA or CDVA between the 2 groups at any follow-up visit. The mean preoperative and postoperative refractive cylinder was 2.00 D ± 0.49 (SD) and 0.33 ± 0.17 D, respectively, in the toric IOL group and 1.95 ± 0.47 D and 0.57 ± 0.41 D, respectively, in the keratotomy group (P=.10). The mean residual astigmatism at 3 months was 0.44 ± 1.89 @ 160 in the toric IOL group and 0.77 ± 1.92 @ 174 in the keratotomy group (P=.61). All eyes in the toric IOL group and 14 eyes (84%) in the keratotomy group achieved a residual refractive cylinder of 1.00 D or less (P=.17). Toric IOL implantation was comparable to AK in eyes with moderate astigmatism having phacoemulsification. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. The efficiency of aspheric intraocular lens according to biometric measurements.

    PubMed

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  11. Gray Matter Volume Reduction of Olfactory Cortices in Patients With Idiopathic Olfactory Loss

    PubMed Central

    Yao, Linyin; Pinto, Jayant Marian; Yi, Xiaoli; Li, Li; Peng, Peng

    2014-01-01

    Idiopathic olfactory loss (IOL) is a common olfactory disorder. Little is known about the pathophysiology of this disease. Previous studies demonstrated decreased olfactory bulb (OB) volume in IOL patients when compared with controls. The aim of our study was to investigate structural brain alterations in areas beyond the OB. We acquired T1-weighted magnetic resonance images from 16 patients with IOL and from 16 age- and sex-matched controls on a 3T scanner. Voxel-based morphometry (VBM) was performed using VBM8 toolbox and SPM8 in a Matlab environment. Psychophysical testing confirmed that patients had higher scores for Toyota and Takagi olfactometer and lower scores for Sniffin’ Sticks olfactory test than controls (t = 46.9, P < 0.001 and t = 21.4, P < 0.001, respectively), consistent with olfactory dysfunction. There was a significant negative correlation between the 2 olfactory tests (r = −0.6, P = 0.01). In a volume of interest analysis including primary and secondary olfactory areas, we found patients with IOL to exhibit gray matter volume loss in the orbitofrontal cortex, anterior cingulate cortex, insular cortex, parahippocampal cortex, and the piriform cortex. The present study indicates that changes in the central brain structures proximal to the OB occur in IOL. Further investigations of this phenomenon may be helpful to elucidate the etiology of IOL. PMID:25240014

  12. Posterior capsule opacification after implantation of a hydrogel intraocular lens

    PubMed Central

    Hayashi, K; Hayashi, H

    2004-01-01

    Aim: To compare the degree of posterior capsule opacification (PCO) in eyes with a hydrophilic hydrogel intraocular lens (IOL) with that in eyes with a hydrophobic acrylic IOL. Methods: Ninety five patients underwent a hydrogel IOL implantation in one eye and an acrylic IOL implantation in the opposite eye. The PCO value of these patients was measured using the Scheimpflug videophotography system at 1, 6, 12, 18, and 24 months postoperatively. The rate of neodymium:YAG (Nd:YAG) laser posterior capsulotomy and visual acuity were also evaluated. Results: The mean PCO value in the hydrogel group increased significantly (p<0.0001), while that in the acrylic group did not show significant change. The PCO value in the hydrogel group was significantly greater than that in the acrylic group throughout the follow up period. Kaplan-Meier survival analysis determined that the Nd:YAG capsulotomy rate in the hydrogel group was significantly higher than that in the acrylic group (p<0.0001). Mean visual acuity in the hydrogel group decreased significantly with time (p<0.0001), and became significantly worse than that in the acrylic group at 18 and 24 months postoperatively. Conclusion: Posterior capsule opacification in eyes with a hydrophilic hydrogel IOL is significantly more extensive than that in eyes with a hydrophobic acrylic IOL, and results in a significant impairment of visual acuity. PMID:14736768

  13. Extreme depth-of-field intraocular lenses

    NASA Astrophysics Data System (ADS)

    Baker, Kenneth M.

    1996-05-01

    A new technology brings the full aperture single vision pseudophakic eye's effective hyperfocal distance within the half-meter range. A modulated index IOL containing a subsurface zeroth order coherent microlenticular mosaic defined by an index gradient adds a normalizing function to the vergences or parallactic angles of incoming light rays subtended from field object points and redirects them, in the case of near-field images, to that of far-field images. Along with a scalar reduction of the IOL's linear focal range, this results in an extreme depth of field with a narrow depth of focus and avoids the focal split-up, halo, and inherent reduction in contrast of multifocal IOLs. A high microlenticular spatial frequency, which, while still retaining an anisotropic medium, results in a nearly total zeroth order propagation throughout the visible spectrum. The curved lens surfaces still provide most of the refractive power of the IOL, and the unique holographic fabrication technology is especially suitable not only for IOLs but also for contact lenses, artificial corneas, and miniature lens elements for cameras and other optical devices.

  14. Injectable suture device for intraocular lens fixation.

    PubMed

    Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L

    2015-12-01

    We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Optical ensemble analysis of intraocular lens performance through a simulated clinical trial with ZEMAX.

    PubMed

    Zhao, Huawei

    2009-01-01

    A ZEMAX model was constructed to simulate a clinical trial of intraocular lenses (IOLs) based on a clinically oriented Monte Carlo ensemble analysis using postoperative ocular parameters. The purpose of this model is to test the feasibility of streamlining and optimizing both the design process and the clinical testing of IOLs. This optical ensemble analysis (OEA) is also validated. Simulated pseudophakic eyes were generated by using the tolerancing and programming features of ZEMAX optical design software. OEA methodology was verified by demonstrating that the results of clinical performance simulations were consistent with previously published clinical performance data using the same types of IOLs. From these results we conclude that the OEA method can objectively simulate the potential clinical trial performance of IOLs.

  16. [The growth behavior of mouse fibroblasts on intraocular lens surface of various silicone and PMMA materials].

    PubMed

    Kammann, J; Kreiner, C F; Kaden, P

    1994-08-01

    Experience with intraocular lenses (IOL) made of PMMA dates back ca. 40 years, while silicone IOLs have been in use for only about 10 years. The biocompatibility of PMMA and silicone caoutchouc was tested in a comparative study investigating the growth of mouse fibroblasts on different IOL materials. Spectrophotometric determination of protein synthesis and liquid scintillation counting of DNA synthesis were carried out. The spreading of cells was planimetrically determined, and the DNA synthesis of individual cells in direct contact with the test sample was tested. The results showed that the biocompatibility of silicone lenses made of purified caoutchouc is comparable with that of PMMA lenses; there is no statistically significant difference. However, impurities arising during material synthesis result in a statistically significant inhibition of cell growth on the IOL surfaces.

  17. Characteristics of the retinal images of the eye optical systems with implanted intraocular lenses

    NASA Astrophysics Data System (ADS)

    Siedlecki, Damian; Zając, Marek; Nowak, Jerzy

    2007-04-01

    Cataract, or opacity of crystalline lens in the human eye is one of the most frequent reasons of blindness nowadays. Removing the pathologically altered crystalline lens and replacing it with artificial implantable intraocular lens (IOL) is practically the only therapy in this illness. There exist a wide variety of artificial IOL types on the medical market, differing in their material and design (shape). In this paper six exemplary models of IOL's made of PMMA, acrylic and silicone are considered. The retinal image quality is analyzed numerically on the basis of Liou-Brennan eye model with these IOL's inserted. Chromatic aberration as well as polychromatic Point Spread Function and Modulation Transfer Function are calculated as most adequate image quality measures. The calculations made with Zemax TM software show the importance of chromatic aberration correction.

  18. Intraocular lenses in age-related macular degeneration.

    PubMed

    Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Alio, Jorge L; Amat-Peral, Pedro; Tabernero, Juan

    2017-09-01

    The aim of this work is to review the lenses, assessing their advantages and disadvantages. We describe a total of seven types of intraocular lenses (IOLs) recommended for age-related macular degeneration (AMD). We used the PubMed web platform to search for implantable devices in various stages of AMD. We searched for both prospective and retrospective studies and also case reports. Clinical results in AMD patients have been described for a total of seven types of IOLs recommended for AMD: an implantable miniature telescope (IMT), IOL-VIP System, Lipshitz macular implant (LMI), sulcus-implanted Lipshitz macular implant, LMI-SI, Fresnel Prism Intraocular Lens, iolAMD and Scharioth Macula Lens. We conclude that to objectively ascertain the effectiveness and safety of these lenses, further independent clinical studies with longer follow-up data are necessary prior to the general use of these optical devices.

  19. A new surgical technique using steel suture for trans-scleral fixation of posterior chamber intraocular lenses

    PubMed Central

    Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam

    2013-01-01

    Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504

  20. Prevention of suture knot exposure in posterior chamber intraocular lens implantation by 4-point scleral fixation technique.

    PubMed

    Baykara, Mehmet; Avci, Remzi

    2004-01-01

    The results and complications of posterior chamber intraocular lens (IOL) implantation by a 4-point scleral fixation technique are described. Fifty eyes of 47 patients who underwent scleral-fixated IOL implantation were retrospectively evaluated. Twenty-one (42%) eyes had a history of trauma and 29 (58%) eyes had previously undergone cataract surgery. In all cases, IOL implantation by 4-point scleral fixation was performed and the knots of fixation sutures were rotated and buried in the globe. The IOL position was adjusted by suture rotation for best centration. The mean follow-up time was 7 +/- 4 months. Four (8%) eyes had minimal corneal edema preoperatively. Cystoid macular edema was noted in 2 (6.8%) eyes in the cataract surgery group and 8 (38%) eyes in the posttraumatic group. Two (9.5%) eyes in the posttraumatic group had atrophic macular changes and 1 (4.7%) had corneal scarring, which impaired vision. No complications such as knot exposure, tilting of the IOL, decentralization, or endophthalmitis were noted postoperatively. Postoperative mean corrected visual acuity was 0.4 +/- 0.3 in the posttraumatic group and 0.4 +/- 0.2 in the cataract surgery group. The 4-point scleral fixation technique resulted in no serious postoperative complications such as suture exposure and endophthalmitis. Because the knot can be rotated and buried in the globe, knot exposure is less likely to occur. This procedure is more effective than other techniques regarding IOL centralization.

  1. Hydrophilic acrylic intraocular lens as a drug-delivery system for fourth-generation fluoroquinolones.

    PubMed

    Kleinmann, Guy; Apple, David J; Chew, Jesse; Hunter, Brian; Stevens, Scott; Larson, Scott; Mamalis, Nick; Olson, Randall J

    2006-10-01

    To evaluate the ability and safety of a hydrophilic acrylic intraocular lens (IOL) as a drug-delivery system for commercially available gatifloxacin and moxifloxacin. David J. Apple, MD, Laboratories for Ophthalmic Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. Thirty rabbits were divided into 2 similar groups. In Group A (15 rabbits, 30 eyes), hydrophilic acrylic IOLs (C-flex, Rayner Intraocular Lenses, Ltd.) presoaked for 24 hours in commercially available solutions of gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL were implanted after evacuation of the crystalline lens. Group B (15 rabbits, 30 eyes) had topical preoperative and postoperative cataract prophylaxis with gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL; IOLs that were not presoaked were also implanted after evacuation of the crystalline lenses. In both groups, aqueous humor samples were taken 4, 8, or 12 hours after IOL implantation (5 eyes at each time point) to determine the antibiotic concentrations. Clinical examinations were performed 24 hours postoperatively. The antibiotic concentrations in Group A (presoaked IOLs) were statistically significantly higher than those in Group B (topical) for both antibiotics in all postoperative samples except moxifloxacin at 12 hours. In both groups, there was no statistically significant difference between the concentrations of the 2 antibiotics. No eye showed signs of clinical toxicity. Results show the C-flex IOL is a safe and effective drug-delivery system for fourth-generation fluoroquinolones.

  2. [Refractive precision and objective quality of vision after toric lens implantation in cataract surgery].

    PubMed

    Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J

    2012-10-01

    To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  3. Pathological evaluation of postmortem human eyes implanted with a new single-piece hydrophobic acrylic lens.

    PubMed

    Izak, Andrea M; Werner, Liliana; Pandey, Suresh K; Apple, David J

    2004-07-01

    To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.

  4. Introduction of a Toric Intraocular Lens to a Non-Refractive Cataract Practice: Challenges and Outcomes

    PubMed Central

    Kirwan, Clare; Nolan, John M; Stack, Jim; Dooley, Ian; Moore, Johnny; Moore, Tara CB; Beatty, Stephen

    2016-01-01

    Aim To identify challenges inherent in introducing a toric intraocular lens (IOL) to a non-refractive cataract practice, and evaluate residual astigmatism achieved and its impact on patient satisfaction. Methods Following introduction of a toric IOL to a cataract practice with all procedures undertaken by a single, non-refractive, surgeon (SB), pre-operative, intra-operative and post-operative data was analysed. Attenuation of anticipated post-operative astigmatism was examined, and subjectively perceived visual functioning was assessed using validated questionnaires. Results Median difference vector (DV, the induced astigmatic change [by magnitude and axis] that would enable the initial surgery to achieve intended target) was 0.93D; median anticipated DV with a non-toric IOL was 2.38D. One eye exhibited 0.75D residual astigmatism, compared to 3.8D anticipated residual astigmatism with a non-toric IOL. 100% of respondents reported satisfaction of ≥ 6/10, with 37.84% of respondents entirely satisfied (10/10). 17 patients (38.63%) reported no symptoms of dysphotopsia (dysphoptosia score 0/10), only 3 respondents (6.8%) reported a clinically meaningful level of dysphotopsia (≥ 4/10). Mean post-operative NEI VF-11 score was 0.54 (+/-0.83; scale 0 – 4). Conclusion Use of a toric IOL to manage astigmatism during cataract surgery results in less post-operative astigmatism than a non-toric IOL, resulting in avoidance of unacceptable post-operative astigmatism. PMID:27830188

  5. Effect of a modified optic edge design on visual function: textured-edge versus round-anterior, slope-side edge.

    PubMed

    Hayashi, Ken; Hayashi, Hideyuki

    2004-08-01

    To compare the impairment in visual function caused by glare with 2 acrylic intraocular lenses (IOLs) with different modified optic edges. Hayashi Eye Hospital, Fukuoka, Japan. Fifty-four patients had implantation of an IOL with a textured edge (Alcon MA60AC) in 1 eye and an IOL with a round-anterior, sloped-sided edge (AMO AR40e) in the opposite eye. Visual acuity was measured at 5 contrast visual targets (100%, 25%, 10%, 5%, and 2.5%) (contrast visual acuity) under photopic and mesopic conditions with and without a glare source approximately 1 month after surgery using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000). The mean mesopic contrast visual acuity at moderate- to low-contrast visual targets was significantly worse in the presence of a glare source in both groups, whereas photopic contrast visual acuity did not change significantly. There were no significant differences between the 2 groups in the mean visual acuity or in photopic or mesopic lighting contrast visual acuity with and without a glare source. Furthermore, there was no significant difference in loss of contrast visual acuity in the presence of glare. Mesopic contrast sensitivity with both acrylic IOLs was impaired significantly in the presence of glare, but the impairment of contrast sensitivity from glare was approximately the same between eyes with a textured-edge IOL and eyes with a round-anterior, sloped-sided edge IOL.

  6. [Analyzing and tracking preoperative and intraoperative astigmatism].

    PubMed

    Perez, M

    2012-03-01

    Precise evaluation of preoperative astigmatism is the first step optimizing outcomes. This begins with office-based evaluation of astigmatism; corneal astigmatism is evaluated by keratometry, traditionally by Javal keratometry, but now including topography, whether Placido- or elevation-based, which allows for detailed analysis of even irregular astigmatism, including the corneal periphery, which is invaluable. Aberrometers, essentially "super-auto refractors", allow the incorporation of additional data into the qualitative analysis of astigmatism. The correlation between these multiple preoperative data helps to differentiate between corneal and total astigmatism, to infer the lenticular astigmatism, and to integrate all of these data into the clinical decision-making process. Immediately preoperatively, the 0 and 180° axes are marked; then, with the aid of a special marker, the axis of alignment for the toric IOL is also marked. Once the cataract is removed, the toric IOL is injected and pre-aligned; the viscoelastic is carefully removed, particularly from between the IOL and posterior capsule, with the toric IOL being definitively aligned at this point. These alignment techniques represent a major advance, soon to be indispensible for toric IOL surgery, which will certainly continue to grow in the future. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  7. Supercritical impregnation and optical characterization of loaded foldable intraocular lenses using supercritical fluids.

    PubMed

    Bouledjouidja, Abir; Masmoudi, Yasmine; Li, Yanfeng; He, Wei; Badens, Elisabeth

    2017-10-01

    To prepare drug-loaded intraocular lenses (IOLs) used to combine cataract surgery with postoperative complication treatment through supercritical impregnation while preserving their optical properties. Aix-Marseille Université, CNRS, Centrale Marseille, Laboratoire de Mécanique, Modélisation & Procédés Propres, Marseille, France, and He University Eye Hospital, Liaoning Province, China. Experimental study. Supercritical impregnations of commercial foldable IOLs used in cataract surgery with ciprofloxacin (an antibiotic) and dexamethasone 21-phosphate disodium salt (an antiinflammatory drug) were performed in a noncontinuous mode. Impregnation amounts were determined through drug-release kinetic studies. The optical characterizations of IOLs were determined by evaluating the dioptric power and the imaging quality by determining the modulating transfer function (MTF) at a specified spatial frequency according to the International Organization for Standardization (ISO 11979-2:2014). Transparent IOLs presenting an effective impregnation were obtained with a prolonged drug delivery during approximately 10 days. Optical characterizations (dioptric powers and MTF values) show preserved optical properties after supercritical treatment/impregnation. Supercritical treatments/impregnations do not damage the optical properties of IOLs and are therefore adequate for the preparation of delivery devices used for cataract surgery. Copyright © 2017. Published by Elsevier Inc.

  8. Nonlinear geometric scaling of coercivity in a three-dimensional nanoscale analog of spin ice

    NASA Astrophysics Data System (ADS)

    Shishkin, I. S.; Mistonov, A. A.; Dubitskiy, I. S.; Grigoryeva, N. A.; Menzel, D.; Grigoriev, S. V.

    2016-08-01

    Magnetization hysteresis loops of a three-dimensional nanoscale analog of spin ice based on the nickel inverse opal-like structure (IOLS) have been studied at room temperature. The samples are produced by filling nickel into the voids of artificial opal-like films. The spin ice behavior is induced by tetrahedral elements within the IOLS, which have the same arrangement of magnetic moments as a spin ice. The thickness of the films vary from a two-dimensional, i.e., single-layered, antidot array to a three-dimensional, i.e., multilayered, structure. The coercive force, the saturation, and the irreversibility field have been measured in dependence of the thickness of the IOLS for in-plane and out-of-plane applied fields. The irreversibility and saturation fields change abruptly from the antidot array to the three-dimensional IOLS and remain constant upon further increase of the number of layers n . The coercive force Hc seems to increase logarithmically with increasing n as Hc=Hc 0+α ln(n +1 ) . The logarithmic law implies the avalanchelike remagnetization of anisotropic structural elements connecting tetrahedral and cubic nodes in the IOLS. We conclude that the "ice rule" is the base of mechanism regulating this process.

  9. Induction of labor in elderly nulliparous women.

    PubMed

    Hadar, Eran; Hiersch, Liran; Ashwal, Eran; Chen, Rony; Wiznitzer, Arnon; Gabbay-Benziv, Rinat

    2017-09-01

    Maternal age is an important consideration for antenatal care, labor and delivery. We aimed to evaluate the induction of labor (IoL) failure rates among elderly nulliparous women. We conducted a retrospective analysis of all nulliparous women at 34 + 0 to 41 + 6 weeks, undergoing cervical ripening by prostaglandin E2 (PGE2) vaginal insert. Study group included elderly (≥35 years) nulliparous and control group included non-elderly (<35 years) nulliparous women. Primary outcome was IoL failure rate and secondary outcome was cesarean delivery rate. Outcomes were compared between the groups by univariate analysis followed by regression analysis to adjust results to potential confounders. Of 537 women undergoing IoL, 69 (12.8%) were elderly. The univariate analysis demonstrated no difference in IoL failure rate (26.5% versus 34.8%, p = 0.502) between groups. However, elderly nulliparous women had higher rates of cesarean delivery (36.2% versus 21.4%, p = 0.009). This difference was no longer significant after adjustment for maternal body mass index, indication for delivery, birth weight and gestational age at delivery. Among nulliparous women, older maternal age is not associated with higher rates of IoL failure or cesarean deliveries.

  10. Extended depth of focus intraocular lens: Chromatic performance

    PubMed Central

    Millán, Maria S.; Vega, Fidel

    2017-01-01

    We describe a first-and-second-diffractive-order intraocular lens ((1st,2nd)DIOL) within the class of hybrid refractive-diffractive designs for intraocular lenses (IOLs) and analyse its properties of focus extension and compensation of longitudinal chromatic aberration (LCA), particularly for lenses with low addition. Power, energy efficiency and their wavelength dependence are extended from monofocal IOL and conventional bifocal zeroth-and-first-diffractive-order IOL ((0th,1st)DIOL) to (1st,2nd)DIOL of low addition. Compensation of LCA is experimentally assessed in optical bench through the through-focus energy efficiency of three Tecnis IOLs with red, green and blue illuminations: ZA9003 (monofocal), ZKB00 (bifocal (0th,1st)DIOL with + 2.75 D add) and Symfony ZXR00. We prove Tecnis Symfony ZXR00 IOL can be considered an example of (1st,2nd)DIOL design of low addition, with LCA compensation in both the distance and intermediate foci, whereas the bifocal (0th,1st)DIOL does not compensate in the distance focus. However, the energy efficiency of (1st,2nd)DIOL for wavelengths other than the design wavelength is markedly more asymmetric. PMID:28966865

  11. Unusual Internal Astigmatism Due to Severe Capsule Contraction Syndrome.

    PubMed

    Zéboulon, Pierre; Gatinel, Damien

    2018-01-01

    To describe a case of severe capsule contraction syndrome causing significant astigmatism due to intraocular lens (IOL) folding. Case report. Capsule fibrosis and contraction resulted in bending of the hydrophilic IOL along its long axis. Anterior Nd:YAG capsulotomy resolved the situation and restored the patient's visual acuity. Hydrophilic IOLs are more susceptible to capsule contraction due to the increased flexibility of highly hydrated materials. They should be avoided in patients at risk of capsule contraction to prevent ocular complications. [J Refract Surg. 2018;34(1):65-67.]. Copyright 2018, SLACK Incorporated.

  12. Features of optical surfaces of multifocal diffractive-refractive eye lenses

    NASA Astrophysics Data System (ADS)

    Lenkova, G. A.

    2017-09-01

    This paper considers shape features of the surface structures of multifocal intraocular lenses (IOLs), which, unlike bifocal IOLs, generate additional foci or extends the depth of focus, which not only corrects near and far vision but also provides good vision at intermediate distances. Expansion of the field of clear vision is achieved due to the effects of diffraction, interference, and refraction (change in the radius of curvature of the lens surface). The optical characteristics of the most famous multifocal IOLs (trifocal and quadrafocal lenses and lenses with extended focal area) are given.

  13. In vivo subjective and objective longitudinal chromatic aberration after bilateral implantation of the same design of hydrophobic and hydrophilic intraocular lenses.

    PubMed

    Vinas, Maria; Dorronsoro, Carlos; Garzón, Nuria; Poyales, Francisco; Marcos, Susana

    2015-10-01

    To measure the longitudinal chromatic aberration in vivo using psychophysical and wavefront-sensing methods in patients with bilateral implantation of monofocal intraocular lenses (IOLs) of similar aspheric design but different materials (hydrophobic Podeye and hydrophilic Poday). Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain. Prospective observational study. Measurements were performed with the use of psychophysical (480 to 700 nm) and wavefront-sensing (480 to 950 nm) methods using a custom-developed adaptive optics system. Chromatic difference-of-focus curves were obtained from best-focus data at each wavelength, and the longitudinal chromatic aberration was obtained from the slope of linear regressions to those curves. The longitudinal chromatic aberration from psychophysical measurements was 1.37 diopters (D) ± 0.08 (SD) (hydrophobic) and 1.21 ± 0.08 D (hydrophilic). From wavefront-sensing, the longitudinal chromatic aberration was 0.88 ± 0.07 D and 0.73 ± 0.09 D, respectively. At 480 to 950 nm, the longitudinal chromatic aberration was 1.27 ± 0.09 D (hydrophobic) and 1.02 ± 0.13 D (hydrophilic). The longitudinal chromatic aberration was consistently higher in eyes with the hydrophobic IOL than in eyes with the hydrophilic IOL (a difference of 0.16 D and 0.15 D, respectively). Similar to findings in young phakic eyes, the longitudinal chromatic aberration from the psychophysical method was consistently higher than from wavefront-sensing, by 0.48 D (35.41%) for the hydrophobic IOL and 0.48 D (39.43%) for the hydrophilic IOL. Longitudinal chromatic aberrations were smaller with hydrophilic IOLs than with hydrophobic IOLs of the same design. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Comparison of Visual Quality after Implantation of Big Bag and Akreos Adapt Intraocular Lenses in Patients with High Myopia.

    PubMed

    Ma, Shengsheng; Zheng, Dongjian; Lin, Ling; Meng, Fanjian; Yuan, Yonggang

    2015-03-01

    To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens (IOL) in patients diagnosed with high myopia complicated with cataract. This was a randomized prospective control study. The patients with high myopia. complicated with cataract, with axial length ≥ 28 mm, and corneal astigmatism ≤ 1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation. At 3 months after surgery, intraocular high-order aberration was measured by a Tracey-iTrace wavefront aberrometer at a pupil diameter of 5 mm in an absolutely dark room and statistically compared between two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Penta-cam three-dimensional anterior segment analyzer. The tilt and decentration of the IOL were calculated by Image-pro plus 6.0 imaging analysis software and statistically compared between two groups. In total, 127 patients (127 eyes), including 52 males and 75 females, were enrolled in this study. The total high-order aberration and coma in the Akreos Adapt group (59 eyes) were significantly higher compared with those in the Big Bag (P < 0.05). The clover and spherical aberration did not differ between the two groups (P > 0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group (both P < 0.05), whereas the tilt of IOL did not significantly differ between the two groups (P > 0.05). Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberration. Coma is the major difference between the two groups.

  15. Long-Term Visual Outcomes of Secondary Intraocular Lens Implantation in Children with Congenital Cataracts

    PubMed Central

    Jiang, Yongxiang; Lu, Yi

    2015-01-01

    Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at initial cataract extraction, compliance with amblyopia therapy, and refractive error. PMID:26230501

  16. An angle-supported foldable phakic intraocular lens for correction of myopia: A five-year follow-up.

    PubMed

    Alió, J L; Plaza-Puche, A B; Cavas, F; Yébana Rubio, P; Sala, E

    2017-01-01

    To evaluate the efficacy and safety of an angle-supported foldable phakic intraocular lens (pIOL) for the correction of moderate to high myopia after 5 years follow-up. Prospective and retrospective, observational, longitudinal, non-randomised consecutive series of cases conducted on a total of 100 eyes of 67 patients with moderate to high myopia implanted with an Acrysof Cachet pIOL (Alcon Laboratories Inc.) with the aim of minimising the refractive error. The ages ranged between 18 to 60years. Uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity (CDVA), endothelial cells density, pIOL position, intraocular pressure, and complications were recorded preoperatively and during the 5 year follow-up. Five years after implantation, the mean manifest spherical equivalent refraction reduced significantly from -11.62±3.35 dioptres (D) to -0.33±0.85D. UDVA was 20/20 or better in 5 of 25 cases (20%), and 20/40 or better in 22 cases (88%). CDVA was 20/20 or better in 17 cases (68%), and 20/32 or better in 23 cases (92%) of eyes. The residual refractive error was within ±0.50D of emmetropia in 12 cases (48%), and within ±1.00D in 19 cases (76%). Mean endothelial cell loss at 5 years was 11.8% central, and 13.7% peripheral. Mean endothelium-pIOL distance was 2.11±0.18mm, and mean pIOL-crystalline distance was 0.88±0.20mm. This angle supported pIOL provided a favourable refractive correction and predictability, as well as acceptable safety in patients with moderate to high myopia. Although endothelial cell density decreased over 5years, the results are within the range reported in previous studies with other pIOLs. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. SURGICAL OUTCOME OF SIMULTANEOUS INTRAOCULAR LENS RESCUE AND SUTURELESS INTRASCLERAL TUNNEL FIXATION OF DISLOCATED INTRAOCULAR LENSES.

    PubMed

    Kim, Min; Lee, Dong H; Koh, Hyoung J; Lee, Sung C; Kim, Sung S

    2015-07-01

    To report short-term surgical outcomes of single-stage simultaneous rescue and sutureless intrascleral fixation of dislocated intraocular lens (IOLs). Sixteen eyes of 16 patients who underwent simultaneous rescue and intrascleral fixation of dislocated 3-piece IOLs were retrospectively evaluated. Partial thickness limbal-based scleral flaps (2.0 × 2.0 mm) were created, and a 22-gauge round needle was used to create a sclerotomy at 1.5 mm from the limbus under the previously created scleral flap, and a 23-gauge trans pars plana vitrectomy was performed. Bimanual maneuvers using two 23-gauge end-grasping forceps under chandelier illumination and a wide-angle viewing system enabled 1 step rescue of IOLs from the posterior vitreous cavity with 1 hand and simultaneous haptic externalization through sclerotomy with the other hand. An externalized haptic was placed into the 3-mm intrascleral tunnel created using a bent 26-gauge needle. Fibrin glue was used to fixate haptics and close the scleral flaps. Intraocular lenses were successfully rescued and sclera-fixated through intrascleral tunnels in all 16 eyes (mean age, 56.56 ± 19.89 years). The mean preoperative logarithm of the minimum angle of resolution best-corrected visual acuity was 0.92 ± 0.68, and this significantly improved at 6 months to 0.289 ± 0.36 (P = 0.003). During the follow-up period (10.1 ± 3.21 months), no significant change of endothelial cell count or central foveal thickness was noted postoperatively (P = 0.203 and P = 0.979, respectively). There were no significant postoperative complications such as IOL dislocation, IOL decentration, retinal detachment, endophthalmitis, or postoperative hypotony. Simultaneous rescue and sutureless intrascleral haptic fixation of dislocated 3-piece IOLs using bimanual maneuvers is an effective, safe, and minimally invasive surgical method to rescue and fixate the dislocated IOL without further explant.

  18. Staphylococcus epidermidis biofilm formation and structural organization on different types of intraocular lenses under in vitro flow conditions.

    PubMed

    Baillif, Stéphanie; Leduff, Frank; Hartmann, Daniel J; Kodjikian, Laurent

    2013-01-01

    To compare the adherence and structural organization of Staphylococcus epidermidis biofilm on intraocular lenses (IOLs). IOLs made of 3 different biomaterials [polymethyl methacrylate (PMMA), hydrophilic acrylic or hydrophobic acrylic] were incubated into an S. epidermidis bacterial solution. Scanning electron microscopy was used to count the bound bacteria and to analyze the structural biofilm architecture. After 4-6 h of incubation, adherence was statistically weakest on the hydrophilic acrylic polymer. On the hydrophobic acrylic material, the bacterial cells tended to cover the substratum in a horizontal spread in a continuous monolayer. On the hydrophilic acrylic material or on the PMMA material bacterial cells tended to form only few, small scattered cell clusters. The data suggest that the pattern of S. epidermidis adhesion varies with the IOL biomaterial. Hydrophobic IOLs seem to be more permissive to S. epidermidis adhesion. Copyright © 2013 S. Karger AG, Basel.

  19. A novel full-angle scanning light scattering profiler to quantitatively evaluate forward and backward light scattering from intraocular lenses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Bennett N., E-mail: bennett.walker@fda.hhs.gov; Office of Device Evaluation, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993; James, Robert H.

    Glare, glistenings, optical defects, dysphotopsia, and poor image quality are a few of the known deficiencies of intraocular lenses (IOLs). All of these optical phenomena are related to light scatter. However, the specific direction that light scatters makes a critical difference between debilitating glare and a slightly noticeable decrease in image quality. Consequently, quantifying the magnitude and direction of scattered light is essential to appropriately evaluate the safety and efficacy of IOLs. In this study, we introduce a full-angle scanning light scattering profiler (SLSP) as a novel approach capable of quantitatively evaluating the light scattering from IOLs with a nearlymore » 360° view. The SLSP method can simulate in situ conditions by controlling the parameters of the light source including angle of incidence. This testing strategy will provide a more effective nonclinical approach for the evaluation of IOL light scatter.« less

  20. Postoperative Refractive Errors Following Pediatric Cataract Extraction with Intraocular Lens Implantation.

    PubMed

    Indaram, Maanasa; VanderVeen, Deborah K

    2018-01-01

    Advances in surgical techniques allow implantation of intraocular lenses (IOL) with cataract extraction, even in young children. However, there are several challenges unique to the pediatric population that result in greater degrees of postoperative refractive error compared to adults. Literature review of the techniques and outcomes of pediatric cataract surgery with IOL implantation. Pediatric cataract surgery is associated with several sources of postoperative refractive error. These include planned refractive error based on age or fellow eye status, loss of accommodation, and unexpected refractive errors due to inaccuracies in biometry technique, use of IOL power formulas based on adult normative values, and late refractive changes due to unpredictable eye growth. Several factors can preclude the achievement of optimal refractive status following pediatric cataract extraction with IOL implantation. There is a need for new technology to reduce postoperative refractive surprises and address refractive adjustment in a growing eye.

  1. Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation.

    PubMed

    Hirnschall, Nino; Norrby, Sverker; Weber, Maria; Maedel, Sophie; Amir-Asgari, Sahand; Findl, Oliver

    2015-01-01

    To include intraoperative measurements of the anterior lens capsule of the aphakic eye into the intraocular lens power calculation (IPC) process and to compare the refractive outcome with conventional IPC formulae. In this prospective study, a prototype operating microscope with an integrated continuous optical coherence tomography (OCT) device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior lens capsule position after implanting a capsular tension ring (CTR). Optical biometry (intraocular lens (IOL) Master 500) and ACMaster measurements (Carl Zeiss Meditec AG, Germany) were performed before surgery. Autorefraction and subjective refraction were performed 3 months after surgery. Conventional IPC formulae were compared with a new intraoperatively measured anterior chamber depth (ACD) (ACDIntraOP) partial least squares regression (PLSR) model for prediction of the postoperative refractive outcome. In total, 70 eyes of 70 patients were included. Mean axial eye length (AL) was 23.3 mm (range: 20.6-29.5 mm). Predictive power of the intraoperative measurements was found to be slightly better compared to conventional IOL power calculations. Refractive error dependency on AL for Holladay I, HofferQ, SRK/T, Haigis and ACDintraOP PLSR was r(2)=-0.42 (p<0.0001), r(2)=-0.5 (p<0.0001), r(2)=-0.34 (p=0.010), r(2)=-0.28 (p=0.049) and r(2)<0.001 (p=0.866), respectively, ACDIntraOP measurements help to better predict the refractive outcome and could be useful, if implemented in fourth-generation IPC formulae. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Sulcus implantation of a 3-piece, 6.0 mm optic, hydrophobic foldable acrylic intraocular lens in phacoemulsification complicated by posterior capsule rupture.

    PubMed

    Brazitikos, Periklis D; Balidis, Miltiadis O; Tranos, Paris; Androudi, Sofia; Papadopoulos, Nick T; Tsinopoulos, Ioannis T; Karabatakis, Vasilios; Stangos, Nikolaos T

    2002-09-01

    To evaluate the safety of implanting a 3-piece, 6.0 mm optic, foldable acrylic intraocular lens (IOL) in cases of posterior capsule rupture during phacoemulsification. Department of Ophthalmology, Ahepa Hospital, Aristotle University Medical School, and Interbalkan Medical Center, Thessaloniki, Greece. This prospective noncomparative case series included 28 eyes (28 patients) having phacoemulsification complicated by extensive posterior capsule rupture with or without vitreous loss. In all eyes, a 3-piece, 6.0 mm optic, foldable acrylic IOL (AcrySof MA60BM, Alcon) was implanted in the sulcus. Postoperative examination included best corrected visual acuity (BCVA), anterior segment biomicroscopy, IOL centralization and position, intraocular pressure (IOP), and fundus biomicroscopy. The follow-up was 6 months. The most common postoperative complications were transient corneal edema in 12 eyes and increased IOP in 11 eyes. Slight asymptomatic decentralization from the center of the pupil (1.0 to 2.0 mm) and pseudophacodonesis were observed in 5 eyes each. Friction of the IOL with the iris occurred in 1 eye. Clinically significant cystoid macular edema occurred in 3 eyes. The final BCVA was between 20/15 and 20/25 in 18 patients, 20/30 in 2, between 20/40 and 20/50 in 4, and between 20/60 and 20/200 in 4. AcrySof IOL implantation in the sulcus during phacoemulsification complicated by posterior capsule rupture preserved the advantages of small-incision surgery. The postoperative behavior and centralization of the IOLs resembled those of poly(methyl methacrylate) lenses.

  3. A Multicenter Retrospective Survey of Refractive Surgery in 78,248 Eyes.

    PubMed

    Kamiya, Kazutaka; Igarashi, Akihito; Hayashi, Ken; Negishi, Kazuno; Sato, Masaki; Bissen-Miyajima, Hiroko

    2017-09-01

    To retrospectively evaluate the current practice, trends, and outcomes of refractive surgery in Japan. This multicenter survey comprised 78,248 eyes of 39,727 consecutive patients who underwent refractive surgery at 45 major institutions in Japan. The corresponding ophthalmologists responded to a selfadministered questionnaire. The authors especially evaluated the safety, efficacy, predictability, stability, and adverse events of LASIK and phakic intraocular lens (IOL) implantation 3 months postoperatively. The most common refractive surgery was LASIK (90.9%), followed by corneal inlay (5.0%), posterior chamber phakic IOL implantation (1.3%), laser-assisted subepithelial keratomileusis (1.0%), refractive lens exchange (0.9%), photorefractive keratectomy (0.3%), and refractive lenticule extraction (0.2%). For subgroup analysis, 69,987 eyes (99.5%) and 67,512 eyes (95.9%) achieved corrected and uncorrected distance visual acuity of 20/20 or better, respectively, after LASIK, and 935 eyes (98.8%) and 890 eyes (94.1%), respectively, after phakic IOL implantation. There were 69,176 eyes (98.3%) and 908 eyes (96.0%) within ±1.00 diopter (D) of the attempted correction after LASIK and phakic IOL implantation, respectively. There were 1,926 eyes (2.7%) and 1 eye (0.1%) with changes in refraction of 1.00 D or less from 1 week to 3 months after LASIK and phakic IOL implantation, respectively. No vision-threatening complications occurred in any case. According to this survey, LASIK remains the most prevalent surgical technique in Japan. Both LASIK and phakic IOL implantation offered good safety and efficacy outcomes, yielding predictable and stable results. [J Refract Surg. 2017;33(9):598-602.]. Copyright 2017, SLACK Incorporated.

  4. Calcification of Hydrophilic Acrylic Intraocular Lenses With a Hydrophobic Surface: Laboratory Analysis of 6 Cases.

    PubMed

    Gartaganis, Sotirios P; Prahs, Philipp; Lazari, Eftichia D; Gartaganis, Panos S; Helbig, Horst; Koutsoukos, Petros G

    2016-08-01

    To investigate the nature and characteristic features of deposits causing opacification of intraocular lenses (IOLs) based on the examination of clinical findings using scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDX) analysis. Retrospective, observational case series. This is a multicenter study of 6 hydrophilic acrylic IOLs (Lentis LS-502-1; Oculentis GmbH, Berlin, Germany) with a hydrophobic surface that were explanted from 5 patients because of opacification. Three patients had an uncomplicated phacoemulsification. One patient underwent combined phacoemulsification and pars plana vitrectomy for retinal detachment and later silicone oil endotamponade owing to redetachment. The last patient had a pars plana vitrectomy and silicone oil instillation combined with phacoemulsification for tractive retinal detachment and diabetic retinopathy. The explanted lenses were submitted to our laboratory and were examined by SEM and EDX in order to identify the morphologic features and the composition of the deposits. SEM and EDX analyses confirmed the presence of calcific deposits in the interior of the opacified hydrophilic IOLs, with a pattern showing the formation of lumps on the surface. The lumps were due to subsurface formation of calcium phosphate crystalline deposits. The crystallite clusters seemed to diffuse from the IOL interior to the surface. We demonstrated the calcification pattern of the hydrophilic IOL (Lentis LS-502-1) with a hydrophobic surface. Although hydrophilic acrylic lenses have a hydrophobic surface, the development of calcification is a possible threat initiating from the hydrophilic subsurface of the IOLs. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Opacification of piggyback IOLs associated with an amorphous material attached to interlenticular surfaces.

    PubMed

    Werner, L; Shugar, J K; Apple, D J; Pandey, S K; Escobar-Gomez, M; Visessook, N; Evans, B B

    2000-11-01

    To report the pathological and ultrastructural features and interval surgical management of an atypical case of opacification between piggyback intraocular lenses (IOLs). Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, and Nature Coast EyeCare Institute and Surgery Center, Perry, Florida, USA. Opacification between 2 acrylic piggyback lenses was observed 16 months after implantation, with decreased best corrected visual acuity and a hyperopic shift. Elschnig pearls were observed in the peripheral interface between the lenses, and the central interface was occupied by an amorphous material. The pearls were surgically aspirated, but attempts to remove the central material were unsuccessful. The lenses were explanted and sent to the laboratory. Staining with hematoxylin and eosin (H&E), examination under a light microscope, and scanning electron microscopic analysis were performed. The surfaces of the anterior IOL were relatively clear. The amorphous material, mostly attached to the center of the anterior surface of the posterior IOL, was homogeneously stained with H&E. No cell nucleus was observed in this region. Scanning electron microscopy showed that the IOL edge presented a smooth, regular surface relatively free of deposits. The most central region was covered by an irregular layer of an amorphous compact material with some cracks, fissures, or both on its surface. Although the exact composition of the material between the lenses could not be established, hypotheses were advanced to understand the pathological mechanism associated with this condition. This case is different from those in previous reports of opacification composed of cortex and cells between piggyback IOLs.

  6. Evaluation of the impact of light scatter from glistenings in pseudophakic eyes.

    PubMed

    DeHoog, Edward; Doraiswamy, Anand

    2014-01-01

    To study the impact of light scatter from glistenings in pseudophakic eyes using ray tracing in a model eye Department of Research, Advanced Vision Science, Inc., Goleta, California, USA. Mathematical modeling and simulation. A pseudophakic eye model was constructed in Zemax using the Arizona eye model as the basis. The Mie scattering theory was used to describe the intensity and direction of light as it scatters for a spherical particle immersed in a given media (intraocular lens [IOL]). The modeling and evaluation of scatter and modulation transfer function (MTF) were performed for several biomaterials with various size and density of glistenings under scotopic, mesopic, and photopic conditions. As predicted by the Mie theory, the amount of scatter was a function of the relative difference in refractive index between the media and the scatterer, the size of the scatterer, and the volume fraction of the scatterer. The simulation demonstrated that an increase in density of glistenings can lead to a significant drop in the MTF of the IOL and the pseudophakic eye. This effect was more pronounced in IOLs with smaller cavitations, and the observation was consistent for all tested biomaterials. Mathematical modeling demonstrated that glistenings in IOLs will lead to reduction in the MTF of the IOL and the pseudophakic eye. The loss in MTF was more pronounced at high densities and small cavitation sizes across all biomaterials. Inconsistent and poor clinical quantification of glistenings in IOLs may explain some inconsistencies in the literature. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Adaptive Calibration of Dynamic Accommodation—Implications for Accommodating Intraocular Lenses

    PubMed Central

    Schor, Clifton M.; Bharadwaj, Shrikant R.

    2009-01-01

    PURPOSE When the aging lens is replaced with prosthetic accommodating intraocular lenses (IOLs), with effective viscoelasticities different from those of the natural lens, mismatches could arise between the neural control of accommodation and the biomechanical properties of the new lens. These mismatches could lead to either unstable oscillations or sluggishness of dynamic accommodation. Using computer simulations, we investigated whether optimal accommodative responses could be restored through recalibration of the neural control of accommodation. Using human experiments, we also investigated whether the accommodative system has the capacity for adaptive recalibration in response to changes in lens biomechanics. METHODS Dynamic performance of two accommodating IOL prototypes was simulated for a 45-year-old accommodative system, before and after neural recalibration, using a dynamic model of accommodation. Accommodating IOL I, a prototype for an injectable accommodating IOL, was less stiff and less viscous than the natural 45-year-old lens. Accommodating IOL II, a prototype for a translating accommodating IOL, was less stiff and more viscous than the natural 45-year-old lens. Short-term adaptive recalibration of dynamic accommodation was stimulated using a double-step adaptation paradigm that optically induced changes in neuromuscular effort mimicking responses to changes in lens biomechanics. RESULTS Model simulations indicate that the unstable oscillations or sluggishness of dynamic accommodation resulting from mismatches between neural control and lens biomechanics might be restored through neural recalibration. CONCLUSIONS Empirical measures reveal that the accommodative system is capable of adaptive recalibration in response to optical loads that simulate effects of changing lens biomechanics. PMID:19044245

  8. Preterm Induction of Labor: Predictors of Vaginal Delivery and Labor Curves

    PubMed Central

    Feghali, Maisa; Timofeev, Julia; Huang, Chun-Chih; Driggers, Rita; Miodovnik, Menachem; Landy, Helain J.; Umans, Jason G.

    2014-01-01

    Objective To evaluate the labor curves of patients undergoing preterm induction of labor (IOL) and assess possible predictors of vaginal delivery (VD). Study Design Data from the NICHD Consortium on Safe Labor were analyzed. A total of 6,555 women undergoing medically-indicated IOL before 37 weeks gestational age (GA) were included in this analysis. Patients were divided into four groups based on gestational age: A: 24-27+6, B: 28-30+6, C: 31-33+6, and D: 34-36+6 weeks. Pregnant women with a contraindication to VD, IOL at or after 37 weeks and those without data from cervical exam on admission were excluded. ANOVA was used to assess differences between GA groups. Multiple logistic regression was used to assess predictors of VD. A repeated measures analysis was used to determine average labor curves. Results Rates of vaginal live births increased with GA, from 35% (Group A) to 76% (Group D). Parous women [odds ratio (OR)=6.78, 95% confidence interval (CI) 6.38-7.21] and those with a favorable cervix at the start of IOL (OR=2.35, 95% CI 2.23-2.48) were more likely to deliver vaginally. Analysis of labor curves in nulliparous women showed shorter duration of labor with increasing GA; the active phase of labor was, however, similar across all GA. Conclusion The majority of women undergoing medically-indicated preterm IOL between 24 and 36+6 weeks’ GA deliver vaginally. The strongest predictor of VD was parity. Preterm IOL had a limited influence on estimated labor curves across gestational age. PMID:25068566

  9. Consecutive case series of 244 age-related macular degeneration patients undergoing implantation with an extended macular vision IOL.

    PubMed

    Qureshi, Muhammad A; Robbie, Scott J; Hengerer, Fritz H; Auffarth, Gerd U; Conrad-Hengerer, Ina; Artal, Pablo

    2018-03-01

    To determine safety and visual outcomes in eyes with age-related macular degeneration (AMD) implanted with a novel intraocular lens (IOL) that delivers an optimized retinal image to all macular areas within 10 degrees of retinal eccentricity. This was a consecutive case series of 244 eyes with dry/stable wet AMD and logMAR visual acuity ≥0.3 implanted with iolAMD Eyemax mono TM (London Eye Hospital Pharma), a single-piece, injectable, hydrophobic acrylic IOL sited in the capsular bag. Primary outcome was safety. Secondary outcomes were changes in corrected distance visual acuity (CDVA) and corrected near visual acuity (CNVA) (logMAR). Mean age at surgery was 80 years. Mean duration of follow-up was 3 months (range 1-16 months). No eyes had worsening of CDVA. Frequency of perioperative complications was equivalent to standard IOL implantation. Postoperative refractive outcomes were within ±1 D of the target refraction in 88% of cases. Mean preoperative CDVA improved from 1.06 to 0.71 postoperatively (mean of differences -0.35; 95% confidence interval [CI] -0.3886 to -0.3223; p<0.0001), equating to an approximate Early Treatment Diabetic Retinopathy Study gain of 18 letters. Mean preoperative CNVA (N-point; logMAR conversion) improved from 1.36 to 0.88 postoperatively (mean of differences -0.48; 95% CI -0.53 to -0.44; p<0.0001). This novel IOL appears safe in the short to medium term. Improvements in postoperative CDVA and CNVA exceed those observed with standard implants.

  10. Near-point string: Simple method to demonstrate anticipated near point for multifocal and accommodating intraocular lenses.

    PubMed

    George, Monica C; Lazer, Zane P; George, David S

    2016-05-01

    We present a technique that uses a near-point string to demonstrate the anticipated near point of multifocal and accommodating intraocular lenses (IOLs). Beads are placed on the string at distances corresponding to the near points for diffractive and accommodating IOLs. The string is held up to the patient's eye to demonstrate where each of the IOLs is likely to provide the best near vision. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. [Evaluation of the surface of the new intraocular lenses in the scanning electron microscope].

    PubMed

    Kałuzny, B J; Szatkowski, J; Kałuzny, J J

    2001-01-01

    To evaluate the surface of the new PC IOLs commercially available in Poland in 2000. Representative samples of new posterior chamber IOLs produced by 6 different companies (Alcon, Lensita, Medicontur, Opsia, Rayner, Storz), 5 of each, underwent surface examination with Novoscan 30 scanning electron microscope. Although, in general, smooth surface of optic and haptic parts were observed, three samples with irregularities were found. Comparing to previous evaluation performed in 1994, significant improvement in quality of IOLs surface was noted. No considerable differences in this field between above mentioned producers were observed.

  12. Influence of surface light scattering in hydrophobic acrylic intraocular lenses on laser beam transmittance.

    PubMed

    Shiraya, Tomoyasu; Kato, Satoshi; Minami, Keiichiro; Miyata, Kazunori

    2017-02-01

    The aim of this study was to experimentally examine the changes in the transmittances of photocoagulation lasers when surface light scattering increases in AcrySof intraocular lenses (IOLs). SA60AT IOLs (Alcon) were acceleratingly aging for 0, 3, 5, and 10 years to simulate surface light scattering, and the surface light-scattering intensities of both IOL surfaces were measured using a Scheimpflug photographer. The powers of laser beams that passed from a laser photocoagulator through the aged IOLs were measured at 532, 577, and 647 nm. Changes in the laser power and transmittance with the years of aging and the intensities of surface light scattering were examined. Although the intensity of surface light scattering increased with the years of aging, the laser power did not change with the years of aging (P > 0.30, Kruskal-Wallis test). There were no significant changes in the laser transmittance with the years of aging or the laser wavelength (P > 0.30 and 0.57, respectively). The intensity of surface light scattering revealed no significant association with the laser transmittance at any wavelength (P > 0.37, liner regression). The increases in the surface light scattering of the AcrySof IOLs would not influence retinal photocoagulation treatments for up to 10 years after implantation.

  13. Comparison of two laboratory-based systems for evaluation of halos in intraocular lenses

    PubMed Central

    Alexander, Elsinore; Wei, Xin; Lee, Shinwook

    2018-01-01

    Purpose Multifocal intraocular lenses (IOLs) can be associated with unwanted visual phenomena, including halos. Predicting potential for halos is desirable when designing new multifocal IOLs. Halo images from 6 IOL models were compared using the Optikos modulation transfer function bench system and a new high dynamic range (HDR) system. Materials and methods One monofocal, 1 extended depth of focus, and 4 multifocal IOLs were evaluated. An off-the-shelf optical bench was used to simulate a distant (>50 m) car headlight and record images. A custom HDR system was constructed using an imaging photometer to simulate headlight images and to measure quantitative halo luminance data. A metric was developed to characterize halo luminance properties. Clinical relevance was investigated by correlating halo measurements to visual outcomes questionnaire data. Results The Optikos system produced halo images useful for visual comparisons; however, measurements were relative and not quantitative. The HDR halo system provided objective and quantitative measurements used to create a metric from the area under the curve (AUC) of the logarithmic normalized halo profile. This proposed metric differentiated between IOL models, and linear regression analysis found strong correlations between AUC and subjective clinical ratings of halos. Conclusion The HDR system produced quantitative, preclinical metrics that correlated to patients’ subjective perception of halos. PMID:29503526

  14. Growth factor restriction impedes progression of wound healing following cataract surgery: identification of VEGF as a putative therapeutic target

    PubMed Central

    Eldred, Julie A.; McDonald, Matthew; Wilkes, Helen S.; Spalton, David J.; Wormstone, I. Michael

    2016-01-01

    Secondary visual loss occurs in millions of patients due to a wound-healing response, known as posterior capsule opacification (PCO), following cataract surgery. An intraocular lens (IOL) is implanted into residual lens tissue, known as the capsular bag, following cataract removal. Standard IOLs allow the anterior and posterior capsules to become physically connected. This places pressure on the IOL and improves contact with the underlying posterior capsule. New open bag IOL designs separate the anterior capsule and posterior capsules and further reduce PCO incidence. It is hypothesised that this results from reduced cytokine availability due to greater irrigation of the bag. We therefore explored the role of growth factor restriction on PCO using human lens cell and tissue culture models. We demonstrate that cytokine dilution, by increasing medium volume, significantly reduced cell coverage in both closed and open capsular bag models. This coincided with reduced cell density and myofibroblast formation. A screen of 27 cytokines identified nine candidates whose expression profile correlated with growth. In particular, VEGF was found to regulate cell survival, growth and myofibroblast formation. VEGF provides a therapeutic target to further manage PCO development and will yield best results when used in conjunction with open bag IOL designs. PMID:27076230

  15. Significant Axial Elongation with Minimal Change in Refraction in 3- to 6-Year-Old Chinese Preschoolers: The Shenzhen Kindergarten Eye Study.

    PubMed

    Guo, Xinxing; Fu, Min; Ding, Xiaohu; Morgan, Ian G; Zeng, Yangfa; He, Mingguang

    2017-12-01

    To document the distribution of ocular biometry and to evaluate its associations with refraction in a group of Chinese preschoolers. Population-based cross-sectional study. A total of 1133 preschoolers 3 to 6 years of age from 8 representative kindergartens. Biometric measurements including axial length (AL), anterior chamber depth (ACD), and corneal radius of curvature (CR) were obtained from partial-coherence laser interferometry (IOL Master; Carl Zeiss Meditec, Oberkochen, Germany) before cycloplegia. Lens power (LP) and AL-to-CR ratio were calculated. Cycloplegic refraction (3 drops of 1% cyclopentolate) was measured using an autorefractor (KR8800; Topcon Corp., Tokyo, Japan), and spherical equivalent refraction (SER) was calculated. Biometric and refractive parameters were assessed as a function of age and gender. Multiple regression analysis was performed to explore the associations between refraction and ocular biometry. Ocular biometric distributions and their relationships to refraction. Among the 1127 children (99.5%) with successful cycloplegic refraction, mean SER was 1.37±0.63 diopters (D). Prevalence of myopia increased from 0% at 3 years of age to 3.7% (95% confidence interval, 1.0%-6.5%) at 6 years of age. Biometric parameters followed Gaussian distributions with means of 22.39±0.68 mm for AL, 7.79±0.25 mm for CR, and 24.61±1.42 D for calculated LP; and non-Gaussian distributions with means of 3.34±0.24 mm for ACD and 2.88±0.06 for AL-to-CR ratio. Axial length, ACD, and AL-to-CR ratio increased from 3 to 6 years of age, CR remained stable, whereas LP declined. Overall, SER declined slightly. For the SER variance, AL explained 18.6% and AL-to-CR ratio explained 39.8%, whereas AL, CR, and LP accounted for 80.0% after adjusting for age and gender. Young Chinese children are predominantly mildly hyperopic, with a low prevalence of myopia by the age of 6 years. An increase of 1 mm in AL was associated with only 0.45 D of myopic change. Decreases in LP reduce the myopic shifts that normally would be associated with increases in AL, and thus play a key role in refractive development in this age group. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Comparison of visual and refractive outcomes after bilateral implantation of toric intraocular lenses with or without a multifocal component.

    PubMed

    Hayashi, Ken; Masumoto, Miki; Takimoto, Minehiro

    2015-01-01

    To compare visual outcomes between patients with a multifocal toric intraocular lens (IOL) and those with a monofocal toric IOL. Hayashi Eye Hospital, Fukuoka, Japan. Prospective case-control series. Eyes with preoperative corneal astigmatism between 0.75 diopter (D) and 2.82 D scheduled for implantation of a diffractive multifocal toric IOL (Restor SND1T) or monofocal toric IOL (Acrysof SN6AT) were recruited. Three months postoperatively, visual acuity at various distances, contrast visual acuity, and refractive outcomes were examined. Each group comprised 66 eyes (33 patients). Postoperatively, the mean refractive astigmatism decreased to 0.71 D in the multifocal group and 0.74 D in the monofocal group. The mean monocular and binocular uncorrected and corrected near visual acuity at 0.3 m and intermediate visual acuity at 0.5 m were significantly better in the multifocal group than in the monofocal group (P≤.0011). The uncorrected and corrected visual acuities at other distances were similar between groups except at 1.0 m. Binocular photopic and mesopic contrast visual acuities at high to moderate contrasts did not differ significantly between groups; however, acuities at low contrasts were worse in the multifocal group (P≤.0429). Diffractive multifocal toric IOL implantation decreased refractive astigmatism to an acceptable range in eyes with moderate corneal astigmatism and provided useful visual acuity (≥20/40) at any distance and significantly better near and intermediate visual acuity than a monofocal toric IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Photoprotection and photoreception of intraocular lenses under xenon and white LED illumination.

    PubMed

    Artigas, J M; Navea, A; García-Domene, M C; Artigas, C; Lanzagorta, A

    2016-05-01

    To analyze the photoprotection and phototransmission that various intraocular lenses (IOLs) provide under the illumination of a xenon (Xe) lamp and white LEDs (light emitting diode). The spectral transmission curves of six representative IOLs were measured using a Perkin-Elmer Lambda 35 UV/VIS spectrometer. Various filtering simulations were performed using a Xe lamp and white LEDs. The spectral emissions of these lamps were measured with an ILT-950 spectroradiometer. The IOLs analyzed primarily show transmission of nearly 100% in the visible spectrum. In the ultraviolet (UV) region, the filters incorporated in the various IOLs did not filter equally, and some of them let an appreciable amount of UV through. The Xe lamp presented a strong emission of ultraviolet A (UVA), and its emission under 300nm was not negligible. The white LED did not present an appreciable emission under 380nm. The cut-off wavelength of most filters is between 380 and 400nm (Physiol Hydriol60C(®), IOLTECH E4T(®), Alcon SA60AT(®), Alcon IQ SN60WF(®)), so that their UV protection is very effective. Nonetheless, the IOL OPHTEC Oculaid(®) contains a filter that, when a Xe lamp is used, lets through up to 20% for 350nm and up to 15% for 300nm, which at this point is ultraviolet B (UVB). The OPHTEC(®) Artisan IOL has a transmission peak below 300nm, which must be taken into account under Xe illumination. White LEDs do not emit energy below 380nm, so no special protection is required in the UV region. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens design.

    PubMed

    Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando

    2018-01-01

    To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP ® ) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof ® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820 ® ). YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 ( p =0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm ( p =0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm ( p =0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups ( p >0.05). YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant.

  19. New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism.

    PubMed

    Canovas, Carmen; Alarcon, Aixa; Rosén, Robert; Kasthurirangan, Sanjeev; Ma, Joseph J K; Koch, Douglas D; Piers, Patricia

    2018-02-01

    To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Abbott Medical Optics, Inc., Groningen, the Netherlands. Retrospective case report. In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon-estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism (P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against-the-rule, with-the-rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups (P < .001). The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. The effects of surgical factors on postoperative astigmatism in patients enrolled in the Infant Aphakia Treatment Study (IATS).

    PubMed

    Wall, Palak B; Lee, Jason A; Lynn, Michael J; Lambert, Scott R; Traboulsi, Elias I

    2014-10-01

    To evaluate the effect of surgical factors on postoperative astigmatism in infants undergoing cataract extraction with or without intraocular lens (IOL) implantation. The Infant Aphakia Treatment Study is a multicenter clinical trial in which 114 infants with unilateral congenital cataracts were randomized to undergo cataract extraction with IOL placement or contact lens aphakic correction. Surgical videos were reviewed with regard to incision type and location, whether the incision was extended, the number of sutures placed, and technique of closure. Corneal astigmatism was measured using a handheld keratometer prior to surgery and at 1 year of age. Corneal astigmatism decreased from a mean of 1.92 D at baseline to 1.62 D at age 1 year in the contact lens group but remained almost unchanged from 2.00 D to 2.09 D in the IOL group (P = 0.023). There was no statistical difference between the amount of corneal astigmatism with regard to incision type (P = 0.214) and no increase in astigmatism with extension of the incision to facilitate IOL placement (P = 0.849) at 1 year. The number of sutures and technique of closure did not influence the amount of astigmatism at 1 year. At the age of 1 year following cataract extraction in infants, contact lens correction and the lack of IOL placement are associated with a significant decrease in postoperative corneal astigmatism compared to IOL placement. No other surgical factors considered in this study had a statistically significant effect on corneal astigmatism. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  1. Phakic Intraocular Lens Implantation: Refractive Outcome and Safety in Patients with Anterior Chamber Depth between 2.8 and 3.0 versus ≥3.0 mm.

    PubMed

    Guerra, Marta G; Silva, Andreia M M; Marques, Sara H M; Melo, Sofia H; Póvoa, João A; Lobo, Conceição; Murta, Joaquim Neto

    2017-01-01

    To compare endothelial cell (EC) variation after anterior chamber phakic intraocular lens (AC-pIOL) implantation in highly myopic patients with a preoperative anterior chamber depth (ACD) between 2.8 and 3.0 versus ≥3.0 mm. A total of 280 eyes submitted to primary AC-pIOL implantation were analyzed. Pre- and postoperative values for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, ACD (endothelial surface), and EC count were collected. The eyes were divided into 2 groups: group A - ACD between 2.8 and 3.0 mm; group B - ACD ≥3.0 mm. Mean global EC loss (ECL) and loss for each ACD group, according to pIOL type, were analyzed. Significant improvement of the spherical equivalent (-11.38 ± 4.57 vs. -0.49 ± 0.79; p = 0.000) and a significant decrease in EC density (2,810.95 ± 343.88 vs. 2,584.09 ± 374.88 cells/mm2; p = 0.000) were noted. The mean annual ECL was -2.19 ± 3.97%. Regarding group A (n = 80), a mean annual ECL of -2.06 ± 3.88% was registered, higher for the Acrysof Cachet® subtype, while group B (n = 200) showed -2.25 ± 4.01% ECL, higher for the Verisyse® subtype. There was no significant difference between the groups (p = 0.96). AC-pIOL implantation significantly improves the spherical equivalent in myopic patients. The mean annual ECL after pIOL implantation was higher in the larger ACD group, but this value was not statistically significant. A 2.8-mm ACD value seems to be a safe cutoff for AC-pIOL implantation. © 2017 S. Karger AG, Basel.

  2. Evaluation of the efficacy and safety of a standardised intracameral combination of mydriatics and anaesthetics for cataract surgery

    PubMed Central

    Labetoulle, Marc; Findl, Oliver; Malecaze, François; Alió, Jorge; Cochener, Béatrice; Lobo, Conceição; Lazreg, Sihem; Hartani, Dahbia; Colin, Joseph; Tassignon, Marie-José; Behndig, Anders

    2016-01-01

    Background/aims To compare the efficacy and safety of intracameral (IC) administration at the beginning of cataract surgery, of Mydrane, a standardised ophthalmic combination of tropicamide 0.02%, phenylephrine 0.31% and lidocaine 1%, to a standard topical regimen. Methods In this international phase III, prospective, randomised study, the selected eye of 555 patients undergoing phacoemulsification with intraocular lens (IOL) implantation received 200 μL of Mydrane (Mydrane group) just after the first incision or a topical regimen of one drop each of tropicamide 0.5% and phenylephrine 10% repeated three times (reference group). The primary efficacy variable was achievement of capsulorhexis without additional mydriatics. The non-inferiority of Mydrane to the topical regimen was tested. The main outcome measures were pupil size, patient perception of ocular discomfort and safety. Results Capsulorhexis without additional mydriatics was performed in 98.9% of patients and 94.7% in the Mydrane and reference groups, respectively. Both groups achieved adequate mydriasis (>7 mm) during capsulorhexis, phacoemulsification and IOL insertion. IOL insertion was classified as ‘routine’ in a statistically greater number of eyes in the Mydrane group compared with the reference group (p=0.047). Patients in the Mydrane group reported statistically greater comfort than the reference group before IOL insertion (p=0.034). Safety data were similar between groups. Conclusions Mydrane is an effective and safe alternative to standard eye drops for initiating and maintaining intraoperative mydriasis and analgesia. Patients who received IC Mydrane were significantly more comfortable before IOL insertion than the reference group. Surgeons found IOL insertion less technically challenging with IC Mydrane. Trial registration number NCT02101359; Results. PMID:26531052

  3. Preterm induction of labor: predictors of vaginal delivery and labor curves.

    PubMed

    Feghali, Maisa; Timofeev, Julia; Huang, Chun-Chih; Driggers, Rita; Miodovnik, Menachem; Landy, Helain J; Umans, Jason G

    2015-01-01

    The purpose of this study was to evaluate the labor curves of patients who undergo preterm induction of labor (IOL) and to assess possible predictors of vaginal delivery (VD). Data from the National Institute of Child Health and Human Development Consortium on Safe Labor were analyzed. A total of 6555 women who underwent medically indicated IOL at <37 weeks of gestation were included in this analysis. Patients were divided into 4 groups based on gestational age (GA): group A, 24-27+6 weeks; B, 28-30+6 weeks; C, 31-33+6 weeks; and D, 34-36+6 weeks. Pregnant women with a contraindication to VD, IOL ≥37 weeks of gestation, and without data from cervical examination on admission were excluded. Analysis of variance was used to assess differences between GA groups. Multiple logistic regression was used to assess predictors of VD. A repeated measures analysis was used to determine average labor curves. Rates of vaginal live births increased with GA, from 35% (group A) to 76% (group D). Parous women (odds ratio, 6.78; 95% confidence interval, 6.38-7.21) and those with a favorable cervix at the start of IOL (odds ratio, 2.35; 95% confidence interval, 2.23-2.48) were more likely to deliver vaginally. Analysis of labor curves in nulliparous women showed shorter duration of labor with increasing GA; the active phase of labor was, however, similar across all GAs. Most women who undergo medically indicated preterm IOL between 24 and 36+6 weeks of gestation deliver vaginally. The strongest predictor of VD was parity. Preterm IOL had a limited influence on estimated labor curves across GAs. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Term Elective Induction of Labor and Perinatal Outcomes in Obese Women: Retrospective Cohort Study

    PubMed Central

    Lee, Vanessa R.; Darney, Blair G.; Snowden, Jonathan M.; Main, Elliott K.; Gilbert, William; Chung, Judith; Caughey, Aaron B.

    2015-01-01

    Objective To compare perinatal outcomes between elective induction of labor (eIOL) and expectant management in obese women. Design Retrospective cohort study. Setting Deliveries in California in 2007. Population Term, singleton, vertex, nonanomalous deliveries among obese women (n=74,725). Methods Women who underwent eIOL at 37 weeks were compared with women who were expectantly managed at that gestational age. Similar comparisons were made at 38, 39, and 40 weeks. Results were stratified by parity. Chi-square tests and multivariable logistic regression were used for statistical comparison. Main Outcome Measures Method of delivery, severe perineal lacerations, postpartum hemorrhage, chorioamnionitis, macrosomia, shoulder dystocia, brachial plexus injury, respiratory distress syndrome. Results The odds of cesarean delivery were lower among nulliparous women with eIOL at 37 weeks (odds ratio [OR] 0.55, 95% confidence interval [CI] 0.34–0.90) and 39 weeks (OR 0.77, 95% CI 0.63–0.95) compared to expectant management. Among multiparous women with a prior vaginal delivery, eIOL at 37 (OR 0.39, 95% CI 0.24–0.64), 38 (OR 0.65, 95% CI 0.51–0.82), and 39 weeks (OR 0.67, 95% CI 0.56–0.81) was associated with lower odds of cesarean. Additionally, eIOL at 38, 39, and 40 weeks was associated with lower odds of macrosomia. There were no differences in the odds of operative vaginal delivery, lacerations, brachial plexus injury, or respiratory distress syndrome. Conclusions In obese women, term eIOL may decrease the risk of cesarean delivery, particularly in multiparas, without increasing the risks of other adverse outcomes when compared with expectant management. Tweetable Abstract Elective induction of labor in obese women does not increase risk of cesarean or other perinatal morbidities. PMID:26840780

  5. Term elective induction of labour and perinatal outcomes in obese women: retrospective cohort study.

    PubMed

    Lee, V R; Darney, B G; Snowden, J M; Main, E K; Gilbert, W; Chung, J; Caughey, A B

    2016-01-01

    To compare perinatal outcomes between elective induction of labour (eIOL) and expectant management in obese women. Retrospective cohort study. Deliveries in California in 2007. Term, singleton, vertex, nonanomalous deliveries among obese women (n = 74 725). Women who underwent eIOL at 37 weeks were compared with women who were expectantly managed at that gestational age. Similar comparisons were made at 38, 39, and 40 weeks. Results were stratified by parity. Chi-square tests and multivariable logistic regression were used for statistical comparison. Method of delivery, severe perineal lacerations, postpartum haemorrhage, chorioamnionitis, macrosomia, shoulder dystocia, brachial plexus injury, respiratory distress syndrome. The odds of caesarean delivery were lower among nulliparous women with eIOL at 37 weeks [odds ratio (OR) 0.55, 95% confidence interval (CI) 0.34-0.90] and 39 weeks (OR 0.77, 95% CI 0.63-0.95) compared to expectant management. Among multiparous women with a prior vaginal delivery, eIOL at 37 (OR 0.39, 95% CI 0.24-0.64), 38 (OR 0.65, 95% CI 0.51-0.82), and 39 weeks (OR 0.67, 95% CI 0.56-0.81) was associated with lower odds of caesarean. Additionally, eIOL at 38, 39, and 40 weeks was associated with lower odds of macrosomia. There were no differences in the odds of operative vaginal delivery, lacerations, brachial plexus injury or respiratory distress syndrome. In obese women, term eIOL may decrease the risk of caesarean delivery, particularly in multiparas, without increasing the risks of other adverse outcomes when compared with expectant management. © 2015 Royal College of Obstetricians and Gynaecologists.

  6. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    PubMed

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  7. Development of operationally stable inverted organic light-emitting diode prepared without using alkali metals (Presentation Recording)

    NASA Astrophysics Data System (ADS)

    Fukagawa, Hirohiko; Morii, Katsuyuki; Hasegawa, Munehiro; Gouda, Shun; Tsuzuki, Toshimitsu; Shimizu, Takahisa; Yamamoto, Toshihiro

    2015-10-01

    The OLED is one of the key devices for realizing future flexible displays and lightings. One of the biggest challenges left for the OLED fabricated on a flexible substrate is the improvement of its resistance to oxygen and moisture. A high barrier layer [a water vapor transmission rate (WVTR) of about 10-6 g/m2/day] is proposed to be necessary for the encapsulation of conventional OLEDs. Some flexible high barrier layers have recently been demonstrated; however, such high barrier layers require a complex process, which makes flexible OLEDs expensive. If an OLED is prepared without using air-sensitive materials such as alkali metals, no stringent encapsulation is necessary for such an OLED. In this presentation, we will discuss our continuing efforts to develop an inverted OLED (iOLED) prepared without using alkali metals. iOLEDs with a bottom cathode are considered to be effective for realizing air-stable OLEDs since the electron injection layer (EIL) can be prepared by fabrication processes that might damage the organic layers, resulting in the enhanced range of materials suitable for EILs. We have demonstrated that a highly efficient and relatively air-stable iOLED can be realized by employing poly(ethyleneimine) as an EIL. Dark spot formation was not observed after 250 days in the poly(ethyleneimine)-based iOLED encapsulated by a barrier film with a WVTR of 10-4 g/m2/day. In addition, we have demonstrated the fabrication of a highly operational stable iOLED utilizing a newly developed EIL. The iOLED exhibits an expected half-lifetime of over 10,000 h from an initial luminance of 1,000 cd/m2.

  8. Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support.

    PubMed

    Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P

    2016-02-01

    To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P < .01). Thirty-six eyes (97%) had an improved or unchanged CDVA, and 1 eye (3%) had a reduced CDVA because of worsening glaucoma. Postoperative complications included ocular hypertension (24%), iritis (5%), wound leakage (3%), transient corneal edema (3%), glaucoma requiring a tube shunt (3%), and IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens design

    PubMed Central

    Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando

    2018-01-01

    Purpose To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. Methods In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP®) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820®). Results YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 (p=0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm (p=0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm (p=0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups (p>0.05). Conclusion YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant. PMID:29593378

  10. [Development of ophthalmologic software for handheld devices].

    PubMed

    Grottone, Gustavo Teixeira; Pisa, Ivan Torres; Grottone, João Carlos; Debs, Fernando; Schor, Paulo

    2006-01-01

    The formulas for calculation of intraocular lenses have evolved since the first theoretical formulas by Fyodorov. Among the second generation formulas, the SRK-I formula has a simple calculation, taking into account a calculation that only involved anteroposterior length, IOL constant and average keratometry. With the evolution of those formulas, complexicity increased making the reconfiguration of parameters in special situations impracticable. In this way the production and development of software for such a purpose, can help surgeons to recalculate those values if needed. To idealize, develop and test a Brazilian software for calculation of IOL dioptric power for handheld computers. For the development and programming of software for calculation of IOL, we used PocketC program (OrbWorks Concentrated Software, USA). We compared the results collected from a gold-standard device (Ultrascan/Alcon Labs) with the simulation of 100 fictitious patients, using the same IOL parameters. The results were grouped for ULTRASCAN data and SOFTWARE data. Using SRK/T formula the range of those parameters included a keratometry varying between 35 and 55D, axial length between 20 and 28 mm, IOL constants of 118.7, 118.3 and 115.8. Using Wilcoxon test, it was shown that the groups do not differ (p=0.314). We had a variation in the Ultrascan sample between 11.82 and 27.97. In the tested program sample the variation was practically similar (11.83-27.98). The average of the Ultrascan group was 20.93. The software group had a similar average. The standard deviation of the samples was also similar (4.53). The precision of IOL software for handheld devices was similar to that of the standard devices using the SRK/T formula. The software worked properly, was steady without bugs in tested models of operational system.

  11. Visual outcomes after lensectomy and iris claw artisan intraocular lens implantation in patients with Marfan syndrome.

    PubMed

    Rabie, Hossein Mohammad; Malekifar, Parviz; Javadi, Mohammad Ali; Roshandel, Danial; Esfandiari, Hamed

    2017-08-01

    To review our experience with crystalline lens extraction and iris claw Artisan IOL implantation in patients with lens subluxation secondary to Marfan syndrome. A retrospective analysis of 12 eyes of 9 patients with lens subluxation due to Marfan syndrome who underwent crystalline lens removal and Artisan IOL (Ophtec, Groningen, Netherlands) implantation. A questionnaire of pre- and post-operative data, including demographics, pre- and postoperative comorbidities and complications was completed. Patients were evaluated for visual outcome and occurrence of complications. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalents (SE) were compared before and after lens extraction and IOL insertion. The mean age of the participants was 30.03 ± 15.02 years, and mean post-operative follow-up time was 44.5 ± 16.4 months. Mean BCVA also showed a significant improvement from 0.5 ± 0.3 at the baseline to 0.2 ± 0.2 post-operatively (P = 0.006). SE changed significantly from -11.38 ± 1.99 preoperatively to -0.45 ± 1.65 post-operatively (P = 0.003). All eyes had the IOL implanted at desired position. Post-operative complications were retinal detachment in one case and IOL dislocation in another patient. No other complication such as ocular hypertension, angle abnormalities, clinical cystoids macular edema, and corneal decompensation was observed during the follow-up period. Artisan IOL implantation after lens extraction appears to be an attractive alternative for optical correction in cases of Marfan syndrome with ectopia lentis. It confers a significant improvement in visual acuity with reasonable risk profile.

  12. Restoration of accommodation: surgical options for correction of presbyopia

    PubMed Central

    Glasser, Adrian

    2010-01-01

    Accommodation is a dioptric change in the power of the eye to see clearly at near. Ciliary muscle contraction causes a release in zonular tension at the lens equator, which permits the elastic capsule to mould the young lens into an accommodated form. Presbyopia, the gradual age-related loss of accommodation, occurs primarily through a gradual age-related stiffening of the lens. While there are many possible options for relieving the symptoms of presbyopia, only relatively recently has consideration been given to surgical restoration of accommodation to the presbyopic eye. To understand how this might be achieved, it is necessary to understand the accommodative anatomy, the mechanism of accommodation and the causes of presbyopia. A variety of different kinds of surgical procedures has been considered for restoring accommodation to the presbyopic eye, including surgical expansion of the sclera, using femtosecond lasers to treat the lens or with so-called accommodative intraocular lenses (IOLs). Evidence suggests that scleral expansion cannot and does not restore accommodation. Laser treatments of the lens are in their early infancy. Development and testing of accommodative IOLs are proliferating. They are designed to produce a myopic refractive change in the eye in response to ciliary muscle contraction either through a movement of an optic or through a change in surface curvature. Three general design principles are being considered. These are single optic IOLs that rely on a forward shift of the optic, dual optic IOLs that rely on an increased separation between the two optics, or IOLs that permit a change in surface curvature to produce an increase in optical power in response to ciliary muscle contraction. Several of these different IOLs are available and being used clinically, while many are still in research and development. PMID:18399800

  13. Histomorphological and immunofluorescence evaluation of clear corneal incisions after microcoaxial phacoemulsification with 2.2 mm and 1.8 mm systems.

    PubMed

    Vasavada, Abhay R; Johar, Kaid; Praveen, Mamidipudi R; Vasavada, Viraj A; Arora, Anshul I

    2013-04-01

    To compare changes in the incision's histomorphology and denaturation of collagen I in rabbit eyes having microcoaxial phacoemulsification through 2.2 mm and 1.8 mm incision-compatible systems. Randomized experimental trial. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. Thirty rabbit eyes were randomized into Group 1 (microcoaxial phacoemulsification through 2.2 mm incisions using Infiniti system [torsional ultrasound]) and Group 2 (microcoaxial phacoemulsification through 1.8 mm incisions using Stellaris system [longitudinal ultrasound]). Each group was then divided into 3 subgroups of 5 eyes each based on 1 of the 3 intervention options: phacoemulsification only, intraocular lens (IOL) insertion only, and phacoemulsification with IOL insertion. Left eyes were randomized for microcoaxial phacoemulsification, and right eyes were treated as controls. After phacoemulsification, eyes in Group 1 showed loss of epithelium at the roof of the incisions and Descemet membrane detachment at the floor of the incisions. These findings did not change after IOL insertion. After phacoemulsification, eyes in Group 2 showed loss of epithelium, but Descemet membrane remained attached. There was a longitudinal split in the incision's stroma in the direction of internal entry. The stromal damage increased after IOL implantation. Immunofluorescence studies showed no obvious irregularities in the arrangement of collagen I in either group. A dot blot analysis showed significant denaturation of collagen I in Group 2. The histomorphology of the 2.2 mm system incision showed localized Descemet membrane detachment and endothelial cell loss. The 1.8 mm system incision showed exaggerated stromal damage after IOL insertion. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. The use of a supplemental sulcus fixated IOL (HumanOptics Add-On IOL) to correct pseudophakic refractive errors.

    PubMed

    Basarir, Berna; Kaya, Vedat; Altan, Cigdem; Karakus, Sezen; Pinarci, Eylem Y; Demirok, Ahmet

    2012-01-01

    To evaluate the safety and efficacy of piggybacking with the HumanOptics Add-On intraocular lens (IOL) to correct pseudophakic refractive errors. Ten eyes of 10 patients with pseudophakic refractive errors were included in this study. All patients were targeted for a range of refraction -0.50 to +0.50 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), endothelial cell count (ECC), anterior chamber depth (ACD), the distance between intraocular lenses, and contrast sensitivity measurements under mesopic, scotopic, and scotopic with glare conditions were evaluated preoperatively and postoperatively. The mean age of the patients was 54±27 years (range 4-78). Mean follow-up time was 10.5±1.36 months (range 6-15 months). Mean diopters of implanted Add-On IOLs were -1.4±6.9 (range -12 to +9 D). Mean preoperative and postoperative UDVA was 0.133±0.12 and 0.73±0.27, respectively (p=0.0001); mean preoperative and postoperative CDVA were 0.77±0.26 and 0.79±0.27, respectively (p=0.066). Mean preoperative and postoperative ACD were 3.87±0.91 mm vs 3.58±1.05 mm, respectively (p=0.343); mean inter-IOL distance was 0.53±0.08 mm. Mean preoperative and postoperative ECC were 2455±302 and 2426±294, respectively (p=0.55). All patients were within the targeted refractive range of -0.50 D to +0.50 D. No complications were observed during the operations or postoperative follow-up period. Piggybacking with the Add-On IOL is a safe, efficient, and reliable technique to correct pseudophakic refractive errors.

  15. Use of intraocular lenses in cataract surgery in developing countries: memorandum from a WHO meeting.

    PubMed Central

    1991-01-01

    Visual loss or disability from cataract represents a massive public health and socioeconomic problem in most developing countries. At present, some 13.5 million cases require treatment and this number will increase, as most countries in the Third World are unable to cope with both the backlog and new cases. Cataract extraction with intraocular lens (IOL) implantation is now the established and preferred method in industrialized countries. The introduction of IOLs in developing countries, however, depends on their having adequately trained manpower and facilities (equipment and supplies, including IOLs) for surgery. This will inevitably increase the cost per operated case which, despite the scarce resources for cataract surgery in many developing countries, may be justified by the improved restoration of the patient's vision. Experience has led to the following generic designs for IOLs: the one-piece or three-piece C-loop polymethylmethacrylate (PMMA) posterior chamber lens, which is the current favourite; and, the flexible or rigid one-piece all-PMMA anterior chamber lens, which is a valid alternative in many situations. Further scientific evaluation of the use of these lenses in a wide variety of settings in developing countries is required. Operations research is also needed in order better to define and standardize the various steps and procedures in the surgical and post-operative management of IOL implantation in Third World settings. Meanwhile, the following should be available to ensure safe and good quality cataract surgery using IOLs in developing countries: properly trained surgeons; the needed facilities and equipment with regular supplies; a good quality lens of appropriate design; and the necessary means for careful follow-up of operated patients. PMID:1786616

  16. The effect of blue-blocking intraocular lenses on circadian biological rhythm: protocol for a randomised controlled trial (CLOCK-IOL colour study).

    PubMed

    Nishi, Tomo; Saeki, Keigo; Obayashi, Kenji; Miyata, Kimie; Tone, Nobuhiro; Tsujinaka, Hiroki; Yamashita, Mariko; Masuda, Naonori; Mizusawa, Yutarou; Okamoto, Masahiro; Hasegawa, Taiji; Maruoka, Shinji; Ueda, Tetsuo; Kojima, Masashi; Matsuura, Toyoaki; Kurumatani, Norio; Ogata, Nahoko

    2015-05-12

    Blue light information plays an important role in synchronising internal biological rhythm within the external environment. Circadian misalignment is associated with the increased risk of sleep disturbance, obesity, diabetes mellitus, depression, ischaemic heart disease, stroke and cancer. Meanwhile, blue light causes photochemical damage to the retina, and may be associated with age-related macular degeneration (AMD). At present, clear intraocular lenses (IOLs) and blue-blocking IOLs are both widely used for cataract surgery; there is currently a lack of randomised controlled trials to determine whether clear or blue-blocking IOLs should be used. This randomised controlled trial will recruit 1000 cataract patients and randomly allocate them to receive clear IOLs or blue-blocking IOLs in a ratio of 1:1. The primary outcomes are mortality and the incidence of cardiovascular disease, cancer and AMD. Secondary outcomes are fasting plasma glucose, triglycerides, cholesterol, glycated haemoglobin, sleep quality, daytime sleepiness depressive symptoms, light sensitivity, the circadian rhythm of physical activity, wrist skin temperature and urinary melatonin metabolite. Primary outcomes will be followed until 20 years after surgery, and secondary outcomes will be assessed at baseline and 1 year after surgery. Ethical approval has been obtained from the Institutional Review Board of Nara Medical University (No. 13-032). The findings of this study will be communicated to healthcare professionals, participants and the public through peer-reviewed publications, scientific conferences and the University Hospital Medical Information Network Clinical Trials Registry (UMIN-CTR) home page. UMIN000014680. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. AcrySof Natural SN60AT versus AcrySof SA60AT intraocular lens in patients with color vision defects.

    PubMed

    Raj, Shetal M; Vasavada, Abhay R; Nanavaty, Mayank A

    2005-12-01

    To determine whether implantation of the AcrySof Natural intraocular lens (IOL) worsened the severity of existing color deficit in congenital partial red-green color deficient individuals (CPRG). A prospective controlled randomized double-masked analysis of 30 consecutive patients with CPRG defect and bilateral cataracts received a Natural IOL (test group) in 1 eye and a single-piece AcrySof IOL (control group) in the other eye. Patients were tested unilaterally to detect CPRG defect using Ishihara pseudoisochromatic plates and the Farnsworth D-15 test. Plates 1 to 21 measured the Ishihara error score; plates 22 to 25 indicated severity of defect based on clarity of both numerals as partial mild/moderate (both visible), partial severe defect (only 1 visible). The D-15 test is based on number of diametrical crossings on the circular diagram; severity is graded as mild (1 crossing), moderate (2 crossings), or severe (>2 crossings). Tests were performed before and after IOL implantation at 1, 3, and 6 months. At mean follow-up of 6.13 months +/- 1.2 (SD), analysis of variance test judged the difference in error scores and cross tabulation represented change in number of diametrical crossings. The mean age was 62.3 +/- 8.5 years. All patients were men. Before IOL implantation, all patients had moderate CPRG defect on both tests. The Ishihara error score in the test and control groups did not reveal statistically significant differences (P = .505 and P = .119, respectively). With D-15, none of the patients in the test or control group showed >2 crossings. The implantation of AcrySof Natural IOL did not worsen the preexisting severity of color defect in CPRG individuals.

  18. Modelling lifetime cost consequences of ReSTOR® in cataract surgery in four European countries

    PubMed Central

    Lafuma, Antoine; Berdeaux, Gilles

    2008-01-01

    Background To compare the lifetime costs of liberating patients from spectacles after cataract surgery by implanting the multifocal intraocular lens (IOL) 'ReSTOR®' versus monofocal IOLs in France, Italy, Germany and Spain. Methods A Markov model was created to follow patient cohorts from cataract surgery until death. Prevalence rates of patients not needing spectacles after cataract surgery were obtained from clinical trials. Resource utilisation included implant surgery, IOLs, spectacles, visits to ophthalmologists and eye centres, transport, and time lost by patients. Economic perspectives were those of Society and Sickness Funds (SFs). Results The mean number of spectacles purchased after ReSTOR® was 1.34–1.61 and after monofocal IOLs 6.05–7.27. From the societal perspective, total cost estimates discounted by 3% were between €3,551 and €4,052 with ReSTOR® compared to €3,989 and €5,548 with monofocal IOLs. Undiscounted savings related to ReSTOR® ranged from €815 to €2,164. From the SFs' perspective total cost estimates discounted by 3% were between €2,150 and €2,524 with ReSTOR® compared to €2,324 and €2,610 with monofocal IOLs. Savings related to ReSTOR®, once costs discounted, ranged from €61 to €219. Discount and spectacle freedom prevalence rates were the most sensitive parameters. Conclusion The bulk of the savings related to ReSTOR® were realized outside the SF. From both a societal and SF perspective, savings, after a 3% discounting, achieved by liberating patients from spectacles counterbalanced the initially higher cost of ReSTOR®. ReSTOR® is a cost saving alternative to spectacles for patients requiring cataract surgery. PMID:18627594

  19. Evaluation of the efficacy and safety of a standardised intracameral combination of mydriatics and anaesthetics for cataract surgery.

    PubMed

    Labetoulle, Marc; Findl, Oliver; Malecaze, François; Alió, Jorge; Cochener, Béatrice; Lobo, Conceição; Lazreg, Sihem; Hartani, Dahbia; Colin, Joseph; Tassignon, Marie-José; Behndig, Anders

    2016-07-01

    To compare the efficacy and safety of intracameral (IC) administration at the beginning of cataract surgery, of Mydrane, a standardised ophthalmic combination of tropicamide 0.02%, phenylephrine 0.31% and lidocaine 1%, to a standard topical regimen. In this international phase III, prospective, randomised study, the selected eye of 555 patients undergoing phacoemulsification with intraocular lens (IOL) implantation received 200 μL of Mydrane (Mydrane group) just after the first incision or a topical regimen of one drop each of tropicamide 0.5% and phenylephrine 10% repeated three times (reference group). The primary efficacy variable was achievement of capsulorhexis without additional mydriatics. The non-inferiority of Mydrane to the topical regimen was tested. The main outcome measures were pupil size, patient perception of ocular discomfort and safety. Capsulorhexis without additional mydriatics was performed in 98.9% of patients and 94.7% in the Mydrane and reference groups, respectively. Both groups achieved adequate mydriasis (>7 mm) during capsulorhexis, phacoemulsification and IOL insertion. IOL insertion was classified as 'routine' in a statistically greater number of eyes in the Mydrane group compared with the reference group (p=0.047). Patients in the Mydrane group reported statistically greater comfort than the reference group before IOL insertion (p=0.034). Safety data were similar between groups. Mydrane is an effective and safe alternative to standard eye drops for initiating and maintaining intraoperative mydriasis and analgesia. Patients who received IC Mydrane were significantly more comfortable before IOL insertion than the reference group. Surgeons found IOL insertion less technically challenging with IC Mydrane. NCT02101359; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Comparative Efficacy of the New Optical Biometer on Intraocular Lens Power Calculation (AL-Scan versus IOLMaster).

    PubMed

    Ha, Ahnul; Wee, Won Ryang; Kim, Mee Kum

    2018-05-15

    To evaluate the agreement in axial length (AL), keratometry, and anterior chamber depth measurements between AL-Scan and IOLMaster biometers and to compare the efficacy of the AL-Scan on intraocular lens (IOL) power calculations and refractive outcomes with those obtained by the IOLMaster. Medical records of 48 eyes from 48 patients who underwent uneventful phacoemulsification and IOL insertion were retrospectively reviewed. One of the two types of monofocal aspheric IOLs were implanted (Tecnis ZCB00 [Tecnis, n = 34] or CT Asphina 509M [Asphina, n = 14]). Two different partial coherence interferometers measured and compared AL, keratometry (2.4 mm), anterior chamber depth, and IOL power calculations with SRK/T, Hoffer Q, Holladay2, and Haigis formulas. The difference between expected and actual final refractive error was compared as refractive mean error (ME), refractive mean absolute error (MAE), and median absolute error (MedAE). AL measured by the AL-Scan was shorter than that measured by the IOLMaster (p = 0.029). The IOL power of Tecnis did not differ between the four formulas; however, the Asphina measurement calculated using Hoffer Q for the AL-Scan was lower (0.28 diopters, p = 0.015) than that calculated by the IOLMaster. There were no statistically significant differences between the calculations by MAE and MedAE for the four formulas in either IOL. In SRK/T, ME in Tecnis-inserted eyes measured by AL-Scan showed a tendency toward myopia (p = 0.032). Measurement by AL-Scan provides reliable biometry data and power calculations compared to the IOLMaster; however, refractive outcomes of Tecnis-inserted eyes by AL-Scan calculated using SRK/T can show a slight myopic tendency. © 2018 The Korean Ophthalmological Society.

  1. Epidemiology and intermediate-term outcomes of open- and closed-globe injuries in traumatic childhood cataract.

    PubMed

    Khokhar, Sudarshan; Gupta, Shikha; Yogi, Rohit; Gogia, Varun; Agarwal, Tushar

    2014-01-01

    To study epidemiology and intermediate-term outcomes of open- and closed-globe injuries (CGI) in traumatic childhood cataract. In this retrospective interventional case series, demographic parameters and history including type of injury of 57 children younger than 16 years with traumatic cataract were recorded; ocular examination included best-corrected visual acuity (BCVA), slit-lamp biomicroscopy, and posterior segment evaluation. Patients underwent cataract surgery with or without intraocular lens (IOL) implantation. Main surgical outcomes at 6 months comprised BCVA, residual refractive spherical error (SE), and postoperative complications, namely visual axis opacification (VAO) and amblyopia. Bow and arrow was the most common causal agent. Open-globe injury (OGI) was 3 times more frequent than CGI. There was a significant visual gain from baseline in both groups after cataract surgery (p<0.001); residual SE was greater in OGI (1.6 ± 0.95 SD) compared to blunt trauma (0.8 ± 0.55 SD; p = 0.001). Incidence of corneal scarring, iris distortion, posterior synechiae, and intraoperative posterior capsular tear was greater with OGI (p<0.05). A total of 86% of patients were rehabilitated with a primary/secondary IOL. Single-piece IOL implantation rate (p = 0.004) was significantly greater in CGI, with no statistical difference for in-the-bag IOL (p = 0.053) and IOL implantation rate (p = 0.16). Final BCVA was significantly better for in-the-bag IOL implantation compared to sulcus fixation. Postoperative complications included amblyopia (51%) and VAO (12%). Bow and arrow injury caused the maximum cases of traumatic cataract; cataract extraction resulted in significant visual improvement; and CGI tended to have better prognosis in pediatric traumatic cataracts.

  2. Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis.

    PubMed

    2009-01-01

    The objective of this analysis is to review the effectiveness, safety, and cost-effectiveness of phakic intraocular lenses (pIOLs) for the treatment of myopia, hyperopia, and astigmatism. CONDITION AND TARGET POPULATION REFRACTIVE ERRORS: Refractive errors occur when the eye cannot focus light properly. In myopia (near- or short-sightedness), distant objects appear blurry because the axis of the eye is too long or the cornea is too steep, so light becomes focused in front of the retina. Hyperopia (far sightedness) occurs when light is focused behind the retina causing nearby objects to appear blurry. In astigmatism, blurred or distorted vision occurs when light is focused at two points rather than one due to an irregularly shaped cornea or lens. Refractive errors are common worldwide, but high refractive errors are less common. In the United States, the prevalence of high myopia (≤ -5 D) in people aged 20 to 39, 40 to 59, and 60 years and older is 7.4% (95% confidence interval [CI], 6.5% - 8.3%), 7.8% (95% CI, 6.4% - 8.6%), and 3.1% (95% CI, 2.2% - 3.9%), respectively. The prevalence of high hyperopia (≥ 3 D) is 1.0% (95% CI, .6% - 1.4%), 2.4% (95% CI, 1.7% - 3.0%), and 10.0% (95% CI, 9.1% - 10.9%) for the same age groupings. Finally, the prevalence of astigmatism (≥ 1 D cylinder) is 23.1% (95% CI, 21.6% - 24.5%), 27.6% (95% CI, 25.8% - 29.3%) and 50.1% (48.2% - 52.0%). LOW VISION: According to the Ontario Schedule of Benefits, low visual acuity is defined by a best spectacle corrected visual acuity (BSCVA) of 20/50 (6/15) or less in the better eye and not amenable to further medical and/or surgical treatment. Similarly, the Ontario Assistive Devices Program defines low vision as BSCVA in the better eye in the range of 20/70 or less that cannot be corrected medically, surgically, or with ordinary eyeglasses or contact lenses. Estimates of the prevalence of low vision vary. Using the criteria of BSCVA ranging from 20/70 to 20/160, one study estimated that 35.6 per 10,000 people in Canada have low vision. The 2001 Participation and Activity Limitation Survey (PALS) found that 594,350 (2.5%) Canadians had "difficulty seeing ordinary newsprint or clearly seeing the face of someone from 4 m," and the Canadian National Institute for the Blind (CNIB) registry classified 105,000 (.35%) Canadians as visually disabled. PHAKIC INTRAOCULAR LENSES (PIOL): A phakic intraocular lens (pIOL) is a supplementary lens that is inserted into the anterior or posterior chamber of the eye to correct refractive errors (myopia, hyperopia, and astigmatism). Unlike in cataract surgery, the eye's natural crystalline lens is not removed when the pIOL is inserted, so the eye retains its accommodative ability. In Canada and the United States, iris-fixated (anterior chamber lenses that are anchored to the iris with a claw) and posterior chamber lenses are the only types of pIOLs that are licensed by Health Canada and the Food and Drug Administration, respectively. EVIDENCE-BASED ANALYSIS METHOD: RESEARCH QUESTIONS #ENTITYSTARTX00026; What are the effectiveness, cost-effectiveness, and safety of pIOLs for the treatment of myopia, hyperopia, and astigmatism?Do certain subgroups (e.g. high myopia and low vision) benefit more from pIOLs?How do pIOLs compare with alternative surgical treatment options (LASIK, PRK, and CLE)?Using appropriate keywords, a literature search was conducted up to January 2009. Systematic reviews, meta-analyses, randomized controlled trials, and observational studies with more than 20 eyes receiving pIOLs were eligible for inclusion. The primary outcomes of interest were uncorrected visual acuity (UCVA), predictability of manifest refraction spherical equivalent (MRSE), and adverse events. The GRADE approach was used to systematically and explicitly evaluate the quality of evidence. The search identified 1,131 citations published between January 1, 2003, and January 16, 2009. Including a health technology assessment (HTA) identified in the bibliography review, 30 studies met the inclusion criteria: two HTAs; one systematic review; 20 pre-post observational studies; and seven comparative studies (five pIOL vs. LASIK, one pIOL vs. PRK, and one pIOL vs. CLE). Both HTAs concluded that there was good evidence of the short-term efficacy and safety of pIOLs, however, their conclusions regarding long-term safety differed. The 2006 HTA found convincing evidence of long-term safety, while the 2009 HTA found no long-term evidence about the risks of complications including cataract development, corneal damage, and retinal detachment. The systematic review of adverse events found that cataract development (incidence rate of 9.6% of eyes) is a substantial risk following posterior chamber pIOL implantation, while chronic endothelial cell loss is a safety concern after iris-fixated pIOL implantation. Adverse event rates varied by lens type, but they were more common in eyes that received posterior chamber pIOLs. The evidence of pIOL effectiveness is based on pre-post case series. These studies reported a variety of outcomes and different follow-up time points. It was difficult to combine the data into meaningful summary measures as many time points are based on a single study with a very small sample size. Overall, the efficacy evidence is low to very low quality based on the GRADE Working Group Criteria. For all refractive errors (low to high), most eyes experienced a substantial increase in uncorrected visual acuity (UCVA) with more than 75% of eyes achieving UCVA of 20/40 or better at all postoperative time points. The proportion of eyes that achieved postoperative UCVA 20/20 or better varied substantially according type of lens used and the type of refractive error being corrected, ranging from about 30% of eyes that received iris-fixated lenses for myopia to more than 78% of eyes that received posterior chamber toric lenses for myopic astigmatism. Predictability of manifest refraction spherical equivalent (MRSE) within ± 2.0 D was very high (≥ 90%) for all types of lenses and refractive error. At most time points, more than 50% of eyes achieved a MRSE within ± 0.5 D of emmetropia and at least 85% within ± 1.0 D. Predictability was lower for eyes with more severe preoperative refractive errors. The mean postoperative MRSE was less than 1.0 D in all but two studies. Safety, defined as a loss of two or more Snellen lines of best spectacle corrected visual acuity (BSCVA), was high for all refractive errors and lens types. Losses of two or more lines of BSCVA were uncommon, occurring in fewer than 2% of eyes that had received posterior chamber pIOLs for myopia, and less than 1% of eyes that received iris-fixated lens implantation for myopia. Most eyes did not experience a clinically significant change in BSCVA (i.e. loss of one line, no change, or gain of one line), but 10% to 20% of eyes gained two or more lines of BSCVA. The pIOL outcomes for UCVA, predictability, BSCVA, and adverse events were compared with FDA targets and safety values for refractive surgery and found to meet or exceed these targets at most follow-up time points. The results were then stratified to examine the efficacy of pIOLs for high refractive errors. There was limited data for many outcomes and time points, but overall the results were similar to those for all levels of refractive error severity. The studies that compared pIOLs with LASIK, PRK, and CLE for patients with moderate to high myopia and myopic astigmatism showed that pIOLs performed better than these alternative surgical options for the outcomes of: UCVA,predictability and stability of MRSE,postoperative MRSE,safety (measured as clinically significant loss of BSCVA), andgains in BSCVA.Correction of refractive cylinder (astigmatism) was the only outcome that favoured refractive surgery over pIOLs. This was observed for both toric and non-toric pIOLs (toric pIOLs correct for astigmatism, non-toric pIOLs do not). Common adverse events in the LASIK groups were diffuse lamellar keratitis and striae in the corneal flap. In the pIOL groups, lens repositioning and lens opacities (both asymptomatic and visually significant cataracts) were the most commonly observed adverse events. These studies were determined to be of low to very low evidence quality based on the GRADE Working Group Criteria. Eye, myopia, hyperopia, astigmatism, phakic intraocular lens, LASIK, PRK, uncorrected visual acuity, best corrected visual acuity, refractive errors, clear lens extraction.

  3. Management of corneal decompensation 4 decades after Sputnik intraocular lens implantation.

    PubMed

    Hirji, Nashila; Nanavaty, Mayank A

    2015-01-01

    We report an unusual case of corneal decompensation occurring four decades after complicated cataract extraction with implantation of a Sputnik intraocular lens (IOL) and highlight the clinical and practical issues faced in managing corneal decompensation with a Sputnik IOL. A 72-year-old woman presented with deterioration of the vision in her left eye, four decades after intracapsular cataract extraction with Sputnik IOL implantation. Ocular examination revealed diffuse corneal edema and thickened vitreous strands in the anterior chamber. Her best-corrected visual acuity (BCVA) worsened to 6/60 within 3 months. Anterior vitrectomy and inferior iridectomy combined with Desçemet-stripping automated endothelial keratoplasty was performed. The procedure was successful, with the patient achieving best-corrected visual acuity of 6/6 at 8 months postoperatively. Corneal decompensation after Sputnik IOL implantation can occur four decades later. When the historical preoperative visual acuity is good in such cases, careful anterior vitrectomy with Desçemet-stripping automated endothelial keratoplasty provides good visual rehabilitation.

  4. Intraocular Lens Use in an Astronaut During Long Duration Spaceflight.

    PubMed

    Mader, Thomas H; Gibson, C Robert; Schmid, Josef F; Lipsky, William; Sargsyan, Ashot E; Garcia, Kathleen; Williams, Jeffrey N

    2018-01-01

    The purpose of this paper is to report the first use of an intraocular lens (IOL) in an astronaut during long duration spaceflight (LDSF). An astronaut developed a unilateral cataract and underwent phacoemulsification with insertion of an acrylic IOL. Approximately 15 mo later he flew on a Soyuz spacecraft to the International Space Station (ISS), where he successfully completed a 6-mo mission. Ocular examination, including ultrasound (US), was performed before, during, and after his mission and he was questioned regarding visual changes during each portion of his flight. We documented no change in IOL position during his space mission. This astronaut reported excellent and stable vision during liftoff, entry into microgravity (MG), 6 mo on the ISS, descent, and landing. Our results suggest that modern IOLs are stable, effective, and well tolerated during LDSF.Mader TH, Gibson CR, Schmid JF, Lipsky W, Sargsyan AE, Garcia K, Williams JN. Intraocular lens use in an astronaut during long duration spaceflight. Aerosp Med Hum Perform. 2018; 89(1):63-65.

  5. Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery.

    PubMed

    Ong, Hon Shing; Evans, Jennifer R; Allan, Bruce D S

    2014-05-01

    Following cataract surgery and intraocular lens (IOL) implantation, loss of accommodation or postoperative presbyopia occurs and remains a challenge. Standard monofocal IOLs correct only distance vision; patients require spectacles for near vision. Accommodative IOLs have been designed to overcome loss of accommodation after cataract surgery. To define (a) the extent to which accommodative IOLs improve unaided near visual function, in comparison with monofocal IOLs; (b) the extent of compromise to unaided distance visual acuity; c) whether a higher rate of additional complications is associated the use of accommodative IOLs. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE in-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily Update, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 October 2013. We include randomised controlled trials (RCTs) which compared implantation of accommodative IOLs to implantation of monofocal IOLs in cataract surgery. Two authors independently screened search results, assessed risk of bias and extracted data. All included trials used the 1CU accommodative IOL (HumanOptics, Erlangen, Germany) for their intervention group. One trial had an additional arm with the AT-45 Crystalens accommodative IOL (Eyeonics Vision). We performed a separate analysis comparing 1CU and AT-45 IOL. We included four RCTs, including 229 participants (256 eyes), conducted in Germany, Italy and the UK. The age range of participants was 21 to 87 years. All studies included people who had bilateral cataracts with no pre-existing ocular pathologies. We judged all studies to be at high risk of performance bias. We graded two studies with high risk of detection bias and one study with high risk of selection bias.Participants who received the accommodative IOLs achieved better distance-corrected near visual acuity (DCNVA) at six months (mean difference (MD) -3.10 Jaeger units; 95% confidence intervals (CI) -3.36 to -2.83, 2 studies, 106 people, 136 eyes, moderate quality evidence). Better DCNVA was seen in the accommodative lens group at 12 to 18 months in the three trials that reported this time point but considerable heterogeneity of effect was seen, ranging from 1.3 (95% CI 0.98 to 1.68; 20 people, 40 eyes) to 6 (95% CI 4.15 to 7.85; 51 people, 51 eyes) Jaeger units and 0.12 (95% CI 0.05 to 0.19; 40 people, binocular) logMAR improvement (low quality evidence). The relative effect of the lenses on corrected distant visual acuity (CDVA) was less certain. At six months there was a standardised mean difference of -0.04 standard deviations (95% CI -0.37 to 0.30, 2 studies, 106 people, 136 eyes, low quality evidence). At long-term follow-up there was heterogeneity of effect with 18-month data in two studies showing that CDVA was better in the monofocal group (MD 0.12 logMAR; 95% CI 0.07 to 0.16, 2 studies, 70 people,100 eyes) and one study which reported data at 12 months finding similar CDVA in the two groups (-0.02 logMAR units, 95% CI -0.06 to 0.02, 51 people) (low quality evidence).The relative effect of the lenses on reading speed and spectacle independence was uncertain, The average reading speed was 11.6 words per minute more in the accommodative lens group but the 95% confidence intervals ranged from 12.2 words less to 35.4 words more (1 study, 40 people, low quality evidence). People with accommodative lenses were more likely to be spectacle-independent but the estimate was very uncertain (risk ratio (RR) 8.18; 95% CI 0.47 to 142.62, 1 study, 40 people, very low quality evidence).More cases of posterior capsule opacification (PCO) were seen in accommodative lenses but the effect of the lenses on PCO was uncertain (Peto odds ratio (OR) 2.12; 95% CI 0.45 to 10.02, 91 people, 2 studies, low quality evidence). People in the accommodative lens group were more likely to require laser capsulotomy (Peto OR 7.96; 95% CI 2.49 to 25.45, 2 studies, 60 people, 80 eyes, low quality evidence). Glare was reported less frequently with accommodative lenses but the relative effect of the lenses on glare was uncertain (RR any glare 0.78; 95% CI 0.32 to 1.90, 1 study, 40 people, and RR moderate/severe glare 0.45; 95% CI 0.04 to 4.60, low quality evidence). There is moderate-quality evidence that study participants who received accommodative IOLs had a small gain in near visual acuity after six months. There is some evidence that distance visual acuity with accommodative lenses may be worse after 12 months but due to low quality of evidence and heterogeneity of effect, the evidence for this is not clear-cut. People receiving accommodative lenses had more PCO which may be associated with poorer distance vision. However, the effect of the lenses on PCO was uncertain.Further research is required to improve the understanding of how accommodative IOLs may affect near visual function, and whether they provide any durable gains. Additional trials, with longer follow-up, comparing different accommodative IOLs, multifocal IOLs and monofocal IOLs, would help map out their relative efficacy, and associated late complications. Research is needed on control over capsular fibrosis postimplantation.Risks of bias, heterogeneity of outcome measures and study designs used, and the dominance of one design of accommodative lens in existing trials (the HumanOptics 1CU) mean that these results should be interpreted with caution. They may not be applicable to other accommodative IOL designs.

  6. Intraocular Lenses for the Treatment of Age-Related Cataracts

    PubMed Central

    2009-01-01

    Executive Summary Objective The objective of the report is to examine the comparative effectiveness and cost-effectiveness of various intraocular lenses (IOLs) for the treatment of age-related cataracts. Clinical Need: Target Population and Condition A cataract is a hardening and clouding of the normally transparent crystalline lens that may result in a progressive loss of vision depending on its size, location and density. The condition is typically bilateral, seriously compromises visual acuity and contrast sensitivity and increases glare. Cataracts can also affect people at any age, however, they usually occur as a part of the natural aging process. The occurrence of cataracts increases with age from about 12% at age 50 years, to 60% at age 70. In general, approximately 50% of people 65 year of age or older have cataracts. Mild cataracts can be treated with a change in prescription glasses, while more serious symptoms are treated by surgical removal of the cataract and implantation of an IOL. In Ontario, the estimated prevalence of cataracts increased from 697,000 in 1992 to 947,000 in 2004 (35.9% increase, 2.4% annual increase). The number of cataract surgeries per 1,000 individuals at risk of cataract increased from 64.6 in 1992 to 140.4 in 1997 (61.9% increase, 10.1% annual increase) and continued to steadily increase to 115.7 in 2004 (10.7% increase, 5.2% increase per year). Description of Technology/Therapy IOLs are classified either as monofocal, multifocal, or accommodative. Traditionally, monofocal (i.e.. fixed focusing power) IOLs are available as replacement lenses but their implantation can cause a loss of the eye’s accommodative capability (which allows variable focusing). Patients thus usually require eyeglasses after surgery for reading and near vision tasks. Multifocal IOLs aim to improve near and distant vision and obviate the need for glasses. Potential disadvantages include reduced contrast sensitivity, halos around lights and glare. Accommodating IOLs are designed to move with ciliary body contraction during accommodation and, therefore, offer a continuous range of vision (i.e. near, intermediate and distant vision) without the need for glasses. Purported advantages over multifocal IOLs include the avoidance of haloes and no reduction in contrast sensitivity. Polymethyl methacrylate (PMMA) was the first material used in the fabrication of IOLs and has inherent ultraviolet blocking abilities. PMMA IOLs are inflexible, however, and require a larger incision for implantation compared with newer foldable silicone (hydrophobic) and acrylic (hydrophobic or hydrophilic) lenses. IOLs can be further sub-classified as being either aspheric or spheric, blue/violet filtered or non-filtered or 1- or 3-piece. Methods of Evidence-Based Analysis A literature search was conducted from January 2003 to January 2009 that included OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), The Cochrane Library, and the International Agency for Health Technology Assessment/Centre for Review and Dissemination. Inclusion Criteria Exclusion Criteria adult patients with age-related cataractssystematic reviews, randomized controlled trials (RCTs)primary outcomes: distance visual acuity (best corrected distance visual acuity), near visual acuity (best distance corrected near visual acuity)secondary outcomes: contrast sensitivity, depth of field, glare, quality of life, visual function, spectacle dependence, posterior capsule opacification. studies with fewer than 20 eyesIOLs for non-age related cataractsIOLs for presbyopiastudies with a mean follow-up <6monthsstudies reporting insufficient data for analysis Comparisons of Interest The primary comparison of interest was accommodative vs. multifocal vs. monofocal lenses. Secondary comparisons of interest included: tinted vs. non-tinted lenses aspheric vs. spheric lenses multipiece vs. single piece lenses biomaterial A (e.g. acrylic) vs. biomaterial B (e.g. silicone) lenses sharp vs. round edged lenses The quality of the studies was examined according to the GRADE Working Group criteria for grading quality of evidence for interventional procedures. Summary of Findings The conclusions of the systematic review of IOLs for age-related cataracts are summarized in Executive Summary Table 1. Considerations for the Ontario Health System Procedures for crystalline lens removal and IOL insertion are insured and listed in the Ontario Schedule of Benefits. If a particular lens is determined to be medically necessary for a patient, the cost of the lens is covered by the hospital budget. If the patient chooses a lens that has enhanced features, then the hospital may choose to charge an additional amount above the cost of the usual lens offered. An IOL manufacturer stated that monofocal lenses comprise approximately 95% of IOL sales in Ontario and premium lenses (e.g., multifocal/accomodative) consist of about 5% of IOL sales. A medical consultant stated that all types of lenses are currently being used in Ontario (e.g., multifocal, monofocal, accommodative, tinted, nontinted, spheric, and aspheric). Nonfoldable lenses, rarely used in routine cases, are primarily used for complicated cataract implantation situations. ES Table 1: Conclusions for the Systematic Review of IOLs for Age-Related Cataracts Comparison Conclusion GRADE Quality Multifocal vs. monofocal Objective OutcomesSignificant improvement in BDCUNVANo significant difference in BCDVAInconclusive evidence for contrast sensitivityInconclusive evidence for glareSubjective OutcomesInconclusive evidence for visual satisfactionSignificant increase in glare/halosSignificant increase in freedom from spectacles moderatemoderatelowvery lowlowlow/moderatelow/moderate Accommodative vs. multifocal/monofocal Inconclusive due to Insufficient limited evidence for any effectiveness outcome very low Hydrophilic acrylic vs. other materials (hydrophobic acrylic, silicone) Significant increase in PCO score Low Sharp edged compared to round edged Significant reduction in PCO score Low One piece compared to three piece No significant difference in PCO score low Hydrophobic acrylic compared to silicone No significant difference in PCO score moderate Aspherical modified prolate anterior surface compared to spherical No significant difference in VASignificant reduction in contrast sensitivity very lowvery low Blue light filtering compared to non blue-light filtering No significant difference in BCDVANo significant difference in contrast sensitivityNo significant difference in HRQL lowlowhigh/moderate BCDVA refers to best corrected distance visual acuity; BDCUNVA, best distance corrected unaided near visual acuity; HRQL, health related quality of life; PCO, posterior capsule opacification; VA, visual acuity. PMID:23074519

  7. Influence of the effective lens position, as predicted by axial length and keratometry, on the near add power of multifocal intraocular lenses.

    PubMed

    Savini, Giacomo; Hoffer, Kenneth J; Lombardo, Marco; Serrao, Sebastiano; Schiano-Lomoriello, Domenico; Ducoli, Pietro

    2016-01-01

    To calculate the near focal distance of different multifocal intraocular lenses (IOLs) as a function of the 2 parameters that are measured before cataract surgery; that is, axial length (AL) and refractive corneal power (keratometry [K]). GB Bietti Foundation IRCCS, Rome, Italy. Noninterventional theoretical study. The IOL power for emmetropia was first calculated in an eye model with the AL ranging from 20 to 30 mm and K from 38 to 48 diopters (D). Then, the predicted myopic refraction for any given IOL add power (from +1.5 to +4.0 D) was calculated, and from this value the near focal distance was obtained. Calculations were also performed for the average eye (K = 43.81 D; AL = 23.65 mm). The near focal distance increased with increasing values of K and AL for each near power add. The near focal distance ranged between 53 cm and 72 cm (21 inches and 28 inches) for a multifocal IOL with +2.50 D, between 44 cm and 60 cm (17 inches and 24 inches) for a multifocal IOL with +3.00 D add, and between 33 cm and 44 cm (13 inches and 18 inches) for a multifocal IOL with +4.00 D add. In the average eye, the near focal distance ranges between 36 cm (near add power = 4.00 D) and 99 cm (near add power = 1.5 D). Longer eyes with steeper corneas showed the longest near focal distance and could experience more difficulties in focusing near objects after surgery. The opposite was true for short hyperopic eyes. Dr. Hoffer receives licensing fees for the commercial use of the registered trademark Hoffer from all biometry manufacturers using the Hoffer Q formula to ensure that it is programmed correctly and book royalties from Slack, Inc., for the textbook IOL Power. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial.

    PubMed

    Visser, Nienke; Beckers, Henny J M; Bauer, Noel J C; Gast, Sacha T J M; Zijlmans, Bart L M; Berenschot, Tos T J M; Webers, Carroll A; Nuijts, Rudy M M A

    2014-12-01

    Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism. A multicenter, hospital-based, randomized clinical trial was conducted. The participants included 86 individuals with bilateral cataract and bilateral corneal astigmatism of at least 1.25 diopters (D) who were randomized to receive either bilateral toric (n = 41) or bilateral control (n = 45) IOL implantation. Bilateral implantation of an aspherical toric IOL or an aspherical control IOL. Spectacle independency for distance vision, uncorrected distance visual acuity, refractive astigmatism, contrast sensitivity, wavefront aberrations, and refractive error-related quality-of-life questionnaire. Preoperatively, mean (SD) corneal astigmatism was 2.02 (0.95) D and 2.00 (0.84) D in the toric and control groups, respectively. Four patients (5%) were lost to follow-up. At 6 months postoperatively, 26 (70%) of the patients in the toric group achieved an uncorrected distance visual acuity of 20/25 or better compared with 14 (31%) in the control group (P < .001; odds ratio, 5.23; 95% CI, 2.03-13.48). Spectacle independency for distance vision was achieved in 31 patients (84%) in the toric group compared with 14 patients (31%) in the control group (P < .001; odds ratio, 11.44; 95% CI, 3.89- 33.63). Mean refractive astigmatism was -0.77 (0.52) D and -1.89 D (1.00) D, respectively. Vector analysis of toric IOLs showed a mean magnitude of error of +0.38 D, indicative of overcorrection. No significant differences were found in contrast sensitivity, higher-order aberrations, or refractive error-related quality of life. In patients with cataract and corneal astigmatism, bilateral toric IOL implantation results in a higher spectacle independency for distance vision compared with bilateral control IOL implantation. No significant differences were identified in contrast sensitivity, higher-order aberrations, or refractive error-related quality of life following both treatments. clinicaltrials.gov Identifier: NCT01075542.

  9. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

    PubMed Central

    Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai

    2016-01-01

    Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273

  10. Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.

    PubMed

    de Castro, Alberto; Rosales, Patricia; Marcos, Susana

    2007-03-01

    To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus), custom algorithms, and a custom-built Purkinje imaging apparatus. Twenty-five Scheimpflug images of the anterior segment of the eye were obtained at different meridians. Custom algorithms were used to process the images (correction of geometrical distortion, edge detection, and curve fittings). Intraocular lens tilt and decentration were estimated by fitting sinusoidal functions to the projections of the pupillary axis and IOL axis in each image. The Purkinje imaging system captures pupil images showing reflections of light from the anterior corneal surface and anterior and posterior lens surfaces. Custom algorithms were used to detect the Purkinje image locations and estimate IOL tilt and decentration based on a linear system equation and computer eye models with individual biometry. Both methods were validated with a physical model eye in which IOL tilt and decentration can be set nominally. Twenty-one eyes of 12 patients with IOLs were measured with both systems. Measurements of the physical model eye showed an absolute discrepancy between nominal and measured values of 0.279 degree (Purkinje) and 0.243 degree (Scheimpflug) for tilt and 0.094 mm (Purkinje) and 0.228 mm (Scheimpflug) for decentration. In patients, the mean tilt was less than 2.6 degrees and the mean decentration less than 0.4 mm. Both techniques showed mirror symmetry between right eyes and left eyes for tilt around the vertical axis and for decentration in the horizontal axis. Both systems showed high reproducibility. Validation experiments on physical model eyes showed slightly higher accuracy with the Purkinje method than the Scheimpflug imaging method. Horizontal measurements of patients with both techniques were highly correlated. The IOLs tended to be tilted and decentered nasally in most patients.

  11. Hydrophilic acrylic intraocular lens optic and haptics opacification in a diabetic patient: bilateral case report and clinicopathologic correlation.

    PubMed

    Pandey, Suresh K; Werner, Liliana; Apple, David J; Kaskaloglu, Mahmut

    2002-11-01

    To report clinicopathologic and ultrastructural features of two opacified single-piece hydrophilic acrylic intraocular lenses (IOLs) explanted from a diabetic patient. Interventional case report with clinicopathologic correlation. A 64-year-old white female underwent phacoemulsification and implantation of a single-piece hydrophilic acrylic lens (SC60B-OUV; Medical Developmental Research, Inc., Clear Water, FL) in October 1998 in the left eye and in July 1999 in the right eye. The best-corrected visual acuity after surgery was 20/60 in the left eye and 20/50 in the right eye. The patient had a marked decrease in visual acuity in June 2000 as a result of a milky, white opalescence of both lenses. Intraocular lens explantation and exchange was performed in both eyes and the explanted IOLs were submitted to our center for detailed pathologic, histochemical, and ultrastructural evaluation. They were stained with alizarin red and the von Kossa method for calcium, and also underwent scanning electron microscopy and energy dispersive radiograph spectroscopy to ascertain the nature of the deposits leading to opacification. Documentation of calcium deposits confirmed by histochemical stains and surface analyses. Opacification of the IOL was found to be the cause of decreased visual acuity. The opacification involved both the IOL optic and the haptics in the left eye and was confined to the IOL optic in the right eye. Histochemical and ultrastructural analyses revealed that the opacity was caused by deposition of calcium and phosphate within the lens optic and haptics. There are two features that distinguish this case from those reported earlier. This is the first clinicopathologic report of lens opacification that has involved completely the lens optic and the haptics. Second, these two explanted IOLs document the first bilateral case. This process of intraoptic and haptic opacification represents dystrophic calcification of unknown cause. Diabetic patients appear to be more severely and more often affected by lens opacification. Long-term follow-up of diabetic patients implanted with this IOL design should be maintained by surgeons and manufacturers.

  12. Isolation of a pH-Sensitive IgNAR Variable Domain from a Yeast-Displayed, Histidine-Doped Master Library.

    PubMed

    Könning, Doreen; Zielonka, Stefan; Sellmann, Carolin; Schröter, Christian; Grzeschik, Julius; Becker, Stefan; Kolmar, Harald

    2016-04-01

    In recent years, engineering of pH-sensitivity into antibodies as well as antibody-derived fragments has become more and more attractive for biomedical and biotechnological applications. Herein, we report the isolation of the first pH-sensitive IgNAR variable domain (vNAR), which was isolated from a yeast-displayed, semi-synthetic master library. This strategy enables the direct identification of pH-dependent binders from a histidine-enriched CDR3 library. Displayed vNAR variants contained two histidine substitutions on average at random positions in their 12-residue CDR3 loop. Upon screening of seven rounds against the proof-of-concept target EpCAM (selection for binding at pH 7.4 and decreased binding at pH 6.0), a single clone was obtained that showed specific and pH-dependent binding as characterized by yeast surface display and biolayer interferometry. Potential applications for such pH-dependent vNAR domains include their employment in tailored affinity chromatography, enabling mild elution protocols. Moreover, utilizing a master library for the isolation of pH-sensitive vNAR variants may be a generic strategy to obtain binding entities with prescribed characteristics for applications in biotechnology, diagnostics, and therapy.

  13. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    PubMed

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  14. Real-time Optical Coherence Tomography Incorporated in the Operating Microscope during Cataract Surgery.

    PubMed

    Almutlak, Mohammed A; Aloniazan, Turki; May, William

    2017-01-01

    A 55-year-old male presented with reduced vision due to senile cataract. The patient consented to undergo real-time intraoperative anterior segment-optical coherence tomography (AS-OCT) during phacoemulsification with intraocular lens (IOL) implantation. Images were captured at various points during the surgery. The use of AS-OCT incorporated into the surgical microscope was evaluated as an adjunct to cataract surgery. We were able to successfully evaluate, in real-time, wound architecture, the attachment of Descemet's membrane, the posterior capsule, and IOL position. Real-time AS-OCT can be used to proactively address potential complications and verify IOL placement intraoperatively.

  15. Bilateral cataract extraction with posterior chamber intraocular lens implantation simultaneous in pediatric cataracts.

    PubMed

    Caça, Ihsan; Sakalar, Yildirim Bayezit; Ari, Seyhmus; Alakus, Fuat; Dogan, Eyüp

    2008-01-01

    We evaluated the results of simultaneous bilateral cataract extraction with intraocular lens (IOL) inplantation 32 pediatric cataract patients. Simultaneous cataract extraction and posterior capsulotomy with anterior vitrectomy and IOL implantation is an effective and safe procedure in bilateral pediatric cataracts treatment.

  16. [Comparison of four MICS intraocular lenses regarding their rates of neodymium:YAG laser capsulotomy].

    PubMed

    Spyridaki, M; Höh, H

    2010-03-01

    The aim of this study was to evaluate the incidence of posterior capsule opacification up to 50 months following 1.7-mm bimanual MICS-cataract surgery. Bimanual MICS cataract surgery was performed in 197 eyes (135 patients) via two 1.7-mm corneal incisions. Four MICS acrylic foldable IOLs were implanted: AcriSmart 48S-5, n = 54 (Acritec GmbH, Hennigsdorf, now AT.Smart 48S Carl-Zeiss-Meditec, AG, Jena, Germany), ThinLens UltraChoice 1.0, n = 53 (Technomed GmbH, Baesweiler, Germany), AcriFlex 46, n = 41 und AcriFlex 48 CSE, n = 7 (Acrimed GmbH, Berlin, now: Lentis L-303, Oculentis GmbH, Berlin, Germany) and CareFlex, n = 43 (w2o Medizintechnik AG, Bruchsal, Germany). Statistical analysis was performed using the Kaplan-Meier technique. High levels of completeness of follow-up rates were: ThinLens 96%, CareFlex 100%, AcriSmart 93%, AcriFlex 92%. The capsulotomy rate was 43.13% for ThinLens within a mean/max. follow-up period of 801/1131 days, 34.88% for CareFlex (565/872 days), 40% for AcriSmart (988/1506 days) and 15.91% for AcriFlex (728/975 days). By limiting the follow-up period to a comparable maximum of 850 days for all four IOLs, our capsulotomy rates were as follows: ThinLens 33.33%, CareFlex 32.56 %, AcriSmart 20.0% and AcriFlex 11.36%. MICS IOLs have higher capsulotomy rates than hydrophobic acrylic lenses and sharp-edged silicone lenses. In literature comparisons MICS-IOLs do not exceed the variance levels of capsulotomy rates of PMMA, hydrophilic acrylic and silicone lenses without sharp edges. Cases of decentration or luxation of MICS-IOLs following Neodym:YAG laser capsulotomy were not detected. Capsulotomy frequency with the CareFlex was statistically significantly higher in comparison to the AcriSmart (Log Rank Mantel Cox Test, p = 0.007) and AcriFlex (log rank Mantel Cox test, p = 0.002). Capsulotomy rates observed varied for the four MICS-IOL-types tested. The posterior capsule opacification frequency of the two best MICS-IOLs (AcriFlex, AcriSmart) did not exceed the higher variance levels of posterior capsule opacification rates of the round-edged "conventional" non-MICS IOLs of PMMA, silicone or hydrophilic acryl material. Sharp-edged silicone or hydrophobic acrylic "conventional" lenses have shown lower posterior capsule opacification rates. Georg Thieme Verlag KG Stuttgart, New York.

  17. New light for old eyes: comparing melanopsin-mediated non-visual benefits of blue-light and UV-blocking intraocular lenses.

    PubMed

    Schmoll, Conrad; Khan, Ashraf; Aspinall, Peter; Goudie, Colin; Koay, Peter; Tendo, Christelle; Cameron, James; Roe, Jenny; Deary, Ian; Dhillon, Bal

    2014-01-01

    Melanopsin-expressing photosensitive retinal ganglion cells form a blue-light-sensitive non-visual system mediating diverse physiological effects including circadian entrainment and cognitive alertness. Reduced blue wavelength retinal illumination through cataract formation is thought to blunt these responses while cataract surgery and intraocular lens (IOL) implantation have been shown to have beneficial effects on sleep and cognition. We aimed to use the reaction time (RT) task and the Epworth Sleepiness Score (ESS) as a validated objective platform to compare non-visual benefits of UV- and blue-blocking IOLs. Patients were prospectively randomised to receive either a UV- or blue-blocking IOL, performing an RT test and ESS questionnaire before and after surgery. Optical blurring at the second test controlled for visual improvement. Non-operative age-matched controls were recruited for comparison. 80 participants completed the study. Those undergoing first-eye phacoemulsification demonstrated significant improvements in RT over control (p=0.001) and second-eye surgery patients (p=0.03). Moreover, reduced daytime sleepiness was measured by ESS for the first-eye surgery group (p=0.008) but not for the second-eye group (p=0.09). Choice of UV- or blue-blocking IOL made no significant difference to magnitude of cognitive improvement (p=0.272). Phacoemulsification, particularly first-eye surgery, has a strong positive effect on cognition and daytime alertness, regardless of IOL type.

  18. Clinical magnification and residual refraction after implantation of a double intraocular lens system in patients with macular degeneration.

    PubMed

    Amselem, Luis; Diaz-Llopis, Manuel; Felipe, Adelina; Artigas, Jose M; Navea, Amparo; García-Delpech, Salvador

    2008-09-01

    To evaluate the efficacy of a standard double intraocular lens (IOL) system (IOL-Vip) in patients with low vision and central scotoma due to macular degeneration and assess the predictability of the residual refraction and magnification. Ophthalmology Department, Hospital General Universitario, Valencia, Spain. This interventional prospective noncomparative case series comprised 13 consecutive surgical procedures in 10 patients with central scotoma. Follow-up was 12 months. Evaluation included the difference between preoperative and postoperative best corrected visual acuity (BCVA), refraction, position of the IOLs, endothelial cell density, and occurrence of postoperative complications. Residual refraction and eye magnification were calculated using a theory developed in a previous study, and the values were compared with the clinical results. The mean BCVA was 1.37 logMAR preoperatively and 0.68 logMAR 1 year postoperatively. The mean best corrected clinical gain was 44%. There was no statistically significant difference between the clinically evaluated and theoretically calculated residual refractions (P = .17). No intraoperative or postoperative complications occurred. Implantation of the double IOL system improved BCVA in patients with low vision due to advanced maculopathy. The results were best in myopic patients (long eyes); patients with hyperopia (short eyes) had high residual refraction. The postoperative clinical gain and residual refraction were predictable, showing the feasibility of implanting a customized double IOL.

  19. Clinical governance in the management of induction of labour.

    PubMed

    Zuberi, Nadeem Faiyaz; Siddiqui, Salva; Qureshi, Rahat Najam

    2003-02-01

    To determine whether dissemination of explicit guidelines, developed in consensus with stakeholders, for the processes of induction of labour (IOL), results in reduction of variability in clinical practice. A prospective behaviour modification interventional study. The study was conducted in the department of Obstetrics and Gynaecology at the Aga Khan University, Karachi, between January 1 and August 31, 2002. In a total of 142 conveniently sampled women, undergoing IOL, pre-identified quality assessment indicators were measured. After collection of data from initial 71-women (pre-intervention group) mutually agreed guidelines for clinical practice were disseminated, over a period of time, among consultants, residents and nurses. These indicators were again measured in subsequent 71 women (post-intervention group) to evaluate magnitude of residual non-conformities in these processes. Following behaviour modification interventions, nonconformities in consultants and residents-dependent processes like timely review of patients by consultants (72 vs 1.4%, p value <0.0001), documentation of indication for IOL (66.2 vs 16.9%, p value <0.0001), method of induction for IOL (56.3 vs 28.2%, p value 0.0001), and calculation of Bishop score before IOL (38.0 vs 4.2 %, p value <0.0001) were significantly reduced. Dissemination of explicit guidelines developed in consensus with stakeholders significantly reduces variability in clinical practice. Our model can be used for improving quality of care in other areas of obstetric health care.

  20. Pupil Influence on the Visual Outcomes of a New-Generation Multifocal Toric Intraocular Lens With a Surface-Embedded Near Segment.

    PubMed

    Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru

    2016-02-01

    To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P < .05). Statistically significant correlations were present between preoperative pupil diameters and postoperative visual acuities (Rs > 0; P < .05). Patients with a larger pupil always have better postoperative visual acuities. Meanwhile, there was no statistically significant correlation between pupil decentration and visual acuities (P > .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.

  1. Modern cataract surgery: unfinished business and unanswered questions.

    PubMed

    Apple, David J; Escobar-Gomez, Marcela; Zaugg, Brian; Kleinmann, Guy; Borkenstein, Andreas F

    2011-01-01

    We summarize information, based on clinicopathologic studies over the past decade, on various cataract intraocular lens (IOL) procedures and modern "specialized" IOLs, that will help surgeons continuously improve long-term results for cataract patients. Although most operations do initially provide excellent refractive correction and visual rehabilitation, late complications occur. These sometimes are missed because they are outside of the routine period of follow-up care. We have tried to determine if the various techniques and IOLs truly deliver the long-term results that we desire. Most safety and efficacy information is derived from the manufacturer and is passed through the U.S. Food and Drug Administration (FDA). This is often based on limited, relatively short-term observations made by the manufacturer. After a lens receives FDA approval, there are few means to assess the outcome of each procedure and lens years later. We rarely hear of a 10- or 20-year follow-up study. We have found that one of the best means to assess long-term results is pathologic analyses. We discuss recently studied aspects of pathologic reactions, such as posterior capsule opacification, intracapsular fibrosis, glistenings, intralenticular opacification, and other issues with the various IOL platforms; we then present a clinicopathological overview of tissues and IOLs from our database. These include hydrophobic and hydrophilic acrylic designs, plate lenses, and a dual optic lens. Copyright © 2011. Published by Elsevier Inc.

  2. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    PubMed

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  3. Glue-assisted intrascleral fixation of posterior chamber intraocular lens

    PubMed Central

    Narang, Priya; Narang, Samir

    2013-01-01

    Purpose: To analyze the visual outcome of patients undergoing glue-assisted intrascleral fixation of posterior chamber intraocular lens (IOL) in the absence of posterior capsular support. Materials and Methods: This retrospective study analyzes 25 eyes which underwent IOL implantation by the glued intrascleral fixation technique. The pre and post-operative uncorrected visual acuity (UCVA), pre and post-operative best corrected visual acuity (BCVA), intraocular pressure (IOP), IOL position, anterior chamber reaction and central macular thickness were assessed and recorded. Immediate and late post-operative complications were also recorded. Results: A total of 25 eyes of 22 patients were reviewed and analyzed over a period of one year. All eyes had a foldable three-piece IOL implanted. About 84% of the eyes had a gain of one or more lines, 12% had no gain, and 4% had a fall of three lines of BCVA on Snellen's visual chart, which was attributed to cystoid macular edema (CME). Postoperatively, there was a significant improvement in the UCVA (P < 0.05) and in the BCVA (P < 0.05). Postoperative complications included decentration in one case and vitritis with chronic macular edema in another case. Optical coherence tomography (OCT) demonstrated well placed IOL with no tilt. Conclusion: Although the results of one year follow-up of glued intrascleral fixation are promising, long term studies are recommended. PMID:23685487

  4. Evaluation of paraxial forward scattering from intraocular lens with increased surface light scattering using goniophotometry and Hartmann-Shack wavefront aberrometry.

    PubMed

    Minami, Keiichiro; Maruyama, Yoko; Mihashi, Toshifumi; Miyata, Kazunori; Oshika, Tetsuro

    2017-03-01

    To evaluate the influence of increases in light scattering on intraocular lens (IOL) surfaces on paraxial forward scattering using goniophotometry and Hartmann-Shack wavefront aberrometry. Surface light scattering was reproduced experimentally by acceleratedly aging 4 intraocular lenses by 0, 3, 5, and 10 years each. Light scattering from both IOL surfaces was measured using Scheimpflug photography. The paraxial forward scattering from the aged IOLs was measured using a goniophotometer with a halogen light source (wavelength: 350-850 nm) and telecentric optics, and changes in the maximum intensity and full width at 10% of maximum intensity (FW10%) were evaluated. The influences on the retina image were examined using a Hartmann-Shack aberrometer (wavelength: 840 nm). The contrast and difference from the point spread function of the central centroids were evaluated. The mean surface light scattering from both IOL surfaces ranged from 30.0 to 118.3 computer compatible tape (CCT) and increased with each aging year. Evaluations using the goniophotometer and the Hartmann-Shack aberrometer showed no significant change in the paraxial forward scattering with the aging year (P > .45, Kruskal-Wallis test), and no association with the surface light scattering intensity was found (P > .75, Spearman rank correlation). This experimental study using aged IOLs demonstrated that surface light scattering does not influence paraxial forward scattering.

  5. A Digital Phase Lock Loop for an External Cavity Diode Laser

    NASA Astrophysics Data System (ADS)

    Wang, Xiao-Long; Tao, Tian-Jiong; Cheng, Bing; Wu, Bin; Xu, Yun-Fei; Wang, Zhao-Ying; Lin, Qiang

    2011-08-01

    A digital optical phase lock loop (OPLL) is implemented to synchronize the frequency and phase between two external cavity diode lasers (ECDL), generating Raman pulses for atom interferometry. The setup involves all-digital phase detection and a programmable digital proportional-integral-derivative (PID) loop in locking. The lock generates a narrow beat-note linewidth below 1 Hz and low phase-noise of 0.03rad2 between the master and slave ECDLs. The lock proves to be stable and robust, and all the locking parameters can be set and optimized on a computer interface with convenience, making the lock adaptable to various setups of laser systems.

  6. 42 CFR 414.108 - IOLs inserted in a physician's office.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 3 2014-10-01 2014-10-01 false IOLs inserted in a physician's office. 414.108 Section 414.108 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee...

  7. Resident and young physician experience with complex cataract surgery and new cataract and refractive technology: Results of the ASCRS 2016 Young Eye Surgeons survey.

    PubMed

    Schallhorn, Julie M; Ciralsky, Jessica B; Yeu, Elizabeth

    2017-05-01

    A survey was offered to attendees of the 2016 annual meeting of the American Society of Cataract and Refractive Surgery (ASCRS) as well as online to ASCRS members. Of the 429 self-identified surgeons in training or those with fewer than 5 years in practice, 83% had performed complex cataract surgery using iris expansion devices or capsular tension rings (63%) and 70% had implanted a toric intraocular lens (IOL). A minority of respondents had performed laser-assisted cataract surgery (27%) or implanted presbyopia-correcting IOLs (39%), and only half (50%) had performed laser vision correction (LVC). Comfort with complex cataract and IOL procedures improved with increasing number of cases performed until greater than 10 cases. From this we can conclude that young surgeons have adequate exposure to complex cataracts but lack experience in refractive surgery and new IOL technology. Reported surgeon confidence improved with increased experience and exposure. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

    PubMed

    Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M

    2013-11-01

    The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.

  9. Iron Overload and Chelation Therapy in Non-Transfusion Dependent Thalassemia.

    PubMed

    Bou-Fakhredin, Rayan; Bazarbachi, Abdul-Hamid; Chaya, Bachar; Sleiman, Joseph; Cappellini, Maria Domenica; Taher, Ali T

    2017-12-20

    Iron overload (IOL) due to increased intestinal iron absorption constitutes a major clinical problem in patients with non-transfusion-dependent thalassemia (NTDT), which is a cumulative process with advancing age. Current models for iron metabolism in patients with NTDT suggest that suppression of serum hepcidin leads to an increase in iron absorption and subsequent release of iron from the reticuloendothelial system, leading to depletion of macrophage iron, relatively low levels of serum ferritin, and liver iron loading. The consequences of IOL in patients with NTDT are multiple and multifactorial. Accurate and reliable methods of diagnosis and monitoring of body iron levels are essential, and the method of choice for measuring iron accumulation will depend on the patient's needs and on the available facilities. Iron chelation therapy (ICT) remains the backbone of NTDT management and is one of the most effective and practical ways of decreasing morbidity and mortality. The aim of this review is to describe the mechanism of IOL in NTDT, and the clinical complications that can develop as a result, in addition to the current and future therapeutic options available for the management of IOL in NTDT.

  10. Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations

    PubMed Central

    Akondi, Vyas; Dorronsoro, Carlos; Gambra, Enrique; Marcos, Susana

    2017-01-01

    Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed. PMID:28717577

  11. Pregnancy outcomes of induced labor in women with previous cesarean section: a systematic review and meta-analysis.

    PubMed

    Rossi, A C; Prefumo, Federico

    2015-02-01

    To systematically review the literature about maternal and neonatal outcomes following induction of labor (IOL) and spontaneous labor (SL) in women with previous cesarean section (PCS). PubMed, Medline, EMBASE, Cochrane library searches; January 2000-February 2013. women attempting labor after PCS, singleton term pregnancies. Women undergoing IOL were compared with women in SL. Method for induction, mode of delivery, uterine rupture/dehiscence, post-partum hemorrhage, emergency hysterectomy and any maternal or neonatal morbidity and mortality were analyzed. MOOSE guidelines were followed. Interstudies heterogeneity was tested. A random effect model was generated if heterogeneity was >25 %. Pooled odds ratio with 95 % confidence interval (OR, 95 % CI) were calculated. Eight articles included 4,038 women with IOL (23.2 %) and 13,374 women with SL (76.8 %). IOL was associated with a lower incidence of vaginal delivery (OR 0.66; 95 % CI 0.55-0.80) and higher rates of cesarean section (OR 1.52; 95 % CI 1.26-1.83), uterine rupture/dehiscence (OR 1.62; 95 % CI 1.13-2.31), and post-partum hemorrhage (OR 1.57; 95 % CI 1.20-2.04), although hysterectomy was similar between the two groups (OR 2.60; 95 % CI 0.52-13.1). Neonatal morbidity was similar after IOL or SL (OR 1.13; 95 % CI 0.75-1.69). Induction of labor increases the risk of uterine rupture/dehiscence and of repeat cesarean section.

  12. Effect of Myopic Defocus on Visual Acuity after Phakic Intraocular Lens Implantation and Wavefront-guided Laser in Situ Keratomileusis

    PubMed Central

    Kamiya, Kazutaka; Shimizu, Kimiya; Igarashi, Akihito; Kawamorita, Takushi

    2015-01-01

    This study aimed to investigate the effect of myopic defocus on visual acuity after phakic intraocular lens (IOL) implantation and wavefront-guided laser in situ keratomileusis (wfg-LASIK). Our prospective study comprised thirty eyes undergoing posterior chamber phakic IOL implantation and 30 eyes undergoing wfg-LASIK. We randomly measured visual acuity under myopic defocus after cycloplegic and non-cycloplegic correction. We also calculated the modulation transfer function by optical simulation and estimated visual acuity from Campbell & Green’s retinal threshold curve. Visual acuity in the phakic IOL group was significantly better than that in the wfg-LASIK group at myopic defocus levels of 0, –1, and –2 D (p < 0.001, p < 0.001, and p = 0.02, Mann-Whitney U-test), but not at a defocus of –3 D (p = 0.30). Similar results were also obtained in a cycloplegic condition. Decimal visual acuity values at a myopic defocus of 0, −1, −2, and -3 D by optical simulation were estimated to be 1.95, 1.21, 0.97, and 0.75 in the phakic IOL group, and 1.39, 1.11, 0.94, and 0.71 in the wfg-LASIK group, respectively. From clinical and optical viewpoints, phakic IOL implantation was superior to wfg-LASIK in terms of the postoperative visual performance, even in the presence of low to moderate myopic regression. PMID:25994984

  13. Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens.

    PubMed

    Hayashi, Ken; Manabe, Shin-Ichi; Yoshida, Motoaki; Hayashi, Hideyuki

    2010-08-01

    To examine the effect of astigmatism on visual acuity at various distances in eyes with a diffractive multifocal intraocular lens (IOL). Hayashi Eye Hospital, Fukuoka, Japan. In this study, eyes had implantation of a diffractive multifocal IOL with a +3.00 diopter (D) addition (add) (AcrySof ReSTOR SN6AD1), a diffractive multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), or a monofocal IOL (AcrySof SN60WF). Astigmatism was simulated by adding cylindrical lenses of various diopters (0.00, 0.50, 1.00, 1.50, 2.00), after which distance-corrected acuity was measured at various distances. At most distances, the mean visual acuity in the multifocal IOL groups decreased in proportion to the added astigmatism. With astigmatism of 0.00 D and 0.50 D, distance-corrected near visual acuity (DCNVA) in the +4.00 D group and distance-corrected intermediate visual acuity (DCIVA) and DCNVA in the +3.00 D group were significantly better than in the monofocal group; the corrected distance visual acuity (CDVA) was similar. The DCNVA with astigmatism of 1.00 D was better in 2 multifocal groups; however, with astigmatism of 1.50 D and 2.00 D, the CDVA and DCIVA at 0.5m in the multifocal groups were significantly worse than in the monofocal group, although the DCNVA was similar. With astigmatism of 1.00 D or greater, the mean CDVA and DCNVA in the multifocal groups reached useful levels (20/40). The presence of astigmatism in eyes with a diffractive multifocal IOL compromised all distance visual acuities, suggesting the need to correct astigmatism of greater than 1.00 D. No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. In vivo chromatic aberration in eyes implanted with intraocular lenses.

    PubMed

    Pérez-Merino, Pablo; Dorronsoro, Carlos; Llorente, Lourdes; Durán, Sonia; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2013-04-12

    To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL). EIGHTEEN EYES PARTICIPATED IN THIS STUDY: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-developed laser ray tracing (LRT) aberrometer was used to measure the optical aberrations, at 532 nm and 785 nm wavelengths. The monochromatic wave aberrations were described using a fifth-order Zernike polynomial expansion. The chromatic difference of focus was estimated as the difference between the equivalent spherical errors corresponding to each wavelength. Wave aberration measurements were highly reproducible. Except for the defocus term, no significant differences in high order aberrations (HOA) were found between wavelengths. The average chromatic difference of focus was 0.46 ± 0.15 diopters (D) in the Tecnis group, and 0.75 ± 0.12 D in the AcrySof group, and the difference was statistically significant (P < 0.05). Chromatic difference of focus in the AcrySof group was not statistically significantly different from the Longitudinal chromatic aberration (LCA) previously reported in a phakic population (0.78 ± 0.16 D). The impact of LCA on retinal image quality (measured in terms of Strehl ratio) was drastically reduced when considering HOA and astigmatism in comparison with a diffraction-limited eye, yielding the differences in retinal image quality between Tecnis and AcrySof IOLs not significant. LRT aberrometry at different wavelengths is a reproducible technique to evaluate the chromatic difference of focus objectively in eyes implanted with IOLs. Replacement of the crystalline lens by the IOL did not increase chromatic difference of focus above that of phakic eyes in any of the groups. The AcrySof group showed chromatic difference of focus values very similar to physiological values in young eyes.

  15. UV solid state laser ablation of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Apostolopoulos, A.; Lagiou, D. P.; Evangelatos, Ch.; Spyratou, E.; Bacharis, C.; Makropoulou, M.; Serafetinides, A. A.

    2013-06-01

    Commercially available intraocular lenses (IOLs) are manufactured from silicone and acrylic, both rigid (e.g. PMMA) and foldable (hydrophobic or hydrophilic acrylic biomaterials), behaving different mechanical and optical properties. Recently, the use of apodizing technology to design new diffractive-refractive multifocals improved the refractive outcome of these intraocular lenses, providing good distant and near vision. There is also a major ongoing effort to refine laser refractive surgery to correct other defects besides conventional refractive errors. Using phakic IOLs to treat high myopia potentially provides better predictability and optical quality than corneal-based refractive surgery. The aim of this work was to investigate the effect of laser ablation on IOL surface shaping, by drilling circular arrays of holes, with a homemade motorized rotation stage, and scattered holes on the polymer surface. In material science, the most popular lasers used for polymer machining are the UV lasers, and, therefore, we tried in this work the 3rd and the 5th harmonic of a Q-switched Nd:YAG laser (λ=355 nm and λ=213 nm respectively). The morphology of the ablated IOL surface was examined with a scanning electron microscope (SEM, Fei - Innova Nanoscope) at various laser parameters. Quantitative measurements were performed with a contact profilometer (Dektak-150), in which a mechanical stylus scanned across the surface of gold-coated IOLs (after SEM imaging) to measure variations in surface height and, finally, the ablation rates were also mathematically simulated for depicting the possible laser ablation mechanism(s). The experimental results and the theoretical modelling of UV laser interaction with polymeric IOLs are discussed in relation with the physical (optical, mechanical and thermal) properties of the material, in addition to laser radiation parameters (laser energy fluence, number of pulses). The qualitative aspects of laser ablation at λ=213 nm reveal a smooth optical surface on the intraocular lens with no irregularities, observed with other wavelengths.

  16. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography

    PubMed Central

    Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    Purpose To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). Methods A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. Results The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). Conclusion When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4–6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability. PMID:28863141

  17. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

    PubMed

    Kimura, Shuhei; Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4-6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.

  18. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace

    PubMed Central

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    PURPOSE: The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. SETTING/VENUE: Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. PATIENTS AND METHODS: Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. RESULTS: Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant (P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° (P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° (P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. CONCLUSIONS: Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag. PMID:28757694

  19. Analysis of patients with good uncorrected distance and near vision after monofocal intraocular lens implantation.

    PubMed

    Nanavaty, Mayank A; Vasavada, Abhay R; Patel, Anil S; Raj, Shetal M; Desai, Tejas H

    2006-07-01

    To analyze factors contributing to uncorrected visual acuity of at least 6/12 for distance and at least J4 for near (pseudoaccommodation) after monofocal intraocular lens (IOL) implantation. Iladevi Cataract and IOL Research Center, Ahmedabad, India. In a case-controlled study of 30 eyes (30 patients) that had phacoemulsification, those with pseudoaccommodation were assigned to cases and 30 eyes (30 patients) without pseudoaccommodation were designated as controls. Controls were matched by identical best corrected visual acuity, age, and postoperative duration. Subjective refraction was done with retinoscopy. Factors analyzed included corneal astigmatism, pupil size, axial IOL movement, amplitude of accommodation, axial length (AL), and age. Corneal astigmatism was noted on topography and interpreted as against the rule (ATR) (180 +/- 15 degrees), with the rule (WTR) (90 +/- 15 degrees), and oblique (OB) (45/135 +/- 30 degrees). Pupil size was noted on topographic display and AL and anterior chamber depth (ACD) on immersion A-scan. The axial IOL movement was calculated as the difference in ACD after instillation of cyclopentolate 1% (Cyclopent) and subsequently pilocarpine nitrate 2% (Carpinol) at separate visits, and amplitude of accommodation was measured with static and dynamic retinoscopy. Multivariate logistic regression and odds ratio with 95% confidence intervals were determined. Mean spherical equivalent was -0.45 +/- 0.63 diopter (D) in cases and -0.35 +/- 0.83 D (P = .61) in controls. Multivariate logistic regression in cases versus controls: corneal astigmatism (ATR versus WTR and OB collectively): 10.19 [1.8,57.44], P = .009; pupil size: 0.45 [0.07,2.71], P = .38; axial IOL movement: 1.39 [0.51,0.77], P = .514; amplitude of accommodation: 2.95 [0.93,9.3], P = .065; AL: 0.55 [0.29,1.02], P = .058; and age: 0.98 [0.5,1.95], P = .963. The study suggests a significant role of ATR corneal astigmatism in good uncorrected distance and near vision after monofocal IOL implantation.

  20. Examining Wrong Eye Implant Adverse Events in the Veterans Health Administration With a Focus on Prevention: A Preliminary Report.

    PubMed

    Neily, Julia; Chomsky, Amy; Orcutt, James; Paull, Douglas E; Mills, Peter D; Gilbert, Christina; Hemphill, Robin R; Gunnar, William

    2018-03-01

    The study goals were to examine wrong intraocular lens (IOL) implant adverse events in the Veterans Health Administration (VHA), identify root causes and contributing factors, and describe system changes that have been implemented to address this challenge. This study represents collaboration between the VHA's National Center for Patient Safety (NCPS) and the National Surgery Office (NSO). This report includes 45 wrong IOL implant surgery adverse events reported to established VHA NCPS and NSO databases between July 1, 2006, and June 31, 2014. There are approximately 50,000 eye implant procedures performed each year in the VHA. Wrong IOL implant surgery adverse events are reported by VHA facilities to the NCPS and the NSO. Two authors (A.C. and J.N.) coded the reports for event type (wrong lens or expired lens) and identified the primary contributing factor (coefficient κ = 0.837). A descriptive analysis was conducted, which included the reported yearly event rate. The main outcome measure was the reported wrong IOL implant surgery adverse events. There were 45 reported wrong IOL implant surgery adverse events. Between 2011 and June 30, 2014, there was a significant downward trend (P = 0.02, R = 99.7%) at a pace of -0.08 (per 10,000 cases) every year. The most frequently coded primary contributing factor was incomplete preprocedure time-out (n = 12) followed by failure to perform double check of preprocedural calculations based upon original data and implant read-back at the time the surgical eye implant was performed (n = 10). Preventing wrong IOL implant adverse events requires diligence beyond performance of the preprocedural time-out. In 2013, the VHA has modified policy to ensure double check of preprocedural calculations and implant read-back with positive impact. Continued analysis of contributing human factors and improved surgical team communication are warranted.

  1. Comparison of clinical performance between trifocal and bifocal intraocular lenses: A meta-analysis.

    PubMed

    Xu, Zequan; Cao, Danmin; Chen, Xu; Wu, Song; Wang, Xin; Wu, Qiang

    2017-01-01

    To compare the clinical performance between trifocal and bifocal intraocular lenses in bilateral cataract and/or refractive lens exchange (RLE) surgery. A comprehensive literature search of PubMed, EMBASE, Cochrane Controlled Trials Register and Web of Science was performed through October 2016 to identify randomized, controlled trials (RCTs) and comparative cohort studies. The primary outcomes were uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), defocus curve, spectacle independence, patient satisfaction and contrast sensitivity. The secondary outcomes were residual sphere, spherical equivalent (SE), cylinder and complications. Six RCTs and 2 cohort studies including 568 eyes (278 in the trifocal group and 290 in the bifocal group) were identified. There was a statically significant difference between the two groups in UDVA (WMD: -0.03, 95% CI: -0.05 to -0.01, P = 0.005), but the difference (0.03 log MAR) is not clinically significant. Intermediate visual acuity was better in the trifocal IOL group judging from UIVA and defocus curves. There was a statically significant difference between the two groups in residual cylinder (WMD: 0.11, 95% CI: 0.02 to 0.20, P = 0.02), and subgroup AT Lisa tri 839MP trifocal also showed significant better UNVA than bifocal IOLs (WMD: -0.13, 95% CI: -0.17 to -0.08, P<0.00001). However, no significant differences were observed in UNVA (WMD: -0.04, 95% CI: -0.11 to 0.02, P = 0.19), spectacle independence (WMD: 1.27, 95% CI: 0.89 to 18.15, P = 0.07), patient satisfaction (WMD: 4.01, 95% CI: 0.07 to 22.72, P = 0.87), residual sphere (WMD: -0.03, 95% CI: -0.18 to 0.13, P = 0.74), SE (WMD: 0.04, 95% CI: -0.09 to 0.16, P = 0.55) or complications (WMD: 2.08, 95% CI: 0.35 to 12.43, P = 0.42). Trifocal IOL technology (especially AT Lisa trifocal 839M trifocal) had a clear advantage over bifocal IOLs in intermediate visual acuity, while both trifocal IOLs and bifocal IOLs showed excellent performance in distance visual acuity. AT Lisa trifocal 839M trifocal could provide better uncorrected near visual acuity than bifocal IOLs. However, more evidence is needed to compare their spectacle independence, higher satisfaction rate, and photic phenomena.

  2. Comparison of intraocular lens types for cataract surgery in eyes with uveitis

    PubMed Central

    Ssemanda, Elizabeth; Lindsley, Kristina; Ervin, Ann-Margret; Kempen, John

    2013-01-01

    This is the protocol for a review and there is no abstract. The objectives are as follows: The aim of this systematic review is to summarize the effects of different IOLs after cataract surgery in uveitis patients. Alternative types of IOLs include PMMA, silicone, acrylic with or without heparin-surface modification. PMID:25013384

  3. 42 CFR 416.185 - Process for establishing a new class of new technology IOLs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Payment Amounts for New Technology Intraocular Lenses Furnished by Ambulatory Service Centers § 416.185 Process for establishing a new class of new technology IOLs. (a) Announcement of deadline for requests for review. CMS announces the deadline for each year's requests for review of a new class of new technology...

  4. Integrated Online Software for Libraries: An Overview of Today's Best-Selling IOLS. Options from the U.S. Perspective.

    ERIC Educational Resources Information Center

    Cibbarelli, Pamela

    1996-01-01

    Profiles the top-selling IOLS (integrated online library systems) software for libraries based on sales figures reported in the 1996 "Library Journal" annual survey of the library automation marketplace. Highlights include microcomputer-based systems and minicomputer-based systems, system components, MARC formats, and market sectors.…

  5. Postoperative diffuse opacification of a hydrophilic acrylic intraocular lens: analysis of an explant.

    PubMed

    Cavallini, Gian Maria; Volante, Veronica; Campi, Luca; De Maria, Michele; Fornasari, Elisa; Urso, Giancarlo

    2017-06-14

    We describe the clinicopathological and ultrastructural features of an opaque single-piece hydrophilic acrylic intraocular lens (IOL) explanted from a patient. The main outcome of this report is the documentation of calcium deposits confirmed by surface analysis. The decrease in visual acuity was due to the opacification of the IOL. The opacification involved both the optic plate and the haptics. The analysis at the scansion electron microscope revealed that the opacity was caused by the deposition of calcium and phosphate within the lens optic and haptics. This is the first case about the opacification of an Oculentis L-313. The opacification was characterized by calcium and phosphate deposition probably due to a morphological alteration of the posterior surface of the IOL.

  6. [The influence of a new surface treatment of silicone intracoular lenses with fluoralkylsitan on the adherence of endophthalmitic bacteria in vitro

    PubMed

    Kienast, A; Menz, D-H; Dresp, J; Klinger, M; Bunse, A; Ohgke, H; Solbach, W; Laqua, H; Kämmerer, R; Hoerauf, H

    2003-10-01

    Dynasilan is a fluoroalkylsilan which is able to bind to surface active molecules of intraocular lenses (IOLs), thereby offering a new option for surface modification of silicone lenses. The purpose of this in vitro study was to investigate the influence of this new surface treatment on the adherence of two typical endophthalmitis-inducing bacteria ( Staphylococcus epidermidis, Propionibacterium acnes). A total of 14 Dynasilan-treated and 14 untreated silicone lenses were incubated at 37 degrees C for 24 h in brain heart infusion broth (10(8) CFU/ml) either with Staphylococcus epidermidis or with Propionibacterium acnes for 1 h. Subsequently, the adherent bacteria were resuspended using ultrasonification at 35 kHz for 3 x 45 s. After a dilution series and incubation at 37 degrees C for 24 h or 3 days the colonies were counted. On untreated IOLs incubated with Staphylococcus epidermidis the average number of bacteria was 3.6 x 10(7)/ml, and on treated IOLs the number of counted colonies was reduced to 1.09 x 10(7)/ml. Incubated with Propionibacterium acnes the average number of adherent bacteria on untreated IOLs was 4.75 x 10(4)/ml and on modified IOLs the number was reduced to 2.94 x 10(4)/ml. Dynasilan surface treatment may reduce the adherence of Staphylococcus epidermidis and Propionibacterium acnes on silicone intraocular lenses. Further studies regarding the stability of this treatment, its biocompatibility and influence on lens epithelial cell adhesion are in progress.

  7. Astigmatism Correction With Toric Intraocular Lenses in Descemet Membrane Endothelial Keratoplasty Triple Procedures.

    PubMed

    Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A

    2017-03-01

    To report the clinical efficacy of astigmatism correction with toric intraocular lenses (IOLs) in patients undergoing the Descemet membrane endothelial keratoplasty (DMEK) triple procedure and to evaluate the accuracy of the correction. Fifteen eyes of 10 patients who received cataract extraction, toric IOL placement, and DMEK surgery for Fuchs corneal dystrophy and cataracts were evaluated. The cylinder power of toric IOLs was determined by an online toric calculator with keratoscopy measurements obtained using Scheimpflug corneal imaging. Prediction errors were assessed as a difference vector between the anticipated minus postoperative residual astigmatism. At 10.1 ± 4.9 months postoperatively, 8/13 (61.5%) of eyes achieved uncorrected distance visual acuity better than 20/40. Mean best spectacle-corrected distance visual acuity (logMAR) improved from 0.21 ± 0.15 preoperatively to 0.08 ± 0.12 postoperatively (P < 0.01). The magnitude of refractive astigmatism was also significantly decreased from 2.23 ± 1.10 D (range 0.75-4.25 D) preoperatively to 0.87 ± 0.75 D (range 0.00-3.00 D) postoperatively (P < 0.01). In 1 eye with rotational misalignment by 43 degrees, we found no improvement of astigmatism. The prediction error of astigmatism at the corneal plane was 0.77 ± 0.54 D (range 0.10-1.77 D). Four eyes with preoperative "with-the-rule" corneal astigmatism had postoperative "against-the-rule" refractive astigmatism. For patients with Fuchs corneal dystrophy and cataracts, use of toric IOLs might be a valuable option in triple DMEK surgery. Additionally, care should be taken to prevent excessive IOL rotation.

  8. Ultraviolet-B phototoxicity and hypothetical photomelanomagenesis: intraocular and crystalline lens photoprotection.

    PubMed

    Mainster, Martin A; Turner, Patricia L

    2010-04-01

    Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Optical radiation measurement, analysis, and perspective. Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Crystalline lens UV-B retinal protection is deficient in children and young adults, increasing their potential susceptibility to acute retinal phototoxicity and hypothetical photomelanomagenesis. UV-B radiation has sufficient energy/photon to induce primary melanomagenic DNA lesions, unlike blue light or UV-A radiation. UV-blocking and blue-blocking IOLs have negligible UV-B transmittance. UV-transmitting IOL transmittance of UV-B radiation is equivalent to that of a 15-year-old crystalline lens. If optical radiation exposure is responsible for welders' increased risk of uveal melanoma, then UV-B radiation is the most probable causative agent and spectacle wear is a potential confounding factor in epidemiologic studies of ocular melanoma. Welders under 30 years of age are at greater risk for welding maculopathy than older welders. Children, adults under 30 years of age, and pseudophakic individuals with UV-transmitting IOLs should wear sunglasses in bright environments because of the UV-B window in their crystalline lenses or IOLs. Copyright 2010 Elsevier Inc. All rights reserved.

  9. Distance and near visual acuity improvement after implantation of multifocal intraocular lenses in cataract patients with presbyopia: a systematic review.

    PubMed

    Agresta, Blaise; Knorz, Michael C; Kohnen, Thomas; Donatti, Christina; Jackson, Daniel

    2012-06-01

    To evaluate uncorrected distance visual acuity (UDVA) as well as uncorrected near visual acuity (UNVA) as outcomes in treating presbyopic cataract patients to assist clinicians and ophthalmologists in their decision-making process regarding available interventions. Medline, Embase, and Evidence Based Medicine Reviews were systematically reviewed to identify studies reporting changes in UDVA and UNVA after cataract surgery in presbyopic patients. Strict inclusion/exclusion criteria were used to exclude any studies not reporting uncorrected visual acuity in a presbyopic population with cataracts implanted with multifocal intraocular lenses (IOLs). Relevant outcomes (UDVA and UNVA) were identified from the studies retrieved through the systematic review process. Twenty-nine studies were identified that reported uncorrected visual acuities, including one study that reported uncorrected intermediate visual acuity. Nine brands of multifocal IOLs were identified in the search. All studies identified in the literature search reported improvements in UDVA and UNVA following multifocal IOL implantation. The largest improvements in visual acuity were reported using the Rayner M-Flex lens (Rayner Intraocular Lenses Ltd) (UDVA, binocular: 1.05 logMAR, monocular: 0.92 logMAR; UNVA, binocular and monocular: 0.83 logMAR) and the smallest improvements were reported using the Acri.LISA lens (Carl Zeiss Meditec) (UDVA, 0.21 decimal; UNVA, 0.51 decimal). The results of this systematic review show the aggregate of studies reporting a beneficial increase in UDVA and UNVA with the use of multifocal IOLs in cataract patients with presbyopia, hence providing evidence to support the hypothesis that multifocal IOLs increase UDVA and UNVA in cataract patients. Copyright 2012, SLACK Incorporated.

  10. Can the accuracy of multifocal intraocular lens power calculation be improved to make patients spectacle free?

    PubMed

    Ramji, Hasnain; Moore, Johnny; Moore, C B Tara; Shah, Sunil

    2016-04-01

    To optimise intraocular lens (IOL) power calculation techniques for a segmental multifocal IOL, LENTIS™ MPlus(®) (Oculentis GmbH, Berlin, Germany) and assess outcomes. A retrospective consecutive non-randomised case series of patients receiving the MPlus(®) IOL following cataract surgery or clear lens extraction was performed at a privately owned ophthalmic hospital, Midland Eye, Solihull, UK. Analysis was undertaken of 116 eyes, with uncomplicated lens replacement surgery using the LENTIS™ MPlus(®) lenses. Pre-operative biometry data were stratified into short (<22.00 mm) and long axial lengths (ALs) (≥22.00 mm). IOL power predictions were calculated with SRK/T, Holladay I, Hoffer Q, Holladay II and Haigis formulae and compared to the final manifest refraction. These were compared with the OKULIX ray tracing method and the stratification technique suggested by the Royal College of Ophthalmologists (RCOphth). Using SRK/T for long eyes and Hoffer Q for short eyes, 64% achieved postoperative subjective refractions of ≤±0.25 D, 83%≤±0.50 D and 93%≤±0.75 D, with a maximum predictive error of 1.25D. No specific calculation method performed best across all ALs; however for ALs under 22 mm Hoffer Q and Holliday I methods performed best. Excellent but equivalent overall refractive results were found between all biometry methods used in this multifocal IOL study. For eyes with ALs under 22 mm Hoffer Q and Holliday I performed best. Current techniques mean that patients are still likely to need top up glasses for certain situations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Patient-centered and visual quality outcomes of premium cataract surgery: a systematic review.

    PubMed

    Wang, Sophia Y; Stem, Maxwell S; Oren, Gale; Shtein, Roni; Lichter, Paul R

    2017-06-26

    Over 8 million cataract surgeries are performed in the United States and the European Union annually, with many patients choosing to pay out of pocket for premium options including premium intraocular lens implants (IOLs) or laser-assisted cataract surgery (LACS). This report provides a systematic review evaluating patient-centered and visual quality outcomes comparing standard monofocal IOLs to premium cataract surgery options. PubMed and EMBASE were searched for publications published between January 1, 1980, and September 18, 2016, on multifocal, accommodative, and toric IOLs, monovision, and LACS, which reported on 1) dysphotopsias, 2) contrast sensitivity, 3) spectacle independence, 4) vision-related quality of life or patient satisfaction, and 5) IOL exchange. Multifocal lenses achieved higher rates of spectacle independence compared to monofocal lenses but also had higher reported frequency of dysphotopsia and worse contrast sensitivity, especially with low light or glare. Accommodative lenses were not associated with reduced contrast sensitivity or more dysphotopsia but had only modest improvements in spectacle independence compared to monofocal lenses. Studies of monovision did not target a sufficiently myopic outcome in the near-vision eye to achieve the full potential for spectacle independence. Patients reported high levels of overall satisfaction regardless of implanted IOL. No studies correlated patient-reported outcomes with patient expectations. Studies are needed to thoroughly compare patient-reported outcomes with concomitant patient expectations. In light of the substantial patient costs for premium options, patients and their surgeons will benefit from a better understanding of which surgical options best meet patients' expectations and how those expectations can be impacted by premium versus monofocal-including monovision-options.

  12. Color of intra-ocular lens and cataract type are prognostic determinants of health indices after visual and photoreceptive restoration by surgery.

    PubMed

    Ayaki, Masahiko; Negishi, Kazuno; Suzukamo, Yoshimi; Tsubota, Kazuo

    2015-04-01

    This study compared post-operative quality of life and sleep according to the type of cataract opacity and color of the implanted intra-ocular lens (IOL). This is a cohort study and participants were 206 patients (average age 74.1 years) undergoing cataract surgery with the implantation of a clear ultra-violet (UV)-blocking IOL (C) or a yellow blue-light-blocking IOL (Y). Participants were evaluated using the National Eye Institute Visual Function Questionnaire (VFQ-25) and Pittsburgh Sleep Quality Index (PSQI) before surgery and 2 and 7 months after surgery. Changes in sub-scale scores of VFQ-25 and PSQI were compared. Sub-scale analyses for improvement after surgery revealed significant differences in ocular pain scores on the VFQ-25 (Y>C; the higher the score, the better the outcome). Furthermore, there were significant differences between the two IOLs in terms of the sleep latency score (C>Y) and sleep disturbances score (C>Y). A posterior sub-capsular cataract was significantly correlated with improvements in ocular pain and sleep latency scores. These effects were successfully represented by the change in scores rather than absolute post-operative scores because individual standard of response may often change after intervention, recognized as a response shift phenomenon in patient-reported outcome study. Regarding seasonal differences, patients who had surgery in summer exhibited relatively better sleep quality than those who had surgery in winter. Analysis of sub-scales of health indices demonstrated characteristic prognoses for each IOL and cataract type. Cataract surgery may potentially contribute to systemic health in older adults.

  13. Photochemical generation of antimicrobial Ag-nanoparticles in intraocular lenses

    NASA Astrophysics Data System (ADS)

    Badur, Thorben; Kim, Hee-Cheol; Hampp, Norbert

    2017-02-01

    The antimicrobial properties of silver (Ag) nanoparticles (NP) have been investigated in depth during the last decades.[1] For cataract treatment minimal invasive surgery has become state-of-the-art. The physicians are still fighting against postoperative inflammations, such as endophthalmitis.[2] We present a novel approach to reduce these postoperative complications by equipping the hydrophilic intraocular lenses (IOL) with a Ag NP depot. As the Ag NP are completely entrapped inside the polymeric IOL no direct contact of the nanoparticles with epithelial cells may occur. Using 1-hydroxybenzotriazole (HOBt) or 7-hydroxycumarine (7HOCum) as photo reduction mediators (PRM) the formation of the Ag NP is accomplished in situ. PRM and Ag nitrate are diffused into the ready made IOL. By means of two-photon-absorption (TPA) photochemistry at λTPA = 532 nm the Ag NP generation is precisely controlled to occur inside the IOL only. At no point NP are directly exposed to the surface.[3] Interesting dependencies between the used PRM and the resulting particle size distribution or the effectiveness of the silver ion reduction inside the polymer matrix are reported. The Ag NP were prepared in the outer area of the IOL not to affect the optical properties of the ophthalmic implant. The amount of Ag ions released was determined and found to be sufficient to effectively reduce the counts of airborne germs. Besides HOBt and 7HOCum we also investigated the photo reductive properties of several other organic reagents, such as benzophenone (BP) and 4-hydroxybenzophenone (4HOBP) for the ability to produce even three-dimensional nanoparticle structures inside a polymer matrix.

  14. Primary iris claw IOL retrofixation with intravitreal triamcinolone acetonide in cases of inadequate capsular support.

    PubMed

    Kelkar, Aditya; Shah, Rachana; Vasavda, Viraj; Kelkar, Jai; Kelkar, Shreekant

    2018-02-01

    To assess the outcomes and analyze complication rates following primary iris claw IOL retrofixation with intravitreal triamcinolone acetonide. This is a retrospective interventional case series. Patients with poor capsular support-diagnosed preoperatively or owing to intraoperative complications-were treated with iris claw IOL retrofixation with intravitreal triamcinolone acetonide. The data were retrospectively analyzed. 104 eyes of 102 patients with poor capsular support who underwent the procedure between 2010 and 2013 were analyzed. The minimum follow-up period was 12 months (ranging from 12 to 36 months). Iris claw IOL was implanted in-traumatic subluxated cataracts-24 cases (23.07%), non-traumatic subluxated cataracts in 16 cases (15.38%), or as a complication of cataract surgery-intraoperative posterior capsular rent in 48 cases (46.15%) and intraoperative nucleus drop in 16 cases (15.38%). The final mean best-corrected logMAR visual acuity improved from 1.36 ± 0.64 preoperatively to 0.36 ± 0.32 at 1-year follow-up. Complications included pupil ovalization in 11 cases (10.57%), transient elevation in intraocular pressure in 7 eyes (6.73%), postoperative hypotony in 5 eyes (4.80%), cystoid macular edema in 2 eyes (1.92%), retinal detachment in 1 eye (0.96%), vitreous hemorrhage in 1 eye (0.96%), and hyphema in 1 eye (0.96%). Primary iris claw IOL retrofixation provided excellent alternative in patients with inadequate capsular support. The visual outcomes were good along with favorable rates of complications. The addition of triamcinolone acetonide helps in reducing the chances of cystoid macular edema.

  15. Anterior stromal puncture with staining: A modified technique for preoperative reference corneal marking for toric lenses and its retrospective analyses.

    PubMed

    Bhandari, Sahil; Nath, Manas

    2016-08-01

    Toric intraocular lenses (IOLs) are an effective way of compensating preexisting corneal astigmatism during cataract surgery. To achieve success, it is imperative to align the toric IOLs in desired position and preoperative reference marking is one among the three important steps for accurate alignment. To make the marking procedure simpler and effective, we have modified the conventional three-step slit lamp-based technique. Patient is seated in front of the slit lamp and asked to keep the chin over chin rest. A 26-gauge bent needle with tip stained by sterile blue ink marker is used to make anterior stromal puncture (ASP) at the edges of horizontal 180° axis near the limbus. A total of 58 eyes were retrospectively evaluated. Mean (+/-SD) IOL deviation on day 1 and day 30 was 5.7 ± 6.5° and 4.7 ± 5.6°, respectively. Median IOL misalignment on day 1 and day 30 was 3°. Redialing of IOL was required in 2 (3.4%) eyes only, all of which were performed within 1 week of surgery. In total, 2 (3.7%) eyes had a residual astigmatism of - 0.5 Dcyl and - 1.0 Dcyl, respectively. ASP is an effective technique for reference marking, technically simpler and can be practiced by most of the surgeons. It avoids the necessity of high-end sophisticated machinery and gives a better platform for the reference corneal marking along with the benefit of reproducibility and simplicity.

  16. Software-based evaluation of toric IOL orientation in a multicenter clinical study.

    PubMed

    Kasthurirangan, Sanjeev; Feuchter, Lucas; Smith, Pamela; Nixon, Donald

    2014-12-01

    To evaluate the rotational stability of a new one-piece hydrophobic acrylic toric intraocular lens (IOL) using a custom-developed software for analysis of slit-lamp photographs. In a prospective, multicenter study, 174 eyes were implanted with the TECNIS Toric IOL (Abbott Medical Optics, Inc., Santa Ana, CA). A custom-developed software was used to analyze high-resolution slit-lamp photographs of 156 eyes taken at day 1 (baseline) and 1, 3, and 6 months postoperatively. The software uses iris and sclera landmarks to align the baseline image and later images for comparison. Validation of software was performed through repeated analyses of protractor images rotated from 0.1° to 10.0° and randomly selected photographs of 20 eyes. Software validation showed precision (repeatability plus reproducibility variation) of 0.02° using protractor images and 2.22° using slit-lamp photographs. Good quality slit-lamp images and clear landmarks were necessary for precise measurements. At 6 months, 94.2% of eyes had 5° or less change in IOL orientation versus baseline; only 2 eyes (1.4%) had axis shift greater than 30°. Most eyes were within 5° or less of rotation between 1 and 3 months (92.9%) and 3 and 6 months (94.1%). Mean absolute axis change (± standard deviation) from 1 day to 6 months was 2.70° ± 5.51°. The new custom software was precise and quick in analyzing slit-lamp photographs to determine postoperative toric IOL rotation. Copyright 2014, SLACK Incorporated.

  17. Failure Modes and Effects Analysis of bilateral same-day cataract surgery

    PubMed Central

    Shorstein, Neal H.; Lucido, Carol; Carolan, James; Liu, Liyan; Slean, Geraldine; Herrinton, Lisa J.

    2017-01-01

    PURPOSE To systematically analyze potential process failures related to bilateral same-day cataract surgery toward the goal of improving patient safety. SETTING Twenty-one Kaiser Permanente surgery centers, Northern California, USA. DESIGN Retrospective cohort study. METHODS Quality experts performed a Failure Modes and Effects Analysis (FMEA) that included an evaluation of sterile processing, pharmaceuticals, perioperative clinic and surgical center visits, and biometry. Potential failures in human factors and communication (modes) were identified. Rates of endophthalmitis, toxic anterior segment syndrome (TASS), and unintended intraocular lens (IOL) implantation were assessed in eyes having bilateral same-day surgery from 2010 through 2014. RESULTS The study comprised 4754 eyes. The analysis identified 15 significant potential failure modes. These included lapses in instrument processing and compounding error of intracameral antibiotic that could lead to endophthalmitis or TASS and ambiguous documentation of IOL selection by surgeons, which could lead to unintended IOL implantation. Of the study sample, 1 eye developed endophthalmitis, 1 eye had unintended IOL implantation (rates, 2 per 10 000; 95% confidence intervals [CI] 0.1–12.0 per 10 000), and no eyes developed TASS (upper 95% CI, 8 per 10 000). Recommendations included improving oversight of cleaning and sterilization practices, separating lots of compounded drugs for each eye, and enhancing IOL verification procedures. CONCLUSIONS Potential failure modes and recommended actions in bilateral same-day cataract surgery were determined using a FMEA. These findings might help improve the reliability and safety of bilateral same-day cataract surgery based on current evidence and standards. PMID:28410711

  18. Images created in a model eye during simulated cataract surgery can be the basis for images perceived by patients during cataract surgery

    PubMed Central

    Inoue, M; Uchida, A; Shinoda, K; Taira, Y; Noda, T; Ohnuma, K; Bissen-Miyajima, H; Hirakata, A

    2014-01-01

    Purpose To evaluate the images created in a model eye during simulated cataract surgery. Patients and methods This study was conducted as a laboratory investigation and interventional case series. An artificial opaque lens, a clear intraocular lens (IOL), or an irrigation/aspiration (I/A) tip was inserted into the ‘anterior chamber' of a model eye with the frosted posterior surface corresponding to the retina. Video images were recorded of the posterior surface of the model eye from the rear during simulated cataract surgery. The video clips were shown to 20 patients before cataract surgery, and the similarity of their visual perceptions to these images was evaluated postoperatively. Results The images of the moving lens fragments and I/A tip and the insertion of the IOL were seen from the rear. The image through the opaque lens and the IOL without moving objects was the light of the surgical microscope from the rear. However, when the microscope light was turned off after IOL insertion, the images of the microscope and operating room were observed by the room illumination from the rear. Seventy percent of the patients answered that the visual perceptions of moving lens fragments were similar to the video clips and 55% reported similarity with the IOL insertion. Eighty percent of the patients recommended that patients watch the video clip before their scheduled cataract surgery. Conclusions The patients' visual perceptions during cataract surgery can be reproduced in the model eye. Watching the video images preoperatively may help relax the patients during surgery. PMID:24788007

  19. [Control of corneal astigmatism following IOL implantation by Nd:YAG laser selective suture cutting].

    PubMed

    Liu, Y Z; Li, S Z

    1991-09-01

    Nd:YAG laser was used to cut the sutures selectively to reduce the postoperative corneal with-the-rule astigmatism in 48 eyes that underwent posterior chamber IOL implantation. A significant decrease in corneal astigmatism with visual improvement was affected, and the manipulation was simple. The actual procedure with its advantages and disadvantages was discussed.

  20. The Impact of Different Modalities on Student Retention and Overall Engagement Patterns in Open Online Courses

    ERIC Educational Resources Information Center

    Friðriksdóttir, Kolbrún

    2018-01-01

    This article presents an analysis of tracking data collected over eight years on 43,000 users on "Icelandic Online (IOL)," seven open, guided online courses in Icelandic as a second language. The main objective in this study is to (a) map out retention for all the "IOL" courses, (b) compare retention on the same course…

  1. Energy balance in apodized diffractive multifocal intaocular lenses

    NASA Astrophysics Data System (ADS)

    Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.

    2011-08-01

    The energy distribution between the distance and near images formed in a model eye by three different apodized diffractive multifocal intraocular lenses (IOLs) is experimentally determined in an optical bench. The model eye has an artificial cornea with positive spherical aberration (SA) similar to human cornea. The level of SA upon the IOL, which is pupil size dependent, is controlled using a Hartmann-Shack wave sensor. The energy of the distance and near images as a function of the pupil size is experimentally obtained from image analysis. All three IOLs have the same base refractive power (20D) but different designs (aspheric, spherical) and add powers (+4.0 D, +3.0 D). The results show that in all the cases, the energy efficiency of the distance image decreases for large pupils, in contrast with the theoretical and simulated results that only consider the diffractive profile of the lens. As for the near image, since the diffractive zone responsible for the formation of this image has the same apodization factor in the spherical and aspheric lenses and the apertures involved are small (and so the level of SA), the results turn out to be similar for all the three IOL designs.

  2. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    PubMed Central

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    AIM To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). METHODS Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected. PMID:29181318

  3. Iron Overload and Chelation Therapy in Non-Transfusion Dependent Thalassemia

    PubMed Central

    Bou-Fakhredin, Rayan; Bazarbachi, Abdul-Hamid; Chaya, Bachar; Sleiman, Joseph; Cappellini, Maria Domenica; Taher, Ali T.

    2017-01-01

    Iron overload (IOL) due to increased intestinal iron absorption constitutes a major clinical problem in patients with non-transfusion-dependent thalassemia (NTDT), which is a cumulative process with advancing age. Current models for iron metabolism in patients with NTDT suggest that suppression of serum hepcidin leads to an increase in iron absorption and subsequent release of iron from the reticuloendothelial system, leading to depletion of macrophage iron, relatively low levels of serum ferritin, and liver iron loading. The consequences of IOL in patients with NTDT are multiple and multifactorial. Accurate and reliable methods of diagnosis and monitoring of body iron levels are essential, and the method of choice for measuring iron accumulation will depend on the patient’s needs and on the available facilities. Iron chelation therapy (ICT) remains the backbone of NTDT management and is one of the most effective and practical ways of decreasing morbidity and mortality. The aim of this review is to describe the mechanism of IOL in NTDT, and the clinical complications that can develop as a result, in addition to the current and future therapeutic options available for the management of IOL in NTDT. PMID:29261151

  4. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    PubMed

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  5. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    PubMed

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  6. Iris-Claw Intraocular Lens and Scleral-Fixated Posterior Chamber Intraocular Lens Implantations in Correcting Aphakia: A Meta-Analysis.

    PubMed

    Jing, Wu; Guanlu, Liang; Qianyin, Zheng; Shuyi, Li; Fengying, He; Jian, Liu; Wen, Xu

    2017-07-01

    A meta-analysis to compare iris-claw intraocular lens (IC-IOL) and scleral-fixated posterior chamber intraocular lens (SF-PCIOL) implantations in correcting aphakia without sufficient capsular support. Eligible studies were collected through PubMed, Web of Science, Embase, and the Cochrane library. The pooled relative risks (RR), pooled standardized mean difference (SMD), and their 95% confidence interval of the eligible studies were then calculated. Seven studies met our inclusion criteria, involving 232 and 158 eyes in IC-IOL and SF-PCIOL groups, respectively. The pooled SMD of the mean postoperative corrected distance visual acuity (CDVA) (logMAR) was -0.25. The pooled RR of the eyes achieving 20/40 or better postoperatively was 1.16. The pooled SMD of the surgical time was -2.97. The pooled RR of the surgical complications was 0.86. The pooled RR of IOL dislocation, retinal detachment (RD), and cystoid macular edema (CME) between the two groups were 0.22, 0.63, and 0.64. Implantation of IC-IOL has a more simple procedure and shorter learning curve than SF-PCIOL implantation in correcting aphakia without sufficient capsular support.

  7. Mechanical properties of intra-ocular lenses

    NASA Astrophysics Data System (ADS)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  8. Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths.

    PubMed

    Karabela, Yunus; Eliacik, Mustafa; Kaya, Faruk

    2016-07-08

    The SRK/T formula is one of the third generation IOL calculation formulas. The purpose of this study was to evaluate the performance of the SRK/T formula in predicting a target refraction ±1.0D in short and long eyes using ultrasound biometry after phacoemulsification. The present study was a retrospective analysis, which included 38 eyes with an AL < 22.0 mm (short AL), and 62 eyes ≥24.6 mm (long AL) that underwent uncomplicated phacoemulsification. Preoperative AL was measured by ultrasound biometry and SRK/T formula was used for IOL calculation. Three different IOLs were implanted in the capsular bag. The prediction error was defined as the difference between the achieved postoperative refraction, and attempted predicted target refraction. Statistical analysis was performed with SPSS V21. In short ALs, the mean age was 65.13 ± 9.49 year, the mean AL was 21.55 ± 0.45 mm, the mean K1 and K2 were 45.76 ± 1.77D and 46.09 ± 1.61D, the mean IOL power was 23.96 ± 1.92D, the mean attempted (predicted) value was 0.07 ± 0.26D, the mean achieved value was 0.07 ± 0.63 D, the mean PE was 0.01 ± 0.60D, and the MAE was 0.51 ± 0.31D. A significant positive relationship with AL and K1, K2, IOL power and a strong negative relationship with PE and achieved postoperative was found. In long ALs, the mean age was 64.05 ± 7.31 year, the mean AL was 25.77 ± 1.64 mm, the mean K1 and K2 were 42.20 ± 1.57D and 42.17 ± 1.68D, the mean IOL power was 15.79 ± 5.17D, the mean attempted value was -0.434 ± 0.315D, the mean achieved value was -0.42 ± 0.96D, the mean PE was -0.004 ± 0.93D, the MAE was 0.68 ± 0.62D. A significant positive relationship with AL and K1, K2 and a significant positive relationship with PE and achieved value, otherwise a negative relationship with AL and IOL power was found. There was a little tendency towards hyperopic for short ALs and myopic for long ALs. The majority of eyes (94.74 %) for short ALs and (70.97 %) for long ALs were within ±1 D of the predicted refractive error. No significant relationship with PE and IOL types, AL, K1, K2, IOL power, and attempted value, besides with MAE and AL, K1, K2, age, attempted, achieved value were found in both groups. The SRK/T formula performs well and shows good predictability in eyes with short and long axial lengths.

  9. [Implantation of a sulcus-fixated toric additive intraocular lens in a case of high astigmatism after a triple procedure].

    PubMed

    Linz, K; Auffarth, G U; Kretz, F T A

    2014-08-01

    Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D. A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, - 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and - 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to - 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed. Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of the IOL. Georg Thieme Verlag KG Stuttgart · New York.

  10. Posterior chamber phakic intraocular lens sizing based on iris pigment layer measurements by anterior segment optical coherence tomography.

    PubMed

    Malyugin, Boris E; Shpak, Alexander A; Pokrovskiy, Dmitry F

    2015-08-01

    To use anterior segment optical coherence tomography (AS-OCT) to evaluate the clinical effectiveness of Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) sizing based on measurement of the distance from the iris pigment end to the iris pigment end. S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russia. Evaluation of diagnostic test or technology. Stage 1 was a prospective study. The sulcus-to-sulcus (STS) distance was measured using ultrasound biomicroscopy (UBM) (Vumax 2), and the distance from iris pigment end to iris pigment end was assessed using a proposed AS-OCT algorithm. Part 2 used retrospective data from patients after implantation of a PC pIOL with the size selected according to AS-OCT (Visante) measurements of the distance from iris pigment end to iris pigment end. The PC pIOL vault was measured by AS-OCT, and adverse events were assessed. Stage 1 comprised 32 eyes of 32 myopic patients (mean age 28.4 years ± 6.3 [SD]; mean spherical equivalent [SE] -13.11 ± 4.28 diopters [D]). Stage 2 comprised 29 eyes of 16 patients (mean age 27.7 ± 4.7 years; mean SE -16.55 ± 3.65 D). The mean STS distance (12.35 ± 0.47 mm) was similar to the mean distance from iris pigment end to iris pigment end distance (examiner 1: 12.36 ± 0.51 mm; examiner 2: 12.37 ± 0.53 mm). The PC pIOL sized using the new AS-OCT algorithm had a mean vault of 0.53 ± 0.18 mm and did not produce adverse events during the 12-month follow-up. In 16 of 29 eyes, the PC pIOL vault was within an optimum interval (0.35 to 0.70 mm). The new measurement algorithm can be effectively used for PC pIOL sizing. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Improving women's knowledge of prostaglandin induction of labour through the use of information brochures: a quasi-experimental study.

    PubMed

    Cooper, Megan; Warland, Jane

    2011-12-01

    To gain a better understanding of women's baseline level of knowledge of induction of labour (IOL) and determine whether giving written information at the time IOL is decided, results in significant differences in knowledge and understanding of the process. Fifty pregnant women undergoing antenatal care at a small maternity hospital were recruited. A quasi experimental trial was conducted with non random selection of participants, 25 selected to act as the control group and 25 selected as the intervention group. The study was conducted to determine women's knowledge of IOL both before (non-intervention) and after (intervention) the introduction of a written information brochure. Statistically significant increases in knowledge were evident in the intervention group for knowledge about action (p=0.002) and timing of prostaglandins (p=0.03), the number of side effects known (p<0.0001) as well as time to birth (p=0.001) indicating an increased understanding of the process as a result of reading an information brochure. These results suggest that those in the non-intervention group lacked knowledge pertinent to IOL, even though they have consented to and actually arrived at the hospital prepared to undergo the IOL procedure. The most significant disparity noted between the intervention and non-intervention groups was women's knowledge of side effects of prostaglandin. Further to this, many women in the non-intervention group had unrealistic expectations of both the time for drug action and likely time from prostaglandin administration to birth. In contrast women in the intervention group knew about the common side effects of prostaglandin and possessed a more realistic understanding of the likely time to birth following this procedure. The results indicate that a specifically designed information brochure explaining the process of IOL in plain language has the effect of enhancing women's knowledge. This area of study warrants further investigation, especially research into the role of written information to improve women's understanding across other areas of maternity care education provision. Copyright © 2010 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  12. Optical Coherence Tomography–Based Corneal Power Measurement and Intraocular Lens Power Calculation Following Laser Vision Correction (An American Ophthalmological Society Thesis)

    PubMed Central

    Huang, David; Tang, Maolong; Wang, Li; Zhang, Xinbo; Armour, Rebecca L.; Gattey, Devin M.; Lombardi, Lorinna H.; Koch, Douglas D.

    2013-01-01

    Purpose: To use optical coherence tomography (OCT) to measure corneal power and improve the selection of intraocular lens (IOL) power in cataract surgeries after laser vision correction. Methods: Patients with previous myopic laser vision corrections were enrolled in this prospective study from two eye centers. Corneal thickness and power were measured by Fourier-domain OCT. Axial length, anterior chamber depth, and automated keratometry were measured by a partial coherence interferometer. An OCT-based IOL formula was developed. The mean absolute error of the OCT-based formula in predicting postoperative refraction was compared to two regression-based IOL formulae for eyes with previous laser vision correction. Results: Forty-six eyes of 46 patients all had uncomplicated cataract surgery with monofocal IOL implantation. The mean arithmetic prediction error of postoperative refraction was 0.05 ± 0.65 diopter (D) for the OCT formula, 0.14 ± 0.83 D for the Haigis-L formula, and 0.24 ± 0.82 D for the no-history Shammas-PL formula. The mean absolute error was 0.50 D for OCT compared to a mean absolute error of 0.67 D for Haigis-L and 0.67 D for Shammas-PL. The adjusted mean absolute error (average prediction error removed) was 0.49 D for OCT, 0.65 D for Haigis-L (P=.031), and 0.62 D for Shammas-PL (P=.044). For OCT, 61% of the eyes were within 0.5 D of prediction error, whereas 46% were within 0.5 D for both Haigis-L and Shammas-PL (P=.034). Conclusions: The predictive accuracy of OCT-based IOL power calculation was better than Haigis-L and Shammas-PL formulas in eyes after laser vision correction. PMID:24167323

  13. Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

    PubMed

    Eom, Youngsub; Ryu, Dongok; Kim, Dae Wook; Yang, Seul Ki; Song, Jong Suk; Kim, Sug-Whan; Kim, Hyo Myung

    2016-10-01

    To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Two thousand samples of corneal parameters with keratometric astigmatism ≥ 1.0 D were obtained using bootstrap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.

  14. Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism

    PubMed Central

    Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon

    2016-01-01

    Purpose To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. Materials and Methods The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00–4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. Results The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Conclusion Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes. PMID:27593877

  15. Intraoperative aberrometry-based aphakia refraction in patients with cataract: status and options.

    PubMed

    Huelle, Jan O; Druchkiv, Vasyl; Habib, Nabil E; Richard, Gisbert; Katz, Toam; Linke, Stephan J

    2017-02-01

    To explore the application of intraoperative wavefront aberrometry (IWA) for aphakia-based biometry using three existing formulae derived from autorefractive retinoscopy and introducing new improved formulae. In 74 patients undergoing cataract surgery, three repeated measurements of aphakic spherical equivalent (SE) were taken. All measurements were objectively graded for their quality and evaluated with the 'limits of agreement' approach. ORs were calculated and analysis of variance was applied. The intraocular lens (IOL) power that would have given the target refraction was back-calculated from manifest refraction at 3 months postoperatively. Regression analysis was performed to generate two aphakic SE-based formulae for predicting this IOL. The accuracy of the formulae was determined by comparing them to conventional biometry and published aphakia formulae. In 32 eyes, three consecutive aphakic measurements were successful. Objective parameters of IWA map quality significantly impacted measurement variability (p<0.05). The limits of agreement of repeated aphakic SE readings were +0.66 dioptre (D) and -0.69 D. Intraoperative biometry by our formula resulted in 25% and 53% of all cases ±0.50D and ±1.00 D within SE target, respectively. A second formula that took axial length (AL) into account resulted in improved ratios of 41% and 70%, respectively. A reliable application of IWA to calculate IOL power during routine cataract surgery may not be feasible given the high rate of measurement failures and the large variations of the readings. To enable reliable IOL calculation from IWA, measurement precision must be improved and aphakic IOL formulae need to be fine-tuned. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Intraocular lens power selection and positioning with and without intraoperative aberrometry.

    PubMed

    Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H

    2015-04-01

    To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.

  17. Preoperative and postoperative size and movements of the lens capsular bag: ultrasound biomicroscopy analysis.

    PubMed

    Modesti, Marina; Pasqualitto, Giacomo; Appolloni, Rossella; Pecorella, Irene; Sourdille, Philippe

    2011-10-01

    To evaluate capsular bag size and accommodative movement before and after cataract surgery using ultrasound biomicroscopy (UBM) and anterior segment optical coherence tomography (AS-OCT). Ophthalmology Unit, Fabia Mater Clinic, Rome, Italy. Cohort study. Eyes having cataract surgery and monofocal intraocular lens (IOL) implantation were studied using UBM. The following parameters were measured preoperatively and 1, 2, and 12 months postoperatively: anterior chamber depth (ACD) (also by AS-OCT), capsular bag thickness, capsular bag diameter, ciliary ring diameter, sulcus-to-sulcus (STS) diameter, ciliary process-capsular bag distance, ciliary apex-capsular bag plane, and IOL tilting. The preoperative and postoperative capsular bag volumes were calculated at 12 months. The results were compared with the changes during accommodation. The study comprised 24 eyes. With the exception of the ciliary apex-capsular bag plane, which appeared to be unmodified postoperatively, all measured parameters showed significant variation after IOL implantation. Only the ACD did not change significantly during accommodation. After cataract surgery, the capsular bag stretched horizontally and with reduced vertical diameter as a result of adaptation to the implanted IOL. The capsular bag-IOL complex filled all available space, compressing the zonular fibers and almost abolishing the space between the ciliary apex and the capsular bag. There was anterior chamber deepening and a decrease in the ciliary ring diameter and STS diameter. In the absence of zonular fiber tension, the shape of the ciliary processes may be modified. No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs.

    PubMed

    Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J

    2012-02-01

    To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.

  19. Effect of supplementary implantation of a sulcus-fixated intraocular lens in patients with negative dysphotopsia.

    PubMed

    Makhotkina, Natalia Y; Dugrain, Vincent; Purchase, Daniel; Berendschot, Tos T J M; Nuijts, Rudy M M A

    2018-02-01

    To evaluate whether the outcome of negative dysphotopsia treatment by implantation of a Sulcoflex intraocular lens (IOL) can be understood using individual biometry and optical modeling data. University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands. Retrospective case series. Patients with negative dysphotopsia were treated with supplementary implantation of a sulcus-fixated IOL. Preoperative and postoperative ray-tracing optical models of eyes with negative dysphotopsia were constructed in the Zemax Optic Studio program using individual biometric data. The relationship between biometric parameters, ray-tracing data, and the course of negative dysphotopsia was evaluated. The study comprised 8 patients (10 eyes). After surgery, negative dysphotopsia resolved completely in 6 eyes, partially in 2 eyes, and persisted in 2 eyes. There was no relationship between the course of negative dysphotopsia and age, IOL power, or individual biometry results other than a larger angle κ that was observed in 2 patients with persistent negative dysphotopsia after surgery. Preoperative ray-tracing models showed a decrease in light irradiance at the periphery relative to the center of visual field. After sulcus-fixated IOL implantation, this decrease partially resolved, in particular, for a small pupil aperture (P < .05), and it was more prominent in patients in whom negative dysphotopsia resolved completely than in those with partial or persistent negative dysphotopsia (P = .065 at 1.5 mm aperture). Of all individual biometry results, only angle κ showed a relationship with the course of negative dysphotopsia. In patient-specific optical modeling of sulcus-fixated IOL implantation, the increase in simulated light irradiance at the periphery was related to the course of negative dysphotopsia. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Comparison of the visual outcomes between PRK-MMC and phakic IOL implantation in high myopic patients

    PubMed Central

    Hashemi, H; Miraftab, M; Asgari, S

    2014-01-01

    Purpose To compare the visual outcomes between PRK-MMC and phakic IOL in patients with more than 8 diopter (D) of myopia. Methods This comparative study was performed on 23 eyes under treatment with Artiflex (group A) and 23 eyes under treatment with PRK-MMC (group B). Artiflex phakic IOL (Ophtec BV) was used in group A, and the VISX STAR S4 Excimer Laser (Abbott) was used for PRK-MMC in group B. Results The safety index was 1.11±0.23 and 1.05±0.25 (P=0.100) and the efficacy index was 1.02±0.11 and 0.98±0.10 (P=0.266) in group A and B, respectively. At 1 year after surgery, the manifest refraction spherical equivalent was −0.17±1.18 and −0.25±0.18 D in group A and B, respectively (P=0.471). Mesopic CS showed no significant difference between the two groups in any spatial frequency. Total coma was 0.24±0.17 and 0.67±0.40 μm (P<0.001), spherical aberration was −0.11±0.11 and 0.41±0.18 μm (P<0.001), and RMS HOAT was 0.50±0.20 and 0.96±0.45 μm (P<0.001) in group A and B, respectively. Conclusion Phakic IOL implantation was better than PRK-MMC in the correction of high myopia in terms of visual quality, but the two methods had no difference with regard to visual acuity. Therefore, PRK-MMC can be used when the anterior chamber depth is a limiting factor in the implantation of phakic IOLs. PMID:24993326

  1. Comparison of the visual outcomes between PRK-MMC and phakic IOL implantation in high myopic patients.

    PubMed

    Hashemi, H; Miraftab, M; Asgari, S

    2014-09-01

    To compare the visual outcomes between PRK-MMC and phakic IOL in patients with more than 8 diopter (D) of myopia. This comparative study was performed on 23 eyes under treatment with Artiflex (group A) and 23 eyes under treatment with PRK-MMC (group B). Artiflex phakic IOL (Ophtec BV) was used in group A, and the VISX STAR S4 Excimer Laser (Abbott) was used for PRK-MMC in group B. The safety index was 1.11 ± 0.23 and 1.05 ± 0.25 (P = 0.100) and the efficacy index was 1.02 ± 0.11 and 0.98 ± 0.10 (P = 0.266) in group A and B, respectively. At 1 year after surgery, the manifest refraction spherical equivalent was -0.17 ± 1.18 and -0.25 ± 0.18 D in group A and B, respectively (P = 0.471). Mesopic CS showed no significant difference between the two groups in any spatial frequency. Total coma was 0.24 ± 0.17 and 0.67 ± 0.40 μm (P < 0.001), spherical aberration was -0.11 ± 0.11 and 0.41 ± 0.18 μm (P < 0.001), and RMS HOAT was 0.50 ± 0.20 and 0.96 ± 0.45 μm (P<0.001) in group A and B, respectively. Phakic IOL implantation was better than PRK-MMC in the correction of high myopia in terms of visual quality, but the two methods had no difference with regard to visual acuity. Therefore, PRK-MMC can be used when the anterior chamber depth is a limiting factor in the implantation of phakic IOLs.

  2. [Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

    PubMed

    Mester, U; Heinen, S; Kaymak, H

    2010-09-01

    Aspheric intraocular lenses (IOLs) aim to improve visual function and particularly contrast vision by neutralizing spherical aberration. One drawback of such IOLs is the enhanced sensitivity to decentration and tilt, which can deteriorate image quality. A total of 30 patients who received bilateral phacoemulsification before implantation of the aspheric lens FY-60AD (Hoya) were included in a prospective study. In 25 of the patients (50 eyes) the following parameters could be assessed 3 months after surgery: visual acuity, refraction, contrast sensitivity, pupil size, wavefront errors and decentration and tilt using a newly developed device. The functional results were very satisfying and comparable to results gained with other aspheric IOLs. The mean refraction was sph + 0.1 D (±0.7 D) and cyl 0.6 D (±0.8 D). The spherical equivalent was −0.2 D (±0.6 D). Wavefront measurements revealed a good compensation of the corneal spherical aberration but vertical and horizontal coma also showed opposing values in the cornea and IOL. The assessment of the lens position using the Purkinje meter demonstrated uncritical amounts of decentration and tilt. The mean amount of decentration was 0.2 mm±0.2 mm in the horizontal and vertical directions. The mean amount of tilt was 4.0±2.1° in horizontal and 3.0±2.5° in vertical directions. In a normal dioptric power range the aspheric IOL FY-60AD compensates the corneal spherical aberration very well with only minimal decentration. The slight tilt is symmetrical in both eyes and corresponds to the position of the crystalline lens in young eyes. This may contribute to our findings of compensated corneal coma.

  3. Quality of image of grating target placed in vitreous of isolated pig eyes photographed through different implanted multifocal intraocular lenses.

    PubMed

    Inoue, Makoto; Noda, Toru; Ohnuma, Kazuhiko; Bissen-Miyajima, Hiroko; Hirakata, Akito

    2011-11-01

    To determine the quality of the image of a grating target placed in the vitreous of isolated pig eyes and photographed through implanted refractive and diffractive multifocal intraocular lenses (IOL). Refractive multifocal (NXG1, PY60MV), diffractive multifocal (ZM900, SA60D3) and monofocal (SA60AT, ZA9003) IOL were implanted in the capsular bag of isolated pig eyes. A grating target was placed in the vitreous and photographed through a flat or a wide-field viewing contact lens. The contrast of the grating targets of different spatial frequencies was measured. With the flat corneal contact lens, the gratings appeared clear and not distorted when viewed through the optics of the NXG1 and PY60MV for far vision but were distorted with reduced contrast when viewed through the optical zone for near vision. The images through the diffractive zone of the ZM900 and SA60D3 were more defocused than with the monofocal IOL (p < 0.005). Ghost images oriented centrifugally of the original image were seen with the ZM900 resulting in lower contrast at higher spatial frequencies than with the SA60D3 with less defocused images only in the central area. With the wide-field viewing contact lens, the images were less defocused and the contrast was comparable to both refractive and diffractive multifocal IOL. Both refractive and diffractive multifocal IOL reduced the contrast of the retinal image when viewed through a flat corneal contact lens but less defocused when viewed through a wide-field viewing contact lens. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  4. Quality of image of grating target placed in model of human eye with corneal aberrations as observed through multifocal intraocular lenses.

    PubMed

    Inoue, Makoto; Noda, Toru; Mihashi, Toshifumi; Ohnuma, Kazuhiko; Bissen-Miyajima, Hiroko; Hirakata, Akito

    2011-04-01

    To evaluate the quality of the image of a grating target placed in a model eye viewed through multifocal intraocular lenses (IOLs). Laboratory investigation. Refractive (NXG1 or PY60MV) or diffractive (ZM900 or SA60D3) multifocal IOLs were placed in a fluid-filled model eye with human corneal aberrations. A United States Air Force resolution target was placed on the posterior surface of the model eye. A flat contact lens or a wide-field contact lens was placed on the cornea. The contrasts of the gratings were evaluated under endoillumination and compared to those obtained through a monofocal IOL. The grating images were clear when viewed through the flat contact lens and through the central far-vision zone of the NXG1 and PY60MV, although those through the near-vision zone were blurred and doubled. The images observed through the central area of the ZM900 with flat contact lens were slightly defocused but the images in the periphery were very blurred. The contrast decreased significantly in low frequencies (P<.001). The images observed through the central diffractive zone of the SA60D3 were slightly blurred, although the images in the periphery were clearer than that of the ZM900. The images were less blurred in all of the refractive and diffractive IOLs with the wide-field contact lens. Refractive and diffractive multifocal IOLs blur the grating target but less with the wide-angle viewing system. The peripheral multifocal optical zone may be more influential on the quality of the images with contact lens system. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of intraocular lens without conjunctival dissection in managing lens complications.

    PubMed

    Yeung, Ling; Wang, Nan-Kai; Wu, Wei-Chi; Chen, Kuan-Jen

    2018-04-23

    To evaluate the safety and efficacy of combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of intraocular lens (IOL) without conjunctival dissection. A retrospective study in Chang Gung Memorial Hospital, Keelung and Taoyuan, Taiwan. Patients receiving combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of IOL without conjunctival dissection were enrolled. The ocular findings, causes of lens complication, surgical procedures, type of IOL used, and complications were documented. We included 40 eyes from 39 patients (27 male, 12 female) with a mean age of 59.5 [standard deviation (±) 14.8] years old. The mean follow-up duration was 6.8 ± 5.4 months. The cause of lens complications was ocular trauma in 24 (60%) eyes, cataract surgery complications in 11 (28%) eyes, and spontaneous subluxation of crystalline lens in 5 (13%) eyes. The overall best corrected visual acuity (BCVA) (logMAR) improved from 1.359 ± 0.735 to 0.514 ± 0.582 (p < 0.001). The BCVA also improved significantly in each group with different causes of lens complications. Preoperative BCVA was the only factor associated with the postoperative visual outcome (p = 0.008). Most surgery-related complications were self-limited, including mild vitreous hemorrhage (5%), microhyphema (5%), transient elevated intraocular pressure (3%), and transient hypotony (3%). Cystoid macular edema and IOL decentration was found in 3 (8%) eyes and 1 (3%) eye respectively. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of IOL without conjunctival dissection is effective and safe in managing a wide variety of lens complications, with good postoperative comfort and visual recovery. Retrospective study, not applicable.

  6. Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism.

    PubMed

    Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon; Kim, Tae Im

    2016-11-01

    To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00-4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes.

  7. [The effect of yellow filter intraocular lens on the macula after cataract phacoemulsification in patients with age macular degeneration].

    PubMed

    Shpak, A A; Maliugin, B É; Fadeeva, T V

    2012-01-01

    Macula changes diagnosed with optical coherence tomography (OCT) within a year after cataract phacoemulsification (PE) with intraocular lens implantation with and without yellow filter are presented. 32 patients (36 eyes) with early stages of age macular degeneration (AMD) were included into the experimental group and 35 patients (36 eyes) served as controls. IOLs with yellow filter were implanted in 21 eyes, and in 15 cases IOLs without filter were used in each group. According to OCT data thickening of fovea and increasing of macula volume developed within 6 months after cataract PE. Implantation of yellow filter IOLs reduced the intensity of these changes after surgery in patients with AMD. The progression of early AMD into advanced stages within a year after PE was not observed.

  8. Scleral fixation of one piece intraocular lens by injector implantation

    PubMed Central

    Can, Ertuğrul; Başaran, Reşat; Gül, Adem; Birinci, Hakkı

    2014-01-01

    Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized. PMID:25230961

  9. Intraocular lens scaffold technique to prevent posterior capsule rupture in cases of Morgagnian cataract.

    PubMed

    Parkash, Rohit Om; Mahajan, Shruti; Parkash, Tushya Om; Nayak, Vittal

    2017-01-01

    We describe a technique for performing safe phacoemulsification of a Morgagnian cataract using the intraocular lens (IOL) scaffold. An IOL scaffold has been used in cases in which posterior capsule rupture has occurred, leaving nonemulsified nuclear pieces. The scaffold provides a barrier that prevents the nuclear fragments from falling posteriorly into the vitreous cavity. Our technique uses the IOL as a scaffold to prevent the vulnerable posterior capsule from rupturing during nuclear emulsification in Morgagnian cataract. The technique prevents rupture of the floppy posterior capsule by providing a constant support to it. The scaffold provides stable inflation of the capsular bag and prevents inadvertent emulsification. Concurrently, it prevents dehiscence of weak zonular fibers by minimizing the stress on the zonular apparatus. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Light distribution in diffractive multifocal optics and its optimization.

    PubMed

    Portney, Valdemar

    2011-11-01

    To expand a geometrical model of diffraction efficiency and its interpretation to the multifocal optic and to introduce formulas for analysis of far and near light distribution and their application to multifocal intraocular lenses (IOLs) and to diffraction efficiency optimization. Medical device consulting firm, Newport Coast, California, USA. Experimental study. Application of a geometrical model to the kinoform (single focus diffractive optical element) was expanded to a multifocal optic to produce analytical definitions of light split between far and near images and light loss to other diffraction orders. The geometrical model gave a simple interpretation of light split in a diffractive multifocal IOL. An analytical definition of light split between far, near, and light loss was introduced as curve fitting formulas. Several examples of application to common multifocal diffractive IOLs were developed; for example, to light-split change with wavelength. The analytical definition of diffraction efficiency may assist in optimization of multifocal diffractive optics that minimize light loss. Formulas for analysis of light split between different foci of multifocal diffractive IOLs are useful in interpreting diffraction efficiency dependence on physical characteristics, such as blaze heights of the diffractive grooves and wavelength of light, as well as for optimizing multifocal diffractive optics. Disclosure is found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Experimental characterization of the imaging properties of multifocal intraocular lenses

    NASA Astrophysics Data System (ADS)

    Gobbi, Pier Giorgio; Fasce, Francesco; Bozza, Stefano; Brancato, Rosario

    2003-07-01

    Many different types of intraocular lenses (IOL) are currently available for implantation, both as crystalline lens replacements and as phakic refractive elements. Their optical design is increasingly sophisticated, including aspherical surface profiles and multi-zone multifocal structures, however a quantitative and comparative characterization of their imaging properties is lacking. Also a qualitative visualization of their properties would be very useful for patients in the lens choice process. To this end an experimental eye model has been developed to allow for simulated in-vivo testing of IOLs. The model cornea is made of PMMA with a dioptric power of 43 D, and it has an aspherical profile designed to minimize spherical aberration across the visible spectrum. The eye model has a variable iris and a mechanical support to accomodate IOLs, immersed in physiological solution. The eye length is variable and the retina is replaced by a glass plate. The image formed on this "retina" is optically conjugated to a CCD camera, with a suitable magnification in order to mimic the human fovea resolution, and displayed onto a monitor. With such an opto-mechanical eye model, two types of images have been used to characterize IOLs: letter charts and variable contrast gratings, in order to directly simulate human visual acuity and contrast sensitivity.

  12. The relationship between the retinal image quality and the refractive index of defects arising in IOL: numerical analysis

    NASA Astrophysics Data System (ADS)

    Geniusz, Malwina

    2017-09-01

    The best treatment for cataract patients, which allows to restore clear vision is implanting an artificial intraocular lens (IOL). The image quality of the lens has a significant impact on the quality of patient's vision. After a long exposure the implant to aqueous environment some defects appear in the artificial lenses. The defects generated in the IOL have different refractive indices. For example, glistening phenomenon is based on light scattering on the oval microvacuoles filled with an aqueous humor which refractive index value is about 1.34. Calcium deposits are another example of lens defects and they can be characterized by the refractive index 1.63. In the presented studies it was calculated how the difference between the refractive indices of the defect and the refractive index of the lens material affects the quality of image. The OpticStudio Professional program (from Radiant Zemax, LLC) was used for the construction of the numerical model of the eye with IOL and to calculate the characteristics of the retinal image. Retinal image quality was described in such characteristics as Point Spread Function (PSF) and the Optical Transfer Function with amplitude and phase. The results show a strong correlation between the refractive indices difference and retinal image quality.

  13. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    NASA Astrophysics Data System (ADS)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  14. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients

    PubMed Central

    Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng

    2015-01-01

    AIM To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. METHODS Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. RESULTS There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. CONCLUSION For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention. PMID:26309870

  15. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients.

    PubMed

    Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng

    2015-01-01

    To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention.

  16. Micro-Raman analysis of glisterings in intraocular lenses

    NASA Astrophysics Data System (ADS)

    Rusciano, G.; Martinez, A.; Pesce, G.; Zito, G.; Sasso, A.

    2017-06-01

    The phenomenon of inclusions or microvacuoles in intraocular lenses (IOL), often referred to glistenings due to their appearance when visualized in slit-lamp exams, is main cause of decreased visual in people after IOL implantation. For this reason, there is a huge request by the market of new polymers able to reduce, or even eliminate, the formation of such microvacuoles. In such frame, the use of advanced optical techniques, able to provide a deeper insight on the glistering formation, is strongly required. In particular, Raman spectroscopy (RS) is ideally suited for the analysis of polymers, due to its well-know sensitivity to highly polarizable chemical groups, commonly found in the polymer chains backbones. Moreover, the combination of RS with optical microscopy (Raman micro-spectroscopy) paves the way for real, information-rich chemical mapping of polymeric materials (Raman imaging). In this paper, we analyze the formation of microvacuoles in IOLs following a thermal treatment. In particular, we performed a chemical mapping of a single microvacuole, which allowed us to infer on its effective chemical composition. In order to investigate on the reversibility of glistenings formation, this analysis was repeated as function of time after thermal treatment, in different IOL environments. It turns out that this phenomenon is partially reversible, with an almost complete disappearance of microvacuoles in a dry environment.

  17. [Comparison of surface light scattering of acrylic intraocular lenses made by lathe-cutting and cast-molding methods--long-term observation and experimental study].

    PubMed

    Nishihara, Hitoshi; Ayaki, Masahiko; Watanabe, Tomiko; Ohnishi, Takeo; Kageyama, Toshiyuki; Yaguchi, Shigeo

    2004-03-01

    To compare the long-term clinical and experimental results of soft acrylic intraocular lenses(IOLs) manufactured by the lathe-cut(LC) method and by the cast-molding(CM) method. This was a retrospective study of 20 patients(22 eyes) who were examined in a 5- and 7-year follow-up study. Sixteen eyes were implanted with polyacrylic IOLs manufactured by the LC method and 6 eyes were implanted with polyacrylic IOLs manufactured by the CM method. Postoperative measurements included best corrected visual acuity, contrast sensitivity, biomicroscopic examination, and Scheimpflug slit-lamp images to evaluate surface light scattering. Scanning electron microscopy and three-dimensional surface analysis were conducted. At 7 years, the mean visual acuity was 1.08 +/- 0.24 (mean +/- standard deviation) in the LC group and 1.22 +/- 0.27 in the CM group. Surface light-seatter was 12.0 +/- 4.0 computer compatible tapes(CCT) in the LC group and 37.4 +/- 5.4 CCT in the CM group. Mean surface roughness was 0.70 +/- 0.07 nm in the LC group and 6.16 +/- 0.97 nm in the CM group. Acrylic IOLs manufactured by the LC method are more stable in long-termuse.

  18. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    PubMed

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1-4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  19. Macroeconomic landscape of refractive surgery in the United States.

    PubMed

    Corcoran, Kevin J

    2015-07-01

    This review examines the economic history of refractive surgery and the decline of laser-assisted in-situ keratomileusis (LASIK) in the USA, and the emergence of refractive cataract surgery as an area of growth. Since it peaked in 2007 at 1.4 million procedures per year, LASIK has declined 50% in the USA, whereas refractive cataract surgery, including presbyopia-correcting intraocular lenses (IOLs), astigmatism-correcting IOLs, and femtosecond laser-assisted cataract surgery, has grown to 350 000 procedures per year, beginning in 2003. Patients are price-sensitive and responsive to publicity (good or bad) about refractive surgery and refractive cataract surgery. LASIK's decline has been partially offset by the emergence of refractive cataract surgery. About 11% of all cataract surgery in the USA involves presbyopia-correcting IOLs, astigmatism-correcting IOLs, or a femtosecond laser. From the surgeon's perspective, there are high barriers to entry into the marketplace for refractive surgery and refractive cataract surgery due to the high capital cost of excimer and femtosecond lasers, the high skill level required to deliver spectacular results to demanding patients who pay out of pocket, and the necessity to perform a high volume of surgeries to satisfy both of these requirements. Probably, less than 7% of US cataract surgeons can readily meet all of these requirements.

  20. Bounds on quantum collapse models from matter-wave interferometry: calculational details

    NASA Astrophysics Data System (ADS)

    Toroš, Marko; Bassi, Angelo

    2018-03-01

    We present a simple derivation of the interference pattern in matter-wave interferometry predicted by a class of quantum master equations. We apply the obtained formulae to the following collapse models: the Ghirardi-Rimini-Weber (GRW) model, the continuous spontaneous localization (CSL) model together with its dissipative (dCSL) and non-Markovian generalizations (cCSL), the quantum mechanics with universal position localization (QMUPL), and the Diósi-Penrose (DP) model. We discuss the separability of the dynamics of the collapse models along the three spatial directions, the validity of the paraxial approximation, and the amplification mechanism. We obtain analytical expressions both in the far field and near field limits. These results agree with those already derived in the Wigner function formalism. We compare the theoretical predictions with the experimental data from two recent matter-wave experiments: the 2012 far-field experiment of Juffmann T et al (2012 Nat. Nanotechnol. 7 297-300) and the 2013 Kapitza-Dirac-Talbot-Lau (KDTL) near-field experiment of Eibenberger et al (2013 Phys. Chem. Chem. Phys. 15 14696-700). We show the region of the parameter space for each collapse model that is excluded by these experiments. We show that matter-wave experiments provide model-insensitive bounds that are valid for a wide family of dissipative and non-Markovian generalizations.

  1. Multifocal versus monofocal intraocular lenses after cataract extraction.

    PubMed

    de Silva, Samantha R; Evans, Jennifer R; Kirthi, Varo; Ziaei, Mohammed; Leyland, Martin

    2016-12-12

    Good unaided distance visual acuity (VA) is now a realistic expectation following cataract surgery and intraocular lens (IOL) implantation. Near vision, however, still requires additional refractive power, usually in the form of reading glasses. Multiple optic (multifocal) IOLs are available which claim to allow good vision at a range of distances. It is unclear whether this benefit outweighs the optical compromises inherent in multifocal IOLs. To assess the visual effects of multifocal IOLs in comparison with the current standard treatment of monofocal lens implantation. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2016), Embase (January 1980 to June 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 June 2016. All randomised controlled trials comparing a multifocal IOL of any type with a monofocal IOL as control were included. Both unilateral and bilateral implantation trials were included. We also considered trials comparing multifocal IOLs with "monovision" whereby one eye is corrected for distance vision and one eye corrected for near vision. We used standard methodological procedures expected by Cochrane. We assessed the 'certainty' of the evidence using GRADE. We found 20 eligible trials that enrolled 2230 people with data available on 2061 people (3194 eyes). These trials were conducted in Europe (13), China (three), USA (one), Middle East (one), India (one) and one multicentre study in Europe and the USA. Most of these trials compared multifocal with monofocal lenses; two trials compared multifocal lenses with monovision. There was considerable variety in the make and model of lenses implanted. Overall we considered the trials at risk of performance and detection bias because it was difficult to mask participants and outcome assessors. It was also difficult to assess the role of reporting bias.There was moderate-certainty evidence that the distance acuity achieved with multifocal lenses was not different to that achieved with monofocal lenses (unaided VA worse than 6/6: pooled RR 0.96, 95% confidence interval (CI) 0.89 to 1.03; eyes = 682; studies = 8). People receiving multifocal lenses may achieve better near vision (RR for unaided near VA worse than J3/J4 was 0.20, 95% CI 0.07 to 0.58; eyes = 782; studies = 8). We judged this to be low-certainty evidence because of risk of bias in the included studies and high heterogeneity (I 2 = 93%) although all included studies favoured multifocal lenses with respect to this outcome.People receiving multifocal lenses may be less spectacle dependent (RR 0.63, 95% CI 0.55 to 0.73; eyes = 1000; studies = 10). We judged this to be low-certainty evidence because of risk of bias and evidence of publication bias (skewed funnel plot). There was also high heterogeneity (I 2 = 67%) but all studies favoured multifocal lenses. We did not additionally downgrade for this.Adverse subjective visual phenomena were more prevalent and more troublesome in participants with a multifocal IOL compared with monofocals (RR for glare 1.41, 95% CI 1.03 to 1.93; eyes = 544; studies = 7, low-certainty evidence and RR for haloes 3.58, 95% CI 1.99 to 6.46; eyes = 662; studies = 7; moderate-certainty evidence).Two studies compared multifocal lenses with monovision. There was no evidence for any important differences in distance VA between the groups (mean difference (MD) 0.02 logMAR, 95% CI -0.02 to 0.06; eyes = 186; studies = 1), unaided intermediate VA (MD 0.07 logMAR, 95% CI 0.04 to 0.10; eyes = 181; studies = 1) and unaided near VA (MD -0.04, 95% CI -0.08 to 0.00; eyes = 186; studies = 1) compared with people receiving monovision. People receiving multifocal lenses were less likely to be spectacle dependent (RR 0.40, 95% CI 0.30 to 0.53; eyes = 262; studies = 2) but more likely to report problems with glare (RR 1.41, 95% CI 1.14 to 1.73; eyes = 187; studies = 1) compared with people receiving monovision. In one study, the investigators noted that more people in the multifocal group underwent IOL exchange in the first year after surgery (6 participants with multifocal vs 0 participants with monovision). Multifocal IOLs are effective at improving near vision relative to monofocal IOLs although there is uncertainty as to the size of the effect. Whether that improvement outweighs the adverse effects of multifocal IOLs, such as glare and haloes, will vary between people. Motivation to achieve spectacle independence is likely to be the deciding factor.

  2. Comparison of different wavefront measurement setups to judge the position tolerance of intraocular lenses in a model eye

    NASA Astrophysics Data System (ADS)

    Traxler, Lukas; Reutterer, Bernd; Bayer, Natascha; Drauschke, Andreas

    2017-04-01

    To treat cataract intraocular lenses (IOLs) are used to replace the clouded human eye lens. Due to postoperative healing processes the IOL can displace within the eye, which can lead to deteriorated quality of vision. To test and characterize these effect an IOL can be embedded into a model of the humane eye. One informative measure are wavefront aberrations. In this paper three different setups, the typical double-pass configuration (DP), a single-pass (SP1) where the measured light travels in the same direction as in DP and a single-pass (SP2) with reversed direction, are investigated. All three setups correctly measure the aberrations of the eye, where SP1 is found to be the simplest to set up and align. Because of the lowest complexity it is the proposed method for wavefront measurement in model eyes.

  3. Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus.

    PubMed

    Schedin, Staffan; Hallberg, Per; Behndig, Anders

    2016-01-20

    We propose a numerical three-dimensional (3D) ray-tracing model for the analysis of advanced corneal refractive errors. The 3D modeling was based on measured corneal elevation data by means of Scheimpflug photography. A mathematical description of the measured corneal surfaces from a keratoconus (KC) patient was used for the 3D ray tracing, based on Snell's law of refraction. A model of a commercial intraocular lens (IOL) was included in the analysis. By modifying the posterior IOL surface, it was shown that the imaging quality could be significantly improved. The RMS values were reduced by approximately 50% close to the retina, both for on- and off-axis geometries. The 3D ray-tracing model can constitute a basis for simulation of customized IOLs that are able to correct the advanced, irregular refractive errors in KC.

  4. Pigment dispersion and chronic intraocular pressure elevation after sulcus placement of 3-piece acrylic intraocular lens.

    PubMed

    Almond, M Camille; Wu, Michael C; Chen, Philip P

    2009-12-01

    A 55-year-old man had phacoemulsification and implantation of a 3-piece acrylic intraocular lens (IOL) (AcrySof MA60AC) in the right eye. One month postoperatively, the intraocular pressure (IOP) was 48 mm Hg and peripheral transillumination defects were noted in the iris circumferentially, with the IOL optic edge visible as a silhouette. Gonioscopy showed dense pigmentation of the trabecular meshwork in the right eye, but in the left eye, only mild trabecular meshwork pigment was seen, along with a concave peripheral iris insertion. At 21 months, the right eye required 3 medications for IOP control. While pigment dispersion has been widely reported after placement of 1-piece acrylic IOLs in the ciliary sulcus, we conclude that in susceptible individuals with a concave peripheral iris insertion, pigment dispersion can occur with sulcus placement of a 3-piece acrylic model despite its thinner optic and angulated haptics.

  5. Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

    PubMed Central

    Can, Ertuğrul; Koçak, Nurullah; Yücel, Özlem Eşki; Gül, Adem; Öztürk, Hilal Eser; Sayın, Osman

    2016-01-01

    Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes. PMID:27050346

  6. Trends in refractive surgery at an academic center: 2007-2009.

    PubMed

    Kuo, Irene C

    2011-05-14

    The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0.05). The proportions of types of procedure changed, with an increase in the proportion of PRK between 2007 and 2009 (p = 0.02). The mean age of patients did not change [42.4 ± 14.4 (standard deviation) years in 2007 vs. 39.6 ± 14.5 years in 2009; p = 0.4]. Astigmatism-correcting IOL and presbyopia-correcting IOL volumes increased 15-fold and three-fold, respectively, between 2007 and 2009. Volume of excimer laser refractive surgery decreased by at least 30% between 2007 and 2009. No significant change in mean age or in the distribution of refractive error was seen, although the proportion of high myopes decreased between summer quarters of 2007 and 2009. PRK gained as a proportion of total cases. Premium IOL volume increased, but still comprised a very small proportion of total IOL volume.

  7. Trends in refractive surgery at an academic center: 2007-2009

    PubMed Central

    2011-01-01

    Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Methods Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Results Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0.05). The proportions of types of procedure changed, with an increase in the proportion of PRK between 2007 and 2009 (p = 0.02). The mean age of patients did not change [42.4 ± 14.4 (standard deviation) years in 2007 vs. 39.6 ± 14.5 years in 2009; p = 0.4]. Astigmatism-correcting IOL and presbyopia-correcting IOL volumes increased 15-fold and three-fold, respectively, between 2007 and 2009. Conclusions Volume of excimer laser refractive surgery decreased by at least 30% between 2007 and 2009. No significant change in mean age or in the distribution of refractive error was seen, although the proportion of high myopes decreased between summer quarters of 2007 and 2009. PRK gained as a proportion of total cases. Premium IOL volume increased, but still comprised a very small proportion of total IOL volume. PMID:21569564

  8. Maintenance of Time and Frequency in the DSN Using the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Clements, P. A.; Kirk, A.; Borutzki, S. E.

    1985-01-01

    The Deep Space Network must maintain time and frequency within specified limits in order to accurately track the spacecraft engaged in deep space exploration. The DSN has three tracking complexes, located approximately equidistantly around the Earth. Various methods are used to coordinate the clocks among the three complexes. These methods include Loran-C, TV Line 10, very long baseline interferometry (VLBI), and the Global Positioning System (GPS). The GPS is becoming increasingly important because of the accuracy, precision, and rapid availability of the data; GPS receivers have been installed at each of the DSN complexes and are used to obtain daily time offsets between the master clock at each site and UTC(USNO/NBS). Calculations are made to obtain frequency offsets and Allan variances. These data are analyzed and used to monitor the performance of the hydrogen masers that provide the reference frequencies for the DSN frequency and timing system (DFT). A brief history of the GPS timing receivers in the DSN, a description of the data and information flow, data on the performance of the DSN master clocks and GPS measurement system, and a description of hydrogen maser frequency steering using these data are presented.

  9. Effect of low molecular weight heparin (enoxaparin) on congenital cataract surgery.

    PubMed

    Caça, Ihsan; Sahin, Alparslan; Cingü, Abdullah Kürsat; Ari, Seyhmus; Alakuş, Fuat; Cinar, Yasin

    2012-01-01

    To assess the efficacy of intracameral enoxaparin (a low-molecular-weight heparin) infusion, in variable doses on postoperative inflammatory response in congenital cataract surgery. It is a prospective, randomized controlled trial. Eighty eyes of 53 children with congenital cataract were enrolled in this study. Every eye had primary posterior capsulorrhexis and intraocular lens (IOL) implantation after lens aspiration. The eyes were divided into 4 equal groups. In group 1 balanced salt solution (BSS) without enoxaparin was used as an irrigation solution. Whereas in group 2, 3 and 4, 40mg, 20mg and 10mg enoxaparin in 500mL BSS was used respectively. The inflammatory response in the anterior chamber was compared among the groups with slit-lamp biomicroscopy. The mean follow-up period was (17.75±3.95) months in group 1, (18.00±5.15) months in group 2, (19.20±5.47) months in group 3 and (18.65±5.16) months in group 4. Mean number of inflammatory cells in the anterior chamber in group 1 was significantly higher than that of group 2, 3, 4 (P<0.001). There was fibrin formation in the anterior chambers of 3 eyes in group 1 and one eye in group 4. There was synechiae formation in 3 eyes of group 1 and one eye of group 4. There was no significant difference among the groups by means of fibrin or synechiae formation (P>0.05). There were IOL precipitates in 4 eyes of group 1 and 2 eyes of group 4. IOL precipitate formation was significantly higher in group 1 than that of group 2 and 3 in which there was no IOL precipitate (P=0.048). There was IOL subluxation in only one eye of group 1, 3 and 4 while no subluxation was observed in group 2 (P>0.05). There was no statistically significant difference detected about IOL subluxation occurance in all 4 groups (P>0.05). Complications of cataract surgery in congenital cataract patients associated with postoperative inflammatory response found to be decreased with the use of enoxaparin in intraocular infusion solutions. Furthermore according to our results the anti-inflammatory effect of enoxaparin was dose dependant.

  10. Effect of low molecular weight heparin (enoxaparin) on congenital cataract surgery

    PubMed Central

    Çaça, Ihsan; Şahin, Alparslan; Cingü, Abdullah Kürsat; Ari, Şeyhmus; Alakuş, Fuat; Çinar, Yasin

    2012-01-01

    AIM To assess the efficacy of intracameral enoxaparin (a low-molecular-weight heparin) infusion, in variable doses on postoperative inflammatory response in congenital cataract surgery. METHODS It is a prospective, randomized controlled trial. Eighty eyes of 53 children with congenital cataract were enrolled in this study. Every eye had primary posterior capsulorrhexis and intraocular lens (IOL) implantation after lens aspiration. The eyes were divided into 4 equal groups. In group 1 balanced salt solution (BSS) without enoxaparin was used as an irrigation solution. Whereas in group 2, 3 and 4, 40mg, 20mg and 10mg enoxaparin in 500mL BSS was used respectively. The inflammatory response in the anterior chamber was compared among the groups with slit-lamp biomicroscopy. RESULTS The mean follow-up period was (17.75±3.95) months in group 1, (18.00±5.15) months in group 2, (19.20±5.47) months in group 3 and (18.65±5.16) months in group 4. Mean number of inflammatory cells in the anterior chamber in group 1 was significantly higher than that of group 2, 3, 4 (P<0.001). There was fibrin formation in the anterior chambers of 3 eyes in group 1 and one eye in group 4. There was synechiae formation in 3 eyes of group 1 and one eye of group 4. There was no significant difference among the groups by means of fibrin or synechiae formation (P>0.05). There were IOL precipitates in 4 eyes of group 1 and 2 eyes of group 4. IOL precipitate formation was significantly higher in group 1 than that of group 2 and 3 in which there was no IOL precipitate (P=0.048). There was IOL subluxation in only one eye of group 1, 3 and 4 while no subluxation was observed in group 2 (P>0.05). There was no statistically significant difference detected about IOL subluxation occurance in all 4 groups (P>0.05). CONCLUSION Complications of cataract surgery in congenital cataract patients associated with postoperative inflammatory response found to be decreased with the use of enoxaparin in intraocular infusion solutions. Furthermore according to our results the anti-inflammatory effect of enoxaparin was dose dependant. PMID:23166871

  11. Surgical management of spontaneous in-the-bag intraocular lens and capsular tension ring complex dislocation.

    PubMed

    Gunenc, Uzeyir; Kocak, Nilufer; Ozturk, A Taylan; Arikan, Gul

    2014-08-01

    We describe a technique to manage late spontaneous intraocular lens (IOL) and capsular tension ring (CTR) dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fixed to the pars plana at both 3 and 9 o'clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and effective surgical option for such cases.

  12. Simulation of air-bag impact on an eye with transsclerally fixated posterior chamber intraocular lens using finite element analysis.

    PubMed

    Uchio, Eiichi; Kadonosono, Kazuaki; Matsuoka, Yasuhiro; Goto, Satoru

    2004-02-01

    To determine the physical and mechanical conditions of an impacting air bag that would rupture an eye with a transsclerally fixated posterior chamber intraocular lens (IOL). Numerical simulation study on a computer. Simulations in a model human eye were performed with a computer using the finite element analysis program PAM-CRASH (Nihon ESI). The air bag was set to impact the surface of an eye with a transsclerally fixated posterior chamber IOL at various velocities. The tensile force limit of a 10-1 polypropylene suture was assumed to be 0.16 N, which is specified in the U.S. Pharmacopeia XXII. At the lowest velocity of 20.0 m/s, 10-0 polypropylene sutures were not likely to break. Sutures fixating the IOL might break and a corneoscleral incision was likely to open after 0.3 second at the medium impacting velocity (30 m/s). Suture rupture was very likely at the highest velocity (40 m/s) since the tensile force on the sutures continuously exceeded the breaking force after the impact. In an eye with a transsclerally fixated posterior chamber IOL, severe ocular trauma can be caused by an air bag at high velocity. Small individuals such as elderly women are at greater risk for air-bag ocular injury. Further research on modifying air-bag design and deployment is important to minimize the risk for ocular injury.

  13. [Posterior capsule opacification, capsular bag distension syndrome, and anterior capsular phimosis: A retrospective cohort study].

    PubMed

    González-Martín-Moro, J; González-López, J J; Gómez-Sanz, F; Zarallo-Gallardo, J; Cobo-Soriano, R

    2015-02-01

    To determine the incidence and the risk factors involved in the development of the three main postoperative capsular complications: posterior capsule opacification (PCO), capsular bag distension syndrome (CBDS), and anterior capsular phimosis syndrome (ACP). A retrospective cohort study was conducted on 801 patients submitted to cataract surgery in the ophthalmology unit of Hospital del Henares (Madrid) from March 2, 2009 to February 28, 2010. Computerized clinical charts were reviewed during July 2012. PCO was studied using the Kaplan-Meier method (log rank test). A total of 167 patients developed PCO. No association could be demonstrated between PCO and age, sex, diabetes mellitus, phaco technique, IOL model, tamsulosin intake, glaucoma, and age-related macular degeneration. Three patients developed CBDS, all of them have received and Akreos Adapt AO(®) (Bausch & Lomb). Two of them were young men who had received surgery for posterior subcapsular cataracts. Three patients developed ACP, 2 of whom had received a MicroSlim(®) IOL (PhysIOL). No association was found between PCO and any of the studied variables. Male gender, young age, subcapsular cataract and large non-angulated lens such as Akreos Adapt AO(®) could be associated with CBDS. ACP could be more frequent when microincision IOLs (like MicroSlim(®)) are implanted. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Reading ability with pseudophakic monovision and with refractive multifocal intraocular lenses: comparative study.

    PubMed

    Ito, Misae; Shimizu, Kimiya

    2009-09-01

    To the compare the reading ability after bilateral cataract surgery in patients who had pseudophakic monovision achieved by monofocal intraocular lens (IOL) implantation and patients who had refractive multifocal IOL implantation. Department of Ophthalmology, Kitasato University Hospital, Kanagawa, Japan. This study evaluated patients who had bilateral cataract surgery using the monovision method with monofocal IOL implantation to correct presbyopia (monovision group) or who had bilateral cataract surgery with refractive multifocal IOL implantation (multifocal group). In the monovision group, the dominant eye was corrected for distance vision and the nondominant eye for near vision. The maximum reading speed, critical character size, and reading acuity were measured binocularly without refractive correction using MNREAD-J acuity charts. The monovision group comprised 38 patients and the multifocal group, 22 patients. The mean maximum reading speed was 350.5 characters per minute (cpm) +/- 62.3 (SD) in the monovision group and 355.0 +/- 53.3 cpm in the multifocal group; the difference was not statistically significant. The mean critical character size was 0.24 +/- 0.12 logMAR and 0.40 +/- 0.16 logMAR, respectively (P<.05). The mean reading acuity was 0.05 +/- 0.12 logMAR and 0.19 +/- 0.11 logMAR, respectively (P<.01). The monovision group had better critical character size and reading acuity results. The monovision method group had better reading ability; however, careful patient selection is essential.

  15. Peripheral refraction in pseudophakic eyes measured by infrared scanning photoretinoscopy.

    PubMed

    Tabernero, Juan; Ohlendorf, Arne; Fischer, M Dominik; Bruckmann, Anna R; Schiefer, Ulrich; Schaeffel, Frank

    2012-05-01

    To obtain quantitative data of peripheral refractive errors in pseudophakic eyes including measurements up to ±45 degrees on the retina. University Eye Hospital, Tübingen, Germany. Population-based cross-sectional study. Pseudophakic and phakic subjects were measured with a purpose-built scanning photorefractor. The instrument was improved over previous versions. It permits measurement of semicontinuous peripheral profiles over the central 90-degree field of the retina at a faster speed (4 s/scan). Twenty-four pseudophakic and 43 phakic subjects were enrolled. The intraocular lenses (IOLs) induced a mean myopic shift of 2.00 diopters (D) at ±45 degrees of eccentricity in the vertical pupil meridian. Ray-tracing simulations with phakic eye and pseudophakic eye models agreed well with the experimental data. They showed that changes induced by IOLs were a consequence of an increase in astigmatism with eccentricity and a myopic shift in the spherical equivalent. The peripheral refractions in pseudophakic eyes were more myopic than in phakic eyes as a consequence of the optical design of the IOLs. Whether a more myopic refraction of approximately 2.00 D at 45 degrees has significant effects on visual performance must be tested. Perhaps there is room for improvement in the peripheral optics of IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Refractive index and its impact on pseudophakic dysphotopsia.

    PubMed

    Radmall, Bryce R; Floyd, Anne; Oakey, Zack; Olson, Randall J

    2015-01-01

    It has been shown that the biggest dissatisfier for uncomplicated cataract surgery patients is pseudophakic dysphotopsia (PD). While edge design of an intraocular lens (IOL) impacts this problem, refractive index is still controversial as to its impact. This retrospective cohort study was designed to determine the role of increasing refractive index in PD. This study was conducted at the John A. Moran Eye Center, University of Utah, USA. A retrospective chart review identified patients who received one of two hydrophobic acrylic single piece IOLs (AcrySof WF SP [SN60WF] or Tecnis SP [ZCB00]), which differed mainly by refractive index (1.55 versus 1.47). Eighty-seven patients who had received implantation of a one-piece hydrophobic acrylic IOL were enrolled. Patients were included if the surgery had been uncomplicated and took place at least a year before study participation. All eligible patients had 20/20 best corrected vision, without any disease known to impact visual quality. In addition to conducting a record review, the enrolled patients were surveyed for PD, using a modified National Eye Institute Visual Function questionnaire, as well as for overall satisfaction with visual quality. Statistical analysis demonstrated no difference between the two cohorts regarding PD, general visual function, and overall visual satisfaction. The study suggests that with the two IOLs assessed, increasing the refractive index does not increase incidence of PD or decrease overall visual satisfaction.

  17. Mini-review: Far peripheral vision.

    PubMed

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients

    PubMed Central

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-01-01

    Aim: To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Settings and Design: Retrospective, noncomparable consecutive case series study. Materials and Methods: Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Results: Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1–4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Conclusions: Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support. PMID:27146932

  19. A Retrospective Case-Control Study Evaluating the Role of Mifepristone for Induction of Labor in Women with Previous Cesarean Section.

    PubMed

    Sharma, Chanderdeep; Soni, Anjali; Soni, Pawan K; Verma, Suresh; Verma, Ashok; Gupta, Amit

    2016-10-01

    To investigate the role of "mifepristone" for induction of labor (IOL) in pregnant women with prior cesarean section (CS). In this retrospective study, all pregnant women with prior CS who received oral mifepristone (400 mg) for IOL (as per clear obstetric indications) [group 1] were compared with pregnant women with prior CS who had spontaneous onset of labor (SOL) [group 2], with respect to incidence of vaginal delivery, CS, duration of labor, and various maternal and fetal outcomes. During the study period, 72 women received mifepristone (group 1) for IOL and 346 had SOL (group 2). In group 1 after mifepristone administration, 40 (55.6 %) women had labor onset, and 24 (33.3 %) women had cervical ripening (Bishop Score ≥ 8) within 48 h. There were no statistically significant differences with respect to duration of labor (p value: 0.681), mode of delivery (i.e., normal delivery or CS-p value: 0.076 or 0.120, respectively), or maternal (blood loss or scar dehiscence/rupture uterus), or fetal outcomes (NICU admission) compared to women with previous CS with SOL (group 2). However, the need of oxytocin (p value 0.020) and dose of oxytocin requirement (p value 0.008) were more statistically significant in group 1. Mifepristone may be considered as an agent for IOL in women with prior CS.

  20. Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

    PubMed Central

    Apple, D J

    2000-01-01

    PURPOSE: To evaluate the influence of intraocular lens (IOL) material and design on the outcome of postoperative lens epithelial cell proliferation within the capsular bag after cataract surgery. METHODS: A total of 5,079 human globes containing rigid and foldable posterior chamber IOL styles commonly implanted in the United States (n = 8) were analyzed in this study. Each globe, fixated in 10% formalin, was sectioned at the equator and analyzed using the Miyake-Apple posterior technique. The study consisted of 3 parts: First, to evaluate posterior capsule opacification (PCO); the Nd:YAG laser posterior capsulotomy rate (%) was documented and plotted on a monthly basis, creating a computerized trend line for each IOL style. Second, to evaluate anterior capsule opacification (ACO); 460 globes were processed for histologic examination. Anterior capsule fibrosis was scored from 0 to III, according to the thickness of proliferative tissue/cells on the inner surface of the anterior capsule at the capsulorhexis margin. Third, interlenticular opacification (ILO) was studied by analysis of 3 pairs of acrylic piggyback lenses that had been explanted because of opacification between their optics. Each IOL pair was processed for histologic examination, and scanning electron microscopy was performed on 1 of the lenses. RESULTS: In the first study, relatively higher Nd:YAG laser posterior capsulotomy rates (19.1% to 32.8%) were noted with the 4 oldest IOL designs in this study (2 foldable lenses, 1 3-piece polymethyl methacrylate [PMMA] design, and 1 single-piece all-PMMA design). Four modern lenses, 1 acrylic lens, and 3 silicone foldable IOL designs had Nd:YAG rates ranging from 1.3% to 14.6% (P < .0001). In the second study, mean ACO scores were highest with silicone-plate lenses (1.77 +/- 0.86 and 1.28 +/- 0.77). The lowest mean score was observed with the acrylic lens (0.51 +/- 0.52; P < .0001). In study 3, the analyses of the 3 pairs of explanted acrylic piggyback lenses showed that the opacification between them (ILO) may have different forms. CONCLUSIONS: Control of postoperative intracapsular cellular proliferation is important in avoiding 3 significant clinical complications. Postoperative lens epithelial cell proliferation is involved in the pathogenesis of PCO, ACO, and ILO, the latter being a newly described form of opacification within the capsular bag related to piggyback IOL implantation. IOL material and design are important factors influencing the outcome of these complications. Images FIGURE 1 FIGURE 2A FIGURE 2B FIGURE 3 FIGURE 4A FIGURE 4B FIGURE 5A FIGURE 5B FIGURE 5C FIGURE 5D FIGURE 5E FIGURE 5F FIGURE 5G FIGURE 5H FIGURE 6 FIGURE 7 FIGURE 8A FIGURE 8B FIGURE 9A FIGURE 9B FIGURE 10A FIGURE 10B FIGURE 10C FIGURE 10D FIGURE 10E FIGURE 10F FIGURE 10G FIGURE 10H FIGURE 11A FIGURE 11B FIGURE 12 FIGURE 13A FIGURE 13B FIGURE 14A FIGURE 14B FIGURE 15A FIGURE 15B FIGURE 16A FIGURE 16B FIGURE 17A FIGURE 17B FIGURE 18A FIGURE 18B FIGURE 18C FIGURE 18D FIGURE 18E FIGURE 19 FIGURE 20 PMID:11190028

  1. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    PubMed Central

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    AIM To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. METHODS Non-comparative retrospective observational case series. Participants: 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures: visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. RESULTS The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. CONCLUSION To take early treatment of traumatic lens subluxation/dislocation in patients with secondary glaucoma by individual surgical plan based on the different eye conditions would be safe and effective, which can effectively control the intraocular pressure and restore some vision. PMID:24790868

  2. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

    PubMed

    Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A

    2017-06-01

    To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P < .05) postoperatively. The mean residual refractive cylinder was -0.36 ± 0.32 D and -0.47 ± 0.28 D in the image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Posterior capsule opacification in rabbit eyes implanted with 1-piece and 3-piece hydrophobic acrylic intraocular lenses.

    PubMed

    Werner, Liliana; Mamalis, Nick; Izak, Andrea M; Pandey, Suresh K; Davis, Brandon L; Nilson, Chistian D; Weight, Christopher; Apple, David J

    2005-04-01

    To evaluate the outcome of posterior capsule opacification (PCO) after implantation in rabbit eyes of currently available 3-piece and 1-piece hydrophobic acrylic intraocular lenses (IOLs) with square optic edges. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. The 3-piece designs evaluated were the AR40e (Advanced Medical Optics Inc.) and the MA60AC (Alcon, Inc.); the 1-piece designs were the SA60AT and the SA30AT (Alcon, Inc.). Nine lenses of each type were implanted in a randomized manner by the same surgeon in 18 Dutch Belted pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and analyses of the enucleated eyes were performed from the posterior or Miyake-Apple view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was scored from 0 to 4. The area of Soemmering's ring formation was also scored from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL anterior surface, IOL centration, fixation, and presence of striae. Results from the posterior view were complemented by histopathologic evaluation of the eyes. No statistically significant difference was found between the 4 groups of IOLs in the parameters analyzed from the posterior view. When cell ingrowth occurred with the 1-piece designs, causing peripheral and central PCO formation, it was more likely to start at the optic-haptic junctions, as observed during the clinical follow-up with slitlamp examination and confirmed by gross and histopathologic analyses of the enucleated eyes. The square, truncated optic edge is the most important IOL design feature for PCO prevention. The optic-haptic junctions of the 1-piece designs appear to be sites where the barrier effect of the truncated optic edge is less effective.

  4. A Comparative Study of Clear Corneal Phacoemulsification with Rigid IOL Versus SICS; the Preferred Surgical Technique in Low Socio-economic group Patients of Rural Areas.

    PubMed

    Devendra, Jaya; Agarwal, Smita; Singh, Pankaj Kumar

    2014-11-01

    Low socio-economic group patients from rural areas often opt for free cataract surgeries offered by charitable organisations. SICS continues to be a time tested technique for cataract removal in such patients. In recent times, camp patients are sometimes treated by clear corneal phacoemulsification with implantation of a rigid IOL, which being more cost effective is often provided for camp patients. This study was undertaken to find out which surgical technique yielded better outcomes and was more suited for high volume camp surgery. To find the better surgical option- phacoemulsification with rigid IOL or SICS, in poor patients from rural areas. A prospective randomised controlled trial of cataract patients operated by two different techniques. One hundred and twelve eyes were selected and were randomly allocated into two groups of 56 eyes each. At completion of the study, data was analysed for 52 eyes operated by clear corneal phacoemulsification and implantation of a rigid IOL, and 56 eyes operated by SICS. Unpaired t-test was used to calculate the p- value. The results were evaluated on the following criteria. The mean post-operative astigmatism at the end of four weeks - was significantly higher in phacoemulsification group as compared to SICS group The BCVA (best corrected visual acuity) at the end of four weeks - was comparable in both groups. Subjective complaints and/ or complications: In phaco group two patients required sutures and seven had striate keratitis , while none in SICS group. Complaint of irritation was similar in both groups. Surgical time- was less for SICS group as compared to phaco group. SICS by virtue of being a faster surgery with more secure wound and significantly less astigmatism is a better option in camp patients from rural areas as compared to phacoemulsification with rigid IOL.

  5. Improving induction of labour - a quality improvement project addressing Caesarean section rates and length of process in women undergoing induction of labour

    PubMed Central

    O'Dwyer, Sabrina; Raniolo, Caterina; Roper, Janice; Gupta, Manish

    2015-01-01

    Induction of labour (IOL) in maternity care is often not an area of priority in maternity services, which often results in protracted delays, a poor patient experience, and patient complaints. Caesarean section (CS) rates among women undergoing IOL at this inner city district general hospital were noted to be higher than other units nationwide. We collected pre and post-intervention data of the following outcome measures: time taken to administer prostaglandin after arrival, time taken to achieve established labour, mode of delivery, and user satisfaction scores. Our introduction of a dedicated IOL Suite, promotion of out-patient IOL, use of a single administration prostaglandin (as opposed to traditional six hourly prostaglandin), widespread staff engagement and rolling audit has resulted in positive change in the maternity unit. CS rates for women undergoing IOL have been reduced from 29% to 22% (p=0.05), time taken to administer the induction medication has decreased from 6.3h to 2.7h (p=0.0001), and out-patient induction rates have increased from 3% to 33% (p=0.001). We have achieved a reduction in the overall length of in-patient stay. We have also received positive feedback from both staff and patients. We used a bottom-up approach, engaging frontline staff in problem identification and pathway design. Our staff engagement questionnaire showed other benefits such as increased staff morale as a result. Collection of simple performance data and sharing of this in real time with staff acts as a valuable tool for acceptance of change and continuous improvement. Communicating plans to a large body of people is important in ensuring the success of an intervention. Staff showing disengagement may require specific detailed information to allay their concerns. Following initial successes, ongoing vigilance, and collection of audit data is key to sustaining any improvement. PMID:26734422

  6. A technique of experimental and numerical analysis of influence of defects in the intraocular lens on the retinal image quality

    NASA Astrophysics Data System (ADS)

    Geniusz, Malwina; ZajÄ c, Marek

    2016-09-01

    Intraocular lens (IOL) is an artificial lens implanted into the eye in order to restore correct vision after the removal of natural lens cloudy due to cataract. The IOL prolonged stay in the eyeball causes the creation of different changes on the surface and inside the implant mainly in form of small-size local defects such as vacuoles and calcium deposites. Their presence worsens the imaging properties of the eye mainly due to occurence of scattered light thus deteriorating the vision quality of patients after cataract surgery. It is very difficult to study influence the effects of these changes on image quality in real patients. To avoid these difficulties two other possibilities were chosen: the analysis of the image obtained in an optomechanical eye model with artificially aged IOL as well as numerical calculation of the image characteristics while the eye lens is burdened with adequately modeled defects. In experiments the optomechanical model of an eye consisting of a glass "cornea", chamber filled with liquid where the IOL under investigation was inserted and a high resulution CCC detector serving as a "retina" was used. The Modulation Transfer Function (MTF) of such "eye" was evaluated on the basis of image of an edge. Experiments show that there is significant connection between ageing defects and decrease in MTF parameters. Numerical part was performed with a computer programme for optical imaging analysis (OpticStudio Professional, Zemax Professional from Radiant Zemax, LLC). On the basis of Atchison eye model with lens burdened with defects Modulation Transfer Functio was calculated. Particular parameters of defects used in a numerical model were based on own measurements. Numerical simulation also show significant connection between ageing defects and decrease of MTF parameters. With this technique the influence of types, density and distribution of local defect in the IOL on the retinal image quality can be evaluated quickly without the need of performing very difficult and even dangereous experiments on real human patients.

  7. Cataract and keratoconus: minimizing complications in intraocular lens calculations.

    PubMed

    Bozorg, Sara; Pineda, Roberto

    2014-01-01

    Patients with both cataract and keratoconus present unique challenges for the surgeon. Accurate keratometry (K) and axial length (AL) readings may be impossible, and uncertainty is introduced when estimating the corneal power for intraocular lens (IOL) selection. Different options on how to choose an IOL and how to manage irregular astigmatism of a keratoconic patient with cataract have been proposed and are reviewed. The stage of keratoconus and the history of the patient are both critical in determining the strategy used in treatment of cataracts.

  8. [Multifocal intraocular lenses. A review].

    PubMed

    Auffarth, G U; Dick, H B

    2001-02-01

    Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of that time MIOL decentration and surgically induced astigmatism were possible complications. In addition reduced contrast sensitivity and increased glare were common problems of MIOL because of their optical principles. New developments in this field in recent years such as the multizonal, progressive refractive MIOL in combination with improved surgical techniques have overcome those initial problems. Therefore, modern multifocal IOLs can be considered not only for correction of aphakia but also for refractive purposes.

  9. Voltage-controlled IPMC actuators for accommodating intra-ocular lens systems

    NASA Astrophysics Data System (ADS)

    Horiuchi, Tetsuya; Mihashi, Toshifumi; Fujikado, Takashi; Oshika, Tetsuro; Asaka, Kinji

    2017-04-01

    An ion polymer-metal composite (IPMC) actuator has unique performance characteristics that were applied in this study for use within the eye. Cataracts are a common eye disease causing clouding of the lens. To treat cataracts, surgeons replace clouded lenses with intraocular lenses (IOLs). However, patients who receive this treatment must still wear reading glasses for tasks requiring close-up vision. We suggest a new voltage-controlled accommodating IOL consisting of an IPMC actuator to change the lens’ focus. We examined the relationship between the displacement performance of an IPMC actuator and the accommodating range of the IOL using in vitro experiments. We show that this system has an accommodating range of approximately 1.15 D under an applied voltage of ±1.2 V. By Lagrange interpolation, we estimate that with an IPMC actuator displacement of 0.14 mm, we can achieve a refractive power of 4 D, which is equivalent to the accommodating range of a 40 year old person.

  10. Long-Lived Flexible Displays Employing Efficient and Stable Inverted Organic Light-Emitting Diodes.

    PubMed

    Fukagawa, Hirohiko; Sasaki, Tsubasa; Tsuzuki, Toshimitsu; Nakajima, Yoshiki; Takei, Tatsuya; Motomura, Genichi; Hasegawa, Munehiro; Morii, Katsuyuki; Shimizu, Takahisa

    2018-05-29

    Although organic light-emitting diodes (OLEDs) are promising for use in applications such as in flexible displays, reports of long-lived flexible OLED-based devices are limited due to the poor environmental stability of OLEDs. Flexible substrates such as plastic allow ambient oxygen and moisture to permeate into devices, which degrades the alkali metals used for the electron-injection layer in conventional OLEDs (cOLEDs). Here, the fabrication of a long-lived flexible display is reported using efficient and stable inverted OLEDs (iOLEDs), in which electrons can be effectively injected without the use of alkali metals. The flexible display employing iOLEDs can emit light for over 1 year with simplified encapsulation, whereas a flexible display employing cOLEDs exhibits almost no luminescence after only 21 d with the same encapsulation. These results demonstrate the great potential of iOLEDs to replace cOLEDs employing alkali metals for use in a wide variety of flexible organic optoelectronic devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Axial movement of the dual-optic accommodating intraocular lens for the correction of the presbyopia: optical performance and clinical outcomes.

    PubMed

    Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane

    2015-01-01

    Presbyopia occurs in the aging eye due to changes in the ciliary muscle, zonular fibers, crystalline lens, and an increased lens sclerosis. As a consequence, the capacity of accommodation decreases, which hampers to focus near objects. With the aim of restoring near vision, different devices that produce multiple focuses have been developed and introduced. However, these devices are still unable to restore accommodation. In order to achieve that goal, dual-optic accommodating Intraocular Lenses have been designed, whose anterior optic displaces axially to increase ocular power, and focus near objects. Although dual-optic accommodating IOLs are relatively new, their outcomes are promising, as they provide large amplitudes of accommodation and a greater IOL displacement than single-optic accommodating IOLs. The outcomes show comfortable near vision, higher patients' satisfaction rates, and minimal postoperative complications like Posterior Capsular Opacification and Anterior Capsular Opacification, due to their design and material. Copyright © 2014. Published by Elsevier Espana.

  12. A clinical study to evaluate the results after toric intraocular lens implantation in cases of corneal astigmatism.

    PubMed

    Moulick, P S; Mohindra, V K; Gurunadh, V S; Patel, Parth; Gupta, Sandeep; Khan, M A

    2018-04-01

    Modern day cataract surgery aims at a spectacle free vision which becomes difficult in cases with pre-operative astigmatism more than 1.5 D. Implantation of toric intra-ocular lenses (IOL) after phacoemulsification in such eyes is one of the ways to counteract this problem. Thirty eyes with pre-operative astigmatism between 1.5 D and 4.5 D were implanted with toric IOLs following uneventful phaco-emulsification. The estimation of the axis of implantation of this toric IOL included calculating the surgically induced astigmatism (SIA) of the surgeon. Post-operatively, 20 (66.67%) patients had a visual acuity 6/9 or better and 17 (57%) had a visual acuity of 6/6 at 12 weeks. The mean postoperative uncorrected visual acuity (UCVA) was 0.12 ± 0.15 at 12 weeks. The difference between means of preoperative best corrected visual acuity (BCVA) LogMAR and postoperative UCVA at 12 wk LogMAR was found to be statistically significant at p  = 0.001. Mean (SD) scores of pre-op astigmatism of study group was -2.20 (0.67) and residual astigmatism was -0.32 (0.44). The difference between means of pre-op astigmatism and residual astigmatism in the study group was significant at p  = 0.001 with 95% CI -2.22 to -1.50. This significant difference was because of the toric IOL implantation.

  13. TiO2 nanoparticles for enhancing the refractive index of hydrogels for ophthalmological applications

    NASA Astrophysics Data System (ADS)

    Hampp, Norbert; Dams, Christian; Badur, Thorben; Reinhardt, Hendrik

    2017-02-01

    Intraocular lenses (IOL) are currently the only treatment for cataract dependent vision impairment and blindness [1]. A polymer suitable for IOL manufacture needs to meet a plurality of properties, biocompatibility, excellent transmission in the visible range, a high flexibility for micro invasive surgery, a high refractive index as well as a good ABBE-number, just to mention the most important ones [2]. We present the use of in situ generated TiO2-nanoparticles to enhance the refractive index of poly-HEMA hydrogels - with are suitable polymers for IOL manufacture[3] - from 1.44 to 1.527 at 589.3 nm combined with an excellent ABBE-number of 54. The nanoparticles were prepared using titaniumdiisopropoxide- bis(acetylacetonate) as a precursor. First the titanium salt was diffused into the poly-HEMA matrix and then it was transformed into TiO2 in boiling water. The resulting pHEMA [TiO2] hydrogel was dried for 10 days under ambient conditions. By lathing these polymers were machined into lens precursors, the so-called Saturn-rings. After reswelling in physiological saline solutions flexible polymer lenses with high surface quality, shape memory and superior optical properties were obtained. The crystal structure of the formed TiO2 nanoparticles was identified as anatase via Xray. No release of titanium ions or TiO2 nanoparticles was observe under physiological conditions. Such hybrid materials of TiO2 nanoparticles and poly-HEMA like hydrogels are promising materials for IOL.

  14. Antifouling foldable acrylic IOLs loaded with norfloxacin by aqueous soaking and by supercritical carbon dioxide technology.

    PubMed

    González-Chomón, Clara; Braga, Mara E M; de Sousa, Herminio C; Concheiro, Angel; Alvarez-Lorenzo, Carmen

    2012-10-01

    Cataracts treatment usually involves the extraction of the opaque crystalline lens and its replacement by an intraocular lens (IOL). A serious complication is the occurrence of endophthalmitis, a post-surgery infection mainly caused by Staphylococcus epidermidis, Staphylococcus aureus, and Pseudomonas aeruginosa. IOLs having the ability to load and to release norfloxacin in a controlled way and at efficient therapeutic levels may help to overcome these issues. In this work, acrylic hydrogels combining 2-hydroxyethyl methacrylate (HEMA) and 2-butoxyethyl methacrylate (BEM) at various ratios were prepared to attain biocompatible networks that can be foldable even in the dry state and thus insertable through minor ocular incision, and that load therapeutic amounts of norfloxacin. Acrylamide (AAm) and methacrylic acid (MAAc) were also incorporated as functional comonomers in small proportions. Water sorption, contact angle, protein adsorption, and optical properties of the networks were characterized. BEM notably decreased the T(g) of the networks, but also the loading by immersion in aqueous solution (presoaking). Then, a scCO(2)-based impregnation/deposition (SSI) method was implemented to improve the uptake of the drug. Loading capacities were discussed in terms of the comonomers composition and the employed method and operational conditions. The networks prepared with HEMA/BEM 20:80 vol/vol and processed with supercritical fluids combine adequate mechanical properties, biocompatibility and norfloxacin loading/release, and seem to be suitable for developing norfloxacin-eluting IOLs. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Cataract blindness in Turkmenistan: results of a national survey

    PubMed Central

    Amansakhatov, S; Volokhovskaya, Z P; Afanasyeva, A N; Limburg, H

    2002-01-01

    Aim: To present results of a rapid assessment of cataract in Turkmenistan. Methods: 6120 eligible people of 50 years and older were selected by systematic random sampling from the whole of Turkmenistan. A total of 6011 people were examined (coverage 98.2%). Results: Cataract is the major cause of bilateral blindness (54%), followed by glaucoma (25%). The age and sex adjusted prevalence of bilateral cataract blindness (VA <3/60) in people of 50 years and older was 0.6% (95% CI: 0.4 to 0.9), with a cataract surgical coverage of 75% (people). For VA <6/60 the prevalence was 2.6% (95% CI: 2.1 to 3.2) in people aged 50 and above, approximately 0.26% of the total population. In this last group the surgical coverage was 44% (people) and 32% (eyes). Of the patients operated with IOL implantation 8.2% could not see 6/60, 44.8% of those operated without IOL could not see 6/60. The main barrier to cataract surgery was indifference (“old age, no need for surgery”), followed by “waiting for maturity.” Conclusion: To increase the cataract surgical coverage in Turkmenistan the intake criteria should be lowered to VA <6/60 or less. At the same time the visual outcome of surgery can be improved by expanding the number of IOL surgeries and routine monitoring of cataract outcome. Additional investments will be required to provide all eye surgeons with appropriate equipment and skills for IOL surgery. PMID:12386068

  16. In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs

    PubMed Central

    Tolosa, Angel; de Fez, Dolores; Caballero, María T.; Miret, Juan J.

    2017-01-01

    Purpose To analyze the “in vitro” aberrometric pattern of a refractive IOL and two extended depth of focus IOLs. Methods A special optical bench with a Shack-Hartmann wavefront sensor (SH) was designed for the measurement. Three presbyopia correction IOLs were analyzed: Mini WELL (MW), TECNIS Symfony ZXR00 (SYM), and Lentis Mplus X LS-313 MF30 (MP). Three different pupil sizes were used for the comparison: 3, 4, and 4.7 mm. Results MW generated negative primary and positive secondary spherical aberrations (SA) for the apertures of 3 mm (−0.13 and +0.12 μm), 4 mm (−0.12 and +0.08 μm), and 4.7 mm (−0.11 and +0.08 μm), while the SYM only generated negative primary SA for 4 and 4.7 mm apertures (−0.12 μm and −0.20 μm, resp.). The MP induced coma and trefoil for all pupils and showed significant HOAs for apertures of 4 and 4.7 mm. Conclusions In an optical bench, the MW induces negative primary and positive secondary SA for all pupils. The SYM aberrations seem to be pupil dependent; it does not produce negative primary SA for 3 mm but increases for higher pupils. Meanwhile, the HOAs for the MW and SYM were not significant. The MP showed in all cases the highest HOAs. PMID:29318040

  17. In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs.

    PubMed

    Camps, Vicente J; Tolosa, Angel; Piñero, David P; de Fez, Dolores; Caballero, María T; Miret, Juan J

    2017-01-01

    To analyze the "in vitro" aberrometric pattern of a refractive IOL and two extended depth of focus IOLs. A special optical bench with a Shack-Hartmann wavefront sensor (SH) was designed for the measurement. Three presbyopia correction IOLs were analyzed: Mini WELL (MW), TECNIS Symfony ZXR00 (SYM), and Lentis Mplus X LS-313 MF30 (MP). Three different pupil sizes were used for the comparison: 3, 4, and 4.7 mm. MW generated negative primary and positive secondary spherical aberrations (SA) for the apertures of 3 mm (-0.13 and +0.12  μ m), 4 mm (-0.12 and +0.08  μ m), and 4.7 mm (-0.11 and +0.08  μ m), while the SYM only generated negative primary SA for 4 and 4.7 mm apertures (-0.12  μ m and -0.20  μ m, resp.). The MP induced coma and trefoil for all pupils and showed significant HOAs for apertures of 4 and 4.7 mm. In an optical bench, the MW induces negative primary and positive secondary SA for all pupils. The SYM aberrations seem to be pupil dependent; it does not produce negative primary SA for 3 mm but increases for higher pupils. Meanwhile, the HOAs for the MW and SYM were not significant. The MP showed in all cases the highest HOAs.

  18. Corneal edema and permanent blue discoloration of a silicone intraocular lens by methylene blue.

    PubMed

    Stevens, Scott; Werner, Liliana; Mamalis, Nick

    2007-01-01

    To report a silicone intraocular lens (IOL) stained blue by inadvertent intraoperative use of methylene blue instead of trypan blue and the results of experimental staining of various lens materials with different concentrations of the same dye. A "blue dye" was used to enhance visualization during capsulorhexis in a patient undergoing phacoemulsification with implantation of a three-piece silicone lens. Postoperatively, the patient presented with corneal edema and a discolored IOL. Various IOL materials were experimentally stained using methylene blue. Sixteen lenses (4 silicone, 4 hydrophobic acrylic, 4 hydrophilic acrylic, and 4 polymethylmethacrylate) were immersed in 0.5 mL of methylene blue at concentrations of 1%, 0.1%, 0.01%, and 0.001%. These lenses were grossly and microscopically evaluated for discoloration 6 and 24 hours after immersion. The corneal edema resolved within 1 month after the initial surgical procedure. After explantation, gross and microscopic analyses of the explanted silicone lens revealed that its surface and internal substance had been permanently stained blue. In the experimental study, all of the lenses except the polymethylmethacrylate lenses were permanently stained by methylene blue. The hydrophilic acrylic lenses showed the most intense blue staining in all dye concentrations. This is the first clinicopathological report of IOL discoloration due to intraocular use of methylene blue. This and other tissue dyes may be commonly found among surgical supplies in the operating room and due diligence is necessary to avoid mistaking these dyes for those commonly used during ocular surgery.

  19. The Correlation between Angle Kappa and Ocular Biometry in Koreans

    PubMed Central

    Choi, Se Rang

    2013-01-01

    Purpose To investigate normative angle kappa data and to examine whether correlations exist between angle kappa and ocular biometric measurements (e.g., refractive error, axial length) and demographic features in Koreans. Methods Data from 436 eyes (213 males and 223 females) were analyzed in this study. The angle kappa was measured using Orbscan II. We used ocular biometric measurements, including refractive spherical equivalent, interpupillary distance and axial length, to investigate the correlations between angle kappa and ocular biometry. The IOL Master ver. 5.02 was used to obtain axial length. Results The mean patient age was 57.5 ± 12.0 years in males and 59.4 ± 12.4 years in females (p = 0.11). Angle kappa averaged 4.70 ± 2.70 degrees in men and 4.89 ± 2.14 degrees in women (p = 0.48). Axial length and spherical equivalent were correlated with angle kappa (r = -0.342 and r = 0.197, respectively). The correlation between axial length and spherical equivalent had a negative correlation (r = -0.540, p < 0.001). Conclusions Angle kappa increased with spherical equivalent and age. Thus, careful manipulation should be considered in older and hyperopic patients when planning refractive or strabismus surgery. PMID:24311927

  20. Glaucoma-related adverse events in the first five years after unilateral cataract removal in the Infant Aphakia Treatment Study

    PubMed Central

    Freedman, Sharon F.; Lynn, Michael J.; Beck, Allen D.; Bothun, Erick D.; Orge, Faruk H.; Lambert, Scott R.

    2015-01-01

    Importance Glaucoma-related adverse events constitute major sight-threatening complications of cataract removal in infancy, yet their relationship to aphakia versus primary intraocular lens (IOL) implantation remains unsettled. Objective To identify and characterize cases of glaucoma and glaucoma-related adverse events (glaucoma+glaucoma suspect) among children in the Infant Aphakia Treatment Study (IATS) by the age of five years. Design, Setting, and Participants A multicenter randomized controlled trial of 114 infants with unilateral congenital cataract who were between age 1–6 months at surgery. Interventions Participants were randomized at cataract surgery to either primary IOL, or no IOL implantation (contact lens [CL]). Standardized definitions of glaucoma and glaucoma suspect were created for IATS and applied for surveillance and diagnosis. Main Outcome Measures Development of glaucoma and glaucoma+glaucoma suspect in operated eyes up to age five years, plus intraocular pressure, visual acuity, and axial length at age five years. Results Product limit estimates of the risk of glaucoma and glaucoma+glaucoma suspect at 4.8 years after surgery were 17% (95%CI=11%–25%) and 31% (95%CI=24%–41%), respectively. The CL and IOL groups were not significantly different for either outcome: glaucoma (hazard ratio(HR)=0.8[95%CI=0.3–2.0],p=0.62); glaucoma+glaucoma suspect: (HR=1.3[95%CI=0.6–2.5],p=0.58). Younger (versus older) age at surgery conferred increased risk of glaucoma (26% versus 9%, respectively at 4.8 years after surgery (HR=3.2[95%CI=1.2–8.3]), and smaller (versus larger) corneal diameter showed increased risk for glaucoma+glaucoma suspect (HR=2.5[95%CI=1.3–5.0]). Age and corneal diameter were significantly positively correlated. Glaucoma was predominantly open angle (19/20 cases, 95%), most eyes received medication (19/20, 95%), and 8/20 (40%) eyes had surgery. Conclusions and Relevance These results suggest that glaucoma-related adverse events are common and increase between one and five years in infants after unilateral cataract removal at 1–6 months of age; primary IOL placement does not mitigate their risk, but surgery at a younger age increases the risk. Longer follow-up of these children may further characterize risk factors, long-term outcomes, potential differences between eyes having primary IOL vs. aphakia, and optimal timing of unilateral congenital cataract removal. PMID:25996491

  1. [Studies on clinical pathophysiology of pseudophakic/aphakic eyes--a journey of 4 decades].

    PubMed

    Miyake, Kensaku

    2008-03-01

    My prime years as an ophthalmologist began as intraocular lenses (IOLs) were just entering into the developmental stage, and I took on as my mission to contribute to perfecting safe and reproducible cataract/IOL implantation surgery. Identifying surgical and/or IOL-related complications consumed time; however, these complications soon became predictable and even preventable with the use of sensitive biological parameters and preclinical evaluation. This was a simple goal for me to pursue my studies on cataract/IOL implantation surgery. I discuss in this review article, based on my previous research, clinico-pathophysiological problems of these intra- and postoperative eyes. The early phase of cataract/IOL implantation surgery development began with a debate as to which is physiologically superior: intracapsular cataract extraction (ICCE) or extracapsular cataract extraction (ECCE). From the perspective of transporting substances from intraocular fluids to extraocular space, which we studied using a nonphysiological substance, fluorescein, ECCE was confirmed to be physiologically superior to ICCE. The transport mechanism of both physiological and nonphysiological substances from intraocular fluids (such as vitreous and aqueous humor) is believed to be related to the pathogenesis of various ocular disorders. Following the fluorescein study, I next focused my attention on biosynthesis and active transport of prostaglandin (PG), which are inflammatory mediators. My studies revealed that PG were more likely to accumulate in ICCE eyes than in ECCE eyes; higher intraocular concentration of PG was also confirmed in eyes with persistent aphakic or pseudophakic cystoid macular edema (CME). While conducting the above studies and having made some observations, I postulated another hypothesis on the pathogenesis of aphakic or pseudophakic CME as follows: topical application of nonsteroidal antiinflammatory drugs (NSAIDs) to eyes with PG, which are biosynthesized intra- and postoperatively during the healing process of uveal tissues and lens epithelial cells, prevents CME. Based on this hypothesis experimental studies were then started, and in 1977 I became the first in the world to prove that topical application of indomethacin, one of the NSAIDs, controls the incidence of CME in ICCE eyes. Thereafter, some 40 follow-up studies have been conducted worldwide, and recent meta-analysis has established the efficacy of indomethacin. Macular edema and CME are recently of significant interest as complications in various ocular disorders. Compared to other forms of CME, the pathophysiology of CME associated with aphakic/ pseudophakic eyes is relatively simple, its natural history is well understood and its reproducibility is high. It is possible that the other forms of macular edema or CME having more complicated pathogenesis may be interpreted by understanding the formation mechanism of aphakia/pseudophakic CME. Our studies have shown how chemical mediators (PG) are systematically involved in the development of aphakic/pseudophakic CME, and that they concurrently cause blood-aqueous barrier disruption and CME, decrease oscillatory potential of the full field ERG, and decrease choroidal blood flow at an early postoperative period, and this has recently been proven. All these phenomena, however, can be effectively prevented by topical application of NSAIDs. I believe these findings provide significant information when considering the pathogenesis and treatment of CME associated with other ocular disorders. Using the primitive method of an early phase, I discovered that anti-PG eye drops can treat disrupted blood-aqueous barrier, and confirmed that the blood-aqueous barrier function is indeed a very sensitive function. I next applied fluorophotometry and laser flaremetry. Using blood-aqueous barrier function as a parameter, the following were evaluated: consensual reaction of blood-aqueous barrier disruption, method of IOL fixation, racial differences in disruption of the aqueous barrier function, drugs used perioperatively, biocompatibility of IOL materials, and effects of preservative agents. Research on preservative agents disclosed that the preservative agent in anti-glaucoma drops more strong by induced pseudophakic CME than the anti-glaucoma agent itself. Thus, this introduced a new concept called Our desire to closely observe the endosurface of the iris, ciliary processes and anterior vitreous face, all of which are closely related to phacoemulsification techniques, posterior chamber lens fixation, and active transport of PG, led me to the development of "Posterior video technique" (Miyake-Apple View). The technique since then has been used to evaluate cataract surgical techniques, to analyze complications, to review IOL designs and fixation techniques, to pre-clinically evaluate surgical devices, and to study variations of local anatomy related to cataract/IOL surgery. The method is also useful as an educational as well as a presentational tool, and it has now been accepted world-wide. The pathogenesis of aphakic/pseudophakic CME, physiological evaluation centering on blood-aqueous barrier function, and preclinical evaluation using the Posterior video technique have all played a significant role in establishing today's safe cataract/IOL implantation surgery.

  2. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    PubMed

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  3. Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function.

    PubMed

    Hayashi, Ken; Hirata, Akira; Yoshida, Motoaki; Yoshimura, Koichi; Hayashi, Hideyuki

    2012-08-01

    To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. Case-control study. Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Subjective Visual Performance and Objective Optical Quality With Intraocular Lens Glistening and Surface Light Scattering.

    PubMed

    Luo, Furong; Bao, Xuan; Qin, Yingyan; Hou, Min; Wu, Mingxing

    2018-06-01

    To evaluate the long-term effect of glistenings and surface light scattering of intraocular lenses (IOLs) on visual and optical performance after cataract surgery. Pseudophakic eyes that underwent standard phacoemulsification and two types of hydrophobic acrylic spherical IOL implantation without complications for at least 5 years were included in this retrospective study. Participants were divided into the glistenings, surface light scattering, and control groups according to the current condition of the IOLs. Then participants received a follow-up examination including uncorrected and corrected distance visual acuity (UDVA and CDVA), contrast sensitivity, straylight, and intraocular higher order aberrations, as well as point spread function (PSF) and modulation transfer function (MTF). A total of 140 eyes were included in the study. UDVA, CDVA, and glare sensitivity were not significantly different among the three groups (P > .05). However, compared with the control group, the IOLs of the glistenings and surface light scattering groups were associated with significantly lower contrast sensitivity under no glare conditions. Furthermore, eye with glistenings exhibited the highest straylight value (P < .05), whereas no difference was found between the surface light scattering and control groups. In contrast to the control group, the spherical aberration increased and the mean values of PSF and MTF decreased in the glistenings and surface light scattering groups. Both glistenings and surface light scattering tend to impair subjective visual performance, such as contrast sensitivity, and potentially affect objective optical quality, including straylight, spherical aberration, PSF, and MTF. [J Refract Surg. 2018;34(6):372-378.]. Copyright 2018, SLACK Incorporated.

  5. High-refractive index polyacrylates based on quinolinone-structures for intraocular lenses

    NASA Astrophysics Data System (ADS)

    Dams, Christian; Helmstetter, Simon; Hampp, Norbert

    2017-02-01

    Intraocular lenses (IOL) have experienced an expanding application over the last decades. Not only they can be used to cure cataract caused blindness, but they are also appointed to ease visual impairments (e.g. -18 - 10 dioptre or astigmatism).[1] These phake IOL require materials with very high refractive indices due to the limited space at the implanting position in the eye of the patient. This enables less invasive operations and such with smaller incisions.[2] Quinolinone derivates, like carbostyril, are currently known from drug design and as a main structural component of several antibiotics.[3] Although they show high refractive indices and good dispersions they have not yet been used in materials for ophthalmic applications. We synthesized and characterized novel high refractive index polymers containing quinolinones as the main refractive unit of the structure.[4] We showed that it was possible to build quinolinone polymers with high refractive indices up to 1.685 at 589 nm. Using this material it would theoretically be possible to reduce the lens thickness of an IOL to under 40 percent compared to a commercial hydrogel lens with a refractive index of 1.470. We also used the synthesized quinolinone acrylates to create hydrophobic copolymers with improved physical properties and high transmission in the visible spectral range. Besides the good lightfastness these copolymers also showed very low tendencies of glistening. In conclusion quinolinones show attractive performances for the usage as a component in acrylic copolymers. If the requirements for IOL keep rising in the coming years these monomers could be used to boost the refractive index of ophthalmic polymer compositions.

  6. [Characteristics of induced labors at Marqués de Valdecilla University Hospital].

    PubMed

    González-Maestro, Marta; Laurrieta-Saiz, Izaskun; García-González, Casandra; López-Mirones, Marta; Terán-Muñoz, Oihane; Alonso-Salcines, Alicia

    2017-01-03

    Induction of labor (IOL) is a common obstetric practice which has increased in recent decades. The main objective of this study is to describe the characteristics of induced labor at Marqués de Valdecilla University Hospital. A descriptive, retrospective study was performed between January 1st and April 30t h of 2014, by reviewing medical histories. A standardised registration has been used to collect data. There were a total of 376 IOL, the incidence was 35.1%. The most frequent indications were premature rupture of membranes (33.9%) and gestational age of 41 completed weeks or more (16.7%). Oxytocin was used to start 66.8% of the IOL. Of all births, 61.4% were spontaneous vaginal births and 25.3% caesarean sections. An increase in the rate of caesarean sections was observed in the group of gestational age of 41 completed weeks or more (27.3%) and hypertensive disorders of pregnancy (29.8%). The main cause of dystocia was suspected fetal compromise (36.4%). Adaptation to extrauterine life was within the parameters of normality in 94% of the newborn infants. Comparing the IOL with spontaneous labor, a decrease in spontaneous vaginal births and an increase in caesarean sections and operative vaginal births was observed in the inductions. This study provides relevant information to the professionals in the fields of gynaecology and obstetrics, and opens the way for future research to obtain results transferable to the clinical practice. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  7. Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.

    PubMed

    Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo

    2015-05-01

    Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.

  8. Visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens: A prospective study

    PubMed Central

    Sachdev, Gitansha Shreyas; Ramamurthy, Shreyas; Sharma, Umesh; Dandapani, Ramamurthy

    2018-01-01

    Purpose: The aim of this study was to analyze the objective and subjective visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens (EROV IOL), the Tecnis Symfony. Methods: This was a prospective interventional case series conducted at a tertiary eye care hospital in South India. The study included patients with bilateral implantation of EROV IOLs. The uncorrected and corrected visual acuity for distance, intermediate, and near vision was recorded at 6 weeks and 6 months’ postoperative visit. A subjective questionnaire was administered to assess spectacle independence, photic phenomenon, and overall satisfaction. All data were recorded using Microsoft Excel worksheet. The analyses were performed using SPSS for windows software. Results: Our study included fifty patients with bilateral implantation of EROV IOLs. The mean age was 59.84 ± 11.68 years. The mean uncorrected binocular distance, intermediate, and near visual acuity (in standard decimal equivalent) was 0.89,0.99 and 0.99 respectively, at 6 months’ postoperative visit. Ninety-six percent of the patients did not require spectacles for distance and 98% of the patients were free from spectacles for intermediate and near vision. 94% of our patients perceived no or minimal photic phenomena such as glare and halos. The mean subjective patient satisfaction score (out of 10) for distance, intermediate, and near was 9, 10, and 9, respectively. Conclusion: The EROV IOLs demonstrated high levels of spectacle independence for distance, intermediate, and near vision. The incidence of photic phenomena observed was minimal with a high level of patient satisfaction. PMID:29480252

  9. Exploring the optimum step size for defocus curves.

    PubMed

    Wolffsohn, James S; Jinabhai, Amit N; Kingsnorth, Alec; Sheppard, Amy L; Naroo, Shehzad A; Shah, Sunil; Buckhurst, Phillip; Hall, Lee A; Young, Graeme

    2013-06-01

    To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified. Midland Eye, Solihull, United Kingdom. Evaluation of a technique. Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers). A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05). Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

    PubMed

    García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián

    2018-01-01

    To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

  11. The effect of single-piece hydrophobic acrylic intraocular lenses on the development of posterior capsule opacification.

    PubMed

    Praveen, Mamidipudi R; Shah, Gauri D; Vasavada, Abhay R; Dave, Khyati H

    2015-09-01

    To evaluate the long-term effect of a single-piece hydrophobic acrylic intraocular lens (IOL), AcrySof SN60AT (Alcon Laboratories, Fort Worth, Texas, USA), on the development of posterior capsule opacification (PCO) 5 years postoperatively. Prospective, observational, consecutive, case series. setting: Iladevi Cataract and IOL Research Center, Ahmedabad, India. Three hundred and ninety eyes with uncomplicated age-related cataract were included. Patients with diabetes mellitus, glaucoma, high myopia, pseudoexfoliation, traumatic cataract, subluxated cataract, previous ocular surgeries, and allergy to dilating drops were excluded. intervention procedures: Digital retroillumination photographic documentation was performed and analyzed for PCO using Evaluation of Posterior Capsule Opacification software. The scores and areas were calculated. PCO development and the influence of the anterior capsule cover (total on and part on) on the IOL optic was studied within the capsulorrhexis margin and the central 3.0 mm optic area. There was a significant increase in PCO up to 3 years. No significant change in PCO was observed between 3 and 5 years within the capsulorrhexis margin and central 3.0 mm optic area. In the total on group, within the capsulorrhexis margin, significantly lower scores and areas were observed when compared with part-on scores and areas. The increase in PCO up to 3 years was significant. Stabilization in PCO was observed between 3 and 5 years with no difference at 5 years. There was a low incidence of PCO in eyes with total anterior capsule cover over the IOL optic. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. The relationship between morphological changes of lens epithelial cells and intraocular lens optic material.

    PubMed

    Majima, K

    1998-01-01

    To examine the morphological changes of lens epithelial cells (LECs) occurring directly beneath and at regions contacting various intraocular lens (IOL) optic materials, human LECs were cultured on human anterior lens capsules and were further incubated upon placing above the cells lens optics made of polymethylmethacrylate, silicone, and soft acrylic material. Observations as to the morphological changes of LECs under phase-contrast microscope and scanning electron microscope were performed on the 14th day of incubation. Gatherings of LECs were observed at regions contacting the soft acrylic material under phase-contrast microscope, and gatherings of LECs were observed accurately at the same regions mentioned above under scanning electron microscope. On the other hand, LECs in contact with two other optic materials did not show morphological changes. The results suggest that LECs attached to and proliferated on not only the anterior lens capsules but also the soft acrylic IOL optics. The model used in this study may be useful in studying the relationship between cellular movement of LECs and IOL optic material.

  13. [Trabeculotomy ab interno combined with extracapsular cataract extraction and IOL implantation].

    PubMed

    Alekseev, B N; Ermolaev, A P

    2003-01-01

    We made a total of 96 surgeries of extracapsular cataract extraction and IOL implantation combined with trabeculotomy ab interno during a period of 7 years. Patients with both open-angle and narrow-angle glaucoma of stages I and II and with the intraocular pressure (IOP) below or equal to 23 mm Hg according to Goldman under the conditions of hypotensive medicamental regimen were selected for surgery. After IOL was implanted into the lens bag, trabeculotomy ab interno was implemented as stage 2. A special mirror, introduced through the cataract incision, was used for direct gonioscopic monitoring. The trabecula was incised by the edge of a curved surgical knife under direct visual control. We regarded bleeding from the opened sinus as a favorable sign indicative of that the intrascleral collectors were intact. Only minor hyphemas were registered as postoperative complications; there was not a single case of ciliary-and-choroidal detachment. IOP was compensated for, in 6 months after surgery, in 94% of patients--69.8% of them did not use any hypotensive drops.

  14. Posterior Capsule Opacification After Phacoemulsification: Annual Review.

    PubMed

    Vasavada, Abhay R; Praveen, Mamidipudi R

    2014-01-01

    The purpose of this article is to provide a clinical update on posterior capsule opacification (PCO) after phacoemulsification by reviewing the literature from the last 12 months. This article is a literature review. The authors conducted a 1-year literature search in the English language on PCO using PubMed. The period used to conduct the literature search was from January 1, 2013, to January 1, 2014. The following search terms were used during the PubMed search: phacoemulsification, microcoaxial incision, posterior capsule opacification, long-term evaluation of intraocular lens (IOL) implantation, IOL edge design and material, surgical technique, anterior capsule overlap on the IOL optic, diabetes mellitus, myopia, pseudoexfoliation, retinitis pigmentosa, uveitis, and neodymium: yttrium-aluminum-garnet laser capsulotomy. This review incorporates original articles that provided fresh insights and updates on PCO. Particular attention was paid to observational, randomized, controlled clinical trials, as well as analyses of larger cohorts with a prospective and retrospective study design. Letters to the editor, unpublished works, experimental trials and abstracts were not considered. This annual review provides a brief update on PCO that might be of interest to the practicing clinical ophthalmologist.

  15. [Design and optical principles of multifocal lenses].

    PubMed

    Auffarth, G U; Rabsilber, T M; Kohnen, T; Holzer, M P

    2008-06-01

    Multifocal intraocular lenses (MIOLs) of different designs have been used for more than 20 years in modern cataract surgery. The first IOLs were either refractive 2-3-zone designs or of diffractive concept. All MIOL types, regardless of manufacturer, show reduced contrast sensitivity and increased glare for years. Nevertheless, even first-generation MIOL patients had very good functional results when patient selection, IOL calculation, and surgical techniques were appropriate. Today's gold standard is foldable, aspherical diffractive, or refractive MIOLS. Advancements in technology allow the possibility that MIOLs will be used for aphakia correction as well as presbyopia correction.

  16. Femtosecond laser–assisted cataract surgery in vitrectomized eye with posterior chamber phakic intraocular lens

    PubMed Central

    Anisimova, Natalia; Malyugin, Boris; Arbisser, Lisa B.; Sobolev, Nikolay

    2017-01-01

    Summary We describe a case of femtosecond laser–assisted cataract surgery (FLACS) in an eye with multiple comorbidities, including retinal detachment surgery, high myopia, posterior chamber phakic intraocular lens (PC pIOL) and residual, emulsified, silicone oil located in the anterior chamber. FLACS was affected by the optical blockage, but the incomplete capsular tear was recoverable. The case suggests that silicone oil bubbles concentrated at the dome of the posterior corneal surface, along with the PC pIOL optic edges and scars after corneal astigmatic relaxing incisions can lead to incomplete anterior capsulotomy. PMID:28924422

  17. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  18. Cataract Blindness in Osun State, Nigeria: Results of a Survey

    PubMed Central

    Kolawole, Olubayo U.; Ashaye, Adeyinka O.; Mahmoud, Abdulraheem O.; Adeoti, Caroline O.

    2012-01-01

    Purpose: To estimate the burden of blindness and visual impairment due to cataract in Egbedore Local Government Area of Osun State, Nigeria. Materials and Methods: Twenty clusters of 60 individuals who were 50 years or older were selected by systematic random sampling from the entire community. A total of 1,183 persons were examined. Results: The age- and sex-adjusted prevalence of bilateral cataract-related blindness (visual acuity (VA) < 3/60) in people of 50 years and older was 2.0% (95% confidence interval (CI): 1.6–2.4%). The Cataract Surgical Coverage (CSC) (persons) was 12.1% and Couching Coverage (persons) was 11.8%. The age- and sex-adjusted prevalence of bilateral operable cataract (VA < 6/60) in people of 50 years and older was 2.7% (95% CI: 2.3–3.1%). In this last group, the cataract intervention (surgery + couching) coverage was 22.2%. The proportion of patients who could not attain 6/60 vision after surgery were 12.5, 87.5, and 92.9%, respectively, for patients who underwent intraocular lens (IOL) implantation, cataract surgery without IOL implantation and those who underwent couching. “Lack of awareness” (30.4%), “no need for surgery” (17.6%), cost (14.6%), fear (10.2%), “waiting for cataract to mature” (8.8%), AND “surgical services not available” (5.8%) were reasons why individuals with operable cataract did not undergo cataract surgery. Conclusions: Over 600 operable cataracts exist in this region of Nigeria. There is an urgent need for an effective, affordable, and accessible cataract outreach program. Sustained efforts have to be made to increase the number of IOL surgeries, by making IOL surgery available locally at an affordable cost, if not completely free. PMID:23248537

  19. Implantation of a customized toric intraocular lens for correction of post-keratoplasty astigmatism

    PubMed Central

    Srinivasan, S; Ting, D S J; Lyall, D A M

    2013-01-01

    Purpose To report visual and refractive outcomes, and endothelial cell loss following primary and secondary ‘piggyback' toric intraocular lens (IOL) implantation in patients with high post-penetrating keratoplasty (PK) astigmatism. Methods Prospective case series. Nine eyes of nine patients with post-PK astigmatism were consecutively recruited for implantation of a customized toric IOL. Six underwent simultaneous phacoemulsification (PE) and three pseudophakic eyes had a secondary ‘piggyback' toric IOL implanted in the ciliary sulcus. Mean follow-up time was 17.2±7.7 months. Pre- and post-operative uncorrected (UDVA) and best-corrected (BDVA) distance visual acuities and refractive errors were collected for comparison. Cartesian astigmatic vectors were calculated to identify a change in the magnitude of astigmatism pre- compared to postoperatively. Pre- and post-operative endothelial cell counts were also collected for analysis. Results UDVA (logMAR) improved from 1.13±0.51 preoperatively to 0.48±0.24 postoperatively (P-value=0.003). There was no significant change in BDVA (P-value=0.905) from 0.31±0.27 to 0.26±0.19. Corneal astigmatism preoperatively was 6.57±4.40 diopters (D). Post-operative refractive cylinder was 0.83±1.09 D compared to 3.89±4.01 D preoperatively (P=0.039). Analysis of astigmatic Cartesian x and y coordinates found a significant reduction postoperatively compared to preoperatively (P=0.005 and P=0.002), respectively. Mean endothelial cell loss was 9.9%. Conclusion: Implantation of a customized primary or secondary ‘piggyback' toric IOL serves as an effective modality in treating patients with high post-PK astigmatism. PMID:23348728

  20. [Evaluation of Postoperative Astigmatism Correction and Postoperative Rotational Stability of Two Toric Intraocular Lenses].

    PubMed

    Grohlich, M; Miháltz, K; Lasta, M; Weingessel, B; Vécsei-Marlovits, V

    2017-06-01

    Background The aim of this retrospective study was to evaluate the rotational stability and the refractive outcome of two different toric IOLs. Methods This study included 41 eyes with corneal astigmatism greater than 1.5 diopters (D). All patients underwent surgery in the Department of Ophthalmology at Hietzing Hospital between 2010 and 2013. The study lenses were the Alcon AcrySof IQ Toric IOL and the Abbott Tecnis Toric Aspheric IOL. Measurements of corneal topography and aberrations were performed with the HOYA iTrace™. Determination of visual acuity was performed with ETDRS charts. Optical aberrations were represented by Zernike coefficients, and optical quality was assessed with the Strehl ratio. Results Mean rotation was 4.92° (standard deviation: ± 4.10°) in the Alcon group and 4.31° (± 4.59°) in the Abbott group. No significant difference was observed between the two toric intraocular lenses. Rotational stability was comparable to results from other studies. Astigmatism correction was visualised with a power-vector analysis, which demonstrated similar results in both lenses and a clear success of astigmatism correction. No statistically significant differences were found in residual refractive astigmatism, which was 0.85 ± 0.48 D in the Alcon group and 1.09 ± 0.66 in the Tecnis group. No significant difference between the two groups was found in the Strehl ratio. Conclusion Implantation of toric intraocular lenses (Alcon + Abbott) in patients with regular astigmatism is an effective and safe method, which should be offered to patients. Both the Tecnis and the AcrySof toric IOLs similarly reduced ocular astigmatism. Georg Thieme Verlag KG Stuttgart · New York.